SAMPLING DEVICE FOR pH MEASUREMENT IN PROCESS STREAMS
Michelson, C.E.; Carson, W.N. Jr.
1958-11-01
A pH cell is presented for monitoring the hydrogen ion concentration of a fluid in a process stream. The cell is made of glass with a side entry arm just above a reservoir in which the ends of a glass electrode and a reference electrode are situated. The glass electrode contains the usual internal solution which is connected to a lead. The reference electrode is formed of saturated calomel having a salt bridge in its bottom portion fabricated of a porous glass to insure low electrolyte flow. A flush tube leads into the cell through which buffer and flush solutions are introduced. A ground wire twists about both electrode ends to insure constant electrical grounding of the sample. The electrode leads are electrically connected to a pH meter of aay standard type.
49 CFR Appendix D to Part 192 - Criteria for Cathodic Protection and Determination of Measurements
Code of Federal Regulations, 2010 CFR
2010-10-01
... half cell: (1) Saturated KCl calomel half cell: −0.78 volt. (2) Silver-silver chloride half cell used...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Pt... cell. Determination of this voltage must be made with the protective current applied, and in accordance...
Ma, Xiang; Chen, Ting; Liu, Lifang; Li, Genxi
2005-06-01
Haemoglobin (Hb) was entrapped in polysorbate 20 and then modified on a pyrolytic graphite electrode. Electrochemical studies revealed that a pair of stable and well-defined redox peaks attributed to the direct redox reaction of Hb could be observed in a phosphate buffer solution (pH 6.0). The anodic and cathodic peaks were located at -236 and -316 mV (versus a saturated calomel reference electrode) separately. The formal potential, E0', was linearly varied with pH in the range from 3.0 to 10.0 with a slope of -48.0 mV.pH-1. Moreover, the protein was capable of catalysing the reduction of H2O2. Accordingly, an unmediated biosensor for H2O2 was prepared with a linear range from 8.0x10(-7) to 1.0x10(-3) M. This biosensor exhibited good stability, sensitivity and reproducibility.
Ultrasound-assisted Micro-emulsion Synthesis of a Highly Active Nano-particle Catalyst
2010-03-01
saturated calomel electrode [SCE]). 15. SUBJECT TERMS Microemulsion synthesis, Nano particles, Catalysts, Ultrasound, Oxygen reduction, Rotating disk...30 40 50 60 ω1/2 (rpm 1/2) i ( m A .c m -2 ) Ultrasound Assisted Microemulsion Microemulsion non- Microemulsion O2 4e Redc by Diff. Figure 17. Levich...2.0 2.4 0 0.02 0.04 0.06 0.08 0.1 0.12 ω-1/2(rpm-1/2) i-1 (m A -1 cm 2 ) non- Microemulsion Microemulsion Ultrasound Assisted Microemulsion O2 4-e Redc
Preparation of cauliflower-like CdS/ZnS/ZnO nanostructure and its photoelectric properties
NASA Astrophysics Data System (ADS)
Liu, Zhifeng; Guo, Keying; Wang, Yun; Zheng, Xuerong; Ya, Jing; Li, Junwei; Han, Li; Liu, Zhichao; Han, Jianhua
2014-06-01
Cauliflower-like CdS/ZnS/ZnO nanostructure is fabricated via a simple hydrothermal method. Factors such as concentration of reaction solution, reaction temperature, as well as reaction time in the synthetic process are investigated, and the working mechanism of the nanostructure is suggested. Hydrogen generation efficiency of 4.69 % at 0.29 V versus saturated calomel electrode is achieved using synthesized nanostructure as electrode due to the improved absorption and appropriate energy gap structure, which is confirmed by enhanced absorption spectrum. The expected products have potential application in photoelectrochemical water splitting.
Simon, Evelyne; Halliwell, Catherine M; Toh, Chee Seng; Cass, Anthony E G; Bartlett, Philip N
2002-01-01
Immobilisation of enzymes is important for applications such as biosensors or biofuel cells. A poly(histidine) tag had been introduced on the C terminus of a lactate dehydrogenase enzyme. This mutant enzyme was then immobilised onto poly(aniline) (PANi)-poly(anion) composite films, PANi-poly(vinylsulfonate) (PVS) or PANi-poly(acrylate) (PAA). The NADH produced by the immobilised enzyme in the presence of beta-nicotinamide adenine dinucleotide (NAD(+)) and lactate is oxidised at the poly(aniline)-coated electrode at 0.05 to 0.1 V vs. saturated calomel electrode (SCE) at 35 degrees C.
Pulse-voltammetric glucose detection at gold junction electrodes.
Rassaei, Liza; Marken, Frank
2010-09-01
A novel glucose sensing concept based on the localized change or "modulation" in pH within a symmetric gold-gold junction electrode is proposed. A paired gold-gold junction electrode (average gap size ca. 500 nm) is prepared by simultaneous bipotentiostatic electrodeposition of gold onto two closely spaced platinum disk electrodes. For glucose detection in neutral aqueous solution, the potential of the "pH-modulator" electrode is set to -1.5 V vs saturated calomel reference electrode (SCE) to locally increase the pH, and simultaneously, either cyclic voltammetry or square wave voltammetry experiments are conducted at the sensor electrode. A considerable improvement in the sensor electrode response is observed when a normal pulse voltammetry sequence is applied to the modulator electrode (to generate "hydroxide pulses") and the glucose sensor electrode is operated with fixed bias at +0.5 V vs SCE (to eliminate capacitive charging currents). Preliminary data suggest good linearity for the glucose response in the medically relevant 1-10 mM concentration range (corresponding to 0.18-1.8 g L(-1)). Future electroanalytical applications of multidimensional pulse voltammetry in junction electrodes are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kotteswaran, S.; Pandian, M. Senthil; Ramasamy, P., E-mail: ramasamyp@ssn.edu.in
2016-05-23
Zn-Porphyrin dye has been synthesized by the reaction between aldehydes and pyrrole. The dye structure was confirmed by {sup 1}H NMR, {sup 13}C NMR spectrum. The functional group of the dye molecule was confirmed by FTIR spectrum. The UV-Vis-NIR absorption spectrum of Zn-Porphyrin in DMF solution was recorded in spectrophotometer. The UV-Vis NIR spectrum of dye exhibits a strong Soret band and Q-band. Cyclic Voltammograms were obtained with three electrode systems: Pt as counter electrode, saturated calomel used as a reference electrode and glassy carbon as working electrode at a scan rate of 100 mV/s. The curves recorded the oxidation ofmore » 0.5 mM compound Zn-Porphyrin in a dichloromethane solution containing 0.1M TBAP as supporting electrolyte, reveal two successive quasi reversible redox couples with the first anodic and cathodic peak potentials of -0.2 V and -1 V. The second anodic and cathodic peak potentials are 0.82 V and 0.01 V respectively.« less
Code of Federal Regulations, 2013 CFR
2013-04-01
... subnitrate, calomel, camphor, cholesterol, ergot fluid extract, hexachlorophene, ichthammol, isobutamben... aminacrine hydrochloride, bismuth subnitrate, calomel, camphor, cholesterol, ergot fluid extract...
Code of Federal Regulations, 2011 CFR
2011-04-01
... subnitrate, calomel, camphor, cholesterol, ergot fluid extract, hexachlorophene, ichthammol, isobutamben... aminacrine hydrochloride, bismuth subnitrate, calomel, camphor, cholesterol, ergot fluid extract...
Code of Federal Regulations, 2010 CFR
2010-04-01
... subnitrate, calomel, camphor, cholesterol, ergot fluid extract, hexachlorophene, ichthammol, isobutamben... aminacrine hydrochloride, bismuth subnitrate, calomel, camphor, cholesterol, ergot fluid extract...
Code of Federal Regulations, 2012 CFR
2012-04-01
... subnitrate, calomel, camphor, cholesterol, ergot fluid extract, hexachlorophene, ichthammol, isobutamben... aminacrine hydrochloride, bismuth subnitrate, calomel, camphor, cholesterol, ergot fluid extract...
Code of Federal Regulations, 2014 CFR
2014-04-01
... subnitrate, calomel, camphor, cholesterol, ergot fluid extract, hexachlorophene, ichthammol, isobutamben... aminacrine hydrochloride, bismuth subnitrate, calomel, camphor, cholesterol, ergot fluid extract...
High frequency reference electrode
Kronberg, J.W.
1994-05-31
A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.
High frequency reference electrode
Kronberg, James W.
1994-01-01
A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.
Degradation pathway of malachite green in a novel dual-tank photoelectrochemical catalytic reactor.
Diao, Zenghui; Li, Mingyu; Zeng, Fanyin; Song, Lin; Qiu, Rongliang
2013-09-15
A novel dual-tank photoelectrochemical catalytic reactor was designed to investigate the degradation pathway of malachite green. A thermally formed TiO₂/Ti thin film electrode was used as photoanode, graphite was used as cathode, and a saturated calomel electrode was employed as the reference electrode in the reactor. In the reactor, the anode and cathode tanks were connected by a cation exchange membrane. Results showed that the decolorization ratio of malachite green in the anode and cathode was 98.5 and 96.5% after 120 min, respectively. Malachite green in the two anode and cathode tanks was oxidized, achieving the bipolar double effect. Malachite green in both the anode and cathode tanks exhibited similar catalytic degradation pathways. The double bond of the malachite green molecule was attacked by strong oxidative hydroxyl radicals, after which the organic compound was degraded by the two pathways into 4,4-bis(dimethylamino) benzophenone, 4-(dimethylamino) benzophenone, 4-(dimethylamino) phenol, and other intermediate products. Eventually, malachite green was degraded into oxalic acid as a small molecular organic acid, which was degraded by processes such as demethylation, deamination, nitration, substitution, addition, and other reactions. Copyright © 2013 Elsevier B.V. All rights reserved.
[Studies on photo-electron-chemical catalytic degradation of the malachite green].
Li, Ming-yu; Diao, Zeng-hui; Song, Lin; Wang, Xin-le; Zhang, Yuan-ming
2010-07-01
A novel two-compartment photo-electro-chemical catalytic reactor was designed. The TiO2/Ti thin film electrode thermally formed was used as photo-anode, and graphite as cathode and a saturated calomel electrode (SCE) as the reference electrode in the reactor. The anode compartment and cathode compartment were connected with the ionic exchange membrane in this reactor. Effects of initial pH, initial concentration of malachite green and connective modes between the anode compartment and cathode compartment on the decolorization efficiency of malachite green were investigated. The degradation dynamics of malachite green was studied. Based on the change of UV-visible light spectrum, the degradation process of malachite green was discussed. The experimental results showed that, during the time of 120 min, the decolouring ratio of the malachite green was 97.7% when initial concentration of malachite green is 30 mg x L(-1) and initial pH is 3.0. The catalytic degradation of malachite green was a pseudo-first order reaction. In the degradation process of malachite green the azo bond cleavage and the conjugated system of malachite green were attacked by hydroxyl radical. Simultaneity, the aromatic ring was oxidized. Finally, malachite green was degraded into other small molecular compounds.
Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis
2015-01-01
Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them.
Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis
2015-01-01
Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05). Corrosion rate of brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them. PMID:26697148
Electrochemical oxidation of 243Am(III) in nitric acid by a terpyridyl-derivatized electrode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dares, C. J.; Lapides, A. M.; Mincher, B. J.
A high surface area, tin-doped indium oxide electrode surface-derivatized with a terpyridine ligand has been applied to the oxidation of trivalent americium to Am(V) and Am(VI) in nitric acid. Potentials as low as 1.8 V vs. the saturated calomel electrode are used, 0.7 V lower than the 2.6 V potential for one-electron oxidation of Am(III) to Am(IV) in 1 M acid. This simple electrochemical procedure provides, for the first time, a method for accessing the higher oxidation states of Am in non-complexing media for developing the coordination chemistries of Am(V) and Am(VI) and, more importantly, for separation of americium frommore » nuclear waste streams.« less
NASA Astrophysics Data System (ADS)
Okamoto, Naoki; Kataoka, Kentaro; Saito, Takeyasu
2017-07-01
A manufacturing method for SnS using a one-step electrochemical technique was developed. The sulfide semiconductor was formed by electrodeposition using an aqueous bath at low temperatures. The sulfide semiconductor particles produced were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The highest current density at which SnS was formed was 1800 mA/cm2 at a bath temperature of 293 K, which is 36 times larger than that in a previous deposition process. Analysis of the chronoamperometric current-time transients indicated that in the potential range from -1100 to -2000 mV vs saturated calomel electrode (SCE), the electrodeposition of SnS can be explained by an instantaneous nucleation model.
Environmental factors affecting corrosion of munitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bundy, K.; Bricka, M.; Morales, A.
1995-12-31
Spent small arms munitions have accumulated for years at outdoor firing ranges operated by the DoD and other groups. Used bullets are often subjected to moisture sources. There is increasing concern that accumulations of lead-based munitions represent potential sources of water and soil pollution. To understand both the severity of and solutions to this problem, it is necessary to measure how rapidly bullets corrode and to determine the soil variables affecting the process. In this study M16 bullets were buried in samples of soil taken from Louisiana army firing ranges. Four environmental conditions were simulated; rain water, acid rain, seamore » water, and 50% sea water/50% acid rain. The three electrode technique was used to measure the bullet corrosion. Graphite rods served as counter electrodes. A saturated calomel reference electrode was used along with a specially constructed salt bridge. Electrochemical measurements were conducted using a computer-controlled potentiostat to determine corrosion potential, soil resistance, and corrosion current. The rate of corrosion was found to markedly increase with decreasing soil pH and increasing chloride and moisture contents, with the chloride content being the most influential variable. High soil resistance and noble corrosion potential were found to be associated with low corrosion rates. This is important since both parameters can be readily measured in the field.« less
NASA Astrophysics Data System (ADS)
Patil, U. M.; Gurav, K. V.; Fulari, V. J.; Lokhande, C. D.; Joo, Oh Shim
Nanostructured nickel hydroxide thin films are synthesized via a simple chemical bath deposition (CBD) method using nickel nitrate Ni(NO 3) 2 as the starting material. The deposition process is based on the thermal decomposition of ammonia-complexed nickel ions at 333 K. The structural, surface morphological, optical, electrical and electrochemical properties of the films are examined. The nanocrystalline "β" phase of Ni(OH) 2 is confirmed by the X-ray diffraction analysis. Scanning electron microscopy reveals a macroporous and interconnected honeycomb-like morphology. Optical absorption studies show that "β-Ni(OH) 2" has a wide optical band-gap of 3.95 eV. The negative temperature coefficient of the electrical resistance of "β-Ni(OH) 2", is attributed to the semiconducting nature of the material. The electrochemical properties of "β-Ni(OH) 2" in KOH electrolyte are examined by cyclic voltammetric (CV) measurements. The scan-rate dependent voltammograms demonstrate pseudocapacitive behaviour when "β-Ni(OH) 2" is employed as a working electrode in a three-electrode electrochemical cell containing 2 M KOH electrolyte with a platinum counter electrode and a saturated calomel reference electrodes. A specific capacitance of ∼398 × 10 3 F kg -1 is obtained.
Justin, Gusphyl A; Sun, Mingui; Zhang, Yingze; Cui, X Tracy; Sclabassi, Robert
2006-01-01
Previous studies by our group have demonstrated the ability of white blood cells to generate small electrical currents, on the order of 1-3 microA/cm(2), when placed at the anode compartment of a proton exchange membrane (PEM) biological fuel cell. In this research study, an electrochemical technique is used to further investigate the electron transfer ability of activated white blood cells at interfacing electrodes in an attempt to elucidate the mechanism of electron transfer in the original biological fuel cell experiments. Cyclic voltammograms were obtained for human white blood cells using a three-electrode system. The working and counter electrodes were made from carbon felt and platinum, respectively, while the reference was a saturated calomel electrode (SCE). Oxidation peaks were observed at an average potential of 363 mV vs. SCE for the PMA/ionomycin activated white blood cells in glucose solution. However a corresponding reduction peak was not observed, suggesting irreversibility of the redox reaction. The cyclic voltammograms recorded for the white blood cells bear very close similarities to those of the neurotransmitter serotonin (5-HT). Serotonin released by white blood cells into the extracellular environment may be irreversibly oxidized at the working electrode in the cyclic voltammetry experiments and at the PEM biological fuel cell anode in our earlier electrochemical cell studies.
NASA Astrophysics Data System (ADS)
Eliyan, Faysal Fayez
2017-09-01
The Scanning Vibrating Electrode Technique (SVET) was used to analyze the anodic reactions inside and around a porous Al2O3 cluster embedded onto an iron foil. The tests were carried out at -0.7 V vs. Saturated Calomel Electrode, in naturally aerated solutions of 0.1, 0.2, 0.35, and 0.5 M bicarbonate concentration. During 10 h of testing, the SVET showed evidence for a formation of a passive film in and around the cluster, in the scanning area shown in the graphical abstract. In the dilute 0.1 and 0.2 M solutions, the passive films formed slower than those in 0.35 and 0.5 M solutions. In the SVET maps, the passive films showed that they could suppress dissolution to currents comparable to those of slower dissolution under the porous Al2O3 cluster.
NASA Astrophysics Data System (ADS)
Singh, Nirupama; Kumar, Pushpendra; Upadhyay, Sumant; Choudhary, Surbhi; Satsangi, Vibha R.; Dass, Sahab; Shrivastav, Rohit
2013-06-01
In the present study Readymade Graphene oxide (GO) has been coated using electrochemical deposition technique [1] on to the conducting glass (ITO) substrate. Raman spectra generated D and G Peaks obtained at 1346 and 1575 cm-1 confirmed the presence of GO [2]. The UV-Visible absorption measurements provided absorption peak at 262 nm and the Tauc plots yielded band-gap energy of sample around 3.9 eV. The PEC measurements involved determination of current-voltage (I-V) characteristics, both under darkness as well as under illumination. The photocurrent of 1.21 mA/cm-2 at 0.5 V applied voltage (vs. saturated calomel electrode), was recorded under the illumination of 150 Wcm-2 (Xenon arc lamp; Oriel, USA). The photocurrent values were utilized further to calculate applied bias photon-to-current efficiency (% ABPE), which was estimated to 0.98 % at 0.5 V bias.
Mao, Xu; Zhang, Jia-Ning; Gao, Li-Hua; Su, Yu; Chen, Peng-Xia; Wang, Ke-Zhi
2016-04-01
An electrostatically self-assembled multilayer thin film consisting of alternating layers of Keggin polyoxometalate of Zn-substituted tungstoborate (BW11Zn) and Rhodamine B (RhB) has successfully been prepared on a quartz and indium-tin oxide (ITO) glass substrate. The ultraviolet-visible (UV-vis) absorption spectra demonstrated that the electrostatically self-assembled film of (BW11Zn/RhB)n was uniformly deposited layer by layer, and the RhB molecules in the film formed the J-aggregation. The photoelectrochemical investigations showed that the films generated stable cathodic photocurrents that originated from RhB, and the maximal cathodic photocurrent density generated by an eight-layer film was 4.9 µA/cm2 while the film was irradiated with 100 mW/cm2 polychromatic light of 730 nm > λ > 325 nm at an applied potential of 0 V versus a saturated calomel electrode.
Xia, Xue; Sun, Yanmei; Liang, Peng; Huang, Xia
2012-09-01
The long-term effect of set potential on oxygen reducing biocathodes was investigated in terms of electrochemical and biological characteristics. Three biocathodes were poised at 200, 60 and -100 mV vs. saturated calomel electrode (SCE) for 110 days, including the first 17 days for startup. Electrochemical analyses showed that 60 mV was the optimum potential during long-term operation. The performance of all the biocathodes kept increasing after startup, suggesting a period longer than startup time needed to make potential regulation more effective. The inherent characteristics without oxygen transfer limitation were studied. Different from short-term regulation, the amounts of biomass were similar while the specific electrochemical activity was significantly influenced by potential. Moreover, potential showed a strong selection for cathode bacteria. Clones 98% similar with an uncultured Bacteroidetes bacterium clone CG84 accounted for 75% to 80% of the sequences on the biocathodes that showed higher electrochemical activity (60 and -100 mV). Copyright © 2012 Elsevier Ltd. All rights reserved.
Layered transition metal thiophosphates /MPX3/ as photoelectrodes in photoelectrochemical cells
NASA Technical Reports Server (NTRS)
Byvik, C. E.; Smith, B. T.; Reichman, B.
1982-01-01
Layered crystals of the transition metal thiophosphates were synthesized and characterized for use as photoelectrodes in photoelectrochemical cells. Crystals incorporating tin and manganese show n-type response while those with iron and nickel show p-type response. These materials have a measured indirect bandgap of about 2.1 eV. They show ability to photoelectrolyze water in acid solutions with onset potentials which change in a Nernstian way as the PH of the solution changes. The onset potential is near zero volts versus a saturated calomel electrode at pH 2. At n-type crystals, oxygen could be evolved upon irradiation at underpotentials of 850 mV and at p-type crystals, hydrogen could be evolved at underpotentials of 400 mV, indicating a net gain in energy conversion. All crystals were unstable in basic solution. Liquid junction photovoltaic cells in iodide-triiodide acid solution using these layered materials were also constructed and found to have low efficiences.
Effect of the microstructure of Ti-5Mo on the anodic dissolution in H/sub 2/SO/sub 4/
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Y.J.; Oriani, R.A.
1987-04-01
The effect of microstructure of the Ti-5Mo alloy on its anodic dissolution rate in sulfuric acid solution at various temperatures has been investigated. TiMo alloys exhibit a region of increased dissolution rate in the vicinity of +0.20 V (saturated calomel electrode (SCE)) in 10% H/sub 2/SO/sub 4/, the same potential region in which pure Mo exhibits a large anodic dissolution rate. Aging of Ti-5Mo at 350 C was found to lead to the formation of ..omega.. phase. Heat treatment caused larger passive currents in 10% H/sub 2/SO/sub 4/, but the critical passivation potentials and corrosion potentials were not significantly affected.more » Molybdenum was enriched in the oxide formed on aged Ti-5Mo at +0.23 V (SCE), in comparison with the Mo concentration found in the oxide on as-received Ti-5Mo.« less
Nguyen, Dzung Tuan; Nguyen, My Thanh; Ho, Giang Truong; Nguyen, Toan Ngoc; Reisberg, S; Piro, B; Pham, M C
2013-10-15
In this paper, poly(1,5-diaminonaphthalene) was interpenetrated into the network made of multiwalled carbon nanotubes (MWCNT) on platinum interdigital electrode (IDE) by electro-polymerization of 1,5-diaminonaphthalene (1,5-DAN). The electro-polymerization process of 1,5-DAN on MWCNT was controlled by scanning the cyclic voltage at 50 mV s(-1) scan rate between -0.1 V and +0.95 V vs. saturated calomel electrode (SCE). The results of voltammetric responses and Raman spectroscopy represented that the films MWCNT/poly(1,5-DAN) were successfully created by this polymerization process. The films MWCNT/poly(1,5-DAN) were investigated for gas-sensing to NO2 at low concentration level. The gas-sensing results showed that the response-recovery times were long and strongly affected by thickness of the film MWCNT/poly(1,5-DAN). Nevertheless, these films represented auspicious results for gas sensors operating at room temperature. Copyright © 2013 Elsevier B.V. All rights reserved.
Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.
Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B
2017-03-01
To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.
Peng, Sikan; Liang, Da-Wei; Diao, Peng; Liu, Yanyan; Lan, Fei; Yang, Yuhan; Lu, Shanfu; Xiang, Yan
2013-05-01
Understanding the electron-transfer mechanism and kinetic characteristics of bioanodes is greatly significant to enhance the electron-generating efficiencies in bioelectrochemical systems (BESs). A Nernst-ping-pong model is proposed here to investigate the kinetics and biochemical processes of bioanodes in a microbial electrolysis cell. This model can accurately describe the effects of the substrate (including substrate inhibition) and the anode potential on the current of bioanodes. Results show that the half-wave potential positively shifts as the substrate concentration increases, indicating that the rate-determining steps of anodic processes change from substrate oxidation to intracellular electron transport reaction. The anode potential has negligible effects on the enzymatic catalysis of anodic microbes in the range of -0.25 V to +0.1 V vs. a saturated calomel electrode. It turns out that to reduce the anodic energy loss caused by overpotential, higher substrate concentrations are preferred, if the substrate do not significantly and adversely affect the output current. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chen, Guiying; Sun, Hong; Hou, Shifeng
2016-06-01
In this study, sulfonated graphene oxide (SGO) was synthesized and characterized by Fourier transform infrared (FT-IR) spectroscopy and X-ray photoelectron spectroscopy (XPS). It was used to make Mb-SGO-Nafion composite films by coating myoglobin (Mb) on the glassy carbon electrodes (GCE). Positions of the Soret absorption bands suggested that Mb retained its native conformation in the films. Mb-SGO-Nafion film modified electrode showed a pair of well-defined and nearly reversible cyclic voltammetry peaks at around -0.39 V versus saturated calomel electrode (SCE) in pH 7.0 buffers, characteristic of heme Fe(III)/Fe(II) redox couples. Electrochemical parameters such as electron transfer rate constant (ks) and formal potential (E(o')) were estimated by fitting the data of square-wave voltammetry with nonlinear regression analysis. Experimental data demonstrated that the electron transfer between Mb and electrode was greatly facilitated and showed good electrocatalytic properties toward various substrates, such as H2O2 and NaNO2, with significant lowering of reduction overpotential. Copyright © 2016. Published by Elsevier Inc.
MoOx thin films deposited by magnetron sputtering as an anode for aqueous micro-supercapacitors
Liu, Can; Li, Zhengcao; Zhang, Zhengjun
2013-01-01
In order to examine the potential application of non-stoichiometric molybdenum oxide as anode materials for aqueous micro-supercapacitors, conductive MoOx films (2 ⩽ x ⩽ 2.3) deposited via RF magnetron sputtering at different temperatures were systematically studied for composition, structure and electrochemical properties in an aqueous solution of Li2SO4. The MoOx (x ≈ 2.3) film deposited at 150 °C exhibited a higher areal capacitance (31 mF cm−2 measured at 5 mV s−1), best rate capability and excellent stability at potentials below −0.1 V versus saturated calomel electrode, compared to the films deposited at room temperature and at higher temperatures. These superior properties were attributed to the multi-valence composition and mixed-phase microstructure, i.e., the coexistence of MoO2 nanocrystals and amorphous MoOx (2.3 < x ⩽ 3). A mechanism combining Mo(IV) oxidation/reduction on the hydrated MoO2 grain surfaces and cation intercalation/extrusion is proposed to illustrate the pseudo-capacitive process. PMID:27877625
MoO x thin films deposited by magnetron sputtering as an anode for aqueous micro-supercapacitors.
Liu, Can; Li, Zhengcao; Zhang, Zhengjun
2013-12-01
In order to examine the potential application of non-stoichiometric molybdenum oxide as anode materials for aqueous micro-supercapacitors, conductive MoO x films (2 ⩽ x ⩽ 2.3) deposited via RF magnetron sputtering at different temperatures were systematically studied for composition, structure and electrochemical properties in an aqueous solution of Li 2 SO 4 . The MoO x ( x ≈ 2.3) film deposited at 150 °C exhibited a higher areal capacitance (31 mF cm -2 measured at 5 mV s -1 ), best rate capability and excellent stability at potentials below -0.1 V versus saturated calomel electrode, compared to the films deposited at room temperature and at higher temperatures. These superior properties were attributed to the multi-valence composition and mixed-phase microstructure, i.e., the coexistence of MoO 2 nanocrystals and amorphous MoO x (2.3 < x ⩽ 3). A mechanism combining Mo(IV) oxidation/reduction on the hydrated MoO 2 grain surfaces and cation intercalation/extrusion is proposed to illustrate the pseudo-capacitive process.
MoOx thin films deposited by magnetron sputtering as an anode for aqueous micro-supercapacitors
NASA Astrophysics Data System (ADS)
Liu, Can; Li, Zhengcao; Zhang, Zhengjun
2013-12-01
In order to examine the potential application of non-stoichiometric molybdenum oxide as anode materials for aqueous micro-supercapacitors, conductive MoOx films (2 ⩽ x ⩽ 2.3) deposited via RF magnetron sputtering at different temperatures were systematically studied for composition, structure and electrochemical properties in an aqueous solution of Li2SO4. The MoOx (x ≈ 2.3) film deposited at 150 °C exhibited a higher areal capacitance (31 mF cm-2 measured at 5 mV s-1), best rate capability and excellent stability at potentials below -0.1 V versus saturated calomel electrode, compared to the films deposited at room temperature and at higher temperatures. These superior properties were attributed to the multi-valence composition and mixed-phase microstructure, i.e., the coexistence of MoO2 nanocrystals and amorphous MoOx (2.3 < x ⩽ 3). A mechanism combining Mo(IV) oxidation/reduction on the hydrated MoO2 grain surfaces and cation intercalation/extrusion is proposed to illustrate the pseudo-capacitive process.
Recovery of heavy metals from spent Ni-Cd batteries by a potentiostatic electrodeposition technique
NASA Astrophysics Data System (ADS)
Yang, Chun-Chen
Two heavy metals, Cd and Ni, have been separately recovered from spent AA-size Ni-Cd batteries by the potentiostatic electrodeposition and chemical precipitation methods, respectively. Various types and concentrations of HCl, H 2SO 4, and HNO 3 acids had been used as leach extractants. Experimental results indicate that the acid with the best leach capability is 4 M HCl. Three complexing reagents of NH 3, sodium acetate, sodium citrate have been chosen and tested. The most effective buffer is sodium citrate. The optimum mole ratio of metallic ion to citrate ion is 1:1. The recovery process for Cd metal is conducted by the potentiostatic electrodeposition in a leach electrolyte with a sodium citrate complex. The optimum applied potential for Cd recovery is in the range -1100 to -1120 mV (versus saturated calomel electrode (SCE)). The current efficiency for the recovery process is between 70 and 90% and depends strongly on the process parameters, e.g. liquor, concentration, applied potential, temperature, type of complex reagents, mole ratio, mass-transfer rate.
Simple electrodepositing of CoFe/Cu multilayers: Effect of ferromagnetic layer thicknesses
NASA Astrophysics Data System (ADS)
Tekgül, Atakan; Alper, Mürsel; Kockar, Hakan
2017-01-01
The CoFe/Cu magnetic multilayers were produced by changing CoFe ferromagnetic layers from 3 nm to 10 nm using electrodeposition. By now, the thinnest Cu (0.5 nm) layer thicknesses were used to see whether the GMR effect in the multilayers can be obtained or not since the pinning of non-magnetic layer between the ferromagnetic layers is required. For the proper depositions, the cyclic voltammograms was used, and the current-time transients were obtained. The Cu and CoFe layers were deposited at a cathode potential of -0.3 and -1.5 V with respect to saturated calomel electrode, respectively. From the XRD patterns, the multilayers were shown to be fcc crystal structures. For the magnetization measurements, saturation magnetization increases from 160 to 600 kA/m from 3 to 8 nm ferromagnetic layer thicknesses. And, the coercivity values increase until the 8 nm of the CoFe layer thickness. It is seen that the thin Cu layer (fixed at 0.5 nm) and pinholes support the random magnetization orientation and thus all multilayers exhibited the giant magnetoresistance (GMR) effect, and the highest GMR value was observed about 5.5%. And, the variation of GMR field sensitivity was calculated. The results show that the GMR and GMR sensitivity are compatible among the multilayers. The CoFe/Cu magnetic multilayers having GMR properties are used in GMR sensors and hard disk drive of the nano-technological devices.
Bogart, Justin A; Lewis, Andrew J; Schelter, Eric J
2015-01-19
Rare-earth metal cations have recently been demonstrated to be essential co-factors for the growth of the methanotrophic bacterium Methylacidiphilum fumariolicum SolV. A crystal structure of the rare-earth-dependent methanol dehydrogenase (MDH) includes a cerium cation in the active site. Herein, the Ce-MDH active site has been analyzed through DFT calculations. The results show the stability of the Ce(III)-pyrroloquinoline quinone (PQQ) semiquinone configuration. Calculations on the active oxidized form of this complex indicate a 0.81 eV stabilization of the PQQ(0) LUMO at cerium versus calcium, supporting the observation that the cerium cation in the active site confers a competitive advantage to Methylacidiphilum fumariolicum SolV. Using reported aqueous electrochemical data, a semi-empirical correlation was established based on cerium(IV/III) redox potentials. The correlation allowed estimation of the cerium oxidation potential of +1.35 V versus saturated calomel electrode (SCE) in the active site. The results are expected to guide the design of functional model complexes and alcohol-oxidation catalysts based on lanthanide complexes of biologically relevant quinones. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Enhanced Shewanella biofilm promotes bioelectricity generation.
Liu, Ting; Yu, Yang-Yang; Deng, Xiao-Peng; Ng, Chun Kiat; Cao, Bin; Wang, Jing-Yuan; Rice, Scott A; Kjelleberg, Staffan; Song, Hao
2015-10-01
Electroactive biofilms play essential roles in determining the power output of microbial fuel cells (MFCs). To engineer the electroactive biofilm formation of Shewanella oneidensis MR-1, a model exoelectrogen, we herein heterologously overexpressed a c-di-GMP biosynthesis gene ydeH in S. oneidensis MR-1, constructing a mutant strain in which the expression of ydeH is under the control of IPTG-inducible promoter, and a strain in which ydeH is under the control of a constitutive promoter. Such engineered Shewanella strains had significantly enhanced biofilm formation and bioelectricity generation. The MFCs inoculated with these engineered strains accomplished a maximum power density of 167.6 ± 3.6 mW/m(2) , which was ∼ 2.8 times of that achieved by the wild-type MR-1 (61.0 ± 1.9 mW/m(2) ). In addition, the engineered strains in the bioelectrochemical system at poised potential of 0.2 V vs. saturated calomel electrode (SCE) generated a stable current density of 1100 mA/m(2) , ∼ 3.4 times of that by wild-type MR-1 (320 mA/m(2) ). © 2015 Wiley Periodicals, Inc.
Reductive dehalogenation of haloacetic acids by hemoglobin-loaded carbon nanotube electrode.
Li, Yu-Ping; Cao, Hong-Bin; Zhang, Yi
2007-01-01
Hemoglobin (Hb) was immobilized on carbon nanotube (CNT) electrode to catalyze the dehalogenation of haloacetic acids (HAAs). FTIR and UV measurements were performed to investigate the activity-keep of Hb after immobilization on CNT. The electrocatalytic behaviors of the Hb-loaded electrode for the dehalogenation of HAAs were studied by cyclic voltammmetry and constant-potential electrolysis technique. An Hb-loaded packed-bed flow reactor was also constructed for bioelectrocatalytic dehalogenation of HAAs. The results showed that Hb retained its nature, the essential features of its native secondary structure, and its biocatalytic activity after immobilization on CNT. Chloroacetic acids and bromoacetic acids could be dehalogenated completely with Hb catalysis through a stepwise dehalogenation process at -0.400V (vs. saturated calomel electrode (SCE)) and -0.200V (vs. SCE), respectively. The removal of 10.5mM trichloroacetic acid and dichloroacetic acid is ca. 97% and 63%, respectively, with electrolysis for 300min at -0.400V (vs. SCE) using the Hb-loaded packed-bed flow reactor, and almost 100% of tribromoacetic acid and dibromoacetic acid was removed with electrolysis for 40min at -0.200V (vs. SCE). The average current efficiency of Hb-catalytic dehalogenation almost reaches 100%.
Zhang, Hui; Yin, Yajing; Wu, Ping; Cai, Chenxin
2012-01-15
Choline, as a marker of cholinergic activity in brain tissue, is very important in biological and clinical analysis, especially in the clinical detection of the neurodegenerative disorders disease. This work presents an electrochemical approach for the detection of choline based on prussian blue modified iron phosphate nanostructures (PB-FePO(4)). The obtained nanostructures showed a good catalysis toward the electroreduction of H(2)O(2), and an amperometric choline biosensor was developed by immobilizing choline oxidase on the PB-FePO(4) nanostructures. The biosensor exhibited a rapid response (ca. 2s), low detection limit (0.4±0.05 μM), wide linear range (2 μM to 3.2 mM), high sensitivity (~75.2 μAm M(-1) cm(-2)), as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid and 4-acetamidophenol did not cause obvious interference due to the low detection potential (-0.05 V versus saturated calomel electrode). This nanostructure could be used as a promise platform for the construction of other oxidase-based biosensors. Copyright © 2011 Elsevier B.V. All rights reserved.
Visible light CrO4(2-) reduction using the new CuAlO2/CdS hetero-system.
Brahimi, R; Bessekhouad, Y; Nasrallah, N; Trari, M
2012-06-15
In this study, 64% of hexavalent chromium Cr(VI) reduction from the initial concentration (10(-4) M) is reported under visible light using the (CuAlO(2)/CdS) hetero-system. In this new hetero-system, low doped CuAlO(2) delafossite, synthesized by sol-gel works as an electrons reservoir with a wide space charge region (440 nm). In this case, the electron transfer to chromate is mediated via the hexagonal CdS variety, whose conduction band level is at -1.08 V with respect to the saturated calomel electrode which is more negative than the CrO(4)(2-)/Cr(3+) level. This high reduction rate is achieved under optimized pH and CuAlO(2) percentage. Moreover, salicylic acid gives the best performance among hole scavengers and CuAlO(2) approaches 100% photostability at pH 7.5. The photo-catalytic process follows a pseudo first order kinetic with a half life of 2h. The reaction products are identified by UV-visible spectrophotometry and linear voltametry at a platinum rotating electrode. The results reveal the presence of Cr(3+) after irradiation. Copyright © 2012. Published by Elsevier B.V.
Huang, Minjia; Jiang, Guibin; Cai, Yaqi
2005-11-01
For SPME-HPLC, metal wires with better mechanical strength are preferred over the fused silica fibers. In this article, a novel composite polyaniline (CPANI) doped with PEG and polydimethylsiloxane coating (CPANI fiber) was prepared on a stainless steel wire by a three-electrode system: the fiber was used as the work electrode, a calomel electrode and a platinum electrode were used as the reference and the counter electrodes, respectively. To evaluate the new CPANI coating, the coating was used to extract three kinds of phenols (bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol) in water samples by direct-SPME mode and then desorbed in commercial SPME-HPLC interface to separation. The extraction procedure was also optimized. Five real water samples were investigated. Good recoveries were gained when environmental samples were analyzed.
Feng, Wei; Xu, Jinxia; Jiang, Linhua; Song, Yingbin; Cao, Yalong; Tan, Qiping
2018-01-01
To improve the repair effect of electrochemical chloride extraction, a modified electrode configuration is applied in this investigation. In this configuration, two auxiliary electrodes placed in the anodic and cathodic electrolytes were used as the anode and cathode, respectively. Besides this, the steel in the mortar was grounded to protect it from corrosion. By a comparative experiment, the potential evolution, various ions concentrations (Cl−, OH−, Na+, and K+) in different mortar depths, the corrosion potential, and the current density of the steel were measured. The results indicate that compared to electrochemical chloride extraction with the traditional electrode configuration, this electrochemical chloride extraction method with a modified electrode configuration has a similar chloride removal ratio. Besides this, potential of steel is just about 800 mV for a saturated calomel electrode (SCE) during the treatment, which did not reach the hydrogen evolution potential. The phenomenon of the accumulation of OH−, Na+, and K+ did not occur when the modified electrode configuration is applied. Additionally, higher corrosion potentials and lower corrosion current rates were measured after performing electrochemical chloride extraction with the modified electrode configuration. Additionally, it is a short period of time for the steel to go from activation to passivation. On this basis, the modified electrode configuration may overcome the drawbacks of electrochemical chloride extraction. PMID:29389855
NASA Astrophysics Data System (ADS)
Paul, S.; Lu, Q.; Harvey, M. D. F.
2015-04-01
Thermally sprayed aluminum (TSA) coating has been increasingly used for the protection of carbon steel offshore structures, topside equipment, and flowlines/pipelines exposed to both marine atmospheres and seawater immersion conditions. In this paper, the effectiveness of TSA coatings in preventing localized corrosion, such as pitting and crevice corrosion of 25% Cr superduplex stainless steel (SDSS) in subsea applications, has been investigated. Welded 25% Cr SDSS (coated and uncoated) with and without defects, and surfaces coated with epoxy paint were also examined. Pitting and crevice corrosion tests, on welded 25% Cr SDSS specimens with and without TSA/epoxy coatings, were conducted in recirculated, aerated, and synthetic seawater at 90 °C for 90 days. The tests were carried out at both the free corrosion potentials and an applied cathodic potential of -1100 mV saturated calomel electrode. The acidity (pH) of the test solution was monitored daily and adjusted to between pH 7.5 and 8.1, using dilute HCl solution or dilute NaOH, depending on the pH of the solution measured during the test. The test results demonstrated that TSA prevented pitting and crevice corrosion of 25% Cr SDSS in artificial seawater at 90 °C, even when 10-mm-diameter coating defect exposing the underlying steel was present.
Eashwar, M; Subramanian, G; Palanichamy, S; Rajagopal, G; Madhu, S; Kamaraj, P
2009-01-01
Type-316 stainless steel (SS) was investigated as the cathode in galvanic couples in full-strength seawater from the Gulf of Mannar on the southeast coast of India. Tests were devised to examine the impact of SS cathodes on anode materials with or without the accrual of marine biofilms. Biofilmed SS cathodes significantly enhanced the rate of corrosion of nickel, causing noble shifts in the couple potentials. With mild steel and zinc as the anodes, calcareous deposits developed quite rapidly on the SS cathodes and led to a significant reduction of bacterial numbers. The calcareous deposits also caused substantial reduction of galvanic corrosion rates for mild steel, whereas there was no difference for zinc. The deposits were identified by XRD as essentially carbonates, oxides and hydroxides of calcium and magnesium. Potentiodynamic polarization performed on the actual couples after disconnection and equilibration provided reasonable interpretations of the galvanic corrosion trends. Data from this work suggest that a potential of about -0.70 V vs. saturated calomel electrode (SCE) should provide optimum protection of SS in warmer, full-strength seawater that supports the precipitation of calcareous deposits. The criterion commonly recommended for temperate conditions of lower water temperature and estuarine waters of lower alkalinity is -1.0 V (SCE).
NASA Astrophysics Data System (ADS)
Douafer, S.; Lahmar, H.; Benamira, M.; Rekhila, G.; Trari, M.
2018-07-01
Nanocrystalline lithium manganese oxide (LiMn2O4), synthesized by the sol-gel method, crystallizes in the spinel structure. The physical, electrical, and photoelectrochemical properties were studied for the photocatalytic degradation of methyl orange, a toxic compound, under solar irradiation. The diffuse reflectance spectrum allowed the direct band gap (1.99 eV) to be calculated. The Fourier transform IR spectrum contained all the characteristic peaks of the spinel LiMn2O4, which exhibited n-type behavior. The thermal evolution of the electrical conductivity exhibited an Arrhenius-type behavior with an activation energy of 0.27 eV. The Mott-Schottky curve allowed the determination of the flat band potential (-0.24 V vs. the saturated calomel electrode) as well as the carrier density (1.78 × 1021 cm-3). The detoxification of water containing methyl orange with LiMn2O4 as a photocatalyst was successfully completed. Total degradation for an initial concentration of 10-4 M methyl orange at pH ∼3 and 25 °C was obtained in less than 5 h under solar irradiation. No adsorption was obtained in the dark in the presence of LiMn2O4.
Corrosion behavior of HPT-deformed TiNi alloys in cell culture medium
NASA Astrophysics Data System (ADS)
Shri, D. N. Awang; Tsuchiya, K.; Yamamoto, A.
2017-09-01
In recent years there are growing interest in fabrication of bulk nanostructured metals and alloys by using severe plastic deformation (SPD) techniques as new alternative in producing bulk nanocrystalline materials. These techniques allows for processing of bulk, fully dense workpiece with ultrafine grains. Metal undergoes SPD processing in certain techniques such as high pressure torsion (HPT), equal-channel angular pressing (ECAP) or multi-directional forging (MDF) are subjected to extensive hydrostatic pressure that may be used to impart a very high strain to the bulk solid without the introduction of any significant change in overall dimension of the sample. The change in the structure (small grain size and high-volume fraction of grain boundaries) of the material may result in the corrosion behavior different from that of the coarse-grained material. Electrochemical measurements were done to understand the corrosion behavior of TiNi alloys before and after HPT deformation. The experiment was carried out using standard three electrode setup (a sample as working electrode; a platinum wire as a counter electrode and a saturated calomel electrode in saturated KCl as a reference electrode) with the surface area of 26.42 mm2 exposed to the EMEM+10% FBS cell culture medium. The measurements were performed in an incubator with controlled environment at 37 °C and 5% CO2, simulating the cell culture condition. The potential of the specimen was monitored over 1 hour, and the stabilized potential was used as the open-circuit potential (EOCP). Potentiodynamic curves were scanned in the potential range from -0.5 V to 1.5 V relative to the EOCP, at a rate of 0.5 mV/s. The result of OCP-time measurement done in the cell culture medium shows that the OCP of HPT-deformed samples shifts towards to the more positive rather than that of BHPT samples. The OCP of deformed samples were ennobled to more than +70 mV for Ti-50mol%. The shift of OCP towards the nobler direction indicates the passive nature of native oxides formed on the surface of the samples. The polarization curve, on the other hand, indicates that the HPT deformation was found to shift the passive current to nobler region. The passive region current density is found to be lower than that of the BHPT, suggesting the passive film formed on the surface of HPT-deformed samples is more protective than that of the BHPT sample. This study has shown that nanocrystallization and amorphization induced by severe plastic deformation change the corrosion behavior of TiNi alloys.
Joint DoD Demonstration And Validation Of Magnesium-Rich Primer Coating Technology
2012-01-01
Recovery Act SCE .....................................Standard Calomel Electrode xi TCP ..................................... Trivalent Chromium ...8 performed the best, followed by trivalent chromium pretreatment (TCP), with the panel that did not receive any chemical pretreatment performing...Abraded) MIL-DTL-81706 Type II – Trivalent Chromium (Alodine T5900) MIL-DTL-81706 Type I – Hexavalent Chromium No Chemical Pretreatment MIL-DTL-81706
NASA Astrophysics Data System (ADS)
Rana, Moumita; Arora, Gunjan; Gautam, Ujjal K.
2015-02-01
Highly stable, cost-effective electrocatalysts facilitating oxygen reduction are crucial for the commercialization of membrane-based fuel cell and battery technologies. Herein, we demonstrate that protein-rich soya chunks with a high content of N, S and P atoms are an excellent precursor for heteroatom-doped highly graphitized carbon materials. The materials are nanoporous, with a surface area exceeding 1000 m2 g-1, and they are tunable in doping quantities. These materials exhibit highly efficient catalytic performance toward oxygen reduction reaction (ORR) with an onset potential of -0.045 V and a half-wave potential of -0.211 V (versus a saturated calomel electrode) in a basic medium, which is comparable to commercial Pt catalysts and is better than other recently developed metal-free carbon-based catalysts. These exhibit complete methanol tolerance and a performance degradation of merely ˜5% as compared to ˜14% for a commercial Pt/C catalyst after continuous use for 3000 s at the highest reduction current. We found that the fraction of graphitic N increases at a higher graphitization temperature, leading to the near complete reduction of oxygen. It is believed that due to the easy availability of the precursor and the possibility of genetic engineering to homogeneously control the heteroatom distribution, the synthetic strategy is easily scalable, with further improvement in performance.
Rana, Moumita; Arora, Gunjan; Gautam, Ujjal K
2015-01-01
Highly stable, cost-effective electrocatalysts facilitating oxygen reduction are crucial for the commercialization of membrane-based fuel cell and battery technologies. Herein, we demonstrate that protein-rich soya chunks with a high content of N, S and P atoms are an excellent precursor for heteroatom-doped highly graphitized carbon materials. The materials are nanoporous, with a surface area exceeding 1000 m2 g−1, and they are tunable in doping quantities. These materials exhibit highly efficient catalytic performance toward oxygen reduction reaction (ORR) with an onset potential of −0.045 V and a half-wave potential of −0.211 V (versus a saturated calomel electrode) in a basic medium, which is comparable to commercial Pt catalysts and is better than other recently developed metal-free carbon-based catalysts. These exhibit complete methanol tolerance and a performance degradation of merely ∼5% as compared to ∼14% for a commercial Pt/C catalyst after continuous use for 3000 s at the highest reduction current. We found that the fraction of graphitic N increases at a higher graphitization temperature, leading to the near complete reduction of oxygen. It is believed that due to the easy availability of the precursor and the possibility of genetic engineering to homogeneously control the heteroatom distribution, the synthetic strategy is easily scalable, with further improvement in performance. PMID:27877746
Zuo, Wenhua; Xie, Chaoyue; Xu, Pan; Li, Yuanyuan; Liu, Jinping
2017-09-01
One of the key challenges of aqueous supercapacitors is the relatively low voltage (0.8-2.0 V), which significantly limits the energy density and feasibility of practical applications of the device. Herein, this study reports a novel Ni-Mn-O solid-solution cathode to widen the supercapacitor device voltage, which can potentially suppress the oxygen evolution reaction and thus be operated stably within a quite wide potential window of 0-1.4 V (vs saturated calomel electrode) after a simple but unique phase-transformation electrochemical activation. The solid-solution structure is designed with an ordered array architecture and in situ nanocarbon modification to promote the charge/mass transfer kinetics. By paring with commercial activated carbon anode, an ultrahigh voltage asymmetric supercapacitor in neutral aqueous LiCl electrolyte is assembled (2.4 V; among the highest for single-cell supercapacitors). Moreover, by using a polyvinyl alcohol (PVA)-LiCl electrolyte, a 2.4 V hydrogel supercapacitor is further developed with an excellent Coulombic efficiency, good rate capability, and remarkable cycle life (>5000 cycles; 95.5% capacity retention). Only one cell can power the light-emitting diode indicator brightly. The resulting maximum volumetric energy density is 4.72 mWh cm -3 , which is much superior to previous thin-film manganese-oxide-based supercapacitors and even battery-supercapacitor hybrid devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lead Sulfide Cathode for Quantum Dot Solar Cells: Electrosynthesis and Characterization
NASA Astrophysics Data System (ADS)
Van Le, Nghiem; Nguyen, Hoang Thai; Le, Hai Viet; Nguyen, Thoa Thi Phuong
2017-01-01
Deposition of lead sulfide (PbS) nanocrystalline thin films onto conducting fluorine-doped tin oxide (FTO) glass has been performed by cyclic voltammetry (CV) in 1.5 mM solution of lead nitrate and sodium thiosulfate at 100 mV s-1 scan rate in the potential range of -1.0 V to 0.0 V versus saturated calomel electrode. X-ray diffraction analysis and scanning electron microscopy revealed formation of cubic PbS crystals with size of 100 nm to 150 nm after 50 cycles. High electrocatalytic activity of the synthesized PbS film for the S2-/S n 2- redox couple, used as a mediator for quantum dot solar cells (QDSCs), was demonstrated by electrochemical impedance spectroscopy and CV measurements. The prepared PbS/FTO was used as a counterelectrode to fabricate PbS-QDSCs with a photoanode consisting of CdS/CdSe quantum dots adsorbed on mesoporous TiO2 film and a polysulfide solution electrolyte. The performance of the PbS-QDSC was compared with a QDSC with a platinum counterelectrode (Pt-QDSC). It was found that, using the same fabrication conditions, the performance of the PbS-QDSC was better than that of the Pt-QDSC. At 1 sun (100 mW cm-2) simulated light, average energy conversion efficiency of 2.14%, short-circuit current of 9.22 mA cm-2, open-circuit potential of 0.50 V, and fill factor of 0.47 were achieved by the fabricated PbS-QDSC.
Fish, F.F.; McKernan, D.L.
1940-01-01
Octomitus salmonis was introduced to fish culture during the early twenties. This easily found and widely distributed parasite, once recognized, was soon held responsible for practically every ailment noted in trout hatcheries at that time. Such a reputation was doubtless deserved in some instances, but unquestionably many losses ascribed to Octomitus salmonis actually resulted from such troubles as bacterial gill disease, which was then unknown, or from less easily found parasites such as Costia necatrlx. As might be expected, the pendulum of opinion gradually swung to the other extreme.
NASA Astrophysics Data System (ADS)
Tekgül, Atakan; Kockar, Hakan; Kuru, Hilal; Alper, Mürsel; ÜnlÜ, C. Gökhan
2018-03-01
The electrochemical, structural and magnetic properties of CoCu/Cu multilayers electrodeposited at different cathode potentials were investigated from a single bath. The Cu layer deposition potentials were selected as - 0.3, V - 0.4 V, and - 0.5 V with respect to saturated calomel electrode (SCE) while the Co layer deposition potential was constant at - 1.5 V versus SCE. For the electrochemical analysis, the current-time transients were obtained. The amount of noble non-magnetic (Cu) metal materials decreased with the increase of deposition potentials due to anomalous codeposition. Further, current-time transient curves for the Co layer deposition and capacitance were calculated. In the structural analysis, the multilayers were found to be polycrystalline with both Co and Cu layers adopting the face-centered cubic structure. The (111) peak shifts towards higher angle with the increase of the deposition potentials. Also, the lattice parameters of the multilayers decrease from 0.3669 nm to 0.3610 nm with the increase of the deposition potentials from - 0.3 V to - 0.5 V, which corresponds to the bulk values of Cu and Co, respectively. The electrochemical and structural results demonstrate that the amount of Co atoms increased and the Cu atoms decreased in the layers with the increase of deposition potentials due to anomalous codeposition. For magnetic measurements, the saturation magnetizations, M_s obtained from the magnetic curves of the multilayers were obtained as 212 kA/m, 276 kA/m, and 366 kA/m with - 0.3 V, - 0.4 V, and - 0.5 V versus SCE, respectively. It is seen that the M_s values increased with the increase of the deposition potentials confirming the increase of the Co atoms and decrease of the Cu amount. The results of electrochemical and structural analysis show that the deposition potentials of non-magnetic layers plays important role on the amount of magnetic and non-magnetic materials in the layers and thus on the magnetic properties of the multilayers.
Probing Aspergillus niger glucose oxidase with pentacyanoferrate(III) aza- and thia-complexes.
Kulys, J; Tetianec, L; Ziemys, A
2006-10-01
Complexes of pentacyanoferrate(III) and biologically relevant ligands, such as pyridine, pyrazole, imidazole, histidine, and other aza- and thia-heterocycles, were synthesized. Their spectral, electrochemical properties, electron exchange constants, electronic structure parameters, and reactivity with glucose oxidase from Aspergillus niger were determined. The formation of the complexes following ammonia replacement by the ligands was associated with the appearance of a new band of absorbance in the visible spectrum. The constants of the complexes formation calculated at a ligand-pentacyanoferrate(III) concentrations ratio of 10:1, were 7.5 x 10(-5), 7.7 x 10(-5), and 1.8 x 10(-3) s(-1) for benzotriazole, benzimidazole, and aminothiazole ligands, respectively. The complexes showed quasi-reversible redox conversion at a glassy carbon electrode. The redox potential of the complexes spanned the potential range from 70 to 240 mV vs. saturated calomel electrode (SCE) at pH7.2. For most of the complexes self-exchange constants (k(11)) were similar to or larger than that of hexacyanoferrate(III) (ferricyanide). The complexes containing pyridine derivatives and thia-heterocyclic ligands held a lower value of k(11) than that of ferricyanide. All complexes reacted with reduced glucose oxidase at pH7.2. The reactivity of the complex containing pyrazole was the largest in comparison to the rest of the complexes. Correlations between the complexes' reactivity and both the free energy of reaction and k(11) shows that the reactivity of pentacyanoferrates obeys the principles of Marcus's electron transfer theory. The obtained data suggest that large negative charges of the complexes decrease their reactivity.
Hou, Chuantao; Yang, Dapeng; Liang, Bo; Liu, Aihua
2014-06-17
The power output and stability of enzyme-based biofuel cells (BFCs) is greatly dependent on the properties of both the biocathode and bioanode, which may be adapted for portable power production. In this paper, a novel highly uniform three-dimensional (3D) macroporous gold (MP-Au) film was prepared by heating the gold "supraspheres", which were synthesized by a bottom-up protein templating approach, and followed by modification of laccase on the MP-Au film by covalent immobilization. The as-prepared laccase/MP-Au biocathode exihibited an onset potential of 0.62 V versus saturated calomel electrode (SCE, or 0.86 V vs NHE, normal hydrogen electrode) toward O2 reduction and a high catalytic current of 0.61 mAcm(-2). On the other hand, mutated glucose dehydrogenase (GDH) surface displayed bacteria (GDH-bacteria) were used to improve the stability of the glucose oxidation at the bioanode. The as-assembled membraneless glucose/O2 fuel cell showed a high power output of 55.8 ± 2.0 μW cm(-2) and open circuit potential of 0.80 V, contributing to the improved electrocatalysis toward O2 reduction at the laccase/MP-Au biocathode. Moreover, the BFC retained 84% of its maximal power density even after continuous operation for 55 h because of the high stability of the bacterial surface displayed GDH mutant toward glucose oxidation. Our findings may be promising for the development of more efficient glucose BFC for portable battery or self-powered device applications.
The feasibility and application of PPy in cathodic polarization antifouling.
Jia, Meng-Yang; Zhang, Zhi-Ming; Yu, Liang-Min; Wang, Jia; Zheng, Tong-Tong
2018-04-01
Cathodic polarization antifouling deserves attention because of its environmentally friendly nature and good sustainability. It has been proven that cathodic voltages applied on metal substrates exhibit outstanding antifouling effects. However, most metals immersed in marine environment are protected by insulated anticorrosive coatings, restricting the cathodic polarization applied on metals. This study developed a conducting polypyrrole (PPy)/acrylic resin coating (σ = 0.18 Scm -1 ), which can be applied in cathodic polarization antifouling. The good stability and electro-activity of PPy in the negative polarity zone in alkalescent NaCl solution were verified by linear sweep voltammetry (LSV), chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), demonstrating the feasibility of PPy as cathodic polarization material. Furthermore, the antifouling effects of PPy/acrylicresin coating on 24-h old Escherichia coli bacteria (E. coli) which formed on PPy/acrylic resin-coated plastic plate were measured under different cathodic potentials and treatment time, characterized by fluorescent microscope. The results suggest that at cathodic potential around -0.5 V (vs. saturated calomel electrode (SCE)), there was little trace of attached bacteria on the substrate after 20 min of treatment. PPy/acrylicresin-coated substrates were also subjected to repeated cycles of biofilm formation and electrochemical removal, where high removal efficiencies were maintained throughout the total polarization process. Under these conditions, the generation of hydrogen peroxide is believed to be responsible for the antifouling effects because of causing oxidative damage to cells, suggesting the potential of the proposed technology for application on insulated surfaces in various industrial settings. Copyright © 2018 Elsevier B.V. All rights reserved.
Electroactivity of phototrophic river biofilms and constitutive cultivable bacteria.
Lyautey, Emilie; Cournet, Amandine; Morin, Soizic; Boulêtreau, Stéphanie; Etcheverry, Luc; Charcosset, Jean-Yves; Delmas, François; Bergel, Alain; Garabetian, Frédéric
2011-08-01
Electroactivity is a property of microorganisms assembled in biofilms that has been highlighted in a variety of environments. This characteristic was assessed for phototrophic river biofilms at the community scale and at the bacterial population scale. At the community scale, electroactivity was evaluated on stainless steel and copper alloy coupons used both as biofilm colonization supports and as working electrodes. At the population scale, the ability of environmental bacterial strains to catalyze oxygen reduction was assessed by cyclic voltammetry. Our data demonstrate that phototrophic river biofilm development on the electrodes, measured by dry mass and chlorophyll a content, resulted in significant increases of the recorded potentials, with potentials of up to +120 mV/saturated calomel electrode (SCE) on stainless steel electrodes and +60 mV/SCE on copper electrodes. Thirty-two bacterial strains isolated from natural phototrophic river biofilms were tested by cyclic voltammetry. Twenty-five were able to catalyze oxygen reduction, with shifts of potential ranging from 0.06 to 0.23 V, cathodic peak potentials ranging from -0.36 to -0.76 V/SCE, and peak amplitudes ranging from -9.5 to -19.4 μA. These isolates were diversified phylogenetically (Actinobacteria, Firmicutes, Bacteroidetes, and Alpha-, Beta-, and Gammaproteobacteria) and exhibited various phenotypic properties (Gram stain, oxidase, and catalase characteristics). These data suggest that phototrophic river biofilm communities and/or most of their constitutive bacterial populations present the ability to promote electronic exchange with a metallic electrode, supporting the following possibilities: (i) development of electrochemistry-based sensors allowing in situ phototrophic river biofilm detection and (ii) production of microbial fuel cell inocula under oligotrophic conditions.
Liu, Jie; Fan, Xiayue; Liu, Xiaorui; Song, Zhishuang; Deng, Yida; Han, Xiaopeng; Hu, Wenbin; Zhong, Cheng
2017-06-07
A new approach has been developed for in situ preparing cubic-shaped Pt particles with (100) preferential orientation on the surface of the conductive support by using a quick, one-step, and clean electrochemical method with periodic square-wave potential. The whole electrochemical deposition process is very quick (only 6 min is required to produce cubic Pt particles), without the use of particular capping agents. The shape and the surface structure of deposited Pt particles can be controlled by the lower and upper potential limits of the square-wave potential. For a frequency of 5 Hz and an upper potential limit of 1.0 V (vs saturated calomel electrode), as the lower potential limit decreases to the H adsorption potential region, the Pt deposits are changed from nearly spherical particles to cubic-shaped (100)-oriented Pt particles. High-resolution transmission electron microscopy and selected-area electron diffraction reveal that the formed cubic Pt particles are single-crystalline and enclosed by (100) facets. Cubic Pt particles exhibit characteristic H adsorption/desorption peaks corresponding to the (100) preferential orientation. Ge irreversible adsorption indicates that the fraction of wide Pt(100) surface domains is 47.8%. The electrocatalytic activities of different Pt particles are investigated by ammonia electro-oxidation, which is particularly sensitive to the amount of Pt(100) sites, especially larger (100) domains. The specific activity of cubic Pt particles is 3.6 times as high as that of polycrystalline spherical Pt particles, again confirming the (100) preferential orientation of Pt cubes. The formation of cubic-shaped Pt particles is related with the preferential electrochemical deposition and dissolution processes of Pt, which are coupled with the periodic desorption and adsorption processes of O-containing species and H adatoms.
Electroactivity of Phototrophic River Biofilms and Constitutive Cultivable Bacteria ▿ †
Lyautey, Emilie; Cournet, Amandine; Morin, Soizic; Boulêtreau, Stéphanie; Etcheverry, Luc; Charcosset, Jean-Yves; Delmas, François; Bergel, Alain; Garabetian, Frédéric
2011-01-01
Electroactivity is a property of microorganisms assembled in biofilms that has been highlighted in a variety of environments. This characteristic was assessed for phototrophic river biofilms at the community scale and at the bacterial population scale. At the community scale, electroactivity was evaluated on stainless steel and copper alloy coupons used both as biofilm colonization supports and as working electrodes. At the population scale, the ability of environmental bacterial strains to catalyze oxygen reduction was assessed by cyclic voltammetry. Our data demonstrate that phototrophic river biofilm development on the electrodes, measured by dry mass and chlorophyll a content, resulted in significant increases of the recorded potentials, with potentials of up to +120 mV/saturated calomel electrode (SCE) on stainless steel electrodes and +60 mV/SCE on copper electrodes. Thirty-two bacterial strains isolated from natural phototrophic river biofilms were tested by cyclic voltammetry. Twenty-five were able to catalyze oxygen reduction, with shifts of potential ranging from 0.06 to 0.23 V, cathodic peak potentials ranging from −0.36 to −0.76 V/SCE, and peak amplitudes ranging from −9.5 to −19.4 μA. These isolates were diversified phylogenetically (Actinobacteria, Firmicutes, Bacteroidetes, and Alpha-, Beta-, and Gammaproteobacteria) and exhibited various phenotypic properties (Gram stain, oxidase, and catalase characteristics). These data suggest that phototrophic river biofilm communities and/or most of their constitutive bacterial populations present the ability to promote electronic exchange with a metallic electrode, supporting the following possibilities: (i) development of electrochemistry-based sensors allowing in situ phototrophic river biofilm detection and (ii) production of microbial fuel cell inocula under oligotrophic conditions. PMID:21642402
Analysis of gene network robustness based on saturated fixed point attractors
2014-01-01
The analysis of gene network robustness to noise and mutation is important for fundamental and practical reasons. Robustness refers to the stability of the equilibrium expression state of a gene network to variations of the initial expression state and network topology. Numerical simulation of these variations is commonly used for the assessment of robustness. Since there exists a great number of possible gene network topologies and initial states, even millions of simulations may be still too small to give reliable results. When the initial and equilibrium expression states are restricted to being saturated (i.e., their elements can only take values 1 or −1 corresponding to maximum activation and maximum repression of genes), an analytical gene network robustness assessment is possible. We present this analytical treatment based on determination of the saturated fixed point attractors for sigmoidal function models. The analysis can determine (a) for a given network, which and how many saturated equilibrium states exist and which and how many saturated initial states converge to each of these saturated equilibrium states and (b) for a given saturated equilibrium state or a given pair of saturated equilibrium and initial states, which and how many gene networks, referred to as viable, share this saturated equilibrium state or the pair of saturated equilibrium and initial states. We also show that the viable networks sharing a given saturated equilibrium state must follow certain patterns. These capabilities of the analytical treatment make it possible to properly define and accurately determine robustness to noise and mutation for gene networks. Previous network research conclusions drawn from performing millions of simulations follow directly from the results of our analytical treatment. Furthermore, the analytical results provide criteria for the identification of model validity and suggest modified models of gene network dynamics. The yeast cell-cycle network is used as an illustration of the practical application of this analytical treatment. PMID:24650364
[The water content reference material of water saturated octanol].
Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan
2011-03-01
The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.
This study presents the integrated volume method for estimating saturation pressure and enthalpy of vaporization of a whole aerosol distribution. We measure the change of total volume of an aerosol distribution between a reference state and several heated states, with the heating...
Calibration of Relative Humidity Devices in Low-pressure, Low-temperature CO2 Environment
NASA Astrophysics Data System (ADS)
Genzer, Maria; Polkko, Jouni; Nikkanen, Timo; Hieta, Maria; Harri, Ari-Matti
2017-04-01
Calibration of relative humidity devices requires in minimum two humidity points - dry (0%RH) and (near)saturation (95-100%RH) - over the expected operational temperature and pressure range of the device. In terrestrial applications these are relatively easy to achieve using for example N2 gas as dry medium, and water vapor saturation chambers for producing saturation and intermediate humidity points. But for example in applications intended for meteorological measurements on Mars there is a need to achieve at least dry and saturation points in low-temperature, low-pressure CO2 environment. We have developed a custom-made, small, relatively low-cost calibration chamber able to produce both dry points and saturation points in Martian range pressure CO2, in temperatures down to -70°C. The system utilizes a commercially available temperature chamber for temperature control, vacuum vessels and pumps. The main pressure vessel with the devices under test inside is placed inside the temperature chamber, and the pressure inside is controlled by pumps and manual valves and monitored with a commercial pressure reference with calibration traceable to national standards. Air, CO2, or if needed another gas like N2, is used for filling the vessel until the desired pressure is achieved. Another pressure vessel with a dedicated pressure pump is used as the saturation chamber. This vessel is placed in the room outside the temperature chamber, partly filled with water and used for achieving saturated water vapor in room-temperature low-pressure environment. The saturation chamber is connected to the main pressure vessel via valves. In this system dry point, low-pressure CO2 environment is achieved by filling the main pressure vessel with dry CO2 gas until the desired pressure is achieved. A constant flow of gas is maintained with the pump and valves and monitored with the pressure reference. The saturation point is then achieved by adding some water vapor from the saturation chamber to the main pressure vessel. The amount of water vapor added is also monitored with the pressure reference. For example in -70°C, very small absolute amount of water vapor corresponding to 1 Pa [1][2] pressure rise in the main chamber results in humidity saturation. As the flow of both CO2 and water vapor is kept constant, the main chamber is served with water vapor all the time, keeping the uniform saturation conditions inside the vessel even if some of the water freezes on the vessel and pipe walls. [1] Goff, J. A., and S. Gratch (1946) Low-pressure properties of water from -160 to 212 °F, Transactions of the American Society of Heating and Ventilating Engineers [2] Goff, J. A. (1957) Saturation pressure of water on the new Kelvin temperature scale, Transactions of the American Society of Heating and Ventilating Engineers
Oxygen saturation profile in healthy preterm infants.
Harigopal, S; Satish, H P; Taktak, A F G; Southern, K W; Shaw, N J
2011-09-01
To establish a reference range for oxygen saturation (SpO(2)) in well preterm infants to guide home oxygen therapy using a pulse oximeter and Pulse Oximetry Data Analysis Software (PODS). SpO(2) and heart-rate profiles of healthy preterm infants receiving mechanical ventilation for less than 6 h and supplemental oxygen for less than 48 h were monitored using a pulse oximeter. The stored data were downloaded from the monitor to a personal computer as individual files. Each infant's files of SpO(2) were subsequently displayed in graphic form, and a reference range was constructed using dedicated software, PODS. 43 infants were studied. The median value of all infants mean SpO(2) values was 95% (range 92-99%). The median duration of saturations less than 85% and between 85% and 90 % were 1% and 2% respectively. Using the study group median, 5th and 95th percentiles, a cumulative frequency curve of time against SpO(2) value was constructed (representing the reference range of SpO(2) profiles in healthy preterm infants). The SpO(2) reference range can be used as an easy and practical guide to compare SpO(2) profiles of infants on home oxygen therapy and guide their oxygen therapy.
2011-07-13
Anton A. Stoorvogel b, Håvard Fjær Grip a aSchool of Electrical Engineering and Computer Science, Washington State University, Pullman, WA 99164-2752...utwente.nl ( Anton A. Stoorvogel), grip@ieee.org (Håvard Fjær Grip). of a double integrator controlled by a saturating linear static state feedback...References Chitour, Y., 2001. On the Lp stabilization of the double integrator subject to input saturation. ESAIM: Control, Optimization and Calculus
Nocturnal oxygen saturation profiles of healthy term infants
Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe
2015-01-01
Objective Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Design Prospective longitudinal cohort study. Setting Sleep-laboratory. Patients 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Interventions Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Main outcome measurements Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Results Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. Conclusions SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. PMID:25063836
Zou, An-Min; Kumar, Krishna Dev
2012-07-01
This brief considers the attitude coordination control problem for spacecraft formation flying when only a subset of the group members has access to the common reference attitude. A quaternion-based distributed attitude coordination control scheme is proposed with consideration of the input saturation and with the aid of the sliding-mode observer, separation principle theorem, Chebyshev neural networks, smooth projection algorithm, and robust control technique. Using graph theory and a Lyapunov-based approach, it is shown that the distributed controller can guarantee the attitude of all spacecraft to converge to a common time-varying reference attitude when the reference attitude is available only to a portion of the group of spacecraft. Numerical simulations are presented to demonstrate the performance of the proposed distributed controller.
Anisotropic Light Diffraction by Ultrasound in Crystals with Strong Acoustic Anisotropy
NASA Astrophysics Data System (ADS)
Voloshin, Andrey S.; Balakshy, Vladimir I.
In modern acousto-optics, crystalline materials are used predominantly for manufacturing acousto-optic instruments. Among these materials, such crystals as paratellurite, tellurium, calomel, TAS and some others occupy a prominent place, which are distinguished by exceptionally large anisotropy of acoustic properties. In this work, the influence of acoustic beam energy walk-off on characteristics of Bragg diffraction of light is studied by the example of tellurium crystal. It is shown that the walk-off can substantially change angular and frequency ranges, resulting in their narrowing or broadening subject to position of the operating point in the Bragg angle frequency characteristic. Coefficients of broadening are introduced for characterization of this effect.
NASA Astrophysics Data System (ADS)
Li, Gang; Yu, Yue; Zhang, Cui; Lin, Ling
2017-09-01
The oxygen saturation is one of the important parameters to evaluate human health. This paper presents an efficient optimization method that can improve the accuracy of oxygen saturation measurement, which employs an optical frequency division triangular wave signal as the excitation signal to obtain dynamic spectrum and calculate oxygen saturation. In comparison to the traditional method measured RMSE (root mean square error) of SpO2 which is 0.1705, this proposed method significantly reduced the measured RMSE which is 0.0965. It is notable that the accuracy of oxygen saturation measurement has been improved significantly. The method can simplify the circuit and bring down the demand of elements. Furthermore, it has a great reference value on improving the signal to noise ratio of other physiological signals.
Corrosion behaviour of high copper dental amalgams.
Yap, A U J; Ng, B L; Blackwood, D J
2004-06-01
This study evaluated the corrosion behaviour of two high copper dental amalgam alloys [Dispersalloy (Dentsply-Caulk) and Tytin (Kerr)] in different electrolytes. Amalgam specimens were prepared, coupled to a copper wire, cemented into glass tubes and polished to a 600-grit finish. A corrosion cell was prepared using a carbon counter-electrode, a standard calomel electrode as the reference and amalgam as the working electrode. The alloys were tested in the following mediums at 37 degrees C: (i) artificial saliva based on Fusayama's solution (FS), (ii) artificial saliva with citric acid adjusted to pH 4.0 (FC) and (iii) 1% sodium chloride solution (SC). Corrosion potentials (E(corr)) and corrosion rates (I(corr)) were determined using potentiostatic and impedance spectroscopy methods. Data was subjected to anova/Scheffe's post hoc test at 0.05 significance level. For both alloys, the corrosion potential in FS was significantly greater than in SC. Corrosion potential of Tytin in FS and SC was also significantly greater than in FC. The corrosion rate of Dispersalloy in FC was significantly greater than in FS and SC. For Tytin, corrosion rate in SC was significantly greater than in FS and FC. Although no significant difference in corrosion potential/rate was observed between the alloys when tested in FS, significant differences were observed when electrochemical testing was carried out in FC and SC. The corrosion behaviour of high copper amalgam alloys are both material and environment dependent. Certain food substances may increase the corrosion of high copper amalgams.
Nocturnal oxygen saturation profiles of healthy term infants.
Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe
2015-01-01
Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Prospective longitudinal cohort study. Sleep-laboratory. 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Multi-functional sensor system for molten salt technologies
Redey, Laszlo [Downers Grove, IL; Gourishankar, Karthick [Downers Grove, IL; Williamson, Mark A [Naperville, IL
2009-12-15
The present invention relates to a multi-functional sensor system that simultaneously measures cathode and anode electrode potentials, dissolved ion (i.e. oxide) concentration, and temperatures in an electrochemical cell. One embodiment of the invented system generally comprises: a reference(saturated) electrode, a reference(sensing) electrode, and a data acquisition system. Thermocouples are built into the two reference electrodes to provide important temperature information.
Relation of electrochemical potentials and iron content to ground-water flow patterns
Back, William; Barnes, Ivan
1965-01-01
This study was undertaken to develop means of measuring oxidation potentials in aquifer systems and to use the measured values in interpreting the behavior of iron in ground water. Anne Arundel County, Md., was selected as the area of study because of the wide range of concentration of iron-nearly zero to about 35 ppm-in the ground water and the rather complete information on the geology and hydrology. The regional geology consists of coastal plain sediments ranging in age from Early Cretaceous through the Recent. Most of the pH and oxidation-potential measurements were made in nonmarine Cretaceous deposits, only a few in the marine Eocene. Iron-bearing minerals in the area are primarily hematite or limonite and glauconite with a small amount of pyrite. Equipment was developed that permits the measurement of oxidation potentials by use of saturated calomel and platinum electrodes in ground-water samples uncontaminated by oxygen of the atmosphere. Measured Eh values range from about +700 mv to -40 mv. Approximately 2 to 3 hours are required to measure a stable or nearly stable oxidation potential. The mineralogy and organic content of the deposits and the ground-water flow pattern are the primary controls on the oxidation potential and pH of the water. A correlation exists between the oxidation potential and the concentration of iron in ground water; the higher concentrations occur in waters with the lowest values of Eh. The concentration of iron in the water tested shows little correlation with the pH of the water. The highest oxidation potentials were measured in water produced from shallow wells and those wells in recharge areas. The lowest potentials were measured farthest downgradient in water associated with gray and green sediments. The Eh values measured in the field are between values predicted from the solubility of Fe(OH)2(c) and values predicted from the solubility of hematite.
Corrosion fatigue studies on a bulk glassy Zr-based alloy under three-point bending
NASA Astrophysics Data System (ADS)
Grell, Daniel; Wilkin, Yannic; Gostin, Petre F.; Gebert, Annett; Kerscher, Eberhard
2016-12-01
Corrosion fatigue (CF) tests were carried out on bulk glassy Zr52.5Cu17.9Al10Ni14.6Ti5 (Vitreloy 105) samples under load-controlled three-point bending conditions with a load ratio of R = 0.1 in 0.01 M Na2SO4 + 0.01 M NaCl electrolyte. During cyclic testing, the bar-shaped specimens were polarized in situ at constant potentials and the current was monitored. Three different anodic potentials within the interval between the pitting potential EP and the repassivation potential ER, and three different load amplitudes were applied. In some cases, in situ microscopic observations revealed the formation of black corrosion products in the vicinity of the crack tip during anodic polarization. Fractographic analysis revealed a clear distinction between two modes of crack growth characterized by smooth dissolution induced regions on the one hand and slim fast fracture areas on the other hand. Both alternating features contributed to a broad striated corrosion fatigue fracture surface. Moreover, further fatigue tests were carried out under free corrosion conditions yielding additional information on crack initiation and crack propagation period by means of the open circuit potential (OCP) changes. Thereby, a slight increase in OCP was detected after rupture of the passive layer due to bare metal exposed to the electrolyte. The electrochemical response increased continuously according to stable crack propagation until fracture occurred. Finally, the fracture surfaces of the corrosion fatigue samples were investigated by energy dispersive X-ray with the objective of analyzing the elemental distribution after anodic dissolution. Interestingly, anodic polarization at a near repassivation potential of -50 mV vs. SCE (Saturated Calomel Electrode, E = 0.241 V vs. SHE, Standard Hydrogen Electrode) led to favorable effects on the fatigue lifetime. In conclusion, all results are conflated to a corrosion fatigue model for bulk glassy Vitreloy 105 under anodic polarization in chloride-containing electrolyte and compared to the previously proposed stress corrosion mechanisms under similar conditions.
A Saturation Balancing Control Method for Enhancing Dynamic Vehicle Stability (PREPRINT)
2011-03-01
force estimation; axle saturation level; independent drive; torque biasing; 1. Introduction Vehicle stability control ( VSC ) systems have widely been...shown to reduce accidents by minimizing driver’s loss of control during aggressive emergency maneuvers. VSC systems manipulate one or more of the... VSC (also referred to as vehicle dynamics control (VDC)) systems available on the market today are brake-based systems which extend the functionality
Oh, Hea Lin; Lee, Jun Ah; Kim, Dong Ho; Lim, Jung Sub
2018-03-01
Ferritin reference values vary by age, gender, and ethnicity. We aimed to determine reference values of serum ferritin (SF) and the percentage of transferrin saturation (TSAT) for Korean children and adolescents. We analyzed data from 2,487 participants (1,311 males and 1,176 females) aged 10-20 years from the Korea National Health and Nutrition Examination Survey (2010-2012). We calculated age- and gender-stratified means and percentile values for SF and TSAT. We first plotted mean SF and TSAT by gender and according to age. In males, mean SF tended to be relatively constant among participants aged 10 to 14 years, with an upward trend thereafter. Mean SF trended downward among female participants until the age of 15 years and remained constant thereafter. Thus, significant gender differences in ferritin exist from the age of 14 years. High levels of SF were associated with obesity, and lower SF levels were associated with anemia and menarche status. We established reference values of SF and TSAT according to age and gender. The reference values for SF calculated in this study can be used to test the association between SF values and other defined diseases in Korean children and adolescents.
Mahar, Alyson L; Cobigo, Virginie; Stuart, Heather
2013-06-01
To develop a transdisciplinary conceptualization of social belonging that could be used to guide measurement approaches aimed at evaluating the effectiveness of community-based programs for people with disabilities. We conducted a narrative, scoping review of peer reviewed English language literature published between 1990 and July 2011 using multiple databases, with "sense of belonging" as a key search term. The search engine ranked articles for relevance to the search strategy. Articles were searched in order until theoretical saturation was reached. We augmented this search strategy by reviewing reference lists of relevant papers. Theoretical saturation was reached after 40 articles; 22 of which were qualitative accounts. We identified five intersecting themes: subjectivity; groundedness to an external referent; reciprocity; dynamism and self-determination. We define a sense of belonging as a subjective feeling of value and respect derived from a reciprocal relationship to an external referent that is built on a foundation of shared experiences, beliefs or personal characteristics. These feelings of external connectedness are grounded to the context or referent group, to whom one chooses, wants and feels permission to belong. This dynamic phenomenon may be either hindered or promoted by complex interactions between environmental and personal factors.
NASA Astrophysics Data System (ADS)
Sadeghipour, N.; Davis, S. C.; Tichauer, K. M.
2017-01-01
New precision medicine drugs oftentimes act through binding to specific cell-surface cancer receptors, and thus their efficacy is highly dependent on the availability of those receptors and the receptor concentration per cell. Paired-agent molecular imaging can provide quantitative information on receptor status in vivo, especially in tumor tissue; however, to date, published approaches to paired-agent quantitative imaging require that only ‘trace’ levels of imaging agent exist compared to receptor concentration. This strict requirement may limit applicability, particularly in drug binding studies, which seek to report on a biological effect in response to saturating receptors with a drug moiety. To extend the regime over which paired-agent imaging may be used, this work presents a generalized simplified reference tissue model (GSRTM) for paired-agent imaging developed to approximate receptor concentration in both non-receptor-saturated and receptor-saturated conditions. Extensive simulation studies show that tumor receptor concentration estimates recovered using the GSRTM are more accurate in receptor-saturation conditions than the standard simple reference tissue model (SRTM) (% error (mean ± sd): GSRTM 0 ± 1 and SRTM 50 ± 1) and match the SRTM accuracy in non-saturated conditions (% error (mean ± sd): GSRTM 5 ± 5 and SRTM 0 ± 5). To further test the approach, GSRTM-estimated receptor concentration was compared to SRTM-estimated values extracted from tumor xenograft in vivo mouse model data. The GSRTM estimates were observed to deviate from the SRTM in tumors with low receptor saturation (which are likely in a saturated regime). Finally, a general ‘rule-of-thumb’ algorithm is presented to estimate the expected level of receptor saturation that would be achieved in a given tissue provided dose and pharmacokinetic information about the drug or imaging agent being used, and physiological information about the tissue. These studies suggest that the GSRTM is necessary when receptor saturation exceeds 20% and highlight the potential for GSRTM to accurately measure receptor concentrations under saturation conditions, such as might be required during high dose drug studies, or for imaging applications where high concentrations of imaging agent are required to optimize signal-to-noise conditions. This model can also be applied to PET and SPECT imaging studies that tend to suffer from noisier data, but require one less parameter to fit if images are converted to imaging agent concentration (quantitative PET/SPECT).
Photosystem Inspired Peptide Hybrid Catalysts
2017-06-07
greenhouse gas , CO2 also can be an abundant C1 feedstock. Inspired by biological enzyme system, especially dehydrogenase catalyzing CO2 reduction...utilizing a potentiostat and converted to the RHE reference scale. Typically, before the electrolysis, the catholyte was saturated with CO2 gas for at...least 15 min to satisfy the saturation of pH. When the passed charge runs to 5 C, the electrolysis was stopped. Then, gas products were sampled using a
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children
Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young
2016-01-01
Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young
2016-09-01
Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Yong-Feng Gao; Xi-Ming Sun; Changyun Wen; Wei Wang
2017-07-01
This paper is concerned with the problem of adaptive tracking control for a class of uncertain nonlinear systems with nonsymmetric input saturation and immeasurable states. The radial basis function of neural network (NN) is employed to approximate unknown functions, and an NN state observer is designed to estimate the immeasurable states. To analyze the effect of input saturation, an auxiliary system is employed. By the aid of adaptive backstepping technique, an adaptive tracking control approach is developed. Under the proposed adaptive tracking controller, the boundedness of all the signals in the closed-loop system is achieved. Moreover, distinct from most of the existing references, the tracking error can be bounded by an explicit function of design parameters and saturation input error. Finally, an example is given to show the effectiveness of the proposed method.
Oxygen Breathing Accelerates Decompression from Saturation at 40 msw in 70-kg Swine
2010-07-01
2010 0 2 AFfER A DEEP SATURATION DIVE-PETERSEN ET AL. REFERENCES 1. Bain SA, Tmg J, Simeonovic CJ, Wilson JO. Technique of venous catheterization ...was catheterized with a 16-gauge by 20.3-cm single lumen catheter (Braun Certofix; B. Braun Medical Inc., Bethlehem, PA) via the modified Seldinger...respiratory distress, as evidenced by open-mouthed, labored breathing, central cyanosis, or the production of frothy white sputum. The onset of se- vere
Video monitoring of oxygen saturation during controlled episodes of acute hypoxia.
Addison, Paul S; Foo, David M H; Jacquel, Dominique; Borg, Ulf
2016-08-01
A method for extracting video photoplethysmographic information from an RGB video stream is tested on data acquired during a porcine model of acute hypoxia. Cardiac pulsatile information was extracted from the acquired signals and processed to determine a continuously reported oxygen saturation (SvidO2). A high degree of correlation was found to exist between the video and a reference from a pulse oximeter. The calculated mean bias and accuracy across all eight desaturation episodes were -0.03% (range: -0.21% to 0.24%) and accuracy 4.90% (range: 3.80% to 6.19%) respectively. The results support the hypothesis that oxygen saturation trending can be evaluated accurately from a video system during acute hypoxia.
Wang, Liqin; Bray, Bruce E.; Shi, Jianlin; Fiol, Guilherme Del; Haug, Peter J.
2017-01-01
Objective Disease-specific vocabularies are fundamental to many knowledge-based intelligent systems and applications like text annotation, cohort selection, disease diagnostic modeling, and therapy recommendation. Reference standards are critical in the development and validation of automated methods for disease-specific vocabularies. The goal of the present study is to design and test a generalizable method for the development of vocabulary reference standards from expert-curated, disease-specific biomedical literature resources. Methods We formed disease-specific corpora from literature resources like textbooks, evidence-based synthesized online sources, clinical practice guidelines, and journal articles. Medical experts annotated and adjudicated disease-specific terms in four classes (i.e., causes or risk factors, signs or symptoms, diagnostic tests or results, and treatment). Annotations were mapped to UMLS concepts. We assessed source variation, the contribution of each source to build disease-specific vocabularies, the saturation of the vocabularies with respect to the number of used sources, and the generalizability of the method with different diseases. Results The study resulted in 2588 string-unique annotations for heart failure in four classes, and 193 and 425 respectively for pulmonary embolism and rheumatoid arthritis in treatment class. Approximately 80% of the annotations were mapped to UMLS concepts. The agreement among heart failure sources ranged between 0.28 and 0.46. The contribution of these sources to the final vocabulary ranged between 18% and 49%. With the sources explored, the heart failure vocabulary reached near saturation in all four classes with the inclusion of minimal six sources (or between four to seven sources if only counting terms occurred in two or more sources). It took fewer sources to reach near saturation for the other two diseases in terms of the treatment class. Conclusions We developed a method for the development of disease-specific reference vocabularies. Expert-curated biomedical literature resources are substantial for acquiring disease-specific medical knowledge. It is feasible to reach near saturation in a disease-specific vocabulary using a relatively small number of literature sources. PMID:26971304
Prietzel, Jörg; Harrington, Gertraud; Häusler, Werner; Heister, Katja; Werner, Florian; Klysubun, Wantana
2016-03-01
Direct speciation of soil phosphorus (P) by linear combination fitting (LCF) of P K-edge XANES spectra requires a standard set of spectra representing all major P species supposed to be present in the investigated soil. Here, available spectra of free- and cation-bound inositol hexakisphosphate (IHP), representing organic P, and of Fe, Al and Ca phosphate minerals are supplemented with spectra of adsorbed P binding forms. First, various soil constituents assumed to be potentially relevant for P sorption were compared with respect to their retention efficiency for orthophosphate and IHP at P levels typical for soils. Then, P K-edge XANES spectra for orthophosphate and IHP retained by the most relevant constituents were acquired. The spectra were compared with each other as well as with spectra of Ca, Al or Fe orthophosphate and IHP precipitates. Orthophosphate and IHP were retained particularly efficiently by ferrihydrite, boehmite, Al-saturated montmorillonite and Al-saturated soil organic matter (SOM), but far less efficiently by hematite, Ca-saturated montmorillonite and Ca-saturated SOM. P retention by dolomite was negligible. Calcite retained a large portion of the applied IHP, but no orthophosphate. The respective P K-edge XANES spectra of orthophosphate and IHP adsorbed to ferrihydrite, boehmite, Al-saturated montmorillonite and Al-saturated SOM differ from each other. They also are different from the spectra of amorphous FePO4, amorphous or crystalline AlPO4, Ca phosphates and free IHP. Inclusion of reference spectra of orthophosphate as well as IHP adsorbed to P-retaining soil minerals in addition to spectra of free or cation-bound IHP, AlPO4, FePO4 and Ca phosphate minerals in linear combination fitting exercises results in improved fit quality and a more realistic soil P speciation. A standard set of P K-edge XANES spectra of the most relevant adsorbed P binding forms in soils is presented.
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Pichler, Gerhard; Binder, Corinna; Avian, Alexander; Beckenbach, Elisabeth; Schmölzer, Georg M; Urlesberger, Berndt
2013-12-01
To define reference ranges for regional cerebral tissue oxygen saturation (crSO2) and regional cerebral fractional tissue oxygen extraction (cFTOE) during the first 15 minutes after birth in neonates requiring no medical support. The crSO2 was measured using near infrared spectroscopy (Invos 5100 cerebral/somatic oximeter monitor; Somanetics Corp, Troy, Michigan) during the first 15 minutes after birth for term and preterm neonates. The near infrared spectroscopy sensor was placed on the left forehead. Peripheral oxygen saturation and heart rate were continuously measured by pulse oximetry, and cFTOE was calculated. Neonates were excluded if they required any medical support. A total of 381 neonates were included: 82 term neonates after vaginal delivery, 272 term neonates after cesarean delivery, and 27 preterm neonates after cesarean delivery. In all neonates, median (10th-90th percentiles) crSO2 was 41% (23-64) at 2 minutes, 68% (45-85) at 5 minutes, 79% (65-90) at 10 minutes, and 77% (63-89) at 15 minutes of age. In all neonates, median (10th-90th percentiles) cFTOE was 33% (11-70) at 2 minutes, 21% (6-45) at 5 minutes, 15% (5-31) at 10 minutes, and 18% (7-34) at 15 minutes of age. We report reference ranges of crSO2 and cFTOE in neonates requiring no medical support during transition immediately after birth. The use of cerebral oxygenation monitoring and use of these reference ranges in neonates during transition may help to guide oxygen delivery and avoid cerebral hypo-oxygenation and hyperoxygenation. Copyright © 2013 Mosby, Inc. All rights reserved.
Retinal vessel oxygen saturation in a healthy young Chinese population.
Yang, Wei; Fu, Yue; Dong, Yanmin; Lin, Leilei; Huang, Xia; Li, Yujie; Lin, Xiaofeng; Gao, Qianying
2016-06-01
To measure retinal vessel oxygen saturation in a healthy young Chinese population and to determine the effects of multiple factors (gender, age, dioptre, vessel diameter and ocular perfusion pressure - OPP) on retinal oxygen saturation. A total of 126 healthy Chinese individuals aged from 19 to 30 were included in this study. A retinal oximeter (Oxymap T1) was used to measure retinal vessel oxygen saturation by retinal imaging at two different wavelengths. The mean retinal vessel oxygen saturation (Sat_O2 ) of arterioles, venules and arteriovenous (AV) difference overall and in four separate quadrants were measured. Intra-ocular pressure, blood pressure, finger pulse oximetry value, vessel diameter and dioptre were also measured. The correlations between OPP and dioptre, OPP and vessel diameter, and dioptre and vessel diameter were analysed. And the effects of multiple factors on the retinal oxygen saturation were analysed. The mean oxygen saturation was 93.2 ± 6.3% in the retinal arterioles, 60.4 ± 5.3% in venules and 32.9 ± 6.4% in AV difference. The temporal quadrants had lower measurements of arteriolar and venular oxygen saturation and AV difference compared with nasal quadrants (p < 0.001). The oxygen saturation of the arterioles, venules and AV difference were unaffected by any unique factor. Arteriolar and venular retinal oxygen saturation correlated negatively with the product of dioptre and OPP. Arteriolar retinal oxygen saturation correlated positively with the product of dioptre and vessel diameter. This study provided a normal reference of Sat_O2 in healthy young Chinese individuals. It was a reflection of the normal state of retinal oxygen metabolism affected by several factors. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Abell, J. T.; Jacobsen, J.; Bjorkstedt, E.
2016-02-01
Determining aragonite saturation state (Ω) in seawater requires measurement of two parameters of the carbonate system: most commonly dissolved inorganic carbon (DIC) and total alkalinity (TA). The routine measurement of DIC and TA is not always possible on frequently repeated hydrographic lines or at moored-time series that collect hydrographic data at short time intervals. In such cases a proxy can be developed that relates the saturation state as derived from one time or infrequent DIC and TA measurements (Ωmeas) to more frequently measured parameters such as dissolved oxygen (DO) and temperature (Temp). These proxies are generally based on best-fit parameterizations that utilize references values of DO and Temp and adjust linear coefficients until the error between the proxy-derived saturation state (Ωproxy) and Ωmeas is minimized. Proxies have been used to infer Ω from moored hydrographic sensors and gliders which routinely collect DO and Temp data but do not include carbonate parameter measurements. Proxies can also calculate Ω in regional oceanographic models which do not explicitly include carbonate parameters. Here we examine the variability and accuracy of Ωproxy along a near-shore hydrographic line and a moored-time series stations at Trinidad Head, CA. The saturation state is determined using proxies from different coastal regions of the California Current Large Marine Ecosystem and from different years of sampling along the hydrographic line. We then calculate the variability and error associated with the use of different proxy coefficients, the sensitivity to reference values and the inclusion of additional variables. We demonstrate how this variability affects estimates of the intensity and duration of exposure to aragonite corrosive conditions on the near-shore shelf and in the water column.
Wang, Huanqing; Chen, Bing; Liu, Xiaoping; Liu, Kefu; Lin, Chong
2013-12-01
This paper is concerned with the problem of adaptive fuzzy tracking control for a class of pure-feedback stochastic nonlinear systems with input saturation. To overcome the design difficulty from nondifferential saturation nonlinearity, a smooth nonlinear function of the control input signal is first introduced to approximate the saturation function; then, an adaptive fuzzy tracking controller based on the mean-value theorem is constructed by using backstepping technique. The proposed adaptive fuzzy controller guarantees that all signals in the closed-loop system are bounded in probability and the system output eventually converges to a small neighborhood of the desired reference signal in the sense of mean quartic value. Simulation results further illustrate the effectiveness of the proposed control scheme.
Helms, Gunther; Dathe, Henning; Kallenberg, Kai; Dechent, Peter
2008-12-01
An empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH, introducing a novel semiquantitative parameter for MT, the percentage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T(1) weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging at 3 T was based on nonselective sagittal 3D-FLASH at 1.25 mm isotropic resolution using partial acquisition techniques (TR/TE/alpha = 25ms/4.9ms/5 degrees or 11ms/4.9ms/15 degrees for the T(1) reference). A 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540 degrees flip angle. The MT saturation maps showed an excellent contrast in the brain due to clearly separated distributions for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15 degrees , TR/T(1) less sign 1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T(1) relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter. (c) 2008 Wiley-Liss, Inc.
Saturation pulse design for quantitative myocardial T1 mapping.
Chow, Kelvin; Kellman, Peter; Spottiswoode, Bruce S; Nielles-Vallespin, Sonia; Arai, Andrew E; Salerno, Michael; Thompson, Richard B
2015-10-01
Quantitative saturation-recovery based T1 mapping sequences are less sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) technique but require high performance saturation pulses. We propose to optimize adiabatic and pulse train saturation pulses for quantitative T1 mapping to have <1 % absolute residual longitudinal magnetization (|MZ/M0|) over ranges of B0 and [Formula: see text] (B1 scale factor) inhomogeneity found at 1.5 T and 3 T. Design parameters for an adiabatic BIR4-90 pulse were optimized for improved performance within 1.5 T B0 (±120 Hz) and [Formula: see text] (0.7-1.0) ranges. Flip angles in hard pulse trains of 3-6 pulses were optimized for 1.5 T and 3 T, with consideration of T1 values, field inhomogeneities (B0 = ±240 Hz and [Formula: see text]=0.4-1.2 at 3 T), and maximum achievable B1 field strength. Residual MZ/M0 was simulated and measured experimentally for current standard and optimized saturation pulses in phantoms and in-vivo human studies. T1 maps were acquired at 3 T in human subjects and a swine using a SAturation recovery single-SHot Acquisition (SASHA) technique with a standard 90°-90°-90° and an optimized 6-pulse train. Measured residual MZ/M0 in phantoms had excellent agreement with simulations over a wide range of B0 and [Formula: see text]. The optimized BIR4-90 reduced the maximum residual |MZ/M0| to <1 %, a 5.8× reduction compared to a reference BIR4-90. An optimized 3-pulse train achieved a maximum residual |MZ/M0| <1 % for the 1.5 T optimization range compared to 11.3 % for a standard 90°-90°-90° pulse train, while a 6-pulse train met this target for the wider 3 T ranges of B0 and [Formula: see text]. The 6-pulse train demonstrated more uniform saturation across both the myocardium and entire field of view than other saturation pulses in human studies. T1 maps were more spatially homogeneous with 6-pulse train SASHA than the reference 90°-90°-90° SASHA in both human and animal studies. Adiabatic and pulse train saturation pulses optimized for different constraints found at 1.5 T and 3 T achieved <1 % residual |MZ/M0| in phantom experiments, enabling greater accuracy in quantitative saturation recovery T1 imaging.
All-optical associative memory using photorefractive crystals and a saturable absorber
NASA Astrophysics Data System (ADS)
Duelli, Markus; Cudney, Roger S.; Keller, Claude; Guenter, Peter
1995-07-01
We report on the investigation of a new configuration of an all-optical associative memory. The images to be recalled associatively are stored in a LiNbO3 crystal via angular multiplexing. Thresholding of the reconstructed reference beams during associative readout is achieved by using a saturable absorber with an intensity-tunable threshold. We demonstrate associative readout and error correction for 10 strongly overlapping black-and-white images. Associative recall and full reconstruction is performed when only 1/500 of the image stored is entered.
NASA Astrophysics Data System (ADS)
Yu, Xuelian; Chen, Qian; Gu, Guohua; Ren, Jianle; Sui, Xiubao
2015-02-01
Designing objective quality assessment of color-fused image is a very demanding and challenging task. We propose four no-reference metrics based on human visual system characteristics for objectively evaluating the quality of false color fusion image. The perceived edge metric (PEM) is defined based on visual perception model and color image gradient similarity between the fused image and the source images. The perceptual contrast metric (PCM) is established associating multi-scale contrast and varying contrast sensitivity filter (CSF) with color components. The linear combination of the standard deviation and mean value over the fused image construct the image colorfulness metric (ICM). The color comfort metric (CCM) is designed by the average saturation and the ratio of pixels with high and low saturation. The qualitative and quantitative experimental results demonstrate that the proposed metrics have a good agreement with subjective perception.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wasan, D.T.
The relative permeability model for two phase flow in porous media (Wasan 1983; Ramakrishnan and Wasan 1984) provides the necessary fractional flow curves at a given capillary number. These curves can be utilized in modeling both enhanced secondary and tertiary recovery processes. Important parameters in the fractional flow curves of our relative permeability model are the residual wetting and nonwetting phase saturations in a low capillary number flooding process. To understand, what constitutes the residual saturations, this quarter we have studied the displacement of one incompressible fluid by another in a porous medium using the network representation. The Bernoulli percolationmore » model for an infinite lattice graph is utilized in the interpretation of the capillary behavior of the medium, which ultimately determines residual saturations. The calculated capillary pressure-saturation relationship using Bethe lattice results agrees qualitatively with experimental data. 4 references, 2 figures.« less
Design of feedback control systems for stable plants with saturating actuators
NASA Technical Reports Server (NTRS)
Kapasouris, Petros; Athans, Michael; Stein, Gunter
1988-01-01
A systematic control design methodology is introduced for multi-input/multi-output stable open loop plants with multiple saturations. This new methodology is a substantial improvement over previous heuristic single-input/single-output approaches. The idea is to introduce a supervisor loop so that when the references and/or disturbances are sufficiently small, the control system operates linearly as designed. For signals large enough to cause saturations, the control law is modified in such a way as to ensure stability and to preserve, to the extent possible, the behavior of the linear control design. Key benefits of the methodology are: the modified compensator never produces saturating control signals, integrators and/or slow dynamics in the compensator never windup, the directional properties of the controls are maintained, and the closed loop system has certain guaranteed stability properties. The advantages of the new design methodology are illustrated in the simulation of an academic example and the simulation of the multivariable longitudinal control of a modified model of the F-8 aircraft.
Dynamic Determination of Oxygenation and Lung Compliance in Murine Pneumonectomy
Gibney, Barry; Lee, Grace S.; Houdek, Jan; Lin, Miao; Miele, Lino; Chamoto, Kenji; Konerding, Moritz A.; Tsuda, Akira; Mentzer, Steven J.
2012-01-01
Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, we investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55–82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10ml/kg. Sustained inflation pressures, referred to as a "recruitment maneuver," improved lung volumes, lung compliance and arterial oxygenation. In contrast, positive end expiratory pressure (PEEP) had a detrimental effect on oxygenation; an effect that was ameliorated after pneumonectomy. Our results confirm that lung volumes in the mouse are dynamically determined and suggest a threshold level of mechanical ventilation to maintain perioperative oxygen saturation. PMID:21574875
NASA Astrophysics Data System (ADS)
Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David
2018-01-01
To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass accommodation coefficient and some not) suggests that the mass accommodation coefficients of the studied compounds are close to unity. The quantum chemistry calculations were about 1 order of magnitude higher than the measurements. We find that extrapolation of vapor pressures from elevated to atmospheric temperatures is permissible over a range of about 100 K for these compounds, suggesting that measurements should be performed best at temperatures yielding the highest-accuracy data, allowing subsequent extrapolation to atmospheric temperatures.
Siega-Riz, Anna Maria; Haugen, Margaretha; Meltzer, Helle M; Von Holle, Ann; Hamer, Robert; Torgersen, Leila; Knopf-Berg, Cecilie; Reichborn-Kjennerud, Ted; Bulik, Cynthia M
2009-01-01
Background Little is known concerning the dietary habits of eating disordered women during pregnancy that may lie in the causal pathway of adverse birth outcomes. Objective To examine the nutrient and food group intake of women with bulimia nervosa (BN) and binge eating disorder (BED) during pregnancy and compare their intake to women with no eating disorders. Design Data on 30,040 mother-child pairs are from the prospective Norwegian Mother and Child Cohort Study was used in cross-sectional analyses. Dietary information was collected using a food frequency questionnaire during the first half of pregnancy. Statistical testing by eating disorder categories with the non-eating disorder category as the referent group were conducted using log (means) adjusted for confounding and multiple comparisons. Food group differences were conducted using a Wilcoxon two-sided normal approximation test also adjusting for multiple comparisons. Results Women with BED before and during pregnancy had higher intakes of total energy, total mono-saturated and saturated fat, and lower intakes of folate, potassium, and vitamin C compared to the referent (p<.02). Women with incident BED during pregnancy had higher total energy and saturated fat intake compared to the referent (p=.01). Several differences emerged in food group consumption between women with and without eating disorders including intakes of artificial sweeteners, sweets, juice, fruits and fats. Conclusions Women with BN before and during pregnancy and those with BED before pregnancy exhibit dietary patterns different from women without eating disorders, that are reflective of their symptomatology, and may influence pregnancy outcomes. PMID:18469258
Chatterjee, Sudip K; Roy, Suprakash; Barman, Suman Kumar; Maji, Ram Chandra; Olmstead, Marilyn M; Patra, Apurba K
2012-07-16
Seven bis-Ni(II) complexes of a N(2)S donor set ligand have been synthesized and examined for their ability to stabilize Ni(0), Ni(I), Ni(II) and Ni(III) oxidation states. Compounds 1-5 consist of modifications of the pyridine ring of the tridentate Schiff base ligand, 2-pyridyl-N-(2'-methylthiophenyl)methyleneimine ((X)L1), where X = 6-H, 6-Me, 6-p-ClPh, 6-Br, 5-Br; compound 6 is the reduced amine form (L2); compound 7 is the amide analog (L3). The compounds are perchlorate salts except for 7, which is neutral. Complexes 1 and 3-7 have been structurally characterized. Their coordination geometry is distorted octahedral. In the case of 6, the tridentate ligand coordinates in a facial manner, whereas the remaining complexes display meridional coordination. Due to substitution of the pyridine ring of (X)L1, the Ni-N(py) distances for 1~5 < 3 < 4 increase and UV-vis λ(max) values corresponding to the (3)A(2g)(F)→(3)T(2g)(F) transition show an increasing trend 1~5 < 2 < 3 < 4. Cyclic voltammetry of 1-5 reveals two quasi-reversible reduction waves that correspond to Ni(II)→Ni(I) and Ni(I)→Ni(0) reduction. The E(1/2) for the Ni(II)/Ni(I) couple decreases as 1 > 2 > 3 > 4. Replacement of the central imine N donor in 1 by amine 6 or amide 7 N donors reveals that complex 6 in CH(3)CN exhibits an irreversible reductive response at E(pc) = -1.28 V, E(pa) = +0.25 V vs saturated calomel electrode (SCE). In contrast, complex 7 shows a reversible oxidation wave at E(1/2) = +0.84 V (ΔE(p) = 60 mV) that corresponds to Ni(II)→Ni(III). The electrochemically generated Ni(III) species, [(L3)(2)Ni(III)](+) is stable, showing a new UV-vis band at 470 nm. EPR measurements have also been carried out.
Li, Liang; Liang, Bo; Li, Feng; Shi, Jianguo; Mascini, Marco; Lang, Qiaolin; Liu, Aihua
2013-04-15
In this paper, we first report the construction of Nafion/glucose oxidase (GOD)/xylose dehydrogenase displayed bacteria (XDH-bacteria)/multiwalled carbon nanotubes (MWNTs) modified electrode for simultaneous voltammetric determination of D-glucose and D-xylose. The optimal conditions for the immobilized enzymes were established. Both enzymes retained their good stability and activities. In the mixture solution of D-glucose and D-xylose containing coenzyme NAD⁺ (the oxidized form of nicotinamide adenine dinucleotide), the Nafion/GOD/XDH-bacteria/MWNTs modified electrode exhibited quasi-reversible oxidation-reduction peak at -0.5 V (vs. saturated calomel electrode, SCE) originating from the catalytic oxidation of D-glucose, and oxidation peak at +0.55 V(vs. SCE) responding to the oxidation of NADH (the reduced form of nicotinamide adenine dinucleotide) by the carbon nanotubes, where NADH is the resultant product of coenzyme NAD⁺ involved in the catalysis of D-xylose by XDH-displayed bacteria. For the proposed biosensor, cathodic peak current at -0.5 V was linear with the concentration of D-glucose within the range of 0.25-6 mM with a low detection limit of 0.1 mM D-glucose (S/N=3), and the anodic peak current at +0.55 V was linear with the concentration of d-xylose in the range of 0.25∼4 mM with a low detection limit of 0.1 mM D-xylose (S/N=3). Further, D-xylose and D-glucose did not interfere with each other. 300-fold excess saccharides including D-maltose, D-galactose, D-mannose, D-sucrose, D-fructose, D-cellobiose, and 60-fold excess L-arabinose, and common interfering substances (100-fold excess ascorbic acid, dopamine, uric acid) as well as 300-fold excess D-xylitol did not affect the detection of D-glucose and D-xylose (both 1 mM). Therefore, the proposed biosensor is stable, specific, reproducible, simple, rapid and cost-effective, which holds great potential in real applications. Copyright © 2012 Elsevier B.V. All rights reserved.
Hosseini, Soraya; Jahangirian, Hossein; Webster, Thomas J; Soltani, Salman Masoudi; Aroua, Mohamed Kheireddine
2016-01-01
Nanostructured photoanodes were prepared via a novel combination of titanium dioxide (TiO2) nanoparticles and mesoporous carbon (C). Four different photoanodes were synthesized by sol-gel spin coating onto a glassy substrate of fluorine-doped tin oxide. The photocatalytic activities of TiO2, TiO2/C/TiO2, TiO2/C/C/TiO2, and TiO2/C/TiO2/C/TiO2 photoanodes were evaluated by exposing the synthesized photoanodes to UV-visible light. The photocurrent density observed in these photoanodes confirmed that an additional layer of mesoporous carbon could successfully increase the photocurrent density. The highest photocurrent density of ~1.022 mA cm(-2) at 1 V/saturated calomel electrode was achieved with TiO2/C/C/TiO2 under an illumination intensity of 100 mW cm(-2) from a solar simulator. The highest value of surface roughness was measured for a TiO2/C/C/TiO2 combination owing to the presence of two continuous layers of mesoporous carbon. The resulting films had a thickness ranging from 1.605 µm to 5.165 µm after the calcination process. The presence of double-layer mesoporous carbon resulted in a 20% increase in the photocurrent density compared with the TiO2/C/TiO2 combination when only a single mesoporous carbon layer was employed. The improved performance of these photoanodes can be attributed to the enhanced porosity and increased void space due to the presence of mesoporous carbon. For the first time, it has been demonstrated here that the photoelectrochemical performance of TiO2 can be improved by integrating several layers of mesoporous carbon. Comparison of the rate of removal of humic acid by the prepared photoanodes showed that the highest performance from TiO2/C/C/TiO2 was due to the highest photocurrent density generated. Therefore, this study showed that optimizing the sequence of mesoporous carbon layers can be a viable and inexpensive method for enhanced humic acid removal.
Hosseini, Soraya; Jahangirian, Hossein; Webster, Thomas J; Soltani, Salman Masoudi; Aroua, Mohamed Kheireddine
2016-01-01
Nanostructured photoanodes were prepared via a novel combination of titanium dioxide (TiO2) nanoparticles and mesoporous carbon (C). Four different photoanodes were synthesized by sol–gel spin coating onto a glassy substrate of fluorine-doped tin oxide. The photocatalytic activities of TiO2, TiO2/C/TiO2, TiO2/C/C/TiO2, and TiO2/C/TiO2/C/TiO2 photoanodes were evaluated by exposing the synthesized photoanodes to UV–visible light. The photocurrent density observed in these photoanodes confirmed that an additional layer of mesoporous carbon could successfully increase the photocurrent density. The highest photocurrent density of ~1.022 mA cm−2 at 1 V/saturated calomel electrode was achieved with TiO2/C/C/TiO2 under an illumination intensity of 100 mW cm−2 from a solar simulator. The highest value of surface roughness was measured for a TiO2/C/C/TiO2 combination owing to the presence of two continuous layers of mesoporous carbon. The resulting films had a thickness ranging from 1.605 µm to 5.165 µm after the calcination process. The presence of double-layer mesoporous carbon resulted in a 20% increase in the photocurrent density compared with the TiO2/C/TiO2 combination when only a single mesoporous carbon layer was employed. The improved performance of these photoanodes can be attributed to the enhanced porosity and increased void space due to the presence of mesoporous carbon. For the first time, it has been demonstrated here that the photoelectrochemical performance of TiO2 can be improved by integrating several layers of mesoporous carbon. Comparison of the rate of removal of humic acid by the prepared photoanodes showed that the highest performance from TiO2/C/C/TiO2 was due to the highest photocurrent density generated. Therefore, this study showed that optimizing the sequence of mesoporous carbon layers can be a viable and inexpensive method for enhanced humic acid removal. PMID:27574426
Oxygen saturation in the dental pulp of permanent teeth: a critical review.
Bruno, Kely Firmino; Barletta, Fernando Branco; Felippe, Wilson Tadeu; Silva, Júlio Almeida; Gonçalves de Alencar, Ana Helena; Estrela, Carlos
2014-08-01
Pulse oximetry is a noninvasive method for assessing vascular health based on oxygen saturation level. The method has recently also been used to assess dental pulp vitality, but a median oxygen saturation level suggestive of normal pulp physiology has not been determined. The objective of this study was to make a critical analysis of the published research to establish the median oxygen saturation for the diagnosis of normal dental pulps in maxillary anterior permanent teeth using pulse oximetry. Studies reporting on the use of pulse oximeters to determine oxygen saturation in dental pulps were retrieved using the MEDLINE, Scientific Electronic Library Online, and Cochrane Central Register of Controlled Trials databases plus a manual search of relevant references cited by selected articles. Different combinations of the terms "oximetry," "oximeter," "pulp," "dental," and "dentistry" were used in the search. Statistical analysis was performed for each group of teeth (central incisors, lateral incisors, and canines) using R statistical software (US EPA ORD NHEERL, Corvallis, OR) and a random effects model (P < .0001) with an I(2) of 99%. Of the 295 articles found, only 6 met the inclusion criteria (472 teeth). Of these, the number of articles included in each analysis (according to tooth group) was as follows: all 6 studies (288 teeth) for central incisors at a median oxygen saturation of 87.73%, 3 studies (90 teeth) for lateral incisors at a median oxygen saturation of 87.24%, and 4 studies (94 teeth) for canines at a median oxygen saturation of 87.26%. The median oxygen saturation in normal dental pulps of permanent central incisors, lateral incisors, and canines was higher than 87%. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Oxygen saturation in optic nerve head structures by hyperspectral image analysis.
Beach, James; Ning, Jinfeng; Khoobehi, Bahram
2007-02-01
A method is presented for the calculation and visualization of percent blood oxygen saturation from specific tissue structures in hyperspectral images of the optic nerve head (ONH). Trans-pupillary images of the primate optic nerve head and overlying retinal blood vessels were obtained with a hyperspectral imaging (HSI) system attached to a fundus camera. Images were recorded during normal blood flow and after partially interrupting flow to the ONH and retinal circulation by elevation of the intraocular pressure (IOP) from 10 mmHg to 55 mmHg in steps. Percent oxygen saturation was calculated from groups of pixels associated with separate tissue structures, using a linear least-squares curve fit of the recorded hemoglobin spectrum to reference spectra obtained from fully oxygenated and deoxygenated red cell suspensions. Color maps of saturation were obtained from a new algorithm that enables comparison of oxygen saturation from large vessels and tissue areas in hyperspectral images. Percent saturation in retinal vessels and from the average over ONH structures (IOP = 10 mmHg) was (mean +/- SE): artery 81.8 +/- 0.4%, vein 42.6 +/- 0.9%, average ONH 68.3 +/- 0.4%. Raising IOP from 10 mmHg to 55 mmHg for 5 min caused blood oxygen saturation to decrease (mean +/- SE): artery 46.1 +/- 6.2%, vein 36.1 +/- 1.6%, average ONH 41.9 +/- 1.6%. The temporal cup showed the highest saturation at low and high IOP (77.3 +/- 1.0% and 60.1 +/- 4.0%) and the least reduction in saturation at high IOP (22.3%) compared with that of the average ONH (38.6%). A linear relationship was found between saturation indices obtained from the algorithm and percent saturation values obtained by spectral curve fits to calibrated red cell samples. Percent oxygen saturation was determined from hyperspectral images of the ONH tissue and retinal vessels overlying the ONH at normal and elevated IOP. Pressure elevation was shown to reduce blood oxygen saturation in vessels and ONH structures, with the smallest reduction in the ONH observed in the temporal cup. IOP-induced saturation changes were visualized in color maps using an algorithm that follows saturation-dependent changes in the blood spectrum and blood volume differences across tissue. Reduced arterial saturation at high IOP may have resulted from a flow-dependent mechanism.
Yang, Haifeng; Liu, Yanli; Liu, Zhimin; Yang, Yu; Jiang, Jianhui; Zhang, Zongrang; Shen, Guoli; Yu, Ruqin
2005-02-24
The self-assembled monolayers (SAMs) of 6-mercaptopurine (6MP) were formed at the roughened polycrystalline gold surfaces in acid and alkaline media. The time-dependent Raman mapping spectral analysis in conjunction with the quantum calculations for the vibrational modes using ab initio BLYP/6-31G method suggested that both of the resulted 6MP SAMs adopted the same adsorption mode through the S atom of pyrimidine moiety and the N7 atom of the imidazole moiety anchoring the gold surface in a vertical way. The in situ surface-enhanced Raman scattering spectroelectrochemical experiment was conducted to examine the stability of the SAMs at various bias potentials. It was found that the detaching process of the 6MP SAMs from the surface involved one electron reduction as the voltage was applied at ca. 0.7 V vs a standard calomel electrode.
Burke, Nicole; Golas, Mitchell; Raafat, Cyrus L.
2015-01-01
The puzzle of a mysterious death in the Middle Ages has been hypothesized in terms of contemporary forensic legal and scientific methods. That al-Hasan ibn-‘Ali died in 669 aged just 45 has been forensically analyzed based on written sources that dictate eyewitness accounts of historical events. The report of the contemporaneous poisoning of another individual who resided under the same household as al-Hasan’s and experienced similar, yet non-lethal, symptoms has served as the beginning of the analysis. In light of ancient (medieval) documents and through using mineralogical, medical, and chemical facts, it has been hypothesized that mineral calomel (mercury(I) chloride, Hg2Cl2) from a certain region in the Byzantine Empire (present-day western Turkey) was the substance primarily responsible for the murder of al-Hasan. PMID:26377933
NASA Technical Reports Server (NTRS)
Kapasouris, Petros
1988-01-01
A systematic control design methodology is introduced for multi-input/multi-output systems with multiple saturations. The methodology can be applied to stable and unstable open loop plants with magnitude and/or rate control saturations and to systems in which state limitations are desired. This new methodology is a substantial improvement over previous heuristic single-input/single-output approaches. The idea is to introduce a supervisor loop so that when the references and/or disturbances are sufficiently small, the control system operates linearly as designed. For signals large enough to cause saturations, the control law is modified in such a way to ensure stability and to preserve, to the extent possible, the behavior of the linear control design. Key benefits of this methodology are: the modified compensator never produces saturating control signals, integrators and/or slow dynamics in the compensator never windup, the directional properties of the controls are maintained, and the closed loop system has certain guaranteed stability properties. The advantages of the new design methodology are illustrated by numerous simulations, including the multivariable longitudinal control of modified models of the F-8 (stable) and F-16 (unstable) aircraft.
State reference design and saturated control of doubly-fed induction generators under voltage dips
NASA Astrophysics Data System (ADS)
Tilli, Andrea; Conficoni, Christian; Hashemi, Ahmad
2017-04-01
In this paper, the stator/rotor currents control problem of doubly-fed induction generator under faulty line voltage is carried out. Common grid faults cause a steep decline in the line voltage profile, commonly denoted as voltage dip. This point is critical for such kind of machines, having their stator windings directly connected to the grid. In this respect, solid methodological nonlinear control theory arguments are exploited and applied to design a novel controller, whose main goal is to improve the system behaviour during voltage dips, endowing it with low voltage ride through capability, a fundamental feature required by modern Grid Codes. The proposed solution exploits both feedforward and feedback actions. The feedforward part relies on suitable reference trajectories for the system internal dynamics, which are designed to prevent large oscillations in the rotor currents and command voltages, excited by line perturbations. The feedback part uses state measurements and is designed according to Linear Matrix Inequalities (LMI) based saturated control techniques to further reduce oscillations, while explicitly accounting for the system constraints. Numerical simulations verify the benefits of the internal dynamics trajectory planning, and the saturated state feedback action, in crucially improving the Doubly-Fed Induction Machine response under severe grid faults.
Experimental Investigation of Hysteretic Dynamic Capillarity Effect in Unsaturated Flow
Zhuang, Luwen; Qin, Chao‐Zhong; de Waal, Arjen
2017-01-01
Abstract The difference between average pressures of two immiscible fluids is commonly assumed to be the same as macroscopic capillary pressure, which is considered to be a function of saturation only. However, under transient conditions, a dependence of this pressure difference on the time rate of saturation change has been observed by many researchers. This is commonly referred to as dynamic capillarity effect. As a first‐order approximation, the dynamic term is assumed to be linearly dependent on the time rate of change of saturation, through a material coefficient denoted by τ. In this study, a series of laboratory experiments were carried out to quantify the dynamic capillarity effect in an unsaturated sandy soil. Primary, main, and scanning drainage experiments, under both static and dynamic conditions, were performed on a sandy soil in a small cell. The value of the dynamic capillarity coefficient τ was calculated from the air‐water pressure differences and average saturation values during static and dynamic drainage experiments. We found a dependence of τ on saturation, which showed a similar trend for all drainage conditions. However, at any given saturation, the value of τ for primary drainage was larger than the value for main drainage and that was in turn larger than the value for scanning drainage. Each data set was fit a simple log‐linear equation, with different values of fitting parameters. This nonuniqueness of the relationship between τ and saturation and possible causes is discussed. PMID:29398729
Experimental Investigation of Hysteretic Dynamic Capillarity Effect in Unsaturated Flow
NASA Astrophysics Data System (ADS)
Zhuang, Luwen; Hassanizadeh, S. Majid; Qin, Chao-Zhong; de Waal, Arjen
2017-11-01
The difference between average pressures of two immiscible fluids is commonly assumed to be the same as macroscopic capillary pressure, which is considered to be a function of saturation only. However, under transient conditions, a dependence of this pressure difference on the time rate of saturation change has been observed by many researchers. This is commonly referred to as dynamic capillarity effect. As a first-order approximation, the dynamic term is assumed to be linearly dependent on the time rate of change of saturation, through a material coefficient denoted by τ. In this study, a series of laboratory experiments were carried out to quantify the dynamic capillarity effect in an unsaturated sandy soil. Primary, main, and scanning drainage experiments, under both static and dynamic conditions, were performed on a sandy soil in a small cell. The value of the dynamic capillarity coefficient τ was calculated from the air-water pressure differences and average saturation values during static and dynamic drainage experiments. We found a dependence of τ on saturation, which showed a similar trend for all drainage conditions. However, at any given saturation, the value of τ for primary drainage was larger than the value for main drainage and that was in turn larger than the value for scanning drainage. Each data set was fit a simple log-linear equation, with different values of fitting parameters. This nonuniqueness of the relationship between τ and saturation and possible causes is discussed.
[Stimulation parameters for automatic examination of color vision].
Sommerhalder, J; Pelizzone, M; Roth, A
1997-05-01
We have developed a polyvalent computer controlled instrument, which uses the "two equation method" (Rayleigh and Moreland equations) to measure human colour vision. This "colorimeter" (or anomaloscope) was used to determine the influence of some important stimulation parameters. The influence of stimulus exposure time, observation field size, absolute stimulus luminance, saturation and luminance mismatches between mixture and reference stimuli were measured on our computer controlled colorimeter. All subjects were normal observers. 1) An exposure time of 2s was found to be optimal for clinical work. 2) The Moreland equation on a 7 degrees observation field yields results in which population variability is comparable to a Rayleigh equation on a 2 degrees field. 3) A retinal illuminance between 40 and 1000 trolands can be used for automated Moreland matches. 4) The saturation of the reference field for the Moreland match can be preset to a fixed value. 5) It is important to vary automatically the radiance of the reference field to provide an approximate luminance match as the ratio of primaries in the mixture field is changed. These measurements allows us to determine optimal conditions for automated colour vision examinations and to make recommendations for an international standard.
Absolute frequencies of water lines near 790 nm with 10-11 accuracy
NASA Astrophysics Data System (ADS)
Chen, J.; Hua, T.-P.; Tao, L.-G.; Sun, Y. R.; Liu, A.-W.; Hu, S.-M.
2018-01-01
Water lines in the infrared are convenient frequency references. We present absolute positions of several H216O ro-vibrational transitions around 790 nm using comb-locked cavity ring-down saturation spectroscopy. Lamb dips of 6 water lines with saturation power in the range of 70-130 kW/cm2 were observed and the line positions were determined with an accuracy of 25 kHz, corresponding to a fractional uncertainty of 6.6 × 10-11. The present work demonstrates the capability to considerably improve the accuracy of the water line positions in the infrared.
NASA Astrophysics Data System (ADS)
Gade, John; Palmqvist, Dorte; Plomgård, Peter; Greisen, Gorm
2006-01-01
The purpose of the study was to compare algorithms of four methods (plus two modifications) for spectrophotometric haemoglobin saturation measurements. Comparison was made in tissue phantoms basically consisting of a phosphate buffer, Intralipid and blood, allowing samples to be taken for reference measurements. Three experimental series were made. In experiment A (eight phantoms) we used the Knoefel method and measured specific extinction coefficients with a reflection spectrophotometer. In experiment B (six phantoms) the fully oxygenated phantoms were gradually deoxygenated with baker's yeast, and simultaneous measurements were made with our spectrophotometer and with a reference oxymeter (ABL-605) in 3 min intervals. For each spectrophotometric measurement haemoglobin saturation was calculated with all algorithms and modifications, and compared with reference. In experiment C (11 phantoms) we evaluated the ability of a modification of the Knoefel method to measure haemoglobin concentration in absolute quantities using extinction coefficients from experiment A. Results. Experiment A: with the Knoefel method extinction coefficients (±SD) for oxyhaemoglobin at 553.04 and 573.75 nm were 1.117 (±0.0396) ODmM-1 and 1.680 (± 0.0815) ODmM-1, respectively, and for deoxyhaemoglobin 1.205 (± 0.0514) ODmM-1 and 0.953 (±0.0487) ODmM-1, respectively. Experiment B: high correlation with the reference was found in all methods (r = 0.94-0.97). However, agreement varied from evidently wrong in method 3 and the original method 4 (e.g. saturation above 160%) to high agreement in method 2 as well as the modifications of methods 1 and 4, where oxygen dissociation curves were close to the reference method. Experiment C: with the modified Knoefel method the mean haemoglobin concentration difference from reference was 8.3% and the correlation was high (r = 0.91). We conclude that method 2 and the modifications of 1 and 4 were superior to the others, but depended on known values in the same or similar phantoms. The original method 1 was independent of results from the tissue phantoms, but agreement was slightly poorer. Method 3 and the original method 4 could not be recommended. The ability of the modified method 1 to measure haemoglobin concentration is promising, but needs further development.
Molavi, Ali; Jalali, Aliakbar; Ghasemi Naraghi, Mahdi
2017-07-01
In this paper, based on the passivity theorem, an adaptive fuzzy controller is designed for a class of unknown nonaffine nonlinear systems with arbitrary relative degree and saturation input nonlinearity to track the desired trajectory. The system equations are in normal form and its unforced dynamic may be unstable. As relative degree one is a structural obstacle in system passivation approach, in this paper, backstepping method is used to circumvent this obstacle and passivate the system step by step. Because of the existence of uncertainty and disturbance in the system, exact passivation and reference tracking cannot be tackled, so the approximate passivation or passivation with respect to a set is obtained to hold the tracking error in a neighborhood around zero. Furthermore, in order to overcome the non-smoothness of the saturation input nonlinearity, a parametric smooth nonlinear function with arbitrary approximation error is used to approximate the input saturation. Finally, the simulation results for the theoretical and practical examples are given to validate the proposed controller. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Radis, M.; Iacomussi, P.; Aghemo, C.; Rossi, G.
2017-07-01
Interdependence between color and gloss is a concept well-known by artists, especially by old masters, but is not usually considered in material characterization. Indeed, measurement methods and definitions consider these two attributes individually. This research investigates how the available measurement methods for gloss and color (saturation) fit with corresponding perceptual qualities, glossiness and saturation. The definitions of both measured quantities, as well the measurement methodologies, were developed for reference materials (ceramic tiles for color and dark glass specimen for gloss) not representative of artwork materials and do not consider observation conditions similar with those adopted during exhibitions. The prediction of material appearance is recognized as one of the most important challenges in applied metrology, because appearance is the key to achieve effective exhibitions and consumers choices. The results of this study highlight that the two perceived qualities are mutually related, as well the measured quantities: gloss and saturation mutually interfere and the measurement methods and quantities are not uniform with the perceived qualities and the colorimetric coordinate C* no longer describes the perceived saturation.
Benni, Paul B; MacLeod, David; Ikeda, Keita; Lin, Hung-Mo
2018-04-01
We describe the validation methodology for the NIRS based FORE-SIGHT ELITE ® (CAS Medical Systems, Inc., Branford, CT, USA) tissue oximeter for cerebral and somatic tissue oxygen saturation (StO 2 ) measurements for adult subjects submitted to the United States Food and Drug Administration (FDA) to obtain clearance for clinical use. This validation methodology evolved from a history of NIRS validations in the literature and FDA recommended use of Deming regression and bootstrapping statistical validation methods. For cerebral validation, forehead cerebral StO 2 measurements were compared to a weighted 70:30 reference (REF CX B ) of co-oximeter internal jugular venous and arterial blood saturation of healthy adult subjects during a controlled hypoxia sequence, with a sensor placed on the forehead. For somatic validation, somatic StO 2 measurements were compared to a weighted 70:30 reference (REF CX S ) of co-oximetry central venous and arterial saturation values following a similar protocol, with sensors place on the flank, quadriceps muscle, and calf muscle. With informed consent, 25 subjects successfully completed the cerebral validation study. The bias and precision (1 SD) of cerebral StO 2 compared to REF CX B was -0.14 ± 3.07%. With informed consent, 24 subjects successfully completed the somatic validation study. The bias and precision of somatic StO 2 compared to REF CX S was 0.04 ± 4.22% from the average of flank, quadriceps, and calf StO 2 measurements to best represent the global whole body REF CX S . The NIRS validation methods presented potentially provide a reliable means to test NIRS monitors and qualify them for clinical use.
Wang, Xiao-Hui; Peng, Hong-Shang; Cheng, Kun; Liu, Xiao-Ming; Liu, Yuan-An; Yang, Wei
2018-04-27
Ratiometric fluorescent nanoparticles (NPs) under two-photon excitation are successfully developed for sensing dissolved oxygen. The NPs comprise the oxygen probe Pt(II)-porphyrins (PtTFPP) and fluorescent organic semiconducting polymer (PFO). PFO polymer acts as both a two-photon antenna and a reference dye, while PtTFPP absorbs the photonic energy transferred by the PFO under two-photon excitation at 740 nm to sense oxygen. The red fluorescence of PtTFPP is sensitive to oxygen with a quenching response of 88% from nitrogen saturation to oxygen saturation, and PFO gives oxygen-insensitive referenced blue fluorescence. The fluorescence quenching of the NPs against oxygen at two-photon excitation follows a linear Stern-Volmer behavior. The nanosensors exhibit low cytotoxic effects as well as effortless cellular uptake. When incorporated into cells, the ratio of the signals increases up to about 500% from oxygen-saturated to oxygen-free environment.
Aaland, K.
1983-08-09
A switching system for delivering pulses of power from a source to a load using a storage capacitor charged through a rectifier, and maintained charged to a reference voltage level by a transistor switch and voltage comparator. A thyristor is triggered to discharge the storage capacitor through a saturable reactor and fractional turn saturable transformer having a secondary to primary turn ratio N of n:l/n = n[sup 2]. The saturable reactor functions as a soaker'' while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor charges, and then switches to a low impedance state to dump the charge of the storage capacitor into the load through the coupling capacitor. The transformer is comprised of a multilayer core having two secondary windings tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe for a linear particle accelerator and capacitance of a pulse forming network. To hold off discharge of the capacitance until it is fully charged, a saturable core is provided around the resistive beampipe to isolate the beampipe from the capacitance until it is fully charged. 5 figs.
The Digital Sublime: Lessons from Kelli Connell's "Double Life"
ERIC Educational Resources Information Center
Huang, Yi-hui
2012-01-01
The digital sublime refers to digital-composite photography that presents "the existence of something unpresentable" and that renders a matchless look a sophisticated fabrication, a perfect and clean composition, a maximum color saturation, a multiple-point perspective, and stunning or newfangled content. Abandoning the traditional one-shot mode…
ERIC Educational Resources Information Center
Moinester, Murray; Gerland, Lars; Liger-Belair, Gerard; Ocherashvili, Aharon
2012-01-01
We describe the fluid dynamics principles governing the up-down oscillatory cycling of a bubble-covered, low-density, low-mass ball of material (referred to henceforth as a "fizz-ball") immersed inside a glass of bubbling (super-saturated) carbonated liquid. The bubbles serve to desaturate the liquid of excess CO[subscript 2]. The fizz-ball acts…
Development and validation of a cerebral oximeter capable of absolute accuracy.
MacLeod, David B; Ikeda, Keita; Vacchiano, Charles; Lobbestael, Aaron; Wahr, Joyce A; Shaw, Andrew D
2012-12-01
Cerebral oximetry may be a valuable monitor, but few validation data are available, and most report the change from baseline rather than absolute accuracy, which may be affected by individuals whose oximetric values are outside the expected range. The authors sought to develop and validate a cerebral oximeter capable of absolute accuracy. An in vivo research study. A university human physiology laboratory. Healthy human volunteers were enrolled in calibration and validation studies of 2 cerebral oximetric sensors, the Nonin 8000CA and 8004CA. The 8000CA validation study identified 5 individuals with atypical cerebral oxygenation values; their data were used to design the 8004CA sensor, which subsequently underwent calibration and validation. Volunteers were taken through a stepwise hypoxia protocol to a minimum saturation of peripheral oxygen. Arteriovenous saturation (70% jugular bulb venous saturation and 30% arterial saturation) at 6 hypoxic plateaus was used as the reference value for the cerebral oximeter. Absolute accuracy was defined using a combination of the bias and precision of the paired saturations (A(RMS)). In the validation study for the 8000CA sensor (n = 9, 106 plateaus), relative accuracy was an A(RMS) of 2.7, with an absolute accuracy of 8.1, meeting the criteria for a relative (trend) monitor, but not an absolute monitor. In the validation study for the 8004CA sensor (n = 11, 119 plateaus), the A(RMS) of the 8004CA was 4.1, meeting the prespecified success criterion of <5.0. The Nonin cerebral oximeter using the 8004CA sensor can provide absolute data on regional cerebral saturation compared with arteriovenous saturation, even in subjects previously shown to have values outside the normal population distribution curves. Copyright © 2012 Elsevier Inc. All rights reserved.
Electrolyte for EC-V profiling of InP and GaAs based structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faur, M.; Faur, M.; Goradia, M.
Electrochemical C-V (EC-V) profiling is the most often used and convenient method for accurate majority carrier concentration depth profiling of semiconductors. Although, according to the authors, FAP is the best electrolyte for accurate profiling of InP structures, it does not work well with other III-V compounds. To overcome this, recently, the authors have developed a new electrolyte, which they call UNIEL (UNIversal ELectrolyte), which works well with all the materials. However, as with the FAP electrolyte, the presence of HF makes the UNIEL incompatible with the electrochemical cell of Polaron EC-V profilers manufactured by BIO-RAD. By slightly modifying the electrochemicalmore » cell configuration the authors are able to use both the FAP and UNIEL electrolytes, without destroying the calomel electrode. Recently, they have, nevertheless, experimented with variations of the UNIEL with no HF content for EC-V profiling of structures based on InP and GaAs. Presently available results are presented here.« less
Sarhadi, Pouria; Noei, Abolfazl Ranjbar; Khosravi, Alireza
2016-11-01
Input saturations and uncertain dynamics are among the practical challenges in control of autonomous vehicles. Adaptive control is known as a proper method to deal with the uncertain dynamics of these systems. Therefore, incorporating the ability to confront with input saturation in adaptive controllers can be valuable. In this paper, an adaptive autopilot is presented for the pitch and yaw channels of an autonomous underwater vehicle (AUV) in the presence of input saturations. This will be performed by combination of a model reference adaptive control (MRAC) with integral state feedback with a modern anti-windup (AW) compensator. MRAC with integral state feedback is commonly used in autonomous vehicles. However, some proper modifications need to be taken into account in order to cope with the saturation problem. To this end, a Riccati-based anti-windup (AW) compensator is employed. The presented technique is applied to the non-linear six degrees of freedom (DOF) model of an AUV and the obtained results are compared with that of its baseline method. Several simulation scenarios are executed in the pitch and yaw channels to evaluate the controller performance. Moreover, effectiveness of proposed adaptive controller is comprehensively investigated by implementing Monte Carlo simulations. The obtained results verify the performance of proposed method. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
The Intrinsic Variability in the Water Vapor Saturation Ratio Due to Turbulence
NASA Astrophysics Data System (ADS)
Anderson, Jesse Charles
The water vapor concentration plays an important role for many atmospheric processes. The mean concentration is key to understand water vapor's effect on the climate as a greenhouse gas. The fluctuations about the mean are important to understand heat fluxes between Earth's surface and the boundary layer. These fluctuations are linked to turbulence that is present in the boundary layer. Turbulent conditions are simulated in Michigan Tech's multiphase, turbulent reaction chamber, the pi chamber. Measurements for temperature and water vapor concentration were recorded under forced Rayleigh- Benard convection at several turbulent intensities. These were used to calculate the saturation ratio, often referred to as the relative humidity. The fluctuations in the water vapor concentration were found to be the more important than the temperature for the variability of the saturation ratio. The fluctuations in the saturation ratio result in some cloud droplets experiencing a higher supersaturation than other cloud droplets, causing those "lucky" droplets to grow at a faster rate than other droplets. This difference in growth rates could contribute to a broadening of the size distribution of cloud droplets, resulting in the enhancement of collision-coalescence. These fluctuations become more pronounced with more intense turbulence.
NASA Astrophysics Data System (ADS)
Wang, Xiao; Feng, Jiafeng; Guo, Peng; Wei, H. X.; Han, X. F.; Fang, B.; Zeng, Z. M.
2017-12-01
We report the temperature dependence of the spin-torque (ST) driven ferromagnetic resonance in MgO-based magnetic tunnel junction (MTJ) nanopillars with a perpendicularly free layer and an in-plane reference layer. From the evolution of the resonance frequency with magnetic field, we clearly identify the free-layer resonance mode and reference-layer mode. For the reference layer, we demonstrate a monotonic increase in resonance frequency and the effective damping with decreasing temperature, which suggests the saturated magnetization of the reference layer is dominant. However, for the free layer, the frequency and damping exhibit almost no change with temperature, indicating that the perpendicular magnetic anisotropy plays an important role in magnetization dynamics of the free layer.
Riss, Patrick J; Hong, Young T; Williamson, David; Caprioli, Daniele; Sitnikov, Sergey; Ferrari, Valentina; Sawiak, Steve J; Baron, Jean-Claude; Dalley, Jeffrey W; Fryer, Tim D; Aigbirhio, Franklin I
2011-01-01
The 5-hydroxytryptamine type 2a (5-HT2A) selective radiotracer [18F]altanserin has been subjected to a quantitative micro-positron emission tomography study in Lister Hooded rats. Metabolite-corrected plasma input modeling was compared with reference tissue modeling using the cerebellum as reference tissue. [18F]altanserin showed sufficient brain uptake in a distribution pattern consistent with the known distribution of 5-HT2A receptors. Full binding saturation and displacement was documented, and no significant uptake of radioactive metabolites was detected in the brain. Blood input as well as reference tissue models were equally appropriate to describe the radiotracer kinetics. [18F]altanserin is suitable for quantification of 5-HT2A receptor availability in rats. PMID:21750562
NASA Astrophysics Data System (ADS)
Mihalache, Constance
Assessing the potential for instability in non-saturated geomaterials is of critical importance for the prevention of disastrous failures that occur through these materials, from natural hazards such as rainfall-induced flow slides, to underwater sediment collapse due to methane hydrate dissociation, to the failure of key infrastructure components. In particular, the gaseous and liquid phases present within the pores of a geomaterial play a vital role in its overall behavior, and consequently must be considered in stability analyses. In this work, analytical techniques are presented to evaluate material stability for the different saturation states that occur during a wetting process, where soils progress from unsaturated conditions in the funicular regime, to quasi-saturated conditions in the insular regime, to complete saturation. Each of these different saturation states involves different interactions between the pore fluids and the solid skeleton hosting them. For example, while unsaturated soil behavior is characterized by the capillary effects from the interface between the gaseous and liquid phases, the dominant effect of isolated bubbles within the quasi-saturated regime is to increase the compressibility of the interstitial fluid mixture. By considering the different characteristics of these saturation states, energy-based work input expressions are developed and then used to derive criteria for loss of controllability of the material response. These criteria are then used to assess the stability of geomaterials under various loading configurations. Then, to unite the funicular and insular saturation regimes, the same methodology is adapted to the derivation of comprehensive three-phase criteria for non-saturated soils. An alternative interpretation of such constitutive singularities is also derived, with reference to the ill-posedness of the mass balance equations that control the transient flow of the fluid constituents of a deformable multiphase porous medium. Lastly, the concepts considered throughout the study are applied to the solution of boundary-value problems, using a finite element approach. Overall, it is shown that depending on the considered saturation regime, different stability criteria need to be applied for the accurate interpretation of material behavior. These techniques provide a mechanistic interpretation for a range of processes, such as the nature of so-called "wetting-collapse" events, the variability of the instability line for flow failures acting through gassy sediments, and the onset of runaway failures at the transition between funicular and insular states.
Aaland, Kristian
1983-01-01
A switching system for delivering pulses of power from a source (10) to a load (20) using a storage capacitor (C3) charged through a rectifier (D1, D2), and maintained charged to a reference voltage level by a transistor switch (Q1) and voltage comparator (12). A thyristor (22) is triggered to discharge the storage capacitor through a saturable reactor (18) and fractional turn saturable transformer (16) having a secondary to primary turn ratio N of n:l/n=n.sup.2. The saturable reactor (18) functions as a "soaker" while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor (C4) charges, and then switches to a low impedance state to dump the charge of the storage capacitor (C3) into the load through the coupling capacitor (C4). The transformer is comprised of a multilayer core (26) having two secondary windings (28, 30) tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes (32, 34) for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe (40) for a linear particle accelerator and capacitance of a pulse forming network (42). To hold off discharge of the capacitance until it is fully charged, a saturable core (44) is provided around the resistive beampipe (40) to isolate the beampipe from the capacitance (42) until it is fully charged.
Bailey, Ryan T.; Morway, Eric D.; Niswonger, Richard G.; Gates, Timothy K.
2013-01-01
A numerical model was developed that is capable of simulating multispecies reactive solute transport in variably saturated porous media. This model consists of a modified version of the reactive transport model RT3D (Reactive Transport in 3 Dimensions) that is linked to the Unsaturated-Zone Flow (UZF1) package and MODFLOW. Referred to as UZF-RT3D, the model is tested against published analytical benchmarks as well as other published contaminant transport models, including HYDRUS-1D, VS2DT, and SUTRA, and the coupled flow and transport modeling system of CATHY and TRAN3D. Comparisons in one-dimensional, two-dimensional, and three-dimensional variably saturated systems are explored. While several test cases are included to verify the correct implementation of variably saturated transport in UZF-RT3D, other cases are included to demonstrate the usefulness of the code in terms of model run-time and handling the reaction kinetics of multiple interacting species in variably saturated subsurface systems. As UZF1 relies on a kinematic-wave approximation for unsaturated flow that neglects the diffusive terms in Richards equation, UZF-RT3D can be used for large-scale aquifer systems for which the UZF1 formulation is reasonable, that is, capillary-pressure gradients can be neglected and soil parameters can be treated as homogeneous. Decreased model run-time and the ability to include site-specific chemical species and chemical reactions make UZF-RT3D an attractive model for efficient simulation of multispecies reactive transport in variably saturated large-scale subsurface systems.
Hirche, T O; Born, T; Jungblut, S; Sczepanski, B; Kenn, K; Köhnlein, T; Hirche, H; Wagner, T O
2008-10-27
Oxy-Gen lite, a recently developed combined electrolysis and fuel cell technology, de-novo generates oxygen with high purity for medical use from distilled water and room air. However, its use in patients with chronic respiratory failure has never been evaluated. To test the clinical applicability and safety of Oxy-Gen lite technology, we enrolled 32 COPD patients with chronic hypoxemia and long-term oxygen therapy (LTOT) in a controlled, randomized, multicenter clinical trial. Standard continuous oxygen therapy with a maximal flow rate of 2 L/min was tested against pulsatile oxygen delivery by Oxy-Gen lite. Oxygen saturation at seated-rest was recorded over 30 min and used as a primary read-out parameter. Oxygen saturation was also recorded during mild physical strain (speaking out loud) or overnight's sleep. Both methods of oxygen supply established oxygen saturations within the normal range (i.e., upper plateau of the sigmoid oxyhaemoglobin dissociation curve) compared to breathing room air (p<0.0001). Mean oxygen saturation under standard continuous oxygen flow or Oxy-Gen lite technology during rest, physical strain or sleep proved statistically equivalent (95%CI<2.5% of reference saturation). The use of Oxy-Gen lite in COPD patients with hypoxemia and LTOT
The effect of a microscale fracture on dynamic capillary pressure of two-phase flow in porous media
NASA Astrophysics Data System (ADS)
Tang, Mingming; Lu, Shuangfang; Zhan, Hongbin; Wenqjie, Guo; Ma, Huifang
2018-03-01
Dynamic capillary pressure (DCP) effects, which is vital for predicting multiphase flow behavior in porous media, refers to the injection rate dependence capillary pressure observed during non-equilibrium displacement experiments. However, a clear picture of the effects of microscale fractures on DCP remains elusive. This study quantified the effects of microscale fractures on DCP and simulated pore-scale force and saturation change in fractured porous media using the multiphase lattice Boltzmann method (LBM). Eighteen simulation cases were carried out to calculate DCP as a function of wetting phase saturation. The effects of viscosity ratio and fracture orientation, aperture and length on DCP and DCP coefficient τ were investigated, where τ refers to the ratio of the difference of DCP and static capillary pressure (SCP) over the rate of wetting-phase saturation change versus time. Significant differences in τ values were observed between unfractured and fractured porous media. The τ values of fractured porous media were 1.1 × 104 Pa ms to 5.68 × 105 Pa ms, which were one or two orders of magnitude lower than those of unfractured porous media with a value of 4 × 106 Pa. ms. A horizontal fracture had greater effects on DCP and τ than a vertical fracture, given the same fracture aperture and length. This study suggested that a microscale fracture might result in large magnitude changes in DCP for two-phase flow.
Sikora, Karol; Neubauer, Damian; Jaśkiewicz, Maciej; Kamysz, Wojciech
2018-01-01
In view of the increasing interest in peptides in various market sectors, a stronger emphasis on topics related to their production has been seen. Fmoc-based solid phase peptide synthesis, although being fast and efficient, provides final products with significant amounts of trifluoroacetate ions in the form of either a counter-ion or an unbound impurity. Because of the proven toxicity towards cells and peptide activity inhibition, ion exchange to more biocompatible one is purposeful. Additionally, as most of the currently used counter-ion exchange techniques are time-consuming and burdened by peptide yield reduction risk, development of a new approach is still a sensible solution. In this study, we examined the potential of peptide counter-ion exchange using non-aqueous organic solvents saturated with HCl. Counter-ion exchange of a model peptide, citropin 1.1 (GLFDVIKKVASVIGGL-NH 2 ), for each solvent was conducted through incubation with subsequent evaporation under reduced pressure, dissolution in water and lyophilization. Each exchange was performed four times and compared to a reference method-lyophilization of the peptide from an 0.1 M HCl solution. The results showed superior counter-ion exchange efficiency for most of the organic solutions in relation to the reference method. Moreover, HCl-saturated acetonitrile and tert -butanol provided a satisfying exchange level after just one repetition. Thus, those two organic solvents can be potentially introduced into routine peptide counter-ion exchange.
Regulated dc-to-dc converter for voltage step-up or step-down with input-output isolation
NASA Technical Reports Server (NTRS)
Feng, S. Y.; Wilson, T. G. (Inventor)
1973-01-01
A closed loop regulated dc-to-dc converter employing an unregulated two winding inductive energy storage converter is provided by using a magnetically coupled multivibrator acting as duty cycle generator to drive the converter. The multivibrator is comprised of two transistor switches and a saturable transformer. The output of the converter is compared with a reference in a comparator which transmits a binary zero until the output exceeds the reference. When the output exceeds the reference, the binary output of the comparator drives transistor switches to turn the multivibrator off. The multivibrator is unbalanced so that a predetermined transistor will always turn on first when the binary feedback signal becomes zero.
NASA Astrophysics Data System (ADS)
Kim, Ji-hyun; Han, Jae-Ho; Jeong, Jichai
2015-09-01
Integration time and reference intensity are important factors for achieving high signal-to-noise ratio (SNR) and sensitivity in optical coherence tomography (OCT). In this context, we present an adaptive optimization method of reference intensity for OCT setup. The reference intensity is automatically controlled by tilting a beam position using a Galvanometric scanning mirror system. Before sample scanning, the OCT system acquires two dimensional intensity map with normalized intensity and variables in color spaces using false-color mapping. Then, the system increases or decreases reference intensity following the map data for optimization with a given algorithm. In our experiments, the proposed method successfully corrected the reference intensity with maintaining spectral shape, enabled to change integration time without manual calibration of the reference intensity, and prevented image degradation due to over-saturation and insufficient reference intensity. Also, SNR and sensitivity could be improved by increasing integration time with automatic adjustment of the reference intensity. We believe that our findings can significantly aid in the optimization of SNR and sensitivity for optical coherence tomography systems.
21 CFR 801.420 - Hearing aid devices; professional and patient labeling.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... (ii) History of active drainage from the ear within the previous 90 days. (iii) History of sudden or...). (ii) Frequency response curve. (iii) Average saturation output (HF-Average SSPL 90). (iv) Average full-on gain (HF-Average full-on gain). (v) Reference test gain. (vi) Frequency range. (vii) Total...
21 CFR 801.420 - Hearing aid devices; professional and patient labeling.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... (ii) History of active drainage from the ear within the previous 90 days. (iii) History of sudden or...). (ii) Frequency response curve. (iii) Average saturation output (HF-Average SSPL 90). (iv) Average full-on gain (HF-Average full-on gain). (v) Reference test gain. (vi) Frequency range. (vii) Total...
Streit, F; Delettre, J; Corrieu, G; Béal, C
2008-10-01
This work aimed at clarifying the physiological responses of Lactobacillus delbrueckii subsp. bulgaricus CFL1 cells after exposure to acidification at the end of fermentation, in relation to their cryotolerance. Cells acidified at the end of the fermentation (pH 5.25 for 30 min) had their cryotolerance improved as compared to the reference condition (pH 6.0). By analyzing the cytosolic proteome, it was established that changes occurred in the synthesis of 21 proteins, involved in energy metabolism, nucleotide and protein synthesis and stress response. Acidification also induced a slight decrease in unsaturated to saturated and cyclic to saturated membrane fatty acid ratios. Lactobacillus bulgaricus CFL1 was able to develop a combined physiological response at both membrane and cytosolic levels. This acid adaptation was referred as a cross-protection phenomenon as it allowed the cells to become more tolerant to cold stress. This study increased knowledge concerning the physiological mechanisms that explained the cross-protection by acid adaptation. It may be useful for improving cryotolerance of lactic acid bacteria, either in cells banks or in an industrial context.
Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Jia; Sun, Guohua; Li, Hongmei
2012-10-15
Certified reference materials (CRMs) of water content are widely used in the calibration and validation of Karl Fischer coulometry and volumetry. In this study, the water content of the water saturated 1-octanol (WSO) CRM was certified by Karl Fischer coulometry, volumetry and quantitative nuclear magnetic resonance (Q NMR). The water content recovery by coulometry was 99.76% with a diaphragm-less electrode and Coulomat AG anolyte. The relative bias between the coulometry and volumetry results was 0.06%. In Q NMR, the water content of WSO is traceable to the International System (SI) of units through the purity of internal standard. The relative bias of water content in WSO between Q NMR and volumetry was 0.50%. The consistency of results for these three independent methods improves the accuracy of the certification of the RM. The certified water content of the WSO CRM was 4.76% with an expanded uncertainty of 0.09%. Copyright © 2012 Elsevier Ltd. All rights reserved.
Improvement of Biocatalysts for Industrial and Environmental Purposes by Saturation Mutagenesis
Valetti, Francesca; Gilardi, Gianfranco
2013-01-01
Laboratory evolution techniques are becoming increasingly widespread among protein engineers for the development of novel and designed biocatalysts. The palette of different approaches ranges from complete randomized strategies to rational and structure-guided mutagenesis, with a wide variety of costs, impacts, drawbacks and relevance to biotechnology. A technique that convincingly compromises the extremes of fully randomized vs. rational mutagenesis, with a high benefit/cost ratio, is saturation mutagenesis. Here we will present and discuss this approach in its many facets, also tackling the issue of randomization, statistical evaluation of library completeness and throughput efficiency of screening methods. Successful recent applications covering different classes of enzymes will be presented referring to the literature and to research lines pursued in our group. The focus is put on saturation mutagenesis as a tool for designing novel biocatalysts specifically relevant to production of fine chemicals for improving bulk enzymes for industry and engineering technical enzymes involved in treatment of waste, detoxification and production of clean energy from renewable sources. PMID:24970191
NASA Astrophysics Data System (ADS)
Myers, M.; Stalker, L.; LaForce, T.; Pejcic, B.; Dyt, C.; Ho, K.; Ennis-King, J.
2013-12-01
Residual trapping, that is CO2 held in the rock pore space due to capillarity, is an important storage mechanism in geo-sequestration of over the short to medium term (up to 1000 years). As such residual CO2 saturation is a critical reservoir parameter for assessing the storage capacity and security of carbon capture and storage (CCS). As a component of the CO2CRC's Residual Gas Saturation and Dissolution Test at the CO2CRC Otway Project site in Victoria (Australia), we have recently tested a suite of reactive esters (triacetin, tripropionin and propylene glycol diacetate) in a single well chemical tracer test to determine residual CO2 saturation. The goal of this project was to assess and validate a suite of possible tests that could be implemented to determine residual CO2 saturation. For this test, the chemical tracers were injected with a saturated CO2/water mixture into the formation (that is already at residual CO2 saturation) where they were allowed to 'soak' for approximately 10 days allowing for the partial hydrolysis of the esters to their corresponding carboxylic acids and alcohols. Water containing the tracers was then produced from the well resulting in over 600 tracer samples over a period of 12 hours. A selection of these samples were analysed for tracer content and to establish tracer breakthrough curves. To understand the behaviour of these chemical tracers in the downhole environment containing residually trapped supercritical CO2 and formation water, it is necessary to determine the supercritical CO2/water partition coefficients. We have previously determined these in the laboratory (Myers et al., 2012) and they are used here to model the tracer behaviour and provide an estimate of the residual CO2 saturation. Two different computational simulators were used to analyse the tracer breakthrough profiles. The first is based on simple chromatographic retardation and has been used extensively in single well chemical tracer tests to determine residual oil saturation and the second is based on TOUGH2. The estimates of residual saturation given by these models were similar giving a very low residual CO2 saturation value. We suspect that this low value might be due to CO2 being inadvertently dissolved in the near wellbore region prior to this test. This possible dissolution of CO2 may be attributed to the complexity of the multi-test sequence (including other tracer tests prior to this particular test) used in the overall program at of the Residual Gas Saturation and Dissolution Test. References Myers, M., Stalker, L., Ross, A., Dyt, C., Ho, K.-B., 2012. Method for the determination of residual carbon dioxide saturation using reactive ester tracers. Applied Geochemistry 27, 2148-2156.
Saturation of the turbulent dynamo.
Schober, J; Schleicher, D R G; Federrath, C; Bovino, S; Klessen, R S
2015-08-01
The origin of strong magnetic fields in the Universe can be explained by amplifying weak seed fields via turbulent motions on small spatial scales and subsequently transporting the magnetic energy to larger scales. This process is known as the turbulent dynamo and depends on the properties of turbulence, i.e., on the hydrodynamical Reynolds number and the compressibility of the gas, and on the magnetic diffusivity. While we know the growth rate of the magnetic energy in the linear regime, the saturation level, i.e., the ratio of magnetic energy to turbulent kinetic energy that can be reached, is not known from analytical calculations. In this paper we present a scale-dependent saturation model based on an effective turbulent resistivity which is determined by the turnover time scale of turbulent eddies and the magnetic energy density. The magnetic resistivity increases compared to the Spitzer value and the effective scale on which the magnetic energy spectrum is at its maximum moves to larger spatial scales. This process ends when the peak reaches a characteristic wave number k☆ which is determined by the critical magnetic Reynolds number. The saturation level of the dynamo also depends on the type of turbulence and differs for the limits of large and small magnetic Prandtl numbers Pm. With our model we find saturation levels between 43.8% and 1.3% for Pm≫1 and between 2.43% and 0.135% for Pm≪1, where the higher values refer to incompressible turbulence and the lower ones to highly compressible turbulence.
Vantage point - Early warning flaws.
Swinden, Donna
2014-08-28
USING AN EARLY warning score (EWS) system should improve the detection of acutely deteriorating patients. Under such a system, a score is allocated to each of six physiological measurements including respiratory rate and oxygen saturations, which are aggregated to produce an overall score. An aggregated score of seven or higher prompts nursing staff to refer a patient for emergency assessment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of coronary heart disease. (1) Cardiovascular disease means diseases of the heart and circulatory system. Coronary heart disease is the most common and serious form of cardiovascular disease and refers... cholesterol and risk of coronary heart disease. 101.75 Section 101.75 Food and Drugs FOOD AND DRUG...
ERIC Educational Resources Information Center
Reynolds, Matthew R.; Keith, Timothy Z.
2007-01-01
Spearman's "law of diminishing returns" or SLODR refers to a decrease in "g" saturation as ability level increases. SLODR has been demonstrated in a number of intellectual batteries but several important aspects of the phenomenon are not yet well understood. We investigated the presence of SLODR in the Kaufman Assessment…
NASA Astrophysics Data System (ADS)
Ghanbarian, Behzad; Sahimi, Muhammad; Daigle, Hugh
2016-07-01
Accurate prediction of the relative permeability to water under partially saturated condition has broad applications and has been studied intensively since the 1940s by petroleum, chemical, and civil engineers, as well as hydrologists and soil scientists. Many models have been developed for this purpose, ranging from those that represent the pore space as a bundle of capillary tubes, to those that utilize complex networks of interconnected pore bodies and pore throats with various cross-section shapes. In this paper, we propose an approach based on the effective-medium approximation (EMA) and percolation theory in order to predict the water relative permeability. The approach is general and applicable to any type of porous media. We use the method to compute the water relative permeability in porous media whose pore-size distribution follows a power law. The EMA is invoked to predict the relative permeability from the fully saturated pore space to some intermediate water saturation that represents a crossover from the EMA to what we refer to as the "critical region." In the critical region below the crossover water saturation Swx, but still above the critical water saturation Swc (the residual saturation or the percolation threshold of the water phase), the universal power law predicted by percolation theory is used to compute the relative permeability. To evaluate the accuracy of the approach, data for 21 sets of undisturbed laboratory samples were selected from the UNSODA database. For 14 cases, the predicted relative permeabilities are in good agreement with the data. For the remaining seven samples, however, the theory underestimates the relative permeabilities. Some plausible sources of the discrepancy are discussed.
Discussion of pore pressure transmission under rain infiltration in a soil layer
NASA Astrophysics Data System (ADS)
Yang, S. Y.; Jan, C. D.
2017-12-01
The vadose zone (or unsaturated zone) denotes the geologic media between ground surface and the water table in situ where the openings, or pores, in the soil (rock) layers are partially filled with water and air. In this landscape, rainwater infiltrates into soils advancing through this vadose zone and could generates a shallow saturation zone at soil bedrock boundary due to permeability contrast. This saturation zone leads to downslope shallow subsurface storm runoff that contributes to a part of saturation overland flow, dominating water reaching river channels. Hence, unsaturated processes (e.g., rain infiltration) is an important issue that can determine the timing and magnitude of positive pore pressure and discharge peaks, and the characteristics of runoff, water chemistry, hillslope stability is also tie to the processes. In this study, we investigated the transmission of pore pressure evolution in the vadose zone for diverse soil materials based on poroelasticity theory. Commonly, a traditional way is to utilize the Richard's equation to predict pore pressure evolution under unsaturated rain infiltration, ignoring the inertial effect on the process. Here we relax this limitation and propose two reference time tk and tep that can represent the arriving time at a certain depth of wave propagation and dissipation, respectively. Form ground surface to a depth of 1 m, tk has significant differences under nearly unsaturated conditions for diverse soil properties; however, no evident variations in tk can be observed under nearly saturated conditions. Values of tep for loose, cohesionless soils are much greater but decreases to the smallest one (within 1 day) than those for other soil properties under a nearly saturated condition. Results indicate that transient pore pressure transmission is mainly dominated by dynamic wave propagation but the effect of dissipation could become more important with increase in water saturation.
Communication: Saturated CO2 absorption near 1.6 μm for kilohertz-accuracy transition frequencies
NASA Astrophysics Data System (ADS)
Burkart, Johannes; Sala, Tommaso; Romanini, Daniele; Marangoni, Marco; Campargue, Alain; Kassi, Samir
2015-05-01
Doppler-free saturated-absorption Lamb dips were measured on weak rovibrational lines of 12C16O2 between 6189 and 6215 cm-1 at sub-Pa pressures using optical feedback frequency stabilized cavity ring-down spectroscopy. By referencing the laser source to an optical frequency comb, transition frequencies for ten lines of the 30013←00001 band P-branch and two lines of the 31113←01101 hot band R-branch were determined with an accuracy of a few parts in 1011. Involving rotational quantum numbers up to 42, the data were used for improving the upper level spectroscopic constants. These results provide a highly accurate reference frequency grid over the spectral interval from 1599 to 1616 nm.
Goo, Soyeon; Han, June-Chiew; Nisbet, Linley A; Legrice, Ian J; Taberner, Andrew J; Loiselle, Denis S
2014-01-01
Abstract It is generally recognized that increased consumption of polyunsaturated fatty acids, fish oil (FO) in particular, is beneficial to cardiac and cardiovascular health, whereas equivalent consumption of saturated fats is deleterious. In this study, we explore this divergence, adopting a limited purview: The effect of dietary fatty acids on the mechanoenergetics of the isolated heart per se. Mechanical indices of interest include left-ventricular (LV) developed pressure, stroke work, cardiac output, coronary perfusion, and LV power. The principal energetic index is whole-heart oxygen consumption, which we subdivide into its active and basal moieties. The primary mechanoenergetic index of interest is cardiac efficiency, the ratio of work performance to metabolic energy expenditure. Wistar rats were divided into three Diet groups and fed, ad libitum, reference (REF), fish oil-supplemented (FO), or saturated fatty acid-supplemented (SFA) food for 6 weeks. At the end of the dietary period, hearts were excised, mounted in a working-heart rig, and their mechanoenergetic performance quantified over a range of preloads and afterloads. Analyses of Variance revealed no difference in any of the individual mechanoenergetic indices among the three Diet groups. In particular, we found no effect of prior dietary supplementation with either saturated or unsaturated fatty acids on the global efficiency of the heart.
Fine resolution map of top- and subsoil carbon sequestration potential in France.
Chen, Songchao; Martin, Manuel P; Saby, Nicolas P A; Walter, Christian; Angers, Denis A; Arrouays, Dominique
2018-07-15
Although soils have a high potential to offset CO 2 emissions through its conversion into soil organic carbon (SOC) with long turnover time, it is widely accepted that there is an upper limit of soil stable C storage, which is referred to SOC saturation. In this study we estimate SOC saturation in French topsoil (0-30cm) and subsoil (30-50cm), using the Hassink equation and calculate the additional SOC sequestration potential (SOC sp ) by the difference between SOC saturation and fine fraction C on an unbiased sampling set of sites covering whole mainland France. We then map with fine resolution the geographical distribution of SOC sp over the French territory using a regression Kriging approach with environmental covariates. Results show that the controlling factors of SOC sp differ from topsoil and subsoil. The main controlling factor of SOCsp in topsoils is land use. Nearly half of forest topsoils are over-saturated with a SOC sp close to 0 (mean and standard error at 0.19±0.12) whereas cropland, vineyard and orchard soils are largely unsaturated with degrees of C saturation deficit at 36.45±0.68% and 57.10±1.64%, respectively. The determinant of C sequestration potential in subsoils is related to parent material. There is a large additional SOC sp in subsoil for all land uses with degrees of C saturation deficit between 48.52±4.83% and 68.68±0.42%. Overall the SOCsp for French soils appears to be very large (1008Mt C for topsoil and 1360Mt C for subsoil) when compared to previous total SOC stocks estimates of about 3.5Gt in French topsoil. Our results also show that overall, 176Mt C exceed C saturation in French topsoil and might thus be very sensitive to land use change. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Front-of-pack symbols are not a reliable indicator of products with healthier nutrient profiles.
Emrich, Teri E; Qi, Ying; Cohen, Joanna E; Lou, Wendy Y; L'Abbe, Mary L
2015-01-01
Front-of-pack (FOP) nutrition rating systems and symbols are a form of nutrition marketing used on food labels worldwide. In the absence of standardized criteria for their use, it is unclear if FOP symbols are being used to promote products more nutritious than products without symbols. To compare the amount of calories, saturated fat, sodium, and sugar in products with FOP symbols, and different FOP symbol types, to products without symbols. The median calorie, saturated fat, sodium, and sugar content per reference amount of products with FOP symbols were compared to products without FOP symbols using data from the Food Label Information Program, a database of 10,487 Canadian packaged food labels. Ten food categories and 60 subcategories were analyzed. Nutrient content differences were compared using Wilcoxon rank-sum test; differences greater than 25% were deemed nutritionally relevant. Products with FOP symbols were not uniformly lower in calories, saturated fat, sodium, and sugar per reference amount than products without these symbols in any food category and the majority of subcategories (59/60). None of the different FOP types examined were used to market products with overall better nutritional profiles than products without this type of marketing. FOP symbols are being used to market foods that are no more nutritious than foods without this type of marketing. Because FOP symbols may influence consumer perceptions of products and their purchases, it may be a useful public health strategy to set minimum nutritional standards for products using FOP symbol marketing. Copyright © 2014 Elsevier Ltd. All rights reserved.
Colorimetric device for measurement of transvascular fluid flux in blood-perfused organs.
Oppenheimer, L; Richardson, W N; Bilan, D; Hoppensack, M
1987-01-01
The aim of this study was to develop a device capable of measuring transvascular fluid flux in blood-perfused organs. For any given blood flow through the organ (QT), transvascular flux (QF) can be considered as the fraction of QT exchange. Presumably, QF would change the background concentration of an impermeable tracer residing in the perfusate. Thus QF could be calculated from the relative changes in tracer concentration for any given QT. We have used Blue Dextran (1 g/l of blood) as the reference tracer. Because the minimum molecular weight of Blue Dextran is 2 X 10(6), we anticipated it to behave as an impermeable tracer in most organs. QF was simulated with continuous infusions of plasma, normal saline solution, and a 50% mixture of both. Changes in Blue Dextran concentration were continuously followed colorimetrically by changes in transmission of specific light at a wavelength of 632 nm. Because 632-nm light is affected by hematocrit and O2 saturation changes, two additional wavelengths were used: 815-nm, which is not affected by saturation or Blue Dextran concentration changes, was used to account for changes in hematocrit, and 887-nm specific light, which is not affected by Blue Dextran, served to correct for saturation changes. Red cells could not be used as the reference tracer because of the possibility of hematocrit changes independent of fluid flux (Fahraeus effect). The device so constructed proved capable of measuring rates of fluid infusion in the order of 0.1% of QT with a variability of 10% around the mean.
NASA Astrophysics Data System (ADS)
Nole, M.; Daigle, H.; Cook, A.; Malinverno, A.; Hillman, J. I. T.
2016-12-01
We explore the gas hydrate-generating capacity of diffusive methane transport induced by solubility gradients due to pore size contrasts in lithologically heterogeneous marine sediments. Through the use of 1D, 2D, and 3D reactive transport simulations, we investigate scale-dependent processes in diffusion-dominated gas hydrate systems. These simulations all track a sand body, or series of sands, surrounded by clays as they are buried through the gas hydrate stability zone. Methane is sourced by microbial methanogenesis in the clays surrounding the sand layers. In 1D, simulations performed in a Lagrangian reference frame demonstrate that gas hydrate in thin sands (3.6 m thick) can occur in high saturations (upward of 70%) at the edges of sand bodies within the upper 400 meters below the seafloor. Diffusion of methane toward the center of the sand layer depends on the concentration gradient within the sand: broader sand pore size distributions with smaller median pore sizes enhance diffusive action toward the sand's center. Incorporating downhole log- and laboratory-derived sand pore size distributions, gas hydrate saturations in the center of the sand can reach 20% of the hydrate saturations at the sand's edges. Furthermore, we show that hydrate-free zones exist immediately above and below the sand and are approximately 5 m thick, depending on the sand-clay solubility contrast. A moving reference frame is also adopted in 2D, and the angle of gravity is rotated relative to the grid system to simulate a dipping sand layer. This is important to minimize diffusive edge effects or numerical diffusion that might be associated with a dipping sand in an Eulerian grid system oriented orthogonal to gravity. Two-dimensional simulations demonstrate the tendency for gas hydrate to accumulate downdip in a sand body because of greater methane transport at depth due to larger sand-clay solubility contrasts. In 3D, basin-scale simulations illuminate how convergent sand layers in a multilayered system can compete for diffusion from clays between them, resulting in relatively low hydrate saturations. All simulations suggest that when hydrate present in clays dissociates with burial, the additional dissolved methane is soaked up by nearby sands preserving high hydrate saturations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nole, Michael; Daigle, Hugh; Cook, Ann
We explore the gas hydrate-generating capacity of diffusive methane transport induced by solubility gradients due to pore size contrasts in lithologically heterogeneous marine sediments. Through the use of 1D, 2D, and 3D reactive transport simulations, we investigate scale-dependent processes in diffusion-dominated gas hydrate systems. These simulations all track a sand body, or series of sands, surrounded by clays as they are buried through the gas hydrate stability zone. Methane is sourced by microbial methanogenesis in the clays surrounding the sand layers. In 1D, simulations performed in a Lagrangian reference frame demonstrate that gas hydrate in thin sands (3.6 m thick)more » can occur in high saturations (upward of 70%) at the edges of sand bodies within the upper 400 meters below the seafloor. Diffusion of methane toward the center of the sand layer depends on the concentration gradient within the sand: broader sand pore size distributions with smaller median pore sizes enhance diffusive action toward the sand’s center. Incorporating downhole log- and laboratory-derived sand pore size distributions, gas hydrate saturations in the center of the sand can reach 20% of the hydrate saturations at the sand’s edges. Furthermore, we show that hydrate-free zones exist immediately above and below the sand and are approximately 5 m thick, depending on the sand-clay solubility contrast. A moving reference frame is also adopted in 2D, and the angle of gravity is rotated relative to the grid system to simulate a dipping sand layer. This is important to minimize diffusive edge effects or numerical diffusion that might be associated with a dipping sand in an Eulerian grid system oriented orthogonal to gravity. Two-dimensional simulations demonstrate the tendency for gas hydrate to accumulate downdip in a sand body because of greater methane transport at depth due to larger sand-clay solubility contrasts. In 3D, basin-scale simulations illuminate how convergent sand layers in a multilayered system can compete for diffusion from clays between them, resulting in relatively low hydrate saturations. All simulations suggest that when hydrate present in clays dissociates with burial, the additional dissolved methane is soaked up by nearby sands preserving high hydrate saturations.« less
An improved artifact removal in exposure fusion with local linear constraints
NASA Astrophysics Data System (ADS)
Zhang, Hai; Yu, Mali
2018-04-01
In exposure fusion, it is challenging to remove artifacts because of camera motion and moving objects in the scene. An improved artifact removal method is proposed in this paper, which performs local linear adjustment in artifact removal progress. After determining a reference image, we first perform high-dynamic-range (HDR) deghosting to generate an intermediate image stack from the input image stack. Then, a linear Intensity Mapping Function (IMF) in each window is extracted based on the intensities of intermediate image and reference image, the intensity mean and variance of reference image. Finally, with the extracted local linear constraints, we reconstruct a target image stack, which can be directly used for fusing a single HDR-like image. Some experiments have been implemented and experimental results demonstrate that the proposed method is robust and effective in removing artifacts especially in the saturated regions of the reference image.
Plasma Jet Interactions with Liquids in Partial Fulfillment of an NRL Karles Fellowship
2015-11-30
water (DI H2O) as the reference solution, two concentrations of NaCl mixtures (0.6 Molar, and 1.0 Molar saturated NaCl), and three electroless solutions...by diffusion) to the bulk surface in net excess; that oxygen ions/radicals are being consumed from the bulk by an electrolysis path way; or that the
1994-02-01
electrochemically etched in near- saturated CaC1 2 and coated with a thermosetting plastic[13]. The quasi-reference electrode was a gold wire. The Pt(lll...annealing procedure, display arrays of small (ca 3-5 nm) terrace domains, these being separated from each other by monoatomic steps running in various
Cassidy, Cathal; Yamashita, Masao; Cheung, Martin; Kalale, Chola; Adaniya, Hidehito; Kuwahara, Ryusuke; Shintake, Tsumoru
2017-01-01
We have performed open cell transmission electron microscopy experiments through pure water vapor in the saturation pressure regime (>0.6 kPa), in a modern microscope capable of sub-Å resolution. We have systematically studied achievable pressure levels, stability and gas purity, effective thickness of the water vapor column and associated electron scattering processes, and the effect of gas pressure on electron optical resolution and image contrast. For example, for 1.3 kPa pure water vapor and 300kV electrons, we report pressure stability of ± 20 Pa over tens of minutes, effective thickness of 0.57 inelastic mean free paths, lattice resolution of 0.14 nm on a reference Au specimen, and no significant degradation in contrast or stability of a biological specimen (M13 virus, with 6 nm body diameter). We have also done some brief experiments to confirm feasibility of loading specimens into an in situ water vapor ambient without exposure to intermediate desiccating conditions. Finally, we have also checked if water experiments had any discernible impact on the microscope performance, and report pertinent vacuum and electron optical data, for reference purposes.
Adapted all-numerical correlator for face recognition applications
NASA Astrophysics Data System (ADS)
Elbouz, M.; Bouzidi, F.; Alfalou, A.; Brosseau, C.; Leonard, I.; Benkelfat, B.-E.
2013-03-01
In this study, we suggest and validate an all-numerical implementation of a VanderLugt correlator which is optimized for face recognition applications. The main goal of this implementation is to take advantage of the benefits (detection, localization, and identification of a target object within a scene) of correlation methods and exploit the reconfigurability of numerical approaches. This technique requires a numerical implementation of the optical Fourier transform. We pay special attention to adapt the correlation filter to this numerical implementation. One main goal of this work is to reduce the size of the filter in order to decrease the memory space required for real time applications. To fulfil this requirement, we code the reference images with 8 bits and study the effect of this coding on the performances of several composite filters (phase-only filter, binary phase-only filter). The saturation effect has for effect to decrease the performances of the correlator for making a decision when filters contain up to nine references. Further, an optimization is proposed based for an optimized segmented composite filter. Based on this approach, we present tests with different faces demonstrating that the above mentioned saturation effect is significantly reduced while minimizing the size of the learning data base.
NASA Astrophysics Data System (ADS)
Zhang, Yi; Nishizawa, Osamu; Kiyama, Tamotsu; Chiyonobu, Shun; Xue, Ziqiu
2014-06-01
We injected Berea sandstone with supercritical CO2 and imaged the results with a medical X-ray computed tomography (CT) scanner. The images were acquired by injecting CO2 into a core of brine-saturated sandstone (drainage), and additional images were acquired during reinjection of brine (imbibition) after drainage. We then analysed the temporal variations of CO2 saturation maps obtained from the CT images. The experiments were performed under a confining pressure of 12 MPa, a pore pressure of 10 MPa and a temperature of 40 °C. Porosity and CO2 saturation were calculated for each image voxel of the rock on the basis of the Hounsfield unit values (CT numbers) measured at three states of saturation: dry, full brine saturation and full CO2 saturation. The saturation maps indicated that the distributions of CO2 and brine were controlled by the sub-core-scale heterogeneities which consisted of a laminated structure (bedding) with high- and low-porosity layers. During drainage, CO2 preferentially flowed through the high-porosity layers where most of the CO2 was entrapped during low flow-rate imbibition. The entrapped CO2 was flushed out when high flow-rate imbibition commenced. Plots of the voxel's CT number against porosity revealed the relationship between fluid replacement and porosity. By reference to the CT numbers at the full brine-saturated stage, differential CT numbers were classified into three bins corresponding to voxel porosity: high, medium and low porosity. Distributions of the differential CT number for the three porosity bins were bimodal and in order with respect to the porosity bins during both drainage and imbibitions; however, the order differed between the two stages. This difference suggested that different replacement mechanisms operated for the two processes. Spatial autocorrelation of CO2 saturation maps on sections perpendicular to the flow direction revealed remarkable changes during passage of the replacement fronts during both drainage and imbibition, changes reflecting the interfingering pattern across the replacement fronts. Although the permeability differences between high- and low-porosity layers were not sufficiently large to disturb the uniform flow of brine, the CO2 concentration in the high-porosity layers may have been caused by the differences of capillary pressure between wide and narrow pore throats, perhaps enhanced by an invasion percolation mechanism in flow-path networks.
Miniaturized pulse oximeter sensor for continuous vital parameter monitoring
NASA Astrophysics Data System (ADS)
Fiala, Jens; Reichelt, Stephan; Werber, Armin; Bingger, Philipp; Zappe, Hans; Förster, Katharina; Klemm, Rolf; Heilmann, Claudia; Beyersdorf, Friedhelm
2007-07-01
A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cu. which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.
NASA Astrophysics Data System (ADS)
Esrael, D.; Kacem, M.; Benadda, B.
2017-07-01
We investigate how the simulation of the venting/soil vapour extraction (SVE) process is affected by the mass transfer coefficient, using a model comprising five partial differential equations describing gas flow and mass conservation of phases and including an expression accounting for soil saturation conditions. In doing so, we test five previously reported quations for estimating the non-aqueous phase liquid (NAPL)/gas initial mass transfer coefficient and evaluate an expression that uses a reference NAPL saturation. Four venting/SVE experiments utilizing a sand column are performed with dry and non-saturated sand at low and high flow rates, and the obtained experimental results are subsequently simulated, revealing that hydrodynamic dispersion cannot be neglected in the estimation of the mass transfer coefficient, particularly in the case of low velocities. Among the tested models, only the analytical solution of a convection-dispersion equation and the equation proposed herein are suitable for correctly modelling the experimental results, with the developed model representing the best choice for correctly simulating the experimental results and the tailing part of the extracted gas concentration curve.
Scrimgeour, Gemma E; Griksaitis, Michael J; Pappachan, John V; Baldock, Andrew J
2017-01-01
Children with cyanotic congenital heart disease (CCHD) live with oxyhemoglobin saturations that are typically expressed as percentages in the range of 70s and 80s. Peripheral pulse oximetry (measurement of SpO 2 ) performs poorly in this range and yet is widely used to inform clinical decisions in these patients. The reference standard is co-oximetry of arterial samples (SaO 2 ). In this study, 515 paired measurements of SpO 2 and SaO 2 were taken from 19 children who had undergone palliative cardiac surgery. SpO 2 (Masimo SET LNCS Neo pulse oximeter) overestimated oxyhemoglobin saturation in 82% of measurements (mean 4.6% ± 6.6%). There was a strong negative correlation between mean bias and SaO 2 ( r = -.96, P = .002, 95% confidence interval: -0.99 to -0.68). The results raise a concern that critical hypoxemia may go undetected and untreated if pulse oximetry is relied upon as the primary means of assessing oxyhemoglobin saturation in children with CCHD. Strong preference must be given to co-oximetry of arterial samples.
Saturation recovery EPR and ELDOR at W-band for spin labels
Froncisz, Wojciech; Camenisch, Theodore G.; Ratke, Joseph J.; Anderson, James R.; Subczynski, Witold K.; Strangeway, Robert A.; Sidabras, Jason W.; Hyde, James S.
2008-01-01
A reference-arm W-band (94 GHz) microwave bridge with two sample-irradiation arms for saturation recovery (SR) EPR and ELDOR experiments is described. Frequencies in each arm are derived from 2 GHz synthesizers that have a common time-base and are translated to 94 GHz in steps of 33 and 59 GHz. Intended applications are to nitroxide radical spin labels and spin probes in the liquid phase. An enabling technology is the use of a W-band loop-gap resonator (LGR) (J.W. Sidabras et al., Rev. Sci. Instrum. 78 (2007) 034701). The high efficiency parameter (8.2 GW−1/2 with sample) permits the saturating pump pulse level to be just 5 mW or less. Applications of SR EPR and ELDOR to the hydrophilic spin labels 3-carbamoyl-2,2,5,5-tetra-methyl-3-pyrroline-1-yloxyl (CTPO) and 2,2,6,6,-tetramethyl-4-piperidone-1-oxyl (TEMPONE) are described in detail. In the SR ELDOR experiment, nitrogen nuclear relaxation as well as Heisenberg exchange transfer saturation from pumped to observed hyperfine transitions. SR ELDOR was found to be an essential method for measurements of saturation transfer rates for small molecules such as TEMPONE. Free induction decay (FID) signals for small nitroxides at W-band are also reported. Results are compared with multifrequency measurements of T1e previously reported for these molecules in the range of 2 to 35 GHz (J.S. Hyde et al., J. Phys. Chem. B 108 (2004) 9524–9529). The values of T1e decrease at 94 GHz relative to values at 35 GHz. PMID:18547848
Illness as the saturated phenomenon: the contribution of Jean-Luc Marion.
Grīnfelde, Māra
2018-05-24
During the last few decades, many thinkers have advocated for the importance of the phenomenological approach in developing the understanding of the lived experience of illness. In their attempts, they have referred to ideas found in the history of phenomenology, most notably, in the works of Edmund Husserl, Martin Heidegger, Maurice Merleau-Ponty and Jean-Paul Sartre. The aim of this paper is to sketch out an interpretation of illness based on a yet unexplored conceptual framework of the phenomenology of French thinker Jean-Luc Marion. Focusing on concepts of the saturated phenomenon and flesh, the paper develops an interpretation of illness as the saturated phenomenon, which highlights a variety of dimensions of illness already elaborated within the phenomenology of medicine, such as the affective dimension of illness, the disruptive dimension of illness, the transformed perception of the self in illness, mineness of flesh in illness and the inexpressible and hermeneutical dimension of illness. In addition to that, the paper explores some of the consequences the proposed interpretation of illness offers regarding the nature of illness and health. It is argued that illness in its essence is very similar to the experience of other saturated phenomena, suggesting that the difference between them does not lie within the character of the affective givenness, but rather within the dynamic relationship between the affective givenness and its conceptualization. It is also shown that the experience of health is compatible with the experience of saturation and thus is not limited to the tacit and harmonious background state.
Interlaboratory Comparison of Magnetic Thin Film Measurements.
da Silva, F C S; Wang, C M; Pappas, D P
2003-01-01
A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample magnetometers, alternating-gradient force magnetometers, and superconducting quantum-interference-device magnetometers. NiFe films on Si substrates had saturation moment measurements reproduced within 5 % variation among the laboratories. The results show that a good candidate for an SRM must have a highly square hysteresis loop (m r/m s > 90 %), H c ≈ 400 A·m(-1) (5 Oe), and m s ≈ 2 × 10(-7) A·m(2) (2 × 10(-4) emu).
De Wachter, E; De Schutter, I; Meulemans, A; Buyl, R; Malfroot, A
2016-01-01
According to European and US protocols, two nasal potential difference (NPD) measurement methods are considered acceptable, although they have not been formally compared: subcutaneous agar-filled needle with calomel (Ndl) and dermal abrasion with conducting cream and Ag/AgCl electrodes (Abr). We compared both in CF and healthy volunteers (HV), assessing their discriminative value and subject's preference. Twelve classic CF and 17 HV underwent both NPD methods, performed by one operator in random order. A written questionnaire, assessing preference, was completed after each test. Tracings were coded, scored in a semi-blinded fashion and categorised as CF/non-CF. 110 tracings (56 Ndl/54 Abr) were collected: 42/110 scored CF and 68/110 non-CF, showing a good correlation. No significant preference for either method was reported. Both NPD methods are similar in terms of discriminative value and subject's preference, comparing classical CF and HV. For diagnosing CF, the operator's preferred NPD-method may be used. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Behavior of soluble and immobilized acid phosphatase in hydro-organic media.
Wan, H; Horvath, C
1975-11-20
The hydrolysis of p-nitrophenyl phosphate by wheat germ acid phosphatase (orthophosphoric monoester phosphohydrolase, EC 3.1.3.2) has been investigated in mixtures of aqueous buffers with acetone, dioxane and acetonitrile. The enzyme was either in free solution or immobilized on a pellicular support which consisted of a porous carbonaceous layer on solid glass beads. The highest enzyme activity was obtained in acetone and acetonitrile mixed with citrate buffer over a wide range of organic solvent concentration. In 50% (v/v) acetone both V and Km of the immobilized enzyme were about half of the values in the neat aqueous buffer, but the Ki for inorganic phosphate was unchanged. In 50% (v/v) mixtures of various solvents and citrate buffers of different pH, the enzymic activity was found to depend on the pH of the aqueous buffer component rather than the pH of the hydro-organic mixture as measured with the glass-calomel electrode. The relatively high rates of p-nitrophenol liberation in the presence of glucose even at high organic solvent concentrations suggest that transphosphorylation is facilitated at low water activity.
New method of extracting information of arterial oxygen saturation based on ∑ | 𝚫 |
NASA Astrophysics Data System (ADS)
Dai, Wenting; Lin, Ling; Li, Gang
2017-04-01
Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.
New method of extracting information of arterial oxygen saturation based on ∑|𝚫 |
NASA Astrophysics Data System (ADS)
Wenting, Dai; Ling, Lin; Gang, Li
2017-04-01
Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.
PHT3D-UZF: A reactive transport model for variably-saturated porous media
Wu, Ming Zhi; Post, Vincent E. A.; Salmon, S. Ursula; Morway, Eric D.; Prommer, H.
2016-01-01
A modified version of the MODFLOW/MT3DMS-based reactive transport model PHT3D was developed to extend current reactive transport capabilities to the variably-saturated component of the subsurface system and incorporate diffusive reactive transport of gaseous species. Referred to as PHT3D-UZF, this code incorporates flux terms calculated by MODFLOW's unsaturated-zone flow (UZF1) package. A volume-averaged approach similar to the method used in UZF-MT3DMS was adopted. The PHREEQC-based computation of chemical processes within PHT3D-UZF in combination with the analytical solution method of UZF1 allows for comprehensive reactive transport investigations (i.e., biogeochemical transformations) that jointly involve saturated and unsaturated zone processes. Intended for regional-scale applications, UZF1 simulates downward-only flux within the unsaturated zone. The model was tested by comparing simulation results with those of existing numerical models. The comparison was performed for several benchmark problems that cover a range of important hydrological and reactive transport processes. A 2D simulation scenario was defined to illustrate the geochemical evolution following dewatering in a sandy acid sulfate soil environment. Other potential applications include the simulation of biogeochemical processes in variably-saturated systems that track the transport and fate of agricultural pollutants, nutrients, natural and xenobiotic organic compounds and micropollutants such as pharmaceuticals, as well as the evolution of isotope patterns.
Design of a visible-light spectroscopy clinical tissue oximeter.
Benaron, David A; Parachikov, Ilian H; Cheong, Wai-Fung; Friedland, Shai; Rubinsky, Boris E; Otten, David M; Liu, Frank W H; Levinson, Carl J; Murphy, Aileen L; Price, John W; Talmi, Yair; Weersing, James P; Duckworth, Joshua L; Hörchner, Uwe B; Kermit, Eben L
2005-01-01
We develop a clinical visible-light spectroscopy (VLS) tissue oximeter. Unlike currently approved near-infrared spectroscopy (NIRS) or pulse oximetry (SpO2%), VLS relies on locally absorbed, shallow-penetrating visible light (475 to 625 nm) for the monitoring of microvascular hemoglobin oxygen saturation (StO2%), allowing incorporation into therapeutic catheters and probes. A range of probes is developed, including noncontact wands, invasive catheters, and penetrating needles with injection ports. Data are collected from: 1. probes, standards, and reference solutions to optimize each component; 2. ex vivo hemoglobin solutions analyzed for StO2% and pO2 during deoxygenation; and 3. human subject skin and mucosal tissue surfaces. Results show that differential VLS allows extraction of features and minimization of scattering effects, in vitro VLS oximetry reproduces the expected sigmoid hemoglobin binding curve, and in vivo VLS spectroscopy of human tissue allows for real-time monitoring (e.g., gastrointestinal mucosal saturation 69+/-4%, n=804; gastrointestinal tumor saturation 45+/-23%, n=14; and p<0.0001), with reproducible values and small standard deviations (SDs) in normal tissues. FDA approved VLS systems began shipping earlier this year. We conclude that VLS is suitable for the real-time collection of spectroscopic and oximetric data from human tissues, and that a VLS oximeter has application to the monitoring of localized subsurface hemoglobin oxygen saturation in the microvascular tissue spaces of human subjects.
Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study.
Hinckfuss, Kelly; Sanderson, Penelope; Loeb, Robert G; Liley, Helen G; Liu, David
2016-03-01
We aimed to test whether the use of novel pulse oximetry sounds (sonifications) better informs listeners when a neonate's oxygen saturation (SpO2) deviates from the recommended range. Variable-pitch pulse oximeters do not accurately inform clinicians via sound alone when SpO2 is outside the target range of 90% to 95% for neonates on supplemental oxygen. Risk of blindness, organ damage, and death increase if SpO2 remains outside the target range. A more informative sonification may improve clinicians' ability to maintain the target range. In two desktop experiments, nonclinicians' ability to detect SpO2 range and direction of change was tested with novel versus conventional sonifications of simulated patient data. In Experiment 1, a "shoulder" sonification used larger pitch differences between adjacent saturation percentages for SpO2 values outside the target range. In Experiment 2, a "beacon" sonification used equal-appearing pitch differences, but when SpO2 was outside the target range, a fixed-pitch reference tone from the center of the target SpO2 range preceded every fourth pulse tone. The beacon sonification improved range identification accuracy over the control display (85% vs. 60%; p < .001), but the shoulder sonification did not (55% vs. 52%). The beacon provided a distinct auditory alert and reference that significantly improved nonclinical participants' ability to identify SpO2 range. Adding a beacon to the variable-pitch pulse oximeter sound may help clinicians identify when, and by how much, a neonate's SpO2 deviates from the target range, particularly during patient transport situations when auditory information becomes essential. © 2015, Human Factors and Ergonomics Society.
Soil specific re-calibration of water content sensors for a field-scale sensor network
NASA Astrophysics Data System (ADS)
Gasch, Caley K.; Brown, David J.; Anderson, Todd; Brooks, Erin S.; Yourek, Matt A.
2015-04-01
Obtaining accurate soil moisture data from a sensor network requires sensor calibration. Soil moisture sensors are factory calibrated, but multiple site specific factors may contribute to sensor inaccuracies. Thus, sensors should be calibrated for the specific soil type and conditions in which they will be installed. Lab calibration of a large number of sensors prior to installation in a heterogeneous setting may not be feasible, and it may not reflect the actual performance of the installed sensor. We investigated a multi-step approach to retroactively re-calibrate sensor water content data from the dielectric permittivity readings obtained by sensors in the field. We used water content data collected since 2009 from a sensor network installed at 42 locations and 5 depths (210 sensors total) within the 37-ha Cook Agronomy Farm with highly variable soils located in the Palouse region of the Northwest United States. First, volumetric water content was calculated from sensor dielectric readings using three equations: (1) a factory calibration using the Topp equation; (2) a custom calibration obtained empirically from an instrumented soil in the field; and (3) a hybrid equation that combines the Topp and custom equations. Second, we used soil physical properties (particle size and bulk density) and pedotransfer functions to estimate water content at saturation, field capacity, and wilting point for each installation location and depth. We also extracted the same reference points from the sensor readings, when available. Using these reference points, we re-scaled the sensor readings, such that water content was restricted to the range of values that we would expect given the physical properties of the soil. The re-calibration accuracy was assessed with volumetric water content measurements obtained from field-sampled cores taken on multiple dates. In general, the re-calibration was most accurate when all three reference points (saturation, field capacity, and wilting point) were represented in the sensor readings. We anticipate that obtaining water retention curves for field soils will improve the re-calibration accuracy by providing more precise estimates of saturation, field capacity, and wilting point. This approach may serve as an alternative method for sensor calibration in lieu of or to complement pre-installation calibration.
NASA Astrophysics Data System (ADS)
Walton, Stephen Michael
The increased use of biofuels presents an opportunity to improve combustion performance while simultaneously reducing greenhouse gases and pollutant emissions. This work focused on improving the fundamental understanding of the auto-ignition chemistry of oxygenated reference fuel compounds. A systematic study of the effects of ester structure on ignition chemistry was performed using the University of Michigan Rapid Compression Facility. The ignition properties of the ester compounds were investigated over a broad range of pressures (P=5-20 atm) and temperatures (T=850-1150 K) which are directly relevant to advanced combustion engine strategies. Ignition delay times for five esters were determined using the RCF. The esters were selected to systematically consider the chemical structure of the compounds. Three esters were saturated: methyl butanoate, butyl methanoate, and ethyl propanoate; and two were unsaturated: methyl crotonate and methyl trans-3-hexenoate. The unsaturated esters were more reactive than their saturated counterparts, with the largest unsaturated ester, methyl trans-3-hexenoate having the highest reactivity. Two isomers of the saturated esters, butyl methanoate and ethyl propanoate, were more reactive than the isomer methyl butanoate. The results are explained if we assume that butyl methanoate and ethyl propanoate form intermediate ring structures which decompose more rapidly than esters such as methyl butanoate, which do not form ring structures. Modeling studies of the reaction chemistry were conducted for methyl butanoate and ethyl propanoate, for which detailed mechanisms were available in the literature. The new experimental data indicated that literature rate coefficients for some of the methyl butanoate/HO2 reactions were too fast. Modifying these within the theoretical uncertainties for the reaction rates, led to excellent agreement between the model predictions and the experimental data. Comparison of the modeling results with the intermediates measured during methyl butanoate ignition indicated that pathways leading to the formation of small hydrocarbons are relatively well represented in the reaction mechanism. The results of this work provide archival benchmark data for improved understanding of the dominant reaction pathways and species controlling the auto-ignition of oxygenated reference fuel compounds. These data also provide a path for continued development of chemical kinetic models to optimize practical combustion systems.
Strain localization in usnaturated soils with large deformation
NASA Astrophysics Data System (ADS)
Song, X.; Borja, R. I.
2014-12-01
Strain localization is a ubiquitous feature of granular materials undergoing nonhomogeneous deformation. In unsaturated porous media, how the localized deformation band is formed depends crucially on the degree of saturation, since fluid in the pores of a solid imposes a volume constraint on the deformation of the solid. When fluid flow is involved, the inception of the localized deformation band also depends on the heterogeneity of a material, which is quantified in terms of the spatial variation of density, the degree of saturation, and matric suction. We present a mathematical framework for coupled solid-deformation/fluid-diffusion in unsaturated porous media that takes into account material and geometric nonlinearities [1, 2]. The framework relies on the continuum principle of thermodynamics to identify an effective, or constitutive, stress for the solid matrix, and a water retention law that highlights the interdependence of degree of saturation, suction, and porosity of the material. We discuss the role of heterogeneity, quantified either deterministically or stochastically, on the development of a persistent shear band. We derive bifurcation conditions [3] governing the initiation of such a shear band. This research is inspired by current testing techniques that allow nondestructive and non-invasive measurement of density and the degree of saturation through high-resolution imaging [4]. The numerical simulations under plane strain condition demonstrate that the bifurcation not only manifests itself on the loading response curve and but also in the space of the degree of saturation, specific volume and suction stress. References[1] Song X, Borja RI, Mathematical framework for unsaturated flow in the finite deformation range. Int. J. Numer. Meth. Engng 2014; 97: 658-686. [2] Song X, Borja RI, Finite deformation and fluid flow in unsaturated soils with random heterogeneity. Vadose Zone Journal 2014; doi:10.2136/vzj2013.07.0131. [3] Song X, Borja RI, Instability and bifurcation in partially saturated porous media. 2014. to be submitted. [4] Song X, Strain localization in unsaturated porous media. 2014. Ph.D. Dissertation, Stanford University, California.
Mower, R.W.
1973-01-01
Saturated Quaternary deposits in the Sugar Horse quadrangle supply significant quantities of water to wells from which water is withdrawn for domestic, municipal, industrial, and irrigation uses. The deposits consist of clay, silt, sand, and gravel; individual beds range from a few inches to several tens of feet thick. The principal aquifer, which is almost completely within the Quaternary deposits, supplied about 4 percent, or 9,000 acre-feet, of the municipal and industrial water used annually in Salt Lake County during 1964-68.As a general rule, more water is stored and more water will be yielded to a well where aquifers are thicker. This map can be used as a general guide to those areas where greatest amounts of water are stored in the aquifer, and where yields to wells may be greater. Local variations in the ability of saturated deposits to transmit water can alter the general relationship between aquifer thickness and yield of wells.The thickness of saturated Quaternary deposits within the area of the Sugar Horse quadrangle ranges from zero to about 650 feet, as shown on the map. The thickest section of these deposits is near the southwestern corner of the quadrangle, and the thinnest section is along the mountain front adjacent to the approximate eastern limit of saturated Quaternary deposits.The thickness of saturated Quaternary deposits shown on this map is based on drillers’ logs for 55 deep wells (which show the thickness of the Quaternary deposits) and on water-level measurements made in February 1972 in wells in unconfined shallow aquifers.Reports in the following list of selected references contain other information about the saturated Quaternary deposits in this and adjacent parts of Jordan Valley, Utah. The basic-data reports and releases contain well logs, water-level measurements, and other types of basic ground-water data. The interpretive repots contain discussions of the occurrence of ground water, tests to determine hydraulic properties of the aquifer, and related information. Ground-water terms used in this report have been defined by Lohman and others (1972).
Validating a spatially distributed hydrological model with soil morphology data
NASA Astrophysics Data System (ADS)
Doppler, T.; Honti, M.; Zihlmann, U.; Weisskopf, P.; Stamm, C.
2014-09-01
Spatially distributed models are popular tools in hydrology claimed to be useful to support management decisions. Despite the high spatial resolution of the computed variables, calibration and validation is often carried out only on discharge time series at specific locations due to the lack of spatially distributed reference data. Because of this restriction, the predictive power of these models, with regard to predicted spatial patterns, can usually not be judged. An example of spatial predictions in hydrology is the prediction of saturated areas in agricultural catchments. These areas can be important source areas for inputs of agrochemicals to the stream. We set up a spatially distributed model to predict saturated areas in a 1.2 km2 catchment in Switzerland with moderate topography and artificial drainage. We translated soil morphological data available from soil maps into an estimate of the duration of soil saturation in the soil horizons. This resulted in a data set with high spatial coverage on which the model predictions were validated. In general, these saturation estimates corresponded well to the measured groundwater levels. We worked with a model that would be applicable for management decisions because of its fast calculation speed and rather low data requirements. We simultaneously calibrated the model to observed groundwater levels and discharge. The model was able to reproduce the general hydrological behavior of the catchment in terms of discharge and absolute groundwater levels. However, the the groundwater level predictions were not accurate enough to be used for the prediction of saturated areas. Groundwater level dynamics were not adequately reproduced and the predicted spatial saturation patterns did not correspond to those estimated from the soil map. Our results indicate that an accurate prediction of the groundwater level dynamics of the shallow groundwater in our catchment that is subject to artificial drainage would require a model that better represents processes at the boundary between the unsaturated and the saturated zone. However, data needed for such a more detailed model are not generally available. This severely hampers the practical use of such models despite their usefulness for scientific purposes.
Tong, Juxiu; Hu, Bill X; Yang, Jinzhong; Zhu, Yan
2016-06-01
The mixing layer theory is not suitable for predicting solute transfer from initially saturated soil to surface runoff water under controlled drainage conditions. By coupling the mixing layer theory model with the numerical model Hydrus-1D, a hybrid solute transfer model has been proposed to predict soil solute transfer from an initially saturated soil into surface water, under controlled drainage water conditions. The model can also consider the increasing ponding water conditions on soil surface before surface runoff. The data of solute concentration in surface runoff and drainage water from a sand experiment is used as the reference experiment. The parameters for the water flow and solute transfer model and mixing layer depth under controlled drainage water condition are identified. Based on these identified parameters, the model is applied to another initially saturated sand experiment with constant and time-increasing mixing layer depth after surface runoff, under the controlled drainage water condition with lower drainage height at the bottom. The simulation results agree well with the observed data. Study results suggest that the hybrid model can accurately simulate the solute transfer from initially saturated soil into surface runoff under controlled drainage water condition. And it has been found that the prediction with increasing mixing layer depth is better than that with the constant one in the experiment with lower drainage condition. Since lower drainage condition and deeper ponded water depth result in later runoff start time, more solute sources in the mixing layer are needed for the surface water, and larger change rate results in the increasing mixing layer depth.
Saturated and trans-fatty acids in UK takeaway food.
Davies, Ian Glynn; Blackham, Toni; Jaworowska, Agnieszka; Taylor, Catherine; Ashton, Matthew; Stevenson, Leonard
2016-01-01
The aim of the study was to analyze the saturated fatty acid (SFA) and trans-fatty acid (TFA) contents of popular takeaway foods in the UK (including English, pizza, Chinese, Indian and kebab cuisine). Samples of meals were analyzed by an accredited public analyst laboratory for SFA and TFA. The meals were highly variable for SFA and TFA. English and Pizza meals had the highest median amount of SFA with 35.7 g/meal; Kebab meals were high in TFA with up to 5.2 g/meal. When compared to UK dietary reference values, some meals exceeded SFA and TFA recommendations from just one meal. Takeaway food would be an obvious target to reduce SFA and TFA contents and increase the potential of meeting UK recommendations. Strategies such as reformulation and smaller takeaway portion sizes warrant investigation.
Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance
NASA Astrophysics Data System (ADS)
Setiadi, Rahmondia N.; Schilling, Meinhard
2018-05-01
An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.
Saturated CO{sub 2} absorption near 1.6 μm for kilohertz-accuracy transition frequencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burkart, Johannes, E-mail: johannes.burkart@ujf-grenoble.fr; Romanini, Daniele; Campargue, Alain
2015-05-21
Doppler-free saturated-absorption Lamb dips were measured on weak rovibrational lines of {sup 12}C{sup 16}O{sub 2} between 6189 and 6215 cm{sup −1} at sub-Pa pressures using optical feedback frequency stabilized cavity ring-down spectroscopy. By referencing the laser source to an optical frequency comb, transition frequencies for ten lines of the 30013←00001 band P-branch and two lines of the 31113←01101 hot band R-branch were determined with an accuracy of a few parts in 10{sup 11}. Involving rotational quantum numbers up to 42, the data were used for improving the upper level spectroscopic constants. These results provide a highly accurate reference frequency gridmore » over the spectral interval from 1599 to 1616 nm.« less
Yamashita, Masao; Cheung, Martin; Kalale, Chola; Adaniya, Hidehito; Kuwahara, Ryusuke; Shintake, Tsumoru
2017-01-01
We have performed open cell transmission electron microscopy experiments through pure water vapor in the saturation pressure regime (>0.6 kPa), in a modern microscope capable of sub-Å resolution. We have systematically studied achievable pressure levels, stability and gas purity, effective thickness of the water vapor column and associated electron scattering processes, and the effect of gas pressure on electron optical resolution and image contrast. For example, for 1.3 kPa pure water vapor and 300kV electrons, we report pressure stability of ± 20 Pa over tens of minutes, effective thickness of 0.57 inelastic mean free paths, lattice resolution of 0.14 nm on a reference Au specimen, and no significant degradation in contrast or stability of a biological specimen (M13 virus, with 6 nm body diameter). We have also done some brief experiments to confirm feasibility of loading specimens into an in situ water vapor ambient without exposure to intermediate desiccating conditions. Finally, we have also checked if water experiments had any discernible impact on the microscope performance, and report pertinent vacuum and electron optical data, for reference purposes. PMID:29099843
NASA Astrophysics Data System (ADS)
Mundhra, A.; Sain, K.; Shankar, U.
2012-12-01
The Indian National Gas Hydrate Program Expedition (NGHP) 01 discovered gas hydrate in unconsolidated sediments at several drilling sites along the continental margins of Krishna-Godavari Basin, India. Presence of gas hydrate reduces the attenuation of travelling seismic waves which can be measured by estimation of seismic quality factor (Dasgupta and Clark, 1998). Here, we use log spectral ratio method (Sain et al, 2009) to compute quality factor at three locations, among which two have strong and one has no bottom simulating reflector (BSR), along seismic cross-line near one of the drilling site. Interval quality factor for three submarine sedimentary layers bounded by seafloor, BSR, one reflector above and another reflector below the BSR has been measured. To compute quality factor, unprocessed pre-stack seismic data has been used to avoid any influence of processing sequence. We have estimated that interval quality factor lies within 200-220 in the interval having BSR while it varies within 90-100 in other intervals. Thereby, high interval quality factor ascertains that observed BSR is due to presence of gas hydrates. We have performed rock physics modelling by using isotropic and anisotropic models, to quantitatively estimate gas hydrate saturation at one of the location where an interval has high quality factor. Abruptly high measured resistivity and high P-wave velocity in the interval, leads to towering hydrate saturation (Archie,1942 and Helegrud et al, 1999) in comparison to lower gas hydrate saturations estimated by pressure core and chlorinity measurements. Overestimation of saturation is attributed to presence of near vertical fractures that are identified from logging-while-drilling resistivity images. We have carried out anisotropic modeling (Kennedy and Herrick, 2004 and Lee,2009) by incorporating fracture volume and fracture porosity to estimate hydrate saturation and have observed that modeled gas hydrate saturations agree with the lower gas hydrate saturations obtained from pressure core and chlorinity measurements. Therefore, we find that 1) quality factor is significantly higher in the interval bearing gas hydrates and is a useful tool to discover hydrate deposits, 2) anisotropy due to presence of near vertical hydrate filled fractures translates into elevated saturation because of high measured resistivity and velocity and 3) anisotropic model greatly corrects the saturation estimates in fractured medium. References: Archie, G.E., 1942. Petroleum Transactions of AIME, 146, 54-62. Dasgupta, R., Clark, R.A., 1998. Geophysics 63, 2120-2128. Kennedy, W.D., Herrick, D.C., 2004. Petrophysics 45, 38-58. Lee, M.W., 2009. U.S. Geological Survey Scientific Investigations Report 2009-5141, 13. Sain, K., Singh, A.K., Thakur, N.K., Khanna, R.K., 2009.Marine Geophysical Researches 30, 137-145.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houser, Kevin W.; Royer, Michael P.; David, Aurelien
A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors)more » and wavelength space (avoiding artificial increase of color rendition values by selective optimization).« less
Stahl, Marcella Aparecida; Buscato, Monise Helen Masuchi; Grimaldi, Renato; Cardoso, Lisandro Pavie; Ribeiro, Ana Paula Badan
2018-05-01
Several studies have shown that excessive intake of trans and saturated fatty acids is associated with an increased risk of cardiovascular disease. In this context, the food industry has sought alternatives for the development of healthy lipid bases, with higher levels of unsaturated fatty acids, adapting to current legislation. The incorporation of structuring agents into liquid oils has proven to be a potential alternative for obtaining semi-plastic lipid bases with reduced levels of saturated fatty acids. Thus, the objective of this study was to produce zero trans fat bases with lower saturated fatty acids levels. Palm oil (PO) was used as a zero trans-lipid base reference because of its technological functionality. Blends containing different proportions of high oleic sunflower oil (HOSO) and PO were prepared as follows: control 100: 0; 80:20; 60:40; 40:60; 20:80; and 100: 0 PO: HOSO (w/w%), respectively. Then, 3% of fully hydrogenated crambe oil (FHCO) and 3% sorbitan monostearate (SMS) were added to the blends as structuring agents, forming the structured (S) blends. The addition of HOSO to the PO decreased the saturated fatty acids by up to 30.6%, with consequent increase of unsaturated fatty acids, especially oleic acid. The joint action of the SMS and the FCHO allowed for obtaining structured blends with plastic and spreadability characteristics, as well as modifications throughout the crystallization process of the original blends. Copyright © 2018 Elsevier Ltd. All rights reserved.
A new curvature compensation technique for CMOS voltage reference using |VGS| and ΔVBE
NASA Astrophysics Data System (ADS)
Xuemin, Li; Mao, Ye; Gongyuan, Zhao; Yun, Zhang; Yiqiang, Zhao
2016-05-01
A new mixed curvature compensation technique for CMOS voltage reference is presented, which resorts to two sub-references with complementary temperature characteristics. The first sub-reference is the source-gate voltage |VGS|p of a PMOS transistor working in the saturated region. The second sub-reference is the weighted sum of gate-source voltages |VGS|n of NMOS transistors in the subthreshold region and the difference between two base-emitter voltages ΔVBE of bipolar junction transistors (BJTs). The voltage reference implemented utilizing the proposed curvature compensation technique exhibits a low temperature coefficient and occupies a small silicon area. The proposed technique was verified in 0.18 μm standard CMOS process technology. The performance of the circuit has been measured. The measured results show a temperature coefficient as low as 12.7 ppm/°C without trimming, over a temperature range from -40 to 120 °C, and the current consumption is 50 μA at room temperature. The measured power-supply rejection ratio (PSRR) is -31.2 dB @ 100 kHz. The circuit occupies an area of 0.045 mm2. Project supported by the National Natural Science Foundation of China (No. 61376032).
Loading Rate Effects on the One-Dimensional Compressibility of Four Partially Saturated Soils
1986-12-01
representations are referred to as constitutive models. Numerous constitutive models incorporating loading rate effects have been developed ( Baladi and Rohani...and probably more indicative of the true values of applied pressure and average strain produced during the test. A technique developed by Baladi and...Sand," Technical Report No. AFWL-TR-66-146, Air Force Weapons Laboratory, Kirtland Air Force Base, New Mexico, June, 1967. 4. Baladi , George Y., and
NASA Astrophysics Data System (ADS)
Ibey, Bennett; Subramanian, Hariharan; Ericson, Nance; Xu, Weijian; Wilson, Mark; Cote, Gerard L.
2005-03-01
A blood perfusion and oxygenation sensor has been developed for in situ monitoring of transplanted organs. In processing in situ data, motion artifacts due to increased perfusion can create invalid oxygenation saturation values. In order to remove the unwanted artifacts from the pulsatile signal, adaptive filtering was employed using a third wavelength source centered at 810nm as a reference signal. The 810 nm source resides approximately at the isosbestic point in the hemoglobin absorption curve where the absorbance of light is nearly equal for oxygenated and deoxygenated hemoglobin. Using an autocorrelation based algorithm oxygenation saturation values can be obtained without the need for large sampling data sets allowing for near real-time processing. This technique has been shown to be more reliable than traditional techniques and proven to adequately improve the measurement of oxygenation values in varying perfusion states.
Zhang, Shu-Xin; Chai, Xin-Sheng; He, Liang
2016-09-16
This work reports on a method for the accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography (HS-GC) method. The method was based the HS-GC measurement of water vapor on a set closed vials containing in a given amount pulp with different amounts of water addition, from under-saturation to over-saturation. By plotting the equilibrated water vapor signal vs. the amount of water added in pulp, two different trend lines can be observed, in which the transition of the lines corresponds to fiber water-retaining capability. The results showed that the HS-GC method has good measurement precision (much better than the reference method) and good accuracy. The present method can be also used for determining pulp fiber water-retaining capability at the process temperatures in both laboratory research and mill applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Spontaneous Imbibition in Low Permeability Medium, SUPRI TR-114
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovscek, Anthony R.; Schembre, Josephina
1999-08-09
A systematic experimental investigation of capillary pressure characteristics and fluid flow in diatomite was begun. Using an X-ray CT scanner and a specially constructed imbibition cell, we study spontaneous water imbibition processes in diatomite and, for reference, Berea sandstone and chalk. The mass of water imbibed as a function of time is also measured. Imbibition is restricted to concurrent flow. Despite a marked difference in rock properties such as permeability and porosity, we find similar trends in saturation profiles and weight gain versus time functions. Imbibition in diatomote is relatively rapid when initial water saturation is low due to largemore » capillary forces. Using a non-linear regression analysis together with the experimental data, the capillary pressure and water relative permeability curves are determined for the diatomite in the water-air system. The results given for displacement profiles by numerical simulation match the experimental results.« less
Dependence of pedestal properties on plasma parameters
NASA Astrophysics Data System (ADS)
Kim, S. K.; Na, Y.-S.; Saarelma, S.; Kwon, O.
2018-01-01
We have numerically investigated the dependence of pedestal properties such as the pedestal height and the pedestal width on various global parameters using the EURO-DEMO as the reference equilibrium. We have used EPED, a predictive model of the edge pedestal. Among global parameters, we have chosen to vary the triangularity, δ , the elongation, κ , and the poloidal beta, {{β }p} , which have larger effects on the pedestal properties. Improvement of pedestal properties can be achieved for more shaped plasma boundary. However, the increase in the pedestal height and the width with δ saturates around δ ∼ 0.6. Also, the pedestal width saturates and the pedestal temperature starts to decrease for κ >1.9 . Improvement of the pedestal properties due to δ is larger at higher poloidal beta. The pedestal width slightly increases with the electron density at the pedestal top and the effective charge number.
Analysis and modeling of a family of two-transistor parallel inverters
NASA Technical Reports Server (NTRS)
Lee, F. C. Y.; Wilson, T. G.
1973-01-01
A family of five static dc-to-square-wave inverters, each employing a square-loop magnetic core in conjunction with two switching transistors, is analyzed using piecewise-linear models for the nonlinear characteristics of the transistors, diodes, and saturable-core devices. Four of the inverters are analyzed in detail for the first time. These analyses show that, by proper choice of a frame of reference, each of the five quite differently appearing inverter circuits can be described by a common equivalent circuit. This equivalent circuit consists of a five-segment nonlinear resistor, a nonlinear saturable reactor, and a linear capacitor. Thus, by proper interpretation and identification of the parameters in the different circuits, the results of a detailed solution for one of the inverter circuits provide similar information and insight into the local and global behavior of each inverter in the family.
Neonatal Transport - Experience of a Tertiary Care Hospital of Bangladesh.
Dey, S K; Sharker, S; Jahan, I; Moni, S C; Shabuj, K H; Chisti, M J; Mannan, M A; Shahidullah, M
2017-01-01
Safe transportation is mostly an unnoticed neonatal health issue in Bangladesh and no documentation is available regarding the existing practices. So this study was intended to document transport status of the referred newborn to a tertiary care hospital. This observational study included 150 out born neonates over 12 months period transported from various places to NICU, Bangabandhu Sheikh Mujib Medical University (BSMMU) from May 2015 to April 2016. A structured data collection form was used to record information categorized into pre-transport, during transport and at admission. At admission detailed clinical assessment of the baby was done and recorded. Outcome was determined as discharge or death. Of 150 transported neonates, two-third were preterm 115(77%) & LBW 113(75%). Common indications for referral were prematurity and sepsis. Most of the patients were referred from private hospital 107(71%). Majority of newborns (86%) were referred from hospitals of Dhaka city while only 14% were referred from outside Dhaka. Referral notes were supplied in most of the cases 134(89%) but comprehensive information was obtainable only in 3 cases. Although main transport vehicle was ambulance 130(87%), medical personnel accompanied the sick baby only in 6(4%) of cases. The distance traveled was less than 10 kilometers (kms) in 95(63%) and more than 100 km in 10(7%) of enrolled neonates. Transport time was less than 1 hour in 72(48%), 1-6 hours in 66(44%) and more than 6 hours in 12(8%) of cases. Nearly two third of newborn were transported after office period, 107(72%). At admission 21(14%) babies had hypothermia, 8(7.62%) hypoglycemia, 16(11%), poor perfusion 28(19%), low saturation 27(18%). Hyperthermia & hyperglycemia were observed in 8(5%) & 7(5%) cases respectively. Of the total 150 babies referred, 17(11%) died. While comparing with discharged newborn, died newborn were more frequent sufferer of hypothermia (p value 0.007) and low saturation (p value 0.049) at admission. Premature, low birth weight and sick newborns are being transported despite lack of safe transport system.
Activation analyses of authenticated hairs of Napoleon Bonaparte confirm arsenic poisoning.
Weider, B; Fournier, J H
1999-12-01
In 1960, activation analyses at the Harwell Nuclear Research Laboratory of the University of Glascow, London of authenticated hairs of Napoleon Bonaparte taken immediately after his death confirmed Napoleon's chronic arsenic poisoning on the island of St. Helena. Timeline correlation of his clinical symptomatology of the preceding 4 months, as reported in the written diaries of his exiled companions, further supports the effect of fluctuating, elevated toxic levels of arsenic on his health. Independent analyses of authenticated hairs of Napoleon by the Toxicology Crime Laboratory of the United States Federal Bureau of Investigation in 1995 reveals toxic levels of arsenic. The successful assassination of Napoleon included both a cosmetic and lethal phase. The cosmetic phase consisted of arsenic poisoning over time to weaken Napoleon, making the associated debility appear to be a natural illness and thus allay any suspicions prior to instituting the lethal phase. On May 3, 1821, at 5:30 P.M., the lethal phase was carried out. Napoleon was given Calomel (HgCl), a cathartic, and a popular orange-flavored drink called orgeat, which was flavored with the oil of bitter almonds. Together they formed mercury cyanide, which is lethal. Napoleon lost consciousness and died two days later.
Cortés-Gutiérrez, Elva I; Cerda-Flores, Ricardo M; González-Ramírez, Diego; Zúñiga-Charles, Miguel A; Lazcano-Martínez, Sigifredo; Sampayo-Reyes, Adriana; Leal-Garza, Carlos H
2004-05-01
The aims of this study were to evaluate the mutagenic and cytotoxic activity of mercurous chloride by the micronucleus technique in vivo on the bone marrow of golden Syrian hamsters after a single i.p. drug administration. Forty male golden Syrian hamsters were classified into eight groups: negative control, positive control and six groups treated with different doses of mercurous chloride (1.25, 2.5, 5, 10, 20 and 40 mg/kg). The negative control was injected with physiological saline i.p. and the positive control with cyclophosphamide at a dose of 80 mg/kg i.p. With respect to mutagenic effect, the average number of micronucleated polychromatic erythrocytes (MPE) in hamsters treated with different doses of mercurous chloride was not significant compared with the negative control. With respect to cytotoxic effect, the average polychromatic erythrocyte/red blood cell ratio showed a significant decrease when the doses were higher than the 2.5 mg/kg dose compared with the negative control. In conclusion, this preliminary study shows a cytotoxic effect but not a mutagenic effect of calomel in vivo at one time point (24 h).
Proof of concept non-invasive estimation of peripheral venous oxygen saturation.
Khan, Musabbir; Pretty, Chris G; Amies, Alexander C; Balmer, Joel; Banna, Houda E; Shaw, Geoffrey M; Geoffrey Chase, J
2017-05-19
Pulse oximeters continuously monitor arterial oxygen saturation. Continuous monitoring of venous oxygen saturation (SvO 2 ) would enable real-time assessment of tissue oxygen extraction (O 2 E) and perfusion changes leading to improved diagnosis of clinical conditions, such as sepsis. This study presents the proof of concept of a novel pulse oximeter method that utilises the compliance difference between arteries and veins to induce artificial respiration-like modulations to the peripheral vasculature. These modulations make the venous blood pulsatile, which are then detected by a pulse oximeter sensor. The resulting photoplethysmograph (PPG) signals from the pulse oximeter are processed and analysed to develop a calibration model to estimate regional venous oxygen saturation (SpvO 2 ), in parallel to arterial oxygen saturation estimation (SpaO 2 ). A clinical study with healthy adult volunteers (n = 8) was conducted to assess peripheral SvO 2 using this pulse oximeter method. A range of physiologically realistic SvO 2 values were induced using arm lift and vascular occlusion tests. Gold standard, arterial and venous blood gas measurements were used as reference measurements. Modulation ratios related to arterial and venous systems were determined using a frequency domain analysis of the PPG signals. A strong, linear correlation (r 2 = 0.95) was found between estimated venous modulation ratio (R Ven ) and measured SvO 2 , providing a calibration curve relating measured R Ven to venous oxygen saturation. There is a significant difference in gradient between the SpvO 2 estimation model (SpvO 2 = 111 - 40.6*R) and the empirical SpaO 2 estimation model (SpaO 2 = 110 - 25*R), which yields the expected arterial-venous differences. Median venous and arterial oxygen saturation accuracies of paired measurements between pulse oximeter estimated and gold standard measurements were 0.29 and 0.65%, respectively, showing good accuracy of the pulse oximeter system. The main outcome of this study is the proof of concept validation of a novel pulse oximeter sensor and calibration model to assess peripheral SvO 2 , and thus O 2 E, using the method used in this study. Further validation, improvement, and application of this model can aid in clinical diagnosis of microcirculation failures due to alterations in oxygen extraction.
Siega-Riz, Anna Maria; Haugen, Margaretha; Meltzer, Helle M; Von Holle, Ann; Hamer, Robert; Torgersen, Leila; Knopf-Berg, Cecilie; Reichborn-Kjennerud, Ted; Bulik, Cynthia M
2008-05-01
Little is known concerning the dietary habits during pregnancy of women with eating disorders that may lie in the causal pathway of adverse birth outcomes. We examined the nutrient and food group intakes of women with bulimia nervosa and binge-eating disorder during pregnancy and compared these with intakes of women with no eating disorders. Data on 30,040 mother-child pairs from the prospective Norwegian Mother and Child Cohort Study were used in cross-sectional analyses. Dietary information was collected by using a food-frequency questionnaire during the first half of pregnancy. Statistical testing by eating disorder categories with the non-eating-disorder category as the referent group was conducted by using log means adjusted for confounding and multiple comparisons. Food group differences were analyzed by using a Wilcoxon's two-sided normal approximation test that was also adjusted for multiple comparisons. Women with binge-eating disorder before and during pregnancy had higher intakes of total energy, total fat, monounsaturated fat, and saturated fat, and lower intakes of folate, potassium, and vitamin C than the referent (P < 0.02). Women with incident binge-eating disorder during pregnancy had higher intakes of total energy and saturated fat than the referent (P = 0.01). Several differences emerged in food group consumption between women with and without eating disorders, including intakes of artificial sweeteners, sweets, juice, fruit, and fats. Women with bulimia nervosa before and during pregnancy and those with binge-eating disorder before pregnancy exhibit dietary patterns that differ from those in women without eating disorders, that are reflective of their symptomatology, and that may influence pregnancy outcomes.
Oxygen Saturation in Healthy Children Aged 5 to 16 Years Residing in Huayllay, Peru at 4340 m
Schult, Sandra
2011-01-01
Abstract Schult, Sandra, and Carlos Canelo-Aybar. Oxygen saturation in healthy chidren aged 5 to 6 years residing in Huayllay, Peru, at 4340 m. High Alt. Med. Biol. 12:89–92, 2011.—Hypoxemia is a major life-threatening complication of childhood pneumonia. The threshold points for hypoxemia vary with altitude. However, few published data describe that normal range of variation. The purpose of this study was to establish reference values of normal mean Sao2 levels and an approximate cutoff point to define hypoxemia for clinical purposes above 4300 meters above sea level (masl). Children aged 5 to 16 yr were examined during primary care visits at the Huayllay Health Center. Huayllay is a rural community located at 4340 m in the province of Pasco in the Peruvian Andes. We collected basic sociodemographic data and evaluated three outcomes: arterial oxygen saturation (Sao2) with a pulse oximeter, heart rate, and respiratory rate. Comparisons of main outcomes among age groups (5–6, 7–8, 9–10, 11–12, 13–14, and 15–16 yr) and sex were performed using linear regression models. The correlation of Sao2 with heart rate and respiration rate was established by Pearson's correlation test. We evaluated 583 children, of whom 386 were included in the study. The average age was 10.3 yr; 55.7% were female. The average Sao2, heart rate, and respiratory rate were 85.7% (95% CI: 85.2–86.2), 80.4/min (95% CI: 79.0–81.9), and 19.9/min (95% CI: 19.6–20.2), respectively. Sao2 increased with age (p < 0.001). No differences by sex were observed. The mean minus two standard deviations of Sao2 (threshold point for hypoxemia) ranged from 73.8% to 81.8% by age group. At 4300 m, the reference values for hypoxemia may be 14.2% lower than at sea level. This difference must be considered when diagnosing hypoxemia or deciding oxygen supplementation at high altitude. Other studies are needed to determine whether this reference value is appropriate for clinical use. PMID:21452970
Kanz, P; Krieger, S; Drillich, M; Iwersen, M
2018-07-01
Pulse oximetry is a well-established technique in human and veterinary medicine. In farm animals, it could also be a useful tool for the detection of critical conditions relating to oxygen supply and the cardiovascular system. Among other uses, an innovative application could be the monitoring of fetuses during birth. This could help in the early identification of critical situations and support farmers and veterinarians in their decision to start obstetric or life-support interventions. Until now, however, its use in ruminant medicine was still limited to experimental applications. The objective of this study was to evaluate the accuracy of the Radius-7 Wearable Pulse CO-Oximeter (Masimo Corporation, Irvine, CA) for monitoring vital parameters in newborn calves. All measurements were conducted on animals in the lying down position. The sensor of the pulse oximeter was placed in the interdigital space of the calves' front legs and fixed with a homemade latex hoof cover. The pulsoximetric measurements of arterial oxygen saturation (SpO 2 ) in 40 newborn calves were compared with the corresponding results (SaO 2 ) from a portable blood gas analyzer (VetScan iStat1, Abaxis Inc., Union City, CA), which served as the reference. For this, an arterial blood sample was taken from the medial intermediate branch of the caudal auricular artery. In addition, the pulse rate was measured in 10 calves aged between 0 and 7 d with the pulse oximeter and simultaneously with a heart rate belt (Polar Equine Belt, Polar Electro Oy, Kempele, Finland) to determine their level of agreement. Spearman correlation coefficient for oxygen saturation was 93.8% for the pulse oximeter and the blood gas analyzer, and 97.7% for the pulse rate measured with the pulse oximeter and the heart rate belt. Bland-Altman plots revealed an overestimation of SaO 2 by 2.95 ± 6.39% and an underestimation of the pulse rate by -0.41 ± 3.18 beats per minute compared with the corresponding reference methods. In summary, the pulse oximeter is suitable for continuous monitoring of arterial oxygen saturation and pulse in newborn Holstein Friesian calves. For practical use, purpose-built technical equipment is required to attach the sensor to the calves' legs. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Discrimination of enclosed images by weighted storage in an optical associative memory
NASA Astrophysics Data System (ADS)
Duelli, M.; Cudney, R. S.; Günter, P.
1996-02-01
We present an all-optical associative memory that can distinguish objects that are enclosed by or strongly overlap other objects. This is done by appropriately weighting the exposure of the stored images during recording. The images to be recalled associatively are stored in a photorefractive LiNbO 3 crystal via angular multiplexing. Thresholding of the reconstructed reference beams during associative readout is achieved by using a saturable absorber with an intensity tunable threshold.
Self-Organized Stationary States of Tokamaks
Jardin, S. C.; Ferraro, N.; Krebs, I.
2015-11-17
We demonstrate that in a 3D resistive magnetohydrodynamic (MHD) simulation, for some parameters it is possible to form a stationary state in a tokamak where a saturated interchange mode in the center of the discharge drives a near helical flow pattern that acts to non-linearly sustain the configuration by adjusting the central loop voltage through a dynamo action. This could explain the physical mechanism for maintaining stationary non-sawtoothing “hybrid” discharges, often referred to as “flux-pumping”.
Ultra-low-cost clinical pulse oximetry.
Petersen, Christian L; Gan, Heng; MacInnis, Martin J; Dumont, Guy A; Ansermino, J Mark
2013-01-01
An ultra-low-cost pulse oximeter is presented that interfaces a conventional clinical finger sensor with a mobile phone through the headset jack audio interface. All signal processing is performed using the audio subsystem of the phone. In a preliminary volunteer study in a hypoxia chamber, we compared the oxygen saturation obtained with the audio pulse oximeter against a commercially available (and FDA approved) reference pulse oximeter (Nonin Xpod). Good agreement was found between the outputs of the two devices.
Construction of an almond linkage map in an Australian population Nonpareil × Lauranne
2010-01-01
Background Despite a high genetic similarity to peach, almonds (Prunus dulcis) have a fleshless fruit and edible kernel, produced as a crop for human consumption. While the release of peach genome v1.0 provides an excellent opportunity for almond genetic and genomic studies, well-assessed segregating populations and the respective saturated genetic linkage maps lay the foundation for such studies to be completed in almond. Results Using an almond intraspecific cross between 'Nonpareil' and 'Lauranne' (N × L), we constructed a moderately saturated map with SSRs, SNPs, ISSRs and RAPDs. The N × L map covered 591.4 cM of the genome with 157 loci. The average marker distance of the map was 4.0 cM. The map displayed high synteny and colinearity with the Prunus T × E reference map in all eight linkage groups (G1-G8). The positions of 14 mapped gene-anchored SNPs corresponded approximately with the positions of homologous sequences in the peach genome v1.0. Analysis of Mendelian segregation ratios showed that 17.9% of markers had significantly skewed genotype ratios at the level of P < 0.05. Due to the large number of skewed markers in the linkage group 7, the potential existence of deleterious gene(s) was assessed in the group. Integrated maps produced by two different mapping methods using JoinMap® 3 were compared, and their high degree of similarity was evident despite the positional inconsistency of a few markers. Conclusions We presented a moderately saturated Australian almond map, which is highly syntenic and collinear with the Prunus reference map and peach genome V1.0. Therefore, the well-assessed almond population reported here can be used to investigate the traits of interest under Australian growing conditions, and provides more information on the almond genome for the international community. PMID:20932335
Ruiz, J M; Romero, J
2003-12-01
The light-limitation hypothesis was tested to assess whether water turbidity had caused the decline of a Mediterranean Posidonia oceanica (L.) Delile meadow in an area affected by a harbor. The annual growth, photosynthesis and rhizome starch concentrations of seagrass were measured and related to changes in light availability and dissolved nutrient concentration along a gradient of meadow degradation from areas close to the harbor outwards. Environmental and plant variables were measured in three stations placed along this gradient and compared with a reference station at an undisturbed meadow. The light attenuation coefficient (k) increased toward the inner harbor area, mainly due to sediment resuspension. The shoot density and leaf productivity of P. oceanica shoots were much lower in disturbed stations of the inner harbor area than in the outer, less disturbed station and the reference meadow. However, daily leaf carbon gains, calculated from the photosynthetic rates at saturating irradiance (P(max)) and the daily period in which seagrass receives light higher than its saturating irradiance (H(sat)), suggested positive C-balance in all stations. This was partly explained by photo-acclimatization of seagrass to the reduced light availability at the disturbed harbor stations (inner and intermediate), as indicated by the lengthening of H(sat) and the decrease in saturating irradiance (I(sat)) and respiratory demands. Despite photo-acclimatization, disturbed harbor stations showed less positive C-balance, seen not only in their lower leaf growth and biomass but also in a decrease in rhizome carbohydrate reserves (starch). Our results suggest that light reduction account for the reduced seagrass productivity and abundance. However, meadow decline (in terms of shoot mortality) in the harbor area is well above that predicted from similar light environments of nearby meadows or simulated in shading experiments. Thus, there are other factors than light limitation involved in seagrass mortality, most probably through more complex interactions (e.g. nutrient-epiphytes-grazers, water quality--siltation).
2011-01-01
Background Obesity is increasing in Bahrain and there is lack of information on the energy and macronutrient intake of children. The objective of this research was to study the energy and macronutrient intake as well as food frequency pattern of Bahraini school children. Methods This is a cross-sectional descriptive study conducted on Bahraini school boys and girls aged 6-18 years from all the 11 populated regions of the country. Data on food intake consisted of a 24-hour dietary recall and was obtained by interviewing a sub-sample of the study population. Information was also obtained through a self-administered questionnaire for the entire sample on the weekly frequency of food items that were grouped into 7 categories based on similarity of nutrient profiles. Dietary analysis was performed using the Nutritionist 5 (First Data Bank Version 1.6 1998). Results While the average energy intake of students was close to the Estimated Average Requirements of the UK Reference standards, protein intake substantially exceeded the Reference Nutrient Intake values as did daily sugar consumption. Dietary fiber fell short of the Dietary Recommended Values (UK) and 36%-50% students exceeded the Energy % limits for total fat, saturated fat and cholesterol. The Polyunsaturated: Saturated fat ratio remained at an unacceptable level of 0.6 for girls and boys. While sweets, snacks and regular soda drinks were popular, milk, fruits and vegetables were not commonly consumed. Conclusions High sugar consumption, low intake of dietary fiber and high energy % of saturated fat and dietary cholesterol by many Bahraini children, is likely to increase their risk of obesity and cardiovascular diseases in later life. Nutrition education programs in schools should emphasize the importance of healthy balanced diets for growth and health maintenance of children as well as dietary prevention of diseases. PMID:21645325
Mebius, Mirthe J; van der Laan, Michelle E; Verhagen, Elise A; Roofthooft, Marcus Tr; Bos, Arend F; Kooi, Elisabeth Mw
2016-12-01
Evidence suggests that hypoxic-ischemic brain injury in infants with congenital heart disease already occurs during early life. The aim of our study was, therefore, to assess the course of regional cerebral oxygen saturation (r c SO 2 ) and fractional tissue oxygen extraction (FTOE) during the first 72h after birth in infants with prenatally diagnosed duct-dependent congenital heart disease. In addition, we identified clinical parameters that were associated with r c SO 2 . We included 56 infants with duct-dependent congenital heart disease. We measured arterial oxygen saturation (SpO 2 ) and r c SO 2 during the first 72h after birth. Simultaneously, we calculated FTOE. We observed median r c SO 2 values of approximately 60%, a decreasing FTOE from 0.34 on day 1 to 0.28 on day 3 and stable preductal SpO 2 values around 90%. Several clinical variables were associated with r c SO 2 . In a multiple linear regression model only type of CHD and preductal SpO 2 were significant predictors of r c SO 2 during the first three days after birth. Infants with a duct-dependent pulmonary circulation had up to 12% lower r c SO 2 values than infants with a duct-dependent systemic circulation. We demonstrated that, during the first three days after birth, cerebral oxygen saturation is low in infants with duct-dependent congenital heart disease. Furthermore, this study provides preoperative reference values of r c SO 2 and FTOE in infants with duct-dependent CHD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Sharma, Vishaldeep; Abdelaziz, Omar
In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. This paper reports one of the Oak Ridge National Laboratory (ORNL) contributions to AREP. It compares performance of alternative refrigerants to that of R-410A and R-404A for heat pump and medium temperature applications, respectively. The alternatives reported in this paper are: R-32, DR-5, and L-41a for R-410A andmore » ARM-31a, D2Y-65, L-40, and a mixture of R-32 and R-134a for R-404A. All performance comparison tests were conducted using scroll compressors of ~1.85 tons (6.5 kW) cooling capacity. Tests were conducted over a range of combinations of saturation suction and saturation discharge temperatures for both compressors. The tests showed that, in general, energy efficiency ratio (EER) and cooling capacity of R-410A alternative refrigerants were slightly lower than that of the baseline refrigerant with a moderate increases in discharge temperature. On the other hand, R-404A alternative refrigerants showed relative performance dependence on saturation suction and saturation discharge temperatures and larger increases in discharge temperature than for the R-410A alternatives. This paper summarizes the relative performance of all alternative refrigerants compared to their respective baseline.« less
A new adjustable gains for second order sliding mode control of saturated DFIG-based wind turbine
NASA Astrophysics Data System (ADS)
Bounadja, E.; Djahbar, A.; Taleb, R.; Boudjema, Z.
2017-02-01
The control of Doubly-Fed induction generator (DFIG), used in wind energy conversion, has been given a great deal of interest. Frequently, this control has been dealt with ignoring the magnetic saturation effect in the DFIG model. The aim of the present work is twofold: firstly, the magnetic saturation effect is accounted in the control design model; secondly, a new second order sliding mode control scheme using adjustable-gains (AG-SOSMC) is proposed to control the DFIG via its rotor side converter. This scheme allows the independent control of the generated active and reactive power. Conventionally, the second order sliding mode control (SOSMC) applied to the DFIG, utilize the super-twisting algorithm with fixed gains. In the proposed AG-SOSMC, a simple means by which the controller can adjust its behavior is used. For that, a linear function is used to represent the variation in gain as a function of the absolute value of the discrepancy between the reference rotor current and its measured value. The transient DFIG speed response using the aforementioned characteristic is compared with the one determined by using the conventional SOSMC controller with fixed gains. Simulation results show, accurate dynamic performances, quicker transient response and more accurate control are achieved for different operating conditions.
Wireless Monitoring of Liver Hemodynamics In Vivo
Akl, Tony J.; Wilson, Mark A.; Ericson, M. Nance; ...
2014-07-14
Liver transplants have their highest failure rate in the first two weeks following surgery. There are no devices for continuous, real-time monitoring of the graft, currently. Here, we present a continuous perfusion and oxygen consumption monitor based on photoplethysmography. The sensor is battery operated and communicates wirelessly with a data acquisition computer which provides the possibility of implantation provided sufficient miniaturization. In two in vivo porcine studies, the sensor tracked perfusion changes in hepatic tissue during vascular occlusions with a root mean square error (RMSE) of 0.125 mL/min/g of tissue. We show the possibility of using the pulsatile wave tomore » measure the arterial oxygen saturation similar to pulse oximetry. This signal is used as a feedback to extract the venous oxygen saturation from the DC levels. Arterial and venous oxygen saturation changes were measured with an RMSE of 2.19 and 1.39% respectively when no vascular occlusions were induced. The resulting error increased to 2.82 and 3.83% when vascular occlusions were induced during hypoxia. These errors are similar to the resolution of the oximetry catheter used as a reference. This work is the first realization of a wireless perfusion and oxygenation sensor for continuous monitoring of hepatic perfusion and oxygenation changes.« less
NASA Astrophysics Data System (ADS)
Xu, Xueping; Han, Qinkai; Chu, Fulei
2018-03-01
The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.
Lee, Myung W.
2005-01-01
In order to assess the resource potential of gas hydrate deposits in the North Slope of Alaska, 3-D seismic and well data at Milne Point were obtained from BP Exploration (Alaska), Inc. The well-log analysis has three primary purposes: (1) Estimate gas hydrate or gas saturations from the well logs; (2) predict P-wave velocity where there is no measured P-wave velocity in order to generate synthetic seismograms; and (3) edit P-wave velocities where degraded borehole conditions, such as washouts, affected the P-wave measurement significantly. Edited/predicted P-wave velocities were needed to map the gas-hydrate-bearing horizons in the complexly faulted upper part of 3-D seismic volume. The estimated gas-hydrate/gas saturations from the well logs were used to relate to seismic attributes in order to map regional distribution of gas hydrate inside the 3-D seismic grid. The P-wave velocities were predicted using the modified Biot-Gassmann theory, herein referred to as BGTL, with gas-hydrate saturations estimated from the resistivity logs, porosity, and clay volume content. The effect of gas on velocities was modeled using the classical Biot-Gassman theory (BGT) with parameters estimated from BGTL.
Pettit, Laura R; Smart, Christopher W; Hart, Malcolm B; Milazzo, Marco; Hall-Spencer, Jason M
2015-05-01
Ocean acidification causes biodiversity loss, alters ecosystems, and may impact food security, as shells of small organisms dissolve easily in corrosive waters. There is a suggestion that photosynthetic organisms could mitigate ocean acidification on a local scale, through seagrass protection or seaweed cultivation, as net ecosystem organic production raises the saturation state of calcium carbonate making seawater less corrosive. Here, we used a natural gradient in calcium carbonate saturation, caused by shallow-water CO2 seeps in the Mediterranean Sea, to assess whether seaweed that is resistant to acidification (Padina pavonica) could prevent adverse effects of acidification on epiphytic foraminifera. We found a reduction in the number of species of foraminifera as calcium carbonate saturation state fell and that the assemblage shifted from one dominated by calcareous species at reference sites (pH ∼8.19) to one dominated by agglutinated foraminifera at elevated levels of CO2 (pH ∼7.71). It is expected that ocean acidification will result in changes in foraminiferal assemblage composition and agglutinated forms may become more prevalent. Although Padina did not prevent adverse effects of ocean acidification, high biomass stands of seagrass or seaweed farms might be more successful in protecting epiphytic foraminifera.
Pettit, Laura R; Smart, Christopher W; Hart, Malcolm B; Milazzo, Marco; Hall-Spencer, Jason M
2015-01-01
Ocean acidification causes biodiversity loss, alters ecosystems, and may impact food security, as shells of small organisms dissolve easily in corrosive waters. There is a suggestion that photosynthetic organisms could mitigate ocean acidification on a local scale, through seagrass protection or seaweed cultivation, as net ecosystem organic production raises the saturation state of calcium carbonate making seawater less corrosive. Here, we used a natural gradient in calcium carbonate saturation, caused by shallow-water CO2 seeps in the Mediterranean Sea, to assess whether seaweed that is resistant to acidification (Padina pavonica) could prevent adverse effects of acidification on epiphytic foraminifera. We found a reduction in the number of species of foraminifera as calcium carbonate saturation state fell and that the assemblage shifted from one dominated by calcareous species at reference sites (pH ∼8.19) to one dominated by agglutinated foraminifera at elevated levels of CO2 (pH ∼7.71). It is expected that ocean acidification will result in changes in foraminiferal assemblage composition and agglutinated forms may become more prevalent. Although Padina did not prevent adverse effects of ocean acidification, high biomass stands of seagrass or seaweed farms might be more successful in protecting epiphytic foraminifera. PMID:26140195
NASA Astrophysics Data System (ADS)
Thapa, Rajesh
We have made significant accomplishments in the development of portable frequency standard inside hollow optical fibers. Such standards will improve portable optical frequency references available to the telecommunications industry. Our approach relies on the development of a stabilized Cr:forsterite laser to generate the frequency comb in the near-IR region. This laser is self referenced and locked to a CW laser which in turn is stabilized to a sub-Doppler feature of a molecular transition. The molecular transition is realized using a hollow core fiber filled with acetylene gas. We finally measured the absolute frequency of these molecular transitions to characterize the references. In this thesis, the major ideas, techniques and experimental results for the development and absolute frequency measurement of the portable frequency references are presented. A prism-based Cr:forsterite frequency comb is stabilized. We have effectively used the prism modulation along with power modulation inside the cavity in order to actively stabilize the frequency comb. We have also studied the carrier-envelope-offset frequency (f0) dynamics of the laser and its effect on laser stabilization. A reduction of f0 linewidth from ˜2 MHz to ˜20 kHz has also been observed. Both our in-loop and out-of-loop measurements of the comb stability showed that the comb is stable within a part in 1011 at 1-s gate time and is currently limited by our reference signal. In order to develop this portable frequency standard, saturated absorption spectroscopy is performed on the acetylene v1 + v3 band near 1532 nm inside different kinds of hollow optical fibers. The observed linewidths are a factor 2 narrower in the 20 mum fiber as compared to 10 mum fiber, and vary from 20-40 MHz depending on pressure and power. The 70 mum kagome fiber shows a further reduction in linewidth to less than 10 MHz. In order to seal the gas inside the hollow optical fiber, we have also developed a technique of splicing the hollow fiber to solid fiber in a standard commercial arc splicer, rather than the more expensive filament splicer, and achieved comparable splice loss. We locked a CW laser to the saturated absorption feature using a Frequency Modulation technique and then compared to an optical frequency comb. The stabilized frequency comb, providing a dense grid of reference frequencies in near-infrared region is used to characterize and measure the absolute frequency reference based on these hollow optical fibers.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Properties of meso-Erythritol; phase state, accommodation coefficient and saturation vapour pressure
NASA Astrophysics Data System (ADS)
Emanuelsson, Eva; Tschiskale, Morten; Bilde, Merete
2016-04-01
Introduction Saturation vapour pressure and the associated temperature dependence (enthalpy ΔH), are key parameters for improving predictive atmospheric models. Generally, the atmospheric aerosol community lack experimentally determined values of these properties for relevant organic aerosol compounds (Bilde et al., 2015). In this work we have studied the organic aerosol component meso-Erythritol. Methods Sub-micron airborne particles of meso-Erythritol were generated by nebulization from aqueous solution, dried, and a mono disperse fraction of the aerosol was selected using a differential mobility analyser. The particles were then allowed to evaporate in the ARAGORN (AaRhus Atmospheric Gas phase OR Nano particle) flow tube. It is a temperature controlled 3.5 m long stainless steel tube with an internal diameter of 0.026 m (Bilde et al., 2003, Zardini et al., 2010). Changes in particle size as function of evaporation time were determined using a scanning mobility particle sizer system. Physical properties like air flow, temperature, humidity and pressure were controlled and monitored on several places in the setup. The saturation vapour pressures were then inferred from the experimental results in the MATLAB® program AU_VaPCaP (Aarhus University_Vapour Pressure Calculation Program). Results Following evaporation, meso-Erythriol under some conditions showed a bimodal particle size distribution indicating the formation of particles of two different phase states. The issue of physical phase state, along with critical assumptions e.g. the accommodation coefficient in the calculations of saturation vapour pressures of atmospheric relevant compounds, will be discussed. Saturation vapour pressures from the organic compound meso-Erythritol will be presented at temperatures between 278 and 308 K, and results will be discussed in the context of atmospheric chemistry. References Bilde, M. et al., (2015), Chemical Reviews, 115 (10), 4115-4156. Bilde, M. et. al., (2003), Environmental Science and Technology 37(7), 1371-1378. Zardini, A. A. et al., (2010), Journal of Aerosol Science, 41, 760-770.
Zinn, Caryn; Rush, Amy; Johnson, Rebecca
2018-01-01
Objective The low-carbohydrate, high-fat (LCHF) diet is becoming increasingly employed in clinical dietetic practice as a means to manage many health-related conditions. Yet, it continues to remain contentious in nutrition circles due to a belief that the diet is devoid of nutrients and concern around its saturated fat content. This work aimed to assess the micronutrient intake of the LCHF diet under two conditions of saturated fat thresholds. Design In this descriptive study, two LCHF meal plans were designed for two hypothetical cases representing the average Australian male and female weight-stable adult. National documented heights, a body mass index of 22.5 to establish weight and a 1.6 activity factor were used to estimate total energy intake using the Schofield equation. Carbohydrate was limited to <130 g, protein was set at 15%–25% of total energy and fat supplied the remaining calories. One version of the diet aligned with the national saturated fat guideline threshold of <10% of total energy and the other included saturated fat ad libitum. Primary outcomes The primary outcomes included all micronutrients, which were assessed using FoodWorks dietary analysis software against national Australian/New Zealand nutrient reference value (NRV) thresholds. Results All of the meal plans exceeded the minimum NRV thresholds, apart from iron in the female meal plans, which achieved 86%–98% of the threshold. Saturated fat intake was logistically unable to be reduced below the 10% threshold for the male plan but exceeded the threshold by 2 g (0.6%). Conclusion Despite macronutrient proportions not aligning with current national dietary guidelines, a well-planned LCHF meal plan can be considered micronutrient replete. This is an important finding for health professionals, consumers and critics of LCHF nutrition, as it dispels the myth that these diets are suboptimal in their micronutrient supply. As with any diet, for optimal nutrient achievement, meals need to be well formulated. PMID:29439004
Lee, J.Y.; Francisca, F.M.; Santamarina, J.C.; Ruppel, C.
2010-01-01
The small-strain mechanical properties (e.g., seismic velocities) of hydrate-bearing sediments measured under laboratory conditions provide reference values for calibration of logging and seismic exploration results acquired in hydrate-bearing formations. Instrumented cells were designed for measuring the compressional (P) and shear (S) velocities of sand, silts, and clay with and without hydrate and subject to vertical effective stresses of 0.01 to 2 MPa. Tetrahydrofuran (THF), which is fully miscible in water, was used as the hydrate former to permit close control over the hydrate saturation Shyd and to produce hydrate from dissolved phase, as methane hydrate forms in most natural marine settings. The results demonstrate that laboratory hydrate formation technique controls the pattern of P and S velocity changes with increasing Shyd and that the small-strain properties of hydrate-bearing sediments are governed by effective stress, δ'v and sediment specific surface. The S velocity increases with hydrate saturation owing to an increase in skeletal shear stiffness, particularly when hydrate saturation exceeds Shyd≈ 0.4. At very high hydrate saturations, the small strain shear stiffness is determined by the presence of hydrates and becomes insensitive to changes in effective stress. The P velocity increases with hydrate saturation due to the increases in both the shear modulus of the skeleton and the bulk modulus of pore-filling phases during fluid-to-hydrate conversion. Small-strain Poisson's ratio varies from 0.5 in soft sediments lacking hydrates to 0.25 in stiff sediments (i.e., subject to high vertical effective stress or having high Shyd). At Shyd ≥ 0.5, hydrate hinders expansion and the loss of sediment stiffness during reduction of vertical effective stress, meaning that hydrate-rich natural sediments obtained through pressure coring should retain their in situ fabric for some time after core retrieval if the cores are maintained within the hydrate stability field.
Seifi, Sohila; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Najafi, Farid
2018-01-01
Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018-03-19 with reference IRCT20100913004736N22. "Retrospectively registered."
St Leger, A S; Cochrane, A L; Moore, F
1979-05-12
Deaths from ischaemic heart-disease in 18 developed countries are not strongly associated with health-service factors such as doctor and nurse density. There is a negative association with gross national product per capita and a positive but inconsistent association with saturated and monounsaturated fat intake. The principal finding is a strong and specific negative association between ischaemic heart-disease deaths and alcohol consumption. This is shown to be wholly attributable to wine consumption.
2010-02-01
MANUFACTURING DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7750 AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE i REPORT DOCUMENTATION...EPSCoR Instrumentation Award) for support. 6. References [1] Stegeman, G. I . Applications of organic materials in third-order nonlinear optics. In...tetraphenylporphyrins. Opt. Commun. 56, 25. [9] Perry, J. W., Mansour, K., Marder, S. R., Perry, K. J., Alvarez, D, Choong, I . (1994). Enhanced reverse saturable
Saiki, M.; Scoppettone, G.G.; Gadomski, D.; Becker, D.
2005-01-01
When thinking about plants and animals that inhabit hot arid lands of the southwestern U.S., fish are easily overlooked by most people. However, these desert lands often contain isolated springs or cienegas (a Spanish term referring to permanently saturated 'seep wetlands') and streams supporting native fishes that occur no where else in the world. These aquatic remnants from the last Ice Age have survived for thousands of years due to an amazing ability to tolerate harsh environmental conditions, especially extremely high water temperatures, high salinities, and unpredictable water flows.
Reduction in saturated fat intake for cardiovascular disease.
Hooper, Lee; Martin, Nicole; Abdelhamid, Asmaa; Davey Smith, George
2015-06-10
Reducing saturated fat reduces serum cholesterol, but effects on other intermediate outcomes may be less clear. Additionally it is unclear whether the energy from saturated fats that are lost in the diet are more helpfully replaced by polyunsaturated fats, monounsaturated fats, carbohydrate or protein. This review is part of a series split from and updating an overarching review. To assess the effect of reducing saturated fat intake and replacing it with carbohydrate (CHO), polyunsaturated (PUFA) or monounsaturated fat (MUFA) and/or protein on mortality and cardiovascular morbidity, using all available randomised clinical trials. We updated our searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (Ovid) and EMBASE (Ovid) on 5 March 2014. We also checked references of included studies and reviews. Trials fulfilled the following criteria: 1) randomised with appropriate control group; 2) intention to reduce saturated fat intake OR intention to alter dietary fats and achieving a reduction in saturated fat; 3) not multifactorial; 4) adult humans with or without cardiovascular disease (but not acutely ill, pregnant or breastfeeding); 5) intervention at least 24 months; 6) mortality or cardiovascular morbidity data available. Two review authors working independently extracted participant numbers experiencing health outcomes in each arm, and we performed random-effects meta-analyses, meta-regression, subgrouping, sensitivity analyses and funnel plots. We include 15 randomised controlled trials (RCTs) (17 comparisons, ˜59,000 participants), which used a variety of interventions from providing all food to advice on how to reduce saturated fat. The included long-term trials suggested that reducing dietary saturated fat reduced the risk of cardiovascular events by 17% (risk ratio (RR) 0.83; 95% confidence interval (CI) 0.72 to 0.96, 13 comparisons, 53,300 participants of whom 8% had a cardiovascular event, I² 65%, GRADE moderate quality of evidence), but effects on all-cause mortality (RR 0.97; 95% CI 0.90 to 1.05; 12 trials, 55,858 participants) and cardiovascular mortality (RR 0.95; 95% CI 0.80 to 1.12, 12 trials, 53,421 participants) were less clear (both GRADE moderate quality of evidence). There was some evidence that reducing saturated fats reduced the risk of myocardial infarction (fatal and non-fatal, RR 0.90; 95% CI 0.80 to 1.01; 11 trials, 53,167 participants), but evidence for non-fatal myocardial infarction (RR 0.95; 95% CI 0.80 to 1.13; 9 trials, 52,834 participants) was unclear and there were no clear effects on stroke (any stroke, RR 1.00; 95% CI 0.89 to 1.12; 8 trials, 50,952 participants). These relationships did not alter with sensitivity analysis. Subgrouping suggested that the reduction in cardiovascular events was seen in studies that primarily replaced saturated fat calories with polyunsaturated fat, and no effects were seen in studies replacing saturated fat with carbohydrate or protein, but effects in studies replacing with monounsaturated fats were unclear (as we located only one small trial). Subgrouping and meta-regression suggested that the degree of reduction in cardiovascular events was related to the degree of reduction of serum total cholesterol, and there were suggestions of greater protection with greater saturated fat reduction or greater increase in polyunsaturated and monounsaturated fats. There was no evidence of harmful effects of reducing saturated fat intakes on cancer mortality, cancer diagnoses or blood pressure, while there was some evidence of improvements in weight and BMI. The findings of this updated review are suggestive of a small but potentially important reduction in cardiovascular risk on reduction of saturated fat intake. Replacing the energy from saturated fat with polyunsaturated fat appears to be a useful strategy, and replacement with carbohydrate appears less useful, but effects of replacement with monounsaturated fat were unclear due to inclusion of only one small trial. This effect did not appear to alter by study duration, sex or baseline level of cardiovascular risk. Lifestyle advice to all those at risk of cardiovascular disease and to lower risk population groups should continue to include permanent reduction of dietary saturated fat and partial replacement by unsaturated fats. The ideal type of unsaturated fat is unclear.
1,003 reference genomes of bacterial and archaeal isolates expand coverage of the tree of life
Mukherjee, Supratim; Seshadri, Rekha; Varghese, Neha J.; ...
2017-06-12
We present 1,003 reference genomes that were sequenced as part of the Genomic Encyclopedia of Bacteria and Archaea (GEBA) initiative, selected to maximize sequence coverage of phylogenetic space. These genomes double the number of existing type strains and expand their overall phylogenetic diversity by 25%. Comparative analyses with previously available finished and draft genomes reveal a 10.5% increase in novel protein families as a function of phylogenetic diversity. The GEBA genomes recruit 25 million previously unassigned metagenomic proteins from 4,650 samples, improving their phylogenetic and functional interpretation. We identify numerous biosynthetic clusters and experimentally validate a divergent phenazine cluster withmore » potential new chemical structure and antimicrobial activity. This Resource is the largest single release of reference genomes to date. Bacterial and archaeal isolate sequence space is still far from saturated, and future endeavors in this direction will continue to be a valuable resource for scientific discovery.« less
1,003 reference genomes of bacterial and archaeal isolates expand coverage of the tree of life
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, Supratim; Seshadri, Rekha; Varghese, Neha J.
We present 1,003 reference genomes that were sequenced as part of the Genomic Encyclopedia of Bacteria and Archaea (GEBA) initiative, selected to maximize sequence coverage of phylogenetic space. These genomes double the number of existing type strains and expand their overall phylogenetic diversity by 25%. Comparative analyses with previously available finished and draft genomes reveal a 10.5% increase in novel protein families as a function of phylogenetic diversity. The GEBA genomes recruit 25 million previously unassigned metagenomic proteins from 4,650 samples, improving their phylogenetic and functional interpretation. We identify numerous biosynthetic clusters and experimentally validate a divergent phenazine cluster withmore » potential new chemical structure and antimicrobial activity. This Resource is the largest single release of reference genomes to date. Bacterial and archaeal isolate sequence space is still far from saturated, and future endeavors in this direction will continue to be a valuable resource for scientific discovery.« less
Validating a spatially distributed hydrological model with soil morphology data
NASA Astrophysics Data System (ADS)
Doppler, T.; Honti, M.; Zihlmann, U.; Weisskopf, P.; Stamm, C.
2013-10-01
Spatially distributed hydrological models are popular tools in hydrology and they are claimed to be useful to support management decisions. Despite the high spatial resolution of the computed variables, calibration and validation is often carried out only on discharge time-series at specific locations due to the lack of spatially distributed reference data. Because of this restriction, the predictive power of these models, with regard to predicted spatial patterns, can usually not be judged. An example of spatial predictions in hydrology is the prediction of saturated areas in agricultural catchments. These areas can be important source areas for the transport of agrochemicals to the stream. We set up a spatially distributed model to predict saturated areas in a 1.2 km2 catchment in Switzerland with moderate topography. Around 40% of the catchment area are artificially drained. We measured weather data, discharge and groundwater levels in 11 piezometers for 1.5 yr. For broadening the spatially distributed data sets that can be used for model calibration and validation, we translated soil morphological data available from soil maps into an estimate of the duration of soil saturation in the soil horizons. We used redox-morphology signs for these estimates. This resulted in a data set with high spatial coverage on which the model predictions were validated. In general, these saturation estimates corresponded well to the measured groundwater levels. We worked with a model that would be applicable for management decisions because of its fast calculation speed and rather low data requirements. We simultaneously calibrated the model to the groundwater levels in the piezometers and discharge. The model was able to reproduce the general hydrological behavior of the catchment in terms of discharge and absolute groundwater levels. However, the accuracy of the groundwater level predictions was not high enough to be used for the prediction of saturated areas. The groundwater level dynamics were not adequately reproduced and the predicted spatial patterns of soil saturation did not correspond to the patterns estimated from the soil map. Our results indicate that an accurate prediction of the groundwater level dynamics of the shallow groundwater in our catchment that is subject to artificial drainage would require a more complex model. Especially high spatial resolution and very detailed process representations at the boundary between the unsaturated and the saturated zone are expected to be crucial. The data needed for such a detailed model are not generally available. The high computational demand and the complex model setup would require more resources than the direct identification of saturated areas in the field. This severely hampers the practical use of such models despite their usefulness for scientific purposes.
Ferrage, Fabien; Reichel, Amy; Battacharya, Shibani; Cowburn, David; Ghose, Ranajeet
2013-01-01
Measurement of steady-state 15N-{1H} nuclear Overhauser effects forms a cornerstone of most methods to determine protein backbone dynamics from spin-relaxation data, since it is the most reliable probe of very fast motions on the ps-ns timescale. We have, in two previous publications (J. Magn. Reson. 192 (2008), 302-313; J. Am. Chem. Soc. 131 (2009), 6048-6049) reevaluated spin-dynamics during steady-state (or “saturated”) and reference experiments, both of which are required to determine the NOE ratio. Here we assess the performance of several windowed and windowless sequences to achieve effective saturation of protons in steady-state experiments. We also evaluate the influence of the residual water signal due to radiation damping on the NOE ratio. We suggest a recipe that allows one to determine steady-state 15N-{1H} NOE's without artifacts and with the highest possible accuracy. PMID:20951618
Margolis, S A; Levenson, M
2000-05-01
The calibration of Karl Fischer instruments and reagents and the compensation for instrumental bias are essential to the accurate measurement of trace levels of water in organic and inorganic chemicals. A stable, nonhygroscopic standard, Water Saturated Octanol, which is compatible with the Karl Fischer reagents, has been prepared. This material, Standard Reference Material (SRM) 2890, is homogeneous and is certified to contain 39.24 +/- 0.85 mg water/mL (expanded uncertainty) of solution (47.3 +/- 1.0 mg water/g solution, expanded uncertainty) at 21.5 degrees C. The solubility of water in -octanol has been shown to be nearly constant between 10 degrees C and 30 degrees C (i.e., within 1% of the value at 21.5 degrees C). The results of an interlaboratory comparison exercise illustrate the utility of SRM 2890 in assessing the accuracy and bias of Karl Fischer instruments and measurements.
Thermodynamics of reaction of praseodymium with gallium-indium eutectic alloy
NASA Astrophysics Data System (ADS)
Melchakov, S. Yu.; Ivanov, V. A.; Yamshchikov, L. F.; Volkovich, V. A.; Osipenko, A. G.; Kormilitsyn, M. V.
2013-06-01
Thermodynamic properties of Ga-In eutectic alloys saturated with praseodymium were determined for the first time employing the electromotive force method. The equilibrium potentials of the Pr-In alloys saturated with praseodymium (8.7-12.1 mol.% Pr) and Pr-Ga-In alloys (containing 0.0012-6.71 mol.% Pr) were measured between 573-1073 K. Pr-In alloy containing solid PrIn3 with known thermodynamic properties was used as the reference electrode when measuring the potentials of ternary Pr-In-Ga alloys. Activity, partial and excessive thermodynamic functions of praseodymium in alloys with indium and Ga-In eutectic were calculated. Activity (a), activity coefficients (γ) and solubility (X) of praseodymium in the studied temperature range can be expressed by the following equations: lgaα-Pr(In) = 4.425 - 11965/T ± 0.026. lgаα-Pr(Ga-In) = 5.866 - 14766/T ± 0.190. lgγα-Pr(Ga-In) = 2.351 - 9996/T ± 0.39. lgХPr(Ga-In) = 3.515 - 4770/T ± 0.20.
A low-cost, tunable laser lock without laser frequency modulation
NASA Astrophysics Data System (ADS)
Shea, Margaret E.; Baker, Paul M.; Gauthier, Daniel J.
2015-05-01
Many experiments in optical physics require laser frequency stabilization. This can be achieved by locking to an atomic reference using saturated absorption spectroscopy. Often, the laser frequency is modulated and phase sensitive detection used. This method, while well-proven and robust, relies on expensive components, can introduce an undesirable frequency modulation into the laser, and is not easily frequency tuned. Here, we report a simple locking scheme similar to those implemented previously. We modulate the atomic resonances in a saturated absorption setup with an AC magnetic field created by a single solenoid. The same coil applies a DC field that allows tuning of the lock point. We use an auto-balanced detector to make our scheme more robust against laser power fluctuations and stray magnetic fields. The coil, its driver, and the detector are home-built with simple, cheap components. Our technique is low-cost, simple to setup, tunable, introduces no laser frequency modulation, and only requires one laser. We gratefully acknowledge the financial support of the NSF through Grant # PHY-1206040.
The influence of adding fats of varying saturation on the glycaemic response of white bread.
Henry, C Jeya K; Lightowler, Helen J; Newens, Katie J; Pata, Nicki
2008-02-01
The aim of this study was to examine the effect of three different fats of varying degrees of saturation on the glycaemic response of white bread. Standard white bread was served alone or with 30 g butter, 24.8 g olive oil or 24.8 g grape-seed oil. On separate occasions, 15 subjects consumed the four test foods and reference food (glucose) in 50 g available carbohydrate amounts. Capillary blood glucose was measured from finger-prick samples in fasted subjects (-5 and 0 min) and at 15, 30, 45, 60, 90 and 120 min after starting to eat. All fats lowered the glycaemic response of bread; however, no significant differences in glycaemic index were recorded between the types of fat used when ingested with bread. The results of the present study suggest that the glycaemic response of bread can be lowered using any type of fat; therefore, the use of unsaturated fat is recommended for its potential lipidaemic advantage.
Deschamps, Marie-Lys; Sanderson, Penelope; Hinckfuss, Kelly; Browning, Caitlin; Loeb, Robert G; Liley, Helen; Liu, David
2016-09-01
Recent guidelines recommend oxygen saturation (SpO2) levels of 90%-95% for preterm neonates on supplemental oxygen but it is difficult to discern such levels with current pulse oximetry sonifications. We tested (1) whether adding levels of tremolo to a conventional log-linear pulse oximetry sonification would improve identification of SpO2 ranges, and (2) whether adding a beacon reference tone to conventional pulse oximetry confuses listeners about the direction of change. Participants using the Tremolo (94%) or Beacon (81%) sonifications identified SpO2 range significantly more accurately than participants using the LogLinear sonification (52%). The Beacon sonification did not confuse participants about direction of change. The Tremolo sonification may have advantages over the Beacon sonification for monitoring SpO2 of preterm neonates, but both must be further tested with clinicians in clinically representative scenarios, and with different levels of ambient noise and distractions. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Salumbides, E. J.; Eikema, K. S. E.; Ubachs, W.; Hollenstein, U.; Knöckel, H.; Tiemann, E.
2008-04-01
The light from one single frequency cw laser was employed in a double saturation spectroscopy experiment to record high resolution spectra of 129I2 and 127I129I together with spectra of 127I2 which is used as a simultaneous frequency reference. Two separate saturation spectroscopy set ups were used. The frequencies of lines of 129I2 and 127I129I were determined with respect to lines of 127I2. More than 380 frequency differences between lines of 127I2 and of the other isotopomers have been included in the data set. By a direct potential fit a precise description of the potential energy curves of the B and the X state and of effective Born-Oppenheimer correction functions valid for all three isotopomers of I2 are given.
Low frequency ac waveform generator
Bilharz, O.W.
1983-11-22
Low frequency sine, cosine, triangle and square waves are synthesized in circuitry which allows variation in the waveform amplitude and frequency while exhibiting good stability and without requiring significant stablization time. A triangle waveform is formed by a ramped integration process controlled by a saturation amplifier circuit which produces the necessary hysteresis for the triangle waveform. The output of the saturation circuit is tapped to produce the square waveform. The sine waveform is synthesized by taking the absolute value of the triangular waveform, raising this absolute value to a predetermined power, multiplying the raised absolute value of the triangle wave with the triangle wave itself and properly scaling the resultant waveform and subtracting it from the triangular waveform to a predetermined power and adding the squared waveform raised to the predetermined power with a DC reference and subtracting the squared waveform therefrom, with all waveforms properly scaled. The resultant waveform is then multiplied with a square wave in order to correct the polarity and produce the resultant cosine waveform.
Determination of quality factors by microdosimetry
NASA Astrophysics Data System (ADS)
Al-Affan, I. A. M.; Watt, D. E.
1987-03-01
The application of microdose parameters for the specification of a revised scale of quality factors which would be applicable at low doses and dose rates is examined in terms of an original proposal by Rossi. Two important modifications are suggested to enable an absolute scale of quality factors to be constructed. Allowance should be made to allow for the dependence of the saturation threshold of lineal energy on the type of heavy charged particle. Also, an artificial saturation threshold should be introduced for electron tracks as a mean of modifying the measurements made in the microdosimeter to the more realistic site sizes of nanometer dimensions. The proposed absolute scale of quality factors nicely encompasses the high RBEs of around 3 observed at low doses for tritium β rays and is consistent with the recent recommendation of the ICRP that the quality factor for fast neutrons be increased by a factor of two, assuming that there is no biological repair for the reference radiation.
Coupled Heat and Moisture Transport Simulation on the Re-saturation of Engineered Clay Barrier
NASA Astrophysics Data System (ADS)
Huang, W. H.; Chuang, Y. F.
2014-12-01
Engineered clay barrier plays a major role for the isolation of radioactive wastes in a underground repository. This paper investigates the resaturation processes of clay barrier, with emphasis on the coupling effects of heat and moisture during the intrusion of groundwater to the repository. A reference bentonite and a locally available clay were adopted in the laboratory program. Soil suction of clay specimens was measured by psychrometers embedded in clay specimens and by vapor equilibrium technique conducted at varying temperatures so as to determine the soil water characteristic curves of the two clays at different temperatures. And water uptake tests were conducted on clay specimens compacted at various densities to simulate the intrusion of groundwater into the clay barrier. Using the soil water characteristic curve, an integration scheme was introduced to estimate the hydraulic conductivity of unsaturated clay. It was found that soil suction decreases as temperature increases, resulting in a reduction in water retention capability. The finite element method was then employed to carry out the numerical simulation of the saturation process in the near field of a repository. Results of the numerical simulation were validated using the degree of saturation profile obtained from the water uptake tests on the clays. The numerical scheme was then extended to establish a model simulating the resaturation process after the closure of a repository. Finally, the model was then used to evaluate the effect of clay barrier thickness on the time required for groundwater to penetrate the clay barrier and approach saturation. Due to the variation in clay suction and thermal conductivity with temperature of clay barrier material, the calculated temperature field shows a reduction as a result of incorporating the hydro-properties in the calculations.
Quantification of in vivo pH-weighted amide proton transfer (APT) MRI in acute ischemic stroke
NASA Astrophysics Data System (ADS)
Zhou, Iris Y.; Igarashi, Takahiro; Guo, Yingkun; Sun, Phillip Z.
2015-03-01
Amide proton transfer (APT) imaging is a specific form of chemical exchange saturation transfer (CEST) MRI that probes the pH-dependent amide proton exchange.The endogenous APT MRI is sensitive to tissue acidosis, which may complement the commonly used perfusion and diffusion scans for characterizing heterogeneous ischemic tissue damage. Whereas the saturation transfer asymmetry analysis (MTRasym) may reasonably compensate for direct RF saturation, in vivo MTRasym is however, susceptible to an intrinsically asymmetric shift (MTR'asym). Specifically, the reference scan for the endogenous APT MRI is 7 ppm upfield from that of the label scan, and subjects to concomitant RF irradiation effects, including nuclear overhauser effect (NOE)-mediated saturation transfer and semisolid macromolecular magnetization transfer. As such, the commonly used asymmetry analysis could not fully compensate for such slightly asymmetric concomitant RF irradiation effects, and MTRasym has to be delineated in order to properly characterize the pH-weighted APT MRI contrast. Given that there is very little change in relaxation time immediately after ischemia and the concomitant RF irradiation effects only minimally depends on pH, the APT contrast can be obtained as the difference of MTRasym between the normal and ischemic regions. Thereby, the endogenous amide proton concentration and exchange rate can be solved using a dual 2-pool model, and the in vivo MTR'asym can be calculated by subtracting the solved APT contrast from asymmetry analysis (i.e., MTR'asym =MTRasym-APTR). In addition, MTR'asym can be quantified using the classical 2-pool exchange model. In sum, our study delineated the conventional in vivo pH-sensitive MTRasym contrast so that pHspecific contrast can be obtained for imaging ischemic tissue acidosis.
NASA Technical Reports Server (NTRS)
Seifina, Elena; Titarchuk, Lev; Shaposhnikov, Nikolai
2014-01-01
We present the results of a comprehensive investigation on the evolution of spectral and timing properties of the Galactic black hole candidate 4U 1630-47 during its spectral transitions. In particular, we show how a scaling of the correlation of the photon index of the Comptonized spectral component gamma with low-frequency quasi-periodic oscillations (QPOs), ?(sub L), and mass accretion rate, M, can be applied to the black hole mass and the inclination angle estimates.We analyze the transition episodes observed with the Rossi X-Ray Timing Explorer and BeppoSAX satellites.We find that the broadband X-ray energy spectra of 4U 1630-47 during all spectral states can be modeled by a combination of a thermal component, a Comptonized component, and a red-skewed iron-line component. We also establish that gamma monotonically increases during transition from the low-hard state to the high-soft state and then saturates for high mass accretion rates. The index saturation levels vary for different transition episodes. Correlations of gamma versus ?(sub L) also show saturation at gamma (is) approximately 3. Gamma -M and gamma -?(sub L) correlations with their index saturation revealed in 4U 1630-47 are similar to those established in a number of other black hole candidates and can be considered as an observational evidence for the presence of a black hole in these sources. The scaling technique, which relies on XTE J1550-564, GRO 1655-40, and H1743-322 as reference sources, allows us to evaluate a black hole mass in 4U 1630-47 yielding M(sub BH) (is) approximately 10 +/- 0.1 solar masses and to constrain the inclination angle of i (is) approximately less than 70 deg.
Modeling variably saturated subsurface solute transport with MODFLOW-UZF and MT3DMS
Morway, Eric D.; Niswonger, Richard G.; Langevin, Christian D.; Bailey, Ryan T.; Healy, Richard W.
2013-01-01
The MT3DMS groundwater solute transport model was modified to simulate solute transport in the unsaturated zone by incorporating the unsaturated-zone flow (UZF1) package developed for MODFLOW. The modified MT3DMS code uses a volume-averaged approach in which Lagrangian-based UZF1 fluid fluxes and storage changes are mapped onto a fixed grid. Referred to as UZF-MT3DMS, the linked model was tested against published benchmarks solved analytically as well as against other published codes, most frequently the U.S. Geological Survey's Variably-Saturated Two-Dimensional Flow and Transport Model. Results from a suite of test cases demonstrate that the modified code accurately simulates solute advection, dispersion, and reaction in the unsaturated zone. Two- and three-dimensional simulations also were investigated to ensure unsaturated-saturated zone interaction was simulated correctly. Because the UZF1 solution is analytical, large-scale flow and transport investigations can be performed free from the computational and data burdens required by numerical solutions to Richards' equation. Results demonstrate that significant simulation runtime savings can be achieved with UZF-MT3DMS, an important development when hundreds or thousands of model runs are required during parameter estimation and uncertainty analysis. Three-dimensional variably saturated flow and transport simulations revealed UZF-MT3DMS to have runtimes that are less than one tenth of the time required by models that rely on Richards' equation. Given its accuracy and efficiency, and the wide-spread use of both MODFLOW and MT3DMS, the added capability of unsaturated-zone transport in this familiar modeling framework stands to benefit a broad user-ship.
Modeling variably saturated subsurface solute transport with MODFLOW-UZF and MT3DMS.
Morway, Eric D; Niswonger, Richard G; Langevin, Christian D; Bailey, Ryan T; Healy, Richard W
2013-03-01
The MT3DMS groundwater solute transport model was modified to simulate solute transport in the unsaturated zone by incorporating the unsaturated-zone flow (UZF1) package developed for MODFLOW. The modified MT3DMS code uses a volume-averaged approach in which Lagrangian-based UZF1 fluid fluxes and storage changes are mapped onto a fixed grid. Referred to as UZF-MT3DMS, the linked model was tested against published benchmarks solved analytically as well as against other published codes, most frequently the U.S. Geological Survey's Variably-Saturated Two-Dimensional Flow and Transport Model. Results from a suite of test cases demonstrate that the modified code accurately simulates solute advection, dispersion, and reaction in the unsaturated zone. Two- and three-dimensional simulations also were investigated to ensure unsaturated-saturated zone interaction was simulated correctly. Because the UZF1 solution is analytical, large-scale flow and transport investigations can be performed free from the computational and data burdens required by numerical solutions to Richards' equation. Results demonstrate that significant simulation runtime savings can be achieved with UZF-MT3DMS, an important development when hundreds or thousands of model runs are required during parameter estimation and uncertainty analysis. Three-dimensional variably saturated flow and transport simulations revealed UZF-MT3DMS to have runtimes that are less than one tenth of the time required by models that rely on Richards' equation. Given its accuracy and efficiency, and the wide-spread use of both MODFLOW and MT3DMS, the added capability of unsaturated-zone transport in this familiar modeling framework stands to benefit a broad user-ship. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Zheng, F.; Shi, X.; Wu, J.; Gao, Y. W.
2013-12-01
Chlorinated solvents such as trichloroethene (TCE) and tetrachloroethene (PCE) are widespread groundwater contaminants often referred to as dense non-aqueous phase liquids (DNAPLs). Accuracy description of the spreading behavior and configuration for subsurface DNAPL migration is important, especially favourable for design effective remediation strategies. In this study, a 2-D experiment was conducted to investigate the infiltration behavior and spatial distribution of PCE in saturated porous media. Accusand 20/30 mesh sand (Unimin, Le Sueur, MN) was used as the background medium with two 70/80 and 60/70 mesh lenses embedded to simulate heterogeneous conditions. Dyed PCE of 100 ml was released into the flow cell at a constant rate of 2ml/min using a Harvard Apparatus syringe pump with a 50 ml glass syringe for two times, and 5 ml/min water was continuously injected through the inlet at the left side of the sandbox, while kept the same effluent rate at right side to create hydrodynamic condition. A light transmission (LT) system was used to record the migration of PCE and determine the saturation distribution of PCE in the sandbox experiment with a thermoelectrically air-cooled charged-coupled device (CCD) camera. All images were processed using MATLAB to calculate thickness-averaged PCE saturation for each pixel. Mass balance was checked through comparing injected known mounts of PCE with that calculated from LT analysis. Results showed that LT method is effective to delineate PCE migration pathways and quantify the saturation distribution. The relative errors of total PCE volumes calculated by LT analysis at different times were within 15% of the injected PCE volumes. The simulation are conducted using the multiphase modeling software T2VOC, which calibrated by the LT analysis results of three recorded time steps to fit with the complete spatial-temporal distribution of the PCE saturation. Model verification was then performed using the other eight recorded time steps. Simulated results showed that the model could successfully reproduce the migration pathways and distribution configuration observed from the laboratory experiment and LT analysis, excepted for a smaller pool height on the lenses, and a lower saturation values in PCE accumulation area due to local heterogeneities. Due to the influence of water flow, the PCE distribution was asymmetrical, and the PCE distribution area, pool height as well as PCE saturation in the accumulation region at right side was much greater. Acknowledge: This work is financially supported by the National Nature Science Foundation of China grants No. 41030746 and 41172206.
NASA Astrophysics Data System (ADS)
Eguchi, James; Dasgupta, Rajdeep
2017-03-01
We have performed experiments to determine the effects of pressure, temperature and oxygen fugacity on the CO2 contents in nominally anhydrous andesitic melts at graphite saturation. The andesite composition was specifically chosen to match a low-degree partial melt composition that is generated from MORB-like eclogite in the convective, oceanic upper mantle. Experiments were performed at 1-3 GPa, 1375-1550 °C, and fO2 of FMQ -3.2 to FMQ -2.3 and the resulting experimental glasses were analyzed for CO2 and H2O contents using FTIR and SIMS. Experimental results were used to develop a thermodynamic model to predict CO2 content of nominally anhydrous andesitic melts at graphite saturation. Fitting of experimental data returned thermodynamic parameters for dissolution of CO2 as molecular CO2: ln( K 0) = -21.79 ± 0.04, Δ V 0 = 32.91 ± 0.65 cm3mol-1, Δ H 0 = 107 ± 21 kJ mol-1, and dissolution of CO2 as CO3 2-: ln (K 0 ) = -21.38 ± 0.08, Δ V 0 = 30.66 ± 1.33 cm3 mol-1, Δ H 0 = 42 ± 37 kJ mol-1, where K 0 is the equilibrium constant at some reference pressure and temperature, Δ V 0 is the volume change of reaction, and Δ H 0 is the enthalpy change of reaction. The thermodynamic model was used along with trace element partition coefficients to calculate the CO2 contents and CO2/Nb ratios resulting from the mixing of a depleted MORB and the partial melt of a graphite-saturated eclogite. Comparison with natural MORB and OIB data suggests that the CO2 contents and CO2/Nb ratios of CO2-enriched oceanic basalts cannot be produced by mixing with partial melts of graphite-saturated eclogite. Instead, they must be produced by melting of a source containing carbonate. This result places a lower bound on the oxygen fugacity for the source region of these CO2-enriched basalts, and suggests that fO2 measurements made on cratonic xenoliths may not be applicable to the convecting upper mantle. CO2-depleted basalts, on the other hand, are consistent with mixing between depleted MORB and partial melts of a graphite-saturated eclogite. Furthermore, calculations suggest that eclogite can remain saturated in graphite in the convecting upper mantle, acting as a reservoir for C.
NASA Astrophysics Data System (ADS)
Afshari, Ali; Ghassemi, Pejhman; Halprin, Molly; Lin, Jonathan; Weininger, Sandy; Gandjbakhche, Amir H.; Wang, Jianting; Pfefer, Joshua
2018-02-01
Clinical cerebral oximeters based on near-infrared spectroscopy (NIRS) are a commonly used, non-invasive tool for intraoperative monitoring of hemoglobin saturation. Research to verify performance of cerebral oximeters in human subject trials has shown differences between commercially available devices. Test methods based on tissue-simulating phantoms have been proposed to augment clinical findings. While prior studies have focused on liquid phantoms, this work is aimed at developing methods based on solid polymer phantoms that are stable. Specifically, we have designed and fabricated a neonatal/pediatric head mimicking layered phantoms based on a 3D-printed cerebral matrix incorporating an array of vessel-simulating linear channels. Superficial layers incorporating homogeneous molded polydimethylsiloxane (PDMS) slabs were fabricated to represent CSF, scalp and skull regions. The cerebral matrix was filled with bovine blood desaturated with sodium dithionite to achieve oxygenation levels across the 40-90% range. Measurements were performed with a commercially available cerebral oximeter using two probes with different illumination-collection geometries, as designed for neonatal and pediatric patients. Reference measurements of samples were performed with a CO-oximeter before injection and after extraction. Results from applied cerebral oximeters indicate a strong sensitivity to the thickness of the superficial layer of the phantom. Better correlation with the reference CO-oximeter results were obtained in the superficial layer thickness of 0.8-2.5 mm range. Channel array phantoms with modular superficial layers represent a promising approach for performance testing of NIRS-based cerebral oximeters.
Moos, M T; Taffs, K H; Longstaff, B J; Ginn, B K
2014-08-01
Innovative management strategies for nutrient enrichment of freshwater are important in the face of this increasing global problem, however many strategies are not assessed over long enough time periods to establish effectiveness. Paleolimnological techniques using diatoms as biological indicators were utilized to establish ecological reference conditions, environmental variation, and the effectiveness of lanthanum-saturated bentonite clay (brand name: Phoslock(®)) applied to reduce water column phosphorus (P) concentrations in four waterbodies in Ontario, Canada, and eastern Australia. In sediment cores from the two Canadian sites, there were short-lived changes to diatom assemblages, relative to inferred background conditions, and a temporary reduction in both measured and diatom-inferred total phosphorus (TP) before returning to pre-application conditions (particularly in the urban stormwater management pond which has a high flushing rate and responds rapidly to precipitation and surface run-off). The two Australian sites (a sewage treatment pond and a shallow recreational lake), recorded no reduction in diatom-inferred TP. Based on our pre-application environmental reconstruction, changes to the diatom assemblages and diatom-inferred TP appeared to be driven by larger, climatic factors. While laboratory tests involving this product showed sharp reductions in water column TP, management strategies require detailed information on pre-application environmental conditions and variations in order to accurately assess the effectiveness of new technologies for lake management. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ferroresonant flux coupled battery charger
NASA Technical Reports Server (NTRS)
McLyman, Colonel W. T. (Inventor)
1987-01-01
A battery charger for incorporation into an electric-powered vehicle is disclosed. The charger includes a ferroresonant voltage-regulating circuit for providing an output voltage proportional to the frequency of an input AC voltage. A high frequency converter converts a DC voltage supplied, for example, from a rectifier connected to a standard AC outlet, to a controlled frequency AC voltage which is supplied to the input of the ferroresonant circuit. The ferroresonant circuit includes an output, a saturable core transformer connected across the output, and a first linear inductor and a capacitor connected in series across the saturable core transformer and tuned to resonate at the third harmonic of the AC voltage from the high frequency converter. The ferroresonant circuit further includes a second linear inductor connected between the input of the ferroresonant circuit and the saturable core transformer. The output voltage from the ferroresonant circuit is rectified and applied across a pair of output terminals adapted to be connected to the battery to be charged. A feedback circuit compares the voltage across the output terminals with a reference voltage and controls the frequency of the AC voltage produced by the high frequency converter to maintain the voltage across the output terminals at a predetermined value. The second linear inductor provides a highly reactive load in the event of a fault across the output terminals to render the charger short-circuit proof.
Drag Coefficient and Foam in Hurricane Conditions.
NASA Astrophysics Data System (ADS)
Golbraikh, E.; Shtemler, Y.
2016-12-01
he present study is motivated by recent findings of saturation and even decrease in the drag coefficient (capping) in hurricane conditions, which is accompanied by the production of a foam layer on the ocean surface. As it is difficult to expect at present a comprehensive numerical modeling of the drag coefficient saturation that is followed by wave breaking and foam production, there is no complete confidence and understanding of the saturation phenomenon. Our semi-empirical model is proposed for the estimation of the foam impact on the variation of the effective drag coefficient, Cd , with the reference wind speed U10 in stormy and hurricane conditions. The proposed model treats the efficient air-sea aerodynamic roughness length as a sum of two weighted aerodynamic roughness lengths for the foam-free and foam-covered conditions. On the available optical and radiometric measurements of the fractional foam coverage,αf, combined with direct wind speed measurements in hurricane conditions, which provide the minimum of the effective drag coefficient, Cd for the sea covered with foam. The present model yields Cd10 versus U10 in fair agreement with that evaluated from both open-ocean and laboratory measurements of the vertical variation of mean wind speed in the range of U10 from low to hurricane speeds. The present approach opens opportunities for drag coefficient modeling in hurricane conditions and hurricane intensity estimation by the foam-coverage value using optical and radiometric measurements.
Saturated Widths of Magnetic Islands in Tokamak Discharges
NASA Astrophysics Data System (ADS)
Halpern, F.; Pankin, A. Y.
2005-10-01
The new ISLAND module described in reference [1] implements a quasi-linear model to compute the widths of multiple magnetic islands driven by saturated tearing modes in toroidal plasmas of arbitrary aspect ratio and cross sectional shape. The distortion of the island shape caused by the radial variation in the perturbation is computed in the new module. In transport simulations, the enhanced transport caused by the magnetic islands has the effect of flattening the pressure and current density profiles. This self consistent treatment of the magnetic islands alters the development of the plasma profiles. In addition, it is found that islands closer to the magnetic axis influence the evolution of islands further out in the plasma. In order to investigate such phenomena, the ISLAND module is used within the BALDUR predictive modeling code to compute the widths of multiple magnetic islands in tokamak discharges. The interaction between the islands and sawtooth crashes is examined in simulations of DIII-D and JET discharges. The module is used to compute saturated neoclassical tearing mode island widths for multiple modes in ITER. Preliminary results for island widths in ITER are consistent with those presented [2] by Hegna. [1] F.D. Halpern, G. Bateman, A.H. Kritz and A.Y. Pankin, ``The ISLAND Module for Computing Magnetic Island Widths in Tokamaks,'' submitted to J. Plasma Physics (2005). [2] C.C. Hegna, 2002 Fusion Snowmass Meeting.
Burivalova, Zuzana; Towsey, Michael; Boucher, Tim; Truskinger, Anthony; Apelis, Cosmas; Roe, Paul; Game, Edward T
2018-02-01
There is global concern about tropical forest degradation, in part, because of the associated loss of biodiversity. Communities and indigenous people play a fundamental role in tropical forest management and are often efficient at preventing forest degradation. However, monitoring changes in biodiversity due to degradation, especially at a scale appropriate to local tropical forest management, is plagued by difficulties, including the need for expert training, inconsistencies across observers, and lack of baseline or reference data. We used a new biodiversity remote-sensing technology, the recording of soundscapes, to test whether the acoustic saturation of a tropical forest in Papua New Guinea decreases as land-use intensity by the communities that manage the forest increases. We sampled soundscapes continuously for 24 hours at 34 sites in different land-use zones of 3 communities. Land-use zones where forest cover was fully retained had significantly higher soundscape saturation during peak acoustic activity times (i.e., dawn and dusk chorus) compared with land-use types with fragmented forest cover. We conclude that, in Papua New Guinea, the relatively simple measure of soundscape saturation may provide a cheap, objective, reproducible, and effective tool for monitoring tropical forest deviation from an intact state, particularly if it is used to detect the presence of intact dawn and dusk choruses. © 2017 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.
Rejection of Erroneous Saturation Data in Optical Pulse Oximetry in Newborn Patients
NASA Astrophysics Data System (ADS)
Scalise, L.; Marchionni, Paolo; Carnielli, Virgilio P.
2011-08-01
Pulse oximetry (PO) is extensively used in intensive care unit (ICU); this is mainly due to the fact that it is a non-invasive and real-time monitoring method. PO allows to measure arterial oxygen saturation (SaO2) and in particular hemoglobin oxygenation. Optical PO is typically realized by the use of a clip (to be applied on the ear or on the finger top) containing a couple of monochromatic LED sources and a photodiode. The main drawback with the use of PO is the presence of movement artifacts or disturbance due to optical sources and skin, causing erroneous saturation data. The aim of this work is to present the measurement procedure based on a specially developed algorithm able to reject erroneous oxygen saturation data during long lasting monitoring of patients in ICU and to compare measurement data with reference data provided by EGA. We have collected SaO2 data from a standard PO and used an intensive care unit monitor to collect data. This device was connected to our acquisition system and heart rate (HR) and SaO2 data were acquired and processed by our specially developed algorithm and directly reproduced on the PC screen for use by the clinicians. The algorithm here used for the individuation and rejection of erroneous saturation data is based on the assessment of the difference between the Heart Rate (HR) measured by respectively by the ECG and PO. We have used an emogasanalyzer (EGA) for comparison of the measured data. The study was carried out in a neonatal intensive care unit (NICU), using 817 data coming from 24 patients and the observation time was of about 10000 hours. Results show a reduction in the maximum difference between the SaO2 data measured, simultaneously, on the same patient by the EGA and by the proposed method of 14.20% and of the 4.76% in average over the 817 samples. The measurement method proposed is therefore able to individuate and eliminate the erroneous saturation data due to motion artifacts and reported by the pulse oxymeter. Specifically in neonatal ICU, it allows to come to more efficient individuation of apnea, hypoxia and hyperoxia events and consequently to operate more adequate and efficient therapeutic actions.
Sacristan, C J; Dupont, T; Sicot, O; Leclaire, P; Verdière, K; Panneton, R; Gong, X L
2016-10-01
The acoustic properties of an air-saturated macroscopically inhomogeneous aluminum foam in the equivalent fluid approximation are studied. A reference sample built by forcing a highly compressible melamine foam with conical shape inside a constant diameter rigid tube is studied first. In this process, a radial compression varying with depth is applied. With the help of an assumption on the compressed pore geometry, properties of the reference sample can be modelled everywhere in the thickness and it is possible to use the classical transfer matrix method as theoretical reference. In the mixture approach, the material is viewed as a mixture of two known materials placed in a patchwork configuration and with proportions of each varying with depth. The properties are derived from the use of a mixing law. For the reference sample, the classical transfer matrix method is used to validate the experimental results. These results are used to validate the mixture approach. The mixture approach is then used to characterize a porous aluminium for which only the properties of the external faces are known. A porosity profile is needed and is obtained from the simulated annealing optimization process.
Multiple-wavelength spectroscopic quantitation of light-absorbing species in scattering media
Nathel, Howard; Cartland, Harry E.; Colston, Jr., Billy W.; Everett, Matthew J.; Roe, Jeffery N.
2000-01-01
An oxygen concentration measurement system for blood hemoglobin comprises a multiple-wavelength low-coherence optical light source that is coupled by single mode fibers through a splitter and combiner and focused on both a target tissue sample and a reference mirror. Reflections from both the reference mirror and from the depths of the target tissue sample are carried back and mixed to produce interference fringes in the splitter and combiner. The reference mirror is set such that the distance traversed in the reference path is the same as the distance traversed into and back from the target tissue sample at some depth in the sample that will provide light attenuation information that is dependent on the oxygen in blood hemoglobin in the target tissue sample. Two wavelengths of light are used to obtain concentrations. The method can be used to measure total hemoglobin concentration [Hb.sub.deoxy +Hb.sub.oxy ] or total blood volume in tissue and in conjunction with oxygen saturation measurements from pulse oximetry can be used to absolutely quantify oxyhemoglobin [HbO.sub.2 ] in tissue. The apparatus and method provide a general means for absolute quantitation of an absorber dispersed in a highly scattering medium.
Yu, Hui; Wan, Hui; Feng, Chunhua; Yi, Xiaoyun; Liu, Xiaoping; Ren, Yuan; Wei, Chaohai
2017-02-15
The necessity for developing an efficient and cost-effective in situ bioremediation technology for sediments contaminated with polychlorinated biphenyls (PCBs) has prompted the application of low-voltage electrical fields to anaerobic digestion systems. Here we show that the use of a sediment-based bio-electrochemical reactor (BER) poised at a potential of -0.50V (vs. a standard calomel electrode, SCE) substantially enhanced the reduction of 2,3,4,5-tetrachlorobiphenyl (PCB 61) when acetate was added as a carbon source. The addition of surfactant Tween 80 to the BER further accelerated the PCB 61 transformation. The comparative study of closed- and open-circuit reactors demonstrated the enrichment conditions affecting the bacterial community structure, the dominant dechlorination metabolisms, and thus the extent, the rate and the products of the reduction of PCBs. The dominant bacterial dechlorinators detected in the BERs in the presence of acetate and Tween 80 are Dehalogenimonas, Dehalobacter, Sulfuricurvum, Dechloromonas and Geobacter, which should be responsible for PCB dechlorination. This study improves understanding of the key factors influencing dechlorination activity in sediment-based BERs polarized at a low potential, as well as the metabolic mechanisms dominating in the PCB dechlorination process. Copyright © 2016 Elsevier B.V. All rights reserved.
Rowley-Neale, Samuel J; Smith, Graham C; Banks, Craig E
2017-07-12
Two-dimensional molybdenum disulfide (2D-MoS 2 ) screen-printed electrodes (2D-MoS 2 -SPEs) have been designed, fabricated, and evaluated toward the electrochemical oxygen reduction reaction (ORR) within acidic aqueous media. A screen-printable ink has been developed that allows for the tailoring of the 2D-MoS 2 content/mass used in the fabrication of the 2D-MoS 2 -SPEs, which critically affects the observed ORR performance. In comparison to the graphite SPEs (G-SPEs), the 2D-MoS 2 -SPEs are shown to exhibit an electrocatalytic behavior toward the ORR which is found, critically, to be reliant upon the percentage mass incorporation of 2D-MoS 2 in the 2D-MoS 2 -SPEs; a greater percentage mass of 2D-MoS 2 incorporated into the 2D-MoS 2 -SPEs results in a significantly less electronegative ORR onset potential and a greater signal output (current density). Using optimally fabricated 2D-MoS 2 -SPEs, an ORR onset and a peak current of approximately +0.16 V [vs saturated calomel electrode (SCE)] and -1.62 mA cm -2 , respectively, are observed, which exceeds the -0.53 V (vs SCE) and -635 μA cm -2 performance of unmodified G-SPEs, indicating an electrocatalytic response toward the ORR utilizing the 2D-MoS 2 -SPEs. An investigation of the underlying electrochemical reaction mechanism of the ORR within acidic aqueous solutions reveals that the reaction proceeds via a direct four-electron process for all of the 2D-MoS 2 -SPE variants studied herein, where oxygen is electrochemically favorably reduced to water. The fabricated 2D-MoS 2 -SPEs are found to exhibit no degradation in the observed achievable current over the course of 1000 repeat scans. The production of such inks and the resultant mass-producible 2D-MoS 2 -SPEs mitigates the need to modify post hoc an electrode via the drop-casting technique that has been previously shown to result in a loss of achievable current over the course of 1000 repeat scans. The 2D-MoS 2 -SPEs designed, fabricated, and tested herein could have commercial viability as electrocatalytic fuel cell electrodes because of being economical as a result of their scales of economy and inherent tailorability. The technique utilized herein to produce the 2D-MoS 2 -SPEs could be adapted for the incorporation of different 2D nanomaterials, resulting in SPEs with the inherent advantages identified above.
Preliminary flight prototype silver ion monitoring system
NASA Technical Reports Server (NTRS)
Brady, J.
1974-01-01
The design, fabrication, and testing of a preliminary flight prototype silver ion monitoring system based on potentiometric principles and utilizing a solid-state silver sulfide electrode paired with a pressurized double-junction reference electrode housing a replaceable electrolyte reservoir is described. The design provides automatic electronic calibration utilizing saturated silver bromide solution as a silver ion standard. The problem of loss of silver ion from recirculating fluid, its cause, and corrective procedures are reported. The instability of the silver sulfide electrode is discussed as well as difficulties met in implementing the autocalibration procedure.
Relative validation of Block Kids Food Screener for dietary assessment in children and adolescents.
Hunsberger, Monica; O'Malley, Jean; Block, Torin; Norris, Jean C
2015-04-01
Food frequency questionnaires (FFQs) are less time consuming and inexpensive instruments for collecting dietary intake when compared with 24-h dietary recalls or double-labelled water; however, the validation of FFQ is important as incorrect information may lead to biased conclusions about associations. Therefore, the relative validity of the Block Kids Food Screener (BKFS) developed for use with children was examined in a convenience sample of 99 youth recruited from the Portland, OR metropolitan area. Three 24-h dietary recalls served as the reference. The relative validity was analysed after natural log transformation of all variables except glycaemic index prior to correlation analysis. Daily cup equivalent totals from the BKFS and 'servings' from 24-h recalls were used to compute average daily intake of fruits, vegetables, potatoes, whole grains, legumes, meat/fish/poultry and dairy. Protein grams (g), total kcalories, glycaemic index (glucose reference), glycaemic load (glucose reference), total saturated fat (g) and added sugar (g) were also calculated by each instrument. The correlation between data obtained from the two instruments was corrected for the within-subject variation in food intake reported by the 24-h recalls using standard nutritional assessment methodology. The de-attenuated correlations in nutritional intake between the two dietary assessment instruments ranged from 0.526 for vegetables, to 0.878 for potatoes. The 24-h recall estimated higher levels of saturated fat and added sugar consumption, higher glycaemic loads and glycaemic indices; the de-attenuatted correlations of these measures ranged from 0.478 to 0.768. Assessment of Bland-Altman plots indicated no systematic difference between the two instruments for vegetable, dairy and meat/fish/poultry fat consumption. BKFS is a useful dietary assessment instrument for the nutrients and food groups it was designed to assess in children age 10-17 years. © 2012 Blackwell Publishing Ltd.
Oxygen saturation in healthy children aged 5 to 16 years residing in Huayllay, Peru at 4340 m.
Schult, Sandra; Canelo-Aybar, Carlos
2011-01-01
Hypoxemia is a major life-threatening complication of childhood pneumonia. The threshold points for hypoxemia vary with altitude. However, few published data describe that normal range of variation. The purpose of this study was to establish reference values of normal mean Sao(2) levels and an approximate cutoff point to define hypoxemia for clinical purposes above 4300 meters above sea level (masl). Children aged 5 to 16 yr were examined during primary care visits at the Huayllay Health Center. Huayllay is a rural community located at 4340 m in the province of Pasco in the Peruvian Andes. We collected basic sociodemographic data and evaluated three outcomes: arterial oxygen saturation (Sao(2)) with a pulse oximeter, heart rate, and respiratory rate. Comparisons of main outcomes among age groups (5-6, 7-8, 9-10, 11-12, 13-14, and 15-16 yr) and sex were performed using linear regression models. The correlation of Sao(2) with heart rate and respiration rate was established by Pearson's correlation test. We evaluated 583 children, of whom 386 were included in the study. The average age was 10.3 yr; 55.7% were female. The average Sao(2), heart rate, and respiratory rate were 85.7% (95% CI: 85.2-86.2), 80.4/min (95% CI: 79.0-81.9), and 19.9/min (95% CI: 19.6-20.2), respectively. Sao(2) increased with age (p < 0.001). No differences by sex were observed. The mean minus two standard deviations of Sao(2) (threshold point for hypoxemia) ranged from 73.8% to 81.8% by age group. At 4300 m, the reference values for hypoxemia may be 14.2% lower than at sea level. This difference must be considered when diagnosing hypoxemia or deciding oxygen supplementation at high altitude. Other studies are needed to determine whether this reference value is appropriate for clinical use.
Venn-Watson, Stephanie K.; Parry, Celeste; Baird, Mark; Stevenson, Sacha; Carlin, Kevin; Daniels, Risa; Smith, Cynthia R.; Jones, Richard; Wells, Randall S.; Ridgway, Sam; Jensen, Eric D.
2015-01-01
Similar to humans, bottlenose dolphins (Tursiops truncatus) can develop metabolic syndrome and associated high ferritin. While fish and fish-based fatty acids may protect against metabolic syndrome in humans, findings have been inconsistent. To assess potential protective factors against metabolic syndrome related to fish diets, fatty acids were compared between two dolphin populations with higher (n = 30, Group A) and lower (n = 19, Group B) mean insulin (11 ± 12 and 2 ± 5 μIU/ml, respectively; P < 0.0001) and their dietary fish. In addition to higher insulin, triglycerides, and ferritin, Group A had lower percent serum heptadecanoic acid (C17:0) compared to Group B (0.3 ± 0.1 and 1.3 ± 0.4%, respectively; P < 0.0001). Using multivariate stepwise regression, higher percent serum C17:0, a saturated fat found in dairy fat, rye, and some fish, was an independent predictor of lower insulin in dolphins. Capelin, a common dietary fish for Group A, had no detectable C17:0, while pinfish and mullet, common in Group B’s diet, had C17:0 (41 and 67 mg/100g, respectively). When a modified diet adding 25% pinfish and/or mullet was fed to six Group A dolphins over 24 weeks (increasing the average daily dietary C17:0 intake from 400 to 1700 mg), C17:0 serum levels increased, high ferritin decreased, and blood-based metabolic syndrome indices normalized toward reference levels. These effects were not found in four reference dolphins. Further, higher total serum C17:0 was an independent and linear predictor of lower ferritin in dolphins in Group B dolphins. Among off the shelf dairy products tested, butter had the highest C17:0 (423mg/100g); nonfat dairy products had no detectable C17:0. We hypothesize that humans’ movement away from diets with potentially beneficial saturated fatty acid C17:0, including whole fat dairy products, could be a contributor to widespread low C17:0 levels, higher ferritin, and metabolic syndrome. PMID:26200116
Lu, Ying-Chun; Wang, Chih-Chien; Lee, Chuen-Ming; Hwang, Kwei-Shuai; Hua, Yi-Ming; Yuh, Yeong-Seng; Chiu, Yu-Lung; Hsu, Wan-Fu; Chou, Ya-Ling; Huang, Shao-Wei; Lee, Yih-Jing; Fan, Hueng-Chuen
2014-12-01
We compared our clinical experience with currently available reference oxygen saturation level (SpO(2)) values from the American Academy of Pediatrics/American Heart Association (AAP/AHA) neonatal resuscitation program guidelines. We enrolled 145 healthy full-term neonates; infants showing respiratory distress and those with serious congenital anomalies were excluded. SpO(2) values at every 1 minute until 10 minutes after birth were measured and recorded. Infants were classified into the cesarean section (CS) and normal spontaneous delivery (NSD) groups for evaluating differences. The 10(th) percentiles of SpO(2) at each minute were used as the lower limits of normal oxygen saturation, and these were compared with the lowest target values recommended in the AAP/AHA guidelines. Overall, 130 vigorous full-term neonates (median gestational age: 38 5/7 weeks; body weight at birth: 2405-3960 g) were analyzed. The median SpO(2) were 67% and 89% at the 1(st) and 4(th) minute, respectively. On average, SpO(2) values reached >90% at the 5(th) minute. No statistical differences were noted in the SpO(2) values between the CS and NSD groups after 5 minutes; however, a trend of higher SpO(2) was observed in the NSD group. We noted a gradually increasing trend for SpO(2) values over time, similar to that noted in the AAP/AHA guidelines. However, SpO(2) values at the 10(th) percentiles of each minute within the first 5 minutes in our study were equal to or significantly lower than those in the AAP/AHA guidelines; moreover, at the 10(th) minute, SpO(2) values at the 10(th) percentiles were significantly higher than those in the guidelines. The delivery modes did not affect the SpO(2) values of full-term healthy neonates. Discrepancies in SpO(2) changes in full-term neonates not requiring resuscitation between this study and the AAP/AHA guidelines were significant. SpO(2) ranges for each time point within the first 10 minutes after birth should therefore be reevaluated locally. Copyright © 2014. Published by Elsevier B.V.
Novel laboratory methods for determining the fine scale electrical resistivity structure of core
NASA Astrophysics Data System (ADS)
Haslam, E. P.; Gunn, D. A.; Jackson, P. D.; Lovell, M. A.; Aydin, A.; Prance, R. J.; Watson, P.
2014-12-01
High-resolution electrical resistivity measurements are made on saturated rocks using novel laboratory instrumentation and multiple electrical voltage measurements involving in principle a four-point electrode measurement but with a single, moving electrode. Flat, rectangular core samples are scanned by varying the electrode position over a range of hundreds of millimetres with an accuracy of a tenth of a millimetre. Two approaches are tested involving a contact electrode and a non-contact electrode arrangement. The first galvanic method uses balanced cycle switching of a floating direct current (DC) source to minimise charge polarisation effects masking the resistivity distribution related to fine scale structure. These contacting electrode measurements are made with high common mode noise rejection via differential amplification with respect to a reference point within the current flow path. A computer based multifunction data acquisition system logs the current through the sample and voltages along equipotentials from which the resistivity measurements are derived. Multiple measurements are combined to create images of the surface resistivity structure, with variable spatial resolution controlled by the electrode spacing. Fine scale sedimentary features and open fractures in saturated rocks are interpreted from the measurements with reference to established relationships between electrical resistivity and porosity. Our results successfully characterise grainfall lamination and sandflow cross-stratification in a brine saturated, dune bedded core sample representative of a southern North Sea reservoir sandstone, studied using the system in constant current, variable voltage mode. In contrast, in a low porosity marble, identification of open fracture porosity against a background very low matrix porosity is achieved using the constant voltage, variable current mode. This new system is limited by the diameter of the electrode that for practical reasons can only be reduced to between 0.5 and 0.75 mm. Improvements to this resolution may be achieved by further reducing the electrode footprint to 0.1 mm × 0.1 mm using a novel high-impedance, non-contact potential probe. Initial results with this non-contact electric potential sensor indicate the possibility for generating images with grain-scale resolution.
Maalouf, Joyce; Cogswell, Mary E; Bates, Marlana; Yuan, Keming; Scanlon, Kelley S; Pehrsson, Pamela; Gunn, Janelle P; Merritt, Robert K
2017-06-01
Background: As part of a healthy diet, limiting intakes of excess sodium, added sugars, saturated fat, and trans fat has been recommended. The American Heart Association recommends that children aged <2 y should avoid added sugars. Objective: We sought to determine commercial complementary infant-toddler food categories that were of potential concern because of the sodium, added sugar, saturated fat, or trans fat content. Design: Nutrition label information (e.g., serving size, sodium, saturated fat, trans fat) for 1032 infant and toddler foods was collected from manufacturers' websites and stores from May to July 2015 for 24 brands, which accounted for >95% of infant-toddler food sales. The presence of added sugars was determined from the ingredient list. Reference amount customarily consumed (RACC) categories were used to group foods and standardize serving sizes. A high sodium content was evaluated on the basis of the Upper Intake Level for children aged 1-3 y and the number of potential servings per day ([i.e., 1500 mg/7 servings (>210 mg/RACC)], a sodium amount >200 mg/100 g, or a mean sodium density >1000 mg/1000 kcal. Results: In 2015, most commercial infant-only vegetables, fruit, dinners, and cereals were low in sodium, contained no saturated fat, and did not contain added sugars. On average, toddler meals contained 2233 mg Na/1000 kcal, and 84% of the meals had >210 mg Na/RACC (170 g), whereas 69% of infant-toddler savory snacks had >200 mg Na/100 g. More than 70% of toddler meals, cereal bars and breakfast pastries, and infant-toddler grain- or dairy-based desserts contained ≥1 sources of added sugar. Approximately 70% of toddler meals contained saturated fat (mean: 1.9 g/RACC), and no commercial infant-toddler foods contained trans fats. Conclusion: Most commercial toddler meals, cereal bars and breakfast pastries, and infant-toddler snacks and desserts have high sodium contents or contain added sugars, suggesting a need for continued public health efforts to support parents in choosing complementary foods for their infants and toddlers. © 2017 American Society for Nutrition.
Fidler Mis, Nataša; Kobe, Helena; Stimec, Matevž
2012-01-01
Data on a nationally representative dietary intake in Central Europe is lacking. We investigated the diet of adolescents in Slovenia. Dietary habits were assessed using a food frequency questionnaire (n = 2,661), and present nutrition was assessed using a 3-day weighted dietary protocol (n = 197) for validation purposes. Dietary intake was calculated and compared with Central European [German (D), Austrian (A), and Swiss (CH); D-A-CH] recommendations and World Health Organization/Food and Agriculture Organization (WHO/FAO) recommendations. Adolescents consumed exceeding reference intake values of free sugars (boys 16% of energy, girls 17%), saturated fatty acids (SFA; 13% of energy), and sodium (boys 203%, girls 210% of the WHO/FAO upper limit), but below-reference intake values of polyunsaturated fatty acids (PUFA; boys 5% of energy; girls 6%), water (boys 1,786 ml/day, girls 2,016 ml/day), and fiber density (only girls 2.8 g/MJ, p < 0.001). Among micronutrients, below-reference intakes (% of D-A-CH: boys and girls, respectively, p < 0.05) were reported for folate (64 and 69%), fluoride (28 and 31%), and calcium (91 and 97%), as well as for vitamin D (20 and 20%). The dietary habits of Slovenian adolescents are less than optimal. They are characterized by exceeding reference intake values of free sugars, salt, and SFA, and a below-reference intake of PUFA, water, and several micronutrients. Copyright © 2012 S. Karger AG, Basel.
Evaluating Daily Load Stimulus Formulas in Relating Bone Response to Exercise
NASA Technical Reports Server (NTRS)
Pennline, James A.; Mulugeta, Lealem
2014-01-01
Six formulas representing what is commonly referred to as "daily load stimulus" are identified, compared and tested in their ability to relate skeletal mechanical loading to bone maintenance and osteogenic response. Particular emphasis is placed on exercise- induced skeletal loading and whether or not the formulas can adequately capture the known experimental observations of saturation of continuous cyclic loading, rest insertion between repetitions (cycles), recovery of osteogenic potential following saturation, and multiple shorter bouts versus a single long bout of exercise. To evaluate the ability of the formulas to capture these characteristics, a set of exercise scenarios with type of exercise bout, specific duration, number of repetitions, and rest insertion between repetitions is defined. The daily load values obtained from the formulas for the loading conditions of the set of scenarios is illustrated. Not all of the formulas form estimates of daily load in units of stress or in terms of strain at a skeletal site due to the loading force from a specific exercise prescription. The comparative results show that none of the formulas are able to capture all of the experimentally observed characteristics of cyclic loading. However, the enhanced formula presented by Genc et al. does capture several characteristics of cyclic loading that the others do not, namely recovery of osteogenic potential and saturation. This could be a basis for further development of mathematical formulas that more adequately approximates the amount of daily stress at a skeletal site that contributes to bone adaptation.
Hwang, In Cheol; Ahn, Hong Yup; Park, Sang Min; Shim, Jae Yong; Kim, Kyoung Kon
2013-03-01
There is scant research concerning the prediction of imminent death, and current studies simply list events "that have already occurred" around 48 h of the death. We sought to determine what events herald the onset of dying process using the length of time from "any change" to death. This is a prospective observational study with chart audit. Inclusion criteria were terminal cancer patients who passed away in a palliative care unit. The analysis was limited to 181 patients who had medical records for their final week. Commonly observed events in the terminally ill were determined and their significant changes were defined beforehand. We selected the statistically significant changes by multiple logistic regression analysis and evaluated their predictive values for "death within 48 h." The median age was 67 years and there were 103 male patients. After adjusting for age, sex, primary cancer site, metastatic site, and cancer treatment, multiple logistic regression analyses for association between the events and "death within 48 h" revealed some significant changes: confused mental state, decreased blood pressure, increased pulse pressure, low oxygen saturation, death rattle, and decreased conscious level. The events that had higher predictability for death within 48 h were decreased blood pressure and low oxygen saturation, and the positive and negative predictive values of their combination were 95.0 and 81.4%, respectively. The most reliable events to predict impending death were decreased blood pressure and low oxygen saturation.
Slow light in saturable absorbers: Progress in the resolution of a controversy
NASA Astrophysics Data System (ADS)
Macke, Bruno; Razdobreev, Igor; Ségard, Bernard
2017-06-01
There are two opposing models in the analysis of the slow transmission of light pulses through saturable absorbers. The canonical incoherent bleaching model simply explains the slow transmission by combined effects of saturation and of noninstantaneous response of the medium resulting in absorption of the front part of the incident pulse larger than that of its rear. The second model, referred to as the coherent-population-oscillations (CPO) model, considers light beams whose intensity is slightly pulse modulated and attributes the time delay of the transmitted pulse to a reduction of the group velocity. We point out some inconsistencies in the CPO model and show that the two models lie in reality on the same hypotheses, the equations derived in the duly rectified CPO model being local expressions of the integral equations obtained in the incoherent bleaching model. When intense pulses without background are used, the CPO model, based on linearized equations, breaks down. The incoherent bleaching model then predicts that the transmitted light should vanish when the intensity of the incident light is strictly zero. This point is confirmed by the experiments that we have performed on ruby with square-wave incident pulses and we show that the whole shape of the observed pulses agrees with that derived analytically by means of the incoherent bleaching model. We also determine in this model the corresponding evolution of the fluorescence light, which seems to have been evidenced in other experiments.
NASA Astrophysics Data System (ADS)
Sarac, Abdulhamit; Kysar, Jeffrey W.
2018-02-01
We present a new methodology for experimental validation of single crystal plasticity constitutive relationships based upon spatially resolved measurements of the direction of the Net Burgers Density Vector, which we refer to as the β-field. The β-variable contains information about the active slip systems as well as the ratios of the Geometrically Necessary Dislocation (GND) densities on the active slip systems. We demonstrate the methodology by comparing single crystal plasticity finite element simulations of plane strain wedge indentations into face-centered cubic nickel to detailed experimental measurements of the β-field. We employ the classical Peirce-Asaro-Needleman (PAN) hardening model in this study due to the straightforward physical interpretation of its constitutive parameters that include latent hardening ratio, initial hardening modulus and the saturation stress. The saturation stress and the initial hardening modulus have relatively large influence on the β-variable compared to the latent hardening ratio. A change in the initial hardening modulus leads to a shift in the boundaries of plastic slip sectors with the plastically deforming region. As the saturation strength varies, both the magnitude of the β-variable and the boundaries of the plastic slip sectors change. We thus demonstrate that the β-variable is sensitive to changes in the constitutive parameters making the variable suitable for validation purposes. We identify a set of constitutive parameters that are consistent with the β-field obtained from the experiment.
Robles, Victor Muñoz; Dürrenberger, Marc; Heinisch, Tillmann; Lledós, Agustí; Schirmer, Tilman; Ward, Thomas R; Maréchal, Jean-Didier
2014-11-05
An artificial imine reductase results upon incorporation of a biotinylated Cp*Ir moiety (Cp* = C5Me5(-)) within homotetrameric streptavidin (Sav) (referred to as Cp*Ir(Biot-p-L)Cl] ⊂ Sav). Mutation of S112 reveals a marked effect of the Ir/streptavidin ratio on both the saturation kinetics as well as the enantioselectivity for the production of salsolidine. For [Cp*Ir(Biot-p-L)Cl] ⊂ S112A Sav, both the reaction rate and the selectivity (up to 96% ee (R)-salsolidine, kcat 14-4 min(-1) vs [Ir], KM 65-370 mM) decrease upon fully saturating all biotin binding sites (the ee varying between 96% ee and 45% ee R). In contrast, for [Cp*Ir(Biot-p-L)Cl] ⊂ S112K Sav, both the rate and the selectivity remain nearly constant upon varying the Ir/streptavidin ratio [up to 78% ee (S)-salsolidine, kcat 2.6 min(-1), KM 95 mM]. X-ray analysis complemented with docking studies highlight a marked preference of the S112A and S112K Sav mutants for the SIr and RIr enantiomeric forms of the cofactor, respectively. Combining both docking and saturation kinetic studies led to the formulation of an enantioselection mechanism relying on an "induced lock-and-key" hypothesis: the host protein dictates the configuration of the biotinylated Ir-cofactor which, in turn, by and large determines the enantioselectivity of the imine reductase.
How shear increments affect the flow production branching ratio in CSDX
NASA Astrophysics Data System (ADS)
Li, J. C.; Diamond, P. H.
2018-06-01
The coupling of turbulence-driven azimuthal and axial flows in a linear device absent magnetic shear (Controlled Shear Decorrelation Experiment) is investigated. In particular, we examine the apportionment of Reynolds power between azimuthal and axial flows, and how the azimuthal flow shear affects axial flow generation and saturation by drift wave turbulence. We study the response of the energy branching ratio, i.e., ratio of axial and azimuthal Reynolds powers, PzR/PyR , to incremental changes of azimuthal and axial flow shears. We show that increasing azimuthal flow shear decreases the energy branching ratio. When axial flow shear increases, this ratio first increases but then decreases to zero. The axial flow shear saturates below the threshold for parallel shear flow instability. The effects of azimuthal flow shear on the generation and saturation of intrinsic axial flows are analyzed. Azimuthal flow shear slows down the modulational growth of the seed axial flow shear, and thus reduces intrinsic axial flow production. Azimuthal flow shear reduces both the residual Reynolds stress (of axial flow, i.e., ΠxzR e s ) and turbulent viscosity ( χzDW ) by the same factor |⟨vy⟩'|-2Δx-2Ln-2ρs2cs2 , where Δx is the distance relative to the reference point where ⟨vy⟩=0 in the plasma frame. Therefore, the stationary state axial flow shear is not affected by azimuthal flow shear to leading order since ⟨vz⟩'˜ΠxzR e s/χzDW .
Zhang, Shuangyou; Wu, Jiutao; Leng, Jianxiao; Lai, Shunnan; Zhao, Jianye
2014-11-15
In this Letter, we demonstrate a fully stabilized Er:fiber frequency comb by using a fiber-based, high-precision optical-microwave phase detector. To achieve high-precision and long-term phase locking of the repetition rate to a microwave reference, frequency control techniques (tuning pump power and cavity length) are combined together as its feedback. Since the pump power has been used for stabilization of the repetition rate, we introduce a pair of intracavity prisms as a regulator for carrier-envelope offset frequency, thereby phase locking one mode of the comb to the rubidium saturated absorption transition line. The stabilized comb performs the same high stability as the reference for the repetition rate and provides a residual frequency instability of 3.6×10(-13) for each comb mode. The demonstrated stabilization scheme could provide a high-precision comb for optical communication, direct frequency comb spectroscopy.
Mixed Convection Opposing Flow in a Vertical Porous Annulus-Two Temperature Model
NASA Astrophysics Data System (ADS)
Al-Rashed, Abdullah A. AA; J, Salman Ahmed N.; Khaleed, H. M. T.; Yunus Khan, T. M.; NazimAhamed, K. S.
2016-09-01
The opposing flow in a porous medium refers to a condition when the forcing velocity flows in opposite direction to thermal buoyancy obstructing the buoyant force. The present research refers to the effect of opposing flow in a vertical porous annulus embedded with fluid saturated porous medium. The thermal non-equilibrium approach with Darcy modal is considered. The boundary conditions are such that the inner radius is heated with constant temperature Tw the outer radius is maintained at constant temperature Tc. The coupled nonlinear partial differential equations such as momentum equation, energy equation for fluid and energy equation for solid are solved using the finite element method. The opposing flow variation of average Nusselt number with respect to radius ratio Rr, Aspect ratioAr and Radiation parameter Rd for different values of Peclet number Pe are investigated. It is found that the flow behavior is quite different from that of aiding flow.
NASA Astrophysics Data System (ADS)
Clemens, J. D.; Stevens, G.
2015-10-01
In this invited 'review' article, the authors come to the conclusion that fluid-present partial melting reactions are of widespread occurrence and critical importance in the processes of high-grade metamorphism and crustal differentiation. In their abstract, the authors correctly restate the conclusions of Clemens and Droop (1998) that it is not necessarily the case that melts formed by fluid-present reactions (even by H2O-saturated melting) cannot leave their sources. This realisation is not actually relevant to the question of formation and ascent of granitic magmas by crustal partial melting. Although they refer to Clemens and Watkins (2001), the authors seem ignore the main point of the argument presented therein, namely that the distribution of temperature and H2O contents in felsic igneous systems is only compatible with derivation of the magmas by fluid-absent partial melting reactions at high-temperature, granulite-facies conditions. Neither fluid-saturated nor fluid-deficient partial melting could have resulted in the observed covariation in temperature and melt H2O content.
Stability Analysis of an Encapsulated Microbubble against Gas Diffusion
Katiyar, Amit; Sarkar, Kausik
2009-01-01
Linear stability analysis is performed for a mathematical model of diffusion of gases from an encapsulated microbubble. It is an Epstein-Plesset model modified to account for encapsulation elasticity and finite gas permeability. Although, bubbles, containing gases other than air is considered, the final stable bubble, if any, contains only air, and stability is achieved only when the surrounding medium is saturated or oversaturated with air. In absence of encapsulation elasticity, only a neutral stability is achieved for zero surface tension, the other solution being unstable. For an elastic encapsulation, different equilibrium solutions are obtained depending on the saturation level and whether the surface tension is smaller or higher than the elasticity. For an elastic encapsulation, elasticity can stabilize the bubble. However, imposing a non-negativity condition on the effective surface tension (consisting of reference surface tension and the elastic stress) leads to an equilibrium radius which is only neutrally stable. If the encapsulation can support net compressive stress, it achieves actual stability. The linear stability results are consistent with our recent numerical findings. Physical mechanisms for the stability or instability of various equilibriums are provided. PMID:20005522
NASA Astrophysics Data System (ADS)
Brestkin, A. P.; Vikhreva, L. A.; Godovikov, Nikolai N.; Zhukovskii, Yu G.; Kabachnik, Martin I.; Moralev, S. N.; Rosengart, V. I.; Sherstobitov, O. E.
1991-08-01
Data are given in the review on the anticholinesterase activity of 58 specially synthesised esters of phosphorus thioacids containing an acetylenic bond in the thioester group. It was established that compounds containing an acetylenic group in the β and especially in the α position of the thioester residue display an inhibitory action many times greater than that of their saturated analogues. A phosphorylated enzyme is formed by the reaction of the acetylenic organophosphorus inhibitors (OPIs) with the enzymes as in the case of reaction with the saturated analogues. It was shown that the acetylenic organophosphorus inhibitors possess high biological activity both for mammals and for arthropods. On replacing the phosphoryl oxygen (P=O) by sulphur (P=S) the toxicity of the acetylenic organophosphorus inhibitors for mammals was sharply reduced but was little changed for arthropods. This raises the possibility of obtaining highly selective insecto-acaricides. The mechanism of the antienzymic action of the acetylenic OPIs and the mechanism of detoxication of diethyl S-hexynyl dithiophosphate are considered. The bibliography includes 44 references.
Low frequency AC waveform generator
Bilharz, Oscar W.
1986-01-01
Low frequency sine, cosine, triangle and square waves are synthesized in circuitry which allows variation in the waveform amplitude and frequency while exhibiting good stability and without requiring significant stabilization time. A triangle waveform is formed by a ramped integration process controlled by a saturation amplifier circuit which produces the necessary hysteresis for the triangle waveform. The output of the saturation circuit is tapped to produce the square waveform. The sine waveform is synthesized by taking the absolute value of the triangular waveform, raising this absolute value to a predetermined power, multiplying the raised absolute value of the triangle wave with the triangle wave itself and properly scaling the resultant waveform and subtracting it from the triangular waveform itself. The cosine is synthesized by squaring the triangular waveform, raising the triangular waveform to a predetermined power and adding the squared waveform raised to the predetermined power with a DC reference and subtracting the squared waveform therefrom, with all waveforms properly scaled. The resultant waveform is then multiplied with a square wave in order to correct the polarity and produce the resultant cosine waveform.
Nonlinearity Analysis for Efficient Modelling of Long-Term CO2 Storage
NASA Astrophysics Data System (ADS)
Li, Boxiao; Benson, Sally; Tchelepi, Hamdi
2014-05-01
Numerical simulation is widely used to predict the long-term fate of the injected CO2 in a storage formation. Performing large-scale simulations is often limited by the computational speed, where convergence failure of Newton iterations is one of the main bottlenecks. In order to design better numerical schemes and faster nonlinear solvers for modelling long-term CO2 storage, the nonlinearity in the simulations has to be analysed thoroughly, and the cause of convergence failures has to be identified clearly. We focus on the transport of CO2 and water in the presence of viscous, gravity, and heterogeneous capillary forces. We investigate the nonlinearity of the discrete transport equation obtained from finite-volume discretization with single-point phase-based upstream weighting, which is the industry standard. In particular, we study the discretized flux expressed as a function of saturations at the upstream and downstream (with respect to the total velocity) of each gridblock interface. We analyse the locations and complexity of the unit-flux, zero-flux, and inflection lines on the numerical flux. The unit- and zero-flux lines, referred to as kinks, correspond to a change of the flow direction, which often occurs when strong buoyancy and capillarity are present. We observe that these kinks and inflection lines are major sources of nonlinear convergence difficulties. We find that kinks create more challenges than inflection lines, especially when their locations depend on both the upstream and downstream saturations of the total velocity. When the flow is driven by viscous and gravity forces (e.g., during CO2 injection), one kink will occur in the numerical flux and its location depends only on the upstream saturation. However, when capillarity is dominant (e.g., during the post-injection period), two kinks will occur and both are functions of the upstream and downstream saturations, causing severe convergence difficulties particularly when heterogeneity is present. Our analysis of the numerical flux theoretically describes the cause of the convergence failures for simulating long-term CO2 storage. This understanding provides useful guidance in designing numerical schemes and nonlinear solvers that overcome the convergence bottlenecks. For example, to reduce the nonlinearity introduced by the two kinks in the presence of capillarity, we modify the method of Cances (2009) to discretize the capillary flux. Consequently, only one kink will occur even for coupled viscous, buoyancy, and heterogeneous capillary forces, and the kink depends only on the upstream saturation of the total velocity. An efficient nonlinear solver that is a significant refinement of the works of Jenny et al. (2009) and Wang and Tchelepi (2013) has also been proposed and demonstrated. References [1] C. Cances. Finite volume scheme for two-phase flows in heterogeneous porous media involving capillary pressure discontinuities. ESAIM:M2AN., 43, 973-1001, (2009). [2] P. Jenny, H.A. Tchelepi, and S.H. Lee. Unconditionally convergent nonlinear solver for hyperbolic conservation laws with S-shaped flux functions. J. Comput. Phys., 228, 7497-7512, (2009). [3] X. Wang and H.A. Tchelepi. Trust-region based solver for nonlinear transport in heterogeneous porous media. J. Comput. Phys., 253, 114-137, (2013).
Code Saturation Versus Meaning Saturation: How Many Interviews Are Enough?
Hennink, Monique M; Kaiser, Bonnie N; Marconi, Vincent C
2017-03-01
Saturation is a core guiding principle to determine sample sizes in qualitative research, yet little methodological research exists on parameters that influence saturation. Our study compared two approaches to assessing saturation: code saturation and meaning saturation. We examined sample sizes needed to reach saturation in each approach, what saturation meant, and how to assess saturation. Examining 25 in-depth interviews, we found that code saturation was reached at nine interviews, whereby the range of thematic issues was identified. However, 16 to 24 interviews were needed to reach meaning saturation where we developed a richly textured understanding of issues. Thus, code saturation may indicate when researchers have "heard it all," but meaning saturation is needed to "understand it all." We used our results to develop parameters that influence saturation, which may be used to estimate sample sizes for qualitative research proposals or to document in publications the grounds on which saturation was achieved.
Crock, J.G.; Severson, R.C.
1980-01-01
Attaining acceptable precision in extractable element determinations is more difficult than in total element determinations. In total element determinations, dissolution of the sample is qualitatively checked by the clarity of the solution and the absence of residues. These criteria cannot be used for extracts. Possibilities for error are introduced in virtually every step in soil extractions. Therefore, the use of reference materials whose homogeneity and element content are reasonably well known is essential for determination of extractable elements. In this report, estimates of homogeneity and element content are presented for four reference samples. Bulk samples of about 100 kilograms of each sample were ground to pass an 80-mesh sieve. The samples were homogenized and split using a Jones-type splitter. Fourteen splits of each reference sample were analyzed for total content of Ca, Co, Cu, Fe, K, Mg, Mn, Na, and Zn; DTPA-extractable Cd, Co, Cu, Fe, Mn, Ni, Pb, and Zn; exchangeable Ca, Mg, K, and Na; cation exchange capacity water-saturation-extractable Ca, Mg, K, Na, C1, and SO4; soil pH; and hot-water-extractable boron. Error measured between splits was small, indicating that the samples were homogenized adequately and that the laboratory procedure provided reproducible results.
Time-efficient high-resolution whole-brain three-dimensional macromolecular proton fraction mapping
Yarnykh, Vasily L.
2015-01-01
Purpose Macromolecular proton fraction (MPF) mapping is a quantitative MRI method that reconstructs parametric maps of a relative amount of macromolecular protons causing the magnetization transfer (MT) effect and provides a biomarker of myelination in neural tissues. This study aimed to develop a high-resolution whole-brain MPF mapping technique utilizing a minimal possible number of source images for scan time reduction. Methods The described technique is based on replacement of an actually acquired reference image without MT saturation by a synthetic one reconstructed from R1 and proton density maps, thus requiring only three source images. This approach enabled whole-brain three-dimensional MPF mapping with isotropic 1.25×1.25×1.25 mm3 voxel size and scan time of 20 minutes. The synthetic reference method was validated against standard MPF mapping with acquired reference images based on data from 8 healthy subjects. Results Mean MPF values in segmented white and gray matter appeared in close agreement with no significant bias and small within-subject coefficients of variation (<2%). High-resolution MPF maps demonstrated sharp white-gray matter contrast and clear visualization of anatomical details including gray matter structures with high iron content. Conclusions Synthetic reference method improves resolution of MPF mapping and combines accurate MPF measurements with unique neuroanatomical contrast features. PMID:26102097
Poulsen, Kjeld; Cleal, Bryan; Willaing, Ingrid
2014-12-01
To investigate the extent and socioeconomic distribution of incident diabetes among the Danish working-age population. The Danish National Diabetes Register was linked with socioeconomic and population-based registers covering the entire population. We analysed the 12-year diabetes incidence using multivariate Poisson regression for 2,086,682 people, adjusting for gender, 10-year age groups, main population groups defined by country of origin, and seven socioeconomic groups: professionals, managers, technicians, workers skilled at basic level, unskilled workers, unemployed and pensioners. The crude 12-year incidence of diabetes was 5.8%. The saturated multivariate model, adjusted for gender, age, country of origin and socioeconomic status; showed a relative risk (RR) for diabetes incidence of 1.44 for male (reference: female), 3.95 for the age range of 50-59 years (reference: 30-39 years), 2.07 for unskilled workers (reference: professionals) and 2.15 for people from countries of 'non-Western origin' (reference: Danish origin). Diabetes incidence increases with age, male gender and low socioeconomic status; and also among people from countries of 'non-Western origin'. The results indicate that getting a more senior workforce will substantially increase the proportion of workers with diabetes, especially among already vulnerable groups. © 2014 the Nordic Societies of Public Health.
An automated protocol for performance benchmarking a widefield fluorescence microscope.
Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T
2014-11-01
Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.
Taccola, Camille; Cartot-Cotton, Sylvaine; Valente, Delphine; Barneoud, Pascal; Aubert, Catherine; Boutet, Valérie; Gallen, Fabienne; Lochus, Murielle; Nicolic, Sophie; Dodacki, Agnès; Smirnova, Maria; Cisternino, Salvatore; Declèves, Xavier; Bourasset, Fanchon
2018-05-30
Efficacy of drugs aimed at treating central nervous system (CNS) disorders rely partly on their ability to cross the cerebral endothelium, also called the blood-brain barrier (BBB), which constitutes the main interface modulating exchanges of compounds between the brain and blood. In this work, we used both, conventional pharmacokinetics (PK) approach and in situ brain perfusion technique to study the blood and brain PK of PKRinh, an inhibitor of the double-stranded RNA-dependent protein kinase (PKR) activation, in mice. PKRinh showed a supra dose-proportional blood exposure that was not observed in the brain, and a brain to blood AUC ratio of unbound drug smaller than 1 at all tested doses. These data suggested the implication of an active efflux at the BBB. Using in situ brain perfusion technique, we showed that PKRinh has a very high brain uptake clearance which saturates with increasing concentrations. Fitting the data to a Michaelis-Menten equation revealed that PKRinh transport through the BBB is composed of a passive unsaturable flux and an active saturable protein-mediated efflux with a k m of ≅ 3 μM. We were able to show that the ATP-binding cassette (ABC) transporter P-gp (Abcb1), but not Bcrp (Abcg2), was involved in the brain to blood efflux of PKRinh. At the circulating PKRinh concentrations of this study, the P-gp was not saturated, in accordance with the linear brain PKRinh PK. Finally, PKRinh had high brain uptake clearance (14 μl/g/s) despite it is a good P-gp substrate (P-gp Efflux ratio ≅ 3.6), and reached similar values than the cerebral blood flow reference, diazepam, in P-gp saturation conditions. With its very unique brain transport properties, PKRinh improves our knowledge about P-gp-mediated efflux across the BBB for the development of new CNS directed drugs. Copyright © 2018. Published by Elsevier B.V.
Hazarika, Ankita; Kalita, Himadri; Kalita, Mohan Chandra; Devi, Rajlakshmi
2017-06-01
The "lipid hypothesis" determined that saturated fatty acid (SFA) raises low-density lipoprotein cholesterol, thereby increasing the risk for metabolic syndrome (MetS). The aim of this study was to investigate the effect of subchronic withdrawal from a high-carbohydrate, high-saturated fat (HCHF) diet during MetS with reference to changes in deleterious SFA (C12:0, lauric acid; C14:0, myristic acid; C16:0, palmitic acid; C18:0, stearic acid) distribution in liver, white adipose tissue (WAT), and feces. MetS induced by prolonged feeding of an HCHF diet in Wistar albino rat is used as a model of human MetS. The MetS-induced rats were withdrawn from the HCHF diet and changed to a basal diet for final 4 wk of the total experimental duration of 16 wk. SFA distribution in target tissues and hepatic low-density lipoprotein receptor (LDLr) expression were analyzed. Analyses of changes in SFA concentration of target tissues indicate that C16:0 and C18:0 reduced in WAT and liver after withdrawal of the HCHF diet. There was a significant (P < 0.001) decrease in fecal C12:0 with HCHF feeding, which significantly (P < 0.01) increased after withdrawal of this diet. Also, an improvement in expression of hepatic LDLr was observed after withdrawal of HCHF diet. The prolonged consumption of an HCHF diet leads to increased SFA accumulation in liver and WAT, decreased SFA excretion, and reduced hepatic LDLr expression during MetS, which is prominently reversed after subchronic withdrawal of the HCHF diet. This can contribute to better understanding of the metabolic fate of dietary SFA during MetS and may apply to the potential reversal of complications by the simple approach of nutritional modification. Copyright © 2017 Elsevier Inc. All rights reserved.
2013-01-01
Background Rapid development of highly saturated genetic maps aids molecular breeding, which can accelerate gain per breeding cycle in woody perennial plants such as Rubus idaeus (red raspberry). Recently, robust genotyping methods based on high-throughput sequencing were developed, which provide high marker density, but result in some genotype errors and a large number of missing genotype values. Imputation can reduce the number of missing values and can correct genotyping errors, but current methods of imputation require a reference genome and thus are not an option for most species. Results Genotyping by Sequencing (GBS) was used to produce highly saturated maps for a R. idaeus pseudo-testcross progeny. While low coverage and high variance in sequencing resulted in a large number of missing values for some individuals, a novel method of imputation based on maximum likelihood marker ordering from initial marker segregation overcame the challenge of missing values, and made map construction computationally tractable. The two resulting parental maps contained 4521 and 2391 molecular markers spanning 462.7 and 376.6 cM respectively over seven linkage groups. Detection of precise genomic regions with segregation distortion was possible because of map saturation. Microsatellites (SSRs) linked these results to published maps for cross-validation and map comparison. Conclusions GBS together with genome-independent imputation provides a rapid method for genetic map construction in any pseudo-testcross progeny. Our method of imputation estimates the correct genotype call of missing values and corrects genotyping errors that lead to inflated map size and reduced precision in marker placement. Comparison of SSRs to published R. idaeus maps showed that the linkage maps constructed with GBS and our method of imputation were robust, and marker positioning reliable. The high marker density allowed identification of genomic regions with segregation distortion in R. idaeus, which may help to identify deleterious alleles that are the basis of inbreeding depression in the species. PMID:23324311
Infiltration and runoff generation processes in fire-affected soils
Moody, John A.; Ebel, Brian A.
2014-01-01
Post-wildfire runoff was investigated by combining field measurements and modelling of infiltration into fire-affected soils to predict time-to-start of runoff and peak runoff rate at the plot scale (1 m2). Time series of soil-water content, rainfall and runoff were measured on a hillslope burned by the 2010 Fourmile Canyon Fire west of Boulder, Colorado during cyclonic and convective rainstorms in the spring and summer of 2011. Some of the field measurements and measured soil physical properties were used to calibrate a one-dimensional post-wildfire numerical model, which was then used as a ‘virtual instrument’ to provide estimates of the saturated hydraulic conductivity and high-resolution (1 mm) estimates of the soil-water profile and water fluxes within the unsaturated zone.Field and model estimates of the wetting-front depth indicated that post-wildfire infiltration was on average confined to shallow depths less than 30 mm. Model estimates of the effective saturated hydraulic conductivity, Ks, near the soil surface ranged from 0.1 to 5.2 mm h−1. Because of the relatively small values of Ks, the time-to-start of runoff (measured from the start of rainfall), tp, was found to depend only on the initial soil-water saturation deficit (predicted by the model) and a measured characteristic of the rainfall profile (referred to as the average rainfall acceleration, equal to the initial rate of change in rainfall intensity). An analytical model was developed from the combined results and explained 92–97% of the variance of tp, and the numerical infiltration model explained 74–91% of the variance of the peak runoff rates. These results are from one burned site, but they strongly suggest that tp in fire-affected soils (which often have low values of Ks) is probably controlled more by the storm profile and the initial soil-water saturation deficit than by soil hydraulic properties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seifina, Elena; Titarchuk, Lev; Shaposhnikov, Nikolai, E-mail: seif@sai.msu.ru, E-mail: titarchuk@fe.infn.it, E-mail: lev@milkyway.gsfc.nasa.gov, E-mail: nikolai.v.shaposhnikov@nasa.gov
2014-07-01
We present the results of a comprehensive investigation on the evolution of spectral and timing properties of the Galactic black hole candidate 4U 1630-47 during its spectral transitions. In particular, we show how a scaling of the correlation of the photon index of the Comptonized spectral component Γ with low-frequency quasi-periodic oscillations (QPOs), ν {sub L}, and mass accretion rate, M-dot , can be applied to the black hole mass and the inclination angle estimates. We analyze the transition episodes observed with the Rossi X-Ray Timing Explorer and BeppoSAX satellites. We find that the broadband X-ray energy spectra of 4Umore » 1630-47 during all spectral states can be modeled by a combination of a thermal component, a Comptonized component, and a red-skewed iron-line component. We also establish that Γ monotonically increases during transition from the low-hard state to the high-soft state and then saturates for high mass accretion rates. The index saturation levels vary for different transition episodes. Correlations of Γ versus ν {sub L} also show saturation at Γ ∼ 3. Γ-- M-dot and Γ-ν {sub L} correlations with their index saturation revealed in 4U 1630-47 are similar to those established in a number of other black hole candidates and can be considered as an observational evidence for the presence of a black hole in these sources. The scaling technique, which relies on XTE J1550-564, GRO 1655-40, and H1743-322 as reference sources, allows us to evaluate a black hole mass in 4U 1630-47 yielding M {sub BH} ∼ 10 ± 0.1 solar masses and to constrain the inclination angle of i ≲ 70°.« less
Vogel, Laura J; Edge, Thomas A; O'Carroll, Denis M; Solo-Gabriele, Helena M; Kushnir, Caitlin S E; Robinson, Clare E
2017-09-15
Fecal indicator bacteria (FIB) are known to accumulate in foreshore beach sand and pore water (referred to as foreshore reservoir) where they act as a non-point source for contaminating adjacent surface waters. While guidelines exist for sampling surface waters at recreational beaches, there is no widely-accepted method to collect sand/sediment or pore water samples for FIB enumeration. The effect of different sampling strategies in quantifying the abundance of FIB in the foreshore reservoir is unclear. Sampling was conducted at six freshwater beaches with different sand types to evaluate sampling methods for characterizing the abundance of E. coli in the foreshore reservoir as well as the partitioning of E. coli between different components in the foreshore reservoir (pore water, saturated sand, unsaturated sand). Methods were evaluated for collection of pore water (drive point, shovel, and careful excavation), unsaturated sand (top 1 cm, top 5 cm), and saturated sand (sediment core, shovel, and careful excavation). Ankle-depth surface water samples were also collected for comparison. Pore water sampled with a shovel resulted in the highest observed E. coli concentrations (only statistically significant at fine sand beaches) and lowest variability compared to other sampling methods. Collection of the top 1 cm of unsaturated sand resulted in higher and more variable concentrations than the top 5 cm of sand. There were no statistical differences in E. coli concentrations when using different methods to sample the saturated sand. Overall, the unsaturated sand had the highest amount of E. coli when compared to saturated sand and pore water (considered on a bulk volumetric basis). The findings presented will help determine the appropriate sampling strategy for characterizing FIB abundance in the foreshore reservoir as a means of predicting its potential impact on nearshore surface water quality and public health risk. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hassler, E.; Corre, M. D.; Tjoa, A.; Damris, M.; Utami, S. R.; Veldkamp, E.
2015-06-01
Expansion of palm oil and rubber production, for which global demand is increasing, causes rapid deforestation in Sumatra, Indonesia and is expected to continue in the next decades. Our study aimed to (1) quantify changes in soil CO2 and CH4 fluxes with land-use change, and (2) determine their controlling factors. In Jambi Province, Sumatra, we selected two landscapes on heavily weathered soils that differ mainly in texture: loam and clay Acrisol soils. At each landscape, we investigated the reference land uses: forest and secondary forest with regenerating rubber, and the converted land uses: rubber (7-17 years old) and oil palm plantations (9-16 years old). We measured soil CO2 and CH4 fluxes monthly from December 2012 to December 2013. Annual soil CO2 fluxes from the reference land uses were correlated with soil fertility: low extractable phosphorus (P) coincided with high annual CO2 fluxes from the loam Acrisol soil that had lower fertility than the clay Acrisol soil (P < 0.05). Soil CO2 fluxes from the oil palm decreased compared to the other land uses (P < 0.01). Across land uses, annual CO2 fluxes were positively correlated with soil organic carbon (C) and negatively correlated with 15N signatures, extractable P and base saturation. This suggests that the reduced soil CO2 fluxes from oil palm was a result of strongly decomposed soil organic matter due to reduced litter input, and possible reduction in C allocation to roots due to improved soil fertility from liming and P fertilization in these plantations. Soil CH4 uptake in the reference land uses was negatively correlated with net nitrogen (N) mineralization and soil mineral N, suggesting N limitation of CH4 uptake, and positively correlated with exchangeable aluminum (Al), indicating decrease in methanotrophic activity at high Al saturation. Reduction in soil CH4 uptake in the converted land uses compared to the reference land uses (P < 0.01) was due to decrease in soil N availability in the converted land uses. Our study shows for the first time that differences in soil fertility control soil-atmosphere exchange of CO2 and CH4 in a tropical landscape, a mechanism that we were able to detect by conducting this study at the landscape scale.
Physicochemical application of capillary chromatography
NASA Astrophysics Data System (ADS)
Vasil'ev, A. V.; Aleksandrov, E. N.
1992-04-01
The application of capillary gas chromatography in the determination of the free energy, enthalpy, and entropy of sorption, the saturated vapour pressure and activity coefficients, the assessment of the lipophilicity of volatile compounds, and the study of the properties of polymers and liquid crystals is described. The use of reaction cappillary chromatography in kinetic studies of conformational conversions, thermal degradation, and photochemical reactions is examined. Studies on the use of capillary columns for determination of the second virial coefficients and viscosity of gases and the diffusion coefficients in gases, liquids, supercritical fluids, and polymers are analysed. The bibliography includes 114 references.
1980-08-01
been used in topical fluoride solutions applied to prevent caries . The use of SnF 2 . and similar chemical compounds, in the plating process appears to...Methods Tin fluoride solutions are prepared by dissolving SnF 2 in demineralized water at concentrations of 1, 5, 5.7, and 10%. The pH ranges from...saturated FeSO4 with or without 1 gpl thiourea a. .4 34 REFERENCES 1. P. Gron, "Chemistry of Topical Fluorides ", Caries Res. 11 (Suppl. 1): 172-204
NASA Technical Reports Server (NTRS)
Lorenz-Meyer, W.
1977-01-01
In connection with the question on the applicability of test results obtained from cryogenic wind tunnels to the large-scale model the similarity parameter is referred to. A simple method is given for calculating the similarity parameter. From the numerical values obtained it can be deduced that nitrogen behaves practically like an ideal gas when it is close to the saturation point and in a pressure range up to 4 bar. The influence of this parameter on the pressure distribution of a supercritical profile confirms this finding.
Liquefaction of Saturated Soil and the Diffusion Equation
NASA Astrophysics Data System (ADS)
Sawicki, Andrzej; Sławińska, Justyna
2015-06-01
The paper deals with the diffusion equation for pore water pressures with the source term, which is widely promoted in the marine engineering literature. It is shown that such an equation cannot be derived in a consistent way from the mass balance and the Darcy law. The shortcomings of the artificial source term are pointed out, including inconsistencies with experimental data. It is concluded that liquefaction and the preceding process of pore pressure generation and the weakening of the soil skeleton should be described by constitutive equations within the well-known framework of applied mechanics. Relevant references are provided
Digital-computer program for design analysis of salient, wound pole alternators
NASA Technical Reports Server (NTRS)
Repas, D. S.
1973-01-01
A digital computer program for analyzing the electromagnetic design of salient, wound pole alternators is presented. The program, which is written in FORTRAN 4, calculates the open-circuit saturation curve, the field-current requirements at rated voltage for various loads and losses, efficiency, reactances, time constants, and weights. The methods used to calculate some of these items are presented or appropriate references are cited. Instructions for using the program and typical program input and output for an alternator design are given, and an alphabetical list of most FORTRAN symbols and the complete program listing with flow charts are included.
Multi-element screening by ICP-MS of two specimens of Napoleon's hair.
Kintz, Pascal; Ginet, Morgane; Cirimele, Vincent
2006-10-01
Since 1960, it has been demonstrated by various analytical procedures that high concentrations of arsenic were present in Napoleon's hair. Various authors, indicating that the detected arsenic levels are a consequence of external contamination, have challenged the results of these examinations. In order to shed more light on this historical controversy, we have tested two samples of Napoleon's hair by inductively coupled plasma-mass spectrometry (ICP-MS). The samples of hair were decontaminated with acetone and were cut into small segments. For multi-element screening, hair samples were mineralized in concentrated nitric acid for 1 h at 70 degrees C, diluted 1:40 in specific solution with rhodium as an internal standard, and finally analyzed by ICP-MS on a Thermo Electron ICP/MS X7. Multi-element analysis of Napoleon's hair samples revealed massive amounts of arsenic (42.1 and 37.4 ng/mg), antimony (2.1 and 1.8 ng/mg) and elevated levels of mercury (3.3 and 4.7 ng/mg) and lead (229 and 112 ng/mg). In the case of arsenic, these concentrations, 40 times higher than the normal values, confirm the hypothesis of a significant exposure to arsenic. The concentrations of the other elements, in particular antimony and mercury, are in agreement with the data already known about the therapeutic treatments given to Napoleon, which were based on calomel (salt of mercury) and tartar emetic (antimony).
Fast imaging of laboratory core floods using 3D compressed sensing RARE MRI.
Ramskill, N P; Bush, I; Sederman, A J; Mantle, M D; Benning, M; Anger, B C; Appel, M; Gladden, L F
2016-09-01
Three-dimensional (3D) imaging of the fluid distributions within the rock is essential to enable the unambiguous interpretation of core flooding data. Magnetic resonance imaging (MRI) has been widely used to image fluid saturation in rock cores; however, conventional acquisition strategies are typically too slow to capture the dynamic nature of the displacement processes that are of interest. Using Compressed Sensing (CS), it is possible to reconstruct a near-perfect image from significantly fewer measurements than was previously thought necessary, and this can result in a significant reduction in the image acquisition times. In the present study, a method using the Rapid Acquisition with Relaxation Enhancement (RARE) pulse sequence with CS to provide 3D images of the fluid saturation in rock core samples during laboratory core floods is demonstrated. An objective method using image quality metrics for the determination of the most suitable regularisation functional to be used in the CS reconstructions is reported. It is shown that for the present application, Total Variation outperforms the Haar and Daubechies3 wavelet families in terms of the agreement of their respective CS reconstructions with a fully-sampled reference image. Using the CS-RARE approach, 3D images of the fluid saturation in the rock core have been acquired in 16min. The CS-RARE technique has been applied to image the residual water saturation in the rock during a water-water displacement core flood. With a flow rate corresponding to an interstitial velocity of vi=1.89±0.03ftday(-1), 0.1 pore volumes were injected over the course of each image acquisition, a four-fold reduction when compared to a fully-sampled RARE acquisition. Finally, the 3D CS-RARE technique has been used to image the drainage of dodecane into the water-saturated rock in which the dynamics of the coalescence of discrete clusters of the non-wetting phase are clearly observed. The enhancement in the temporal resolution that has been achieved using the CS-RARE approach enables dynamic transport processes pertinent to laboratory core floods to be investigated in 3D on a time-scale and with a spatial resolution that, until now, has not been possible. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Schöpfer, Martin; Lehner, Florian; Grasemann, Bernhard; Kaserer, Klemens; Hinsch, Ralph
2017-04-01
John G. Ramsay's sketch of structures developed in a layer progressively folded and deformed by tangential longitudinal strain (Figure 7-65 in Folding and Fracturing of Rocks) and the associated strain pattern analysis have been reproduced in many monographs on Structural Geology and are referred to in numerous publications. Although the origin of outer-arc extension fractures is well-understood and documented in many natural examples, geomechanical factors controlling their (finite or saturation) spacing are hitherto unexplored. This study investigates the formation of bending-induced fractures during constant-curvature forced folding using Distinct Element Method (DEM) numerical modelling. The DEM model comprises a central brittle layer embedded within weaker (low modulus) elastic layers; the layer interfaces are frictionless (free slip). Folding of this three-layer system is enforced by a velocity boundary condition at the model base, while a constant overburden pressure is maintained at the model top. The models illustrate several key stages of fracture array development: (i) Prior to the onset of fracture, the neutral surface is located midway between the layer boundaries; (ii) A first set of regularly spaced fractures develops once the tensile stress in the outer-arc equals the tensile strength of the layer. Since the layer boundaries are frictionless, these bending-induced fractures propagate through the entire layer; (iii) After the appearance of the first fracture set, the rate of fracture formation decreases rapidly and so-called infill fractures develop approximately midway between two existing fractures (sequential infilling); (iv) Eventually no new fractures form, irrespective of any further increase in fold curvature (fracture saturation). Analysis of the interfacial normal stress distributions suggests that at saturation the fracture-bound blocks are subjected to a loading condition similar to three-point bending. Using classical beam theory an analytical solution is derived for the critical fracture spacing, i.e. the spacing below which the maximum tensile stress cannot reach the layer strength. The model results are consistent with an approximate analytical solution, and illustrate that the spacing of bending-induced fractures is proportional to layer thickness and a square root function of the ratio of layer tensile strength to confining pressure. Although highly idealised, models and analysis presented in this study offer an explanation for fracture saturation during folding and point towards certain key factors that may control fracture spacing in natural systems.
Picotti, Paola; Clement-Ziza, Mathieu; Lam, Henry; Campbell, David S.; Schmidt, Alexander; Deutsch, Eric W.; Röst, Hannes; Sun, Zhi; Rinner, Oliver; Reiter, Lukas; Shen, Qin; Michaelson, Jacob J.; Frei, Andreas; Alberti, Simon; Kusebauch, Ulrike; Wollscheid, Bernd; Moritz, Robert; Beyer, Andreas; Aebersold, Ruedi
2013-01-01
Complete reference maps or datasets, like the genomic map of an organism, are highly beneficial tools for biological and biomedical research. Attempts to generate such reference datasets for a proteome so far failed to reach complete proteome coverage, with saturation apparent at approximately two thirds of the proteomes tested, even for the most thoroughly characterized proteomes. Here, we used a strategy based on high-throughput peptide synthesis and mass spectrometry to generate a close to complete reference map (97% of the genome-predicted proteins) of the S. cerevisiae proteome. We generated two versions of this mass spectrometric map one supporting discovery- (shotgun) and the other hypothesis-driven (targeted) proteomic measurements. The two versions of the map, therefore, constitute a complete set of proteomic assays to support most studies performed with contemporary proteomic technologies. The reference libraries can be browsed via a web-based repository and associated navigation tools. To demonstrate the utility of the reference libraries we applied them to a protein quantitative trait locus (pQTL) analysis, which requires measurement of the same peptides over a large number of samples with high precision. Protein measurements over a set of 78 S. cerevisiae strains revealed a complex relationship between independent genetic loci, impacting on the levels of related proteins. Our results suggest that selective pressure favors the acquisition of sets of polymorphisms that maintain the stoichiometry of protein complexes and pathways. PMID:23334424
Greenhouse Gas Emissions from Green Infrastructure vs. Conventional Wastewater Treatment Plants
NASA Astrophysics Data System (ADS)
Morse, N.; Walter, T.
2017-12-01
The need for resilient infrastructure and cities in the face of climate change has prompted an expansion of green infrastructure (GI) in suburban and urban areas. However, some researchers have begun to question if these engineered and vegetated systems could be contributing excess greenhouse gas (GHG) emissions. They theorize that the often inundated GI practices may be hot-spots for biogeochemical processes emitting GHGs. However, no studies have compared passive GI to the only available alternative for water treatment: conventional wastewater treatment plants (WWTPs). This study monitored the nitrous oxide (N2O) and methane (CH4) emissions from two GI detention basins in Ithaca, NY and compared these emissions with reported and modeled on-site emissions from WWTPs. One basin was often saturated ("Wet Basin"), while the other drained quickly and was rarely saturated ("Dry Basin"). The Wet Basin emitted more GHGs than nearby reference turfgrass (92 vs. 5 mg CO2 eq m-2 hr-), while the Dry Basin emitted less than reference turfgrass (0.9 vs 4 mg CO2 eq m-2 hr-). However, both basins emitted far less GHGs than conventional WWTPs. According to EPA calculations, aerobic WWTPs emit approximately 1,079 mg CO2 eq L-1, and the Wet and Dry Basin emitted roughly 117-516 and 0.28-2.56 mg CO2 eq L-1, respectively. Thus, on a per volume of water treated basis, conventional WWTPs are emitting approximately 3 and 750 times more GHGs than GI Wet and Dry Basins, respectively. This study highlights how passive GI provides a valuable ecosystem service (i.e., stormwater treatment) while producing less GHGs than WWTPs.
Skibinski, David O. F.
2018-01-01
Nutrient acquisition is a critical determinant for the competitive advantage for auto- and osmohetero- trophs alike. Nutrient limited growth is commonly described on a whole cell basis through reference to a maximum growth rate (Gmax) and a half-saturation constant (KG). This empirical application of a Michaelis-Menten like description ignores the multiple underlying feedbacks between physiology contributing to growth, cell size, elemental stoichiometry and cell motion. Here we explore these relationships with reference to the kinetics of the nutrient transporter protein, the transporter rate density at the cell surface (TRD; potential transport rate per unit plasma-membrane area), and diffusion gradients. While the half saturation value for the limiting nutrient increases rapidly with cell size, significant mitigation is afforded by cell motion (swimming or sedimentation), and by decreasing the cellular carbon density. There is thus potential for high vacuolation and high sedimentation rates in diatoms to significantly decrease KG and increase species competitive advantage. Our results also suggest that Gmax for larger non-diatom protists may be constrained by rates of nutrient transport. For a given carbon density, cell size and TRD, the value of Gmax/KG remains constant. This implies that species or strains with a lower Gmax might coincidentally have a competitive advantage under nutrient limited conditions as they also express lower values of KG. The ability of cells to modulate the TRD according to their nutritional status, and hence change the instantaneous maximum transport rate, has a very marked effect upon transport and growth kinetics. Analyses and dynamic models that do not consider such modulation will inevitably fail to properly reflect competitive advantage in nutrient acquisition. This has important implications for the accurate representation and predictive capabilities of model applications, in particular in a changing environment. PMID:29702650
NASA Astrophysics Data System (ADS)
Abbas, M.; Jardani, A.; Soueid Ahmed, A.; Revil, A.; Brigaud, L.; Bégassat, Ph.; Dupont, J. P.
2017-11-01
Mapping the redox potential of shallow aquifers impacted by hydrocarbon contaminant plumes is important for the characterization and remediation of such contaminated sites. The redox potential of groundwater is indicative of the biodegradation of hydrocarbons and is important in delineating the shapes of contaminant plumes. The self-potential method was used to reconstruct the redox potential of groundwater associated with an organic-rich contaminant plume in northern France. The self-potential technique is a passive technique consisting in recording the electrical potential distribution at the surface of the Earth. A self-potential map is essentially the sum of two contributions, one associated with groundwater flow referred to as the electrokinetic component, and one associated with redox potential anomalies referred to as the electroredox component (thermoelectric and diffusion potentials are generally negligible). A groundwater flow model was first used to remove the electrokinetic component from the observed self-potential data. Then, a residual self-potential map was obtained. The source current density generating the residual self-potential signals is assumed to be associated with the position of the water table, an interface characterized by a change in both the electrical conductivity and the redox potential. The source current density was obtained through an inverse problem by minimizing a cost function including a data misfit contribution and a regularizer. This inversion algorithm allows the determination of the vertical and horizontal components of the source current density taking into account the electrical conductivity distribution of the saturated and non-saturated zones obtained independently by electrical resistivity tomography. The redox potential distribution was finally determined from the inverted residual source current density. A redox map was successfully built and the estimated redox potential values correlated well with in-situ measurements.
NASA Astrophysics Data System (ADS)
Brown, Richard J. C.; Brewer, Paul J.; Ent, Hugo; Fisicaro, Paola; Horvat, Milena; Kim, Ki-Hyun; Quétel, Christophe R.
2015-10-01
This paper considers how decisions on internationally recommended datasets are made and implemented and, further, how the ownership of these decisions comes about. Examples are given of conventionally agreed data and values where the responsibility is clear and comes about through official designation or by common usage and practice over long time periods. The example of the dataset describing the mass concentration of mercury in air at saturation is discussed in detail. This is a case where there are now several competing datasets that are in disagreement with each other, some with historical authority and some more recent but, arguably, with more robust metrological traceability to the SI. Further, it is elaborated that there is no body charged with the responsibility to make a decision on an international recommendation for such a dataset. This has led to the situation where several competing datasets are in use simultaneously. Close parallels are drawn with the current debate over changes to the ozone absorption cross section, which has equal importance to the measurement of ozone amount fraction in air and to subsequent compliance with air quality legislation. It is noted that in the case of the ozone cross section there is already a committee appointed to deliberate over any change. We make the proposal that a similar committee, under the auspices of IUPAC or the CIPM’s CCQM (if it adopted a reference data function) could be formed to perform a similar role for the mass concentration of mercury in air at saturation.
Terminology gap in hydrological cycle
NASA Astrophysics Data System (ADS)
Zhuo, Lu; Han, Dawei
2016-04-01
Water is central to life on Earth. People have been trying to understand how water moves in the hydrosphere throughout the human history. In the 9th century BC, the famous Greek poet Homer described the hydrological cycle in Iliad as "okeanos whose stream bends back in a circle" with a belief that rivers are ocean-fed from subterranean seas. Later, Aristotle (4th century BC) claimed that most of the water came from underground caverns in which air was transformed into water. It was only until 1674, French scientist Perrault developed the correct concept of the water cycle. In modern times, scientists are interested in understanding the individual processes of the hydrological cycle with a keen focus on runoff which supplies water to rivers, lakes, and oceans. Currently, the prevailing concepts on runoff processes include 'infiltration excess runoff' and 'saturation excess runoff'. However, there is no term to describe another major runoff due to the excess beyond the soil water holding capacity (i.e., the field capacity). We argue that a new term should be introduced to fill this gap, and it could be called 'holding excess runoff' which is compatible with the convention. This new term is significant in correcting a half-century misnomer where 'holding excess runoff' has been incorrectly named as 'saturation excess runoff', which was introduced by the Xinanjiang model in China in 1960s. Similar concept has been adopted in many well-known hydrological models such as PDM and HBV in which the saturation refers to the field capacity. The term 'holding excess runoff' resolves such a common confusion in the hydrological community.
Relative Humidity in the Tropopause Saturation Layer
NASA Astrophysics Data System (ADS)
Selkirk, H. B.; Schoeberl, M. R.; Pfister, L.; Thornberry, T. D.; Bui, T. V.
2017-12-01
The tropical tropopause separates two very different atmospheric regimes: the stable lower stratosphere where the air is both extremely dry and nearly always so, and a transition layer in the uppermost tropical troposphere, where humidity on average increases rapidly downward but can undergo substantial temporal fluctuations. The processes that control the humidity in this layer below the tropopause include convective detrainment (which can result in either a net hydration or dehydration), slow ascent, wave motions and advection. Together these determine the humidity of the air that eventually passes through the tropopause and into the stratosphere, and we refer to this layer as the tropopause saturation layer or TSL. We know from in situ water vapor observations such as Ticosonde's 12-year balloonsonde record at Costa Rica that layers of supersaturation are frequently observed in the TSL. While their frequency is greatest during the local rainy season from June through October, supersaturation is also observed in the boreal winter dry season when deep convection is well south of Costa Rica. In other words, local convection is not a necessary condition for the presence of supersaturation. Furthermore, there are indications from airborne measurements during the recent POSIDON campaign at Guam that if anything deep convection tends to `reset' the TSL locally to a state of just-saturation. Conversely, it may be that layers of supersaturation are the result of slow ascent. To explore these ideas we take Ticosonde water vapor observations from the TSL, stratify them on the basis of relative humidity and report on the differences in the the history of upstream convective influence between supersaturated parcels and those that are not.
Daryaei, Iman; Pagel, Mark D
2015-01-01
Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.
Daryaei, Iman; Pagel, Mark D
2016-01-01
Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a “double-agent” approach to molecular imaging. Exogenous T2-exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T1 and T2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as “secret agents” in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging. PMID:27747191
Reference values for pulse oximetry at high altitude
Gamponia, M; Babaali, H; Yugar, F; Gilman, R
1998-01-01
OBJECTIVE—To determine reference values for oxygen saturation (SaO2) in healthy children younger than 5 years living at high altitude. DESIGN—One hundred and sixty eight children were examined for SaO2 at 4018 m during well child visits. Physiological state was also noted during the examination. RESULTS—The mean SaO2 was 87.3% (95% confidence intervals (CI) 86.7%, 87.9%) with a median value of 87.7%. A significant difference was observed in SaO2 between children younger than 1 year compared with older children, although the difference was no longer demonstrable when sleeping children were excluded. CONCLUSIONS—This study has provided a reference range of SaO2 values for healthy children under 5 years old so that pulse oximetry may be used as an adjunct in diagnosing acute respiratory infections. Younger children were also shown to have a lower mean SaO2 than older children living at high altitude, which suggests physiological adaptation to high altitude over time. In addition, sleep had a lowering effect on SaO2, although the clinical importance of this remains undetermined. PMID:9659095
Ikeda, Keita; MacLeod, David B; Grocott, Hilary P.; Moretti, Eugene W.; Ames, Warwick; Vacchiano, Charles
2014-01-01
Background An intriguing potential clinical use of cerebral oximeter measurements (SctO2) is the ability to noninvasively estimate jugular bulb venous oxygen saturation (SjvO2). Our purpose in this study was to determine the accuracy of the FORE-SIGHT® (CAS Medical Systems; Branford, CT), which is calibrated to a weighted average of 70% (SjvO2) and 30% arterial saturation, for Food and Drug Administration pre-market approval 510 (k) certification by adapting an industry standard protocol, ISO 9919:2005 [www.ISO.org] (used for pulse oximeters) and to evaluate the use of SctO2 and SpO2 measurements to noninvasively estimate jugular venous oxygen saturation (SnvO2). Methods Paired blood gas samples from the radial artery and the jugular venous bulb were collected from 20 healthy volunteers undergoing progressive oxygen desaturation from 100 to 70%. The blood sample pairs were analyzed via co-oximetry and used to calculate the approximate mixed vascular cerebral blood oxygen saturation, or reference SctO2 values (refSctO2), during increasing hypoxia. These reference values were compared to bilateral FORE-SIGHT SctO2 values recorded simultaneously with the blood gas draws to determine its accuracy. Bilateral SctO2 and SpO2 measurements were then used to calculate SnvO2 values which were compared to SjvO2. Results Two hundred forty-six arterial and 253 venous samples from 18 subjects were used in the analysis. The ipsilateral FORE-SIGHT SctO2 values showed a tolerance interval (TI) of [−10.72 10.90] Lin’s concordance correlation coefficient (CCC) with standard error (SE) of 0.83 ± 0.073 with the refSctO2 values calculated using arterial and venous blood gases. The combined data had a CCC of 0. 81 + 0.059 with TI of [−9.22 9.40] with overall bias was 0.09% and amplitude of the root mean square of error after it was corrected with random effects analysis was 2.92%. The bias and variability values between the ipsilateral and the contralateral FORE-SIGHT SctO2 measurements varied from person to person. The SnvO2 calculated from the ipsilateral SctO2 and SpO2 data showed a CCC + SE of 0.79 ± 0.088, TI = [−14.93 15.33], slope of 0.98, Y-Intercept of 1.14%) with SjvO2 values with a bias of 0.20% and an Arms of 4.08%. The SnvO2 values calculated independently from contralateral forehead FORE-SIGHT SctO2 values were not as correlated with the SjvO2 values (contralateral side CCC + SE = 0.72 ± 0.118, TI = [−14.86 15.20], slope of 0.66 and y-intercept of 20.36%). Conclusions The FORE-SIGHT cerebral oximeter was able to estimate oxygen saturation within the tissues of the frontal lobe under conditions of normocapnia and varying degrees of hypoxia (with 95% confidence interval of [−5.60 5.78] with ipsilateral blood ample data). These findings from healthy volunteers also suggest that the use of the calculated SnvO2 derived from SctO2 and SpO2 values may be a reasonable noninvasive method of estimating SjvO2 and therefore global cerebral oxygen consumption in the clinical setting. Further laboratory and clinical research is required to define the clinical utility of near-infrared spectroscopy determination of SctO2 and SnvO2 in the operating room setting. PMID:25313967
Ikeda, Keita; MacLeod, David B; Grocott, Hilary P; Moretti, Eugene W; Ames, Warwick; Vacchiano, Charles
2014-12-01
An intriguing potential clinical use of cerebral oximeter measurements (SctO2) is the ability to noninvasively estimate jugular bulb venous oxygen saturation (SjvO2). Our purpose in this study was to determine the accuracy of the FORE-SIGHT(®) (CAS Medical Systems, Branford, CT), which is calibrated to a weighted average of 70% (SjvO2) and 30% arterial saturation, for Food and Drug Administration pre-market approval 510(k) certification by adapting an industry standard protocol, ISO 9919:2005 (www.ISO.org) (used for pulse oximeters), and to evaluate the use of SctO2 and SpO2 measurements to noninvasively estimate jugular venous oxygen saturation (SnvO2). Paired blood gas samples from the radial artery and the jugular venous bulb were collected from 20 healthy volunteers undergoing progressive oxygen desaturation from 100% to 70%. The blood sample pairs were analyzed via co-oximetry and used to calculate the approximate mixed vascular cerebral blood oxygen saturation, or reference SctO2 values (refSctO2), during increasing hypoxia. These reference values were compared to bilateral FORE-SIGHT SctO2 values recorded simultaneously with the blood gas draws to determine its accuracy. Bilateral SctO2 and SpO2 measurements were then used to calculate SnvO2 values which were compared to SjvO2. Two hundred forty-six arterial and 253 venous samples from 18 subjects were used in the analysis. The ipsilateral FORE-SIGHT SctO2 values showed a tolerance interval (TI) of [-10.72 to 10.90] and Lin concordance correlation coefficient (CCC) with standard error (SE) of 0.83 ± 0.073 with the refSctO2 values calculated using arterial and venous blood gases. The ipsilateral data had a CCC of 0.81 + 0.059 with TI of [-9.22 to 9.40] with overall bias of 0.09%, and amplitude of the root mean square of error after it was corrected with random effects analysis was 2.92%. The bias and variability values between the ipsilateral and the contralateral FORE-SIGHT SctO2 measurements varied from person to person. The SnvO2 calculated from the ipsilateral SctO2 and SpO2 data showed a CCC ± SE of 0.79 ± 0.088, TI = [-14.93 to 15.33], slope of 0.98, y-intercept of 1.14% with SjvO2 values with a bias of 0.20% and an Arms of 4.08%. The SnvO2 values calculated independently from contralateral forehead FORE-SIGHT SctO2 values were not as correlated with the SjvO2 values (contralateral side CCC + SE = 0.72 ± 0.118, TI = [-14.86 to 15.20], slope of 0.66, and y-intercept of 20.36%). The FORE-SIGHT cerebral oximeter was able to estimate oxygen saturation within the tissues of the frontal lobe under conditions of normocapnia and varying degrees of hypoxia (with 95% confidence interval of [-5.60 to 5.78] with ipsilateral blood sample data). These findings from healthy volunteers also suggest that the use of the calculated SnvO2 derived from SctO2 and SpO2 values may be a reasonable noninvasive method of estimating SjvO2 and therefore global cerebral oxygen consumption in the clinical setting. Further laboratory and clinical research is required to define the clinical utility of near-infrared spectroscopy determination of SctO2 and SnvO2 in the operating room setting.
Remote sensing of stress using electro-optics imaging technique
NASA Astrophysics Data System (ADS)
Chen, Tong; Yuen, Peter; Hong, Kan; Tsitiridis, Aristeidis; Kam, Firmin; Jackman, James; James, David; Richardson, Mark; Oxford, William; Piper, Jonathan; Thomas, Francis; Lightman, Stafford
2009-09-01
Emotional or physical stresses induce a surge of adrenaline in the blood stream under the command of the sympathetic nerve system, which, cannot be suppressed by training. The onset of this alleviated level of adrenaline triggers a number of physiological chain reactions in the body, such as dilation of pupil and an increased feed of blood to muscles etc. This paper reports for the first time how Electro-Optics (EO) technologies such as hyperspectral [1,2] and thermal imaging[3] methods can be used for the detection of stress remotely. Preliminary result using hyperspectral imaging technique has shown a positive identification of stress through an elevation of haemoglobin oxygenation saturation level in the facial region, and the effect is seen more prominently for the physical stressor than the emotional one. However, all results presented so far in this work have been interpreted together with the base line information as the reference point, and that really has limited the overall usefulness of the developing technology. The present result has highlighted this drawback and it prompts for the need of a quantitative assessment of the oxygenation saturation and to correlate it directly with the stress level as the top priority of the next stage of research.
Laboratory meter-scale seismic monitoring of varying water levels in granular media
NASA Astrophysics Data System (ADS)
Pasquet, S.; Bodet, L.; Bergamo, P.; Guérin, R.; Martin, R.; Mourgues, R.; Tournat, V.
2016-12-01
Laboratory physical modelling and non-contacting ultrasonic techniques are frequently proposed to tackle theoretical and methodological issues related to geophysical prospecting. Following recent developments illustrating the ability of seismic methods to image spatial and/or temporal variations of water content in the vadose zone, we developed laboratory experiments aimed at testing the sensitivity of seismic measurements (i.e., pressure-wave travel times and surface-wave phase velocities) to water saturation variations. Ultrasonic techniques were used to simulate typical seismic acquisitions on small-scale controlled granular media presenting different water levels. Travel times and phase velocity measurements obtained at the dry state were validated with both theoretical models and numerical simulations and serve as reference datasets. The increasing water level clearly affects the recorded wave field in both its phase and amplitude, but the collected data cannot yet be inverted in the absence of a comprehensive theoretical model for such partially saturated and unconsolidated granular media. The differences in travel time and phase velocity observed between the dry and wet models show patterns that are interestingly coincident with the observed water level and depth of the capillary fringe, thus offering attractive perspectives for studying soil water content variations in the field.
Visualizing photosynthesis through processing of chlorophyll fluorescence images
NASA Astrophysics Data System (ADS)
Daley, Paul F.; Ball, J. Timothy; Berry, Joseph A.; Patzke, Juergen; Raschke, Klaus E.
1990-05-01
Measurements of terrestrial plant photosynthesis frequently exploit sensing of gas exchange from leaves enclosed in gas-tight, climate controlled chambers. These methods are typically slow, and do not resolve variation in photosynthesis below the whole leaf level. A photosynthesis visualization technique is presented that uses images of leaves employing light from chlorophyll (Chl) fluorescence. Images of Chl fluorescence from whole leaves undergoing steady-state photosynthesis, photosynthesis induction, or response to stress agents were digitized during light flashes that saturated photochemical reactions. Use of saturating flashes permitted deconvolution of photochemical energy use from biochemical quenching mechanisms (qN) that dissipate excess excitation energy, otherwise damaging to the light harvesting apparatus. Combination of the digital image frames of variable fluorescence with reference frames obtained from the same leaves when dark-adapted permitted derivation of frames in which grey scale represented the magnitude of qN. Simultaneous measurements with gas-exchange apparatus provided data for non-linear calibration filters for subsequent rendering of grey-scale "images" of photosynthesis. In several experiments significant non-homogeneity of photosynthetic activity was observed following treatment with growth hormones, or shifts in light or humidity, and following infection by virus. The technique provides a rapid, non-invasive probe for stress physiology and plant disease detection.
Zhang, Shu-Xin; Chai, Xin-Sheng; Barnes, Donald G
2016-02-26
This study reports a new headspace gas chromatographic method (HS-GC) for the determination of water solubility of low volatility liquid organic compounds (LVLOs). The HS-GC analysis was performed on a set of aqueous solutions containing a range of concentrations of toluene-spiked (as a tracer) LVLOs, from under-saturation to over-saturation. A plot of the toluene tracer GC signal vs. the concentration of the LVLO results in two lines of different slopes that intersect at the concentration corresponding to the compound's solubility in water. The results showed that the HS-GC method has good precision (RSD <6.3%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 6.0%. The HS-GC method is simple and particularly suitable for measuring the solubility of LVLOs at elevated temperatures. This approach should be of special interest to those concerned about the impact of the presence of low-volatility organic liquids in waters of environmental and biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.
Mirror instability near the threshold: Hybrid simulations
NASA Astrophysics Data System (ADS)
Hellinger, P.; Trávníček, P.; Passot, T.; Sulem, P.; Kuznetsov, E. A.; Califano, F.
2007-12-01
Nonlinear behavior of the mirror instability near the threshold is investigated using 1-D hybrid simulations. The simulations demonstrate the presence of an early phase where quasi-linear effects dominate [ Shapiro and Shevchenko, 1964]. The quasi-linear diffusion is however not the main saturation mechanism. A second phase is observed where the mirror mode is linearly stable (the stability is evaluated using the instantaneous ion distribution function) but where the instability nevertheless continues to develop, leading to nonlinear coherent structures in the form of magnetic humps. This regime is well modeled by a nonlinear equation for the magnetic field evolution, derived from a reductive perturbative expansion of the Vlasov-Maxwell equations [ Kuznetsov et al., 2007] with a phenomenological term which represents local variations of the ion Larmor radius. In contrast with previous models where saturation is due to the cooling of a population of trapped particles, the resulting equation correctly reproduces the development of magnetic humps from an initial noise. References Kuznetsov, E., T. Passot and P. L. Sulem (2007), Dynamical model for nonlinear mirror modes near threshold, Phys. Rev. Lett., 98, 235003. Shapiro, V. D., and V. I. Shevchenko (1964), Sov. JETP, 18, 1109.
Enhanced sorption of trichloroethene by smectite clay exchanged with Cs+.
Aggarwal, Vaneet; Li, Hui; Boyd, Stephen A; Teppen, Brian J
2006-02-01
Trichloroethene (TCE) is one of the most common pollutants in groundwater, and Cs+ can be a cocontaminant at nuclear facilities. Smectite clays have large surface areas, are common in soils, have high affinities for some organic contaminants, and hence can potentially influence the transport of organic pollutants entering soils and sediments. The exchangeable cations present near smectite clay surfaces can radically influence the sorption of organic pollutants by soil clays. This research was undertaken to determine the effect of Cs+, and other common interlayer cations, such as K+ and Ca2+, on the sorption of TCE by a reference smectite clay saponite. Cs-saturated clay sorbed the most TCE, up to 3500 mg/kg, while Ca-saturated smectite sorbed the least. We hypothesize that the stronger sorption of TCE by the Cs-smectite can be attributed to the lower hydration energy and hence smaller hydrated radius of Cs+, which expands the lateral clay surface domains available for sorption. Also, Cs-smectite interlayers are only one or two water layers thick, which may drive capillary condensation of TCE. Our results implicate enhanced retention of TCE in aquifer materials containing smectites accompanied by Cs+ cocontamination.
Capillary and Gas Trapping Controls on Pumice Buoyancy in Water
NASA Astrophysics Data System (ADS)
Fauria, K. E.; Manga, M.; Wei, Z.
2016-12-01
Pumice can float on water for months to years. The longevity of pumice floatation is unexpected, however, because pumice pores are highly connected and water wets volcanic glass. As a result, observations of long floating times have not been reconciled with predictions of rapid sinking. We propose a mechanism to resolve this paradox - the trapping of gas bubbles by water within the pumice. Gas trapping refers to the isolation of gas by water within pore throats such that the gas becomes disconnected from the atmosphere and unable to escape. We use X-ray microtomography images of partially saturated pumice to demonstrate that gas trapping occurs in both ambient-temperature and hot (500°C) pumice. Furthermore, we show that the distribution of trapped gas clusters matches percolation theory predictions. Finally, we propose that diffusion out of trapped gaseous bubbles determines pumice floatation time. Experimental measurements of pumice floatation support a diffusion control on pumice buoyancy and we find that floatation time scales like τ L2/(Dθ2) where is the floatation time, L is the characteristic length of the pumice, D is the gas-water diffusion coefficient, and θ is pumice water saturation.
Reactive Gas transport in soil: Kinetics versus Local Equilibrium Approach
NASA Astrophysics Data System (ADS)
Geistlinger, Helmut; Jia, Ruijan
2010-05-01
Gas transport through the unsaturated soil zone was studied using an analytical solution of the gas transport model that is mathematically equivalent to the Two-Region model. The gas transport model includes diffusive and convective gas fluxes, interphase mass transfer between the gas and water phase, and biodegradation. The influence of non-equilibrium phenomena, spatially variable initial conditions, and transient boundary conditions are studied. The objective of this paper is to compare the kinetic approach for interphase mass transfer with the standard local equilibrium approach and to find conditions and time-scales under which the local equilibrium approach is justified. The time-scale of investigation was limited to the day-scale, because this is the relevant scale for understanding gas emission from the soil zone with transient water saturation. For the first time a generalized mass transfer coefficient is proposed that justifies the often used steady-state Thin-Film mass transfer coefficient for small and medium water-saturated aggregates of about 10 mm. The main conclusion from this study is that non-equilibrium mass transfer depends strongly on the temporal and small-scale spatial distribution of water within the unsaturated soil zone. For regions with low water saturation and small water-saturated aggregates (radius about 1 mm) the local equilibrium approach can be used as a first approximation for diffusive gas transport. For higher water saturation and medium radii of water-saturated aggregates (radius about 10 mm) and for convective gas transport, the non-equilibrium effect becomes more and more important if the hydraulic residence time and the Damköhler number decrease. Relative errors can range up to 100% and more. While for medium radii the local equilibrium approach describes the main features both of the spatial concentration profile and the time-dependence of the emission rate, it fails completely for larger aggregates (radius about 100 mm). From the comparative study of relevant scenarios with and without biodegradation it can be concluded that, under realistic field conditions, biodegradation within the immobile water phase is often mass-transfer limited and the local equilibrium approach assuming instantaneous mass transfer becomes rather questionable. References Geistlinger, H., Ruiyan Jia, D. Eisermann, and C.-F. Stange (2008): Spatial and temporal variability of dissolved nitrous oxide in near-surface groundwater and bubble-mediated mass transfer to the unsaturated zone, J. Plant Nutrition and Soil Science, in press. Geistlinger, H. (2009) Vapor transport in soil: concepts and mathematical description. In: Eds.: S. Saponari, E. Sezenna, and L. Bonoma, Vapor emission to outdoor air and enclosed spaces for human health risk assessment: Site characterization, monitoring, and modeling. Nova Science Publisher. Milano. Accepted for publication.
High-Energy Passive Mode-Locking of Fiber Lasers
Ding, Edwin; Renninger, William H.; Wise, Frank W.; Grelu, Philippe; Shlizerman, Eli; Kutz, J. Nathan
2012-01-01
Mode-locking refers to the generation of ultrashort optical pulses in laser systems. A comprehensive study of achieving high-energy pulses in a ring cavity fiber laser that is passively mode-locked by a series of waveplates and a polarizer is presented in this paper. Specifically, it is shown that the multipulsing instability can be circumvented in favor of bifurcating to higher-energy single pulses by appropriately adjusting the group velocity dispersion in the fiber and the waveplate/polarizer settings in the saturable absorber. The findings may be used as practical guidelines for designing high-power lasers since the theoretical model relates directly to the experimental settings. PMID:22866059
Astrometric and Photometric Analysis of the September 2008 ATV-1 Re-Entry Event
NASA Technical Reports Server (NTRS)
Mulrooney, Mark K.; Barker, Edwin S.; Maley, Paul D.; Beaulieu, Kevin R.; Stokely, Christopher L.
2008-01-01
NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming.
Dynamics and control of quadcopter using linear model predictive control approach
NASA Astrophysics Data System (ADS)
Islam, M.; Okasha, M.; Idres, M. M.
2017-12-01
This paper investigates the dynamics and control of a quadcopter using the Model Predictive Control (MPC) approach. The dynamic model is of high fidelity and nonlinear, with six degrees of freedom that include disturbances and model uncertainties. The control approach is developed based on MPC to track different reference trajectories ranging from simple ones such as circular to complex helical trajectories. In this control technique, a linearized model is derived and the receding horizon method is applied to generate the optimal control sequence. Although MPC is computer expensive, it is highly effective to deal with the different types of nonlinearities and constraints such as actuators’ saturation and model uncertainties. The MPC parameters (control and prediction horizons) are selected by trial-and-error approach. Several simulation scenarios are performed to examine and evaluate the performance of the proposed control approach using MATLAB and Simulink environment. Simulation results show that this control approach is highly effective to track a given reference trajectory.
Aggarwal, Bharat B.; Sundaram, Chitra; Prasad, Seema; Kannappan, Ramaswamy
2010-01-01
Initially discovered in 1938 as a “fertility factor,” vitamin E now refers to eight different isoforms that belong to two categories, four saturated analogues (α, β, γ, and δ) called tocopherols and four unsaturated analogues referred to as tocotrienols. While the tocopherols have been investigated extensively, little is known about the tocotrienols. Very limited studies suggest that both the molecular and therapeutic targets of the tocotrienols are distinct from those of the tocopherols. For instance, suppression of inflammatory transcription factor NF-κB, which is closely linked to tumorigenesis and inhibition of HMG-CoA reductase, mammalian DNA polymerases and certain protein tyrosine kinases, is unique to the tocotrienols. This review examines in detail the molecular targets of the tocotrienols and their roles in cancer, bone resorption, diabetes, and cardiovascular and neurological diseases at both preclinical and clinical levels. As disappointment with the therapeutic value of the tocopherols grows, the potential of these novel vitamin E analogues awaits further investigation. PMID:20696139
... saturated fats. Vegetable sources of saturated fat include coconut and palm oils. When looking at a food ... saturated fats. Vegetable sources of saturated fat include coconut and palm oils. When looking at a food ...
Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma; Hendrikse, Jeroen; Groenendaal, Floris; van Bel, Frank; Benders, Manon Jnl; Petersen, Esben T
2017-03-01
Although near-infrared spectroscopy is increasingly being used to monitor cerebral oxygenation in neonates, it has a limited penetration depth. The T 2 -prepared Blood Imaging of Oxygen Saturation (T 2 -BIOS) magnetic resonance sequence provides an oxygen saturation estimate on a voxel-by-voxel basis, without needing a respiratory calibration experiment. In 15 neonates, oxygen saturation measured by T 2 -prepared blood imaging of oxygen saturation and near-infrared spectroscopy were compared. In addition, these measures were compared to cerebral blood flow and venous oxygen saturation in the sagittal sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy ( R 2 = 0.64, p < 0.001). Strong linear correlations were found between near-infrared spectroscopy oxygen saturation, and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus ( R 2 = 0.71, 0.50, 0.65; p < 0.01). The oxygen saturation obtained by T 2 -prepared blood imaging of oxygen saturation correlated with venous oxygen saturation in the sagittal sinus ( R 2 = 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T 2 -prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong correlations between the various methods work as a cross validation for near-infrared spectroscopy and T 2 -prepared blood imaging of oxygen saturation, confirming the validity of using of these techniques for determining cerebral oxygenation.
2014-01-01
Background Characterizing intra-urban variation in air quality is important for epidemiological investigation of health outcomes and disparities. To date, however, few studies have been designed to capture spatial variation during select hours of the day, or to examine the roles of meteorology and complex terrain in shaping intra-urban exposure gradients. Methods We designed a spatial saturation monitoring study to target local air pollution sources, and to understand the role of topography and temperature inversions on fine-scale pollution variation by systematically allocating sampling locations across gradients in key local emissions sources (vehicle traffic, industrial facilities) and topography (elevation) in the Pittsburgh area. Street-level integrated samples of fine particulate matter (PM2.5), black carbon (BC), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3) were collected during morning rush and probable inversion hours (6-11 AM), during summer and winter. We hypothesized that pollution concentrations would be: 1) higher under inversion conditions, 2) exacerbated in lower-elevation areas, and 3) vary by season. Results During July - August 2011 and January - March 2012, we observed wide spatial and seasonal variability in pollution concentrations, exceeding the range measured at regulatory monitors. We identified elevated concentrations of multiple pollutants at lower-elevation sites, and a positive association between inversion frequency and NO2 concentration. We examined temporal adjustment methods for deriving seasonal concentration estimates, and found that the appropriate reference temporal trend differs between pollutants. Conclusions Our time-stratified spatial saturation approach found some evidence for modification of inversion-concentration relationships by topography, and provided useful insights for refining and interpreting GIS-based pollution source indicators for Land Use Regression modeling. PMID:24735818
Soil Quality of Bauxite Mining Areas
NASA Astrophysics Data System (ADS)
Terezinha Gonçalves Bizuti, Denise; Dinarowski, Marcela; Casagrande, José Carlos; Silva, Luiz Gabriel; Soares, Marcio Roberto; Henrique Santin Brancalion, Pedro
2015-04-01
The study on soil quality index (SQI) aims to assess the current state of the soil after use and estimating its recovery through sustainable management practices This type of study is being used in this work in order to check the efficiency of forest recovery techniques in areas that have been deeply degraded by bauxite mining process, and compare them with the area of native forest, through the determination of SQI. Treatments were newly mined areas, areas undergoing restoration (topsoil use with planting of native forest species), areas in rehabilitation (employment of the green carpet with topsoil and planting of native forest species) and areas of native forests, with six repetitions, in areas of ALCOA, in the municipality of Poços de Caldas/MG. To this end, we used the additive pondered model, establishing three functions: Fertility, water movement and root development, based on chemical parameters (organic matter, base saturation, aluminum saturation and calcium content); physical (macroporosity, soil density and clay content); and microbiological testing (basal respiration by the emission of CO2 ). The SQIs obtained for each treatment was 41%, 56%, 63% and 71% for newly mined areas, native forest, areas in restoration and rehabilitation, respectively. The recovering technique that most approximates the degraded soil to the soil of reference is the restoration, where there was no statistically significant difference of areas restored with native forest. It was found that for the comparison of the studied areas must take into account the nutrient cycling, that disappear with plant removal in mining areas, once the soil of native forest features low fertility and high saturation by aluminum, also taking in account recovering time.
NASA Astrophysics Data System (ADS)
Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis
2018-02-01
The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).
NASA Astrophysics Data System (ADS)
Dittert, Nicolas; Henrich, Rüdiger
2000-04-01
Ultrastructure dissolution susceptibility of the planktic foraminifer Globigerina bulloides, carbonate ion content of the water column, calcium carbonate content of the sediment surface, and carbonate/carbon weight percentage ratio derived from sediment surface samples were investigated in order to reconstruct the position of the calcite saturation horizon, the sedimentary calcite lysocline, and the calcium carbonate compensation depth (CCD) in the modern South Atlantic Ocean. Carbonate ion data from the water column refer to the GEOSECS locations 48, 103, and 109 and calcium carbonate data come from 19 GeoB sediment surface samples of 4 transects into the Brazil, the Guinea, and the Cape Basins. We present a new (paleo-) oceanographic tool, namely the Globigerina bulloides dissolution index (BDX). Further, we give evidence (a) for progressive G. bulloides ultrastructural breakdown with increasing carbonate dissolution even above the lysocline; (b) for a sharp BDX increase at the sedimentary lysocline; and (c) for the total absence of this species at the CCD. BDX puts us in the position to distinguish the upper open ocean and the upwelling influenced continental margin above from the deep ocean below the sedimentary lysocline. Carbonate ion data from water column samples, calcite weight percentage data from surface sediment samples, and carbonate/carbon weight percentage ratio appear to be good proxies to confirm BDX. As shown by BDX both the calcite saturation horizon (in the water column) and the sedimentary lysocline (at the sediment-water interface) mark the boundary between the carbonate ion undersaturated and highly corrosive Antarctic Bottom Water and the carbonate ion saturated North Atlantic Deep Water (NADW) of the modern South Atlantic.
Tsui, C K; Boedo, J A; Stangeby, P C
2018-01-01
A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter l p , and the model is thus referred to as the "perimeter sheath expansion method." l p is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ∼ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ∼ 0 and for V = V f .
Increased Carbonic Anhydrase Activity is Associated with Sleep Apnea Severity and Related Hypoxemia.
Wang, Tengyu; Eskandari, Davoud; Zou, Ding; Grote, Ludger; Hedner, Jan
2015-07-01
The catalytic function of the enzyme carbonic anhydrase (CA) plays a fundamental role in carbon dioxide (CO2), proton (H(+)), and bicarbonate (HCO3(-)) homeostasis. Hypoxia and tissue acidosis have been proposed to increase physiological CA activity in various compartments of the body. We hypothesized that CA activity in blood is upregulated in patients with obstructive sleep apnea (OSA). Cross-sectional analysis of a sleep clinic cohort. Sleep laboratory at a university hospital. Seventy referred patients with suspected OSA (48 males, age 54 ± 13 y, apnea-hypopnea index (AHI) median [interquartile range] 21 [8-41] n/h). N/A. In-laboratory cardiorespiratory polygraphy was used to assess OSA. CA activity was determined by an in vitro assay that quantifies the pH change reflecting the conversion of CO2 and H2O to HCO3(-) and H(+). CA activity was positively associated with AHI and 4% oxygen desaturation index (ODI4) (Spearman correlation r = 0.44 and 0.47, both P < 0.001). The associations (CA activity versus logAHI and CA versus logODI4) were independent of sex, age, body mass index, presleep oxygen saturation, nocturnal oxygen saturation, hypertension status, and use of diuretic medication in two generalized linear models (P = 0.007 and 0.011, respectively). Sitting diastolic blood pressure was associated with CA activity after adjustment of sex, age, body mass index, mean oxygen saturation, and AHI (P = 0.046). Carbonic anhydrase (CA) activity increased with apnea-hypopnea index and related nocturnal hypoxemia measures in patients with obstructive sleep apnea (OSA). Altered CA activity may constitute a component that modulates respiratory control and hemodynamic regulation in patients with OSA. © 2015 Associated Professional Sleep Societies, LLC.
NASA Astrophysics Data System (ADS)
Tsui, C. K.; Boedo, J. A.; Stangeby, P. C.; TCV Team
2018-01-01
A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter lp, and the model is thus referred to as the "perimeter sheath expansion method." lp is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ˜ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ˜ 0 and for V = Vf.
The Controversial Role of Inter-diffusion in Glass Alteration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gin, Stephane; Neill, Lindsay; Fournier, M.
2016-11-15
Current kinetic models for nuclear waste glasses (e.g. GM2001, GRAAL) are based on a set of mechanisms that have been generally agreed upon within the international waste glass community. These mechanisms are: hydration of the glass, ion exchange reactions (the two processes are referred as inter-diffusion), hydrolysis of the silicate network, and condensation/precipitation of partly or completely hydrolyzed species that produces a porous and amorphous layer and crystalline phases on surface of the altered glass. Recently, a new idea with origins in the mineral dissolution community has been proposed that excludes inter-diffusion process as a potential rate-limiting mechanism. To understandmore » how the so-called interfacial dissolution/precipitation model can change the current understanding of glass behavior, a key experiment used to account for this model was replicated to further revisit the interpretation. This experiment was performed at 50°C, with SON68 glass, in static mode, deionized water and S/V ratio of 10 m-1 for 6 months. It turn out that glass alters in an intermediate kinetic regime between the forward and the residual rate. According to previous and new solid characterizations, it is concluded that neither a simple inter-diffusion model nor the interfacial dissolution precipitation model can account for the observed elemental profiles within the alteration layer. More generally, far and close-to-saturation conditions must be distinguished and literature provides evidences that inter-diffusion takes place in slightly acidic conditions and far from saturation. However, closer to saturation, when a sufficiently dense layer is formed, a new approach is proposed requiring a full description of chemical reactions taking place within the alteration layer and involving water molecules as it is thought that water accessibility to the pristine glass is the rate-limiting process.« less
Shmool, Jessie Lc; Michanowicz, Drew R; Cambal, Leah; Tunno, Brett; Howell, Jeffery; Gillooly, Sara; Roper, Courtney; Tripathy, Sheila; Chubb, Lauren G; Eisl, Holger M; Gorczynski, John E; Holguin, Fernando E; Shields, Kyra Naumoff; Clougherty, Jane E
2014-04-16
Characterizing intra-urban variation in air quality is important for epidemiological investigation of health outcomes and disparities. To date, however, few studies have been designed to capture spatial variation during select hours of the day, or to examine the roles of meteorology and complex terrain in shaping intra-urban exposure gradients. We designed a spatial saturation monitoring study to target local air pollution sources, and to understand the role of topography and temperature inversions on fine-scale pollution variation by systematically allocating sampling locations across gradients in key local emissions sources (vehicle traffic, industrial facilities) and topography (elevation) in the Pittsburgh area. Street-level integrated samples of fine particulate matter (PM2.5), black carbon (BC), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3) were collected during morning rush and probable inversion hours (6-11 AM), during summer and winter. We hypothesized that pollution concentrations would be: 1) higher under inversion conditions, 2) exacerbated in lower-elevation areas, and 3) vary by season. During July - August 2011 and January - March 2012, we observed wide spatial and seasonal variability in pollution concentrations, exceeding the range measured at regulatory monitors. We identified elevated concentrations of multiple pollutants at lower-elevation sites, and a positive association between inversion frequency and NO2 concentration. We examined temporal adjustment methods for deriving seasonal concentration estimates, and found that the appropriate reference temporal trend differs between pollutants. Our time-stratified spatial saturation approach found some evidence for modification of inversion-concentration relationships by topography, and provided useful insights for refining and interpreting GIS-based pollution source indicators for Land Use Regression modeling.
NASA Astrophysics Data System (ADS)
Ewerlöf, Maria; Larsson, Marcus; Salerud, E. Göran
2017-02-01
Hyperspectral imaging (HSI) can estimate the spatial distribution of skin blood oxygenation, using visible to near-infrared light. HSI oximeters often use a liquid-crystal tunable filter, an acousto-optic tunable filter or mechanically adjustable filter wheels, which has too long response/switching times to monitor tissue hemodynamics. This work aims to evaluate a multispectral snapshot imaging system to estimate skin blood volume and oxygen saturation with high temporal and spatial resolution. We use a snapshot imager, the xiSpec camera (MQ022HG-IM-SM4X4-VIS, XIMEA), having 16 wavelength-specific Fabry-Perot filters overlaid on the custom CMOS-chip. The spectral distribution of the bands is however substantially overlapping, which needs to be taken into account for an accurate analysis. An inverse Monte Carlo analysis is performed using a two-layered skin tissue model, defined by epidermal thickness, haemoglobin concentration and oxygen saturation, melanin concentration and spectrally dependent reduced-scattering coefficient, all parameters relevant for human skin. The analysis takes into account the spectral detector response of the xiSpec camera. At each spatial location in the field-of-view, we compare the simulated output to the detected diffusively backscattered spectra to find the best fit. The imager is evaluated for spatial and temporal variations during arterial and venous occlusion protocols applied to the forearm. Estimated blood volume changes and oxygenation maps at 512x272 pixels show values that are comparable to reference measurements performed in contact with the skin tissue. We conclude that the snapshot xiSpec camera, paired with an inverse Monte Carlo algorithm, permits us to use this sensor for spatial and temporal measurement of varying physiological parameters, such as skin tissue blood volume and oxygenation.
Color Change After Paramedical Pigmentation of the Nipple-Areola Complex.
Tomita, Shoichi; Mori, Katsuya; Miyawaki, Takeshi
2018-06-01
Reconstruction of the nipple-areola complex is the final process in breast reconstruction. Local flaps and paramedical pigmentation is one of the major procedures for this. However, fading after paramedical pigmentation leads to a color difference between the selected pigment and its color in the skin. The aim of this study is to make a proposition in color choice of paramedical pigmentation for nipple-areola complex. Our research focused on investigating the color changes over time after unilateral nipple-areola complex reconstruction using paramedical pigmentation in 25 patients to propose suitable color selections. We measured the color by spectrometer and conducted comparisons using the hue, saturation, and value (HSV) color space and the color space defined by the Commission International de L'eclairage based on one channel for luminance (lightness) (L) and two color channels (a and b) (L*a*b*). A comparison of the hue, value, and saturation of the reconstructed areola compared to the normal areolae was conducted using HSV color space; the value and saturation were satisfactory after 3 months and beyond, but the reconstructed areola tended to have stronger red hues. The color difference (ΔE 00 ) calculated in L*a*b* color space showed slow fading after the scab was peeled off. This result indicates that a color with less redness and more yellowness, particularly 4-5 degrees of yellowness on the color wheel, than the normal side is the most appropriate color selection for this technique. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Are faults preferential flow paths through semiarid and arid vadose zones?
NASA Astrophysics Data System (ADS)
Sigda, John M.; Wilson, John L.
2003-08-01
Numerous faults crosscut the poorly lithified, basin-fill sands found in New Mexico's Rio Grande rift and in other extensional regimes. The deformational processes that created these faults sharply reduced both fault porosity and fault saturated hydraulic conductivity by altering grains and pores, particularly in structures referred to as deformation bands. The resulting pore distribution changes, which create barriers to saturated flow, should enhance fault unsaturated flow relative to parent sand under the relatively dry conditions of the semiarid southwest. We report the first measurements of unsaturated hydraulic properties for undisturbed fault materials, using samples from a small-displacement normal fault and parent sands in the Bosque del Apache Wildlife Refuge, central New Mexico. Fault samples were taken from a narrow zone of deformation bands. The unsaturated flow apparatus (UFA) centrifuge system was used to measure both relative permeability and moisture retention curves. We compared these relations and fitted hydraulic conductivity-matric potential models to test whether the fault has significantly different unsaturated hydraulic properties than its parent sand. Saturated conductivity is 3 orders of magnitude less in the fault than the undeformed sand. As matric potential decreases from 0 to -200 cm, unsaturated conductivity decreases roughly 1 order of magnitude in the fault but 5-6 orders of magnitude in undeformed sands. Fault conductivity is greater by 2-6 orders of magnitude at matric potentials between -200 and -1000 cm, which are typical potentials for semiarid and arid vadose zones. Fault deformation bands have much higher air-entry matric potential values than parent sands and remain close to saturation well after the parent sands have begun to approach residual moisture content. Under steady state, one-dimensional, gravity-driven flow conditions, moisture transport and solute advection is 102-106 times larger in the fault material than parent sands. Faults are sufficiently conductive to hasten the downward movement of water and solutes through vadose-zone sands under semiarid and arid conditions like those in the Rio Grande rift, thereby potentially enhancing recharge, contaminant migration, and diagenesis.
What about N? A methodological study of sample-size reporting in focus group studies.
Carlsen, Benedicte; Glenton, Claire
2011-03-11
Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96). Thirty seven (17%) studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Based on these findings we suggest that journals adopt more stringent requirements for focus group method reporting. The often poor and inconsistent reporting seen in these studies may also reflect the lack of clear, evidence-based guidance about deciding on sample size. More empirical research is needed to develop focus group methodology.
Oxygen isotopes as a tool to quantify reservoir-scale CO2 pore-space saturation
NASA Astrophysics Data System (ADS)
Serno, Sascha; Flude, Stephanie; Johnson, Gareth; Mayer, Bernard; Boyce, Adrian; Karolyte, Ruta; Haszeldine, Stuart; Gilfillan, Stuart
2017-04-01
Structural and residual trapping of carbon dioxide (CO2) are two key mechanisms of secure CO2 storage, an essential component of Carbon Capture and Storage technology [1]. Estimating the amount of CO2 that is trapped by these two mechanisms is a vital requirement for accurately assessing the secure CO2 storage capacity of a formation, but remains a key challenge. Recent field [2,3] and laboratory experiment studies [4] have shown that simple and relatively inexpensive measurements of oxygen isotope ratios in both the injected CO2 and produced water can provide an assessment of the amount of CO2 that is stored by these processes. These oxygen isotope assessments on samples obtained from observation wells provide results which are comparable to other geophysical techniques. In this presentation, based on the first comprehensive review of oxygen isotope ratios measured in reservoir waters and CO2 from global CO2 injection projects, we will outline the advantages and potential limitations of using oxygen isotopes to quantify CO2 pore-space saturation. We will further summarise the currently available information on the oxygen isotope composition of captured CO2. Finally, we identify the potential issues in the use of the oxygen isotope shifts in the reservoir water from baseline conditions to estimate accurate saturations of the pore space with CO2, and suggest how these issues can be reduced or avoided to provide reliable CO2 pore-space saturations on a reservoir scale in future field experiments. References [1] Scott et al., (2013) Nature Climate Change, Vol. 3, 105-111 doi:10.1038/nclimate1695 [2] Johnson et al., (2011) Chemical Geology, Vol. 283, 185-193 http://dx.doi.org/10.1016/j.ijggc.2016.06.019 [3] Serno et al., (2016) IJGGC, Vol. 52, 73-83 http://dx.doi.org/10.1016/j.ijggc.2016.06.019 [4] Johnson et al., (2011) Applied Geochemistry, Vol. 26 (7) 1184-1191 http://dx.doi.org/10.1016/j.apgeochem.2011.04.007
Quantifying moisture transport in cementitious materials using neutron radiography
NASA Astrophysics Data System (ADS)
Lucero, Catherine L.
A portion of the concrete pavements in the US have recently been observed to have premature joint deterioration. This damage is caused in part by the ingress of fluids, like water, salt water, or deicing salts. The ingress of these fluids can damage concrete when they freeze and expand or can react with the cementitious matrix causing damage. To determine the quality of concrete for assessing potential service life it is often necessary to measure the rate of fluid ingress, or sorptivity. Neutron imaging is a powerful method for quantifying fluid penetration since it can describe where water has penetrated, how quickly it has penetrated and the volume of water in the concrete or mortar. Neutrons are sensitive to light atoms such as hydrogen and thus clearly detect water at high spatial and temporal resolution. It can be used to detect small changes in moisture content and is ideal for monitoring wetting and drying in mortar exposed to various fluids. This study aimed at developing a method to accurately estimate moisture content in mortar. The common practice is to image the material dry as a reference before exposing to fluid and normalizing subsequent images to the reference. The volume of water can then be computed using the Beer-Lambert law. This method can be limiting because it requires exact image alignment between the reference image and all subsequent images. A model of neutron attenuation in a multi-phase cementitious composite was developed to be used in cases where a reference image is not available. The attenuation coefficients for water, un-hydrated cement, and sand were directly calculated from the neutron images. The attenuation coefficient for the hydration products was then back-calculated. The model can estimate the degree of saturation in a mortar with known mixture proportions without using a reference image for calculation. Absorption in mortars exposed to various fluids (i.e., deionized water and calcium chloride solutions) were investigated. It has been found through this study that small pores, namely voids created by chemical shrinkage, gel pores, and capillary pores, ranging from 0.5 nm to 50 microm, fill quickly through capillary action. However, large entrapped and entrained air voids ranging from 0.05 to 1.25 mm remain empty during the initial filling process. In mortar exposed to calcium chloride solution, a decrease in sorptivity was observed due to an increase in viscosity and surface tension of the solution as proposed by Spragg et al 2011. This work however also noted a decrease in the rate of absorption due to a reaction between the salt and matrix which results in the filling of the pores in the concrete. The results from neutron imaging can help in the interpretation of standard absorption tests. ASTM C1585 test results can be further analyzed in several ways that could give an accurate indication of the durability of the concrete. Results can be reported in depth of penetration versus the square root of time rather than mm3 of fluid per mm2 of exposed surface area. Since a known fraction of pores are initially filling before reaching the edge of the sample, the actual depth of penetration can be calculated. This work is compared with an 'intrinsic sorptivity' that can be used to interpret mass measurements. Furthermore, the influence of shrinkage reducing admixtures (SRAs) on drying was studied. Neutron radiographs showed that systems saturated in water remain "wetter" than systems saturated in 5% SRA solution. The SRA in the system reduces the moisture diffusion coefficient due an increase in viscosity and decrease in surface tension. Neutron radiography provided spatial information of the drying front that cannot be achieved using other methods.
A multislice gradient echo pulse sequence for CEST imaging.
Dixon, W Thomas; Hancu, Ileana; Ratnakar, S James; Sherry, A Dean; Lenkinski, Robert E; Alsop, David C
2010-01-01
Chemical exchange-dependent saturation transfer and paramagnetic chemical exchange-dependent saturation transfer are agent-mediated contrast mechanisms that depend on saturating spins at the resonant frequency of the exchangeable protons on the agent, thereby indirectly saturating the bulk water. In general, longer saturating pulses produce stronger chemical and paramagnetic exchange-dependent saturation transfer effects, with returns diminishing for pulses longer than T1. This could make imaging slow, so one approach to chemical exchange-dependent saturation transfer imaging has been to follow a long, frequency-selective saturation period by a fast imaging method. A new approach is to insert a short frequency-selective saturation pulse before each spatially selective observation pulse in a standard, two-dimensional, gradient-echo pulse sequence. Being much less than T1 apart, the saturation pulses have a cumulative effect. Interleaved, multislice imaging is straightforward. Observation pulses directed at one slice did not produce observable, unintended chemical exchange-dependent saturation transfer effects in another slice. Pulse repetition time and signal-to noise ratio increase in the normal way as more slices are imaged simultaneously. Copyright (c) 2009 Wiley-Liss, Inc.
Campbell, Andrew; Minniti, Caterina P.; Nouraie, Mehdi; Arteta, Manuel; Rana, Sohail; Onyekwere, Onyinye; Sable, Craig; Ensing, Gregory; Dham, Niti; Luchtman-Jones, Lori; Kato, Gregory J.; Gladwin, Mark T.; Castro, Oswaldo L.; Gordeuk, Victor R.
2009-01-01
Summary Low steady state haemoglobin oxygen saturation in patients with sickle cell anaemia has been associated with the degree of anaemia and haemolysis. How much pulmonary dysfunction contributes to low saturation is not clear. In a prospective study of children and adolescents with sickle cell disease aged 3–20 years at steady state and matched controls, 52% of 391 patients versus 24% of 63 controls had steady state oxygen saturation <99% (P < 0·0001), 9% of patients versus no controls had saturation <95% (P = 0·008) and 8% of patients versus no controls had exercise-induced reduction in saturation ≥3%. Decreasing haemoglobin concentration (P ≤ 0·001) and increasing haemolysis (P ≤ 0·003) but not pulmonary function tests were independent predictors of both lower steady-state saturation and exercise-induced reduction in saturation. Neither history of stroke nor history of acute chest syndrome was significantly associated with lower steady-state oxygen saturation or exercise-induced reduction in saturation. Tricuspid regurgitation velocity was higher in patients with lower steady state haemoglobin oxygen saturation (P = 0·003) and with greater decline in oxygen saturation during the six-minute walk (P = 0·022). In conclusion, lower haemoglobin oxygen saturation is independently associated with increasing degrees of anaemia and haemolysis but not pulmonary function abnormalities among children and adolescents with sickle cell disease. PMID:19694721
NASA Astrophysics Data System (ADS)
Vedanti, Nimisha; Malkoti, Ajay; Pandey, O. P.; Shrivastava, J. P.
2018-03-01
Petrophysical properties and ultrasonic P- and S-wave attenuation measurements on 35 Deccan basalt core specimens, recovered from Killari borehole site in western India, provide unique reference data-sets for a lesser studied Deccan Volcanic Province. These samples represent 338-m-thick basaltic column, consisting four lava flows each of Ambenali and Poladpur Formations, belonging to Wai Subgroup of the Deccan volcanic sequence. These basalt samples are found to be iron-rich (average FeOT: 13.4 wt%), but relatively poor in silica content (average SiO2: 47.8 wt%). The saturated massive basalt cores are characterized by a mean density of 2.91 g/cm3 (range 2.80-3.01 g/cm3) and mean P- and S-wave velocities of 5.89 km/s (range 5.01-6.50 km/s) and 3.43 km/s (range 2.84-3.69 km/s), respectively. In comparison, saturated vesicular basalt cores show a wide range in density (2.40-2.79 g/cm3) as well as P-wave (3.28-4.78 km/s) and S-wave (1.70-2.95 km/s) velocities. Based on the present study, the Deccan volcanic sequence can be assigned a weighted mean density of 2.74 g/cm3 and a low V p and V s of 5.00 and 3.00 km/s, respectively. Such low velocities in Deccan basalts can be attributed mainly to the presence of fine-grained glassy material, high iron contents, and hydrothermally altered secondary mineral products, besides higher porosity in vesicular samples. The measured Q values in saturated massive basalt cores vary enormously (Q p: 33-1960 and Q s: 35-506), while saturated vesicular basalt samples exhibit somewhat lesser variation in Q p (6-46) as well as Q s (5-49). In general, high-porosity rocks exhibit high attenuation, but we observed the high value of attenuation in some of the massive basalt core samples also. In such cases, energy loss is mainly due to the presence of fine-grained glassy material as well as secondary alteration products like chlorophaeite, that could contribute to intrinsic attenuation. Dominance of weekly bound secondary minerals might also be responsible for the generation of microcracks, which may generate squirt flow in saturated samples. Hence, we argue that the Deccan basalts attenuate seismic energy significantly, where its composition plays a major role.
Review of the role of dielectric anisotropy in Dyakonov surface-wave propagation
NASA Astrophysics Data System (ADS)
Nelatury, Sudarshan R., II; Polo, John A., Jr.; Lakhtakia, Akhlesh
2008-08-01
Surface waves (SWs) are localized waves that travel along the planar interface between two different mediums when certain dispersion relations are satisfied. If both mediums have purely dielectric constitutive properties, the characteristics of SW propagation are determined by the anisotropy of both mediums. Surface waves are then called Dyakonov SWs (DSWs), after Dyakonov who theoretically established the possibility of SW propagation at the planar interface of an isotropic dielectric and a positive uniaxial dielectric. Since then, DSW propagation guided by interfaces between a variety of dielectrics has been studied. With an isotropic dielectric on one side, the dielectric on the other side of the interface can be not only positive uniaxial but also biaxial. DSW propagation can also occur along an interface between two uniaxial or biaxial dielectrics that are twisted about a common axis with respect to each other but are otherwise identical. Recently, DSW propagation has been studied taking (i) uniaxial dielectrics such as calomel and dioptase crystals; (ii) biaxial dielectrics such as hemimorphite, crocoite, tellurite, witherite, and cerussite; and (iii) electro-optic materials such as potassium niobate. With materials that are significantly anisotropic, the angular regime of directions for DSW propagation turns out to be narrow. In the case of naturally occurring crystals, one has to accept the narrow angular existence domain (AED). However, exploiting the Pockels effect not only facilitates dynamic electrical control of DSW propagation, but also widens the AED for DSW propagation.
Association of physical examination with pulmonary artery catheter parameters in acute lung injury.
Grissom, Colin K; Morris, Alan H; Lanken, Paul N; Ancukiewicz, Marek; Orme, James F; Schoenfeld, David A; Thompson, B Taylor
2009-10-01
To correlate physical examination findings, central venous pressure, fluid output, and central venous oxygen saturation with pulmonary artery catheter parameters. Retrospective study. Data from the multicenter Fluid and Catheter Treatment Trial of the National Institutes of Health Acute Respiratory Distress Syndrome Network. Five hundred thirteen patients with acute lung injury randomized to treatment with a pulmonary artery catheter. Correlation of physical examination findings (capillary refill time >2 secs, knee mottling, or cool extremities), central venous pressure, fluid output, and central venous oxygen saturation with parameters from a pulmonary artery catheter. We determined association of baseline physical examination findings and on-study parameters of central venous pressure and central venous oxygen saturation with cardiac index <2.5 L/min/m2 and mixed venous oxygen saturation <60%. We determined correlation of baseline central venous oxygen saturation and mixed venous oxygen saturation and predictive value of a low central venous oxygen saturation for a low mixed venous oxygen saturation. Prevalence of cardiac index <2.5 and mixed venous oxygen saturation <60% was 8.1% and 15.5%, respectively. Baseline presence of all three physical examination findings had low sensitivity (12% and 8%), high specificity (98% and 99%), low positive predictive value (40% and 56%), but high negative predictive value (93% and 86%) for cardiac index <2.5 and mixed venous oxygen saturation <60%, respectively. Central venous oxygen saturation <70% predicted a mixed venous oxygen saturation <60% with a sensitivity 84%,specificity 70%, positive predictive value 31%, and negative predictive value of 96%. Low cardiac index correlated with cool extremities, high central venous pressure, and low 24-hr fluid output; and low mixed venous oxygen saturation correlated with knee mottling and high central venous pressure, but these correlations were not found to be clinically useful. In this subset of patients with acute lung injury, there is a high prior probability that cardiac index and mixed venous oxygen saturation are normal and physical examination findings of ineffective circulation are not useful for predicting low cardiac index or mixed venous oxygen saturation. Central venous oxygen saturation <70% does not accurately predict mixed venous oxygen saturation <60%, but a central venous oxygen saturation >or=70% may be useful to exclude mixed venous oxygen saturation <60%.
Kroll, Tina; Elmenhorst, David; Matusch, Andreas; Wedekind, Franziska; Weisshaupt, Angela; Beer, Simone; Bauer, Andreas
2013-08-01
While the selective 5-hydroxytryptamine type 2a receptor (5-HT2AR) radiotracer [18F]altanserin is well established in humans, the present study evaluated its suitability for quantifying cerebral 5-HT2ARs with positron emission tomography (PET) in albino rats. Ten Sprague Dawley rats underwent 180 min PET scans with arterial blood sampling. Reference tissue methods were evaluated on the basis of invasive kinetic models with metabolite-corrected arterial input functions. In vivo 5-HT2AR quantification with PET was validated by in vitro autoradiographic saturation experiments in the same animals. Overall brain uptake of [18F]altanserin was reliably quantified by invasive and non-invasive models with the cerebellum as reference region shown by linear correlation of outcome parameters. Unlike in humans, no lipophilic metabolites occurred so that brain activity derived solely from parent compound. PET data correlated very well with in vitro autoradiographic data of the same animals. [18F]Altanserin PET is a reliable tool for in vivo quantification of 5-HT2AR availability in albino rats. Models based on both blood input and reference tissue describe radiotracer kinetics adequately. Low cerebral tracer uptake might, however, cause restrictions in experimental usage.
Control of a HexaPOD treatment couch for robot-assisted radiotherapy.
Hermann, Christian; Ma, Lei; Wilbert, Jürgen; Baier, Kurt; Schilling, Klaus
2012-10-01
Moving tumors, for example in the vicinity of the lungs, pose a challenging problem in radiotherapy, as healthy tissue should not be irradiated. Apart from gating approaches, one standard method is to irradiate the complete volume within which a tumor moves plus a safety margin containing a considerable volume of healthy tissue. This work deals with a system for tumor motion compensation using the HexaPOD® robotic treatment couch (Medical Intelligence GmbH, Schwabmünchen, Germany). The HexaPOD, carrying the patient during treatment, is instructed to perform translational movements such that the tumor motion, from the beams-eye view of the linear accelerator, is eliminated. The dynamics of the HexaPOD are characterized by time delays, saturations, and other non-linearities that make the design of control a challenging task. The focus of this work lies on two control methods for the HexaPOD that can be used for reference tracking. The first method uses a model predictive controller based on a model gained through system identification methods, and the second method uses a position control scheme useful for reference tracking. We compared the tracking performance of both methods in various experiments with real hardware using ideal reference trajectories, prerecorded patient trajectories, and human volunteers whose breathing motion was compensated by the system.
Bjerve, K S
1984-01-01
The specificity of the L-serine base-exchange enzyme towards the fatty acid composition of the phospholipid substrate was investigated with a rat liver microsomal fraction. The relative rates of L-serine incorporation into saturated-hexaenoic, saturated-pentaenoic, saturated-tetraenoic, saturated-trienoic, dienoic-dienoic, monoenoic-dienoic, saturated-dienoic and saturated-monoenoic + saturated-saturated phosphatidylserine molecular species were 42, 5, 23, 4, 5, 4, 5 and 11% respectively. This is similar to, but not identical with, the relative mass abundance of these molecular species in total liver cell phosphatidylserines. The results indicate that the substrate-specificity of the L-serine base-exchange enzyme can at least in part explain the observed fatty acid composition of rat liver phosphatidylserines. PMID:6430274
The viscosity of the refrigerant 1,1-difluoroethane along the saturation line
NASA Astrophysics Data System (ADS)
van der Gulik, P. S.
1993-07-01
The viscosity coefficient of the refrigerant R152a (1,1-difluoroethane) has been measured along the saturation line both in the saturated liquid and in the saturated vapor. The data have been obtained every 10 K from 243 up to 393 K by means of a vibrating-wire viscometer using the free damped oscillation method. The density along the saturation line was calculated from the equation of state given by Tamatsu et al. with application of the saturated vapor-pressure correlation given by Higashi et al. An interesting result is that in the neighborhood of the critical point, the kinematic viscosity of the saturated liquid seems to coincide with that of the saturated vapor. The results for the saturated liquid are in satisfying agreement with those of Kumagai and Takahashi and of Phillips and Murphy. A comparison of the saturatedvaport data with the unsaturated-vapor data of Takahashi et al. shows some discrepancies.
A New Composite Electrode Applied for Studying the Electrochemistry of Insoluble Particles: α-HgS.
Yang, Minjun; Compton, Richard G
2018-05-22
The redox chemistry of solid α-HgS particles is revealed using a carbon/PVDF composite containing α-HgS, carbon black, polyvinylidene fluoride (PVDF). The electrochemical behaviour of the carbon/PVDF composite is first characterised with three water insoluble organic solids. Then the reduction of solid α-HgS particles is investigated and found to occur at a high negative potential, -1.82 V versus saturated mercury sulphate reference electrode, to form metallic mercury and sulphide ions. The subsequent oxidation of metallic mercury and sulphide occurs at +0.24 and -0.49 V versus MSE respectively. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Iodine-stabilized single-frequency green InGaN diode laser.
Chen, Yi-Hsi; Lin, Wei-Chen; Shy, Jow-Tsong; Chui, Hsiang-Chen
2018-01-01
A 520-nm InGaN diode laser can emit a milliwatt-level, single-frequency laser beam when the applied current slightly exceeds the lasing threshold. The laser frequency was less sensitive to diode temperature and could be finely tuned by adjusting the applied current. Laser frequency was stabilized onto a hyperfine component in an iodine transition through the saturated absorption spectroscopy. The uncertainty of frequency stabilization was approximately 8×10 -9 at a 10-s integration time. This compact laser system can replace the conventional green diode-pumped solid-state laser and applied as a frequency reference. A single longitudinal mode operational region with diode temperature, current, and output power was investigated.
Extended Fenske-Hall LCAO MO calculations of core-level shifts in solid P compounds
NASA Astrophysics Data System (ADS)
Franke, R.; Chassé, T.; Reinhold, J.; Streubel, P.; Szargan, R.
1997-08-01
Extended Fenske-Hall LCAO-MO ΔSCF calculations on solids modelled as H-pseudoatom saturated clusters are reported. The computational results verify the experimentally obtained initial-state (effective atomic charges, Madelung potential) and relaxation-energy contributions to the XPS phosphorus core-level binding energy shifts measured in Na 3PO 3S, Na 3PO 4, Na 2PO 3F and NH 4PF 6 in reference to red phosphorus. It is shown that the different initial-state contributions observed in the studied phosphates are determined by local and nonlocal terms while the relaxation-energy contributions are mainly dependent on the nature of the nearest neighbors of the phosphorus atom.
Head-target tracking control of well drilling
NASA Astrophysics Data System (ADS)
Agzamov, Z. V.
2018-05-01
The method of directional drilling trajectory control for oil and gas wells using predictive models is considered in the paper. The developed method does not apply optimization and therefore there is no need for the high-performance computing. Nevertheless, it allows following the well-plan with high precision taking into account process input saturation. Controller output is calculated both from the present target reference point of the well-plan and from well trajectory prediction with using the analytical model. This method allows following a well-plan not only on angular, but also on the Cartesian coordinates. Simulation of the control system has confirmed the high precision and operation performance with a wide range of random disturbance action.
Phospholipid component volumes: determination and application to bilayer structure calculations.
Armen, R S; Uitto, O D; Feller, S E
1998-08-01
We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments.
Phospholipid component volumes: determination and application to bilayer structure calculations.
Armen, R S; Uitto, O D; Feller, S E
1998-01-01
We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments. PMID:9675175
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sow, P. L. T.; Mejri, S.; Tokunaga, S. K.
2014-06-30
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-μm to the secondary frequency standard of this spectral region, a CO{sub 2} laser stabilized on a saturated absorption line of OsO{sub 4}. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH{sub 3} and methyltrioxorhenium, two species of interest for applications in precision measurements.
NASA Astrophysics Data System (ADS)
Kirillovich, Ivan; Gubenko, Vladimir; Pavelyev, Alexander
Internal gravity waves (IGWs) affect the structure and circulation of the Earth’s atmosphere by transporting energy and momentum upward from lower atmosphere. Observations of the temperature and wind velocity fluctuations in the middle atmosphere have shown that wave amplitudes grow with increasing altitude, however, no quickly enough in order to correspond to amplitude growth due to exponential decrease of density in the absence of energy dissipation. The theory of saturated IGWs explains such rate of the wave amplitude growth in the following way: any wave amplitude in excess of the threshold value will lead to instability and the production of turbulence that acts to prevent further growth of the wave amplitude. The mechanisms that contribute most to the dissipation and saturation of the dominant IGW motions in the atmosphere are thought to be the dynamical (shear) and convective instability. For high-frequency waves, the threshold amplitude required to achieve shear instability is virtually identical to that required for convective instability. But for low-frequency IGWs, the shear instability threshold falls well below that necessary for convective instability. The knowledge of actual and threshold wave amplitudes is important when the effect of IGWs on the background atmosphere is to be assessed. The internal wave saturation assumption plays the key role for radio occultation (RO) investigations of IGWs in planetary atmospheres [Gubenko et al., 2008, 2011, 2012], therefore a radiosonde study of wave saturation processes in the Earth’s atmosphere is actual task. The results of determination of the actual and threshold amplitudes, saturation degree and other characteristics for identified IGWs in the Earth’s atmosphere found from high-resolution radiosonde measurements SPARC (http://www.sparc.sunysb.edu/) of horizontal wind and temperature are presented. The usefulness of these observations in conjunction with RO studies of IGWs is discussed. The work was carried out under partial support of the RFBR grant 13-02-00526-a and Program 22 of the RAS Presidium. References. Gubenko V.N., Pavelyev A.G., Andreev V.E. Determination of the intrinsic frequency and other wave parameters from a single vertical temperature or density profile measurement // J. Geophys. Res. 2008. V. 113. No.D08109, doi:10.1029/2007JD008920. Gubenko V.N., Pavelyev A.G., Salimzyanov R.R., Pavelyev A.A. Reconstruction of internal gravity wave parameters from radio occultation retrievals of vertical temperature profiles in the Earth’s atmosphere // Atmos. Meas. Tech. 2011. V. 4. No.10. P. 2153-2162, doi:10.5194/amt-4-2153-2011. Gubenko V.N., Pavelyev A.G., Salimzyanov R.R., Andreev V.E. A method for determination of internal gravity wave parameters from a vertical temperature or density profile measurement in the Earth’s atmosphere // Cosmic Res. 2012. V. 50. No.1. P. 21-31, doi: 10.1134/S0010952512010029.
Estimation of saturated pixel values in digital color imaging
Zhang, Xuemei; Brainard, David H.
2007-01-01
Pixel saturation, where the incident light at a pixel causes one of the color channels of the camera sensor to respond at its maximum value, can produce undesirable artifacts in digital color images. We present a Bayesian algorithm that estimates what the saturated channel's value would have been in the absence of saturation. The algorithm uses the non-saturated responses from the other color channels, together with a multivariate Normal prior that captures the correlation in response across color channels. The appropriate parameters for the prior may be estimated directly from the image data, since most image pixels are not saturated. Given the prior, the responses of the non-saturated channels, and the fact that the true response of the saturated channel is known to be greater than the saturation level, the algorithm returns the optimal expected mean square estimate for the true response. Extensions of the algorithm to the case where more than one channel is saturated are also discussed. Both simulations and examples with real images are presented to show that the algorithm is effective. PMID:15603065
Discharge and aftercare in chronic lung disease of the newborn.
Primhak, R A
2003-04-01
This article deals with the discharge planning and continuing care of babies with chronic lung disease of the newborn (CLD), especially those with a continuing oxygen requirement, with some reference to longer term outcome. The pattern of CLD has changed since early descriptions, and the most useful definition for persisting morbidity in a baby with lung disease is a continuing oxygen requirement beyond 36 weeks post-menstrual age. Long-term oxygen therapy to maintain oxygen saturation at a mean of 95% or more and prevent levels below 90% is the cornerstone of management, and with adequate oxygen therapy the excess mortality previously reported in CLD can largely be avoided. Care must be given to the method of assessing oxygen saturation: overnight monitoring using appropriate recording devices is recommended. Exposure to respiratory viruses should be minimized where possible. Metabolic requirements are increased, but if efforts are made to maintain adequate energy input the long-term outlook for catch-up growth in height is good. Respiratory morbidity is increased in early life, but this improves in later childhood, along with lung function and exercise tolerance. Although respiratory symptoms should be treated as they arise, there is no evidence for long-term benefit from any pharmacological intervention in CLD.
Cummings, James J; Lakshminrusimha, Satyan
2017-04-01
A collaboration of comparative effectiveness research trials of pulse oximeter saturation (SpO2) targeting in extremely low-gestational-age neonates have begun to report their aggregate results. We examine the results of those trials, collectively referred to as the Neonatal Oxygenation Prospective Meta-analysis or NeOProM. We also discuss the uncertainties that remain and the clinical challenges that lie ahead. The primary outcome from NeOProM was a composite of death or disability at 18-24 months corrected age. In 2016 the last of these reports was published. Although there were no differences in the primary outcome overall, analyses of secondary outcomes and data subsets following a pulse oximeter revision show significant treatment differences between targeting a lower compared with a higher SpO2. NeOProM represents the largest collaborative clinical research study of SpO2 targets in extremely low-gestational-age neonates. Although aggregate results give us some insight into the feasibility and efficacy of SpO2 targeting in this population, many questions remain. A patient-level analysis, tracking individual outcomes based on actual SpO2 experienced, may shed some light on these questions. However, finding a single optimal SpO2 range seems unlikely.
NASA Astrophysics Data System (ADS)
Lee, Jae-Hyeok; Choe, Jinhyeok; Hwang, Shinwon; Kim, Sang-Koog
2017-08-01
We studied the mechanism of magnetization reversals and coercivity enhancements in three-dimensional (3D) granular Nd-Fe-B permanent magnets using finite-element micromagnetic simulations. The magnetization reversals in the hard magnets consisting of hard-phase grains separated by relatively soft-phase grain boundaries were analyzed with reference to the simulation results for the magnetic field-dependent distributions of the local magnetizations. The saturation magnetization of the grain-boundary phase plays a crucial role in the transition between nucleation- and domain-wall-propagation-controlled reversal processes. The smaller the saturation magnetization of the grain-boundary phase is, the more preferable is the nucleation-controlled process, which results in a larger coercivity. The exchange stiffness of the grain-boundary phase determines the preferred paths of domain-wall propagations, whether inward into grains or along the grain boundaries for relatively small and large exchange stiffness, respectively. However, the exchange stiffness of the grain-boundary phase alone does not significantly contribute to coercivity enhancement in cases where the size of hard-phase grains is much greater than the exchange length. This work paves the way for the design of high-performance hard magnets of large coercivity and maximum-energy-product values.
NASA Astrophysics Data System (ADS)
Podestà, M.; Gorelenkova, M.; Gorelenkov, N. N.; White, R. B.
2017-09-01
Alfvénic instabilities (AEs) are well known as a potential cause of enhanced fast ion transport in fusion devices. Given a specific plasma scenario, quantitative predictions of (i) expected unstable AE spectrum and (ii) resulting fast ion transport are required to prevent or mitigate the AE-induced degradation in fusion performance. Reduced models are becoming an attractive tool to analyze existing scenarios as well as for scenario prediction in time-dependent simulations. In this work, a neutral beam heated NSTX discharge is used as reference to illustrate the potential of a reduced fast ion transport model, known as kick model, that has been recently implemented for interpretive and predictive analysis within the framework of the time-dependent tokamak transport code TRANSP. Predictive capabilities for AE stability and saturation amplitude are first assessed, based on given thermal plasma profiles only. Predictions are then compared to experimental results, and the interpretive capabilities of the model further discussed. Overall, the reduced model captures the main properties of the instabilities and associated effects on the fast ion population. Additional information from the actual experiment enables further tuning of the model’s parameters to achieve a close match with measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podestà, M.; Gorelenkova, M.; Gorelenkov, N. N.
Alfvénic instabilities (AEs) are well known as a potential cause of enhanced fast ion transport in fusion devices. Given a specific plasma scenario, quantitative predictions of (i) expected unstable AE spectrum and (ii) resulting fast ion transport are required to prevent or mitigate the AE-induced degradation in fusion performance. Reduced models are becoming an attractive tool to analyze existing scenarios as well as for scenario prediction in time-dependent simulations. Here, in this work, a neutral beam heated NSTX discharge is used as reference to illustrate the potential of a reduced fast ion transport model, known as kick model, that hasmore » been recently implemented for interpretive and predictive analysis within the framework of the time-dependent tokamak transport code TRANSP. Predictive capabilities for AE stability and saturation amplitude are first assessed, based on given thermal plasma profiles only. Predictions are then compared to experimental results, and the interpretive capabilities of the model further discussed. Overall, the reduced model captures the main properties of the instabilities and associated effects on the fast ion population. Finally, additional information from the actual experiment enables further tuning of the model's parameters to achieve a close match with measurements.« less
Full Coupling Between the Atmosphere, Surface, and Subsurface for Integrated Hydrologic Simulation
NASA Astrophysics Data System (ADS)
Davison, Jason Hamilton; Hwang, Hyoun-Tae; Sudicky, Edward A.; Mallia, Derek V.; Lin, John C.
2018-01-01
An ever increasing community of earth system modelers is incorporating new physical processes into numerical models. This trend is facilitated by advancements in computational resources, improvements in simulation skill, and the desire to build numerical simulators that represent the water cycle with greater fidelity. In this quest to develop a state-of-the-art water cycle model, we coupled HydroGeoSphere (HGS), a 3-D control-volume finite element surface and variably saturated subsurface flow model that includes evapotranspiration processes, to the Weather Research and Forecasting (WRF) Model, a 3-D finite difference nonhydrostatic mesoscale atmospheric model. The two-way coupled model, referred to as HGS-WRF, exchanges the actual evapotranspiration fluxes and soil saturations calculated by HGS to WRF; conversely, the potential evapotranspiration and precipitation fluxes from WRF are passed to HGS. The flexible HGS-WRF coupling method allows for unique meshes used by each model, while maintaining mass and energy conservation between the domains. Furthermore, the HGS-WRF coupling implements a subtime stepping algorithm to minimize computational expense. As a demonstration of HGS-WRF's capabilities, we applied it to the California Basin and found a strong connection between the depth to the groundwater table and the latent heat fluxes across the land surface.
NASA Astrophysics Data System (ADS)
Gardiner, B. L.; Thomson, D. J.
2006-12-01
Starting with the designs of earlier solar radio telescopes, particularly the one at Bell Labs, Murray Hill, we have built a new instrument. The major differences between this telescope and its predecessors are that it has: 1) parallel low and high gain channels for both polarizations; 2) four additional channels for active interference cancellation; and 3) all eight IF strips terminating in 100 MHz, 14--bit analog--to--digital converters with synchronized sampling. The advantages of such a configuration are: a) The parallel low and high gain channels allow a higher dynamic range without saturating than a single channel. b) Estimating bispectra between the channels gives a sensitive test for saturation in the higher gain channel. c) In the usual case, when both channels are in their linear region, one can use them with a noise injection diode to track the amplifier noise figures. d) With the noise diode off, the two channels can be used in a mode similar to remote reference. As the telescope is operating in a small city we anticipate that more than 90% of the measurements will be contaminated by various communications signals and impulsive noise. Thus all the signal processing will build on various robust statistical procedures that have proven effective in other applications. The best mode of operating the four active interference cancelling channels is still under study
Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2014-01-01
There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.
NASA Astrophysics Data System (ADS)
Li, P.-D.; Li, X.-Y.; Kang, G.-Z.; Müller, R.
2017-09-01
This paper is devoted to investigating the thermal-induced electric and magnetic polarization saturations (PS) at the tip of a penny-shaped crack embedded in an infinite space of magneto-electro-thermo-elastic medium. In view of the symmetry with respect to the cracked plane, this crack problem is formulated by a mixed boundary value problem. By virtue of the solution to the Abel type integral equation, the governing equations corresponding to the present problem are analytically solved and the generalized crack surface displacement and field intensity factors are obtained in closed-forms. Applying the hypothesis of the electric and magnetic PS model to the analytical results, the sizes of the electric and magnetic yielding zones are determined. Numerical calculations are carried out to reveal the influences of the thermal load and the electric and magnetic yielding strengths on the results, and to show the distributions of the electric and magnetic potentials on the crack surfaces. It is found that the sizes of electric and magnetic yielding zones are mainly dependent on the electric and magnetic yielding strengths, respectively. Since the multi-ferroic media are widely used in various complex thermal environments, the present work could serve as a reference for the designs of various magneto-electric composite structures.
Podestà, M.; Gorelenkova, M.; Gorelenkov, N. N.; ...
2017-07-20
Alfvénic instabilities (AEs) are well known as a potential cause of enhanced fast ion transport in fusion devices. Given a specific plasma scenario, quantitative predictions of (i) expected unstable AE spectrum and (ii) resulting fast ion transport are required to prevent or mitigate the AE-induced degradation in fusion performance. Reduced models are becoming an attractive tool to analyze existing scenarios as well as for scenario prediction in time-dependent simulations. Here, in this work, a neutral beam heated NSTX discharge is used as reference to illustrate the potential of a reduced fast ion transport model, known as kick model, that hasmore » been recently implemented for interpretive and predictive analysis within the framework of the time-dependent tokamak transport code TRANSP. Predictive capabilities for AE stability and saturation amplitude are first assessed, based on given thermal plasma profiles only. Predictions are then compared to experimental results, and the interpretive capabilities of the model further discussed. Overall, the reduced model captures the main properties of the instabilities and associated effects on the fast ion population. Finally, additional information from the actual experiment enables further tuning of the model's parameters to achieve a close match with measurements.« less
Experimental and numerical study on thermal conductivity of partially saturated unconsolidated sands
NASA Astrophysics Data System (ADS)
Lee, Youngmin; Keehm, Youngseuk; Kim, Seong-Kyun; Shin, Sang Ho
2016-04-01
A class of problems in heat flow applications requires an understanding of how water saturation affects thermal conductivity in the shallow subsurface. We conducted a series of experiments using a sand box to evaluate thermal conductivity (TC) of partially saturated unconsolidated sands under varying water saturation (Sw). We first saturated sands fully with water and varied water saturation by drainage through the bottom of the sand box. Five water-content sensors were integrated vertically into the sand box to monitor water saturation changes and a needle probe was embedded to measure thermal conductivity of partially saturated sands. The experimental result showed that thermal conductivity decreases from 2.5 W/mK for fully saturated sands to 0.7 W/mK when water saturation is 5%. We found that the decreasing trend is quite non-linear: highly sensitive at very high and low water saturations. However, the boundary effects on the top and the bottom of the sand box seemed to be responsible for this high nonlinearity. We also found that the determination of water saturation is quite important: the saturation by averaging values from all five sensors and that from the sensor at the center position, showed quite different trends in the TC-Sw domain. In parallel, we conducted a pore-scale numerical modeling, which consists of the steady-state two-phase Lattice-Boltzmann simulator and FEM thermal conduction simulator on digital pore geometry of sand aggregation. The simulation results showed a monotonous decreasing trend, and are reasonably well matched with experimental data when using average water saturations. We concluded that thermal conductivity would decrease smoothly as water saturation decreases if we can exclude boundary effects. However, in dynamic conditions, i.e. imbibition or drainage, the thermal conductivity might show hysteresis, which can be investigated with pore-scale numerical modeling with unsteady-state two-phase flow simulators in our future work.
Sedimentological Control on Hydrate Saturation Distribution in Arctic Gas-Hydrate-Bearing Deposits
NASA Astrophysics Data System (ADS)
Behseresht, J.; Peng, Y.; Bryant, S. L.
2010-12-01
Grain size variations along with the relative rates of fluid phases migrating into the zone of hydrate stability, plays an important role in gas-hydrate distribution and its morphologic characteristics. In the Arctic, strata several meters thick containing large saturations of gas hydrate are often separated by layers containing small but nonzero hydrate saturations. Examples are Mt. Elbert, Alaska and Mallik, NW Territories. We argue that this sandwich type hydrate saturation distribution is consistent with having a gas phase saturation within the sediment when the base of gas hydrate stability zone (BGHSZ) was located above the sediment package. The volume change during hydrate formation process derives movement of fluid phases into the GHSZ. We show that this fluid movement -which is mainly governed by characteristic relative permeability curves of the host sediment-, plays a crucial role in the amount of hydrate saturation in the zone of major hydrate saturation. We develop a mechanistic model that enables estimating the final hydrate saturation from an initial gas/water saturation in sediment with known relative permeability curves. The initial gas/water saturation is predicted using variation of capillary entry pressure with depth, which in turn depends on the variation in grain-size distribution. This model provides a mechanistic approach for explaining large hydrate saturations (60%-75%) observed in zones of major hydrate saturation considering the governing characteristic relative permeability curves of the host sediments. We applied the model on data from Mount Elbert well on the Alaskan North Slope. It is shown that, assuming a cocurrent flow of gas and water into the GHSZ, such large hydrate saturations (up to 75%) cannot result from large initial gas saturations (close to 1-Sw,irr) due to limitations on water flux imposed by typical relative permeability curves. They could however result from modest initial gas saturations (ca. 40%) at which we have reasonable phase mobility ratios required for appropriate relative rates of gas and water transporting into GHSZ to form large hydrate saturations. Nevertheless, from the profile of capillary entry pressure vs. depth, we expect large initial gas saturations and thus the final high hydrate saturation suggests another form of water flow: water moves down through accumulated hydrate from the unfrozen water above. For this to happen the water phase must remain connected within the hydrate-bearing sediment. This seems plausible in hydrate bearing sediments because hydrate formation will be stopped before water saturation gets to very low values (lower than Sw,irr) due to salinity build up. The location of small hydrate saturations (10-15%) is consistent with the location of the residual gas phase established during water imbibition into these locations while they serve as a gas source to the layers above.
Electrical conductivity modeling in fractal non-saturated porous media
NASA Astrophysics Data System (ADS)
Wei, W.; Cai, J.; Hu, X.; Han, Q.
2016-12-01
The variety of electrical conductivity in non-saturated conditions is important to study electric conduction in natural sedimentary rocks. The electrical conductivity in completely saturated porous media is a porosity-function representing the complex connected behavior of single conducting phases (pore fluid). For partially saturated conditions, the electrical conductivity becomes even more complicated since the connectedness of pore. Archie's second law is an empirical electrical conductivity-porosity and -saturation model that has been used to predict the formation factor of non-saturated porous rock. However, the physical interpretation of its parameters, e.g., the cementation exponent m and the saturation exponent n, remains questionable. On basis of our previous work, we combine the pore-solid fractal (PSF) model to build an electrical conductivity model in non-saturated porous media. Our theoretical porosity- and saturation-dependent models contain endmember properties, such as fluid electrical conductivities, pore fractal dimension and tortuosity fractal dimension (representing the complex degree of electrical flowing path). We find the presented model with non-saturation-dependent electrical conductivity datasets indicate excellent match between theory and experiments. This means the value of pore fractal dimension and tortuosity fractal dimension change from medium to medium and depends not only on geometrical properties of pore structure but also characteristics of electrical current flowing in the non-saturated porous media.
Flock, Michael R; Kris-Etherton, Penny M
2013-03-01
The purpose of this review is to discuss the metabolism of long-chain saturated fatty acids and the ensuing effects on an array of metabolic events. Individual long-chain saturated fatty acids exhibit unique biological properties. Dietary saturated fat absorption varies depending on chain-length and the associated food matrix. The in-vivo metabolism of saturated fatty acids varies depending on the individual fatty acid and the nutritional state of the individual. A variety of fatty acid metabolites are formed, each with their own unique structure and properties that warrant further research. Replacing saturated fatty acids with unsaturated fatty acids improves the blood lipid profile and reduces cardiovascular disease risk, although the benefits depend on the specific saturated fatty acid(s) being replaced. Acknowledging the complexity of saturated fatty acid metabolism and associated metabolic events is important when assessing their effects on cardiovascular disease risk. Investigating the biological effects of saturated fatty acids will advance our understanding of how they affect cardiovascular disease risk.
Brugnara, Carlo; Betensky, Rebecca A.; Waikar, Sushrut S.
2015-01-01
Background and objectives Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin’s (Hgb’s) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Design, setting, participants, & measurements Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Results Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (P<0.001). Mean hemoglobin saturation P50 levels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (P<0.001). No significant change was seen in the reference group. 2,3-DPG levels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). Conclusions CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. PMID:25538269
NASA Astrophysics Data System (ADS)
Buytaert, Wouter; Deckers, Jozef; Wyseure, Guido
2006-02-01
The páramo is a neotropical alpine ecosystem that covers more than 75,000 km 2 of the northern Andes of Colombia, Ecuador, Venezuela, and Peru. It provides important environmental services: more than 10 million people in the Andean highlands benefit from the water supply and regulation function, which is attributed to the volcanic soils that underlie the ecosystem. The soils are also major carbon sinks of global significance. Severe land use changes and soil degradation threaten both the hydrology and carbon sink function. Nevertheless, soil genesis and properties in the páramo is rather poorly understood, nor are their ecological functions well documented. The impact of the geomorphology of the páramo on soil genesis was studied in the rio Paute basin, south Ecuador. Two toposequences were described and analysed. In each toposequence, four pedons were selected representing summit, backslope, undrained plain situation, and valley bottom positions in the landscape. The soils are classified as Hydric Andosols in the World Reference Base for Soil Resources and Epiaquands or Hydrudands in Soil Taxonomy. They are very acidic and have a high organic matter content, high P deficiency, and Al toxicity. Their water content ranges from 2.64 g g - 1 at saturation, down to 1.24 g g - 1 at wilting point, resulting in a large water storage capacity. Two major soil forming processes are identified: (1) volcanic ash deposition and (2) accumulation of organic carbon. Volcanic ash deposits may vary in depth as a result of regional geomorphological factors such as parent material, orientation, slope, and altitude. Organic carbon accumulation is an interaction of both waterlogging, which depends on the position in the landscape, and the formation of organometallic complexes with Al and Fe released during volcanic ash breakdown. Despite the high variability in parent material and topography, the soil is characterised by a notable homogeneity in physico-chemical properties. Statistical analysis reveals that only topographic location has a slight but significant influence on soil pH as well as the organic matter content, saturated conductivity and water retention at high pressure. Finally, the exceptional properties of these soils provide useful insights to improve classification of the Andosols reference group of the FAO World reference Base for Soil Resources.
Sharma, Shilpa; Brugnara, Carlo; Betensky, Rebecca A; Waikar, Sushrut S
2015-01-07
Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin's (Hgb's) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (P<0.001). Mean hemoglobin saturation P50 levels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (P<0.001). No significant change was seen in the reference group. 2,3-DPG levels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. Copyright © 2015 by the American Society of Nephrology.
NASA Astrophysics Data System (ADS)
Shibataki, Takuya; Takahashi, Yasuhito; Fujiwara, Koji
2018-04-01
This paper discusses a measurement method for saturation magnetizations of iron core materials using an electromagnet, which can apply an extremely large magnetic field strength to a specimen. It is said that electrical steel sheets are completely saturated at such a large magnetic field strength over about 100 kA/m. The saturation magnetization can be obtained by assuming that the completely saturated specimen shows a linear change of the flux density with the magnetic field strength because the saturation magnetization is constant. In order to accurately evaluate the flux density in the specimen, an air flux between the specimen and a winding of B-coil for detecting the flux density is compensated by utilizing an ideal condition that the incremental permeability of saturated specimen is equal to the permeability of vacuum. An error of magnetic field strength caused by setting a sensor does not affect the measurement accuracy of saturation magnetization. The error is conveniently cancelled because the saturation magnetization is a function of a ratio of the magnetic field strength to its increment. It may be concluded that the saturation magnetization can be easily measured with high accuracy by using the proposed method.
Experimental Investigation of Mechanical Properties of Black Shales after CO2-Water-Rock Interaction
Lyu, Qiao; Ranjith, Pathegama Gamage; Long, Xinping; Ji, Bin
2016-01-01
The effects of CO2-water-rock interactions on the mechanical properties of shale are essential for estimating the possibility of sequestrating CO2 in shale reservoirs. In this study, uniaxial compressive strength (UCS) tests together with an acoustic emission (AE) system and SEM and EDS analysis were performed to investigate the mechanical properties and microstructural changes of black shales with different saturation times (10 days, 20 days and 30 days) in water dissoluted with gaseous/super-critical CO2. According to the experimental results, the values of UCS, Young’s modulus and brittleness index decrease gradually with increasing saturation time in water with gaseous/super-critical CO2. Compared to samples without saturation, 30-day saturation causes reductions of 56.43% in UCS and 54.21% in Young’s modulus for gaseous saturated samples, and 66.05% in UCS and 56.32% in Young’s modulus for super-critical saturated samples, respectively. The brittleness index also decreases drastically from 84.3% for samples without saturation to 50.9% for samples saturated in water with gaseous CO2, to 47.9% for samples saturated in water with super-critical carbon dioxide (SC-CO2). SC-CO2 causes a greater reduction of shale’s mechanical properties. The crack propagation results obtained from the AE system show that longer saturation time produces higher peak cumulative AE energy. SEM images show that many pores occur when shale samples are saturated in water with gaseous/super-critical CO2. The EDS results show that CO2-water-rock interactions increase the percentages of C and Fe and decrease the percentages of Al and K on the surface of saturated samples when compared to samples without saturation. PMID:28773784
Lyu, Qiao; Ranjith, Pathegama Gamage; Long, Xinping; Ji, Bin
2016-08-06
The effects of CO₂-water-rock interactions on the mechanical properties of shale are essential for estimating the possibility of sequestrating CO₂ in shale reservoirs. In this study, uniaxial compressive strength (UCS) tests together with an acoustic emission (AE) system and SEM and EDS analysis were performed to investigate the mechanical properties and microstructural changes of black shales with different saturation times (10 days, 20 days and 30 days) in water dissoluted with gaseous/super-critical CO₂. According to the experimental results, the values of UCS, Young's modulus and brittleness index decrease gradually with increasing saturation time in water with gaseous/super-critical CO₂. Compared to samples without saturation, 30-day saturation causes reductions of 56.43% in UCS and 54.21% in Young's modulus for gaseous saturated samples, and 66.05% in UCS and 56.32% in Young's modulus for super-critical saturated samples, respectively. The brittleness index also decreases drastically from 84.3% for samples without saturation to 50.9% for samples saturated in water with gaseous CO₂, to 47.9% for samples saturated in water with super-critical carbon dioxide (SC-CO₂). SC-CO₂ causes a greater reduction of shale's mechanical properties. The crack propagation results obtained from the AE system show that longer saturation time produces higher peak cumulative AE energy. SEM images show that many pores occur when shale samples are saturated in water with gaseous/super-critical CO₂. The EDS results show that CO₂-water-rock interactions increase the percentages of C and Fe and decrease the percentages of Al and K on the surface of saturated samples when compared to samples without saturation.
Gailly, C; Sandra, P; Verzele, M; Cocito, C
1982-06-15
The cell wall of leprosy-derived corynebacteria (a group of 'diphtheroids' isolated from human leprosy lesions and patients' blood) was previously shown to contain, in addition to peptidoglycan and arabinogalactan, mycolic acids. These alpha-branched beta-hydroxy fatty acids were attributed to the corynomycolic group, according to their RF in monodimensional thin-layer chromatography. In the present work, mycolic acids from leprosy-derived and reference corynebacteria have been fractionated by monodimensional and bidimensional thin-layer chromatography and by gas chromatography. Pyrolyzed mycolic acids have been analyzed on conventional packed columns, whereas intact methyl esters of mycolic acids with free and silylated beta-hydroxyl group have been analyzed on capillary columns, and their structure has been established by mass spectrometry. In all leprosy-derived corynebacteria, some 20 components containing 24-36 carbon atoms and 0-4 double bonds were obtained. The three major groups had 32, 34 and 36 carbons, and the frequency of unsaturated versus saturated chains increased proportionally to the molecular weight. For comparison, the main components of a reference corynebacterium. Corynebacterium diphtheriae PW8, had 30 and 32 carbons, and their hydrocarbon chains were essentially saturated. This work confirms the relative chemical homogeneity of different leprosy-derived corynebacteria and describes some peculiar traits in the chemical structure of this group of organisms. In addition, it shows the complexity of the mycolic acid fraction of corynebacterial cell wall and suggests that the mycolic acid pattern is a sort of fingerprint of each bacterial strain grown under standard conditions. Finally, the fractionation of intact corynomycolic acid methyl esters with free or silylated beta-hydroxyl group by capillary gas chromatography proved to be the best analytical procedure at present available for resolving this complex mixture of corynomycolate isomers. Structural determination of silylated samples by mass spectrometry is preferred because they have more diagnostic fragments.
Wimberley, Catriona J; Fischer, Kristina; Reilhac, Anthonin; Pichler, Bernd J; Gregoire, Marie Claude
2014-10-01
The partial saturation approach (PSA) is a simple, single injection experimental protocol that will estimate both B(avail) and appK(D) without the use of blood sampling. This makes it ideal for use in longitudinal studies of neurodegenerative diseases in the rodent. The aim of this study was to increase the range and applicability of the PSA by developing a data driven strategy for determining reliable regional estimates of receptor density (B(avail)) and in vivo affinity (1/appK(D)), and validate the strategy using a simulation model. The data driven method uses a time window guided by the dynamic equilibrium state of the system as opposed to using a static time window. To test the method, simulations of partial saturation experiments were generated and validated against experimental data. The experimental conditions simulated included a range of receptor occupancy levels and three different B(avail) and appK(D) values to mimic diseases states. Also the effect of using a reference region and typical PET noise on the stability and accuracy of the estimates was investigated. The investigations showed that the parameter estimates in a simulated healthy mouse, using the data driven method were within 10±30% of the simulated input for the range of occupancy levels simulated. Throughout all experimental conditions simulated, the accuracy and robustness of the estimates using the data driven method were much improved upon the typical method of using a static time window, especially at low receptor occupancy levels. Introducing a reference region caused a bias of approximately 10% over the range of occupancy levels. Based on extensive simulated experimental conditions, it was shown the data driven method provides accurate and precise estimates of B(avail) and appK(D) for a broader range of conditions compared to the original method. Copyright © 2014 Elsevier Inc. All rights reserved.
Robinson, P; Hodgson, R; Grainger, A J
2015-01-01
Objective: To assess whether a single isotropic three-dimensional (3D) fast spin echo (FSE) proton density fat-saturated (PD FS) sequence reconstructed in three planes could replace the three PD (FS) sequences in our standard protocol at 1.5 T (Siemens Avanto, Erlangen, Germany). Methods: A 3D FSE PD water excitation sequence was included in the protocol for 95 consecutive patients referred for routine knee MRI. This was used to produce offline reconstructions in axial, sagittal and coronal planes. Two radiologists independently assessed each case twice, once using the standard MRI protocol and once replacing the standard PD (FS) sequences with reconstructions from the 3D data set. Following scoring, the observer reviewed the 3D data set and performed multiplanar reformats to see if this altered confidence. The menisci, ligaments and cartilage were assessed, and statistical analysis was performed using the standard sequence as the reference standard. Results: The reporting accuracy was as follows: medial meniscus (MM) = 90.9%, lateral meniscus (LM) = 93.7%, anterior cruciate ligament (ACL) = 98.9% and cartilage surfaces = 85.8%. Agreement among the readers was for the standard protocol: MM kappa = 0.91, LM = 0.89, ACL = 0.98 and cartilage = 0.84; and for the 3D protocol: MM = 0.86, LM = 0.77, ACL = 0.94 and cartilage = 0.64. Conclusion: A 3D PD FSE sequence reconstructed in three planes gives reduced accuracy and decreased concordance among readers compared with conventional sequences when evaluating the menisci and cartilage with a 1.5-T MRI scanner. Advances in knowledge: Using the existing 1.5-T MR systems, a 3D FSE sequence should not replace two-dimensional sequences. PMID:26067920
Influence of Spanish TV commercials on child obesity.
Ramos, C; Navas, J
2015-06-01
To examine the strategies used in food advertising campaigns on Spanish television and their breach of the Self-Regulation Code on Food Advertising aimed at Preventing Obesity and Promoting Healthy Habits in Children, as such breach advocates the consumption of products that fail to meet the nutritional requirements. Observational descriptive study. Viewing and content analysis of 52 food commercials on the children's television channels 'Disney Channel' and 'Boing' on Saturday and Sunday (9:00-12:00) and general channels 'Telecinco' and 'Antena 3' on Monday to Friday (8:00-9:00 and 17:00-20:00), from March to May 2013; subsequent analysis of the nutrition labelling of the advertised products. There are different ways of bypassing the advertising agreement. Strategies are used which hide or distort the facts about the product in favour of the advertiser. 18 advertisements refer to website or Facebook pages, thus facilitating feedback, and 11 advertisements refer to the Plan for Promoting Healthy Lifestyles in the Spanish Population. With regard to nutritional quality, the composition of the products analysed is high in sugars and saturated fats with average levels of fat and salt. A comparison of the broadcast time of the commercials shows that the figures for fat and saturated fat are similar in food advertised in the morning and in the afternoon, but products that are high in sugar and salt are advertised more in the morning. If the overall figures are compared, they are higher in foods advertised in the morning. The Self-Regulation Code is insufficient. There is an obvious risk of trivialising the messages of the health promotion plan. The regulation of advertising is complex and if the nutritional composition of the foods advertised is likely to lead to child obesity, it is essential to reflect on the consequences deriving from the advertising of these products. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dahms, Rainer N.
2014-12-31
The fidelity of Gradient Theory simulations depends on the accuracy of saturation properties and influence parameters, and require equations of state (EoS) which exhibit a fundamentally consistent behavior in the two-phase regime. Widely applied multi-parameter EoS, however, are generally invalid inside this region. Hence, they may not be fully suitable for application in concert with Gradient Theory despite their ability to accurately predict saturation properties. The commonly assumed temperature-dependence of pure component influence parameters usually restricts their validity to subcritical temperature regimes. This may distort predictions for general multi-component interfaces where temperatures often exceed the critical temperature of vapor phasemore » components. Then, the calculation of influence parameters is not well defined. In this paper, one of the first studies is presented in which Gradient Theory is combined with a next-generation Helmholtz energy EoS which facilitates fundamentally consistent calculations over the entire two-phase regime. Illustrated on pentafluoroethane as an example, reference simulations using this method are performed. They demonstrate the significance of such high-accuracy and fundamentally consistent calculations for the computation of interfacial properties. These reference simulations are compared to corresponding results from cubic PR EoS, widely-applied in combination with Gradient Theory, and mBWR EoS. The analysis reveals that neither of those two methods succeeds to consistently capture the qualitative distribution of obtained key thermodynamic properties in Gradient Theory. Furthermore, a generalized expression of the pure component influence parameter is presented. This development is informed by its fundamental definition based on the direct correlation function of the homogeneous fluid and by presented high-fidelity simulations of interfacial density profiles. As a result, the new model preserves the accuracy of previous temperature-dependent expressions, remains well-defined at supercritical temperatures, and is fully suitable for calculations of general multi-component two-phase interfaces.« less
NASA Astrophysics Data System (ADS)
Feldstein, Tamar; Kashman, Yoel; Abelson, Avigdor; Fishelson, Lev; Mokady, Ofer; Bresler, Vladimir; Erel, Yigal
2003-10-01
Concentrations of trace elements and organic pollutants were determined in marine sediments and molluscs from the Mediterranean and Red Sea coasts of Israel. Two bivalve species (Donax trunculus, Pteria aegyptia), two gastropod species (Patella caerulea, Cellana rota) and sediments were sampled at polluted and relatively clean, reference, sites. Along the Mediterranean coast of Israel, sediments and molluscs from Haifa Bay stations were enriched with both organic and trace element contaminants. In the Red Sea, differences between the polluted and reference sites were less pronounced. Bio-concentration factors indicate a significant concentration of Zn, As, Cd, Sn and Pb in animal tissue relative to the concentrations of these elements in the sediments. In contrast, Ce, La and U were not concentrated in molluscs. The trace element results indicate a saturation of the detoxification mechanisms in molluscs from polluted sites. The concentrations of organic pollutants at the same sites are at the lower range of values recorded in other studies. However, synergistic effects between these compounds and between them and metals can lead to acute toxicity.
NASA Astrophysics Data System (ADS)
Astik, Mitesh B.; Bhatt, Praghnesh; Bhalja, Bhavesh R.
2017-03-01
A sensorless control scheme based on an unknown input observer is presented in this paper in which back EMF of the Brushless DC Motor (BLDC) is continuously estimated from available line voltages and currents. During negative rotation of motor, actual and estimated speed fail to track the reference speed and if the corrective action is not taken by the observer, the motor goes into saturation. To overcome this problem, the speed estimation algorithm has been implemented in this paper to control the dynamic behavior of the motor during negative rotation. The Ackermans method was used to calculate the gains of an unknown input observer which is based on the appropriate choice of the eigenvalues in advance. The criteria to choose eigenvalue is to obtain a balance between faster convergence rate and the least noise level. Simulations have been carried out for different disturbances such as step changes in motor reference speed and load torque. The comparative simulation results clearly depict that the disturbance effects in actual and estimated responses minimizes as observer gain setting increases.
Meeting the nutrient reference values on a vegetarian diet.
Reid, Michelle A; Marsh, Kate A; Zeuschner, Carol L; Saunders, Angela V; Baines, Surinder K
2013-08-19
Surveys over the past 10 years have shown that Australians are increasingly consuming more plant-based vegetarian meals. Many studies demonstrate the health benefits of vegetarian diets. As with any type of eating plan, vegetarian diets must be well planned to ensure nutritional needs are being met. This clinical focus project shows that well planned vegetarian diets can meet almost all the nutritional needs of children and adults of all ages. Sample single-day lacto-ovo-vegetarian meal plans were developed to comply with the nutrient reference values - including the increased requirements for iron and zinc at 180% and 150%, respectively, for vegetarians - for both sexes and all age groups set by Australia's National Health and Medical Research Council and the New Zealand Ministry of Health. With the exception of vitamin D, long-chain omega-3 fatty acids and extended iron requirements in pregnancy for vegetarians, the meal plans meet key requirements with respect to energy; protein; carbohydrate; total fat; saturated, poly- and monounsaturated fats; α-linolenic acid; fibre; iron; zinc; calcium; folate; and vitamins A, C, E and B₁₂.
Modeling and closed-loop control of hypnosis by means of bispectral index (BIS) with isoflurane.
Gentilini, A; Rossoni-Gerosa, M; Frei, C W; Wymann, R; Morari, M; Zbinden, A M; Schnider, T W
2001-08-01
A model-based closed-loop control system is presented to regulate hypnosis with the volatile anesthetic isoflurane. Hypnosis is assessed by means of the bispectral index (BIS), a processed parameter derived from the electroencephalogram. Isoflurane is administered through a closed-circuit respiratory system. The model for control was identified on a population of 20 healthy volunteers. It consists of three parts: a model for the respiratory system, a pharmacokinetic model and a pharmacodynamic model to predict BIS at the effect compartment. A cascaded internal model controller is employed. The master controller compares the actual BIS and the reference value set by the anesthesiologist and provides expired isoflurane concentration references to the slave controller. The slave controller maneuvers the fresh gas anesthetic concentration entering the respiratory system. The controller is designed to adapt to different respiratory conditions. Anti-windup measures protect against performance degradation in the event of saturation of the input signal. Fault detection schemes in the controller cope with BIS and expired concentration measurement artifacts. The results of clinical studies on humans are presented.
Book review: Estimating groundwater recharge
Stonestrom, David A.
2011-01-01
Groundwater recharge is the entry of fresh water into the saturated portion of the subsurface part of the hydrologic cycle, the modifier “saturated” indicating that the pressure of the pore water is greater than atmospheric. Briefly stated, recharge is downward flux across the water table. The term “groundwater recharge” can refer either to the multiple interacting processes generating and controlling the flux or to the fluxR itself. When referring to flux, R can represent either (1) a value integrated over large areas and long periods of time or (2) a point value, or instantaneous flux density, that varies erratically as well as continuously in time and space. Knowing how R is distributed through space and time is required for understanding the dynamics of groundwater flow and transport in any watershed, aquifer, or selected domain of interest and for understanding heads, flow paths, and discharges to streams, wetlands, and other surface water bodies. Clearly among the most important of hydrologic fluxes, R is also one of the most difficult to measure. Advancements in hydrologic science have proceeded surprisingly in lockstep with advances in determining R.
Nurse opinions and pulse oximeter saturation target limits for preterm infants.
Nghiem, Tuyet-Hang; Hagadorn, James I; Terrin, Norma; Syke, Sally; MacKinnon, Brenda; Cole, Cynthia H
2008-05-01
The objectives of this study were to compare pulse oximeter saturation limits targeted by nurses for extremely preterm infants during routine care with nurse opinions regarding appropriate pulse oximeter saturation limits and with policy-specified pulse oximeter saturation limits and to identify factors that influence pulse oximeter saturation limits targeted by nurses. We surveyed nurses in US NICUs with neonatal-perinatal fellowships in 2004. Data collected included pulse oximeter saturation limits targeted by nurses and by NICU policy when present, nurses' opinions about appropriate pulse oximeter saturation limits, and NICU and nurse characteristics. Factors associated with pulse oximeter saturation limits targeted by nurses were identified with hierarchical linear modeling. Among those eligible, 2805 (45%) nurses in 59 (60%) NICUs responded. Forty (68%) of 59 NICUs had a policy that specified a pulse oximeter saturation target range for extremely preterm infants. Among 1957 nurses at NICUs with policies, 540 (28%) accurately identified the upper and lower limits of their NICU's policy and also targeted these values in practice. NICU-specific SDs for individual nurse target limits were less at NICUs with versus without a policy for both upper and lower limits. Hierarchical linear modeling identified presence of pulse oximeter saturation policy, NICU-specific nurse group opinion, and individual nurse opinion as factors significantly associated with individual pulse oximeter saturation target limits. For each percentage point increase in individual opinion upper limit, the individual target upper limit increased by 0.41 percentage point at NICUs with a policy compared with 0.6 percentage point at NICUs with no policy. Presence of policy-specified pulse oximeter saturation limits, nurse group opinion, and individual nurse opinion were independently associated with individual nurse pulse oximeter saturation target limits during routine care of extremely preterm infants. The presence of a policy reduced the influence of individual nurse opinion on targeted pulse oximeter saturation limits and reduced variation among nurse target limits within NICUs.
Davis, Bradley; Welch, Katherine; Walsh-Hart, Sharon; Hanseman, Dennis; Petro, Michael; Gerlach, Travis; Dorlac, Warren; Collins, Jocelyn; Pritts, Timothy
2014-08-01
Critical Care Air Transport Teams (CCATTs) are a critical component of the United States Air Force evacuation paradigm. This study was conducted to assess the incidence of task saturation in simulated CCATT missions and to determine if there are predictable performance domains. Sixteen CCATTs were studied over a 6-month period. Performance was scored using a tool assessing eight domains of performance. Teams were also assessed during critical events to determine the presence or absence of task saturation and its impact on patient care. Sixteen simulated missions were reviewed and 45 crisis events identified. Task saturation was present in 22/45 (49%) of crisis events. Scoring demonstrated that task saturation was associated with poor performance in teamwork (odds ratio [OR] = 1.96), communication (OR = 2.08), and mutual performance monitoring (OR = 1.9), but not maintenance of guidelines, task management, procedural skill, and equipment management. We analyzed the effect of task saturation on adverse patient outcomes during crisis events. Adverse outcomes occurred more often when teams were task saturated as compared to non-task-saturated teams (91% vs. 23%; RR 4.1, p < 0.0001). Task saturation is observed in simulated CCATT missions. Nontechnical skills correlate with task saturation. Task saturation is associated with worsening physiologic derangements in simulated patients. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Hong, Ye-Ji; Ahn, Hyo-Ju; Shin, Jongdae; Lee, Joon H; Kim, Jin-Hoi; Park, Hwan-Woo; Lee, Sung Ki
2018-02-01
Dysregulated serum fatty acids are associated with a lipotoxic placental environment, which contributes to increased pregnancy complications via altered trophoblast invasion. However, the role of saturated and unsaturated fatty acids in trophoblastic autophagy has yet to be explored. Here, we demonstrated that prolonged exposure of saturated fatty acids interferes with the invasiveness of human extravillous trophoblasts. Saturated fatty acids (but not unsaturated fatty acids) inhibited the fusion of autophagosomes and lysosomes, resulting in the formation of intracellular protein aggregates. Furthermore, when the trophoblast cells were exposed to saturated fatty acids, unsaturated fatty acids counteracted the effects of saturated fatty acids by increasing degradation of autophagic vacuoles. Saturated fatty acids reduced the levels of the matrix metalloproteinases (MMP)-2 and MMP-9, while unsaturated fatty acids maintained their levels. In conclusion, saturated fatty acids induced decreased trophoblast invasion, of which autophagy dysfunction plays a major role. Copyright © 2017 Elsevier B.V. All rights reserved.
Chowdhury, Muhammad E H; Mullinger, Karen J; Glover, Paul; Bowtell, Richard
2014-01-01
Large artefacts compromise EEG data quality during simultaneous fMRI. These artefact voltages pose heavy demands on the bandwidth and dynamic range of EEG amplifiers and mean that even small fractional variations in the artefact voltages give rise to significant residual artefacts after average artefact subtraction. Any intrinsic reduction in the magnitude of the artefacts would be highly advantageous, allowing data with a higher bandwidth to be acquired without amplifier saturation, as well as reducing the residual artefacts that can easily swamp signals from brain activity measured using current methods. Since these problems currently limit the utility of simultaneous EEG-fMRI, new approaches for reducing the magnitude and variability of the artefacts are required. One such approach is the use of an EEG cap that incorporates electrodes embedded in a reference layer that has similar conductivity to tissue and is electrically isolated from the scalp. With this arrangement, the artefact voltages produced on the reference layer leads by time-varying field gradients, cardiac pulsation and subject movement are similar to those induced in the scalp leads, but neuronal signals are not detected in the reference layer. Taking the difference of the voltages in the reference and scalp channels will therefore reduce the artefacts, without affecting sensitivity to neuronal signals. Here, we test this approach by using a simple experimental realisation of the reference layer to investigate the artefacts induced on the leads attached to the reference layer and scalp and to evaluate the degree of artefact attenuation that can be achieved via reference layer artefact subtraction (RLAS). Through a series of experiments on phantoms and human subjects, we show that RLAS significantly reduces the gradient (GA), pulse (PA) and motion (MA) artefacts, while allowing accurate recording of neuronal signals. The results indicate that RLAS generally outperforms AAS when motion is present in the removal of the GA and PA, while the combination of AAS and RLAS always produces higher artefact attenuation than AAS. Additionally, we demonstrate that RLAS greatly attenuates the unpredictable and highly variable MAs that are very hard to remove using post-processing methods. © 2013. Published by Elsevier Inc. All rights reserved.
Some Boussinesq Equations with Saturation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christou, M. A.
2010-11-25
We investigate numerically some Boussinesq type equations with square or cubic and saturated nonlinearity. We examine the propagation, interaction and overtake interaction of soliton solutions. Moreover, we examine the effect of the saturation term on the solution and compare it with the classical case of the square or cubic nonlinearity without saturation. We calculate numerically the phase shift experienced by the solitons upon collision and conclude the impact of saturation.
Stella, João Paulo Fragomeni; Barletta, Fernando Branco; Giovanella, Larissa Bergesch; Grazziotin-Soares, Renata; Tovo, Maximiano Ferreira; Felippe, Wilson Tadeu; Estrela, Carlos
2015-09-01
The objective of this study was to use pulse oximetry to measure oxygen saturation in permanent maxillary central incisors with normal pulp in 2 different age groups: children/adolescents and adults. Blood oxygen saturation levels were measured using a pulse oximeter in 110 maxillary central incisors of 57 individuals, in 1 of 2 possible age bands, as follows: 28 children/adolescents (7-13 years old) and 29 adults (22-36 years old). The following factors were also analyzed: (1) heart rate (beats/min); (2) oxygen saturation rate measured at the patient's index finger, also using a pulse oximeter; (3) tooth crown dimensions; and (4) the time taken by the oximeter to provide a reading. The mean oxygen saturation level in normal central incisors was higher among children/adolescents (84.35%) than adults (77.88%, P = .003). Oxygen saturation rates measured at the patients' fingers were not correlated with saturation obtained at the teeth (r = 0.10). There was no correlation between oxygen saturation readings and tooth dimensions (buccal surface area), heart rate, or oximeter reading time (P > .05). Oxygen saturation values measured in maxillary central incisors using a pulse oximeter revealed differences between children/adolescents and adults, showing that children/adolescents have higher oxygen saturation levels. There was no correlation between oxygen saturation levels in patients' fingers and values from their teeth or between oxygen saturation readings from central incisors and tooth dimensions (buccal surface), heart rate, or oximeter reading time. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Youwen; Dai, Zhiping; Ling, Xiaohui; Chen, Liezun; Lu, Shizhuan; You, Kaiming
2016-11-01
In high-power laser system such as Petawatt lasers, the laser beam can be intense enough to result in saturation of nonlinear refraction index of medium. Based on the standard linearization method of small-scale self-focusing and the split-step Fourier numerical calculation method, we present analytical and simulative investigations on the hot-image formation in cascaded saturable nonlinear medium slabs, to disclose the effect of nonlinearity saturation on the distribution and intensity of hot images. The analytical and simulative results are found in good agreement. It is shown that, saturable nonlinearity does not change the distribution of hot images, while may greatly affect the intensity of hot images, i.e., for a given saturation light intensity, with the intensity of the incident laser beam, the intensity of hot images firstly increases monotonously and eventually reaches a saturation; for the incident laser beam of a given intensity, with the saturation light intensity lowering, the intensity of hot images decreases rapidly, even resulting in a few hot images too weak to be visible.
NASA Technical Reports Server (NTRS)
Righter, K.
2000-01-01
Highly siderophile elements provide important constraints on planetary differentiation due to their siderophile behavior. Their interpretation in terms of planetary differentiation models has so far overlooked the importance of sulfide saturation and under-saturation.
Dennis, A; Hardy, L
2016-11-01
Early warning systems (EWS), used to identify deteriorating hospitalised patients, are based on measurement of vital signs. When the patients are pregnant, most EWS still use non-pregnant reference ranges of vital signs to determine trigger thresholds. There are no published reference ranges for all vital signs in pregnancy. We aimed to define vital signs reference ranges for term pregnancy in the preoperative period, and to determine the appropriateness of EWS trigger criteria in pregnancy. We conducted a one-year retrospective study in a tertiary referral obstetric hospital. The study sample was healthy term women undergoing planned caesarean section (CS). Systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), oxygen saturation (SpO 2 ) and temperature were all measured automatically and data was extracted from the medical record. Two hundred and fifty-eight women met inclusion criteria. Results were (mean ± SD [standard deviation]) SBP 118 ± 11.2 mmHg, DBP 75 ± 10.3 mmHg, HR 84 ± 10.2 /minute, respiratory rate 18 ± 1.5 /minute, SpO 2 99% ± 1.0% and temperature 36.4°C ± 0.43°C. The reference ranges (mean ± 2SD) determined were SBP 96-140 mmHg, DBP 54-96 mmHg, HR 64-104/minute, RR 15-21 /minute, SpO 2 97%-100% and temperature 35.5°C-37.3°C. This study defined a reference range for vital signs in healthy term pregnant women undergoing CS. Study findings suggest that currently used criteria for EWS triggers, based on non-pregnant values, may be too extreme for timely detection of deteriorating pregnant patients. Further research examining the modified HR triggers of ≤50 and ≥110 /minute in pregnant women and their relationship to clinical outcomes is required.
Velocity of water flow along saturated loess slopes under erosion effects
NASA Astrophysics Data System (ADS)
Huang, Yuhan; Chen, Xiaoyan; Li, Fahu; Zhang, Jing; Lei, Tingwu; Li, Juan; Chen, Ping; Wang, Xuefeng
2018-06-01
Rainfall or snow-melted water recharge easily saturates loose top soils with a less permeable underlayer, such as cultivated soil slope and partially thawed top soil layer, and thus, may influence the velocity of water flow. This study suggested a methodology and device system to supply water from the bottom soil layer at the different locations of slopes. Water seeps into and saturates the soil, when the water level is controlled at the same height of the soil surface. The structures and functions of the device, the components, and the operational principles are described in detail. A series of laboratory experiments were conducted under slope gradients of 5°, 10°, 15°, and 20° and flow rates of 2, 4, and 8 L min-1 to measure the water flow velocities over eroding and non-eroded loess soil slopes, under saturated conditions by using electrolyte tracing. Results showed that flow velocities on saturated slopes were 17% to 88% greater than those on non-saturated slopes. Flow velocity increased rapidly under high flow rates and slope gradients. Saturation conditions were suitable in maintaining smooth rill geomorphology and causing fast water flow. The saturated soil slope had a lubricant effect on the soil surface to reduce the frictional force, resulting in high flow velocity. The flow velocities of eroding rills under different slope gradients and flow rates were approximately 14% to 33% lower than those of non-eroded rills on saturated loess slopes. Compared with that on a saturated loess slope, the eroding rill on a non-saturated loess slope can produce headcuts to reduce the flow velocity. This study helps understand the hydrodynamics of soil erosion and sediment transportation of saturated soil slopes.
Shuttle entry guidance revisited
NASA Technical Reports Server (NTRS)
Mease, Kenneth D.; Kremer, Jean-Paul
1992-01-01
The Shuttle entry guidance concept is reviewed which is aimed at tracking a reference drag trajectory that leads to the specified range and velocity for the initiation of the terminal energy management phase. An approximate method of constructing the domain of attraction is proposed, and its validity is ascertained by simulation. An alternative guidance law yielding global exponential tracking in the absence of control saturation is derived using a feedback linearization method. It is noted that the alternative guidance law does not improve on the stability and performance of the current guidance law, for the operating domain and control capability of the Shuttle. It is suggested that the new guidance law with a larger operating domain and increased lift-to-drag capability would be superior.
Dantas, Mara de Oliveira Rodrigues Luiz; Auler, José Otávio Costa; Andrade, Claudia Regina Furquim de
2010-01-01
Swallowing evaluation of older individuals with coronary disease referred to heart surgery. To identify the characteristics of the swallowing function in older individuals referred to myocardial revascularization surgery (MR), using an evaluating protocol composed by a water test, cervical auscultation and pulse oximetry. The Assessment Protocol for Dysphagia Risk through a Combined Swallowing test and Vital Signs monitoring was used (PADTC)--measurements of HR and SpO2 (heart rate and oxygen saturation), water swallowing test with 1, 3, 5, 10, 15 e 20 ml, measurement of respiratory rate and cervical auscultation. The electronic stethoscope was used to analyze the number of swallows, response time and swallowing sound classification. In the Research Group (RG) older individuals with heart disease who were referred to MR were included. In the Control Group (CG) healthy older individuals were included. 38 older individuals were evaluated in the RG (mean age 68 years). In the CG, 30 older individuals were evaluated (mean age 70 years). There was a significant difference for the swallowing response time in older individuals with heart disease who presented HR below 60: swallowing response was shorter for 3 ml, 10 ml, 15 ml e 20 ml. HR was lower for individuals with heart disease. No significant difference was found between the groups for the other analyzed parameters. Older individuals with heart disease presented differences in the swallowing function when compared to healthy older individuals. Older individuals with heart disease presented alterations in the temporal coordination between breathing and swallowing, thus indicating risk for dysphagia.
Schürer, M; Walter, A; Brünner, H; Langenbucher, A
2015-08-01
Colored transparent filters cause a change in color perception and have an impact on the perceptible amount of different colors and especially on the ability to discriminate between them. Yellow or orange tinted contact lenses worn to enhance contrast vision by reducing or blocking short wavelengths also have an effect on color perception. The impact of the yellow and orange tinted contact lenses Wöhlk SPORT CONTRAST on color discrimination was investigated with the Erlangen colour measurement system in a study with 14 and 16 subjects, respectively. In relation to a yellow reference color located at u' = 0.2487/v' = 0.5433, measurements of color discrimination thresholds were taken in up to 6 different color coordinate axes. Based on these thresholds, color discrimination ellipses were calculated. These results are given in the Derrington, Krauskopf and Lennie (DKL) color system. Both contact lenses caused a shift of the reference color towards higher saturated colors. Color discrimination ability with the yellow and orange colored lenses was significantly enhanced along the blue-yellow axis in comparison to the reference measurements without a tinted filter. Along the red-green axis only the orange lens caused a significant reduction of color discrimination threshold distance to the reference color. Yellow and orange tinted contact lenses enhance the ability of color discrimination. If the transmission spectra and the induced changes are taken into account, these results can also be applied to other filter media, such as blue filter intraocular lenses.
Food consumption in patients referred for bariatric surgery with and without binge eating disorder.
Horvath, Jaqueline Driemeyer Correia; Kops, Natália Luiza; de Castro, Mariana Laitano Dias; Friedman, Rogério
2015-12-01
The prevalence of Binge Eating Disorder (BED) is high in obese patients referred to bariatric surgery. Although the total energy intake is increased, the risk of nutritional deficiencies in these patients is unknown. This study proposes to evaluate and compare the intakes of candidate patients for bariatric surgery with and without BED, using for this purpose the Dietary Reference Intakes. 116 patients referred for bariatric surgery were submitted to nutritional, laboratory and psychological assessments. Among the patients, 46.6% had BED, of these, 25.9% had the severe form. The patients with current depression (31.9%) were more compulsive than those without depression (p < 0.001). The mean age was significantly higher in patients without BED (46.94 ± 12.05 vs 42.32 ± 10.60, p = 0.030). The only difference in anthropometric parameters individuals with and without BED was the mid-upper arm circumference (P = 0.047). The percentage of energy from carbohydrates was higher in patients with BED (53.78%) than without BED (48.88%) (U = 1222, P = 0.018, r = − 0.22). The percentage from total fat (13.63% versus 12.89%, U = 1201.0, P = 0.019, r = − 0.22) and from saturated fat (9.04% versus 8.15%, U = 1074.0, P = 0.023, r = − 0.21), was higher in patients without BED. When adjusted for the body weight of patients, these differences were not significant. Patients with BED eat more carbohydrates and have larger mid-upper arm circumference in the face of similar body weight, suggesting a higher percentage of fat mass.
Lipid order, saturation and surface property relationships: a study of human meibum saturation.
Mudgil, Poonam; Borchman, Douglas; Yappert, Marta C; Duran, Diana; Cox, Gregory W; Smith, Ryan J; Bhola, Rahul; Dennis, Gary R; Whitehall, John S
2013-11-01
Tear film stability decreases with age however the cause(s) of the instability are speculative. Perhaps the more saturated meibum from infants may contribute to tear film stability. The meibum lipid phase transition temperature and lipid hydrocarbon chain order at physiological temperature (33 °C) decrease with increasing age. It is reasonable that stronger lipid-lipid interactions could stabilize the tear film since these interactions must be broken for tear break up to occur. In this study, meibum from a pool of adult donors was saturated catalytically. The influence of saturation on meibum hydrocarbon chain order was determined by infrared spectroscopy. Meibum is in an anhydrous state in the meibomian glands and on the surface of the eyelid. The influence of saturation on the surface properties of meibum was determined using Langmuir trough technology. Saturation of native human meibum did not change the minimum or maximum values of hydrocarbon chain order so at temperatures far above or below the phase transition of human meibum, saturation does not play a role in ordering or disordering the lipid hydrocarbon chains. Saturation did increase the phase transition temperature in human meibum by over 20 °C, a relatively high amount. Surface pressure-area studies showing the late take off and higher maximum surface pressure of saturated meibum compared to native meibum suggest that the saturated meibum film is quite molecularly ordered (stiff molecular arrangement) and elastic (molecules are able to rearrange during compression and expansion) compared with native meibum films which are more fluid agreeing with the infrared spectroscopic results of this study. In saturated meibum, the formation of compacted ordered islands of lipids above the surfactant layer would be expected to decrease the rate of evaporation compared to fluid and more loosely packed native meibum. Higher surface pressure observed with films of saturated meibum compared to native meibum suggests greater film stability especially under the high shear stress of a blink. Copyright © 2013 Elsevier Ltd. All rights reserved.
Assessing species saturation: conceptual and methodological challenges.
Olivares, Ingrid; Karger, Dirk N; Kessler, Michael
2018-05-07
Is there a maximum number of species that can coexist? Intuitively, we assume an upper limit to the number of species in a given assemblage, or that a lineage can produce, but defining and testing this limit has proven problematic. Herein, we first outline seven general challenges of studies on species saturation, most of which are independent of the actual method used to assess saturation. Among these are the challenge of defining saturation conceptually and operationally, the importance of setting an appropriate referential system, and the need to discriminate among patterns, processes and mechanisms. Second, we list and discuss the methodological approaches that have been used to study species saturation. These approaches vary in time and spatial scales, and in the variables and assumptions needed to assess saturation. We argue that assessing species saturation is possible, but that many studies conducted to date have conceptual and methodological flaws that prevent us from currently attaining a good idea of the occurrence of species saturation. © 2018 Cambridge Philosophical Society.
Saturated fatty acids and risk of coronary heart disease: modulation by replacement nutrients.
Siri-Tarino, Patty W; Sun, Qi; Hu, Frank B; Krauss, Ronald M
2010-11-01
Despite the well-established observation that substitution of saturated fats for carbohydrates or unsaturated fats increases low-density lipoprotein (LDL) cholesterol in humans and animal models, the relationship of saturated fat intake to risk for atherosclerotic cardiovascular disease in humans remains controversial. A critical question is what macronutrient should be used to replace saturated fat. Substituting polyunsaturated fat for saturated fat reduces LDL cholesterol and the total cholesterol to high-density lipoprotein cholesterol ratio. However, replacement of saturated fat by carbohydrates, particularly refined carbohydrates and added sugars, increases levels of triglyceride and small LDL particles and reduces high-density lipoprotein cholesterol, effects that are of particular concern in the context of the increased prevalence of obesity and insulin resistance. Epidemiologic studies and randomized clinical trials have provided consistent evidence that replacing saturated fat with polyunsaturated fat, but not carbohydrates, is beneficial for coronary heart disease. Therefore, dietary recommendations should emphasize substitution of polyunsaturated fat and minimally processed grains for saturated fat.
NASA Astrophysics Data System (ADS)
Wang, J.; Polivka, T. N.; Hyer, E. J.; Peterson, D. A.
2014-12-01
Unlike previous space-borne Earth-observing sensors, the Visible Infrared Imaging Radiometer Suite (VIIRS) employs aggregation to reduce downlink bandwidth requirements and preserve spatial resolution across the swath. To examine the potentially deleterious impacts of aggregation when encountering detector saturation, nearly four months of NOAA's Nightfire product were analyzed, which contains a subset of the hottest observed nighttime pixels. An empirical method for identifying saturation was devised. The 3.69 µm band (M12) was the most frequently-saturating band with 0.15% of the Nightfire pixels at or near the ~359 K hard saturation limit, with possible saturation also occurring in M14, M15, and M16. Artifacts consistent with detector saturation were seen with M12 temperatures as low as 330 K in the scene center. This partial saturation and aggregation influence must be considered when using VIIRS radiances for quantitative characterization of hot emission sources such as fires and gas flaring.
On the theory of electric double layer with explicit account of a polarizable co-solvent.
Budkov, Yu A; Kolesnikov, A L; Kiselev, M G
2016-05-14
We present a continuation of our theoretical research into the influence of co-solvent polarizability on a differential capacitance of the electric double layer. We formulate a modified Poisson-Boltzmann theory, using the formalism of density functional approach on the level of local density approximation taking into account the electrostatic interactions of ions and co-solvent molecules as well as their excluded volume. We derive the modified Poisson-Boltzmann equation, considering the three-component symmetric lattice gas model as a reference system and minimizing the grand thermodynamic potential with respect to the electrostatic potential. We apply present modified Poisson-Boltzmann equation to the electric double layer theory, showing that accounting for the excluded volume of co-solvent molecules and ions slightly changes the main result of our previous simplified theory. Namely, in the case of small co-solvent polarizability with its increase under the enough small surface potentials of electrode, the differential capacitance undergoes the significant growth. Oppositely, when the surface potential exceeds some threshold value (which is slightly smaller than the saturation potential), the increase in the co-solvent polarizability results in a differential capacitance decrease. However, when the co-solvent polarizability exceeds some threshold value, its increase generates a considerable enhancement of the differential capacitance in a wide range of surface potentials. We demonstrate that two qualitatively different behaviors of the differential capacitance are related to the depletion and adsorption of co-solvent molecules at the charged electrode. We show that an additive of the strongly polarizable co-solvent to an electrolyte solution can shift significantly the saturation potential in two qualitatively different manners. Namely, a small additive of strongly polarizable co-solvent results in a shift of saturation potential to higher surface potentials. On the contrary, a sufficiently large additive of co-solvent shifts the saturation potential to lower surface potentials. We obtain that an increase in the co-solvent polarizability makes the electrostatic potential profile longer-ranged. However, increase in the co-solvent concentration in the bulk leads to non-monotonic behavior of the electrostatic potential profile. An increase in the co-solvent concentration in the bulk at its sufficiently small values makes the electrostatic potential profile longer-ranged. Oppositely, when the co-solvent concentration in the bulk exceeds some threshold value, its further increase leads to decrease in electrostatic potential at all distances from the electrode.
Textural and geochemical constraints on eruptive style of the 79AD eruption at Vesuvius
NASA Astrophysics Data System (ADS)
Balcone-Boissard, Hélène; Boudon, Georges; Villemant, Benoît.
2010-05-01
The 79AD eruption of Vesuvius, also known as the "Pompeii eruption", is the reference for one of the explosive eruptive styles, the plinian-type eruption. The eruption involved H2O-rich phonolitic magmas and is commonly divided into three phases: an initial phreatomagmatic phase, followed by a plinian event which produced a thick pumice fallout deposit and a final phase that was dominated by numerous column-collapse events. During the plinian phase, a first white pumice fallout was produced from a high steady eruptive column, followed by a grey pumice fallout originated by an oscillatory eruptive column with several partial column collapse events. This study focuses on the pumice fallout deposits, sampled in a proximal thick section, at the Terzigno quarry, 6 km southeast of the present crater. In order to constrain the degassing processes and the eruptive dynamics, major element compositions, residual volatile contents (H2O, Cl) and textural characteristics (vesicularity and microcrystallinity) were studied. A previous study that we performed on the pre-eruptive Cl content has shown that Cl may be used as an indicator of magma saturation with Cl-rich fluids and of pre-eruptive pressures. Cl contents measured in melt inclusions show that only the white pumice and the upper part of the grey pumice magma were H2O saturated prior eruption. Large variations in residual volatile contents exist between the different eruptive units and textural features strongly differ between white and grey pumice clasts but also within the grey pumice clasts. The degassing processes were thus highly heterogeneous: the white pumice eruptive units represent a typical closed-system degassing evolution whereas the first grey pumice one, stored in the same pre-eruptive saturation conditions, follows a particular open-system degassing evolution. Here we propose a new model of the 79AD eruption where pre-eruptive conditions (H2O saturation, magma temperature and viscosity) are the critical parameters which determine the diversity of the syn-eruptive degassing processes and hence the eruptive dynamics. We suggest that the oscillatory regime that dominates the grey pumice eruptive phase is linked to the pre-eruptive water undersaturation of most part of the grey magma and to the time delays necessary for H2O exsolution.
NASA Astrophysics Data System (ADS)
Hoang, Linh; Schneiderman, Elliot; Mukundan, Rajith; Moore, Karen; Owens, Emmet; Steenhuis, Tammo
2017-04-01
Surface runoff is the primary mechanism transporting substances such as sediments, agricultural chemicals, and pathogens to receiving waters. In order to predict runoff and pollutant fluxes, and to evaluate management practices, it is essential to accurately predict the areas generating surface runoff, which depend on the type of runoff: infiltration-excess runoff and saturation-excess runoff. The watershed of Cannonsville reservoir is part of the New York City water supply system that provides high quality drinking water to nine million people in New York City (NYC) and nearby communities. Previous research identified saturation-excess runoff as the dominant runoff mechanism in this region. The Soil and Water Assessment Tool (SWAT) is a promising tool to simulate the NYC watershed given its broad application and good performance in many watersheds with different scales worldwide, for its ability to model water quality responses, and to evaluate the effect of management practices on water quality at the watershed scale. However, SWAT predicts runoff based mainly on soil and land use characteristics, and implicitly considers only infiltration-excess runoff. Therefore, we developed a modified version of SWAT, referred to as SWAT-Hillslope (SWAT-HS), which explicitly simulates saturation-excess runoff by redefining Hydrological Response Units (HRUs) based on wetness classes with varying soil water storage capacities, and by introducing a surface aquifer with the ability to route interflow from "drier" to "wetter" wetness classes. SWAT-HS was first tested at Town Brook, a 37 km2 headwater watershed draining to the Cannonsville reservoir using a single sub-basin for the whole watershed. SWAT-HS performed well, and predicted streamflow yielded Nash-Sutcliffe Efficiencies of 0.68 and 0.87 at the daily and monthly time steps, respectively. More importantly, it predicted the spatial distribution of saturated areas accurately. Based on the good performance in the Town Brook watershed, we scale-up the application of SWAT-HS to the 1160 km2 Cannonsville watershed utilizing a setup of multiple sub-basins, and evaluate the model performance on flow simulation at different gauged locations in the watershed. Results from flow predictions will be used as a basis for evaluating the ability of SWAT-HS to make sediment and nutrient loading estimates.
Cerebral Oxygen Saturation in Children With Congenital Heart Disease and Chronic Hypoxemia.
Kussman, Barry D; Laussen, Peter C; Benni, Paul B; McGowan, Francis X; McElhinney, Doff B
2017-07-01
Increased hemoglobin (Hb) concentration accompanying hypoxemia is a compensatory response to maintain tissue oxygen delivery. Near infrared spectroscopy (NIRS) is used clinically to detect abnormalities in the balance of cerebral tissue oxygen delivery and consumption, including in children with congenital heart disease (CHD). Although NIRS-measured cerebral tissue O2 saturation (ScO2) correlates with arterial oxygen saturation (SaO2), jugular bulb O2 saturation (SjbO2), and Hb, little data exist on the interplay between these factors and cerebral O2 extraction (COE). This study investigated the associations of ScO2 and ΔSaO2-ScO2 with SaO2 and Hb and verified the normal range of ScO2 in children with CHD. Children undergoing cardiac catheterization for CHD were enrolled in a calibration and validation study of the FORE-SIGHT NIRS monitor. Two pairs of simultaneous arterial and jugular bulb samples were drawn for co-oximetry, calculation of a reference ScO2 (REF CX), and estimation of COE. Pearson correlation and linear regression were used to determine relationships between O2 saturation parameters and Hb. Data were also analyzed according to diagnostic group defined as acyanotic (SaO2 ≥ 90%) and cyanotic (SaO2 < 90%). Of 65 children studied, acceptable jugular bulb samples (SjbO2 absolute difference between samples ≤10%) were obtained in 57 (88%). The ΔSaO2-SjbO2, ΔSaO2-ScO2, and ΔSaO2-REF CX were positively correlated with SaO2 and negatively correlated with Hb (all P < .001). Although by diagnostic group ScO2 differed statistically (P = .002), values in the cyanotic patients were within the range considered normal (69% ± 6%). COE estimated by the difference between arterial and jugular bulb O2 content (ΔCaO2-CjbO2, mL O2/100 mL) was not different for cyanotic and acyanotic patients (P = .10), but estimates using ΔSaO2-SjbO2, ΔSaO2-ScO2, or ΔSaO2-ScO2/SaO2 were significantly different between the cyanotic and acyanotic children (P < .001). Children with adequately compensated chronic hypoxemia appear to have ScO2 values within the normal range. The ΔSaO2-ScO2 is inversely related to Hb, with the implication that in the presence of reduced Hb, particularly if coupled with a decreased cardiac output, the ScO2 can fall to values associated with brain injury in laboratory studies.
Gai, Neville D; Malayeri, Ashkan A; Bluemke, David A
2017-04-01
To develop and assess a new technique for three-dimensional (3D) full lung T1 and T2* mapping using a single free breathing scan during a clinically feasible time. A 3D stack of dual-echo ultrashort echo time (UTE) radial acquisition interleaved with and without a WET (water suppression enhanced through T1 effects) saturation pulse was used to map T1 and T2* simultaneously in a single scan. Correction for modulation due to multiple views per segment was derived. Bloch simulations were performed to study saturation pulse excitation profile on lung tissue. Optimization of the saturation delay time (for T1 mapping) and echo time (for T2* mapping) was performed. Monte Carlo simulation was done to predict accuracy and precision of the sequence with signal-to-noise ratio of in vivo images used in the simulation. A phantom study was carried out using the 3D interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE) sequence and reference standard inversion recovery spin echo sequence (IR-SE) to compare accuracy of the sequence. Nine healthy volunteers were imaged and mean (SD) of T1 and T2* in lung parenchyma at 3T were estimated through manually assisted segmentation. 3D lung coverage with a resolution of 2.5 × 2.5 × 6 mm 3 was performed and nominal scan time was recorded for the scans. Repeatability was assessed in three of the volunteers. Regional differences in T1/T2* values were also assessed. The phantom study showed accuracy of T1 values to be within 2.3% of values obtained from IR-SE. Mean T1 value in lung parenchyma was 1002 ± 82 ms while T2* was 0.85 ± 0.1 ms. Scan time was ∼10 min for volunteer scans. Mean coefficient of variation (CV) across slices was 0.057 and 0.09, respectively. Regional variation along the gravitational direction and between right and left lung were not significant (P = 0.25 and P = 0.06, respectively) for T1. T2* showed significant variation (P = 0.03) along the gravitational direction. Repeatability for three volunteers was within 0.7% for T1 and 1.9% for T2*. 3D T1 and T2* maps of the entire lung can be obtained in a single scan of ∼10 min with a resolution of 2.5 × 2.5 × 6 mm 3 . 2 J. Magn. Reson. Imaging 2017;45:1097-1104. 2016 International Society for Magnetic Resonance in Medicine.
Response of Partially Saturated Non-cohesive Soils
NASA Astrophysics Data System (ADS)
Świdziński, Waldemar; Mierczyński, Jacek; Mikos, Agata
2017-12-01
This paper analyses and discusses experimental results of undrained triaxial tests. The tests were performed on non-cohesive partially saturated soil samples subjected to monotonic and cyclic loading. The tests were aimed at determining the influence of saturation degree on soil's undrained response (shear strength, excess pore pressure generation). The saturation of samples was monitored by checking Skempton's parameter B. Additionally, seismic P-wave velocity measurements were carried out on samples characterized by various degrees of saturation. The tests clearly showed that liquefaction may also take place in non-cohesive soils that are not fully saturated and that the liquefaction potential of such soils strongly depends on the B parameter.
Simulated effects of nitrogen saturation the global carbon budget using the IBIS model
Lu, Xuehe; Jiang, Hong; Liu, Jinxun; Zhang, Xiuying; Jin, Jiaxin; Zhu, Qiuan; Zhang, Zhen; Peng, Changhui
2016-01-01
Over the past 100 years, human activity has greatly changed the rate of atmospheric N (nitrogen) deposition in terrestrial ecosystems, resulting in N saturation in some regions of the world. The contribution of N saturation to the global carbon budget remains uncertain due to the complicated nature of C-N (carbon-nitrogen) interactions and diverse geography. Although N deposition is included in most terrestrial ecosystem models, the effect of N saturation is frequently overlooked. In this study, the IBIS (Integrated BIosphere Simulator) was used to simulate the global-scale effects of N saturation during the period 1961–2009. The results of this model indicate that N saturation reduced global NPP (Net Primary Productivity) and NEP (Net Ecosystem Productivity) by 0.26 and 0.03 Pg C yr−1, respectively. The negative effects of N saturation on carbon sequestration occurred primarily in temperate forests and grasslands. In response to elevated CO2 levels, global N turnover slowed due to increased biomass growth, resulting in a decline in soil mineral N. These changes in N cycling reduced the impact of N saturation on the global carbon budget. However, elevated N deposition in certain regions may further alter N saturation and C-N coupling.
Bhavsar, Nilam; St-Onge, Marie-Pierre
2016-03-01
The adverse cardiovascular health effects of saturated fats have been debated recently since the publication of studies reporting no increase in cardiovascular risk with saturated fat intakes. We purport that this may be because of the varied nature of saturated fats, which range in length from 2 to over 20 carbon atoms, and review evidence surrounding the cardiovascular health effects of medium-chain triglycerides (MCT). MCTs are saturated fats of shorter chain length than other, more readily consumed saturated fats. Studies have reported that consumption of MCT may lead to improvements in body composition without adversely affecting cardio-metabolic risk factors. There may also be synergistic actions between MCT and n-3 polyunsaturated fats that may lead to improvements in cardiovascular health. It is clinically relevant to distinguish between sources of saturated fats for cardiovascular health. Medium, and possibly shorter chain, saturated fats behave differently than long-chain saturated fats and should not be judged similarly when it comes to their cardio-metabolic health effects. Given their neutral, and potentially beneficial cardiovascular health effects, they should not be categorized together.
Water saturation effects on P-wave anisotropy in synthetic sandstone with aligned fractures
NASA Astrophysics Data System (ADS)
Amalokwu, Kelvin; Chapman, Mark; Best, Angus I.; Minshull, Timothy A.; Li, Xiang-Yang
2015-08-01
The seismic properties of rocks are known to be sensitive to partial liquid or gas saturation, and to aligned fractures. P-wave anisotropy is widely used for fracture characterization and is known to be sensitive to the saturating fluid. However, studies combining the effect of multiphase saturation and aligned fractures are limited even though such conditions are common in the subsurface. An understanding of the effects of partial liquid or gas saturation on P-wave anisotropy could help improve seismic characterization of fractured, gas bearing reservoirs. Using octagonal-shaped synthetic sandstone samples, one containing aligned penny-shaped fractures and the other without fractures, we examined the influence of water saturation on P-wave anisotropy in fractured rocks. In the fractured rock, the saturation related stiffening effect at higher water saturation values is larger in the direction across the fractures than along the fractures. Consequently, the anisotropy parameter `ε' decreases as a result of this fluid stiffening effect. These effects are frequency dependent as a result of wave-induced fluid flow mechanisms. Our observations can be explained by combining a frequency-dependent fractured rock model and a frequency-dependent partial saturation model.
NASA Astrophysics Data System (ADS)
Amalokwu, Kelvin; Chapman, Mark; Best, Angus I.; Sothcott, Jeremy; Minshull, Timothy A.; Li, Xiang-Yang
2015-01-01
Fractured rocks are known to exhibit seismic anisotropy and shear wave splitting (SWS). SWS is commonly used for fractured rock characterization and has been shown to be sensitive to fluid type. The presence of partial liquid/gas saturation is also known to affect the elastic properties of rocks. The combined effect of both fractures and partial liquid/gas saturation is still unknown. Using synthetic, silica-cemented sandstones with aligned penny-shaped voids, we conducted laboratory ultrasonic experiments to investigate the effect fractures aligned at an oblique angle to wave propagation would have on SWS under partial liquid/gas saturation conditions. The result for the fractured rock shows a saturation dependence which can be explained by combining a fractured rock model and a partial saturation model. At high to full water saturation values, SWS decreases as a result of the fluid bulk modulus effect on the quasi-shear wave. This bulk modulus effect is frequency dependent as a result of wave-induced fluid flow mechanisms, which would in turn lead to frequency dependent SWS. This result suggests the possible use of SWS for discriminating between full liquid saturation and partial liquid/gas saturation.
The Sounds of Desaturation: A Survey of Commercial Pulse Oximeter Sonifications.
Loeb, Robert G; Brecknell, Birgit; Sanderson, Penelope M
2016-05-01
The pulse oximeter has been a standard of care medical monitor for >25 years. Most manufacturers include a variable-pitch pulse tone in their pulse oximeters. Research has shown that the acoustic properties of variable-pitch tones are not standardized. In this study, we surveyed the properties of pulse tones from 21 pulse oximeters, consisting of 1 to 4 instruments of 11 different models and 8 brands. Our goals were to fully document the sounds over saturation values 0% to 100%, test whether tones become quieter at low saturation values, and create a public repository of pulse oximeter recordings for future use. A convenience sample of commercial pulse oximeters in use at one hospital was studied. Audiovisual recordings of each pulse oximeter's display and sounds were taken while it monitored a simulator starting at a saturation of 100% and slowly decreasing in 1% steps until the saturation reached 0%. Recorded pulse tones were analyzed for spectral frequency and total power. Audio files for each pulse oximeter containing 100 pulse tones, one at every saturation value, were created for inclusion in the repository. Recordings containing 509 to 1053 pulse tones were made from the 21 pulse oximeters. Fundamental frequencies at 100% saturation ranged from 479 to 921 Hz, and fundamental frequencies at 1% saturation ranged from 38 to 404 Hz. The pulse tones from all but one model pulse oximeter contained harmonics. Pulse tone step sizes were linear in 6 models and logarithmic in 6 models. Only 6 pulse oximeter models decreased the pulse tone pitch at every decrease in saturation; all others decreased the pitch at only select saturation thresholds. Five pulse oximeter models stopped decreasing pitch altogether once the saturation reached a certain lower threshold. Pulse tone power (perceived as loudness) changed with saturation level for all pulse oximeters, increasing above baseline as saturation decreased from 100% and decreasing to levels below baseline at low saturation values. Current pulse oximeters use different techniques to address the competing goals of (1) using pitch steps that are large enough to be readily perceived, and (2) conveying saturation values from 0 to 100 within a limited range of sound frequencies. From a clinical perspective, 2 techniques for increasing perceivability (increasing the frequency range and using ratio step sizes) have no drawback, but 2 techniques (not changing pitch at every saturation change and using a lower saturation cutoff) do have potential clinical drawbacks. On the basis of our findings, we have made suggestions for clinicians and manufacturers.
Schmidt, Barbara; Roberts, Robin S; Whyte, Robin K; Asztalos, Elizabeth V; Poets, Christian; Rabi, Yacov; Solimano, Alfonso; Nelson, Harvey
2014-10-01
To compare oxygen saturations as displayed to caregivers on offset pulse oximeters in the 2 groups of the Canadian Oxygen Trial. In 5 double-blind randomized trials of oxygen saturation targeting, displayed saturations between 88% and 92% were offset by 3% above or below the true values but returned to true values below 84% and above 96%. During the transition, displayed values remained static at 96% in the lower and at 84% in the higher target group during a 3% change in true saturations. In contrast, displayed values changed rapidly from 88% to 84% in the lower and from 92% to 96% in the higher target group during a 1% change in true saturations. We plotted the distributions of median displayed saturations on days with >12 hours of supplemental oxygen in 1075 Canadian Oxygen Trial participants to reconstruct what caregivers observed at the bedside. The oximeter masking algorithm was associated with an increase in both stability and instability of displayed saturations that occurred during the transition between offset and true displayed values at opposite ends of the 2 target ranges. Caregivers maintained saturations at lower displayed values in the higher than in the lower target group. This differential management reduced the separation between the median true saturations in the 2 groups by approximately 3.5%. The design of the oximeter masking algorithm may have contributed to the smaller-than-expected separation between true saturations in the 2 study groups of recent saturation targeting trials in extremely preterm infants. Copyright © 2014 Elsevier Inc. All rights reserved.
The distribution of saturated clusters in wetted granular materials
NASA Astrophysics Data System (ADS)
Li, Shuoqi; Hanaor, Dorian; Gan, Yixiang
2017-06-01
The hydro-mechanical behaviour of partially saturated granular materials is greatly influenced by the spatial and temporal distribution of liquid within the media. The aim of this paper is to characterise the distribution of saturated clusters in granular materials using an optical imaging method under different water drainage conditions. A saturated cluster is formed when a liquid phase fully occupies the pore space between solid grains in a localized region. The samples considered here were prepared by vibrating mono-sized glass beads to form closely packed assemblies in a rectangular container. A range of drainage conditions were applied to the specimen by tilting the container and employing different flow rates, and the liquid pressure was recorded at different positions in the experimental cell. The formation of saturated clusters during the liquid withdrawal processes is governed by three competing mechanisms arising from viscous, capillary, and gravitational forces. When the flow rate is sufficiently large and the gravity component is sufficiently small, the viscous force tends to destabilize the liquid front leading to the formation of narrow fingers of saturated material. As the water channels along these liquid fingers break, saturated clusters are formed inside the specimen. Subsequently, a spatial and temporal distribution of saturated clusters can be observed. We investigated the resulting saturated cluster distribution as a function of flow rate and gravity to achieve a fundamental understanding of the formation and evolution of such clusters in partially saturated granular materials. This study serves as a bridge between pore-scale behavior and the overall hydro-mechanical characteristics in partially saturated soils.
Kaizer, Rosilene Rodrigues; Spanevello, Rosélia Maria; Costa, Eduarda; Morsch, Vera Maria; Schetinger, Maria Rosa Chitolina
2018-02-01
High fat diets are associated with the promotion of neurological diseases, such as Alzheimer disease (AD). This study aim investigate the high fat diets role to promotion of AD using as biochemistry parameter of status of central nervous system through the NTPDase, 5'-nucleotidase and acetylcholinesterase (AChE) activities in brain of young rats. The intake of high fat diets promotes an inhibition of purinergic and cholinergic functions, mainly in the long-term exposure to saturated and saturated/unsaturated diets. The AChE activity was decreased to supernatant and synaptosomes tissues preparations obtained from cerebral cortex in average of 20%, to both groups exposed to saturated and saturated/unsaturated diets, when compared to the control group. Very similar results were found in hippocampus and cerebellum brain areas. At same time, the adenine nucleotides hydrolysis in synaptosomes of cerebral cortex were decreased to ATP, ADP and AMP after the long-term exposure to high fat diets, as saturated and saturated/unsaturated. The inhibition of ATP hydrolysis was of 26% and 39% to saturated and saturated/unsaturated diets, respectively. ADP hydrolysis was decreased in 20% to saturated diet, and AMP hydrolysis was decreased in 25% and 33% to saturated and saturated/unsaturated diets, respectively, all in comparison to the control. Thus, we can suggest that the effects of high diets on the purinergic and cholinergic nervous system may contribute to accelerate the progressive memory loss, to decline in language and other cognitive disruptions, such as AD patients presents. Copyright © 2017 ISDN. Published by Elsevier Ltd. All rights reserved.
Streaming Potential In Rocks Saturated With Water And Oil
NASA Astrophysics Data System (ADS)
Tarvin, J. A.; Caston, A.
2011-12-01
Fluids flowing through porous media generate electrical currents. These currents cause electric potentials, called "streaming potentials." Streaming potential amplitude depends on the applied pressure gradient, on rock and fluid properties, and on the interaction between rock and fluid. Streaming potential has been measured for rocks saturated with water (1) and with water-gas mixtures. (2) Few measurements (3) have been reported for rocks saturated with water-oil mixtures. We measured streaming potential for sandstone and limestone saturated with a mixture of brine and laboratory oil. Cylindrical samples were initially saturated with brine and submerged in oil. Saturation was changed by pumping oil from one end of a sample to the other and then through the sample in the opposite direction. Saturation was estimated from sample resistivity. The final saturation of each sample was determined by heating the sample in a closed container and measuring the pressure. Measurements were made by modulating the pressure difference (of oil) between the ends of a sample at multiple frequencies below 20 Hz. The observed streaming potential is a weak function of the saturation. Since sample conductivity decreases with increasing oil saturation, the electro-kinetic coupling coefficient (Pride's L (4)) decreases with increasing oil saturation. (1) David B. Pengra and Po-zen Wong, Colloids and Surfaces, vol., p. 159 283-292 (1999). (2) Eve S. Sprunt, Tony B. Mercer, and Nizar F. Djabbarah, Geophysics, vol. 59, p. 707-711 (1994). (3) Vinogradov, J., Jackson, M.D., Geophysical Res. L., Vol. 38, Article L01301 (2011). (4) Steve Pride, Phys. Rev. B, vol. 50, pp. 15678-15696 (1994).
A demonstration experiment for studying the properties of saturated vapor
NASA Astrophysics Data System (ADS)
Grebenev, Igor V.; Lebedeva, Olga V.; Polushkina, Svetlana V.
2017-11-01
The paper proposes an important demonstration experiment that can be used at secondary schools in physics. The described experiment helps students learn the main concepts of the topic ‘saturated vapor’, namely, evaporation, condensation, dynamic equilibrium, saturation vapor, partial pressure, and the dependence of saturated vapor pressure on temperature.
CORE SATURATION BLOCKING OSCILLATOR
Spinrad, R.J.
1961-10-17
A blocking oscillator which relies on core saturation regulation to control the output pulse width is described. In this arrangement an external magnetic loop is provided in which a saturable portion forms the core of a feedback transformer used with the thermionic or semi-conductor active element. A first stationary magnetic loop establishes a level of flux through the saturation portion of the loop. A second adjustable magnet moves the flux level to select a saturation point giving the desired output pulse width. (AEC)
NASA Astrophysics Data System (ADS)
Kassem Jebai, Al; Malrait, François; Martin, Philippe; Rouchon, Pierre
2016-03-01
Sensorless control of permanent-magnet synchronous motors at low velocity remains a challenging task. A now well-established method consists of injecting a high-frequency signal and using the rotor saliency, both geometric and magnetic-saturation induced. This paper proposes a clear and original analysis based on second-order averaging of how to recover the position information from signal injection; this analysis blends well with a general model of magnetic saturation. It also proposes a simple parametric model of the saturated motor, based on an energy function which simply encompasses saturation and cross-saturation effects. Experimental results on a surface-mounted motor and an interior magnet motor illustrate the relevance of the approach.
Increased Carbonic Anhydrase Activity is Associated with Sleep Apnea Severity and Related Hypoxemia
Wang, Tengyu; Eskandari, Davoud; Zou, Ding; Grote, Ludger; Hedner, Jan
2015-01-01
Study Objectives: The catalytic function of the enzyme carbonic anhydrase (CA) plays a fundamental role in carbon dioxide (CO2), proton (H+), and bicarbonate (HCO3-) homeostasis. Hypoxia and tissue acidosis have been proposed to increase physiological CA activity in various compartments of the body. We hypothesized that CA activity in blood is upregulated in patients with obstructive sleep apnea (OSA). Design: Cross-sectional analysis of a sleep clinic cohort. Settings: Sleep laboratory at a university hospital. Participants: Seventy referred patients with suspected OSA (48 males, age 54 ± 13 y, apnea-hypopnea index (AHI) median [interquartile range] 21 [8–41] n/h). Interventions: N/A. Measurements and Results: In-laboratory cardiorespiratory polygraphy was used to assess OSA. CA activity was determined by an in vitro assay that quantifies the pH change reflecting the conversion of CO2 and H2O to HCO3- and H+. CA activity was positively associated with AHI and 4% oxygen desaturation index (ODI4) (Spearman correlation r = 0.44 and 0.47, both P < 0.001). The associations (CA activity versus logAHI and CA versus logODI4) were independent of sex, age, body mass index, presleep oxygen saturation, nocturnal oxygen saturation, hypertension status, and use of diuretic medication in two generalized linear models (P = 0.007 and 0.011, respectively). Sitting diastolic blood pressure was associated with CA activity after adjustment of sex, age, body mass index, mean oxygen saturation, and AHI (P = 0.046). Conclusions: Carbonic anhydrase (CA) activity increased with apnea-hypopnea index and related nocturnal hypoxemia measures in patients with obstructive sleep apnea (OSA). Altered CA activity may constitute a component that modulates respiratory control and hemodynamic regulation in patients with OSA. Citation: Wang T, Eskandari D, Zou D, Grote L, Hedner J. Increased carbonic anhydrase activity is associated with sleep apnea severity and related hypoxemia. SLEEP 2015;38(7):1067–1073. PMID:25845687
Potential contributions of smectite clays and organic matter to pesticide retention in soils.
Sheng, G; Johnston, C T; Teppen, B J; Boyd, S A
2001-06-01
Soil organic matter (SOM) is often considered the dominant sorptive phase for organic contaminants and pesticides in soil-water systems. This is evidenced by the widespread use of organic-matter-normalized sorption coefficients (K(OM)) to predict soil-water distribution of pesticides, an approach that ignores the potential contribution of soil minerals to sorption. To gain additional perspective on the potential contributions of clays and SOM to pesticide retention in soils, we measured sorption of seven pesticides by a K-saturated reference smectite clay (SWy-2) and SOM (represented by a muck soil). In addition, we measured the adsorption of atrazine by five different K-saturated smectites and Ca-saturated SWy-2. On a unit mass basis, the K-SWy-2 clay was a more effective sorbent than SOM for 4,6-dinitro-o-cresol (DNOC), dichlobenil, and carbaryl of the seven pesticides evaluated, of which, DNOC was sorbed to the greatest extent. Atrazine was sorbed to a similar extent by K-SWy-2 and SOM. Parathion, diuron, and biphenyl were sorbed to a greater extent by SOM than by K-SWy-2. Atrazine was adsorbed by Ca-SWy-2 to a much lesser extent than by K-SWy-2. This appears to be related to the larger hydration sphere of Ca(2+) (compared to that of K(+)) which shrinks the effective size of the adsorption domains between exchangeable cations, and which expands the clay layers beyond the apparently optimal spacing of approximately 12.2 A for sorption of aromatic pesticide structures. Although a simple relation between atrazine adsorption by different K-smectites and charge properties of clay was not observed, the highest charge clay was the least effective sorbent; a higher charge density would result in a loss of adsorption domains. These results indicate that for certain pesticides, expandable soil clays have the potential to be an equal or dominant sorptive phase when compared to SOM for pesticide retention in soil.
Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D
2018-01-01
Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P < 0.001). The INVOS 5100C bias was also lower during normocapnia (5 ± 15% vs. 3 ± 12%; P = 0.01). Hypocapnia resulted in a significant decrease in mixed venous oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P < 0.0001). Bias increased significantly with increasing oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.
Power flow control using distributed saturable reactors
Dimitrovski, Aleksandar D.
2016-02-13
A magnetic amplifier includes a saturable core having a plurality of legs. Control windings wound around separate legs are spaced apart from each other and connected in series in an anti-symmetric relation. The control windings are configured in such a way that a biasing magnetic flux arising from a control current flowing through one of the plurality of control windings is substantially equal to the biasing magnetic flux flowing into a second of the plurality of control windings. The flow of the control current through each of the plurality of control windings changes the reactance of the saturable core reactor by driving those portions of the saturable core that convey the biasing magnetic flux in the saturable core into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the saturable core.
NASA Astrophysics Data System (ADS)
Lee, T. J.; Lee, K. S., , Dr; Lee, S. K.
2017-12-01
One of the most important factors in measuring effective porosity by vacuum saturation method is that the air in the pore space can be fully substituted by water during the vacuum saturation process. International Society of Rock Mechanics (ISRM) suggests vacuuming a rock sample submerged in the water, while American Society of Test and Materials (ASTM) vacuuming the sample and water separately and then pour the water to the sample. In this study, we call the former wet-type vacuum saturation (WVS) method and the latter dry-type vacuum saturation (DVS) method, and compare the effective porosity measured by the two different vacuum saturation processes. For that purpose, a vacuum saturation system has been developed, which can support both WVS and DVS by only changing the process by programming. Comparison of effective porosity has been made for a cement mortar and rock samples. As a result, DVS can substitute more void volume to water than WVS, which in turn insists that DVS can provide more exact value of effective porosity than WVS.
Rath, Chandra; Kluckow, Martin
2016-03-01
Compare the oxygen saturation profiles before discharge of neonates born extremely preterm (<28 weeks), now at term equivalent age, with healthy term neonates and assess the impact of feeding on this profile in each group. We prospectively evaluated and compared the oxygen saturation profile in 15 very low birthweight infants at term equivalent age, ready to be discharged home without any oxygen and 15 term newborns after 48 hours of life. We also evaluated and compared the saturations of these two groups during a one-hour period during and after feeding. Term equivalent preterm and term infants spent median 3% and 0%, respectively, of the time below 90% in a 12-hour saturation-recording period. Term infants spent a median 0.26% and 0.65% of the time in <90% saturation during feed time and no feed time, respectively. In contrast, preterm infants spent significantly more time <90% saturation (3.47% and 3.5% during feed time and no feed time, respectively). Term equivalent preterm infants spent significantly more time in a saturation range <90% compared to term infants. Feeding had little effect on saturation profile overall within each group. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Xiao, Kun; Zou, Changchun; Xiang, Biao; Liu, Jieqiong
2013-01-01
Gas hydrate model and free gas model are established, and two-phase theory (TPT) for numerical simulation of elastic wave velocity is adopted to investigate the unconsolidated deep-water sedimentary strata in Shenhu area, South China Sea. The relationships between compression wave (P wave) velocity and gas hydrate saturation, free gas saturation, and sediment porosity at site SH2 are studied, respectively, and gas hydrate saturation of research area is estimated by gas hydrate model. In depth of 50 to 245 m below seafloor (mbsf), as sediment porosity decreases, P wave velocity increases gradually; as gas hydrate saturation increases, P wave velocity increases gradually; as free gas saturation increases, P wave velocity decreases. This rule is almost consistent with the previous research result. In depth of 195 to 220 mbsf, the actual measurement of P wave velocity increases significantly relative to the P wave velocity of saturated water modeling, and this layer is determined to be rich in gas hydrate. The average value of gas hydrate saturation estimated from the TPT model is 23.2%, and the maximum saturation is 31.5%, which is basically in accordance with simplified three-phase equation (STPE), effective medium theory (EMT), resistivity log (Rt), and chloride anomaly method. PMID:23935407
Simulated effects of nitrogen saturation on the global carbon budget using the IBIS model
Lu, Xuehe; Jiang, Hong; Liu, Jinxun; Zhang, Xiuying; Jin, Jiaxin; Zhu, Qiuan; Zhang, Zhen; Peng, Changhui
2016-01-01
Over the past 100 years, human activity has greatly changed the rate of atmospheric N (nitrogen) deposition in terrestrial ecosystems, resulting in N saturation in some regions of the world. The contribution of N saturation to the global carbon budget remains uncertain due to the complicated nature of C-N (carbon-nitrogen) interactions and diverse geography. Although N deposition is included in most terrestrial ecosystem models, the effect of N saturation is frequently overlooked. In this study, the IBIS (Integrated BIosphere Simulator) was used to simulate the global-scale effects of N saturation during the period 1961–2009. The results of this model indicate that N saturation reduced global NPP (Net Primary Productivity) and NEP (Net Ecosystem Productivity) by 0.26 and 0.03 Pg C yr−1, respectively. The negative effects of N saturation on carbon sequestration occurred primarily in temperate forests and grasslands. In response to elevated CO2 levels, global N turnover slowed due to increased biomass growth, resulting in a decline in soil mineral N. These changes in N cycling reduced the impact of N saturation on the global carbon budget. However, elevated N deposition in certain regions may further alter N saturation and C-N coupling. PMID:27966643
Miguel, E; Güell, R; Antón, A; Montiel, J A; Mayos, M
2004-06-01
Acute confusional syndrome, or delirium, is a transitory mental state characterized by the fluctuating alteration of awareness and attention levels. We present the case of a patient with acute confusional syndrome associated with obstructive sleep apnea syndrome (OSAS) aggravated by metabolic acidosis induced by oral acetazolamide treatment.A 70-year-old man with no history of neurological disease was referred with a clinical picture consistent with acute confusional syndrome presenting between midnight and dawn. During the admission examination infectious, toxic, and neurologic causes, or those related to metabolic or heart disease were ruled out. Arterial blood gases measured during one of the nighttime episodes of acute confusional syndrome showed mild hypoxia and hypercapnia with mixed acidosis. Signs and symptoms suggestive of OSAS had been developing over the months prior to admission, with snoring, sleep apnea, and moderate daytime drowsiness. Polysomnography demonstrated severe OSAS with an apnea-hypopnea index of 38. Mean arterial oxygen saturation was 83%; time oxygen saturation remained below 90% was 44%. The attending physician ordered the withdrawal of oral acetazolamide, which was considered the cause of the metabolic component of acidosis. Treatment with continuous positive airway pressure was initiated at 9 cm H2O, after a titration polysomnographic study. The patient continued to improve.OSAS, for which very effective treatment is available, should be included among diseases that may trigger acute confusional syndrome.
Cummings, James J.; Lakshminrusimha, Satyan
2017-01-01
Purpose of review A collaboration of comparative effectiveness research trials of pulse oximeter saturation (SpO2) targeting in extremely low gestational age neonates (ELGANs) have begun to report their aggregate results. We will examine the results of those trials, collectively referred to as the Neonatal Oxygenation Prospective Meta-analysis, or NeOProM. We will also discuss the uncertainties that remain and the clinical challenges that lie ahead. Recent findings The primary outcome from NeOProM was a composite of death or disability at 18–24 months corrected age. Earlier this year, the last of these reports was published. Although there were no differences in the primary outcome overall, analyses of secondary outcomes and data subsets following a pulse oximeter revision show significant treatment differences between targeting a lower compared to a higher SpO2. Summary NeOProM represents the largest collaborative clinical research study of SpO2 targets in ELGANs. While aggregate results give us some insight into the feasibility and efficacy of SpO2 targeting in this population, many questions remain. A patient-level analysis, tracking individual outcomes based on actual SpO2 experienced, may shed some light on these questions. However, finding a single optimal SpO2 range seems unlikely. PMID:28085683
Temperature dependence and GABA modulation of (TH)triazolam binding in the rat brain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Earle, M.E.; Concas, A.; Wamsley, J.K.
1987-07-27
The hypnotic triazolam (TZ), a triazolobenzodiazepine displays a short physiological half life and has been used for the treatment of insomnia related to anxiety states. The authors major objectives were the direct measurement of the temperature dependence and the gamma-aminobutyric acid (GABA) effect of (TH)TZ binding in the rat brain. Saturation studies showed a shift to lower affinity with increasing temperatures (K/sub d/ = 0.27 +/- 08 nM at 0C; K/sub d/ = 1.96 +/- 0.85 nM at 37C) while the B/sub max/ values remained unchanged (1220 +/- 176 fmoles/mg protein at 0C and 1160 +/- 383 fmoles/mg protein atmore » 37C). Saturation studies of (TH)TZ binding in the presence or absence of GABA (100 M) showed a GABA-shift. At 0C the K/sub d/ values were (K/sub d/ = 0.24 +/- 0.03 nM/-GABA; K/sub d/ = 0.16 +/- 0.04/+GABA) and at 37C the K/sub d/ values were (K/sub d/ = 1.84 +/- 0.44 nM/-GABA; K/sub d/ = 0.95 +/- 0.29 nM/+GABA). In contrast to reported literature, the authors findings show that TZ interacts with benzodiazepine receptors with a temperature dependence and GABA-shift consistent with predicted behavior for benzodiazepine agonists. 20 references, 3 tables.« less
Precision Saturated Absorption Spectroscopy of H3+
NASA Astrophysics Data System (ADS)
Guan, Yu-chan; Liao, Yi-Chieh; Chang, Yung-Hsiang; Peng, Jin-Long; Shy, Jow-Tsong
2016-06-01
In our previous work on the Lamb dips of the νb{2} fundamental band of H3+, the saturated absorption spectrum was obtained by the third-derivative spectroscopy using frequency modulation [1]. However, the frequency modulation also causes error in absolute frequency determination. To solve this problem, we have built an offset-locking system to lock the OPO pump frequency to an iodine-stabilized Nd:YAG laser. With this modification, we are able to scan the OPO idler frequency precisely and obtain the profile of the Lamb dips. Double modulation (amplitude modulation of the idler power and concentration modulation of the ion) is employed to subtract the interference fringes of the signal and increase the signal-to-noise ratio effectively. To Determine the absolute frequency of the idler wave, the pump wave is offset locked on the R(56) 32-0 a10 hyperfine component of 127I2, and the signal wave is locked on a GPS disciplined fiber optical frequency comb (OFC). All references and lock systems have absolute frequency accuracy better than 10 kHz. Here, we demonstrate its performance by measuring one transition of methane and sixteen transitions of H3+. This instrument could pave the way for the high-resolution spectroscopy of a variety of molecular ions. [1] H.-C. Chen, C.-Y. Hsiao, J.-L. Peng, T. Amano, and J.-T. Shy, Phys. Rev. Lett. 109, 263002 (2012).
Harnessing color vision for visual oximetry in central cyanosis.
Changizi, Mark; Rio, Kevin
2010-01-01
Central cyanosis refers to a bluish discoloration of the skin, lips, tongue, nails, and mucous membranes, and is due to poor arterial oxygenation. Although skin color is one of its characteristic properties, it has long been realized that by the time skin color signs become visible, oxygen saturation is dangerously low. Here we investigate the visibility of cyanosis in light of recent discoveries on what color vision evolved for in primates. We elucidate why low arterial oxygenation is visible at all, why it is perceived as blue, and why it can be so difficult to perceive. With a better understanding of the relationship between color vision and blood physiology, we suggest two simple techniques for greatly enhancing the clinician's ability to detect cyanosis and other clinical color changes. The first is called "skin-tone adaptation", wherein sheets, gowns, walls and other materials near a patient have a color close to that of the patient's skin, thereby optimizing a color-normal viewer's ability to sense skin color modulations. The second technique is called "biosensor color tabs", wherein adhesive tabs with a color matching the patient's skin tone are placed in several spots on the skin, and subsequent skin color changes have the effect of making the initially-invisible tabs change color, their hue and saturation indicating the direction and magnitude of the skin color shift.
Revisiting Theories of Humidity Transduction: A Focus on Electrophysiological Data.
Tichy, Harald; Hellwig, Maria; Kallina, Wolfgang
2017-01-01
Understanding the mechanism of humidity transduction calls for experimental data and a theory to interpret the data and design new experiments. A comprehensive theory of humidity transduction must start with agreement on what humidity parameters are measured by hygroreceptors and processed by the brain. Hygroreceptors have been found in cuticular sensilla of a broad range of insect species. Their structural features are far from uniform. Nevertheless, these sensilla always contain an antagonistic pair of a moist cell and a dry cell combined with a thermoreceptive cold cell. The strategy behind this arrangement remains unclear. Three main models of humidity transduction have been proposed. Hygroreceptors could operate as mechanical hygrometers, psychrometers or evaporation detectors. Each mode of action measures a different humidity parameter. Mechanical hygrometers measure the relative humidity, psychrometers indicate the wet-bulb temperature, and evaporimeters refer to the saturation deficit of the air. Here we assess the validity of the different functions by testing specific predictions drawn from each of the models. The effect of air temperature on the responses to humidity stimulation rules out the mechanical hygrometer function, but it supports the psychrometer function and highlights the action as evaporation rate detector. We suggest testing the effect of the flow rate of the air stream used for humidity stimulation. As the wind speed strongly affects the power of evaporation, experiments with changing saturation deficit at different flow rates would improve our knowledge on humidity transduction.
1987 Robert E. Horton Award to Thomas Dunne
NASA Astrophysics Data System (ADS)
Dunne, Thomas
Robert Horton demonstrated in his seminal 1945 paper that physically based quantitative models for landscape evolution can be constructed by using predicted overland flow in a sediment transport equation for sheetwash. He envisioned drainage network evolution by infiltration-limited overland flow as a process of channel incision, network growth, and then abstraction to a stable channel network fed by hillslopes too short for channel initiation. Not until the work of Tom Dunne in the late 1960s in the Sleepers River watershed, Vermont, was it realized that overland flow, and consequently hillslope evolution, could occur by an entirely different mechanism than that proposed by Horton. Dunne showed that in certain predictable zones of the landscape, exfiltration from saturated grounds adds to precipitation on the soil surface to form what he later called saturation overland flow. Many researchers have since found that this form of overland flow occurs in humid and semiarid landscapes throughout the world. So clear is Dunne's contribution to defining this process that some refer to it as the “Dunne mechanism” to distinguish it from “Horton overland flow.” His work also documented unquestionably the applicability of the partial area concept in explaining runoff generation. Because of this work, his research in snowmelt runoff, and his subsequent authorship with Luna Leopold of the widely used book entitled Water in Environmental Planning, Dunne has established himself as a leader of process hydrology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leppäniemi, J., E-mail: jaakko.leppaniemi@vtt.fi; Ojanperä, K.; Kololuoma, T.
We propose a combined far ultraviolet (FUV) and thermal annealing method of metal-nitrate-based precursor solutions that allows efficient conversion of the precursor to metal-oxide semiconductor (indium zinc oxide, IZO, and indium oxide, In{sub 2}O{sub 3}) both at low-temperature and in short processing time. The combined annealing method enables a reduction of more than 100 °C in annealing temperature when compared to thermally annealed reference thin-film transistor (TFT) devices of similar performance. Amorphous IZO films annealed at 250 °C with FUV for 5 min yield enhancement-mode TFTs with saturation mobility of ∼1 cm{sup 2}/(V·s). Amorphous In{sub 2}O{sub 3} films annealed for 15 min with FUV atmore » temperatures of 180 °C and 200 °C yield TFTs with low-hysteresis and saturation mobility of 3.2 cm{sup 2}/(V·s) and 7.5 cm{sup 2}/(V·s), respectively. The precursor condensation process is clarified with x-ray photoelectron spectroscopy measurements. Introducing the FUV irradiation at 160 nm expedites the condensation process via in situ hydroxyl radical generation that results in the rapid formation of a continuous metal-oxygen-metal structure in the film. The results of this paper are relevant in order to upscale printed electronics fabrication to production-scale roll-to-roll environments.« less
Sadala, S P; Patre, B M
2018-03-01
The 2-degree of freedom (DOF) helicopter system is a typical higher-order, multi-variable, nonlinear and strong coupled control system. The helicopter dynamics also includes parametric uncertainties and is subject to unknown external disturbances. Such complicated system requires designing a sophisticated control algorithm that can handle these difficulties. This paper presents a new robust control algorithm which is a combination of two continuous control techniques, composite nonlinear feedback (CNF) and super-twisting control (STC) methods. In the existing integral sliding mode (ISM) based CNF control law, the discontinuous term exhibits chattering which is not desirable for many practical applications. As the continuity of well known STC reduces chattering in the system, the proposed strategy is beneficial over the current ISM based CNF control law which has a discontinuous term. Two controllers with integral sliding surface are designed to control the position of the pitch and the yaw angles of the 2- DOF helicopter. The adequacy of this specific combination has been exhibited through general analysis, simulation and experimental results of 2-DOF helicopter setup. The acquired results demonstrate the good execution of the proposed controller regarding stabilization, following reference input without overshoot against actuator saturation and robustness concerning to the limited matched disturbances. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS).
Bertelsen, Mads F; Grøndahl, Carsten; Stegmann, George F; Sauer, Cathrine; Secher, Niels H; Hasenkam, J Michael; Damkjær, Mads; Aalkjær, Christian; Wang, Tobias
2017-09-01
This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
Fragrance material review on 16-hydroxy-7-hexadecenoic acid lactone.
McGinty, D; Letizia, C S; Api, A M
2011-12-01
A toxicologic and dermatologic review of 16-hydroxy-7-hexadecenoic acid lactone when used as a fragrance ingredient is presented. 16-Hydroxy-7-hexadecenoic acid lactone is a member of the fragrance structural group macrocyclic lactone and lactide derivatives. The fragrance ingredient described herein is one of 12 structurally diverse C14, C15 and C16 compounds that include (1) saturated mono-and (2) saturated di-ester lactones and (3) unsaturated lactones. For the latter, the double bond is not adjacent to (in conjugation with) the ester group. This review contains a detailed summary of all available toxicology and dermatology papers that are related to 16-hydroxy-7-hexadecenoic acid lactone and is not intended as a stand-alone document. Available data were evaluated, then summarized, and include physical properties data. A safety assessment of the entire macrocyclic lactone and lactide derivatives will be published simultaneously with this document. Please refer to Belsito et al., 2011 for an overall assessment of the safe use of this material and all macrocyclic lactone and lactide derivatives in fragrances. Belsito, D., Bickers, D., Bruze, M., Calow, P., Dagli, M., Fryer, A.D., Greim, H., Hanifin, J.H., Miyachi, Y., Saurat, J.H., Sipes, I.G., 2011. A toxicologic and dermatologic assessment of macrocylic lactones and lactide derivatives when used as fragrance ingredients. Copyright © 2011. Published by Elsevier Ltd.
LEOPARD: A grid-based dispersion relation solver for arbitrary gyrotropic distributions
NASA Astrophysics Data System (ADS)
Astfalk, Patrick; Jenko, Frank
2017-01-01
Particle velocity distributions measured in collisionless space plasmas often show strong deviations from idealized model distributions. Despite this observational evidence, linear wave analysis in space plasma environments such as the solar wind or Earth's magnetosphere is still mainly carried out using dispersion relation solvers based on Maxwellians or other parametric models. To enable a more realistic analysis, we present the new grid-based kinetic dispersion relation solver LEOPARD (Linear Electromagnetic Oscillations in Plasmas with Arbitrary Rotationally-symmetric Distributions) which no longer requires prescribed model distributions but allows for arbitrary gyrotropic distribution functions. In this work, we discuss the underlying numerical scheme of the code and we show a few exemplary benchmarks. Furthermore, we demonstrate a first application of LEOPARD to ion distribution data obtained from hybrid simulations. In particular, we show that in the saturation stage of the parallel fire hose instability, the deformation of the initial bi-Maxwellian distribution invalidates the use of standard dispersion relation solvers. A linear solver based on bi-Maxwellians predicts further growth even after saturation, while LEOPARD correctly indicates vanishing growth rates. We also discuss how this complies with former studies on the validity of quasilinear theory for the resonant fire hose. In the end, we briefly comment on the role of LEOPARD in directly analyzing spacecraft data, and we refer to an upcoming paper which demonstrates a first application of that kind.
Hydrate morphology: Physical properties of sands with patchy hydrate saturation
Dai, S.; Santamarina, J.C.; Waite, William F.; Kneafsey, T.J.
2012-01-01
The physical properties of gas hydrate-bearing sediments depend on the volume fraction and spatial distribution of the hydrate phase. The host sediment grain size and the state of effective stress determine the hydrate morphology in sediments; this information can be used to significantly constrain estimates of the physical properties of hydrate-bearing sediments, including the coarse-grained sands subjected to high effective stress that are of interest as potential energy resources. Reported data and physical analyses suggest hydrate-bearing sands contain a heterogeneous, patchy hydrate distribution, whereby zones with 100% pore-space hydrate saturation are embedded in hydrate-free sand. Accounting for patchy rather than homogeneous hydrate distribution yields more tightly constrained estimates of physical properties in hydrate-bearing sands and captures observed physical-property dependencies on hydrate saturation. For example, numerical modeling results of sands with patchy saturation agree with experimental observation, showing a transition in stiffness starting near the series bound at low hydrate saturations but moving toward the parallel bound at high hydrate saturations. The hydrate-patch size itself impacts the physical properties of hydrate-bearing sediments; for example, at constant hydrate saturation, we find that conductivity (electrical, hydraulic and thermal) increases as the number of hydrate-saturated patches increases. This increase reflects the larger number of conductive flow paths that exist in specimens with many small hydrate-saturated patches in comparison to specimens in which a few large hydrate saturated patches can block flow over a significant cross-section of the specimen.
Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter
Johnston, Ewen D; Boyle, Breidge; Juszczak, Ed; King, Andy; Brocklehurst, Peter; Stenson, Ben J
2011-01-01
Background A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter. Methods Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies. Results There was a reduction in saturation values of 87–90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions. Conclusions A characteristic of the software algorithm reduces the frequency of saturations of 87–90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability. PMID:21378398
Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter.
Johnston, Ewen D; Boyle, Breidge; Juszczak, Ed; King, Andy; Brocklehurst, Peter; Stenson, Ben J
2011-11-01
A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter. Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies. There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions. A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.
Low-loss saturable absorbers based on tapered fibers embedded in carbon nanotube/polymer composites
NASA Astrophysics Data System (ADS)
Martinez, Amos; Al Araimi, Mohammed; Dmitriev, Artemiy; Lutsyk, Petro; Li, Shen; Mou, Chengbo; Rozhin, Alexey; Sumetsky, Misha; Turitsyn, Sergei
2017-12-01
The emergence of low-dimensional materials has opened new opportunities in the fabrication of compact nonlinear photonic devices. Single-walled carbon nanotubes were among the first of those materials to attract the attention of the photonics community owing to their high third order susceptibility, broadband operation, and ultrafast response. Saturable absorption, in particular, has become a widespread application for nanotubes in the mode-locking of a fiber laser where they are used as nonlinear passive amplitude modulators to initiate pulsed operation. Numerous approaches have been proposed for the integration of nanotubes in fiber systems; these can be divided into those that rely on direct interaction (where the nanotubes are sandwiched between fiber connectors) and those that rely on lateral interaction with the evanescence field of the propagating wave. Tapered fibers, in particular, offer excellent flexibility to adjust the nonlinearity of nanotube-based devices but suffer from high losses (typically exceeding 50%) and poor saturable to non-saturable absorption ratios (typically above 1:5). In this paper, we propose a method to fabricate carbon nanotube saturable absorbers with controllable saturation power, low-losses (as low as 15%), and large saturable to non-saturable loss ratios approaching 1:1. This is achieved by optimizing the procedure of embedding tapered fibers in low-refractive index polymers. In addition, this study sheds light in the operation of these devices, highlighting a trade-off between losses and saturation power and providing guidelines for the design of saturable absorbers according to their application.
Gochicoa-Rangel, Laura; Pérez-Padilla, José Rogelio; Rodríguez-Moreno, Luis; Montero-Matamoros, Arturo; Ojeda-Luna, Nancy; Martínez-Carbajal, Gema; Hernández-Raygoza, Roberto; Ruiz-Pedraza, Dolores; Fernández-Plata, María Rosario; Torre-Bouscoulet, Luis
2015-01-01
Altitude above sea level and body mass index are well-recognized determinants of oxygen saturation in adult populations; however, the contribution of these factors to oxygen saturation in children is less clear. To explore the contribution of altitude above sea level and body mass index to oxygen saturation in children. A multi-center, cross-sectional study conducted in nine cities in Mexico. Parents signed informed consent forms and completed a health status questionnaire. Height, weight, and pulse oximetry were recorded. We studied 2,200 subjects (52% girls) aged 8.7 ± 3.0 years. Mean body mass index, z-body mass index, and oxygen saturation were 18.1 ± 3.6 kg·m-2, 0.58 ± 1.3, and 95.5 ± 2.4%, respectively. By multiple regression analysis, altitude proved to be the main predictor of oxygen saturation, with non-significant contributions of age, gender, and body mass index. According to quantile regression, the median estimate of oxygen saturation was 98.7 minus 1.7% per km of altitude above sea level, and the oxygen saturation fifth percentile 97.4 minus 2.7% per km of altitude. Altitude was the main determinant of oxygen saturation, which on average decreased 1.7% per km of elevation from a percentage of 98.7 at sea level. In contrast with adults, this study in children found no association between oxygen saturation and obesity or age.
Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments
NASA Astrophysics Data System (ADS)
Zvizdic, D.; Heinonen, M.; Sestan, D.
2015-08-01
The aim of this paper is to describe the evaluation process of the performance of the low-range saturator (LRS), when exposed to two different thermal environments. The examined saturator was designed, built, and tested at MIKES (Centre for Metrology and Accreditation, Finland), and then transported to the Laboratory for Process Measurement (LPM) in Croatia, where it was implemented in a new dew-point calibration system. The saturator works on a single-pressure-single-pass generation principle in the dew/frost-point temperature range between and . The purpose of the various tests performed at MIKES was to examine the efficiency and non-ideality of the saturator. As a test bath facility in Croatia differs from the one used in Finland, the same tests were repeated at LPM, and the effects of different thermal conditions on saturator performance were examined. Thermometers, pressure gauges, an air preparation system, and water for filling the saturator at LPM were also different than those used at MIKES. Results obtained by both laboratories indicate that the efficiency of the examined saturator was not affected either by the thermal conditions under which it was tested or by equipment used for the tests. Both laboratories concluded that LRS is efficient enough for a primary realization of the dew/frost-point temperature scale in the range from to , with flow rates between and . It is also shown that a considerable difference of the pre-saturator efficiency, indicated by two laboratories, did not have influence to the overall performance of the saturator. The results of the research are presented in graphical and tabular forms. This paper also gives a brief description of the design and operation principle of the investigated low-range saturator.
Self isolating high frequency saturable reactor
Moore, James A.
1998-06-23
The present invention discloses a saturable reactor and a method for decoupling the interwinding capacitance from the frequency limitations of the reactor so that the equivalent electrical circuit of the saturable reactor comprises a variable inductor. The saturable reactor comprises a plurality of physically symmetrical magnetic cores with closed loop magnetic paths and a novel method of wiring a control winding and a RF winding. The present invention additionally discloses a matching network and method for matching the impedances of a RF generator to a load. The matching network comprises a matching transformer and a saturable reactor.
Acoustoelectric current saturation in c-axis fiber-textured polycrystalline zinc oxide films
NASA Astrophysics Data System (ADS)
Pompe, T.; Srikant, V.; Clarke, D. R.
1996-12-01
Acoustoelectric current saturation, which until now has only been observed in piezoelectric single crystals, is observed in thin polycrystalline zinc oxide films. Epitaxial ZnO films on c-plane sapphire and textured ZnO polycrystalline films on fused silica both exhibit current saturation phenomenon. The values of the saturation current densities are in the range 105-106 A/cm2, depending on the carrier concentration in the film, with corresponding saturation electric fields of 3-5×103 V/cm. In addition to the current saturation, the electrical properties of the films degraded with the onset of the acoustoelectric effect but could be restored by annealing at 250 °C in a vacuum for 30 min.
Saturation-dependent solute dispersivity in porous media: Pore-scale processes
NASA Astrophysics Data System (ADS)
Raoof, A.; Hassanizadeh, S. M.
2013-04-01
It is known that in variably saturated porous media, dispersion coefficient depends on Darcy velocity and water saturation. In one-dimensional flow, it is commonly assumed that the dispersion coefficient is a linear function of velocity. The coefficient of proportionality, called the dispersivity, is considered to depend on saturation. However, there is not much known about its dependence on saturation. In this study, we investigate, using a pore network model, how the longitudinal dispersivity varies nonlinearly with saturation. We schematize the porous medium as a network of pore bodies and pore throats with finite volumes. The pore space is modeled using the multidirectional pore-network concept, which allows for a distribution of pore coordination numbers. This topological property together with the distribution of pore sizes are used to mimic the microstructure of real porous media. The dispersivity is calculated by solving the mass balance equations for solute concentration in all network elements and averaging the concentrations over a large number of pores. We have introduced a new formulation of solute transport within pore space, where we account for different compartments of residual water within drained pores. This formulation makes it possible to capture the effect of limited mixing due to partial filling of the pores under variably saturated conditions. We found that dispersivity increases with the decrease in saturation, it reaches a maximum value, and then decreases with further decrease in saturation. To show the capability of our formulation to properly capture the effect of saturation on solute dispersion, we applied it to model the results of a reported experimental study.
NASA Astrophysics Data System (ADS)
Diao, Yu; Liu, Lei; Xia, Sihao; Kong, Yike
2017-05-01
To investigate the influences of dangling bonds on GaN nanowires surface, the differences in optoelectronic properties between H-saturated and unsaturated GaN nanowires are researched through first-principles study. The GaN nanowires along the [0001] growth direction with diameters of 3.7, 7.5 and 9.5 Å are considered. According to the results, H-saturated GaN nanowires are more stable than the unsaturated ones. With increasing nanowire diameter, unsaturated GaN nanowires become more stable, while the stability of H-saturated GaN nanowires has little change. After geometry optimization, the atomic displacements of unsaturated and H-saturated models are almost reversed. In (0001) crystal plane, Ga atoms tend to move inwards and N atoms tend to move outwards slightly for the unsaturated nanowires, while Ga atoms tend to move outwards and N atoms tend to move inwards slightly for the H-saturated nanowires. Besides, with increasing nanowire diameter, the conduction band minimum of H-saturated nanowire moves to the lower energy side, while that of the unsaturated nanowire changes slightly. The bandgaps of H-saturated nanowires are approaching to bulk GaN as the diameter increases. Absorption curves and reflectivity curves of the unsaturated and H-saturated nanowires exhibit the same trend with the change of energy except the H-saturated models which show larger variations. Through all the calculated results above, we can better understand the effects of dangling bonds on the optoelectronic properties of GaN nanowires and select more proper calculation models and methods for other calculations.
NASA Astrophysics Data System (ADS)
Liu, Yu; Xue, Ziqiu; Park, Hyuck; Kiyama, Tamotsu; Zhang, Yi; Nishizawa, Osamu; Chae, Kwang-seok
2015-12-01
Complex electrical impedance measurements were performed on a brine-saturated Berea sandstone core while oil and CO2 were injected at different pressures and temperatures. The saturations of brine, oil, and CO2 in the core were simultaneously estimated using an X-ray computed tomography scanner. The formation factor of this Berea core and the resistivity indexes versus the brine saturations were calculated using Archie's law. The experimental results found different flow patterns of oil under different pressures and temperatures. Fingers were observed for the first experiment at 10 MPa and 40 °C. The fingers were restrained as the viscosity ratio of oil and water changed in the second (10 MPa and 25 °C) and third (5 MPa and 25 °C) experiments. The resistivity index showed an exponential increase with a decrease in brine saturation. The saturation exponent varied from 1.4 to 4.0 at different pressure and temperature conditions. During the oil injection procedure, the electrical impedance increased with oil saturation and was significantly affected by different oil distributions; therefore, the impedance varied whether the finger was remarkable or not, even if the oil saturation remained constant. During the CO2 injection steps, the impedance showed almost no change with CO2 saturation because the brine in the pores became immobile after the oil injection.
Assessment of oxygen saturation in dental pulp of permanent teeth with periodontal disease.
Giovanella, Larissa Bergesch; Barletta, Fernando Branco; Felippe, Wilson Tadeu; Bruno, Kely Firmino; de Alencar, Ana Helena Gonçalves; Estrela, Carlos
2014-12-01
In individuals with periodontal disease, dental pulp status should be determined before a treatment plan is made. Pulse oximeters are promising diagnostic tools to evaluate pulp vascularization. This study used pulse oximetry to determine the level of oxygen saturation in dental pulp of intact permanent teeth with periodontal attachment loss (PAL) and gingival recession (GR) and to evaluate the correlation between periodontal disease and level of oxygen saturation in the pulp. This study included 67 anterior teeth of 35 patients; all teeth showed intact crowns, PAL, a periodontal pocket (PP), and GR. The teeth underwent periodontal examination, cold and electric pulp testing, and pulse oximetry measurements. The Pearson correlation coefficient and a linear regression coefficient were calculated to evaluate the degree of correlation between periodontal disease markers (PAL, PP, and GR) and the level of oxygen saturation in dental pulp. These tests also evaluated possible associations between oxygen saturation and cold and electric pulp testing. PAL, PP, and GR had negative correlations with oxygen saturation in dental pulp. Conversely, no statistically significant association was found between oxygen saturation in dental pulp and the response to electric sensibility testing. Oxygen saturation was lower in the pulp of permanent teeth with PAL, PP, and GR, indicating that periodontal disease correlates with the level of oxygen saturation in the pulp. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hader, J.; Moloney, J. V.; College of Optical Sciences, University of Arizona, Tucson, Arizona 85721
2016-02-07
Fully microscopic many-body calculations are used to study the influence of strong sub-picosecond pulses on the carrier distributions and corresponding optical response in saturable absorbers used for mode-locking—semiconductor (quantum well) saturable absorber mirrors (SESAMs) and single layer graphene based saturable absorber mirrors (GSAMs). Unlike in GSAMs, the saturation fluence and recovery time in SESAMs show a strong spectral dependence. While the saturation fluence in the SESAM is minimal at the excitonic bandgap, the optimal recovery time and least pulse distortion due to group delay dispersion are found for excitation higher in the first subband. For excitation near the SESAM bandgap,more » the saturation fluence is about one tenth of that in the GSAM. At energies above the bandgap, the fluences in both systems become similar. A strong dependence of the saturation fluence on the pulse width in both systems is caused by carrier relaxation during the pulse. The recovery time in graphene is found to be about two to four times faster than that in the SESAMs. The occurrence of negative differential transmission in graphene is shown to be caused by dopant related carriers. In SESAMs, a negative differential transmission is found when exciting below the excitonic resonance where excitation induced dephasing leads to an enhancement of the absorption. Comparisons of the simulation data to the experiment show a very good quantitative agreement.« less
Saturated fat, carbohydrate, and cardiovascular disease.
Siri-Tarino, Patty W; Sun, Qi; Hu, Frank B; Krauss, Ronald M
2010-03-01
A focus of dietary recommendations for cardiovascular disease (CVD) prevention and treatment has been a reduction in saturated fat intake, primarily as a means of lowering LDL-cholesterol concentrations. However, the evidence that supports a reduction in saturated fat intake must be evaluated in the context of replacement by other macronutrients. Clinical trials that replaced saturated fat with polyunsaturated fat have generally shown a reduction in CVD events, although several studies showed no effects. An independent association of saturated fat intake with CVD risk has not been consistently shown in prospective epidemiologic studies, although some have provided evidence of an increased risk in young individuals and in women. Replacement of saturated fat by polyunsaturated or monounsaturated fat lowers both LDL and HDL cholesterol. However, replacement with a higher carbohydrate intake, particularly refined carbohydrate, can exacerbate the atherogenic dyslipidemia associated with insulin resistance and obesity that includes increased triglycerides, small LDL particles, and reduced HDL cholesterol. In summary, although substitution of dietary polyunsaturated fat for saturated fat has been shown to lower CVD risk, there are few epidemiologic or clinical trial data to support a benefit of replacing saturated fat with carbohydrate. Furthermore, particularly given the differential effects of dietary saturated fats and carbohydrates on concentrations of larger and smaller LDL particles, respectively, dietary efforts to improve the increasing burden of CVD risk associated with atherogenic dyslipidemia should primarily emphasize the limitation of refined carbohydrate intakes and a reduction in excess adiposity.
Whyte, Robin K; Nelson, Harvey; Roberts, Robin S; Schmidt, Barbara
2017-03-01
It has been reported in the 3 Benefits of Oxygen Saturation Targeting (BOOST-II) trials that changes in oximeter calibration software resulted in clearer separation between the oxygen saturations in the two trial target groups. A revised analysis of the published BOOST-II data does not support this conclusion. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Dongqing; Wei, Jianxin; Di, Bangrang; Ding, Pinbo; Huang, Shiqi; Shuai, Da
2018-03-01
Understanding the influence of lithology, porosity, permeability, pore structure, fluid content and fluid distribution on the elastic wave properties of porous rocks is of great significance for seismic exploration. However, unlike conventional sandstones, the petrophysical characteristics of tight sandstones are more complex and less understood. To address this problem, we measured ultrasonic velocity in partially saturated tight sandstones under different effective pressures. A new model is proposed, combining the Mavko-Jizba-Gurevich relations and the White model. The proposed model can satisfactorily simulate and explain the saturation dependence and pressure dependence of velocity in tight sandstones. Under low effective pressure, the relationship of P-wave velocity to saturation is pre-dominantly attributed to local (pore scale) fluid flow and inhomogeneous pore-fluid distribution (large scale). At higher effective pressure, local fluid flow gradually decreases, and P-wave velocity gradually shifts from uniform saturation towards patchy saturation. We also find that shear modulus is more sensitive to saturation at low effective pressures. The new model includes wetting ratio, an adjustable parameter that is closely related to the relationship between shear modulus and saturation.
Which blood oxygen can sensitively indicate shock severity?
NASA Astrophysics Data System (ADS)
Pan, Boan; Li, Kai; Gao, Yuan; Ruan, Zhengshang; Li, Ting
2016-03-01
Clinical shock-monitoring mainly depends on measuring oxygen saturations from SVC blood samples invasively. The golden standard indicator is the central internal jugular vein oxygenation (SjvO2). Using near-infrared spectroscopy (NIRS) also can monitor shock in some papers published, but there is no discussion about which oxygen saturation (cerebral venous oxygen saturation, ScvO2; tissue oxygen saturation of internal jugular area; tissue oxygen saturation of extremities areas) can monitor shock patient more sensitively and accurately. The purpose of this paper is to examine which one is most effective. In order to discuss the problem, we continuously detected 56 critical patients who may be into shock state using NIRS oximeter at prefrontal, internal jugular vein area and forearm, and chose 24 patients who were into shock and then out of shock from the 56 critical patients. Combined with the patients' condition, the pulse oxygen saturation is most sensitively to monitoring shock than the others, and the internal jugular vein area oxygen saturation is most effective.
Biodegradation of crude oil saturated fraction supported on clays.
Ugochukwu, Uzochukwu C; Jones, Martin D; Head, Ian M; Manning, David A C; Fialips, Claire I
2014-02-01
The role of clay minerals in crude oil saturated hydrocarbon removal during biodegradation was investigated in aqueous clay/saturated hydrocarbon microcosm experiments with a hydrocarbon degrading microorganism community. The clay minerals used for this study were montmorillonite, palygorskite, saponite and kaolinite. The clay mineral samples were treated with hydrochloric acid and didecyldimethylammonium bromide to produce acid activated- and organoclays respectively which were used in this study. The production of organoclay was restricted to only montmorillonite and saponite because of their relative high CEC. The study indicated that acid activated clays, organoclays and unmodified kaolinite, were inhibitory to biodegradation of the hydrocarbon saturates. Unmodified saponite was neutral to biodegradation of the hydrocarbon saturates. However, unmodified palygorskite and montmorillonite were stimulatory to biodegradation of the hydrocarbon saturated fraction and appears to do so as a result of the clays' ability to provide high surface area for the accumulation of microbes and nutrients such that the nutrients were within the 'vicinity' of the microbes. Adsorption of the saturated hydrocarbons was not significant during biodegradation.
Determining water saturation in diatomite using wireline logs, Lost Hills field, California
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilodeau, B.J.
1995-12-31
There is a long-held paradigm in the California oil industry that wireline log evaluation does not work in Monterey Formation lithologies. This study demonstrates that it is possible to calculate accurate oil saturation from wireline log data in the diatomite reservoir at Lost Hills field, California. The ability to calculate simple but accurate oil saturation is important because it allows field management teams to map pay, plan development and waterflood programs, and make estimates of reserves more accurate than those based on core information alone. Core data from eight wells were correlated with modern resistivity and porosity logs, incorporating moremore » than 2000 ft of reservoir section. Porosity was determined from bulk density and water saturation was determined using the Archie equation. Crossplots of corrected core oil saturation versus Archie oil saturation (1-S{sub w}) confirm the accuracy of the algorithm. Improvements in the accuracy and precision of the calculated oil saturation will require more detailed reservoir characterization to take into account lithologic variation.« less
Jaffery, Zehra; Ananthasubramaniam, Karthik
2008-03-01
Benzocaine induced methemoglobinemia is an uncommon, potentially fatal condition. A 44-year-old woman with a history of hepatitis C and intravenous drug use was referred for transesophageal echocardiography for bacteremia evaluation. During induction of topical anesthesia with benzocaine spray she became cyanotic. Pulse oximetry revealed marked desaturation (75%) but was discordant from arterial blood O(2) saturation (99%). Due to clinical suspicion, methemoglobin level was measured and noted to be 69%. The patient was treated with 2 mg/kg of methylene blue intravenously with resolution of her symptoms. Physicians using topical anesthesia in endoscopic suites should be aware of this rare, potentially life-threatening treatable condition. High clinical suspicion and availability of methylene blue in endoscopy suites will facilitate prompt diagnosis and treatment.
An ISEE/Whistler model of equatorial electron density in the magnetosphere
NASA Technical Reports Server (NTRS)
Carpenter, D. L.; Anderson, R. R.
1992-01-01
Attention is given to an empirical model of equatorial electron density in the magnetosphere covering the L range 2.25-8. Although the model is primarily intended for application to the local time interval 00-15 MLT, a way to extend the model to the 15-24-MLT period is presented. The model describes, in piecewise fashion, the 'saturated' plasmasphere, the region of steep plasmapause gradients, and the plasma trough. Within the plasmasphere the model profile can be expressed as logne - Sigma-xi, where x1 = -0.3145L + 3.9043 is the principal or 'reference' term, and additional terms account for: a solar cycle variation with a peak at solar maximum; an annual variation with a December maximum; and a semiannual variation with equinoctial maxima.
Kim, Jongpal; Kim, Jihoon; Ko, Hyoungho
2015-12-31
To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG) readout chip is fabricated using a 0.13-μm complementary metal-oxide-semiconductor (CMOS) process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms.
Kim, Jongpal; Kim, Jihoon; Ko, Hyoungho
2015-01-01
To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG) readout chip is fabricated using a 0.13-μm complementary metal–oxide–semiconductor (CMOS) process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms. PMID:26729122
Absolute charge calibration of scintillating screens for relativistic electron detection
NASA Astrophysics Data System (ADS)
Buck, A.; Zeil, K.; Popp, A.; Schmid, K.; Jochmann, A.; Kraft, S. D.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Karsch, S.; Pawelke, J.; Sauerbrey, R.; Cowan, T.; Krausz, F.; Schramm, U.
2010-03-01
We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm2. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm2 was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.
NASA Technical Reports Server (NTRS)
Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)
1999-01-01
A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.
Wind tunnel simulation of air pollution dispersion in a street canyon.
Civis, Svatopluk; Strizík, Michal; Janour, Zbynek; Holpuch, Jan; Zelinger, Zdenek
2002-01-01
Physical simulation was used to study pollution dispersion in a street canyon. The street canyon model was designed to study the effect of measuring flow and concentration fields. A method of C02-laser photoacoustic spectrometry was applied for detection of trace concentration of gas pollution. The advantage of this method is its high sensitivity and broad dynamic range, permitting monitoring of concentrations from trace to saturation values. Application of this method enabled us to propose a simple model based on line permeation pollutant source, developed on the principle of concentration standards, to ensure high precision and homogeneity of the concentration flow. Spatial measurement of the concentration distribution inside the street canyon was performed on the model with reference velocity of 1.5 m/s.
Saturable inductor and transformer structures for magnetic pulse compression
Birx, Daniel L.; Reginato, Louis L.
1990-01-01
Saturable inductor and transformer for magnetic compression of an electronic pulse, using a continuous electrical conductor looped several times around a tightly packed core of saturable inductor material.
Pixel-based absorption correction for dual-tracer fluorescence imaging of receptor binding potential
Kanick, Stephen C.; Tichauer, Kenneth M.; Gunn, Jason; Samkoe, Kimberley S.; Pogue, Brian W.
2014-01-01
Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order to correct for these tissue optical differences in signal detection. Changes in blood volume [1-3%] and hemoglobin oxygen saturation [0-100%] were demonstrated to introduce substantial distortions to receptor binding estimates (error > 30%), whereas sampled depth was relatively insensitive to wavelength (error < 6%). In response, a pixel-by-pixel normalization of tracer inputs immediately post-injection was found to account for spatial heterogeneities in local absorption properties. Application of the pixel-based normalization method to an in vivo imaging study demonstrated significant improvement, as compared with a reference tissue normalization approach. PMID:25360349
Albergamo, Ambrogina; Rigano, Francesca; Purcaro, Giorgia; Mauceri, Angela; Fasulo, Salvatore; Mondello, Luigi
2016-11-15
The present work aims to elucidate the free fatty acid (FFA) profile of the mussel Mytilus galloprovincialis caged in an anthropogenically impacted area and in a reference site through an innovative and validated analytical approach for the assessment of biological alterations induced by marine pollution. The FFA pattern is involved in the regulation of different cellular pathways and differs with respect to metabolic stimuli. To this purpose, the lipid fraction of mussels coming from both sampling areas was extracted and the FFA fractions were isolated and purified by a solid phase extraction; then, nano-scale liquid chromatography coupled to electron ionization mass spectrometry (nanoLC-EI-MS) was employed for the characterization of the two samples. A total of 19 and 17 FFAs were reliably identified in the mussels coming from the reference and polluted site, respectively. Significant qualitative and quantitative differences found in saturated, monounsaturated and polyunsaturated species may be exploited as typical pollution biomarkers (e.g. alteration of the fatty acid biosynthetic system and lipotoxicity) and explain adverse and compromising effects (e.g. oxidative stress and inflammatory processes) related to environmental pollution. Copyright © 2016 Elsevier B.V. All rights reserved.
Pressure drop for inertial flows in elastic porous media
NASA Astrophysics Data System (ADS)
Pauthenet, Martin; Bottaro, Alessandro; Davit, Yohan; Quintard, Michel; porous media Team
2017-11-01
The effect of the porosity and of the elastic properties of anisotropic solid skeletons saturated by a fluid is studied for flows displaying unsteady inertial effects. Insight is achieved by direct numerical simulations of the Navier-Stokes equations for model porous media, with inclusions which can oscillate with respect to their reference positions because of the presence of a restoring elastic force modeled by a spring. The numerical technique is based on the immersed boundary method, to easily allow for the displacement of pores of arbitrary shapes and dimensions. Solid contacts are anelastic. The parameters examined include the local Reynolds number, Red , based on the mean velocity through the reference unit cell and the characteristic size of the inclusions, the direction of the macroscopic forcing pressure gradient, the reduced frequency, f*, ratio of the flow frequency to the natural frequency of the spring-mass system, and the reduced mass, m*, ratio of the solid to the fluid density. Results demonstrate the effect of these parameters, and permit to determine the filtration laws useful for the subsequent macroscopic modeling of these flows through the volume averaged Navier-Stokes equations. IDEX Foundation of the University of Toulouse and HPC resources of the CALMIP supercomputing center.
The determination of water in crude oil and transformer oil reference materials.
Margolis, Sam A; Hagwood, Charles
2003-05-01
The measurement of the amount of water in oils is of significant economic importance to the industrial community, particularly to the electric power and crude oil industries. The amount of water in transformer oils is critical to their normal function and the amount of water in crude oils affects the cost of the crude oil at the well head, the pipeline, and the refinery. Water in oil Certified Reference Materials (CRM) are essential for the accurate calibration of instruments that are used by these industries. Three NIST Standard Reference Materials (SRMs) have been prepared for this purpose. The water in these oils has been measured by both coulometric and volumetric Karl Fischer methods. The compounds (such as sulfur compounds) that interfere with the Karl Fischer reaction (interfering substances) and inflate the values for water by also reacting with iodine have been measured coulometrically. The measured water content of Reference Material (RM) 8506a Transformer Oil is 12.1+/-1.9 mg kg(-1) (plus an additional 6.2+/-0.9 mg kg(-1) of interfering substances). The measured water content of SRM 2722 Sweet Crude Oil, is 99+/-6 mg kg(-1) (plus an additional 5+/-2 mg kg(-1) of interfering substances). The measured water content of SRM 2721 Sour Crude Oil, is 134+/-18 mg kg(-1) plus an additional 807+/-43 mg kg(-1) of interfering substances. Interlaboratory studies conducted with these oil samples (using SRM 2890, water saturated 1-octanol, as a calibrant) are reported. Some of the possible sources of bias in these measurements were identified, These include: improperly calibrated instruments, inability to measure the calibrant accurately, Karl Fischer reagent selection, and volatilization of the interfering substances in SRM 2721.
NASA Technical Reports Server (NTRS)
Righter, Kevin
2009-01-01
Highly siderophile elements (HSE; Re, Au and the platinum group elements) in shergottites exhibit a wide range from very high, similar to the terrestrial mantle, to very low, similar to sulfide saturated mid ocean ridge basalt (e.g., [1]). This large range has been difficult to explain without good constraints on sulfide saturation or under-saturation [2]. A new model for prediction of sulfide saturation places new constraints on this problem [3]. Shergottite data: For primitive shergottites, pressure and temperature estimates are between 1.2-1.5 GPa, and 1350-1470 C [4]. The range of oxygen fugacities is from FMQ-2 to IW, where the amount of Fe2O3 is low and thus does not have a significant effect on the S saturation values. Finally, the bulk compositions of shergottites have been reported in many recent studies (e.g., [5]). All of this information will be used to test whether shergottites are sulfide saturated [3]. Modeling values and results: The database for HSE partition coefficients has been growing with many new data for silicates and oxides [6-8] to complement a large sulfide database [9- 11]. Combining these data with simple batch melting models allows HSE contents of mantle melts to be estimated for sulfide-bearing vs. sulfide-free mantle. Combining such models with fractional crystallization modeling (e.g., [12]) allows HSE contents of more evolved liquids to be modeled. Most primitive shergottites have high HSE contents (and low S contents) that can be explained by sulfide under-saturated melting of the mantle. An exception is Dhofar 019 which has high S contents and very low HSE contents suggesting sulfide saturation. Most evolved basaltic shergottites have lower S contents than saturation, and intermediate HSE contents that can be explained by olivine, pyroxene, and chromite fractionation. An exception is EET A79001 lithology B, which has very low HSE contents and S contents higher than sulfide saturation values . evidence for sulfide saturation during late fractional crystallization. These results show that shergottite HSE contents are controlled by silicates, oxides, and sulfides. In addition, the mantle producing the most primitive shergottites did not contain near chondritic relative ratios of the HSEs like the terrestrial mantle, and did not experience a late chondritic veneer.
A Modified Prophylactic Regimen for the Prevention of Otitis Externa in Saturation Divers
2013-10-01
Prophylactic Regimen for the Prevention of Otitis Externa in Saturation Divers Authors: DISTRIBUTION STATEMENT A. Paul C. Algra, LT, MC...May 2012 – May 2013 4. TITLE AND SUBTITLE A Modified Prophylactic Regimen for the Prevention of Otitis Externa in Saturation Divers...SUPPLEMENTARY NOTES 14. ABSTRACT To prevent acute otitis externa (AOE) in the saturation setting and to decrease the side effects
The effect of dilatancy on the unloading behavior of Mt. Helen tuff
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attia, A.V.; Rubin, M.B.
1993-11-01
In order to understand the role of rock dilatancy in modeling the response of partially saturated rock formations to underground nuclear explosions, we have developed a thermodynamically consistent model for a porous material, partially saturated with fluid. This model gives good predictions of the unloading behavior of dry, partially saturated, and fully saturated Mt. Helen tuff, as measured by Heard.
NASA Astrophysics Data System (ADS)
Xue, Chengqi; Li, Jing; Wang, Haiyan; Niu, Yafeng
2015-01-01
Color coding is often used to enhance decision quality in complex man-machine interfaces of integrated display systems. However, people are easily distracted by irrelevant colors and by the numerous data points and complex structures in the interface. Although an increasing number of studies are seriously focusing on the problem of achieving efficient color coding, few are able to determine the effects of target and distractor saturations on cognitive performance. To study the performances of target colors among distractors, a systematic experiment is conducted to assess the influence of high and low saturated targets on cognitive performance, and the affecting extent of different saturated distractors of homogeneous colors on targets. According to the analysis of the reaction time through the non-parametric statistical method, a calculation method of the cognitive performance of each color is proposed. Based on the calculation of the color differences and the accumulation of the reaction times, it is shown that with the different saturated distractors of homogeneous colors, the high saturated yellow targets perform better than the low saturated ones, and the green and blue targets have moderate performances. When searching for a singleton target placed on a black background, the color difference between the target and the distractor should be more than 20Δ E*ab units in the yellow saturation coding, whereas the color difference should be more than 40Δ E*ab units in the blue and green saturation coding. In addition, as regards saturation coding, the influence of the color difference between the target and the background on cognitive performance is greater than that of the color difference between the target and the distractor. Seemingly, the hue attribute determines whether the saturation difference between the target and the distractor affects the cognitive performance. Based on the experimental results, the simulation design of the instrument dials in a flight situation awareness interface is completed and tested. Simulation results show the feasibility of the method of choosing the target and distractor colors, and the proposed research provides the instruction for the color saturation design of the interface.
Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion
NASA Astrophysics Data System (ADS)
Kyriacou, P. A.; Shafqat, K.; Pal, S. K.
2007-10-01
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse oximeters showed gradual decrease of saturations during induced hypoperfusion which demonstrate the direct relation between blood volumes (PPG amplitudes), arterial vessel stenosis and blood oxygen saturation. The custom made pulse oximeter was found to be more sensitive to SpO2 changes than the commercial pulse oximeter especially at high occluding pressures.
Quantifying Hydrate Formation in Gas-rich Environments Using the Method of Characteristics
NASA Astrophysics Data System (ADS)
You, K.; Flemings, P. B.; DiCarlo, D. A.
2015-12-01
Methane hydrates hold a vast amount of methane globally, and have huge energy potential. Methane hydrates in gas-rich environments are the most promising production targets. We develop a one-dimensional analytical solution based on the method of characteristics to explore hydrate formation in such environments (Figure 1). Our solution shows that hydrate saturation is constant with time and space in a homogeneous system. Hydrate saturation is controlled by the initial thermodynamic condition of the system, and changed by the gas fractional flow. Hydrate saturation increases with the initial distance from the hydrate phase boundary. Different gas fractional flows behind the hydrate solidification front lead to different gas saturations at the hydrate solidification front. The higher the gas saturation at the front, the less the volume available to be filled by hydrate, and hence the lower the hydrate saturation. The gas fractional flow depends on the relative permeability curves, and the forces that drive the flow. Viscous forces (the drive for flow induced from liquid pressure gradient) dominate the flow, and hydrate saturation is independent on the gas supply rates and the flow directions at high gas supply rates. Hydrate saturation can be estimated as one minus the ratio of the initial to equilibrium salinity. Gravity forces (the drive for flow induced from the gravity) dominate the flow, and hydrate saturation depends on the flow rates and the flow directions at low gas supply rates. Hydrate saturation is highest for upward flow, and lowest for downward flow. Hydrate saturation decreases with the flow rate for upward flow, and increases with the flow rate for downward flow. This analytical solution illuminates how hydrate is formed by gas (methane, CO2, ethane, propane) flowing into brine-saturated sediments at both the laboratory and geological scales (Figure 1). It provides an approach to generalize the understanding of hydrate solidification in gas-rich environments, although complicated numerical models have been developed previously. Examples of gas expulsion into hydrate stability zones and the associated hydrate formation in both laboratory and geological scales, and CO2 sequestration into CO2-hydrates near the seafloor and under the permafrost will be presented.
NASA Astrophysics Data System (ADS)
LaForce, T.; Ennis-King, J.; Boreham, C.; Serno, S.; Cook, P. J.; Freifeld, B. M.; Gilfillan, S.; Jarrett, A.; Johnson, G.; Myers, M.; Paterson, L.
2015-12-01
Residual trapping efficiency is a critical parameter in the design of secure subsurface CO2 storage. Residual saturation is also a key parameter in oil and gas production when a field is under consideration for enhanced oil recovery. Tracers are an important tool that can be used to estimate saturation in field tests. A series of measurements of CO2 saturation in an aquifer were undertaken as part of the Otway stage 2B extension field project in Dec. 2014. These tests were a repeat of similar tests in the same well in 2011 with improvements to the data collection and handling method. Two single-well tracer tests using noble gas tracers were conducted. In the first test krypton and xenon are injected into the water-saturated formation to establish dispersivity of the tracers in single-phase flow. Near-residual CO2 saturation is then established near the well. In the second test krypton and xenon are injected with CO2-saturated water to measure the final CO2 saturation. The recovery rate of the tracers is similar to predicted rates using recently published partitioning coefficients. Due to technical difficulties, there was mobile CO2 in the reservoir throughout the second tracer test in 2014. As a consequence, it is necessary to use a variation of the previous simulation procedure to interpret the second tracer test. One-dimensional, radial simulations are used to estimate average saturation of CO2 near the well. Estimates of final average CO2 saturation are computed using two relative permeability models, thermal and isothermal simulations, and three sets of coefficients for the partitioning of the tracers between phases. Four of the partitioning coefficients used were not previously available in the literature. The noble gas tracer field test and analysis of the 2011 and 2014 data both give an average CO2 saturation that is consistent with other field measurements. This study has demonstrated the repeatability of the methodology for noble gas tracer tests in the field.
2012-01-01
Background Most modern citrus cultivars have an interspecific origin. As a foundational step towards deciphering the interspecific genome structures, a reference whole genome sequence was produced by the International Citrus Genome Consortium from a haploid derived from Clementine mandarin. The availability of a saturated genetic map of Clementine was identified as an essential prerequisite to assist the whole genome sequence assembly. Clementine is believed to be a ‘Mediterranean’ mandarin × sweet orange hybrid, and sweet orange likely arose from interspecific hybridizations between mandarin and pummelo gene pools. The primary goals of the present study were to establish a Clementine reference map using codominant markers, and to perform comparative mapping of pummelo, sweet orange, and Clementine. Results Five parental genetic maps were established from three segregating populations, which were genotyped with Single Nucleotide Polymorphism (SNP), Simple Sequence Repeats (SSR) and Insertion-Deletion (Indel) markers. An initial medium density reference map (961 markers for 1084.1 cM) of the Clementine was established by combining male and female Clementine segregation data. This Clementine map was compared with two pummelo maps and a sweet orange map. The linear order of markers was highly conserved in the different species. However, significant differences in map size were observed, which suggests a variation in the recombination rates. Skewed segregations were much higher in the male than female Clementine mapping data. The mapping data confirmed that Clementine arose from hybridization between ‘Mediterranean’ mandarin and sweet orange. The results identified nine recombination break points for the sweet orange gamete that contributed to the Clementine genome. Conclusions A reference genetic map of citrus, used to facilitate the chromosome assembly of the first citrus reference genome sequence, was established. The high conservation of marker order observed at the interspecific level should allow reasonable inferences of most citrus genome sequences by mapping next-generation sequencing (NGS) data in the reference genome sequence. The genome of the haploid Clementine used to establish the citrus reference genome sequence appears to have been inherited primarily from the ‘Mediterranean’ mandarin. The high frequency of skewed allelic segregations in the male Clementine data underline the probable extent of deviation from Mendelian segregation for characters controlled by heterozygous loci in male parents. PMID:23126659
Effects of saturation and contrast polarity on the figure-ground organization of color on gray.
Dresp-Langley, Birgitta; Reeves, Adam
2014-01-01
Poorly saturated colors are closer to a pure gray than strongly saturated ones and, therefore, appear less "colorful."Color saturation is effectively manipulated in the visual arts for balancing conflicting sensations and moods and for inducing the perception of relative distance in the pictorial plane. While perceptual science has proven quite clearly that the luminance contrast of any hue acts as a self-sufficient cue to relative depth in visual images, the role of color saturation in such figure-ground organization has remained unclear. We presented configurations of colored inducers on gray "test" backgrounds to human observers. Luminance and saturation of the inducers was uniform on each trial, but varied across trials. We ran two separate experimental tasks. In the relative background brightness task, perceptual judgments indicated whether the apparent brightness of the gray test background contrasted with, assimilated to, or appeared equal (no effect) to that of a comparison background with the same luminance contrast. Contrast polarity and its interaction with color saturation affected response proportions for contrast, assimilation and no effect. In the figure-ground task, perceptual judgments indicated whether the inducers appeared to lie in front of, behind, or in the same depth with the background. Strongly saturated inducers produced significantly larger proportions of foreground effects indicating that these inducers stand out as figure against the background. Weakly saturated inducers produced significantly larger proportions of background effects, indicating that these inducers are perceived as lying behind the backgrounds. We infer that color saturation modulates figure-ground organization, both directly by determining relative inducer depth, and indirectly, and in interaction with contrast polarity, by affecting apparent background brightness. The results point toward a hitherto undocumented functional role of color saturation in the genesis of form, and in particular figure-ground percepts in the absence of chromatostereopsis.
Yang, Xianjin; Chen, Xiao; Carrigan, Charles R.; ...
2014-06-03
A parametric bootstrap approach is presented for uncertainty quantification (UQ) of CO₂ saturation derived from electrical resistance tomography (ERT) data collected at the Cranfield, Mississippi (USA) carbon sequestration site. There are many sources of uncertainty in ERT-derived CO₂ saturation, but we focus on how the ERT observation errors propagate to the estimated CO₂ saturation in a nonlinear inversion process. Our UQ approach consists of three steps. We first estimated the observational errors from a large number of reciprocal ERT measurements. The second step was to invert the pre-injection baseline data and the resulting resistivity tomograph was used as the priormore » information for nonlinear inversion of time-lapse data. We assigned a 3% random noise to the baseline model. Finally, we used a parametric bootstrap method to obtain bootstrap CO₂ saturation samples by deterministically solving a nonlinear inverse problem many times with resampled data and resampled baseline models. Then the mean and standard deviation of CO₂ saturation were calculated from the bootstrap samples. We found that the maximum standard deviation of CO₂ saturation was around 6% with a corresponding maximum saturation of 30% for a data set collected 100 days after injection began. There was no apparent spatial correlation between the mean and standard deviation of CO₂ saturation but the standard deviation values increased with time as the saturation increased. The uncertainty in CO₂ saturation also depends on the ERT reciprocal error threshold used to identify and remove noisy data and inversion constraints such as temporal roughness. Five hundred realizations requiring 3.5 h on a single 12-core node were needed for the nonlinear Monte Carlo inversion to arrive at stationary variances while the Markov Chain Monte Carlo (MCMC) stochastic inverse approach may expend days for a global search. This indicates that UQ of 2D or 3D ERT inverse problems can be performed on a laptop or desktop PC.« less
Effects of saturation and contrast polarity on the figure-ground organization of color on gray
Dresp-Langley, Birgitta; Reeves, Adam
2014-01-01
Poorly saturated colors are closer to a pure gray than strongly saturated ones and, therefore, appear less “colorful.”Color saturation is effectively manipulated in the visual arts for balancing conflicting sensations and moods and for inducing the perception of relative distance in the pictorial plane. While perceptual science has proven quite clearly that the luminance contrast of any hue acts as a self-sufficient cue to relative depth in visual images, the role of color saturation in such figure-ground organization has remained unclear. We presented configurations of colored inducers on gray “test” backgrounds to human observers. Luminance and saturation of the inducers was uniform on each trial, but varied across trials. We ran two separate experimental tasks. In the relative background brightness task, perceptual judgments indicated whether the apparent brightness of the gray test background contrasted with, assimilated to, or appeared equal (no effect) to that of a comparison background with the same luminance contrast. Contrast polarity and its interaction with color saturation affected response proportions for contrast, assimilation and no effect. In the figure-ground task, perceptual judgments indicated whether the inducers appeared to lie in front of, behind, or in the same depth with the background. Strongly saturated inducers produced significantly larger proportions of foreground effects indicating that these inducers stand out as figure against the background. Weakly saturated inducers produced significantly larger proportions of background effects, indicating that these inducers are perceived as lying behind the backgrounds. We infer that color saturation modulates figure-ground organization, both directly by determining relative inducer depth, and indirectly, and in interaction with contrast polarity, by affecting apparent background brightness. The results point toward a hitherto undocumented functional role of color saturation in the genesis of form, and in particular figure-ground percepts in the absence of chromatostereopsis. PMID:25339931
NASA Astrophysics Data System (ADS)
Glaser, Barbara; Antonelli, Marta; Pfister, Laurent; Klaus, Julian
2017-04-01
Surface saturated areas are important for the on- and offset of hydrological connectivity within the hillslope-riparian-stream continuum. This is reflected in concepts such as variable contributing areas or critical source areas. However, we still lack a standardized method for areal mapping of surface saturation and for observing its spatiotemporal variability. Proof-of-concept studies in recent years have shown the potential of thermal infrared (TIR) imagery to record surface saturation dynamics at various temporal and spatial scales. Thermal infrared imagery is thus a promising alternative to conventional approaches, such as the squishy boot method or the mapping of vegetation. In this study we use TIR images to investigate the variability of surface saturated areas at different temporal and spatial scales in the forested Weierbach catchment (0.45 km2) in western Luxembourg. We took TIR images of the riparian zone with a hand-held FLIR infrared camera at fortnightly intervals over 18 months at nine different locations distributed over the catchment. Not all of the acquired images were suitable for a derivation of the surface saturated areas, as various factors influence the usability of the TIR images (e.g. temperature contrasts, shadows, fog). Nonetheless, we obtained a large number of usable images that provided a good insight into the dynamic behaviour of surface saturated areas at different scales. The images revealed how diverse the evolution of surface saturated areas can be throughout the hydrologic year. For some locations with similar morphology or topography we identified diverging saturation dynamics, while other locations with different morphology / topography showed more similar behaviour. Moreover, we were able to assess the variability of the dynamics of expansion / contraction of saturated areas within the single locations, which can help to better understand the mechanisms behind surface saturation development.
Lee, Myung Woong; Collett, Timothy S.
2013-01-01
Through the use of 2-D and 3-D seismic data, several gas hydrate prospects were identified in the Ulleung Basin, East Sea of Korea and thirteen drill sites were established and logging-while-drilling (LWD) data were acquired from each site in 2010. Sites UBGH2–6 and UBGH2–10 were selected to test a series of high amplitude seismic reflections, possibly from sand reservoirs. LWD logs from the UBGH2–6 well indicate that there are three significant sand reservoirs with varying thickness. Two upper sand reservoirs are water saturated and the lower thinly bedded sand reservoir contains gas hydrate with an average saturation of 13%, as estimated from the P-wave velocity. The well logs at the UBGH2–6 well clearly demonstrated the effect of scale-dependency on gas hydrate saturation estimates. Gas hydrate saturations estimated from the high resolution LWD acquired ring resistivity (vertical resolution of about 5–8 cm) reaches about 90% with an average saturation of 28%, whereas gas hydrate saturations estimated from the low resolution A40L resistivity (vertical resolution of about 120 cm) reaches about 25% with an average saturation of 11%. However, in the UBGH2–10 well, gas hydrate occupies a 5-m thick sand reservoir near 135 mbsf with a maximum saturation of about 60%. In the UBGH2–10 well, the average and a maximum saturation estimated from various well logging tools are comparable, because the bed thickness is larger than the vertical resolution of the various logging tools. High resolution wireline log data further document the role of scale-dependency on gas hydrate calculations.
Schramm, P; Tzanova, I; Hagen, F; Berres, M; Closhen, D; Pestel, G; Engelhard, K
2016-10-01
Neurosurgical operations in the dorsal cranium often require the patient to be positioned in a sitting position. This can be associated with decreased cardiac output and cerebral hypoperfusion, and possibly, inadequate cerebral oxygenation. In the present study, cerebral oxygen saturation was measured during neurosurgery in the sitting position and correlated with cardiac output. Perioperative cerebral oxygen saturation was measured continuously with two different monitors, INVOS ® and FORE-SIGHT ® . Cardiac output was measured at eight predefined time points using transoesophageal echocardiography. Forty patients were enrolled, but only 35 (20 female) were eventually operated on in the sitting position. At the first time point, the regional cerebral oxygen saturation measured with INVOS ® was 70 (sd 9)%; thereafter, it increased by 0.0187% min -1 (P<0.01). The cerebral tissue oxygen saturation measured with FORE-SIGHT ® started at 68 (sd 13)% and increased by 0.0142% min -1 (P<0.01). The mean arterial blood pressure did not change. Cardiac output was between 6.3 (sd 1.3) and 7.2 (1.8) litre min -1 at the predefined time points. Cardiac output, but not mean arterial blood pressure, showed a positive and significant correlation with cerebral oxygen saturation. During neurosurgery in the sitting position, the cerebral oxygen saturation slowly increases and, therefore, this position seems to be safe with regard to cerebral oxygen saturation. Cerebral oxygen saturation is stable because of constant CO and MAP, while the influence of CO on cerebral oxygen saturation seems to be more relevant. NCT01275898. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
HyspIRI High-Temperature Saturation Study
NASA Technical Reports Server (NTRS)
Realmuto, V.; Hook, S.; Foote, M.; Csiszar, I.; Dennison, P.; Giglio, L.; Ramsey, M.; Vaughan, R.G.; Wooster, M.; Wright, R.
2011-01-01
As part of the precursor activities for the HyspIRI mission, a small team was assembled to determine the optimum saturation level for the mid-infrared (4-?m) channel, which is dedicated to the measurement of hot targets. Examples of hot targets include wildland fires and active lava flows. This determination took into account both the temperature expected for the natural phenomena and the expected performance of the mid-infrared channel as well as its overlap with the other channels in the thermal infrared (7.5-12 ?m) designed to measure the temperature of lower temperature targets. Based on this work, the hot target saturation group recommends a saturation temperature of 1200 K for the mid-infrared channel. The saturation temperature of 1200 K represents a good compromise between the prevention of saturation and sensitivity to ambient temperature.
NASA Astrophysics Data System (ADS)
Liu, Kun; Sun, Jianmeng; Zhang, Hongpan; Liu, Haitao; Chen, Xiangyang
2018-02-01
Total water saturation is an important parameter for calculating the free gas content of shale gas reservoirs. Owing to the limitations of the Archie formula and its extended solutions in zones rich in organic or conductive minerals, a new method was proposed to estimate total water saturation according to the relationship between total water saturation, V P -to-V S ratio and total porosity. Firstly, the ranges of the relevant parameters in the viscoelastic BISQ model in shale gas reservoirs were estimated. Then, the effects of relevant parameters on the V P -to-V S ratio were simulated based on the partially saturated viscoelastic BISQ model. These parameters were total water saturation, total porosity, permeability, characteristic squirt-flow length, fluid viscosity and sonic frequency. The simulation results showed that the main factors influencing V P -to-V S ratio were total porosity and total water saturation. When the permeability and the characteristic squirt-flow length changed slightly for a particular shale gas reservoir, their influences could be neglected. Then an empirical equation for total water saturation with respect to total porosity and V P -to-V S ratio was obtained according to the experimental data. Finally, the new method was successfully applied to estimate total water saturation in a sequence formation of shale gas reservoirs. Practical applications have shown good agreement with the results calculated by the Archie model.
Lee, M.W.; Collett, T.S.
2011-01-01
In 2006, the U.S. Geological Survey (USGS) completed detailed analysis and interpretation of available 2-D and 3-D seismic data and proposed a viable method for identifying sub-permafrost gas hydrate prospects within the gas hydrate stability zone in the Milne Point area of northern Alaska. To validate the predictions of the USGS and to acquire critical reservoir data needed to develop a long-term production testing program, a well was drilled at the Mount Elbert prospect in February, 2007. Numerous well log data and cores were acquired to estimate in-situ gas hydrate saturations and reservoir properties.Gas hydrate saturations were estimated from various well logs such as nuclear magnetic resonance (NMR), P- and S-wave velocity, and electrical resistivity logs along with pore-water salinity. Gas hydrate saturations from the NMR log agree well with those estimated from P- and S-wave velocity data. Because of the low salinity of the connate water and the low formation temperature, the resistivity of connate water is comparable to that of shale. Therefore, the effect of clay should be accounted for to accurately estimate gas hydrate saturations from the resistivity data. Two highly gas hydrate-saturated intervals are identified - an upper ???43 ft zone with an average gas hydrate saturation of 54% and a lower ???53 ft zone with an average gas hydrate saturation of 50%; both zones reach a maximum of about 75% saturation. ?? 2009.
A 70 kV solid-state high voltage pulse generator based on saturable pulse transformer.
Fan, Xuliang; Liu, Jinliang
2014-02-01
High voltage pulse generators are widely applied in many fields. In recent years, solid-state and operating at repetitive mode are the most important developing trends of high voltage pulse generators. A solid-state high voltage pulse generator based on saturable pulse transformer is proposed in this paper. The proposed generator is consisted of three parts. They are charging system, triggering system, and the major loop. Saturable pulse transformer is the key component of the whole generator, which acts as a step-up transformer and main switch during working process of this generator. The circuit and working principles of the proposed pulse generator are introduced first in this paper, and the saturable pulse transformer used in this generator is introduced in detail. Circuit of the major loop is simulated to verify the design of the system. Demonstration experiments are carried out, and the results show that when the primary energy storage capacitor is charged to a high voltage, such as 2.5 kV, a voltage with amplitude of 86 kV can be achieved on the secondary winding. The magnetic core of saturable pulse transformer is saturated deeply and the saturable inductance of the secondary windings is very small. The switch function of the saturable pulse transformer can be realized ideally. Therefore, a 71 kV output voltage pulse is formed on the load. Moreover, the magnetic core of the saturable pulse transformer can be reset automatically.
Petr, Jan; Schramm, Georg; Hofheinz, Frank; Langner, Jens; van den Hoff, Jörg
2014-10-01
To estimate the relaxation time changes during Q2TIPS bolus saturation caused by magnetization transfer effects and to propose and evaluate an extended model for perfusion quantification which takes this into account. Three multi inversion-time pulsed arterial spin labeling sequences with different bolus saturation duration were acquired for five healthy volunteers. Magnetization transfer exchange rates in tissue and blood were obtained from control image saturation recovery. Cerebral blood flow (CBF) obtained using the extended model and the standard model was compared. A decrease of obtained CBF of 6% (10%) was observed in grey matter when the duration of bolus saturation increased from 600 to 900 ms (1200 ms). This decrease was reduced to 1.6% (2.8%) when the extended quantification model was used. Compared with the extended model, the standard model underestimated CBF in grey matter by 9.7, 15.0, and 18.7% for saturation durations 600, 900, and 1200 ms, respectively. Results for simulated single inversion-time data showed 5-16% CBF underestimation depending on blood arrival time and bolus saturation duration. Magnetization transfer effects caused by bolus saturation pulses should not be ignored when performing quantification as they can cause appreciable underestimation of the CBF. Copyright © 2013 Wiley Periodicals, Inc.
Chen, Pei; Cai, Xiaoxiao; Xu, Lijun; Zhang, Jing; Yang, Ying; Gao, Qianying; Ge, Jian; Yu, Keming; Zhuang, Jing
2017-09-01
To determine whether posterior chamber phakic implantable collamer lens (ICL) surgery in high myopia patients impedes oxygen saturation of retinal vessels. Mean oxygen saturation and diameter in retinal blood vessels were measured before and after ICL implantation surgery to correct high myopia refractive errors (i.e. -6.00 to -20.25 dioptres [D]), using an Oxymap T1 retinal oximeter. In 17 eyes of 17 patients, the Oxymap T1 retinal oximeter detected a small but significant decrease in oxygen saturation of retinal venules, 1-week postoperatively (compared to preoperative measurements). Moreover, at 1 week after ICL implantation, the diameter of patient retinal vessels had consistently contracted, compared to preoperative measurements. By 1 month after ICL surgery, however, both the oxygen saturation and retinal vessel diameter had returned to preoperative levels. Otherwise, no statistically significant difference in oxygen saturation and diameter of retinal arterioles was found when comparing their measurements before and 1 week after implantation. Stable levels of oxygen saturation in retinal vessels, as detected by the Oxymap T1 oximeter, show ICL implantation would not leave lasting impact or adverse effects to retina oxygen saturation in high myopia patients. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Yuniarti, Anni; Arifin, Mahfud; Sofyan, Emma Trinurasi; Natalie, Betty; Sudirja, Rija; Dahliani, Dewi
2018-02-01
Andisol, soil orders which covers an upland area dominantly. The aim of this research is to know the effect between the ameliorant of Sinabung volcanic ashes with the ameliorant of rock phosphatenanoparticle towards CEC and base saturation exchange (K, Na, Ca, Mg) and the base saturation on Ciater's Andisols, West Java. A randomized complete block design (RCBD) factorial with two factors was used in this research. The first factor is the volcanic ash and the second factor is rock phosphate which consists of four levels each amount of 0%, 2.5%, 5%, 7.5% with three replications. The result showed that there was no interaction between volcanic ash and rock phosphate nanoparticle formed in first month and fourth month towards the improvement of CEC and saturation base exchange rate unless magnesium cation exchange increased in fourth month. There was independent effect of volcanic ash formed nanoparticles towards base saturation exchange increased for 5% dose. There was independent effect of rock phosphate formed nanoparticles towards base saturation exchange and increased for 5% dose. The dose combination of volcanic ashes 7.5% with phosphate rock, 5% increased the base saturation in the first month incubation.
Saturated Fats and Cardiovascular Disease: Interpretations Not as Simple as They Once Were.
Bier, Dennis M
2016-09-09
Historically, the so-called "lipid hypothesis" has focused on the detrimental role of saturated fats per se in enhancing the risks of cardiovascular disease. Recently, a body of new information and systematic analyses of available data have questioned simple interpretation of the relationship of dietary saturated fats and of individual saturated fatty acids to CVD risk. Thus, current assessments of risks due to dietary fat consumption that emphasize the confounding nature of the dietary macronutrients substituted for dietary saturated fats and give broader recognition to the effect of patterns of food intake as a whole are the most productive approach to an overall healthy diet.
SAGUARO: a finite-element computer program for partially saturated porous flow problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eaton, R.R.; Gartling, D.K.; Larson, D.E.
1983-06-01
SAGUARO is a finite element computer program designed to calculate two-dimensional flow of mass and energy through porous media. The media may be saturated or partially saturated. SAGUARO solves the parabolic time-dependent mass transport equation which accounts for the presence of partially saturated zones through the use of highly non-linear material characteristic curves. The energy equation accounts for the possibility of partially saturated regions by adjusting the thermal capacitances and thermal conductivities according to the volume fraction of water present in the local pores. Program capabilities, user instructions and a sample problem are presented in this manual.
Beyond the Natural Proteome: Nondegenerate Saturation Mutagenesis-Methodologies and Advantages.
Ferreira Amaral, M M; Frigotto, L; Hine, A V
2017-01-01
Beyond the natural proteome, high-throughput mutagenesis offers the protein engineer an opportunity to "tweak" the wild-type activity of a protein to create a recombinant protein with required attributes. Of the various approaches available, saturation mutagenesis is one of the core techniques employed by protein engineers, and in recent times, nondegenerate saturation mutagenesis is emerging as the approach of choice. This review compares the current methodologies available for conducting nondegenerate saturation mutagenesis with traditional, degenerate saturation and briefly outlines the options available for screening the resulting libraries, to discover a novel protein with the required activity and/or specificity. © 2017 Elsevier Inc. All rights reserved.