Oishi, Sana; Kimura, Shin-Ichiro; Noguchi, Shuji; Kondo, Mio; Kondo, Yosuke; Shimokawa, Yoshiyuki; Iwao, Yasunori; Itai, Shigeru
2018-01-15
A new scale-down methodology from commercial rotary die scale to laboratory scale was developed to optimize a plant-derived soft gel capsule formulation and eventually manufacture superior soft gel capsules on a commercial scale, in order to reduce the time and cost for formulation development. Animal-derived and plant-derived soft gel film sheets were prepared using an applicator on a laboratory scale and their physicochemical properties, such as tensile strength, Young's modulus, and adhesive strength, were evaluated. The tensile strength of the animal-derived and plant-derived soft gel film sheets was 11.7 MPa and 4.41 MPa, respectively. The Young's modulus of the animal-derived and plant-derived soft gel film sheets was 169 MPa and 17.8 MPa, respectively, and both sheets showed a similar adhesion strength of approximately 4.5-10 MPa. Using a D-optimal mixture design, plant-derived soft gel film sheets were prepared and optimized by varying their composition, including variations in the mass of κ-carrageenan, ι-carrageenan, oxidized starch and heat-treated starch. The physicochemical properties of the sheets were evaluated to determine the optimal formulation. Finally, plant-derived soft gel capsules were manufactured using the rotary die method and the prepared soft gel capsules showed equivalent or superior physical properties compared with pre-existing soft gel capsules. Therefore, we successfully developed a new scale-down methodology to optimize the formulation of plant-derived soft gel capsules on a commercial scale. Copyright © 2017 Elsevier B.V. All rights reserved.
Wetted foam liquid fuel ICF target experiments
Olson, R. E.; Leeper, R. J.; Yi, S. A.; ...
2016-05-26
We are developing a new NIF experimental platform that employs wetted foam liquid fuel layer ICF capsules. We will use the liquid fuel layer capsules in a NIF sub-scale experimental campaign to explore the relationship between hot spot convergence ratio (CR) and the predictability of hot spot formation. DT liquid layer ICF capsules allow for flexibility in hot spot CR via the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density. Our hypothesis is that the predictive capability of hot spot formation is robust and 1D-like for a relatively low CR hot spot (CR~15), but will becomemore » less reliable as hot spot CR is increased to CR>20. Simulations indicate that backing off on hot spot CR is an excellent way to reduce capsule instability growth and to improve robustness to low-mode x-ray flux asymmetries. In the initial experiments, we will test our hypothesis by measuring hot spot size, neutron yield, ion temperature, and burn width to infer hot spot pressure and compare to predictions for implosions with hot spot CR's in the range of 12 to 25. Larger scale experiments are also being designed, and we will advance from sub-scale to full-scale NIF experiments to determine if 1D-like behavior at low CR is retained as the scale-size is increased. The long-term objective is to develop a liquid fuel layer ICF capsule platform with robust thermonuclear burn, modest CR, and significant α-heating with burn propagation.« less
1958-08-05
Photographed on: 08 05 1958. -- Impact test conducted by Langley's Hydrodynamics Division. The Division conducted a series of impact studies with full scale and model capsules of the original capsule shape A. Joseph Shortal wrote (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
1958-09-07
Photographed on: 08 05 1958. -- Impact test conducted by Langley's Hydrodynamics Division. The Division conducted a series of impact studies with full scale and model capsules of the original capsule shape A. Joseph Shortal wrote (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
Motion of an elastic capsule in a square microfluidic channel.
Kuriakose, S; Dimitrakopoulos, P
2011-07-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2) approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~a(3)/h ~ a(5). By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules.
Motion of an elastic capsule in a square microfluidic channel
Kuriakose, S.; Dimitrakopoulos, P.
2013-01-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2 approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~ a3/h ~ a5. By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules. PMID:21867212
Delamater, N D; Wilson, D C; Kyrala, G A; Seifter, A; Hoffman, N M; Dodd, E; Singleton, R; Glebov, V; Stoeckl, C; Li, C K; Petrasso, R; Frenje, J
2008-10-01
We present the calculations and preliminary results from experiments on the Omega laser facility using d-(3)He filled plastic capsule implosions in gold Hohlraums. These experiments aim to develop a technique to measure shell rho r and capsule unablated mass with proton spectroscopy and will be applied to future National Ignition Facility (NIF) experiments with ignition scale capsules. The Omega Hohlraums are 1900 microm length x 1200 microm diameter and have a 70% laser entrance hole. This is approximately a 0.2 NIF scale ignition Hohlraum and reaches temperatures of 265-275 eV similar to those during the peak of the NIF drive. These capsules can be used as a diagnostic of shell rho r, since the d-(3)He gas fill produces 14.7 MeV protons in the implosion, which escape through the shell and produce a proton spectrum that depends on the integrated rho r of the remaining shell mass. The neutron yield, proton yield, and spectra change with capsule shell thickness as the unablated mass or remaining capsule rho r changes. Proton stopping models are used to infer shell unablated mass and shell rho r from the proton spectra measured with different filter thicknesses. The experiment is well modeled with respect to Hohlraum energetics, neutron yields, and x-ray imploded core image size, but there are discrepancies between the observed and simulated proton spectra.
NASA Astrophysics Data System (ADS)
Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.
2016-03-01
While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.
The Bigfoot Drive; Experimental Results
NASA Astrophysics Data System (ADS)
Baker, Kevin; Thomas, Cliff; Khan, Shahab; Casey, Daniel; Spears, Brian; Nora, Ryan; Munro, Davis; Eder, David; Milovich, Jose; Berger, Dick; Strozzi, David; Goyon, Clement; Turnbull, David; Ma, Tammy; Izumi, Nobuhiko; Benedetti, Robin; Millot, Marius; Celliers, Peter; Yeamans, Charles; Hatarik, Robert; Landen, Nino; Hurricane, Omar; Callahan, Debbie
2016-10-01
The Bigfoot platform was developed on the National Ignition Facility to investigate low convergence, high adiabat, high rhoR hotspot implosions. This platform was designed to be less susceptible to wall motion, LPI and CBET and to be more robust against capsule hydrodynamic instabilities. To date experimental studies have been carried out at two hohlraum scales, a 5.75 and 5.4 mm diameter hohlraum. We will present experimental results from these tuning campaigns including the shape vs. cone fraction, surrogacy comparisons of self-emission from the capsules vs. radiography of the imploding capsule and doped vs. undoped capsules. Prepared by LLNL under Contract DE-AC52-07NA27344.
Serajuddin, A T
1999-10-01
Although there was a great interest in solid dispersion systems during the past four decades to increase dissolution rate and bioavailability of poorly water-soluble drugs, their commercial use has been very limited, primarily because of manufacturing difficulties and stability problems. Solid dispersions of drugs were generally produced by melt or solvent evaporation methods. The materials, which were usually semisolid and waxy in nature, were hardened by cooling to very low temperatures. They were then pulverized, sieved, mixed with relatively large amounts of excipients, and encapsulated into hard gelatin capsules or compressed into tablets. These operations were difficult to scale up for the manufacture of dosage forms. The situation has, however, been changing in recent years because of the availability of surface-active and self-emulsifying carriers and the development of technologies to encapsulate solid dispersions directly into hard gelatin capsules as melts. Solid plugs are formed inside the capsules when the melts are cooled to room temperature. Because of surface activity of carriers used, complete dissolution of drug from such solid dispersions can be obtained without the need for pulverization, sieving, mixing with excipients, etc. Equipment is available for large-scale manufacturing of such capsules. Some practical limitations of dosage form development might be the inadequate solubility of drugs in carriers and the instability of drugs and carriers at elevated temperatures necessary to manufacture capsules.
Huang, Shih-Wei; Lin, Jia-Wei; Wang, Wei-Te; Wu, Chin-Wen; Liou, Tsan-Hon; Lin, Hui-Wen
2014-01-01
The purpose of this study was to investigate the prevalence and risk of adhesive capsulitis among hyperthyroidism patients. The data were obtained from the Longitudinal Health Insurance Database 2005 (LHID 2005) in Taiwan, using 1 million participants and a prospective population-based 7-year cohort study of survival analysis. The ambulatory-care claim records of patients diagnosed according to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes relating to hyperthyroidism between January 1, 2004 and December 31, 2007, were obtained. The prevalence and the adjusted hazard ratio (HR) of adhesive capsulitis among hyperthyroid patients and the control group were estimated. Of 4472 hyperthyroid patients, 162 (671/100 000 person-years) experienced adhesive capsulitis during the 24 122 person-year follow-up period. The crude HR of stroke was 1.26 (95% confidence interval [CI], 1.06 to 1.49), which was larger than that of the control group. The adjusted HR of developing adhesive capsulitis was 1.22 (95% CI, 1.03 to 1.45) for hyperthyroid patients during the 7-year follow-up period, which achieved statistical significance. The results of our large-scale longitudinal population-based study indicated that hyperthyroidism is an independent risk factor of developing adhesive capsulitis. PMID:24567049
Huang, Shih-Wei; Lin, Jia-Wei; Wang, Wei-Te; Wu, Chin-Wen; Liou, Tsan-Hon; Lin, Hui-Wen
2014-02-25
The purpose of this study was to investigate the prevalence and risk of adhesive capsulitis among hyperthyroidism patients. The data were obtained from the Longitudinal Health Insurance Database 2005 (LHID 2005) in Taiwan, using 1 million participants and a prospective population-based 7-year cohort study of survival analysis. The ambulatory-care claim records of patients diagnosed according to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes relating to hyperthyroidism between January 1, 2004 and December 31, 2007, were obtained. The prevalence and the adjusted hazard ratio (HR) of adhesive capsulitis among hyperthyroid patients and the control group were estimated. Of 4472 hyperthyroid patients, 162 (671/100,000 person-years) experienced adhesive capsulitis during the 24,122 person-year follow-up period. The crude HR of stroke was 1.26 (95% confidence interval [CI], 1.06 to 1.49), which was larger than that of the control group. The adjusted HR of developing adhesive capsulitis was 1.22 (95% CI, 1.03 to 1.45) for hyperthyroid patients during the 7-year follow-up period, which achieved statistical significance. The results of our large-scale longitudinal population-based study indicated that hyperthyroidism is an independent risk factor of developing adhesive capsulitis.
Surface Modification of ICF Target Capsules by Pulsed Laser Ablation
Carlson, Lane C.; Johnson, Michael A.; Bunn, Thomas L.
2016-06-30
Topographical modifications of spherical surfaces are imprinted on National Ignition Facility (NIF) target capsules by extending the capabilities of a recently developed full surface (4π) laser ablation and mapping apparatus. The laser ablation method combines the precision, energy density and long reach of a focused laser beam to pre-impose sinusoidal modulations on the outside surface of High Density Carbon (HDC) capsules and the inside surface of Glow Discharge Polymer (GDP) capsules. Sinusoidal modulations described in this paper have sub-micron to 10’s of microns vertical scale and wavelengths as small as 30 μm and as large as 200 μm. The modulatedmore » patterns are created by rastering a focused laser fired at discrete capsule surface locations for a specified number of pulses. The computer program developed to create these raster patterns uses inputs such as laser beam intensity profile, the material removal function, the starting surface figure and the desired surface figure. The patterns are optimized to minimize surface roughness. Lastly, in this paper, simulated surfaces are compared with actual ablated surfaces measured using confocal microscopy.« less
Capsule Escape Tests - Wallops Island
1959-05-14
Caption: Off the pad abort shot at Wallops using Langley PARD designed full scale capsule with Recruit rocket and extended skirt main parachute. Shows sequential images of launch and capsule splashdown.
The development of pyro shock test requirements for Viking Lander Capsule components
NASA Technical Reports Server (NTRS)
Barrett, S.
1975-01-01
The procedure used to derive component-level pyro shock specifications for the Viking Lander Capsule (VLC) is described. Effects of shock path distance and mechanical joints between the device and the point at which the environment is to be estimated are accounted for in the method. The validity of the prediction technique was verified by a series of shock tests on a full-scale structural model of the lander body.
Haines, Brian M.; Yi, S. A.; Olson, R. E.; ...
2017-07-10
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. In this paper, we present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surfacemore » roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Finally and nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).« less
NASA Astrophysics Data System (ADS)
Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.
2017-07-01
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).
1958-06-24
Testing of Mercury Capsule Shape A by the Hydrodynamics Division of Langley. Joseph Shortal wrote (vol. 3, p. 19): The Hydrodynamics Division provided assistance in determining landing loads. In this connection, after PARD engineers had unofficially approached that division to make some water impact tests with the boilerplate capsule, J.B. Parkinson, Hydrodynamics Chief visited Shortal to find out if the request had his support. Finding out that it did, Parkinson said, Its your capsule. If you want us to drop it in the water, we will do it. From Shortal (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
Ghosh, Pranay; Vahedipour, Kaveh; Lin, Min; Vogel, Jens H; Haynes, Charles A; von Lieres, Eric
2013-01-01
The zonal rate model (ZRM) has previously been applied for analyzing the performance of axial flow membrane chromatography capsules by independently determining the impacts of flow and binding related non-idealities on measured breakthrough curves. In the present study, the ZRM is extended to radial flow configurations, which are commonly used at larger scales. The axial flow XT5 capsule and the radial flow XT140 capsule from Pall are rigorously analyzed under binding and non-binding conditions with bovine serum albumin (BSA) as test molecule. The binding data of this molecule is much better reproduced by the spreading model, which hypothesizes different binding orientations, than by the well-known Langmuir model. Moreover, a revised cleaning protocol with NaCl instead of NaOH and minimizing the storage time has been identified as most critical for quantitatively reproducing the measured breakthrough curves. The internal geometry of both capsules is visualized by magnetic resonance imaging (MRI). The flow in the external hold-up volumes of the XT140 capsule was found to be more homogeneous as in the previously studied XT5 capsule. An attempt for model-based scale-up was apparently impeded by irregular pleat structures in the used XT140 capsule, which might lead to local variations in the linear velocity through the membrane stack. However, the presented approach is universal and can be applied to different capsules. The ZRM is shown to potentially help save valuable material and time, as the experiments required for model calibration are much cheaper than the predicted large-scale experiment at binding conditions. Biotechnol. Bioeng. 2013; 110: 1129–1141. © 2012 Wiley Periodicals, Inc. PMID:23097218
Yim, Sehyuk; Gultepe, Evin; Gracias, David H; Sitti, Metin
2014-02-01
This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy.
Water Landing Characteristics of a Reentry Capsule
NASA Technical Reports Server (NTRS)
1958-01-01
Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.
Water-Landing Characteristics of a Reentry Capsule
NASA Technical Reports Server (NTRS)
McGehee, John R.; Hathaway, Melvin E.; Vaughan, Victor L., Jr.
1959-01-01
Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.
Yilmaz, Mehmet Halit; Kantarci, Fatih; Adaletli, Ibrahim; Ulus, Sila; Gulsen, Fatih; Ozer, Harun; Aktas, Ilknur; Akgun, Kenan; Kanberoglu, Kaya
2007-04-01
Adhesive capsulitis of the shoulder is a condition of unknown aetiology that results in the development of restricted active and passive glenohumeral motion. It has been reported that magnetic resonance (MR) imaging is useful in diagnosing adhesive capsulitis. We carried out this study to assess how pain and/or resistance during contrast material injection affects the diagnosis of adhesive capsulitis on magnetic resonance (MR) arthrography. The study included MR arthrography examinations of 21 patients with a diagnosis of adhesive capsulitis. The control group consisted of 20 patients who presented clinically with rotator cuff tear. The pain (visual analog scale, VAS), resistance to injection and the amount of contrast material that could be injected during injection phase of MR arthrography was assessed and compared between groups. The patients in adhesive capsulitis group (mean VAS score 66.5+/-25.5) experienced more pain when compared with the control group (mean VAS score 34.9+/-27.7, P<0.001). A statistically significant difference (P<0.001) in terms of the amount of the injected fluid (4.3+/-2.6 ml for adhesive capsulitis group, and 10.9+/-4.1 ml for control group) was seen into the joint cavity. Resistance to injection was significantly more (P<0.001) in patients with adhesive capsulitis when compared to control group. Experience of pain during injection, a decreased amount of contrast material injected and resistance to injection in patients during injection phase of MR arthrography may suggest adhesive capsulitis.
Niederquell, Andreas; Kuentz, Martin
2011-03-01
These days an alternative to soft capsules is liquid-filled hard capsules. Their filling technology was investigated earlier with highly viscous formulations, while hardly any academic research focused on low-viscosity systems. Accordingly, this work addressed the filling of such oils that are splashing during the dosing process. It was aimed to first study capsule filling, using middle-chain triglycerides as reference oil, in order to then evaluate the concept of a new theoretical splashing degree for different oils. A laboratory-scale filling machine was used that included capsule sealing. Thus, the liquid encapsulation by microspray technology was employed to seal the dosage form. As a result of the study with reference oil, the filling volume and the temperature were found to be significant for the rate of leaking capsules. The filling volume was also important for weight variability of the capsules. However, most critical for this variability was the diameter of the filling nozzle. We proposed a power law for the coefficient of weight variability as a function of the nozzle diameter and the obtained exponent agreed with the proposed theory. Subsequently, a comparison of different oils revealed that the relative splashing degree shared a correlation with the coefficient of the capsule weight variability (Pearson product moment correlation of r=0.990). The novel theoretical concept was therefore found to be predictive for weight variability of the filled capsules. Finally, guidance was provided for the process development of liquid-filled capsules using low-viscosity oils. © 2011 American Association of Pharmaceutical Scientists
Mercury Capsule Separation Tests
1960-04-01
Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.
Yim, Sehyuk; Gultepe, Evin; Gracias, David H.
2014-01-01
This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy. PMID:24108454
"Killer" Microcapsules That Can Selectively Destroy Target Microparticles in Their Vicinity.
Arya, Chandamany; Oh, Hyuntaek; Raghavan, Srinivasa R
2016-11-02
We have developed microscale polymer capsules that are able to chemically degrade a certain type of polymeric microbead in their immediate vicinity. The inspiration here is from the body's immune system, where killer T cells selectively destroy cancerous cells or cells infected by pathogens while leaving healthy cells alone. The "killer" capsules are made from the cationic biopolymer chitosan by a combination of ionic cross-linking (using multivalent tripolyposphate anions) and subsequent covalent cross-linking (using glutaraldehyde). During capsule formation, the enzyme glucose oxidase (GOx) is encapsulated in these capsules. The target beads are made by ionic cross-linking of the biopolymer alginate using copper (Cu 2+ ) cations. The killer capsules harvest glucose from their surroundings, which is then enzymatically converted by GOx into gluconate ions. These ions are known for their ability to chelate Cu 2+ cations. Thus, when a killer capsule is next to a target alginate bead, the gluconate ions diffuse into the bead and extract the Cu 2+ cross-links, causing the disintegration of the target bead. Such destruction is visualized in real-time using optical microscopy. The destruction is specific, i.e., other microparticles that do not contain Cu 2+ are left undisturbed. Moreover, the destruction is localized, i.e., the targets destroyed in the short term are the ones right next to the killer beads. The time scale for destruction depends on the concentration of encapsulated enzyme in the capsules.
Development of orally disintegrating tablets comprising controlled-release multiparticulate beads
2012-01-01
Melperone is an atypical antipsychotic agent that has shown a wide spectrum of neuroleptic properties, particularly effective in the treatment of senile dementia and Parkinson’s-associated psychosis, and is marketed in Europe as an immediate-release (IR) tablet and syrup. An orally disintegrating tablet (ODT) dosage form would be advantageous for patients who experience difficulty in swallowing large tablets or capsules or those who experience dysphagia. Controlled-release (CR) capsule and ODT formulations containing melperone HCl were developed with target in vitro release profiles suitable for a once-daily dosing regimen. Both dosage forms allow for the convenient production of dose-proportional multiple strengths. Two ODT formulations exhibiting fast and medium release profiles and one medium release profile capsule formulation (each 50 mg) were tested in vivo using IR syrup as the reference. The two medium release formulations were shown to be bioequivalent to each other and are suitable for once-daily dosing. Based on the analytical and organoleptic test results, as well as the blend uniformity and in-process compression data at various compression forces using coated beads produced at one-tenth (1/10) commercial scale, both formulations in the form of CR capsules and CR ODTs have shown suitability for progression into further clinical development. PMID:22356215
Space capsule mounted in the Full Scale Wind Tunnel
1959-01-22
The Mercury space capsule undergoing tests in Full Scale Wind Tunnel, January 1959. Photograph published in Winds of Change, 75th Anniversary NASA publication, page 75, by James Schultz. Also Photograph published in Engineer in Charge: A History of the Langley Aeronautical Laboratory, 1917-1958, page 389, by James R. Hansen.
Capsule Performance Optimization in the National Ignition Campaign
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landen, O L; MacGowan, B J; Haan, S W
2009-10-13
A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting themore » key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.« less
Capsule performance optimization in the national ignition campaign
NASA Astrophysics Data System (ADS)
Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.
2010-08-01
A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.
Bennett, G. R.; Herrmann, M. C.; Edwards, M. J.; ...
2007-11-13
We present on the first inertial-confinement-fusion ignition facility, the target capsule will be DT filled through a long, narrow tube inserted into the shell. μg-scale shell perturbations Δm' arising from multiple, 10–50 μm-diameter, hollow SiO 2 tubes on x-ray-driven, ignition-scale, 1-mg capsules have been measured on a subignition device. Finally, simulations compare well with observation, whence it is corroborated that Δm' arises from early x-ray shadowing by the tube rather than tube mass coupling to the shell, and inferred that 10–20 μm tubes will negligibly affect fusion yield on a full-ignition facility.
Lorenz, Ralph D; Cabrol, Nathalie A
2018-05-01
A scale model of the proposed Titan Mare Explorer capsule was deployed at the Planetary Lake Lander field site at Laguna Negra, Chile. The tests served to calibrate models of wind-driven drift of the capsule and to understand its attitude motion in the wave field, as well as to identify dynamic and acoustic signatures of shoreline approach. This information enables formulation of onboard trigger criteria for near-shore science data acquisition. Key Words: Titan-Vehicle dynamics-Science autonomy-Lake. Astrobiology 18, 607-618.
Proposed pushered single shell capsule design for the investigation of mid/high Z mix on the NIF
NASA Astrophysics Data System (ADS)
Sacks, Ryan; Tipton, Robert; Graziani, Frank
2016-05-01
The CD Mix campaign has given a detailed explination of the mix mechanics in the current ignition capsule designs by investigating the relationship between material mixing, shell-fuel interfaces, and the change in thermonuclear yield given a deuterated layer in the capsule. Alternative ignition scenarios include the use of double shell designs that incorporate high-Z material in the capsule. Simulations are conducted on a proposed capsule platform using the ARES code on a scaled capsule design using a partially reduced glass capsule design. This allows for the inclusion of deuterium on the inner surface of the pusher layer similar to the CD mix experiments. The presence of silicon dioxide allows for the investigation of the influence of higher Z material on the mixing characteristics.
Gemini Capsule and Rendezvous Docking Simulator
1962-12-19
Practicing with a full-scale model of the Gemini Capsule in Langley's Rendezvous Docking Simulator. -- Caption and photograph published in Winds of Change, 75th Anniversary NASA publication, (page 89), by James Schultz.
Quantifying design trade-offs of beryllium targets on NIF
NASA Astrophysics Data System (ADS)
Yi, S. A.; Zylstra, A. B.; Kline, J. L.; Loomis, E. N.; Kyrala, G. A.; Shah, R. C.; Perry, T. S.; Kanzleiter, R. J.; Batha, S. H.; MacLaren, S. A.; Ralph, J. E.; Masse, L. P.; Salmonson, J. D.; Tipton, R. E.; Callahan, D. A.; Hurricane, O. A.
2017-10-01
An important determinant of target performance is implosion kinetic energy, which scales with the capsule size. The maximum achievable performance for a given laser is thus related to the largest capsule that can be imploded symmetrically, constrained by drive uniformity. A limiting factor for symmetric radiation drive is the ratio of hohlraum to capsule radii, or case-to-capsule ratio (CCR). For a fixed laser energy, a larger hohlraum allows for driving bigger capsules symmetrically at the cost of reduced peak radiation temperature (Tr). Beryllium ablators may thus allow for unique target design trade-offs due to their higher ablation efficiency at lower Tr. By utilizing larger hohlraum sizes than most modern NIF designs, beryllium capsules thus have the potential to operate in unique regions of the target design parameter space. We present design simulations of beryllium targets with a large CCR = 4.3 3.7 . These are scaled surrogates of large hohlraum low Tr beryllium targets, with the goal of quantifying symmetry tunability as a function of CCR. This work performed under the auspices of the U.S. DOE by LANL under contract DE-AC52- 06NA25396, and by LLNL under Contract DE-AC52-07NA27344.
Capsule Performance Optimization for the National Ignition Facility
NASA Astrophysics Data System (ADS)
Landen, Otto
2009-11-01
The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, D. S.; Weber, C. R.; Milovich, J. L.
In order to achieve the several hundred Gbar stagnation pressures necessary for inertial confinement fusion ignition, implosion experiments on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] require the compression of deuterium-tritium fuel layers by a convergence ratio as high as forty. Such high convergence implosions are subject to degradation by a range of perturbations, including the growth of small-scale defects due to hydrodynamic instabilities, as well as longer scale modulations due to radiation flux asymmetries in the enclosing hohlraum. Due to the broad range of scales involved, and also the genuinely three-dimensionalmore » (3D) character of the flow, accurately modeling NIF implosions remains at the edge of current simulation capabilities. This study describes the current state of progress of 3D capsule-only simulations of NIF implosions aimed at accurately describing the performance of specific NIF experiments. Current simulations include the effects of hohlraum radiation asymmetries, capsule surface defects, the capsule support tent and fill tube, and use a grid resolution shown to be converged in companion two-dimensional simulations. The results of detailed simulations of low foot implosions from the National Ignition Campaign are contrasted against results for more recent high foot implosions. While the simulations suggest that low foot performance was dominated by ablation front instability growth, especially the defect seeded by the capsule support tent, high foot implosions appear to be dominated by hohlraum flux asymmetries, although the support tent still plays a significant role. Finally, for both implosion types, the simulations show reasonable, though not perfect, agreement with the data and suggest that a reliable predictive capability is developing to guide future implosions toward ignition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, D. S.; Weber, C. R.; Milovich, J. L.
In order to achieve the several hundred Gbar stagnation pressures necessary for inertial confinement fusion ignition, implosion experiments on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] require the compression of deuterium-tritium fuel layers by a convergence ratio as high as forty. Such high convergence implosions are subject to degradation by a range of perturbations, including the growth of small-scale defects due to hydrodynamic instabilities, as well as longer scale modulations due to radiation flux asymmetries in the enclosing hohlraum. Due to the broad range of scales involved, and also the genuinely three-dimensionalmore » (3D) character of the flow, accurately modeling NIF implosions remains at the edge of current simulation capabilities. This paper describes the current state of progress of 3D capsule-only simulations of NIF implosions aimed at accurately describing the performance of specific NIF experiments. Current simulations include the effects of hohlraum radiation asymmetries, capsule surface defects, the capsule support tent and fill tube, and use a grid resolution shown to be converged in companion two-dimensional simulations. The results of detailed simulations of low foot implosions from the National Ignition Campaign are contrasted against results for more recent high foot implosions. While the simulations suggest that low foot performance was dominated by ablation front instability growth, especially the defect seeded by the capsule support tent, high foot implosions appear to be dominated by hohlraum flux asymmetries, although the support tent still plays a significant role. For both implosion types, the simulations show reasonable, though not perfect, agreement with the data and suggest that a reliable predictive capability is developing to guide future implosions toward ignition.« less
Clark, D. S.; Weber, C. R.; Milovich, J. L.; ...
2016-03-14
In order to achieve the several hundred Gbar stagnation pressures necessary for inertial confinement fusion ignition, implosion experiments on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] require the compression of deuterium-tritium fuel layers by a convergence ratio as high as forty. Such high convergence implosions are subject to degradation by a range of perturbations, including the growth of small-scale defects due to hydrodynamic instabilities, as well as longer scale modulations due to radiation flux asymmetries in the enclosing hohlraum. Due to the broad range of scales involved, and also the genuinely three-dimensionalmore » (3D) character of the flow, accurately modeling NIF implosions remains at the edge of current simulation capabilities. This study describes the current state of progress of 3D capsule-only simulations of NIF implosions aimed at accurately describing the performance of specific NIF experiments. Current simulations include the effects of hohlraum radiation asymmetries, capsule surface defects, the capsule support tent and fill tube, and use a grid resolution shown to be converged in companion two-dimensional simulations. The results of detailed simulations of low foot implosions from the National Ignition Campaign are contrasted against results for more recent high foot implosions. While the simulations suggest that low foot performance was dominated by ablation front instability growth, especially the defect seeded by the capsule support tent, high foot implosions appear to be dominated by hohlraum flux asymmetries, although the support tent still plays a significant role. Finally, for both implosion types, the simulations show reasonable, though not perfect, agreement with the data and suggest that a reliable predictive capability is developing to guide future implosions toward ignition.« less
Development of a gastroretentive pulsatile drug delivery platform.
Thitinan, Sumalee; McConville, Jason T
2012-04-01
To develop a novel gastroretentive pulsatile drug delivery platform by combining the advantages of floating dosage forms for the stomach and pulsatile drug delivery systems. A gastric fluid impermeable capsule body was used as a vessel to contain one or more drug layer(s) as well as one or more lag-time controlling layer(s). A controlled amount of air was sealed in the innermost portion of the capsule body to reduce the overall density of the drug delivery platform, enabling gastric floatation. An optimal mass fill inside the gastric fluid impermeable capsule body enabled buoyancy in a vertical orientation to provide a constant surface area for controlled erosion of the lag-time controlling layer. The lag-time controlling layer consisted of a swellable polymer, which rapidly formed a gel to seal the mouth of capsule body and act as a barrier to gastric fluid ingress. By varying the composition of the lag-time controlling layer, it was possible to selectively program the onset of the pulsatile delivery of a drug. This new delivery platform offers a new method of delivery for a variety of suitable drugs targeted in chronopharmaceutical therapy. This strategy could ultimately improve drug efficacy and patient compliance, and reduce harmful side effects by scaling back doses of drug administered. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.
Capsule performance optimization in the National Ignition Campaigna)
NASA Astrophysics Data System (ADS)
Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.
2010-05-01
A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.
Capsule performance optimization in the National Ignition Campaign
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landen, O. L.; Bradley, D. K.; Braun, D. G.
2010-05-15
A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition designmore » and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.« less
Dyksterhuis, L.D.; White, J.F.; Hickey, M.; Kirby, N.; Mudie, S.; Hawley, A.; Vashi, A.; Nigro, J.; Werkmeister, J.A.; Ramshaw, J.A.M.
2011-01-01
We assessed the importance of glycosaminoglycans and sulfur-mediated bonds for the mechanical properties of lens capsules by comparing the stress-strain responses from control and treated pairs of bovine source. No significant change in mechanical properties was observed upon reduction of disulfide bonds. However, removal of glycosaminoglycan chains resulted in a significantly stiffer lens capsule, whereas high concentrations of reducing agent, which is expected to reduce the recently reported sulfilimine bond of collagen IV, resulted in a significantly less stiff lens capsule. A comparison of the diffraction patterns of the control and strongly reduced lens capsules indicated structural rearrangements on a nanometer scale. PMID:21539774
Nanocomposite capsules with directional, pulsed nanoparticle release.
Udoh, Christiana E; Cabral, João T; Garbin, Valeria
2017-12-01
The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.
Kyrala, G A; Dixit, S; Glenzer, S; Kalantar, D; Bradley, D; Izumi, N; Meezan, N; Landen, O L; Callahan, D; Weber, S V; Holder, J P; Glenn, S; Edwards, M J; Bell, P; Kimbrough, J; Koch, J; Prasad, R; Suter, L; Kline, J L; Kilkenny, J
2010-10-01
Ignition of imploding inertial confinement capsules requires, among other things, controlling the symmetry with high accuracy and fidelity. We have used gated x-ray imaging, with 10 μm and 70 ps resolution, to detect the x-ray emission from the imploded core of symmetry capsules at the National Ignition Facility. The measurements are used to characterize the time dependent symmetry and the x-ray bang time of the implosion from two orthogonal directions. These measurements were one of the primary diagnostics used to tune the parameters of the laser and Hohlraum to vary the symmetry and x-ray bang time of the implosion of cryogenically cooled ignition scale deuterium/helium filled plastic capsules. Here, we will report on the successful measurements performed with up to 1.2 MJ of laser energy in a fully integrated cryogenics gas-filled ignition-scale Hohlraum and capsule illuminated with 192 smoothed laser beams. We will describe the technique, the accuracy of the technique, and the results of the variation in symmetry with tuning parameters, and explain how that set was used to predictably tune the implosion symmetry as the laser energy, the laser cone wavelength separation, and the Hohlraum size were increased to ignition scales. We will also describe how to apply that technique to cryogenically layered tritium-hydrogen-deuterium capsules.
Lauritzen, C; Reuter, H D; Repges, R; Böhnert, K J; Schmidt, U
1997-09-01
The objective of the present study was to determine the efficacy and tolerability of a new solid formulation (capsules) of Agnolyt®(*)) in a randomized, controlled trial versus pyridoxine in women with PMTS over a period of three treatment cycles (Vitex agnus castus (VAC): 1 capsule + 1 placebo capsule/day, n = 90; pyridoxine (B6): 2 capsules day, n = 85). The therapeutic response was assessed using the premenstrual tension syndrome scale (PMTS scale), the recording of six characteristic complaints of the syndrome, and the clinical global impression scale (CGI scale). Upon completion of the trial, efficacy of the treatment was assessed by the physician as well as by the patient. On the PMTS scale, treatment with VAC and B6 produced a reduction in score points from 15.2 to 5.1 (-47,4%) and from 11.9 to 5.1 (-48%)(*), respectively. In comparison with pyridoxine, VAC caused a considerably more marked alleviation of typical PMTS complaints, such as breast tenderness, edema, inner tension, headache, constipation, and depression. Analogous results were obtained with the CGI scale. In both treatment groups, efficacy was rated as at least adequate by more than 80% of the investigators; however, VAC treatment was rated as excellent by 24.5% and pyridoxine treatment by 12.1% of the investigators. According to the patients' assessment, 36.1% of the cases in the VAC group and 21.3% in the pyridoxine group were free from complaints. Adverse events (gastrointestinal and lower abdominal complaints, skin manifestations and transitory headache) occurred in 5 patients under B6 and in 12 patients under VAC. Serious adverse events were not observed. The results of the present study confirm the efficacy and safety of Agnolyt® capsules in the treatment of PMTS. Copyright © 1997 Gustav Fischer Verlag. Published by Elsevier GmbH.. All rights reserved.
Li, Hao; Yao, Ming-Jiang; Zhao, Wen-Ming; Guan, Jie; Cai, Lin-Lin; Cui, Ling
2008-01-01
To observe the effect and explore the mechanism of Huannao Yicong capsule in treating senile patients with mild cognitive impairment (MCI). The investigational drugs were packed by blind method. A randomized, double-blind and controlled trial was conducted on ninety senile patients with MCI. Other forty-five senile healthy persons were recruited to the healthy control group. The ninety senile patients were randomly divided into the Huannao Yicong capsule-treated group (45 patients administered with three Huannao Yicong capsules and two aniracetam capsule analogues) and aniracetam-treated group (45 patients treated with two aniracetam capsules and three Huannao Yicong capsule analogues). Patients in the two groups were treated three times daily for 16 weeks. Memory, traditional Chinese medicine syndrome, cerebral blood flow, free radicals and inflammatory mediators, such as superoxide dismutase (SOD), malondialdehyde (MDA), acetylcholinesterase (AchE), interleukin-1alpha (IL-1alpha) and interleukin-6 (IL-6) were determined before and after the treatment. Blood lipids, including triglyceride (TG), total cholesterol (TC), low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C), apolipoprotein A-1 (ApoA-1) and apolipoprotein B-100 (ApoB-100), were detected before and after the treatment. The safety indexes, such as routine tests of blood and urine, hepatic and renal function tests and electrocardiogram (ECG) were taken before and after the treatment. Index score of clinical memory scale in senile healthy people was significantly higher than that in MCI patients before treatment (P<0.01), and the content of AchE, IL-1alpha and IL-6 was obviously lower (P<0.01, P<0.05), the activity of SOD was higher (P<0.05). No significant difference was found in direction memory of clinical memory scale between the two treatment groups. Other index scores of clinical memory scale and traditional Chinese medicine syndrome in patients of Huannao Yicong capsule-treated group were significantly improved as compared with those of the aniracetam-treated group (P<0.05, P<0.01). The blood flow parameters of anterior cerebral artery, posterior cerebral artery and resistant index in patients of Huannao Yicong capsule-treated group were increased significantly (P<0.01, P<0.05). Huannao Yicong capsule could significantly increase the activity of serum SOD and decrease the content of AchE, IL-1alpha and IL-6 (P<0.01, P<0.05), better than aniracetam. Furthermore, Huannao Yicong capsule could significantly improve the blood lipid, such as the level of TG, LDL-C, HDL-C, ApoA-1 and ApoB-100 (P<0.01, P<0.05), and better than aniracetam (P<0.01, P<0.05). No significant changes were found after treatment in safety indexes, such as routine tests of blood and urine, hepatic and renal function tests and ECG. Huannao Yicong capsule has better therapeutic effect than aniracetam capsule in treating senile mild cognitive impairment.
Mitigate the tent-induced perturbation in ignition capsules by supersonic radiation propagation
NASA Astrophysics Data System (ADS)
Dai, Zhensheng; Gu, Jianfa; Zheng, Wudi
2017-10-01
In the inertial confinement fusion (ICF) scheme, to trap the alpha particle products of the D-T reaction, the capsules needs to be imploded and compressed with high symmetry In the laser indirect drive scheme, the capsules are held at the center of high-Z hohlraums by thin membranes (tents). However, the tents are recognized as one of the most important contributors to hot spot asymmetries, areal density perturbations and reduced performance. To improve the capsule implosion performance, various alternatives such as the micro-scale rods, a larger fill-tube and a low-density foam layer around the capsule have been presented. Our simulations show that the radiation propagates supersonically in the low-density foam layer and starts to ablate the capsule before the perturbations induced by the tents reach the ablating fronts. The tent induced perturbations are remarkably weakened when they are propagating in the blow-off plasma.
NASA Astrophysics Data System (ADS)
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.; Milovich, J.; Casey, D. T.; Weber, C. R.; Robey, H. F.; Chen, K.-C.; Clark, D. S.; Crippen, J.; Farrell, M.; Felker, S.; Field, J. E.; Haan, S. W.; Hammel, B. A.; Hamza, A. V.; Stadermann, M.; Hsing, W. W.; Kroll, J. J.; Landen, O. L.; Nikroo, A.; Pickworth, L.; Rice, N.
2017-10-01
Hydrodynamic instability growth of the capsule support membranes (or "tents") and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF) [Campbell et al., AIP Conf. Proc. 429, 3 (1998)]. In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new "sub-scale" version of the existing x-ray radiography platform was developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ˜2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ˜3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. The effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.
Safety of capsule endoscopy using human body communication in patients with cardiac devices.
Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young
2012-06-01
The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
AGR-2 Irradiation Test Final As-Run Report, Rev 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise P.
2014-08-01
This document presents the as-run analysis of the AGR-2 irradiation experiment. AGR-2 is the second of the planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the U.S. Department of Energy as part of the Very High Temperature Reactor (VHTR) Technical Development Office (TDO) program. The objectives of the AGR-2 experiment are to: (a) Irradiate UCO (uranium oxycarbide) and UO 2 (uranium dioxide) fuel produced in a large coater. Fuel attributes are based on results obtained from the AGR-1 test and other project activities. (b) Provide irradiated fuel samplesmore » for post-irradiation experiment (PIE) and safety testing. (c) Support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. The primary objective of the test was to irradiate both UCO and UO 2 TRISO (tri-structural isotropic) fuel produced from prototypic scale equipment to obtain normal operation and accident condition fuel performance data. The UCO compacts were subjected to a range of burnups and temperatures typical of anticipated prismatic reactor service conditions in three capsules. The test train also includes compacts containing UO 2 particles produced independently by the United States, South Africa, and France in three separate capsules. The range of burnups and temperatures in these capsules were typical of anticipated pebble bed reactor service conditions. The results discussed in this report pertain only to U.S. produced fuel. In order to achieve the test objectives, the AGR-2 experiment was irradiated in the B-12 position of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for a total irradiation duration of 559.2 effective full power days (EFPD). Irradiation began on June 22, 2010, and ended on October 16, 2013, spanning 12 ATR power cycles and approximately three and a half calendar years. The test contained six independently controlled and monitored capsules. Each U.S. capsule contained 12 compacts of either UCO or UO2 AGR coated fuel. No fuel particles failed during the AGR-2 irradiation. Final burnup values on a per compact basis ranged from 7.26 to 13.15% FIMA (fissions per initial heavy-metal atom) for UCO fuel, and 9.01 to 10.69% FIMA for UO 2 fuel, while fast fluence values ranged from 1.94 to 3.47 x 10 25 n/m 2 (E >0.18 MeV) for UCO fuel, and from 3.05 to 3.53 x 10 25 n/m 2 (E >0.18 MeV) for UO 2 fuel. Time-average volume-average (TAVA) temperatures on a capsule basis at the end of irradiation ranged from 987°C in Capsule 6 to 1296°C in Capsule 2 for UCO, and from 996 to 1062°C in UO 2-fueled Capsule 3. By the end of the irradiation, all of the installed thermocouples (TCs) had failed. Fission product release-to-birth (R/B) ratios were quite low. In the UCO capsules, R/B values during the first three cycles were below 10 -6 with the exception of the hotter Capsule 2, in which the R/Bs reached 2 x 10 -6. In the UO 2 capsule (Capsule 3), the R/B values during the first three cycles were below 10 -7. R/B values for all following cycles are not reliable due to gas flow and cross talk issues.« less
The national ignition facility and atomic data
NASA Astrophysics Data System (ADS)
Crandall, David H.
1998-07-01
The National Ignition Facility (NIF) is under construction, capping over 25 years of development of the inertial confinement fusion concept by providing the facility to obtain fusion ignition in the laboratory for the first time. The NIF is a 192 beam glass laser to provide energy controlled in space and time so that a millimeter-scale capsule containing deuterium and tritium can be compressed to fusion conditions. Light transport, conversion of light in frequency, interaction of light with matter in solid and plasma forms, and diagnostics of extreme material conditions on small scale all use atomic data in preparing for use of the NIF. The NIF will provide opportunity to make measurements of atomic data in extreme physical environments related to fusion energy, nuclear weapon detonation, and astrophysics. The first laser beams of NIF should be operational in 2001 and the full facility completed at the end of 2003. NIF is to provide 1.8 megajoule of blue light on fusion targets and is intended to achieve fusion ignition by about the end of 2007. Today's inertial fusion development activities use atomic data to design and predict fusion capsule performance and in non-fusion applications to analyze radiation transport and radiation effects on matter. Conditions investigated involve radiation temperature of hundreds of eV, pressures up to gigabars and time scales of femptoseconds.
Meredith, Alicea N; Harper, Bryan; Harper, Stacey L
2016-01-01
Encapsulation technology involves entrapping a chemical active ingredient (a.i.) inside a hollow polymeric shell and has been applied to commercial pesticide manufacturing for years to produce capsule suspension (CS) formulations with average particle sizes in the micron-scale. The few literature sources that investigate the environmental fate and toxicity to non-target organisms of encapsulated commercially available pesticide products with regard to capsule size report on average sizes between 20 and 50 μm. Here, we have identified a CS formulation with an average capsule size of approximately 2 μm with some capsules extending into the nanometer scale (~200 nm). Determining how carrier size influences toxicity is important to understanding if current pesticide risk assessments are sufficient to protect against products that incorporate encapsulation technology. Here, a commercial pyrethroid CS pesticide with lambda-cyhalothrin (λ-Cy) as the a.i. was separated into two suspensions, a fraction consisting of nano-sized capsules (~250 nm) and a fraction of micron-sized capsules (~2200 nm) in order to investigate the influence of capsule size on toxicity to embryonic zebrafish, Danio rerio. Toxicity was evaluated 24h after exposure to equivalent amounts of a.i. by the presence and severity of pyrethroid-specific tremors, 14 sublethal developmental impacts and mortality. Fish exposed to greater than 20 μg a.i. L(-1) technical λ-Cy or formulated product experienced curvature of the body axis, pericardial edema, craniofacial malformations, and mortality. Exposure to the unfractionated formulation, micro fraction, nano fraction and technical a.i. resulted in no significant differences in the occurrence of sublethal impacts or mortality; however, the technical a.i. exposure resulted in significantly less fish experiencing tremors and shorter tremors compared to any of the formulated product exposures. This suggests that the capsule size does not influence the toxic response of the entrapped λ-Cy, but the presence or absence of the capsules does. Testing across other encapsulated products is needed to determine if size does not have influence on toxicity regardless of encapsulation technology. Copyright © 2015 Elsevier Ltd. All rights reserved.
Su, Jiangli; Liu, Yang; Liu, Yu; Ren, Liqun
2015-01-01
To evaluate the long-term effectiveness of rivastigmine patch or capsule on mild to severe Alzheimer's disease (AD). We performed a meta-analysis of 17 studies regarding the treatment effectiveness of rivastigmine patch or capsule on mild-to-severe AD. Significant difference exists between treatment with rivastigmine patch or capsule and placebo groups (p-value < 0.001). In the Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) score evaluation, a negative weighted mean difference (WMD) was observed in overall and mild-moderate groups after rivastigmine treatment. And in ADAS-ADL score evaluation, a positive WMD was observed in overall groups after rivastigmine treatment. Moreover, WMD value is lower in patch administration subgroup compared to that of capsule administration subgroup. Rivastigmine treatment shows a positive result of improving the condition of patients with mild-to-severe AD. Patch administration shows a stronger effect on decreasing ADAS-Cog score compared to capsule administration.
Design and testing of tubular polymeric capsules for self-healing of concrete
NASA Astrophysics Data System (ADS)
Araújo, M.; Van Tittelboom, K.; Feiteira, J.; Gruyaert, E.; Chatrabhuti, S.; Raquez, J.-M.; Šavija, B.; Alderete, N.; Schlangen, E.; De Belie, N.
2017-10-01
Polymeric healing agents have proven their efficiency to heal cracks in concrete in an autonomous way. However, the bottleneck for valorisation of self-healing concrete with polymeric healing agents is their encapsulation. In the present work, the suitability of polymeric materials such as poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(lactic acid) (PLA) as carriers for healing agents in self-healing concrete has been evaluated. The durability of the polymeric capsules in different environments (demineralized water, salt water and simulated concrete pore solution) and their compatibility with various healing agents have been assessed. Next, a numerical model was used to simulate capsule rupture when intersected by a crack in concrete and validated experimentally. Finally, two real-scale self-healing concrete beams were made, containing the selected polymeric capsules (with the best properties regarding resistance to concrete mixing and breakage upon crack formation) or glass capsules and a reference beam without capsules. The self-healing efficiency was determined after crack creation by 3-point-bending tests.
Roach, Brandi; Silva, Marisela; Beck, Paul; Rioux, Kevin; Kaplan, Gilaad G.; Chang, Hsiu-Ju; Coward, Stephanie; Goodman, Karen J.; Xu, Huiping; Madsen, Karen; Mason, Andrew; Wong, Gane Ka-Shu; Jovel, Juan; Patterson, Jordan; Louie, Thomas
2017-01-01
Importance Fecal microbiota transplantation (FMT) is effective in preventing recurrent Clostridium difficile infection (RCDI). However, it is not known whether clinical efficacy differs by route of delivery. Objective To determine whether FMT by oral capsule is noninferior to colonoscopy delivery in efficacy. Design, Setting, and Participants Noninferiority, unblinded, randomized trial conducted in 3 academic centers in Alberta, Canada. A total of 116 adult patients with RCDI were enrolled between October 2014 and September 2016, with follow-up to December 2016. The noninferiority margin was 15%. Interventions Participants were randomly assigned to FMT by capsule or by colonoscopy at a 1:1 ratio. Main Outcomes and Measures The primary outcome was the proportion of patients without RCDI 12 weeks after FMT. Secondary outcomes included (1) serious and minor adverse events, (2) changes in quality of life by the 36-Item Short Form Survey on a scale of 0 (worst possible quality of life) to 100 (best quality of life), and (3) patient perception on a scale of 1 (not at all unpleasant) to 10 (extremely unpleasant) and satisfaction on a scale of 1 (best) to 10 (worst). Results Among 116 patients randomized (mean [SD] age, 58 [19] years; 79 women [68%]), 105 (91%) completed the trial, with 57 patients randomized to the capsule group and 59 to the colonoscopy group. In per-protocol analysis, prevention of RCDI after a single treatment was achieved in 96.2% in both the capsule group (51/53) and the colonoscopy group (50/52) (difference, 0%; 1-sided 95% CI, −6.1% to infinity; P < .001), meeting the criterion for noninferiority. One patient in each group died of underlying cardiopulmonary illness unrelated to FMT. Rates of minor adverse events were 5.4% for the capsule group vs 12.5% for the colonoscopy group. There was no significant between-group difference in improvement in quality of life. A significantly greater proportion of participants receiving capsules rated their experience as “not at all unpleasant” (66% vs 44%; difference, 22% [95% CI, 3%-40%]; P = .01). Conclusions and Relevance Among adults with RCDI, FMT via oral capsules was not inferior to delivery by colonoscopy for preventing recurrent infection over 12 weeks. Treatment with oral capsules may be an effective approach to treating RCDI. Trial Registration clinicaltrials.gov Identifier: NCT02254811 PMID:29183074
Bhatt, Bhavik; Kumar, Vijay
2016-08-25
In this article, we describe a method to utilize cellulose dissolved in dimethyl sulfoxide and paraformaldehyde solvent system to fabricate two-piece regenerated cellulose hard shell capsules for their potential use as an oral controlled drug delivery a priori vehicle. A systematic evaluation of solution rheology as well as resulting capsule mechanical, visual and thermal analysis was performed to develop a suitable method to repeatedly fabricate RC hard shell capsule halves. Because of the viscoelastic nature of the cellulose solution, a combination of dip-coating and casting method, herein referred to as dip-casting method, was developed. The dip-casting method was formalized by utilizing two-stage 2(2) full factorial design approach in order to determine a suitable approach to fabricate capsules with minimal variability. Thermal annealing is responsible for imparting shape rigidity of the capsules. Proof-of-concept analysis for the utility of these capsules in controlled drug delivery was performed by evaluating the release of KCl from them as well as from commercially available USP equivalent formulations. Release of KCl from cellulose capsules was comparable to extended release capsule formulation. Copyright © 2016 Elsevier B.V. All rights reserved.
Subsonic Dynamics of Stardust Sample Return Capsule
NASA Technical Reports Server (NTRS)
Mitcheltree, Robert A.; Fremaux, Charles M.
1997-01-01
Subsonic dynamic stability tests performed in the NASA Langley 20-Foot Vertical Spin-Tunnel on a 0.238 scale model of the Stardust Sample Return Capsule are discussed. The tests reveal that the blunted 60 degree half-angle cone capsule is dynamically unstable at low subsonic conditions due to the aft location of the center-of-gravity (0.351 body diameters back from the nose). The divergent behavior of the capsule continued when the center-of-gravity was moved to 0.337 and 0.313 body diameters back from the nose. When the center-of-gravity was moved further forward to 0.290 body diameters back from the nose, the vehicle established itself in a limit cycle with amplitude around 10 degrees. Two afterbody modifications were examined which proved unsuccessful in alleviating the instability of the original design. Finally, the addition of different sized parachutes was examined as a means to stabilize the vehicle. The parachute tests indicate that a parachute with equivalent full scale drag area of at least 2.24 ft. is necessary to assure large perturbations are damped.
NASA Photographer Prepares to Film a Mercury Capsule
1959-06-21
National Aeronautics and Space Administration (NASA) photographer Arthur Laufman sets up a camera to film a Mercury capsule that was constructed by the Lewis Research Center staff. Lewis engineers and mechanics built two of the capsules for the upcoming Big Joe launches in September 1959. Big Joe was an attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The Photographic Branch, referred to as the Photo Lab, was part of the center’s Technical Reports Division. Originally the group performed normal and high-speed still image and motion picture photography. The photographers documented construction, performed publicity work, created images for reports, photographed data on manometer boards, and recorded test footage. Laufman joined the Photo Lab staff in 1948 and began producing full-length technical films as a tool to educate those outside of the agency on the research being conducted at Lewis. He worked with engineers to determine proper subjects for these films and develop a script. Laufman not only filmed tests, but also supporting footage of facilities, models, and staff members. He then edited the footage and added audio, visuals, and narration. The film masters were assigned standard identification numbers and add to the Photo Lab’s catalogue.
Capsule Shimming Developments for National Ignition Facility (NIF) Hohlraum Asymmetry Experiments
Rice, Neal G.; Vu, M.; Kong, C.; ...
2017-12-20
Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less
Analytical model for effects of capsule shape on the healing efficiency in self-healing materials
Li, Songpeng; Chen, Huisu
2017-01-01
The fundamental requirement for the autonomous capsule-based self-healing process to work is that cracks need to reach the capsules and break them such that the healing agent can be released. Ignoring all other aspects, the amount of healing agents released into the crack is essential to obtain a good healing. Meanwhile, from the perspective of the capsule shapes, spherical or elongated capsules (hollow tubes/fibres) are the main morphologies used in capsule-based self-healing materials. The focus of this contribution is the description of the effects of capsule shape on the efficiency of healing agent released in capsule-based self-healing material within the framework of the theory of geometrical probability and integral geometry. Analytical models are developed to characterize the amount of healing agent released per crack area from capsules for an arbitrary crack intersecting with capsules of various shapes in a virtual capsule-based self-healing material. The average crack opening distance is chosen to be a key parameter in defining the healing potential of individual cracks in the models. Furthermore, the accuracy of the developed models was verified by comparison to the data from a published numerical simulation study. PMID:29095862
NASA Astrophysics Data System (ADS)
Lv, Zhong; Chen, Huisu
2014-10-01
Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance.
Kim, J S; Sung, I H; Kim, Y T; Kim, D E; Jang, Y H
2007-11-01
For the purpose of optimizing the design of the locomotion mechanism as well as the body shape of a self-propelled capsule endoscope, an analytical model for the prediction of frictional resistance of the capsule moving inside the small intestine was first developed. The model was developed by considering the contact geometry and viscoelasticity of the intestine, based on the experimental investigations on the material properties of the intestine and the friction of the capsule inside the small intestine. In order to verify the model and to investigate the distributions of various stress components applied to the capsule, finite element (FE) analyses were carried out. The comparison of the frictional resistance between the predicted and the experimental values suggested that the proposed model could predict the frictional force of the capsule with reasonable accuracy. Also, the FE analysis results of various stress components revealed the stress relaxation of the intestine and explained that such stress relaxation characteristics of the intestine resulted in lower frictional force as the speed of the capsule decreased. These results suggested that the frontal shape of the capsule was critical to the design of the capsule with desired frictional performance. It was shown that the proposed model can provide quantitative estimation of the frictional resistance of the capsule under various moving conditions inside the intestine. The model is expected to be useful in the design optimization of the capsule locomotion inside the intestine.
Development of glia and blood vessels in the internal capsule of rats.
Earle, K L; Mitrofanis, J
1998-02-01
We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified microglia are seen in the thalamus. In summary, our results indicate that all three types of glia in the internal capsule are associated closely with the vasculature, suggesting they may play a role in the development of the blood-brain barrier among the vessels in this white matter region of the forebrain.
High-resolution 3D simulations of NIF ignition targets performed on Sequoia with HYDRA
NASA Astrophysics Data System (ADS)
Marinak, M. M.; Clark, D. S.; Jones, O. S.; Kerbel, G. D.; Sepke, S.; Patel, M. V.; Koning, J. M.; Schroeder, C. R.
2015-11-01
Developments in the multiphysics ICF code HYDRA enable it to perform large-scale simulations on the Sequoia machine at LLNL. With an aggregate computing power of 20 Petaflops, Sequoia offers an unprecedented capability to resolve the physical processes in NIF ignition targets for a more complete, consistent treatment of the sources of asymmetry. We describe modifications to HYDRA that enable it to scale to over one million processes on Sequoia. These include new options for replicating parts of the mesh over a subset of the processes, to avoid strong scaling limits. We consider results from a 3D full ignition capsule-only simulation performed using over one billion zones run on 262,000 processors which resolves surface perturbations through modes l = 200. We also report progress towards a high-resolution 3D integrated hohlraum simulation performed using 262,000 processors which resolves surface perturbations on the ignition capsule through modes l = 70. These aim for the most complete calculations yet of the interactions and overall impact of the various sources of asymmetry for NIF ignition targets. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.
1959-09-08
Big Joe Capsule Launch Pad Activities: This film covers both the Big Joe and a Little Joe Project Mercury flight test with a research and development version of the Mercury capsule. Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959. The lower half of the capsule was created at NASA Lewis. The scenes include coverage of the assembly and erection of the boosters, delivery of the capsules, mating of the capsules to the boosters, prelaunch views of the capsule and boosters on launchers, mission control, the launches, and recovery.
Visualization of Capsule Reentry Vehicle Heat Shield Ablation Using Naphthalene PLIF
NASA Technical Reports Server (NTRS)
Combs, Christopher S.; Clemens, Noel T.; Danehy, Paul M.
2014-01-01
The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield and improved understanding of the ablation process would be beneficial for design purposes. Given that ablation is a multi-physics process involving heat and mass transfer, codes aiming to predict heat shield ablation are in need of experimental data pertaining to the turbulent transport of ablation products for validation. At The University of Texas at Austin, a technique is being developed that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to visualize the transport of ablation products in a supersonic flow. Since ablation at reentry temperatures can be difficult to recreate in a laboratory setting it is desirable to create a limited physics problem and simulate the ablation process at relatively low temperature conditions using naphthalene. A scaled Orion MPCV model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel at various angles of attack in the current work. PLIF imaging reveals the distribution of the ablation products as they are transported into the heat-shield boundary layer and over the capsule shoulders into the separated shear layer and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. High concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure were observed using the naphthalene PLIF technique. The capsule shear layer was also shown to generally appear to be more turbulent at lower angles of attack. Furthermore, the PLIF signal increased steadily over the course of a run indicating that during a wind tunnel run the model heated up and the rate of naphthalene ablation increased. The shear layer showed increasing signs of turbulence over the course of a wind tunnel run as well, likely because of the combination of increased surface roughness and surface blowing rate. PLIF imaging also detected regions with a relatively low concentration of naphthalene in the capsule backshell recirculation region that are most likely the result of cross-flow-induced vortices on the capsule afterbody.
The physics basis for ignition using indirect-drive targets on the National Ignition Facility
NASA Astrophysics Data System (ADS)
Lindl, John D.; Amendt, Peter; Berger, Richard L.; Glendinning, S. Gail; Glenzer, Siegfried H.; Haan, Steven W.; Kauffman, Robert L.; Landen, Otto L.; Suter, Laurence J.
2004-02-01
The 1990 National Academy of Science final report of its review of the Inertial Confinement Fusion Program recommended completion of a series of target physics objectives on the 10-beam Nova laser at the Lawrence Livermore National Laboratory as the highest-priority prerequisite for proceeding with construction of an ignition-scale laser facility, now called the National Ignition Facility (NIF). These objectives were chosen to demonstrate that there was sufficient understanding of the physics of ignition targets that the laser requirements for laboratory ignition could be accurately specified. This research on Nova, as well as additional research on the Omega laser at the University of Rochester, is the subject of this review. The objectives of the U.S. indirect-drive target physics program have been to experimentally demonstrate and predictively model hohlraum characteristics, as well as capsule performance in targets that have been scaled in key physics variables from NIF targets. To address the hohlraum and hydrodynamic constraints on indirect-drive ignition, the target physics program was divided into the Hohlraum and Laser-Plasma Physics (HLP) program and the Hydrodynamically Equivalent Physics (HEP) program. The HLP program addresses laser-plasma coupling, x-ray generation and transport, and the development of energy-efficient hohlraums that provide the appropriate spectral, temporal, and spatial x-ray drive. The HEP experiments address the issues of hydrodynamic instability and mix, as well as the effects of flux asymmetry on capsules that are scaled as closely as possible to ignition capsules (hydrodynamic equivalence). The HEP program also addresses other capsule physics issues associated with ignition, such as energy gain and energy loss to the fuel during implosion in the absence of alpha-particle deposition. The results from the Nova and Omega experiments approach the NIF requirements for most of the important ignition capsule parameters, including drive temperature, drive symmetry, and hydrodynamic instability. This paper starts with a review of the NIF target designs that have formed the motivation for the goals of the target physics program. Following that are theoretical and experimental results from Nova and Omega relevant to the requirements of those targets. Some elements of this work were covered in a 1995 review of indirect-drive [J. D. Lindl, ``Development of the indirect-drive approach to inertial confinement fusion and the target physics basis for ignition and gain,'' Phys. Plasmas 2, 3933 (1995)]. In order to present as complete a picture as possible of the research that has been carried out on indirect drive, key elements of that earlier review are also covered here, along with a review of work carried out since 1995.
NASA Astrophysics Data System (ADS)
Haines, Brian; Olson, Richard; Yi, Austin; Zylstra, Alex; Peterson, Robert; Bradley, Paul; Shah, Rahul; Wilson, Doug; Kline, John; Leeper, Ramon; Batha, Steve
2017-10-01
The high convergence ratio (CR) of layered Inertial Confinement Fusion capsule implosions contribute to high performance in 1D simulations yet make them more susceptible to hydrodynamic instabilities, contributing to the development of 3D flows. The wetted foam platform is an approach to hot spot ignition to achieve low-to-moderate convergence ratios in layered implosions on the NIF unobtainable using an ice layer. Detailed high-resolution modeling of these experiments in 2D and 3D, including all known asymmetries, demonstrates that 2D hydrodynamics explain capsule performance at CR 12 but become less suitable as the CR increases. Mechanisms for this behavior and detailed comparisons of simulations to experiments on NIF will be presented. To evaluate the tradeoff between increased instability and improved 1D performance, we present a full-scale wetted foam capsule design with 17
Cluster Development Test 2: An Assessment of a Failed Test
NASA Technical Reports Server (NTRS)
Machin, Ricardo A.; Evans, Carol T.
2009-01-01
On 31 July 2008 the National Aeronautics and Space Administration Crew Exploration Vehicle Parachute Assembly System team conducted the final planned cluster test of the first generation parachute recovery system design. The two primary test objectives were to demonstrate the operation of the complete parachute system deployed from a full scale capsule simulator and to demonstrate the test technique of separating the capsule simulator from the Low Velocity Air Drop pallet used to extract the test article from a United States Air Force C-17 aircraft. The capsule simulator was the Parachute Test Vehicle with an accurate heat shield outer mold line and forward bay compartment of the Crew Exploration Vehicle Command Module. The Parachute Test Vehicle separated cleanly from the pallet following extraction, but failed to reach test conditions resulting in the failure of the test and the loss of the test assets. No personnel were injured. This paper will discuss the design of the test and the findings of the team that investigated the test, including a discussion of what were determined to be the root causes of the failure.
A locomotion mechanism with external magnetic guidance for active capsule endoscope.
Wang, Xiaona; Meng, Max Q H; Chen, Xijun
2010-01-01
Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.
Primate lens capsule elasticity assessed using Atomic Force Microscopy
Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie
2011-01-01
The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Séguin, F. H.; Li, C. K.; DeCiantis, J. L.
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seguin, F. H.; Li, C. K.; DeCiantis, J. L.
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Furthermore, measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
Seguin, F. H.; Li, C. K.; DeCiantis, J. L.; ...
2016-03-22
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Furthermore, measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
Scaling laws for ignition at the National Ignition Facility from first principles.
Cheng, Baolian; Kwan, Thomas J T; Wang, Yi-Ming; Batha, Steven H
2013-10-01
We have developed an analytical physics model from fundamental physics principles and used the reduced one-dimensional model to derive a thermonuclear ignition criterion and implosion energy scaling laws applicable to inertial confinement fusion capsules. The scaling laws relate the fuel pressure and the minimum implosion energy required for ignition to the peak implosion velocity and the equation of state of the pusher and the hot fuel. When a specific low-entropy adiabat path is used for the cold fuel, our scaling laws recover the ignition threshold factor dependence on the implosion velocity, but when a high-entropy adiabat path is chosen, the model agrees with recent measurements.
Capsule endoscopy: no longer limited to the small bowel.
Niv, Yaron
2010-03-01
Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.
The presence and influence of posterior capsule tightness on different shoulder problems.
Duzgun, Irem; Turgut, Elif; Çinar-Medeni, Özge; Kafa, Nihan; Tuna, Zeynep; Elbasan, Bulent; Oskay, Deran
2017-01-01
In the literature it has been shown that posterior capsule flexibility is a precursor to shoulder problems. However, no study thus far has shown the influence of the flexibility of posterior capsule in different shoulder pathologies. This study set about to compare the role of posterior capsule tightness in different shoulder problems. One-hundred-twenty-five patients diagnosed with shoulder subacromial impingement syndrome (n= 52), partial rotator cuff tear (n= 31) or frozen shoulder (n= 42) and 30 asymptomatic peers participated in the study. Horizontal adduction was assessed in side-lying position for posterior capsule tightness. Pain was measured via the visual analogue scale and shoulder range of motion and active total elevation was assessed with goniometer. Hand behind the back (HBB) test was assessed the active internal rotation by measuring the distance between T5 and the thumb. It was found that the affected side of the posterior capsules of the patients with subacromial impingement syndrome (p< 0.001), partial rotator cuff tear (p< 0.001) and frozen shoulder (p< 0.001) was stiffer than their healthy side. There were significant differences among groups in the level of tightness in the posterior capsule between the affected and the healthy sides (p< 0.001). All range of motion of the shoulder including HBB test and the posterior capsule tightness of the affected side are found to be correlated (p< 0.05). This study emphasized that the posterior capsule's susceptibility to tightness is most evident in frozen shoulder among different shoulder problems.
Sensor capsule for diagnosis of gastric disorders
NASA Technical Reports Server (NTRS)
Holen, J. T.
1972-01-01
Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.
Using Numerical Modeling to Simulate Space Capsule Ground Landings
NASA Technical Reports Server (NTRS)
Heymsfield, Ernie; Fasanella, Edwin L.
2009-01-01
Experimental work is being conducted at the National Aeronautics and Space Administration s (NASA) Langley Research Center (LaRC) to investigate ground landing capabilities of the Orion crew exploration vehicle (CEV). The Orion capsule is NASA s replacement for the Space Shuttle. The Orion capsule will service the International Space Station and be used for future space missions to the Moon and to Mars. To evaluate the feasibility of Orion ground landings, a series of capsule impact tests are being performed at the NASA Langley Landing and Impact Research Facility (LandIR). The experimental results derived at LandIR provide means to validate and calibrate nonlinear dynamic finite element models, which are also being developed during this study. Because of the high cost and time involvement intrinsic to full-scale testing, numerical simulations are favored over experimental work. Subsequent to a numerical model validated by actual test responses, impact simulations will be conducted to study multiple impact scenarios not practical to test. Twenty-one swing tests using the LandIR gantry were conducted during the June 07 through October 07 time period to evaluate the Orion s impact response. Results for two capsule initial pitch angles, 0deg and -15deg , along with their computer simulations using LS-DYNA are presented in this article. A soil-vehicle friction coefficient of 0.45 was determined by comparing the test stopping distance with computer simulations. In addition, soil modeling accuracy is presented by comparing vertical penetrometer impact tests with computer simulations for the soil model used during the swing tests.
Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.
Mapara, Sanyat S; Patravale, Vandana B
2017-09-10
The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been highlighted. Copyright © 2017 Elsevier B.V. All rights reserved.
Intracerebral hemorrhage location and outcome among INTERACT2 participants.
Delcourt, Candice; Sato, Shoichiro; Zhang, Shihong; Sandset, Else Charlotte; Zheng, Danni; Chen, Xiaoying; Hackett, Maree L; Arima, Hisatomi; Hata, Jun; Heeley, Emma; Al-Shahi Salman, Rustam; Robinson, Thompson; Davies, Leo; Lavados, Pablo M; Lindley, Richard I; Stapf, Christian; Chalmers, John; Anderson, Craig S
2017-04-11
To clarify associations between intracerebral hemorrhage (ICH) location and clinical outcomes among participants of the main phase Intensive Blood Pressure Reduction in Acute Cerebral Hemorrhage Trial (INTERACT2). Associations between ICH sites and poor outcomes (death [6] or major disability [3-5] of modified Rankin Scale) and European Quality of Life Scale (EQ-5D) utility scores at 90 days were assessed in logistic regression models. Of 2,066 patients included in the analyses, associations were identified between ICH sites and poor outcomes: involvement of posterior limb of internal capsule increased risks of death or major disability (odds ratio [OR] 2.10) and disability (OR 1.81); thalamic involvement increased risks of death or major disability (OR 2.24) and death (OR 1.97). Involvement of the posterior limb of the internal capsule, thalamus, and infratentorial sites were each associated with poor EQ-5D utility score (≤0.7 [median]; OR 1.87, 2.14, and 2.81, respectively). Posterior limb of internal capsule involvement was strongly associated with low scores across all health-related quality of life domains. ICH encompassing the thalamus and posterior limb of internal capsule were associated with death or major disability, major disability, and poor EQ-5D utility score (OR 1.72, 2.26, and 1.71, respectively). Poor clinical outcomes are related to ICH affecting the posterior limb of internal capsule, thalamus, and infratentorial sites. The highest association with death or major disability and poor EQ-5D utility score was seen in ICH encompassing the thalamus and posterior limb of internal capsule. NCT00716079. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
Pant, C. R.; Pokharel, G. P.; Curtale, F.; Pokhrel, R. P.; Grosse, R. N.; Lepkowski, J.; Muhilal; Bannister, M.; Gorstein, J.; Pak-Gorstein, S.; Atmarita; Tilden, R. L.
1996-01-01
The impact on vitamin A deficiency (VAD), wasting malnutrition, and excessive childhood mortality of two alternative approaches-nutrition education and mega-dose capsule distribution (6-12-month-olds: 100,000 IU; 1-5-year-olds: 200,000 IU)-in communities in Nepal are compared. Approximately 40,000 children from 75 locations in seven districts in two ecological settings (lowland and hills) took part in the study and were randomly allocated to intervention cohorts or a control group. At 24 months after the implementation of the project the reduction of risk for xerophthalmia was greater among children whose mothers were able to identify vitamin-A-rich foods (relative risk (RR) = 0.25; 95% confidence interval (CI) = 0.10-0.62) than among the children who received mega-dose capsules (RR = 0.59; 95% CI = 0.41-0.84). The risk of mortality at 2 years was reduced for both the nutrition education (RR = 0.64; 95% Cl = 0.48-0.86) and capsule distribution (RR = 0.57; 95% CI = 0.42-0.77) cohorts. The nutrition education programme was, however, more expensive to deliver than the capsule distribution programme. High rates of participation for children in the supplementation programme were achieved quickly. The nutrition education messages also spread rapidly throughout the study population (regardless of intervention cohort assignment). Practices, however, were slower to change. In communities where maternal literacy was low and channels of communication were limited the capsule distribution programme appeared to be more economical. However, there are economies of scale for nationwide education programmes that do not exist for capsule distribution programmes. Although nutrition education provides economies of scale and the promise of long-term sustainability, a comprehensive national programme requires both dietary supplementation and nutrition education components. PMID:9002334
Process Development and Micro-Machining of MARBLE Foam-Cored Rexolite Hemi-Shell Ablator Capsules
Randolph, Randall Blaine; Oertel, John A.; Schmidt, Derek William; ...
2016-06-30
For this study, machined CH hemi-shell ablator capsules have been successfully produced by the MST-7 Target Fabrication Team at Los Alamos National Laboratory. Process development and micro-machining techniques have been developed to produce capsules for both the Omega and National Ignition Facility (NIF) campaigns. These capsules are gas filled up to 10 atm and consist of a machined plastic hemi-shell outer layer that accommodates various specially engineered low-density polystyrene foam cores. Machining and assembly of the two-part, step-jointed plastic hemi-shell outer layer required development of new techniques, processes, and tooling while still meeting very aggressive shot schedules for both campaigns.more » Finally, problems encountered and process improvements will be discussed that describe this very unique, complex capsule design approach through the first Omega proof-of-concept version to the larger NIF version.« less
Khan, Tareq; Shrestha, Ravi; Imtiaz, Md. Shamin
2015-01-01
Presented is a new power-efficient colour generation algorithm for wireless capsule endoscopy (WCE) application. In WCE, transmitting colour image data from the human intestine through radio frequency (RF) consumes a huge amount of power. The conventional way is to transmit all R, G and B components of all frames. Using the proposed dictionary-based colour generation scheme, instead of sending all R, G and B frames, first one colour frame is sent followed by a series of grey-scale frames. At the receiver end, the colour information is extracted from the colour frame and then added to colourise the grey-scale frames. After a certain number of grey-scale frames, another colour frame is sent followed by the same number of grey-scale frames. This process is repeated until the end of the video sequence to maintain the colour similarity. As a result, over 50% of RF transmission power can be saved using the proposed scheme, which will eventually lead to a battery life extension of the capsule by 4–7 h. The reproduced colour images have been evaluated both statistically and subjectively by professional gastroenterologists. The algorithm is finally implemented using a WCE prototype and the performance is validated using an ex-vivo trial. PMID:26609405
Emerging Issues and Future Developments in Capsule Endoscopy
Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro
2015-01-01
Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956
NASA Astrophysics Data System (ADS)
Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.
2012-03-01
To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.
NASA Astrophysics Data System (ADS)
Smith, Kathryn E.; Thatje, Sven
2013-03-01
Intracapsular development is common in marine gastropods. In many species, embryos develop alongside nurse eggs, which provide nutrition during ontogeny. The common whelk Buccinum undatum is a commercially important North Atlantic shallow-water gastropod. Development is intracapsular in this species, with individuals hatching as crawling juveniles. While its reproductive cycle has been well documented, further work is necessary to provide a complete description of encapsulated development. Here, using B. undatum egg masses from the south coast of England intracapsular development at 6 °C is described. Number of eggs, veligers and juveniles per capsule are compared, and nurse egg partitioning, timing of nurse egg consumption and intracapsular size differences through development are discussed. Total development took between 133 and 140 days, over which 7 ontogenetic stages were identified. The number of both eggs and veligers were significantly related to capsule volume, with approximately 1 % of eggs developing per capsule. Each early veliger consumed nurse eggs rapidly over just 3-7 days. Within each capsule, initial development was asynchronous, but it became synchronous during the veliger stage. No evidence for cannibalism was found during development, but large size differences between embryos developing within each capsule were observed, and occasionally `empty' veligers were seen, which had not successfully consumed any nurse eggs. These results indicate a high level of competition for nurse eggs within each capsule during development in the common whelk. The initial differences observed in nurse egg uptake may affect individual predisposition in later life.
New designs of LMJ targets for early ignition experiments
NASA Astrophysics Data System (ADS)
C-Clérouin, C.; Bonnefille, M.; Dattolo, E.; Fremerye, P.; Galmiche, D.; Gauthier, P.; Giorla, J.; Laffite, S.; Liberatore, S.; Loiseau, P.; Malinie, G.; Masse, L.; Poggi, F.; Seytor, P.
2008-05-01
The LMJ experimental plans include the attempt of ignition and burn of an ICF capsule with 40 laser quads, delivering up to 1.4MJ and 380TW. New targets needing reduced laser energy with only a small decrease in robustness are then designed for this purpose. A first strategy is to use scaled-down cylindrical hohlraums and capsules, taking advantage of our better understanding of the problem, set on theoretical modelling, simulations and experiments. Another strategy is to work specifically on the coupling efficiency parameter, i.e. the ratio of the energy absorbed by the capsule to the laser energy, which is with parametric instabilities a crucial drawback of indirect drive. An alternative design is proposed, made up of the nominal 60 quads capsule, named A1040, in a rugby-shaped hohlraum. Robustness evaluations of these different targets are in progress.
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. Here, we propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method usesmore » a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT "clean" and DT "mix" gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. Furthermore, we observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λ ii~T 2/Z 2ρ at the gas/shell interface. Finally, since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.« less
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.; ...
2016-05-26
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. Here, we propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method usesmore » a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT "clean" and DT "mix" gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. Furthermore, we observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λ ii~T 2/Z 2ρ at the gas/shell interface. Finally, since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.« less
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
NASA Astrophysics Data System (ADS)
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.; McEvoy, A. M.; Zylstra, A.; Hammel, B. A.; Sepke, S. M.; Leatherland, A.; Gales, S.
2016-05-01
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. We propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method uses a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT “clean” and DT “mix” gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. An experiment to observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λii∼T2/Z2ρ at the gas/shell interface. Since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.
Kazakova, Lyubov I; Shabarchina, Lyudmila I; Anastasova, Salzitsa; Pavlov, Anton M; Vadgama, Pankaj; Skirtach, Andre G; Sukhorukov, Gleb B
2013-02-01
The concept of enzyme-assisted substrate sensing based on use of fluorescent markers to detect the products of enzymatic reaction has been investigated by fabrication of micron-scale polyelectrolyte capsules containing enzymes and dyes in one entity. Microcapsules approximately 5 μm in size entrap glucose oxidase or lactate oxidase, with peroxidase, together with the corresponding markers Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride (Ru(dpp)) complex and dihydrorhodamine 123 (DHR123), which are sensitive to oxygen and hydrogen peroxide, respectively. These capsules are produced by co-precipitation of calcium carbonate particles with the enzyme followed by layer-by-layer assembly of polyelectrolytes over the surface of the particles and incorporation of the dye in the capsule interior or in the multilayer shell. After dissolution of the calcium carbonate the enzymes and dyes remain in the multilayer capsules. In this study we produced enzyme-containing microcapsules sensitive to glucose and lactate. Calibration curves based on fluorescence intensity of Ru(dpp) and DHR123 were linearly dependent on substrate concentration, enabling reliable sensing in the millimolar range. The main advantages of using these capsules with optical recording is the possibility of building single capsule-based sensors. The response from individual capsules was observed by confocal microscopy as increasing fluorescence intensity of the capsule on addition of lactate at millimolar concentrations. Because internalization of the micron-sized multi-component capsules was feasible, they could be further optimized for in-situ intracellular sensing and metabolite monitoring on the basis of fluorescence reporting.
Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment
Do, Thanh Nho; Seah, Tian En Timothy; Yu, Ho Khek; Phee, Soo Jay
2016-01-01
Intra-gastric balloons (IGB) have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient’s stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient’s stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm) is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight. PMID:26815309
Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.
Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi
2014-08-07
Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.
Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao
2017-08-01
Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.
AFRRI Reports, April-June 1990
1990-07-01
described in detail in the companion paper (4). In vivo dosimetry was done using Harshaw (Solon, Ohio) TLD -100 lith- ium fluoride thermoluminescent...provide replicate measurements. Two separate dosimetry tubes were developed (Fig. 1). The first contained 30 TLD cap- sules loaded in a 90-cm length...situ Dosimetry Tube 55 3 LIF TLDs In gelatin capsule TUBEB LIF TLDs Nylon Balls Steel Ball Epoxy Plug I Scale 3 cm - J FIG. I
Zhou, Weizheng; Tong, Gangsheng; Wang, Dali; Zhu, Bangshang; Ren, Yu; Butler, Michael; Pelan, Eddie; Yan, Deyue; Zhu, Xinyuan; Stoyanov, Simeon D
2016-04-06
Hierarchical porous structures are ubiquitous in biological organisms and inorganic systems. Although such structures have been replicated, designed, and fabricated, they are often inferior to naturally occurring analogues. Apart from the complexity and multiple functionalities developed by the biological systems, the controllable and scalable production of hierarchically porous structures and building blocks remains a technological challenge. Herein, a facile and scalable approach is developed to fabricate hierarchical hollow spheres with integrated micro-, meso-, and macropores ranging from 1 nm to 100 μm (spanning five orders of magnitude). (Macro)molecules, micro-rods (which play a key role for the creation of robust capsules), and emulsion droplets have been successfully employed as multiple length scale templates, allowing the creation of hierarchical porous macrospheres. Thanks to their specific mechanical strength, these hierarchical porous spheres could be incorporated and assembled as higher level building blocks in various novel materials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Experimental measurement on movement of spiral-type capsule endoscope
Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing
2016-01-01
Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279
Experimental measurement on movement of spiral-type capsule endoscope.
Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing
2016-01-01
Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.
Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth
2013-01-01
Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD < 1.5 µm, FPF<5µm/ED > 90%, and ED > 80%. PMID:23949304
Capsule implosion optimization during the indirect-drive National Ignition Campaign
NASA Astrophysics Data System (ADS)
Landen, O. L.; Edwards, J.; Haan, S. W.; Robey, H. F.; Milovich, J.; Spears, B. K.; Weber, S. V.; Clark, D. S.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.; Atherton, J.; Amendt, P. A.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Frenje, J. A.; Glenzer, S. H.; Hamza, A.; Hammel, B. A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kilkenny, J. D.; Kirkwood, R. K.; Kline, J. L.; Kyrala, G. A.; Marinak, M. M.; Meezan, N.; Meyerhofer, D. D.; Michel, P.; Munro, D. H.; Olson, R. E.; Nikroo, A.; Regan, S. P.; Suter, L. J.; Thomas, C. A.; Wilson, D. C.
2011-05-01
Capsule performance optimization campaigns will be conducted at the National Ignition Facility [G. H. Miller, E. I. Moses, and C. R. Wuest, Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition. The campaigns will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models using a variety of ignition capsule surrogates before proceeding to cryogenic-layered implosions and ignition experiments. The quantitative goals and technique options and down selections for the tuning campaigns are first explained. The computationally derived sensitivities to key laser and target parameters are compared to simple analytic models to gain further insight into the physics of the tuning techniques. The results of the validation of the tuning techniques at the OMEGA facility [J. M. Soures et al., Phys. Plasmas 3, 2108 (1996)] under scaled hohlraum and capsule conditions relevant to the ignition design are shown to meet the required sensitivity and accuracy. A roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget. Finally, we show how the tuning precision will be improved after a number of shots and iterations to meet an acceptable level of residual uncertainty.
Chuang, Chi-Hung; Porel, Mintu; Choudhury, Rajib; Burda, Clemens; Ramamurthy, V
2018-01-11
Results of our study on ultrafast electron transfer (eT) dynamics from coumarins (coumarin-1, coumarin-480, and coumarin-153) incarcerated within octa acid (OA) capsules as electron donors to methyl viologen dissolved in water as acceptor are presented. Upon photoexcitation, coumarin inside the OA capsule transfers an electron to the acceptor electrostatically attached to the capsule leading to a long-lived radical-ion pair separated by the OA capsular wall. This charge-separated state returns to the neutral ground state via back electron transfer on the nanosecond time scale. This system allows for ultrafast electron transfer processes through a molecular wall from the apolar capsular interior to the highly polar (aqueous) environment on the femtosecond time scale. Employing femtosecond transient absorption spectroscopy, distinct rates of both forward (1-25 ps) and backward eT (700-1200 ps) processes were measured. Further understanding of the energetics is provided using Rehm-Weller analysis for the investigated photoinduced eT reactions. The results provide the rates of the eT across a molecular wall, akin to an isotropic solution, depending on the standard free energy of the reaction. The insights from this work could be utilized in the future design of efficient electron transfer processes across interfaces separating apolar and polar environments.
What measurements of proton self emission tell us about hohlraum fields and yield anomalies
NASA Astrophysics Data System (ADS)
Petrasso, R.; Li, C.; Seguin, F.; Frenje, J.; Rosenberg, M.; Rinderknecht, H.; Philippe, F.; Casner, A.; Caillaud, T.; Landoas, O.; Bourgade, J.-L.; Amendt, P.; Izumi, N.; Koch, J.; Landen, O.; Milovich, J.; Park, H.; Robey, H.; Robey, R.; Town, R.; Nikroo, A.; Kilkenny, J.
2009-11-01
Measurements have been made of 14.7-MeV self-emission protons, from reactions of D-3He fuel, for a variety of hohlraums - scale 1 and scale .5ex3 -.1em/ -.15em.25ex3 , gold and cocktail hohlraums, vacuum and gas-filled hohlraums, cylindrical and rugby geometries, drive with and without phase plates, drive with different numbers of beams, and implosions with different capsule parameters. The picture that emerges is quite consistent: large anisotropies in the proton fluence pattern are generally observed out the LEH but little if any variations through the hohlraum equator. In addition, we examine whether the scaling of yields from pure D2 to D-3He mixtures is found to deviate from the expected density scaling (i.e. the Rygg Effect), as reported recently for directly driven capsules (1). (1) H. Herrmann et al., PoP 16, 056312(2009)
A new symmetry model for hohlraum-driven capsule implosion experiments on the NIF
NASA Astrophysics Data System (ADS)
Jones, O.; Rygg, R.; Tomasini, R.; Eder, D.; Kritcher, A.; Milovich, J.; Peterson, L.; Thomas, C.; Barrios, M.; Benedetti, R.; Doeppner, T.; Ma, T.; Nagel, S.; Pak, A.; Field, J.; Izumi, N.; Glenn, S.; Town, R.; Bradley, D.
2016-03-01
We have developed a new model for predicting the time-dependent radiation drive asymmetry in laser-heated hohlraums. The model consists of integrated Hydra capsule-hohlraum calculations coupled to a separate model for calculating the crossbeam energy transfer between the inner and outer cones of the National Ignition Facility (NIF) indirect drive configuration. The time- dependent crossbeam transfer model parameters were adjusted in order to best match the P2 component of the shape of the inflight shell inferred from backlit radiographs of the capsule taken when the shell was at a radius of 150-250 μm. The adjusted model correctly predicts the observed inflight P2 and P4 components of the shape of the inflight shell, and also the P2 component of the shape of the hotspot inferred from x-ray self-emission images at the time of peak emission. It also correctly captures the scaling of the inflight P4 as the hohlraum length is varied. We then applied the newly benchmarked model to quantify the improved symmetry of the N130331 layered deuterium- tritium (DT) experiment in a re-optimized longer hohlraum.
Ara, Perzila; Cheng, Shaokoon; Heimlich, Michael; Dutkiewicz, Eryk
2015-01-01
Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.
Lithographic Printing Via Two-Photon Polymerization of Engineered Foams
Herman, Matthew J.; Peterson, Dominic; Henderson, Kevin; ...
2017-11-29
Understanding deuterium-tritium mix in capsules is critical to achieving fusion within inertial confined fusion experiments. One method of understanding how the mix of hydrogen fuels can be controlled is by creating various structured deuterated foams and filling the capsule with liquid tritium. Historically, these materials have been a stochastically structured gas-blown foam. Later, to improve the uniformity of this material, pore formers have been used which are then chemically removed, leaving behind a foam of monodisperse voids. However, this technique is still imperfect in that fragments of the pore templating particles may not be completely removed and the void distributionmore » may not be uniform over the size scale of the capsule. Recently, advances in three-dimensional printing suggest that it can be used to create microlattices and capsule walls in one single print. Demonstrated in this paper are proof-of-concept microlattices produced using two-photon polymerization with submicrometer resolution of various structures as well as a microlattice-containing capsule. Finally, with this technology, complete control of the mixing structure is possible, amenable to modeling and easily modified for tailored target design.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, Matthew J.; Peterson, Dominic; Henderson, Kevin
Understanding deuterium-tritium mix in capsules is critical to achieving fusion within inertial confined fusion experiments. One method of understanding how the mix of hydrogen fuels can be controlled is by creating various structured deuterated foams and filling the capsule with liquid tritium. Historically, these materials have been a stochastically structured gas-blown foam. Later, to improve the uniformity of this material, pore formers have been used which are then chemically removed, leaving behind a foam of monodisperse voids. However, this technique is still imperfect in that fragments of the pore templating particles may not be completely removed and the void distributionmore » may not be uniform over the size scale of the capsule. Recently, advances in three-dimensional printing suggest that it can be used to create microlattices and capsule walls in one single print. Demonstrated in this paper are proof-of-concept microlattices produced using two-photon polymerization with submicrometer resolution of various structures as well as a microlattice-containing capsule. Finally, with this technology, complete control of the mixing structure is possible, amenable to modeling and easily modified for tailored target design.« less
Demonstration of high coupling efficiency to Al capsule in rugby hohlraum on NIF
NASA Astrophysics Data System (ADS)
Ping, Y.; Smalyuk, V.; Amendt, P.; Bennett, D.; Chen, H.; Dewald, E.; Goyon, C.; Graziani, F.; Johnson, S.; Khan, S.; Landen, O.; Nikroo, A.; Pino, J.; Ralph, J.; Seugling, R.; Strozzi, D.; Tipton, R.; Tommasini, R.; Wang, M.; Loomis, E.; Merritt, E.; Montgomery, D.
2017-10-01
A new design of the double-shell approach predicts a high coupling efficiency from the hohlraum to the capsule, with 700 kJ in the capsule instead of 200kJ in the conventional low-Z single-shell scheme, improving prospects of double-shell performance. A recent experiment on NIF has evaluated a first step toward this goal of energy coupling using 0.7x subscale Al capsule, Au rugby hohlraum and 1MJ drive. A shell velocity of 150 μm/ns was measured, DANTE peak temperature of 255 eV was measured, and shell kinetic energy of 36 kJ was inferred using a rocket model, all close to predictions and consistent with 330kJ of total energy coupled to the capsule. Data analysis and more results from subsequent experiments will be presented. In the next step, an additional 2x increase of total coupled energy up to 700 kJ is projected for full-scale 2-MJ drive in U Rugby hohlraum. This work was performed under DOE contract DE-AC52-07NA27344.
Video capsule endoscopy: Perspectives of a revolutionary technique
Bouchard, Simon; Ibrahim, Mostafa; Van Gossum, Andre
2014-01-01
Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities. PMID:25516644
Ultrasonic technique for inspection of GPHS capsule girth weld integrity
NASA Astrophysics Data System (ADS)
Placr, Arnost
1993-05-01
An innovative nondestructive examination (NDE) technique for the inspection of integrity of General Purpose Heat Source (GPHS) capsule girth welds was developed employing a Lamb wave as the mode of the sound propagation. Reliability of the Lamb wave technique was tested on GPHS capsules using plutonium pallet simulators. All ten capsules, which were previously rejected, passed ultrasonic (UT) inspection using the Lamb wave technique.
Development of three-layered rumen escapable capsules for cattle
SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji
2016-01-01
A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371
Engineering fluorescent poly(dopamine) capsules.
Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank
2014-03-18
The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, Neal G.; Vu, M.; Kong, C.
Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less
Sami, Haider; Maparu, Auhin K; Kumar, Ashok; Sivakumar, Sri
2012-01-01
Towards the goal of development of a generic nanomaterial delivery system and delivery of the 'as prepared' nanoparticles without 'further surface modification' in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb(3+) was observed after internalization of LaF(3):Tb(3+)(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification.
Sami, Haider; Maparu, Auhin K.; Kumar, Ashok; Sivakumar, Sri
2012-01-01
Towards the goal of development of a generic nanomaterial delivery system and delivery of the ‘as prepared’ nanoparticles without ‘further surface modification’ in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb3+ was observed after internalization of LaF3:Tb3+(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification. PMID:22649489
Hugoniot equation of state of Si-doped glow discharge polymer and scaling to other plastic ablators
NASA Astrophysics Data System (ADS)
Huser, G.; Ozaki, N.; Colin-Lalu, P.; Recoules, V.; Sano, T.; Sakawa, Y.; Miyanishi, K.; Kodama, R.
2018-05-01
Pressure, density, and temperature were measured along the principal Hugoniot of the Si-doped Glow Discharge Polymer used in Inertial Confinement Fusion (ICF) capsules up to 5 Mbar, covering conditions beyond the first shock in a full-scale Inertial Confinement Fusion (ICF) capsule. The experiments were performed using the GEKKOXII laser at the Institute of Laser Engineering at Osaka University in Japan. Results are in good agreement with predictions obtained from ab initio Hugoniot calculations, but softer than the quotidian equation of state average atom model. Ab initio calculations show that dissociation of carbon bonds need to be taken into account in order to explain Hugoniot compressibility.
Lee, Yeojin; Kim, Jaejin; Lee, Sanguk; Woo, Young-Ah; Chung, Hoeil
2012-01-30
Direct transmission Raman measurements for analysis of pharmaceuticals in capsules are advantageous since they can be used to determine active pharmaceutical ingredient (API) concentrations in a non-destructive manner and with much less fluorescence background interference from the capsules themselves compared to conventional back-scattering measurements. If a single calibration model such as developed from spectra simply collected in glass vials could be used to determine API concentrations of samples contained in capsules of different colors rather than constructing individual models for each capsule color, the utility of transmission measurements would be further enhanced. To evaluate the feasibility, transmission Raman spectra of binary mixtures of ambroxol and lactose were collected in a glass vial and a partial least squares (PLS) model for the determination of ambroxol concentration was developed. Then, the model was directly applied to determine ambroxol concentrations of samples contained in capsules of 4 different colors (blue, green, white and yellow). Although the prediction performance was slightly degraded when the samples were placed in blue or green capsules, due to the presence of weak fluorescence, accurate determination of ambroxol was generally achieved in all cases. The prediction accuracy was also investigated when the thickness of the capsule was varied. Copyright © 2011 Elsevier B.V. All rights reserved.
Assessing the potential of the Woman's Condom for vaginal drug delivery.
Kramzer, Lindsay F; Cohen, Jessica; Schubert, Jesse; Dezzutti, Charlene S; Moncla, Bernard J; Friend, David; Rohan, Lisa C
2015-09-01
The Woman's Condom is a new female condom that uses a dissolvable polyvinyl alcohol capsule to simplify vaginal insertion. This preclinical study assessed the feasibility to incorporate an antiviral drug, UC781, into the Woman's Condom capsule, offering a unique drug delivery platform. UC781 capsules were fabricated using methods from the development of the Woman's Condom capsules as well as those used in vaginal film development. Capsules were characterized to evaluate physical/chemical attributes, Lactobacillus compatibility, in vitro safety and bioactivity, and condom compatibility. Two UC781 capsule platforms were assessed. Capsule masses (mg; mean±SD) for platforms 1 and 2 were 116.50±18.22 and 93.80±8.49, respectively. Thicknesses were 0.0034±0.0004 in and 0.0033±0.0004 in. Disintegration times were 11±3 s and 5±1 s. Puncture strengths were 21.72±3.30 N and 4.02±0.83 N. Water content measured 6.98±1.17% and 7.04±1.92%. UC781 content was 0.59±0.05 mg and 0.77±0.11 mg. Both platforms retained in vitro bioactivity and were nontoxic to TZM-bl cells and Lactobacillus. Short-term storage of UC781 capsules with the Woman's Condom pouch did not decrease condom mechanical integrity. UC781 was loaded into a polymeric capsule similar to that of the Woman's Condom product. This study highlights the potential use of the Woman's Condom as a platform for vaginal delivery of drugs relevant to sexual/reproductive health, including those for short- or long-acting HIV prevention. We determined the proof-of-concept feasibility of incorporation of an HIV-preventative microbicide into the Woman's Condom capsule. This study highlights various in vitro physical and chemical evaluations as well as bioactivity and safety assessments necessary for vaginal product development related to female sexual and reproductive health. Copyright © 2015 Elsevier Inc. All rights reserved.
Ali, Muthana; McCoy, Thomas M; McKinnon, Ian R; Majumder, Mainak; Tabor, Rico F
2017-05-31
Graphene oxide/polystyrene (GO/PS) nanocomposite capsules containing a two-compartment cargo have been successfully fabricated using a Pickering emulsion strategy. Highly purified GO sheets with typically micrometer-scale lateral dimensions and amphiphilic characteristics were prepared from the oxidation reaction of graphite with concomitant exfoliation of the graphite structure. These GO sheets were employed as a stabilizer for oil-in-water emulsions where the oil phase comprised toluene or olive oil. The stability and morphology of the emulsions were extensively studied as a function of different parameters including GO concentration, aqueous phase pH, ultrasonication time, effects of added electrolytes and stability to dilution. In selected conditions, the olive oil emulsions showed spontaneous formation of multiple w/o/w emulsions with high stability, whereas toluene formed simple o/w emulsions of lower overall stability. Olive oil emulsions were therefore used to prepare capsules templated from emulsion droplets by surrounding the oil phase with a GO/PS shell. The GO sheets, emulsions and composite capsules were characterized using a variety of physical and spectroscopic techniques in order to unravel the interactions responsible for capsule formation. The ability of the capsules to control the release of a model active agent in the form of a hydrophilic dye was explored, and release kinetics were monitored using UV-visible spectroscopy to obtain rate parameters. The composite capsules showed promising sustained release properties, with release rates 11× lower than the precursor GO-stabilized multiple emulsion droplets.
Mercury Capsule Construction at the NASA Lewis Research Center
1959-08-21
A NASA mechanic secures the afterbody to a Mercury capsule in the hangar at the Lewis Research Center. The capsule was one of two built at Lewis for the “Big Joe” launches scheduled for September 1959. The initial phase of Project Mercury consisted of a series of unmanned launches using the Air Force’s Redstone and Atlas boosters and the Langley-designed Little Joe boosters. The first Atlas launch, referred to as “Big Joe”, was a single attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The overall design of Big Joe had been completed by December 1958, and soon thereafter project manager Aleck Bond assigned NASA Lewis the task of designing the electronic instrumentation and automatic stabilization system. Lewis also constructed the capsule’s lower section, which contained a pressurized area with the electronics and two nitrogen tanks for the retrorockets. Lewis technicians were responsible for assembling the entire capsule: the General Electric heatshield, NASA Langley afterbody and recovery canister, and Lewis electronics and control systems. On June 9, 1959, the capsule was loaded on an air force transport aircraft and flown to Cape Canaveral. A team of 45 test operations personnel from Lewis followed the capsule to Florida and spent the ensuing months preparing it for launch. The launch took place in the early morning hours of September 9, 1959.
Capsule implosion optimization during the indirect-drive National Ignition Campaign
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landen, O. L.; Edwards, J.; Haan, S. W.
2011-05-15
Capsule performance optimization campaigns will be conducted at the National Ignition Facility [G. H. Miller, E. I. Moses, and C. R. Wuest, Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition. The campaigns will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models using a variety of ignition capsule surrogates before proceeding to cryogenic-layered implosions and ignition experiments. The quantitative goals and technique options and down selections for the tuning campaigns are first explained. The computationally derived sensitivities to key laser and target parameters are compared to simple analyticmore » models to gain further insight into the physics of the tuning techniques. The results of the validation of the tuning techniques at the OMEGA facility [J. M. Soures et al., Phys. Plasmas 3, 2108 (1996)] under scaled hohlraum and capsule conditions relevant to the ignition design are shown to meet the required sensitivity and accuracy. A roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget. Finally, we show how the tuning precision will be improved after a number of shots and iterations to meet an acceptable level of residual uncertainty.« less
Balcı, Nilay Comuk; Yuruk, Zeliha Ozlem; Zeybek, Aslican; Gulsen, Mustafa; Tekindal, Mustafa Agah
2016-01-01
[Purpose] The aim of our study was to compare the initial effects of scapular proprioceptive neuromuscular facilitation techniques and classic exercise interventions with physiotherapy modalities on pain, scapular dyskinesis, range of motion, and function in adhesive capsulitis. [Subjects and Methods] Fifty-three subjects were allocated to 3 groups: scapular proprioceptive neuromuscular facilitation exercies and physiotherapy modalities, classic exercise and physiotherapy modalities, and only physiotherapy modalities. The intervention was applied in a single session. The Visual Analog Scale, Lateral Scapular Slide Test, range of motion and Simple Shoulder Test were evaluated before and just after the one-hour intervention in the same session (all in one session). [Results] All of the groups showed significant differences in shoulder flexion and abduction range of motion and Simple Shoulder Test scores. There were statistically significant differences in Visual Analog Scale scores in the proprioceptive neuromuscular facilitation and control groups, and no treatment method had significant effect on the Lateral Scapular Slide Test results. There were no statistically significant differences between the groups before and after the intervention. [Conclusion] Proprioceptive neuromuscular facilitation, classic exercise, and physiotherapy modalities had immediate effects on adhesive capsulitis in our study. However, there was no additional benefit of exercises in one session over physiotherapy modalities. Also, an effective treatment regimen for shoulder rehabilitation of adhesive capsulitis patients should include scapular exercises. PMID:27190456
3D Printed Programmable Release Capsules.
Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C
2015-08-12
The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients.
SITE TECHNOLOGY CAPSULE: SONOTECH PULSE COMBUSTION SYSTEM
Sonotech has targeted waste incineration as a potential application for this technology. Based on bench-scale rotary-kiln simulator tests, Sonotech proposed a demonstration under the SITE program to evaluate the Sonotech pulse combustion system on a larger scale at EPA's IRF in J...
Schiele, Julia T; Penner, Heike; Schneider, Hendrik; Quinzler, Renate; Reich, Gabriele; Wezler, Nikolai; Micol, William; Oster, Peter; Haefeli, Walter E
2015-10-01
We evaluated the prevalence of difficulties swallowing solid dosage forms in patients with stroke-induced dysphagia and whether swallowing tablets/capsules increases their risk of penetration and aspiration. Concurrently, we explored whether routinely performed assessment tests help identify patients at risk. Using video endoscopy, we evaluated how 52 patients swallowed four different placebos (round, oval, and oblong tablets and a capsule) with texture-modified water (TMW, pudding consistency) and milk and rated their swallowing performance according to the Penetration Aspiration Scale (PAS). Additionally, Daniels Test, Bogenhausener Dysphagiescore, Scandinavian Stroke Scale, Barthel Index, and Tinetti's Mobility Test were conducted. A substantial proportion of the patients experienced severe difficulties swallowing solid oral dosage forms (TMW: 40.4 %, milk: 43.5 %). Compared to the administration of TMW/milk alone, the placebos increased the PAS values in the majority of the patients (TMW: median PAS from 1.5 to 2.0; milk: median PAS from 1.5 to 2.5, each p value <0.0001) and residue values were significantly higher (p < 0.05). Whereas video-endoscopic examination reliably identified patients with difficulties swallowing medication, neither patients' self-evaluation nor one of the routinely performed bedside tests did. Therefore, before video-endoscopic evaluation, many drugs were modified unnecessarily and 20.8 % of these were crushed inadequately, although switching to another dosage form or drug would have been possible. Hence, safety and effectiveness of swallowing tablets and capsules should be evaluated routinely in video-endoscopic examinations, tablets/capsules should rather be provided with TMW than with milk, and the appropriateness of "non per os except medication" orders for dysphagic stroke patients should be questioned.
Lee, Chi-Hoon; Kaang, Bong-Kiun; Lee, Young-Don
2014-01-01
This study was investigated spawning behavior, structure of egg masses and egg development in Aplysia kurodai inhabiting the coastal waters of Jeju Island, Korea. The mating and courtship behavior of A. kurodai occurred in the form of unilateral copulating with chain formation. In chain copulation, only the first animal acted as a female; the second and succeeding animals acted as males (sperm donors) to the animals in front and as females to the animals behind. The fertilized eggs were packaged in capsules that are embedded in jelly to form a cylindrical string called an egg masses. The number of capsule per cm of the egg masses was 55 to 60 capsules and each capsule within the egg masses held 15 to 25 eggs. After spawning, the egg masses were bright yellow or orange in color. This egg masses color not changed until embryos developed into trochophore stage. Thereafter, as embryo developed from trochophore stage to veliger stage the egg masses color became brownish. The fertilized eggs were spherical, with a diameter of approximately 80±1 μm at spawning. At 5 to 6 days after spawning, the embryo developed into trochophore stage and began to rotate within the egg capsule. In the trochophore stage, the precursor of the velum, called the prototroch or prevelum, developed. At 10 days after spawning, the prevelum is transformed into the velum, and the trochophore developed into veliger stage. Between 10 to 15 days after spawning, the veligers broke out of the egg capsule, and hatched as free-swimming larvae. PMID:25949168
Multishell encapsulation using a triple coaxial electrospray system.
Kim, Woojin; Kim, Sang Soo
2010-06-01
To overcome the limitations of the conventional encapsulation methods and improve the potential use of the electrospray method as a drug delivery system, an electrospray system using a triple coaxial nozzle was developed to generate multishell capsules. Two conducting fluids, ethylene glycol and 4-hydroxybutyl acrylate, and one nonconducting fluid, olive oil, were chosen to manufacture the multishell capsules. The capsules were solidified by a photopolymerization device. We investigated the size distributions and visualized the capsules changing fluid flow rates. Dispersive Raman spectra were also monitored to determine the chemical composition of the capsules. The multishell capsules were generated in the overlapped cone-jet mode regime of the conducting fluids, and the sizes and shell thicknesses were controlled by the flow rates and applied voltages.
Using micro-3D printing to build acoustically driven microswimmers.
NASA Astrophysics Data System (ADS)
Bertin, Nicolas; Stephan, Olivier; Marmottant, Philippe; Spelman, Tamsin; Lauga, Eric; Dyfcom Team; Complex; Biological Fluids Team
2015-11-01
With no protection, a micron-sized free air bubble at room temperature in water has a life span shorter than a few tens of seconds. Using two-photon lithography, which is similar to 3D printing at the micron scale, we can build ``armors'' for these bubbles: micro-capsules with an opening to contain the bubble and extend its life to several hours in biological buffer solutions. When excited by an ultrasound transducer, a 20 μm bubble performs large amplitude oscillations in the capsule opening and generates a powerful acoustic streaming flow (velocity up to dozens of mm/s). A collaboration with the Dept. of Applied Mathematics and Theoretical Physics, University of Cambridge, is helping us predict the true resonance of these capsules and the full surrounding streaming flow. The present Bubbleboost project aims at creating red blood cell sized capsules (~ 10-20 μm) that can move on their own with a non-contact acoustic excitation for drug delivery applications. Another application of this research is in microfluidics: we are able to fabricate fields of capsules able to generate mixing effects in microchannels, or use the bubble-generated flow to guide passing objects at a junction. ERC Grant Agreement Bubbleboost no. 614655.
Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules
NASA Astrophysics Data System (ADS)
Hayes, A. C.; Bradley, P. A.; Grim, G. P.; Jungman, Gerard; Wilhelmy, J. B.
2010-01-01
Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIF production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.
Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M
2008-01-01
Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278
NASA Astrophysics Data System (ADS)
Andrade-Villagrán, P. V.; Baria, K. S.; Montory, J. A.; Pechenik, J. A.; Chaparro, O. R.
2018-01-01
Encapsulated embryos are generally thought to play an active role in escaping from egg capsules or egg masses. However, for species that brood their egg capsules, the factors controlling the timing of hatching are largely unclear, particularly the degree to which hatching is controlled by the embryos rather than by the mother, and the degree to which the hatching of one egg capsule influences the hatching of sister egg capsules within the same egg mass. We studied aspects of hatching using the direct-developing gastropod Crepipatella dilatata, which includes nurse eggs in its egg capsules and broods clusters of egg capsules for at least several weeks before metamorphosed juveniles are released. Isolated egg capsules were able to hatch successfully, in the absence of the mother. Moreover, the hatching of one capsule did not cause adjacent sister capsules to hatch. Hatched and un-hatched sister egg capsules from the same egg mass differed significantly in the number of metamorphosed juveniles, average shell size, offspring biomass (juveniles + veliger larvae), and the number of nurse eggs remaining per egg capsule. Differences in when egg capsules hatched within a single egg mass were not explained by differences in egg capsule age. Hatching occurred only after most nurse eggs had been ingested, most offspring had metamorphosed into juveniles, and juveniles had reached a mean shell length > 1.36 mm. Whether the mother has any role to play in coordinating the hatching process or juvenile release remains to be determined.
Lok, Kris Y W; Chan, Ruth S M; Lee, Vivian W Y; Leung, Patrick W; Leung, Cynthia; Leung, Jason; Woo, Jean
2013-01-01
To test the individual effect of artificial food colorings (AFCs) and a preservative on the behavior of the general Chinese population. One hundred thirty children (70 boys and 60 girls) in Hong Kong with a mean age of 8.64 years were enlisted to the study with a within-subject crossover between AFCs, a preservative (sodium benzoate), and a placebo capsule. Two behavior scores were used including the strengths and weaknesses of attention deficit hyperactivity disorder and normal behavior rating scale and the child behavior checklist-teacher report form. Capsule A containing AFCs and Capsule B containing sodium benzoate had no significant adverse effect compared with placebo in both behavior scores. This result persisted when analysis was restricted to children with 85% consumption of capsule (per protocol analysis). There seem to be no significant associations between AFCs and a preservative on Chinese children's behavior at the age of 8 to 9 years. Future directions and implications of this research are discussed.
Liu, Simin
2008-01-01
High definition self-assemblies, those that possess order at the molecular level, are most commonly made from subunits possessing metals and metal coordination sites, or groups capable of partaking in hydrogen bonding. In other words, enthalpy is the driving force behind the free energy of assembly. The hydrophobic effect engenders the possibility of (nominally) relying not on enthalpy but entropy to drive assembly. Towards this idea, we describe how template molecules can trigger the dimerization of a cavitand in aqueous solution, and in doing so are encapsulated within the resulting capsule. Although not held together by (enthalpically) strong and directional non-covalent forces, these capsules possess considerable thermodynamic and kinetic stability. As a result, they display unusual and even unique properties. We discuss some of these, including the use of the capsule as a nano-scale reaction chamber and how they can bring about the separation of hydrocarbon gases. PMID:18685753
A modular and programmable development platform for capsule endoscopy system.
Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A
2014-06-01
The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.
Capsule endoscopy—A mechatronics perspective
NASA Astrophysics Data System (ADS)
Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay
2011-03-01
The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.
Xiao Jia; Meng, Max Q-H
2017-07-01
Gastrointestinal (GI) bleeding detection plays an essential role in wireless capsule endoscopy (WCE) examination. In this paper, we present a new approach for WCE bleeding detection that combines handcrafted (HC) features and convolutional neural network (CNN) features. Compared with our previous work, a smaller-scale CNN architecture is constructed to lower the computational cost. In experiments, we show that the proposed strategy is highly capable when training data is limited, and yields comparable or better results than the latest methods.
Reisenwitz, T H; Wimbish, G J
1996-01-01
The capsule dosage form in nonprescription pharmaceuticals persists as being one of the most vulnerable to product tampering. This study examines consumer preference toward three solid oral dosage forms (capsules, caplets, and tablets) in nonprescription products. Thirteen independent variables representing dosage form attributes are measured on semantic differential scales. The data are analyzed using analysis of variance (ANOVA) and factor analysis. Implications for the pharmaceutical marketer are noted. Future directions for research are also outlined.
Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick
2004-05-01
To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.
Fukatsu, Takema; Hosokawa, Takahiro
2002-01-01
The Japanese common plataspid stinkbug, Megacopta punctatissima, deposits small brown particles, or symbiont capsules, on the underside of the egg mass for the purpose of transmission of symbiotic bacteria to the offspring. We investigated the microbiological aspects of the bacteria contained in the capsule, such as microbial diversity, phylogenetic placement, localization in vivo, and fitness effects on the host insect. Restriction fragment length polymorphism analysis of 16S ribosomal DNA clones revealed that a single bacterial species dominates the microbiota in the capsule. The bacterium was not detected in the eggs but in the capsules, which unequivocally demonstrated that the bacterium is transmitted to the offspring of the insect orally rather than transovarially, through probing of the capsule content. Molecular phylogenetic analysis showed that the bacterium belongs to the γ-subdivision of the Proteobacteria. In adult insects the bacterium was localized in the posterior section of the midgut. Deprivation of the bacterium from the nymphs resulted in retarded development, arrested growth, abnormal body coloration, and other symptoms, suggesting that the bacterium is essential for normal development and growth of the host insect. PMID:11772649
Anderson, Gregory G; Goller, Carlos C; Justice, Sheryl; Hultgren, Scott J; Seed, Patrick C
2010-03-01
Uropathogenic Escherichia coli (UPEC) is the leading cause of urinary tract infections (UTIs). A murine UTI model has revealed an infection cascade whereby UPEC undergoes cycles of invasion of the bladder epithelium, intracellular proliferation in polysaccharide-containing biofilm-like masses called intracellular bacterial communities (IBC), and then dispersal into the bladder lumen to initiate further rounds of epithelial colonization and invasion. We predicted that the UPEC K1 polysaccharide capsule is a key constituent of the IBC matrix. Compared to prototypic E. coli K1 strain UTI89, a capsule assembly mutant had a fitness defect in functionally TLR4(+) and TLR4(-) mice, suggesting a protective role of capsule in inflamed and noninflamed hosts. K1 capsule assembly and synthesis mutants had dramatically reduced IBC formation, demonstrating the common requirement for K1 polysaccharide in IBC development. The capsule assembly mutant appeared dispersed in the cytoplasm of the bladder epithelial cells and failed to undergo high-density intracellular replication during later stages of infection, when the wild-type strain continued to form serial generations of IBC. Deletion of the sialic acid regulator gene nanR partially restored IBC formation in the capsule assembly mutant. These data suggest that capsule is necessary for efficient IBC formation and that aberrant sialic acid accumulation, resulting from disruption of K1 capsule assembly, produces a NanR-mediated defect in intracellular proliferation and IBC development. Together, these data demonstrate the complex but important roles of UPEC polysaccharide encapsulation and sialic acid signaling in multiple stages of UTI pathogenesis.
Danysh, Brian P.; Duncan, Melinda K.
2009-01-01
The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892
Hydro-scaling of DT implosions on the National Ignition Facility
NASA Astrophysics Data System (ADS)
Patel, Pravesh; Spears, Brian; Clark, Dan
2017-10-01
Recent implosion experiments on the National Ignition Facility (NIF) exceed 50 kJ in fusion yield and exhibit yield amplifications of >2.5-3x due to alpha-particle self-heating of the hot-spot. Two methods to increase the yield are (i) to improve the implosion quality, or stagnation pressure, at fixed target scale (by increasing implosion velocity, reducing 3D effects, etc.), and (ii) to hydrodynamically scale the capsule and absorbed energy. In the latter case the stagnation pressure remains constant, but the yield-in the absence of alpha-heating-increases as Y S 4 . 5 , where the capsule radius is increased by S, and the absorbed energy by S3 . With alpha-heating the increase with scale is considerably stronger. We present projections in the performance of current DT experiments, and the extrapolations to ignition, based on applying hydro-scaling theory and accounting for the effect of alpha-heating. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randolph, Randall Blaine; Oertel, John A.; Schmidt, Derek William
For this study, machined CH hemi-shell ablator capsules have been successfully produced by the MST-7 Target Fabrication Team at Los Alamos National Laboratory. Process development and micro-machining techniques have been developed to produce capsules for both the Omega and National Ignition Facility (NIF) campaigns. These capsules are gas filled up to 10 atm and consist of a machined plastic hemi-shell outer layer that accommodates various specially engineered low-density polystyrene foam cores. Machining and assembly of the two-part, step-jointed plastic hemi-shell outer layer required development of new techniques, processes, and tooling while still meeting very aggressive shot schedules for both campaigns.more » Finally, problems encountered and process improvements will be discussed that describe this very unique, complex capsule design approach through the first Omega proof-of-concept version to the larger NIF version.« less
Light weight escape capsule for fighter aircraft
NASA Technical Reports Server (NTRS)
Robert, James A.
1988-01-01
Emergency crew escape capabilities have been less than adequate for fighter aircraft since before WW II. From the over-the-side bailout of those days through the current ejection seat with a rocket catapult, escaping from a disabled aircraft has been risky at best. Current efforts are underway toward developing a high-tech, smart ejection seat that will give fighter pilots more room to live in the sky, but an escape capsule is needed to meet current and future fighter envelopes. Escape capsules have a bad reputation due to past examples of high weight, poor performance and great complexity. However, the advantages available demand that a capsule be developed. This capsule concept will minimize the inherent disavantages and incorporate the benefits while integrating all aspects of crew station design. The resulting design is appropriate for a crew station of the year 2010 and includes improved combat acceleration protection, chemical or biological combat capability, improved aircraft to escape system interaction, and the highest level of escape performance achievable. The capsule is compact, which can allow a reduced aircraft size and weighs only 1200 lb. The escape system weight penalty is only 120 lb higher than that for the next ejection seat and the capsule has a corresponding increase in performance.
1982-02-01
control unit will detect and classify submerged submarins transiting within PJ The EnCAPsulated pedo augments air, surface and submarine anti...vidicon (date link video enhancement). Conduct Operational Test and Evaluation. Complete Large Scale Integration Receiver-Decoder improvement. Continue...analysis, and data link video enhancement focusing on application of a new silicon vidicon was continued; data link improvements such as adaptive null
Antioxidant functionalized polymer capsules to prevent oxidative stress.
Larrañaga, Aitor; Isa, Isma Liza Mohd; Patil, Vaibhav; Thamboo, Sagana; Lomora, Mihai; Fernández-Yague, Marc A; Sarasua, Jose-Ramon; Palivan, Cornelia G; Pandit, Abhay
2018-02-01
Polymeric capsules exhibit significant potential for therapeutic applications as microreactors, where the bio-chemical reactions of interest are efficiently performed in a spatial and time defined manner due to the encapsulation of an active biomolecule (e.g., enzyme) and control over the transfer of reagents and products through the capsular membrane. In this work, catalase loaded polymer capsules functionalized with an external layer of tannic acid (TA) are fabricated via a layer-by-layer approach using calcium carbonate as a sacrificial template. The capsules functionalised with TA exhibit a higher scavenging capacity for hydrogen peroxide and hydroxyl radicals, suggesting that the external layer of TA shows intrinsic antioxidant properties, and represents a valid strategy to increase the overall antioxidant potential of the developed capsules. Additionally, the hydrogen peroxide scavenging capacity of the capsules is enhanced in the presence of the encapsulated catalase. The capsules prevent oxidative stress in an in vitro inflammation model of degenerative disc disease. Moreover, the expression of matrix metalloproteinase-3 (MMP-3), and disintegrin and metalloproteinase with thrombospondin motif-5 (ADAMTS-5), which represents the major proteolytic enzymes in intervertebral disc, are attenuated in the presence of the polymer capsules. This platform technology exhibits potential to reduce oxidative stress, a key modulator in the pathology of a broad range of inflammatory diseases. Oxidative stress damages important cell structures leading to cellular apoptosis and senescence, for numerous disease pathologies including cancer, neurodegeneration or osteoarthritis. Thus, the development of biomaterials-based systems to control oxidative stress has gained an increasing interest. Herein, polymer capsules loaded with catalase and functionalized with an external layer of tannic acid are fabricated, which can efficiently scavenge important reactive oxygen species (i.e., hydroxyl radicals and hydrogen peroxide) and modulate extracellular matrix activity in an in vitro inflammation model of nucleus pulposus. The present work represents accordingly, an important advance in the development and application of polymer capsules with antioxidant properties for the treatment of oxidative stress, which is applicable for multiple inflammatory disease targets. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields
NASA Astrophysics Data System (ADS)
Wischnewski, Christian; Kierfeld, Jan
2018-04-01
We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.
Hooks, S Bennett; Rutland, Travis J; Di Palma, Jack A
2009-11-01
Lubiprostone, a selective activator of type 2 chloride channels, is approved for treatment of chronic idiopathic constipation and recently constipation-predominant irritable bowel syndrome. It has been suggested that lubiprostone has a prokinetic effect. This investigation was designed to evaluate lubiprostone as a preparation and propulsive agent for small-bowel capsule endoscopy. The PillCam Small Bowel capsule endoscopy system with the PillCam SB1 capsule and Rapid 5 software platform were used. The study was designed as a double-blind, placebo-controlled trial. Forty healthy adults. Gastric transit time (GTT), small-bowel transit time (SBTT), and adequacy of small-bowel cleansing preparation. The study subjects received 24 mug lubiprostone or placebo 30 minutes before PillCam capsule ingestion. Capsule endoscopy studies were read by 2 independent investigators unaware of the study medication received, and differences in interpretation were resolved by consensus. Anatomical landmarks were identified, and GTT and SBTT were calculated. Overall preparation quality assessment of the proximal, mid, and distal small bowel was determined by using a 4-step scale. The percentage of visualized bowel was determined by review of 10-minute video segments at 1-hour intervals after the capsule passed through the pylorus. In the lubiprostone group (n = 20), 2 subjects did not pass the capsule through the pylorus in the 8-hour battery life of the capsule. An additional 3 capsules did not pass into the colon. In the placebo group (n = 20), all capsules passed into the small bowel, but 1 did not pass into the colon. The subjects in whom the capsule did not pass into the small bowel were excluded from the small-bowel analysis. In the subjects in whom the capsule did reach the colon, the SBTT could not be calculated and they were excluded from SBTT analysis. The mean GTT in the lubiprostone group was 126 minutes and 43 minutes in the placebo group (P = .0095). The mean SBTT in the lubiprostone group was 188 minutes and 219 minutes in the placebo group (P = .130). The overall preparation assessment of the small bowel was not statistically significant between the 2 groups in the proximal, mid, or distal small bowel (proximal, P = .119; mid, P = .118; distal, P = .121). There was no significant difference in lubiprostone compared with placebo in the percentage of visualized small bowel. Some capsules did not leave the stomach or reach the cecum. Lubiprostone produced a significant increase in GTT but did not result in a significant decrease in SBTT compared with placebo. The administration of lubiprostone before capsule ingestion did not result in improved overall preparation of the small bowel for capsule endoscopy or increase the percentage of visualized small bowel. (The trial was registered at www.clinicaltrials.gov, identifier NCT00746395.).
Absorption and subjective effects of caffeine from coffee, cola and capsules.
Liguori, A; Hughes, J R; Grass, J A
1997-11-01
Coffee is often perceived as producing greater pharmacological effects than cola. The present study compared the magnitude and rapidity of peak caffeine levels and subjective effects between coffee and cola. Thirteen users of both coffee and cola (mean daily caffeine consumption = 456 mg) ingested 400 mg caffeine via 12 oz unsweetened coffee, 24 oz sugar-free cola or 2 capsules in a random, double-blind, placebo-controlled, within-subjects design. Subjects provided a saliva sample and completed subjective effect scales 15 min before and 30, 60, 90, 120, 180 and 240 min after ingestion. Mean peak saliva caffeine levels did not differ between coffee (9.7 +/- 1.2 micrograms/ml) and cola (9.8 +/- 0.9 micrograms/ml) and appeared to be greater with these beverages than with the capsule (7.8 +/- 0.6 micrograms/ml; p = NS). Saliva caffeine levels peaked at similar times for coffee (42 +/- 5 min) and cola (39 +/- 5 min) but later for capsule (67 +/- 7 min; p = 0.004). There was no main effect of vehicle or interaction of vehicle and drug on magnitude of peak effect or time to peak increase on self-report scales. In summary, peak caffeine absorption, time to peak absorption, and subjective effects do not appear to be influenced by cola vs. coffee vehicle. Perceived differences in the effects of coffee vs. cola may be due to differences in dose, time of day, added sweetener, environmental setting or contingencies.
Mitter, Christian; Jakab, András; Brugger, Peter C.; Ricken, Gerda; Gruber, Gerlinde M.; Bettelheim, Dieter; Scharrer, Anke; Langs, Georg; Hainfellner, Johannes A.; Prayer, Daniela; Kasprian, Gregor
2015-01-01
Diffusion tensor imaging (DTI) and tractography offer the unique possibility to visualize the developing white matter macroanatomy of the human fetal brain in vivo and in utero and are currently under investigation for their potential use in the diagnosis of developmental pathologies of the human central nervous system. However, in order to establish in utero DTI as a clinical imaging tool, an independent comparison between macroscopic imaging and microscopic histology data in the same subject is needed. The present study aimed to cross-validate normal as well as abnormal in utero tractography results of commissural and internal capsule fibers in human fetal brains using postmortem histological structure tensor (ST) analysis. In utero tractography findings from two structurally unremarkable and five abnormal fetal brains were compared to the results of postmortem ST analysis applied to digitalized whole hemisphere sections of the same subjects. An approach to perform ST-based deterministic tractography in histological sections was implemented to overcome limitations in correlating in utero tractography to postmortem histology data. ST analysis and histology-based tractography of fetal brain sections enabled the direct assessment of the anisotropic organization and main fiber orientation of fetal telencephalic layers on a micro- and macroscopic scale, and validated in utero tractography results of corpus callosum and internal capsule fiber tracts. Cross-validation of abnormal in utero tractography results could be achieved in four subjects with agenesis of the corpus callosum (ACC) and in two cases with malformations of internal capsule fibers. In addition, potential limitations of current DTI-based in utero tractography could be demonstrated in several brain regions. Combining the three-dimensional nature of DTI-based in utero tractography with the microscopic resolution provided by histological ST analysis may ultimately facilitate a more complete morphologic characterization of axon guidance disorders at prenatal stages of human brain development. PMID:26732460
DOT National Transportation Integrated Search
2008-12-01
PROBLEM: The full-scale accelerated pavement testing (APT) provides a unique tool for pavement : engineers to directly collect pavement performance and failure data under heavy : wheel loading. However, running a full-scale APT experiment is very exp...
Malakar, Jadupati; Datta, Prabir Kumar; Purakayastha, Saikat Das; Dey, Sanjay; Nayak, Amit Kumar
2014-03-01
The present study deals with the development and evaluations of stomach-specific floating capsules containing salbutamol sulfate-loaded oil-entrapped alginate-based beads. Salbutamol sulfate-loaded oil-entrapped beads were prepared and capsulated within hard gelatin capsules (size 1). The effects of HPMC K4M and potato starch weight masses on drug encapsulation efficiency (DEE) of beads and cumulative drug release at 10h (R10 h) from capsules was analyzed by 3(2) factorial design. The optimization results indicate increasing of DEE in the oil-entrapped beads and decreasing R10 h from capsules with increment of HPMC K4M and potato starch weight masses. The optimized formulation showed DEE of 70.02 ± 3.16% and R10 h of 56.96 ± 2.92%. These capsules showed floatation over 6h and sustained drug release over 10h in gastric pH (1.2). In vivo X-ray imaging study of optimized floating capsules in rabbits showed stomach-specific gastroretention over a prolonged period. Copyright © 2013 Elsevier B.V. All rights reserved.
Assessing the potential of the Woman's Condom for vaginal drug delivery
Kramzer, Lindsay F.; Cohen, Jessica; Schubert, Jesse; Dezzutti, Charlene S.; Moncla, Bernard J.; Friend, David; Rohan, Lisa C.
2015-01-01
Background The Woman's Condom is a new female condom that uses a dissolvable polyvinyl alcohol (PVA) capsule to simplify vaginal insertion. This preclinical study assessed the feasibility to incorporate an antiviral drug, UC781, into the Woman's Condom capsule, offering a unique drug delivery platform. Study Design UC781 capsules were fabricated using methods from the development of the Woman's Condom capsules as well as those used in vaginal film development. Capsules were characterized to evaluate physical/chemical attributes, Lactobacillus compatibility, in vitro safety and bioactivity, and condom compatibility. Results Two UC781 capsule platforms were assessed. Capsule masses (mg; mean ± SD) for platforms 1 and 2 were 116.50 ± 18.22 and 93.80 ± 8.49, respectively. Thicknesses were 0.0034 ± 0.0004 in and 0.0033 ± 0.0004 in. Disintegration times were 11 ± 3 sec and 5 ± 1 sec. Puncture strengths were 21.72 ± 3.30 N and 4.02 ± 0.83 N. Water content measured 6.98 ± 1.17 % and 7.04 ± 1.92 %. UC781 content was 0.59 ± 0.05 mg and 0.77 ± 0.11 mg. Both platforms retained in vitro bioactivity and were non-toxic to TZM-bl cells and Lactobacillus. Short-term storage of UC781 capsules with the Woman's Condom pouch did not decrease condom mechanical integrity. Conclusions UC781 was loaded into a polymeric capsule similar to that of the Woman's Condom product. This study highlights the potential use of the Woman's Condom as a platform for vaginal delivery of drugs relevant to sexual/reproductive health, including those for short or long-acting HIV prevention. PMID:25998936
Fabrication of capsule assemblies, phase 3
NASA Technical Reports Server (NTRS)
Keeton, A. R.; Stemann, L. G.
1973-01-01
Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.
Aerodynamics of electrically driven freight pipeline system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundgren, T.S.; Zhao, Y.
2000-06-01
This paper examines the aerodynamic characteristics of a freight pipeline system in which freight capsules are individually propelled by electrical motors. The fundamental difference between this system and the more extensively studied pneumatic capsule pipeline is the different role played by aerodynamic forces. In a driven system the propelled capsules are resisted by aerodynamic forces and, in reaction, pump air through the tube. In contrast, in a pneumatically propelled system external blowers pump air through the tubes, and this provides the thrust for the capsules. An incompressible transient analysis is developed to study the aerodynamics of multiple capsules in amore » cross-linked two-bore pipeline. An aerodynamic friction coefficient is used as a cost parameter to compare the effects of capsule blockage and headway and to assess the merits of adits and vents. The authors conclude that optimum efficiency for off-design operation is obtained with long platoons of capsules in vented or adit connected tubes.« less
Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N
2008-05-01
Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-09-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-01-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839
Scaling effects in spiral capsule robots.
Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan
2017-04-01
Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2 m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.
Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, A. C.; Bradley, P. A.; Grim, G. P.
2010-01-15
Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIFmore » production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.« less
Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi
2014-01-01
The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.
Role of capsule endoscopy in inflammatory bowel disease.
Kopylov, Uri; Seidman, Ernest G
2014-02-07
Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.
Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung
2012-07-01
This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.
Inertial confinement fusion ablator physics experiments on Saturn and Nova
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, R.E.; Porter, J.L.; Chandler, G.A.
1997-05-01
The Saturn pulsed power accelerator [R. B. Spielman {ital et al.}, in {ital Proceedings of the 2nd International Conference on Dense} Z-{ital pinches}, Laguna Beach, CA, 1989, edited by N. R. Pereira, J. Davis, and N. Rostoker (American Institute of Physics, New York, 1989), p. 3] at Sandia National Laboratories (SNL) and the Nova laser [J. T. Hunt and D. R. Speck, Opt. Eng. {bold 28}, 461 (1989)] at Lawrence Livermore National Laboratory (LLNL) have been used to explore techniques for studying the behavior of ablator material in x-ray radiation environments comparable in magnitude, spectrum, and duration to those thatmore » would be experienced in National Ignition Facility (NIF) hohlraums [J. D. Lindl, Phys. Plasmas {bold 2}, 3933 (1995)]. The large x-ray outputs available from the Saturn pulsed-power-driven z pinch have enabled us to drive hohlraums of full NIF ignition scale size at radiation temperatures and time scales comparable to those required for the low-power foot pulse of an ignition capsule. The high-intensity drives available in the Nova laser have allowed us to study capsule ablator physics in smaller-scale hohlraums at radiation temperatures and time scales relevant to the peak power pulse for an ignition capsule. Taken together, these experiments have pointed the way to possible techniques for testing radiation-hydrodynamics code predictions of radiation flow, opacity, equation of state, and ablator shock velocity over the range of radiation environments that will be encountered in a NIF hohlraum. {copyright} {ital 1997 American Institute of Physics.}« less
Bubble-based acoustic swimmers: a dual micro/macro-fluidics study
NASA Astrophysics Data System (ADS)
Bertin, Nicolas; Spelman, Tamsin; StéPhan, Olivier; Lauga, Eric; Marmottant, Philippe
Without protection, a micron-sized free air bubble at room temperature in water has a life duration shorter than a few tens of seconds. Using two-photon lithography, which is similar to 3D printing at the micron scale, we can build ''armors'' for these bubbles: micro-capsules with an opening. These armors contain the bubble and extend its lifespan to several hours in biological buffer solutions. When excited by an external ultrasonic wave, the bubble performs large amplitude oscillations at the capsule opening and generates a powerful acoustic streaming flow (velocity up to dozens of mm/s). We show how to obtain blood-vessel-sized acoustic swimmers for drug-delivery applications. They contain multiple capsules of different aperture sizes: this makes them resonant at different frequencies. By adjusting the frequency, we can adjust the swimming direction. A micro/macro parallel study is also performed. On one hand, we study microswimmers on the 20-50 µm scale: propulsion forces are measured and predicted. On the other hand, we study macroscopic ''milliswimmers'' containing bubbles that are 2 to 10 mm in diameter, allowing us to understand in detail the modes of vibration, to quantitatively predict the swimming motions and inspire new designs for microswimmers.
Traas, Anne M; Fleck, Timothy; Ellings, Andrea; Mahabir, Sean; Stuebner, Kathy; Brown, Dorothy C; Durso, Dana; DiGregorio, Michael; Bode, Lora; Kievit, Kelly I; McCall, Robert
2010-06-01
To compare owner-assessed ease of administration and overall acceptability of 3 chemically inactive formulations administered PO to cats. 90 healthy client-owned cats. Cats were randomly assigned to receive 1 of 3 formulations PO once daily for 14 days: medium chain triglyceride (MCT) oil, dissolving thin film strips (proprietary ingredients), or gelatin capsules filled with microcrystalline cellulose. Owners administered the formulations and rated ease of administration daily on a 10-cm visual analogue scale (VAS). At the end of the study, owners rated overall acceptability of formulations from their own perspective and their overall perception of acceptability to their cat. Mean VAS scores for daily ease of administration of MCT oil and film strips were significantly higher than scores for gelatin capsules at all time points, except on days 2, 4, and 7. There was no difference between MCT oil and film strip formulation scores. Mean VAS scores were 8.8 (MCT oil), 8.9 (film strips), and 7.4 (gelatin capsules) for overall acceptability to owners and 8.0 (MCT oil), 8.3 (film strips), and 6.7 (gelatin capsules) for overall owner-perceived acceptability to cats. Daily ease of administration on 11 of 14 days and overall owner-perceived acceptability to cats were scored significantly higher for film strips and MCT oil, compared with scores for gelatin capsules. Overall acceptability to owners followed a similar pattern; however, the differences were not significant. Dissolving thin film strip or MCT oil vehicles may allow for easier PO administration of medication to cats than does administration of gelatin capsules.
Hu, Chuangang; Xiao, Ying; Zhao, Yang; Chen, Nan; Zhang, Zhipan; Cao, Minhua; Qu, Liangti
2013-04-07
Highly nitrogen-doped carbon capsules (hN-CCs) have been successfully prepared by using inexpensive melamine and glyoxal as precursors via solvothermal reaction and carbonization. With a great promise for large scale production, the hN-CCs, having large surface area and high-level nitrogen content (N/C atomic ration of ca. 13%), possess superior crossover resistance, selective activity and catalytic stability towards oxygen reduction reaction for fuel cells in alkaline medium. As a new anode material in lithium-ion battery, hN-CCs also exhibit excellent cycle performance and high rate capacity with a reversible capacity of as high as 1046 mA h g(-1) at a current density of 50 mA g(-1) after 50 cycles. These features make the hN-CCs developed in this study promising as suitable substitutes for the expensive noble metal catalysts in the next generation alkaline fuel cells, and as advanced electrode materials in lithium-ion batteries.
Spawn in two deep-sea volute gastropods (Neogastropoda: Volutidae) from southwestern Atlantic waters
NASA Astrophysics Data System (ADS)
Penchaszadeh, Pablo E.; Teso, Valeria; Pastorino, Guido
2017-12-01
The gastropods Odontocymbiola pescalia and Provocator corderoi and their egg capsules were collected by the R/V Puerto Deseado from the Mar del Plata Submarine Canyon ( 37°53‧S, at depths of 291-1404 m) and from Burdwood Bank ( 54°27‧S, 128-785 m). Odontocymbiola pescalia egg capsules measured 15.67 ± 3.38 mm in diameter. They were subspherical in shape with an external calcareous layer. Each egg capsule contained 3-5 embryos and white material as extra embryonic food. Embryos grew to a size of up to 9.3 ± 1.1 mm in mean shell length before hatching as crawling juveniles. The spawn of P. corderoi consisted of a single dome shaped egg capsule of 14.17 ± 1.5 mm in diameter, attached to hard substrata by a basal membrane with a rounded outline. A curved semilunar furrow (seam) on one side of the capsules was always present. The number of embryos per capsule was 2-6. Embryos hatched as crawling juveniles with a shell length of 5.9 ± 0.6 mm. The size and number of whorls in the hatchling shell suggested a slow rate of development, akin to many other deep-sea invertebrates. The egg capsules and reproductive development strategies of both species were compared with those from other congeneric representatives.
NASA Astrophysics Data System (ADS)
Glenzer, S. H.; MacGowan, B. J.; Meezan, N. B.; Adams, P. A.; Alfonso, J. B.; Alger, E. T.; Alherz, Z.; Alvarez, L. F.; Alvarez, S. S.; Amick, P. V.; Andersson, K. S.; Andrews, S. D.; Antonini, G. J.; Arnold, P. A.; Atkinson, D. P.; Auyang, L.; Azevedo, S. G.; Balaoing, B. N. M.; Baltz, J. A.; Barbosa, F.; Bardsley, G. W.; Barker, D. A.; Barnes, A. I.; Baron, A.; Beeler, R. G.; Beeman, B. V.; Belk, L. R.; Bell, J. C.; Bell, P. M.; Berger, R. L.; Bergonia, M. A.; Bernardez, L. J.; Berzins, L. V.; Bettenhausen, R. C.; Bezerides, L.; Bhandarkar, S. D.; Bishop, C. L.; Bond, E. J.; Bopp, D. R.; Borgman, J. A.; Bower, J. R.; Bowers, G. A.; Bowers, M. W.; Boyle, D. T.; Bradley, D. K.; Bragg, J. L.; Braucht, J.; Brinkerhoff, D. L.; Browning, D. F.; Brunton, G. K.; Burkhart, S. C.; Burns, S. R.; Burns, K. E.; Burr, B.; Burrows, L. M.; Butlin, R. K.; Cahayag, N. J.; Callahan, D. A.; Cardinale, P. S.; Carey, R. W.; Carlson, J. W.; Casey, A. D.; Castro, C.; Celeste, J. R.; Chakicherla, A. Y.; Chambers, F. W.; Chan, C.; Chandrasekaran, H.; Chang, C.; Chapman, R. F.; Charron, K.; Chen, Y.; Christensen, M. J.; Churby, A. J.; Clancy, T. J.; Cline, B. D.; Clowdus, L. C.; Cocherell, D. G.; Coffield, F. E.; Cohen, S. J.; Costa, R. L.; Cox, J. R.; Curnow, G. M.; Dailey, M. J.; Danforth, P. M.; Darbee, R.; Datte, P. S.; Davis, J. A.; Deis, G. A.; Demaret, R. D.; Dewald, E. L.; di Nicola, P.; di Nicola, J. M.; Divol, L.; Dixit, S.; Dobson, D. B.; Doppner, T.; Driscoll, J. D.; Dugorepec, J.; Duncan, J. J.; Dupuy, P. C.; Dzenitis, E. G.; Eckart, M. J.; Edson, S. L.; Edwards, G. J.; Edwards, M. J.; Edwards, O. D.; Edwards, P. W.; Ellefson, J. C.; Ellerbee, C. H.; Erbert, G. V.; Estes, C. M.; Fabyan, W. J.; Fallejo, R. N.; Fedorov, M.; Felker, B.; Fink, J. T.; Finney, M. D.; Finnie, L. F.; Fischer, M. J.; Fisher, J. M.; Fishler, B. T.; Florio, J. W.; Forsman, A.; Foxworthy, C. B.; Franks, R. M.; Frazier, T.; Frieder, G.; Fung, T.; Gawinski, G. N.; Gibson, C. R.; Giraldez, E.; Glenn, S. M.; Golick, B. P.; Gonzales, H.; Gonzales, S. A.; Gonzalez, M. J.; Griffin, K. L.; Grippen, J.; Gross, S. M.; Gschweng, P. H.; Gururangan, G.; Gu, K.; Haan, S. W.; Hahn, S. R.; Haid, B. J.; Hamblen, J. E.; Hammel, B. A.; Hamza, A. V.; Hardy, D. L.; Hart, D. R.; Hartley, R. G.; Haynam, C. A.; Heestand, G. M.; Hermann, M. R.; Hermes, G. L.; Hey, D. S.; Hibbard, R. L.; Hicks, D. G.; Hinkel, D. E.; Hipple, D. L.; Hitchcock, J. D.; Hodtwalker, D. L.; Holder, J. P.; Hollis, J. D.; Holtmeier, G. M.; Huber, S. R.; Huey, A. W.; Hulsey, D. N.; Hunter, S. L.; Huppler, T. R.; Hutton, M. S.; Izumi, N.; Jackson, J. L.; Jackson, M. A.; Jancaitis, K. S.; Jedlovec, D. R.; Johnson, B.; Johnson, M. C.; Johnson, T.; Johnston, M. P.; Jones, O. S.; Kalantar, D. H.; Kamperschroer, J. H.; Kauffman, R. L.; Keating, G. A.; Kegelmeyer, L. M.; Kenitzer, S. L.; Kimbrough, J. R.; King, K.; Kirkwood, R. K.; Klingmann, J. L.; Knittel, K. M.; Kohut, T. R.; Koka, K. G.; Kramer, S. W.; Krammen, J. E.; Krauter, K. G.; Krauter, G. W.; Krieger, E. K.; Kroll, J. J.; La Fortune, K. N.; Lagin, L. J.; Lakamsani, V. K.; Landen, O. L.; Lane, S. W.; Langdon, A. B.; Langer, S. H.; Lao, N.; Larson, D. W.; Latray, D.; Lau, G. T.; Le Pape, S.; Lechleiter, B. L.; Lee, Y.; Lee, T. L.; Li, J.; Liebman, J. A.; Lindl, J. D.; Locke, S. F.; Loey, H. K.; London, R. A.; Lopez, F. J.; Lord, D. M.; Lowe-Webb, R. R.; Lown, J. G.; Ludwigsen, A. P.; Lum, N. W.; Lyons, R. R.; Ma, T.; MacKinnon, A. J.; Magat, M. D.; Maloy, D. T.; Malsbury, T. N.; Markham, G.; Marquez, R. M.; Marsh, A. A.; Marshall, C. D.; Marshall, S. R.; Maslennikov, I. L.; Mathisen, D. G.; Mauger, G. J.; Mauvais, M.-Y.; McBride, J. A.; McCarville, T.; McCloud, J. B.; McGrew, A.; McHale, B.; Macphee, A. G.; Meeker, J. F.; Merill, J. S.; Mertens, E. P.; Michel, P. A.; Miller, M. G.; Mills, T.; Milovich, J. L.; Miramontes, R.; Montesanti, R. C.; Montoya, M. M.; Moody, J.; Moody, J. D.; Moreno, K. A.; Morris, J.; Morriston, K. M.; Nelson, J. R.; Neto, M.; Neumann, J. D.; Ng, E.; Ngo, Q. M.; Olejniczak, B. L.; Olson, R. E.; Orsi, N. L.; Owens, M. W.; Padilla, E. H.; Pannell, T. M.; Parham, T. G.; Patterson, R. W., Jr.; Pavel, G.; Prasad, R. R.; Pendlton, D.; Penko, F. A.; Pepmeier, B. L.; Petersen, D. E.; Phillips, T. W.; Pigg, D.; Piston, K. W.; Pletcher, K. D.; Powell, C. L.; Radousky, H. B.; Raimondi, B. S.; Ralph, J. E.; Rampke, R. L.; Reed, R. K.; Reid, W. A.; Rekow, V. V.; Reynolds, J. L.; Rhodes, J. J.; Richardson, M. J.; Rinnert, R. J.; Riordan, B. P.; Rivenes, A. S.; Rivera, A. T.; Roberts, C. J.; Robinson, J. A.; Robinson, R. B.; Robison, S. R.; Rodriguez, O. R.; Rogers, S. P.; Rosen, M. D.; Ross, G. F.; Runkel, M.; Runtal, A. S.; Sacks, R. A.; Sailors, S. F.; Salmon, J. T.; Salmonson, J. D.; Saunders, R. L.; Schaffer, J. R.; Schindler, T. M.; Schmitt, M. J.; Schneider, M. B.; Segraves, K. S.; Shaw, M. J.; Sheldrick, M. E.; Shelton, R. T.; Shiflett, M. K.; Shiromizu, S. J.; Shor, M.; Silva, L. L.; Silva, S. A.; Skulina, K. M.; Smauley, D. A.; Smith, B. E.; Smith, L. K.; Solomon, A. L.; Sommer, S.; Soto, J. G.; Spafford, N. I.; Speck, D. E.; Springer, P. T.; Stadermann, M.; Stanley, F.; Stone, T. G.; Stout, E. A.; Stratton, P. L.; Strausser, R. J.; Suter, L. J.; Sweet, W.; Swisher, M. F.; Tappero, J. D.; Tassano, J. B.; Taylor, J. S.; Tekle, E. A.; Thai, C.; Thomas, C. A.; Thomas, A.; Throop, A. L.; Tietbohl, G. L.; Tillman, J. M.; Town, R. P. J.; Townsend, S. L.; Tribbey, K. L.; Trummer, D.; Truong, J.; Vaher, J.; Valadez, M.; van Arsdall, P.; van Prooyen, A. J.; Vergel de Dios, E. O.; Vergino, M. D.; Vernon, S. P.; Vickers, J. L.; Villanueva, G. T.; Vitalich, M. A.; Vonhof, S. A.; Wade, F. E.; Wallace, R. J.; Warren, C. T.; Warrick, A. L.; Watkins, J.; Weaver, S.; Wegner, P. J.; Weingart, M. A.; Wen, J.; White, K. S.; Whitman, P. K.; Widmann, K.; Widmayer, C. C.; Wilhelmsen, K.; Williams, E. A.; Williams, W. H.; Willis, L.; Wilson, E. F.; Wilson, B. A.; Witte, M. C.; Work, K.; Yang, P. S.; Young, B. K.; Youngblood, K. P.; Zacharias, R. A.; Zaleski, T.; Zapata, P. G.; Zhang, H.; Zielinski, J. S.; Kline, J. L.; Kyrala, G. A.; Niemann, C.; Kilkenny, J. D.; Nikroo, A.; van Wonterghem, B. M.; Atherton, L. J.; Moses, E. I.
2011-02-01
We demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.2 MJ delivered by 192 ultraviolet laser beams on the National Ignition Facility. Laser backscatter measurements show that these hohlraums absorb 87% to 91% of the incident laser power resulting in peak radiation temperatures of TRAD=300eV and a symmetric implosion to a 100μm diameter hot core.
LMJ Target design with the A1040 CH-ignition capsule in a cocktail holraum
NASA Astrophysics Data System (ADS)
Malinie, G.; Boniface, C.
2008-11-01
The A1040 indirect-drive ignition capsule was originally designed for the ``Full LMJ'' 240-beam configuration. An ``Ignition milestone'' has been scheduled, when the LMJ will be only partly completed, with a 160-beam, 2-cone configuration. A first approach to meet this milestone is to scale down the capsule and hohlraum of the full LMJ design. Here we use a different approach and show the A1040 ``as is'' can still meet the milestone, provided that a suitable cocktail-walled rugby hohlraum is used to drive the capsule. This is because this kind of hohlraum has a better energetic efficiency than the gold-walled cylinder originally used. From 1D and 2D integrated simulations, we investigate the influence of various parameters of the design, such as the shape of the four steps of the laser pulse, the density of the H/He gas filling of the hohlraum, and the effect of a thin gold coating on the outer surface of the polyimid window used to contain the gas.
Three-dimensional modeling of direct-drive cryogenic implosions on OMEGA
Igumenshchev, I. V.; Goncharov, V. N.; Marshall, F. J.; ...
2016-05-04
The effects of large-scale (with Legendre modes ≲10) laser-imposed nonuniformities in direct-drive cryogenic implosions on the OMEGA laser system are investigated using three-dimension hydrodynamic simulations performed using a newly developed code ASTER. Sources of these nonuniformities include an illumination pattern produced by 60 OMEGA laser beams, capsule offsets (~10 to 20 μm), and imperfect pointing, energy balance, and timing of the beams (with typical σ rms ~10 μm, 10%, and 5 ps, respectively). Two implosion designs using 26-kJ triple-picket laser pulses were studied: a nominal design, in which a 880-μm-diameter capsule is illuminated by the same-diameter beams, and a “R75”more » design using a capsule of 900 μm in diameter and beams of 75% of this diameter. Simulations found that nonuniformities because of capsule offsets and beam imbalance have the largest effect on implosion performance. These nonuniformities lead to significant distortions of implosion cores resulting in an incomplete stagnation. The shape of distorted cores is well represented by neutron images, but loosely in x-rays. Simulated neutron spectra from perturbed implosions show large directional variations and up to ~ 2 keV variation of the hot spot temperature inferred from these spectra. The R75 design is more hydrodynamically efficient because of mitigation of crossed-beam energy transfer, but also suffers more from the nonuniformities. Furthermore, simulations predict a performance advantage of this design over the nominal design when the target offset and beam imbalance σ rms are reduced to less than 5 μm and 5%, respectively.« less
Three-dimensional modeling of direct-drive cryogenic implosions on OMEGA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Igumenshchev, I. V.; Goncharov, V. N.; Marshall, F. J.
The effects of large-scale (with Legendre modes ≲10) laser-imposed nonuniformities in direct-drive cryogenic implosions on the OMEGA laser system are investigated using three-dimension hydrodynamic simulations performed using a newly developed code ASTER. Sources of these nonuniformities include an illumination pattern produced by 60 OMEGA laser beams, capsule offsets (~10 to 20 μm), and imperfect pointing, energy balance, and timing of the beams (with typical σ rms ~10 μm, 10%, and 5 ps, respectively). Two implosion designs using 26-kJ triple-picket laser pulses were studied: a nominal design, in which a 880-μm-diameter capsule is illuminated by the same-diameter beams, and a “R75”more » design using a capsule of 900 μm in diameter and beams of 75% of this diameter. Simulations found that nonuniformities because of capsule offsets and beam imbalance have the largest effect on implosion performance. These nonuniformities lead to significant distortions of implosion cores resulting in an incomplete stagnation. The shape of distorted cores is well represented by neutron images, but loosely in x-rays. Simulated neutron spectra from perturbed implosions show large directional variations and up to ~ 2 keV variation of the hot spot temperature inferred from these spectra. The R75 design is more hydrodynamically efficient because of mitigation of crossed-beam energy transfer, but also suffers more from the nonuniformities. Furthermore, simulations predict a performance advantage of this design over the nominal design when the target offset and beam imbalance σ rms are reduced to less than 5 μm and 5%, respectively.« less
2011-01-01
ABSTRACT Purpose: The purpose of this case study is to describe the management of a female patient with chronic left low back pain and sacroiliac joint pain (LBP/SIJP) using unique unilateral exercises developed by the Postural Restoration Institute (PRI) to address pelvic asymmetry and left hip capsule restriction, which is consistent with a Right Handed and Left Anterior Interior Chain pattern of postural asymmetry. Client Description: The client was 65-year-old woman with a 10-month history of constant left LBP/SIJP and leg pain. Intervention: The patient was seen six times to correct pelvic position/posture and left hip posterior capsule restriction via (1) muscle activation (left hamstrings, adductor magnus, and anterior gluteus medius) and (2) left hip adduction to lengthen the left posterior capsule/ischiofemoral ligament. Stabilization exercises included bilateral hamstrings, gluteus maximus, adductors, and abdominals to maintain pelvic position/posture. Measures and Outcome: Left Ober's test (initially positive) was negative at discharge. Pain as measured on the Numeric Pain Rating Scale (initially 1/10 at best and 8/10 at worst) was 0/10–0/10 at discharge. Oswestry Disability Index score (initially 20%) was 0% at discharge. The patient no longer had numbness in her left leg, and sexual intercourse had become pain free. Implications: Interventions to restore and maintain the optimal position of pelvis and hip (femoral head in the acetabulum) may be beneficial for treating patients with chronic LBP/SIJP. The patient's pain was eliminated 13 days after she first performed three exercises to reposition the pelvis and restore left posterior hip capsule extensibility and internal rotation. PMID:22379254
Influence and measurement of mass ablation in ICF implosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spears, B K; Hicks, D; Velsko, C
2007-09-05
Point design ignition capsules designed for the National Ignition Facility (NIF) currently use an x-ray-driven Be(Cu) ablator to compress the DT fuel. Ignition specifications require that the mass of unablated Be(Cu), called residual mass, be known to within 1% of the initial ablator mass when the fuel reaches peak velocity. The specifications also require that the implosion bang time, a surrogate measurement for implosion velocity, be known to +/- 50 ps RMS. These specifications guard against several capsule failure modes associated with low implosion velocity or low residual mass. Experiments designed to measure and to tune experimentally the amount ofmore » residual mass are being developed as part of the National Ignition Campaign (NIC). Tuning adjustments of the residual mass and peak velocity can be achieved using capsule and laser parameters. We currently plan to measure the residual mass using streaked radiographic imaging of surrogate tuning capsules. Alternative techniques to measure residual mass using activated Cu debris collection and proton spectrometry have also been developed. These developing techniques, together with bang time measurements, will allow us to tune ignition capsules to meet NIC specs.« less
Development of thermal protection system of the MUSES-C/DASH reentry capsule
NASA Astrophysics Data System (ADS)
Yamada, Tetsuya; Inatani, Yoshifumi; Honda, Masahisa; Hirai, Ken'ich
2002-07-01
In the final phase of the MUSES-C mission, a small capsule with asteroid sample conducts reentry flight directly from the interplanetary transfer orbit at the velocity over 12 km/s. The severe heat flux, the complicated functional requirements, and small weight budget impose several engineering challenges on the designing of the thermal protection system of the capsule. The heat shield is required to function not only as ablator but also as a structural component. The cloth-layered carbon-phenolic ablator, which has higher allowable stress, is developed in newly-devised fabric method for avoiding delamination due to the high aerodynamic heating. The ablation analysis code, which takes into account of the effect of pyrolysis gas on the surface recession rate, has been developed and verified in the arc-heating tests in the facility environment of broad range of enthalpy level. The capsule was designed to be ventilated during the reentry flight up to about atmospheric pressure by the time of parachute deployment by being sealed with porous flow-restrict material. The designing of the thermal protection system, the hardware specifications, and the ground-based test programs of both MUSES-C and DASH capsule are summarized and discussed here in this paper.
Anterior capsule tear after laser iridotomy complicating phacoemulsification
Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang
2011-01-01
A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy was completed with scissors. To the best of our knowledge the surgical management of cataract in the presence of anterior capsule rupture as a result of LPI has not been reported. Awareness of this potential complication of LPI will aid in planning for successful phacoemulsification cataract surgery. PMID:23960943
Katagiri, Kiyofumi; Shishijima, Yoshinori; Koumoto, Kunihito; Inumaru, Kei
2018-01-01
pH-Responsive smart capsules were developed by the layer-by-layer assembly with a colloidtemplating technique. Polystyrene (PS) particles were employed as core templates. Acid-soluble inorganic nanosheets were prepared from Mg-Al layered double hydroxide (LDH) by an exfoliation technique. LDH nanosheets and anionic polyelectrolytes were alternatively deposited on PS core particles by the layer-by-layer assembly using electrostatic interaction. Hollow capsules were obtained by the removal of the PS core particles. The hollow capsules obtained thus were collapsed at acidic conditions by dissolution of LDH nanosheets in the hollow shells. The dissolution rate, i.e., the responsiveness of capsule, is tunable according to the strength of acids.
Capsule endoscopy of the future: What’s on the horizon?
Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro
2015-01-01
Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today’s standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013
The history of time for capsule endoscopy.
Adler, Samuel N
2017-05-01
Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.
Comparative analysis of EPA and DHA in fish oil nutritional capsules by GC-MS.
Yi, Tao; Li, Shuk-Man; Fan, Jia-Yi; Fan, Lan-Lan; Zhang, Zhi-Feng; Luo, Pei; Zhang, Xiao-Jun; Wang, Jian-Gang; Zhu, Lin; Zhao, Zhong-Zhen; Chen, Hu-Biao
2014-12-13
Fish oil is a popular nutritional product consumed in Hong Kong. Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are the two main bioactive components responsible for the health benefits of fish oil. Market survey in Hong Kong demonstrated that various fish oil capsules with different origins and prices are sold simultaneously. However, these capsules are labelled with same ingredient levels, namely EPA 180 mg/g and DHA 120 mg/g. This situation makes the consumers very confused. To evaluate the quality of various fish oil capsules, a comparative analysis of the contents of EPA and DHA in fish oil is crucial. A gas chromatography-mass spectrometry (GC-MS) method was developed for identification and determination of EPA and DHA in fish oil capsules. A comprehensive validation of the developed method was conducted. Ten batches of fish oil capsules samples purchased from drugstores of Hong Kong were analyzed by using the developed method. The present method presented good sensitivity, precision and accuracy. The limits of detection (LOD) for EPA and DHA were 0.08 ng and 0.21 ng, respectively. The relative standard deviation (RSD) values of EPA and DHA for repeatability tests were both less than 1.05%; and the recovery for accuracy test of EPA and DHA were 100.50% and 103.83%, respectively. In ten fish oil samples, the contents of EPA ranged from 39.52 mg/g to 509.16 mg/g, and the contents of DHA ranged from 35.14 mg/g to 645.70 mg/g. The present method is suitable for the quantitative analysis of EPA and DHA in fish oil capsules. There is a significant variation in the contents of the quantified components in fish oil samples, and there is not a linear relationship between price and contents of EPA and DHA. Strict supervision of the labelling of the fish oil capsules is urgently needed.
2-Shock layered tuning campaign
NASA Astrophysics Data System (ADS)
Masse, Laurent; Dittrich, T.; Khan, S.; Kyrala, G.; Ma, T.; MacLaren, S.; Ralph, J.; Salmonson, J.; Tipton, R.; Los Alamos Natl Lab Team; Lawrence Livermore Natl Lab Team
2016-10-01
The 2-Shock platform has been developed to maintain shell sphericity throughout the compression phase of an indirect-drive target implosion and produce a stagnating hot spot in a quasi 1D-like manner. A sub-scale, 1700 _m outer diameter, and thick, 200 _m, uniformly Silicon doped, gas-filled plastic capsule is driven inside a nominal size 5750 _m diameter ignition hohlraum. The hohlraum fill is near vacuum to reduce back-scatter and improve laser/drive coupling. A two-shock pulse of about 1 MJ of laser energy drives the capsule. The thick capsule prevents ablation front feed-through to the imploded core. This platform has demonstrated its efficiency to tune a predictable and reproducible 1-D implosion with a nearly round shape. It has been shown that the high foot performance was dominated by the local defect growth due to the ablation front instability and by the hohlraum radiation asymmetries. The idea here is to take advantage of this 2-Shock platform to design a 1D-like layered implosion and eliminates the deleterious effects of radiation asymmetries and ablation front instability growth. We present the design work and our first experimental results of this near one-dimensional 2-Shock layered design. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.
Friedrich, Kilian; Gehrke, Sven; Stremmel, Wolfgang; Sieg, Andreas
2013-09-01
Capsule endoscopy is the first-line diagnostic technique for the small bowel. However, the inability to visualize the duodenal papilla is an inherent limitation of this method. In the present study, we evaluated feasibility of a newly developed CapsoCam SV1 capsule. This is a prospective dual center study of a newly developed video capsule CapsoCam SV1 from Capsovision, CA, providing panoramic 360° imaging. A high frequency of 20 frames occurs per second for the first 2 h and thereafter 12 frames/s, with a battery life of 15 h. We evaluated feasibility and completeness of small bowel examination together with secondary endpoints of duodenal papilla detection in 33 patients. Patients swallowed the capsules following colonoscopy or were prepared with 2 L of polyethylene glycol solution prior to the examination. All patients swallowed 20 mg of metoclopramide and 160 mg of simethicone 30 min before ingestion of the capsule. Thirty-one of the 33 patients' data could be evaluated. Small bowel examination was complete in all procedures. Mean time to pass the small bowel was 258 ± 136 min. Average small bowel cleanliness was 3.3 ± 0.5. In 71% of the patients, we identified the duodenal papilla. No adverse reaction in relation to the capsule examination was observed. CapsoCam SV1 is a safe and efficient tool in small bowel examination. The duodenal papilla as the only landmark in small bowel is detected in more than 70% of the patients. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
The proposal of the locomotive system for capsule endoscopes.
Watada, Masaya; Ozawa, Ken-ichi
2008-01-01
The capsule endoscope authorized in some countries in late years has the advantage of preparing the observation in difficult small intestines in a past endoscope. However, because the promotion mechanism of a capsule endoscope depends only on the peristaltic motion of a digestive organ, the oversight of change to a morbid state is feared. Authors aim at the achievement of a free movement and remote diagnoses in small intestines, and are developing a locomotive system for capsule endoscopes. This paper describes the proposal of the locomotive system with an electromagnetic actuator, and examination of a simulation model for this locomotive system.
NASA Astrophysics Data System (ADS)
Clark, Daniel
2015-11-01
In order to achieve the several hundred Gbar stagnation pressures necessary for inertial confinement fusion ignition, implosion experiments on the National Ignition Facility (NIF) require the compression of deuterium-tritium fuel layers by a convergence ratio as high as forty. Such high convergence implosions are subject to degradation by a range of perturbations, including the growth of small-scale defects due to hydrodynamic instabilities, as well as longer scale modulations due to radiation flux asymmetries in the enclosing hohlraum. Due to the broad range of scales involved, and also the genuinely three-dimensional (3-D) character of the flow, accurately modeling NIF implosions remains at the edge of current radiation hydrodynamics simulation capabilities. This talk describes the current state of progress of 3-D, high-resolution, capsule-only simulations of NIF implosions aimed at accurately describing the performance of specific NIF experiments. Current simulations include the effects of hohlraum radiation asymmetries, capsule surface defects, the capsule support tent and fill tube, and use a grid resolution shown to be converged in companion two-dimensional simulations. The results of detailed simulations of low foot implosions from the National Ignition Campaign are contrasted against results for more recent high foot implosions. While the simulations suggest that low foot performance was dominated by ablation front instability growth, especially the defect seeded by the capsule support tent, high foot implosions appear to be dominated by hohlraum flux asymmetries, although the support tent still plays a significant role. Most importantly, it is found that a single, standard simulation methodology appears adequate to model both implosion types and gives confidence that such a model can be used to guide future implosion designs toward ignition. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Artist concept of Mercury program study of medical effects and technology
NASA Technical Reports Server (NTRS)
1964-01-01
Artist concept of Mercury program study of medical effects and technology development. Drawing depicts cut-away view of Mercury capsule orbiting the Earth, showing the astronaut and his capsule's hardware.
Antibiotics in surgical treatment of acute abscesses.
Blick, P W; Flowers, M W; Marsden, A K; Wilson, D H; Ghoneim, A T
1980-01-01
A four-way, double-blind, prospective trial of treatment of abscesses by incision, curettage, and primary closure with and without antibiotic cover (clindamycin injection before operation or capsules after operation, or both) was conducted. There was no appreciable difference in mean healing time between the patients given both the antibiotic injection and the antibiotic capsules and those given the injection and placebo capsules, whereas healing times in those given the placebo injection and antibiotic capsules or placebo only were appreciably longer. Four of the patients who were not given the antibiotic injection developed bacteraemia; one patient who was given the antibiotic injection also developed a bacteraemia, but this was caused by clindamycin-resistant bacteria. These results show that a single injection of an effective antibiotic before operation is sufficient to protect the patient against bacteraemia and permit optimum healing. PMID:7000250
NASA Technical Reports Server (NTRS)
Conrad, G. W.; Stephens, A. P.; Conrad, A. H.; Spooner, B. S. (Principal Investigator)
1993-01-01
Fertilized eggs of Ilyanassa obsoleta Stimpson were collected immediately after their deposition in egg capsules. Unopened egg capsules then were affixed to glass slides, and incubated either statically (controls) or on a clinostat (experimentals). After incubation for 9-14 days, hatching occurred sooner and in a higher percentage of clinostated capsules than in controls. Embryos that hatched while undergoing clinostat incubation were abnormal in morphology, whereas other embryos present in non-hatched capsules in the same tubes appeared normal, as did embryos in the control tubes. Although the results are compatible with a conclusion that vector-averaged gravity in the experimental tubes caused the altered development, some other aspects of how the incubations were done may have contributed to the differences between the control and experimental results.
CAPSULE REPORT: AQUEOUS MERCURY TREATMENT
This report describes established technologies and identifies evolving methods for treating aqueous mercury. The information provided encompasses full-, pilot- and bench-scale treatment results as presented in the technical literature. The report describes alternative technologi...
Remote controlled capsules in human drug absorption (HDA) studies.
Wilding, Ian R; Prior, David V
2003-01-01
The biopharmaceutical complexity of today's new drug candidates provides significant challenges for pharmaceutical scientists in terms of both candidate selection and optimizing subsequent development strategy. In addition, life cycle management of marketed drugs has become an important income stream for pharmaceutical companies, but the selection of least risk/highest benefit strategies is far from simple. The proactive adoption of human drug absorption (HDA) studies using remote controlled capsules offers the pharmaceutical scientist significant guidance for planning a route through the maze of product development. This review examines the position of HDA studies in drug development, using a variety of case histories and an insightful update on remote controlled capsules to achieve site-specific delivery.
NASA Astrophysics Data System (ADS)
Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex
2017-03-01
An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.
NASA Astrophysics Data System (ADS)
Magelssen, G. R.; Bradley, P. A.; Tregillis, I. L.; Schmitt, M. J.; Dodd, E. S.; Wysocki, F. J.; Hsu, S. C.; Cobble, J.; Batha, S. H.; Defriend Obrey, K. A.
2010-11-01
Small capsule perturbations may impact our ability to achieve high yields on NIF. Diagnosing the hydrodynamic development and the effect of defects on burn will be difficult. Los Alamos is developing a program to better understand the hydrodynamics of defects and how they influence burn. Our first effort to study the effects of defects was on Omega. Both thin-shelled (exploding pusher) and thick-shelled capsules were shot and the results published [1]. In this work we add experimental shots done recently on Omega. These shots were to complete the study of how the width and depth of the defect affects DT yield. Our AMR code is used to predict the yield. Comparisons between capsule and experimental yields will be given. Experiments are also being designed for Polar direct drive. Our first experiments are being designed to understand the zero-order hydrodynamics with Polar direct drive. Capsules about a millimeter in radius are being designed with one to two dopants in the CH shell for radiograph and MMI usage. Also, to minimize the effect of mix on the radius versus time trajectory, some capsules will replace the DT with Xe.[0pt] [1] Magelssen G. R. et al., to be published in the 2009 IFSA proceedings.
Capsular locomotive microrobot for gastrointestinal tract.
Park, Sukho; Park, Hyunjun; Park, Sungjin; Jee, Changyeol; Kim, Jinseok; Kim, Byungkyu
2006-01-01
Diagnosis using a flexible endoscope in gastro-intestinal tract becomes very important. In addition, the endoscope is a basic tool of diagnosis and treatment for digestive organ. However, the operation of endoscope is very labor intensive work and gives patients some pains. Therefore, the capsule-type endoscope is developed for the diagnosis of digestive organs. For its conveniences for diagnosis, the capsule endoscope comes into the spotlight. However, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. In order to solve these problems, therefore, a locomotive mechanism of capsule endoscopes has being developed. For the locomotion in the gastro-intestinal tract, our proposed capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed locomotive mechanism, a series of in-vitro experiments using small intestine without incision were carried out. In addition, in-vivo animal tests under a general anesthesia are also executed. From the experimental results, we conclude that the proposed locomotive mechanism is not only applicable to micro capsule endoscopes but also effective to advance inside of intestinal tract.
Size-tunable drug-delivery capsules composed of a magnetic nanoshell.
Fuchigami, Teruaki; Kitamoto, Yoshitaka; Namiki, Yoshihisa
2012-01-01
Nano-sized FePt capsules with two types of ultrathin shell were fabricated using a template method for use in a nano-scale drug delivery system. One capsule was composed of an inorganic-organic hybrid shell of a water-soluble polymer and FePt nanoparticles, and the other capsule was composed of a network of fused FePt nanoparticles. We demonstrated that FePt nanoparticles selectively accumulated on the polymer molecules adsorbed on the template silica particles, and investigated the morphologies of the particle accumulation by changing the concentration of the polymer solution with which the template particles were treated. Capsular size was reduced from 340 to less than 90 nm by changing the size of the silica template particles, and the shell thickness was controlled by changing the amount of FePt nanoparticles adsorbed on the template particles. The hybrid shell was maintained by the connection of FePt nanoparticles and polymer molecules, and the shell thickness was 10 nm at the maximum. The FePt network shell was fabricated by hydrothermal treatment of the FePt/polymer-modified silica composite particles. The FePt network shell was produced from only the FePt alloy, and the shell thickness was 3 nm. Water-soluble anti-cancer drugs could be loaded into the hollow space of FePt network capsules, and lipid-coated FePt network capsules loaded with anti-cancer drugs showed cellular toxicity. The nano-sized capsular structure and the ultrathin shell suggest applicability as a drug carrier in magnetically guided drug delivery systems.
Size-tunable drug-delivery capsules composed of a magnetic nanoshell
Fuchigami, Teruaki; Kitamoto, Yoshitaka; Namiki, Yoshihisa
2012-01-01
Nano-sized FePt capsules with two types of ultrathin shell were fabricated using a template method for use in a nano-scale drug delivery system. One capsule was composed of an inorganic-organic hybrid shell of a water-soluble polymer and FePt nanoparticles, and the other capsule was composed of a network of fused FePt nanoparticles. We demonstrated that FePt nanoparticles selectively accumulated on the polymer molecules adsorbed on the template silica particles, and investigated the morphologies of the particle accumulation by changing the concentration of the polymer solution with which the template particles were treated. Capsular size was reduced from 340 to less than 90 nm by changing the size of the silica template particles, and the shell thickness was controlled by changing the amount of FePt nanoparticles adsorbed on the template particles. The hybrid shell was maintained by the connection of FePt nanoparticles and polymer molecules, and the shell thickness was 10 nm at the maximum. The FePt network shell was fabricated by hydrothermal treatment of the FePt/polymer-modified silica composite particles. The FePt network shell was produced from only the FePt alloy, and the shell thickness was 3 nm. Water-soluble anti-cancer drugs could be loaded into the hollow space of FePt network capsules, and lipid-coated FePt network capsules loaded with anti-cancer drugs showed cellular toxicity. The nano-sized capsular structure and the ultrathin shell suggest applicability as a drug carrier in magnetically guided drug delivery systems. PMID:23507895
Microencapsulation of 2-octylcyanoacrylate tissue adhesive for self-healing acrylic bone cement.
Brochu, Alice B W; Chyan, William J; Reichert, William M
2012-10-01
Here, we report the first phase of developing self-healing acrylic bone cement: the preparation and characterization of polyurethane (PUR) microcapsules containing a medical cyanoacrylate tissue adhesive. Capsules were prepared by interfacial polymerization of a toluene-2,4-diisocyanate-based polyurethane prepolymer with 1,4-butanediol to encapsulate 2-octylcyanoacrylate (OCA). Various capsule characteristics, including: resultant morphology, average size and size distribution, shell thickness, content and reactivity of encapsulated agent, and shelf life are investigated and their reliance on solvent type and amount, surfactant type and amount, temperature, pH, agitation rate, reaction time, and mode of addition of the oil phase to the aqueous phase are presented. Capsules had average diameters ranging from 74 to 222 μm and average shell thicknesses ranging from 1.5 to 6 μm. The capsule content was determined via thermogravimetric analysis and subsequent analysis of the capsules following up to 8 weeks storage revealed minimal loss of core contents. Mechanical testing of OCA-containing capsules showed individual capsules withstood compressive forces up to a few tenths of Newtons, and the contents released from crushed capsules generated tensile adhesive forces of a few Newtons. Capsules were successfully mixed into the poly(methyl methacrylate) bone cement, surviving the mixing process, exposure to methyl methacrylate monomer, and the resulting exothermic matrix curing. Copyright © 2012 Wiley Periodicals, Inc.
State diagram for adhesion dynamics of deformable capsules under shear flow.
Luo, Zheng Yuan; Bai, Bo Feng
2016-08-17
Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.
Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.
Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier
2014-11-14
Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.
Flow visualization around a rotating body in a wind tunnel
NASA Astrophysics Data System (ADS)
Hiraki, K.; Zaitsu, D.; Yanaga, Y.; Kleine, H.
2017-02-01
The rotational behavior of capsule-shaped models is investigated in the transonic wind tunnel of JAXA. A special support is developed to allow the model to rotate around the pitch, yaw and roll axes. This 3-DOF free rotational mounting apparatus achieves the least frictional torque from the support and the instruments. Two types of capsule models are prepared, one is drag type (SPH model) and the other is lift type (HTV-R model). The developed mounting apparatus is used in the wind tunnel tests with these capsule models. In a flow of Mach 0.9, the SPH model exhibits oscillations in pitch and yaw, and it rolls half a turn during the test. Similarly, the HTV-R model exhibits pitch and yaw oscillations in a flow of Mach 0.5. Moreover, it rolls multiple times during the test. In order to investigate the flow field around the capsule, the combined technique of color schlieren and surface tufts is applied. This visualization clearly shows the flow reattachment on the back surface of a capsule, which is suspected to induce the rapid rolling motion.
A robust real-time abnormal region detection framework from capsule endoscopy images
NASA Astrophysics Data System (ADS)
Cheng, Yanfen; Liu, Xu; Li, Huiping
2009-02-01
In this paper we present a novel method to detect abnormal regions from capsule endoscopy images. Wireless Capsule Endoscopy (WCE) is a recent technology where a capsule with an embedded camera is swallowed by the patient to visualize the gastrointestinal tract. One challenge is one procedure of diagnosis will send out over 50,000 images, making physicians' reviewing process expensive. Physicians' reviewing process involves in identifying images containing abnormal regions (tumor, bleeding, etc) from this large number of image sequence. In this paper we construct a novel framework for robust and real-time abnormal region detection from large amount of capsule endoscopy images. The detected potential abnormal regions can be labeled out automatically to let physicians review further, therefore, reduce the overall reviewing process. In this paper we construct an abnormal region detection framework with the following advantages: 1) Trainable. Users can define and label any type of abnormal region they want to find; The abnormal regions, such as tumor, bleeding, etc., can be pre-defined and labeled using the graphical user interface tool we provided. 2) Efficient. Due to the large number of image data, the detection speed is very important. Our system can detect very efficiently at different scales due to the integral image features we used; 3) Robust. After feature selection we use a cascade of classifiers to further enforce the detection accuracy.
Non-LTE modeling for the National Ignition Facility (and beyond)
NASA Astrophysics Data System (ADS)
Scott, H. A.; Hammel, B. A.; Hansen, S. B.
2012-05-01
Considerable progress has been made in the last year in the study of laser-driven inertial confinement fusion at the National Ignition Facility (NIF). Experiments have demonstrated symmetric capsule implosions with plasma conditions approaching those required for ignition. Improvements in computational models - in large part due to advances in non-LTE modeling - have resulted in simulations that match experimental results quite well for the X-ray drive, implosion symmetry and total wall emission [1]. Non-LTE modeling is a key part of the NIF simulation effort, affecting several aspects of experimental design and diagnostics. The X-rays that drive the capsule arise from high-Z material ablated off the hohlraum wall. Current capsule designs avoid excessive preheat from high-energy X-rays by shielding the fuel with a mid-Z dopant, which affects the capsule dynamics. The dopant also mixes into the hot spot through hydrodynamic instabilities, providing diagnostic possibilities but potentially impacting the energy balance of the capsule [2]. Looking beyond the NIF, a proposed design for a fusion reactor chamber depends on lowdensity high-Z gas absorbing X-rays and particles to protect the first wall [3]. These situations encompass a large range of temperatures, densities and spatial scales. They each emphasize different aspects of atomic physics and present a variety of challenges for non-LTE modeling. We discuss the relevant issues and summarize the current state of the modeling effort for these applications.
Albumin/asparaginase capsules prepared by ultrasound to retain ammonia.
Tinoco, Ana; Ribeiro, Artur; Oliveira, César; Parpot, Pier; Gomes, Andreia; Cavaco-Paulo, Artur
2016-11-01
Asparaginase reduces the levels of asparagine in blood, which is an essential amino acid for the proliferation of lymphoblastic malign cells. Asparaginase converts asparagine into aspartic acid and ammonia. The accumulation of ammonia in the bloodstream leads to hyperammonemia, described as one of the most significant side effects of asparaginase therapy. Therefore, there is a need for asparaginase formulations with the potential to reduce hyperammonemia. We incorporated 2 % of therapeutic enzyme in albumin-based capsules. The presence of asparaginase in the interface of bovine serum albumin (BSA) capsules showed the ability to hydrolyze the asparagine and retain the forming ammonia at the surface of the capsules. The incorporation of Poloxamer 407 in the capsule formulation further increased the ratio aspartic acid/ammonia from 1.92 to 2.46 (and 1.10 from the free enzyme), decreasing the levels of free ammonia. This capacity to retain ammonia can be due to electrostatic interactions and retention of ammonia at the surface of the capsules. The developed BSA/asparaginase capsules did not cause significant cytotoxic effect on mouse leukemic macrophage cell line RAW 264.7. The new BSA/asparaginase capsules could potentially be used in the treatment of acute lymphoblastic leukemia preventing hyperammonemia associated with acute lymphoblastic leukemia (ALL) treatment with asparaginase.
Closed Loop Control of a Tethered Magnetic Capsule Endoscope
Taddese, Addisu Z.; Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro
2017-01-01
Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy. PMID:28286886
Closed Loop Control of a Tethered Magnetic Capsule Endoscope.
Taddese, Addisu Z; Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro
2016-06-01
Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.
Interaction model between capsule robot and intestine based on nonlinear viscoelasticity.
Zhang, Cheng; Liu, Hao; Tan, Renjia; Li, Hongyi
2014-03-01
Active capsule endoscope could also be called capsule robot, has been developed from laboratory research to clinical application. However, the system still has defects, such as poor controllability and failing to realize automatic checks. The imperfection of the interaction model between capsule robot and intestine is one of the dominating reasons causing the above problems. A model is hoped to be established for the control method of the capsule robot in this article. It is established based on nonlinear viscoelasticity. The interaction force of the model consists of environmental resistance, viscous resistance and Coulomb friction. The parameters of the model are identified by experimental investigation. Different methods are used in the experiment to obtain different values of the same parameter at different velocities. The model is proved to be valid by experimental verification. The achievement in this article is the attempted perfection of an interaction model. It is hoped that the model can optimize the control method of the capsule robot in the future.
Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive
NASA Astrophysics Data System (ADS)
Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping
2016-08-01
The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.
Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gu, Jianfa, E-mail: gu-jianfa@iapcm.ac.cn; Dai, Zhensheng, E-mail: dai-zhensheng@iapcm.ac.cn; Song, Peng
2016-08-15
The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and themore » final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.« less
Gish, Stacey R.; Maier, Ezekiel J.; Haynes, Brian C.; Santiago-Tirado, Felipe H.; Srikanta, Deepa L.; Ma, Cynthia Z.; Li, Lucy X.; Williams, Matthew; Crouch, Erika C.; Khader, Shabaana A.
2016-01-01
ABSTRACT Cryptococcus neoformans is a ubiquitous, opportunistic fungal pathogen that kills over 600,000 people annually. Here, we report integrated computational and experimental investigations of the role and mechanisms of transcriptional regulation in cryptococcal infection. Major cryptococcal virulence traits include melanin production and the development of a large polysaccharide capsule upon host entry; shed capsule polysaccharides also impair host defenses. We found that both transcription and translation are required for capsule growth and that Usv101 is a master regulator of pathogenesis, regulating melanin production, capsule growth, and capsule shedding. It does this by directly regulating genes encoding glycoactive enzymes and genes encoding three other transcription factors that are essential for capsule growth: GAT201, RIM101, and SP1. Murine infection with cryptococci lacking Usv101 significantly alters the kinetics and pathogenesis of disease, with extended survival and, unexpectedly, death by pneumonia rather than meningitis. Our approaches and findings will inform studies of other pathogenic microbes. PMID:27094327
Frey, Anne; Godin, Béatrice; Bonnet, Magda; Sotta, Bruno; Marion-Poll, Annie
2004-04-01
The role of maternally derived abscisic acid (ABA) during seed development has been studied using ABA-deficient mutants of Nicotiana plumbaginifolia Viviani. ABA deficiency induced seed abortion, resulting in reduced seed yield, and delayed growth of the remaining embryos. Mutant grafting onto wild-type stocks and reciprocal crosses indicated that maternal ABA, synthesized in maternal vegetative tissues and translocated to the seed, promoted early seed development and growth. Moreover ABA deficiency delayed both seed coat pigmentation and capsule dehiscence. Mutant grafting did not restore these phenotypes, indicating that ABA synthesized in the seed coat and capsule envelope may have a positive effect on capsule and testa maturation. Together these results shed light on the positive role of maternal ABA during N. plumbaginifolia seed development.
Magnetized HDC ignition capsules for yield enhancement and implosion magnetohydrodynamics
NASA Astrophysics Data System (ADS)
Zimmerman, G.; Ho, D.; Perkins, J.; Logan, G.; Hawkins, S.; Rhodes, M.
2014-10-01
Imposing a magnetic field on capsules can turn capsules that fail, because of low 1-D margin, into igniting capsules that give yield in the MegaJoule range. The imposed magnetic field can be amplified by up to O(103) as it is being compressed by the imploding shell, e.g. if the initial field is 50 T, then the field in the hot spot of the assembled configuration can reach >104 T. (We are currently designing hardware that can provide a field in the 50 T range inside NIF hohlraums.) With this highly compressed field strength, the gyro radius of alpha particles becomes smaller than the hot spot size. Consequently, the heating of the hot spot becomes more efficient. The imposed field can also prevent hot electrons in the holhraum from reaching the capsule. We choose capsules with high-density carbon (HDC) ablators for this study. HDC capsules have good 1-D performance and also have short pulses (10 ns or less), allowing the use of low gas-filled or near-vacuum hohlraums which provide high coupling efficiency. We describe a 2-D simulation of a 3-shock HDC capsule. We will show detailed magnetohydrodynamic evolution of the implosion. HDC capsules with 2-shock pulses have low margin because of their high adiabat, and it is difficult to achieve ignition in realistic 2-D simulations. The improvement in performance for 2-shock magnetized capsules will be presented. This work was supported by LLNL Laboratory Directed Research and Development LDRD 14-ER-028 under Contract DE-AC52-07NA27344.
Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.
Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho
2015-03-01
Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.
Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract
NASA Astrophysics Data System (ADS)
Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay
2011-03-01
Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.
2011-12-02
CAPE CANAVERAL, Fla. – From a boat in the Atlantic Ocean, workers secure lines to an Orion flight test capsule during preparations for testing the capsule as their colleagues look on from the deck of NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Using gamma-ray emission to measure areal density of inertial confinement fusion capsulesa)
NASA Astrophysics Data System (ADS)
Hoffman, N. M.; Wilson, D. C.; Herrmann, H. W.; Young, C. S.
2010-10-01
Fusion neutrons streaming from a burning inertial confinement fusion capsule generate gamma rays via inelastic nuclear scattering in the ablator of the capsule. The intensity of gamma-ray emission is proportional to the product of the ablator areal density (ρR) and the yield of fusion neutrons, so by detecting the gamma rays we can infer the ablator areal density, provided we also have a measurement of the capsule's total neutron yield. In plastic-shell capsules, for example, C12 nuclei emit gamma rays at 4.44 MeV after excitation by 14.1 MeV neutrons from D+T fusion. These gamma rays can be measured by a new gamma-ray detector under development. Analysis of predicted signals is in progress, with results to date indicating that the method promises to be useful for diagnosing imploded capsules.
Remote micro-encapsulation of curium-gold cermets
NASA Astrophysics Data System (ADS)
Coops, M. S.; Voegele, A. L.; Hayes, W. N.; Sisson, D. H.
1982-09-01
A technique has been developed to produce miniature, high-density capsules of curium-244 oxide contained in three concentric jackets of metallic gold or silver. The final capsules are right circular cylinders, 6.350 mm diameter by (3.18±0.05) mm long, with a minimum density of 11.0 g/cm 3. Each level of containment was soldered or brazed closed, with the outer surface free of detectable alpha contamination. Fabrication was performed in three separate small cells operated by standard master-slave manipulators. Production capsules have been stored for up to five years without indication of dimensional growth or leakage of radioactive contents. The dimensional stability of the capsules is attributed to the microporous structure of the plated-gold structure which permits helium gas resulting from alpha decay to diffuse through the capsule wall while retaining all radioactive materials.
Howard-Thompson, Amanda; Dutton, Anna; Hoover, Robert; Goodfred, Jennifer
2014-12-01
A brand of fish oil capsules contains omega-3 fatty acids obtained from several fish sources. Although the manufacturer calls for caution in patients with fish hypersensitivity, insufficient data is available to make a definitive recommendation regarding its use in this population. A patient with documented seafood allergy presented to the emergency department 4 days after the initiation of prescription brand name fish oil capsules complaining of chest tightness, shortness of breath, tingling of upper extremities, flushing, and pruritus that was minimally relieved by excessive nonprescription diphenhydramine administration. During subsequent follow-up, the patient reported that all symptoms had resolved within 5 days of discontinuing the medication and 3 days of disposing of her pillbox and all medications that had come in contact with the fish oil capsules. Due to the patient's allergic history, timing of onset/offset of the reaction, laboratory evidence, and the use of the Naranjo probability scale, prescription fish oil capsules were deemed the probable cause of this patient's pruritus and flushing of the face and trunk. Practitioners and patients should always ensure they have an updated list of allergies within the patient's medical record that includes medications as well as foods and food additives.
Factor structure of the Shoulder Pain and Disability Index in patients with adhesive capsulitis.
Tveitå, Einar Kristian; Sandvik, Leiv; Ekeberg, Ole Marius; Juel, Niels Gunnar; Bautz-Holter, Erik
2008-07-17
The Shoulder Pain and Disability Index (SPADI) is a self-administered questionnaire that aims to measure pain and disability associated with shoulder disease. It consists of a pain section and a disability section with 13 items being responded to on visual analogue scales. Few researchers have investigated SPADI validity in specified diagnostic groups, although the selection of an evaluative instrument should be based on evidence of validity in the target patient group. The aim of the present study was to investigate factor structure of the SPADI in a study population of patients with adhesive capsulitis. The questionnaire was administered to 191 patients with adhesive capsulitis. Descriptive statistics for items and a comparison of scores for the two subscales were produced. Internal consistency was analyzed by use of the Cronbach alpha and a principal components analysis with varimax rotation was conducted. Study design was cross-sectional. Two factors were extracted, but the factor structure failed to support the original division of items into separate pain and disability sections. We found minimal evidence to justify the use of separate subscales for pain and disability. It is our impression that the SPADI should be viewed as essentially unidimensional in patients with adhesive capsulitis.
First shock tuning and backscatter measurements for large case-to-capsule ratio beryllium targets
NASA Astrophysics Data System (ADS)
Loomis, Eric; Yi, Austin; Kline, John; Kyrala, George; Simakov, Andrei; Wilson, Doug; Ralph, Joe; Dewald, Eduard; Strozzi, David; Celliers, Peter; Millot, Marius; Tommasini, Riccardo
2016-10-01
The current under performance of target implosions on the National Ignition Facility (NIF) has necessitated scaling back from high convergence ratio to access regimes of reduced physics uncertainties. These regimes, we expect, are more predictable by existing radiation hydrodynamics codes giving us a better starting point for isolating key physics questions. One key question is the lack of predictable in-flight and hot spot shape due to a complex hohlraum radiation environment. To achieve more predictable, shape tunable implosions we have designed and fielded a large 4.2 case-to-capsule ratio (CCR) target at the NIF using 6.72 mm diameter Au hohlraums and 1.6 mm diameter Cu-doped Be capsules. Simulations show that at these dimensions during a 10 ns 3-shock laser pulse reaching 270 eV hohlraum temperatures, the interaction between hohlraum and capsule plasma, which at lower CCR lead to beam propagation impedance by artificial plasma stagnation, are reduced. In this talk we will present measurements of early time drive symmetry using two-axis line-imaging velocimetry (VISAR) and streaked radiography measuring velocity of the imploding shell and their comparisons to post-shot calculations using the code HYDRA (Lawrence Livermore National Laboratory).
The ePLAS code for Ignition Studies
NASA Astrophysics Data System (ADS)
Faehl, R. J.; Mason, R. J.; Kirkpatrick, R. C.
2012-10-01
The ePLAS code is a multi-fluid/PIC hybrid developing self-consistent E & B-fields by the Implicit Moment Method for stable calculations of high density plasma problems with voids on the electron Courant time scale. See: http://www.researchapplicationscorp.com. Here, we outline typical applications to: 1) short pulse driven electron transport along void (or high Z) insulated wires, and 2) the 2D development of shock ignition pressure peaks with B-fields. We outline the code's recent inclusion of SESAME EOS data, a DT/DD burn capability, a new option for K-alpha imaging of modeling output, and demonstrate a foil expansion tracked with either fluid or particle ions. Also, we describe a new super-hybrid extension of our implicit solver that permits full target dynamics studies on the ion Courant scale. Finally, we will touch on the very recent application of ePLAS to possible non-local/kinetic hydro effects NIF capsules.
Space processing experimental apparatus - A survey
NASA Technical Reports Server (NTRS)
Siebel, M. P.
1977-01-01
The processing of materials in a low-g environment was started approximately 10 years ago. This article surveys the apparatus developed during that period. A low-g environment occurs naturally in a free-flying spacecraft (e.g., in manned flights such as Apollo, Skylab, and ASTP); low-g conditions also occur in other free-falling bodies such as sounding rockets and drop tower capsules. Apparatus has been developed for all these craft. Most of the apparatus described serves to melt and resolidify materials in low g; the material may be contained or, by virtue of the environment, freely floating. Other apparatus for separation of intimately mixed components or species is also described. A general conclusion is drawn that the apparatus addresses only a few of the possibilities available, is still at the experimental stage, and is of laboratory scale. It is predicted that processes showing promise will be scaled up to derive economic advantages in the Shuttle era of space flight.
Oh, D Alexander; Parikh, Neha; Khurana, Varun; Cognata Smith, Christina; Vetticaden, Santosh
2017-01-01
Dronabinol is a pharmaceutical tetrahydrocannabinol originally developed as an oral capsule. A dronabinol oral solution was recently approved, and the effects of food on absorption and bioavailability of the oral solution versus capsules were compared in an open-label, single-dose, 3-period crossover study. Healthy volunteers were randomized to either dronabinol oral solution 4.25 mg (fed) or dronabinol capsule 5 mg (fed or fasted). Dosing was separated by a 7-day washout period. Plasma pharmacokinetics were evaluated for dronabinol and its major metabolite, 11-hydroxy-delta-9-tetrahydrocannabinol (11-OH-Δ9-THC). Pharmacokinetic data were available for analysis in 54 volunteers. In the fed state, initial dronabinol absorption was faster with oral solution versus capsule (mean time to the first measurable concentration, 0.15 vs 2.02 hours, respectively), with 100% and 15% of volunteers, respectively, having detectable plasma dronabinol levels 30 minutes postdose. There was less interindividual variability in plasma dronabinol concentration during early absorption with oral solution versus capsule. Compared with the fasted state, mean area under the plasma concentration–time curve from time zero to the last measurable concentration (AUC0−t) increased by 2.1- and 2.4-fold for dronabinol oral solution and capsule, respectively, when taken with food. Mean time to maximum plasma concentration was similarly delayed for dronabinol oral solution with food (7.7 hours) and capsule with food (5.6 hours) versus capsule with fasting (1.7 hours). Under fed conditions, AUC0−t and area under the plasma concentration–time curve from time zero to infinity were similar for the oral solution versus capsule based on 11-OH-Δ9-THC levels. An appreciable food effect was observed for dronabinol oral solution and capsules. Dronabinol oral solution may offer therapeutic benefit to patients, given its rapid and lower interindividual absorption variability versus dronabinol capsule. PMID:28138268
Sun, Jian-Hui; Huo, Hai-Ru; Li, Xiao-Qin; Li, Hong-Mei; Qin, De-Huai; Wu, Chun
2018-04-01
Huanshao capsule is widely used in irregular menstruation and has achieved a good effect. Huanshao capsule can promote gonad development in mice, significantly improve the ovarian index in mice, increase estrogen level and reduce FSH level in rats, inhibit the pain response induced by oxytocin and estrogen, inhibit writhing reaction induced by acetic acid pain in mice. Due to the complexity of traditional Chinese medical formula, the pharmacological mechanism of the treatment on the irregular menstruation of the Huanshao capsule is unclear. In this study, the internet-based computation platform (www.tcmip.cn)was used to explore the molecular mechanism of Huanshao capsule on the menstrual. The aim of this study was to find the molecular mechanism of Huanshao capsule in treating menstrual. In the study of the molecular mechanism of Huanshao capsule in the treatment of menstrual by using the internet-based computation platform, Huanshao capsule maybe treat the menstrual by the pathway of endocrine system, GnRH signal transduction pathway, estrogen signal transduction pathway, oxytocin signaling pathway, thyroid hormone signaling pathway, VEGF signaling pathway, FCεRI signaling pathway and purine metabolism and nucleotide metabolism. The early pharmacological study confirmed Huanshao capsule could increase the serum estradiol level and decrease follicle stimulating hormone level and the traditional Chinese medicine pharmacology coincide with the prediction result of internet-based computation platform which roles as the pathway of GnRH signaling pathway and estrogen signal transduction pathway. Other pathway needs further experimental verification. Copyright© by the Chinese Pharmaceutical Association.
Posterior capsule opacification.
Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C
2009-02-01
Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.
Ohta, Hidetoshi; Katsuki, Shinichi
2014-01-01
Ever since capsule endoscopy (CE) was introduced into clinical practice, we gastroenterologists have been dreaming of using this less invasive modality to explore the entire gastrointestinal (GI) tract. To realize this dream, we have developed a magnetic navigation system which includes real-time internet streaming of endoscopic video and some useful gadgets (position detection by means of magnetic impedance (MI) sensors and a modified capsule that is "weightless" in water). The design of the weightless capsule made it possible with 0.5T (Tesla) extracorporeal magnets to control the capsule beyond 20cm. A pair of MI sensors on the body surface could detect subtle magnetic flux generated by an intra-capsular magnet in the GI tract by utilizing the space diversity effect which eliminated the interference of terrestrial magnetism. Subjects underwent CE, during which they were free from confinement in the hospital, except for 1 hour when the capsule was manipulated in the stomach and colon. This study had a completion rate of 97.5%. The high completion rate indicates that our system (single capsule endoscopy-SCE) with further improvements could become a viable modality for screening of the entire GI tract.
NASA Astrophysics Data System (ADS)
Correia, Clara R.; Pirraco, Rogério P.; Cerqueira, Mariana T.; Marques, Alexandra P.; Reis, Rui L.; Mano, João F.
2016-02-01
A new concept of semipermeable reservoirs containing co-cultures of cells and supporting microparticles is presented, inspired by the multi-phenotypic cellular environment of bone. Based on the deconstruction of the “stem cell niche”, the developed capsules are designed to drive a self-regulated osteogenesis. PLLA microparticles functionalized with collagen I, and a co-culture of adipose stem (ASCs) and endothelial (ECs) cells are immobilized in spherical liquified capsules. The capsules are coated with multilayers of poly(L-lysine), alginate, and chitosan nano-assembled through layer-by-layer. Capsules encapsulating ASCs alone or in a co-culture with ECs are cultured in endothelial medium with or without osteogenic differentiation factors. Results show that osteogenesis is enhanced by the co-encapsulation, which occurs even in the absence of differentiation factors. These findings are supported by an increased ALP activity and matrix mineralization, osteopontin detection, and the up regulation of BMP-2, RUNX2 and BSP. The liquified co-capsules also act as a VEGF and BMP-2 cytokines release system. The proposed liquified capsules might be a valuable injectable self-regulated system for bone regeneration employing highly translational cell sources.
Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S
2010-01-01
The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of the capsules took much longer time (7 weeks) for ranking the predicted capsule deformation at 40 degrees C. Asides from the time savings, activity determination can be considered to be material sparing by offering capsule-fill compatibility assessment even without the need for preparing liquid-filled capsules once appropriate positive and negative references are established. With further optimization, this approach should enable high throughput screening of LBDDS for capsule-fill compatibility in liquid-filled capsule development.
Mohammadi, Ali Akbar; Jazayeri, Shima; Khosravi-Darani, Kianoush; Solati, Zahra; Mohammadpour, Nakisa; Asemi, Zatollah; Adab, Zohre; Djalali, Mahmoud; Tehrani-Doost, Mehdi; Hosseini, Mostafa; Eghtesadi, Shahryar
2016-11-01
The aim of this study was to determine effects of probiotic yogurt and multispecies probiotic capsule supplementation on mental health and hypothalamic-pituitary-adrenal axis in petrochemical workers. The present randomized double-blind, placebo-controlled trial was conducted on 70 petrochemical workers. Subjects were randomly divided into three groups to receive 100 g/day probiotic yogurt + one placebo capsule (n = 25) or one probiotic capsule daily + 100 g/day conventional yogurt (n = 25) or 100 g/day conventional yogurt + one placebo capsule (n = 20) for 6 weeks. Mental health parameters including general health questionnaire (GHQ) and depression anxiety and stress scale (DASS) scores were measured. Fasting blood samples were obtained at the beginning and 6 weeks after the intervention to quantify hypothalamic-pituitary-adrenal axis. After 6 weeks of intervention, a significant improvement of GHQ was observed in the probiotic yogurt (18.0 ± 1.5 vs. 13.5 ± 1.9, P = 0.007) and in the probiotic capsule group (16.9 ± 1.8 vs. 9.8 ± 1.9, P = 0.001), as well as a significant improvement in DASS scores in the probiotic yogurt (23.3 ± 3.7 vs. 13.0 ± 3.7, P = 0.02) and the probiotic capsule group (18.9 ± 3.2 vs. 9.4 ± 4.0, P = 0.006). However, there was no significant improvement in the conventional yogurt group (P = 0.05 for GHQ and P = 0.08 for DASS). The consumption of probiotic yogurt or a multispecies probiotic capsule had beneficial effects on mental health parameters in petrochemical workers.
Haines, Brian M.; Aldrich, C. H.; Campbell, J. M.; ...
2017-04-24
In this study, we present the results of high-resolution simulations of the implosion of high-convergence layered indirect-drive inertial confinement fusion capsules of the type fielded on the National Ignition Facility using the xRAGE radiation-hydrodynamics code. In order to evaluate the suitability of xRAGE to model such experiments, we benchmark simulation results against available experimental data, including shock-timing, shock-velocity, and shell trajectory data, as well as hydrodynamic instability growth rates. We discuss the code improvements that were necessary in order to achieve favorable comparisons with these data. Due to its use of adaptive mesh refinement and Eulerian hydrodynamics, xRAGE is particularlymore » well suited for high-resolution study of multi-scale engineering features such as the capsule support tent and fill tube, which are known to impact the performance of high-convergence capsule implosions. High-resolution two-dimensional (2D) simulations including accurate and well-resolved models for the capsule fill tube, support tent, drive asymmetry, and capsule surface roughness are presented. These asymmetry seeds are isolated in order to study their relative importance and the resolution of the simulations enables the observation of details that have not been previously reported. We analyze simulation results to determine how the different asymmetries affect hotspot reactivity, confinement, and confinement time and how these combine to degrade yield. Yield degradation associated with the tent occurs largely through decreased reactivity due to the escape of hot fuel mass from the hotspot. Drive asymmetries and the fill tube, however, degrade yield primarily via burn truncation, as associated instability growth accelerates the disassembly of the hotspot. Finally, modeling all of these asymmetries together in 2D leads to improved agreement with experiment but falls short of explaining the experimentally observed yield degradation, consistent with previous 2D simulations of such capsules.« less
Zhou, Quan; Tao, Jing; Song, Huamei; Chen, Aihua; Yang, Huaijie; Zuo, Manzhen; Li, Hairong
2016-12-01
Kuntai capsule has been widely used for the treatment of menopausal syndrome in China for long time. We conducted this review to assess efficacy and safety of Kuntai capsule for the treatment of menopausal syndrome. We searched studies in PubMed, ClinicalTrials, the Cochrane Library, China National Knowledge Infrastructure Database(CNKI), China Science and Technology Journal Database (VIP), Wan fang Database and Chinese Biomedical Literature Database(CBM) until November 20, 2014. Randomized trials on Kuntai capsule for menopausal syndrome, compared with placebo or hormone replacement therapy (HRT) were included. Two reviewers independently retrieved the randomized controlled trials (RCTs) and extracted the information. The Cochrane risk of bias method was used to assess the quality of the included studies, and a Meta-analysis was conducted with Review Manager 5.2 software. A total of 17 RCTs (1455 participants) were included. The studies were of low methodological quality. Meta-analysis indicated that there was no statistical difference in the Kupperman index (KI) [WMD=0.51, 95% CI (-0.04, 1.06)], the effective rate of KI [OR=1.21, 95% CI (0.72, 2.04)], E2 level [WMD=-15.18, 95% CI (-33.93, 3.56)], and FSH level [WMD=-3.46, 95% CI (-7.2, 0.28)] after treatment between Kuntai versus HRT group (P>0.05). However, Compared with HRT, Kuntai capsule could significantly reduce the total incidence of adverse events [OR=0.28, 95% CI (0.17, 0.45)]. Kuntai capsule may be effective for treating menopausal syndrome and lower risk of side effects. The studies we analyzed were of low methodological quality. Therefore, more strictly designed large-scale randomized clinical trials are needed to evaluate the efficacy of Kuntai capsule in menopausal syndrome. Copyright © 2016 Elsevier Ltd. All rights reserved.
2009-01-01
Background The Lactic Acid Bacteria (LAB) are important components of the healthy gut flora and have been used extensively as probiotics. Understanding the cultivable diversity of LAB before and after probiotic administration, and being able to track the fate of administered probiotic isolates during feeding are important parameters to consider in the design of clinical trials to assess probiotic efficacy. Several methods may be used to identify bacteria at the strain level, however, PCR-based methods such as Random Amplified Polymorphic DNA (RAPD) are particularly suited to rapid analysis. We examined the cultivable diversity of LAB in the human gut before and after feeding with two Lactobacillus strains, and also tracked the fate of these two administered strains using a RAPD technique. Results A RAPD typing scheme was developed to genetically type LAB isolates from a wide range of species, and optimised for direct application to bacterial colony growth. A high-throughput strategy for fingerprinting the cultivable diversity of human faeces was developed and used to determine: (i) the initial cultivable LAB strain diversity in the human gut, and (ii) the fate of two Lactobacillus strains (Lactobacillus salivarius NCIMB 30211 and Lactobacillus acidophilus NCIMB 30156) contained within a capsule that was administered in a small-scale human feeding study. The L. salivarius strain was not cultivated from the faeces of any of the 12 volunteers prior to capsule administration, but appeared post-feeding in four. Strains matching the L. acidophilus NCIMB 30156 feeding strain were found in the faeces of three volunteers prior to consumption; after taking the Lactobacillus capsule, 10 of the 12 volunteers were culture positive for this strain. The appearance of both Lactobacillus strains during capsule consumption was statistically significant (p < 0.05). Conclusion We have shown that genetic strain typing of the cultivable human gut microbiota can be evaluated using a high throughput RAPD technique based on single bacterial colonies. Validation of this strategy paves the way for future systematic studies on the fate and efficacy of bacterial probiotics during human clinical trials. PMID:19968877
Unsteady Pressures on a Generic Capsule Shape
NASA Technical Reports Server (NTRS)
Burnside, Nathan; Ross, James C.
2015-01-01
While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.
[Review of the active locomotion system for capsule endoscope].
Zhao, Dechun; Guo, Yijun; Peng, Chenglin
2010-02-01
This review summarized the progress of researches on the active locomotion system for capsule endoscope, analyzed the moving and controlling principles in different locomotion systems, and compared their merits and shortcomings. Owing to the complexity of human intestines and the limits to the size and consumption of locomotion system from the capsule endoscope, there is not yet one kind of active locomotion system currently used in clinical practice. The locomotive system driven by an outer rotational magnetic field could improve the commercial endoscope capsule, while its magnetic field controlling moving is complex. Active locomotion system driven by shape memory alloys will be the orientated development and the point of research in the future.
Antiobesity effects of Undaria lipid capsules prepared with scallop phospholipids.
Okada, Tomoko; Mizuno, Yasuyuki; Sibayama, Shinichi; Hosokawa, Masashi; Miyashita, Kazuo
2011-01-01
Based on previous research findings, a capsule was developed containing n-3 polyunsaturated fatty acid rich scallop phospholipids (PLs) with an incorporation of brown seaweed (Undaria pinnatifida) lipids (ULs) containing fucoxanthin. The antiobesity effects of the capsules were evaluated with an animal model using 3-wk-old male KK-A(y) mice. Each group received different combinations of lipid (UL, PL, UL + PL, or UL + PL capsule) either incorporated into the diet or into drinking water. Animals were sacrificed after a 4-wk experimental feeding period, and adipose tissues and organs were dissected and weighed. Blood samples were obtained to determine plasma lipid profiles. Uncoupling protein 1 (UCP1) mRNA expression levels were determined by real-time polymerase chain reaction analysis, and UCP1 expression was determined by western blotting analysis. Treatment with either UL alone or UL + PL (capsule) through drinking water resulted in a significant reduction in body weight, compared to the control group. The total white adipose tissue weight of mice fed the UL + PL capsule in drinking water was significantly reduced. Both UCP1 and UCP1 mRNA expression in epididymal fat from mice fed the capsule were significantly higher than in the control group. These results suggest that incorporation of UL into scallop-derived PL by means of capsulation may lead to an additive increase in the antiobesity properties of these bioactive lipids.
Developing Soil Models for Dynamic Impact Simulations
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Lyle, Karen H.; Jackson, Karen E.
2009-01-01
This paper describes fundamental soils characterization work performed at NASA Langley Research Center in support of the Subsonic Rotary Wing (SRW) Aeronautics Program and the Orion Landing System (LS) Advanced Development Program (ADP). LS-DYNA(Registered TradeMark)1 soil impact model development and test-analysis correlation results are presented for: (1) a 38-ft/s vertical drop test of a composite fuselage section, outfitted with four blocks of deployable energy absorbers (DEA), onto sand, and (2) a series of impact tests of a 1/2-scale geometric boilerplate Orion capsule onto soil. In addition, the paper will discuss LS-DYNA contact analysis at the soil/structure interface, methods used to estimate frictional forces, and the sensitivity of the model to density, moisture, and compaction.
Solvent-based self-healing approaches for fiber-reinforced composites
NASA Astrophysics Data System (ADS)
Jones, Amanda R.
Damage in composite materials spans many length scales and is often difficult to detect or costly to repair. The incorporation of self-healing functionality in composite materials has the potential to greatly extend material lifetime and reliability. Although there has been remarkable progress in self-healing polymers over the past decade, self-repair in fiber-reinforced composite materials presents significant technical challenges due to stringent manufacturing and performance requirements. For high performance, fiber-reinforced composites, the self-healing components need to survive high temperature processing, reside in matrix interstitial regions to retain a high fiber volume fraction, and have minimal impact on the mechanical properties of the host material. This dissertation explores several microencapsulated solvent-based self-healing approaches for fiber-reinforced composites at the fiber/ matrix interface size scale as well as matrix cracking. Systems are initially developed for room temperature cured epoxies/ glass fiber interfaces and successfully transitioned to carbon fibers and high temperature-cured, thermoplastic-toughened matrices. Full recovery of interfacial bond strength after complete fiber/matrix debonding is achieved with a microencapsulated solvent-based healing chemistry. The surface of a glass fiber is functionalized with microcapsules containing varying concentrations of reactive epoxy resin and ethyl phenyl acetate (EPA) solvent. Microbond specimens consisting of a single fiber and a microdroplet of epoxy are cured at 35°C, tested, and the interfacial shear strengths (IFSS) during the initial (virgin) debonding and subsequent healing events are measured. Debonding of the fiber/matrix interface ruptures the capsules, releasing resin and solvent into the crack plane. The solvent swells the matrix, initiating transport of residual amine functionality for further curing with the epoxy resin delivered to the crack plane. Using a resin-solvent ratio of 3:97, a maximum of 100% IFSS recovery is achieved-- a significant enhancement over prior work that reported 44% average recovery of IFSS with microencapsulated dicyclopentadiene (DCPD) monomer and Grubbs' 1st Generation catalyst healing agents. The effects of capsule coverage, resin-solvent ratio, and capsule size on recovery of IFSS are also determined, providing guidelines for integration of this healing system into high fiber volume fraction structural composites. High healing efficiencies are achieved with capsules as small as 0.6 mum average diameter. The resin-solvent healing system is then extended to repair of a carbon fiber/epoxy interfacial bond. A binder is necessary to improve the retention of capsules on the carbon fiber surface. Two different methods for applying a binder to a carbon fiber surface are investigated. Healing efficiency is assessed by recovery of IFSS of a single functionalized fiber embedded in an epoxy microbond specimen. The two binder protocols produce comparable results, both yielding higher recovery of IFSS than samples prepared without a binder. A maximum of 91% recovery of IFSS is achieved. In the next study, the resin-solvent healing system is applied to both interfacial damage and matrix cracking in a model composite specimen, consisting of discrete fiber tows embedded in a room temperature cured epoxy. Glass fiber tows are precisely placed in a compact tension specimen for controlled crack growth. The progression of matrix cracking and fiber debonding is observed optically during testing. Healing potential is assessed by injection of the healing agents into reference specimens (no capsules). The area under the load-displacement curve recovered during the healing event serves as a metric for evaluation of healing performance. Though full recovery is achieved in neat epoxy specimens, healing efficiency in multi-tow specimens is limited to 50%, due to the larger crack separations and energy lost during fiber fracture. In the case of only a singular embedded fiber tow, healing efficiency increases to an average of 83% recovery with full recovery in several samples. Additionally, microcapsules are incorporated into the compact tension specimen and along the fiber tow interface to evaluate in situ healing. Several strategies to improve microcapsule thermal stability are investigated in order to transition solvent-based healing to high temperature cured material systems. A double shell wall technique is adopted for several different size scales of microcapsules. First, the effect of the inner polyurethane (PU) shell wall thickness on thermal stability is evaluated. Though high thermal stability at 180°C is achieved for large (ca. 150 mum in diameter) capsules, smaller capsules (> 2 mum in diameter) suffer from increased core loss. The addition of certain core thickeners improves thermal stability for small capsules (ca. 20% increase in core retention) when compared to capsules with solvent alone. However, an additional poly(dopamine) coating leads to the greatest improvement in thermal stability, with nearly full retention of the core solvent for all capsule size scales. Finally, a thermoplastic resin poly(bisphenol A-co-epichlorohydrin), PBAE, is blended with a high glass transition temperature (Tg) epoxy matrix to simultaneously toughen and act as a healing agent in combination with encapsulated solvents. Microcapsules are coated with poly(dopamine) to improve the thermal stability and retain the core solvent during a cure cycle at 180°C. The fracture toughness of the high Tg epoxy (EPON 828: diamino diphenyl sulfone) is doubled by the addition of 20 wt % PBAE alone and tripled by the addition of both microcapsules and the thermoplastic phase. Self-healing is achieved with up to 57% recovery of fracture toughness of the toughened epoxy. Healing performance and fracture toughness of the microcapsule containing material remain stable after aging 30 days. The relative amounts of thermoplastic phase and the presence of solvent-filled microcapsules influence the storage modulus, Tg, and healing performance of the polymer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.
2015-09-01
This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulicsmore » and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.« less
Conceptual design of initial opacity experiments on the national ignition facility
NASA Astrophysics Data System (ADS)
Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.
2017-02-01
Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanz, J.; Betti, R.
A sharp boundary model for the deceleration phase of imploding capsules in inertial confinement fusion, in both direct and indirect drive, has been developed. The model includes heat conduction, local {alpha}-particle energy deposition, and shell compressibility effects. A differential equation for the temporal evolution of the modal amplitude interface is obtained. It is found that the {alpha}-particle energy has a strong influence on the evolution of the low l modes, via the compressibility of the shell. The modes are damped by vorticity convection, fire polishing, and {alpha}-particle energy deposition. The existence of a cutoff l number arises from the highmore » blow of velocity into the hot region (rocket effect) if density gradient scale length effects are taken into account at the interface. The differential equation for the modal amplitude is used as a postprocessor to the results of 1D-SARA code [J. J. Honrubia, J. Quant. Spectrosc. Radiat. Transfer. 49, 491 (1993)] in a typical capsule for indirect-drive ignition designed on the National Ignition Facility. It is found that modes with l>180 are completely stabilized. The results are in agreement with two-dimensional simulations.« less
[Development of a video image system for wireless capsule endoscopes based on DSP].
Yang, Li; Peng, Chenglin; Wu, Huafeng; Zhao, Dechun; Zhang, Jinhua
2008-02-01
A video image recorder to record video picture for wireless capsule endoscopes was designed. TMS320C6211 DSP of Texas Instruments Inc. is the core processor of this system. Images are periodically acquired from Composite Video Broadcast Signal (CVBS) source and scaled by video decoder (SAA7114H). Video data is transported from high speed buffer First-in First-out (FIFO) to Digital Signal Processor (DSP) under the control of Complex Programmable Logic Device (CPLD). This paper adopts JPEG algorithm for image coding, and the compressed data in DSP was stored to Compact Flash (CF) card. TMS320C6211 DSP is mainly used for image compression and data transporting. Fast Discrete Cosine Transform (DCT) algorithm and fast coefficient quantization algorithm are used to accelerate operation speed of DSP and decrease the executing code. At the same time, proper address is assigned for each memory, which has different speed;the memory structure is also optimized. In addition, this system uses plenty of Extended Direct Memory Access (EDMA) to transport and process image data, which results in stable and high performance.
Landing Characteristics of a Reentry Capsule with a Torus-Shaped Air Bag for Load Alleviation
NASA Technical Reports Server (NTRS)
McGehee, John R.; Hathaway, Melvin E.
1960-01-01
An experimental investigation has been made to determine the landing characteristics of a conical-shaped reentry capsule by using torus-shaped air bags for impact-load alleviation. An impact bag was attached below the large end of the capsule to absorb initial impact loads and a second bag was attached around the canister to absorb loads resulting from impact on the canister when the capsule overturned. A 1/6-scale dynamic model of the configuration was tested for nominal flight paths of 60 deg. and 90 deg. (vertical), a range of contact attitudes from -25 deg. to 30 deg., and a vertical contact velocity of 12.25 feet per second. Accelerations were measured along the X-axis (roll) and Z-axis (yaw) by accelerometers rigidly installed at the center of gravity of the model. Actual flight path, contact attitudes, and motions were determined from high-speed motion pictures. Landings were made on concrete and on water. The peak accelerations along the X-axis for landings on concrete were in the order of 3Og for a 0 deg. contact attitude. A horizontal velocity of 7 feet per second, corresponding to a flight path of 60 deg., had very little effect upon the peak accelerations obtained for landings on concrete. For contact attitudes of -25 deg. and 30 deg. the peak accelerations along the Z-axis were about +/- l5g, respectively. The peak accelerations measured for the water landings were about one-third lower than the peak accelerations measured for the landings on concrete. Assuming a rigid body, computations were made by using Newton's second law of motion and the force-stroke characteristics of the air bag to determine accelerations for a flight path of 90 deg. (vertical) and a contact attitude of 0 deg. The computed and experimental peak accelerations and strokes at peak acceleration were in good agreement for the model. The special scaling appears to be applicable for predicting full-scale time and stroke at peak acceleration for a landing on concrete from a 90 deg. flight path at a 0 deg. It appears that the full-scale approximately the same as those obtained from the model for the range of attitudes and flight paths investigated.
Zhang, Zhen-Xin; Hong, Zhen; Wang, Yan-Ping; He, Li; Wang, Ning; Zhao, Zhong-Xin; Zhao, Gang; Shang, Lan; Weisskopf, Marianne; Callegari, Francesca; Strohmaier, Christine
2016-06-01
To compare the once-daily rivastigmine patch 9.5 mg/24 h (10 cm(2) ) versus twice-daily capsule (12 mg/day) in Chinese patients with probable Alzheimer's disease (AD) (mini-mental state examination [MMSE] scores of 10-20). The primary objective was to demonstrate the noninferiority of patch to capsule in Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) change from baseline to 24 week. Secondary endpoints included cognition (MMSE), overall clinical response (Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change [ADCS-CGIC]), activities of daily living (Alzheimer's Disease Cooperative Study-Activities of Daily Living [ADCS-ADL]), behavior (Neuropsychiatric Inventory [NPI-12]), and safety. Similar cognitive improvement was observed in both patch (n = 248) and capsule (n = 253) groups. Statistical noninferiority for ADAS-Cog was not established (least-square means difference, 0.1; 95% confidence interval, -1.2; 1.5). Considering all efficacy parameters into account, both treatments showed similar performance at Week 24. Treatment-related adverse events (AEs) were lower for patch (39.7%) compared with capsule (49.8%). Application site pruritus was reported in 10.9% of patients receiving patch; most cases were mild. Gastrointestinal AEs including nausea, vomiting, and diarrhea occurred less frequently in the patch group (15.8% vs. 28.7%). Rivastigmine patch 9.5 mg/24 h is effective and well tolerated in Chinese patients with probable AD. © 2016 John Wiley & Sons Ltd.
Arefin, Md Shamsul; Redoute, Jean-Michel; Yuce, Mehmet Rasit
2018-01-01
This paper presents a wireless capsule microsystem to detect and monitor the pH, pressure, and temperature of the gastrointestinal tract in real time. This research contributes to the integration of sensors (microfabricated capacitive pH, capacitive pressure, and resistive temperature sensors), frequency modulation and pulse width modulation based interface IC circuits, microcontroller, and transceiver with meandered conformal antenna for the development of a capsule system. The challenges associated with the system miniaturization, higher sensitivity and resolution of sensors, and lower power consumption of interface circuits are addressed. The layout, PCB design, and packaging of a miniaturized wireless capsule, having diameter of 13 mm and length of 28 mm, have successfully been implemented. A data receiver and recorder system is also designed to receive physiological data from the wireless capsule and to send it to a computer for real-time display and recording. Experiments are performed in vitro using a stomach model and minced pork as tissue simulating material. The real-time measurements also validate the suitability of sensors, interface circuits, and meandered antenna for wireless capsule applications.
Development of Naphthalene PLIF for Visualizing Ablation Products From a Space Capsule Heat Shield
NASA Technical Reports Server (NTRS)
Combs, C. S.; Clemens, N. T.; Danehy, P. M.
2014-01-01
The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield. To better design this heat shield and others that will undergo planetary entry, an improved understanding of the ablation process would be beneficial. Here, a technique developed at The University of Texas at Austin that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to enable visualization of the ablation products in a hypersonic flow is applied. Although high-temperature ablation is difficult and expensive to recreate in a laboratory environment, low-temperature sublimation creates a limited physics problem that can be used to explore ablation-product transport in a hypersonic flow-field. In the current work, a subscale capsule reentry vehicle model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel. The PLIF technique provides images of the spatial distribution of sublimated naphthalene in the heat-shield boundary layer, separated shear layer, and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. PLIF images have shown high concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure. It was shown that, in general, the capsule shear layer appears to be more unsteady at lower angels of attack. The PLIF images demonstrated that during a wind tunnel run, as the model heated up, the rate of naphthalene ablation increased, since the PLIF signal increased steadily over the course of a run. Additionally, the shear layer became increasingly unsteady over the course of a wind tunnel run, likely because of increased surface roughness but also possibly because of the increased blowing. Regions with a relatively low concentration of naphthalene were also identified in the capsule backshell recirculation region and are most likely the result of cross-flow-induced vortices on the capsule afterbody.
Gelman, Dale B.; Gerling, Dan; Blackburn, Michael A.
2005-01-01
It has been reported that the aphelinid wasp Eertmocerus mundus parasitizes all four nymphal instars of the sweet potato whitefly, Bemisia tabaci (Biotype B), with 3rd instars being the preferred hosts. The parasitoid lays its egg on the leaf underneath the host nymph. First instars hatch and later penetrate the whitefly. Previous studies have shown that the initiation of parasitoid penetration induces the host to form a cellular capsule around the parasitoid. As described here, females never oviposited once the 4th instar whitefly nymph had initiated adult development. First instar E. mundus larvae were observed under 2nd, 3rd and 4th instar whitefly nymphs, however, penetration did not occur until the whitefly had reached the 4th instar. The non-penetrating E. mundus larva almost always induced permanent developmental arrest in its 4th instar whitefly host and also caused a reduction in whole body host ecdysteroid titers. Therefore, unless there is a peak in molting hormone titer in the area local to penetration, it appears that the induction of capsule formation is not due to an increase in ecdysteroid titer. As the capsule formed around the penetrating parasitoid, host epidermal cells multiplied and became cuboidal and columnar, and relatively thick layers of new cuticle were deposited within the developing capsule, particularly near its ventral opening. The newly formed host cuticle was thinner in the dorsal part of the capsule and appeared to be absent at its apex. These results provide new information regarding the timing and dynamics of parasitoid oviposition and egg hatch as related to larval penetration, parasitoid-induced changes in whitefly development, molting hormone titers and the process of capsule formation. PMID:17119628
An ultra-low-power image compressor for capsule endoscope.
Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo
2006-02-25
Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.
Redox-controlled molecular permeability of composite-wall microcapsules
NASA Astrophysics Data System (ADS)
Ma, Yujie; Dong, Wen-Fei; Hempenius, Mark A.; Möhwald, Helmuth; Julius Vancso, G.
2006-09-01
Many smart materials in bioengineering, nanotechnology and medicine allow the storage and release of encapsulated drugs on demand at a specific location by an external stimulus. Owing to their versatility in material selection, polyelectrolyte multilayers are very promising systems in the development of microencapsulation technologies with permeation control governed by variations in the environmental conditions. Here, organometallic polyelectrolyte multilayer capsules, composed of polyanions and polycations of poly(ferrocenylsilane) (PFS), are introduced. Their preparation involved layer-by-layer self-assembly onto colloidal templates followed by core removal. PFS polyelectrolytes feature redox-active ferrocene units in the main chain. Incorporation of PFS into the capsule walls allowed us to explore the effects of a new stimulus, that is, changing the redox state, on capsule wall permeability. The permeability of these capsules could be sensitively tuned via chemical oxidation, resulting in a fast capsule expansion accompanied by a drastic permeability increase in response to a very small trigger. The substantial swelling could be suppressed by the application of an additional coating bearing common redox-inert species of poly(styrene sulfonate) (PSS-) and poly(allylamine hydrochloride) (PAH+) on the outer wall of the capsules. Hence, we obtained a unique capsule system with redox-controlled permeability and swellability with a high application potential in materials as well as in bioscience.
A review of drug delivery systems for capsule endoscopy.
Munoz, Fredy; Alici, Gursel; Li, Weihua
2014-05-01
The development of a highly controllable drug delivery system (DDS) for capsule endoscopy has become an important field of research due to its promising applications in therapeutic treatment of diseases in the gastrointestinal (GI) tract and drug absorption studies. Several factors need to be considered to establish the minimum requirements for a functional DDS. Environmental factors of the GI tract and also pharmaceutical factors can help determine the requirements to be met by a DDS in an endoscopic capsule. In order to minimize the influence of such factors on the performance of an effective DDS, at least two mechanisms should be incorporated into a capsule endoscope: an anchoring mechanism to control the capsule position and a drug release mechanism to control variables such as the drug release rate, number of doses and amount of drug released. The implementation of such remotely actuated mechanisms is challenging due to several constraints, including the limited space available in a swallowable capsule endoscope and the delicate and complex environment within the GI tract. This paper presents a comprehensive overview of existing DDS. A comparison of such DDS for capsule endoscopy based on the minimum DDS requirements is presented and future work is also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Stadlbauer, Vanessa; Lang-Olip, Ingrid; Leber, Bettina; Mayrhauser, Ursula; Koestenbauer, Sonja; Tawdrous, Monika; Moche, Michael; Sereinigg, Michael; Seider, Daniel; Iberer, Florian; Wiederstein-Grasser, Iris; Portugaller, Rupert Horst; Stiegler, Philipp
2016-01-01
Radiofrequency ablation (RFA) is a minimal invasive therapeutic option for patients with hepatocellular carcinoma or liver metastases. We investigated RFA-induced cellular changes in the liver of pigs. Healthy pigs (n=18) were sacrificed between day 0 and 3 months after RFA. The wound healing process was evaluated by computed tomography (CT), chromotrope anilinblue (CAB) staining of large-scale and standard tissue sections. Immunohistochemistry (IHC) for heat shock protein 70, Caspase-3, Ki67, Reelin, Vinculin, Vimentin and α-SMA was perfomed. One day after RFA, CAB staining showed cell damage and massive hyperaemia. All IHC markers were predominantly expressed at the outer borders of the lesion, except Reelin, which was mainly detected in untreated liver regions. By staining for Hsp70, the heat stress during RFA was monitored, which was most distinct 1-2 days after RFA. CT revealed decreased lesion size after one week. Development of a Vimentin and α-SMA positive fibrotic capsule was observed. In the early phase signs of cell damage, apoptosis and proliferation are dominant. Reduced expression of Reelin suggests a minor role of hepatic stellate cells in the RFA zone. After one week myofibroblasts become prominent and contribute to the development of the fibrotic capsule. This elucidates the pathophysiology of RFA and could contribute to the future optimization of RFA procedures.
ERIC Educational Resources Information Center
Rose, Jessica; Mirmiran, Majid; Butler, Erin E.; Lin, Cindy Y.; Barnes, Patrick D.; Kermoian, Rosanne; Stevenson, David K.
2007-01-01
Neonatal microstructural development in the posterior limbs of the internal capsule (PLIC) was assessed using diffusion tensor imaging (DTI) fractional anisotropy (FA) in 24 very-low-birthweight preterm infants at 37 weeks' gestational age and compared with the children's gait and motor deficits at 4 years of age. There were 14 participants with…
Steagall, Paulo V; Benito, Javier; Monteiro, Beatriz P; Doodnaught, Graeme M; Beauchamp, Guy; Evangelista, Marina C
2017-09-01
Objectives The aim of the study was to evaluate the analgesic efficacy of gabapentin-buprenorphine in comparison with meloxicam-buprenorphine or buprenorphine alone, and the correlation between two pain-scoring systems in cats. Methods Fifty-two adult cats were included in a randomized, controlled, blinded study. Anesthetic protocol included acepromazine-buprenorphine-propofol-isoflurane. The gabapentin-buprenorphine group (GBG, n = 19) received gabapentin capsules (50 mg PO) and buprenorphine (0.02 mg/kg IM). The meloxicam-buprenorphine group (MBG, n = 15) received meloxicam (0.2 mg/kg SC), buprenorphine and placebo capsules (PO). The buprenorphine group (BG, n = 18) received buprenorphine and placebo capsules (PO). Gabapentin (GBG) and placebo (MBG and BG) capsules were administered 12 h and 1 h before surgery. Postoperative pain was evaluated up to 8 h after ovariohysterectomy using a multidimensional composite pain scale (MCPS) and the Glasgow pain scale (rCMPS-F). A dynamic interactive visual analog scale (DIVAS) was used to evaluate sedation. Rescue analgesia included buprenorphine and/or meloxicam if the MCPS ⩾6. A repeated measures linear model was used for statistical analysis ( P <0.05). Spearman's rank correlation between the MCPS and rCMPS-F was evaluated. Results The prevalence of rescue analgesia with a MCPS was not different ( P = 0.08; GBG, n = 5 [26%]; MBG, n = 2 [13%]; BG, n = 9 [50%]), but it would have been significantly higher in the BG (n = 14 [78%]) than GBG ( P = 0.003; n = 5 [26%]) and MBG ( P = 0.005; n = 4 [27%]) if intervention was based on the rCMPS-F. DIVAS and MCPS/rCMPS-F scores were not different among treatments. A strong correlation was observed between scoring systems ( P <0.0001). Conclusions and relevance Analgesia was not significantly different among treatments using an MCPS. Despite a strong correlation between scoring systems, GBG/MBG would have been superior to the BG with the rCMPS-F demonstrating a potential type II error with an MCPS due to small sample size.
Development of a biologically inspired locomotion system for a capsule endoscope.
Hosokawa, Daisuke; Ishikawa, Takuji; Morikawa, Hirohisa; Imai, Yohsuke; Yamaguchi, Takami
2009-12-01
A capsule endoscope has a limited ability to obtain images of the digestive organs because its movement depends on peristaltic motion. To overcome this problem, capsule endoscopes require a propulsion system. This paper proposes a propulsion system for a capsule endoscope that mimics the locomotive mechanism of snails and earthworms. The prototype crawler can elongate and contract itself longitudinally and adhere to a wall via suction cups. We investigated the effect of the inclination angle of the propulsion plane, the mucus viscosity between the propulsion plane and the crawler, and the stiffness of the propulsion plane on the locomotion of the prototype crawler. We found that the crawler could move on a rubber sheet and on inclined planes covered with mucus. We discussed advantages and limitations of the prototype crawler compared to the different locomotive systems developed in former studies. We believe that the prototype crawler provides a better understanding of the propulsion mechanism for use in the gastrointestinal tract. Copyright (c) 2009 John Wiley & Sons, Ltd.
Alginate Encapsulation of Pluripotent Stem Cells Using a Co-axial Nozzle
Horiguchi, Ikki; Sakai, Yasuyuki
2015-01-01
Pluripotent stem cells (PS cells) are the focus of intense research due to their role in regenerative medicine and drug screening. However, the development of a mass culture system would be required for using PS cells in these applications. Suspension culture is one promising culture method for the mass production of PS cells, although some issues such as controlling aggregation and limiting shear stress from the culture medium are still unsolved. In order to solve these problems, we developed a method of calcium alginate (Alg-Ca) encapsulation using a co-axial nozzle. This method can control the size of the capsules easily by co-flowing N2 gas. The controllable capsule diameter must be larger than 500 µm because too high a flow rate of N2 gas causes the breakdown of droplets and thus heterogeneous-sized capsules. Moreover, a low concentration of Alg-Na and CaCl2 causes non-spherical capsules. Although an Alg-Ca capsule without a coating of Alg-PLL easily dissolves enabling the collection of cells, they can also potentially leak out from capsules lacking an Alg-PLL coating. Indeed, an alginate-PLL coating can prevent cellular leakage but is also hard to break. This technology can be used to research the stem cell niche as well as the mass production of PS cells because encapsulation can modify the micro-environment surrounding cells including the extracellular matrix and the concentration of secreted factors. PMID:26168084
Feng, Dan-dan; Tang, Tao; Lin, Xiang-ping; Yang, Zhao-yu; Yang, Shu; Xia, Zi-an; Wang, Yun; Zheng, Piao; Wang, Yang; Zhang, Chun-hu
2016-01-01
Depression is a major mental disorder, and is currently recognized as the second-leading cause of disability worldwide. However, the therapeutic effect of antidepressants remains unsatisfactory. For centuries, Chinese herbal formulas (CHFs) have been widely used in the treatment of depression, achieving better therapeutic effects than placebo and having fewer side effects than conventional antidepressants. Here, we review the ethnopharmacology, phytochemistry, and pharmacology studies of nine common CHFs: “banxia houpo” decoction, “chaihu shugansan”, “ganmaidazao” decoction, “kaixinsan”, “shuganjieyu” capsules, “sinisan”, “wuling” capsules, “xiaoyaosan”, and “yueju”. Eight clinical trials and seven meta-analyses have supported the theory that CHFs are effective treatments for depression, decreasing Hamilton Depression Scale scores and showing few adverse effects. Evidence from 75 preclinical studies has also elucidated the multitarget and multipathway mechanisms underlying the antidepressant effect of the nine CHFs. Decoctions, capsules, and pills all showed antidepressant effects, ranked in descending order of efficacy. According to traditional Chinese medicine theory, these CHFs have flexible compatibility and mainly act by soothing the liver and relieving depression. This review highlights the effective treatment choices and candidate compounds for patients, practitioners, and researchers in the field of traditional Chinese medicine. In summary, the current evidence supports the efficacy of CHFs in the treatment of depression, but additional large-scale randomized controlled clinical trials and sophisticated pharmacology studies should be performed. PMID:27703356
Factors influencing the adequacy of microencapsulation of rat pancreatic islets.
De Vos, P; De Haan, B; Wolters, G H; Van Schilfgaarde, R
1996-10-15
The observation that only a portion of all alginate-polylysine microcapsules are overgrown after implantation suggests that physical imperfections of individual capsules, rather than the chemical composition of the material applied, are responsible for inducing insufficient biocompatibility and thereby fibrotic overgrowth of those capsules. We recently developed a lectin binding assay that allows for quantifying the portion of inadequately encapsulated islets, and demonstrated that inadequately encapsulated islets induce a fibrotic response associated with graft failure. The present study investigates factors influencing the adequacy of encapsulation of pancreatic islets. We applied our lectin binding assay and found that the number of inadequate, and particularly incomplete, capsules is influenced by the following factors. (1) A capsule diameter of 800 micrometers is associated with a lower percentage of inadequate capsules than smaller (500 micrometers and 600 micrometers) or larger (1800 micrometers) capsules. (2) A high rather than low guluronic acid content of the alginate is associated with a lower percentage of inadequate capsules. This can be explained, at least in part, by smaller ranges of swelling and subsequent shrinkage during the encapsulation procedure. (3) An increase in viscosity caused by applying a higher alginate concentration compensates for a low guluronic acid content. This effect of increased viscosity cannot be explained by a reduced range of swelling and shrinkage during the encapsulation procedure. We conclude that alginates with a high guluronic acid content and a viscosity near the filtration limit are preferable in order to minimize the number of inadequate capsules.
Efanov, J I; Giot, J P; Fernandez, J; Danino, M A
2017-06-01
Macro-texturing of breast implants was developed with the double goal of improving implant stabilization within the breast cavity and decreasing the rate of capsular contractures. However, recent evidence suggests that double capsular formation, a potentially worrisome phenomenon associated with late seromas and biofilms, occurs with preponderance in macro-textured implants. Our objective was to analyze histologically different regions of double capsules to determine if they are more prone to mechanical movements. A prospective analysis including patients undergoing second-stage expander to definitive breast-implant reconstruction post-mastectomy was conducted after intraoperative identification of the double capsule phenomenon. Two samples were collected from each capsules around the implant, located centrally and laterally. The specimens were sent for histological analysis by the institution's pathologist. In total, 10 patients were identified intraoperatively with partial double capsule phenomenon. Among samples retrieved from the lateral aspect of the breast implant, all were associated with delamination and fractures in the collagen matrix of the double capsules. This phenomenon was not observed in any sample from the dome of the breast. Breast-implant macro-texturing plays an important role on delamination of capsules on lateral portions of the breast, which may have an etiologic role in double capsule formation. Manufacturing implants with macro-texturing on one side and smooth surface on the other could diminish mechanical shear forces responsible for these findings. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
A biodegradable, immunoprotective, dual nanoporous capsule for cell-based therapies.
Zhang, Xulang; He, Hongyan; Yen, Chi; Ho, Wiston; Lee, L James
2008-11-01
To demonstrate the transplantation of drug-secreting cells with immunoprotection, a biodegradable delivery device combining two nanoporous capsules is developed using secretory alkaline phosphatase gene (SEAP) transfected mouse embryonic stem (mES) cells as a model system. The outer capsule is a poly (ethylene glycol) (PEG)-coated poly (epsilon-caprolactone) (PCL) chamber covered with a PEG grafted PCL nanoporous membrane made by phase inversion technique. SEAP gene transfected mES cells encapsulated in alginate-poly-L-lysine (AP) microcapsules are placed in the PCL capsule. Both nanoporous capsules showed good immunoprotection in the IgG solution. In microcapsules, mES cells could form a spheroid embryonic body (EB) and grow close to the microcapsule size. The secreted SEAP from encapsulated mES cells increased gradually to a maximum value before reaching a steady level, following the cell growth pattern in the microcapsule. Without microcapsules, mES cells only formed a monolayer in the large PCL capsule. The secreted SEAP release was very low. The integrated device showed a similar cell growth pattern to that in microcapsules alone, while the SEAP release rate could be regulated by the pore size of the large capsule. This integrated device can achieve multi-functionalities for cell-based therapy, i.e. a 3-D microenvironment provided by microcapsules for cell growth, superior immunoprotection and controllable release performance provided by the two nanoporous membranes, and good fibrosis prevention by PEG surface modification of the large capsule.
Controllable synthesis of single-walled carbon nanotube framework membranes and capsules.
Song, Changsik; Kwon, Taeyun; Han, Jae-Hee; Shandell, Mia; Strano, Michael S
2009-12-01
Controlling the morphology of membrane components at the nanometer scale is central to many next-generation technologies in water purification, gas separation, fuel cell, and nanofiltration applications. Toward this end, we report the covalent assembly of single-walled carbon nanotubes (SWNTs) into three-dimensional framework materials with intertube pores controllable by adjusting the size of organic linker molecules. The frameworks are fashioned into multilayer membranes possessing linker spacings from 1.7 to 3.0 nm, and the resulting framework films were characterized, including transport properties. Nanoindentation measurements by atomic force microscopy show that the spring constant of the SWNT framework film (22.6 +/- 1.2 N/m) increased by a factor of 2 from the control value (10.4 +/- 0.1 N/m). The flux ratio comparison in a membrane-permeation experiment showed that larger spacer sizes resulted in larger pore structures. This synthetic method was equally efficient on silica microspheres, which could then be etched to create all-SWNT framework, hollow capsules approximately 5 mum in diameter. These hollow capsules are permeable to organic and inorganic reagents, allowing one to form inorganic nanoparticles, for example, that become entrapped within the capsule. The ability to encapsulate functional nanomaterials inside perm-selective SWNT cages and membranes may find applications in new adsorbents, novel catalysts, and drug delivery vehicles.
Taavoni, Simin; Ekbatani, Neda Nazem; Haghani, Hamid
2017-03-01
Menopausal symptoms experienced by women vary widely, and while many women transition through menopause with manageable symptoms, others experience severe symptoms, which may impair their quality of life. The purpose of this study was to determine the effect of Tribulus terrestris , ginger, saffron, and Cinnamomum on menopausal symptoms. A randomised, triple-blind, controlled trial design was used for this study. The participants were 80 postmenopausal women aged 50-60 years. A demographic data form and the Menopause Rating Scale were used to collect data. The women were randomly divided into two groups, each of which received either an Aphrodit capsule or a placebo twice a day for four weeks. The two bottles looked exactly the same, so that the investigator and the participants were not aware of the contents of the bottles. Each Aphrodit capsule contained 40 mg of Tribulus terrestris , 12.27 mg of Zingiber officinale , 3 mg of Crocus sativus extract, and 11 mg of Cinnamomum zeylanicum , while the placebo capsules contained 50 mg of starch. Descriptive and inferential statistics were used to analyse the data. A statistically significant change was reported in the menopausal symptoms of the intervention group compared with the placebo group. The results of the study demonstrate that the Aphrodit capsule was effective in reducing menopausal symptoms.
Li, Min; He, Qingyong; Chen, Yinfeng; Li, Bo; Feng, Bo; Zhang, Zhenpeng; Wang, Jie
2015-01-01
Objective. To evaluate the efficacy and safety of Xuezhikang capsule treating type 2 diabetes with hyperlipidemia. Methods. We searched six databases to identify relevant studies published before January 2015. Two review authors independently extracted data and assessed the Cochrane risk of bias tool. We resolved disagreements with this assessment through discussion and a decision was achieved by consensus. Results. We included 21 studies (1548 participants). Treatment courses were at least 8 weeks. Overall, the risk of bias of included trials was unclear. Among them, 16 studies could conduct meta-analysis. The result showed that compared with routine group (5 studies), Xuezhikang group had more effect on decreasing TC, TG, LDL-C, and rising HDL-C. However, compared with statins group (11 studies), Xuezhikang group has less effect on decreasing TC, TG, and rising HDL-C. Meanwhile, two groups had no statistical differences of LDL-C level. Conclusion. Xuezhikang capsule may be effective for treating type 2 diabetes with hyperlipemia. Our findings should be considered cautiously due to unclear risk of bias of the included studies and low methodological quality. Therefore, more strictly designed large-scale randomized clinical trials are needed to evaluate the efficacy of Xuezhikang capsule in type 2 diabetes with hyperlipemia. PMID:26246836
NASA Astrophysics Data System (ADS)
Hall, Gareth; Krauland, Christine; Buscho, Justin; Hibbard, Robin; McCarville, Thomas; Lowe-Webb, Roger; Ayers, Shannon; Kalantar, Daniel; Kohut, Thomas; Kemp, G. Elijah; Bradley, David; Bell, Perry; Landen, Otto; Brewster, Nathaniel; Piston, Kenneth
2017-10-01
The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically-bent crystal imager being developed for the NIF, which will allow ICF capsule implosions to be radiographed close to stagnation for the first time. This has not been possible using the previous pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter in the final stages of the implosion. CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth (a few eV) inherent to imagers based on near-normal-incidence Bragg x-ray optics. The development of a diagnostic with the capability to image the capsule during the final stages of the implosion (r less than 200um) is important, as it will allow the shape, integrity and density of the shell to be measured, and will allow the evolution of features, such as the fill tube and capsule support structure, to be imaged close to bang time. The concept and operation of the 11.6keV CBI diagnostic will be discussed, and the first results from experiments on the NIF will be presented. Prepared by LLNL under Contract DE-AC52-07NA27344.
Bioavailability study of dronabinol oral solution versus dronabinol capsules in healthy volunteers
Parikh, Neha; Kramer, William G; Khurana, Varun; Cognata Smith, Christina; Vetticaden, Santosh
2016-01-01
Background Dronabinol, a pharmaceutical Δ-9-tetrahydrocannabinol, was originally developed as an oral capsule. This study evaluated the bioavailability of a new formulation, dronabinol oral solution, versus a dronabinol capsule formulation. Methods In an open-label, four-period, single-dose, crossover study, healthy volunteers were randomly assigned to one of two treatment sequences (T-R-T-R and R-T-R-T; T = dronabinol 4.25 mg oral solution and R = dronabinol 5 mg capsule) under fasted conditions, with a minimum 7-day washout period between doses. Analyses were performed on venous blood samples drawn 15 minutes to 48 hours postdose, and dronabinol concentrations were assayed by liquid chromatography–tandem mass spectrometry. Results Fifty-one of 52 individuals had pharmacokinetic data for analysis. The 90% confidence interval of the geometric mean ratio (oral solution/capsule) for dronabinol was within the 80%–125% bioequivalence range for area under the plasma concentration–time curve (AUC) from time zero to last measurable concentration (AUC0–t) and AUC from time zero to infinity (AUC0–∞). Maximum plasma concentration was also bioequivalent for the two dronabinol formulations. Intraindividual variability in AUC0–∞ was >60% lower for dronabinol oral solution 4.25 mg versus dronabinol capsule 5 mg. Plasma dronabinol concentrations were detected within 15 minutes postdose in 100% of patients when receiving oral solution and in <25% of patients when receiving capsules. Conclusion Single-dose dronabinol oral solution 4.25 mg was bioequivalent to dronabinol capsule 5 mg under fasted conditions. Dronabinol oral solution formulation may provide an easy-to-swallow administration option with lower intraindividual variability as well as more rapid absorption versus dronabinol capsules. PMID:27785111
Lien, Gi-Shih; Wu, Ming-Shun; Chen, Chun-Nan; Liu, Chih-Wen; Suk, Fat-Moon
2018-04-01
Current capsule endoscopy procedures are ineffective for upper gastrointestinal (GI) tract examination because they do not allow for operator-controlled navigation of the capsule. External controllability of a capsule endoscope with an applied magnetic field is a possible solution to this problem. We developed a novel magnetic-assisted capsule endoscope (MACE) system to visualize the entire upper GI tract. The present study evaluated the safety and feasibility of the MACE system for the examination of the upper GI tract, including the esophagus, stomach, and duodenum. The present open clinical study enrolled ten healthy volunteers. All participants swallowed a MACE, and an external magnetic field navigator was used for magnetic capsule manipulation in the upper GI tract. We assessed the maneuverability of the magnetic capsule and completeness of the MACE examination as well as the safety and tolerability of the procedure. The present study enrolled ten healthy volunteers with a mean age and body mass index of 47.7 years and 25.6 kg/m 2 , respectively. One volunteer withdrew because of difficulty in swallowing the capsule. In total, nine volunteers underwent the MACE examination. The average examination time was 27.1 min. The maneuverability of the capsule was assessed as good and fair in 55.6 and 44.4% of the participants, respectively. The overall completeness of the examination in the esophagus, stomach, and duodenum was 100, 85.2, and 86.1%, respectively. No severe adverse events occurred during this study. All participants exhibited satisfactory tolerance of the MACE examination. The MACE system has satisfactory maneuverability and visualization completeness with excellent acceptance and tolerance.
This technology capsule summarizes the findings of an evaluation of the Unterdruck-Verdampfer-Brunnen (UVB) technology developed by IEG Technologies (IEG) and licensed in the eastern United States by Environmental Laboratories, Inc. (ELI) and SBP Technologies, Inc. (SBP). This e...
"Salmonella arizona" Infections in Latinos Associated with Rattlesnake Folk Medicine.
ERIC Educational Resources Information Center
Waterman, Stephen H.; And Others
1990-01-01
Conducted a case-control study to determine the magnitude of the problem of Latino patients who ingested rattlesnake capsules and then developed serious "Salmonella arizona" infections. Eighty-two percent of infected Latinos in 1986-87 who were questioned reported ingesting snake capsules. Discusses the association of ingesting snake…
Enteric coating of granules containing the probiotic Lactobacillus acidophilus.
Pyar, Hassan; Peh, Kok-Khiang
2014-06-01
In the present study, a capsule formulation composed of enteric coated granules of Lactobacillus acidophilus ATCC 4962 was developed using Eudragit L30D-55 as enteric polymer. Optimization of the capsule formulation was achieved with a maximum viable cell count after 2 h of incubation in acid medium and disintegration time of 1 h in buffer pH 6.8. The amount of Eudragit L30D-55 in the capsules correlated with gastric juice resistance. The best protective qualities against artificial gastric juice were observed when capsules were prepared from granules composed of L. acidophilus, corn starch, lactose monohydrate, polyvinylpyrrolidone and coated with 12.5 % (m/V) of Eudragit L30D-55. Capsule formulation of L. acidophilus in edible broth medium suspension serves as a cheap alternative to the expensive freeze-drying procedure for preparing L. acidophilus. In addition, the enteric coating using Eudragit L30D-55 could protect probiotics from the acidic gastric environment and enhance the bioactivity of probiotics along with replacement of pathogenic microbes in human intestine.
Active multilayered capsules for in vivo bone formation
Facca, S.; Cortez, C.; Mendoza-Palomares, C.; Messadeq, N.; Dierich, A.; Johnston, A. P. R.; Mainard, D.; Voegel, J.-C.; Caruso, F.; Benkirane-Jessel, N.
2010-01-01
Interest in the development of new sources of transplantable materials for the treatment of injury or disease has led to the convergence of tissue engineering with stem cell technology. Bone and joint disorders are expected to benefit from this new technology because of the low self-regenerating capacity of bone matrix secreting cells. Herein, the differentiation of stem cells to bone cells using active multilayered capsules is presented. The capsules are composed of poly-L-glutamic acid and poly-L-lysine with active growth factors embedded into the multilayered film. The bone induction from these active capsules incubated with embryonic stem cells was demonstrated in vitro. Herein, we report the unique demonstration of a multilayered capsule-based delivery system for inducing bone formation in vivo. This strategy is an alternative approach for in vivo bone formation. Strategies using simple chemistry to control complex biological processes would be particularly powerful, as they make production of therapeutic materials simpler and more easily controlled. PMID:20160118
D 2 and D-T Liquid-Layer Target Shots at the National Ignition Facility
Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas; ...
2018-01-19
Experiments at the National Ignition Facility (NIF) using targets containing a deuterium-tritium (D-T) fuel layer have, until recently, required that a high-quality layer of solid D-T (herein referred to as an ice layer) be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of ice layers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam-lined capsule but also changes to the capsule filling processmore » and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. Finally, these changes and the target’s performance during four target shots on NIF are discussed.« less
The Cryptococcus neoformans Capsule: a Sword and a Shield
O'Meara, Teresa R.
2012-01-01
Summary: The human fungal pathogen Cryptococcus neoformans is characterized by its ability to induce a distinct polysaccharide capsule in response to a number of host-specific environmental stimuli. The induction of capsule is a complex biological process encompassing regulation at multiple steps, including the biosynthesis, transport, and maintenance of the polysaccharide at the cell surface. By precisely regulating the composition of its cell surface and secreted polysaccharides, C. neoformans has developed intricate ways to establish chronic infection and dormancy in the human host. The plasticity of the capsule structure in response to various host conditions also underscores the complex relationship between host and parasite. Much of this precise regulation of capsule is achieved through the transcriptional responses of multiple conserved signaling pathways that have been coopted to regulate this C. neoformans-specific virulence-associated phenotype. This review focuses on specific host stimuli that trigger the activation of the signal transduction cascades and on the downstream transcriptional responses that are required for robust encapsulation around the cell. PMID:22763631
D 2 and DT Liquid-Layer Target Shots on NIF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas
Experiments at the National Ignition Facility (NIF) using targets containing a Deuterium-Tritium (DT) fuel layer have, until recently, required that a high-quality layer of solid deuterium-tritium (herein referred to as an "ice-layer") be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of icelayers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam lined capsule, but also changes to the capsule filling process andmore » the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. These changes, and the target's performance during four target shots on NIF will be discussed.« less
D 2 and D-T Liquid-Layer Target Shots at the National Ignition Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas
Experiments at the National Ignition Facility (NIF) using targets containing a deuterium-tritium (D-T) fuel layer have, until recently, required that a high-quality layer of solid D-T (herein referred to as an ice layer) be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of ice layers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam-lined capsule but also changes to the capsule filling processmore » and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. Finally, these changes and the target’s performance during four target shots on NIF are discussed.« less
Airborne Observation of the Hayabusa Sample Return Capsule Re-Entry
NASA Technical Reports Server (NTRS)
Grinstead, Jay H.; Jenniskens, Peter; Cassell, Alan M.; Albers, James; Winter, Michael W.
2011-01-01
NASA Ames Research Center and the SETI Institute collaborated on an effort to observe the Earth re-entry of the Japan Aerospace Exploration Agency's Hayabusa sample return capsule. Hayabusa was an asteroid exploration mission that retrieved a sample from the near-Earth asteroid Itokawa. Its sample return capsule re-entered over the Woomera Prohibited Area in southern Australia on June 13, 2010. Being only the third sample return mission following NASA's Genesis and Stardust missions, Hayabusa's return was a rare opportunity to collect aerothermal data from an atmospheric entry capsule returning at superorbital speeds. NASA deployed its DC-8 airborne laboratory and a team of international researchers to Australia for the re-entry. For approximately 70 seconds, spectroscopic and radiometric imaging instruments acquired images and spectra of the capsule, its wake, and destructive re-entry of the spacecraft bus. Once calibrated, spectra of the capsule will be interpreted to yield data for comparison with and validation of high fidelity and engineering simulation tools used for design and development of future atmospheric entry system technologies. A brief summary of the Hayabusa mission, the preflight preparations and observation mission planning, mission execution, and preliminary spectral data are documented.
Implantable telemetry capsule for monitoring arterial oxygen saturation and heartbeat.
Kuwana, K; Dohi, T; Hashimoto, Y; Matsumoto, K; Shimoyama, I
2008-01-01
In this study, we have developed an implantable telemetry capsule for monitoring heartbeat. The capsule has three main functions, monitoring vital signs, transmitting the vital signs, and receiving energy for driving the capsule without wires. We used two wavelengths of LEDs and a photodiode sensitive to the two wavelengths for heartbeat sensor. The arterial oxygen saturation is calculated from the amplitude of the heartbeat signal. We fabricated an FM transmitter whose carrier frequency was 80 MHz. Though the GHz range frequency is generally used in transmission, the attenuation in the human body is large. The size of a common linear antenna is about a quarter of its operating wavelength. We employed a coil-based antenna which can reduce size below the quarter of the wavelength. We fabricated a miniaturized transmitter with the coil-based antenna at lower frequency. Our capsule was driven intermittently. We used a rechargeable battery. When the battery ran down, the battery was charged by wireless using the induced electromotive force. This means that the capsule is capable of monitoring vital signs over the long term. We measured the heartbeat from the middle finger of hand in a water tank as a model of a human body.
Synthetic quorum sensing in model microcapsule colonies
NASA Astrophysics Data System (ADS)
Shum, Henry; Balazs, Anna C.
2017-08-01
Biological quorum sensing refers to the ability of cells to gauge their population density and collectively initiate a new behavior once a critical density is reached. Designing synthetic materials systems that exhibit quorum sensing-like behavior could enable the fabrication of devices with both self-recognition and self-regulating functionality. Herein, we develop models for a colony of synthetic microcapsules that communicate by producing and releasing signaling molecules. Production of the chemicals is regulated by a biomimetic negative feedback loop, the “repressilator” network. Through theory and simulation, we show that the chemical behavior of such capsules is sensitive to both the density and number of capsules in the colony. For example, decreasing the spacing between a fixed number of capsules can trigger a transition in chemical activity from the steady, repressed state to large-amplitude oscillations in chemical production. Alternatively, for a fixed density, an increase in the number of capsules in the colony can also promote a transition into the oscillatory state. This configuration-dependent behavior of the capsule colony exemplifies quorum-sensing behavior. Using our theoretical model, we predict the transitions from the steady state to oscillatory behavior as a function of the colony size and capsule density.
Enthalpy generation from mixing in hohlraum-driven targets
NASA Astrophysics Data System (ADS)
Amendt, Peter; Milovich, Jose
2016-10-01
The increase in enthalpy from the physical mixing of two initially separated materials is analytically estimated and applied to ICF implosions and gas-filled hohlraums. Pressure and temperature gradients across a classical interface are shown to be the origin of enthalpy generation from mixing. The amount of enthalpy generation is estimated to be on the order of 100 Joules for a 10 micron-scale annular mixing layer between the solid deuterium-tritium fuel and the undoped high-density carbon ablator of a NIF-scale implosion. A potential resonance is found between the mixing layer thickness and gravitational (Cs2/ g) and temperature-gradient scale lengths, leading to elevated enthalpy generation. These results suggest that if mixing occurs in current capsule designs for the National Ignition Facility, the ignition margin may be appreciably eroded by the associated enthalpy of mixing. The degree of enthalpy generation from mixing of high- Z hohlraum wall material and low- Z gas fills is estimated to be on the order of 100 kJ or more for recent NIF-scale hohlraum experiments, which is consistent with the inferred missing energy based on observed delays in capsule implosion times. Work performed under the auspices of Lawrence Livermore National Security, LLC (LLNS) under Contract No. DE-AC52-07NA27344.
Mercury Capsule Model in the 1- by 1-Foot Supersonic Wind Tunnel
1959-10-21
National Aeronautics and Space Administration (NASA) researchers install a small-scale model of the capsule for Project Mercury in the 1- by 1-Foot Supersonic Wind Tunnel at the Lewis Research Center. NASA Lewis conducted a variety of tests for Project Mercury, including retrorocket calibration, escape tower engine performance, and separation of the capsule from simulated Atlas and Redstone boosters. The test of this capsule and escape tower model in the 1- by 1-foot tunnel were run in January and February 1960. The 1-by 1-Foot Supersonic Wind Tunnel had a 15-inch long test section, seen here, that was one foot wide and one foot high. The sides were made of glass to allow cameras to capture the supersonic air flow over the models. The tunnel could generate air flows from Mach 1.3 to 3.0. At the time, it was one of nine small supersonic wind tunnels at Lewis. These tunnels used the exhauster and compressor equipment of the larger facilities. The 1- by 1 tunnel, which began operating in the early 1950s, was built inside a test cell in the expansive Engine Research Building. During the 1950s the 1- by 1 was used to study a variety of inlets, nozzles, and cones for missiles and scramjets. The Mercury capsule tests were among the last at the facility for many years. The tunnel was mothballed in 1960. The 1- by 1 was briefly restored in 1972, then brought back online for good in 1979. The facility has maintained a brisk operating schedule ever since.
Mueller, Casey A; Joss, Jean M P; Seymour, Roger S
2011-10-01
The effects of oxygen partial pressure ([Formula: see text]) on development and respiration were investigated in the eggs of the Australian lungfish, Neoceratodus forsteri. At 20°C, embryonic survival and development was optimal at 15 and 20.9 kPa. Development was slowed at 5 and 10 kPa and embryos did not survive 2 kPa. At lower [Formula: see text], the rate of oxygen consumption also decreased. Embryos responded to hypoxia by hatching at an earlier age and stage of development, and hatching wet and dry gut-free masses were reduced. The role of oxygen conductance ([Formula: see text]) in gas exchange was also examined under selected environmental [Formula: see text] and temperatures. The breakdown of the vitelline membrane changed capsule geometry, allowed water to be absorbed into the perivitelline space and increased capsule [Formula: see text]. This occurred at embryonic stage 32 under all treatments and was largely independent of both [Formula: see text] and temperature (15, 20 and 25°C), demonstrating that capsule [Formula: see text] cannot adaptively respond to altered environmental conditions. The membrane breakdown increased capsule diffusive [Formula: see text] and stabilised perivitelline [Formula: see text], but reduced the convective [Formula: see text] of the perivitelline fluid, as the large perivitelline volume and inadequate convective current resulted in a [Formula: see text] gradient within the egg prior to hatch.
Magnetically guided capsule endoscopy.
Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M
2017-08-01
Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.
Catheterless Long-Term Ambulatory Urodynamic Measurement Using a Novel Three-Device System
Wille, Sebastian; Schumacher, Pauline; Paas, Jenny; Tenholte, Dirk; Eminaga, Okyaz; Müller, Ute; Muthen, Noemi; Mehner, Jan; Cornely, Oliver; Engelmann, Udo
2014-01-01
Aims Long-term urodynamics are required because bladder-emptying disorders are often not clearly revealed by conventional urodynamics. Patients with severe clinical overactive bladder symptoms, for instance, often show normal results. This may be due to the short evaluation time and psychological factors that complicate conventional urodynamics. This study aimed to develop an ambulatory three-component urodynamic measurement system that is easy to operate, registers urodynamic parameters for several days, and has no negative impact on the patient. Methods We developed an intravesical capsule combined with a hand-held device to register voiding desire and micturition, and an alarm pad device that detects urine loss. Recently, the intravesical capsule and its proven function were detailed in the literature. Here, we present detailed in vitro results using a female bladder model. The flexible capsule was C-shaped to minimize the risk of expulsion from the bladder during micturition. Results of biocompatibility evaluation of the intravesical capsule, which is called Wille Capsule (WiCa) are described. Results The WiCa with an oval nose and a maximum outer diameter of 5.5 mm was easily inserted through a 25-French cystoscope. Removing the WiCa by grasping the nose using the female model with bladder was easily conducted. Expulsion of the WiCa during voiding was avoided through a novel C-shaped device design. Based on in vitro cytotoxicity studies, the capsule is a promising and safe device. Conclusion Our novel system is an innovative minimally-invasive tool for accurate long-term urodynamic measurement, and does not require inserting a transurethral catheter. PMID:24840482
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Reaves, Mercedes C.
2008-01-01
As NASA moves towards developing technologies needed to implement its new Exploration program, studies conducted for Apollo in the 1960's to understand the rollover stability of capsules landing are being revisited. Although rigid body kinematics analyses of the roll-over behavior of capsules on impact provided critical insight to the Apollo problem, extensive ground test programs were also used. For the new Orion spacecraft being developed to implement today's Exploration program, new air-bag designs have improved sufficiently for NASA to consider their use to mitigate landing loads to ensure crew safety and to enable re-usability of the capsule. Simple kinematics models provide only limited understanding of the behavior of these air bag systems, and more sophisticated tools must be used. In particular, NASA and its contractors are using the LS-Dyna nonlinear simulation code for impact response predictions of the full Orion vehicle with air bags by leveraging the extensive air bag prediction work previously done by the automotive industry. However, even in today's computational environment, these analyses are still high-dimensional, time consuming, and computationally intensive. To alleviate the computational burden, this paper presents an approach that uses deterministic sampling techniques and an adaptive response surface method to not only use existing LS-Dyna solutions but also to interpolate from LS-Dyna solutions to predict the stability boundaries for a capsule on airbags. Results for the stability boundary in terms of impact velocities, capsule attitude, impact plane orientation, and impact surface friction are discussed.
NASA Astrophysics Data System (ADS)
Gora, Michalina J.; Simmons, Leigh H.; Tiernan, Aubrey R.; Grant, Catriona N.; Soomro, Amna R.; Walker Corkery, Elizabeth S.; Rosenberg, Mireille; Metlay, Joshua P.; Tearney, Guillermo J.
2016-03-01
We have developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires microscopic images of the entire esophagus in unsedated subjects in a quick and comfortable procedure. To test its capabilities of TCE to become a population-based screening device, we conducted a clinical feasibility study in the primary care office. The swept-source OCT imaging system (1310nm central wavelength, 40kHz A-line rate, 10um axial resolution) together with the tethered capsule catheter (11x25mm capsule attached to a flexible tether) were transferred to the PCP office where unsedated patients scheduled for non-urgent PCP visits swallowed the capsule and microscopic OCT images of the entire esophagus were collected. After the whole length of the esophagus was imaged, the catheter was disinfected for reuse. Twenty subjects were enrolled in the study, including nine female and eleven male. All TCE procedures were performed by a nurse and lasted in average 5:42 ± 1:54 min. High-resolution images of the esophagus were obtained in all seventeen subjects that swallowed the capsule. Our clinical experience in this cohort, subject feedback, image quality, and technological adaptations for efficient utilization in this setting will be presented. The ease and simplicity of the procedure combined with high quality of the images demonstrate the potential for this technology to become a population-based screening device. Technology limitations and future development guided by findings from this initial experience will be discussed with the goal of effectively translating TCE to the outpatient primary care setting.
Kim, Sang Jun; Choi, Yu Seong
2015-01-01
Corticosteroid injection has a wide range of success in adhesive capsulitis but the reason for this has not yet been explained. We hypothesized that this difference might be due to the distribution of the corticosteroids injected into the joint cavity because particulate steroid deposits in the capsule and will not be moved over time by shoulder motion. The purpose of this study is to determine whether the therapeutic efficacy of particulate corticosteroid injection into the glenohumeral joint differs according to the dispersion pattern. Prospective evaluation. Outpatient clinics at a tertiary university hospital. Seventy-two patients diagnosed as having adhesive capsulitis received a corticosteroid injection at the glenohumeral joint. The posterior capsule and the subscapular bursa were selected as dispersion sites and the dispersion of contrast dye was expressed as a ratio (%). Two weeks and 3 months after the injection clinical improvement ("not improved," "slightly improved," "much improved"), numeric rating scale (NRS), and passive range of motions (PROM) were evaluated. The dispersion of the contrast dye was compared according to the clinical improvements by an analysis of variance test. Pearson correlation test was done to find the relationship between PROM and the dispersion and between change of NRS and the dispersion. The distribution in the subscapular area was 30.0% in the "much improved" group, 22.0% in the "slightly improved" group, and 37.1% in the "no improvement" group which was not significantly different (P = 0.179). Correlations between changes of NRS and the dye distribution were not statistically significant (P = 0.429 at 2 weeks and P = 0.629 at 3 months). The change of passive external rotation 3 months after the injection was significantly correlated with the dye distribution (P = 0.035). Because of diverse pathologic findings in adhesive capsulitis, further studies will be needed to address the effect of the dye distribution on the pain improvement according to pathologic findings revealed by magnetic resonance imaging (MRI). External rotation of the shoulder in adhesive capsulitis has greater improvement as the corticosteroid solutions injected into the glenohumeral joint are increasingly dispersed to the subscapularis area. However, this does not affect the pain improvement after the injection.
Correia, Clara R; Santos, Tírcia C; Pirraco, Rogério P; Cerqueira, Mariana T; Marques, Alexandra P; Reis, Rui L; Mano, João F
2017-04-15
Capsules coated with polyelectrolytes and co-encapsulating adipose stem (ASCs) and endothelial (ECs) cells with surface modified microparticles are developed. Microparticles and cells are freely dispersed in a liquified core, responsible to maximize the diffusion of essential molecules and allowing the geometrical freedom for the autonomous three-dimensional (3D) organization of cells. While the membrane wraps all the instructive cargo elements within a single structure, the microparticles provide a solid 3D substrate for the encapsulated cells. Our hypothesis is that inside this isolated biomimetic 3D environment, ECs would lead ASCs to differentiate into the osteogenic lineage to ultimately generate a mineralized tissue in vivo. For that, capsules encapsulating only ASCs (MONO capsules) or co-cultured with ECs (CO capsules) are subcutaneously implanted in nude mice up to 6weeks. Capsules implanted immediately after production or after 21days of in vitro osteogenic stimulation are tested. The most valuable outcome of the present study is the mineralized tissue in CO capsules without in vitro pre-differentiation, with similar levels compared to the pre-stimulated capsules in vitro. We believe that the proposed bioencapsulation strategy is a potent self-regulated system, which might find great applicability in bone tissue engineering. The diffusion efficiency of essential molecules for cell survival is a main issue in cell encapsulation. Former studies reported the superior biological outcome of encapsulated cells within liquified systems. However, most cells used in TE are anchorage-dependent, requiring a solid substrate to perform main cellular processes. We hypothesized that liquified capsules encapsulating microparticles are a promising attempt. Inspired by the multiphenotypic cellular environment of bone, we combine the concept of liquified capsules with co-cultures of stem and endothelial cells. After implantation, results show that co-cultured capsules without in vitro stimulation were able to form a mineralized tissue in vivo. We believe that the present ready-to-use TE strategy requiring minimum in vitro manipulation will find great applicability in bone tissue engineering. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
SITE TECHNOLOGY CAPSULE: TERRA-KLEEN SOLVENT EXTRACTION TECHNOLOGY
Remediation of PCBs in soils has been difficult to implement on a full-scale, cost-effective basis. The Terra-Kleen solvent extraction system has overcome many of the soil handling, contaminant removal, and regulatory restrictions that have made it difficult to implement a cost-e...
Management of the Cs/Sr Capsule Project at the Hanford Site. Technology Readiness Assessment Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The Federal Project Director (FPD) for the U.S. Department of Energy (DOE), Richland Operations Office (RL) Waste Management and D&D Division (WMD) requested a Technology Readiness Assessment (TRA) for the Management of the Cesium/Strontium Capsule Storage Project (MCSCP) at the Waste Encapsulation and Storage Facility (WESF) on the Hanford Site in Washington State. The MCSCP CD-1 TRA was performed by a team selected in collaboration between the Office of Environmental Management (EM) Chief Engineer (EM-3.3) and RL, WMD FPD. The TRA Team included subject matter and technical experts having experience in cask storage, process engineering, and system design who weremore » independent of the MCSCP, and the team was led by the Director of Operations and Processes from the EM Chief Engineer's Office (EM-3.32). Movement of the Cs/Sr capsules to dry storage, based on information from the conceptual design, involves (1) capsule packaging, (2) capsule transfer, and (3) capsule storage. The project has developed a conceptual process, described in 30059-R-02, "NAC Conceptual Design Report for the Management of the Cesium and Strontium Capsules Project", which identifies the five major activities in the process to complete the transfer from storage pool to pad-mounted cask storage. The process, shown schematically in Figure 1, is comprised of the following process steps: (1) loading capsules into the UCS; (2) UCS processing; (3) UCS insertion into the TSC Basket; (4) cask transport from WESF to CSA and (5) extended storage at the CSA.« less
NASA Astrophysics Data System (ADS)
Do, Dukho; Alali, Sanaz; Kang, DongKyun; Tabatabaie, Nima; Lu, Weina; Grant, Catriona N.; Soomro, Amna R.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.
2016-03-01
Eosinophilic Esophagitis (EoE) is caused by food allergies, and defined by histological presence of eosinophil cells in the esophagus. The current gold standard for EoE diagnosis is endoscopy with pinch biopsy to detect more than 15 eosinophils/ High power field (HPF). Biopsy examinations are expensive, time consuming and are difficult to tolerate for patients. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology capable of imaging individual eosinophils as highly scattering cells (diameter between 8 µm to 15 µm) in the epithelium. Our lab has developed a tethered SECM capsule that can be swallowed by unsedated patients. The capsule acquires large area confocal images, equivalent to more than 30,000 HPFs, as it traverses through the esophagus. In this paper, we present the outcome of a clinical study using the tethered SECM capsule for diagnosing EoE. To date, 32 subjects have been enrolled in this study. 88% of the subjects swallowed the capsules without difficulty and of those who swallowed the capsule, 95% preferred the tethered capsule imaging procedure to sedated endoscopic biopsy. Each imaging session took about 12 ± 2.4 minutes during which 8 images each spanning of 24 ± 5 cm2 of the esophagus were acquired. SECM images acquired from EoE patients showed abundant eosinophils as highly scattering cells in squamous epithelium. Results from this study suggest that the SECM capsule has the potential to become a less-invasive, cost-effective tool for diagnosing EoE and monitoring the response of this disease to therapy.
A NASA technician paints NASA's first Orion full-scale abort flight test crew module.
2008-03-31
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-04-01
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
Greenberg, BD; Gabriels, LA; Malone, DA; Rezai, AR; Friehs, GM; Okun, MS; Shapira, NA; Foote, KD; Cosyns, PR; Kubu, CS; Malloy, PF; Salloway, SP; Giftakis, JE; Rise, MT; Machado, AG; Baker, KB; Stypulkowski, PH; Goodman, WK; Rasmussen, SA; Nuttin, BJ
2013-01-01
Psychiatric neurosurgery teams in the United States and Europe have studied deep brain stimulation (DBS) of the ventral anterior limb of the internal capsule and adjacent ventral striatum (VC/VS) for severe and highly treatment-resistant obsessive-compulsive disorder. Four groups have collaborated most closely, in small-scale studies, over the past 8 years. First to begin was Leuven/Antwerp, followed by Butler Hospital/Brown Medical School, the Cleveland Clinic and most recently the University of Florida. These centers used comparable patient selection criteria and surgical targeting. Targeting, but not selection, evolved during this period. Here, we present combined long-term results of those studies, which reveal clinically significant symptom reductions and functional improvement in about two-thirds of patients. DBS was well tolerated overall and adverse effects were overwhelmingly transient. Results generally improved for patients implanted more recently, suggesting a ‘learning curve’ both within and across centers. This is well known from the development of DBS for movement disorders. The main factor accounting for these gains appears to be the refinement of the implantation site. Initially, an anterior–posterior location based on anterior capsulotomy lesions was used. In an attempt to improve results, more posterior sites were investigated resulting in the current target, at the junction of the anterior capsule, anterior commissure and posterior ventral striatum. Clinical results suggest that neural networks relevant to therapeutic improvement might be modulated more effectively at a more posterior target. Taken together, these data show that the procedure can be successfully implemented by dedicated interdisciplinary teams, and support its therapeutic promise. PMID:18490925
Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani
2015-01-01
The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.
Scaling up feasibility of the production of solid lipid nanoparticles (SLN).
Gohla, S H; Dingler, A
2001-01-01
Solid lipid nanoparticles (SLN/Lipopearls) are widely discussed as colloidal drug carrier system. In contrast to polymeric systems, such as polylactic copolyol capsules, these systems show up with a good biocompatibility, if applied parenterally. The solid lipid matrices can be comprised of fats or waxes and allow protection of incorporated active ingredients against chemical and physical degradation. The SLN can either be produced by "hot homogenisation" of melted lipids at elevated temperatures or a "cold homogenization" process. This paper deals with production technologies for SLN formulations, based on non-ethoxylated fat components for topical application and high pressure homogenization (APV Deutschland GmbH, D-Lübeck). Based on the chosen fat components, a novel and easy manufacturing and scaling up method was developed to maintain chemical and physical integrity of encapsulated active and carrier.
Henney, Herbert R; Fitzpatrick, Anthony; Stewart, Johnston; Runyan, Jacob D
2008-12-01
The alpha2-adrenergic agonist tizanidine has been reported to have a narrow therapeutic index. A multiparticulate capsule formulation of tizanidine has been developed in an attempt to improve patient tolerability. This study assessed bioequivalence between a single, intact, 6-mg capsule of tizanidine and the capsule contents sprinkled in applesauce in fasted healthy subjects. Healthy male and female subjects aged 18 to 45 years completed 2 treatment periods: one with a tizanidine 6-mg capsule administered intact and the other with capsule contents sprinkled in applesauce. The 2 treatment periods had a 6-day washout period between administrations. Plasma tizanidine concentrations were determined for blood samples collected over 24 hours after administration. All treatment-emergent adverse events were recorded and graded by intensity and relationship to the study drug (not, improbable, possible, probable, definite) by the attending physician based on his or her clinical impression. A total of 19 men and 9 women (mean age, 26 years) completed the trial. Geometric mean natural logarithm-transformed AUC values (AUC(0-infinity) [AUC to infinity] and AUC(0-t) [AUC to the last measurable time point]) and C(max) ratios were significantly (P
Simakov, A. N.; Wilson, D. C.; Yi, S. A.; ...
2017-05-10
When used with 1.06-mm beryllium (Be) capsules on the National Ignition Facility, gold hohlraums with the inner diameter of 5.75 mm and helium gas fill density of 1.6 mg/cm 3 exhibit significant drive degradation due to laser energy backscatter (of order 14%–17%) and “missing” X-ray drive energy (about 32% during the main pulse). Also, hard to simulate cross-beam energy transfer (CBET) must be used to control the implosion symmetry. Larger, 6.72-mm hohlraums with fill densities ≤0.6 mg/cm 3 generally offer improved drive efficiency, reduced hot-electron preheat, and better control of the implosion symmetry without CBET. Recently, we carried out anmore » exploratory campaign to evaluate performance of 1.06-mm Be capsules in such hohlraums and determine optimal hohlraum parameters. Specifically, we performed in this paper a hohlraum fill-density scan with a three-shock, 9.5-ns laser pulse and found that an appropriate axial laser repointing and azimuthal outer-quad splitting resulted in significantly improved hohlraum energetics at fill densities ≤0.3 mg/cm 3 (with backscattered and “missing” energies being of about 5% and 23% of the total laser energy, respectively). The capsule shape at stagnation was slightly oblate and improved with lowering the fill density. We also performed an implosion with a lower-picket, 12.6-ns pulse at the hohlraum fill density of 0.15 mg/cm 3 to observe comparable hohlraum energetics (about 3% of backscattered and 27% of “missing” energy) but an even more oblate implosion shape. Finally, achieving symmetric implosions of 1.06-mm Be capsules in low-fill, 6.72-mm gold hohlraums with reasonably low-adiabat pulses may not be feasible. However, symmetric implosions have recently been successfully demonstrated in such hohlraums with 0.8-mm Be capsules.« less
Supercooling Water in Cylindrical Capsules
NASA Astrophysics Data System (ADS)
Guzman, J. J. Milón; Braga, S. L.
2005-11-01
An experimental apparatus was developed to investigate the supercooling phenomenon of water inside cylindrical capsules used for a cold storage process. The coolant is a water-alcohol mixture controlled by a constant temperature bath (CTB). Temperatures varying with time are measured inside and outside the capsule. Cylinders with an internal diameter and thickness of 45 and 1.5 mm, respectively, were made from four different materials: acrylic, PVC, brass, and aluminum. The supercooling period of the water and the nucleation temperature were investigated for different coolant temperatures. The supercooling and nucleation probabilities are shown as a function of the coolant temperature for the four different materials.
Implemented a wireless communication system for VGA capsule endoscope.
Moon, Yeon-Kwan; Lee, Jyung Hyun; Park, Hee-Joon; Cho, Jin-Ho; Choi, Hyun-Chul
2014-01-01
Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.
Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope.
Gao, Mingyuan; Hu, Chengzhi; Chen, Zhenzhi; Zhang, Honghai; Liu, Sheng
2010-12-01
This paper investigates design, modeling, simulation, and control issues related to self-propelled endoscopic capsule navigated inside the human body through external magnetic fields. A novel magnetic propulsion system is proposed and fabricated, which has great potential of being used in the field of noninvasive gastrointestinal endoscopy. Magnetic-analysis model is established and finite-element simulations as well as orthogonal design are performed for obtaining optimized mechanical and control parameters for generating appropriate external magnetic field. Simulated intestinal tract experiments are conducted, demonstrating controllable movement of the capsule under the developed magnetic propulsion system.
SITE TECHNOLOGY CAPSULE: IN SITU STEAM ENHANCED RECOVERY PROCESS
The SERP technology is designed to treat soils contaminated with VOCs and SVOCs in situ. Steam injection and vacuum extraction are used to remove the organic compounds from the soil and concentrate them for disposal or recycling. A full-scale demonstration of SERP was conducted a...
Praveen, Mamidipudi R; Shah, Gauri D; Vasavada, Abhay R; Dave, Khyati H
2015-09-01
To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT (Alcon Laboratories, Fort Worth, Texas, USA), on the development of posterior capsule opacification (PCO) 5 years postoperatively. Prospective, observational, consecutive, case series. setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India. Three hundred and ninety eyes with uncomplicated age-related cataract were included. Patients with diabetes mellitus, glaucoma, high myopia, pseudoexfoliation, traumatic cataract, subluxated cataract, previous ocular surgeries, and allergy to dilating drops were excluded. intervention procedures: Digital retroillumination photographic documentation was performed and analyzed for PCO using Evaluation of Posterior Capsule Opacification software. The scores and areas were calculated. PCO development and the influence of the anterior capsule cover (total on and part on) on the IOL optic was studied within the capsulorrhexis margin and the central 3.0 mm optic area. There was a significant increase in PCO up to 3 years. No significant change in PCO was observed between 3 and 5 years within the capsulorrhexis margin and central 3.0 mm optic area. In the total on group, within the capsulorrhexis margin, significantly lower scores and areas were observed when compared with part-on scores and areas. The increase in PCO up to 3 years was significant. Stabilization in PCO was observed between 3 and 5 years with no difference at 5 years. There was a low incidence of PCO in eyes with total anterior capsule cover over the IOL optic. Copyright © 2015 Elsevier Inc. All rights reserved.
Ughi, Giovanni J.; Gora, Michalina J.; Swager, Anne-Fré; Soomro, Amna; Grant, Catriona; Tiernan, Aubrey; Rosenberg, Mireille; Sauk, Jenny S.; Nishioka, Norman S.; Tearney, Guillermo J.
2016-01-01
Optical coherence tomography (OCT) is an optical diagnostic modality that can acquire cross-sectional images of the microscopic structure of the esophagus, including Barrett’s esophagus (BE) and associated dysplasia. We developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires high-resolution images of entire gastrointestinal (GI) tract luminal organs. This device has a potential to become a screening method that identifies patients with an abnormal esophagus that should be further referred for upper endoscopy. Currently, the characterization of the OCT-TCE esophageal wall data set is performed manually, which is time-consuming and inefficient. Additionally, since the capsule optics optimally focus light approximately 500 µm outside the capsule wall and the best quality images are obtained when the tissue is in full contact with the capsule, it is crucial to provide feedback for the operator about tissue contact during the imaging procedure. In this study, we developed a fully automated algorithm for the segmentation of in vivo OCT-TCE data sets and characterization of the esophageal wall. The algorithm provides a two-dimensional representation of both the contact map from the data collected in human clinical studies as well as a tissue map depicting areas of BE with or without dysplasia. Results suggest that these techniques can potentially improve the current TCE data acquisition procedure and provide an efficient characterization of the diseased esophageal wall. PMID:26977350
Chabot, Donald J; Ribot, Wilson J; Joyce, Joseph; Cook, James; Hepler, Robert; Nahas, Debbie; Chua, Jennifer; Friedlander, Arthur M
2016-07-25
The efficacy of currently licensed anthrax vaccines is largely attributable to a single Bacillus anthracis immunogen, protective antigen. To broaden protection against possible strains resistant to protective antigen-based vaccines, we previously developed a vaccine in which the anthrax polyglutamic acid capsule was covalently conjugated to the outer membrane protein complex of Neisseria meningitidis serotype B and demonstrated that two doses of 2.5μg of this vaccine conferred partial protection of rhesus macaques against inhalational anthrax . Here, we demonstrate complete protection of rhesus macaques against inhalational anthrax with a higher 50μg dose of the same capsule conjugate vaccine. These results indicate that B. anthracis capsule is a highly effective vaccine component that should be considered for incorporation in future generation anthrax vaccines. Published by Elsevier Ltd.
Tusor, Nora; Wusthoff, Courtney; Smee, Natalie; Merchant, Nazakat; Arichi, Tomoki; Allsop, Joanna M; Cowan, Frances M; Azzopardi, Denis; Edwards, A David; Counsell, Serena J
2012-07-01
Objective biomarkers are needed to assess neuroprotective therapies after perinatal hypoxic-ischemic encephalopathy (HIE). We tested the hypothesis that, in infants who underwent therapeutic hypothermia after perinatal HIE, neurodevelopmental performance was predicted by fractional anisotropy (FA) values in the white matter (WM) on early diffusion tensor imaging (DTI) as assessed by means of tract-based spatial statistics (TBSS). We studied 43 term infants with HIE. Developmental assessments were carried out at a median (range) age of 24 (12-28) mo. As compared with infants with favorable outcomes, those with unfavorable outcomes had significantly lower FA values (P < 0.05) in the centrum semiovale, corpus callosum (CC), anterior and posterior limbs of the internal capsule, external capsules, fornix, cingulum, cerebral peduncles, optic radiations, and inferior longitudinal fasciculus. In a second analysis in 32 assessable infants, the Griffiths Mental Development Scales (Revised) (GMDS-R) showed a significant linear correlation (P < 0.05) between FA values and developmental quotient (DQ) and all its component subscale scores. DTI analyzed by TBSS provides a qualified biomarker that can be used to assess the efficacy of additional neuroprotective therapies after HIE.
NASA Technical Reports Server (NTRS)
Kirk, Lindsay C.; Lillard, Randolph P.; Olejniczak, Joseph; Tanno, Hideyuki
2015-01-01
Computational assessments were performed to size boundary layer trips for a scaled Apollo capsule model in the High Enthalpy Shock Tunnel (HIEST) facility at the JAXA Kakuda Space Center in Japan. For stagnation conditions between 2 MJ/kg and 20 MJ/kg and between 10 MPa and 60 MPa, the appropriate trips were determined to be between 0.2 mm and 1.3 mm high, which provided kappa/delta values on the heatshield from 0.15 to 2.25. The tripped configuration consisted of an insert with a series of diamond shaped trips along the heatshield downstream of the stagnation point. Surface heat flux measurements were obtained on a capsule with a 250 mm diameter, 6.4% scale model, and pressure measurements were taken at axial stations along the nozzle walls. At low enthalpy conditions, the computational predictions agree favorably to the test data along the heatshield centerline. However, agreement becomes less favorable as the enthalpy increases conditions. The measured surface heat flux on the heatshield from the HIEST facility was under-predicted by the computations in these cases. Both smooth and tripped configurations were tested for comparison, and a post-test computational analysis showed that kappa/delta values based on the as-measured stagnation conditions ranged between 0.5 and 1.2. Tripped configurations for both 0.6 mm and 0.8 mm trip heights were able to effectively trip the flow to fully turbulent for a range of freestream conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Core, Gregory Matthew
This report contains a summary of irradiation testing of Fuel Cycle Research and Development (FCRD) Accident Tolerant Fuels Series 1 (ATF 1) experiments performed at Idaho National Laboratory (INL) in FY 2016. ATF 1 irradiation testing work performed in FY 2016 included design, analysis, and fabrication of ATF-1B drop in capsule ATF 1 series experiments and irradiation testing of ATF-1 capsules in the ATR.
Development of a novel tablet-in-capsule formulation of mesalamine for inflammatory bowel disease.
Patel, Mayur M; Amin, Avani F
2013-01-01
The objective of the present work was to develop a tablet-in-capsule type of multiunit system, which releases the drug in a controlled manner at pre-programmed time intervals. The system consists of an enteric-coated hydroxypropyl methylcellulose capsule filled with four units of mesalamine minitablets, each of which was further coated with different ratios of Eudragit(®) E100 and Eudragit(®) RS100. In vitro evaluation of tablets coated with Eudragit(®) E100 and Eudragit(®) RS100 at different pH conditions revealed that at lower pH levels (2.0, 3.6 and 5.5 pH), the drug release is mainly governed by the dissolution of Eudragit(®) E100 from the Eudragit(®) E100 and Eudragit(®) RS100 coat. In vitro evaluation of capsules enteric coated with Eudragit(®) L100 and Eudragit(®) S100 revealed that a maximum lag time of 3 h and 4 h was obtained, respectively. In vivo roentgenographic evaluation in rabbits revealed that the developed system remained intact until it reaches the targeted region of the gastrointestinal tract, i.e. ileum and colon, where the tablets were released after the dissolution of the enteric coat Eudragit(®) L100 and Eudragit(®) S100, respectively. The developed system exhibited a promising targeting behavior and hence may be used for the treatment of inflammatory bowel disease.
The microstructure of capsule containing self-healing materials: A micro-computed tomography study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Stappen, Jeroen, E-mail: Jeroen.Vanstappen@uge
Autonomic self-healing materials are materials with built-in (micro-) capsules or vessels, which upon fracturing release healing agents in order to recover the material's physical and mechanical properties. In order to better understand and engineer these materials, a thorough characterization of the material's microstructural behavior is essential and often overlooked. In this context, micro-computed tomography (μCT) can be used to investigate the three dimensional distribution and (de)bonding of (micro-) capsules in their native state in a polymer system with self-healing properties. Furthermore, in-situ μCT experiments in a self-healing polymer and a self-healing concrete system can elucidate the breakage and leakage behaviormore » of (micro-) capsules at the micrometer scale. While challenges related to image resolution and contrast complicate the characterization in specific cases, non-destructive 3D imaging with μCT is shown to contribute to the understanding of the link between the microstructure and the self-healing behavior of these complex materials. - Highlights: • μCT imaging allows for the analysis of microcapsule distribution patterns in self-healing materials. • μCT allows for qualitative and quantitative measurements of healing agent release from carriers in self-healing materials. • Experimental set-ups can be optimized by changing chemical compounds in the system to ensure maximum quality imaging.« less
Taavoni, Simin; Haghani, Hamid
2017-01-01
Menopausal symptoms experienced by women vary widely, and while many women transition through menopause with manageable symptoms, others experience severe symptoms, which may impair their quality of life. The purpose of this study was to determine the effect of Tribulus terrestris, ginger, saffron, and Cinnamomum on menopausal symptoms. A randomised, triple-blind, controlled trial design was used for this study. The participants were 80 postmenopausal women aged 50–60 years. A demographic data form and the Menopause Rating Scale were used to collect data. The women were randomly divided into two groups, each of which received either an Aphrodit capsule or a placebo twice a day for four weeks. The two bottles looked exactly the same, so that the investigator and the participants were not aware of the contents of the bottles. Each Aphrodit capsule contained 40 mg of Tribulus terrestris, 12.27 mg of Zingiber officinale, 3 mg of Crocus sativus extract, and 11 mg of Cinnamomum zeylanicum, while the placebo capsules contained 50 mg of starch. Descriptive and inferential statistics were used to analyse the data. A statistically significant change was reported in the menopausal symptoms of the intervention group compared with the placebo group. The results of the study demonstrate that the Aphrodit capsule was effective in reducing menopausal symptoms. PMID:28546803
Crack Extension and Possibility of Debonding in Encapsulation-Based Self-Healing Materials.
Li, Wenting; Jiang, Zhengwu; Yang, Zhenghong
2017-05-27
The breakage of capsules upon crack propagation is crucial for achieving crack healing in encapsulation-based self-healing materials. A mesomechanical model was developed in this study to simulate the process of crack propagation in a matrix and the potential of debonding. The model used the extended finite element method (XFEM) combined with a cohesive zone model (CZM) in a two-dimensional (2D) configuration. The configuration consisted of an infinite matrix with an embedded crack and a capsule nearby, all subjected to a uniaxial remote tensile load. A parametric study was performed to investigate the effect of geometry, elastic parameters and fracture properties on the fracture response of the system. The results indicated that the effect of the capsule wall on the fracture behavior of the matrix is insignificant for t c / R c ≤ 0.05. The matrix strength influenced the ultimate crack length, while the Young's modulus ratio E c / E m only affected the rate of crack propagation. The potential for capsule breakage or debonding was dependent on the comparative strength between capsule and interface (S c /S int ), provided the crack could reach the capsule. The critical value of S c ,cr /S int,cr was obtained using this model for materials design.
Steiner, Jessica Kathryne; Tasaki, Junichi; Rouhana, Labib
2016-01-01
Few animals are known to lay eggs in the absence of ovulation or copulation, as it is presumably energetically wasteful and subjected to negative selection. Characterization of Smed-boule, a member of the DAZ family of germline RNA-binding proteins, revealed that egg capsule (or capsule) production and deposition occurs independently of the presence of gametes in the planarian flatworm Schmidtea mediterranea. Reduction of Smed-boule expression by RNA-interference (RNAi) causes ablation of spermatogonial stem cells and the inability of ovarian germline stem cells to undergo oogenesis. Although animals subjected to Smed-boule RNAi lose their gametes and become sterile, they continue to lay egg capsules. Production of sterile capsules is even observed in virgin Smed-boule(RNAi) and control planarians maintained in complete isolation, demonstrating that egg production in S. mediterranea occurs independently of ovulation, fertilization, or mating. Evidence suggests that this is a conserved feature amongst Platyhelminthes, and therefore relevant to the pathology and dissemination of parasitic flatworms. These findings demonstrate that Smed-boule functions at different stages during male and female germline stem cell development, and also demonstrate that egg capsule production by planarian flatworms occurs independently of signals produced by mating or ova. PMID:27149082
Steiner, Jessica Kathryne; Tasaki, Junichi; Rouhana, Labib
2016-05-01
Few animals are known to lay eggs in the absence of ovulation or copulation, as it is presumably energetically wasteful and subjected to negative selection. Characterization of Smed-boule, a member of the DAZ family of germline RNA-binding proteins, revealed that egg capsule (or capsule) production and deposition occurs independently of the presence of gametes in the planarian flatworm Schmidtea mediterranea. Reduction of Smed-boule expression by RNA-interference (RNAi) causes ablation of spermatogonial stem cells and the inability of ovarian germline stem cells to undergo oogenesis. Although animals subjected to Smed-boule RNAi lose their gametes and become sterile, they continue to lay egg capsules. Production of sterile capsules is even observed in virgin Smed-boule(RNAi) and control planarians maintained in complete isolation, demonstrating that egg production in S. mediterranea occurs independently of ovulation, fertilization, or mating. Evidence suggests that this is a conserved feature amongst Platyhelminthes, and therefore relevant to the pathology and dissemination of parasitic flatworms. These findings demonstrate that Smed-boule functions at different stages during male and female germline stem cell development, and also demonstrate that egg capsule production by planarian flatworms occurs independently of signals produced by mating or ova.
Huyghebaert, Nathalie; Vermeire, An; Remon, Jean Paul
2004-04-01
The aim of this study was to develop an alternative method for enteric coating of HPMC capsules that avoids the sealing step before coating, resulting in ready-to-use enteric-coated capsules for the use in retail or hospital pharmacy or R&D sections of pharmaceutical industry and for the production of enteric-coated heat and moisture sensitive biomaterials. HPMC caps and bodies 00 (Vcaps, Capsugel) were coated separately in a fluid bed apparatus prior to filling (GPCG-1, Glatt) with Eudragit L30D-55 or Eudragit FS 30 D (Röhm), Aqoat AS-HF (Shin-Etsu) and Sureteric (Colorcon), using an optimised coating process. The coated bodies were filled and closed with the coated caps without encountering problems of coating damage. The release in 0.1N HCl after 2h from capsules coated with Eudragit L30D-55, Eudragit FS 30 D, Aqoat AS-HF and Sureteric was 0.6+/-.03, 0.6+/-0.3, 1.2+/-0.2 and 7.3+/-1.9%, respectively. The alternative method was reproducible and offered a way to overcome the time-consuming and expensive sealing step required using the conventional coating procedure. The obtained enteric-coated HPMC capsules can be stored (un)-filled for at least 6 months without loosing enteric properties.
Control and monitoring of oxygen fugacity in piston cylinder experiments
NASA Astrophysics Data System (ADS)
Matjuschkin, Vladimir; Brooker, Richard A.; Tattitch, Brian; Blundy, Jon D.; Stamper, Charlotte C.
2015-01-01
We present a newly developed capsule design that resolves some common problems associated with the monitoring and control of oxygen fugacity ( fO2) in high-pressure piston cylinder experiments. The new fO2 control assembly consists of an AuPd outer capsule enclosing two inner capsules: one of AuPd capsule containing the experimental charge (including some water), and the other of Pt containing a solid oxygen buffer plus water. The inner capsules are separated by crushable alumina. The outer capsule is surrounded by a Pyrex sleeve to simultaneously minimise hydrogen loss from the cell and carbon infiltration from the graphite furnace. Controlled fO2 experiments using this cell design were carried out at 1.0 GPa and 1,000 °C. We used NiPd, CoPd and (Ni, Mg)O fO2 sensors, whose pressure sensitivity is well calibrated, to monitor the redox states achieved in experiments buffered by Re-ReO2, Ni-NiO and Co-CoO, respectively. Results for the fO2 sensors are in good agreement with the intended fO2 established by the buffer, demonstrating excellent control for durations of 24-48 h, with uncertainties less than ± 0.3 log bar units of fO2.
Polypeptide multilayer film co-delivers oppositely-charged drug molecules in sustained manners.
Jiang, Bingbing; Defusco, Elizabeth; Li, Bingyun
2010-12-13
The current state-of-the-art for drug-carrying biomedical devices is mostly limited to those that release a single drug. Yet there are many situations in which more than one therapeutic agent is needed. Also, most polyelectrolyte multilayer films intended for drug delivery are loaded with active molecules only during multilayer film preparation. In this paper, we present the integration of capsules as vehicles within polypeptide multilayer films for sustained release of multiple oppositely charged drug molecules using layer-by-layer nanoassembly technology. Calcium carbonate (CaCO(3)) particles were impregnated with polyelectrolytes, shelled with polyelectrolyte multilayers, and then assembled onto polypeptide multilayer films using glutaraldehyde. Capsule-integrated polypeptide multilayer films were obtained after decomposition of CaCO(3) templates. Two oppositely charged drugs were loaded into capsules within polypeptide multilayer films postpreparation based on electrostatic interactions between the drugs and the polyelectrolytes impregnated within capsules. We determined that the developed innovative capsule-integrated polypeptide multilayer films could be used to load multiple drugs of very different properties (e.g., opposite charges) any time postpreparation (e.g., minutes before surgical implantation inside an operating room), and such capsule-integrated films allowed simultaneous delivery of two oppositely charged drug molecules and a sustained (up to two weeks or longer) and sequential release was achieved.
Polypeptide Multilayer Film Co-Delivers Oppositely-Charged Drug Molecules in Sustained Manners
Jiang, Bingbing; DeFusco, Elizabeth; Li, Bingyun
2010-01-01
The current state-of-the-art for drug-carrying biomedical devices is mostly limited to those that release a single drug. Yet there are many situations in which more than one therapeutic agent is needed. Also, most polyelectrolyte multilayer films intending for drug delivery are loaded with active molecules only during multilayer film preparation. In this paper, we present the integration of capsules as vehicles within polypeptide multilayer films for sustained release of multiple oppositely-charged drug molecules using layer-by-layer nanoassembly technology. Calcium carbonate (CaCO3) particles were impregnated with polyelectrolytes, shelled with polyelectrolyte multilayers, and then assembled onto polypeptide multilayer films using glutaraldehyde. Capsule-integrated polypeptide multilayer films were obtained after decomposition of CaCO3 templates. Two oppositely-charged drugs were loaded into capsules within polypeptide multilayer films post-preparation based on electrostatic interactions between the drugs and the polyelectrolytes impregnated within capsules. We determined that the developed innovative capsule-integrated polypeptide multilayer films could be used to load multiple drugs of very different properties (e.g. opposite charges) any time post-preparation (e.g. minutes before surgical implantation inside an operating room), and such capsule-integrated films allowed simultaneous delivery of two oppositely-charged drug molecules and a sustained (up to two weeks or longer) and sequential release was achieved. PMID:21058719
Silva, Eduardo Nascimento; Ribas-Filho, Jurandir Marcondes; Czeczko, Nicolau Gregori; Pachnicki, Jan Pawel Andrade; Netto, Mário Rodrigues Montemor; Lipinski, Leandro Cavalcante; Noronha, Lucia de; Colman, Joelmir; Zeni, João Otavio; Carvalho, Caroline Aragão de
2016-12-01
To assess the capsules formed by silicone implants coated with polyurethane foam and with a textured surface. Sixty-four Wistar albinus rats were divided into two groups of 32 each using polyurethane foam and textured surface. The capsules around the implants were analyzed for 30, 50, 70 and 90 days. Were analyzed the following parameters: foreign body reaction, granulation tissue, presence of myofibroblasts, neoangiogenesis, presence of synovial metaplasia, capsular thickness, total area and collagen percentage of type I and III, in capsules formed around silicone implants in both groups. The foreign body reaction was only present in the four polyurethane subgroups. The formation of granulation tissue and the presence of myofibroblasts were higher in the four polyurethane subgroups. Regarding to neoangiogenesis and synovial metaplasia, there was no statistical difference between the groups. Polyurethane group presented (all subgroups) a greater capsule thickness, a smaller total area and collagen percentage of type I and a higher percentage area of type III, with statistical difference. The use of polyurethane-coated implants should be stimulated by the long-term results in a more stable capsule and a lower incidence of capsular contracture, despite developing a more intense and delayed inflammatory reaction in relation to implants with textured surface.
SIMULTANEOUS PRODUCTION OF TWO CAPSULAR POLYSACCHARIDES BY PNEUMOCOCCUS
Austrian, Robert; Bernheimer, Harriet P.; Smith, Evelyn E. B.; Mills, George T.
1959-01-01
Study of the capsular genome of pneumococcus has shown that it controls a multiplicity of biochemical reactions essential to the synthesis of capsular polysaccharide. Mutation affecting any one of several biochemical reactions concerned with capsular synthesis may result in loss of capsulation without alteration of other biochemical functions similarly concerned. Mutations affecting the synthesis of uronic acids are an important cause of loss of capsulation and of virulence by strains of pneumococcus Type I and Type III. The capsular genome appears to have a specific location in the total genome of the cell, this locus being occupied by the capsular genome of whatever capsular type is expressed by the cell. Transformation of capsulated or of non-capsulated pneumococci to heterologous capsular type results probably from a genetic exchange followed by the development of a new biosynthetic pathway in the transformed cell. The new capsular genome is transferred to the transformed cell as a single particle of DNA. Binary capsulation results from the simultaneous presence within the pneumococcal cell of two capsular genomes, one mutated, the other normal. Interaction between the biochemical pathways controlled by the two capsular genomes leads to augmentation of the phenotypic expression of the product controlled by one and to partial suppression of the product determined by the other. Knowledge of the biochemical basis of binary capsulation can be used to indicate the presence of uronic acid in the capsular polysaccharide of a pneurnococcal type the composition of the capsule of which is unknown. PMID:13795197
Villa, Chiara; Manzoli, Vita; Abreu, Maria M.; Verheyen, Connor A.; Seskin, Michael; Najjar, Mejdi; Molano, R. Damaris; Torrente, Yvan; Ricordi, Camillo; Tomei, Alice A.
2017-01-01
Background Understanding the effects of capsule composition and transplantation site on graft outcomes of encapsulated islets will aid in the development of more effective strategies for islet transplantation without immunosuppression. Methods Here, we evaluated the effects of transplanting alginate (ALG)-based microcapsules (Micro) in the confined and well-vascularized epididymal fat pad (EFP) site, a model of the human omentum, as opposed to free-floating in the intraperitoneal cavity (IP) in mice. We also examined the effects of reinforcing ALG with polyethylene glycol (PEG). To allow transplantation in the EFP site, we minimized capsule size to 500 ± 17 μm. Unlike ALG, PEG resists osmotic stress, hence we generated hybrid microcapsules by mixing PEG and ALG (MicroMix) or by coating ALG capsules with a 15 ± 2 μm PEG layer (Double). Results We found improved engraftment of fully allogeneic BALB/c islets in Micro capsules transplanted in the EFP (median reversal time [MRT], 1 day) versus the IP site (MRT, 5 days; P < 0.01) in diabetic C57BL/6 mice and of Micro encapsulated (MRT, 8 days) versus naked (MRT, 36 days; P < 0.01) baboon islets transplanted in the EFP site. Although in vitro viability and functionality of islets within MicroMix and Double capsules were comparable to Micro, addition of PEG to ALG in MicroMix capsules improved engraftment of allogeneic islets in the IP site, but resulted deleterious in the EFP site, probably due to lower biocompatibility. Conclusions Our results suggest that capsule composition and transplant site affect graft outcomes through their effects on nutrient availability, capsule stability, and biocompatibility. PMID:27525644
Capsule endoscopy in the diagnosis of Crohn's disease.
Niv, Yaron
2013-01-01
Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.
Pan, Lin; Belloni, Paula; Ding, Han Ting; Wang, Jianshuang; Rubino, Christopher M; Putnam, Wendy S
2017-09-01
Pirfenidone film-coated tablets were developed to offer an alternative to the marketed capsule formulation. This study assessed the bioequivalence of the tablet and capsule formulations under fed and fasted states. A Phase I, open-label, randomized, four-treatment-period, four-sequence, crossover pharmacokinetics study (NCT02525484) was conducted. Each subject received an 801-mg single dose of pirfenidone as three 267-mg capsules or one 801-mg tablet under fasted and fed conditions. Pirfenidone plasma C max , AUC 0-t and AUC 0-∞ were used to assess bioequivalence. Forty-four subjects were randomized to treatment. The 801-mg tablet in the fasted state met bioequivalence criteria [90% confidence intervals (CI) 80.00-125.00%] for the GLSM ratios of natural log-transformed C max , AUC 0-t and AUC 0-∞ . Under fed conditions, the 801-mg tablet met the bioequivalence criteria for AUC 0-t and AUC 0-∞ , but slightly exceeded the bioequivalence criteria for the C max (90% CI of 108.26-125.60%). The tablet C max was approximately 17% higher than that of the capsules. In the fed state, the tablet C max , and both AUC 0-t and AUC 0-∞ were reduced by 39% and 17%, respectively, relative to the fasted state. The tablet and capsules had acceptable tolerability profiles. The pirfenidone 801-mg tablet met bioequivalence criteria when compared with three 267-mg capsules in the fasted state. The tablet C max was slightly higher relative to capsules in the fed state, but this is not expected to have a clinically meaningful impact on the benefit-risk profile of pirfenidone. This work was supported by F. Hoffmann-La Roche Ltd.
SECM half-inch tethered endoscopic capsule (HITEC) for esophageal imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kang, DongKyun; Kim, Minkyu; Carruth, Robert W.; Lu, Weina; Wu, Tao; Alali, Sanaz; Do, Dukho; Soomro, Amna R.; Grant, Catriona N.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.
2016-03-01
Spectrally encoded confocal microscopy (SECM) is a high-speed confocal endomicroscopy technology that can image extremely large regions of human tissue at cellular resolution within a short imaging time. Previously, we have developed a 7-mm-diameter SECM endoscopic capsule and successfully demonstrated imaging of human esophagus in vivo. Even though we were able to successfully capture images with the previous capsule, it suffered from two limitations: (1) the capsule had a small diameter, which provided a limited contact between SECM capsule and esophagus; and (2) speckle noise in SECM images made it challenging to appreciate cellular features. In this paper, we present a new SECM capsule, termed SECM half-inch tethered endoscopic capsule (HITEC), which addresses the two aforementioned technical challenges. With the SECM HITEC, a dual-clad fiber was used to reduce the speckle noise. Miniature GRIN optics was used to increase the NA of the fiber from 0.09 to 0.25, which made it possible to build a SECM capsule with large diameter (12.7 mm) while maintaining a short rigid length (22 mm). A water-immersion objective lens was custom designed and manufactured to provide high NA of 0.7. We have manufactured the SECM HITEC catheter and tested its optical and mechanical performance. Lateral and axial resolution was measured as 1.2 µm and 13 µm, respectively. We have imaged swine esophageal tissues ex vivo, and SECM images clearly visualized cell nuclei. Non-uniform rotational distortion (NURD) was small, less than 5%. Preliminary results suggest that SECM HITEC provides sufficient optical and mechanical performance for tissue imaging. In a future clinical study, we will test the feasibility of utilizing SECM HITEC for improved cellular imaging human of the human esophagus in vivo.
Gettman, Matthew T; Swain, Paul
2009-05-01
Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.
Capsule endoscopy: Current practice and future directions
Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E
2014-01-01
Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712
Mylonaki, M; Fritscher-Ravens, A; Swain, P
2003-01-01
Background: The development of wireless capsule endoscopy allows painless imaging of the small intestine. Its clinical use is not yet defined. The aim of this study was to compare the clinical efficacy and technical performance of capsule endoscopy and push enteroscopy in a series of 50 patients with colonoscopy and gastroscopy negative gastrointestinal bleeding. Methods: A wireless capsule endoscope was used containing a CMOS colour video imager, transmitter, and batteries. Approximately 50 000 transmitted images are received by eight abdominal aerials and stored on a portable solid state recorder, which is carried on a belt. Push enteroscopy was performed using a 240 cm Olympus video enteroscope. Results: Studies in 14 healthy volunteers gave information on normal anatomical appearances and preparation. In 50 patients with gastrointestinal bleeding and negative colonoscopy and gastroscopy, push enteroscopy was compared with capsule endoscopy. A bleeding source was discovered in the small intestine in 34 of 50 patients (68%). These included angiodysplasia (16), focal fresh bleeding (eight), apthous ulceration suggestive of Crohn’s disease (three), tumour (two), Meckel’s diverticulum (two), ileal ulcer (one), jejunitis (one), and ulcer due to intussusception (one). One additional intestinal diagnosis was made by enteroscopy. The yield of push enteroscopy in evaluating obscure bleeding was 32% (16/50). The capsule identified significantly more small intestinal bleeding sources than push enteroscopy (p<0.05). Patients preferred capsule endoscopy to push enteroscopy (p<0.001). Conclusions: In this study capsule endoscopy was superior to push enteroscopy in the diagnosis of recurrent bleeding in patients who had a negative gastroscopy and colonoscopy. It was safe and well tolerated. PMID:12865269
Current and Future Perspectives on Alginate Encapsulated Pancreatic Islet.
Strand, Berit L; Coron, Abba E; Skjak-Braek, Gudmund
2017-04-01
Transplantation of pancreatic islets in immune protective capsules holds the promise as a functional cure for type 1 diabetes, also about 40 years after the first proof of principal study. The concept is simple in using semipermeable capsules that allow the ingress of oxygen and nutrients, but limit the access of the immune system. Encapsulated human islets have been evaluated in four small clinical trials where the procedure has been evaluated as safe, but lacking long-term efficacy. Host reactions toward the biomaterials used in the capsules may be one parameter limiting the long-term function of the graft in humans. The present article briefly discusses important capsule properties such as stability, permeability and biocompatibility, as well as possible strategies to overcome current challenges. Also, recent progress in capsule development as well as the production of insulin-producing cells from human stem cells that gives promising perspectives for the transplantation of encapsulated insulin-producing tissue is briefly discussed. Stem Cells Translational Medicine 2017;6:1053-1058. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.
Khan, S. F.; MacLaren, S. A.; Salmonson, J. D.; ...
2016-04-27
Here, we introduce a new quasi 1-D implosion experimental platform at the National Ignition Facility designed to validate physics models as well as to study various Inertial Confinement Fusion aspects such as implosion symmetry, convergence, hydrodynamic instabilities, and shock timing. The platform has been developed to maintain shell sphericity throughout the compression phase and produce a round hot core at stagnation. This platform utilizes a 2-shock 1 MJ pulse with 340 TW peak power in a near-vacuum AuHohlraum and a CH ablator capsule uniformly doped with 1% Si. We also performed several inflight radiography, symmetry capsule, and shock timing experimentsmore » in order to tune the symmetry of the capsule to near round throughout several epochs of the implosion. Finally, adjusting the relative powers of the inner and outer cones of beams has allowed us to control the drive at the poles and equator of the capsule, thus providing the mechanism to achieve a spherical capsule convergence. Details and results of the tuning experiments are described.« less
Ultrasound capsule endoscopy: sounding out the future
Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P.; Desmulliez, Marc P. Y.; Steele, Robert J. C.; Näthke, Inke; Cochran, Sandy
2017-01-01
Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently. PMID:28567381
Zhang, Hongyang; Li, Yahui; Mi, Jianing; Zhang, Min; Wang, Yuerong; Jiang, Zhihong; Hu, Ping
2017-10-24
The fermentation products of Cordyceps sinensis ( C. sinensis ) mycelia are sustainable substitutes for natural C. sinensis . However, the volatile compositions of the commercial products are still unclear. In this paper, we have developed a simultaneous distillation-extraction (SDE) and gas chromatography-mass spectrometry (GC-MS) method for the profiling of volatile components in five fermentation products. A total of 64, 39, 56, 52, and 44 components were identified in the essential oils of Jinshuibao capsule (JSBC), Bailing capsule (BLC), Zhiling capsule (ZLC), Ningxinbao capsule (NXBC), and Xinganbao capsule (XGBC), respectively. 5,6-Dihydro-6-pentyl-2H-pyran-2-one (massoia lactone) was first discovered as the dominant component in JSBC volatiles. Fatty acids including palmitic acid (C16:0) and linoleic acid (C18:2) were also found to be major volatile compositions of the fermentation products. The multivariate partial least squares-discriminant analysis (PLS-DA) showed a clear discrimination among the different commercial products as well as the counterfeits. This study may provide further chemical evidences for the quality evaluation of the fermentation products of C. sinensis mycelia.
Properties of the spindle-to-cusp transition in extensional capsule dynamics
NASA Astrophysics Data System (ADS)
Dodson, W. R., III; Dimitrakopoulos, P.
2014-05-01
Our earlier letter (Dodson W. R. III and Dimitrakopoulos P., Phys. Rev. Lett., 101 (2008) 208102) revealed that a (strain-hardening) Skalak capsule in a planar extensional Stokes flow develops for stability reasons steady-state shapes whose edges from spindled become cusped with increasing flow rate owing to a transition of the edge tensions from tensile to compressive. A bifurcation in the steady-state shapes was also found (i.e. existence of both spindled and cusped edges for a range of high flow rates) by implementing different transient processes, owing to the different evolution of the membrane tensions. In this paper we show that the bifurcation range is wider at higher viscosity ratio (owing to the lower transient membrane tensions accompanied the slower capsule deformation starting from the quiescent capsule shape), while it contracts and eventually disappears as the viscosity ratio decreases. The spindle-to-cusp transition is shown to represent a self-similar finite-time singularity formation which for real capsules with very small but finite thickness is expected to be an apparent singularity, i.e. formation of very large (but finite) positive and negative edge curvatures.
Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.
Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M
2017-09-01
The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.
Purohit, Hitesh S; Trasi, Niraj S; Sun, Dajun D; Chow, Edwin C Y; Wen, Hong; Zhang, Xinyuan; Gao, Yi; Taylor, Lynne S
2018-05-01
Delivering a drug in amorphous form in a formulated product is a strategy used to enhance the apparent solubility of a drug substance and its oral bioavailability. Drug crystallization in such products may occur during the manufacturing process or on storage, reducing the solubility advantage of the amorphous drug. However, the impact of partial drug crystallization in the drug product on the resulting bioavailability and pharmacokinetics is unknown. In this study, dissolution testing of commercial tacrolimus capsules (which are formulated to contain amorphous drug), both fresh and those containing different amounts of crystalline drug, was conducted using both United States Pharmacopeia and noncompendial dissolution tests with different dissolution media and volumes. A physiologically based pharmacokinetic (PBPK) absorption model was developed to predict the impact of crystallinity extent on the oral absorption of the products and to evaluate the discriminatory ability of the different dissolution methods. Virtual bioequivalence simulations between partially crystallized tacrolimus capsules versus fresh Prograf or generic tacrolimus capsules were performed using the PBPK model and in vitro dissolution data of the various fresh and partially crystallized capsules under United States Pharmacopeia and noncompendial dissolution conditions. The results suggest that compendial dissolution tests may not be sufficiently discriminatory with respect to the presence of crystallinity in an amorphous formulation. Nonsink dissolution tests using lower dissolution volumes generate more discriminatory profiles that predict different pharmacokinetics of tacrolimus capsules containing different extents of drug crystallinity. In conclusion, the PBPK modeling approach can be used to assess the impact of partial drug crystallinity in the formulated product and to guide the development of appropriate dissolution methods. Copyright © 2018 American Pharmacists Association®. All rights reserved.
Williams, Hayley; Jones, Stephen; Wood, Kelly; Scott, Robert A H; Eddleston, Michael; Thomas, Simon H L; Thompson, John Paul; Vale, J Allister
2014-02-01
CONTEXT. Data on the ophthalmic and central nervous system (CNS) adverse effects of liquid detergent capsules (liquid laundry pods) are limited. OBJECTIVE. To ascertain the reported toxicity of liquid detergent capsules, particularly their ophthalmic and CNS adverse effects, in a large case series. METHODS. Between 1 May 2009 and 30 July 2012 the UK National Poisons Information Service collected prospectively 1509 telephone enquiries (involving 1486 exposures) relating to liquid detergent capsules. RESULTS. The majority of patients (95.6%) were children aged less than 5. Exposure to these products occurred mainly as a result of ingestion alone (n = 1215; 81.8%), with eye contact alone (n = 110; 7.4%), and skin contact alone (n = 20; 1.3%) being less common; multiple routes of exposure were involved in 141 (9.5%) cases. Following ocular exposure (n = 212), features suggesting conjunctivitis (n = 145; 68.4%) and corneal ulceration (n = 6; 2.8%) developed. The most common features reported following ingestion alone were nausea and vomiting (n = 721; 59.3%), followed by coughing (n = 53; 4.4%), drowsiness/CNS depression (n = 49; 42 of these were children were aged 2 years or less) and foaming at the mouth (n = 47; 3.9%). A rash occurred in 22 patients where ingestion was considered to be the route of exposure. Twenty patients were exposed via the dermal route alone and developed erythema (n = 9), rash (n = 6) and burn (n = 3). CONCLUSIONS. Ocular exposure to liquid detergent capsules may lead to conjunctivitis and corneal ulceration; detergent ingestion may result in central nervous system (CNS)depression. Greater consumer awareness is required to reduce injury from liquid detergent capsules, particularly that involving the eye.
[Application of microwave technology in extraction process of Guizhi Fuling capsule].
Wang, Zheng-kuan; Zhou, Mao; Liu, Yuan; Bi, Yu-an; Wang, Zhen-zhong; Xiao, Wei
2015-06-01
In this paper, optimization of the conditions of microwave technique in extraction process of Guizhi Fuling capsule in the condition of a pilot scale was carried out. First of all, through the single factor experiment investigation of various factors, the overall impact tendency and range of each factor were determined. Secondly, L9 (3(4)) orthogonal test optimization was used, and the contents of gallic acid in liquid, paeoniflorin, benzoic acid, cinnamic acid, benzoyl paeoniflorin, amygdalin of the liquid medicine were detected. The extraction rate and comprehensive evaluation were calculated with the extraction effect, as the judgment basis. Theoptimum extraction process of Guizhi Fuling capsule by microwave technology was as follows: the ratio of liquid to solid was 6: 1 added to drinking water, the microwave power was 6 kW, extraction time was 20 min for 3 times. The process of the three batch of amplification through verification, the results are stable, and compared with conventional water extraction has the advantages of energy saving, time saving, high efficiency advantages. The above results show the optimum extracting technology of high efficiency, stable and feasible.
USDA-ARS?s Scientific Manuscript database
Campylobacter jejuni produces a polysaccharide capsule that is the major determinant of the Penner serotyping scheme. This passive slide agglutination typing system was developed in the early 1980’s and was recognized for over two decades as gold standard for C. jejuni typing. A preliminary multiple...
Constraints on oxygen fugacity within metal capsules
NASA Astrophysics Data System (ADS)
Faul, Ulrich H.; Cline, Christopher J., II; Berry, Andrew; Jackson, Ian; Garapić, Gordana
2018-06-01
Experiments were conducted with olivine encapsulated or wrapped in five different metals (Pt, Ni, Ni_{70}Fe_{30}, Fe, and Re) to determine the oxygen fugacity in the interior of large capsules used for deformation and seismic property experiments. Temperature (1200°C), pressure (300 MPa), and duration (24 h) were chosen to represent the most common conditions in these experiments. The oxygen fugacity was determined by analysing the Fe content of initially pure Pt particles that were mixed with the olivine powder prior to the experiments. Oxygen fugacities in the more oxidizing metal containers are substantially below their respective metal-oxide buffers, with the fO_2 of sol-gel olivine in Ni about 2.5 orders of magnitude below Ni-NiO. Analysis of olivine and metal blebs reveals three different length-, and hence diffusive time scales: (1) Fe loss to the capsule over ˜ 100 μ m, (2) fO_2 gradients at the sample-capsule interface up to 2 mm into the sample, and (3) constant interior fO_2 values with an ordering corresponding to the capsule material. The inferred diffusive processes are: Fe diffusion in olivine with a diffusivity ˜ 10^{-14} m^2/s, diffusion possibly of oxygen along grain boundaries with a diffusivity ˜ 10^{-12} m^2/s, and diffusion possibly involving pre-existing defects with a diffusivity ˜ 10^{-10} m^2/s. The latter, fast adjustment to changing fO_2 may consist of a rearrangement of pre-existing defects, representing a metastable equilibrium, analogous to decoration of pre-existing defects by hydrogen. Full adjustment to the external fO_2 requires atomic diffusion.
Biocompatible Capsules and Methods of Making
NASA Technical Reports Server (NTRS)
Loftus, David J. (Inventor)
2017-01-01
Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.
Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm
2018-05-29
Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy. The new capsule polymerase family described here vastly increases the toolbox of enzymes available for biotechnology purposes. Representatives are abundantly found in human pathogens but also in animal pathogens, paving the way for the exploitation of polymerases for the development of a new generation of vaccines for animal husbandry. Copyright © 2018 Litschko et al.
Convergent ablation measurements of plastic ablators in gas-filled rugby hohlraums on OMEGA
NASA Astrophysics Data System (ADS)
Casner, A.; Jalinaud, T.; Masse, L.; Galmiche, D.
2015-10-01
Indirect-drive implosions experiments were conducted on the Omega Laser Facility to test the performance of uniformly doped plastic ablators for Inertial Confinement Fusion. The first convergent ablation measurements in gas-filled rugby hohlraums are reported. Ignition relevant limb velocities in the range from 150 to 300 μm .n s-1 have been reached by varying the laser drive energy and the initial capsule aspect ratio. The measured capsule trajectory and implosion velocity are in good agreement with 2D integrated simulations and a zero-dimensional modeling of the implosions. We demonstrate experimentally the scaling law for the maximum implosion velocity predicted by the improved rocket model [Y. Saillard, Nucl. Fusion 46, 1017 (2006)] in the high-ablation regime case.
2011-12-02
CAPE CANAVERAL, Fla. – NASA's Liberty Star ship heads into the Atlantic Ocean where tests will be performed on an Orion flight test capsule. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.
Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M
2010-03-01
Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathur, Anoop
2013-12-15
Terrafore successfully demonstrated and optimized the manufacturing of capsules containing phase-changing inorganic salts. The phase change was used to store thermal energy collected from a concentrating solar-power plant as latent heat. This latent heat, in addition to sensible heat increased the energy density (energy stored per unit weight of salt) by over 50%, thus requiring 40% less salt and over 60% less capsule container. Therefore, the cost to store high-temperature thermal energy collected in a concentrating solar power plant will be reduced by almost 40% or more, as compared to conventional two-tank, sensible-only storage systems. The cost for thermal energymore » storage (TES) system is expected to achieve the Sun Shot goal of $15 per kWh(t). Costs associated with poor heat-transfer in phase change materials (PCM) were also eliminated. Although thermal energy storage that relies on the latent heat of fusion of PCM improves energy density by as much as 50%, upon energy discharge the salt freezes and builds on the heat transfer surfaces. Since these salts have low thermal conductivity, large heat-transfer areas, or larger conventional heat-exchangers are needed, which increases costs. By encapsulating PCM in small capsules we have increased the heat transfer area per unit volume of salt and brought the heat transfer fluid in direct contact with the capsules. These two improvements have increased the heat transfer coefficient and boosted heat transfer. The program was successful in overcoming the phenomenon of melt expansion in the capsules, which requires the creation of open volume in the capsules or shell to allow for expansion of the molten salt on melting and is heated above its melting point to 550°C. Under contract with the Department of Energy, Terrafore Inc. and Southwest Research Institute, developed innovative method(s) to economically create the open volume or void in the capsule. One method consists of using a sacrificial polymer coating as the middle layer between the salt prill and the shell material. The selected polymer decomposes at temperatures below the melting point of the salt and forms gases which escape through the pores in the capsule shell thus leaving a void in the capsule. We have demonstrated the process with a commonly used inorganic nitrate salt in a low-cost shell material that can withstand over 10,000 high-temperature thermal cycles, or a thirty-year or greater life in a solar plant. The shell used to encapsulate the salt was demonstrated to be compatible with molten salt heat transfer fluid typically used in CSP plants to temperatures up to 600 °C. The above findings have led to the concept of a cascaded arrangement. Salts with different melting points can be encapsulated using the same recipe and contained in a packed bed by cascading the salt melting at higher melting point at the top over the salt melting at lower melting point towards the bottom of the tank. This cascaded energy storage is required to effectively transfer the sensible heat collected in heat transfer fluids between the operating temperatures and utilize the latent heat of fusion in the salts inside the capsule. Mathematical models indicate that over 90% of the salts will undergo phase change by using three salts in equal proportion. The salts are selected such that the salt at the top of the tank melts at about 15°C below the high operating-temperature, and the salt at the bottom of the tank melts 15°C above the low operating-temperature. The salt in the middle of tank melts in-between the operating temperature of the heat transfer fluid. A cascaded arrangement leads to the capture of 90% of the latent-heat of fusion of salts and their sensible heats. Thus the energy density is increased by over 50% from a sensible-only, two-tank thermal energy storage. Furthermore, the Terrafore cascaded storage method requires only one tank as opposed to the two-tanks used in sensible heat storage. Since heat is transferred from the heat transfer fluid by direct contact with capsules, external heat-exchangers are not required for charging storage. Thus, the cost of the thermal storage system is reduced due to smaller containers and less salt. The optimum salt proportions, their melting temperature and the number of salts in the cascade are determined by raw materials costs and the mathematical model. We estimate the processing cost of the encapsulation to be low, where the major cost of the capsule will be the cost of the phase-change salt(s). Our economic analyses show that the cost of EPCM-TES is about $17.98 per kWh(t), which is about 40% lower than the $28.36 per kWh(t) for a two-tank sensible heat TES for a large scale CSP-TES design. Finally, additional improvements in the heat-transfer fluids, currently in development elsewhere will further improve the energy density to achieve the SunShot goal of $15 per kWh(t).« less
Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.
Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L
2009-01-01
The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.
A comparative study on liquid core formulation on the diameter on the alginate capsules
NASA Astrophysics Data System (ADS)
Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng
2015-08-01
Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis
Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240
Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I
2010-06-01
Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Richert, Hendryk; Surzhenko, Oleksy; Wangemann, Sebastian; Heinrich, Jochen; Görnert, Peter
2005-05-01
A method for active drug delivery inside the human digestive system is proposed. This method allows the localisation of a magnetically marked capsule on its natural way through the digestive system and to open it at a desired position. Thus, the procedure contains two important components: the magnetic monitoring and active drug release.
Inflated Sporopollenin Exine Capsules Obtained from Thin-Walled Pollen
NASA Astrophysics Data System (ADS)
Park, Jae Hyeon; Seo, Jeongeun; Jackman, Joshua A.; Cho, Nam-Joon
2016-06-01
Sporopollenin is a physically robust and chemically resilient biopolymer that comprises the outermost layer of pollen walls and is the first line of defense against harsh environmental conditions. The unique physicochemical properties of sporopollenin increasingly motivate the extraction of sporopollenin exine capsules (SECs) from pollen walls as a renewable source of organic microcapsules for encapsulation applications. Despite the wide range of different pollen species with varying sizes and wall thicknesses, faithful extraction of pollen-mimetic SECs has been limited to thick-walled pollen capsules with rigid mechanical properties. There is an unmet need to develop methods for producing SECs from thin-walled pollen capsules which constitute a large fraction of all pollen species and have attractive materials properties such as greater aerosol dispersion. Herein, we report the first successful extraction of inflated SEC microcapsules from a thin-walled pollen species (Zea mays), thereby overcoming traditional challenges with mechanical stability and loss of microstructure. Morphological and compositional characterization of the SECs obtained by the newly developed extraction protocol confirms successful protein removal along with preservation of nanoscale architectural features. Looking forward, there is excellent potential to apply similar strategies across a wide range of unexplored thin-walled pollen species.
Surgical treatment of parapontine epidermoid cysts presenting with trigeminal neuralgia.
Guo, Zhilin; Ouyang, Huoniu; Cheng, Zhihua
2011-03-01
We retrospectively reviewed the management of 49 patients with parapontine epidermoid cyst presenting with trigeminal neuralgia, emphasizing the importance of fully removing the tumor to relieve the trigeminal neuralgia. Clinical symptoms, MRI, the operative approach, and post-operative results were examined. Trigeminal neuralgia was noted in all patients. The mean duration from onset of symptoms to surgery was 18 months. Total removal was achieved in 23 patients, near-total removal in 21, and subtotal removal in five patients. However, all tumor capsule that adhered to the trigeminal nerve was completely removed. After the operation, 33 patients developed facial hypoesthesia, three complained of double vision, and two developed acute hydrocephalus. At six months of follow-up, all patients had recovered and returned to their normal lives. At 2 years of follow-up, one patient experienced pain recurrence and underwent another operation. Parapontine epidermoid cysts either encase cranial nerve (CN) V but with intact arachnoid between the capsule and the nerve, or compress and distort the nerve with tumor capsule adherent or attached to the nerve surface. Resecting the tumor capsule's attachment to CN V is critical in relieving pain, even though this method may damage the nerve. Copyright © 2010 Elsevier Ltd. All rights reserved.
Jellyfish stinging is driven by the moving front of the nematocyst's tubule
NASA Astrophysics Data System (ADS)
Shavit, Uri; Park, Sinwook; Piriatinskiy, Gadi; Yossifon, Gilad; Lotan, Tamar
2017-11-01
Nematocysts are ultra-fast stinging organelles that are utilized by the Cnidaria phylum for prey capture, defense and locomotion. They consist of a capsule and a tubule and exert high pressure and acceleration to penetrate the target organism. Previous studies report that the ejection and elongation of the tubule are driven by a buildup of osmotic potential in the capsule. We question this explanation using a microfluidic system that controls the osmotic potential by directing the tubule through oil, where no osmotic potential can develop, while keeping the capsule in water. It was found that the time needed for elongation through oil is orders of magnitude larger than through water. Our mathematical model shows that the p γGlu concentration in the tubule is higher than in the capsule and the internal pressure that develops there serves as the elongation driving force. These findings imply that modifications of the environment along the tubule route have the potential to slow down the process and reduce its impact. This may shed light on prey defense strategies, human protection against jellyfish stinging, the use of nematocysts for drug delivery and exploration of osmotic based methods for nanotubes production and elongation.
Inflated Sporopollenin Exine Capsules Obtained from Thin-Walled Pollen
Park, Jae Hyeon; Seo, Jeongeun; Jackman, Joshua A.; Cho, Nam-Joon
2016-01-01
Sporopollenin is a physically robust and chemically resilient biopolymer that comprises the outermost layer of pollen walls and is the first line of defense against harsh environmental conditions. The unique physicochemical properties of sporopollenin increasingly motivate the extraction of sporopollenin exine capsules (SECs) from pollen walls as a renewable source of organic microcapsules for encapsulation applications. Despite the wide range of different pollen species with varying sizes and wall thicknesses, faithful extraction of pollen-mimetic SECs has been limited to thick-walled pollen capsules with rigid mechanical properties. There is an unmet need to develop methods for producing SECs from thin-walled pollen capsules which constitute a large fraction of all pollen species and have attractive materials properties such as greater aerosol dispersion. Herein, we report the first successful extraction of inflated SEC microcapsules from a thin-walled pollen species (Zea mays), thereby overcoming traditional challenges with mechanical stability and loss of microstructure. Morphological and compositional characterization of the SECs obtained by the newly developed extraction protocol confirms successful protein removal along with preservation of nanoscale architectural features. Looking forward, there is excellent potential to apply similar strategies across a wide range of unexplored thin-walled pollen species. PMID:27302853
Intestinal biomechanics simulator for robotic capsule endoscope validation.
Slawinski, Piotr R; Oleynikov, Dmitry; Terry, Benjamin S
2015-01-01
This work describes the development and validation of a novel device which simulates important forces experienced by Robotic Capsule Endoscopes (RCE) in vivo in the small intestine. The purpose of the device is to expedite and lower the cost of RCE development. Currently, there is no accurate in vitro test method nor apparatus to validate new RCE designs; therefore, RCEs are tested in vivo at a cost of ∼$1400 per swine test. The authors have developed an in vitro RCE testing device which generates two peristaltic waves to accurately simulate the two biomechanical actions of the human small intestine that are most relevant to RCE locomotion: traction force and contact force. The device was successfully calibrated to match human physiological ranges for traction force (4-40 gf), contact force (80-500 gf) and peristaltic wave propagation speed (0.08-2 cm s(-1)) for a common RCE capsule geometry of 3.5 cm length and 1.5 cm diameter.
Zhou, Chunhua; Su, Linfei; Shang, Weiding; Rong, Zhihuan; Sun, Mengmeng; Zhang, Kai; Shi, Xiaowei; Wang, Qiao
2015-01-01
A rapid, sensitive, selective and periodic polarity-switching liquid chromatography-tandem mass spectrometry(LC-MS-MS) method was developed for the simultaneous determination of eight components in an important traditional Chinese medicinal capsule, Fufang Xueshuantong. LC analysis was carried out on a Kinetex 2.6 µm XB-C18 column by gradient elution. The detection was performed by multiple reaction monitoring (MRM) with a periodic polarity-switching electrospray ionization (ESI) source across five periods of switching between positive and negative mode. Periodic polarity-switching was used to acquire maximal responses and to simultaneously detect eight constituents in one analysis run lasting 8 min. All of the analytes showed good linearity (r > 0.9947) in the tested ranges. The average recoveries were in the range of 95.4-103.9% with relative standard deviations ≤6.3%, and the intra- and inter-day variations were ≤3.7%. The developed method was successfully employed to analyze three batches of Fufang Xueshuantong capsule samples. The results showed that the levels of notoginsenoside R1, ginsenoside Rb1 and salvianolic acid B were clearly different in different batches of Fufang Xueshuantong capsules. Furthermore, the new established periodic polarity-switching LC-MS-MS method was proven to be highly sensitive and effective in evaluating the quality of Fufang Xueshuantong capsules. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.
Corrosion of 316 stainless steel in high temperature molten Li2BeF4 (FLiBe) salt
NASA Astrophysics Data System (ADS)
Zheng, Guiqiu; Kelleher, Brian; Cao, Guoping; Anderson, Mark; Allen, Todd; Sridharan, Kumar
2015-06-01
In support of structural material development for the fluoride-salt-cooled high-temperature reactor (FHR), corrosion tests of 316 stainless steel were performed in the potential primary coolant, molten Li2BeF4 (FLiBe) at 700 °C for an exposure duration up to 3000 h. Tests were performed in both 316 stainless steel and graphite capsules. Corrosion in both capsule materials occurred by the dissolution of chromium from the stainless steel into the salt which led to the depletion of chromium predominantly along the grain boundaries of the test samples. The samples tested in graphite capsules showed a factor of two greater depth of corrosion attack as measured in terms of chromium depletion, compared to those tested in 316 stainless steel capsules. The samples tested in graphite capsules showed the formation of Cr7C3 particulate phases throughout the depth of the corrosion layer. Samples tested in both types of capsule materials showed the formation of MoSi2 phase due to increased activity of Mo and Si as a result of Cr depletion, and furthermore corrosion promoted the formation of a α-ferrite phase in the near-surface regions of the 316 stainless steel. Based on the corrosion tests, the corrosion attack depth in FLiBe salt was predicted as 17.1 μm/year and 31.2 μm/year for 316 stainless steel tested in 316 stainless steel and in graphite capsules respectively. It is in an acceptable range compared to the Hastelloy-N corrosion in the Molten Salt Reactor Experiment (MSRE) fuel salt.
Mesa, Luz Estella; Vasquez, Daniel; Lutgen, Pierre; Vélez, Iván Darío; Restrepo, Adriana María; Ortiz, Isabel; Robledo, Sara María
2017-01-01
Cutaneous leishmaniasis (CL) is a tropical disease that affects millions of individuals worldwide. The current drugs for CL may be effective but have serious side effects; hence, alternatives are urgently needed. Although plant-derived materials are used for the treatment of various diseases in 80% of the global population, the validation of these products is essential. Gelatin capsules containing dried Artemisia annua leaf powder were recently developed as a new herbal formulation (totum) for the oral treatment of malaria and other parasitic diseases. Here, we aimed to determine the usefulness of A. annua gel capsules in CL. The antileishmanial activity and cytotoxicity of A. annua L. capsules was determined via in vitro and in vivo studies. Moreover, a preliminary evaluation of its therapeutic potential as antileishmanial treatment in humans was conducted in 2 patients with uncomplicated CL. Artemisia annua capsules showed moderate in vitro activity in amastigotes of Leishmania (Viannia) panamensis; no cytotoxicity in U-937 macrophages or genotoxicity in human lymphocytes was observed. Five of 6 (83.3%) hamsters treated with A. annua capsules (500mg/kg/day) for 30 days were cured, and the 2 examined patients were cured 45 days after initiation of treatment with 30g of A. annua capsules, without any adverse reactions. Both patients remained disease-free 26 and 24 months after treatment completion. Capsules of A. annua L. represent an effective treatment for uncomplicated CL, although further randomized controlled trials are needed to validate its efficacy and safety.
Conceptual design of initial opacity experiments on the national ignition facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeter, R. F.; Bailey, J. E.; Craxton, R. S.
Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperaturesmore » $${\\geqslant}150$$ eV and electron densities$${\\geqslant}7\\times 10^{21}~\\text{cm}^{-3}$$. The iron will be probed using continuum X-rays emitted in a$${\\sim}200$$ ps,$${\\sim}200~\\unicode[STIX]{x03BC}\\text{m}$$diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design,$2/3$$of the NIF beams deliver 500 kJ to the$${\\sim}6$$ mm diameter hohlraum, and the remaining$$1/3$directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.« less
Glass, Torin J A; Chau, Vann; Gardiner, Jane; Foong, Justin; Vinall, Jillian; Zwicker, Jill G; Grunau, Ruth E; Synnes, Anne; Poskitt, Kenneth J; Miller, Steven P
2017-11-01
To determine whether severe retinopathy of prematurity (ROP) is associated with (1) abnormal white matter maturation and (2) neurodevelopmental outcomes at 18 months' corrected age (CA) compared with neonates without severe ROP. We conducted a prospective longitudinal cohort of extremely preterm neonates born 24-28 weeks' gestational age recruited between 2006 and 2013 with brain MRIs obtained both early in life and at term-equivalent age. Severe ROP was defined as ROP treated with retinal laser photocoagulation. Using diffusion tensor imaging and tract-based spatial statistics (TBSS), white matter maturation was assessed by mean fractional anisotropy (FA) in seven predefined regions of interest. Neurodevelopmental outcomes were assessed with Bayley Scales of Infant and Toddler Development-III (Bayley-III) composite scores at 18 months' CA. Subjects were compared using Fisher's exact, Kruskal-Wallis and generalised estimating equations. Families were recruited from the neonatal intensive care unit at BC Women's Hospital. Of 98 extremely preterm neonates (median: 26.0 weeks) assessed locally for ROP, 19 (19%) had severe ROP and 83 (85%) were assessed at 18 months' CA. Severe ROP was associated with lower FA in the posterior white matter, and with decreased measures of brain maturation in the optic radiations, posterior limb of the internal capsule (PLIC) and external capsule on TBSS. Bayley-III cognitive and motor scores were lower in infants with severe ROP. Severe ROP is associated with maturational delay in the optic radiations, PLIC, external capsule and posterior white matter, housing the primary visual and motor pathways, and is associated with poorer cognitive and motor outcomes at 18 months' CA. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Matsuura, Mizue; Inamori, Masahiko; Inou, Yumi; Kanoshima, Kenji; Higurashi, Takuma; Ohkubo, Hidenori; Iida, Hiroshi; Endo, Hiroki; Nonaka, Takashi; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi
2017-06-01
Lubiprostone has been reported to be an anti-constipation drug. The aim of the study was to investigate the usefulness of lubiprostone both for bowel preparation and as a propulsive agent in small bowel endoscopy. This was a double-blind, placebo-controlled, 2-way crossover study of subjects who volunteered to undergo capsule endoscopy (CE). A total of 20 subjects (16 male and 4 female volunteers) were randomly assigned to receive a 24-μg tablet of lubiprostone 120 minutes prior to capsule ingestion for CE (L regimen), or a placebo tablet 120 minutes prior to capsule ingestion for CE (P regimen). Main outcome was gastric transit time (GTT) and small-bowel transit time (SBTT). Secondary outcome was adequacy of small-bowel cleansing and the fluid score in the small bowel. The quality of the capsule endoscopic images and fluid in the small bowel were assessed on 5-point scale. The capsule passed into the small bowel in all cases. Median GTT was 57.3 (3 - 221) minutes for the P regimen and 61.3 (10 - 218) minutes for the L regimen ( P = 0.836). Median SBTT was 245.0 (164 - 353) minutes for the P regimen and 228.05 (116 - 502) minutes for the L regimen ( P = 0.501). The image quality score in the small bowel was 3.05 ± 1.08 for the P regimen and 3.80 ± 0.49 for the L regimen ( P < 0.001). The fluid score in the small bowel was 2.04 ± 1.58 for the P regimen and 2.72 ± 1.43 for the L regimen ( P < 0.001). There was a significant difference between the 2 regimens with regard to image quality. The fluid score was more plentiful for the L regimen than for the P regimen. There were no cases of capsule retention or serious adverse events in this study. Our study showed that use of lubiprostone prior to CE significantly improved visualization of the small bowel during CE as a result of inducing fluid secretion into the small bowel.
Development of the prototype pneumatic transfer system for ITER neutron activation system.
Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L
2012-10-01
The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.
Xu, Fei; Yan, Guozheng; Zhao, Kai; Lu, Li; Gao, Jinyang; Liu, Gang
2014-12-01
This paper presents the design of a wireless capsule system for monitoring the physiological signals of the human gastrointestinal (GI) tract. The primary components of the system include a wireless capsule, a portable data recorder, and a workstation. Temperature, pH, and pressure sensors; an RF transceiver; a controlling and processing application specific integrated circuit (ASIC); and batteries were applied in a wireless capsule. Decreasing capsule size, improving sensor precision, and reducing power needs were the primary challenges; these were resolved by employing micro sensors, optimized architecture, and an ASIC design that include power management, clock management, a programmable gain amplifier (PGA), an A/D converter (ADC), and a serial peripheral interface (SPI) communication unit. The ASIC has been fabricated in 0.18- μm CMOS technology with a die area of 5.0 mm × 5.0 mm. The wireless capsule integrating the ASIC controller measures Φ 11 mm × 26 mm. A data recorder and a workstation were developed, and 20 cases of human experiments were conducted in hospitals. Preprocessing in the workstation can significantly improve the quality of the data, and 76 original features were determined by mathematical statistics. Based on the 13 optimal features achieved in the evaluation of the features, the clustering algorithm can identify the patients who lack GI motility with a recognition rate reaching 83.3%.
Chong, Siow-Feng; Sexton, Amy; De Rose, Robert; Kent, Stephen J; Zelikin, Alexander N; Caruso, Frank
2009-10-01
We report on the use of degradable polymer capsules as carriers for the delivery of oligopeptide antigens to professional antigen presenting cells (APCs). To achieve encapsulation, oligopeptide sequences were covalently linked to a negatively charged carrier polymer via biodegradable linkages and the resulting conjugate was then adsorbed onto amine-functionalized silica particles. These peptide-coated particles were then used as templates for the layer-by-layer (LbL) deposition of thiolated poly(methacrylic acid) (PMA(SH)) and poly(vinylpyrrolidone) (PVPON) multilayers. Removal of the silica core and disruption of the hydrogen bonding between PMA(SH) and PVPON by altering the solution pH yielded disulfide-stabilized PMA capsules that retain the encapsulated cargo in an oxidative environment. In the presence of a natural reducing agent, glutathione, cleavage of the disulfide bonds causes release of the peptide from the capsules. The developed strategy provides control over peptide loading into polymer capsules and yields colloidally stable micron- and submicron-sized carriers with uniform size and peptide loading. The conjugation and encapsulation procedures were proven to be non-degrading to the peptide vaccines. The peptide-loaded capsules were successfully used to deliver their cargo to APCs and activate CD8 T lymphocytes in a non-human primate model of SIV infection ex vivo. The reported approach represents a novel paradigm in the delivery of peptide vaccines and other therapeutic agents.
An empirical study of the toxic capsule crisis in China: risk perceptions and behavioral responses.
Feng, Tianjun; Keller, L Robin; Wu, Ping; Xu, Yifan
2014-04-01
The outbreak of the toxic capsule crisis during April 2012 aroused widespread public concern about the risk of chromium-contaminated capsules and drug safety in China. In this article, we develop a conceptual model to investigate risk perceptions of the pharmaceutical drug capsules and behavioral responses to the toxic capsule crisis and the relationship between associated factors and these two variables. An online survey was conducted to test the model, including questions on the measures of perceived efficacy of the countermeasures, trust in the State FDA (Food and Drug Administration), trust in the pharmaceutical companies, trust in the pharmaceutical capsule producers, risk perception, concern, need for information, information seeking, and risk avoidance. In general, participants reported higher levels of risk perception, concern, and risk avoidance, and lower levels of trust in the three different stakeholders. The results from the structural equation modeling procedure suggest that perceived efficacy of the countermeasures is a predictor of each of the three trust variables; however, only trust in the State FDA has a dampening impact on risk perception. Both risk perception and information seeking are significant determinants of risk avoidance. Risk perception is also positively related to concern. Information seeking is positively related to both concern and need for information. The theoretical and policy implications are also discussed. © 2013 Society for Risk Analysis.
Liang, Xing; Kozlovskaya, Veronika; Chen, Yi; Zavgorodnya, Oleksandra; Kharlampieva, Eugenia
2012-08-09
We report on nanothin multilayer hydrogels of cross-linked poly(N-vinylcaprolactam) (PVCL) that exhibit distinctive and reversible thermoresponsive behavior. The single-component PVCL hydrogels were produced by selective cross-linking of PVCL in layer-by-layer films of PVCL-NH(2) copolymers assembled with poly(methacrylic acid) (PMAA) via hydrogen bonding. The degree of the PVCL hydrogel film shrinkage, defined as the ratio of wet thicknesses at 25°C to 50°C, was demonstrated to be 1.9±0.1 and 1.3±0.1 for the films made from PVCL-NH(2)-7 and PVCL-NH(2)-14 copolymers, respectively. No temperature-responsive behavior was observed for non-cross-linked two-component films due to the presence of PMAA. We also demonstrated that temperature-sensitive PVCL capsules of cubical and spherical shapes could be fabricated as hollow hydrogel replicas of inorganic templates. The cubical (PVCL)(7) capsules retained their cubical shape when temperature was elevated from 25°C to 50°C exhibiting 21±1% decrease in the capsule size. Spherical hydrogel capsules demonstrated similar shrinkage of 23±1%. The temperature-triggered capsule size changes were completely reversible. Our work opens new prospects for developing biocompatible and nanothin hydrogel-based coatings and containers for temperate-regulating drug delivery, cellular uptake, sensing, and transport behavior in microfluidic devices.
Increased Risk for Adhesive Capsulitis of the Shoulder following Cervical Disc Surgery.
Kang, Jiunn-Horng; Lin, Herng-Ching; Tsai, Ming-Chieh; Chung, Shiu-Dong
2016-05-27
Shoulder problems are common in patients with a cervical herniated intervertebral disc (HIVD). This study aimed to explore the incidence and risk of shoulder capsulitis/tendonitis following cervical HIVD surgery. We used data from the Taiwan "Longitudinal Health Insurance Database". We identified all patients who were hospitalized with a diagnosis of displacement of a cervical HIVD and who underwent cervical surgery (n = 1625). We selected 8125 patients who received cervical HIVD conservative therapy only as the comparison group matched with study patients. We individually tracked these sampled patients for 6 months to identify all patients who received a diagnosis of shoulder tendonitis/capsulitis. We found that incidence rates of shoulder tendonitis/capsulitis during the 6-month follow-up period were 3.69 (95% CI: 2.49~5.27) per 100 person-years for the study group and 2.33 (95% CI: 1.89~2.86) per 100 person-years for the comparison group. Cox proportional hazard regressions showed that the adjusted hazard ratio for shoulder tendonitis/capsulitis among patients who underwent cervical disc surgery was 1.66 (95% CI = 1.09~2.53) when compared to comparison group. We concluded that patients who underwent surgery for a cervical HIVD had a significantly higher risk of developing shoulder capsulitis/tendonitis in 6 months follow-up compared to patients who received cervical HIVD conservative therapy only.
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µm) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis. PMID:29686931
Valavala, Sriram; Seelam, Nareshvarma; Tondepu, Subbaiah; Jagarlapudi, V Shanmukha Kumar; Sundarmurthy, Vivekanandan
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µ m) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis.
Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...
Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa
2011-07-01
Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin bioavailability in the fed state is largely (and probably entirely) due to gastric degradation to DCA. Capsules can provide a useful and elegant dosage form for almost all drugs, but may result in a negative food effect for drugs as acid-labile as azithromycin.
NASA Technical Reports Server (NTRS)
Blanchard, R. C.; Walberg, G. D.
1980-01-01
Results of an investigation to determine the full scale drag coefficient in the high speed, low density regime of the Viking lander capsule 1 entry vehicle are presented. The principal flight data used in the study were from onboard pressure, mass spectrometer, and accelerometer instrumentation. The hypersonic continuum flow drag coefficient was unambiguously obtained from pressure and accelerometer data; the free molecule flow drag coefficient was indirectly estimated from accelerometer and mass spectrometer data; the slip flow drag coefficient variation was obtained from an appropriate scaling of existing experimental sphere data. Comparison of the flight derived drag hypersonic continuum flow regime except for Reynolds numbers from 1000 to 100,000, for which an unaccountable difference between flight and ground test data of about 8% existed. The flight derived drag coefficients in the free molecule flow regime were considerably larger than those previously calculated with classical theory. The general character of the previously determined temperature profile was not changed appreciably by the results of this investigation; however, a slightly more symmetrical temperature variation at the highest altitudes was obtained.
2008-04-01
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-04-01
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-03-29
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-03-28
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-03-29
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-03-29
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
Carillon, Julie; Notin, Claire; Schmitt, Karine; Simoneau, Guy; Lacan, Dominique
2014-06-19
We aimed to investigate effects of superoxide dismutase (SOD)-melon concentrate supplementation on psychological stress, physical and mental fatigue in healthy people. A randomized, double-blind, placebo-controlled trial was performed on 61 people divided in two groups: active supplement (n = 32) and placebo (n = 29) for 12 weeks. Volunteers were given one small hard capsule per day. One capsule contained 10 mg of SOD-melon concentrate (140 U of SOD) and starch for the active supplement and starch only for the placebo. Stress and fatigue were evaluated using four psychometric scales: PSS-14; SF-36; Stroop tests and Prevost scale. The supplementation with SOD-melon concentrate significantly decreased perceived stress, compared to placebo. Moreover, quality of life was improved and physical and mental fatigue were reduced with SOD-melon concentrate supplementation. SOD-melon concentrate supplementation appears to be an effective and natural way to reduce stress and fatigue. trial approved by the ethical committee of Poitiers (France), and the ClinicalTrials.gov Identifier is NCT01767922.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, L. J.; Logan, B. G.; Zimmerman, G. B.
2013-07-15
We report for the first time on full 2-D radiation-hydrodynamic implosion simulations that explore the impact of highly compressed imposed magnetic fields on the ignition and burn of perturbed spherical implosions of ignition-scale cryogenic capsules. Using perturbations that highly convolute the cold fuel boundary of the hotspot and prevent ignition without applied fields, we impose initial axial seed fields of 20–100 T (potentially attainable using present experimental methods) that compress to greater than 4 × 10{sup 4} T (400 MG) under implosion, thereby relaxing hotspot areal densities and pressures required for ignition and propagating burn by ∼50%. The compressed fieldmore » is high enough to suppress transverse electron heat conduction, and to allow alphas to couple energy into the hotspot even when highly deformed by large low-mode amplitudes. This might permit the recovery of ignition, or at least significant alpha particle heating, in submarginal capsules that would otherwise fail because of adverse hydrodynamic instabilities.« less
NASA Astrophysics Data System (ADS)
Fauzan Zakki, Ahmad; Suharto; Windyandari, Aulia
2018-03-01
Several attempts have been made to reduce the risk of tsunami disasters such as the development of early warning systems, evacuation procedures training, coastal protection and coastal spatial planning. Although many efforts to mitigate the impact of the tsunami in Indonesia was made, no one has developed a portable disaster rescue vehicle/shelter as well as a lifeboat on ships and offshore building, which is always available when a disaster occurs. The aim of the paper is to evaluate the performance of cone capsule shaped hull form that would be used for the portable tsunami lifeboat. The investigation of the boat resistance, intact stability, and seakeeping characteristics was made. The numerical analysis results indicate that the cone capsule is reliable as an alternative hull form for the portable tsunami lifeboat.
Liquid-liquid interfacial nanoparticle assemblies
Emrick, Todd S [South Deerfield, MA; Russell, Thomas P [Amherst, MA; Dinsmore, Anthony [Amherst, MA; Skaff, Habib [Amherst, MA; Lin, Yao [Amherst, MA
2008-12-30
Self-assembly of nanoparticles at the interface between two fluids, and methods to control such self-assembly process, e.g., the surface density of particles assembling at the interface; to utilize the assembled nanoparticles and their ligands in fabrication of capsules, where the elastic properties of the capsules can be varied from soft to tough; to develop capsules with well-defined porosities for ultimate use as delivery systems; and to develop chemistries whereby multiple ligands or ligands with multiple functionalities can be attached to the nanoparticles to promote the interfacial segregation and assembly of the nanoparticles. Certain embodiments use cadmium selenide (CdSe) nanoparticles, since the photoluminescence of the particles provides a convenient means by which the spatial location and organization of the particles can be probed. However, the systems and methodologies presented here are general and can, with suitable modification of the chemistries, be adapted to any type of nanoparticle.
2011-12-02
CAPE CANAVERAL, Fla. – Workers, on the deck of NASA's Liberty Star ship and in a boat in the Atlantic Ocean, prepare to begin testing of an Orion flight test capsule. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Workers on the deck of NASA's Liberty Star ship prepare for testing in the Atlantic Ocean of an Orion flight test capsule to begin. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Testing is under way on an Orion flight test capsule in the Atlantic Ocean. The tests are being monitored by workers aboard NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – An Orion flight test capsule aboard the deck of NASA's Liberty Star ship is moments away from being pulled overboard into the Atlantic Ocean. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Workers on the deck of NASA's Liberty Star ship prepare for testing in the Atlantic Ocean of an Orion flight test capsule to begin. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Testing is under way on an Orion flight test capsule in the Atlantic Ocean. The tests are being monitored by workers aboard NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – An Orion flight test capsule makes a splash into the Atlantic Ocean as it slides from the deck of NASA's Liberty Star ship into the water. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Rawlings, T A
1990-12-01
Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.
Neuroanatomical distribution of mechanoreceptors in the human cadaveric shoulder capsule and labrum
Witherspoon, Jessica W; Smirnova, Irina V; McIff, Terence E
2014-01-01
The distribution, location, and spatial arrangement of mechanoreceptors are important for neural signal conciseness and accuracy in proprioceptive information required to maintain functional joint stability. The glenohumeral joint capsule and labrum are mechanoreceptor-containing tissues for which the distribution of mechanoreceptors has not been determined despite the importance of these tissues in stabilizing the shoulder. More recently, it has been shown that damage to articular mechanoreceptors can result in proprioceptive deficits that may lead to recurrent instability. Awareness of mechanoreceptor distribution in the glenohumeral joint capsule and labrum may allow preservation of the mechanoreceptors during surgical treatment for shoulder instability, and in turn retain the joint's proprioceptive integrity. For this reason, we sought to develop a neuroanatomical map of the mechanoreceptors within the capsule and labrum. We postulated that the mechanoreceptors in these tissues are distributed in a unique pattern, with mechanoreceptor-scarce regions that may be more appropriate for surgical dissection. We determined the neuroanatomical distribution of mechanoreceptors and their associated fascicles in the capsule and labrum from eight human cadaver shoulder pairs using our improved gold chloride staining technique and light microscopy. A distribution pattern was consistently observed in the capsule and labrum from which we derived a neuroanatomical map. Both tissues demonstrated mechanoreceptor-dense and -scarce regions that may be considered during surgical treatment for instability. Capsular fascicles were located in the subsynovial layer, whereas labral fascicles were concentrated in the peri-core zone. The capsular fascicles presented as a lattice network and with a plexiform appearance. Fascicles within the labrum resembled a cable structure with the fascicles running in parallel. Our findings contribute to the neuroanatomical knowledge of the two glenohumeral joint stabilizers, namely, capsule and labrum, primarily involved in the onset of shoulder instability and recurrent instability. Neuroanatomical knowledge of articular mechanoreceptors is important for (i) developing a topographical map that reflects correspondence between the joint and surrounding musculature, (ii) understanding proprioceptive deficits that are only partially restored post surgical and post rehabilitative treatment, and (iii) gaining further knowledge about articular mechanoreceptors. PMID:25040358
Comparing Simulated and Observed Spectroscopic Signatures of Mix in Omega Capsules
NASA Astrophysics Data System (ADS)
Tregillis, I. L.; Shah, R. C.; Hakel, P.; Cobble, J. A.; Murphy, T. J.; Krasheninnikova, N. S.; Hsu, S. C.; Bradley, P. A.; Schmitt, M. J.; Batha, S. H.; Mancini, R. C.
2012-10-01
The Defect-Induced Mix Experiment (DIME) campaign at Los Alamos National Laboratory uses multi-monochromatic X-ray imaging (MMI)footnotetextT. Nagayama, R.C. Mancini, R. Florido, et al, J. App. Phys. 109, 093303 (2011) to detect the migration of high-Z spectroscopic dopants into the hot core of an imploded capsule. We have developed an MMI post-processing tool for producing synthetic datasets from two- and three-dimensional Lagrangian numerical simulations of Omega and NIF shots. These synthetic datasets are of sufficient quality, and contain sufficient physics, that they can be analyzed in the same manner as actual MMI data. We have carried out an extensive comparison between simulated and observed MMI data for a series of polar direct-drive shots carried out at the Omega laser facility in January, 2011. The capsule diameter was 870 microns; the 15 micron CH ablators contained a 2 micron Ti-doped layer along the inner edge. All capsules were driven with 17 kJ; some capsules were manufactured with an equatorial ``trench'' defect. This talk will focus on the construction of spectroscopic-quality synthetic MMI datasets from numerical simulations, and their correlation with MMI measurements.
Planarization of Isolated Defects on ICF Target Capsule Surfaces by Pulsed Laser Ablation
Alfonso, Noel; Carlson, Lane C.; Bunn, Thomas L.
2016-08-09
Demanding surface quality requirements for inertial confinement fusion (ICF) capsules motivated the development of a pulsed laser ablation method to reduce or eliminate undesirable surface defects. The pulsed laser ablation technique takes advantage of a full surface (4π) capsule manipulation system working in combination with an optical profiling (confocal) microscope. Based on the defect topography, the material removal rate, the laser pulse energy and its beam profile, a customized laser raster pattern is derived to remove the defect. The pattern is a table of coordinates and number of pulses that dictate how the defect will be vaporized until its heightmore » is level with the capsule surface. This paper explains how the raster patterns are optimized to minimize surface roughness and how surface roughness after laser ablation is simulated. The simulated surfaces are compared with actual ablated surfaces. Large defects are reduced to a size regime where a tumble finishing process produces very high quality surfaces devoid of high mode defects. The combined polishing processes of laser ablation and tumble finishing have become routine fabrication steps for National Ignition Facility capsule production.« less
Pneumococcal Capsules and Their Types: Past, Present, and Future
Geno, K. Aaron; Gilbert, Gwendolyn L.; Song, Joon Young; Skovsted, Ian C.; Klugman, Keith P.; Jones, Christopher; Konradsen, Helle B.
2015-01-01
SUMMARY Streptococcus pneumoniae (the pneumococcus) is an important human pathogen. Its virulence is largely due to its polysaccharide capsule, which shields it from the host immune system, and because of this, the capsule has been extensively studied. Studies of the capsule led to the identification of DNA as the genetic material, identification of many different capsular serotypes, and identification of the serotype-specific nature of protection by adaptive immunity. Recent studies have led to the determination of capsular polysaccharide structures for many serotypes using advanced analytical technologies, complete elucidation of genetic basis for the capsular types, and the development of highly effective pneumococcal conjugate vaccines. Conjugate vaccine use has altered the serotype distribution by either serotype replacement or switching, and this has increased the need to serotype pneumococci. Due to great advances in molecular technologies and our understanding of the pneumococcal genome, molecular approaches have become powerful tools to predict pneumococcal serotypes. In addition, more-precise and -efficient serotyping methods that directly detect polysaccharide structures are emerging. These improvements in our capabilities will greatly enhance future investigations of pneumococcal epidemiology and diseases and the biology of colonization and innate immunity to pneumococcal capsules. PMID:26085553
Pneumococcal Capsules and Their Types: Past, Present, and Future.
Geno, K Aaron; Gilbert, Gwendolyn L; Song, Joon Young; Skovsted, Ian C; Klugman, Keith P; Jones, Christopher; Konradsen, Helle B; Nahm, Moon H
2015-07-01
Streptococcus pneumoniae (the pneumococcus) is an important human pathogen. Its virulence is largely due to its polysaccharide capsule, which shields it from the host immune system, and because of this, the capsule has been extensively studied. Studies of the capsule led to the identification of DNA as the genetic material, identification of many different capsular serotypes, and identification of the serotype-specific nature of protection by adaptive immunity. Recent studies have led to the determination of capsular polysaccharide structures for many serotypes using advanced analytical technologies, complete elucidation of genetic basis for the capsular types, and the development of highly effective pneumococcal conjugate vaccines. Conjugate vaccine use has altered the serotype distribution by either serotype replacement or switching, and this has increased the need to serotype pneumococci. Due to great advances in molecular technologies and our understanding of the pneumococcal genome, molecular approaches have become powerful tools to predict pneumococcal serotypes. In addition, more-precise and -efficient serotyping methods that directly detect polysaccharide structures are emerging. These improvements in our capabilities will greatly enhance future investigations of pneumococcal epidemiology and diseases and the biology of colonization and innate immunity to pneumococcal capsules. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
NASA Technical Reports Server (NTRS)
Muniz, Beau
2009-01-01
One unique project that the Prototype lab worked on was PORT I (Post-landing Orion Recovery Test). PORT is designed to test and develop the system and components needed to recover the Orion capsule once it splashes down in the ocean. PORT II is designated as a follow up to PORT I that will utilize a mock up pressure vessel that is spatially compar able to the final Orion capsule.
Encapsulated Decon for Use on Medical Patients
1983-12-01
Development of effective decon microcapsules was based on a series of tasks performed on this study. The preliminary tasks included a litera- ture search...culminated with evaluating selected microcapsules on pig skin samples, with HD, GB, arid GD. Results appear encouraging. The best capsule performance...term contact. in addition, a brief study showed magnetite can be incorporated into the capsule wall to provide magnetic microcapsules that can be
Small bowel endoluminal imaging (capsule and enteroscopy).
Murino, Alberto; Despott, Edward J
2017-04-01
Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice.
1961-01-01
Ham, a three-year-old chimpanzee, in the spacesuit he would wear for the second Mercury- Redstone (MR-2) suborbital test flight in January, 1961. NASA used chimpanzees and other primates to test the Mercury capsule before launching the fisrt American astronaut, Alan Shepard, in May 1961. The Mercury capsule rode atop a modified Redstone rocket, developed by Dr. Wernher von Braun and the German Rocket Team in Huntsville, Alabama.
NASA Technical Reports Server (NTRS)
1961-01-01
Ham, a three-year-old chimpanzee, in the spacesuit he would wear for the second Mercury- Redstone (MR-2) suborbital test flight in January, 1961. NASA used chimpanzees and other primates to test the Mercury capsule before launching the fisrt American astronaut, Alan Shepard, in May 1961. The Mercury capsule rode atop a modified Redstone rocket, developed by Dr. Wernher von Braun and the German Rocket Team in Huntsville, Alabama.
Dissolution enhancement of atorvastatin calcium by co-grinding technique.
Prabhu, Priyanka; Patravale, Vandana
2016-08-01
Atorvastatin calcium (AC) is a BCS class II drug which shows poor bioavailability due to inadequate dissolution. Solid dispersions present a promising option to enhance the solubility of poorly soluble drugs. Co-grinding with hydrophilic excipients is an easy and economical technique to improve the solubility of poorly soluble drugs and is free from usage of organic solvents. The aim of the present study was to explore novel carrier VBP-1 (organosulphur compound) for formulating a solid dispersion by using a simple, commercially viable co-grinding technique to enhance the dissolution of AC and to develop an oral formulation of the same. Composition of the solid dispersion was optimized based on the release profile in pH 1.2 buffer. The optimized solid dispersion was further characterized for flow properties, DSC, FTIR spectroscopy, XRD, contact angle, SEM studies and release profile in phosphate buffer pH 6.8. The developed solid dispersion gave similar release profile as the innovator formulation (Lipitor® tablets) in both pH 1.2 buffer and phosphate buffer pH 6.8. The developed solid dispersion was formulated into hard gelatin capsules (size 3). The developed capsules were found to give similar release as the innovator formulation in both pH 1.2 buffer and phosphate buffer pH 6.8. The developed capsules were found to be stable for a period of 6 months. Anti-hyperlipidemic efficacy studies in rats showed higher reduction in cholesterol and triglyceride levels by the developed capsules in comparison to pure AC. In conclusion, novel carrier VBP-1 was successfully employed to enhance the dissolution of AC using co-grinding technique.
NASA Astrophysics Data System (ADS)
Petrasso, Richard D.
1997-01-01
Tertiary protons with birth energies from ˜27 to 30.8 MeV result from the implosion of ignition-scale inertial confinement fusion targets, such as those planned for the National Ignition Facility (NIF). Measurement of the tertiaries' slowing can provide a determination of the imploded areal density of the fuel capsule, as well as implosion asymmetry that results from anisotropy of the areal density and plasma temperature. In order to determine the utility of tertiaries for all phases of the NIF, we analyze three representative cases: a gas capsule (0.7 kJ yield); a cryogenic fuel capsule that fails to ignite (15 kJ); and a cryogenic fuel capsule that ignites and burns (13 000 kJ). In each case, tertiaries escape from the capsule and convey critical information about implosion dynamics. In addition, we show that for some gas-capsule implosions anticipated on OMEGA, tertiaries may be the only species of energetic charged particles that can determine the fuel areal density. Presently, we are building a charge-coupled device (CCD)-based charged particle spectrometer for OMEGA and for NOVA. In addition to the tertiaries, the spectrometers are sensitive to a variety of the energetic charged particles, such as knock-on protons, deuterons, and tritons, and 3He-burnup protons. In fact the latter set of charged particles will usually be the dominant signal. We will describe the basic features of the spectrometers and the measured response of the CCDs to 1-5 MeV protons, 1-5 MeV alphas, and 14 MeV neutrons (and associated gammas), the latter constitute the principal source of noise. This work is done in collaboration with C. K. Li, D. Hicks, and F. Seguin of MIT; with B. Burke of LL/MIT; with M. Cable, S. Pollaine, S. Haan, T. Bernat, T. Phillips, and J. Kilkenny of LLNL; with J, Knauer, S. Cremer, C. Verdon, and B. Kremens of University of Rochester; and with C. Ruiz and R. Leeper of SNL. This work is supported in part by LLNL Subcontract B313875 and University of Rochester Subcontract 410025-G.
Huang, Renliang; Wu, Mengyun; Goldman, Mark J; Li, Zhi
2015-06-01
Enzyme encapsulation is a simple, gentle, and general method for immobilizing enzyme, but it often suffers from one or more problems regarding enzyme loading efficiency, enzyme leakage, mechanical stability, and recyclability. Here we report a novel, simple, and efficient method for enzyme encapsulation to overcome these problems by forming stable organic-inorganic hybrid capsules. A new, facile, one-step, and template-free synthesis of organic-inorganic capsules in aqueous phase were developed based on PEI-induced simultaneous interfacial self-assembly of Fmoc-FF and polycondensation of silicate. Addition of an aqueous solution of Fmoc-FF and sodium silicate into an aqueous solution of PEI gave a new class of organic-inorganic hybrid capsules (FPSi) with multi-layered structure in high yield. The capsules are mechanically stable due to the incorporation of inorganic silica. Direct encapsulation of enzyme such as epoxide hydrolase SpEH and BSA along with the formation of the organic-inorganic capsules gave high yield of enzyme-containing capsules (∼1.2 mm in diameter), >90% enzyme loading efficiency, high specific enzyme loading (158 mg protein g(-1) carrier), and low enzyme leakage (<3% after 48 h incubation). FPSi-SpEH capsules catalyzed the hydrolysis of cyclohexene oxide to give (1R, 2R)-cyclohexane-1,2-diol in high yield and concentration, with high specific activity (6.94 U mg(-1) protein) and the same high enantioselectivity as the free enzyme. The immobilized SpEH demonstrated also excellent operational stability and recyclability: retaining 87% productivity after 20 cycles with a total reaction time of 80 h. The new enzyme encapsulation method is efficient, practical, and also better than other reported encapsulation methods. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.
Hydrodynamic instability growth of the capsule support membranes (or “tents”) and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF). In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new “sub-scale” version of the existing x-ray radiography platform wasmore » developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ~2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ~3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. In conclusion, the effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.« less
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.; ...
2017-10-20
Hydrodynamic instability growth of the capsule support membranes (or “tents”) and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF). In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new “sub-scale” version of the existing x-ray radiography platform wasmore » developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ~2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ~3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. In conclusion, the effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.« less
Capsule endoscopy in the diagnosis of Crohn’s disease
Niv, Yaron
2013-01-01
Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score) for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn’s disease. PMID:23818810
Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.
Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A
2008-07-01
Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.
AGR-5/6/7 Irradiation Test Predictions using PARFUME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skerjanc, William F.
PARFUME, (PARticle FUel ModEl) a fuel performance modeling code used for high temperature gas-cooled reactors (HTGRs), was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using predicted physics and thermal hydraulics data. The AGR-5/6/7 test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter north east flux trap (NEFT) position of Advanced Test Reactor (ATR). Each capsule contains compacts filled with uranium oxycarbide (UCO) unaltered fuel particles. This report documents themore » calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated source term from the driver fuel. The calculations include modeling of the AGR-5/6/7 irradiation that is scheduled to occur from October 2017 to April 2021 over a total of 13 ATR cycles, including nine normal cycles and four Power Axial Locator Mechanism (PALM) cycle for a total between 500 – 550 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 2, and 4. Fuel particle failures were predicted in Capsule 3 due to internal particle pressure. These failures were predicted in the highest temperature compacts. Capsule 5 fuel particle failures were due to inner pyrolytic carbon (IPyC) cracking causing localized stresses concentrations in the SiC layer. This capsule predicted the highest particle failures due to the lower irradiation temperature. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. The two capsules at the two ends of the test train, Capsules 1 and 5 experienced the smallest buffer-IPyC gap formation due to the lower irradiation fluences and temperatures. Capsule 3 experienced the largest buffer-IPyC gap formation of just under 24 µm. The release fraction of fission products Ag, Cs, and Sr silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 84.8% for the TRISO fuel particles. The release fraction of the other two fission products, Cs and Sr are much smaller and, in most cases, less than 1%. The notable exception is again in Capsule 3, where the release fraction for Cs and Sr reach up to 9.7% and 19.1%, respectively.« less
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Davison, James A
2015-01-01
To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer.
Vu, Thiennu H.; Alemayehu, Yemisrach; Werb, Zena
2009-01-01
The study of distal lung morphogenesis and vascular development would be greatly facilitated by an in vitro or ex vivo experimental model. In this study we show that the growth of mouse embryonic day 12.5 lung rudiments implanted underneath the kidney capsules of syngeneic or immunodeficient hosts follows closely lung development in utero. The epithelium develops extensively with both proximal and distal differentiation to the saccular stage. The vasculature also develops extensively. Large blood vessels accompany large airways and capillaries develop within the saccular walls. Interestingly, vessels in the lung grafts develop from endothelial progenitor cells endogenous to the explants and host vessels do not vascularize the grafts independently. This suggests that embryonic lungs possess mechanisms to prevent the inappropriate ingrowth of surrounding vessels. However, vessels in the lung grafts do connect to host vessels, showing that embryonic lungs have the ability to stimulate host angiogenesis and recruit host vessel connections. These data support the hypothesis that the lung vasculature develops by both vasculogenic and angiogenic processes: a vascular network develops in situ in lung mesenchyme, which is then connected to angiogenic processes from central vessels. The lung renal capsule allograft is thus an excellent model to study the development of the pulmonary vasculature and of late fetal lung development that requires a functional blood supply. PMID:12591600
Scaling of Liquid DT Layer Capsules to an ICF Burning Plasma
NASA Astrophysics Data System (ADS)
Olson, R. E.; Peterson, R. R.; Haines, B. M.; Yi, S. A.; Bradley, P. A.; Zylstra, A. B.; Kline, J. L.; Leeper, R. J.; Batha, S. H.
2017-10-01
Recent experiments at the NIF demonstrated cryogenic liquid DT layer ICF implosions. Unlike DT ice layer implosions, DT liquid layer designs can operate with low-to-moderate convergence ratio (12
Rugby-like hohlraum experimental designs for demonstrating x-ray drive enhancement
NASA Astrophysics Data System (ADS)
Amendt, Peter; Cerjan, C.; Hinkel, D. E.; Milovich, J. L.; Park, H.-S.; Robey, H. F.
2008-01-01
A suite of experimental designs for the Omega laser facility [Boehly et al., Opt. Commun. 133, 495 (1997)] using rugby and cylindrical hohlraums is proposed to confirm the energetics benefits of rugby-shaped hohlraums over cylinders under optimal implosion symmetry conditions. Postprocessed Dante x-ray drive measurements predict a 12-17eV (23%-36%) peak hohlraum temperature (x-ray flux) enhancement for a 1ns flattop laser drive history. Simulated core self-emission x-ray histories also show earlier implosion times by 200-400ps, depending on the hohlraum case-to-capsule ratio and laser-entrance-hole size. Capsules filled with 10 or 50atm of deuterium (DD) are predicted to give in excess of 1010 neutrons in two-dimensional hohlraum simulations in the absence of mix, enabling DD burn history measurements for the first time in indirect-drive on Omega. Capsule designs with 50atm of DHe3 are also proposed to make use of proton slowing for independently verifying the drive benefits of rugby hohlraums. Scale-5/4 hohlraum designs are also introduced to provide further margin to potential laser-plasma-induced backscatter and hot-electron production.
Residual mercury content and leaching of mercury and silver from used amalgam capsules.
Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R
2002-06-01
The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.
Near Space Lab-Rat Experimentation using Stratospheric Balloon
NASA Astrophysics Data System (ADS)
Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter
2016-07-01
First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.
Miglino, M A; Franciolli, A L R; de Oliveira, M F; Ambrósio, C E; Bonatelli, M; Machado, M R F; Mess, A
2008-08-01
Guinea pig related rodents possess numerous derived placental characters. We attempt to identify diversity within the visceral yolk sac and its association with the chorioallantoic placenta in three species of caviids, two of them possessing a capsule formed by the decidua that covers the chorioallantoic placenta. The results verify that in early pregnancy all three species have an inverted yolk sac placenta. In advanced pregnancy the species differ: Galea spixii, as representative without a capsule, bear a yolk sac in apposition to the chorioallantoic placenta with signs of exchange activity until term. Galea is similar to other caviomorphs in this respect. In Dasyprocta leporina and Cuniculus paca, the representatives possessing a capsule, the yolk sac endoderm lacks signs of substance exchange. Evidently, the presence of a capsule prevents such an interaction. The variations established here must be considered if animal models for human placentation are required which have restricted access to the chorioallantoic placenta from the outside.
NASA Astrophysics Data System (ADS)
Murphy, T. J.; Kyrala, G. A.; Krasheninnikova, N. S.; Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Obrey, K. A. D.; Baumgaertel, J. A.; Hsu, S. C.; Shah, R. C.; Hakel, P.; Kline, J. L.; Schmitt, M. J.; Kanzleiter, R. J.; Batha, S. H.; Wallace, R. J.; Bhandarkar, S.; Fitzsimmons, P.; Hoppe, M.; Nikroo, A.; McKenty, P.
2016-03-01
Capsules driven with polar drive [1, 2] on the National Ignition Facility [3] are being used [4] to study mix in convergent geometry. In preparation for experiments that will utilize deuterated plastic shells with a pure tritium fill, hydrogen-filled capsules with copper- doped deuterated layers have been imploded on NIF to provide spectroscopic and nuclear measurements of capsule performance. Experiments have shown that the mix region, when composed of shell material doped with about 1% copper (by atom), reaches temperatures of about 2 keV, while undoped mixed regions reach about 3 keV. Based on the yield from these implosions, we estimate the thickness of CD that mixed into the gas as between about 0.25 and 0.43 μm of the inner capsule surface, corresponding to about 5 to 9 μg of material. Using 5 atm of tritium as the fill gas should result in over 1013 DT neutrons being produced, which is sufficient for neutron imaging [5].
Magnetic localization and orientation of the capsule endoscope based on a random complex algorithm.
He, Xiaoqi; Zheng, Zizhao; Hu, Chao
2015-01-01
The development of the capsule endoscope has made possible the examination of the whole gastrointestinal tract without much pain. However, there are still some important problems to be solved, among which, one important problem is the localization of the capsule. Currently, magnetic positioning technology is a suitable method for capsule localization, and this depends on a reliable system and algorithm. In this paper, based on the magnetic dipole model as well as magnetic sensor array, we propose nonlinear optimization algorithms using a random complex algorithm, applied to the optimization calculation for the nonlinear function of the dipole, to determine the three-dimensional position parameters and two-dimensional direction parameters. The stability and the antinoise ability of the algorithm is compared with the Levenberg-Marquart algorithm. The simulation and experiment results show that in terms of the error level of the initial guess of magnet location, the random complex algorithm is more accurate, more stable, and has a higher "denoise" capacity, with a larger range for initial guess values.
NO PLIF Visualizations of the Orion Capsule in LENS-I
NASA Technical Reports Server (NTRS)
Combs, C.; Clemens, N.; Danehy, P. M.; Bathel, B.; Parker, R.; Wadhams, T.; Holden, M.; Kirk, B.
2013-01-01
Planar laser-induced fluorescence (PLIF) of nitric oxide (NO) was used to visualize the interaction of reaction-control-system (RCS) jet flows in the wake of a hypersonic capsule reentry vehicle. The tests were performed at the Calspan University at Buffalo Research Center's (CUBRC) LENS-I reflected shock tunnel facility. This was the first application of PLIF to study RCS jets in a large-scale pulsed hypersonic facility. The LENS-I facility allowed RCS jet flows to be studied while varying the flow enthalpy, Reynolds number, angle of attack and jet configuration. The interaction of pitch and roll jets with the flowfield was investigated. Additionally, thin film sensors were used to monitor heat transfer on the surface of the model to detect any localized heating resulting from the firing of the RCS jets. Tests were conducted with the model held at angles of attack of 18deg and 22deg. The nominal Mach number in all tests was 8, while Reynolds number based on model diameter ranged from 2.2x10(exp 6) - 1.5x10(exp 7). Images were processed using the Virtual Diagnostics Interface (ViDI) system developed at NASA Langley Research Center to provide a three-dimensional display of the experimental data.
Kronschläger, Martin; Stimpfl, Thomas; Ruiß, Manuel; Hirnschall, Nino; Leisser, Christoph; Findl, Oliver
2018-04-01
To determine the pharmacokinetics of perorally administered caffeine, a widely consumed and potent dietary antioxidant, in the anterior lens capsule and lens epithelial cells, a crucial cell monolayer for cataract development. Bilateral cataract patients were scheduled for cataract surgery with a caffeine abstinence of 1 week before surgery of each eye. At the day of surgery of the second eye patients were administered no drink (0-mg group) or coffee with 60-, 120-, or 180-mg caffeine. After capsulorhexis the lens capsule including lens epithelial cells was transferred to a test tube for analysis of caffeine concentration by gas chromatography-mass spectrometry (GC-MS/MS). Coffee consumption significantly (P < 0.05) increased caffeine levels of the lens capsule/epithelium in the 60-, 120-, and 180-mg group. Caffeine concentrations (caffeine ng/lens capsule/epithelium) measured as difference between 1st and 2nd eye were -0.52 ± 1.16 (0-mg group, n = 7), 1.88 ± 2.02 (60-mg group, n = 8), 2.09 ± 0.67 (120-mg group, n = 9), and 3.68 ± 1.86 (180-mg group, n = 9). The increase constant of caffeine in a linear regression model was estimated as a 95% CI 0.02 ± 0.0046 (degrees of freedom; 25; r = 0.85). Peroral intake of coffee significantly increased caffeine concentrations in the lens capsule and lens epithelial cells in a dose-dependent manner. This information is important for further investigations on preventing cataract.
Macchi, Elena; Zema, Lucia; Pandey, Preetanshu; Gazzaniga, Andrea; Felton, Linda A
2016-03-01
In a previous study, hydroxypropyl cellulose (HPC)-based capsular shells prepared by injection molding and intended for pulsatile release were successfully coated with 10mg/cm(2) Eudragit® L film. The suitability of HPC capsules for the development of a colon delivery platform based on a time dependent approach was demonstrated. In the present work, data logging devices (PyroButton®) were used to monitor the microenvironmental conditions, i.e. temperature (T) and relative humidity (RH), during coating processes performed under different spray rates (1.2, 2.5 and 5.5g/min). As HPC-based capsules present special features, a preliminary study was conducted on commercially available gelatin capsules for comparison purposes. By means of PyroButton data-loggers it was possible to acquire information about the impact of the effective T and RH conditions experienced by HPC substrates during the process on the technological properties and release performance of the coated systems. The use of increasing spray rates seemed to promote a tendency of the HPC shells to slightly swell at the beginning of the spraying process; moreover, capsules coated under spray rates of 1.2 and 2.5g/min showed the desired release performance, i.e. ability to withstand the acidic media followed by the pulsatile release expected for uncoated capsules. Preliminary stability studies seemed to show that coating conditions might also influence the release performance of the system upon storage. Copyright © 2015 Elsevier B.V. All rights reserved.
Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads.
Sliker, Levin J; Kern, Madalyn D; Schoen, Jonathan A; Rentschler, Mark E
2012-10-01
The state-of-the-art technology for gastrointestinal (GI) tract exploration is a capsule endoscope (CE). Capsule endoscopes are pill-sized devices that provide visual feedback of the GI tract as they move passively through the patient. These passive devices could benefit from a mobility system enabling maneuverability and controllability. Potential benefits of a tethered robotic capsule endoscope (tRCE) include faster travel speeds, reaction force generation for biopsy, and decreased capsule retention. In this work, a tethered CE is developed with an active locomotion system for mobility within a collapsed lumen. Micro-patterned polydimethylsiloxane (PDMS) treads are implemented onto a custom capsule housing as a mobility method. The tRCE housing contains a direct current (DC) motor and gear train to drive the treads, a video camera for visual feedback, and two light sources (infrared and visible) for illumination. The device was placed within the insufflated abdomen of a live anesthetized pig to evaluate mobility performance on a planar tissue surface, as well as within the cecum to evaluate mobility performance in a collapsed lumen. The tRCE was capable of forward and reverse mobility for both planar and collapsed lumen tissue environments. Also, using an onboard visual system, the tRCE was capable of demonstrating visual feedback within an insufflated, anesthetized porcine abdomen. Proof-of-concept in vivo tRCE mobility using micro-patterned PDMS treads was shown. This suggests that a similar method could be implemented in future smaller, faster, and untethered RCEs.
Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis
Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.
2014-01-01
The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712
Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.
Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio
2011-08-02
Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.
Small bowel endoluminal imaging (capsule and enteroscopy)
Murino, Alberto
2017-01-01
Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice. PMID:28839900
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers
NASA Astrophysics Data System (ADS)
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-10-01
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5-100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed.
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers.
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-10-03
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5-100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed.
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-01-01
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5–100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed. PMID:27694922
Oxygen Fugacity in Large Metal Capsules
NASA Astrophysics Data System (ADS)
Faul, U.; Cline, C. J., II; Jackson, I.; Berry, A.
2016-12-01
During experiments with iron bearing silicates, equilibration between metal capsules and sample interior depends on diffusion of Fe if the capsule composition is not initially in equilibrium with the sample composition. For example, placing Pt or Ni capsules in contact with Fe-bearing olivine leads to Fe-loss from the olivine. In a fully equilibrated system the Fe contents of coexisting metal capsule and olivine reflect the oxygen fugacity (fO2) of the system. Experiments were conducted with olivine encapsulated or wrapped in four different metals (Fe, Ni70Fe30, Ni and Pt) to determine the fO2 in the cm-sized samples used for deformation and seismic property experiments. Small Pt particles mixed with olivine powder were used as fO2 sensors in the interior of the capsules. The results show an ordering of the fO2 in the interior that is consistent with the enclosing metals, i.e. the fO2 is lowest in a Fe capsule and highest in a Pt capsule. However, fO2 values in the more oxidizing metal capsules are substantially below their respective metal-oxide buffers. For example, solgel olivine encapsulated in Ni has an oxygen fugacity that is more than three orders of magnitude below Ni-NiO at 1200C and 0.3 GPa. The fO2 in a capsule interior is therefore to some extent self-buffering and only moderately influenced by the composition of the capsule. While the Pt particles in the interior are equilibrated, Fe gradients from the interior up to the Pt and Ni sample-capsule interfaces show that Fe loss into the capsules is diffusion limited. The fO2 at the interface also has implications for the water retention in unbuffered capsules. We infer that relatively high fO2 and hence fH2O observed adjacent to Pt capsules enables retention of water in these capsules, but the fO2 adjacent to Ni capsules is too low and water is lost.
2012-07-02
CAPE CANAVERAL, Fla. – Dan Dumbacher, NASA deputy associate administrator for Exploration Systems Development, addresses the audience assembled in Kennedy Space Center's Operations and Checkout Building high bay for an event marking the arrival of NASA's first space-bound Orion capsule in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
Neutron-induced reactions in the hohlraum to study reaction in flight neutrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boswell, M. S.; Elliott, S. R.; Tybo, J.
2013-04-19
We are currently developing the physics necessary to measure the Reaction In Flight (RIF) neutron flux from a NIF capsule. A measurement of the RIF neutron flux from a NIF capsule could be used to deduce the stopping power in the cold fuel of the NIF capsule. A foil irradiated at the Omega laser at LLE was counted at the LANL low-background counting facility at WIPP. The estimated production rate of {sup 195}Au was just below our experimental sensitivity. We have made several improvements to our counting facility in recent months. These improvements are designed to increase our sensitivity, andmore » include installing two new low-background detectors, and taking steps to reduce noise in the signals.« less
21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...
Small intestinal model for electrically propelled capsule endoscopy
2011-01-01
The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218
Advanced Image Enhancement Method for Distant Vessels and Structures in Capsule Endoscopy
Pedersen, Marius
2017-01-01
This paper proposes an advanced method for contrast enhancement of capsule endoscopic images, with the main objective to obtain sufficient information about the vessels and structures in more distant (or darker) parts of capsule endoscopic images. The proposed method (PM) combines two algorithms for the enhancement of darker and brighter areas of capsule endoscopic images, respectively. The half-unit weighted-bilinear algorithm (HWB) proposed in our previous work is used to enhance darker areas according to the darker map content of its HSV's component V. Enhancement of brighter areas is achieved thanks to the novel threshold weighted-bilinear algorithm (TWB) developed to avoid overexposure and enlargement of specular highlight spots while preserving the hue, in such areas. The TWB performs enhancement operations following a gradual increment of the brightness of the brighter map content of its HSV's component V. In other words, the TWB decreases its averaged weights as the intensity content of the component V increases. Extensive experimental demonstrations were conducted, and, based on evaluation of the reference and PM enhanced images, a gastroenterologist (Ø.H.) concluded that the PM enhanced images were the best ones based on the information about the vessels, contrast in the images, and the view or visibility of the structures in more distant parts of the capsule endoscopy images. PMID:29225668
Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Zhihua
2012-11-01
This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.
Eldred, Julie A.; McDonald, Matthew; Wilkes, Helen S.; Spalton, David J.; Wormstone, I. Michael
2016-01-01
Secondary visual loss occurs in millions of patients due to a wound-healing response, known as posterior capsule opacification (PCO), following cataract surgery. An intraocular lens (IOL) is implanted into residual lens tissue, known as the capsular bag, following cataract removal. Standard IOLs allow the anterior and posterior capsules to become physically connected. This places pressure on the IOL and improves contact with the underlying posterior capsule. New open bag IOL designs separate the anterior capsule and posterior capsules and further reduce PCO incidence. It is hypothesised that this results from reduced cytokine availability due to greater irrigation of the bag. We therefore explored the role of growth factor restriction on PCO using human lens cell and tissue culture models. We demonstrate that cytokine dilution, by increasing medium volume, significantly reduced cell coverage in both closed and open capsular bag models. This coincided with reduced cell density and myofibroblast formation. A screen of 27 cytokines identified nine candidates whose expression profile correlated with growth. In particular, VEGF was found to regulate cell survival, growth and myofibroblast formation. VEGF provides a therapeutic target to further manage PCO development and will yield best results when used in conjunction with open bag IOL designs. PMID:27076230
Effects of alga polysaccharide capsule shells on in-vivo bioavailability and disintegration
NASA Astrophysics Data System (ADS)
Li, Ting; Guo, Shuju; Ma, Lin; Yuan, Yi; Han, Lijun
2012-01-01
Gelatin has been used in hard capsule shells for more than a century, and some shortcomings have appeared, such as high moisture content and risk of transmitting diseases of animal origin to people. Based on available studies regarding gelatin and vegetable shells, we developed a new type of algal polysaccharide capsule (APPC) shells. To test whether our products can replace commercial gelatin shells, we measured in-vivo plasma concentration of 12 selected volunteers with a model drug, ibuprofen, using high performance liquid chromatography (HPLC), by calculating the relative bioavailability of APPC and Qualicaps® referenced to gelatin capsules and assessing bioequivalence of the three types of shells, and calculated pharmacokinetic parameters with the software DAS 2.0 (China). The results show that APPC shells possess bioequivalence with Qualicaps® and gelatin shells. Moreover, the disintegration behavior of four types of shells (APPC, Vegcaps®, Qualicaps® and gelatin shells) with the content of lactose and radioactive element (99mTc) was observed via gamma-scintigraphic images. The bioavailability and gamma-scintigraphic studies showed that APPC was not statistically different from other vegetable and gelatin capsule shells with respect to in-vivo behavior. Hence, it can be concluded that APPCs are exchangeable with other vegetable and gelatin shells.
Thyme Oil Encapsulated in Halloysite Nanotubes for Antimicrobial Packaging System.
Lee, Min Hyeock; Seo, Hyun-Sun; Park, Hyun Jin
2017-04-01
An antimicrobial capsule releasing thyme oil was developed using modified halloysite nanotubes (HNTs). In order to increase the pore volume, HNTs were treated with 5.0 mol/L NaOH solution, which resulted in the encapsulation of more thyme oil molecules inside the HNTs. The morphology of the raw HNTs and NaOH-treated HNTs (N-HNTs) was characterized using transmission electron microscopy and nitrogen adsorption-desorption analysis. The loading capacity increased from 180.7 ± 12.7 to 256.4 ± 16.7 mg thyme oil/g HNT after the NaOH treatment. The aerial release characteristics of thyme oil from both the HNT capsules were investigated in a closed-package atmosphere system at 4, 25, and 40 °C. The antimicrobial activity of the capsule against Escherichia coli O157:H7 was determined using the vapor phase assay. Moreover, the antimicrobial effects of the capsule against E. coli O157:H7, total mesophilic aerobic bacteria (MAB), and molds and yeasts (MY) on the surfaces of cherry tomatoes were investigated at 4 and 25 °C for 5 d. When the cherry tomatoes were exposed to the thyme oil-loaded N-HNT capsule, the number of E. coli O157:H7, MAB, and MY significantly reduced during storage. © 2017 Institute of Food Technologists®.
NASA Astrophysics Data System (ADS)
Baumgarten, Lorenz; Kierfeld, Jan
2018-05-01
We study the influence of thermal fluctuations on the buckling behavior of thin elastic capsules with spherical rest shape. Above a critical uniform pressure, an elastic capsule becomes mechanically unstable and spontaneously buckles into a shape with an axisymmetric dimple. Thermal fluctuations affect the buckling instability by two mechanisms. On the one hand, thermal fluctuations can renormalize the capsule's elastic properties and its pressure because of anharmonic couplings between normal displacement modes of different wavelengths. This effectively lowers its critical buckling pressure [Košmrlj and Nelson, Phys. Rev. X 7, 011002 (2017), 10.1103/PhysRevX.7.011002]. On the other hand, buckled shapes are energetically favorable already at pressures below the classical buckling pressure. At these pressures, however, buckling requires to overcome an energy barrier, which only vanishes at the critical buckling pressure. In the presence of thermal fluctuations, the capsule can spontaneously overcome an energy barrier of the order of the thermal energy by thermal activation already at pressures below the critical buckling pressure. We revisit parameter renormalization by thermal fluctuations and formulate a buckling criterion based on scale-dependent renormalized parameters to obtain a temperature-dependent critical buckling pressure. Then we quantify the pressure-dependent energy barrier for buckling below the critical buckling pressure using numerical energy minimization and analytical arguments. This allows us to obtain the temperature-dependent critical pressure for buckling by thermal activation over this energy barrier. Remarkably, both parameter renormalization and thermal activation lead to the same parameter dependence of the critical buckling pressure on temperature, capsule radius and thickness, and Young's modulus. Finally, we study the combined effect of parameter renormalization and thermal activation by using renormalized parameters for the energy barrier in thermal activation to obtain our final result for the temperature-dependent critical pressure, which is significantly below the results if only parameter renormalization or only thermal activation is considered.
Aling, Joanna; Podczeck, Fridrun
2012-11-20
The aim of this work was to investigate the plug formation and filling properties of powdered herbal leaves using hydrogenated cotton seed oil as an alternative lubricant. In a first step, unlubricated and lubricated herbal powders were studied on a small scale using a plug simulator, and low-force compression physics and parameterization techniques were used to narrow down the range in which the optimum amount of lubricant required would be found. In a second step these results were complemented with investigations into the flow properties of the powders based on packing (tapping) experiments to establish the final optimum lubricant concentration. Finally, capsule filling of the optimum formulations was undertaken using an instrumented tamp filling machine. This work has shown that hydrogenated cotton seed oil can be used advantageously for the lubrication of herbal leaf powders. Stickiness as observed with magnesium stearate did not occur, and the optimum lubricant concentration was found to be less than that required for magnesium stearate. In this work, lubricant concentrations of 1% or less hydrogenated cotton seed oil were required to fill herbal powders into capsules on the instrumented tamp-filling machine. It was found that in principle all powders could be filled successfully, but that for some powders the use of higher compression settings was disadvantageous. Relationships between the particle size distributions of the powders, their flow and consolidation as well as their filling properties could be identified by multivariate statistical analysis. The work has demonstrated that a combination of the identification of plug formation and powder flow properties is helpful in establishing the optimum lubricant concentration required using a small quantity of powder and a powder plug simulator. On an automated tamp-filling machine, these optimum formulations produced satisfactory capsules in terms of coefficient of fill weight variability and capsule weight. Copyright © 2012 Elsevier B.V. All rights reserved.
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
Development of an Implantable WBAN Path-Loss Model for Capsule Endoscopy
NASA Astrophysics Data System (ADS)
Aoyagi, Takahiro; Takizawa, Kenichi; Kobayashi, Takehiko; Takada, Jun-Ichi; Hamaguchi, Kiyoshi; Kohno, Ryuji
An implantable WBAN path-loss model for a capsule endoscopy which is used for examining digestive organs, is developed by conducting simulations and experiments. First, we performed FDTD simulations on implant WBAN propagation by using a numerical human model. Second, we performed FDTD simulations on a vessel that represents the human body. Third, we performed experiments using a vessel of the same dimensions as that used in the simulations. On the basis of the results of these simulations and experiments, we proposed the gradient and intercept parameters of the simple path-loss in-body propagation model.
Okuno, Yuji; Iwamoto, Wataru; Matsumura, Noboru; Oguro, Sota; Yasumoto, Taku; Kaneko, Takao; Ikegami, Hiroyasu
2017-02-01
To evaluate clinical outcomes of transcatheter arterial embolization (TAE) for adhesive capsulitis resistant to conservative treatments. This study comprised 25 patients (18 women and 7 men; mean age, 53.8 y; range, 39-68 y) with adhesive capsulitis resistant to conservative treatments. TAE was performed, and adverse events (AEs), pain visual analog scale (VAS) score changes, range of motion (ROM), and American Shoulder and Elbow Surgeons (ASES) scores were assessed. Abnormal vessels were identified in all patients. No major AEs were associated with TAE. One patient was lost to follow-up. The remaining 24 patients were available for final follow-up (mean, 36.1 months; range, 30-44 months). Of the 24 patients, 16 (67%) experienced quick improvement of nighttime pain (ie, VAS scores decreased > 50% from baseline) within 1 week, and 21 (87%) improved within 1 month. In terms of mean overall pain (ie, pain at its worst), VAS scores significantly decreased at 1, 3, and 6 months after treatment (82 mm before treatment vs 52, 19, and 8 mm after treatment; P < .001). ASES scores significantly improved at 1, 3, and 6 months after treatment (16.1 before treatment vs 41.4, 69.1, and 83.5 after treatment; P < .001). No symptom recurrence or late-onset AEs were observed. Shoulder ROM and function further improved during midterm follow-up. TAE is a possible treatment option for patients with adhesive capsulitis that has failed to improve with conservative treatments. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Kim, Kyung-Hee; Suh, Jung-Woo; Oh, Ki Young
2017-08-03
Local administration of opioids causes effective analgesia without adverse effects related to the central nervous system. After the beneficial demonstration of peripheral opioid receptors in joint synovia, intra-articular opioid injections were used for pain treatment. Clinical studies have reported the safety and efficacy of hyaluronate injection in the shoulder joint of patients with osteoarthritis, periarthritis, rotator cuff tears, and adhesive capsulitis. To estimate the efficacy of intra-articular hyaluronate and tramadol injection for adhesive capsulitis of the shoulder compared with that of intra-articular hyaluronate injection alone. Thirty patients with adhesive capsulitis of the shoulder were randomized to the hyaluronate group (n= 16) or the tramadol group (n= 14). Hyaluronate group members were administered five weekly intra-articular hyaluronate injections; tramadol group members were administered three weekly intra-articular hyaluronate and tramadol injections and then two weekly intra-articular injections of hyaluronate. Visual Analog Scale (VAS), passive range of motion (PROM) of the shoulder joint, and Shoulder Pain and Disability Index (SPADI) scores were assessed at baseline and weeks 1, 2, 3, 4, and 6 after the initial injection. A significant improvement was observed in VAS, PROM, and SPADI scores between time points in both groups. In comparison in both groups at weeks 1 and 2 after the initial injection the VAS scores of the tramadol group were significantly lower than those of the hyaluronate group. Intra-articular hyaluronate with tramadol showed more rapid and strong analgesic effects than intra-articular hyaluronate alone and did not induce any adverse effects.
The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules
NASA Astrophysics Data System (ADS)
Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko
2016-03-01
The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.
Johnstone, Nancy; Ward, Daniel A
2005-01-01
The objective of this retrospective study was to report the incidence of posterior capsule disruption during routine phacoemulsification and to document the postoperative outcomes and complications in eyes with posterior capsule disruption compared with eyes with intact posterior capsules. Records of 143 dogs (244 eyes) were reviewed. Data collected included whether the posterior capsule was disrupted, whether the disruption was planned or accidental, whether an intraocular lens was implanted, and visual outcome. Records were reviewed for postoperative complications. Intraocular lens implantation rates, complication rates, and visual outcomes were compared between intact and disrupted posterior capsule groups using Chi-square analyses. The posterior capsule was disrupted in 33/244 eyes (14%). Planned capsulotomies accounted for 36% of the disruptions. Intraocular lenses were implanted in 76% of eyes without a disruption of the posterior capsule and in 31% of eyes with a posterior capsule disruption. Intraocular lenses were more likely to be implanted in eyes with a planned disruption of the posterior capsule (7/12; 58%) than in eyes with an accidental disruption (3/20; 15%). There were no significant differences in postoperative complications or visual outcome between eyes with posterior capsule disruption and those without. The most significant complication of posterior capsule disruption during phacoemulsification is the inability to implant an intraocular lens. Intraocular lenses are more likely to be placed in eyes with intentional disruptions of the posterior capsule than those with accidental ruptures.
Posnien, Nico; Bucher, Gregor
2010-02-01
The insect head is composed of several segments. During embryonic development, the segments fuse to form a rigid head capsule where obvious segmental boundaries are lacking. Hence, the assignment of regions of the insect head to specific segments is hampered, especially with respect to dorsal (vertex) and lateral (gena) parts. We show that upon Tribolium labial (Tc-lab) knock down, the intercalary segment is deleted but not transformed. Furthermore, we find that the intercalary segment contributes to lateral parts of the head cuticle in Tribolium. Based on several additional mutant and RNAi phenotypes that interfere with gnathal segment development, we show that these segments do not contribute to the dorsal head capsule apart from the dorsal ridge. Opposing the classical view but in line with findings in the vinegar fly Drosophila melanogaster and the milkweed bug Oncopeltus fasciatus, we propose a "bend and zipper" model for insect head capsule formation.
Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy
Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young
2011-01-01
Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841
Analysis of NIF experiments with the minimal energy implosion model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, B., E-mail: bcheng@lanl.gov; Kwan, T. J. T.; Wang, Y. M.
2015-08-15
We apply a recently developed analytical model of implosion and thermonuclear burn to fusion capsule experiments performed at the National Ignition Facility that used low-foot and high-foot laser pulse formats. Our theoretical predictions are consistent with the experimental data. Our studies, together with neutron image analysis, reveal that the adiabats of the cold fuel in both low-foot and high-foot experiments are similar. That is, the cold deuterium-tritium shells in those experiments are all in a high adiabat state at the time of peak implosion velocity. The major difference between low-foot and high-foot capsule experiments is the growth of the shock-inducedmore » instabilities developed at the material interfaces which lead to fuel mixing with ablator material. Furthermore, we have compared the NIF capsules performance with the ignition criteria and analyzed the alpha particle heating in the NIF experiments. Our analysis shows that alpha heating was appreciable only in the high-foot experiments.« less
Nifedipine capsules may provide a viable alternative to oral powders for paediatric patients.
Helin-Tanninen, M; Naaranlahti, T; Kontra, K; Savolainen, K
2007-02-01
To compare content uniformities between different sizes of extemporaneously compounded nifedipine oral powders and capsules, in order to find out if capsules could be used instead of oral powders as paediatric medications. Actual content and content uniformity of extemporaneously compounded 1-mg nifedipine oral powders and capsules were evaluated by a high performance liquid chromatographic assay. Capsules and powders were prepared by triturating 10-mg nifedipine tablets with different amounts of lactose or microcrystalline cellulose with a mortar and pestle using a standard geometric dilution technique. Oral powders were weighed individually and capsules were filled by a hand-operated capsule-filling machine. Four different sizes of powders (500, 300, 100 and 50 mg) and three different sizes of capsules (numbers 1, 3 and 4) were prepared. Ten oral powders and 10 capsules from each batch were randomly selected and individually assayed for nifedipine amount. The extemporaneously prepared nifedipine oral powders and capsules were within acceptable limits for content uniformity, as defined by the European Pharmacopoeia, but the results indicate that the loss of nifedipine during the preparation process may be considerable for both preparations. The concentration on nifedipine decreased while the total mass of the oral powder decreased. These results demonstrate that nifedipine oral powders can be replaced by capsules, whose contents are emptied for use, in paediatric medications. Compounding small capsules, such as size number 3 or 4, is acceptable when considering the average drug content. The total weight of the oral powder should be at least 300 mg. The preparation of nifedipine in all studied capsule sizes was safe with either lactose monohydrate or microcrystalline cellulose as excipients. Thus, emptied capsules seem to be a good choice for delivering a paediatric medication. The loss of nifedipine was considerable in oral powders with low total weight.
Internalization of Red Blood Cell-Mimicking Hydrogel Capsules with pH-Triggered Shape Responses
2015-01-01
We report on naturally inspired hydrogel capsules with pH-induced transitions from discoids to oblate ellipsoids and their interactions with cells. We integrate characteristics of erythrocytes such as discoidal shape, hollow structure, and elasticity with reversible pH-responsiveness of poly(methacrylic acid) (PMAA) to design a new type of drug delivery carrier to be potentially triggered by chemical stimuli in the tumor lesion. The capsules are fabricated from cross-linked PMAA multilayers using sacrificial discoid silicon templates. The degree of capsule shape transition is controlled by the pH-tuned volume change, which in turn is regulated by the capsule wall composition. The (PMAA)15 capsules undergo a dramatic 24-fold volume change, while a moderate 2.3-fold volume variation is observed for more rigid PMAA–(poly(N-vinylpyrrolidone) (PMAA–PVPON)5 capsules when solution pH is varied between 7.4 and 4. Despite that both types of capsules exhibit discoid-to-oblate ellipsoid transitions, a 3-fold greater swelling in radial dimensions is found for one-component systems due to a greater degree of the circular face bulging. We also show that (PMAA–PVPON)5 discoidal capsules interact differently with J774A.1 macrophages, HMVEC endothelial cells, and 4T1 breast cancer cells. The discoidal capsules show 60% lower internalization as compared to spherical capsules. Finally, hydrogel capsules demonstrate a 2-fold decrease in size upon internalization. These capsules represent a unique example of elastic hydrogel discoids capable of pH-induced drastic and reversible variations in aspect ratios. Considering the RBC-mimicking shape, their dimensions, and their capability to undergo pH-triggered intracellular responses, the hydrogel capsules demonstrate considerable potential as novel carriers in shape-regulated transport and cellular uptake. PMID:24848786
Nikzad, Jafar; Shahhosseini, Soraya; Tabarzad, Maryam; Nafissi-Varcheh, Nastaran; Torshabi, Maryam
2017-02-14
In the pharmaceutical industry, hard- and soft-shelled capsules are typically made from gelatin, commonly derived from bovine and porcine sources. To ensure that pharmaceutical products comply with halal regulations in Muslim countries (no porcine products allowed), development of a valid, reliable, quick, and most importantly, cost-effective tests are of utmost importance. We developed a species-specific duplex polymerase chain reaction (PCR) assay targeting 149 bp porcine and 271 bp bovine mitochondrial DNA (mtDNA) to simultaneously detect both porcine and bovine DNA (in one reaction at the same time) in gelatin. Some additional simplex PCR tests (targeting 126 bp bovine and 212 bp porcine mtDNA) and real-time PCR using a commercially available kit (for identification of porcine DNA) were used to verify the selectivity and sensitivity of our duplex PCR. After optimization of DNA extraction and PCR methods, hard/soft pharmaceutical gelatin capsules (containing drug) were tested for the presence of porcine and/or bovine DNA. Duplex PCR detected the presence of as little as 0.1% porcine DNA, which was more accurate than the commercially available kit. Of all gelatin capsules tested (n = 24), 50% contained porcine DNA (pure porcine gelatin alone or in combination with bovine gelatin). Duplex PCR presents an easy-to-follow, quick, low-cost and reliable method to simultaneously detect porcine and bovine DNAs (>100 bp) in minute amounts in highly processed gelatin-containing pharmaceutical products (with a 0.1% sensitivity for porcine DNA) which may be used for halal authentication. Simultaneous detection of porcine and bovine DNA in gelatin capsules by duplex PCR.
NASA Technical Reports Server (NTRS)
Norgard, John D.
2012-01-01
For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30? angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit, and far-field hybrid antenna measurements at 3m are being extrapolated inward to the 1m distance for similar comparisons.
Clark, Annie M; Pellock, John M; Holmay, Mary; Anders, Bob; Cloyd, James
2016-04-01
The objectives of these two studies were to determine if beads from extended-release topiramate capsules sprinkled onto soft food are bioequivalent to the intact capsule and if beads from the capsule can be passed through enteral gastrostomy (G-) and jejunostomy (J-) feeding tubes. Bioequivalence of 200-mg USL255 (Qudexy XR [topiramate] extended-release capsules) sprinkled onto soft food (applesauce) versus the intact capsule was evaluated in a phase 1, randomized, single-dose, crossover study (N=36). Pharmacokinetic evaluations included area under the curve (AUC), maximum plasma concentration (Cmax), time to Cmax (Tmax), and terminal elimination half-life (t1/2). If 90% confidence intervals (CI) of the ratio of geometric least-squares means were between 0.80 and 1.25, AUC and Cmax were considered bioequivalent. In separate in vitro experiments, 100-mg USL255 beads were passed through feeding tubes using gentle syringe pressure to develop a clog-free bead-delivery method. Multiple tube sizes (14- to 18-French [Fr] tubes), dilutions (5 mg/15 mL-25 mg/15 mL), and diluents (deionized water, apple juice, Ketocal, sparkling water) were tested. Area under the curve and Cmax for USL255 beads sprinkled onto applesauce were bioequivalent to the intact capsule (GLSM [90% CI]: AUC0-t 1.01 [0.97-1.04], AUC0-∞ 1.02 [0.98-1.05]; Cmax 1.09 [1.03-1.14]). Median Tmax was 4h earlier for USL255 sprinkled versus the intact capsule (10 vs 14 h; p=0.0018), and t1/2 was similar (84 vs 82 h, respectively). In 14-Fr G-tubes, USL255 beads diluted in Ketocal minimized bead clogging versus deionized water. Recovery of USL255 beads diluted in deionized water was nearly 100% in 16-Fr G-, 18-Fr G-, and 18-Fr J-tubes. For patients with difficulty swallowing pills, USL255 sprinkled onto applesauce offers a useful once-daily option for taking topiramate. USL255 beads were also successfully delivered in vitro through ≥14-Fr G- or J-tubes, with tube clogging minimized by portioning the dose and using glidant diluents for smaller tubes. Copyright © 2016 Upsher-Smith Laboratories, Inc. Published by Elsevier Inc. All rights reserved.
Quality of compounded hydrocortisone capsules used in the treatment of children.
Neumann, Uta; Burau, Daniela; Spielmann, Sarah; Whitaker, Martin J; Ross, Richard J; Kloft, Charlotte; Blankenstein, Oliver
2017-08-01
Due to the lack of paediatric-licensed formulations, children are often treated with individualized pharmacy-compounded adult medication. An international web-based survey about the types of medication in children with adrenal insufficiency (AI) revealed that the majority of paediatric physicians are using pharmacy-compounded medication to treat children with AI. Observations of loss of therapy control in children with congenital adrenal hyperplasia with compounded hydrocortisone capsules and regained control after prescribing a new hydrocortisone batch led to this 'real world' evaluation of pharmacy-compounded paediatric hydrocortisone capsules. Capsule samples were collected randomly from volunteering parents of treated children suffering from congenital adrenal hyperplasia from all over Germany. Analysis of net mass and hydrocortisone content by high-performance liquid chromatography with ultraviolet (HPLC-UV) detection method was performed based on the European Pharmacopeia. In a total of 61 batches that were sent, 5 batches could not be analysed because of missing dose information, insufficient number of capsules or were not possible to be evaluated. Fifty-six batches containing 1125 capsules were evaluated. 21.4% of the batches revealed insufficiency in uniformity of net mass or drug content and additional 3.6% failed because they did not contain the labelled drug. Compounded medication is a possible cause of variation of steroid doses in children with adrenal insufficiency or congenital adrenal hyperplasia, putting these vulnerable patients at risk of poor disease control and adrenal crisis. These data may apply to other individualized compounded oral medication as well, emphasizing the need for development of licensed paediatric formulations approved by regulatory authorities. © 2017 European Society of Endocrinology.
Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li
2016-11-01
In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.
Estimating the global costs of vitamin A capsule supplementation: a review of the literature.
Neidecker-Gonzales, Oscar; Nestel, Penelope; Bouis, Howarth
2007-09-01
Vitamin A supplementation reduces child mortality. It is estimated that 500 million vitamin A capsules are distributed annually. Policy recommendations have assumed that the supplementation programs offer a proven technology at a relatively low cost of around US$0.10 per capsule. To review data on costs of vitamin A supplementation to analyze the key factors that determine program costs, and to attempt to model these costs as a function of per capita income figures. Using data from detailed cost studies in seven countries, this study generated comparable cost categories for analysis, and then used the correlation between national incomes and wage rates to postulate a simple model where costs of vitamin A supplementation are regressed on per capita incomes. Costs vary substantially by country and depend principally on the cost of labor, which is highly correlated with per capita income. Two other factors driving costs are whether the program is implemented in conjunction with other health programs, such as National Immunization Days (which lowers costs), and coverage in rural areas (which increases costs). Labor accounts for 70% of total costs, both for paid staff and for volunteers, while the capsules account for less than 5%. Marketing, training, and administration account for the remaining 25%. Total costs are lowest (roughly US$0.50 per capsule) in Africa, where wages and incomes are lowest, US$1 in developing countries in Asia, and US$1.50 in Latin America. Overall, this study derives a much higher global estimate of costs of around US$1 per capsule.
Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T
1985-03-01
One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.
Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.
Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar
2013-08-27
Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to heterophagolysosomes.
Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P
2007-12-01
Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.
Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K
2018-02-01
In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi
2016-03-01
The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user-friendly software analyses of high-quality digital coaxial retro-illumination photographs.
Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation
Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi
2016-01-01
Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user-friendly software analyses of high-quality digital coaxial retro-illumination photographs. PMID:26962807
Gene expression profile of the fibrotic response in the peritoneal cavity.
Le, S J; Gongora, M; Zhang, B; Grimmond, S; Campbell, G R; Campbell, J H; Rolfe, B E
2010-01-01
The cellular response to materials implanted in the peritoneal cavity has been utilised to produce tissue for grafting to hollow smooth muscle organs (blood vessels, bladder, uterus and vas deferens). To gain insight into the regulatory mechanisms involved in encapsulation of a foreign object, and subsequent differentiation of encapsulating cells, the present study used microarray technology and real-time RT-PCR to identify the temporal changes in gene expression associated with tissue development. Immunohistochemical analysis showed that 3-7 days post-implantation of foreign objects (cubes of boiled egg white) into rats, they were encapsulated by tissue comprised primarily of haemopoietic (CD45(+)) cells, mainly macrophages (CD68(+), CCR1(+)). By day 14, tissue capsule cells no longer expressed CD68, but were positive for myofibroblast markers alpha-smooth muscle (SM) actin and SM22. In accordance with these results, gene expression data showed that early capsule (days 3-7) development was dominated by the expression of monocyte/macrophage-specific genes (CD14, CSF-1, CSF-1R, MCP-1) and pro-inflammatory mediators such as transforming growth factor (TGF-beta). As tissue capsule development progressed (days 14-21), myofibroblast-associated and pro-fibrotic genes (associated with TGF-beta and Wnt/beta-catenin signalling pathways, including Wnt 4, TGFbetaRII, connective tissue growth factor (CTGF), SMADs-1, -2, -4 and collagen-1 subunits) were significantly up-regulated. The up-regulation of genes associated with Cardiovascular and Skeletal and Muscular System Development at later time-points suggests the capacity of cells within the tissue capsule for further differentiation to smooth muscle, and possibly other cell types. The identification of key regulatory pathways and molecules associated with the fibrotic response to implanted materials has important applications not only for optimising tissue engineering strategies, but also to control deleterious fibrotic responses.
Basic ammonothermal GaN growth in molybdenum capsules
NASA Astrophysics Data System (ADS)
Pimputkar, S.; Speck, J. S.; Nakamura, S.
2016-12-01
Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).
Simulations and experiments of the growth of the “tent” perturbation in NIF ignition implosions
NASA Astrophysics Data System (ADS)
Hammel, B. A.; Tommasini, R.; Clark, D. S.; Field, J.; Stadermann, M.; Weber, C.
2016-05-01
NIF capsules are supported in the hohlraum by two thin (∼15-110 nm) Formvar films (“tent”). Highly resolved HYDRA simulations indicate that a large (∼40% peak-average) areal density (ρR) perturbation develops on the capsule during acceleration as a consequence of this support geometry. This perturbation results in a jet of dense DT and, in some cases, CH that penetrates and cools the hot spot, significantly degrading the neutron yield (∼10-20% of 1D yield). We examine “low-foot” and “high-foot” pulse shapes, tent thicknesses, and geometries. Simulations indicate that thinner tents result in a smaller pR perturbation, however, the departure angle of the tent from the capsule surface is important, with steeper angles resulting in larger perturbations.
2012-07-02
CAPE CANAVERAL, Fla. – Pepper Phillips, program manager for NASA's Ground Systems Development and Operations, addresses the audience assembled in Kennedy Space Center's Operations and Checkout Building high bay for an event marking the arrival of NASA's first space-bound Orion capsule in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
Small bowel capsule endoscopy: Where are we after almost 15 years of use?
Van de Bruaene, Cedric; De Looze, Danny; Hindryckx, Pieter
2015-01-01
The development of capsule endoscopy (CE) in 2001 has given gastroenterologists the opportunity to investigate the small bowel in a non-invasive way. CE is most commonly performed for obscure gastrointestinal bleeding, but other indications include diagnosis or follow-up of Crohn’s disease, suspicion of a small bowel tumor, diagnosis and surveillance of hereditary polyposis syndromes, Nonsteroidal anti-inflammatory drug-induced small bowel lesions and celiac disease. Almost fifteen years have passed since the release of the small bowel capsule. The purpose of this review is to offer the reader a brief but complete overview on small bowel CE anno 2014, including the technical and procedural aspects, the possible complications and the most important indications. We will end with some future perspectives of CE. PMID:25610531
2009-01-01
A 55-year-old man with myotonic dystrophy underwent phacoemulsification with IOL implantation in the right eye. 3 months after surgery, the patient showed a decreased visual acuity and an intraocular pressure (IOP) of 30 mmHg. Slit lamp examination showed a dense fibrosis of the anterior capsule with capsulorexis' shrinkage. Gonioscopy showed a closed angle. After a YAG laser iridotomy no decrease in the IOP was detected; following surgical peeling of the anterior capsule, the slit lamp showed a distended capsular bag. A YAG laser posterior capsulotomy was performed, without decrease in the IOP. Myotonic patients need to be closely followed up after cataract surgery, because in case of CBS development a prompt posterior capsulotomy could avoid more severe complications. PMID:20062622
González de Canales, M L; Muñoz-Cueto, J A; Arellano, J; García-García, A; Sarasquete, C
1996-01-01
Lymphocystis disease of the gilthead seabream, Sparus aurata from the south Atlantic coasts of Spain was studied using various cytochemical methods for nucleic acids, proteins, carbohydrates and lipids. In lymphocystis infected cells, cytoplasm and nucleoli contained RNA. DNA was restricted to the periphery of the nucleus and within the intracytoplasmatic inclusions. During the development of infected cells, proteins rich in different aminoacids were observed in the granular cytoplasm, nucleus/nucleoli, intracytoplasm inclusions and hyaline capsule. Some glycogen was observed in the cytoplasm of these cells. The intracytoplasm inclusions and the hyaline capsule also contain hydrophilic lipids, being noticeable the presence of proteins containing S-S groups. Sulphated sialoglycoproteins and glycolipids and/or phospholipids were also components of the hyaline capsule.
Gettering capsule for removing oxygen from liquid lithium systems
NASA Technical Reports Server (NTRS)
Tower, L. K.; Breitwieser, R.
1973-01-01
Capsule consisting of tantalum shell lined with tantalum screen and partially filled with lithium and pieces of yttrium is immersed in hot lithium stream. Oxygen is removed from stream by being absorbed by gettering capsule. Oxygen passes through capsule wall and into lithium inside capsule where it reacts with yttrium to form Y2O3.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-09
... withdrawing approval of a new drug application (NDA) for DURACT (bromfenac sodium) Capsules, held by Wyeth... voluntarily withdrew DURACT (bromfenac sodium) Capsules from the market. DURACT (bromfenac sodium) Capsules, a... sodium) Capsules, under Sec. 314.150(d) (21 CFR 314.150(d)). In that letter, Wyeth also waived its...
NASA Astrophysics Data System (ADS)
Sabnis, Shweta S.; Dhavale, Nilesh D.; Jadhav, Vijay. Y.; Gandhi, Santosh V.
2008-03-01
A new simple, economical, rapid, precise and accurate method for simultaneous determination of rabeprazole sodium and itopride hydrochloride in capsule dosage form has been developed. The method is based on ratio spectra derivative spectrophotometry. The amplitudes in the first derivative of the corresponding ratio spectra at 231 nm (minima) and 260 nm were selected to determine rabeprazole sodium and itopride hydrochloride, respectively. The method was validated with respect to linearity, precision and accuracy.
Sabnis, Shweta S; Dhavale, Nilesh D; Jadhav, Vijay Y; Gandhi, Santosh V
2008-03-01
A new simple, economical, rapid, precise and accurate method for simultaneous determination of rabeprazole sodium and itopride hydrochloride in capsule dosage form has been developed. The method is based on ratio spectra derivative spectrophotometry. The amplitudes in the first derivative of the corresponding ratio spectra at 231nm (minima) and 260nm were selected to determine rabeprazole sodium and itopride hydrochloride, respectively. The method was validated with respect to linearity, precision and accuracy.
Enteric-coating of pulsatile-release HPC capsules prepared by injection molding.
Macchi, E; Zema, L; Maroni, A; Gazzaniga, A; Felton, L A
2015-04-05
Capsular devices based on hydroxypropyl cellulose (Klucel® LF) intended for pulsatile release were prepared by injection molding (IM). In the present work, the possibility of exploiting such capsules for the development of colonic delivery systems based on a time-dependent approach was evaluated. For this purpose, it was necessary to demonstrate the ability of molded cores to undergo a coating process and that coated systems yield the desired performance (gastric resistance). Although no information was available on the coating of IM substrates, some issues relevant to that of commercially-available capsules are known. Thus, preliminary studies were conducted on molded disks for screening purposes prior to the spray-coating of HPC capsular cores with Eudragit® L 30 D 55. The ability of the polymeric suspension to wet the substrate, spread, start penetrating and initiate hydration/swelling, as well as to provide a gastroresistant barrier was demonstrated. The coating of prototype HPC capsules was carried out successfully, leading to coated systems with good technological properties and able to withstand the acidic medium with no need for sealing at the cap/body joint. Such systems maintained the original pulsatile release performance after dissolution of the enteric film in pH 6.8 fluid. Therefore, they appeared potentially suitable for the development of a colon delivery platform based on a time-dependent approach. Copyright © 2015 Elsevier B.V. All rights reserved.
Khan, Tareq H.; Wahid, Khan A.
2014-01-01
In this paper, a new low complexity and lossless image compression system for capsule endoscopy (CE) is presented. The compressor consists of a low-cost YEF color space converter and variable-length predictive with a combination of Golomb-Rice and unary encoding. All these components have been heavily optimized for low-power and low-cost and lossless in nature. As a result, the entire compression system does not incur any loss of image information. Unlike transform based algorithms, the compressor can be interfaced with commercial image sensors which send pixel data in raster-scan fashion that eliminates the need of having large buffer memory. The compression algorithm is capable to work with white light imaging (WLI) and narrow band imaging (NBI) with average compression ratio of 78% and 84% respectively. Finally, a complete capsule endoscopy system is developed on a single, low-power, 65-nm field programmable gate arrays (FPGA) chip. The prototype is developed using circular PCBs having a diameter of 16 mm. Several in-vivo and ex-vivo trials using pig's intestine have been conducted using the prototype to validate the performance of the proposed lossless compression algorithm. The results show that, compared with all other existing works, the proposed algorithm offers a solution to wireless capsule endoscopy with lossless and yet acceptable level of compression. PMID:25375753
Capsule endoscopy: The road ahead
Singeap, Ana-Maria; Stanciu, Carol; Trifan, Anca
2016-01-01
Since its introduction into clinical practice 15 years ago, capsule endoscopy (CE) has become the first-line investigation procedure in some small bowel pathologies, and more recently, dedicated esophageal and colon CE have expanded the fields of application to include the upper and lower gastrointestinal disorders. During this time, CE has become increasingly popular among gastroenterologists, with more than 2 million capsule examinations performed worldwide, and nearly 3000 PubMed-listed studies on its different aspects published. This huge interest in CE may be explained by its non-invasive nature, patient comfort, safety, and access to anatomical regions unattainable via conventional endoscopy. However, CE has several limitations which impede its wider clinical applications, including the lack of therapeutic capabilities, inability to obtain biopsies and control its locomotion. Several research groups are currently working to overcome these limitations, while novel devices able to control capsule movement, obtain high quality images, insufflate the gut lumen, perform chromoendoscopy, biopsy of suspect lesions, or even deliver targeted drugs directly to specific sites are under development. Overlooking current limitations, especially as some of them have already been successfully surmounted, and based on the tremendous progress in technology, it is expected that, by the end of next 15 years, CE able to perform both diagnostic and therapeutic procedures will remain the major form of digestive endoscopy. This review summarizes the literature that prognosticates about the future developments of CE. PMID:26755883
Clark, D. S.; Weber, C. R.; Smalyuk, V. A.; ...
2016-07-22
Here, current indirect drive implosion experiments on the National Ignition Facility (NIF) are believed to be strongly impacted by long wavelength perturbations driven by asymmetries in the hohlraum x-ray flux. To address this perturbation source, active efforts are underway to develop modified hohlraum designs with reduced asymmetry imprint. An alternative strategy, however, is to modify the capsule design to be more resilient to a given amount of hohlraum asymmetry. In particular, the capsule may be deliberately misshaped, or “shimmed,” so as to counteract the expected asymmetries from the hohlraum. Here, the efficacy of capsule shimming to correct the asymmetries inmore » two recent NIF implosion experiments is assessed using two-dimensional radiation hydrodynamics simulations. Despite the highly time-dependent character of the asymmetries and the high convergence ratios of these implosions, simulations suggest that shims could be highly effective at counteracting current asymmetries and result in factors of a few enhancements in neutron yields. For higher compression designs, the yield improvement could be even greater.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, D. S.; Weber, C. R.; Smalyuk, V. A.
2016-07-15
Current indirect drive implosion experiments on the National Ignition Facility (NIF) [Moses et al., Phys. Plasmas 16, 041006 (2009)] are believed to be strongly impacted by long wavelength perturbations driven by asymmetries in the hohlraum x-ray flux. To address this perturbation source, active efforts are underway to develop modified hohlraum designs with reduced asymmetry imprint. An alternative strategy, however, is to modify the capsule design to be more resilient to a given amount of hohlraum asymmetry. In particular, the capsule may be deliberately misshaped, or “shimmed,” so as to counteract the expected asymmetries from the hohlraum. Here, the efficacy ofmore » capsule shimming to correct the asymmetries in two recent NIF implosion experiments is assessed using two-dimensional radiation hydrodynamics simulations. Despite the highly time-dependent character of the asymmetries and the high convergence ratios of these implosions, simulations suggest that shims could be highly effective at counteracting current asymmetries and result in factors of a few enhancements in neutron yields. For higher compression designs, the yield improvement could be even greater.« less
Martins, Evandro; Poncelet, Denis; Rodrigues, Ramila Cristiane; Renard, Denis
2017-09-01
In the first part of this article, it was described an innovative method of oil encapsulation from dripping-inverse gelation using water-in-oil (W/O) emulsions. It was noticed that the method of oil encapsulation was quite different depending on the emulsion type (W/O or oil-in-water (O/W)) used and that the emulsion structure (W/O or O/W) had a high impact on the dripping technique and the capsules characteristics. The objective of this article was to elucidate the differences between the dripping techniques using both emulsions and compare the capsule properties (mechanical resistance and release of actives). The oil encapsulation using O/W emulsions was easier to perform and did not require the use of emulsion destabilisers. However, capsules produced from W/O emulsions were more resistant to compression and showed the slower release of actives over time. The findings detailed here widened the knowledge of the inverse gelation and gave opportunities to develop new techniques of oil encapsulation.
Colloidal micro- and nano-particles as templates for polyelectrolyte multilayer capsules.
Parakhonskiy, Bogdan V; Yashchenok, Alexey M; Konrad, Manfred; Skirtach, Andre G
2014-05-01
Colloidal particles play an important role in various areas of material and pharmaceutical sciences, biotechnology, and biomedicine. In this overview we describe micro- and nano-particles used for the preparation of polyelectrolyte multilayer capsules and as drug delivery vehicles. An essential feature of polyelectrolyte multilayer capsule preparations is the ability to adsorb polymeric layers onto colloidal particles or templates followed by dissolution of these templates. The choice of the template is determined by various physico-chemical conditions: solvent needed for dissolution, porosity, aggregation tendency, as well as release of materials from capsules. Historically, the first templates were based on melamine formaldehyde, later evolving towards more elaborate materials such as silica and calcium carbonate. Their advantages and disadvantages are discussed here in comparison to non-particulate templates such as red blood cells. Further steps in this area include development of anisotropic particles, which themselves can serve as delivery carriers. We provide insights into application of particles as drug delivery carriers in comparison to microcapsules templated on them. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jubin, Robert Thomas; Bruffey, Stephanie H.
Legacy samples composed of 85Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened, and the inner package, removed and placed in a radiological hood. The individual capsules were double bagged as they were removed from themore » inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear intact and to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 had been opened at an undetermined time in the past. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the nondestructive analysis (NDA) results, a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples, it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion. The materials contained in Capsules 2 and 5 have been examined. There appears to be a relatively uniform distribution of Kr and Rb throughout the pellets examined. The chemical composition of the pellets appears to be consistent with 5A molecular sieves. The material contained within Capsule 5 showed ~1 at. % lead. The origin of the Pb is currently indeterminate. X-ray diffraction analysis shows a significant shift from the 5A structure, most likely due to the Kr encapsulation / sintering process that occurred when the samples were made. The capsule walls were also examined and showed extensive corrosion throughout. Elemental mapping of the capsule material appeared consistent with carbon steel, while the weld material appeared consistent with a stainless steel. The interior surface of the capsule appeared to have a layer of material containing Al, Si, and Ca similar to the 5A molecular sieve. Analysis for Rb within the corrosion sites was inconclusive.« less
Yang, Hae Kyung; Ham, Dong-Sik; Park, Heon-Seok; Rhee, Marie; You, Young Hye; Kim, Min Jung; Shin, Juyoung; Kim, On-You; Khang, Gilson; Hong, Tae Ho; Kim, Ji-Won; Lee, Seung-Hwan; Cho, Jae-Hyoung; Yoon, Kun-Ho
2016-02-01
Clinical application of encapsulated islet transplantation is hindered by low biocompatibility of capsules leading to pericapsular fibrosis and decreased islet viability. To improve biocompatibility, we designed a novel chitosan-coated alginate capsules and compared them to uncoated alginate capsules. Alginate capsules were formed by crosslinking with BaCl2, then they were suspended in chitosan solution for 10 minutes at pH 4.5. Xenogeneic islet transplantation, using encapsulated porcine islets in 1,3-galactosyltransferase knockout mice, and allogeneic islet transplantation, using encapsulated canine islets in beagles, were performed without immunosuppressants. The chitosan-alginate capsules showed similar pore size, islet viability, and insulin secretory function compared to alginate capsules, in vitro. Xenogeneic transplantation of chitosan-alginate capsules demonstrated a trend toward superior graft survival (P = 0.07) with significantly less pericapsular fibrosis (cell adhesion score: 3.77 ± 0.41 vs 8.08 ± 0.05; P < 0.001) compared to that of alginate capsules up to 1 year after transplantation. Allogeneic transplantation of chitosan-alginate capsules normalized the blood glucose level up to 1 year with little evidence of pericapsular fibrotic overgrowth on graft explantation. The efficacy and biocompatibility of chitosan-alginate capsules were demonstrated in xenogeneic and allogeneic islet transplantations using small and large animal models of diabetes. This capsule might be a potential candidate applicable in the treatment of type 1 diabetes mellitus patients, and further studies in nonhuman primates are required.
Identification of a functional capsule locus in Streptococcus mitis.
Rukke, H V; Hegna, I K; Petersen, F C
2012-04-01
The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.
Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao
2014-12-01
To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without opening joint capsule can avoid joint stiffness and obtain better joint function.
Davison, James A
2015-01-01
Purpose To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. Patients and methods A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Results Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. Conclusion A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer. PMID:26355695
Astesana, Diego M; Zimmermann, Jorge A; Frizzo, Laureano S; Zbrun, María V; Blajman, Jesica E; Berisvil, Ayelén P; Romero-Scharpen, Analía; Signorini, Marcelo L; Rosmini, Marcelo R; Soto, Lorena P
2018-03-17
The aim of this study was to evaluate different production methodologies of probiotic macrocapsules with high bacterial densities destined to lactating calves. Three types of capsules containing Lactobacillus casei DSPV318T and Lactobacillus plantarum DSPV354T were prepared from an overnight culture in whey medium: (1) mixing the culture with calcium alginate and then, reincubating the capsules in whey (RC); (2) concentrating the biomass by centrifugation and mixing the pellet with calcium alginate (CC) at different concentrations with respect to the initial culture (5X and 12.5X); (3) CC with cryoprotectants: whey permeate (Per) and glycerol (Gly). Chitosan coating was evaluated. Capsules were freeze-dried and viability was assessed before freezing, after freeze-drying and every two weeks for 84 days of storage at room temperature, 4°C and -20°C. CC showed higher cell densities than RC. Storage temperature affected viability: greater viability at lower temperature. Moreover, the effect of temperature was influenced by other factors, such as capsule coating, culture neutralization and cryoprotectants. Coating improved viability at room temperature; however no effect was observed at 4°C. Culture neutralization allowed greater survival during storage. Cryoprotectants improved viability during freezing, but they also generated a positive or negative effect depending on storage temperature. The best results were: at refrigeration Gly12.5X exhibited counts above 10 9 CFU/capsule until day 70 and Per12.5X until day 56 of storage and at -20°C Gly12.5X showed counts above 10 9 CFU/capsule until the end of the study (84 days). A 10 9 CFU capsule is the daily dose per calf which would facilitate the administration of this probiotic inoculum to field animals. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Capsule injection system for a hydraulic capsule pipelining system
Liu, Henry
1982-01-01
An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.
Distribution of Collagen I, III, and IV and Laminin in the Human Liver during Prenatal Development.
Jović, Marko; Nikolić, Ivan; Todorović, Vera; Petrović, Aleksandar; Petrović, Vladimir; Mojsilović, Marijola; Denčić, Tijana
2018-06-27
In the absence of systematized data on the extracellular matrix components during prenatal liver development, the present study aimed to investigate the time of appearance and distribution of collagen types I, III, and IV and laminin. The study material included embryonic and fetal livers, aged 7-37 weeks, categorized into 3 trimesters. The material was stained using hematoxylin-eosin and immunohistochemistry methods for the identification of collagen I, III, and IV and laminin. Collagen I was detected near the end of the first trimester in the capsules and walls of interlobular veins. As the liver matures, collagen I is increasingly abundant in the capsules, portal area connective tissues, arterial walls, interlobular veins, sinusoids, and central veins. Collagen III and collagen IV appear in the middle of the first trimester in the capsules, portal areas, and walls of central veins, as well as the sinusoids particularly. In trimesters 2 and 3, these collagens are increasingly present in all the structures, but collagen IV is also present in nerve fibers. Laminin is sporadically present adjacent to the sinusoids in trimester 1, while in trimesters 2 and 3 this protein commonly appears in the walls of arteries and interlobular veins, in the basal membrane of bile ducts, and in nerve fibers. The contents of collagen I, III, and IV increase during prenatal development in the liver capsule, arterial and vein walls, sinusoids, and portal area. Laminin expression is consistent with that of the collagens with the exception that, within lobules, laminin disappears with liver maturation. © 2018 S. Karger AG, Basel.
Barbosa, Daniel C; Roupar, Dalila B; Ramos, Jaime C; Tavares, Adriano C; Lima, Carlos S
2012-01-11
Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences
NASA Astrophysics Data System (ADS)
Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki
The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.
AGR-1 Irradiation Test Final As-Run Report, Rev. 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise P.
2015-01-01
This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel processmore » development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.« less
Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie
2015-01-30
The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.
Production, deformation and mechanical investigation of magnetic alginate capsules
NASA Astrophysics Data System (ADS)
Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz
2018-02-01
In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.
Feasibility of an implantable capsule for limiting lifespan of grass carp
Thomas, R.M.; Miranda, L.E.; Kirk, J.P.
2006-01-01
The grass carp (Ctenopharyngodon idella) is an herbivorous cyprinid stocked to control undesirable aquatic vegetation. However, stocking grass carp presents several problems including complete eradication of submersed aquatic vegetation, dispersal out of the target area, adverse effects on fish communities, and damage to waterfowl habitat and native vegetation. The purpose of this research was to consider the feasibility of an implantable capsule for limiting the lifespan of grass carp. Stainless steel dowel pins were inserted into 49 fish to identify the most appropriate site to implant the capsule. The throat region along the body's longitudinal axis was identified as the most suitable location because it resulted in minimal loss over an 8-month holding period. Rotenone solutions were injected into the ventral surface between the pelvic fins to determine the lethal dosage to 95% of the population (LD 95). The LD95 for grass carp increased curvilin-early with fish weight. Four polymers that merit further evaluation in constructing the capsule are poly[bis(p-carboxyphenoxy) propane anhydride], poly[bis(p- carboxyphenoxy) hexane anhydride], poly-1-lactide, and poly(??-caprolactone) . Implants are commonly used to deliver pharmaceutical products in medical and veterinarian applications, and have been used in fish. Developing a bioerodible capsule could increase the safety and flexibility of stocking grass carp for control of aquatic plants, and may also be applicable for management of other exotic species.
Building a polysaccharide hydrogel capsule delivery system for control release of ibuprofen.
Chen, Zhi; Wang, Ting; Yan, Qing
2018-02-01
Development of a delivery system which can effectively carry hydrophobic drugs and have pH response is becoming necessary. Here we demonstrate that through preparation of β-cyclodextrin polymer (β-CDP), a hydrophobic drug molecule of ibuprofen (IBU) was incorporated into our prepared β-CDP inner cavities, aiming to improve the poor water solubility of IBU. A core-shell capsule structure has been designed for achieving the drug pH targeted and sustained release. This delivery system was built with polysaccharide polymer of Sodium alginate (SA), sodium carboxymethylcellulose (CMC) and hydroxyethyl cellulose (HEC) by physical cross-linking. The drug pH-response control release is this hydrogel system's chief merit, which has potential value for synthesizing enteric capsule. Besides, due to our simple preparing strategy, optimal conditions can be readily determined and the synthesis process can be accurately controlled, leading to consistent and reproducible hydrogel capsules. In addition, phase-solubility method was used to investigate the solubilization effect of IBU by β-CDP. SEM was used to prove the forming of core and shell structure. FT-IR and 1 H-NMR were also used to perform structural characteristics. By the technique of UV determination, the pH targeted and sustained release study were also performed. The results have proved that our prepared polysaccharide hydrogel capsule delivery system has potential applications as oral drugs delivery in the field of biomedical materials.
Pharmaceutical 3D printing: Design and qualification of a single step print and fill capsule.
Smith, Derrick M; Kapoor, Yash; Klinzing, Gerard R; Procopio, Adam T
2018-06-10
Fused deposition modeling (FDM) 3D printing (3DP) has a potential to change how we envision manufacturing in the pharmaceutical industry. A more common utilization for FDM 3DP is to build upon existing hot melt extrusion (HME) technology where the drug is dispersed in the polymer matrix. However, reliable manufacturing of drug-containing filaments remains a challenge along with the limitation of active ingredients which can sustain the processing risks involved in the HME process. To circumvent this obstacle, a single step FDM 3DP process was developed to manufacture thin-walled drug-free capsules which can be filled with dry or liquid drug product formulations. Drug release from these systems is governed by the combined dissolution of the FDM capsule 'shell' and the dosage form encapsulated in these shells. To prepare the shells, the 3D printer files (extension '.gcode') were modified by creating discrete zones, so-called 'zoning process', with individual print parameters. Capsules printed without the zoning process resulted in macroscopic print defects and holes. X-ray computed tomography, finite element analysis and mechanical testing were used to guide the zoning process and printing parameters in order to manufacture consistent and robust capsule shell geometries. Additionally, dose consistencies of drug containing liquid formulations were investigated in this work. Copyright © 2018 Elsevier B.V. All rights reserved.
Amgoth, Chander; Dharmapuri, Gangappa; Kalle, Arunasree M; Paik, Pradip
2016-03-29
Herein, new nanoporous capsules of the block co-polymers of MeO-PEG-NH-(L-GluA)10 and polycaprolactone (PCL) have been synthesized through a surfactant-free cost-effective self-assembled soft-templating approach for the controlled release of drugs and for therapeutic applications. The nanoporous polymer capsules are designed to be biocompatible and are capable of encapsulating anticancer drugs (e.g., doxorubicin hydrochloride (DOX) and imatinib mesylate (ITM)) with a high extent (∼279 and ∼480 ng μg(-1), respectively). We have developed a nanoformulation of porous MeO-PEG-NH-(L-GluA)10-PCL capsules with DOX and ITM. The porous polymer nanoformulations have been programmed in terms of the release of anticancer drugs with a desired dose to treat the leukemia (K562) and human carcinoma cells (HepG2) in vitro and show promising IC50 values with a very high mortality of cancer cells (up to ∼96.6%). Our nanoformulation arrests the cell divisions due to 'cellular scenescence' and kills the cancer cells specifically. The present findings could enrich the effectiveness of idiosyncratic nanoporous polymer capsules for use in various other nanomedicinal and biomedical applications, such as for killing cancer cells, immune therapy, and gene delivery.
NASA Astrophysics Data System (ADS)
Amgoth, Chander; Dharmapuri, Gangappa; Kalle, Arunasree M.; Paik, Pradip
2016-03-01
Herein, new nanoporous capsules of the block co-polymers of MeO-PEG-NH-(L-GluA)10 and polycaprolactone (PCL) have been synthesized through a surfactant-free cost-effective self-assembled soft-templating approach for the controlled release of drugs and for therapeutic applications. The nanoporous polymer capsules are designed to be biocompatible and are capable of encapsulating anticancer drugs (e.g., doxorubicin hydrochloride (DOX) and imatinib mesylate (ITM)) with a high extent (˜279 and ˜480 ng μg-1, respectively). We have developed a nanoformulation of porous MeO-PEG-NH-(L-GluA)10-PCL capsules with DOX and ITM. The porous polymer nanoformulations have been programmed in terms of the release of anticancer drugs with a desired dose to treat the leukemia (K562) and human carcinoma cells (HepG2) in vitro and show promising IC50 values with a very high mortality of cancer cells (up to ˜96.6%). Our nanoformulation arrests the cell divisions due to ‘cellular scenescence’ and kills the cancer cells specifically. The present findings could enrich the effectiveness of idiosyncratic nanoporous polymer capsules for use in various other nanomedicinal and biomedical applications, such as for killing cancer cells, immune therapy, and gene delivery.
Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui
2017-08-01
Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.