Sample records for scanning liver ultrasonography

  1. Immersion ultrasonography: simultaneous A-scan and B-scan.

    PubMed

    Coleman, D J; Dallow, R L; Smith, M E

    1979-01-01

    In eyes with opaque media, ophthalmic ultrasound provides a unique source of information that can dramatically affect the course of patient management. In addition, when an ocular abnormality can be visualized, ultrasonography provides information that supplements and complements other diagnostic testing. It provides documentation and differentiation of abnormal states, such as vitreous hemorrhage and intraocular tumor, as well as differentiation of orbital tumors from inflammatory causes of exophthalmos. Additional capabilities of ultrasound are biometric determinations for calculation of intraocular lens implant powers and drug-effectiveness studies. Maximal information is derived from ultrasonography when A-scan and B-scan techniques are employed simultaneously. Flexibility of electronics, variable-frequency transducers, and the use of several different manual scanning patterns aid in detection and interpretation of results. The immersion system of ultrasonography provides these features optimally.

  2. The utility of Xenon-133 liver scan in the diagnosis and management of nonalcoholic fatty liver disease.

    PubMed

    Al-Busafi, Said A; Ghali, Peter; Wong, Philip; Novales-Diaz, Javier A; Deschênes, Marc

    2012-03-01

    Nonalcoholic fatty liver disease (NAFLD) is an important and common condition affecting approximately 20% of the general population. Given the limitation of radiological investigations, diagnosis often requires a liver biopsy. To compare Xenon-133 (Xe-133) liver scanning with ultrasonography in the diagnosis of NAFLD. From January 2003 to February 2007, 258 consecutive patients with suspected NAFLD underwent Xe-133 liver scanning at Royal Victoria Hospital (Montreal, Quebec). Of these, 43 patients underwent ultrasonography and liver biopsy for the evaluation of NAFLD. Patients with other liver diseases and significant alcohol consumption were excluded. Two nuclear medicine physicians assessed liver Xe-133 uptake and measured the grade of steatosis using a standardized protocol. The degree of steatosis was determined from biopsy specimens assessed by two hepatopathologists. NAFLD was identified by liver biopsy in 35 of 43 patients (81.4%). Xe-133 scan demonstrated 94.3% sensitivity (95% CI 81.4% to 98.4%) and 87.5% specificity (95% CI 52.9% to 99.4%) for the presence of NAFLD. The positive and negative predictive values for detection of steatosis by Xe-133 scan were 97.1% (95% CI 85.1% to 99.8%) and 77.8% (95% CI 45.3% to 93.7%), respectively. The positive and negative likelihood ratios were 7.54 (95% CI 1.20 to 47.26) and 0.07 (95% CI 0.02 to 0.26), respectively. Two patients with NAFLD (5.7%) who had a negative Xe-133 scan result had histologically mild steatosis (<10%). The grade of steatosis on liver biopsy was highly correlated with the results of the Xe-133 scan (r=0.87; P<0.001). The sensitivity and specificity of ultrasound in diagnosing steatosis were 62.9% and 75%, respectively. Xe-133 liver scan proved to be a safe, reliable, noninvasive method for diagnosing and quantifying hepatic steatosis, and was superior to ultrasound.

  3. A prospective comparative assessment of the accuracy of the FibroScan in evaluating liver steatosis

    PubMed Central

    Park, Eui Ju; Jang, Jae Young; Jeong, Soung Won; Lee, Sae Hwan; Kim, Sang Gyune; Cha, Sang-Woo; Kim, Young Seok; Cho, Young Deok; Kim, Hong Soo; Kim, Boo Sung; Jin, So Young; Park, Suyeon

    2017-01-01

    Background/aims Recent studies have demonstrated the utility of the FibroScan® device in diagnosing liver steatosis, but its usefulness has not been thoroughly appraised. We investigated the usefulness of the controlled attenuation parameter (CAP) in detecting and quantifying liver steatosis. Methods A prospective analysis was applied to 79 chronic liver disease patients who underwent a liver biopsy, a FibroScan investigation, ultrasonography, and hepatic steatosis index (HSI). The presence and degree of steatosis as measured by the FibroScan device, ultrasonography and HSI were compared with the results for the liver biopsy tissue. Results There was substantial concordance between the liver biopsy results and the CAP as evaluated by the kappa (κ) index test for detecting liver steatosis (κCAP = 0.77, P<0.001; κultrasonography = 0.60, P<0.001; κHSI = 0.47, P<0.001). The areas under the receiver operating characteristic curve (AUROCs) of the CAP, ultrasonography, and HSI were 0.899 [95% confidence interval (CI) = 0.826–0.972)], 0.859 (95% CI = 0.779–0.939), and 0.766 (95% CI = 0.655–0.877), respectively. The optimal CAP cutoff value for differentiating between normal and hepatic steatosis was 247 dB/m, which produced sensitivity and specificity values of 91.9% and 85.7%, respectively, as well as a positive predictive value of 85.0% and a negative predictive value of 92.3%. Conclusion The CAP produces results that are highly concordant with those of a liver biopsy in detecting steatosis. Therefore, the CAP is a noninvasive and reliable tool for evaluating liver steatosis, even in the early stages. PMID:28813448

  4. Periportal fibrosis and other liver ultrasonography findings in vinyl chloride workers

    PubMed Central

    Maroni, M; Mocci, F; Visentin, S; Preti, G; Fanetti, A

    2003-01-01

    Aims: To investigate the presence of liver lesions and their relation with vinyl chloride monomer (VCM) exposure or other personal risk factors, in workers involved in the production of VCM and polyvinyl chloride (PVC). Methods: A liver ultrasonography examination was conducted in 757 workers, some of whom had long standing service in the production of VCM and PVC. The study involved: assessment of individual past and present VCM exposure of each worker; collection of past personal health history, lifestyle and personal data; routine liver function tests; and liver ultrasonography. Results: No cases of liver malignancies were detected. Angiomas and liver cysts were found with a frequency of occurrence within the expected range of the general population. The main findings consisted of hepatomegaly (34.7%), steatosis (31.8%), and periportal fibrosis (16.0%). A logistic regression analysis indicated that hepatomegaly and steatosis were associated with obesity and lipid metabolism disturbances and not with VCM exposure. Periportal fibrosis, in addition to constitutional or dietary factors, was shown to be associated with VCM exposure, but only when maximum exposure in the subject's history had been at least 200 ppm as a yearly average; no effects were observed at 50 ppm or below. Conclusions: Workers exposed to 200 ppm VCM for at least one year have a fourfold increased risk of developing periportal liver fibrosis. Liver ultrasonography is a suitable and important diagnostic test for the medical surveillance of vinyl chloride workers. PMID:12499459

  5. Endoscopic ultrasonography predicts early esophageal variceal bleeding in liver cirrhosis: A case report.

    PubMed

    Men, Changjun; Zhang, Guoliang

    2017-04-01

    Bleeding esophageal and gastric varices constitute a serious complication in liver cirrhosis. Previous studies have shown that endoscopic ultrasonography (EUS) can be used to predict early esophageal variceal bleeding in liver cirrhosis. We report a case of a 46-year-old man with hepatitis B liver cirrhosis (CTP score, 5; Child-Pugh class, A) who was admitted to our hospital due to a decreased appetite lasting 1 week. He was initially diagnosed with decompensated hepatitis B cirrhosis; an abdominal computed tomography (CT) scan indicated a diagnosis of liver cirrhosis and portal hypertension (PHT). Common endoscopic examination showed no evidence of gastroesophageal varices; EUS revealed distinct varices of the esophageal and gastric veins. Six months after discharge, the patient was rehospitalized because of upper gastrointestinal bleeding. Endoscopic ligation was implemented as well as esophageal varices loop ligature (EVL). Six months later, EUS showed obvious collateral and perforator veins. We should strongly recommend that patients with liver cirrhosis undergo EUS in addition to a routine endoscopic examination. EUS can play an important role in evaluating the risk for bleeding in PHT and can be used to assess the efficacy of EVL.

  6. Doppler ultrasonography in living donor liver transplantation recipients: Intra- and post-operative vascular complications

    PubMed Central

    Abdelaziz, Omar; Attia, Hussein

    2016-01-01

    Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure. PMID:27468207

  7. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    PubMed

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Evaluation of acute radiation optic neuropathy by B-scan ultrasonography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovato, A.A.; Char, D.H.; Quivey, J.M.

    1990-09-15

    We studied the accuracy of B-scan ultrasonography to diagnose radiation-induced optic neuropathy in 15 patients with uveal melanoma. Optic neuropathy was diagnosed by an observer masked as to clinical and photographic data. We analyzed planimetry area measurements of the retrobulbar nerve before and after irradiation. The retrobulbar area of the optic nerve shadow on B-scan was quantitated with a sonic digitizer. Increased optic nerve shadow area was confirmed in 13 of 15 patients who had radiation optic neuropathy (P less than .004). The correct diagnosis was confirmed when the results of ultrasound were compared to fundus photography and fluorescein angiography.more » In 13 patients there was acute radiation optic neuropathy. Two patients did not show an enlarged retrobulbar optic nerve, and the clinical appearance suggested early progression to optic atrophy. Ultrasonography documents the enlargement of the optic nerve caused by acute radiation changes.« less

  9. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    PubMed

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  10. Transient elastography (FibroScan®) with controlled attenuation parameter in the assessment of liver steatosis and fibrosis in patients with nonalcoholic fatty liver disease - Where do we stand?

    PubMed Central

    Mikolasevic, Ivana; Orlic, Lidija; Franjic, Neven; Hauser, Goran; Stimac, Davor; Milic, Sandra

    2016-01-01

    Non-alcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis (laboratory tests and ultrasonography) or cannot be applied as a screening procedure (liver biopsy). Among the non-invasive tests, transient elastography (FibroScan®, TE) with controlled attenuation parameter (CAP) has demonstrated good accuracy in quantifying the levels of liver steatosis and fibrosis in patients with NAFLD, the factors associated with the diagnosis and NAFLD progression. The method is fast, reliable and reproducible, with good intra- and interobserver levels of agreement, thus allowing for population-wide screening and disease follow-up. The initial inability of the procedure to accurately determine fibrosis and steatosis in obese patients has been addressed with the development of the obese-specific XL probe. TE with CAP is a viable alternative to ultrasonography, both as an initial assessment and during follow-up of patients with NAFLD. Its ability to exclude patients with advanced fibrosis may be used to identify low-risk NAFLD patients in whom liver biopsy is not needed, therefore reducing the risk of complications and the financial costs. PMID:27621571

  11. Assessment of liver volume with computed tomography and comparison of findings with ultrasonography.

    PubMed

    Bora, Aydın; Alptekin, Cem; Yavuz, Alpaslan; Batur, Abdussamet; Akdemir, Zülküf; Berköz, Mehmet

    2014-12-01

    In this study, we aimed to investigate the impact of non-alcoholic hepatic steatosis on the liver volume. As investigating hepatic steatosis, we utilized computed tomography (CT) to determine the degree of steatosis and we utilized hepatobiliary ultrasonography (USG) for densitometry and correlation. As hepatosteatosis group, 35 patients over 18 years of age and whose abdominal CT scans were requested by several clinics and performed routinely were included in this study, and as control group, 40 healthy subjects without hepatosteatosis (clinically and radiologically) and correlated with hepatosteatosis group in terms of age and gender were included in this study. CT densitometry and liver attenuation index (LAI) of all individuals who participated in our study were calculated, and contrast images of patients were transferred to CT-Volume Software (Siemens Syngo Multimodality Workplace; Version VE52A). In this study, interactive and automated volume measurement techniques were used together. The volumes were measured separately in patient and control group. In this study for each stage in USG, there was found a direct correlation in terms of LAI and volume, and this correlation was statistically significant (p < 0.01). Furthermore, statistical significance between size and USG stage draws attention (p < 0.05). A significance relationship between USG stage and age could not be determined. As a result, we have reached the conclusion that CT densitometry can be used as an assistive technique along with USG to determine the degree of steatosis in the non-alcoholic fatty liver disease, and there is a positive linear correlation between the liver size and volume, and liver volume increases in the non-alcoholic fatty liver disease.

  12. B-scan ultrasonography for the detection of space-occupying ocular masses.

    PubMed

    Miller, W W; Cartee, R E

    1985-07-01

    A noninvasive technique, B-scan ultrasonography, was used to obtain detailed cross-sectional images of ocular and orbital structure and form. When a low-frequency probe (5 MHz) was used, tissue penetration was excellent; however, axial resolution was limited. The technique was used in a study of 2 cats and 1 dog. The use of low-frequency B-scan ultrasound should aid in the diagnostic examinations of space-occupying masses in the posterior portion of the ocular bulb and the orbit.

  13. Ultrasonography of the liver and kidneys of healthy camels (Camelus dromedarius).

    PubMed

    Tharwat, Mohamed; Al-Sobayil, Fahd; Ali, Ahmed; Buczinski, Sébastien

    2012-12-01

    This study describes the ultrasonography of the liver and kidneys of healthy camels (Camelus dromedarius). Images of the liver were obtained from the 11th to 5th intercostal spaces (ICSs). The distance between the dorsal liver margin and the midline of the back was shortest (39.1 ± 7.4 cm) at the 11th ICS and increased cranially to 5th ICS. The size of the liver was largest at the 9th ICS and smallest at the 5th ICS. In 6 camels the right kidney was visualized from the 10th and 11th ICSs and upper right flank and in the 10th and 11th ICSs in the remaining 16 camels. In all camels, the left kidney was imaged from the caudal left flank. In 21 camels, the differentiation between the renal cortex and medulla was clearly visible in the ultrasonograms. Ultrasonographic description of the liver and kidneys provides a basic reference for diagnosing hepatic and renal disorders in camels.

  14. Effect of ultrasonography surveillance in patients with liver cancer: a population-based longitudinal study

    PubMed Central

    Chiang, Jui-Kun; Chih-Wen, Lin; Kao, Yee-Hsin

    2017-01-01

    Objective Liver cancer is a growing global public health problem. Ultrasonography is an imaging tool widely used for the early diagnosis of liver cancer. However, the effect of ultrasonography surveillance (US) on the survival of patients with liver cancer is unknown. Therefore, this study examined the association between survival and US frequency during the 2 years preceding patients’ liver cancer diagnosis. Methods This population-based longitudinal study was conducted in Taiwan, a region with high liver cancer incidence, by using the National Health Insurance Research Database. We compared survival between patients who received US three times or more (≥3 group) and less than three times (<3 group) during the 2 years preceding their liver cancer diagnosis, and identified the predictors for the ≥3 group. Results This study enrolled 4621 patients with liver cancer who had died between 1997 and 2010. The median survival rate was higher in the ≥3 group (1.42 years) than in the <3 group (0.51 years). Five-year survival probability was also significantly higher in the ≥3 group (14.4%) than in the <3 group (7.7%). The multivariate logistic regression results showed that the three most common positive predictors for receiving three or more US sessions were indications of viral hepatitis, gallbladder diseases and kidney–urinary–bladder diseases; the most common negative predictors for receiving three or more US sessions were male sex and indications of abdominal pain. Conclusion Patients with liver cancer who received US three times or more during the 2 years preceding their liver cancer diagnosis exhibited a higher 5-year survival probability. PMID:28645973

  15. Ultrasonography of the liver and kidneys of healthy camels (Camelus dromedarius)

    PubMed Central

    Tharwat, Mohamed; Al-Sobayil, Fahd; Ali, Ahmed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonography of the liver and kidneys of healthy camels (Camelus dromedarius). Images of the liver were obtained from the 11th to 5th intercostal spaces (ICSs). The distance between the dorsal liver margin and the midline of the back was shortest (39.1 ± 7.4 cm) at the 11th ICS and increased cranially to 5th ICS. The size of the liver was largest at the 9th ICS and smallest at the 5th ICS. In 6 camels the right kidney was visualized from the 10th and 11th ICSs and upper right flank and in the 10th and 11th ICSs in the remaining 16 camels. In all camels, the left kidney was imaged from the caudal left flank. In 21 camels, the differentiation between the renal cortex and medulla was clearly visible in the ultrasonograms. Ultrasonographic description of the liver and kidneys provides a basic reference for diagnosing hepatic and renal disorders in camels. PMID:23729824

  16. Tactile sensor is useful for estimating liver hardness and liver fibrosis compared with ultrasonography and computed tomography.

    PubMed

    Suzuki, Satoshi; Watanabe, Yohei; Yazawa, Takashi; Ishigame, Teruhide; Sassa, Motoki; Monma, Tomoyuki; Takawa, Tadashi; Kumamoto, Kensuke; Nakamura, Izumi; Ohoki, Shinji; Hatakeyama, Yuichi; Sakuma, Hiroshi; Ono, Toshiyuki; Omata, Sadao; Takenoshita, Seiichi

    2014-01-01

    We examined whether conventional ultrasonography (US) and computed tomography (CT) were useful to evaluate liver hardness and hepatic fibrosis by comparing the results with those obtained by a tactile sensor using rats with liver fibrosis. We used 44 Wistar rats in which liver fibrosis was induced by intraperitoneal administration of thioacetamide. The CT and US values of each liver were measured before laparotomy. After laparotomy, a tactile sensor was used to measure liver hardness. We prepared Azan stained sections of each excised liver specimen and calculated the degree of liver fibrosis (HFI: hepatic fibrosis index) by computed color image analysis. The stiffness values and HFI showed a positive correlation (r=0.690, p<0.001), as did the tactile values and HFI (r=0.709, p<0.001).In addition, the stiffness and tactile values correlated positively with each other (r=0.814, p<0.001). There was no correlation between the CT values and HFI, as well as no correlation between the US values and HFI. We confirmed that it was difficult to evaluate liver hardness and HFI by CT or US examination, and considered that, at present, a tactile sensor is useful method for evaluating HFI.

  17. Effect of ultrasonography surveillance in patients with liver cancer: a population-based longitudinal study.

    PubMed

    Chiang, Jui-Kun; Chih-Wen, Lin; Kao, Yee-Hsin

    2017-06-23

    Liver cancer is a growing global public health problem. Ultrasonography is an imaging tool widely used for the early diagnosis of liver cancer. However, the effect of ultrasonography surveillance (US) on the survival of patients with liver cancer is unknown. Therefore, this study examined the association between survival and US frequency during the 2 years preceding patients' liver cancer diagnosis. This population-based longitudinal study was conducted in Taiwan, a region with high liver cancer incidence, by using the National Health Insurance Research Database. We compared survival between patients who received US three times or more (≥3 group) and less than three times (<3 group) during the 2 years preceding their liver cancer diagnosis, and identified the predictors for the ≥3 group. This study enrolled 4621 patients with liver cancer who had died between 1997 and 2010. The median survival rate was higher in the ≥3 group (1.42 years) than in the <3 group (0.51 years). Five-year survival probability was also significantly higher in the ≥3 group (14.4%) than in the <3 group (7.7%). The multivariate logistic regression results showed that the three most common positive predictors for receiving three or more US sessions were indications of viral hepatitis, gallbladder diseases and kidney-urinary-bladder diseases; the most common negative predictors for receiving three or more US sessions were male sex and indications of abdominal pain. Patients with liver cancer who received US three times or more during the 2 years preceding their liver cancer diagnosis exhibited a higher 5-year survival probability. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Usefulness of intraoperative ultrasonography in liver resections due to colon cancer metastasis.

    PubMed

    Lucchese, Angélica Maria; Kalil, Antônio Nocchi; Schwengber, Alex; Suwa, Eiji; Rolim de Moura, Gabriel Garcia

    2015-08-01

    Intraoperative ultrasonography (IOUS) of the liver has been used both as an aid for intraoperative anatomical definition and for the detection of new lesions. The present study aimed to evaluate the impact of IOUS and to identify factors that can predict the detection of new lesions intraoperatively. In this observational and prospective study, with a cross-sectional design, patients with colorectal cancer metastases who underwent hepatectomy were selected. Abdominal computed tomography, magnetic resonance imaging, and positron emission tomography were the preoperative evaluation tests. All patients underwent IOUS performed by the same surgeon. The intraoperative findings were compared with the preoperative tests results. In total, 56 hepatectomies were evaluated. Half of the patients were men, with a mean age of 57 (30-85) years. New lesions were found intraoperatively in 12 patients (21.4% of cases) and were detected on both palpation and ultrasonography in 11 of these patients. Ultrasonography helped to revise the surgical plans by providing additional information in 35.7% of cases. On multivariate analysis, the presence of more than 4 preoperative nodules was predictive of the intraoperative occurrence of new lesions. IOUS remains the only way to evaluate the relationships between tumors, liver vascular structures, and bile ducts intraoperatively. Alone, IOUS was not useful for identifying new lesions intraoperatively, as all new lesions were also detected on palpation. The number of lesions diagnosed on preoperative tests influenced the probability of identifying new lesions intraoperatively. There may be additional influential factors. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  19. Using ultrasonography to monitor liver blood flow for liver transplant from donors supported on extracorporeal membrane oxygenation.

    PubMed

    Zhu, Xian-Sheng; Wang, Sha-Sha; Cheng, Qi; Ye, Chuang-Wen; Huo, Feng; Li, Peng

    2016-02-01

    Extracorporeal membrane oxygenation (ECMO) has been used to support brain-dead donors for liver procurement. This study investigated the potential role of ultrasonographic monitoring of hepatic perfusion as an aid to improve the viability of liver transplants obtained from brain-dead donors who are supported on ECMO. A total of 40 brain-dead patients maintained on ECMO served as the study population. Hepatic blood flow was monitored using ultrasonography, and perioperative optimal perfusion was maintained by calibrating ECMO. Liver function tests were performed to assess the viability of the graft. The hepatic arterial blood flow was well maintained with no significant changes observed before and after ECMO (206 ± 32 versus 241 ± 45 mL/minute; P = 0.06). Similarly, the portal venous blood flow was also maintained throughout (451 ± 65 versus 482 ± 77 mL/minute; P = 0.09). No significant change in levels of total bilirubin, alanine transaminase, and lactic acid were reported during ECMO (P = 0.17, P = 0.08, and P = 0.09, respectively). Before the liver is procured, ultrasonographic monitoring of hepatic blood flow could be a valuable aid to improve the viability of a liver transplant by allowing for real-time calibration of ECMO perfusion in brain-dead liver donors. In our study, ultrasonographic monitoring helped prevent warm ischemic injury to the liver graft by avoiding both overperfusion and underperfusion of the liver. © 2015 American Association for the Study of Liver Diseases.

  20. Perivascular epithelioid cell tumor (PEComa) of the liver diagnosed by contrast-enhanced ultrasonography.

    PubMed

    Akitake, Reiko; Kimura, Hiroyuki; Sekoguchi, Satoru; Nakamura, Hideki; Seno, Hiroshi; Chiba, Tsutomu; Fujimoto, Sotaro

    2009-01-01

    Perivascular epithelioid cell (PEC) is a unique cell which expresses both myogenic and melanocytic markers, and forms PEComa. A 36-year-old woman presented with a 35 mm-diameter liver tumor. MRI showed poor fat component in the tumor. Contrast-enhanced ultrasonography using the newly developed enhancing reagent, Sonazoid, clearly demonstrated early-phase enhancement of the tumor and rapid drainage of the reagent to veins, suggesting a PEComa. Lateral segmentectomy of the liver was performed. Histologically, epithelioid tumor cells around the vessels were immunostained with both HMB-45 and alpha-smooth muscle actin, confirming the diagnosis of PEComa. No recurrence has been found for 18 months following the operation.

  1. Contrast-enhanced ultrasonography for the evaluation of liver fibrosis after biliary obstruction.

    PubMed

    Shin, Hyun Joo; Chang, Eun Young; Lee, Hye Sun; Hong, Jung Hwa; Park, Gyuri; Kim, Hyun Gi; Kim, Myung-Joon; Lee, Mi-Jung

    2015-03-07

    To investigate perfusion change in contrast-enhanced ultrasonography (CEUS) to evaluate liver fibrosis based on biliary obstruction using an animal model. New Zealand white rabbits (3-4 kg) underwent bile duct ligation to form a biliary obstruction model. We performed liver CEUS and laboratory tests on the day before the operation (day 0) and every 7 postoperative days until the rabbits were sacrificed. After CEUS, signal intensity of liver parenchyma with a time-intensity curve was analyzed. Perfusion parameters were automatically calculated from region-of-interests, including peak signal intensity, mean transit time, area under the curve and time to peak. Histological grades of liver fibrosis were assessed according to the Metavir score system immediately after sacrifice. Generalized estimating equations were used to analyze the association between liver fibrosis grades and perfusion parameters for statistical analysis. The perfusion parameters were measured on the last day and the difference between day 0 and the last day were evaluated. From the nine rabbits, histological grades of liver fibrosis were grade 1 in one rabbit, grade 2 and 3 in three rabbits each, and grade 4 in two rabbits. Among the four CEUS parameters, only the peak signal intensity measured on the last day demonstrated a significant association with liver fibrosis grades (OR = 1.392, 95%CI: 1.114-1.741, P = 0.004). The difference in peak signal intensity between day 0 and the last day also demonstrated an association with liver fibrosis (OR = 1.191, 95%CI: 0.999-1.419, P = 0.051). The other parameters tested, including mean transit time, area under the curve, and time to peak, showed no significant correlation with liver fibrosis grades. This animal study demonstrates that CEUS can be used to evaluate liver fibrosis from biliary obstruction using peak signal intensity as a parameter.

  2. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients.

    PubMed

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-04-01

    Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions.

  3. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients

    PubMed Central

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-01-01

    Abstract Background: Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Methods: Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. Results: The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. Conclusions: For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Translational Impacts: Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions. PMID:28445256

  4. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    PubMed

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  5. CT Scanning in Identification of Sheep Cystic Echinococcosis.

    PubMed

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei; Bao, Yongxing; Li, Haitao

    2017-01-01

    We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung ( R = 0.770, P < 0.001). CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure.

  6. CT Scanning in Identification of Sheep Cystic Echinococcosis

    PubMed Central

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei

    2017-01-01

    Objective We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Methods Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Results Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung (R = 0.770, P < 0.001). Conclusions CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure. PMID:29082246

  7. Cling film as a barrier against CJD in corneal contact A-scan ultrasonography.

    PubMed

    Rani, Asha; Dunne, Mark C M; Barnes, Derek A

    2003-01-01

    To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another.

  8. [Intraoperative ultrasonography during laparoscopic surgery].

    PubMed

    Alecu, L; Lungu, C; Pascu, A; Costan, I; Corodeanu, G; Deacu, A; Marin, A

    2000-01-01

    Of this study is the introduction and the results evaluation of laparoscopic ultrasonography performed. We realize a prospective study about laparoscopic ultrasonography performed in 37 cases with laparoscopic surgical treatment. The Aloka SSD 2000 mobile scanner is used. This system make possible the use of an linear-array transducer, with mechanical flexibility and availability of Doppler analysis. Most frequently we used intraoperative ultrasonography in laparoscopic cholecystectomy as an alternative for cholangiography to exclude CBD pathology. Because of various surgical pathology with laparoscopic approach, the laparoscopic ultrasonography utilization range was vastly. In all the cases we could performed the laparoscopic ultrasonography. In 6 of 27 cases with laparoscopic cholecystectomy we found pathological disorders of bile ducts. CBD with diameter found between 5-12 mm. We properly saw the distal segment of CBD in 23 cases (89.2%), and common hepatic duct in 26 cases (97.3%). The quality of visualization was very good in 21 cases (83.8%) and moderate in 6 cases (16.2%). We easy identify CBD stones and we successfully used Doppler color mode in differentiating vascular from non-vascular from non-vascular structures. Laparoscopic ultrasonography performed in a case with left colon cancer excluded liver metastasis and lymph nodes metastasis. 1. Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography; 2. Laparoscopic ultrasonography is a simple and very efficient intraoperative examination procedure; 3. Laparoscopic ultrasonography is the technique to choose in CBD intraoperative exploration; 4. Laparoscopic ultrasonography improve abdominal malignancy exploration, thus modifying therapeutic decisions; 5. Color Doppler mode guides the surgeon's steps in difficult directions.

  9. Finding of biliary fascioliasis by endoscopic ultrasonography in a patient with eosinophilic liver abscess.

    PubMed

    Behzad, Catherine; Lahmi, Farhad; Iranshahi, Majid; Mohammad Alizadeh, Amir Houshang

    2014-09-01

    Fascioliasis is an endemic zoonotic disease in Iran. It occurs mainly in sheep-rearing areas of temperate climates, but sporadic cases have been reported from many other parts of the world. The usual definitive host is the sheep. Humans are accidental hosts in the life cycle of Fasciola. Typical symptoms may be associated with fascioliasis, but in some cases diagnosis and treatment may be preceded by a long period of abdominal pain and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 6 months, with imaging suggesting liver abscess and normal biliary ducts. The patient had no eosinophilia with negative stool examinations, so she was initially treated with antibiotics for liver abscess. Her clinical condition as well as follow-up imagings showed appropriate response after antibiotic therapy. Finally, endoscopic ultrasonography revealed Fasciola hepatica, which was then extracted with endoscopic retrograde cholangiopancreatography.

  10. Comparison of radiography and ultrasonography in the detection of lung and liver cysts in cattle and buffaloes

    PubMed Central

    Kumar, Ashwani; Saini, Narinder Singh; Mohindroo, Jitender; Singh, Balbir Bagicha; Sangwan, Vandana; Sood, Naresh Kumar

    2016-01-01

    Aim: Echinococcosis is the major cause of lung and liver cysts in ruminants. This study compared usefulness of radiography and ultrasonography (USG) in the detection of lung and/or liver cysts in sick bovine animals. The study also worked out cooccurrence of lung and liver cysts, and whether these cysts were primary cause of sickness or not. Materials and Methods: This study was conducted on 45 sick bovine (37 buffaloes and 8 cattle) suffering from lung and liver cysts. A complete history of illness and clinical examination was carried out. Lateral radiographs of chest and reticular region were taken. In radiographically positive or suspected cases of cysts, USG of the lung and liver region was done. Depending on the location of cyst and clinical manifestations of the animal, the cysts were categorized as primary or secondary causes of sickness. Results: Using either imaging technique, it was observed that 46.7% of the animals had both lung and liver cysts, whereas 33.3% had only lung and 20% had only liver cyst. Cysts were identified as primary cause of sickness in 31.1% animals only. For diagnosing lung cysts, radiography (71.1%) and USG (62.2%) had similar diagnostic utility. However, for detecting liver cysts, USG was the only imaging tool. Conclusion: The lung and liver cysts, depending on their number and size may be a primary cause of sickness in bovine. Radiography and USG are recommended, in combination, as screening tools to rule out echinococcosis. PMID:27847421

  11. The measurement of liver fat from single-energy quantitative computed tomography scans

    PubMed Central

    Cheng, Xiaoguang; Brown, J. Keenan; Guo, Zhe; Zhou, Jun; Wang, Fengzhe; Yang, Liqiang; Wang, Xiaohong; Xu, Li

    2017-01-01

    Background Studies of soft tissue composition using computed tomography (CT) scans are often semi-quantitative and based on Hounsfield units (HU) measurements that have not been calibrated with a quantitative CT (QCT) phantom. We describe a study to establish the water (H2O) and dipotassium hydrogen phosphate (K2HPO4) basis set equivalent densities of fat and fat-free liver tissue. With this information liver fat can be accurately measured from any abdominal CT scan calibrated with a suitable phantom. Methods Liver fat content was measured by comparing single-energy QCT (SEQCT) HU measurements of the liver with predicted HU values for fat and fat-free liver tissue calculated from their H2O and K2HPO4 equivalent densities and calibration data from a QCT phantom. The equivalent densities of fat were derived from a listing of its constituent fatty acids, and those of fat-free liver tissue from a dual-energy QCT (DEQCT) study performed in 14 healthy Chinese subjects. This information was used to calculate liver fat from abdominal SEQCT scans performed in a further 541 healthy Chinese subjects (mean age 62 years; range, 31–95 years) enrolled in the Prospective Urban Rural Epidemiology (PURE) Study. Results The equivalent densities of fat were 941.75 mg/cm3 H2O and –43.72 mg/cm3 K2HPO4, and for fat-free liver tissue 1,040.13 mg/cm3 H2O and 21.34 mg/cm3 K2HPO4. Liver fat in the 14 subjects in the DEQCT study varied from 0–17.9% [median: 4.5%; interquartile range (IQR): 3.0–7.9%]. Liver fat in the 541 PURE study subjects varied from –0.3–29.9% (median: 4.9%; IQR: 3.4–6.9%). Conclusions We have established H2O and K2HPO4 equivalent densities for fat and fat-free liver tissue that allow a measurement of liver fat to be obtained from any abdominal CT scan acquired with a QCT phantom. Although radiation dose considerations preclude the routine use of QCT to measure liver fat, the method described here facilitates its measurement in patients having CT scans

  12. CONSUMER PREFERENCES FOR SCANNING MODALITY TO DIAGNOSE FOCAL LIVER LESIONS.

    PubMed

    Whitty, Jennifer; Filby, Alexandra; Smith, Adam B; Carr, Louise M

    2015-01-01

    Differences in the process of using liver imaging technologies might be important to patients. This study aimed to investigate preferences for scanning modalities used in diagnosing focal liver lesions. A discrete choice experiment was administered to 504 adults aged 25 ≥years. Respondents made repeated choices between two hypothetical scans, described according to waiting time for scan and results, procedure type, the chance of minor side-effects, and whether further scanning procedures were likely to be required. Choice data were analyzed using mixed-logit models with respondent characteristics used to explain preference heterogeneity. Respondents preferred shorter waiting times, the procedure to be undertaken with a handheld scanner on a couch instead of within a body scanner, no side-effects, and no follow–up scans (p≤.01). The average respondent was willing to wait an additional 2 weeks for the scan if it resulted in avoiding side-effects, 1.5 weeks to avoid further procedures or to be told the results immediately, and 1 week to have the scan performed on a couch with a handheld scanner. However, substantial heterogeneity was observed in the strength of preference for desirable imaging characteristics. An average individual belonging to a general population sub–group most likely to require imaging to characterize focal liver lesions in the United Kingdom would prefer contrast–enhanced ultrasound over magnetic resonance imaging or computed tomography. Insights into the patient perspective around differential characteristics of imaging modalities have the potential to be used to guide recommendations around the use of these technologie

  13. Assessment of liver size by ultrasonography.

    PubMed

    Patzak, Monika; Porzner, Marc; Oeztuerk, Suemeyra; Mason, Richard Andrew; Wilhelm, Manfred; Graeter, Tilmann; Kratzer, Wolfgang; Haenle, Mark Martin; Akinli, Atilla Serif

    2014-09-01

    To determine liver span sonographically in a randomly selected population sample and identify factors that affect liver size. A total of 1,789 subjects (963 females, 826 males; mean age 41.8 ± 12.8 years) underwent sonographic examination of the liver in the midclavicular line to determine liver span. Subjects underwent physical examination and blood tests and completed a standardized interview questionnaire. The average liver span in the midclavicular line for the overall collective was 15.0 ± 1.5 cm; the average for females was 14.9 ± 1.6 cm and 15.1 ± 1.5 cm for males. Liver span exceeded 16 cm in 24.3% of subjects. Results of the multivariate analysis showed that, of the factors potentially influencing liver span, gender, age, body mass index, body height, fatty liver (p < 0.0001), waist-to-hip ratio (p = 0.015), and metabolic syndrome (p = 0.032) are significant. By contrast, diabetes mellitus, alcohol consumption, tobacco consumption, physical activity, and laboratory findings showed no influence. Sonographic measurement of liver span in the midclavicular line is a simple method for routine clinical use. Gender, age, body mass index, waist-to-hip ratio, body height, hepatic steatosis, and metabolic syndrome are factors associated with liver span. © 2014 Wiley Periodicals, Inc.

  14. Is Routine Intraoperative Contrast-Enhanced Ultrasonography Useful During Whole Liver Transplantation?

    PubMed

    Golse, Nicolas; Santoni, Simone; Karam, Vincent; Ciacio, Oriana; Pittau, Gabriella; Allard, Marc-Antoine; Cherqui, Daniel; Sa Cunha, Antonio; Adam, René; Castaing, Denis; Vibert, Eric

    2018-05-01

    Vascular complications following liver transplantation (LT) may result from technical deficiencies. Intraoperative diagnosis remains challenging but can prevent serious delayed complications. Intraoperative Doppler ultrasonography (IOUS) represents the gold standard for imaging, although it requires radiological skills. Contrast-enhanced ultrasonography has been reported during postoperative assessments, but never intraoperatively (CE-IOUS). The aim of this study was to assess the feasibility of routine CE-IOUS, to evaluate its impact on surgical strategy and its usefulness. All 553 whole LTs performed in our tertiary centre between 01/2010 and 12/2014 were reviewed. We compared perioperative outcomes and long-term survival in IOUS (n = 370) versus CE-IOUS (n = 103) groups. Secondarily, the seven cases where the two imaging findings conflicted (CE+ Group) were matched 1:2 and compared with an exclusively IOUS procedure (CE- Group, n = 14) to assess the consequences of a specific CE-guided strategy. CE-IOUS assessments were successful in 100% of cases, without any adverse effects. Vascular complications and patient/graft survival rates were identical in the IOUS and CE-IOUS groups (p = 0.65, 0.95 and 0.86, respectively). CE-IOUS confirmed IOUS findings in 93% of cases (n = 96) and led to the realization of an additional procedure (median arcuate ligament lysis) and six conservative strategies despite poor arterial (n = 5) or venous flow (n = 1) under Doppler analysis. The CE+ and CE- groups presented statistically identical perioperative and long-term outcomes. This study demonstrated the feasibility of CE-IOUS during whole LT. However, we failed to demonstrate any advantages of CE-IOUS over IOUS. Therefore, IOUS currently remains the gold-standard imaging technique for the intraoperative assessment of vascular patency.

  15. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    PubMed

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  16. Use of contrast ultrasonography in the diagnosis of metastatic feline visceral haemangiosarcoma.

    PubMed

    Webster, Natalie; Holloway, Andrew

    2008-08-01

    A 12-year-old cat was presented for investigation of weight loss and inappetence. Radiography and conventional grey-scale ultrasonography showed a large mid-body splenic mass. Contrast enhanced ultrasonography of the liver demonstrated a hypoechoic left lateral lobe nodular mass during the peak and late portal-phases of liver enhancement. Histopathology of the splenic mass and hepatic nodular mass confirmed haemangiosarcoma. The use of ultrasound microbubble contrast media in the diagnosis of hepatic metastasis in the cat has not been previously reported in the cat.

  17. Oxidant/antioxidant status in lambs and sheep with liver and lung cystic echinococcosis diagnosed by ultrasonography and necropsy.

    PubMed

    Sagkan-Ozturk, A; Durgut, R; Ozturk, O H

    2015-03-15

    The aim of this study was to evaluate total antioxidant capacity (TAC), total oxidant status (TOS), and oxidative stress index (OSI) in sheep and lambs with cyctic eccinocoocosis (CE) diagnosed by ultrasonography and necropsy findings. A total of 9 sheep and 17 lambs with CE were used in this study and the findings were compared to those of 6 healthy control sheep. Ultrasonography were used for the diagnosis of CE in sheep and lambs, and necropsy was performed to check the presence of cysts in liver and lungs. Serum TOS and TAC were measured by a novel colorimetric method. The TOS-to-TAC ratios were also calculated as OSI values. Serum biochemical profiles were determined by conventional measurement methods as well. The mean values for TOS, TAC and OSI were significantly (p<0.001) lower in sheep and lambs with CE when compared with those of the control sheep, and they were also significantly lower in lambs with CE in comparison to the mean values obtained in sheep with CE. The levels of serum albumin, total cholesterol, creatinine, and triglycerides in lambs with CE were found out to decrease significantly (p<0.001) when compared with those of both sheep with EC and the control group. There were no significant differences between the groups in terms of other serum parameters. In addition, when clinically and some biochemical values were evaluated, CE was found to be more severe in lambs than in sheep. It was concluded that although common diagnostic cyst detection is performed by postmortem examination, ultrasonography could successfully be used in conjunction with serum biochemical profile detection and serum TOS, TAC and OSI measurements for diagnosis of cysts in liver and lungs of severely infected living sheep and lambs. Serum albumin, total cholesterol, creatinine, total protein and triglycerides might be used as indicators in sheep and particularly in lambs for the diagnosis of CE. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Combined endeavor of Neutrosophic Set and Chan-Vese model to extract accurate liver image from CT scan.

    PubMed

    Siri, Sangeeta K; Latte, Mrityunjaya V

    2017-11-01

    Many different diseases can occur in the liver, including infections such as hepatitis, cirrhosis, cancer and over effect of medication or toxins. The foremost stage for computer-aided diagnosis of liver is the identification of liver region. Liver segmentation algorithms extract liver image from scan images which helps in virtual surgery simulation, speedup the diagnosis, accurate investigation and surgery planning. The existing liver segmentation algorithms try to extort exact liver image from abdominal Computed Tomography (CT) scan images. It is an open problem because of ambiguous boundaries, large variation in intensity distribution, variability of liver geometry from patient to patient and presence of noise. A novel approach is proposed to meet challenges in extracting the exact liver image from abdominal CT scan images. The proposed approach consists of three phases: (1) Pre-processing (2) CT scan image transformation to Neutrosophic Set (NS) and (3) Post-processing. In pre-processing, the noise is removed by median filter. The "new structure" is designed to transform a CT scan image into neutrosophic domain which is expressed using three membership subset: True subset (T), False subset (F) and Indeterminacy subset (I). This transform approximately extracts the liver image structure. In post processing phase, morphological operation is performed on indeterminacy subset (I) and apply Chan-Vese (C-V) model with detection of initial contour within liver without user intervention. This resulted in liver boundary identification with high accuracy. Experiments show that, the proposed method is effective, robust and comparable with existing algorithm for liver segmentation of CT scan images. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population.

    PubMed

    Chan, Wah-Kheong; Nik Mustapha, Nik Raihan; Wong, Grace Lai-Hung; Wong, Vincent Wai-Sun; Mahadeva, Sanjiv

    2017-02-01

    The FibroScan® XL probe reduces failure of liver stiffness measurement (LSM) and unreliable results in obese patients. The objective of this article is to evaluate the accuracy of controlled attenuation parameter (CAP) obtained using the XL probe for the estimation of hepatic steatosis in patients with non-alcoholic fatty liver disease (NAFLD). Adult NAFLD patients with a liver biopsy within six months were included and were examined with the FibroScan® M and XL probes. Histopathological findings were reported according to the Non-Alcoholic Steatohepatitis Clinical Research Network Scoring System. Participants who did not have fatty liver on ultrasonography were recruited as controls. A total of 57 NAFLD patients and 22 controls were included. The mean age of the NAFLD patients and controls was 50.1 ± 10.4 years and 20.2 ± 1.3 years, respectively ( p  = 0.000). The mean body mass index was 30.2 ± 5.0 kg per m 2 and 20.5 ± 2.4 kg per m 2 , respectively ( p  = 0.000). The distribution of steatosis grades were: S0, 29%; S1, 17%; S2, 35%; S3, 19%. The AUROC for estimation of steatosis grade ≥ S1, S2 and S3 was 0.94, 0.80 and 0.69, respectively, using the M probe, and 0.97, 0.81 and 0.67, respectively, using the XL probe. CAP obtained using the XL probe had similar accuracy as the M probe for the estimation of hepatic steatosis in NAFLD patients.

  20. Automatic detection of new tumors and tumor burden evaluation in longitudinal liver CT scan studies.

    PubMed

    Vivanti, R; Szeskin, A; Lev-Cohain, N; Sosna, J; Joskowicz, L

    2017-11-01

    Radiological longitudinal follow-up of liver tumors in CT scans is the standard of care for disease progression assessment and for liver tumor therapy. Finding new tumors in the follow-up scan is essential to determine malignancy, to evaluate the total tumor burden, and to determine treatment efficacy. Since new tumors are typically small, they may be missed by examining radiologists. We describe a new method for the automatic detection and segmentation of new tumors in longitudinal liver CT studies and for liver tumors burden quantification. Its inputs are the baseline and follow-up CT scans, the baseline tumors delineation, and a tumor appearance prior model. Its outputs are the new tumors segmentations in the follow-up scan, the tumor burden quantification in both scans, and the tumor burden change. Our method is the first comprehensive method that is explicitly designed to find new liver tumors. It integrates information from the scans, the baseline known tumors delineations, and a tumor appearance prior model in the form of a global convolutional neural network classifier. Unlike other deep learning-based methods, it does not require large tagged training sets. Our experimental results on 246 tumors, of which 97 were new tumors, from 37 longitudinal liver CT studies with radiologist approved ground-truth segmentations, yields a true positive new tumors detection rate of 86 versus 72% with stand-alone detection, and a tumor burden volume overlap error of 16%. New tumors detection and tumor burden volumetry are important for diagnosis and treatment. Our new method enables a simplified radiologist-friendly workflow that is potentially more accurate and reliable than the existing one by automatically and accurately following known tumors and detecting new tumors in the follow-up scan.

  1. The diagnosis of neonatal pulmonary atelectasis using lung ultrasonography.

    PubMed

    Liu, Jing; Chen, Shui-Wen; Liu, Fang; Li, Qiu-Ping; Kong, Xiang-Yong; Feng, Zhi-Chun

    2015-04-01

    Ultrasonography has been used for the diagnosis of many kinds of lung conditions, but few studies have investigated ultrasound for the diagnosis of neonatal pulmonary atelectasis (NAP). In this study, we evaluated the usefulness of lung ultrasonography for the diagnosis of NPA. From May 2012 to December 2013, 80 neonates with NPA and 50 neonates without lung disease were enrolled in this study. Each lung of every infant was divided into the anterior, lateral, and posterior regions by the anterior and posterior axillary lines. Each region was scanned carefully with the probe perpendicular or parallel to the ribs. The ultrasound findings were confirmed by chest radiograph (CXR) or CT scan. Sixty of the 80 patients with signs of NPA on lung ultrasound also had signs of NPA on CXR (termed focal-type atelectasis), and the other 20 patients had signs of NPA on chest CT scan while there were no abnormal findings on CXR (termed occult lung atelectasis). In patients with NPA, the main ultrasound findings were large areas of lung consolidation with clearly demarcated borders, air bronchograms, pleural line abnormalities, and absence of A-lines, as well as the presence of lung pulse and absence of lung sliding on real-time ultrasound. The sensitivity of lung ultrasonography for the diagnosis of NPA was 100%, whereas the sensitivity of CXR was 75%. Large areas of lung consolidation with clearly demarcated borders were only observed in patients with NPA. Lung ultrasonography is an accurate and reliable method for diagnosing NPA; most importantly, it can find those occult lung atelectasis that could not be detected on CXR. Routine lung ultrasonography is a useful method of diagnosing or excluding NPA in neonates.

  2. Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats.

    PubMed

    Yeager, A E; Mohammed, H

    1992-04-01

    The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.

  3. Grey-scale ultrasonography for monitoring industrial exposure to hepatotoxic agents.

    PubMed

    Taylor, K J; Williams, D M; Smith, P M; Duck, B W

    1975-05-31

    Industrial exposure to several potentially hepatotoxic agents, such as vinyl-chloride monomer may occur, and there is a need for non-vasive, diagnostic techniques to detect and monitor progressive pathological processes in liver or spleen. Grey-scale ultrasonography permits display of detailed anatomy and pathology in the liver, portal veins, and spleen. The combination of fine resolution, non-invasiveness, absence of ionising radiation hazard, and portable equipment makes the technique ideal for screening populations at risk.

  4. Endoscopic ultrasonography in chronic pancreatitis: a comparative prospective study with conventional ultrasonography, computed tomography, and ERCP.

    PubMed

    Buscail, L; Escourrou, J; Moreau, J; Delvaux, M; Louvel, D; Lapeyre, F; Tregant, P; Frexinos, J

    1995-04-01

    The usefulness and accuracy rate of endoscopic ultrasonography (EUS) in the diagnosis of chronic pancreatitis (CP) were prospectively evaluated in 81 patients with suspected pancreatic disease. All underwent EUS, abdominal ultrasonography (AUS), and computed tomography (CT), and endoscopic retrograde cholangiopancreatography (ERCP) was performed in 55 of the cases. The diagnosis of CP was established in 44 patients (CP group) including 24 with a calcified form. No pancreatic disease was observed in 18 patients (control group), and 19 patients had a pancreatic tumor. In the CP group AUS was less accurate than EUS in visualizing the pancreas, performances of CT scan being identical to EUS in this respect. A good correlation was observed between EUS and ERCP for visualization and measurement of the Wirsung duct. The most significant changes observed by EUS in the CP group were dilatation of the main pancreatic duct, heterogeneous echogenicity of the pancreatic parenchyma, and cysts < 20 mm in size even in noncalcified CP or with normal pancreatograms. Sensitivity of EUS for diagnosis of CP was 88% (AUS, 58%; ERCP, 74%; CT scan, 75%), the specificity being 100% for ERCP and EUS, 95% for CT scan, and 75% for AUS. The good performances of EUS allow early diagnosis of CP in symptomatic patients since heterogeneous echogenicity of the pancreatic parenchyma seems to be almost specifically associated with the disease.

  5. Superior staging of liver tumors with laparoscopy and laparoscopic ultrasound.

    PubMed Central

    John, T G; Greig, J D; Crosbie, J L; Miles, W F; Garden, O J

    1994-01-01

    OBJECTIVE. The authors describe the technique of staging laparoscopy with laparoscopic contact ultrasonography in the preoperative assessment of patients with liver tumors, and assess its impact on the selection of patients for hepatic resection with curative intent. SUMMARY BACKGROUND DATA. Laparoscopy may be useful in the selection of patients with a variety of intra-abdominal malignancies for operative intervention. Laparoscopic ultrasonography is a new technique that combines the principles of high resolution intraoperative contact ultrasound with those of the laparoscopic examination, and thus, allows the laparoscopist to perform detailed assessment of the liver. METHODS. This study analyzes a cohort of 50 consecutive patients who were diagnosed as having potentially resectable liver tumors, and in whom staging laparoscopy was successfully undertaken. Laparoscopic ultrasonography was performed in 43 patients, and the impact of the ensuing findings on the decision to proceed to operative assessment of resectability is examined. The resectability rate in those patients assessed laparoscopically and subsequently submitted to laparotomy is compared with a preceding group of patients in whom no laparoscopic assessment was performed. RESULTS. Laparoscopy demonstrated factors precluding curative resection in 23 patients (46%). Laparoscopic ultrasonography identified liver tumors not visible during laparoscopy in 14 patients (33%), and provided staging information in addition to that derived from laparoscopy alone in 18/43 patients (42%). The resectability rate was significantly higher among those patients undergoing laparoscopic staging (93%) compared with those in whom operative assessment was undertaken without laparoscopy (58%). CONCLUSIONS. Staging laparoscopy with laparoscopic ultrasonography optimizes patient selection for liver resection with curative intent. Images Figure 1. Figure 2. PMID:7986136

  6. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography.

    PubMed

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the usefulness of OXR in the diagnosis of the occult pneumothorax and to compare OXR with ultrasonography. All consecutive blunt chest trauma patients with clinically suspected pneumothorax on arrival at the emergency department were prospectively included at our tertiary-care center. The patients underwent OXR and ultrasonography, and underwent computed tomography scans as the gold standard. Occult pneumothorax size on computed tomography was classified as minuscule, anterior, or anterolateral. One hundred and fifty-nine patients were enrolled. Of the 70 occult pneumothoraces found in the 318 thoraces, 19 were minuscule, 32 were anterior, and 19 were anterolateral. The sensitivity and specificity of OXR for detecting occult pneumothorax was 61.4 % and 99.2 %, respectively. The sensitivity and specificity of lung ultrasonography was 62.9 % and 98.8 %, respectively. Among 27 occult pneumothoraces that could not be detected by OXR, 16 were minuscule and 21 could be conservatively managed without thoracostomy. OXR appears to be as good method as lung ultrasonography in the detection of large occult pneumothorax. In trauma patients who are difficult to transfer to computed tomography scan, OXR may be effective at detecting occult pneumothorax with a risk of progression.

  7. Value of gallbladder B-scan ultrasonography.

    PubMed

    Tabrisky, J; Lindstrom, R R; Herman, M W; Castagna, J; Sarti, D

    1975-05-01

    The gallbladder B-scans of 20 patients who had subsequent surgery were separated into three categories based upon certain sonographic criteria. Our data, in this limited series, revealed gallbladder pathology in each patient who had any one or combination of the following scan characteristics: (1) internal echos, (2) irregular wall, or (3) absence of recognizable gallbladder sonolucency. The category which demonstrated a normal sonographic gallbladder, namely a smooth wall and no internal echos, contained a number of false negatives which proved to have either small stone cholelithiasis or extraphepatic ductal obstruction. Within the described limitations, the B-scan can be a valuable test in confirming the significance of a radiographically nonvisualized gallbladder or in detecting a biliary tract lesion in a patient with a disease entity that precludes radiographic visualization by conventional techniques.

  8. Ultrasonography in diagnosing chronic pancreatitis: New aspects

    PubMed Central

    Dimcevski, Georg; Erchinger, Friedemann G; Havre, Roald; Gilja, Odd Helge

    2013-01-01

    The course and outcome is poor for most patients with pancreatic diseases. Advances in pancreatic imaging are important in the detection of pancreatic diseases at early stages. Ultrasonography as a diagnostic tool has made, virtually speaking a technical revolution in medical imaging in the new millennium. It has not only become the preferred method for first line imaging, but also, increasingly to clarify the interpretation of other imaging modalities to obtain efficient clinical decision. We review ultrasonography modalities, focusing on advanced pancreatic imaging and its potential to substantially improve diagnosis of pancreatic diseases at earlier stages. In the first section, we describe scanning techniques and examination protocols. Their consequences for image quality and the ability to obtain complete and detailed visualization of the pancreas are discussed. In the second section we outline ultrasonographic characteristics of pancreatic diseases with emphasis on chronic pancreatitis. Finally, new developments in ultrasonography of the pancreas such as contrast enhanced ultrasound and elastography are enlightened. PMID:24259955

  9. Carcinoma of the pancreatic head and periampullary region. Tumor staging with laparoscopy and laparoscopic ultrasonography.

    PubMed Central

    John, T G; Greig, J D; Carter, D C; Garden, O J

    1995-01-01

    OBJECTIVE: The authors performed a prospective evaluation of staging laparoscopy with laparoscopic ultrasonography in predicting surgical resectability in patients with carcinomas of the pancreatic head and periampullary region. SUMMARY BACKGROUND DATA: Pancreatic resection with curative intent is possible in a select minority of patients who have carcinomas of the pancreatic head and periampullary region. Patient selection is important to plan appropriate therapy and avoid unnecessary laparotomy in patients with unresectable disease. Laparoscopic ultrasonography is a novel technique that combines the proven benefits of staging laparoscopy with high resolution intraoperative ultrasound of the liver and pancreas, but which has yet to be evaluated critically in the staging of pancreatic malignancy. METHODS: A cohort of 40 consecutive patients referred to a tertiary referral center and with a diagnosis of potentially resectable pancreatic or periampullary cancer underwent staging laparoscopy with laparoscopic ultrasonography. The diagnostic accuracy of staging laparoscopy alone and in conjunction with laparoscopic ultrasonography was evaluated in predicting tumor resectability (absence of peritoneal or liver metastases; absence of malignant regional lymphadenopathy; tumor confined to pancreatic head or periampullary region). RESULTS: "Occult" metastatic lesions were demonstrated by staging laparoscopy in 14 patients (35%). Laparoscopic ultrasonography demonstrated factors confirming unresectable tumor in 23 patients (59%), provided staging information in addition to that of laparoscopy alone in 20 patients (53%), and changed the decision regarding tumor resectability in 10 patients (25%). Staging laparoscopy with laparoscopic ultrasonography was more specific and accurate in predicting tumor resectability than laparoscopy alone (88% and 89% versus 50% and 65%, respectively). CONCLUSIONS: Staging laparoscopy is indispensable in the detection of "occult" intra

  10. Functional liver image guided hepatic therapy (FLIGHT) with hepatobiliary iminodiacetic acid (HIDA) scans.

    PubMed

    Long, David E; Tann, Mark; Huang, Ke Colin; Bartlett, Gregory; Galle, James O; Furukawa, Yukie; Maluccio, Mary; Cox, John A; Kong, Feng-Ming Spring; Ellsworth, Susannah G

    2018-05-01

    Hepatobiliary iminodiacetic acid (HIDA) scans provide global and regional assessments of liver function that can serve as a road map for functional avoidance in stereotactic body radiation therapy (SBRT) planning. Functional liver image guided hepatic therapy (FLIGHT), an innovative planning technique, is described and compared with standard planning using functional dose-volume histograms. Thresholds predicting for decompensation during follow up are evaluated. We studied 17 patients who underwent HIDA scans before SBRT. All SBRT cases were replanned using FLIGHT. The following dosimetric endpoints were compared for FLIGHT versus standard SBRT planning: functional residual capacity <15 Gy (FRC 15 HIDA), mean liver dose (MLD), equivalent uniform dose (EUD), and functional EUD (FEUD). Receiver operating characteristics curves were used to evaluate whether baseline HIDA values, standard cirrhosis scoring, and/or dosimetric data predicted clinical decompensation. Compared with standard planning, FLIGHT significantly improved FRC 15 HIDA (mean improvement: 5.3%) as well as MLD, EUD, and FEUD (P < .05). Considerable interindividual variations in the extent of benefit were noted. Decompensation during follow-up was associated with baseline global HIDA <2.915%/min/m 2 , FRC 15 HIDA <2.11%/min/m 2 , and MELD ≥11 (P < .05). FLIGHT with HIDA-based parameters may complement blood chemistry-based assessments of liver function and facilitate individualized, adaptive liver SBRT planning. Copyright © 2018. Published by Elsevier Inc.

  11. A fully automatic end-to-end method for content-based image retrieval of CT scans with similar liver lesion annotations.

    PubMed

    Spanier, A B; Caplan, N; Sosna, J; Acar, B; Joskowicz, L

    2018-01-01

    The goal of medical content-based image retrieval (M-CBIR) is to assist radiologists in the decision-making process by retrieving medical cases similar to a given image. One of the key interests of radiologists is lesions and their annotations, since the patient treatment depends on the lesion diagnosis. Therefore, a key feature of M-CBIR systems is the retrieval of scans with the most similar lesion annotations. To be of value, M-CBIR systems should be fully automatic to handle large case databases. We present a fully automatic end-to-end method for the retrieval of CT scans with similar liver lesion annotations. The input is a database of abdominal CT scans labeled with liver lesions, a query CT scan, and optionally one radiologist-specified lesion annotation of interest. The output is an ordered list of the database CT scans with the most similar liver lesion annotations. The method starts by automatically segmenting the liver in the scan. It then extracts a histogram-based features vector from the segmented region, learns the features' relative importance, and ranks the database scans according to the relative importance measure. The main advantages of our method are that it fully automates the end-to-end querying process, that it uses simple and efficient techniques that are scalable to large datasets, and that it produces quality retrieval results using an unannotated CT scan. Our experimental results on 9 CT queries on a dataset of 41 volumetric CT scans from the 2014 Image CLEF Liver Annotation Task yield an average retrieval accuracy (Normalized Discounted Cumulative Gain index) of 0.77 and 0.84 without/with annotation, respectively. Fully automatic end-to-end retrieval of similar cases based on image information alone, rather that on disease diagnosis, may help radiologists to better diagnose liver lesions.

  12. Ultrasonography of the liver, spleen, and urinary tract of the cheetah (Acinonyx jubatus).

    PubMed

    Carstens, Ann; Kirberger, Robert M; Spotswood, Tim; Wagner, Wencke M; Grimbeek, Richard J

    2006-01-01

    Diseases of the abdomen of the cheetah (Acinonyx jubatus) include those affecting the liver, spleen, and urinary tract. The most common diseases of captive-bred cheetah are gastritis, gastric ulceration, glomerulosclerosis, and hepatic veno-occlusive disease, and are the most frequent causes of mortality in these animals. The purpose of this study was to describe the ultrasonographic anatomy of the normal liver, spleen, kidney, and urinary bladder of the anesthetized captive-bred cheetah. Twenty-one cheetahs were examined. Eight of the 21 animals had subclinical evidence of either gastritis or chronic renal disease. The ultrasonographic appearances of the liver, gall bladder, common bile duct, and spleen were evaluated and various measurements made. Statistical analyses of the measurements were performed on all the healthy and subclinically ill animals taking sex, age, mass, and anesthetic protocol into account. There were no significant differences in any parameters between the healthy and subclinically ill animals (P > 0.25) and data were combined for statistical analyses. The mean mass was 41.1kg ( +/- 8.8) and the mean age was 5.0 years (+/- 2.2). The mean thickness of the liver medial to the gall bladder was 67.0 mm (+/- 14.8) and the liver was within the left costal arch in 75% of animals, extended caudal to the right costal arch in 50% of animals for an average of 30 mm, and extended caudal to the sternum in 63% of animals for an average of 32.5 mm. The maximum mean hepatic vein diameter at the entrance to the caudal vena cava was 8.6 +/- 2.8 mm; the mean diameters of the portal vein at the hilus and that of the caudal vena cava as it entered the liver were 7.5 +/- 1.6 and 9.9 +/- 4.1 mm, respectively. The mean diameter of the caudal vena cava was significantly affected by the type of anesthetic used (P < 0.10). The mass of the animals was significant in explaining the variance in maximum portal vein diameters (P < 0.10). The mean maximum velocity of the

  13. A comparative study of endoscopic ultrasonography versus endoscopic retrograde cholangiopancreatography in children with chronic liver disease.

    PubMed

    El-Karaksy, Hanaa M; El-Koofy, Nehal M; Okasha, Hussein; Kamal, Naglaa M; Naga, Mazen

    2008-09-01

    Endoscopic ultrasonography (EUS) is a less invasive modality and may be equal or superior to endoscopic retrograde cholangiopancreatography (ERCP) in visualizing the biliary tree. Its role and feasibility in children need to be accurately defined. This study aimed at evaluation of EUS in assessment of children with chronic liver disease (CLD) in comparison with ERCP. The present study was carried out between September 2004 and February 2006 on 40 children suffering from CLD. Patients were selected from the Pediatric Hepatology Unit, Cairo University Children's Hospital, Egypt. They were included if they had: sonographic (n = 8) or histopathological evidence of biliary pathology (n = 2); autoimmune hepatitis with high gamma glutammyl transpeptidase (GGT) levels and/or not responding to immunosuppressive therapy (n = 15); cryptogenic CLD (n = 13); neonatal cholestasis with relapsing or persistent course (n = 2). They all underwent EUS and ERCP. Three of six cases with intrahepatic biliary radicle dilatation had Caroli's disease by EUS and ERCP; and the other 3 had sclerosing cholangitis. EUS was equal to ERCP in diagnosis of biliary pathology. However, one false positive case was described to have dilatation and tortuosity of the pancreatic duct by EUS as compared to ERCP. EUS could detect early pancreatitis in 5 cases. One case with cryptogenic liver disease proved to have sclerosing cholangitis by both EUS and ERCP. EUS is an important diagnostic tool for biliary pathology and pancreatitis in children with pancreatico-biliary pathology. ERCP should be reserved for therapeutic purposes.

  14. Diagnostic accuracy and prognostic significance of blood fibrosis tests and liver stiffness measurement by FibroScan in non-alcoholic fatty liver disease.

    PubMed

    Boursier, Jérôme; Vergniol, Julien; Guillet, Anne; Hiriart, Jean-Baptiste; Lannes, Adrien; Le Bail, Brigitte; Michalak, Sophie; Chermak, Faiza; Bertrais, Sandrine; Foucher, Juliette; Oberti, Frédéric; Charbonnier, Maude; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Calès, Paul; de Lédinghen, Victor

    2016-09-01

    NAFLD is highly prevalent but only a small subset of patients develop advanced liver fibrosis with impaired liver-related prognosis. We aimed to compare blood fibrosis tests and liver stiffness measurement (LSM) by FibroScan for the diagnosis of liver fibrosis and the evaluation of prognosis in NAFLD. Diagnostic accuracy was evaluated in a cross-sectional study including 452 NAFLD patients with liver biopsy (NASH-CRN fibrosis stage), LSM, and eight blood fibrosis tests (BARD, NAFLD fibrosis score, FibroMeter(NAFLD), aspartate aminotransferase to platelet ratio index (APRI), FIB4, FibroTest, Hepascore, FibroMeter(V2G)). Prognostic accuracy was evaluated in a longitudinal study including 360 NAFLD patients. LSM and FibroMeter(V2G) were the two best-performing tests in the cross-sectional study: AUROCs for advanced fibrosis (F3/4) were, respectively, 0.831±0.019 and 0.817±0.020 (p⩽0.041 vs. other tests); rates of patients with ⩾90% negative/positive predictive values for F3/4 were 56.4% and 46.7% (p<0.001 vs. other tests); Obuchowski indexes were 0.834±0.014 and 0.798±0.016 (p⩽0.036 vs. other tests). Two fibrosis classifications were developed to precisely estimate the histological fibrosis stage from LSM or FibroMeter(V2G) results without liver biopsy (diagnostic accuracy, respectively: 80.8% vs. 77.4%, p=0.190). Kaplan-Meier curves in the longitudinal study showed that both classifications categorised NAFLD patients into subgroups with significantly different prognoses (p<0.001): the higher was the class of the fibrosis classification, the worse was the prognosis. LSM and FibroMeter(V2G) were the most accurate of nine evaluated tests for the non-invasive diagnosis of liver fibrosis in NAFLD. LSM and FibroMeter(V2G) fibrosis classifications help physicians estimate both fibrosis stage and patient prognosis in clinical practice. The amount of liver fibrosis is the main determinant of the liver-related prognosis in patients with non-alcoholic fatty liver

  15. Evaluation of hepatic function with (99m)Tc-galactosylated serum albumin scintigraphy in patients with malaria: comparison with (99m)Tc-colloid scintigraphy and liver ultrasonography.

    PubMed

    Lee, Sang-Woo; Lee, Jaetae; Lee, Deog-Young; Chun, Kyung-Ah; Ahn, Byeong-Cheol; Kang, Young-Mo; Lee, Kyubo

    2007-02-01

    Malarial parasites injected by the mosquito rapidly target hepatocytes, and hepatomegaly is commonly observed during the progress of the disease in malaria patients. To evaluate the degree of hepatic damage and functional status of hepatocytes in malaria patients, we performed liver scintigraphy using (99m)Tc-galactosylated serum albumin (GSA) prospectively and the findings were compared with those of (99m)Tc-colloid scintigraphy, ultrasonography and clinical results in the same subject. Eight malaria patients (all male, mean age 22 years) confirmed to be infected with Plasmodium vivax underwent (99m)Tc-GSA liver scintigraphy, followed by liver ultrasonography and (99m)Tc-colloid scintigraphy using phytate within 3 days. For hepatocyte scintigraphy, anterior images of cardiac blood-pool and liver were continuously acquired for 30 min after injection of 185 MBq (99m)Tc-GSA (3 mg). In addition to visual interpretation of the images, quantitative measurement of hepatic function was performed with several functional parameters, such as hepatic uptake index (LHL15), blood clearance index (HH15) and modified receptor index (LHL/HH) calculated from the radioactivity of the liver and heart. (99m)Tc-colloid images were assessed and graded visually. Severity of hepatic dysfunction or reticuloendothelial system activation was classified as normal, mild, moderate and severe on GSA or colloid images. Hepatomegaly was observed in five and splenomegaly in seven of the eight patients. Serum levels of transaminase and alkaline phosphatase were mildly elevated in two. Visual assessment of GSA scintigraphy revealed normal findings in all subjects, except for mild increases in size. The mean values of LHL15, HH15 and LHL/HH were 0.928+/-0.014, 0.537+/-0.031 and 1.732+/-0.106, respectively. They were graded as normal in five, and near-normal to mild dysfunction in three subjects. In contrast, (99m)Tc-colloid scintigraphy revealed abnormal findings in all of the subjects, and graded as

  16. WE-E-BRB-02: Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, L.

    Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed.more » Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of

  17. Fundamentals of diagnostic ultrasonography.

    PubMed

    Noce, J P

    1990-01-01

    Diagnostic ultrasonography uses acoustical waves in the frequency range of 1 to 20 MHz. These waves obey Snell's law of reflection and refraction, which are rules ordinary to wave behavior. In ultrasound, the analogy to momentum is acoustic impedance. The acoustic impedance, Z, is equal to the density, p, times velocity, v. The ultrasound transducer converts electrical energy into ultrasound energy and vice versa. The transducer usually consists of a piezoelectric crystal composed of such ceramic materials as barium titanate, lead titanate, zirconate, or lead metaniobate. Five basic ultrasonic scanning modes play the major roles in clinical applications. A-mode, or amplitude-mode, scanning measures the tissue discontinuity along the scan axis. B-mode scanning produces a two-dimensional image of the tissue under study by combining A-mode signals from various directions through mechanical transducer scanning. M-mode, or time motion scanning, is an extension of the A-mode approach in which a single stationary transducer is used. The depth of the echo is displayed on the vertical axis; the brightness of the oscilloscope display is modulated by the echo amplitude. Real-time scanning, or rapid B-scanning, techniques provide continuous data acquisition at a rate sufficient to give the impression of the instantaneous motion of moving structures. Doppler scanning relies on the presence of motion. The Doppler effect occurs when there is relative motion between the source of sound and the receiver of the sound, causing a change in the detected frequency of the sound source.

  18. Laparoscopic enucleation of liver tumors. Corkscrew technique revisited.

    PubMed

    Makdissi, Fabio F; Surjan, Rodrigo C T; Machado, Marcel Autran C

    2009-03-01

    Enucleation of small lesions located near the hepatic surface can be achieved with low morbidity and mortality. This article describes a simple laparoscopic technique for enucleation of liver tumors. After inspection and intraoperative ultrasonography, Glisson's capsule is marked with eletrocautery 2 cm away from the tumor margin. Ultrasonography is used to ascertain surgical margin right before liver transection. Hemihepatic ischemia is applied and marked area is anchored by stitches. The suture is held together by metallic clips and upward traction is performed, facilitating the transection of the parenchyma and correct identification of vascular and biliary structures. This technique has been successfully employed in six consecutive patients. There were four men and two women, mean age 50.3 years. Four patients underwent liver resection for malignant disease and two for benign liver neoplasm. Pathologic surgical margins were free in all cases and mean hospital stay was 2 days. No postoperative mortality was observed. This technique may facilitate laparoscopic nonanatomical liver resection and reduce risk of positive surgical margins. It is also useful in combination with anatomical laparoscopic liver resections such as right or left hemihepatectomies in patients with bilateral liver tumors as occurred in one of our patients.

  19. Creation and Validation of a Simulator for Neonatal Brain Ultrasonography: A Pilot Study.

    PubMed

    Tsai, Andy; Barnewolt, Carol E; Prahbu, Sanjay P; Yonekura, Reimi; Hosmer, Andrew; Schulz, Noah E; Weinstock, Peter H

    2017-01-01

    Historically, skills training in performing brain ultrasonography has been limited to hours of scanning infants for lack of adequate synthetic models or alternatives. The aim of this study was to create a simulator and determine its utility as an educational tool in teaching the skills that can be used in performing brain ultrasonography on infants. A brain ultrasonography simulator was created using a combination of multi-modality imaging, three-dimensional printing, material and acoustic engineering, and sculpting and molding. Radiology residents participated prior to their pediatric rotation. The study included (1) an initial questionnaire and resident creation of three coronal images using the simulator; (2) brain ultrasonography lecture; (3) hands-on simulator practice; and (4) a follow-up questionnaire and re-creation of the same three coronal images on the simulator. A blinded radiologist scored the quality of the pre- and post-training images using metrics including symmetry of the images and inclusion of predetermined landmarks. Wilcoxon rank-sum test was used to compare pre- and post-training questionnaire rankings and image quality scores. Ten residents participated in the study. Analysis of pre- and post-training rankings showed improvements in technical knowledge and confidence, and reduction in anxiety in performing brain ultrasonography. Objective measures of image quality likewise improved. Mean reported value score for simulator training was high across participants who reported perceived improvements in scanning skills and enjoyment from simulator use, with interest in additional practice on the simulator and recommendations for its use. This pilot study supports the use of a simulator in teaching radiology residents the skills that can be used to perform brain ultrasonography. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    PubMed

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  1. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.

    PubMed

    Vafaei, Ali; Hatamabadi, Hamid Reza; Heidary, Kamran; Alimohammadi, Hosein; Tarbiyat, Mohammad

    2016-01-01

    Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT) scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67), were enrolled (77.6% male). Chest CT scan showed pulmonary contusion in 48 (31.6%) patients, hemothorax in 29 (19.1%), and pneumothorax in 55 (36.2%) cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96), 0.86 (95% CI: 0.78‒0.94), and 0.80 (95% CI: 0.736‒0.88), respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87) for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86) for hemothorax, and 0.58 (95% CI: 0.5‒0.67) for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02) and pulmonary contusion (p < 0.001). However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08). The results of the present study showed that ultrasonography is preferable to radiography in the initial evaluation of patients with traumatic injuries to the

  2. Radioisotope scanning of brain, liver, lung and bone with a note on tumour localizing agents

    PubMed Central

    Lavender, J. P.

    1973-01-01

    Radioisotopic scanning of brain, liver, lungs and the skeleton is briefly reviewed with a survey of recent developments of clinical significance. In brain scanning neoplasm detection rates of greater than 90% are claimed. The true figure is probably 70-80%. Autopsy data shows a number of false negatives, particularly with vascular lesions. Attempts to make scanning more specific in differentiating neoplasm from vascular lesions by rapid sequence blood flow studies are reviewed. In liver scanning by means of colloids again high success rate is claimed but small metastases are frequently missed and the false negative scan rate is probably quite high. Lung scanning still has its main place in investigating pulmonary embolic disease. Ventilation studies using Xenon 133 are useful, particularly combined with perfusion studies. The various radiopharmaceuticals for use in bone scanning are reviewed. The appearance of technetium labelled phosphate compounds will probably allow much wider use of total skeletal scanning. Research into tumour localizing agents continues, the most recent and interesting being Gallium citrate and labelled bleomycin. Neither agent is predictable however although Gallium may have a place in Hodgkins disease and bronchogenic neoplasm and both may have a place in the detection of cerebral tumours. ImagesFig. 1Fig. 2Fig. 3p452-bFig. 3bFig. 4Fig. 5Fig. 5bFig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 12c & 12dFig. 13Fig. 13 b,c,dFig. 14Fig. 14bFig. 15Fig. 15bFig. 16Fig. 17Fig. 18 PMID:4602127

  3. Ultrasonography of uterine leiomyomas.

    PubMed

    Woźniak, Andrzej; Woźniak, Sławomir

    2017-12-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan - TVS) or transabdominally (transabdominal scan - TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus.

  4. Ultrasonography of uterine leiomyomas

    PubMed Central

    Woźniak, Andrzej

    2017-01-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan – TVS) or transabdominally (transabdominal scan – TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus. PMID:29483851

  5. Correlation of Body Mass Index and Serum Parameters With Ultrasonographic Grade of Fatty Change in Non-alcoholic Fatty Liver Disease

    PubMed Central

    Abangah, Ghobad; Yousefi, Atefeh; Asadollahi, Rouhangiz; Veisani, Yousef; Rahimifar, Paria; Alizadeh, Sajjad

    2014-01-01

    Background: Non-alcoholic fatty liver disease (NAFLD) is a common liver disease in the western population and expanding disease in the world. Pathological changes in fatty liver are like alcohol liver damage, which can lead to end-stage liver disease. The prevalence of NAFLD in obese or overweight people is higher than general population, and it seems that people with high Body Mass Index (BMI) or abnormality in some laboratory tests are more susceptible for severe fatty liver and high grade of NAFLD in ultrasonography (U.S). Objectives: This study aimed to evaluate the correlation of BMI and laboratory tests with NAFLD in ultrasonography. Materials and Methods: During a multi-step process, we selected two-hundred and thirteen cases from four hundred and eighteen patients with NAFLD. Laboratory tests performed included: ALT, AST, FBS, Triglyceride and cholesterol levels, hepatitis B surface antigen, hepatitis C antibody, ceruloplasmin, serum iron, TIBC, transferrin saturation, ferritin, AMA, ANA, ANTI LKM1, serum protein electrophoresis, TSH, anti TTG (IgA). BMI and ultrasonography for 213 patients were performed, and then data was analyzed. These parameters and grades of ultrasonography were compared with the values obtained using one way ANOVA. An ordinal logistic regression model was used to estimate the probability of ultrasonography grade. The Statistical Package for the Social Science program (SPSS, version 16.0) was used for data analysis. Results: Two-hundred and thirteen cases including 140 male and 73 female, were studied. In general, 72.3% of patients were overweight and obese. Post-hoc tests showed that only BMI (P < 0.001) and TG (P < 0.011) among variables had statistically significant associations with ultrasonography grade (USG), and ordinal logistic regression model showed that BMI and AST were the best predictors. Discussion: Our results suggest that in patients with NAFLD, BMI and TG are most effective factors in severity of fatty liver disease

  6. Correlation of Body Mass Index and Serum Parameters With Ultrasonographic Grade of Fatty Change in Non-alcoholic Fatty Liver Disease.

    PubMed

    Abangah, Ghobad; Yousefi, Atefeh; Asadollahi, Rouhangiz; Veisani, Yousef; Rahimifar, Paria; Alizadeh, Sajjad

    2014-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a common liver disease in the western population and expanding disease in the world. Pathological changes in fatty liver are like alcohol liver damage, which can lead to end-stage liver disease. The prevalence of NAFLD in obese or overweight people is higher than general population, and it seems that people with high Body Mass Index (BMI) or abnormality in some laboratory tests are more susceptible for severe fatty liver and high grade of NAFLD in ultrasonography (U.S). This study aimed to evaluate the correlation of BMI and laboratory tests with NAFLD in ultrasonography. During a multi-step process, we selected two-hundred and thirteen cases from four hundred and eighteen patients with NAFLD. Laboratory tests performed included: ALT, AST, FBS, Triglyceride and cholesterol levels, hepatitis B surface antigen, hepatitis C antibody, ceruloplasmin, serum iron, TIBC, transferrin saturation, ferritin, AMA, ANA, ANTI LKM1, serum protein electrophoresis, TSH, anti TTG (IgA). BMI and ultrasonography for 213 patients were performed, and then data was analyzed. These parameters and grades of ultrasonography were compared with the values obtained using one way ANOVA. An ordinal logistic regression model was used to estimate the probability of ultrasonography grade. The Statistical Package for the Social Science program (SPSS, version 16.0) was used for data analysis. Two-hundred and thirteen cases including 140 male and 73 female, were studied. In general, 72.3% of patients were overweight and obese. Post-hoc tests showed that only BMI (P < 0.001) and TG (P < 0.011) among variables had statistically significant associations with ultrasonography grade (USG), and ordinal logistic regression model showed that BMI and AST were the best predictors. Our results suggest that in patients with NAFLD, BMI and TG are most effective factors in severity of fatty liver disease and ultrasonography grade (USG). On the other hand, BMI as a

  7. Computer-aided diagnosis of focal liver lesions by use of physicians' subjective classification of echogenic patterns in baseline and contrast-enhanced ultrasonography.

    PubMed

    Sugimoto, Katsutoshi; Shiraishi, Junji; Moriyasu, Fuminori; Doi, Kunio

    2009-04-01

    To develop a computer-aided diagnostic (CAD) scheme for classifying focal liver lesions (FLLs) by use of physicians' subjective classification of echogenic patterns of FLLs on baseline and contrast-enhanced ultrasonography (US). A total of 137 hepatic lesions in 137 patients were evaluated with B-mode and NC100100 (Sonazoid)-enhanced pulse-inversion US; lesions included 74 hepatocellular carcinomas (HCCs) (23: well-differentiated, 36: moderately differentiated, 15: poorly differentiated HCCs), 33 liver metastases, and 30 liver hemangiomas. Three physicians evaluated single images at B-mode and arterial phases with a cine mode. Physicians were asked to classify each lesion into one of eight B-mode and one of eight enhancement patterns, but did not make a diagnosis. To classify five types of FLLs, we employed a decision tree model with four decision nodes and four artificial neural networks (ANNs). The results of the physicians' pattern classifications were used successively for four different ANNs in making decisions at each of the decision nodes in the decision tree model. The classification accuracies for the 137 FLLs were 84.8% for metastasis, 93.3% for hemangioma, and 98.6% for all HCCs. In addition, the classification accuracies for histological differentiation types of HCCs were 65.2% for well-differentiated HCC, 41.7% for moderately differentiated HCC, and 80.0% for poorly differentiated HCC. This CAD scheme has the potential to improve the diagnostic accuracy of liver lesions. However, the accuracy in the histologic differential diagnosis of HCC based on baseline and contrast-enhanced US is still limited.

  8. Liver disease

    MedlinePlus

    ... Coccidioidomycosis Delta agent (hepatitis D) Drug-induced cholestasis Fatty liver disease Hemochromatosis Hepatitis A Hepatitis B Hepatitis C ... abscess Reye syndrome Sclerosing cholangitis Wilson disease Images Fatty liver, CT scan Liver with disproportional fattening, CT scan ...

  9. Automated measurement of uptake in cerebellum, liver, and aortic arch in full-body FDG PET/CT scans.

    PubMed

    Bauer, Christian; Sun, Shanhui; Sun, Wenqing; Otis, Justin; Wallace, Audrey; Smith, Brian J; Sunderland, John J; Graham, Michael M; Sonka, Milan; Buatti, John M; Beichel, Reinhard R

    2012-06-01

    The purpose of this work was to develop and validate fully automated methods for uptake measurement of cerebellum, liver, and aortic arch in full-body PET/CT scans. Such measurements are of interest in the context of uptake normalization for quantitative assessment of metabolic activity and/or automated image quality control. Cerebellum, liver, and aortic arch regions were segmented with different automated approaches. Cerebella were segmented in PET volumes by means of a robust active shape model (ASM) based method. For liver segmentation, a largest possible hyperellipsoid was fitted to the liver in PET scans. The aortic arch was first segmented in CT images of a PET/CT scan by a tubular structure analysis approach, and the segmented result was then mapped to the corresponding PET scan. For each of the segmented structures, the average standardized uptake value (SUV) was calculated. To generate an independent reference standard for method validation, expert image analysts were asked to segment several cross sections of each of the three structures in 134 F-18 fluorodeoxyglucose (FDG) PET/CT scans. For each case, the true average SUV was estimated by utilizing statistical models and served as the independent reference standard. For automated aorta and liver SUV measurements, no statistically significant scale or shift differences were observed between automated results and the independent standard. In the case of the cerebellum, the scale and shift were not significantly different, if measured in the same cross sections that were utilized for generating the reference. In contrast, automated results were scaled 5% lower on average although not shifted, if FDG uptake was calculated from the whole segmented cerebellum volume. The estimated reduction in total SUV measurement error ranged between 54.7% and 99.2%, and the reduction was found to be statistically significant for cerebellum and aortic arch. With the proposed methods, the authors have demonstrated that

  10. B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.

    PubMed

    D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J

    2016-09-01

    Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. The utility of repeat sestamibi scans in patients with primary hyperparathyroidism after an initial negative scan.

    PubMed

    Krishnamurthy, Vikram D; Sound, Sara; Okoh, Alexis K; Yazici, Pinar; Yigitbas, Hakan; Neumann, Donald; Doshi, Krupa; Berber, Eren

    2017-06-01

    We analyzed the utility of repeated sestambi scans in patients with primary hyperparathyroidism and its effects on operative referral. We carried out a retrospective review of patients with primary hyperparathyroidism who underwent repeated sestambi scans exclusively within our health system between 1996-2015. Patient demographic, presentation, laboratory, imaging, operative, and pathologic data were reviewed. Univariate analysis with JMP Pro v12 was used to identify factors associated with conversion from an initial negative to a subsequent positive scan. After exclusion criteria (including reoperations), we identified 49 patients in whom 59% (n = 29) of subsequent scans remained negative and 41% (n = 20) converted to positive. Factors associated with an initial negative to a subsequent positive scan included classic presentation and second scans with iodine subtraction (P = .04). Nonsurgeons were less likely to order an iodine-subtraction scan (P < .05). Fewer patients with negative imaging were referred to surgery (33% vs 100%, P = .005), and median time to operation after the first negative scan was 25 months (range 1.4-119). Surgeon-performed ultrasonography had greater sensitivity and positive predictive value than repeated sestamibi scans. Negative sestambi scans decreased and delayed operative referral. Consequently, we identified several process improvement initiatives, including education regarding superior institutional imaging. Combining all findings, we created an algorithm for evaluating patients with primary hyperparathyroidism after initially negative sestamibi scans, which incorporates surgeon-performed ultrasonography. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Drug-induced liver injury caused by iodine-131

    PubMed Central

    Kim, Chei Won; Park, Ji Sun; Oh, Se Hwan; Park, Jae-Hyung; Shim, Hyun-Ik; Yoon, Jae Woong; Park, Jin Seok; Hong, Seong Bin; Kim, Jun Mi; Le, Trong Binh; Lee, Jin Woo

    2016-01-01

    Iodine-131 is a radioisotope that is routinely used for the treatment of differentiated thyroid cancer after total or near-total thyroidectomy. However, there is some evidence that iodine-131 can induce liver injury . Here we report a rare case of drug-induced liver injury (DILI) caused by iodine-131 in a patient with regional lymph node metastasis after total thyroidectomy. A 47-year-old woman was admitted with elevated liver enzymes and symptoms of general weakness and nausea. Ten weeks earlier she had undergone a total thyroidectomy for papillary thyroid carcinoma and had subsequently been prescribed levothyroxine to reduce the level of thyroid-stimulating hormone. Eight weeks after surgery she underwent iodine-131 ablative therapy at a dose of 100 millicuries, and subsequently presented with acute hepatitis after 10 days. To rule out all possible causative factors, abdominal ultrasonography, endoscopic ultrasonography (on the biliary tree and gall bladder), and a liver biopsy were performed. DILI caused by iodine-131 was suspected. Oral prednisolone was started at 30 mg/day, to which the patient responded well. PMID:27209646

  13. Drug-induced liver injury caused by iodine-131.

    PubMed

    Kim, Chei Won; Park, Ji Sun; Oh, Se Hwan; Park, Jae-Hyung; Shim, Hyun-Ik; Yoon, Jae Woong; Park, Jin Seok; Hong, Seong Bin; Kim, Jun Mi; Le, Trong Binh; Lee, Jin Woo

    2016-06-01

    Iodine-131 is a radioisotope that is routinely used for the treatment of differentiated thyroid cancer after total or near-total thyroidectomy. However, there is some evidence that iodine-131 can induce liver injury . Here we report a rare case of drug-induced liver injury (DILI) caused by iodine-131 in a patient with regional lymph node metastasis after total thyroidectomy. A 47-year-old woman was admitted with elevated liver enzymes and symptoms of general weakness and nausea. Ten weeks earlier she had undergone a total thyroidectomy for papillary thyroid carcinoma and had subsequently been prescribed levothyroxine to reduce the level of thyroid-stimulating hormone. Eight weeks after surgery she underwent iodine-131 ablative therapy at a dose of 100 millicuries, and subsequently presented with acute hepatitis after 10 days. To rule out all possible causative factors, abdominal ultrasonography, endoscopic ultrasonography (on the biliary tree and gall bladder), and a liver biopsy were performed. DILI caused by iodine-131 was suspected. Oral prednisolone was started at 30 mg/day, to which the patient responded well.

  14. Evidence and Recommendations for Imaging Liver Fat in Children, Based upon Systematic Review

    PubMed Central

    Awai, Hannah I.; Newton, Kimberly P.; Sirlin, Claude B.; Behling, Cynthia; Schwimmer, Jeffrey B.

    2013-01-01

    Background & Aims Fatty liver is a common problem in children, and increases their risk for cirrhosis, diabetes, and cardiovascular disease. Liver biopsy is the clinical standard for diagnosing and grading fatty liver. However, non-invasive imaging modalities are needed to assess liver fat in children. We performed a systematic review of studies that evaluated imaging of liver fat in children. Methods We searched PubMed for original research articles in peer-reviewed journals from January 1, 1982 through December 31, 2012 using the key words “imaging liver fat.” Studies included those in English, and those performed in children from birth to 18 y of age. To be eligible for inclusion, studies were required to measure hepatic steatosis via an imaging modality and a quantitative comparator as the reference standard. Results We analyzed 9 studies comprising 610 children; 4 studies assessed ultrasonography and 5 assessed magnetic resonance imaging (MRI). Ultrasonography was used in the diagnosis of fatty liver with positive predictive values of 47–62%. There was not a consistent relationship between ultrasound steatosis score and the reference measurement of hepatic steatosis. Liver fat as measurements by MRI or by spectroscopy varied with the methodologies used. Liver fat measurements by MRI correlated with results from histologic analyses, but sample size did not allow for assessment of diagnostic accuracy. Conclusions Available evidence does not support the use of ultrasonography for the diagnosis or grading of fatty liver in children. Although MRI is a promising approach, the data are insufficient to make evidence-based recommendations regarding its use in children for assessment of hepatic steatosis. PMID:24090729

  15. Evidence and recommendations for imaging liver fat in children, based on systematic review.

    PubMed

    Awai, Hannah I; Newton, Kimberly P; Sirlin, Claude B; Behling, Cynthia; Schwimmer, Jeffrey B

    2014-05-01

    Fatty liver is a common problem in children and increases their risk for cirrhosis, diabetes, and cardiovascular disease. Liver biopsy is the clinical standard for diagnosing and grading fatty liver. However, noninvasive imaging modalities are needed to assess liver fat in children. We performed a systematic review of studies that evaluated imaging liver fat in children. We searched PubMed for original research articles in peer-reviewed journals from January 1, 1982, through December 31, 2012, using the key words "imaging liver fat." Studies included those in English, and those performed in children from birth to 18 years of age. To be eligible for inclusion, studies were required to measure hepatic steatosis via an imaging modality and a quantitative comparator as the reference standard. We analyzed 9 studies comprising 610 children; 4 studies assessed ultrasonography and 5 studies assessed magnetic resonance imaging (MRI). Ultrasonography was used in the diagnosis of fatty liver with positive predictive values of 47% to 62%. There was not a consistent relationship between ultrasound steatosis score and the reference measurement of hepatic steatosis. Liver fat as measurements by MRI or by spectroscopy varied with the methodologies used. Liver fat measurements by MRI correlated with results from histologic analyses, but sample size did not allow for an assessment of diagnostic accuracy. Available evidence does not support the use of ultrasonography for the diagnosis or grading of fatty liver in children. Although MRI is a promising approach, the data are insufficient to make evidence-based recommendations regarding its use in children for the assessment of hepatic steatosis. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. Robot-assisted laparoscopic ultrasonography for hepatic surgery.

    PubMed

    Schneider, Caitlin M; Peng, Peter D; Taylor, Russell H; Dachs, Gregory W; Hasser, Christopher J; DiMaio, Simon P; Choti, Michael A

    2012-05-01

    This study describes and evaluates a novel, robot-assisted laparoscopic ultrasonographic device for hepatic surgery. Laparoscopic liver surgery is being performed with increasing frequency. One major drawback of this approach is the limited capability of intraoperative ultrasonography (IOUS) using standard laparoscopic devices. Robotic surgery systems offer the opportunity to develop new tools to improve techniques in minimally invasive surgery. This study evaluates a new integrated ultrasonography (US) device with the da Vinci Surgical System for laparoscopic visualization, comparing it with conventional handheld laparoscopic IOUS for performing key tasks in hepatic surgery. A prototype laparoscopic IOUS instrument was developed for the da Vinci Surgical System and compared with a conventional laparoscopic US device in simulation tasks: (1) In vivo porcine hepatic visualization and probe manipulation, (2) lesion detection accuracy, and (3) biopsy precision. Usability was queried by poststudy questionnaire. The robotic US proved better than conventional laparoscopic US in liver surface exploration (85% success vs 73%; P = .030) and tool manipulation (79% vs 57%; P = .028), whereas no difference was detected in lesion identification (63 vs 58; P = .41) and needle biopsy tasks (57 vs 48; P = .11). Subjects found the robotic US to facilitate better probe positioning (80%), decrease fatigue (90%), and be more useful overall (90%) on the post-task questionnaire. We found this robot-assisted IOUS system to be practical and useful in the performance of important tasks required for hepatic surgery, outperforming free-hand laparoscopic IOUS for certain tasks, and was more subjectively usable to the surgeon. Systems such as this may expand the use of robotic surgery for complex operative procedures requiring IOUS. Copyright © 2012 Mosby, Inc. All rights reserved.

  17. Serum Fetuin-A levels in obese children with biopsy proven nonalcoholic fatty liver disease.

    PubMed

    Pampanini, V; Inzaghi, E; Germani, D; Alterio, A; Puglianiello, A; Alisi, A; Nobili, V; Cianfarani, S

    2018-01-01

    Fetuin-A has been proposed as a marker of liver damage in adults with obesity-related NAFLD. The aim of this study was to test serum fetuin-A concentrations in obese children with NAFLD diagnosed either by ultrasonography or by liver biopsy and to determine its applicability as predictive tool in pediatric NAFLD. Metabolic parameters and fetuin-A levels were investigated in 81 obese children with NAFLD diagnosed by biopsy, 79 obese children with NAFLD defined by liver ultrasonography and 23 lean subjects. Serum fetuin-A correlated significantly with age, waist circumference, systolic blood pressure, fasting insulin and 2-h postload insulin during OGTT, HOMA-IR, ISI, CRP, and apo B levels. Obese children with NAFLD detected by ultrasonography had significantly higher fetuin-A levels compared to those with normal liver. In obese children who underwent liver biopsy, no significant differences were detected in fetuin-A levels between subject with nonalcoholic steatohepatitis and those with simple steatosis. Fetuin-A was not different between obese and lean children. Fetuin-A is not related with the degree of liver damage in obese children with NAFLD and its routine measurement as marker of liver disease severity is therefore not recommended. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  18. Ultrasonographic features of the liver with cystic echinococcosis in sheep

    PubMed Central

    Hussein, Hussein Awad; Elrashidy, Mohammed

    2014-01-01

    Objectives The present study was designed to gain information about the ultrasonographic features of livers with cystic echinococcosis, as well as to evaluate the use of ultrasonography for diagnosis of such disease in sheep. Design This was a retrospective study during the period April 2011 to March 2013. Participants A total of 22 Baladi sheep (aged three to six years) were included in this study. Based on clear hepatic ultrasonographic findings, all animals were classified into two groups: those with hepatic cysts (n=9) and without liver cysts (healthy liver, n=13). Results Biochemically, serum concentrations of γ-glutamyl transferase, aspartate aminotransferase, total bilirubin and globulins were significantly increased (P<0.01), while albumin was lowered (P<0.01) in sheep with cystic livers. Ultrasonographic findings of diseased sheep livers revealed the presence of rounded, anechoic and unilocular hydatid cysts with ellipse circumference ranged from 6–10 cm. The borders of cysts were mostly well defined. The interior of cysts contained echogenic particulate materials, septations, or fine echoes. At the 10th intercostal space, the ventral margin, size, thickness and angle of livers were higher (P<0.01), while the diameter of portal vein was lower (P<0.01) in sheep with liver cysts than control ones. Furthermore, at the 9th intercostal space, the circumference of the gall bladder was decreased in sheep with hepatic cysts (P<0.01). The sensitivity, specificity, and positive and negative predictive values of ultrasonography for diagnosis of hepatic hydatid cysts were 80 per cent and 100 per cent, and 100 per cent and 83 per cent, respectively. Conclusions Cystic echinococcosis is associated with a number of anatomical alterations in the liver tissues that can be easily recognised by ultrasound. Furthermore, ultrasonography alone or in combination with analysis of biochemical parameters reflecting liver function could be helpful for diagnosis of hepatic

  19. High-definition flow Doppler ultrasonographic technique to assess hepatic vasculature compared with color or power Doppler ultrasonography: preliminary experience.

    PubMed

    Kim, Se Hyung; Lee, Jeong Min; Kim, Young Jun; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn

    2008-10-01

    The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers. High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed. Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU. The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.

  20. Radiologic evaluation of nonalcoholic fatty liver disease

    PubMed Central

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  1. Mesothelial cyst in the liver round ligament: A case report and review of the literature.

    PubMed

    Feo, Claudio F; Ginesu, Giorgio C; Cherchi, Giuseppe; Fancellu, Alessandro; Cossu, M Laura; Porcu, Alberto

    2017-01-01

    Cysts of the liver round ligament are rare and they are benign in the majority of cases. Current literature has been reviewed on this subject. A 22-year-old woman with a history of epigastric pain was admitted at our institution. Computed tomography (CT) of the abdomen showed a 14-mm cystic lesion in the epigastrium. A large cyst of the liver round ligament was successfully removed during exploratory laparoscopy and histopathology revealed a benign mesothelial cyst. Mesothelial cysts of the liver round ligament are rare entities and we found a total of 5 cases from the literature. Diameter varies from 5 to 14cm. Most patients were asymptomatic or may complain abdominal pain in the upper quadrants. Ultrasonography and CT scan are the most useful diagnostic tools, however differential diagnosis between various abdominal cystic lesions can be difficult. Treatment is usually surgical excision. Mesothelial cysts of the liver round ligament are extremely rare but should be taken in consideration in the differential diagnosis of intra-abdominal cystic lesions. We stress the importance of exploratory laparoscopy that can allow both diagnosis and radical surgical excision. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Imaging features of non-traumatic vascular liver emergencies.

    PubMed

    Onur, Mehmet Ruhi; Karaosmanoglu, Ali Devrim; Akca, Onur; Ocal, Osman; Akpinar, Erhan; Karcaaltincaba, Musturay

    2017-05-01

    Acute non-traumatic liver disorders can originate from abnormalities of the hepatic artery, portal vein and hepatic veins. Ultrasonography and computed tomography can be used in non-traumatic acute vascular liver disorders according to patient status, indication and appropriateness of imaging modality. Awareness of the imaging findings, in the appropriate clinical context, is crucial for prompt and correct diagnosis, as delay may cause severe consequences with significant morbidity and mortality. This review article will discuss imaging algorithms, and multimodality imaging findings for suspected acute vascular disorders of the liver.

  3. Interfraction Liver Shape Variability and Impact on GTV Position During Liver Stereotactic Radiotherapy Using Abdominal Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eccles, Cynthia L., E-mail: cynthia.eccles@rob.ox.ac.uk; Dawson, Laura A.; Moseley, Joanne L.

    2011-07-01

    Purpose: For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. Methods and Materials: Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCTmore » scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). Results: We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Conclusions: Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid

  4. [Physiology and pathology of reproduction in domesticated New World camelids with special emphasis on ultrasonography].

    PubMed

    Hoops, M; Kauffold, J

    2013-01-01

    The number of New World camelids in Germany is increasing. Owners and breeders are usually well educated regarding their animals. For practitioners, this means being up-to-date with respect to their veterinary knowledge. This includes the physiology and pathology of reproduction. Specifics of reproduction in domesticated New World camelids are an induced ovulation, the absence of cyclic sexual activity, a relatively long gestation of 336-349 days and a predominantly left-horn gestation. Ultrasonography plays an important role as part of the gynecological examination. Generally, the ultrasonographic examination can be performed transrectally and transcutaneously in the left or right flanks. Transrectal ultrasonography has to be carried out with particular caution to avoid rectal injuries. An accurate pregnancy diagnosis by transrectal scanning is possible starting from day 20 of pregnancy; using transcutaneous scanning, diagnosis is accurate starting on days 50-60 (left flank) or from day 90 (right flank) of pregnancy, respectively. Ultrasonography is also appropriate to examine the non-gravid uterus and the ovaries. Based on 5 years of experience working with farmed New World camelids, the article describes the physiology and pathology of reproduction in domesticated New World camelids. Particular consideration is given to the ultrasonographical examination of the genital organs.

  5. LIVER ULTRASONOGRAPHY IN DOLPHINS: USE OF ULTRASONOGRAPHY TO ESTABLISH A TECHNIQUE FOR HEPATOBILIARY IMAGING AND TO EVALUATE METABOLIC DISEASE-ASSOCIATED LIVER CHANGES IN BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS).

    PubMed

    Seitz, Kelsey E; Smith, Cynthia R; Marks, Stanley L; Venn-Watson, Stephanie K; Ivančić, Marina

    2016-12-01

    The objective of this study was to establish a comprehensive technique for ultrasound examination of the dolphin hepatobiliary system and apply this technique to 30 dolphins to determine what, if any, sonographic changes are associated with blood-based indicators of metabolic syndrome (insulin greater than 14 μIU/ml or glucose greater than 112 mg/dl) and iron overload (transferrin saturation greater than 65%). A prospective study of individuals in a cross-sectional population with and without elevated postprandial insulin levels was performed. Twenty-nine bottlenose dolphins ( Tursiops truncatus ) in a managed collection were included in the final data analysis. An in-water ultrasound technique was developed that included detailed analysis of the liver and pancreas. Dolphins with hyperinsulinemia concentrations had larger livers compared with dolphins with nonelevated concentrations. Using stepwise, multivariate regression including blood-based indicators of metabolic syndrome in dolphins, glucose was the best predictor of and had a positive linear association with liver size (P = 0.007, R 2 = 0.24). Bottlenose dolphins are susceptible to metabolic syndrome and associated complications that affect the liver, including fatty liver disease and iron overload. This study facilitated the establishment of a technique for a rapid, diagnostic, and noninvasive ultrasonographic evaluation of the dolphin liver. In addition, the study identified ultrasound-detectable hepatic changes associated primarily with elevated glucose concentration in dolphins. Future investigations will strive to detail the pathophysiological mechanisms for these changes.

  6. Liver in the analysis of body composition by dual-energy X-ray absorptiometry

    PubMed Central

    Bazzocchi, A; Diano, D; Albisinni, U; Marchesini, G; Battista, G

    2014-01-01

    Objective: To investigate the predictive value for hepatic steatosis of a new software for the quantification of visceral fat by dual-energy X-ray absorptiometry (DXA) and to design new regions of interest (ROIs). Methods: Adult volunteers were prospectively screened for hepatic steatosis by ultrasonography to obtain a well-balanced population according to the presence/absence of the disease. 90 adult patients without steatosis and 90 with steatosis (mild, 53.3%; moderate, 37.7%; and severe, 10.0%) were recruited. On the same day, all subjects were submitted to blood testing and to anthropometric and whole-body DXA for body composition evaluation. A new software for android visceral fat assessment was employed, and six new “liver-suited” ROIs as well as two modified android ROIs were designed. Their association with steatosis grade was tested by correlation analysis. Results: Fat mass (FM) of the new ROIs showed the highest correlation coefficients with steatosis grade (ρ = 0.610–0.619; p < 0.001), which was also confirmed by multivariate analysis. On the whole population, the new ROIs maintained the highest predictive role for liver steatosis, with areas under the receiver operating characteristic curve up to 0.820 ± 0.032. Inter- and intra-operator agreement for the new ROIs was excellent (k = 0.915–1.000 and k = 0.927–1.000). Conclusion: New ROIs could be designed, standardized and implemented in DXA whole-body scan to provide more specific and predictive values of hepatic lipid content. Advances in knowledge: This is the first study to investigate the predictive value for hepatic steatosis of visceral and regional FM assessed on the hepatic site by DXA in comparison with ultrasonography, anthropometry and surrogate markers derived by previously validated algorithms (fatty liver index). PMID:24919499

  7. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification.

    PubMed

    Lee, Dong Ho

    2017-12-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method.

  8. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification

    PubMed Central

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method. PMID:28994271

  9. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    PubMed

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a

  10. Ultrasonography and progesterone concentration at a single time point for the detection of puberty in dairy heifers.

    PubMed

    Archbold, H; Buckley, F; Pierce, K M; Begley, N; Mee, J F

    2012-06-01

    Data were available from 1657 heifers across 48 dairy farms which were visited once, on average 9 days (± 5.2) prior to the mating start date (23 April, ± 12.6). Blood samples were collected via coccygeal venepuncture for progesterone (P4) analysis, and animals were scanned for the presence or absence of corpora lutea (CL), to determine the luteal status. A comparison of luteal status between ultrasound (CL identified) and P4 (≥ 1 ng/ml), based on a single measurement point, showed poor agreement (K = 0.32). The majority of animals were classified as luteal (76%) using both ultrasonography and P4. There was excellent agreement between luteal status detected by ultrasonography alone and luteal status assigned by a combination of ultrasonography and P4 (K = 0.93). The agreement between luteal status assigned by P4 and luteal status assigned by the combination of ultrasonography and P4 was poor (K = 0.37). These results indicate that at a single examination, ultrasonography is the preferred modality to determine the luteal status of maiden heifers. © 2011 Blackwell Verlag GmbH.

  11. Tissue ablation accelerated by peripheral scanning mode with high-intensity focused ultrasound: a study on isolated porcine liver perfusion.

    PubMed

    Bu, Rui; Yin, Li; Yang, Han; Wang, Qi; Wu, Feng; Zou, Jian Zhong

    2013-08-01

    The aims of this study were to investigate the feasibility of accelerated tissue ablation using a peripheral scanning mode with high-intensity focused ultrasound (HIFU) and to explore the effect of flow rate on total energy consumption of the target tissues. Using a model of isolated porcine liver perfusion via the portal vein and hepatic artery, we conducted a scanning protocol along the periphery of the target tissues using linear-scanned HIFU to carefully adjust the varying focal depth, generator power, scanning velocity and line-by-line interval over the entire ablation range. Porcine livers were divided into four ablation groups: group 1, n = 12, with dual-vessel perfusion; group 2, n = 11, with portal vein perfusion alone; group 3, n = 10, with hepatic artery perfusion alone; and group 4, n = 11, control group with no-flow perfusion. The samples were cut open consecutively at a thickness of 3 mm, and the actual ablation ranges were calculated along the periphery of the target tissues after triphenyl tetrazolium chloride staining. Total energy consumption was calculated as the sum of the energy requirements at various focal depths in each group. On the basis of the pre-supposed scanning protocol, the peripheral region of the target tissue formed a complete coagulation necrosis barrier in each group with varying dose combinations, and the volume of the peripheral necrotic area did not differ significantly among the four groups (p > 0.05). Furthermore, total energy consumption in each group significantly decreased with the corresponding decrease in flow rate (p < 0.01). This study revealed that the complete peripheral necrosis barrier within the target tissues can defined using linear-scanned HIFU in an isolated porcine liver perfusion model. Additionally, the flow rate in the major hepatic vessels may play an important role in the use of the peripheral ablation mode, and this novel mode of ablation may enhance the therapeutic efficacy and tolerability of the

  12. Clinical Utility of High-Frequency Musculoskeletal Ultrasonography in Foot and Ankle Pathology: How Ultrasound Imaging Influences Diagnosis and Management.

    PubMed

    Delzell, Patricia B; Tritle, Benjamin A; Bullen, Jennifer A; Chiunda, Stella; Forney, Michael C

    The use of high-frequency (high-resolution) musculoskeletal ultrasonography is increasing and has shown promising utility in many areas of medicine. The utility of musculoskeletal ultrasonography for foot and ankle complaints has not been widely investigated, however. Although some conditions of the foot and ankle are easily diagnosed by physical examination, others can have nonspecific examination findings, making optimal treatment decisions difficult. We hypothesized that high-resolution musculoskeletal ultrasound scanning of the foot and ankle can affect the diagnosis and/or treatment for patients presenting with foot or ankle complaints. Retrospectively, the cases of 98 patients who had undergone musculoskeletal ultrasound scanning of the foot or ankle were reviewed. The pre-ultrasound clinical diagnosis and treatment were compared with the post-ultrasound diagnosis and treatment. In 64% of the patients, the diagnosis or treatment changed after the ultrasound examination. In 43% of patients, both the diagnosis and the treatment changed after ultrasound scanning. For those patients for whom the diagnosis and treatment were unchanged after the ultrasound examination, the ultrasound findings were concordant with the pre-ultrasound clinical diagnosis for 100% of the patients. These results suggest that in a large proportion of patients, high-resolution musculoskeletal ultrasonography of the foot or ankle can facilitate appropriate diagnosis and management. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Portal vein thrombosis and liver abscess due to Lactococcus lactis.

    PubMed

    Güz, Galip; Yeğin, Zeynep Arzu; Doğan, Ibrahim; Hizel, Kenan; Bali, Musa; Sindel, Sükrü

    2006-06-01

    A 26-year-old man was admitted with fever and abdominal pain. Abdominal ultrasonography and Doppler ultrasound eventually revealed portal vein thrombosis and a pyogenic liver abscess (17x11x11 cm). Lactococcus lactis was isolated from a culture of the abscess material. This organism is not a common pathogen in humans. This is the first published description of portal vein thrombosis and pyogenic liver abscess due to L. lactis.

  14. Hepatoprotective effects of Spirulina maxima in patients with non-alcoholic fatty liver disease: a case series

    PubMed Central

    2010-01-01

    Introduction Non-alcoholic fatty liver diseases range from simple steatosis to non-alcoholic steatohepatitis. The "two hits" hypothesis is widely accepted for its pathogenesis: the first hit is an increased fat flux to the liver, which predisposes our patient to a second hit where increasing free fatty acid oxidation into the mitochondria leads to oxidative stress, lipoperoxidation and a chain reaction with increased ROS. Clinical indications include abdominal cramps, meteorism and fatigue. Most patients, however, are asymptomatic, and diagnosis is based on aminotransferase elevation and ultrasonography (or "brilliant liver"). Spirulina maxima has been experimentally proven to possess in vivo and in vitro hepatoprotective properties by maintaining the liver lipid profile. This case report evaluates the hepatoprotective effects of orally supplied Spirulina maxima. Case presentation Three Hispanic Mexican patients (a 43-year-old man, a 77-year-old man and a 44-year-old woman) underwent ultrasonography and were treated with 4.5 g/day of Spirulina maxima for three months. Their blood samples before and after the treatment determined triacylglycerols, total cholesterol, high-density lipoprotein cholesterol, alanine aminotransferase and low-density lipoprotein cholesterol levels. The results were assessed using ultrasound. Conclusion Treatment had therapeutic effects as evidenced by ultrasonography and the aminotransferase data. Hypolipidemic effects were also shown. We conclude that Spirulina maxima may be considered an alternative treatment for patients with non-alcoholic fatty liver diseases and dyslipidemic disorder. PMID:20370930

  15. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties

    NASA Astrophysics Data System (ADS)

    Cournane, S.; Cannon, L.; Browne, J. E.; Fagan, A. J.

    2010-10-01

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al2O3 and 3 µm Al2O3, were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s-1, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  16. Unusual biliary scan appearance in a child with a transplanted liver with hepatic arterial thrombosis: a case report.

    PubMed

    Porn, U; Howman-Giles, R; Shun, A; Dorney, S; Uren, R

    2000-02-01

    A 5-year-old girl with biliary atresia and a subsequent Kasai procedure is described. She had clinical symptoms suggestive of rejection after a recent orthotopic liver transplant A hepatobiliary scan showed partial hepatic infarction and a biloma in the infarcted area.

  17. Accuracy of transient elastography-FibroScan®, acoustic radiation force impulse (ARFI) imaging, the enhanced liver fibrosis (ELF) test, APRI, and the FIB-4 index compared with liver biopsy in patients with chronic hepatitis C.

    PubMed

    Ragazzo, Taisa Grotta; Paranagua-Vezozzo, Denise; Lima, Fabiana Roberto; de Campos Mazo, Daniel Ferraz; Pessoa, Mário Guimarães; Oliveira, Claudia Pinto; Alves, Venancio Avancini Ferreira; Carrilho, Flair José

    2017-10-01

    Although liver biopsy is the gold standard for determining the degree of liver fibrosis, issues regarding its invasiveness and the small amount of liver tissue evaluated can limit its applicability and interpretation in clinical practice. Non-invasive evaluation methods for liver fibrosis can address some of these limitations. The aim of this study was to evaluate the accuracy of transient elastography-FibroScan®, acoustic radiation force impulse (ARFI), enhanced liver fibrosis (ELF), the aspartate aminotransferase-to-platelet ratio index (APRI), and the FIB-4 index compared with liver biopsy in hepatitis C. We evaluated chronic hepatitis C patients who were followed at the Division of Clinical Gastroenterology and Hepatology, Hospital das Clínicas, Department of Gastroenterology of University of São Paulo School of Medicine, São Paulo, Brazil, and who underwent liver biopsy. The accuracy of each method was determined by a receiver operating characteristic (ROC) curve analysis, and fibrosis was classified as significant fibrosis (≥F2), advanced fibrosis (≥F3), or cirrhosis (F4). The Obuchowski method was also used to determine the diagnostic accuracy of each method at the various stages of fibrosis. In total, 107 FibroScan®, 51 ARFI, 68 ELF, 106 APRI, and 106 FIB-4 analyses were performed. A total of 107 patients were included in the study. The areas under the ROC curve (AUROCs) according to fibrosis degree were as follows: significant fibrosis (≥F2): FibroScan®: 0.83, FIB-4: 0.76, ELF: 0.70, APRI: 0.69, and ARFI: 0.67; advanced fibrosis (≥F3): FibroScan®: 0.85, ELF: 0.82, FIB-4: 0.77, ARFI: 0.74, and APRI: 0.71; and cirrhosis (F4): APRI: 1, FIB-4: 1, FibroScan®: 0.99, ARFI: 0.96, and ELF: 0.94. The accuracies of transient elastography, ARFI, ELF, APRI and FIB-4 determined by the Obuchowski method were F0-F1: 0.81, 0.78, 0.44, 0.72 and 0.67, respectively; F1-F2: 0.73, 0.53, 0.62, 0.60, and 0.68, respectively; F2-F3: 0.70, 0.64, 0.77, 0.60, and 0

  18. Solitary liver metastasis from follicular variant papillary thyroid carcinoma: A case report and literature review

    PubMed Central

    Djenic, Brano; Duick, Daniel; Newell, James O.; Demeure, Michael J.

    2014-01-01

    Introduction Papillary (PTC) and follicular (FTC) thyroid carcinomas, together known as differentiated thyroid carcinomas (DTC), are among the most curable of cancers. Sites of metastases from FTC are usually osseous and those from PTC are in regional nodal basins and the lungs. Visceral metastases are rare and when they do occur, they tend do so in multiple sites. We present the case of a patient with a follicular variant of PTC and a solitary metastasis to the liver then review the relevant literature. Presentation of case An otherwise healthy 68-year-old woman was diagnosed with follicular variant papillary thyroid cancer in 2003 and subsequently underwent thyroidectomy. The patient’s endocrinologist conducted surveillance of her thyroid cancer. In 2012, due to rise in thyroglobulin, a whole body radioiodine scan was obtained which revealed an iodine-avid left liver lobe mass. Three cycles of radioiodine ablation therapy were unsuccessful and eventually the patient was referred for surgical resection. Metastatic evaluation including a PET scan was negative with the exception of an isolated enhancing 4 cm mass in segment 4B of the liver. Anatomic segmental resection of liver was performed without complications. Intraoperative ultrasonography was used to guide resection of the liver mass. Pathology reports confirmed metastatic follicular variant of PTC. Surgical margins were free of tumor. Patient was discharged home and is doing well one year after surgery. The latest thyroglobulin level was undetectable. Discussion Post-operative surveillance by PCP, endocrinologist or surgeon for patients with thyroid carcinoma should be performed routinely. If identified, a solitary liver metastasis from primary thyroid carcinoma should be considered for surgical resection. Due to sparse data available in literature, collecting more data to establish algorithms for treatment of such rare metastatic cancers may be able to aid physicians to achieve better outcomes. Conclusion

  19. Correlation of brain ultrasonography scans to the neuromotor outcome of very-low-birth-weight infants during the first year of life.

    PubMed

    Karagianni, Paraskevi; Rallis, Dimitrios; Kyriakidou, Maria; Tsakalidis, Christos; Pratsiou, Paraskevi; Nikolaidis, Nikolaos

    2014-11-01

    To evaluate the consistency of the Hammersmith Infant Neurological Examination scores of very-low-birth-weight infants at 6 and 12 months of age and its correlation to cranial ultrasonography findings, we designed a prospective study between January 2005 and January 2008, in the tertiary Neonatal Unit of Aristotle University of Thessaloniki, Greece. All infants enrolled had a cranial ultrasonography performed at term. Preterm infants born at <32 weeks gestation with a birth weight <1500 g were eligible for the study. One hundred seventy-four infants were finally enrolled; out of those, 46 (26%) had an optimal score at 6 and 76 (44%) at 12 months of age. Mean global scores were 61 and 69 at 6 and 12 months, respectively. The Hammersmith Infant Neurological Examination score significantly increased between 6 and 12 months, equally in all ultrasonography groups. The presence of cystic periventricular leukomalacia was associated to lower scores and neurologic impairment. © The Author(s) 2013.

  20. Postoperative ultrasonography of the musculoskeletal system.

    PubMed

    Chun, Kyung Ah; Cho, Kil-Ho

    2015-07-01

    Ultrasonography of the postoperative musculoskeletal system plays an important role in the accurate diagnosis of abnormal lesions in the bone and soft tissues. Ultrasonography is a fast and reliable method with no harmful irradiation for the evaluation of postoperative musculoskeletal complications. In particular, it is not affected by the excessive metal artifacts that appear on computed tomography or magnetic resonance imaging. Another benefit of ultrasonography is its capability to dynamically assess the pathologic movement in joints, muscles, or tendons. This article discusses the frequent applications of musculoskeletal ultrasonography in various postoperative situations including those involving the soft tissues around the metal hardware, arthroplasty, postoperative tendons, recurrent soft tissue tumors, bone unions, and amputation surgery.

  1. [Insulin-like growth factor-binding protein-1: a new biochemical marker of nonalcoholic fatty liver disease?].

    PubMed

    Graffigna, Mabel Nora; Belli, Susana H; de Larrañaga, Gabriela; Fainboim, Hugo; Estepo, Claudio; Peres, Silvia; García, Natalia; Levalle, Oscar

    2009-03-01

    to assess the presence of nonalcoholic fatty liver disease in patients with risk factors for this pathology (obesity, dyslipidemia, metabolic syndrome and diabetes type 2) and to determine the role of insulin, HOMA index, insulin-like growth factor-binding protein-1, sex hormone-binding globulin and plasminogen activator inhibitor type 1, as biochemical markers. Ninety-one patients with risk factors for nonalcoholic fatty liver disease were evaluated. Serum transaminases, insulin, sex hormone-binding globulin, insulin-like growth factor-binding protein-1 and plasminogen activator inhibitor type 1 were measured. The diagnosis of fatty liver was performed by ultrasonography and liver biopsies were performed to 31 subjects who had steatosis by ultrasonography and high alanine aminotransferase. Nonalcoholic fatty liver disease was present in 65 out of 91 patients (71,4%). Liver biopsy performed to 31 subjects confirmed nonalcoholic steatohepatitis. Twenty-five patients had different degrees of fibrosis. Those individuals with fatty liver had higher waist circumference, serum levels of triglycerides, insulin and HOMA index, and lower serum insulin-like growth factor-binding protein-1 concentration. The degree ofhepatic steatosis by ultrasonography was positively correlated to waist circumference, triglycerides, insulin and HOMA index (p<0,003; p<0,003; p<0,002 and p<0,001, respectively), and was negatively correlated to HDL-cholesterol and insulin-like growth factor-binding protein-1 (p<0,025 and p<0,018, respectively). We found a high prevalence of NAFLD in patients with risk factors, most of them overweight or obese. Although SHBG and PAI-1 have a closely relationship to insulin resistance, they did not show to be markers of NAFLD. Regardless of low IGFBP-1 levels associated with NAFLD, serum IGFBP-1 measure is less accessible than insulin and triglycerides levels, HOMA index and waist circumference. Moreover, it is not a better marker for NAFLD than the above

  2. The value of ultrasonography alone in screening surveys of cystic echinococcosis in children in Turkey.

    PubMed

    Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z

    2006-12-01

    A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.

  3. Ultrasonography versus computed tomography for suspected nephrolithiasis.

    PubMed

    Smith-Bindman, Rebecca; Aubin, Chandra; Bailitz, John; Bengiamin, Rimon N; Camargo, Carlos A; Corbo, Jill; Dean, Anthony J; Goldstein, Ruth B; Griffey, Richard T; Jay, Gregory D; Kang, Tarina L; Kriesel, Dana R; Ma, O John; Mallin, Michael; Manson, William; Melnikow, Joy; Miglioretti, Diana L; Miller, Sara K; Mills, Lisa D; Miner, James R; Moghadassi, Michelle; Noble, Vicki E; Press, Gregory M; Stoller, Marshall L; Valencia, Victoria E; Wang, Jessica; Wang, Ralph C; Cummings, Steven R

    2014-09-18

    There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic

  4. Role of autoimmunity in nonviral chronic liver disease.

    PubMed

    Amarapurkar, D N; Amarapurkar, A D

    2000-11-01

    To evaluate the prevalence and clinical profile of autoimmune hepatitis (AIH) in patients with chronic liver disease. Four hundred and thirty five consecutive patient with chronic liver disease seen in our department from January 1997 to December 1998 were studied with detailed history and clinical examination. All the patients underwent liver function tests, ultrasonography, isotope liver scanning, viral markers, autoimmune markers ANA, ASMA, LKM1 and AMA (by immunofluorescence technique) and liver histology whenever permissible. Appropriate work up for Wilson's disease was done whenever suspected clinically. Diagnosis of autoimmune hepatitis was made by the composite scoring system by international autoimmune hepatitis group. Twenty out of the 435 patients met the criteria of definite autoimmune hepatitis and seven patient had probable autoimmune hepatitis. Forty out of 408 patients showed markers of autoimmunity positive but did not qualify diagnosis of AIH on composite scores. Demographic profile of 27 patients with autoimmune hepatitis was as follows; male:female ratio 1:8, mean age 39.8 +/- 13 years (Range 4-65 years); mode of presentation as cirrhosis 11/27 (40.7%), chronic hepatitis 12/27 (44.4%) and acute hepatitis 4/27 (14.8%). Elevated serum bilirubin levels were seen in 12 (44.4%) patients while mean serum aminotransferases levels were 249 +/- 343 and 262 +/- 418 respectively. Other disease associations seen were as follows: diabetes in 4 (14.8%), rheumatoid arthritis in 3 (11%), hypothyroidism in 2 (7.4%) and ulcerative colitis in 1 (3.7%). The pattern of autoimmune markers was ANA +ve 23/27 (85%) (+ve titres of ANA > 1:80 in adults and 1:20 in children), ASMA +ve in 16/27 (59.2%) (+ve titres of ASMA > 1:40) and LKM1 in 3 patients. AMA in tires less than 1:80 was found in 3 patients. Liver histology changes seen were lymphoplasmacytic infiltrates (100%), bridging necrosis (93%), liver cell rossetting (80%) and fibrosis with or without cirrhosis (50

  5. Role of B-scan ultrasonography in pre-operative cataract patients.

    PubMed

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  6. Ultrasonography of umbilical structures in clinically normal foals.

    PubMed

    Reef, V B; Collatos, C

    1988-12-01

    The umbilical arteries, urachus, and umbilical vein were scanned ultrasonographically in 13 clinically normal foals that ranged in age from 6 hours to 4 weeks. Sonograms were obtained using a 7.5-MHz sector scanner transducer placed across the midline of the ventral portion of the foal's abdominal wall. The umbilical vein was scanned from the umbilical stalk to its entrance into the hepatic parenchyma. The mean (+/- SD) diameter of the umbilical vein was 0.61 +/- 0.20 cm immediately cranial to the umbilical stalk, 0.52 +/- 0.19 cm midway between the umbilicus and liver, and 0.6 +/- 0.19 cm at the liver. The urachus and umbilical arteries were scanned from the umbilical stalk to the apex of the urinary bladder and had a mean total diameter of 1.75 +/- 0.37 cm at the bladder apex. The umbilical arteries also were scanned along either side of the bladder and had a mean diameter of 0.85 +/- 0.21 cm. These measurements and the ultrasonographic appearance of the internal umbilical structures from clinically normal foals can be used as references to diagnose abnormalities of the umbilical structures in neonatal foals.

  7. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings.

    PubMed

    Cheng, Y; Cai, Y; Wang, Y

    2014-01-01

    The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute-chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint.

  8. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    PubMed

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  9. Transient elastography for the diagnosis of liver fibrosis.

    PubMed

    de Lédinghen, Victor; Vergniol, Julien

    2010-11-01

    Transient elastography (FibroScan(®)) is a noninvasive method proposed for the assessment of liver fibrosis in patients with chronic liver diseases by measuring liver stiffness. It can be easily performed at the bedside or in the outpatient clinic with immediate results and good reproducibility. FibroScan is validated for the diagnosis of significant fibrosis and cirrhosis in chronic hepatitis C, in recurrence of hepatitis C after liver transplantation, in co-infected HIV-HCV patients, in chronic hepatitis B, in chronic cholestatic diseases, in alcoholic disease and in nonalcoholic fatty liver disease. FibroScan is an excellent tool for the early detection of cirrhosis and for the evaluation of portal hypertension, and may have prognostic value in this setting. FibroScan evaluates liver stiffness, which is related to fibrosis, but also inflammation and portal hypertension. Therefore, FibroScan values have to be interpreted according to clinical, biological and morphological data.

  10. Prenatal Imaging: Ultrasonography and Magnetic Resonance Imaging

    PubMed Central

    Reddy, Uma M.; Filly, Roy A.; Copel, Joshua A.

    2009-01-01

    The Eunice Kennedy Shriver National Institute of Child Health and Human Development held a workshop on September 18–19, 2006, to summarize the available evidence on the role and performance of current fetal imaging technology and to establish a research agenda. Ultrasonography is the imaging modality of choice for pregnancy evaluation due to its relatively low cost, real-time capability, safety, and operator comfort and experience. First-trimester ultrasonography extends the available window for fetal observation and raises the possibility of performing an early anatomic survey. Three-dimensional ultrasonography has the potential to expand the clinical application of ultrasonography by permitting local acquisition of volumes and remote review and interpretation at specialized centers. New advances allow performance of fetal magnetic resonance imaging (MRI) without maternal or fetal sedation, with improved characterization and prediction of prognosis of certain fetal central nervous system anomalies such as ventriculomegaly when compared with ultrasonography. Fewer data exist on the usefulness of fetal MRI for non–central nervous system anomalies. PMID:18591320

  11. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings

    PubMed Central

    Cheng, Y; Cai, Y

    2014-01-01

    Objective: The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. Methods: A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. Results: There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute–chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Conclusion: Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Advances in knowledge: Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint. PMID:24352708

  12. Large-for-size liver transplant: a single-center experience.

    PubMed

    Akdur, Aydincan; Kirnap, Mahir; Ozcay, Figen; Sezgin, Atilla; Ayvazoglu Soy, Hatice Ebru; Karakayali Yarbug, Feza; Yildirim, Sedat; Moray, Gokhan; Arslan, Gulnaz; Haberal, Mehmet

    2015-04-01

    The ideal ratio between liver transplant graft mass and recipient body weight is unknown, but the graft probably must weigh 0.8% to 2.0% recipient weight. When this ratio > 4%, there may be problems due to large-for-size transplant, especially in recipients < 10 kg. This condition is caused by discrepancy between the small abdominal cavity and large graft and is characterized by decreased blood supply to the liver graft and graft dysfunction. We evaluated our experience with large-for-size grafts. We retrospectively evaluated 377 orthotopic liver transplants that were performed from 2001-2014 in our center. We included 188 pediatric transplants in our study. There were 58 patients < 10 kg who had living-donor living transplant with graft-to-bodyweight ratio > 4%. In 2 patients, the abdomen was closed with a Bogota bag. In 5 patients, reoperation was performed due to vascular problems and abdominal hypertension, and the abdomen was closed with a Bogota bag. All Bogota bags were closed in 2 weeks. After closing the fascia, 10 patients had vascular problems that were diagnosed in the operating room by Doppler ultrasonography, and only the skin was closed without fascia closure. No graft loss occurred due to large-for-size transplant. There were 8 patients who died early after transplant (sepsis, 6 patients; brain death, 2 patients). There was no major donor morbidity or donor mortality. Large-for-size graft may cause abdominal compartment syndrome due to the small size of the recipient abdominal cavity, size discrepancies in vascular caliber, insufficient portal circulation, and disturbance of tissue oxygenation. Abdominal closure with a Bogota bag in these patients is safe and effective to avoid abdominal compartment syndrome. Early diagnosis by ultrasonography in the operating room after fascia closure and repeated ultrasonography at the clinic may help avoid graft loss.

  13. How useful is abdominal ultrasonography in dogs with diarrhoea?

    PubMed

    Mapletoft, E K; Allenspach, K; Lamb, C R

    2018-01-01

    To assess the utility of abdominal ultrasonography in the diagnostic work-up of dogs with diarrhoea. Retrospective cross-sectional study based on a referral population of dogs with diarrhoea. Associations between the clinical signs, use of abdominal ultrasonography, results of abdominal ultrasonography and subsequent work-up were examined. The utility of abdominal ultrasonography was scored as high, moderate, none or counterproductive based on review of medical records. Medical records of 269 dogs were reviewed, of which 149 (55%) had abdominal ultrasonography. The most frequent result was no ultrasonographic abnormalities affecting the intestine in 65 (44%) dogs. Ultrasonography results were associated with subsequent work-up as follows: (1) no detected abnormalities and dietary trial; (2) focal thickening of the intestinal wall, loss of intestinal wall layers or enlarged abdominal lymph nodes and ultrasound-guided fine-needle aspirates; (3) diffuse thickening of the intestinal wall or hyperechoic striations in the small intestinal mucosa and endoscopy; and (4) small intestinal foreign body and coeliotomy. Abdominal ultrasonography was considered to be diagnostic without further testing in only four (3%) dogs: two had a portosystemic shunt identified ultrasonographically, one had a linear foreign body and one had a perforated pyloric ulcer. Abdominal ultrasonography had moderate utility in 56 (38%) dogs and no utility in 79 (53%) dogs. Abdominal ultrasonography was considered counterproductive in 10 (7%) dogs because results were either falsely negative or falsely positive. These results should prompt clinicians to reconsider routine use of abdominal ultrasonography in dogs with diarrhoea. © 2017 British Small Animal Veterinary Association.

  14. LCC demons with divergence term for liver MRI motion correction

    NASA Astrophysics Data System (ADS)

    Oh, Jihun; Martin, Diego; Skrinjar, Oskar

    2010-03-01

    Contrast-enhanced liver MR image sequences acquired at multiple times before and after contrast administration have been shown to be critically important for the diagnosis and monitoring of liver tumors and may be used for the quantification of liver inflammation and fibrosis. However, over multiple acquisitions, the liver moves and deforms due to patient and respiratory motion. In order to analyze contrast agent uptake one first needs to correct for liver motion. In this paper we present a method for the motion correction of dynamic contrastenhanced liver MR images. For this purpose we use a modified version of the Local Correlation Coefficient (LCC) Demons non-rigid registration method. Since the liver is nearly incompressible its displacement field has small divergence. For this reason we add a divergence term to the energy that is minimized in the LCC Demons method. We applied the method to four sequences of contrast-enhanced liver MR images. Each sequence had a pre-contrast scan and seven post-contrast scans. For each post-contrast scan we corrected for the liver motion relative to the pre-contrast scan. Quantitative evaluation showed that the proposed method improved the liver alignment relative to the non-corrected and translation-corrected scans and visual inspection showed no visible misalignment of the motion corrected contrast-enhanced scans and pre-contrast scan.

  15. Early diagnosis of Budd-Chiari syndrome by computed tomography and ultrasonography: report of five cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baert, A.L.; Fevery, J.; Marchal, G.

    1983-03-01

    In 5 patients with Budd-Chiari syndrome, computed tomography after intravenous bolus injection of iodinated contrast agents demonstrated images not previously seen in other diseases. The images are compatible with stagnation of contrast material at the periphery of the liver. In 3 of the 5 cases, grey-scale ultrasonography failed to document the normal hepatic veins draining into the inferior caval vein, but showed an intrahepatic network of comma-shaped venous structures. It is proposed that these two noninvasive approaches can help in establishing an early diagnosis.

  16. The potential of ultrasonography in the evaluation of foot orthotics therapy.

    PubMed

    Petcu, Daniel; Mitrea, Delia Alexandrina; Bondor, Cosmina Ioana; Perciun, Elena Rodica

    2017-11-29

    Foot orthotics prescription is based on the foot functioning paradigms with tissue stress theory being in avant-garde. The main goal of orthotic therapy is to reduce the internal tissue's pathological stresses in the foot structures. Traditionally, ultrasound scanning technique depicts anatomic related data of both common and uncommon pathology encountered in the clinical practice, helping in diagnosing, treating and evaluating, which are equally important for the practitioners. Its accessibility, compared to biomechanical modelling, makes this technique a valuable tool in the field of foot and ankle disorders. Despite its user-dependent limitation, the ongoing technical progress improves the ability of ultrasonography as a highly advanced procedure in musculoskeletal imaging, being also a valuable searching tool for musculotendinous mechanics or morphological changes as a result of a conservative intervention. The aim of the present work was to perform a review of the state of the art concerning the usefulness of ultrasonography in the study of foot orthotic therapy and to analyze its effectiveness.

  17. Magnetic Resonance Imaging of Liver Metastasis.

    PubMed

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Liver Contrast-Enhanced Ultrasound Improves Detection of Liver Metastases in Patients with Pancreatic or Periampullary Cancer.

    PubMed

    Taimr, Pavel; Jongerius, Vivian L; Pek, Chulja J; Krak, Nanda C; Hansen, Bettina E; Janssen, Harry L A; Metselaar, Herold J; van Eijck, Casper H J

    2015-12-01

    The aim of this study is to provide a diagnostic performance evaluation of contrast-enhanced ultrasonography (CEUS) in detecting liver metastases in patients with suspected of pancreatic or periampullary cancer. Computed tomography (CT) is often insufficient for detection of liver metastases, but their presence plays a crucial role in the choice of therapy. Eighty-nine patients with suspected pancreatic or periampullary cancer were included in this prospective study with retrospective analysis. Patients underwent an abdominal CT and CEUS. Fifteen patients had liver metastases. The CT sensitivity was 73.3% (11/15), the specificity 93.2% (69/74), the positive predictive value (PPV) 68.8% (11/16) and the negative predictive value (NPV) 94.6% (69/73). Based on CEUS, the sensitivity was 80% (12/15), specificity 98.6% (73/74), PPV 92.3% (12/13) and NPV 96.1% (73/76). CEUS improved characterization of liver lesions in patients with suspected pancreatic or periampullary cancer compared with CT. CEUS can better detect benign liver lesions and distinguish false-positive or indeterminate CT results. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Preoperative Duplex Scanning is a Helpful Diagnostic Tool in Neurogenic Thoracic Outlet Syndrome.

    PubMed

    Orlando, Megan S; Likes, Kendall C; Mirza, Serene; Cao, Yue; Cohen, Anne; Lum, Ying Wei; Freischlag, Julie A

    2016-01-01

    To evaluate the diagnostic role of venous and arterial duplex scanning in neurogenic thoracic outlet syndrome (NTOS). Retrospective review of patients who underwent duplex ultrasonography prior to first rib resection and scalenectomy (FRRS) for NTOS from 2005 to 2013. Abnormal scans included ipsilateral compression (IC) with abduction of the symptomatic extremity (>50% change in subclavian vessel flow), contralateral (asymptomatic side) compression (CC) or bilateral compression (BC). A total of 143 patients (76% female, average age 34, range 13-59) underwent bilateral preoperative duplex scanning. Ipsilateral compression was seen in 44 (31%), CC in 12 (8%), and BC in 14 (10%). Seventy-three (51%) patients demonstrated no compression. Patients with IC more often experienced intraoperative pneumothoraces (49% vs. 25%, P < .05) and had positive Adson tests (86% vs. 61%, P < .02). Compression of the subclavian vein or artery on duplex ultrasonography can assist in NTOS diagnosis. Ipsilateral compression on abduction often correlates with Adson testing. © The Author(s) 2016.

  20. Point-of-care ultrasonography by pediatric emergency medicine physicians.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Emergency physicians have used point-of-care ultrasonography since the 1990 s. Pediatric emergency medicine physicians have more recently adopted this technology. Point-of-care ultrasonography is used for various scenarios, particularly the evaluation of soft tissue infections or blunt abdominal trauma and procedural guidance. To date, there are no published statements from national organizations specifically for pediatric emergency physicians describing the incorporation of point-of-care ultrasonography into their practice. This document outlines how pediatric emergency departments may establish a formal point-of-care ultrasonography program. This task includes appointing leaders with expertise in point-of-care ultrasonography, effectively training and credentialing physicians in the department, and providing ongoing quality assurance reviews. Copyright © 2015 by the American Academy of Pediatrics.

  1. Postnatal Brain Growth Assessed by Sequential Cranial Ultrasonography in Infants Born <30 Weeks' Gestational Age.

    PubMed

    Cuzzilla, R; Spittle, A J; Lee, K J; Rogerson, S; Cowan, F M; Doyle, L W; Cheong, J L Y

    2018-06-01

    Brain growth in the early postnatal period following preterm birth has not been well described. This study of infants born at <30 weeks' gestational age and without major brain injury aimed to accomplish the following: 1) assess the reproducibility of linear measures made from cranial ultrasonography, 2) evaluate brain growth using sequential cranial ultrasonography linear measures from birth to term-equivalent age, and 3) explore perinatal predictors of postnatal brain growth. Participants comprised 144 infants born at <30 weeks' gestational age at a single center between January 2011 and December 2013. Infants with major brain injury seen on cranial ultrasonography or congenital or chromosomal abnormalities were excluded. Brain tissue and fluid spaces were measured from cranial ultrasonography performed as part of routine clinical care. Brain growth was assessed in 3 time intervals: <7, 7-27, and >27 days' postnatal age. Data were analyzed using intraclass correlation coefficients and mixed-effects regression. A total of 429 scans were assessed for 144 infants. Several linear measures showed excellent reproducibility. All measures of brain tissue increased with postnatal age, except for the biparietal diameter, which decreased within the first postnatal week and increased thereafter. Gestational age of ≥28 weeks at birth was associated with slower growth of the biparietal diameter and ventricular width compared with gestational age of <28 weeks. Postnatal corticosteroid administration was associated with slower growth of the corpus callosum length, transcerebellar diameter, and vermis height. Sepsis and necrotizing enterocolitis were associated with slower growth of the transcerebellar diameter. Postnatal brain growth in infants born at <30 weeks' gestational age can be evaluated using sequential linear measures made from routine cranial ultrasonography and is associated with perinatal predictors of long-term development. © 2018 by American Journal of

  2. Controlled Attenuation Parameter and Liver Stiffness Measurements for Steatosis Assessment in the Liver Transplant of Brain Dead Donors.

    PubMed

    Mancia, Claire; Loustaud-Ratti, Véronique; Carrier, Paul; Naudet, Florian; Bellissant, Eric; Labrousse, François; Pichon, Nicolas

    2015-08-01

    One of the main selection criteria of the quality of a liver graft is the degree of steatosis, which will determine the success of the transplantation. The aim of this study was to evaluate the ability of FibroScan and its related methods Controlled Attenuation Parameter and Liver Stiffness to assess objectively steatosis and fibrosis in livers from brain-dead donors to be potentially used for transplantation. Over a period of 10 months, 23 consecutive brain dead donors screened for liver procurement underwent a FibroScan and a liver biopsy. The different predictive models of liver retrievability using liver biopsy as the gold standard have led to the following area under receiver operating characteristic curve: 76.6% (95% confidence intervals [95% CIs], 48.2%-100%) when based solely on controlled attenuation parameter, 75.0% (95% CIs, 34.3%-100%) when based solely on liver stiffness, and 96.7% (95% CIs, 88.7%-100%) when based on combined indices. Our study suggests that a preoperative selection of brain-dead donors based on a combination of both Controlled Attenuation Parameter and Liver Stiffness obtained with FibroScan could result in a good preoperative prediction of the histological status and degree of steatosis of a potential liver graft.

  3. Fatty Liver Index and Lipid Accumulation Product Can Predict Metabolic Syndrome in Subjects without Fatty Liver Disease

    PubMed Central

    Cheng, Yuan-Lung; Wang, Yuan-Jen; Lan, Keng-Hsin; Huo, Teh-Ia; Hsieh, Wei-Yao; Hou, Ming-Chih; Lee, Fa-Yauh; Wu, Jaw-Ching; Lee, Shou-Dong

    2017-01-01

    Background. Fatty liver index (FLI) and lipid accumulation product (LAP) are indexes originally designed to assess the risk of fatty liver and cardiovascular disease, respectively. Both indexes have been proven to be reliable markers of subsequent metabolic syndrome; however, their ability to predict metabolic syndrome in subjects without fatty liver disease has not been clarified. Methods. We enrolled consecutive subjects who received health check-up services at Taipei Veterans General Hospital from 2002 to 2009. Fatty liver disease was diagnosed by abdominal ultrasonography. The ability of the FLI and LAP to predict metabolic syndrome was assessed by analyzing the area under the receiver operating characteristic (AUROC) curve. Results. Male sex was strongly associated with metabolic syndrome, and the LAP and FLI were better than other variables to predict metabolic syndrome among the 29,797 subjects. Both indexes were also better than other variables to detect metabolic syndrome in subjects without fatty liver disease (AUROC: 0.871 and 0.879, resp.), and the predictive power was greater among women. Conclusion. Metabolic syndrome increases the cardiovascular disease risk. The FLI and LAP could be used to recognize the syndrome in both subjects with and without fatty liver disease who require lifestyle modifications and counseling. PMID:28194177

  4. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    PubMed

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  5. Effect of Provider Experience on Clinician-Performed Ultrasonography for Hydronephrosis in Patients With Suspected Renal Colic

    PubMed Central

    Herbst, Meghan K.; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P.; Singh, Dinesh; Molinaro, Annette M.; Luty, Seth; Moore, Christopher L.

    2016-01-01

    Study objective Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. Methods This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non–attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non–attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). Results There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95

  6. Effect of provider experience on clinician-performed ultrasonography for hydronephrosis in patients with suspected renal colic.

    PubMed

    Herbst, Meghan K; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P; Singh, Dinesh; Molinaro, Annette M; Luty, Seth; Moore, Christopher L

    2014-09-01

    Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non-attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non-attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78

  7. Changes of FibroScan, APRI, and FIB-4 in chronic hepatitis B patients with significant liver histological changes receiving 3-year entecavir therapy.

    PubMed

    Li, Qiang; Chen, Liang; Zhou, Yu

    2018-05-01

    Noninvasive fibrosis tests have been used widely for evaluation of liver fibrosis in patients with chronic hepatitis B (CHB). We aimed to investigate the influence of antiviral treatment on FibroScan, APRI, and FIB-4 in CHB patients with significant liver histological changes (SLHC) defined as inflammatory grade ≥ A2 and/or fibrosis stage ≥ F2. A total of 104 CHB patients with SLHC at the baseline were included. FibroScan, APRI, and FIB-4 values were compared before and after 3-year entecavir (ETV) treatment. Liver stiffness measurement values decreased significantly after 3-year ETV treatment in cirrhosis group (from 13.6 to 9.6 kPa, p = 0.018), significant fibrosis group (from 8.4 to 5.8 kPa, p = 0.001), and mild fibrosis group (from 5.5 to 4 kPa, p < 0.001). APRI decreased significantly after 3-year ETV treatment in patients with cirrhosis (from 0.80 to 0.25, p < 0.001), patients with significant fibrosis (from 0.54 to 0.24, p < 0.001), and those with mild fibrosis (from 0.35 to 0.23, p < 0.001). FIB-4 decreased significantly after 3-year ETV treatment in patients with cirrhosis (from 1.27 to 0.81, p = 0.007) and significant fibrosis (from 1.12 to 0.78, p < 0.001), while did not decrease significantly in patients with mild fibrosis (from 0.90 to 0.80, p = 0.389). FibroScan, APRI, and FIB-4 values decreased significantly after 3-year ETV treatment in CHB patients, which indicates that these noninvasive fibrosis tests might be useful for monitoring regression of liver fibrosis and assessing treatment efficacy during long-term ETV treatment.

  8. [The role of ultrasonography exam in orbital-ocular tumors].

    PubMed

    Ciocâlteu, Alina Mihaela; Ardeleanu, S; Checheriţă, I A

    2011-01-01

    Ophthalmology is one of the specialties that have particularly benefited from the contribution of ultrasonography exam as a method of investigation. Ultrasonography is very much essential for diagnostic to complement other clinical and laboratory investigations, providing images in real time. The basic principle of diagnostic ultrasound is to study and to interpret the changes they undergo when crossing ultrasonic waves diverse biological properties different sound, and such injuries can be traced in the dynamics or can be documented on photographic paper and thus can diagnose correct certain eye diseases. The indications for performing ultrasound consist in: measurement of distances and volumes, examine difficult or inaccessible case of opaque media; ophthalmoscopic view of a mass lesion, examine the orbit or optic nerve. The advantages of ultrasound for orbital-ocular tumors are represented by the fact that ultrasound is a noninvasive method, safe, well tolerated, less expensive that the advantage of determining the position and distance from structures ocular tumor. High frequency ultrasound provides excellent resolution of 0-1 to 0.01 mm, and serial scans allow tracking progress and measuring lesion diameters tumor while allowing monitoring and evaluation of stereotactic radiation treatments applied to small tumors. In conclusion ultrasound allows not only early diagnosis of eye tumors, but accurate assessment of the proposed therapy and of the evolution of detected mass lesions or tumors.

  9. Role of ultrasonography in the management of twin gestation.

    PubMed

    Smith, Jessica; Treadwell, Marjorie C; Berman, Deborah R

    2018-06-01

    Twins represent 1%-2% of all pregnancies, yet continue to account for a disproportionate share of neonatal adverse events including neonatal intensive care admission, morbidity, and mortality. Ultrasonography is central to the proper diagnosis of the type of twinning. Ideally, ultrasonography is performed before 14 weeks of gestation to determine chorionicity and amnionicity. Correct identification of the chorionicity in a twin pregnancy facilitates proper counseling and management of the gestation, including ultrasonography follow-up. Herein, the different types of twinning are reviewed, together with the implications for ultrasonography monitoring of each specific type of twin gestation. © 2018 International Federation of Gynecology and Obstetrics.

  10. Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernatowicz, Kinga, E-mail: kinga.bernatowicz@psi.ch; Proton Therapy Center, Paul Scherrer Institute, PSI Villigen; Peroni, Marta

    Purpose: Four-dimensional computed tomography-magnetic resonance imaging (4DCT-MRI) is an image-processing technique for simulating many 4DCT data sets from a static reference CT and motions extracted from 4DMRI studies performed using either volunteers or patients. In this work, different motion extraction approaches were tested using 6 liver cases, and a detailed comparison between 4DCT-MRI and 4DCT was performed. Methods and Materials: 4DCT-MRI has been generated using 2 approaches. The first approach used motion extracted from 4DMRI as being “most similar” to that of 4DCT from the same patient (subject-specific), and the second approach used the most similar motion obtained from amore » motion library derived from 4DMRI liver studies of 13 healthy volunteers (population-based). The resulting 4DCT-MRI and 4DCTs were compared using scanned proton 4D dose calculations (4DDC). Results: Dosimetric analysis showed that 93% ± 8% of points inside the clinical target volume (CTV) agreed between 4DCT and subject-specific 4DCT-MRI (gamma analysis: 3%/3 mm). The population-based approach however showed lower dosimetric agreement with only 79% ± 14% points in the CTV reaching the 3%/3 mm criteria. Conclusions: 4D CT-MRI extends the capabilities of motion modeling for dose calculations by accounting for realistic and variable motion patterns, which can be directly employed in clinical research studies. We have found that the subject-specific liver modeling appears more accurate than the population-based approach. The former is particularly interesting for clinical applications, such as improved target delineation and 4D dose reconstruction for patient-specific QA to allow for inter- and/or intra-fractional plan corrections.« less

  11. Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.

    PubMed

    Salmon, Benjamin; Le Denmat, Dominique

    2012-04-01

    Although ultrasonography is a non-invasive, inexpensive and painless diagnostic tool for soft tissue imaging, this technique is not currently used for oral exploration. Therefore, we developed a 25-MHz high-frequency ultrasound probe, specially designed for intraoral applications. This paper aims to present clinical intraoral ultrasound images actually interpretable, in order to identify the relevant applications of this novel tool and to design future oral studies. Two independent radiologists performed ultrasound examinations on three healthy volunteers. All the teeth were explored on the lingual and buccal sides (162 samples) to evaluate the ergonomics of the system and the visualisation of anatomic structures. Osseointegrated dental implants and a mucocele were also scanned. At the gingivodental junction of the maxillary and mandibular teeth, the device clearly identifies the tooth surfaces, the alveolar bone reflection with its surrounding subepithelial connective tissue of the gingiva and the gingival epithelia. The bone level and the thickness of soft tissue around the implant are measurable on the buccal and lingual sides. Therefore, intraoral ultrasonography provides additional morphological information that is not accessible by conventional dental x-rays. We propose a novel diagnostic tool that explores the biological width and is able to define the thin or thick nature of the gums. Moreover, intraoral ultrasonography may help to monitor precancerous lesions. This promising device requires large-scale clinical studies to determine whether it should remain a research tool or be used as a diagnostic tool for daily dental practice.

  12. Clients' reasons for prenatal ultrasonography in Ibadan, South West of Nigeria

    PubMed Central

    Enakpene, Christopher A; Morhason-Bello, Imran O; Marinho, Anthony O; Adedokun, Babatunde O; Kalejaiye, Adegoke O; Sogo, Kayode; Gbadamosi, Sikiru A; Awoyinka, Babatunde S; Enabor, Obehi O

    2009-01-01

    Background Prenatal ultrasonography has remained a universal tool but little is known especially from developing countries on clients' reasons for desiring it. Then aim was to determine the reasons why pregnant women will desire a prenatal ultrasound. Methods It was a cross-sectional survey of consecutive 222 women at 2 different ultrasonography facilities in Ibadan, South-west Nigeria. Results The mean age of the respondents was 30.1 ± 4.5 years. The commonest reason for requesting for prenatal ultrasound scans was to check for fetal viability in 144 women (64.7%) of the respondents, followed by fetal gender determination in 50 women (22.6%. Other reasons were to check for number of fetuses, fetal age and placental location. Factors such as younger age, artisans profession and low level of education significantly influenced the decision to check for fetal viability on bivariate analysis but all were not significant on multivariate analysis. Concerning fetal gender determination, older age, Christianity, occupation and gravidity were significant on bivariate analysis, however, only gravidity and occupation remained significant independent predictor on logistic regression model. Women with less than 3 previous pregnancies were about 4 times more likely to request for fetal sex determination than women with more than 3 previous pregnancies, (OR 3.8 95%CI 1.52 – 9.44). The professionals were 7 times more likely than the artisans to request to find out about their fetal sex, (OR 7.0 95%CI 1.47 – 333.20). Conclusion This study shows that Nigerian pregnant women desired prenatal ultrasonography mostly for fetal viability, followed by fetal gender determination. These preferences were influenced by their biosocial variables. PMID:19426518

  13. Toward surface quantification of liver fibrosis progression

    NASA Astrophysics Data System (ADS)

    He, Yuting; Kang, Chiang Huen; Xu, Shuoyu; Tuo, Xiaoye; Trasti, Scott; Tai, Dean C. S.; Raja, Anju Mythreyi; Peng, Qiwen; So, Peter T. C.; Rajapakse, Jagath C.; Welsch, Roy; Yu, Hanry

    2010-09-01

    Monitoring liver fibrosis progression by liver biopsy is important for certain treatment decisions, but repeated biopsy is invasive. We envision redefinition or elimination of liver biopsy with surface scanning of the liver with minimally invasive optical methods. This would be possible only if the information contained on or near liver surfaces accurately reflects the liver fibrosis progression in the liver interior. In our study, we acquired the second-harmonic generation and two-photon excitation fluorescence microscopy images of liver tissues from bile duct-ligated rat model of liver fibrosis. We extracted morphology-based features, such as total collagen, collagen in bile duct areas, bile duct proliferation, and areas occupied by remnant hepatocytes, and defined the capsule and subcapsular regions on the liver surface based on image analysis of features. We discovered a strong correlation between the liver fibrosis progression on the anterior surface and interior in both liver lobes, where biopsy is typically obtained. The posterior surface exhibits less correlation with the rest of the liver. Therefore, scanning the anterior liver surface would obtain similar information to that obtained from biopsy for monitoring liver fibrosis progression.

  14. Computer-aided diagnostic system for diffuse liver diseases with ultrasonography by neural networks

    NASA Astrophysics Data System (ADS)

    Ogawa, K.; Fukushima, M.; Kubota, K.; Hisa, N.

    1998-12-01

    The aim of the study is to establish a computer-aided diagnostic system for diffuse liver diseases such as chronic active hepatitis (CAH) and liver cirrhosis (LC). The authors introduced an artificial neural network in the classification of these diseases. In this system the neural network was trained by feature parameters extracted from B-mode ultrasonic images of normal liver (NL), CAH and LC. For input data the authors used six parameters calculated by a region of interest (ROI) and a parameter calculated by five ROIs in each image. They were variance of pixel values, coefficient of variation, annular Fourier power spectrum, longitudinal Fourier power spectrum which were calculated for the ROI, and variation of the means of the five ROIs. In addition, the authors used two more parameters calculated from a co-occurrence matrix of pixel values in the ROI. The results showed that the neural network classifier was 83.8% in sensitivity for LC, 90.0% in sensitivity for CAH and 93.6% in specificity, and the system was considered to be helpful for clinical and educational use.

  15. Clinical characteristics of patients with diabetes mellitus and fatty liver diagnosed by liver/spleen Hounsfield units on CT scan.

    PubMed

    Sakitani, Kosuke; Enooku, Kenichiro; Kubo, Hirokazu; Tanaka, Akifumi; Arai, Hisakatsu; Kawazu, Shoji; Koike, Kazuhiko

    2017-06-01

    Objective The leading cause of liver injuries in diabetes mellitus may be associated with fatty liver. We aimed to elucidate the relationship between fatty liver and diabetes characteristics. Methods Retrospectively, 970 patients with diabetes were analysed. Fatty liver was diagnosed when the liver/spleen Hounsfield unit ratio by computed tomography was below 0.9. Clinical diabetes characteristics were compared between patients with and without fatty liver. Results Of 970 patients (717 male and 253 female; mean age 64.4 years), 175 males (24.4%) and 60 females (23.7%) had fatty liver. None of the 28 patients with type 1 diabetes had fatty liver. In male patients with type 2 diabetes, age, visceral adipose tissue (VAT), albumin, alanine amino-transferase (ALT), and triglycerides were independently associated with fatty liver. In females, age and bilirubin were associated with fatty liver. Conclusions Fatty liver is associated with type 2 diabetes characteristics, including younger age and elevated VAT, albumin, ALT, and triglycerides in males and younger age and elevated bilirubin levels in females.

  16. Clinical characteristics of patients with diabetes mellitus and fatty liver diagnosed by liver/spleen Hounsfield units on CT scan

    PubMed Central

    Sakitani, Kosuke; Enooku, Kenichiro; Kubo, Hirokazu; Tanaka, Akifumi; Arai, Hisakatsu; Kawazu, Shoji; Koike, Kazuhiko

    2017-01-01

    Objective The leading cause of liver injuries in diabetes mellitus may be associated with fatty liver. We aimed to elucidate the relationship between fatty liver and diabetes characteristics. Methods Retrospectively, 970 patients with diabetes were analysed. Fatty liver was diagnosed when the liver/spleen Hounsfield unit ratio by computed tomography was below 0.9. Clinical diabetes characteristics were compared between patients with and without fatty liver. Results Of 970 patients (717 male and 253 female; mean age 64.4 years), 175 males (24.4%) and 60 females (23.7%) had fatty liver. None of the 28 patients with type 1 diabetes had fatty liver. In male patients with type 2 diabetes, age, visceral adipose tissue (VAT), albumin, alanine amino-transferase (ALT), and triglycerides were independently associated with fatty liver. In females, age and bilirubin were associated with fatty liver. Conclusions Fatty liver is associated with type 2 diabetes characteristics, including younger age and elevated VAT, albumin, ALT, and triglycerides in males and younger age and elevated bilirubin levels in females. PMID:28553763

  17. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    PubMed

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  18. Contrast-enhanced endoscopic ultrasonography: advance and current status

    PubMed Central

    2014-01-01

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805

  19. Vegetarian diet, food substitution, and nonalcoholic fatty liver.

    PubMed

    Chiu, Tina H; Lin, Ming-Nan; Pan, Wen-Harn; Chen, Yen-Ching; Lin, Chin-Lon

    2018-01-01

    Vegetarian diets have been shown to improve insulin resistance and reduce body weight, but the effects on nonalcoholic fatty liver require further confirmation. We aim to investigate the association between vegetarian diets, major food groups, and nonalcoholic fatty liver, and to compare the degree of liver fibrosis between vegetarians and nonvegetarians in those with fatty liver. We analyzed cross-sectional data from the Tzu Chi Health Study which included 2127 nonvegetarians and 1273 vegetarians who did not smoke or habitually drink alcohol and had no hepatitis B or hepatitis C. Fatty liver and liver fibrosis were determined using ultrasonography and the nonalcoholic fatty liver disease fibrosis score, respectively. Diet was assessed through a validated food frequency questionnaire. Vegetarian diets were associated with lower odds of fatty liver (odds ratio = 0.79, 95% confidence interval: 0.68-0.91) after adjusting for age, gender, education, history of smoking and alcohol drinking. Adjustment for body mass index (BMI) attenuated the protective association. Vegetarians had less severe fibrosis than nonvegetarians. Replacing a serving of soy with a serving of meat or fish was associated with 12%-13% increased risk, and replacing a serving of whole grains with a serving of refined grains, fruits, and fruit juice was associated with 3%-12% increased the risk of fatty liver. Vegetarian diets, replacing meat and fish with soy, and replacing refined carbohydrates with whole grains, may be inversely associated with nonalcoholic fatty liver related to BMI.

  20. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moschouris, Hippocrates, E-mail: hipmosch@gmail.co; Malagari, Katerina; Kornezos, Ioannis

    2010-12-15

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified accordingmore » to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.« less

  1. Scanning Electron Microscopy Findings of Machine Perfused Liver Graft After Warm Ischemia Between Hypothermic and Rewarming Machine Perfusion in Pigs.

    PubMed

    Meng, L; Matsuno, N; Watanabe, K; Furukori, M; Obara, H; Bochimoto, H; Watanabe, T; Fukukawa, H

    2016-09-01

    The shortage of organ donors is a universal problem. Use of grafts from donors after cardiac death would greatly contribute to the expansion of the donor organ pool. The two major methods of preservation are cold storage and machine perfusion (MP) preservation, and each has its own advantages. Several studies have reported the relative merits of MP for the preservation for grafts from donors after cardiac death. In this study, we used scanning electron microscopy (SEM) to assess the damage to the liver between hypothermic and rewarming preservation conditions. Porcine livers were perfused with a newly developed MP system. The livers were perfused for 4 hours with a modified University of Wisconsin solution-gluconate solution. In group 1, grafts were preserved with warm ischemic time for 60 minutes and hypothermic machine perfusion (HMP) for 4 hours. In group 2, grafts were preserved with warn ischemic time for 60 minutes and had rewarming up to 22°C by MP (RMP) for 4 hours. A significant enlargement of the mitochondria were observed in both the HMP and RMP groups under higher magnification, Additionally, vacuoles appeared occasionally in hepatocytes in the RMP for 4 hours group, but not in the HMP for 4 hours group. An analysis by scanning electron microscope appears to be useful to evaluate the levels of damage of hepatocytes compared with transmission electron microscopy, and further study is needed to analyze the significance of the appearance of swelling of mitochondria and vacuolization during preservation. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Postoperative pain management of liver transplantation in cystic fibrosis: Is it time to start US-guided neuraxial blocks?

    PubMed

    Piazza, M; Martucci, G; Arcadipane, A

    2016-01-01

    Cystic fibrosis (CF) is the most common life-limiting genetic disease in Caucasians. Declining lung function is the principal cause of death, but liver involvement can lead to the need for liver transplantation. General anesthesia has detrimental effects on pulmonary function, increasing perioperative morbidity and mortality in CF patients. Regional anesthetic techniques improve outcomes by reducing anesthetic drugs and administration of opioids, and hastening extubation, awakening, and restarting respiratory of physiotherapy. There is a growing evidence that thoracic epidural anesthesia is feasible in pediatric patients. Concerns about coagulopathy and immunosuppression have limited its use in liver transplantation. Ultrasonography is becoming an adjunct tool in neuraxial blocks, allowing faster and easier recognition of the epidural space, and reducing vertebral touch and number of attempts. In pediatric patients, it is still debated whether anesthesia has detrimental effects on cognitive development. Efforts to make regional techniques easier and safer by ultrasonography are ongoing. We report the first case of continuous thoracic epidural analgesia after pediatric liver transplantation in a 10-year-old boy affected with CF with macronodular cirrhosis. Despite a challenging coagulation profile, the echo-assisted procedure was safely performed and allowed extubation in the odds ratio, postoperative awakening and comfort, and quick resumption of respiratory physiotherapy.

  3. [Comparison of the M and XL FibroScan(®) probes to estimate liver stiffness by transient elastography].

    PubMed

    Herrero, José Ignacio; Iñarrairaegui, Mercedes; D'Avola, Delia; Sangro, Bruno; Prieto, Jesús; Quiroga, Jorge

    2014-04-01

    The FibroScan(®) XL probe has been specifically designed for obese patients to measure liver stiffness by transient elastography, but it has not been well tested in non-obese patients. The aim of this study was to compare the M and XL FibroScan(®) probes in a series of unselected obese (body mass index above 30 kg/m(2)) and non-obese patients with chronic liver disease. Two hundred and fifty-four patients underwent a transient elastography examination with both the M and XL probes. The results obtained with the two probes were compared in the whole series and in obese (n=82) and non-obese (n=167) patients separately. The reliability of the examinations was assessed using the criteria defined by Castéra et al. The proportion of reliable exams was significantly higher when the XL probe was used (83% versus 73%; P=.001). This significance was maintained in the group of obese patients (82% versus 55%; P<.001), but not in the non-obese patients (84% versus 83%). Despite a high correlation between the stiffness values obtained with the two probes (R=.897; P<.001), and a high concordance in the estimation of fibrosis obtained with the two probes (Cronbach's alpha value: 0.932), the liver stiffness values obtained with the XL probe were significantly lower than those obtained with the M probe, both in the whole series (9.5 ± 9.1 kPa versus 11.3 ± 12.6 kPa; P<0.001) and in the obese and non-obese groups. In conclusion, transient elastography with the XL probe allows a higher proportion of reliable examinations in obese patients but not in non-obese patients. Stiffness values were lower with the XL probe than with the M probe. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  4. The role of orbital ultrasonography in distinguishing papilledema from pseudopapilledema

    PubMed Central

    Carter, S B; Pistilli, M; Livingston, K G; Gold, D R; Volpe, N J; Shindler, K S; Liu, G T; Tamhankar, M A

    2014-01-01

    Purpose To determine the sensitivity and specificity of orbital ultrasonography in distinguishing papilledema from pseudopapilledema in adult patients. Methods The records of all adult patients referred to the neuro-ophthalmology service who underwent orbital ultrasonography for the evaluation of suspected papilledema were reviewed. The details of history, ophthalmologic examination, and results of ancillary testing including orbital ultrasonography, MRI, and lumbar puncture were recorded. Results of orbital ultrasonography were correlated with the final diagnosis of papilledema or pseudopapilledema on the basis of the clinical impression of the neuro-ophthalmologist. Ultrasound was considered positive when the optic nerve sheath diameter was ≥3.3 mm along with a positive 30° test. Results The sensitivity of orbital ultrasonography for detection of papilledema was 90% (CI: 80.2–99.3%) and the specificity in detecting pseudopapilledema was 79% (CI: 67.7–90.7%). Conclusions Orbital ultrasonography is a rapid and noninvasive test that is highly sensitive, but less specific in differentiating papilledema from pseudopapilledema in adult patients, and can be useful in guiding further management of patients in whom the diagnosis is initially uncertain. PMID:25190532

  5. Breast ultrasonography: state of the art.

    PubMed

    Hooley, Regina J; Scoutt, Leslie M; Philpotts, Liane E

    2013-09-01

    Ultrasonography (US) is an indispensable tool in breast imaging and is complementary to both mammography and magnetic resonance (MR) imaging of the breast. Advances in US technology allow confident characterization of not only benign cysts but also benign and malignant solid masses. Knowledge and understanding of current and emerging US technology, along with the application of meticulous scanning technique, is imperative for image optimization and diagnosis. The ability to synthesize breast US findings with multiple imaging modalities and clinical information is also necessary to ensure the best patient care. US is routinely used to guide breast biopsies and is also emerging as a supplemental screening tool in women with dense breasts and a negative mammogram. This review provides a summary of current state-of-the-art US technology, including elastography, and applications of US in clinical practice as an adjuvant technique to mammography, MR imaging, and the clinical breast examination. The use of breast US for screening, preoperative staging for breast cancer, and breast intervention will also be discussed.

  6. Endoscopic ultrasound description of liver segmentation and anatomy.

    PubMed

    Bhatia, Vikram; Hijioka, Susumu; Hara, Kazuo; Mizuno, Nobumasa; Imaoka, Hiroshi; Yamao, Kenji

    2014-05-01

    Endoscopic ultrasound (EUS) can demonstrate the detailed anatomy of the liver from the transgastric and transduodenal routes. Most of the liver segments can be imaged with EUS, except the right posterior segments. The intrahepatic vascular landmarks include the major hepatic veins, portal vein radicals, hepatic arterial branches, and the inferior vena cava, and the venosum and teres ligaments are other important intrahepatic landmarks. The liver hilum and gallbladder serve as useful surface landmarks. Deciphering liver segmentation and anatomy by EUS requires orienting the scan planes with these landmarkstructures, and is different from the static cross-sectional radiological images. Orientation during EUS requires appreciation of the numerous scan planes possible in real-time, and the direction of scanning from the stomach and duodenal bulb. We describe EUS imaging of the liver with a curved linear probe in a step-by-step approach, with the relevant anatomical details, potential applications, and pitfalls of this novel EUS application. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  7. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    PubMed

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate

  8. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    PubMed

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  9. Cardiovascular ultrasonography detection of embolic sources in trauma.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F; Poularas, John; Kostroglou, Andreas; Mandila, Christina; Panou, Fotios

    2018-06-01

    Venous thromboembolism (deep vein thrombosis and pulmonary embolism) and bone cement implantation syndrome are major sources of embolic events in trauma patients. In these patients, embolic events due to venous thromboembolism and bone cement implantation syndrome have been detected with cardiac and vascular ultrasonography in the emergency setting, during the perioperative period, and in the intensive care unit. This article discusses the ultrasonography modalities and imaging findings of embolic events related to venous thromboembolism and bone cement implantation syndrome. The aim is to present a short review with exceptional illustrations that can enable physicians to identify sources of emboli in trauma patients with cardiovascular ultrasonography. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    PubMed

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Comparison between coupled KZK-BHTE numerical simulations and scanned HIFU exposures in excised bovine liver

    NASA Astrophysics Data System (ADS)

    Andrew, Marilee A.; Brayman, Andrew A.; Kaczkowski, Peter J.; Kargl, Steven G.

    2004-05-01

    The use of moving high intensity focused ultrasound (HIFU) treatment protocols is of interest in achieving efficient formation of large-volume lesions in tissue. However, potentially unwanted thermal effects, such as prefocal heating, should be considered. A KZK acoustic model coupled with the BioHeat Transfer Equation has been extended to simulate multiple, moving scans in tissue. Simulation results are compared with experimental data collected over a range of exposure regimes for linear and concentric circular scans with a 3.5-MHz single-element transducer in ex vivo bovine liver. Of particular interest are investigating prefocal thermal buildup and ablating the central core of a circular pattern through conductive heating, that is without direct HIFU exposure. Qualitative agreement is observed between experimental and simulated data; limits of the predictive capability of the model in cavitation regimes will be discussed. [Support provided by the U.S. Army Medical Research Acquisition Activity through The University of Mississippi under terms of Agreement No. DAMD17-02-2-0014. The opinions expressed herein are those of the author(s) and do not necessarily reflect the views of U.S. Army Medical Research Acquisition Activity or The University of Mississippi.

  12. Vegetarian diet, food substitution, and nonalcoholic fatty liver

    PubMed Central

    Chiu, Tina H.; Lin, Ming-Nan; Pan, Wen-Harn; Chen, Yen-Ching; Lin, Chin-Lon

    2018-01-01

    Objectives: Vegetarian diets have been shown to improve insulin resistance and reduce body weight, but the effects on nonalcoholic fatty liver require further confirmation. We aim to investigate the association between vegetarian diets, major food groups, and nonalcoholic fatty liver, and to compare the degree of liver fibrosis between vegetarians and nonvegetarians in those with fatty liver. Materials and Methods: We analyzed cross-sectional data from the Tzu Chi Health Study which included 2127 nonvegetarians and 1273 vegetarians who did not smoke or habitually drink alcohol and had no hepatitis B or hepatitis C. Fatty liver and liver fibrosis were determined using ultrasonography and the nonalcoholic fatty liver disease fibrosis score, respectively. Diet was assessed through a validated food frequency questionnaire. Results: Vegetarian diets were associated with lower odds of fatty liver (odds ratio = 0.79, 95% confidence interval: 0.68–0.91) after adjusting for age, gender, education, history of smoking and alcohol drinking. Adjustment for body mass index (BMI) attenuated the protective association. Vegetarians had less severe fibrosis than nonvegetarians. Replacing a serving of soy with a serving of meat or fish was associated with 12%–13% increased risk, and replacing a serving of whole grains with a serving of refined grains, fruits, and fruit juice was associated with 3%–12% increased the risk of fatty liver. Conclusion: Vegetarian diets, replacing meat and fish with soy, and replacing refined carbohydrates with whole grains, may be inversely associated with nonalcoholic fatty liver related to BMI. PMID:29875591

  13. External ultrasonography of the neck does not add diagnostic value to integrated positron emission tomography-computed tomography (PET-CT) scanning in the diagnosis of cervical lymph node metastases in patients with esophageal carcinoma.

    PubMed

    Blom, R L G M; Vliegen, R F A; Schreurs, W M J; Belgers, H J; Stohr, I; Oostenbrug, L E; Sosef, M N

    2012-08-01

    One of the objectives of preoperative imaging in esophageal cancer patients is the detection of cervical lymph node metastases. Traditionally, external ultrasonography of the neck has been combined with computed tomography (CT) in order to improve the detection of cervical metastases. In general, integrated positron emission tomography-computed tomography (PET-CT) has been shown to be superior to CT or PET regarding staging and therefore may limit the role of external ultrasonography of the neck. The objective of this study was to determine the additional value of external ultrasonography of the neck to PET-CT. This study included all patients referred our center for treatment of esophageal carcinoma. Diagnostic staging was performed to determine treatment plan. Cervical lymph nodes were evaluated by external ultrasonography of the neck and PET-CT. In case of suspect lymph nodes on external ultrasonography or PET-CT, fine needle aspiration (FNA) was performed. Between 2008 and 2010, 170 out of 195 referred patients underwent both external ultrasonography of the neck and PET-CT. Of all patients, 84% were diagnosed with a tumor at or below the distal esophagus. In 140 of 170 patients, the cervical region was not suspect; no FNA was performed. Seven out of 170 patients had suspect nodes on both PET-CT and external ultrasonography. Five out of seven patients had cytologically confirmed malignant lymph nodes, one of seven had benign nodes, in one patient FNA was not performed; exclusion from esophagectomy was based on intra-abdominal metastases. In one out of 170 patients, PET-CT showed suspect nodes combined with a negative external ultrasonography; cytology of these nodes was benign. Twenty-two out of 170 patients had a negative PET-CT with suspect nodes on external ultrasonography. In 18 of 22 patients, cervical lymph nodes were cytologically confirmed benign; in four patients, FNA was not possible or inconclusive. At a median postoperative follow-up of 15 months

  14. Ultrasonography of the hand, wrist, and elbow.

    PubMed

    Bodor, Marko; Fullerton, Brad

    2010-08-01

    High-frequency diagnostic ultrasonography of the hand, wrist and elbow has significant potential to improve the quality of diagnosis and care provided by neuromuscular and musculoskeletal specialists. In patients referred for weakness, pain and numbness of the hand, wrist or elbow, diagnostic ultrasonography can be an adjunct to electrodiagnosis and help in identifying ruptured tendons and treating conditions such as carpal tunnel syndrome or trigger finger. Use of a small high-frequency (>10-15 MHz) transducer, an instrument with a blunt pointed tip to enhance sonopalpation and a model of the hand, wrist and elbow is advised to enhance visualization of small anatomical structures and complex bony contours. A range of conditions, including tendon and ligament ruptures, trigger finger, de Quervain tenosynovitis, intersection syndrome, lateral epicondylitis, and osteoarthritis, is described along with detailed ultrasonography-guided injection techniques for carpal tunnel syndrome and trigger finger. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Chest ultrasonography in health surveillance of asbestos-related lung diseases.

    PubMed

    Smargiassi, Andrea; Pasciuto, Giuliana; Pedicelli, Ilaria; Lo Greco, Erminia; Calvello, Mariarosaria; Inchingolo, Riccardo; Schifino, Gioacchino; Capoluongo, Patrizio; Patriciello, Pasquale; Manno, Maurizio; Cirillo, Alfonso; Corbo, Giuseppe Maria; Soldati, Gino; Iavicoli, Ivo

    2017-06-01

    Exposure to asbestos fibers can lead to different lung diseases, such as pleural thickening and effusion, asbestosis, mesothelioma, and lung cancer. These diseases are expected to peak in the next few years. The aim of the study was to validate ultrasonography (US) as a diagnostic tool in the management of lung diseases in subjects with a history of occupational exposure to asbestos. Fifty-nine retired male workers previously exposed to asbestos were enrolled in the study. Chest US was performed in all the subjects. The US operator was blinded to earlier performed computed tomography (CT) scan reports and images. The sonographic pathological findings were pleural thickening (with or without calcifications), peripheral lung consolidation, and focal sonographic interstitial syndrome and diffuse pneumogenic sonographic interstitial syndrome (pulmonary asbestosis). Significant US findings were recorded, stored, and subsequently compared with CT scans. With some patients falling into more than one category, on CT scan, pleural thickening was reported in 33 cases (56%, 26 with calcifications), focal interstitial peripheral alterations in 23 (39%), asbestosis in 6 (10%), and peripheral lung consolidation in 13 cases (22%). Comparing each pathological condition to CT scan reports, US findings had high levels of sensitivity, specificity, positive, and negative predictive values. US did not prove effective for the detection of central lung nodules or diaphragmatic pleural thickenings. Chest US was considered to be the best technique to detect minimal pleural effusions (six subjects, 10%). Chest US might be considered an additional tool to follow up subjects occupationally exposed to asbestos who have already undergone CT scan examination and whose pathology is detectable by US as well.

  16. A report on an acute, in-hours, outpatient review clinic with ultrasonography facilities for the early evaluation of general surgical patients.

    PubMed

    Pidgeon, T E; Shariff, U; Devine, F; Menon, V

    2016-09-01

    Introduction In 2013 our hospital introduced an in-hours, consultant-led, outpatient acute surgical clinic (ASC) for emergency general surgical patients. In 2014 this clinic was equipped with a dedicated ultrasonography service. This prospective cohort study evaluated this service before and after the introduction of ultrasonography facilities. Methods Data were recorded prospectively for all patients attending the clinic during 2013 and 2014. The primary outcome was patient destination (whether there was follow-up/admission) after clinic attendance. Results The ASC reviewed patients with a wide age range and array of general surgical complaints. In 2013, 186 patients attended the ASC. After the introduction of the ultrasonography service in 2014, 304 patients attended. In 2014, there was a reduction in the proportion of patients admitted to hospital from the clinic (18.3% vs 8.9%, p=0.002). However, the proportion of patients discharged after ASC review remained comparable with 2013 (30.1% in 2013 vs 38.8% in 2014, p=0.051). The proportion of patients undergoing computed tomography (CT) scans also fell (14.0% vs 4.9%, p<0.001). Conclusions The ASC assessed a wide array of general surgical complaints. Only a small proportion required hospital admission. The introduction of an ultrasonography service was associated with a further reduction in admission rates and computed tomography.

  17. Rapidly progressing malignant insulinoma presented with multiple liver metastases: a case report.

    PubMed

    Erdogan, Askin; Askin, Erdogan; Kose, Fatih; Fatih, Kose; Akkaya, Hampar; Hampar, Akkaya; Bascil Tutuncu, Neslihan; Tutuncu, Neslihan Bascil; Ozyilkan, Ozgur; Ozgur, Ozyilkan

    2010-12-01

    A 51-year-old female was admitted to emergency unit with sudden loss of consciousness. Her blood glucose level from fingertip was 33 mg/dl, and insulin level was 55 (normal range, 4-17 IU). Abdominal ultrasonography revealed pancreatic mass with diffuse liver metastases. Biopsy of liver metastases showed differentiated neuroendocrine carcinoma. Diazoxide and chemotherapy stabilized her glucose level for more than 4 months. However, the disease showed progression, and death occurred 8 months later. In conclusion, this case may suggest that biologic behavior may differ from histological behavior in insulinoma and platin-based systemic chemotherapy may provide some benefit in patients those who had diazoxide- and octreotide-resistant tumors.

  18. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    NASA Astrophysics Data System (ADS)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  19. External Validation of Fatty Liver Index for Identifying Ultrasonographic Fatty Liver in a Large-Scale Cross-Sectional Study in Taiwan

    PubMed Central

    Fang, Kuan-Chieh; Wang, Yuan-Chen; Huo, Teh-Ia; Huang, Yi-Hsiang; Yang, Hwai-I; Su, Chien-Wei; Lin, Han-Chieh; Lee, Fa-Yauh; Wu, Jaw-Ching; Lee, Shou-Dong

    2015-01-01

    Background and Aims The fatty liver index (FLI) is an algorithm involving the waist circumference, body mass index, and serum levels of triglyceride and gamma-glutamyl transferase to identify fatty liver. Although some studies have attempted to validate the FLI, few studies have been conducted for external validation among Asians. We attempted to validate FLI to predict ultrasonographic fatty liver in Taiwanese subjects. Methods We enrolled consecutive subjects who received health check-up services at the Taipei Veterans General Hospital from 2002 to 2009. Ultrasonography was applied to diagnose fatty liver. The ability of the FLI to detect ultrasonographic fatty liver was assessed by analyzing the area under the receiver operating characteristic (AUROC) curve. Results Among the 29,797 subjects enrolled in this study, fatty liver was diagnosed in 44.5% of the population. Subjects with ultrasonographic fatty liver had a significantly higher FLI than those without fatty liver by multivariate analysis (odds ratio 1.045; 95% confidence interval, CI 1.044–1.047, p< 0.001). Moreover, FLI had the best discriminative ability to identify patients with ultrasonographic fatty liver (AUROC: 0.827, 95% confidence interval, 0.822–0.831). An FLI < 25 (negative likelihood ratio (LR−) 0.32) for males and <10 (LR− 0.26) for females rule out ultrasonographic fatty liver. Moreover, an FLI ≥ 35 (positive likelihood ratio (LR+) 3.12) for males and ≥ 20 (LR+ 4.43) for females rule in ultrasonographic fatty liver. Conclusions FLI could accurately identify ultrasonographic fatty liver in a large-scale population in Taiwan but with lower cut-off value than the Western population. Meanwhile the cut-off value was lower in females than in males. PMID:25781622

  20. [Analysis of eye ultrasonography in patients with trinitrotoluene cataract].

    PubMed

    Huang, Dongmei; Zhu, Linping; Yang, Jinping; Wu, Donping

    2015-04-01

    To evaluate the diagnostic value of ultrasonography for trinitrotoluene (TNT) cataract. The morphology and internal echoes of 90 lenses of 45 TNT cataract patients and 120 lenses of 60 healthy adults were observed and compared using ultrasonography and slit lamp, and the hemodynamic parameters of the post-ophthalmic artery were also measured. The findings of the slit-lamp microscope were regarded as diagnostic criteria, and the sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were calculated. The sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were 93.33%, 100.00%, and 97.14%, respectively; the positive and negative predictive values were 100% and 95.23%, respectively; the positive and negative likelihood ratios were 93.33 and 0.67, especuvey. With the progression TNT cataract, utrasonography showed that the lenses demonstrated morphological changes (spindle-shaped, spherical, and discoid morphologies), and the arc echoes of the posterior capsule were thickened and enhanced. The TNT cataract patients showed significantly lower peak systolic velocity and end-diastolic velocity of the ophthalmic artery (OA) and central retinal artery (P<0.01) and a significantly higher resistance index (P<0.05) than the healthy adults. The sensitivity of ultrasonography in the diagnosis of TNT cataract is similar to that of slit lamp. Ultrasonography can demonstrate objectively the shape, range, and degree of lens opacity in an efficient manner, which is conducive to the diagnosis and staging of TNT cataract by slit lamp, and can also provide hemodynamic information of the OA, thus providing new ideas for clinical physicians in evaluating the disease and clinical efficacy as well as exploring therapies.

  1. Disappearance of multiple hyperechoic liver nodules in sporadic porphyria cutanea tarda after treatment with ledipasvir/sofosbuvir for hepatitis C.

    PubMed

    Takata, Kazuhide; Shakado, Satoshi; Sakamoto, Keiko; Fukuda, Hiromi; Yamauchi, Ryo; Fukuda, Sho; Kunimoto, Hideo; Umeda, Kaoru; Tanaka, Takashi; Yokoyama, Keiji; Morihara, Daisuke; Takeyama, Yasuaki; Irie, Makoto; Sakisaka, Shotaro

    2017-10-01

    Ultrasonography in a 60-year-old man with chronic hepatitis C (CHC) demonstrated multiple hyperechoic nodules. Radiological investigations did not reveal any signs of malignancy. However, magnetic resonance chemical shift imaging showed multiple focal fatty changes in the liver. Urinary levels of uroporphyrin and coproporphyrin were elevated, and we made a diagnosis of porphyria cutanea tarda. Direct-acting antivirals, ledipasvir/sofosbuvir, were initiated for CHC, which led to sustained viral response, resolution of the liver nodules, and normalization of urinary porphyrin. Hepatitis C virus infection can cause porphyria cutanea tarda with multiple hyperechoic liver nodules, which might be cured by direct-acting antivirals.

  2. Imaging of non alcoholic fatty liver disease: A road less travelled.

    PubMed

    Singh, Divya; Das, Chandan J; Baruah, Manas P

    2013-11-01

    Non alcoholic fatty liver disease (NAFLD) is a spectrum that includes simple steatosis, nonalcoholic steatohepatitis and cirrhosis. It is increasingly emerging as a cause of elevated liver enzymes, cryptogenic cirrhosis and hepatocellular carcinoma. The morbidity and mortality related to NAFLD is expected to rise with the upsurge of obesity and type 2 diabetes mellitus. The need of the hour is to devise techniques to estimate and then accurately follow-up hepatic fat content in patients with NAFLD. There are lots of imaging modalities in the radiological armamentarium, namely, ultrasonography with the extra edge of elastography, computed tomography, and magnetic resonance imaging with chemical shift imaging and spectroscopy to provide an estimation of hepatic fat content.

  3. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  4. Diagnostic accuracy of transabdominal ultrasonography for gallbladder polyps: systematic review.

    PubMed

    Martin, Erin; Gill, Richdeep; Debru, Estifanos

    2018-06-01

    Previous research has shown variable but generally poor accuracy of transabdominal ultrasonography in the diagnosis of gallbladder polyps. We performed a systematic review of the literature with the aim of helping surgeons interpret and apply these findings in the preoperative assessment and counselling of their patients. We searched PubMed, MEDLINE and the Cochrane database using the keywords "gallbladder," "polyp," "ultrasound," "pathology" and "diagnosis" for English-language articles published after 1990 with the full-text article available through our institutional subscriptions. Polyps were defined as immobile features that on transabdominal ultrasonography appear to arise from the mucosa and that lack an acoustic shadow, and pseudopolyps were defined as features such as inflammation, hyperplasia, cholesterolosis and adenomyomatosis that convey no risk of malignant transformation. The search returned 1816 articles, which were narrowed down to 14 primary sources involving 15 497 (range 23-13 703) patients who had preoperative transabdominal ultrasonography, underwent cholecystectomy and had postoperative pathology results available. Among the 1259 patients in whom a gallbladder polyp was diagnosed on ultrasonography, 188 polyps were confirmed as true polyps on pathologic examination, and 81 of these were found to be malignant. Of the 14 238 patients for whom a polyp was not seen on ultrasonography, 38 had a true polyp on pathologic examination, none of which were malignant. For true gallbladder polyps, transabdominal ultrasonography had a sensitivity of 83.1%, specificity of 96.3%, positive predictive value of 14.9% (7.0% for malignant polyps) and negative predictive value of 99.7%. Transabdominal ultrasonography has a high false-positive rate (85.1%) for the diagnosis of gallbladder polyps. Further study of alternative imaging modalities and reevaluation of existing management guidelines are warranted.

  5. Automatic liver volume segmentation and fibrosis classification

    NASA Astrophysics Data System (ADS)

    Bal, Evgeny; Klang, Eyal; Amitai, Michal; Greenspan, Hayit

    2018-02-01

    In this work, we present an automatic method for liver segmentation and fibrosis classification in liver computed-tomography (CT) portal phase scans. The input is a full abdomen CT scan with an unknown number of slices, and the output is a liver volume segmentation mask and a fibrosis grade. A multi-stage analysis scheme is applied to each scan, including: volume segmentation, texture features extraction and SVM based classification. Data contains portal phase CT examinations from 80 patients, taken with different scanners. Each examination has a matching Fibroscan grade. The dataset was subdivided into two groups: first group contains healthy cases and mild fibrosis, second group contains moderate fibrosis, severe fibrosis and cirrhosis. Using our automated algorithm, we achieved an average dice index of 0.93 ± 0.05 for segmentation and a sensitivity of 0.92 and specificity of 0.81for classification. To the best of our knowledge, this is a first end to end automatic framework for liver fibrosis classification; an approach that, once validated, can have a great potential value in the clinic.

  6. Xeroradiography and ultrasonography in the evaluation of a penile injury.

    PubMed

    Oesterling, J E; Bromberg, W D; Albertsen, P C

    1986-04-01

    A 34-year-old white man presented with severe penile cellulitis following injection of epoxy glue into the shaft of the penis. Preoperative xeroradiography and ultrasonography localized the hardened masses of glue to the left corpus cavernosum and subcutaneous tissues. Under the guidance of intraoperative ultrasonography this foreign material was removed surgically. Postoperatively, the cellulitis resolved promptly and xeroradiography demonstrated no residual fragments. Although various modalities, including computerized tomography and roentgenography, are available to detect foreign bodies in soft tissues, xeroradiography and ultrasonography are ideally suited for use in the male external genitalia.

  7. The impact of weight changes on nonalcoholic Fatty liver disease in adult men with normal weight.

    PubMed

    Cho, Ji-Young; Chung, Tae-Heum; Lim, Kyoung-Mo; Park, Hee-Jin; Jang, Jung-Mi

    2014-09-01

    Although it is known that losing weight has an effect on the treatment of non-alcoholic fatty liver disease, the studies that show how losing weight affects the non-alcoholic fatty liver disease for the normal weight male adults are limited so far. In this study, we set body mass index as criteria and investigated how the weight changes for 4 years makes an impact on the risk of non-alcoholic fatty liver disease for the male adults who have the normal body mass index. From January to December of 2004, among the normal weight male adults who had general check-up at the Health Promotion Center of Ulsan University Hospital, 180 people (average age, 47.4 ± 4.61 years) who were diagnosed with fatty liver through abdominal ultrasonography were included in this study and were observed according to the variety of data and ultrasonography after 4 years (2008). People who had a history of drinking more than 140 g of alcohol per week or who had a past medical history were excluded from the analysis. The weight change of subjects was calculated using the formula 'weight change = weight of 2008 (kg) - weight of 2004 (kg)' and classified into three groups, loss group (≤-3.0 kg), stable group (-2.9 to 2.9 kg), and gain group (≥3.0 kg). The odds for disappearance of non-alcoholic fatty liver disease in those three different groups were compared. Among 180 subjects, compared with stable group (67.2%, 121 subjects), loss group (11.7%, 21 subjects) showed 18.37-fold increase in the odds of disappearance of non-alcoholic fatty liver disease (95% confidence interval [CI], 4.34 to 77.80) and gain group (21.1%, 38 subjects) showed 0.28-fold decrease in the odds of disappearance of non-alcoholic fatty liver disease (95% CI, 0.10 to 0.83). Even for the normal weight people, losing weight has an effect on the improvement of non-alcoholic fatty liver disease.

  8. Survival Outcomes for Patients With Indeterminate 18FDG-PET Scan for Extrahepatic Disease Before Liver Resection for Metastatic Colorectal Cancer: A Retrospective Cohort Study Using a Prospectively Maintained Database to Analyze Survival Outcomes for Patients With Indeterminate Extrahepatic Disease on 18FDG-PET Scan Before Liver Resection for Metastatic Colorectal Cancer.

    PubMed

    Wong, Geoffrey Yuet Mun; Kumar, Rajiv; Beeke, Carol; Ullah, Shahid; Chen, John; Karapetis, Christos; Price, Timothy; Padbury, Rob

    2018-05-01

    The aim of this study was to evaluate overall survival (OS) and cancer recurrence for patients with indeterminate positron emission tomography (PET) scan for extrahepatic disease (EHD) before liver resection (LR) for colorectal liver metastases (CLMs). Indeterminate EHD as determined by PET imaging indicates a probability of extrahepatic malignancy and potentially excludes patients from undergoing LR for CLM. In a retrospective analysis of prospectively collected data from February 2006 to December 2014, OS for patients with indeterminate EHD on FDG-PET scan before LR for CLM was performed using standard survival analysis methods, including Kaplan-Meier estimator and Cox proportional hazard models for multivariate analyses. Postoperative imaging was used as reference to evaluate the association between indeterminate EHD and recurrence. Of 267 patients with PET scans before LR, 197 patients had no EHD and 70 patients had indeterminate EHD. Median follow-up was 33 months. The estimated 5-year OS was 60.8% versus 59.4% for indeterminate and absent EHD, respectively (P = 0.625). Disease-free survival was comparable between both groups (P = 0.975) and overall recurrence was 57.1% and 59.5% for indeterminate and absent EHD, respectively (P = 0.742). About 16.9% of recurrence was associated with the site of indeterminate EHD, with 80% of associated recurrence occurring in the thorax. The site of indeterminate EHD appears to have a predictive value for recurrence, with indeterminate EHD in the thorax having a higher probability of malignancy. The evidence in this report supports the critical evaluation of PET scan results and that patients are not denied potential curative LR unless the evidence for unresectable EHD is certain.

  9. Computed tomography findings in liver fibrosis and cirrhosis.

    PubMed

    Huber, A; Ebner, L; Montani, M; Semmo, N; Roy Choudhury, K; Heverhagen, J; Christe, A

    2014-02-19

    Computed tomography (CT) is inferior to the fibroscan and laboratory testing in the noninvasive diagnosis of liver fibrosis. On the other hand, CT is a frequently used diagnostic tool in modern medicine. The auxiliary finding of clinically occult liver fibrosis in CT scans could result in an earlier diagnosis. The aim of this study was to analyse quantifiable direct signs of liver remodelling in CT scans to depict liver fibrosis in a precirrhotic stage. Retrospective review of 148 abdominal CT scans (80 liver cirrhosis, 35 precirrhotic fibrosis and 33 control patients). Fibrosis and cirrhosis were histologically proven. The diameters of the three main hepatic veins were measured 1-2 cm before their aperture into the inferior caval vein. The width of the caudate and the right hepatic lobe were divided, and measured horizontally at the level of the first bifurcation of the right portal vein in axial planes (caudate-right-lobe ratio). A combination of both (sum of liver vein diameters divided by the caudate-right lobe ratio) was defined as the ld/crl ratio. These metrics were analysed for the detection of liver fibrosis and cirrhosis. An ld/crl-r <24 showed a sensitivity of 83% and a specificity of 76% for precirrhotic liver fibrosis. Liver cirrhosis could be detected with a sensitivity of 88% and a specificity of 82% if ld/crl-r <20. An ld/crl-r <24 justifies laboratory testing and a fibroscan. This could bring forward the diagnosis and patients would profit from early treatment in a potentially reversible stage of disease.

  10. Progression of liver fibrosis is associated with non‐liver‐related mortality in patients with nonalcoholic fatty liver disease

    PubMed Central

    Kumada, Takashi; Toyoda, Hidenori; Mizuno, Kazuyuki; Sone, Yasuhiro; Akita, Tomoyuki; Tanaka, Junko

    2017-01-01

    In patients with nonalcoholic fatty liver disease (NAFLD), prognosis and outcome, especially non‐liver‐related mortality, remain incompletely elucidated. We clarified the mortality from all causes in patients with NAFLD. A total of 4,073 patients with NAFLD diagnosed by ultrasonography were enrolled. We investigated the causes of death and analyzed the mortality from non‐liver‐related diseases according to the degrees of steatosis and fibrosis using the competing risk method. We used the NAFLD fibrosis score (NFS) to assess fibrosis severity and the ultrasonography fatty liver score to evaluate steatosis severity. The numbers of patients with NFS indicating low, intermediate, and high probabilities of advanced fibrosis were 2,451 (60.2%), 1,462 (35.9%), and 160 (3.9%), respectively. Of the 4,073 patients, 179 died during follow‐up, but only nine deaths were due to liver‐related diseases. Of the remaining 170 patients who died due to non‐liver‐related diseases, 83 (48.8%), 42 (24.7%), and 45 (26.5%) patients died due to malignancies, cerebrovascular and cardiovascular diseases, and benign diseases (excluding cerebrovascular and cardiovascular diseases), respectively. Multivariate analysis showed that the intermediate and high NFS groups were independently associated with each disease category: hazard ratio (HR) 2.163 (95% confidence interval [CI], 1.354‐3.457) and HR 4.814 (95% CI, 2.323‐9.977) for malignancies; HR 2.265 (95% CI, 1.141‐4.497) and HR 8.482 (95% CI, 3.558‐20.220) for cerebrovascular and cardiovascular diseases; and HR 3.216 (95% CI, 1.641‐6.303) and HR 5.558 (95% CI, 1.923‐16.070) for benign diseases, respectively. Conversely, the status of steatosis was not associated with risk of mortality in multivariate analysis. Conclusion: Progression of liver fibrosis severity was associated with mortality from various non‐liver‐related causes in patients with NAFLD. (Hepatology Communications 2017;1:928–945) PMID:29404500

  11. Point-of-care ultrasonography by pediatric emergency physicians. Policy statement.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Point-of-care ultrasonography is increasingly being used to facilitate accurate and timely diagnoses and to guide procedures. It is important for pediatric emergency physicians caring for patients in the emergency department to receive adequate and continued point-of-care ultrasonography training for those indications used in their practice setting. Emergency departments should have credentialing and quality assurance programs. Pediatric emergency medicine fellowships should provide appropriate training to physician trainees. Hospitals should provide privileges to physicians who demonstrate competency in point-of-care ultrasonography. Ongoing research will provide the necessary measures to define the optimal training and competency assessment standards. Requirements for credentialing and hospital privileges will vary and will be specific to individual departments and hospitals. As more physicians are trained and more research is completed, there should be one national standard for credentialing and privileging in point-of-care ultrasonography for pediatric emergency physicians.

  12. Assessment of tumor vascularization with functional computed tomography perfusion imaging in patients with cirrhotic liver disease.

    PubMed

    Li, Jin-Ping; Zhao, De-Li; Jiang, Hui-Jie; Huang, Ya-Hua; Li, Da-Qing; Wan, Yong; Liu, Xin-Ding; Wang, Jin-E

    2011-02-01

    Hepatocellular carcinoma (HCC) is a common malignant tumor in China, and early diagnosis is critical for patient outcome. In patients with HCC, it is mostly based on liver cirrhosis, developing from benign regenerative nodules and dysplastic nodules to HCC lesions, and a better understanding of its vascular supply and the hemodynamic changes may lead to early tumor detection. Angiogenesis is essential for the growth of primary and metastatic tumors due to changes in vascular perfusion, blood volume and permeability. These hemodynamic and physiological properties can be measured serially using functional computed tomography perfusion (CTP) imaging and can be used to assess the growth of HCC. This study aimed to clarify the physiological characteristics of tumor angiogenesis in cirrhotic liver disease by this fast imaging method. CTP was performed in 30 volunteers without liver disease (control subjects) and 49 patients with liver disease (experimental subjects: 27 with HCC and 22 with cirrhosis). All subjects were also evaluated by physical examination, laboratory screening and Doppler ultrasonography of the liver. The diagnosis of HCC was made according to the EASL criteria. All patients underwent contrast-enhanced ultrasonography, pre- and post-contrast triple-phase CT and CTP study. A mathematical deconvolution model was applied to provide hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT), permeability of capillary vessel surface (PS), hepatic arterial index (HAI), hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP) data. The Mann-Whitney U test was used to determine differences in perfusion parameters between the background cirrhotic liver parenchyma and HCC and between the cirrhotic liver parenchyma with HCC and that without HCC. In normal liver, the HAP/HVP ratio was about 1/4. HCC had significantly higher HAP and HAI and lower HPP than background liver parenchyma adjacent to the HCC. The value of HBF at the tumor

  13. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    PubMed

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs < 50 cm/s throughout the graft, and Vr > 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  14. Reliable and valid assessment of point-of-care ultrasonography.

    PubMed

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt; Henriksen, Birthe Merete; Hillingsø, Jens Georg; Konge, Lars; Jensen, Morten Lind; Ringsted, Charlotte

    2015-02-01

    To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. POC US is increasingly used by clinicians and is an essential part of the management of acute surgical conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different surgical patient cases in a controlled set-up. All ultrasound examinations were video-recorded and assessed by 2 blinded radiologists using OSAUS. Reliability was examined using generalizability theory. Construct validity was examined by comparing performance scores between the groups and by correlating physicians' OSAUS scores with diagnostic accuracy. The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores between the novice group (17.0; SD 8.4) and the intermediate group (30.0; SD 10.1), P = 0.007, as well as between the intermediate group and the expert group (72.9; SD 4.4), P = 0.04, and by a high correlation between OSAUS scores and diagnostic accuracy (Spearman ρ correlation coefficient = 0.76; P < 0.001). This study demonstrates high reliability as well as evidence of construct validity of the OSAUS scale for assessment of POC US competence. Hence, the OSAUS scale may be suitable for both in-training as well as end-of-training assessment.

  15. [Role of FibroScan in liver fibrosis evaluation in patients with chronic hepatitis B virus infection and related influencing factors].

    PubMed

    Xie, Q X; Xu, N; Jiang, X P; Zhang, Y F; Zhang, Z H; Li, J B; Hu, X Y; Li, X

    2016-09-20

    Objective: To investigate the role of FibroScan(FS)in liver fibrosis evaluation in patients with chronic hepatitis B virus(HBV)infection and related influencing factors. Methods: A total of 313 patients with chronic HBV infection were enrolled, and liver tissue was obtained through ultrasound-guided"1-second fast tissue cutting". The liver stiffness measurement(LSM)was determined by FS, serum HBeAg and liver function were measured, and the patients' demographic data were recorded. The t -test was used for comparison of normally distributed data between groups, and the Mann-Whitney U test was used for comparison of non-normally distributed data between groups; the Spearman or Pearson correlation coefficient was used for correlation analysis; the ROC curve and AUC were used to evaluate the efficiency of FS in the diagnosis of liver fibrosis ≥S2. Results: LSM was positively correlated with liver inflammation grade and fibrosis stage( r = 0.428 and 0.402 in HBeAg-positive group and r = 0.296 and 0.283 in HBeAg-negative group, all P < 0.001). The correlation of LSM with sex, age, alanine aminotransferase(ALT)level, and total bilirubin(TBil)was affected by HBeAg status and ALT level, and LSM was only positively correlated with TBil in HBeAg-negative group( r = 0.298, P < 0.001). In patients with ALT ≥2×upper limit of normal(ULN), FS had a low efficiency in the diagnosis of liver fibrosis ≥S2(AUC < 0.75, P > 0.05), regardless of their HBeAg status. The cut-off values of FS in the diagnosis of liver fibrosis ≥S2 varied with ALT level and HBeAg status, and in the ALT <1×ULN and 1-2×ULN groups, the cut-off values of FS in the diagnosis of liver fibrosis ≥S2 in patients with positive and negative HBeAg were 5.85 kPa/7.3 kPa and 6.35 kPa/8.5 kPa, respectively. In the patients with positive HBeAg in ALT < 2×ULN group, LSM was positively correlated with age( r = 0.278, P = 0.014). FS had relatively high diagnostic efficiency in patients aged > 30 years(AUC = 0

  16. Study of curcumin on microvasculature characteristic in diabetic rat's liver as revealed by vascular corrosion cast/scanning electron microscope (SEM) technique.

    PubMed

    Khimmaktong, Wipapan; Petpiboolthai, Hattaya; Panyarachun, Busaba; Anupunpisit, Vipavee

    2012-05-01

    To investigate the effect of curcumin on the structural change ofmicrovasculature in STZ-induced diabetic rat' liver. Diabetic rats were induced by streptozotocin (60 mg/kg BW). Male rats were divided into thre groups, control (C), diabetic (DM) and diabetic rats treated with curcumin (DMC) (200 mg/kg BW). After 8 weeks o experiments, blood vessels of rat's liver were studied under conventional light microscope (LM) and vascular corrosion cas technique with scanning electron microscope (SEM). LM observation demonstrated that there were pathology and destruction of liver tissues and microvasculature in diabetic animals. The sinusoids around central veins were dilated and filled with red blood cells. There was an accumulation of lipid droplets in the cytoplasm of hepatocytes and hepatocyte nuclei showed pathological sign of pyknosis. Moreover, the inflammation change of liver tissues revealed the infiltration of lymphocytes and increasing of collagen deposition in the area of portal triad. In curcumin-treated rats, the distinguished recovery of liver tissues showed regained normal pattern of central veins, sinusoids, hepatocytes and portal triad, when compared with liver tissues of control group. By using vascular corrosion casting with SEM, the liver blood vessels of DM group revealed higher and expanded sizes, compared with control group; proximal parts of portal veins (C = 577.75 +/- 126.23, DM = 892 +/- 35.79, DMC = 469.5 +/- 8553 microm), distal parts of portal veins (C = 76.72 +/- 1.48, DM = 200 +/- 31.05, DMC = 76.38 +/- 2.98 microm) and venules (C = 27.03 +/- 0.55, DM = 45.15 +/- 5.03, DMC = 28.38 +/- 3.67 microm) and corresponding to increased blood volumes compared with control group; proximal parts of portal veins (C = 20.8 +/- 1.28, DM = 62.2 +/- 3.39, DMC = 14.9 +/- 0.67 microm3), distal parts of portal veins (C = 0.46 +/- 0.03, DM = 3.81 +/- 0.18, DMC = 0.41 +/- 0.05 microm3) and venules (C = 0.05 +/- 0.05, DM = 0.24 +/- 0.013, DMC = 0.05 +/- 0

  17. Clinical utility of colour flow Doppler ultrasonography in planning anterolateral thigh flap harvest.

    PubMed

    Patel, Rajan S; Higgins, Kevin M; Enepekides, Danny J; Hamilton, Paul A

    2010-10-01

    The anatomic variability of cutaneous perforators contributes to the technical challenges of anterolateral thigh (ALT) free flap harvest. The objective of this study was to assess the accuracy and clinical utility of preoperative colour flow Doppler (CFD) ultrasonography in evaluating planned ALT flap donor sites. A prospective study of the infrainguinal vasculature (profunda femoris and lateral circumflex femoral arteries) in 16 consecutive patients scheduled for ALT free flap transfer for reconstruction of head and neck surgical defects was undertaken. All patients underwent CFD ultrasonography. The location of perforators and the thigh thickness determined by CFD ultrasonography were correlated with the actual intraoperative findings using a scatter plot and paired t-test. Two patients were diagnosed with bilateral silent infrainguinal claudication, which precluded safe use of the ALT donor site. In two other patients, the planned ALT donor site ipsilateral to the defect was not used because of silent infrainguinal claudication diagnosed by CFD ultrasonography. In the 14 patients who underwent ALT flap harvest, CFD ultrasonography identified 48 perforators, which coincided with 43 actual perforators found intraoperatively. CFD ultrasonography demonstrated a statistically significant correlation with the actual perforator locations (Spearman coefficient .76; p = .55). Although CFD ultrasonography tended to underestimate flap thickness, there was a statistically significant correlation (Spearman coefficient .94; p ≤ .0001) with the actual flap thickness. CFD ultrasonography has clinical utility in facilitating decision making and planning ALT flap harvest.

  18. Stereological Analysis of Liver Biopsy Histology Sections as a Reference Standard for Validating Non-Invasive Liver Fat Fraction Measurements by MRI

    PubMed Central

    St. Pierre, Tim G.; House, Michael J.; Bangma, Sander J.; Pang, Wenjie; Bathgate, Andrew; Gan, Eng K.; Ayonrinde, Oyekoya T.; Bhathal, Prithi S.; Clouston, Andrew; Olynyk, John K.; Adams, Leon A.

    2016-01-01

    Background and Aims Validation of non-invasive methods of liver fat quantification requires a reference standard. However, using standard histopathology assessment of liver biopsies is problematical because of poor repeatability. We aimed to assess a stereological method of measuring volumetric liver fat fraction (VLFF) in liver biopsies and to use the method to validate a magnetic resonance imaging method for measurement of VLFF. Methods VLFFs were measured in 59 subjects (1) by three independent analysts using a stereological point counting technique combined with the Delesse principle on liver biopsy histological sections and (2) by three independent analysts using the HepaFat-Scan® technique on magnetic resonance images of the liver. Bland Altman statistics and intraclass correlation (IC) were used to assess the repeatability of each method and the bias between the methods of liver fat fraction measurement. Results Inter-analyst repeatability coefficients for the stereology and HepaFat-Scan® methods were 8.2 (95% CI 7.7–8.8)% and 2.4 (95% CI 2.2–2.5)% VLFF respectively. IC coefficients were 0.86 (95% CI 0.69–0.93) and 0.990 (95% CI 0.985–0.994) respectively. Small biases (≤3.4%) were observable between two pairs of analysts using stereology while no significant biases were observable between any of the three pairs of analysts using HepaFat-Scan®. A bias of 1.4±0.5% VLFF was observed between the HepaFat-Scan® method and the stereological method. Conclusions Repeatability of the stereological method is superior to the previously reported performance of assessment of hepatic steatosis by histopathologists and is a suitable reference standard for validating non-invasive methods of measurement of VLFF. PMID:27501242

  19. Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study.

    PubMed

    Sovio, Ulla; White, Ian R; Dacey, Alison; Pasupathy, Dharmintra; Smith, Gordon C S

    2015-11-21

    Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2

  20. Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis.

    PubMed

    Arbault, Anaïs; Devilliers, Hervé; Laroche, Davy; Cayot, Audrey; Vabres, Pierre; Maillefert, Jean-Francis; Ornetti, Paul

    2016-10-01

    To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure. Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intra-observer and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data. Twenty-seven patients with psoriatic arthritis (age 55.0±16.2 years, disease duration 13.4±9.4 years) were included. Of these, 67% presented nail involvement on ultrasonography vs 37% on physical examination (P<0.05). Reliability was good (ICC and weighted kappa>0.75) for the seven quantitative parameters, except for synovitis of the DIP joint in B mode. The synovitis of the DIP joint revealed by ultrasonography correlated with the total number of clinical synovitis and Doppler US of the nail (matrix and bed). Doppler US of the matrix correlated with VAS pain but not with the ASDAS-CRP or with clinical enthesitis. No significant correlation was found with US nail thickness. The feasibility and reliability of ultrasonography of the nail in psoriatic arthritis appear to be satisfactory. Among the eight parameters evaluated, power Doppler of the matrix which correlated with local inflammation (DIP joint and bed) and with VAS pain could become an interesting outcome measure, provided that it is also sensitive to change. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  1. Diagnostic utility of abdominal ultrasonography in dogs with chronic diarrhea.

    PubMed

    Leib, M S; Larson, M M; Grant, D C; Monroe, W E; Troy, G C; Panciera, D L; Rossmeisl, J H; Werre, S R

    2012-01-01

    Chronic diarrhea is common in dogs and has many causes. Ultrasonographic descriptions of many gastrointestinal diseases have been published, but the diagnostic utility of ultrasonography in dogs with chronic diarrhea has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. 87 pet dogs with chronic diarrhea. Prospective study in which medical records were reviewed and contribution of abdominal ultrasound toward making diagnosis was scored. In 57/87 (66%) of dogs, the same diagnosis would have been reached without ultrasonography. In 13/87 (15%) of dogs, the ultrasound examination was vital or beneficial to making the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with weight loss (P = .0086), palpation of an abdominal or rectal mass (P = .0031), diseases that commonly have mass lesions visible on ultrasound examination (P < .0001), and a final diagnosis of GI neoplasia. Multivariable regression indicated that utility of abdominal ultrasonography would be 30 times more likely to be high in dogs in which an abdominal or rectal mass was palpated (odds ratio 30.5, 95% CI 5.5-169.6) (P < .0001) versus dogs without a palpable mass. In 15/87 (17%) of dogs, additional benefits of ultrasonography to case management, independent of the contribution to the diagnosis of diarrhea, were identified. Overall, the diagnostic utility of abdominal ultrasonography was low in dogs with chronic diarrhea. Identification of factors associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic diarrhea. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  2. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    PubMed Central

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  3. Teaching of clinical ultrasonography to undergraduates: students as mentors.

    PubMed

    García de Casasola Sánchez, G; González Peinado, D; Sánchez Gollarte, A; Muñoz Aceituno, E; Peña Vázquez, I; Torres Macho, J

    2015-05-01

    Ultrasonography is a highly useful diagnostic technique that supplements traditional physical examinations. To demonstrate that students previously trained in clinical ultrasonography are capable of instructing other students in a similar manner in a short period of time ("peer mentoring"). Five medical students in their 5th year, trained in abdominal and cardiac ultrasonography by physicians with experience, instructed 24 other students in the same procedure. The training consisted of an online theoretical course and practical training lasting about 12hours, in which each student had to perform 6 basic abdominal planes and 4 basic cardiac planes on 20 healthy volunteers. Subsequently, the students underwent an objective assessment test on healthy models performed by expert physicians in clinical ultrasonography. The students managed to correctly identify 90.2% of the basic abdominal planes, except for the left coronal (spleen and left kidney) and subcostal (gallbladder) planes, with slightly lower success rates of 82.5% and 80%, respectively. Due to the greater difficulty of obtaining cardiac planes, the success rate was lower: 70.3%, in the subxiphoid, short parasternal and four chamber planes. The cardiac plane with the fewest errors in identification was the parasternal long plane (90% success). We observed no statistically significant differences between the results (teaching capacity) of the various mentors. Medical students are capable of instructing other colleagues (peer mentoring) on the basic aspects of abdominal and cardiac ultrasonography after a relatively short training period. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  4. Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.

    PubMed

    Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano

    2011-08-01

    Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy.

    PubMed

    Calì, Giuseppe; Timor-Trisch, Ilan E; Palacios-Jaraquemada, Josè; Monteaugudo, Ana; Forlani, Francesco; Minneci, Gabriella; Foti, Francesca; Buca, Danilo; Familiari, Alessandra; Scambia, Giovanni; Liberati, Marco; D'Antonio, Francesco

    2018-03-01

    To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) changes during pregnancy. The present retrospective analysis included women with a prenatal diagnosis of AIP that was confirmed at delivery between January 1, 2007, and April 30, 2017, at the Department of Obstetrics and Gynaecology, Arnas Civico Hospital, Palermo, Italy. Ultrasonography signs of AIP were recorded at four different intervals during pregnancy: early first (6-9 weeks), first (11-14 weeks), second (15-24 weeks), and third trimester (25-36 weeks). There were 105 pregnancies included. Low implantation of the gestational sac was present on all ultrasonography images from the early first trimester compared with on 23 of 83 (27.7%) images from 11-14 weeks of pregnancy. The identification of loss of the clear space, placental lacunae, bladder wall interruption, and uterovesical hypervascularity all increased (all P<0.001) from the early first trimester onwards; these could all be identified in a majority of patients at 11-14 weeks of pregnancy. The prevalence of ultrasonography signs suggestive of AIP varied throughout pregnancy. During the early first trimester, indicators of AIP were similar to those of a cesarean scar pregnancy; classical ultrasonography signs of AIP were already present at 11-14 weeks of pregnancy for most patients. © 2017 International Federation of Gynecology and Obstetrics.

  6. The Efficacy of Thoracic Ultrasonography in Postoperative Newborn Patients after Cardiac Surgery

    PubMed Central

    Ozturk, Erkut; Tanidir, Ibrahim Cansaran; Yildiz, Okan; Ergul, Yakup; Guzeltas, Alper

    2017-01-01

    Objective In this study, the efficacy of thoracic ultrasonography during echocardiography was evaluated in newborns. Methods Sixty newborns who had undergone pediatric cardiac surgery were successively evaluated between March 1, 2015, and September 1, 2015. Patients were evaluated for effusion, pulmonary atelectasis, and pneumothorax by ultrasonography, and results were compared with X-ray findings. Results Sixty percent (n=42) of the cases were male, the median age was 14 days (2-30 days), and the median body weight was 3.3 kg (2.8-4.5 kg). The median RACHS-1 score was 4 (2-6). Atelectasis was demonstrated in 66% (n=40) of the cases. Five of them were determined solely by X-ray, 10 of them only by ultrasonography, and 25 of them by both ultrasonography and X-ray. Pneumothorax was determined in 20% (n=12) of the cases. Excluding one case determined by both methods, all of the 11 cases were diagnosed by X-ray. Pleural effusion was diagnosed in 26% (n=16) of the cases. Four of the cases were demonstrated solely by ultrasonography, three of them solely by X-ray, and nine of the cases by both methods. Pericardial effusion was demonstrated in 10% (n=6) of the cases. Except for one of the cases determined by both methods, five of the cases were diagnosed by ultrasonography. There was a moderate correlation when all pathologies evaluated together (k=0.51). Conclusion Thoracic ultrasonography might be a beneficial non-invasive method to evaluate postoperative respiratory problems in newborns who had congenital cardiac surgery. PMID:28977200

  7. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou,

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area betweenmore » the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  8. What proportions of focal liver lesions detected by unenhanced ultrasound are inconclusive?

    PubMed Central

    Willits, Iain; Burn, Julie; Cole, Helen; Hoare, Tim

    2014-01-01

    In August 2012, the National Institute for Health and Care Excellence produced positive diagnostics guidance on the ultrasound contrast agent SonoVue®, but recommended further research involving an estimation of the proportion of unenhanced ultrasound scans reporting, but not characterising, focal liver lesions, particularly in cirrhotic livers. Patient records from the Radiology Information System of an acute hospital trust were progressively filtered based on categorical fields and keywords in the free text reports, to obtain ultrasound records including the liver that were appropriate for manual analysis. In total, 21,731 records referred from general practice or out-patient clinics were analysed. Patients described as having cirrhosis were analysed as a subgroup. After automatic exclusion of records considered likely to be negative, 5812 records were manually read and categorised as focal liver lesion inconclusive, benign or malignant. In the general practice cohort of 9175 records, 746 reported the presence of one or more focal liver lesions, with 18.4% (95% CI 15.7% to 21.3%) of these records mentioning an inconclusive focal liver lesion. In the out-patient cohort of 12,556 records, 1437 reported one or more focal liver lesions, and 29.4% (95% CI 26.9% to 32.0%) of these were inconclusive. Cirrhosis was reported in 10.8% of the out-patient scans that also reported a focal liver lesion, and 47.4% (95% CI 39.3% to 55.6%) of these scans had an inconclusive focal liver lesion, compared with 27.3% (95% CI 24.9% to 29.8%) that were inconclusive in non-cirrhotic livers (odds ratio 2.4; 95% CI 1.7 to 3.4). This retrospective study indicates that unenhanced ultrasound scans, in which a focal liver lesion is detected, are frequently inconclusive, with the probability of an inconclusive scan being greater in out-patient than general practice referrals. Inconclusive focal liver lesions were also reported in greater proportions of cirrhotic than non-cirrhotic livers. The

  9. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    PubMed

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  10. Liver schwannoma incidentally discovered in a patient with breast cancer.

    PubMed

    Akin, Murat; Bozkirli, Bahadir; Leventoglu, Sezai; Unal, Kemal; Kapucu, L Ozlem; Akyurek, Nalan; Sare, Mustafa

    2009-01-01

    Benign schwannomas, also referred to as neurilemomas, neurinomas, and perineural fibroblastomas, are encapsulated nerve sheath tumors. Primary schwannomas of the liver are extremely rare. We present a case of liver schwannoma, incidentally found in a patient with breast cancer. A 66-year-old female consulted her physician for a mass she palpated on her left breast. The abdominal ultrasonography (USG) revealed a 44 x 28 mm mass in the medial segment of the left lobe of her liver suspicious of a metastasis. An USG-guided biopsy was performed and the histo-pathological examination revealed a "peripheral nerve sheath tumor". Positron emission tomography (PET-CT) revealed a pathologic FDG uptake in the lesion that was previously defined in the liver. The tumor resected from the liver was 5 x 4 x 3 cm, yellowish, soft, and capsulated tumor. Microscopic examination revealed that the mass consisted of bundles of spindle cells with hypercellular and hypocellular areas. In immunohistochemistry, there was a strong positive staining for S-100. The tumor was diagnosed as benign liver schwannoma. Schwannomas are benign, encapsulated neoplasms. Symptoms and signs vary depending on the anatomical site and the size of the neoplasm; however, most schwannomas present as an asymptomatic or painless mass. Recurrence is unusual, despite of an incomplete removal, and malignant transformation is exceedingly rare (Fig. 4, Ref. 8). Full Text (Free, PDF) www.bmj.sk.

  11. Evaluation of the Causes of Erectile Dysfunction in Patients Undergoing Penile Doppler Ultrasonography in Pakistan

    PubMed Central

    Khanzada, Usman; Khan, Sohail Ahmed; Hussain, Munawar; Adel, Hatem; Masood, Kamran; Manohar, Murli

    2017-01-01

    Purpose In patients with erectile dysfunction, it is important to differentiate psychogenic from organic causes. Penile Doppler ultrasonography is a relatively inexpensive and minimally invasive tool for this purpose. This study was conducted to evaluate the causes of erectile dysfunction in an adult male population, using penile Doppler ultrasonography. Materials and Methods A retrospective study was conducted in a single center. All patients who presented with complaints of erectile dysfunction and underwent penile Doppler ultrasonography between July 2014 and June 2016 were included in this study. All examinations were performed using GE Voluson S6 and GE Logiq P5 devices. Following baseline scans, an intracavernosal injection of 20 µg of prostaglandin E1 was given. Peak systolic and end diastolic velocities were measured in each cavernosal artery. Patients with a peak systolic velocity of <25 cm/s were considered to have arterial insufficiency, while an end diastolic velocity of >5 cm/s was considered to indicate venous incompetence. Results Out of 97 patients (mean age, 37.09±11.59 years; range, 19~69 years), 50 patients (51.5%) had normal findings, 24 patients (24.7%) had arterial insufficiency, 15 patients (15.5%) had a venous leak, and 8 patients (8.2%) patients had arterial insufficiency with a venous leak. Psychogenic erectile dysfunction was significantly higher among patients aged ≤40 years, while arterial insufficiency with or without a venous leak was significantly higher among patients aged >40 years (p=0.022). Conclusions A majority of the studied individuals demonstrated no organic cause of erectile dysfunction, thus confirming a high prevalence of the psychogenic etiology, particularly in relatively young individuals. PMID:28459144

  12. SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takao, S; Matsuzaki, Y; Matsuura, T

    Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of amore » combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D{sub 5}/D{sub 95}) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.« less

  13. Diagnostic utility of abdominal ultrasonography in dogs with chronic vomiting.

    PubMed

    Leib, M S; Larson, M M; Panciera, D L; Troy, G C; Monroe, W E; Rossmeisl, J H; Forrester, S D; Herring, E S

    2010-01-01

    Chronic vomiting is a common problem in dogs that has many causes. Ultrasonographic descriptions of many gastrointestinal (GI) diseases have been published. However, diagnostic utility of ultrasonography in dogs with chronic vomiting has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. Eighty-nine pet dogs with chronic vomiting. Medical records were reviewed and the contribution of abdominal ultrasound to the clinical diagnosis was subjectively scored. In 68.5% of dogs, the reviewers thought that the same diagnosis would have been reached without performing ultrasonography. In 22.5% of dogs, the ultrasound examination was considered to be vital or beneficial to the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with increasing age, a greater number of vomiting episodes per week, presence of weight loss, a greater percentage of lost body weight, and a final diagnosis of GI lymphoma or gastric adenocarcinoma. However, multivariate analysis only identified increasing age and a final diagnosis of gastric adenocarcinoma or GI lymphoma to be associated with increased diagnostic utility. In 12.4% of dogs, additional benefits of ultrasonography to case management, excluding the contribution to the vomiting problem, were identified. The diagnostic utility of abdominal ultrasonography was high in 27% of dogs. The presence of factors that are associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic vomiting.

  14. Comparison of renal ultrasonography and dimercaptosuccinic acid renal scintigraphy in febrile urinary tract infection.

    PubMed

    Ayazi, Parviz; Mahyar, Abolfazl; Noroozian, Elham; Esmailzadehha, Neda; Barikani, Ameneh

    2015-12-01

    Accurate and early diagnosis and appropriate treatment of patient with urinary tract infection (UTI) are essential for the prevention or restriction of permanent damage to the kidneys in children. The aim of this study was to compare renal ultrasonography (US) and dimercaptosuccinic acid (DMSA) renal scan in the diagnosis of patients with febrile urinary tract infection. This study involved the medical records of children with febrile urinary tract infection who were admitted to the children's hospital in Qazvin, Iran. Pyelonephritis was diagnosed on the basis of clinical symptoms, laboratory tests and abnormal DMSA renal scans. The criteria for abnormality of renal US were an increase or a decrease in diffuse or focal parenchymal echogenicity, loss of corticomedullary differentiation, kidney position irregularities, parenchymal reduction and increased kidney size. Of the 100 study patients, 23% had an abnormal US and 46% had an abnormal DMSA renal scan. Of the latter patients, 15 had concurrent abnormal US (P value ≤ 0.03, concordance rate: 18%). Renal US had a sensitivity of 32%, specificity of 85%, positive predictive value of 65% and negative predictive value of 60%. Of the 77 patients with normal US, 31 (40.2%) had an abnormal DMSA renal scan. Despite the benefits and accessibility of renal US, its value in the diagnosis of pyelonephritis is limited.

  15. Intraoperative Ultrasonography during Drainage for Chronic Subdural Hematomas: A Technique to Release Isolated Deep-seated Hematomas—Technical Note

    PubMed Central

    SHIMIZU, Satoru; MOCHIZUKI, Takahiro; OSAWA, Shigeyuki; KUMABE, Toshihiro

    2015-01-01

    After the drainage of chronic subdural hematomas (CSDHs), residual isolated deep-seated hematomas (IDHs) may recur. We introduce intraoperative ultrasonography to detect and remove such IDHs. Intra-operative ultrasonography is performed with fine transducers introduced via burr holes. Images obtained before dural opening show the CSDHs, hyper- and/or hypoechoic content, and mono- or multilayers. Images are also acquired after irrigation of the hematoma under the dura. Floating hyperechoic spots (cavitations) on the brain cortex created by irrigation confirm the release of all hematoma layers; areas without spots represent IDHs. Their overlying thin membranes are fenestrated with a dural hook for irrigation. Ultrasonographs were evaluated in 43 CSDHs (37 patients); 9 (21%) required IDH fenestration. On computed tomography scans, 17 were homogeneous-, 6 were laminar-, 16 were separated-, and 4 were trabecular type lesions. Of these, 2 (11.8%), 3 (50%), 4 (25%), and 0, respectively, manifested IDHs requiring fenestration. There were no technique-related complications. Patients subjected to IDH fenestration had lower recurrence rates (11.1% vs. 50%, p = 0.095) and required significantly less time for brain re-expansion (mean 3.78 ± 1.62 vs. 18 ± 5.54 weeks, p = 0.0009) than did 6 patients whose IDHs remained after 48 conventional irrigation and drainage procedures. Intraoperative ultrasonography in patients with CSDHs facilitates the safe release of hidden IDHs. It can be expected to reduce the risk of postoperative hematoma recurrence and to shorten the brain re-expansion time. PMID:26345671

  16. SSAT/AHPBA Joint Symposium on Evaluation and Treatment of Benign Liver Lesions

    PubMed Central

    Chun, Yun Shin; House, Michael G.; Kaur, Harmeet; Loyer, Evelyne M.; Paradis, Valérie; Vauthey, Jean-Nicolas

    2013-01-01

    Background Benign liver lesions are common incidental radiologic findings. Methods Experts convened in 2011 at a Society for Surgery of the Alimentary Tract/ Americas Hepato-Pancreato-Biliary Association joint symposium to discuss the evaluation and treatment of benign liver lesions. Results Most benign liver lesions can be accurately diagnosed with high-quality imaging, including ultrasonography, multiphase computed tomography, and magnetic resonance imaging, particularly with hepatocyte-specific contrast agents. Percutaneous biopsy is reserved for lesions that cannot be characterized radiographically, and its accuracy is improved with immunophenotypic markers. Hepatic cysts are the most commonly diagnosed benign liver lesions; these must be distinguished from malignant cystic lesions, which are rare. Among the solid benign liver lesions, hemangiomas and focal nodular hyperplasia seldom require treatment. In contrast, hepatocellular adenomas are associated with a risk for complications. A new classification system for hepatocellular adenomas based on genetic and phenotypic features can help guide patient care. In patients who are symptomatic or at risk for complications, multidisciplinary evaluation and treatment based on clinicopathologic, radiographic, and molecular analysis is needed. Conclusions Most benign liver lesions can be accurately diagnosed radiographically and do not require treatment. Treatment is necessary for patients with symptoms or at risk for complications. PMID:23377783

  17. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    PubMed

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7

  18. Biphasic effect of alcohol intake on the development of fatty liver disease.

    PubMed

    Takahashi, Hirokazu; Ono, Masafumi; Hyogo, Hideyuki; Tsuji, Chika; Kitajima, Yoichiro; Ono, Naofumi; Eguchi, Takahisa; Fujimoto, Kazuma; Chayama, Kazuaki; Saibara, Toshiji; Anzai, Keizo; Eguchi, Yuichiro

    2015-11-01

    Fatty liver is an important clinical feature not only in alcoholic and non-alcoholic fatty liver diseases, but in other chronic liver diseases as well. Our aim was to elucidate the effect and relationship between habitual alcohol intake and obesity in the development of fatty liver disease. We enrolled 8,029 subjects undergoing abdominal ultrasonography with general medical examinations, and analyzed the factors associated with fatty liver based on daily alcohol intake, body mass index (BMI), and waist circumference. For fatty liver, BMI, waist circumference, total cholesterol, triglycerides, and fasting plasma glucose were significant and independent risk factors. Heavy alcohol intake (50 g/day) was a significant risk factor for fatty liver in women (odds ratio [OR], 3.35). Analysis based on the presence or absence of obesity revealed that moderate alcohol intake was a significant negative risk factor for fatty liver in both male and female obese (BMI ≥25 kg/m(2)) subjects (OR, 0.74 for non-obese and 0.39 for obese patients, respectively). Heavy alcohol intake was also a significant negative risk factor in obese males (0.62). In contrast, heavy alcohol intake was a risk factor in non-obese males (OR, 1.29) and in all females (OR, 2.22 for non-obese and 6.6 for obese patients, respectively). The influence of alcohol intake on fatty liver differed depending on the level of alcohol consumption, gender, and the presence of obesity, and showed biphasic effects.

  19. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    PubMed Central

    Znajdek, Michał; Gietka, Piotr; Vasilevska-Nikodinovska, Violeta; Patrovic, Lukas; Salapura, Vladka

    2017-01-01

    Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging. PMID:29075522

  20. The persistence of fatty liver has a differential impact on the development of diabetes: The Kangbuk Samsung Health Study.

    PubMed

    Bae, Ji Cheol; Han, Ji Min; Cho, Jung Hwan; Kwon, Hyemi; Park, Se Eun; Park, Cheol-Young; Lee, Won-Young; Oh, Ki-Won; Kwon, Sam; Park, Sung-Woo; Rhee, Eun Jung

    2018-01-01

    To evaluate whether variable fatty liver status over time influence the risk of type 2 diabetes differently. We analyzed the data from 7849 subjects without type 2 diabetes who underwent comprehensive health check-ups annually for 5 years. All subjects had an abdominal ultrasonography annually. The risk of incident diabetes was assessed in individuals with sustained non-alcoholic fatty liver disease (NAFLD), individuals with changed fatty liver status (intermittent NAFLD group), and individuals who did not have NAFLD (never NAFLD group) during the study period. A subgroup analysis was done in subjects of the intermittent NAFLD group. Incident diabetes was compared according to the number of time diagnosed as NAFLD by annual ultrasonography. During the mean follow-up of 4 years, subjects in the sustained NAFLD group had a HR of 1.50 (95% CI 1.13-1.98) for the development of diabetes compared with those in the never NAFLD group, whereas the risk was not higher in the intermittent NAFLD group (HR 0.99, 95% CI 0.76-1.31). When compared with the intermittent NAFLD group, multivariable adjusted HR for incident diabetes was 1.50 (95% CI 1.20-1.89) in the sustained NAFLD group. As the number of times diagnosed as NAFLD increased, the proportion of subjects who developed diabetes also increased (p = .002). The presence of fatty liver was differentially associated with incident diabetes based on its duration. The persistence of fatty liver status is an important factor for an independent association between NAFLD and incident diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Study on text mining algorithm for ultrasound examination of chronic liver diseases based on spectral clustering

    NASA Astrophysics Data System (ADS)

    Chang, Bingguo; Chen, Xiaofei

    2018-05-01

    Ultrasonography is an important examination for the diagnosis of chronic liver disease. The doctor gives the liver indicators and suggests the patient's condition according to the description of ultrasound report. With the rapid increase in the amount of data of ultrasound report, the workload of professional physician to manually distinguish ultrasound results significantly increases. In this paper, we use the spectral clustering method to cluster analysis of the description of the ultrasound report, and automatically generate the ultrasonic diagnostic diagnosis by machine learning. 110 groups ultrasound examination report of chronic liver disease were selected as test samples in this experiment, and the results were validated by spectral clustering and compared with k-means clustering algorithm. The results show that the accuracy of spectral clustering is 92.73%, which is higher than that of k-means clustering algorithm, which provides a powerful ultrasound-assisted diagnosis for patients with chronic liver disease.

  2. Laparoscopic thermoablation of colorectal cancer metastases to the liver - new experience of the centre.

    PubMed

    Murawa, Dawid; Spychała, Arkadiusz; Lewandowski, Adam; Nowaczyk, Piotr

    2012-01-01

    Thermoablation of metastatic lesions in the liver is very commonplace. At present there are 3 essential techniques of access to carry out the procedure: open surgery, percutaneous technique and laparoscopic method. Percutaneous thermoablation is criticised due to the possible lack of radicalism. On the other hand, thermoablation during open surgery is a big perioperative trauma for the patient. The laparoscopic technique seems to be a compromise between the aforementioned techniques. The aim of this study was to present the technique and preliminary results of thermoablation of the liver carried out by means of the laparoscopic technique. Laparoscopic thermoablation was carried out in 4 patients with colorectal cancer metastases to the liver. In order to precisely locate the tumour and guarantee radicalism of the surgery, laparoscopic probe ultrasonography was carried out during the procedure. All the patients underwent the procedure without any difficulties. All the patients left the hospital department as soon as 3 or 4 days after the surgery. This was about 7 days earlier in comparison with the open surgery procedure, which had been carried out before. The patients required a supply of analgesics only during the first 48 hours - non-steroid anti-inflammatory drugs, which made a substantial difference between them and the patients treated with the open surgical technique. Thanks to the laparoscopic ultrasound technique one patient had an additional lesion located, which had not been described in preoperative examinations. In combination with ultrasonography, laparoscopic access, which does not have a very invasive character, seems to be relatively simple and effective to carry out the procedure of thermoablation.

  3. Association between liver fibrosis and coronary heart disease risk in patients with nonalcoholic fatty liver disease.

    PubMed

    Dogan, Serkan; Celikbilek, Mehmet; Yilmaz, Yunus K; Sarikaya, Savas; Zararsiz, Gokmen; Serin, Halil I; Borekci, Elif; Akyol, Lütfi; Pirti, Ilyas; Davarci, Sena E

    2015-03-01

    Nonalcoholic fatty liver disease (NAFLD) is being increasingly recognized as the most common cause of chronic liver disease worldwide. It has been shown that NAFLD in adults is associated with increased risk of coronary heart disease (CHD). Because of the limitations of liver biopsy, noninvasive scoring indexes such as the NAFLD fibrosis score (NFS) were developed. The Framingham risk score (FRS) provides an estimate of CHD risk. In our study we aimed to investigate whether the severity of liver fibrosis estimated with the NFS is associated with a higher risk of CHD among individuals with ultrasonography-diagnosed NAFLD. A total of 155 patients and controls (81 patients with NAFLD and 74 controls) with ages ranging from 18 to 70 years were enrolled in this cross-sectional prospective study. Demographic, anthropometric, clinical, and laboratory data were obtained from each individual. The NAFLD patients were divided into subgroups on the basis of the severity of fatty liver. The FRS and NFS were adopted to predict the risk of CHD and the severity of hepatic fibrosis. In our study, we found that the FRS was higher in NAFLD patients than in controls (P<0.05). According to the FRS category, NFSs were higher in the intermediate/high probability CHD risk group in NAFLD (P<0.05). In multiple models, only age, sex, cholesterol, and HDL were independently associated with intermediate/high CHD risk (P<0.05). We also found a positive correlation between the NFS and the FRS (r=0.373, P<0.001). The optimum NFS cutoff point for identifying intermediate/high CHD risk in NAFLD patients was -2.1284, with a sensitivity and specificity of 95.20 and 48.30%, respectively. The predictive performance of the NFS in the determination of intermediate/high CHD risk in NAFLD patients was found to be 72% based on the area under the curve value. The FRS is associated with the NFS in NAFLD. The assessment of liver fibrosis may be useful for the risk stratification of CHD in the absence of liver

  4. Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com

    2015-02-15

    PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize themore » tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.« less

  5. Hepatic perivascular epithelioid cell tumor (PEComa): dynamic CT, MRI, ultrasonography, and pathologic features--analysis of 7 cases and review of the literature.

    PubMed

    Tan, Yan; Xiao, En-hua

    2012-10-01

    To evaluate the dynamic CT, MRI, ultrasonography, and pathologic features of hepatic perivascular epithelioid cell tumor (PEComa), improving the understanding and diagnosis of the tumor. A retrospective analysis of CT, MRI, ultrasonography, and pathologic features of 7 hepatic PEComas diagnosed by pathology during 1st January 2005 to 1st September 2011 in our hospital. The performance of dynamic CT, MRI, and ultrasonography revealed that lesions were regular masses with well-defined borders, the maximum diameters were 2.5-8.5 cm (mean = 4 cm), density was homogeneous, contrast-enhanced CT and MRI showed the lesions were significantly and heterogeneously enhanced on arterial phase, less enhanced on portal venous phase, and slightly hypodense on delayed phase. One patient had multiple hepatic lesions and had delayed enhancement. There were no backgrounds of hepatitis and cirrhosis, enlarged lymph nodes, or distant metastases. Pathology showed the gross appearance of the tumor was smooth. Tumor cells were round or polygonal, with clear boundaries and clear membranes, and had abundant translucent cytoplasm. Nuclei were round, with medium size. Tumor cells were epithelial-like cells and arranged in dense sheets. Immunohistochemistry showed that most of them were positive in HMB45 and MelanA, S-100, SMA, while negative in CgA, Syn, CK, CD117, CD10, and CD34. Dynamic CT, MRI, ultrasonography, and pathology of PEComa had some characteristics of benign tumor's performance. Enhanced scan showed PEComa quickly enhanced on arterial phase and enhanced less on portal venous phase. Knowing these characteristics could help to improve the understanding and diagnosis of hepatic PEComa.

  6. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    PubMed

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  7. Shear-wave elastography in breast ultrasonography: the state of the art

    PubMed Central

    2017-01-01

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy. PMID:28513127

  8. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    PubMed

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups <40, 40-49, 50-59 and >59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  9. Causes of altered liver function tests - the role of alpha-1 antitrypsin.

    PubMed

    Stollenwerk, J; Schepke, M; Biecker, E

    2016-09-01

    Altered liver function tests are a common finding in clinical practice. Our retrospective study aimed to identify the diagnoses in a non-selected cohort of patients with altered liver tests and to investigate whether alpha-1 antitrypsin genotyping should be part of the diagnostic workup. 501 patients who were admitted to our outpatient clinic for further evaluation of altered liver function tests were included in the study. The patients underwent a standardized diagnostic program with history taking, physical examination, laboratory tests and ultrasonography. Liver biopsy was performed if appropriate. More than 50 % of the patients had nonalcoholic fatty liver disease. Alcoholic and drug-induced liver injury were found in 8.6 % and 7 % of patients, respectively. Chronic hepatitis B and C, autoimmune liver disease and inherited causes of liver disease made up for approximately 16 % of the diagnoses. The remaining patients were diagnosed with kryptogenic liver disease or had miscellaneous diagnoses. In 3.7 % of the genotyped patients, the alpha-1 antitrypsin genotype PiMZ was found. Nonalcoholic fatty liver disease is nowadays the most frequent cause of altered liver tests. Alcoholic liver disease might be underrepresented in our study since these patients less often seek medical attention or the diagnosis is already made by the primary care physician. Drug-induced liver injury was found in more patients than expected and might therefore be underdiagnosed in practice. The alpha-1 antitrypsin genotype PiMZ was found in absence of other possible causes of liver disease, indicating that the PiMZ genotype is itself a risk factor for liver disease. Genotyping for alpha-1 antitrypsin should therefore be done when other causes for altered liver function tests have been ruled out. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Increased H-FABP concentrations in nonalcoholic fatty liver disease. Possible marker for subclinical myocardial damage and subclinical atherosclerosis.

    PubMed

    Başar, O; Akbal, E; Köklü, S; Tuna, Y; Koçak, E; Başar, N; Tok, D; Erbiş, H; Senes, M

    2013-06-01

    Nonalcoholic fatty liver disease (NAFLD) is the most common liver disorder which is reported as the hepatic manifestation of metabolic syndrome with an increased risk of cardiovascular events. Patients with NAFLD are also at risk of future cardiac events independently of metabolic syndrome. The aim of this study was to examine serum concentrations of heart type fatty acid binding protein (H-FABP) in NAFLD and to investigate its correlations with metabolic parameters and subclinical atherosclerosis. A total of 34 patients with NAFLD and 35 healthy subjects were enrolled in the study. NAFLD patients had elevated liver enzymes and steatosis graded on ultrasonography. Healthy subjects had normal liver enzymes and no steatosis on ultrasonography. H-FABP levels were measured using an enzyme linked immunosorbent assay (ELISA) method and correlations with metabolic parameters and subclinical atherosclerosis were examined. Subclinical atherosclerosis was determined with carotid artery intima-media thickness (CIMT) which was measured by high resolution B mode ultrasonography. H-FABP levels were elevated in patients with NAFLD (16.3 ± 4.0 ng/ml) when compared with healthy controls (13.8 ± 2.1 ng/ml; p  < 0.001). NAFLD patients had significantly higher CIMT than the controls had (0.64 ± 0.17 mm vs. 0.43 ± 0.14 mm, p = 0.009). The H-FABP concentrations were significantly positively correlated with body mass index (r = 0.255, p = 0.042), fasting blood glucose level (r = 0.300, p = 0.013), CIMT (r = 0.335, p = 0.043), and homeostasis model assessment-estimated insulin resistance (HOMA-IR; r = 0.156, p = 0.306). In multiple linear regression analysis, H-FABP levels were only independently associated with CIMT (p = 0.04) Serum H-FABP concentrations increase in patients with NAFLD. Our results may not only suggest that H-FABP is a marker of subclinical myocardial damage in patients with NAFLD but also of

  11. Usability of virtual-reality simulation training in obstetric ultrasonography: a prospective cohort study.

    PubMed

    Burden, C; Preshaw, J; White, P; Draycott, T J; Grant, S; Fox, R

    2013-08-01

    To assess the usability of virtual-reality (VR) simulation for obstetric ultrasound trainees. Twenty-six participants were recruited: 18 obstetric ultrasound trainees (with little formal ultrasonography training) and eight certified experts. All performed five sequential VR-simulated crown-rump length (CRL) scans in a single session and three repetitions of biparietal diameter (BPD), occipitofrontal diameter (OFD) and femur length (FL) measurements. Outcome measures included mean percentage deviation from target for all measurements. Time taken to perform each type of scan was recorded. The mean percentage difference for the first scan was significantly greater for the trainee group than for the expert group for BPD (P = 0.035), OFD (P = 0.010) and FL (P = 0.008) and for time taken for the first CRL (P < 0.001) and fetal biometry (including BPD, OFD and FL measurements) scan (P < 0.001), demonstrating that trainees were initially significantly less accurate and less efficient. Over subsequent scans, the trainees became more accurate for all measurements with a significant improvement shown for OFD and FL (P < 0.05). The time taken for trainees to complete CRL and fetal biometry scans decreased significantly (all P < 0.05) with repetition, to near-expert efficiency. All participants were able to use the simulator and produce clinically meaningful biometry results. With repetition, beginners quickly approached near-expert levels of accuracy and speed. These data demonstrate that obstetricians with minimal experience can improve their ultrasonographic skills with short-phase VR-simulation training. The speed of improvement suggests that VR simulation might be useful as a warm-up exercise before clinical training sessions in order to reduce their impact on clinical service. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  12. Doppler ultrasonographic and scintigraphic assessment of an auxiliary heterotopic liver transplantation with portal vein arterialization in pigs.

    PubMed

    Fernández-Rodríguez, O M; Ríos, A; Navarro, J L; Pons, J A; Palenciano, C G; Mota, R; Berenguer, J J; Mulero, F; Contreras, J; Conesa, C; Ramírez, P; Fuente, T; Parrilla, P

    2006-04-01

    Our aim was to evaluate liver graft integrity and function using scintigraphy and ultrasonography in a porcine model of auxiliary heterotopic liver transplantation with portal vein arterialization (AHLT-PVA). Using Doppler ultrasonography we evaluated eight AHLT-PVA by parenchymal echogenicity, portal and arterial anatomy, and portal and biliary system flow. Two types of scintigraphy were performed: microaggregated human albumin colloid scintigraphy and diisopropyl iminodiacetic acid (DISIDA) scintigraphy, both labeled with 99mTc. The animals were distributed into two groups. The first group consisted of three animals with clinical suspicion of graft dysfunction, in which the ultrasonographic study revealed areas of parenchymal destructuring. In the scintigraphic study, heterogenous uptake was observed; there was no uptake in one animal. Necropsy of these three animals revealed areas of graft necrosis. The second group consisted of five animals with good clinical evolutions, in which the ultrasonographic study showed portal dilation, portal flow with arterial spiculations, and homogenous echogenicity of the hepatic parenchyma. The scintigraphic study revealed homogenous uptake by the graft and an elimination speed of the hepatobiliary agent similar to that of the native liver. An heterogenous echostructure of the graft provided a sign of poor prognosis indicating necrosis in the same way as heterogenous uptake or nonuptake of radioisotope upon scintigraphy. Scintigraphy is a good method to evaluate biliary function and bile elimination. In an AHLT-PVA, the main ultrasound findings derived from arterialization were dilation of the portal system and portal flow with arterial spiculations.

  13. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    PubMed Central

    Athar, Hakim; Mohindroo, Jitender; Singh, Kiranjeet; Kumar, Ashwani; Raghunath, Mulinti

    2010-01-01

    The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow) were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67%) with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18%) and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines. PMID:20445795

  14. Performance of physical examination versus ultrasonography to detect stenosis in haemodialysis arteriovenous fistula.

    PubMed

    Maldonado-Cárceles, Ana B; García-Medina, José; Torres-Cantero, Alberto M

    2017-01-18

    The overall purpose of this study is to compare the accuracy of physical examination (PE) versus ultrasonography (US) in people with arteriovenous fistula (AVF). This is a cross-sectional study with a total of 99 patients attended by the vascular radiology unit for AVF evaluation during January - March 2015. PE and ultrasonography were blinded performed by different radiologists. For complete and individual signs of PE, sensitivity, specificity, predictive positive (PPV) and negative (PNV) value, likelihood ratios (LR) and Cohen's κ value were measured. According to ultrasonography, the presence of stenosis was identified in 57 (58%) patients, and 61 (62%) by PE. The accuracy of PE for the diagnosis of AVF was sensitivity 82%, specificity 67%, PPV 77%, NPV 74%, LR 2.74 and 0.26. There was a moderate agreement beyond chance between PE and ultrasonography (κ = 0.5). PE has shown a moderate accuracy to detect stenosis. With non-ultrasonography availability Haemodialysis Units can get benefit to optimize VA survival and professionals should improve its basic skills.

  15. Percutaneous Angioplasty of Portal Vein Stenosis that Complicates Liver Transplantation: The Mid-Term Therapeutic Results

    PubMed Central

    Park, Kwang Bo; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In-Wook

    2005-01-01

    Objective We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. Materials and Methods From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. Results The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Conclusion Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique. PMID:16145291

  16. Variations of ultrasonic anatomy of the hepatic veins within the human liver.

    PubMed

    Lamanna, I; Bilić, A; Ljubicić, N; Bakula, B

    1990-01-01

    The aim of this study was to investigate various physiological variations of the hepatic veins within the liver of the 60 healthy subjects. All participants required physical examinations, different laboratory tests and upper abdominal ultrasonogram--all completely normal. Demonstration of the hepatic veins have been performed on sector real-time systems. The results clearly demonstrated that the physiological variations of the hepatic veins are very common. Ultrasonography obviously represents a diagnostic method of choice in the evaluation of anatomy of the hepatic venous system.

  17. Metastatic Neuroblastoma in Adult Patient, Presenting as a Super Scan on 68Ga-DOTANOC PET/CT Imaging.

    PubMed

    Malik, Dharmender; Jois, Abhiram; Singh, Harmandeep; Bora, Girdhar S; Basher, Rajender Kumar; Mittal, Bhagwant Rai

    2017-09-01

    We report a case of 23-year-old man who presented with complaints of progressive abdominal distension for the past 3 months along with the loss of appetite and weight and had a large solid cystic mass in the left half of the abdominal cavity revealed on ultrasonography and contrast-enhanced CT of the abdomen. Subsequent biopsy and histopathology revealed it to be neuroblastoma. Ga-DOTANOC PET/CT scan performed to rule out distant metastasis showed intense radiotracer uptake distributed throughout the skeleton, mimicking a super scan.

  18. Reproducibility of CT Perfusion Parameters in Liver Tumors and Normal Liver

    PubMed Central

    Ng, Chaan S.; Chandler, Adam G.; Wei, Wei; Herron, Delise H.; Anderson, Ella F.; Kurzrock, Razelle; Charnsangavej, Chusilp

    2011-01-01

    Purpose: To assess the reproducibility of computed tomographic (CT) perfusion measurements in liver tumors and normal liver and effects of motion and data acquisition time on parameters. Materials and Methods: Institutional review board approval and written informed consent were obtained for this prospective study. The study complied with HIPAA regulations. Two CT perfusion scans were obtained 2–7 days apart in seven patients with liver tumors with two scanning phases (phase 1: 30-second breath-hold cine; phase 2: six intermittent free-breathing cines) spanning 135 seconds. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability–surface area product (PS) for tumors and normal liver were calculated from phase 1 with and without rigid registration and, for combined phases 1 and 2, with manually and rigid-registered phase 2 images, by using deconvolution modeling. Variability was assessed with within-patient coefficients of variation (CVs) and Bland-Altman analyses. Results: For tumors, BF, BV, MTT, and PS values and reproducibility varied by analytical method, the former by up to 11%, 23%, 21%, and 138%, respectively. Median PS values doubled with the addition of phase 2 data to phase 1 data. The best overall reproducibility was obtained with rigidly registered phase 1 and phase 2 images, with within-patient CVs for BF, BV, MTT, and PS of 11.2%, 14.4%, 5.5% and 12.1%, respectively. Normal liver evaluations were similar, except with marginally lower variability. Conclusion: Absolute values and reproducibility of CT perfusion parameters were markedly influenced by motion and data acquisition time. PS, in particular, probably requires data acquisition beyond a single breath hold, for which motion-correction techniques are likely necessary. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110331/-/DC1 PMID:21788525

  19. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    PubMed

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  20. Brain Ultrasonography Findings in Neonatal Seizure; a Cross-sectional Study.

    PubMed

    Nabavi, Seyed Saeed; Partovi, Parinaz

    2017-01-01

    Screening of newborns with seizure, who have curable pathologic brain findings, might be able to improve their final outcome by accelerating treatment intervention. The present study aimed to evaluate the brain ultrasonography findings of newborns hospitalized with complaint of seizure. The present cross-sectional study designed to evaluate brain ultrasonography findings of hospitalized newborns complaining seizure. Neonatal seizure was defined as presence of tonic, clonic, myoclonic, and subtle attacks in 1 - 28 day old newborns. 100 newborns with the mean age of 5.82 ± 6.29 days were evaluated (58% male). Most newborns were in the < 10 days age range (76%), term (83%) and with normal birth weight (81%). 22 (22%) of the ultrasonography examinations showed a pathologic finding. A correlation was only found between birth age and probability of the presence of a pathologic problem in the brain as the frequency of these problems was significantly higher in pre-term newborns (p = 0.023). Based on the findings of the present study, frequency of pathologic findings in neonatal brain ultrasonography was 22%. Hemorrhage (12%) and hydrocephaly (7%) were the most common findings. The only factor correlating with increased probability of positive findings was the newborns being pre-term.

  1. Semi-closed reduction of tripod fractures of zygoma under intraoperative assessment using ultrasonography.

    PubMed

    Soejima, Kazutaka; Sakurai, Hiroyuki; Nozaki, Motohiro; Kitazawa, Yoshihiko; Takeuchi, Masaki; Yamaki, Takashi; Kono, Taro

    2009-04-01

    We conducted semi-closed reduction of isolated tripod fractures of the zygoma through only a brow incision under intraoperative assessment with ultrasonography. Twenty-three patients with unilateral, non-comminuted tripod fractures of zygoma were selected for application of this method at Tokyo Women's Medical University and Tokyo Metropolitan Hiroo General Hospital between April 2002 and April 2006. Patients with orbital floor blowout fractures were excluded. A skin incision was made only at the lateral brow region and the reduction was performed by inserting an elevator beneath the zygomatic arch. The bone alignment was intraoperatively assessed by ultrasonography. When the reduction was accurate, the frontozygomatic suture was immobilised with a mini-plate under direct visualisation and transmaler Kirshner wire fixation was performed. The accuracy of the reduction and postoperative movement were evaluated by computed tomography (CT) scans taken at 1 and 6 months. In five cases, the DICOM (Digital Imaging and Communication in Medicine) data from the CT were analysed with 3D imaging software (V-works, CyberMed Co., Korea). In all cases, accurate reduction was obtained. The analysis of the 3D imaging data revealed that postoperative movement of bone fragment was minimal. When the accurate reduction was obtained under intraoperative assessment, the semi-closed reduction and one-plate fixation with transmaler Kirshner wire is enough to treat the simple tripod fractures of zygoma. This method is minimally invasive and takes less operative time.

  2. A Klebsiella pneumoniae liver abscess presenting with myasthenia and tea-colored urine

    PubMed Central

    Deng, Lihua; Jia, Rong; Li, Wei; Xue, Qian; Liu, Jie; Miao, Yide; Wang, Jingtong

    2017-01-01

    Abstract Rationale: Rhabdomyolysis is a well-known syndrome in clinical practice, although rhabdomyolysis caused by a liver abscess is rarely reported and the patient may lack symptoms that are associated with a primary site of infection. Early recognition of this possibility is needed to avoid diagnostic delay and facilitate treatment. We report the case of a 71-year-old woman with a Klebsiella pneumoniae (KP) pyogenic liver abscess who presented with myasthenia and tea-colored urine and also review the 77 reported cases of bacterial rhabdomyolysis. Patient concerns: The patient was 71 years old and presenting with a 7-day history of myasthenia and a 3-day history of tea-colored urine, but without fever or abdominal pain. Diagnoses: Laboratory testing in our case revealed rhabdomyolysis, and blood culture revealed KP. Abdominal ultrasonography revealed a hypoechoic enclosed mass, and computed tomography (CT) revealed an enclosed low-density mass (8.3 × 6.6 × 6.1 cm). The main diagnoses were a pyogenic liver abscess with rhabdomyolysis. Interventions: Empirically intravenous piperacillin-sulbactam and intravenous potassium treatment, as well as fluid infusions and other supportive treatments were provided after admission. After the diagnosis was confirmed and susceptibility test results were available, we adjusted the antibiotics to cefoperazone and sulbactam, which were maintained for 6 weeks. Outcomes: The patient's symptoms relieved and the abnormal laboratory parameters corrected. Follow-up abdominal ultrasonography at 24 months after her discharge revealed that the abscess had disappeared. Lessons: Early recognition and careful consideration of the underlying cause of rhabdomyolysis are critical to improving the patient's prognosis. Thus, physicians should carefully consider the underlying cause in elderly patients who present with rhabdomyolysis, as they may lack symptoms of a primary infection. PMID:29390582

  3. Serum endocan levels in patients with chronic liver disease

    PubMed Central

    Tok, Duran; Ekiz, Fuat; Basar, Omer; Coban, Sahin; Ozturk, Gulfer

    2014-01-01

    Background and Aim: Early detection of fibrosis should be the main goal of treatment in liver cirrhosis. Endocan, previously called endothelial cell specific molecule-1, is expressed by endothelial cells, primarily in the lung, liver and kidney. In this study, we aimed to examine the correlation of liver fibrosis stage, histological activity and grade of steatosis between serum levels of endocan in patients with chronic hepatitis B (CHB), chronic hepatitis C (CHC) and non-alcoholic fatty liver disease (NAFLD). Patients and Methods: This cross-sectional study includes a total of 146 subjects. 55 CHB patients, 19 CHC patients, 38 NAFLD patients and 34 healthy controls were enrolled consecutively. Liver biopsies were performed in all patients with chronic viral hepatitis. NAFLD patients had either grade 2 or grade 3 steatosis on ultrasonography and elevated liver enzymes above the upper normal limits. Serum endocan levels were assessed from blood samples obtained at admission. Results: Gender distribution was similar among the groups (p=0.056). The mean age of the CHB patients was 45.8±12.1, CHC patients was 55.0±12.8 years, NAFLD patients was 42.8±10.8, while control group was 39.4±13.6 years old. Patients with CHC were older than all the others (p=0.001). Serum endocan levels were statistically significantly lower in CHB, CHC and NAFLD groups when compared with controls. Although levels of endocan were lower in CHB and CHC groups when compared with NAFLD group, the difference was not statistically significant. Conclusion: Serum endocan concentrations decrease in patients with liver disease. Unlike previous studies, we showed a negative correlation between endocan levels and inflammation stage of chronic hepatitis. However, further studies are needed to establish the association between endocan levels, liver fibrosis and hepatic inflammation. PMID:25126183

  4. Non-alcoholic fatty liver disease and subclinical atherosclerosis: A comparison of metabolically- versus genetically-driven excess fat hepatic storage.

    PubMed

    Di Costanzo, Alessia; D'Erasmo, Laura; Polimeni, Licia; Baratta, Francesco; Coletta, Paola; Di Martino, Michele; Loffredo, Lorenzo; Perri, Ludovica; Ceci, Fabrizio; Montali, Anna; Girelli, Gabriella; De Masi, Bruna; Angeloni, Antonio; Catalano, Carlo; Maranghi, Marianna; Del Ben, Maria; Angelico, Francesco; Arca, Marcello

    2017-02-01

    Non-alcoholic fatty liver disease (NAFLD) is frequently associated with atherosclerosis. However, it is unclear whether this association is related to excess fat liver storage per se or to metabolic abnormalities that typically accompany NAFLD. To investigate this, we compared individuals with hepatic steatosis driven by metabolic disturbances to those with hepatic steatosis associated with the rs738409 GG genotype in the patatin-like phospholipase domain-containing 3 gene (PNPLA3). Carotid intima-media thickness (CIMT), as a surrogate marker of subclinical atherosclerosis, was measured in 83 blood donors with the mutant GG genotype (group G), 100 patients with features of metabolic syndrome (MetS) but the wildtype CC genotype (group M), and 74 blood donors with the wildtype CC genotype (controls). Fatty liver was evaluated by ultrasonography and hepatic fat fraction (HFF) was measured using magnetic resonance (MRS/MRI) in 157 subjects. Compared with group G and controls, group M subjects were older and had increased adiposity indices, dyslipidemia, insulin resistance and elevated transaminase levels (all p < 0.05). They also had a more fatty liver on both ultrasonography and MRS/MRI. After adjustment for confounders (including severity of hepatic steatosis), the median CIMT in group M (0.84 [0.70-0.95] mm) was significantly greater than that in group G (0.66 [0.55-0.74] mm; p < 0.001), which was similar to that in controls (0.70 [0.64-0.81] mm). Results were similar in the subgroup evaluated using MRS/MRI. Excess liver fat accumulation appeared to increase the burden of subclinical atherosclerosis only when it is associated with metabolic abnormalities. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Effects of D-002, a mixture of high molecular weight beeswax alcohols, on patients with nonalcoholic fatty liver disease.

    PubMed

    Illnait, José; Rodríguez, Iván; Mendoza, Sarahí; Fernández, Yolanda; Mas, Rosa; Miranda, Mirtha; Piñera, Jesús; Fernández, Julio César; Mesa, Meilis; Fernández, Lilia; Carbajal, Daisy; Gámez, Rafael

    2013-07-01

    Nonalcoholic fatty liver disease (NAFLD) is intimately related to insulin resistance and ranges from a benign course to liver fibrosis and cirrhosis. NAFLD management mainly involves dietary modification and weight loss. Although no fully successful pharmacological intervention is available, alternative therapies to treat NAFLD have shown promising results. Experimental studies have shown that D-002, a mixture of beeswax alcohols with antioxidant effects, is hepatoprotective. The aim of this study was to investigate the efficacy and safety of D-002 in patients with NALFD. Fifty patients with NAFLD were randomized to receive a placebo or D-002 (100 mg/day) for 24 weeks. The primary endpoint was a significant ultrasonography-detected reduction of liver fat infiltration versus a placebo. Secondary endpoints were decreases in the homeostatic model assessment (HOMA) index, insulin levels, serum liver enzymes, increases in plasma total antioxidant status (TAS) and improved clinical symptoms versus the placebo recipients. At randomization, all indicators were comparable in both groups. At study completion, seven (28.0%) D-002-patients, but none of the placebo recipients, exhibited a normal liver echo pattern on ultrasonography (p < 0.01). Also, D-002 significantly reduced (p < 0.01 vs. baseline and placebo) the HOMA index and insulin levels and increased the TAS, but did not affect other parameters. The proportion of D-002-patients (12/25, 48.0%) showing symptom improvement was higher (p < 0.001) than that of the placebo group (1/25, 4.0%). The treatment was safe and well tolerated. Three patients in each group withdrew from the study. D-002 (100 mg/day) improved ultrasonographic findings, indicators of insulin resistance, plasma TAS and clinical evolution on NAFLD patients. Further studies, however, are needed to confirm these results.

  6. Ultrasonography of hydronephrosis in the newborn: a practical review

    PubMed Central

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  7. [Surgical aspects of liver resection based on 5 years' data].

    PubMed

    Fabri, M; Nikolić, V; Pfau, J; Vukobratov, V; Obradović, J; Petrović, P

    1994-01-01

    From 1988 to 1993 thirty liver resections were performed in thirty patients. Eight were operated for suffering from hepatocellular carcinoma, four from metastasis of colon's adenocarcinoma, five for great hemangiomas and the rest for focal liver changes. Right lobectomy was performed in six cases, as well as two trisegmentectomies and two left lobectomies while segmentectomies in the rest. Periopretive mortality occurred in two cases as two patients died because of postoperative thrombosis of vena portae and massive gastrointestinal bleeding. Recidive of malignant tumors was established in five patients after year and in other five till the second year. Benign tumors are without recidives. Later resection is a safe procedure with a considerable selection of patients, with use of latest technical conveniences, application of grafts on branches of vena portae and with routine application of intraoperative ultrasonography. The paper contains diagnostical postulates, surgical techniques and anatomic and morphologic types of resection.

  8. Abdominal Subcutaneous Fat Thickness Measured by Ultrasonography Correlates with Hyperlipidemia and Steatohepatitis in Obese Children.

    PubMed

    Lee, Sung Hyun; Kim, Dongwan; Baek, Min Young; Tchah, Hann; Kim, Yeon Sun; Ryoo, Eell; Kim, Yun Mi

    2015-06-01

    The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured 2.9±0.8 cm and 1.9±0.7 cm in the normal group, 3.3±0.8 cm and 2.0±0.7 cm in grade I, 3.8±0.8 cm and 2.3±0.8 cm in grade II, and 4.1±0.8 cm and 2.8±1.4 cm in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (p<0.01). In addition, abdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (p<0.01). Abdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.

  9. Ultrasonography in the preoperative difficult airway assessment.

    PubMed

    Fulkerson, Justin S; Moore, Heather M; Anderson, Tristan S; Lowe, Robert F

    2017-06-01

    To evaluate the utility of ultrasound for detection of the difficult intubation in a preoperative setting. PubMed, Ovid, CINAHL Plus Full Text, and Google Scholar searches using ["difficult airway" OR "difficult intubation" OR "difficult laryngoscopy" OR "difficult ventilation"] AND [ultrasonography OR sonography OR ultrasound] without date limitations. Abstracts without publications, case reports, letters, textbooks, unrelated topics, or foreign language articles were excluded. Ancestry references were included from the reviewed articles. Two reviewers independently performed the query. Each study was reviewed using the STARD checklist to assess blinding, incomplete data reporting, subject attrition, and selection of appropriate statistical tests. Ten studies were included. All used convenience sampling of adult subjects requiring direct laryngoscopy in elective surgical settings. One study is retrospective and nine are prospective observational. Populations included non-obese, obese, pregnant, and thyroidectomy patients in the United States, Turkey, Israel, Canada, Portugal, and China. Airway locations scanned are variable using different protocols and patient positioning. The outcome variable is uniformly the Cormack-Lehane Grade. 114 of the 681 total subjects had difficult laryngoscopies. Significance for sonographic prediction of difficult laryngoscopy occurred at three locations: hyomental distance [52.6 ± 5.8 mm (p < 0.01)], anterior tissue at the hyoid bone [16.9 mm (95 % CI 11.9-21.9) and 15.9 ± 2.7 mm (p < 0.0001)], and the thyrohyoid membrane [34.7 mm (95 % CI 28.8-40.7) and 23.9 ± 3.4 mm (p < 0.0001) and 28.25 ± 4.43 mm (p < 0.001)]. The vocal cords and sternal notch levels have conflicting significance. Limitations include the heterogeneous populations and lack of standard scanning protocols.

  10. Side-to-side cavocavostomy in adult piggyback liver transplantation.

    PubMed

    Pisaniello, D; Marino, M G; Perrella, A; Russo, F; Campanella, L; Marcos, A; Cuomo, O

    2012-09-01

    Our objective was to perform a retrospective study that described the anastomosis technique as well as the complications of side-to-side cavo-caval reconstruction. From June 1998 to April 2011, we performed 284 liver transplantations including 10 adults with live donor organs. In all cases but 2 (272), cavo-caval reconstruction was performed using side-to-side cavo-caval (STSCC) anastomosis. In 19 cases (6.9%), we also carried out an end-to-side temporary porto-caval shunt (TPCS). In 17 cases (6.2%) the technique was performed for retransplantation. STSCC anastomosis was technically feasible in all but 2 cases, regardless of the recipient's vena cava, anatomic factors, or graft size. Mean operative time for the STSCC was 13 minutes (range, 6-25). Routine Doppler ultrasonography was performed intraoperatively at the end of the surgery. There was no case of cava stump thrombosis. Complications associated with this technique were limited to 2 patients. One complication was torsion due to donor graft/recipient mismatch, which was successfully treated surgically by falciform ligament fixation. The second complication was only evident by sinusoidal congestion and was managed nonoperatively. Seventeen cases were uneventful for retransplant recipients. STSCC during piggyback liver transplantation is safe and can be performed in the retransplantation setting, with a low incidence of venous outflow obstruction that can be associated with the traditional piggyback technique. Our data suggest that donor graft to recipient mismatch is not an absolute contraindication when proper body size match is considered. A wide anastomosis with typical recipient hepatic vein inclusion is warranted with routine postanastomotic Doppler ultrasonography. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Microvascular autonomic dysfunction may justify false-positive stress myocardial perfusion imaging in patients with liver cirrhosis undergoing liver transplantation.

    PubMed

    Senzolo, M; Bassanello, M; Graziotto, A; Zucchetta, P; Cillo, U; Maraglino, G; Loreno, M; Bellotto, F; Davià, G; Burra, P

    2008-01-01

    Up to 15% of liver transplant candidates have asymptomatic coronary artery diseases, which increase the risk of cardiac complications during and after transplantation. The aim of this study was to prospectively investigate the usefulness of an integrated cardiological approach in cirrhotic patients undergoing liver transplantation. Twenty-four consecutive patients undergoing evaluation for liver transplantation were studied by assessing risk factors for coronary artery diseases, electrocardiogram with QTc interval determination, chest X-ray, echocardiography, 24-hour Holter monitor, myocardial perfusion scintigraphy (99mTc)MIBI-GSPECT at rest and after dipyridamole infusion. Cardiac (123)I-metaiodobenzylguanidine (MIBG) scan and coronarography were performed in patients with myocardial perfusion defects. Twenty three of 24 patients underwent successful liver transplantation; one patient died on the waiting list. Before liver transplantation, 29% of patients were diabetic and 41% were smokers. Eleven of 24 patients had a prolonged QTc interval, and 3/24 had positive myocardioscintigraphy after dipyridamole infusion: in two coronarography was negative, while the (123)I-MIBG washout was altered. No cardiac events were recorded during the short-and long-term follow-up after surgery. Predictive value of positive cardiac (99mTc)MIBI-GSPECT in patients with liver cirrhosis is low, and this may be due to alterations of cardiac microvascular tone as showed by cardiac (123)I-MIBG scan.

  12. Prevalence of and risk factors for gallbladder polyps detected by ultrasonography among healthy Chinese: analysis of 34 669 cases.

    PubMed

    Lin, Wey-Ran; Lin, Deng-Yn; Tai, Dar-In; Hsieh, Sen-Yung; Lin, Chun-Yen; Sheen, I-Shyan; Chiu, Cheng-Tang

    2008-06-01

    Gallbladder (GB) polyps are tumor or tumor-like projections arising from GB mucosa. Although most polyps are benign, some early GB carcinomas present as polypoid lesions. The diagnosis of GB polyps is relatively easy by ultrasonography. Although numerous studies have investigated GB polyps, few studies have addressed the prevalence of and factors associated with GB polyps for specific ethnic populations. This study analyzes the prevalence and factors associated with GB polyps in a Chinese population who can afford a paid general checkup. The prevalence of and risk factors for GB polyps diagnosed by ultrasonography were retrospectively investigated in 34 669 Chinese patients who underwent a general checkup at Chang Gung Memorial Hospital (Taipei, Taiwan) between 2000 and 2003. Demographic, hemogram, serum biochemistry, hepatitis B surface antigen, hepatitis C antibody, and ultrasonography study data was available for all the patients. The correlations between the prevalence of GB polyps and age, sex, body height, body weight, body mass index, hemogram, serum biochemistry, and viral markers were examined for all the patients. Excluding the patients who underwent cholecystectomy, the overall prevalence of GB polyps was 9.5% and highest for middle-aged males. The analyzed risk factors with increased odds ratios (OR) for the development of GB polyps were male sex (OR 0.646, P < 0.0005) and hepatitis B virus surface antigen positivity (OR 1.113, P < 0.0005). Other demographic characteristics and biochemical parameters, including body height, body weight, body mass index, lipid profile, chronic hepatitis C virus infection, and liver function did not correlate with the presence of GB polyps. The prevalence of GB polyps among the Chinese in this study is higher than that reported for other populations. Chinese males and other patients with chronic hepatitis B viral infections have a high risk for developing GB polyps.

  13. Association between Helicobacter pylori and liver-to-spleen ratio: a randomized-controlled single-blind study.

    PubMed

    Doğan, Zeynal; Filik, Levent; Ergül, Bilal; Sarikaya, Murat; Akbal, Erdem

    2013-01-01

    Helicobacter pylori infection is reported to be associated with some extragastrointestinal manifestations, such as hematological diseases (thrombocytopenia, anemia), obesity, and fatty liver disease. The length or the volume ratio of liver to spleen was suggested to be changed in some hematological and hepatobiliary disorders. We hypothesized that the liver-to-spleen ratio may be affected in H. pylori-positive patients. In this respect, we aimed to evaluate the effect of H. pylori infection on the liver-to-spleen ratio and platelet indices. A total of 174 patients with functional dyspepsia were included in the study. Patients were divided into group 1 (H. pylori-positive gastritis) (n=95) and group 2 (H. pylori negative, control group) (n=79). Liver, spleen length measurement, and liver steatosis scores were performed by ultrasonography by the same physicians who were blinded to the H. pylori results. Blood count values including the platelet count and the mean platelet volume (MPV) were compared between the two groups. BMI was also evaluated as a potential confounding factor for fatty liver. The liver-to-spleen ratio, platelet-to-spleen ratio, MPV-to-spleen ratio, and the MPV-to-liver ratio were significantly lower in the H. pylori-positive group compared with the H. pylori-negative group (P<0.001, <0.001, <0.001, and 0.038, respectively). Fatty liver was significantly more frequent in H. pylori-positive patients. Liver-to-spleen ratio and the MPV-to-spleen ratio are important indices in the pathogenesis of H. pylori-linked liver and spleen manifestations, and thrombocytopenia.

  14. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    PubMed

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  15. Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?

    PubMed

    Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P

    2015-09-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the

  16. Evaluation of clinical breast examination and breast ultrasonography among pregnant women in Abakaliki, Nigeria

    PubMed Central

    Ezeonu, Paul Olisaemeka; Ajah, Leonard Ogbonna; Onoh, Robinson Chukwudi; Lawani, Lucky Osaheni; Enemuo, Vincent Chidi; Agwu, Uzoma MaryRose

    2015-01-01

    Background Breast cancer in pregnancy accounts for 2%–3% of all breast cancers. The increased vascularity and lymphatic drainage from the breast during pregnancy potentiate the metastatic spread of the cancer to the regional lymph nodes. However, the increased breast density in pregnancy makes it difficult to detect breast lesions early. Aim To evaluate and compare the detection rate of breast lesions using clinical breast examination (CBE) and breast ultrasonography among pregnant women. Methodology A cross-sectional comparative study involving antenatal clinic attendees at the Federal Teaching Hospital, Abakaliki, was conducted between March 3, 2014, and December 31, 2014. CBE and breast ultrasonography were done in the participants at booking and repeated at 6 weeks postpartum. Fine-needle aspiration cytology and histology were done in women with suspicious breast lesions on CBE or breast ultrasonography or both. Data analysis was both descriptive and inferential at the 95% confidence level using the Statistical Package for the Social Sciences (SPSS) software version 17.0. Test of significance was done using chi-square test. A P-value of less than or equal to 0.05 was considered statistically significant. Results A total of 320 pregnant women participated in the study. Of these, 267 (83.4%) were aware of breast cancer. Although more lesions were detected with breast ultrasonography than by CBE, there was no statistically significant difference between them (25 versus 17; P=0.26). The histology of the lesions revealed 21 benign lesions and 4 normal breast tissues. The sensitivity of breast ultrasonography was 95.2%, while that of CBE was 66.7%. The specificity, positive predictive value, and negative predictive value were similar between CBE and breast ultrasonography. Conclusion The detection rates of breast lesions by both CBE and breast ultrasonography were equivalent during pregnancy and 6 weeks postpartum, making CBE a convenient and very cost

  17. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  18. Laparoscopic thermoablation of colorectal cancer metastases to the liver – new experience of the centre

    PubMed Central

    Spychała, Arkadiusz; Lewandowski, Adam; Nowaczyk, Piotr

    2012-01-01

    Aim of the study Thermoablation of metastatic lesions in the liver is very commonplace. At present there are 3 essential techniques of access to carry out the procedure: open surgery, percutaneous technique and laparoscopic method. Percutaneous thermoablation is criticised due to the possible lack of radicalism. On the other hand, thermoablation during open surgery is a big perioperative trauma for the patient. The laparoscopic technique seems to be a compromise between the aforementioned techniques. The aim of this study was to present the technique and preliminary results of thermoablation of the liver carried out by means of the laparoscopic technique. Material and methods Laparoscopic thermoablation was carried out in 4 patients with colorectal cancer metastases to the liver. In order to precisely locate the tumour and guarantee radicalism of the surgery, laparoscopic probe ultrasonography was carried out during the procedure. Results All the patients underwent the procedure without any difficulties. All the patients left the hospital department as soon as 3 or 4 days after the surgery. This was about 7 days earlier in comparison with the open surgery procedure, which had been carried out before. The patients required a supply of analgesics only during the first 48 hours – non-steroid anti-inflammatory drugs, which made a substantial difference between them and the patients treated with the open surgical technique. Thanks to the laparoscopic ultrasound technique one patient had an additional lesion located, which had not been described in preoperative examinations. Conclusions In combination with ultrasonography, laparoscopic access, which does not have a very invasive character, seems to be relatively simple and effective to carry out the procedure of thermoablation. PMID:23788874

  19. Docosahexaenoic acid for the treatment of fatty liver: randomised controlled trial in children.

    PubMed

    Nobili, V; Alisi, A; Della Corte, C; Risé, P; Galli, C; Agostoni, C; Bedogni, G

    2013-11-01

    Non-alcoholic fatty liver disease (NAFLD) is the most common liver disease in children. We tested whether dietary supplementation with docosahexaenoic acid (DHA) can decrease liver fat content in children with NAFLD. We performed a randomized controlled trial of DHA supplementation (250 mg/day and 500 mg/day) vs. placebo in 60 children with NAFLD (20 children per group). The main outcome was the change in liver fat as detected by ultrasonography after 6, 12, 18 and 24 months of treatment. Secondary outcomes were changes in triglycerides, alanine transaminase (ALT), body mass index (BMI) and homeostasis model assessment of insulin resistance (HOMA). The odds of more severe versus less severe liver steatosis decreased to the same degree at 6 months in children treated with DHA 250 mg/day and DHA 500 mg/day vs. placebo and persisted virtually unmodified for 24 months (OR ≤ 0.02, p ≤ 0.05 for all time points). Triglycerides were lower in the DHA groups than in the placebo group at any time point and ALT was lower in these groups from month 12 onwards. HOMA was lower in the DHA 250 mg group vs. placebo at months 6 and 12. DHA supplementation improves liver steatosis in children with NAFLD. Doses of 250 mg/day and 500 mg/day of DHA appear to be equally effective in reducing liver fat content. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Follow-up of renal and mesenteric artery revascularization with duplex ultrasonography

    PubMed Central

    Taylor, David C.; Houston, Gordon T.M.; Anderson, Caroline; Jameson, Margot; Popatia, Shelley

    1996-01-01

    Objective To evaluate the long-term anatomic results of renal revascularization procedures using duplex ultrasonography. Design A case series. Setting A university-affiliated hospital. Patients Twenty-five patients who had undergone renal percutaneous transluminal angioplasty (PTA) (18 arteries), renal bypass (10 arteries) and mesenteric bypass (6 arteries). The mean follow-up was 22 months (range from 3 to 48 months) for those who underwent renal PTA, 23 months (range from 1.5 to 70 months) for those who underwent renal bypass and 34 months (range from 8 to 144 months) for those who underwent mesenteric bypass. Main Outcome Measures Patency rates for the three procedures as assessed by duplex ultrasonography. Results Duplex ultrasonography demonstrated patency without stenosis after renal and mesenteric artery revascularization in 14 arteries subjected to renal PTA, 9 arteries subjected to renal bypass and 6 arteries subjected to mesenteric bypass. Three arteries that had renal PTA had recurrent vessel stenosis and one had occlusion. One artery that had renal bypass showed occlusion. Conclusions Renal PTA, renal bypass and mesenteric bypass are durable procedures at 2 years of follow-up, and duplex ultrasonography is a valuable method for assessing the patency of arteries after renal and mesenteric revascularization. PMID:8599785

  1. Validation of ultrasonography of the thyroid gland for epidemiological purposes.

    PubMed

    Knudsen, N; Bols, B; Bülow, I; Jørgensen, T; Perrild, H; Ovesen, L; Laurberg, P

    1999-11-01

    Ultrasonography of the thyroid is often used in epidemiological surveys, thus thorough characterization of the interobserver variation of the different parameters obtained is important. Various methods have been used for measuring thyroid volume, and different formulas have been used for calculation of thyroid volume from the measured dimensions. In this article, two principles of thyroid volume measurement are described in detail: the wellknown method based on the three axes of each lobe and a new principle based on planimetry in two planes. The interobserver variation of the examination and the measuring procedure in itself were tested on 25 participants in a population study. A comparison of postmortem ultrasonography of the thyroid and results of an autopsy was performed. Good correlation and agreement between observers was found for thyroid volume (r = 0.98) and prevalence of thyroid nodules (kappa = 0.72), whereas echogenecity and echopattern showed little agreement. The correlation of thyroid volume by ultrasonography to autopsy results was satisfactory (r = 0.93), but the volume tended to be slightly underestimated even when using the formula pi/6(= 0.52)*length*width*depth. No major differences were found between the performance of the two principles of volume calculation. We conclude that when the measuring procedure is well defined, results of ultrasonography are comparable between observers for thyroid volume and prevalence of thyroid nodules, but not for echogenecity or echopattern. The formula of length*depth*width*pi/6 is suitable for thyroid volume measurement.

  2. Portable ultrasonography in mass casualty incidents: The CAVEAT examination.

    PubMed

    Stawicki, Stanislaw Peter; Howard, James M; Pryor, John P; Bahner, David P; Whitmill, Melissa L; Dean, Anthony J

    2010-11-18

    Ultrasonography used by practicing clinicians has been shown to be of utility in the evaluation of time-sensitive and critical illnesses in a range of environments, including pre-hospital triage, emergency department, and critical care settings. The increasing availability of light-weight, robust, user-friendly, and low-cost portable ultrasound equipment is particularly suited for use in the physically and temporally challenging environment of a multiple casualty incident (MCI). Currently established ultrasound applications used to identify potentially lethal thoracic or abdominal conditions offer a base upon which rapid, focused protocols using hand-carried emergency ultrasonography could be developed. Following a detailed review of the current use of portable ultrasonography in military and civilian MCI settings, we propose a protocol for sonographic evaluation of the chest, abdomen, vena cava, and extremities for acute triage. The protocol is two-tiered, based on the urgency and technical difficulty of the sonographic examination. In addition to utilization of well-established bedside abdominal and thoracic sonography applications, this protocol incorporates extremity assessment for long-bone fractures. Studies of the proposed protocol will need to be conducted to determine its utility in simulated and actual MCI settings.

  3. Ultrasonography of the equine shoulder: technique and normal appearance.

    PubMed

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  4. [Pancreatic ultrasonography].

    PubMed

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  5. Ultrasonography of ovarian hyperandrogenemia

    NASA Astrophysics Data System (ADS)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  6. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    PubMed

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography.

    PubMed

    Kim, Kwang Baek; Kim, Chang Won

    2015-01-01

    Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.

  8. Prevalence and determinants of biochemical dysfunction of the liver in Atayal Aboriginal community of Taiwan: Is betel nut chewing a risk factor?

    PubMed Central

    Lin, Ching-Feng; Shiau, Tun-Jen; Ko, Ying-Chin; Chen, Ping-Ho; Wang, Jung-Der

    2008-01-01

    Background We address the independent and interactive roles of habitual betel quid chewing and other known risk factors for biochemical dysfunction and cirrhosis of the liver. Methods To determine the prevalence rates and risk factors associated with biochemical dysfunction of the liver, a total of 3,010 adult residents in an Atayal Aboriginal community were invited to participate in the study. Abdominal ultrasonography was used to diagnose liver cirrhosis. Results There were 2,063 Atayal Aboriginal and 947 non-Aboriginal in this study. The result showed overall prevalence rates for hepatitis B surface antigen (HBsAg) and hepatitis C virus (HCV) were 21.2 % and 2.9 %, respectively. There were 16.5 %, 15.1 % and 22.4 % subjects with abnormal alanine aminotransferase (ALT), aspartate aminotransferase (AST), and gamma glutamyl transpeptidase (GGT), accordingly. Multiple logistic regression analysis showed that combined infections with HBV and HCV presented with the highest risks with OR (odds ratio) and 95% CI (confidence interval) of 4.2 (1.2–17.4) and 3.8 (1.0–14.1), respectively for elevation of ALT and AST; followed by alcohol (1.7 and 3.1), male gender (1.7 and 1.6), betel quid (1.5 and 1.3), smoking (1.4 and 1.8), and aboriginal (1.4 and 1.3). There is effect-measure modification between viral infection and betel quid chewing for increased severity of abnormal ALT elevation. Among 1,382 subjects consenting to abdominal ultrasonography, 41(3.0%) were found to have liver cirrhosis with the same factors associated with higher risks. Conclusion In addition to infections with viral hepatitis B and/or C, we found Atayal Aboriginal, males, current smokers, drinkers and betel quid chewers were independently associated with biochemical dysfunction and probably cirrhosis of the liver. Further study is needed to corroborate the above hypothesis. PMID:18439308

  9. Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions

    PubMed Central

    Srinivasa Babu, Aparna; Wells, Michael L.; Teytelboym, Oleg M.; Mackey, Justin E.; Miller, Frank H.; Yeh, Benjamin M.; Ehman, Richard L.

    2016-01-01

    Chronic liver disease has multiple causes, many of which are increasing in prevalence. The final common pathway of chronic liver disease is tissue destruction and attempted regeneration, a pathway that triggers fibrosis and eventual cirrhosis. Assessment of fibrosis is important not only for diagnosis but also for management, prognostic evaluation, and follow-up of patients with chronic liver disease. Although liver biopsy has traditionally been considered the reference standard for assessment of liver fibrosis, noninvasive techniques are the emerging focus in this field. Ultrasound-based elastography and magnetic resonance (MR) elastography are gaining popularity as the modalities of choice for quantifying hepatic fibrosis. These techniques have been proven superior to conventional cross-sectional imaging for evaluation of fibrosis, especially in the precirrhotic stages. Moreover, elastography has added utility in the follow-up of previously diagnosed fibrosis, the assessment of treatment response, evaluation for the presence of portal hypertension (spleen elastography), and evaluation of patients with unexplained portal hypertension. In this article, a brief overview is provided of chronic liver disease and the tools used for its diagnosis. Ultrasound-based elastography and MR elastography are explored in depth, including a brief glimpse into the evolution of elastography. Elastography is based on the principle of measuring tissue response to a known mechanical stimulus. Specific elastographic techniques used to exploit this principle include MR elastography and ultrasonography-based static or quasistatic strain imaging, one-dimensional transient elastography, point shear-wave elastography, and supersonic shear-wave elastography. The advantages, limitations, and pitfalls of each modality are emphasized. ©RSNA, 2016 PMID:27689833

  10. Klebsiella pneumoniae liver abscess and endophthalmitis

    PubMed Central

    Abdul-Hamid, Ayeshah; Bailey, Sarah-Jane

    2013-01-01

    A 36-year-old man was referred to the general medical team with endophthalmitis. He was noted to have raised inflammatory markers and deranged liver function tests on admission. Subsequent abdominal ultrasound scan revealed a liver abscess requiring percutaneous drainage. A common human pathogen, Klebsiella pneumoniae, was cultured from multiple sites. K pneumoniae has virulent serotypes (K1 and K2) that can cause primary liver abscess with metastatic infections. Cases have previously been predominantly reported in Southeast Asia but are increasing in prevalence in Europe and North America. The main known risk factor for the disease is diabetes mellitus. Swift antibiotic therapy, ophthalmology review and percutaneous drainage of any liver abscess are essential. Early recognition of the syndrome, despite potentially few initial symptoms, can significantly reduce morbidity and mortality. The authors report the first recorded case of K pneumoniae liver abscess with endophthalmitis in the UK. PMID:23559652

  11. Is intravenous urography required when ultrasonography and KUB evidence a ureteroscopy plan?

    PubMed

    Aghamir, Seyed Mohammad Kazem; Modaresi, Seyed Saeed; Salavati, Alborz; Aloosh, Mehdi; Meysami, Ali Pasha

    2012-01-01

    To determine whether pre-ureteroscopic stone extraction (USE) evaluation by intravenous urography (IVU) can change the clinical decision made on the basis of a plain X-ray of the kidneys, ureters, and bladder (KUB) plus an ultrasonography in the case of ureteral calculi. From October 2005 to November 2007, 139 USE candidates were selected based on ultrasonography and KUB, and were randomly divided into two groups. Each group was assessed by an expert urologist to decide about the treatment plans. Thereafter, all the patients underwent an IVU pre-operatively and were evaluated for the second time by the other urologist considering IVU. Presence of a hydronephrotic kidney on the ultrasonography, existence of a density in the probable tract of the ureter on KUB, and previous episodes of renal colic were considered as inclusion criteria. Exclusion criteria were non-opaque stones on KUB, hypersensitivity to contrast media, and serum creatinine > 1.5 mg/dL. On the basis of ultrasonography and KUB assessment, all of the patients were identified candidate for USE. According to secondary IVU-based planning, of 139 patients, 127 (91.3%) required USE, 10 (7.1%) ureteroscopy, and 2 (1.4%) non-operative treatment. About 8.7% of treatment plans was changed by IVU, which was not statistically significant (P = .35). Positive predictive value of ultrasonography plus KUB to diagnose a ureteral stone which needed USE was 92.8% while IVU is the gold standard (95% confidence interval: 92.38 to 93.22). Intravenous urography is not useful enough to be performed routinely before entire USEs.

  12. Further exploration of MRI techniques for liver T1rho quantification.

    PubMed

    Zhao, Feng; Yuan, Jing; Deng, Min; Lu, Pu-Xuan; Ahuja, Anil T; Wang, Yi-Xiang J

    2013-12-01

    With biliary duct ligation and CCl4 induced rat liver fibrosis models, recent studies showed that MR T1rho imaging is able to detect liver fibrosis, and the degree of fibrosis is correlated with the degree of elevation of the T1rho measurements, suggesting liver T1rho quantification may play an important role for liver fibrosis early detection and grading. It has also been reported it is feasible to obtain consistent liver T1rho measurement for human subjects at 3 Tesla (3 T), and preliminary clinical data suggest liver T1rho is increased in patients with cirrhosis. In these previous studies, T1rho imaging was used with the rotary-echo spin-lock pulse for T1rho preparation, and number of signal averaging (NSA) was 2. Due to the presence of inhomogeneous B0 field, artifacts may occur in the acquired T1rho-weighted images. The method described by Dixon et al. (Magn Reson Med 1996;36:90-4), which is a hard RF pulse with 135° flip angle and same RF phase as the spin-locking RF pulse is inserted right before and after the spin-locking RF pulse, has been proposed to reduce sensitivity to B0 field inhomogeneity in T1rho imaging. In this study, we compared the images scanned by rotary-echo spin-lock pulse method (sequence 1) and the pulse modified according to Dixon method (sequence 2). When the artifacts occurred in T1rho images, we repeated the same scan until satisfactory. We accepted images if artifact in liver was less than 10% of liver area by visual estimation. When NSA =2, the breath-holding duration for data acquisition of one slice scanning was 8 sec due to a delay time of 6,000 ms for magnetization restoration. If NSA =1, the duration was shortened to be 2 sec. In previous studies, manual region of interest (ROI) analysis of T1rho map was used. In this current study, histogram analysis was also applied to evaluate liver T1rho value on T1rho maps. MRI data acquisition was performed on a 3 T clinical scanner. There were 29 subjects with 61 examinations obtained

  13. Use of ultrasonography to make management decisions

    USDA-ARS?s Scientific Manuscript database

    Transrectal ultrasonography has been available for making management decisions since the mid 1980’s. This technology allows for the real-time visualization of internal structures (i.e. ovary and fetus) that are otherwise difficult to evaluate. The use of this technology in making reproductive manag...

  14. [Correlation of liver stiffness measured by FibroTouch and FibroScan with Ishak fibrosis score in patients with chronic hepatitis B].

    PubMed

    Chen, G F; Ping, J; Gu, H T; Zhao, Z M; Zhou, Y; Xing, F; Tao, Y Y; Mu, Y P; Liu, P; Liu, C H

    2017-02-20

    Objective: To investigate the correlation of liver stiffness measured by FibroTouch (FT) and FibroScan (FS) with Ishak fibrosis score in patients with chronic hepatitis B. Methods: A total of 313 patients with chronic hepatitis B who visited Department of Liver Cirrhosis in Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine from November 2014 to May 2016 were enrolled. All the patients underwent liver biopsy, and FT and FS were used to determine liver stiffness measurement (LSM). Serum biochemical parameters were measured, and the aspartate aminotransferase-to-platelet ratio index (APRI) in a multi-parameter model of liver fibrosis and fibrosis-4 (FIB-4) index were calculated. The consistency between the results of four noninvasive examinations and Ishak fibrosis score was compared. The t-test was used for comparison of LSM determined by FT and FS. Pearson correlation analysis was used investigate the correlation between LSM determined by FT and FS; Spearman correlation analysis was used to investigate the correlation of serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels and Knodell score with LSM determined by FT and FS; the correlation between LSM determined by FT and FS and fibrosis stage was analyzed by partial correlation analysis adjusted by Knodell score for liver inflammatory activity; Spearman correlation analysis was used for APRI, FIB-4, and fibrosis stage. Based on the Ishak fibrosis score, the receiver operating characteristic (ROC) curve was used to analyze the values of four noninvasive methods in the diagnosis of liver fibrosis. Results: There was no significant difference in LSM measured by FT and FS in all patients (15.75±9.42 kPa vs 15.42±10.52 kPa, P > 0.05) and Pearson correlation analysis indicated a significant positive correlation between them ( r = 0.858, P < 0.01); serum ALT and AST levels and liver inflammatory activity were correlated with LSM determined by FT and FS. There

  15. Carotid artery Doppler ultrasonography in retinal macroaneurysms.

    PubMed

    Thurairajan, G; Potamitis, T; Naylor, G; Gibson, J

    1998-01-01

    It is postulated that retinal arterial macroaneurysms (RAMs) occur at the site of incomplete embolic occlusion of a branch retinal artery. Embolic events of the retinal vessels are related to the state of the carotid artery tree and therefore Doppler ultrasonography of the carotid arteries in these patients is of particular interest. We have examined 13 patients with retinal artery macroaneurysms with carotid artery Doppler ultrasonography (CADU). Eight of these patients (61.5%) exhibited atheromatous plaques on the same side as the RAM with a moderate degree of arterial narrowing. Although our group of patients did not show advanced carotid artery disease, alterations of the arterial wall found at the level of the carotid artery were higher than expected in a similar hypertensive population. To our knowledge this is the first study of the carotid arterial tree in these patients. Our results support the theory that RAMs may be of embolic origin. Furthermore they demonstrate that CADU is a useful investigation in patients with RAMs.

  16. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography

    PubMed Central

    Kim, Kwang Baek

    2015-01-01

    Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future. PMID:26247023

  17. [Color Doppler ultrasonography--a new imaging procedure in maxillofacial surgery].

    PubMed

    Reinert, S; Lentrodt, J

    1991-01-01

    Colour Doppler ultrasonography shows blood flow in real time and colour by combining the features of real time B mode ultrasound and Doppler. At each point in the image the returning signal is interrogated for both amplitude and frequency information. The resulting image shows all non-moving structures in shades of gray and moving structures in shades of red or blue depending on direction and velocity. The technique of colour Doppler ultrasonography and our experiences in 63 examinations are described. The clinical application of this new simple non-invasive method in maxillo-facial surgery is discussed.

  18. WE-E-BRB-00: Motion Management for Pencil Beam Scanning Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed.more » Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of

  19. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    PubMed

    Riteau, Anne-Sophie; Tassin, Mikael; Chambon, Guillemette; Le Vaillant, Claudine; de Laveaucoupet, Jocelyne; Quéré, Marie-Pierre; Joubert, Madeleine; Prevot, Sophie; Philippe, Henri-Jean; Benachi, Alexandra

    2014-01-01

    To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  20. Ultrasonography in gastroenterology.

    PubMed

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  1. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    PubMed

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  2. Diagnosis of Nipple Discharge: Value of Magnetic Resonance Imaging and Ultrasonography in Comparison with Ductoscopy.

    PubMed

    Yılmaz, Ravza; Bender, Ömer; Çelik Yabul, Fatma; Dursun, Menduh; Tunacı, Mehtap; Acunas, Gülden

    2017-04-05

    Pathologic nipple discharge, which is a common reason for referral to the breast imaging service, refers to spontaneous or bloody nipple discharge that arises from a single duct. The most common cause of nipple discharge is benign breast lesions, such as solitary intraductal papilloma and papillomatosis. Nevertheless, in rare cases, a malignant cause of nipple discharge can be found. To study the diagnostic value of ultrasonography, magnetic resonance imaging, and ductoscopy in patients with pathologic nipple discharge, compare their efficacy, and investigate the importance of magnetic resonance imaging in the diagnosis of intraductal pathologies. Diagnostic accuracy study. Fifty patients with pathologic nipple discharge were evaluated by ultrasonography and magnetic resonance imaging. Of these, 44 ductoscopic investigations were made. The patients were classified according to magnetic resonance imaging, ultrasonography, and ductoscopy findings. A total of 25 patients, whose findings were reported as intraductal masses, underwent surgery oincluding endoscopic excision for two endoscopic excision. Findings were compared with the pathology results that were accepted as the gold standard in the description of the aetiology of nipple discharge. In addition, magnetic resonance imaging, ultrasonography and ductoscopy findings were analysed comparatively in patients who had no surgery. Intraductal masses were reported in 26 patients, 20 of whom operated and established accurate diagnosis of 18 patients on magnetic resonance imaging. According to the ultrasonography, intraductal masses were identified in 22 patients, 17 of whom underwent surgery. Ultrasonography established accurate diagnoses in 15 patients. Intraductal mass was identified in 22 patients and ductoscopy established accurate diagnoses based on histopathologic results in 16 patients. The sensitivities of methods were 75% in ultrasonography, 90% in magnetic resonance imaging, and 94.6% in ductoscopy. The

  3. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function.

    PubMed

    Aziz, Farooq; Ihsan, Ayesha; Nazir, Aalia; Ahmad, Ishaq; Bajwa, Sadia Zafar; Rehman, Asma; Diallo, Abdoulaye; Khan, Waheed S

    2017-01-01

    Gold nanoparticles (GNPs) with dimension in the range of 1-100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs) and solid gold nanoparticles (SGNPs). PGNPs of size 35 nm were fabricated by reduction of gold (III) solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λ max 560 nm) and SGNPs (λ max 548 nm) were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU) than SGNPs (26 HU). To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV) injection including liver function profile, renal (kidney) function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as compared to SGNPs 6 hours after injection. Our findings suggested that the novel PGNPs enhance CT scan image with higher efficacy as compared to SGNPs. The results showed that IV administration of synthesized PGNPs increases the levels of aspartate aminotransferase (AST), alkaline phosphate (ALP), serum creatinine, and blood glucose, whereas that of SGNPs increases the levels of AST, ALP, and blood glucose.

  4. Prenatal diagnosis of placenta accreta by colour Doppler ultrasonography: 5-year review.

    PubMed

    Pongrojpaw, Densak; Chanthasenanont, Athita; Nanthakomon, Tongta; Suwannarurk, Komsun

    2014-08-01

    To determine the accuracy of colour Doppler ultrasonography to diagnose placenta accreta. The authors reviewed cases of placenta accreta between January, 2008 and December, 2012. Ultrasonographic images consistent with signs ofplacenta accreta (numerous vascular lacunae, loss ofsubplacentalsonolucent space, absent lower uterine segment between bladder-placenta, turbulent or complicated blood flow at the uteroplacental interface) were correlated with findings at the time of surgery and pathologic examination. Over 60 months, 12 cases (0.48/1,000 deliveries) with suspected placenta accreta by ultrasonography were studied. The median gestational age atfirst diagnosis was 24 weeks. All cases had at least one previous cesarean delivery. At surgery, all cases had an adherent placenta requiring hysterectomy (five accreta, three increta, andfourpercreta). Four cases (33%) had accidental tear of urinary bladder Nine cases (75%) required blood transfusions. Colour Doppler ultrasonography appears useful in antenatal diagnosis ofplacenta accreta.

  5. Liver perfusion imaging in patients with primary and metastatic liver malignancy: prospective comparison between 99mTc-MAA spect and dynamic CT perfusion.

    PubMed

    Reiner, Caecilia S; Goetti, Robert; Burger, Irene A; Fischer, Michael A; Frauenfelder, Thomas; Knuth, Alexander; Pfammatter, Thomas; Schaefer, Niklaus; Alkadhi, Hatem

    2012-05-01

    To prospectively analyze the correlation between parameters of liver perfusion from technetium99m-macroaggregates of albumin (99mTc-MAA) single photon emission computed tomography (SPECT) with those obtained from dynamic CT perfusion in patients with primary or metastatic liver malignancy. Twenty-five consecutive patients (11 women, 14 men; mean age 60.9 ± 10.8; range: 32-78 years) with primary (n = 5) or metastatic (n = 20) liver malignancy planned to undergo selective internal radiotherapy underwent dynamic contrast-enhanced CT liver perfusion imaging (four-dimensional spiral mode, scan range 14.8 cm, 15 scans, cycle time 3 seconds) and 99m)Tc-MAA SPECT after intraarterial injection of 180 MBq 99mTc-MAA on the same day. Data were evaluated by two blinded and independent readers for the parameters arterial liver perfusion (ALP), portal venous perfusion (PVP), and total liver perfusion (TLP) from CT, and the 99mTc-MAA uptake-ratio of tumors in relation to normal liver parenchyma from SPECT. Interreader agreements for quantitative perfusion parameters were high for dynamic CT (r = 0.90-0.98, each P < .01) and 99mTc -MAA SPECT (r = 0.91, P < .01). Significant correlation was found between 99mTc-MAA uptake ratio and ALP (r = 0.7, P < .01) in liver tumors. No significant correlation was found between 99mTc-MAA uptake ratio, PVP (r = -0.381, P = .081), and TLP (r = 0.039, P = .862). This study indicates that in patients with primary and metastatic liver malignancy, ALP obtained by dynamic CT liver perfusion significantly correlates with the 99mTc-MAA uptake ratio obtained by SPECT. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  6. Enhanced liver fibrosis test using ELISA assay accurately discriminates advanced stage of liver fibrosis as determined by transient elastography fibroscan in treatment naïve chronic HCV patients.

    PubMed

    Omran, Dalia; Yosry, Ayman; Darweesh, Samar K; Nabeel, Mohammed M; El-Beshlawey, Mohammed; Saif, Sameh; Fared, Azza; Hassany, Mohamed; Zayed, Rania A

    2018-02-01

    Evaluation of liver fibrosis stage is crucial in the assessment of chronic HCV patients, regarding decision to start treatment and during follow-up. Our aim was to assess the validity of the enhanced liver fibrosis (ELF) score in discrimination of advanced stage of liver fibrosis in naïve chronic HCV patients. We prospectively evaluated liver fibrosis stage in one hundred eighty-one naïve chronic HCV Egyptian patients by transient elastography (TE)-FibroScan. Patients were categorized into mild to moderate fibrosis (≤F2) group and advanced fibrosis (≥F3) group. The ELF score components, hyaluronic acid (HA), amino-terminal propeptide of type-III-procollagen (PIIINP) and tissue inhibitor of metalloproteinase type-1 (TIMP-1), were done using ELISA test. The mean values of ELF and its individual components significantly correlated with the hepatic fibrosis stage as measured by TE-FibroScan (P value 0.001). ELF cutoff value of 9.8 generated a sensitivity of 77.8%, specificity of 67.1%, area under the receiver operator characteristic curve (AUROC) of 0.76 with 95% confidence interval [CI] (0.68-0.83) for detecting advanced fibrosis (F ≥ 3). ELF panel is a good, reliable noninvasive test and showed comparable results to TE-FibroScan in detecting liver fibrosis stage in treatment naïve chronic HCV patients.

  7. Liver Volumetry Plug and Play: Do It Yourself with ImageJ

    PubMed Central

    Dello, Simon A. W. G.; van Dam, Ronald M.; Slangen, Jules J. G.; van de Poll, Marcel C. G.; Bemelmans, Marc H. A.; Greve, Jan Willem W. M.; Beets-Tan, Regina G. H.; Wigmore, Stephen J.

    2007-01-01

    Background A small remnant liver volume is an important risk factor for posthepatectomy liver failure and can be predicted accurately by computed tomography (CT) volumetry using radiologic image analysis software. Unfortunately, this software is expensive and usually requires support by a radiologist. ImageJ is a freely downloadable image analysis software package developed by the National Institute of Health (NIH) and brings liver volumetry to the surgeon’s desktop. We aimed to assess the accuracy of ImageJ for hepatic CT volumetry. Methods ImageJ was downloaded from http://www.rsb.info.nih.gov/ij/. Preoperative CT scans of 15 patients who underwent liver resection for colorectal cancer liver metastases were retrospectively analyzed. Scans were opened in ImageJ; and the liver, all metastases, and the intended parenchymal transection line were manually outlined on each slice. The area of each selected region, metastasis, resection specimen, and remnant liver was multiplied by the slice thickness to calculate volume. Volumes of virtual liver resection specimens measured with ImageJ were compared with specimen weights and calculated volumes obtained during pathology examination after resection. Results There was an excellent correlation between the volumes calculated with ImageJ and the actual measured weights of the resection specimens (r² = 0.98, p < 0.0001). The weight/volume ratio amounted to 0.88 ± 0.04 (standard error) and was in agreement with our earlier findings using CT-linked radiologic software. Conclusion ImageJ can be used for accurate hepatic CT volumetry on a personal computer. This application brings CT volumetry to the surgeon’s desktop at no expense and is particularly useful in cases of tertiary referred patients, who already have a proper CT scan on CD-ROM from the referring institution. Most likely the discrepancy between volume and weight results from exsanguination of the liver after resection. PMID:17726630

  8. Association of hepatic insulin resistance indexes to nonalcoholic fatty liver disease and related biomarkers.

    PubMed

    Sesti, G; Fiorentino, T V; Hribal, M L; Sciacqua, A; Perticone, F

    2013-12-01

    Nonalcoholic fatty liver disease (NAFLD) is linked with insulin resistance, however, if it is differentially associated with surrogate hepatic insulin resistance indexes is still undefined. We examined the relationship between these indexes, NAFLD and its related biomarkers (alanine aminotransferase [ALT], aspartate aminotransferase [AST], gamma-glutamyltransferase [GGT], alkaline phosphatase [ALK], high-sensitive C reactive protein [hsCRP], insulin-like growth factor-1 [IGF-1]). 473 Caucasians subjects underwent liver ultrasonography and oral glucose tolerance tests; homeostasis model assessment (HOMA), glucose(0-30) (area under the curve [AUC]) × insulin(0-30) (AUC) and liver insulin resistance (liver IR) indexes were computed. Liver IR index correlated more strongly than HOMA with GGT, ALK, hsCRP, ALT and AST and more strongly than glucose(0-30) (AUC) × insulin(0-30) (AUC) index with ALT, AST, GGT, ALK, hsCRP, and IGF-1. The ability of these indexes to identify NAFLD was evaluated by the area under the ROC curve; the ROC AUC for liver IR index was higher (0.733) than the ones for HOMA (0.685) and glucose(0-30) (AUC) × insulin(0-30) (AUC) (0.663) indexes. In a logistic regression model subjects in the highest quartile of the three indexes had a higher risk of having NAFLD than those in the lowest quartile (9.85-, 5.12- or 3.99-fold higher for liver IR index, HOMA, glucose(0-30) (AUC) × insulin(0-30) (AUC) index respectively). we documented significant cross-sectional associations of NAFLD and liver biomarkers with three validated indexes of hepatic insulin resistance, with liver IR index showing the stronger correlation. © 2013 Elsevier B.V. All rights reserved.

  9. Real-time elastography as a noninvasive assessment of liver fibrosis in chronic hepatitis C Egyptian patients: a prospective study.

    PubMed

    Mobarak, Lamiaa; Nabeel, Mohammed M; Hassan, Ehsan; Omran, Dalia; Zakaria, Zeinab

    2016-01-01

    Hepatitis C virus is a worldwide problem. Noninvasive methods for liver fibrosis assessment as ultrasound-based approaches have emerged to replace liver biopsy. The aim of this study was to evaluate the diagnostic accuracy of real-time elastography (RTE) in the assessment of liver fibrosis in patients with chronic hepatitis C (CHC), compared with transient elastography and liver biopsy. RTE, FibroScan and liver biopsy were performed in 50 CHC patients. In addition, aspartate aminotransferase to platelet ratio index (APRI) and routine laboratory values were included in the analysis. RTE was able to diagnose significant hepatic fibrosis (F ≥2) according to METAVIR scoring system at cut-off value of 2.49 with sensitivity 100%, specificity 66%, and area under the receiver-operating characteristics (AUROC) 0.8. FibroScan was able to predict significant fibrosis at cut-off value 7.5 KPa with sensitivity 88%, specificity 100%, and AUROC 0.94.APRI was able to predict significant hepatic fibrosis (F ≥2) with sensitivity 54%, specificity 80%, and AUROC 0.69. There was a significant positive correlation between the FibroScan score and RTE score (r=0.6, P=0.001). Although FibroScan is superior in determining significant hepatic fibrosis, our data suggest that RTE may be a useful and promising noninvasive method for liver fibrosis assessment in CHC patients especially in cases with technical limitations for FibroScan.

  10. Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis.

    PubMed

    Alrajab, Saadah; Youssef, Asser M; Akkus, Nuri I; Caldito, Gloria

    2013-09-23

    Ultrasonography is being increasingly utilized in acute care settings with expanding applications. Pneumothorax evaluation by ultrasonography is a fast, safe, easy and inexpensive alternative to chest radiographs. In this review, we provide a comprehensive analysis of the current literature comparing ultrasonography and chest radiography for the diagnosis of pneumothorax. We searched English-language articles in MEDLINE, EMBASE and Cochrane Library dealing with both ultrasonography and chest radiography for diagnosis of pneumothorax. In eligible studies that met strict inclusion criteria, we conducted a meta-analysis to evaluate the diagnostic accuracy of pleural ultrasonography in comparison with chest radiography for the diagnosis of pneumothorax. We reviewed 601 articles and selected 25 original research articles for detailed review. Only 13 articles met all of our inclusion criteria and were included in the final analysis. One study used lung sliding sign alone, 12 studies used lung sliding and comet tail signs, and 6 studies searched for lung point in addition to the other two signs. Ultrasonography had a pooled sensitivity of 78.6% (95% CI, 68.1 to 98.1) and a specificity of 98.4% (95% CI, 97.3 to 99.5). Chest radiography had a pooled sensitivity of 39.8% (95% CI, 29.4 to 50.3) and a specificity of 99.3% (95% CI, 98.4 to 100). Our meta-regression and subgroup analyses indicate that consecutive sampling of patients compared to convenience sampling provided higher sensitivity results for both ultrasonography and chest radiography. Consecutive versus nonconsecutive sampling and trauma versus nontrauma settings were significant sources of heterogeneity. In addition, subgroup analysis showed significant variations related to operator and type of probe used. Our study indicates that ultrasonography is more accurate than chest radiography for detection of pneumothorax. The results support the previous investigations in this field, add new valuable information

  11. Enterobius vermicularis infection of the liver in a patient with colorectal carcinoma with suspected liver metastasis

    PubMed Central

    Furnée, Edgar J B; Spoto, Clothaire; de Graaf, Melanie J; Smakman, Niels

    2015-01-01

    A 68-year-old man diagnosed with cT3N2 adenocarcinoma of the rectum presented with a synchronous solitary liver metastasis on CT scan. Neoadjuvant chemoradiotherapy was started to downstage the primary tumour. Resection of the rectal tumour followed 3 months after the last radiotherapy session and primary resection of the isolated liver lesion was performed in the intervening period. Histopathological assessment of the liver lesion, however, showed no malignancy, but did reveal a necrotic infection due to Enterobius vermicularis. This parasite is frequently found in the intestines, but only rarely infects the liver. The patient was subsequently treated with the anthelmintic drug mebendazole 100 mg once a week for 2 weeks. Histopathological assessment of the rectal specimen showed complete regression after neoadjuvant chemoradiotherapy without evidence of remaining E. vermicularis, suggesting pinworm eradication. The patient recovered promptly after both surgical procedures. PMID:26546623

  12. Poster — Thur Eve — 16: 4DCT simulation with synchronized contrast injection of liver SBRT patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karotki, A.; Korol, R.; Milot, L.

    2014-08-15

    Stereotactic body radiation therapy (SBRT) has recently emerged as a valid option for treating liver metastases. SBRT delivers highly conformai dose over a small number of fractions. As such it is particularly sensitive to the accuracy of target volume delineation by the radiation oncologist. However, contouring liver metastases remains challenging for the following reasons. First, the liver usually undergoes significant motion due to respiration. Second, liver metastases are often nearly indistinguishable from the surrounding tissue when using computed tomography (CT) for imaging making it difficult to identify and delineate them. Both problems can be overcome by using four dimensional CTmore » (4DCT) synchronized with intravenous contrast injection. We describe a novel CT simulation process which involves two 4DCT scans. The first scan captures the tumor and immediately surrounding tissue which in turn reduces the 4DCT scan time so that it can be optimally timed with intravenous contrast injection. The second 4DCT scan covers a larger volume and is used as the primary CT dataset for dose calculation, as well as patient setup verification on the treatment unit. The combination of two 4DCT scans, short and long, allows visualization of the liver metastases over all phases of breathing cycle while simultaneously acquiring long enough 4DCT dataset suitable for planning and patient setup verification.« less

  13. Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta

    PubMed Central

    Riteau, Anne-Sophie; Tassin, Mikael; Chambon, Guillemette; Le Vaillant, Claudine; de Laveaucoupet, Jocelyne; Quéré, Marie-Pierre; Joubert, Madeleine; Prevot, Sophie; Philippe, Henri-Jean; Benachi, Alexandra

    2014-01-01

    Purpose To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. Material and Methods This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. Results Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. Conclusion Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs. PMID:24733409

  14. Reversible Causes in Cardiovascular Collapse at the Emergency Department Using Ultrasonography (REVIVE-US).

    PubMed

    Chua, Mui Teng; Chan, Gene Wh; Kuan, Win Sen

    2017-08-01

    Ultrasonographic evaluation of patients in cardiac arrest is currently not protocolised in the advanced cardiac life support (ACLS) algorithm. Potentially reversible causes may be identified using bedside ultrasonography that is ubiquitous in most emergency departments (EDs). This study aimed to evaluate the incidence of sonographically detectable reversible causes of cardiac arrest by incorporating an ultrasonography protocol into the ACLS algorithm. Secondary objectives include rates of survival to hospital admission, hospital discharge, and 30-day mortality. We conducted a prospective study using bedside ultrasonography to evaluate for potentially reversible causes in patients with cardiac arrest at the ED of National University Hospital, Singapore, regardless of the initial electrocardiogram rhythm. A standardised ultrasonography protocol was performed during the 10-second pulse check window. Between June 2015 and April 2016, 104 patients were recruited, corresponding to 65% of all out-of-hospital cardiac arrest patients conveyed to the ED. Median age was 71 years (interquartile range, 55 to 80) and 71 (68.3%) patients were male. The most common rhythm on arrival was asystole (45.2%). Four (3.8%) patients had ultrasonographic findings suggestive of massive pulmonary embolism while 1 received intravenous thrombolysis and survived until discharge. Pericardial effusion without tamponade was detected in 4 (3.8%) patients and 6 (5.8%) patients had intra-abdominal free fluid. Twenty (19.2%) patients survived until admission, 2 of whom (1.9%) survived to discharge and beyond 30 days. Bedside ultrasonography can be safely incorporated into the ACLS protocol. Detection of any reversible causes may alter management and improve survival in selected patients.

  15. Unusual Discovery after an Examination for Abdominal Pain: Abernethy 1b Malformation and Liver Adenomatosis. A Case Report.

    PubMed

    Chira, Romeo Ioan; Calauz, Adriana; Manole, Simona; Valean, Simona; Mircea, Petru Adrian

    2017-03-01

    Congenital extrahepatic portosystemic shunt (Abernethy malformation) is a rare condition characterized by developmental abnormalities of the portal venous system resulting in the diversion of the portal blood from the liver to the systemic venous system through a complete or partial shunt of the portomesenteric blood. We report the case of an 18 year-old female examined for abdominal pain, presenting cholestasis syndrome and an elevated serum aspartate aminotransferase level. Liver ultrasound examination revealed the absence of the portal vein with a complete extrahepatic shunt of the portal blood, multiple focal liver lesions, and multiple associated vascular anomalies. A surgical portosystemic shunt and a secondary portosystemic shunt due to portal vein thrombosis were excluded, enabling the diagnosis of a congenital portosystemic shunt. A complex investigation also discovered bone anomalies, and the liver biopsy of the dominant focal lesion revealed adenoma. On a short-term follow-up under hepatoprotective medication, the biochemical parameters improved mildly; however, the size of the main focal lesion increased. Congenital absence of the portal vein often remains an incidental diagnosis. In experienced hands, ultrasonography can diagnose it, but a comprehensive thoraco-abdominal evaluation is compulsory, considering the many potential associated anomalies. In these patients, development of adenomatous liver lesions secondary to Abernethy type Ib malformation represents an indication for liver transplantation.

  16. The Oxford scanning proton microprobe: A medical diagnostic application

    NASA Astrophysics Data System (ADS)

    Watt, F.; Grime, G. W.; Takacs, J.; Vaux, D. J. T.

    1984-04-01

    Primary biliary cirrhosis (PBC) is a disease characterised by progressive destruction of small intrahepatic bile ducts, cholestasis, and high levels of copper within the liver. The Oxford 1 μm scanning proton microprobe (SPM) has been used to construct elemental maps of a 7 μm section of diseased liver at several different magnifications. The results of these investigations have shown that the copper is distributed in small deposits ( < 5 μm) at specific locations in the liver. Further there appears to be a 1:1 atomic correlation between copper and sulphur, indicating the presence of an inorganic salt or a protein with approximately equal numbers of copper and sulphur atoms.

  17. SU-F-T-121: Abdominal Compression Effectively Reduces the Interplay Effect and Enables Pencil Beam Scanning Proton Therapy of Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souris, K; University of Pennsylvania, Philadelphia, PA; Glick, A

    Purpose: To study if abdominal compression can reduce breathing motion and mitigate interplay effect in pencil beam scanning proton therapy (PBSPT) treatment of liver tumors in order to better spare healthy liver volumes compared with photon therapy. Methods: Ten patients, six having large tumors initially treated with IMRT and four having small tumors treated with SBRT, were replanned for PBSPT. ITV and beam-specific PTVs based on 4D-CT were used to ensure target coverage in PBSPT. The use of an abdominal compression belt and volumetric repainting was investigated to mitigate the interplay effect between breathing motion and PBSPT dynamic delivery. Anmore » in-house Matlab script has been developed to simulate this interplay effect. The dose is computed on each phase individually by sorting all spots according to their simulated delivery timing. The final dose distribution is then obtained by accumulating all dose maps to a reference phase. Results: For equivalent target coverage PBSPT reduced average healthy liver dose by 9.5% of the prescription dose compared with IMRT/SBRT. Abdominal compression of 113.2±42.2 mmHg was effective for all 10 patients and reduced average motion by 2.25 mm. As a result, the average ITV volume decreased from 128.2% to 123.1% of CTV volume. Similarly, the average beam-specific PTV volume decreased from 193.2% to 183.3%. For 8 of the 10 patients, the average motion was reduced below 5 mm, and up to 3 repainting were sufficient to mitigate interplay. For the other two patients with larger residual motion, 4–5 repainting were needed. Conclusion: We recommend evaluation of the 4DCT motion histogram following simulation and the interplay effect following treatment planning in order to personalize the use of compression and volumetric repainting for each patient. Abdominal compression enables safe and more effective PBS treatment of liver tumors by reduction of motion and interplay effect. Kevin Souris is supported by IBA and Televie

  18. A novel two-dimensional dynamic anal ultrasonography technique to assess anismus comparing with three-dimensional echodefecography.

    PubMed

    Murad-Regadas, S M; Regadas, F S P; Barreto, R G L; Rodrigues, L V; de Souza, M H L P

    2009-10-01

    The aim of this prospective study was to test two-dimensional dynamic anorectal ultrasonography (2D-DAUS) in the assessment of anismus and compare it with echodefecography (ECD). Fifty consecutive female patients with outlet delay were submitted to 2D and 3D-DAUS, measuring the relaxing or contracting puborectalis muscle angle during straining. The patients were assigned to one of two groups based on ECD findings. Group I consisted of 29 patients without anismus and group II included 21 patients diagnosed with anismus. Subsequently 2D-DAUS images were checked for anismus and compared with ECD findings. Upon straining, the angle produced by the movement of the puborectalis muscle decreased in 26 out of the 29 (89.6%) patients of group I and increased 19 out of the 21 (90.4%) patients of group II. The mean angle during straining differed significantly between group I and group II. The index of agreement between the two scanning modes was 89.6% (26/29) for group I (Kappa: 0.796; CI: 95%; range: 0.51-1.0) and 90.4% (19/21) for group II (Kappa: 0.796; CI: 95%; range: 0.51-1.0). Two-dimensional dynamic anal ultrasonography can be used as an alternative method to assess patients with anismus, although the 3-D modality is more precise to evaluate the PR angle as the sphincters integrity as the whole muscle length is clearly visualized.

  19. CT texture features of liver parenchyma for predicting development of metastatic disease and overall survival in patients with colorectal cancer.

    PubMed

    Lee, Scott J; Zea, Ryan; Kim, David H; Lubner, Meghan G; Deming, Dustin A; Pickhardt, Perry J

    2018-04-01

    To determine if identifiable hepatic textural features are present at abdominal CT in patients with colorectal cancer (CRC) prior to the development of CT-detectable hepatic metastases. Four filtration-histogram texture features (standard deviation, skewness, entropy and kurtosis) were extracted from the liver parenchyma on portal venous phase CT images at staging and post-treatment surveillance. Surveillance scans corresponded to the last scan prior to the development of CT-detectable CRC liver metastases in 29 patients (median time interval, 6 months), and these were compared with interval-matched surveillance scans in 60 CRC patients who did not develop liver metastases. Predictive models of liver metastasis-free survival and overall survival were built using regularised Cox proportional hazards regression. Texture features did not significantly differ between cases and controls. For Cox models using all features as predictors, all coefficients were shrunk to zero, suggesting no association between any CT texture features and outcomes. Prognostic indices derived from entropy features at surveillance CT incorrectly classified patients into risk groups for future liver metastases (p < 0.001). On surveillance CT scans immediately prior to the development of CRC liver metastases, we found no evidence suggesting that changes in identifiable hepatic texture features were predictive of their development. • No correlation between liver texture features and metastasis-free survival was observed. • Liver texture features incorrectly classified patients into risk groups for liver metastases. • Standardised texture analysis workflows need to be developed to improve research reproducibility.

  20. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study

    PubMed Central

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Introduction: Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. Methods: This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. Results: 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. Conclusion The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures. PMID:28286822

  1. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    PubMed

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  2. Comparative evaluation of the liver in dogs with a splenic mass by using ultrasonography and contrast-enhanced computed tomography

    PubMed Central

    Irausquin, Roelof A.; Scavelli, Thomas D.; Corti, Lisa; Stefanacci, Joseph D.; DeMarco, Joann; Flood, Shannon; Rohrbach, Barton W.

    2008-01-01

    Evaluation of dogs with splenic masses to better educate owners as to the extent of the disease is a goal of many research studies. We compared the use of ultrasonography (US) and contrast-enhanced computed tomography (CT) to evaluate the accuracy of detecting hepatic neoplasia in dogs with splenic masses, independently, in series, or in parallel. No significant difference was found between US and CT. If the presence or absence of ascites, as detected with US, was used as a pretest probability of disease in our population, the positive predictive value increased to 94% if the tests were run in series, and the negative predictive value increased to 95% if the tests were run in parallel. The study showed that CT combined with US could be a valuable tool in evaluation of dogs with splenic masses. PMID:18320977

  3. Ultrasonography in determining pubertal growth and bone age.

    PubMed

    Torenek Ağırman, Kubra; Bilge, Osman Murat; Miloğlu, Özkan

    2018-05-02

    The purpose of this study is to evaluate the compatibility of ultrasonographic data with hand-wrist radiographs taken to determine the extent of pubertal growth and bone age in patients and investigate the usability of ionizing radiation-free ultrasonography instead of conventional radiography. In this study, a total of 120 children from 10 to 17 years old (mean age was 168 months ± 27.5 months) were treated with routine radiographs before orthodontic treatment, and ultrasonographic imaging was performed on the wrists the same day. Researchers examined the phalanges, sesamoid bone, and radial bone distal epiphysis-diaphysis comparatively in each patient by both imaging methods and statistical evaluation. There was no statistically significant difference between conventional radiography and ultrasonography values at 13 points except for PP1 (proximal phalanges of the first finger), PP2 (proximal phalanges of the second finger), and radial epiphysis (p > 0.05). PP1, PP2, and radial epiphysis showed a statistically significant difference (p < 0.05). The CBA (bone age obtained from conventional radiographs) of the females was found to be larger than their CA (chronological age) and their UBA (ultrasonographic bone age). For males; the means of the CBA, UBA and CA values close to each other. In females and males; there was a strong correlation between the CA, the UBA and the CBA (p < 0.01). Ultrasonography gives detailed information about epiphyseal diaphysis relations. It can be used as an alternative to conventional radiography in the detection of bone age and pubertal growth, owing to the absence of ionizing radiation.

  4. Assessment of Oropharyngeal Dysphagia in Patients With Parkinson Disease: Use of Ultrasonography.

    PubMed

    Oh, Eun Hyun; Seo, Jin Seok; Kang, Hyo Jung

    2016-04-01

    To compare tongue thickness, the shortest hyoid-thyroid approximation (distance between the hyoid bone and thyroid cartilage), and the time interval between the initiation of tongue movement and the time of the shortest hyoid-thyroid approximation, by using ultrasonography in healthy controls and patients with Parkinson disease (PD). Healthy controls and PD patients with dysphagia were compared. Ultrasonography was performed 3 times for the evaluation of tongue thickness, the shortest hyoid-thyroid approximation, and the time between the initiation of tongue movement and the shortest hyoid-thyroid approximation. A total of 24 healthy controls and 24 PD patients with dysphagia were enrolled. No significant differences were demonstrated between the two groups for the shortest hyoid-thyroid approximation (controls, 1.19±0.34 cm; PD patients, 1.37±0.5 cm; p=0.15) and tongue thickness (controls, 4.42±0.46 cm; PD patients, 4.27±0.51 cm; p=0.3). In contrast, the time to the shortest hyoid-thyroid approximation was significantly different between the two groups (controls, 1.53±0.87 ms; PD patients, 2.4±1.4 ms, p=0.048). Ultrasonography can be useful in evaluating dysphagia in patients with PD by direct visualization and measurement of the hyoid bone. Moreover, ultrasonography might contribute to a greater understanding of the pathophysiology of dysphagia in PD.

  5. Nonalcoholic fatty liver in patients with Laron syndrome and GH gene deletion - preliminary report.

    PubMed

    Laron, Zvi; Ginsberg, Shira; Webb, Muriel

    2008-10-01

    There is little information on the relationship between growth hormone/insulin-like growth factor-I (GH/IGF-I) deficiency or IGF-I treatment on nonalcoholic fatty liver disease (NAFLD) a disorder linked to obesity and insulin resistance. To find out whether the markedly obese patients with Laron syndrome (LS) and GH gene deletion have fatty livers. We studied 11 untreated adult patients with LS (5M, 6F), five girls with LS treated by IGF-I and five adult patients with GH gene deletion (3M, 3F), four previously treated by hGH in childhood. Fatty liver was quantitatively evaluated by ultrasonography using a phase array US system (HITACHI 6500, Japan). Body adiposity was determined by DEXA, and insulin resistance was estimated by HOMA-IR using the fasting serum glucose and insulin values. Six out of 11 adult patients with LS, two out of the five IGF-I treated girls with LS and three out of five adult hGH gene deletion patients were found to have NAFLD (nonalcoholic fatty liver disease). NAFLD is a frequent complication in untreated and treated congenital IGF-I deficiency. No correlation between NAFLD and age, sex, degree of obesity, blood lipids, or degree of insulin resistance was observed.

  6. Monomicrobial Klebsiella pneumoniae Necrotizing Fasciitis With Liver Abscess: A Case Report and Literature Review.

    PubMed

    Chen, Ching-En; Shih, Yu-Chung

    2017-03-01

    Necrotizing fasciitis is one of the most life-threatening soft tissue infections and usually follows a major or minor trauma. Published reports regarding single microorganism liver abscess caused by Klebsiella pneumoniae in Taiwan indicate a septic metastasis rate about 12%. Although a hematogenous origin of necrotizing fasciitis from a liver abscess is rare in Taiwan, it remains possible in our clinical practice. A 75-year-old man with a history of diabetes and liver abscess had a status of postdrainage 5 years earlier. The patient presented with elevated body temperature, swelling, and pain over the left hand and forearm for 4 days before coming to our emergency room. We performed a fasciotomy procedure under the preliminary diagnosis of necrotizing fasciitis. The patient's blood cultures yielded K. pneumoniae, and therefore recurrence of liver abscess was confirmed by ultrasonography. After treating with percutaneous drainage and third cephalosporin intravenously, the patient recovered and discharged on the 50th day after admission. Necrotizing fasciitis is a life-threatening soft tissue infectious disease. Once K. pneumoniae is identified both in blood and wound cultures of a diabetic patient with necrotizing fasciitis, it is recommended that the metastatic lesions undergo complete abdominal evaluation by the hematogenous route.

  7. Transabdominal ultrasonography as a screening test for second-trimester placenta previa.

    PubMed

    Quant, Hayley S; Friedman, Alexander M; Wang, Eileen; Parry, Samuel; Schwartz, Nadav

    2014-03-01

    To determine the test characteristics of transabdominal ultrasonography as a screening test for second-trimester placenta previa. This secondary analysis of a prospective cohort study evaluated the distance from the placental edge to the internal os (placenta-cervix distance) through both transabdominal and transvaginal ultrasonography during the anatomic survey. Patients were recruited in the Maternal-Fetal Medicine Ultrasound Unit at the Hospital of the University of Pennsylvania, an urban tertiary care center. Transabdominal placenta-cervix distance cutoffs with high sensitivity for detection of previa and low-lying placenta were identified, and test characteristics were calculated. Follow-up ultrasound data, pregnancy, and delivery outcomes for those with second-trimester previa or low-lying placenta were obtained. One thousand two hundred fourteen women were included in the analysis. A transabdominal placenta-cervix distance cutoff of 4.2 cm was 93.3% sensitive and 76.7% specific for detection of previa with a 99.8% negative predictive value at a screen-positive rate of 25.0%. A cutoff of 2.8 cm was 86.7% sensitive and 90.5% specific with a 99.6% negative predictive value at a screen-positive rate of 11.4%. Only 9.8% (four of 41) of previas and low-lying placentas persisted through delivery. Transabdominal ultrasonography is an effective screening test for second-trimester placenta previa. At centers not performing universal transvaginal ultrasonography at the time of the anatomic survey, evidence-based transabdominal placenta-cervix distance cutoffs can optimize the identification of patients who require further surveillance for previa.

  8. The benefits and limitations of using ultrasonography to supplement anatomical understanding.

    PubMed

    Sweetman, Greg M; Crawford, Gail; Hird, Kathryn; Fear, Mark W

    2013-01-01

    Anatomical understanding is critical to medical education. With reduced teaching time and limited cadaver availability, it is important to investigate how best to utilize in vivo imaging to supplement anatomical understanding and better prepare medical graduates for the proliferation of point-of-care imaging in the future. To investigate whether using short sessions of in vivo imaging using ultrasonography could benefit students' anatomical knowledge and clinical application, we conducted a 2-hour session on abdominal anatomy using ultrasonography in small groups of five to six students, for both first- and second-year student cohorts. Individual feedback was collected to assess student perceptions. To measure retention and understanding, a short examination containing ultrasound images and questions and performance of a clinical skill (gastrointestinal' tract examination) were assessed. Ultrasonography sessions were highly valued by the students, with 90% of the students reporting their understanding was improved, and over 70% reporting increased confidence in their anatomical knowledge. However, the assessments showed no appreciable impact on skills or understanding related to abdominal anatomy and examination. We conclude that the risk associated with limited exposure increasing confidence without increasing skills remains real and that in vivo imaging is not effective when used as a short adjunct teaching tool. The widespread use of ultrasonography means finding the best way to incorporate ultrasound into medical education remains important. To this end, we are currently implementing an extended program including echocardiography and multiple anatomical sessions that will determine if frequency and repetition of use can positively impact on student performance and understanding. Copyright © 2012 American Association of Anatomists.

  9. Does apparent diffusion coefficient predict the degree of liver regeneration of donor and recipient after living donor liver transplantation?

    PubMed

    Morita, Koichiro; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Ikegami, Toru; Yoshizumi, Tomoharu; Shirabe, Ken; Honda, Hiroshi

    2017-05-01

    To elucidate the relationship between the ADCs of the liver graft and the remnant liver and the degree of liver regeneration in LDLT. 15 recipients and 15 corresponding donors underwent magnetic resonance imaging and computed tomography 1-2 weeks after living donor liver transplantation (LDLT). For diffusion-weighted imaging (DWI), a single-shot echo-planar sequence with b-factors of 0, 500, and 1000s/mm 2 was scanned. ADCs of the liver parenchyma were calculated at b factors of 0 and 500 and 1000 (ADC 0-500-1000) or 0 and 500 (ADC 0-500) or 500 and 1000 (ADC 500-1000). The liver volume ratio at LDLT, the mean ADCs and the regeneration rate were compared between the graft and the remnant liver using paired-t tests. The mean liver volume ratio of the recipients (41.3±9.8%) tended to be smaller than that of the donors (51.8±13.8%). The mean ADC 0-500 of the remnant liver (1.72±0.33) was significantly higher than that of the graft (1.43±0.32). The regeneration rate of the graft (2.07±0.41) was significantly higher than that of the remnant liver (1.53±0.49). ADC 0-500 can describe differences in blood perfusion between liver grafts and the remnant liver according to the degree of liver regeneration. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Tissue lesion created by HIFU in continuous scanning mode

    NASA Astrophysics Data System (ADS)

    Fan, Tingbo; Liu, Zhenbo; Zhang, Dong

    2012-09-01

    The lesion formation was numerically and experimentally investigated by the continuous scanning mode. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetov (KZK) equation and bio-heat equation. Measurements were performed on porcine liver tissues using a 1.01 MHz single-element focused transducer at various acoustic powers, confirmed the predicted results. Controlling of the peak temperature and lesion by the scanning speed may be exploited for improvement of efficiency in HIFU therapy.

  11. Ultrasonography of the male breast.

    PubMed

    Draghi, F; Tarantino, C C; Madonia, L; Ferrozzi, G

    2011-09-01

    The male breast has been insufficiently explored in the medical literature, particularly that dealing with ultrasonography, although this topic is almost as vast and varied as that of the female breast. The purpose of this article is to provide a schematic review of the most frequent breast lesions encountered in males and their sonographic appearances. After a brief introduction on the anatomy of the male breast, the authors review the non-neoplastic (gynecomastia, pseudogynecomastia, cysts, inflammatory diseases, and Mondor disease) and neoplastic (benign and malignant) lesions encountered in this organ.

  12. Ultrasonography of the male breast

    PubMed Central

    Draghi, F.; Tarantino, C.C.; Madonia, L.; Ferrozzi, G.

    2011-01-01

    The male breast has been insufficiently explored in the medical literature, particularly that dealing with ultrasonography, although this topic is almost as vast and varied as that of the female breast. The purpose of this article is to provide a schematic review of the most frequent breast lesions encountered in males and their sonographic appearances. After a brief introduction on the anatomy of the male breast, the authors review the non-neoplastic (gynecomastia, pseudogynecomastia, cysts, inflammatory diseases, and Mondor disease) and neoplastic (benign and malignant) lesions encountered in this organ. PMID:23397020

  13. Real-time elastography as a noninvasive assessment of liver fibrosis in chronic hepatitis C Egyptian patients: a prospective study

    PubMed Central

    Mobarak, Lamiaa; Nabeel, Mohammed M.; Hassan, Ehsan; Omran, Dalia; Zakaria, Zeinab

    2016-01-01

    Background Hepatitis C virus is a worldwide problem. Noninvasive methods for liver fibrosis assessment as ultrasound-based approaches have emerged to replace liver biopsy. The aim of this study was to evaluate the diagnostic accuracy of real-time elastography (RTE) in the assessment of liver fibrosis in patients with chronic hepatitis C (CHC), compared with transient elastography and liver biopsy. Methods RTE, FibroScan and liver biopsy were performed in 50 CHC patients. In addition, aspartate aminotransferase to platelet ratio index (APRI) and routine laboratory values were included in the analysis. Results RTE was able to diagnose significant hepatic fibrosis (F ≥2) according to METAVIR scoring system at cut-off value of 2.49 with sensitivity 100%, specificity 66%, and area under the receiver-operating characteristics (AUROC) 0.8. FibroScan was able to predict significant fibrosis at cut-off value 7.5 KPa with sensitivity 88%, specificity 100%, and AUROC 0.94.APRI was able to predict significant hepatic fibrosis (F ≥2) with sensitivity 54%, specificity 80%, and AUROC 0.69. There was a significant positive correlation between the FibroScan score and RTE score (r=0.6, P=0.001). Conclusions Although FibroScan is superior in determining significant hepatic fibrosis, our data suggest that RTE may be a useful and promising noninvasive method for liver fibrosis assessment in CHC patients especially in cases with technical limitations for FibroScan. PMID:27366038

  14. Use of ultrasonography to make reproductive management decisions

    USDA-ARS?s Scientific Manuscript database

    Transrectal ultrasonography has been available for making management decisions since the mid 1980’s. This technology allows for the real-time visualization of internal structures (i.e. ovary and fetus) that are otherwise difficult to evaluate. The use of this technology in making reproductive manag...

  15. Vascular access: the impact of ultrasonography

    PubMed Central

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  16. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype.

    PubMed

    Al Kaissi, Ali; Chehida, Farid Ben; Ganger, Rudolf; Grill, Franz

    2014-01-01

    We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT) scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (consanguineous marriage) strongly suggests autosomal recessive pattern of inheritance. To our knowledge, this is the first report of neonatal death dwarfism of Grebe syndrome analyzed by CT scan-based phenotype.

  17. Acceleration of hepatobiliary dynamics in liver transplant donors.

    PubMed

    Aktaş, A; Koyuncu, A; Yalçin, H

    2004-01-01

    This study compared hepatobiliary scintigraphy findings in livers before and after liver graft donation to examine whether there is a change in hepatobiliary dynamics. Nine donors underwent hepatobiliary scintigraphy with intravenous injection of Tc-99m mebrofenin 1 day before and during the first week after left liver lobectomy. Five donors also underwent additional scintigraphy more than 1 year postsurgery. Images were acquired every second for the first minute, and then every minute for the next 40 minutes. Hepatic arterial perfusion index and portal perfusion index(PPI) were calculated from the images acquired during the first minute. For the function phase the computed parameters included: hepatic extraction efficiency, (HEE), time to appearance of activity in the intrahepatic biliary channels, and in the intestine, time to half maximal activity, and activity retained in the liver parenchyma at 40 minutes. Time to appearance of intrahepatic biliary channels and of intestinal activity was shorter among scintigraphies obtained within 1 week postsurgery compared to the preoperative values. Early after the operation HEE increased and PPI decreased significantly. Visual inspection of the scintigraphy scan obtained in all donors, within the first week postsurgery revealed hypertrophy of the right liver lobe. None of the patients showed progression of right lobe activity to the left side, even among scans obtained more than 1 year after donation. Reduced time to activity in the biliary channels and intestine and increased HEE suggest acceleration of hepatobiliary dynamics.

  18. A fatal case of hemoperitoneum after ultrasound-guided liver biopsy in a patient with intravascular large B-cell lymphoma.

    PubMed

    Aoki, Yasuhiro; Takamiya, Masataka; Satoh, Takashi; Fujita, Sachiko; Kato, Hideaki; Maeno, Yoshitaka

    2011-07-01

    An autopsy case of fatal complication of percutaneous liver biopsy targeting a rare type of large B-cell lymphoma is presented. A 79 year-old man was referred to the hematology unit of a hospital because of anemia with thrombocytopenia and hepatosplenomegaly. Results of inguinal lymph node biopsy were inconclusive. To investigate a mass lesion in the liver visualized by ultrasonography, image-guided liver biopsy was performed following platelet infusion. The patient became unresponsive 6h post procedure because of hypotension due to intraperitoneal hemorrhage of undetermined origin. Autopsy revealed hemoperitoneum but failed to identify any macroscopic intra- or extrahepatic vascular injuries. Histopathological investigation disclosed infiltration of atypical lymphocytes into the systemic organs including the lymph nodes, spleen, liver, and lungs. Prominent hemophagocytosis was also noted. The lymphoma cells were exclusively accumulated within vascular and sinusoidal structures, and diagnosed with immunohistochemistry as Asian variant of intravascular large B-cell lymphoma. Massive blood extravasation was presumed to originate directly from the markedly dilated liver sinusoids filled with erythrocytes, macrophages and tumor cells, under the condition of impaired hemostasis. Although the biopsy was thought to have been correctly performed, this case would be instructive for evaluation of the indications and risks associated with liver biopsy. 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Defining the optimal cut-off values for liver enzymes in diagnosing blunt liver injury.

    PubMed

    Koyama, Tomohide; Hamada, Hirohisa; Nishida, Masamichi; Naess, Paal A; Gaarder, Christine; Sakamoto, Tetsuya

    2016-01-25

    Patients with blunt trauma to the liver have elevated levels of liver enzymes within a short time post injury, potentially useful in screening patients for computed tomography (CT). This study was performed to define the optimal cut-off values for serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in patients with blunt liver injury diagnosed with contrast enhanced multi detector-row CT (CE-MDCT). All patients admitted from May 2006 to July 2013 to Teikyo University Hospital Trauma and Critical Care Center, and who underwent abdominal CE-MDCT within 3 h after blunt trauma, were retrospectively enrolled. Using receiver operating characteristic (ROC) curve analysis, the optimal cut-off values for AST and ALT were defined, and sensitivity and specificity were calculated. Of a total of 676 blunt trauma patients 64 patients were diagnosed with liver injury (Group LI+) and 612 patients without liver injury (Group LI-). Group LI+ and LI- were comparable for age, Revised Trauma Score, and Probability of survival. The groups differed in Injury Severity Score [median 21 (interquartile range 9-33) vs. 17 (9-26) (p < 0.01)]. Group LI+ had higher AST than LI- [276 (48-503) vs. 44 (16-73); p < 0.001] and higher ALT [240 (92-388) vs. 32 (16-49); p < 0.001]. Using ROC curve analysis, the optimal cut-off values for AST and ALT were set at 109 U/l and 97 U/l, respectively. Based on these values, AST ≥ 109 U/l had a sensitivity of 81%, a specificity of 82%, a positive predictive value of 32%, and a negative predictive value of 98%. The corresponding values for ALT ≥ 97 U/l were 78, 88, 41 and 98%, respectively, and for the combination of AST ≥ 109 U/l and/or ALT ≥ 97 U/l were 84, 81, 32, 98%, respectively. We have identified AST ≥ 109 U/l and ALT ≥ 97 U/l as optimal cut-off values in predicting the presence of liver injury, potentially useful as a screening tool for CT scan in patients otherwise eligible for observation only or as a transfer

  20. SU-E-J-240: Development of a Novel 4D MRI Sequence for Real-Time Liver Tumor Tracking During Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhuang, L; Burmeister, J; Ye, Y

    2015-06-15

    Purpose: To develop a Novel 4D MRI Technique that is feasible for realtime liver tumor tracking during radiotherapy. Methods: A volunteer underwent an abdominal 2D fast EPI coronal scan on a 3.0T MRI scanner (Siemens Inc., Germany). An optimal set of parameters was determined based on image quality and scan time. A total of 23 slices were scanned to cover the whole liver in the test scan. For each scan position, the 2D images were retrospectively sorted into multiple phases based on breathing signal extracted from the images. Consequently the 2D slices with same phase numbers were stacked to formmore » one 3D image. Multiple phases of 3D images formed the 4D MRI sequence representing one breathing cycle. Results: The optimal set of scan parameters were: TR= 57ms, TE= 19ms, FOV read= 320mm and flip angle= 30°, which resulted in a total scan time of 14s for 200 frames (FMs) per slice and image resolution of (2.5mm,2.5mm,5.0mm) in three directions. Ten phases of 3D images were generated, each of which had 23 slices. Based on our test scan, only 100FMs were necessary for the phase sorting process which may lower the scan time to 7s/100FMs/slice. For example, only 5 slices/35s are necessary for a 4D MRI scan to cover liver tumor size ≤ 2cm leading to the possibility of tumor trajectory tracking every 35s during treatment. Conclusion: The novel 4D MRI technique we developed can reconstruct a 4D liver MRI sequence representing one breathing cycle (7s/ slice) without an external monitor. This technique can potentially be used for real-time liver tumor tracking during radiotherapy.« less

  1. Quantitative PET of liver functions

    PubMed Central

    Keiding, Susanne; Sørensen, Michael; Frisch, Kim; Gormsen, Lars C; Munk, Ole Lajord

    2018-01-01

    Improved understanding of liver physiology and pathophysiology is urgently needed to assist the choice of new and upcoming therapeutic modalities for patients with liver diseases. In this review, we focus on functional PET of the liver: 1) Dynamic PET with 2-deoxy-2-[18F]fluoro-D-galactose (18F-FDGal) provides quantitative images of the hepatic metabolic clearance K met (mL blood/min/mL liver tissue) of regional and whole-liver hepatic metabolic function. Standard-uptake-value (SUV) from a static liver 18F-FDGal PET/CT scan can replace K met and is currently used clinically. 2) Dynamic liver PET/CT in humans with 11C-palmitate and with the conjugated bile acid tracer [N-methyl-11C]cholylsarcosine (11C-CSar) can distinguish between individual intrahepatic transport steps in hepatic lipid metabolism and in hepatic transport of bile acid from blood to bile, respectively, showing diagnostic potential for individual patients. 3) Standard compartment analysis of dynamic PET data can lead to physiological inconsistencies, such as a unidirectional hepatic clearance of tracer from blood (K 1; mL blood/min/mL liver tissue) greater than the hepatic blood perfusion. We developed a new microvascular compartment model with more physiology, by including tracer uptake into the hepatocytes from the blood flowing through the sinusoids, backflux from hepatocytes into the sinusoidal blood, and re-uptake along the sinusoidal path. Dynamic PET data include information on liver physiology which cannot be extracted using a standard compartment model. In conclusion, SUV of non-invasive static PET with 18F-FDGal provides a clinically useful measurement of regional and whole-liver hepatic metabolic function. Secondly, assessment of individual intrahepatic transport steps is a notable feature of dynamic liver PET. PMID:29755841

  2. Quantitative PET of liver functions.

    PubMed

    Keiding, Susanne; Sørensen, Michael; Frisch, Kim; Gormsen, Lars C; Munk, Ole Lajord

    2018-01-01

    Improved understanding of liver physiology and pathophysiology is urgently needed to assist the choice of new and upcoming therapeutic modalities for patients with liver diseases. In this review, we focus on functional PET of the liver: 1) Dynamic PET with 2-deoxy-2-[ 18 F]fluoro- D -galactose ( 18 F-FDGal) provides quantitative images of the hepatic metabolic clearance K met (mL blood/min/mL liver tissue) of regional and whole-liver hepatic metabolic function. Standard-uptake-value ( SUV ) from a static liver 18 F-FDGal PET/CT scan can replace K met and is currently used clinically. 2) Dynamic liver PET/CT in humans with 11 C-palmitate and with the conjugated bile acid tracer [ N -methyl- 11 C]cholylsarcosine ( 11 C-CSar) can distinguish between individual intrahepatic transport steps in hepatic lipid metabolism and in hepatic transport of bile acid from blood to bile, respectively, showing diagnostic potential for individual patients. 3) Standard compartment analysis of dynamic PET data can lead to physiological inconsistencies, such as a unidirectional hepatic clearance of tracer from blood ( K 1 ; mL blood/min/mL liver tissue) greater than the hepatic blood perfusion. We developed a new microvascular compartment model with more physiology, by including tracer uptake into the hepatocytes from the blood flowing through the sinusoids, backflux from hepatocytes into the sinusoidal blood, and re-uptake along the sinusoidal path. Dynamic PET data include information on liver physiology which cannot be extracted using a standard compartment model. In conclusion , SUV of non-invasive static PET with 18 F-FDGal provides a clinically useful measurement of regional and whole-liver hepatic metabolic function. Secondly, assessment of individual intrahepatic transport steps is a notable feature of dynamic liver PET.

  3. Laparoscopic microwave thermosphere ablation of malignant liver tumors: an initial clinical evaluation.

    PubMed

    Berber, Eren

    2016-02-01

    Microwave ablation (MWA) has been recently recognized as a technology to overcome the limitations of radiofrequency ablation. The aim of the current study was to evaluate the safety and efficacy of a new 2.45-GHz thermosphere MWA system in the treatment of malignant liver tumors. This was a prospective IRB-approved study of 18 patients with malignant liver tumors treated with MWA within a 3-month time period. Tumor sizes and response to MWA were obtained from triphasic liver CT scans done before and after MWA. The ablation zones were assessed for complete tumor response and spherical geometry. There were a total of 18 patients with an average of three tumors measuring 1.4 cm (range 0.2-4). Ablations were performed laparoscopically in all, but three patients who underwent combined liver resection. A single ablation was created in 72% and overlapping ablations in 28% of lesions. Total ablation time per patient was 15.6 ± 1.9 min. There was no morbidity or mortality. At 2-week CT scans, there was 100% tumor destruction, with no residual lesions. Roundness indices A, B and transverse were 1.1, 0.9 and 0.9, respectively, confirming the spherical nature of ablation zones. To the best of our knowledge, this is the first report of a new thermosphere MWA technology in the laparoscopic treatment of malignant liver tumors. The results demonstrate the safety of the technology, with satisfactory spherical ablation zones seen on post-procedural CT scans.

  4. Endoanal ultrasonography in fecal incontinence: Current and future perspectives.

    PubMed

    Albuquerque, Andreia

    2015-06-10

    Fecal incontinence has a profound impact in a patient's life, impairing quality of life and carrying a substantial economic burden due to health costs. It is an underdiagnosed condition because many affected patients are reluctant to report it and also clinicians are usually not alert to it. Patient evaluation with a detailed clinical history and examination is very important to indicate the type of injury that is present. Endoanal ultrasonography is currently the gold standard for sphincter evaluation in fecal incontinence and is a simple, well-tolerated and non-expensive technique. Most studies revealed 100% sensitivity in identifying sphincter defect. It is better than endoanal magnetic resonance imaging for internal anal sphincter defects, equivalent for the diagnosis of external anal sphincter defects, but with a lower capacity for assessment of atrophy of this sphincter. The most common cause of fecal incontinence is anal sphincter injury related to obstetric trauma. Only a small percentage of women are diagnosed with sphincter tears immediately after vaginal delivery, but endoanal ultrasonography shows that one third of these women have occult sphincter defects. Furthermore, in patients submitted to primary repair of these tears, ultrasound revealed a high frequency of persistent sphincter defects after surgery. Three-dimensional endoanal ultrasonography is currently largely used and accepted for sphincter evaluation in fecal incontinence, improving diagnostic accuracy and our knowledge of physiologic and pathological sphincters alterations. Conversely, there is currently no evidence to support the use of elastography in fecal incontinence evaluation.

  5. Electrophysiological examination and high frequency ultrasonography for diagnosis of radial nerve torsion and compression

    PubMed Central

    Shi, Miao; Qi, Hengtao; Ding, Hongyu; Chen, Feng; Xin, Zhaoqin; Zhao, Qinghua; Guan, Shibing; Shi, Hao

    2018-01-01

    Abstract This study aims to evaluate the value of electrophysiological examination and high frequency ultrasonography in the differential diagnosis of radial nerve torsion and radial nerve compression. Patients with radial nerve torsion (n = 14) and radial nerve compression (n = 14) were enrolled. The results of neurophysiological and high frequency ultrasonography were compared. Electrophysiological examination and high-frequency ultrasonography had a high diagnostic rate for both diseases with consistent results. Of the 28 patients, 23 were positive for electrophysiological examination, showing decreased amplitude and decreased conduction velocity of radial nerve; however, electrophysiological examination cannot distinguish torsion from compression. A total of 27 cases showed positive in ultrasound examinations among all 28 cases. On ultrasound images, the nerve was thinned at torsion site whereas thickened at the distal ends of torsion. The diameter and cross-sectional area of torsion or compression determined the nerve damage, and ultrasound could locate the nerve injury site and measure the length of the nerve. Electrophysiological examination and high-frequency ultrasonography can diagnose radial neuropathy, with electrophysiological examination reflecting the neurological function, and high-frequency ultrasound differentiating nerve torsion from compression. PMID:29480857

  6. WE-E-BRB-01: Personalized Motion Management Strategies for Pencil Beam Scanning Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, X.

    Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed.more » Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of

  7. Risk of Colorectal Neoplasia According to Fatty Liver Severity and Presence of Gall Bladder Polyps.

    PubMed

    Lee, Taeyoung; Yun, Kyung Eun; Chang, Yoosoo; Ryu, Seungho; Park, Dong Il; Choi, Kyuyong; Jung, Yoon Suk

    2016-01-01

    Fatty liver is the hepatic manifestation of metabolic syndrome (MetS) and is a known risk factor for colorectal neoplasia (CRN). Gallbladder (GB) polyps share many common risk factors with CRN. However, studies evaluating CRN risk according to fatty liver severity and the presence of GB polyps are rare. To investigate CRN risk according to the fatty liver severity and the presence of GB polyps. A retrospective cross-sectional study was performed on 44,220 participants undergoing colonoscopy and abdominal ultrasonography (US) as part of a health-screening program. Of the participants, fatty liver was diagnosed as mild in 27.7 %, moderate in 5.1 %, and severe in 0.4 % and 13.4 % were diagnosed with GB polyps. Mean age of participants was 42.7 years. In adjusted models, risk of overall CRN and non-advanced CRN increased with worsening fatty liver severity (P for trend = 0.007 and 0.020, respectively). Adjusted odd ratios for overall CRN and non-advanced CRN comparing participants with mild, moderate, and severe fatty liver to participants without fatty liver were 1.13 and 1.12 for mild, 1.12 and 1.10 for moderate, and 1.56 and 1.65 for severe. The presence of GB polyps did not correlate with CRN risk after adjusting for confounders. CRN risk increased with worsening fatty liver severity. However the association between GB polyp and CRN was not significant in the presence of other variables. Considering that many people undergo noninvasive abdominal US as a health screen, our study will contribute to colonoscopy screening strategies in people undergoing abdominal US.

  8. Radiocolloid liver imaging in tuberculous hepatitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Essop, A.R.; Posen, J.A.; Savitch, I.

    1984-02-01

    Twenty of 22 patients with tuberculous hepatitis had abnormal Tc-99m tin colloid liver scans. However, in the majority of the patients the changes were mild and nonspecific. The most frequent scintigraphic picture was a decreased uptake of the radiocolloid by the liver, with shunting to the spleen and bone marrow. The decreased hepatic uptake was usually mildly heterogeneous, but it was sometimes homogeneous, and in five patients obvious defects were present. The liver was enlarged in six patients and the spleen in six patients. Increased extrahepatic uptake of the radiocolloid was the only abnormality in five patients. The severity ofmore » the scintigraphic changes did not correlate with the following histologic findings: number of granulomas, degree of associated fibrosis, degree of hepatocyte swelling, or extent of fatty change.« less

  9. An unanticipated diagnosis with bedside ultrasonography in patients with acute abdominal pain: rectus hematoma.

    PubMed

    Ünlüer, Erden Erol; Kaykısız, Eylem Kuday

    2017-01-01

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and confirmed as RSH by computed tomography. Review of patient history and use of ultrasonography are important to avoid misdiagnosisof RSH.

  10. Case report : tuberculosis liver abscess in male alcoholism patient

    NASA Astrophysics Data System (ADS)

    Siahaan, W. P.; Ginting, F.

    2018-03-01

    A liver abscess often occurs in low-middle income countries such as Indonesia. Two most common liver abscesses are amoebic and pyogenic liver abscess. Data that reported tuberculosis liver abscess (TLA) is extremely rare. A diagnostic criterion for tuberculosis liver abscess is rare and remains unclear. A 52-year-old man developed a TLA which was not associated with any pulmonary or gastrointestinal tract foci of tuberculosis. An ultrasonogram and abdominal scan showed an abscess in the right lobe. We performed paracentesis, and the pus from the lesion was positive tubercular bacilli on acid-fast bacilli staining. The patient was started on systemic antitubercular therapy to which he responded favorably. This report emphasizes the fact that, although a TLA is a very rare entity, it should be included in the differential diagnosis of liver abscess especially in Indonesia where the prevalence of tuberculosis is extremely high.

  11. Failure of pre-natal ultrasonography to prevent urinary infection associated with underlying urological abnormalities.

    PubMed

    Lakhoo, K; Thomas, D F; Fuenfer, M; D'Cruz, A J

    1996-06-01

    To analyse the reasons underlying the failure of routine pre-natal ultrasonography to prevent the subsequent development of urinary tract infection (UTI) in children with predisposing urological abnormalities. This retrospective study comprised 39 children (22 females and 17 males) who had at least one documented UTI, the presence of an anatomical anomaly of the urinary tract recognized as predisposing to UTI and had undergone ultrasonography of the urinary tract undertaken in fetal life as part of routine maternal ante-natal ultrasonography. Four categories of patients were defined: Group A, those with normal findings on pre-natal ultrasonography and no urological abnormality detected; Group B, those with a urological abnormality detected but where there was a subsequent failure of communication among clinicians; Group C, those with a urological abnormality but who received inappropriate or sub-optimal post-natal management and; Group D, those with a urological abnormality but who had a UTI despite appropriate post-natal management. In each case, the most severe documented episode of UTI was categorized as: Grade I, asymptomatic bacteriuria; Grade II, mild/moderate symptomatic UTI and; Grade III, severe symptomatic UTI necessitating hospital admission. Group A comprised 22 (56%), Group B three (9%), Group C two (5%) and Group D 12 children (31%). Of the 22 children in Group A, nine experienced a UTI of sufficient severity to necessitate hospital admission. Of the 12 children in Group D only one required hospital admission. The failure of pre-natal ultrasonography to identify the underlying predisposing urological abnormality was the most important factor contributing to subsequent UTI in post-natal life. Failure of communication and inappropriate post-natal management were numerically unimportant. In some children, UTI occurred despite pre-natal detection of their underlying anomaly and appropriate post-natal management. However, in this group the UTI was less

  12. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    PubMed

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  13. Comparison of the accuracy of radiography and ultrasonography for detection of articular lesions in horses.

    PubMed

    Hinz, Antje; Fischer, Andrew T

    2011-10-01

    To compare the accuracy of ultrasonographic and radiographic examination for evaluation of articular lesions in horses. Cross-sectional study. Horses (n = 137) with articular lesions. Radiographic and ultrasonographic examinations of the affected joint(s) were performed before diagnostic or therapeutic arthroscopic surgery. Findings were recorded and compared to lesions identified during arthroscopy. In 254 joints, 432 lesions were identified by arthroscopy. The overall accuracy was 82.9% for ultrasonography and 62.2% for radiography (P < .0001) with a sensitivity of 91.4% for ultrasonography and 66.7% for radiography (P < .0001). The difference in specificity was not statistically significant (P = .2628). The negative predictive value for ultrasonography was 31.5% and 13.2% for radiography (P = .0022), the difference for the positive predictive value was not statistically significant (P = .3898). The accuracy for ultrasonography and radiography for left versus right joints was equal and corresponded with the overall results. Ultrasonographic evaluation of articular lesions was more accurate than radiographic evaluation. © Copyright 2011 by The American College of Veterinary Surgeons.

  14. Evaluation of Acoustic Radiation Force Impulse (ARFI) for Fibrosis Staging in Chronic Liver Diseases.

    PubMed

    Gani, Rino Alvani; Hasan, Irsan; Sanityoso, Andri; Lesmana, Cosmas Rinaldi A; Kurniawan, Juferdy; Jasirwan, Chyntia Olivia Maurine; Kalista, Kemal Fariz; Lutfie, Lutfie

    2017-04-01

    acoustic radiation force impulse (ARFI) is a new proposed noninvasive method for liver fibrosis staging. Integrated with B-mode ultrasonography, ARFI can be used to assess liver tissue condition. However its diagnostic accuracy is still being continuously evaluated. Also, there is lack of data regarding the utilization of ARFI in our population. This study aimed to evaluate the diagnostic value of ARFI as an alternative noninvasive modality for fibrosis staging in chronic hepatitis B and hepatitis C patients in our population. we conducted cross-sectional comparison of ARFI imaging and transient elastography on patients who underwent liver biopsy at Cipto Mangunkusumo Hospital. Fibrosis staging using METAVIR scoring system presented as standard reference. A total of 43 patients underwent liver biopsy was evaluated by ARFI imaging and transient elastography. Cut-off values were determined using receiver-operating characteristic (ROC). both liver stiffness determined by ARFI and transient elastography (TE) were moderately correlated with METAVIR score with value of 0.581 and 0.613, respectively (both P<0.01). Diagnostic accuracy of ARFI predicted significant fibrosis (F≥2) with area under receiver operating characteristic curve (AUROC) of 0.773 (95% CI 0.616-0.930) and even better for cirrhosis (F4 fibrosis), expressed as AUROC of 0.856 (95% CI 0.736-0.975). Transient elastography was better for significant fibrosis with AUROC of 0.761 (95% CI 0.601-0.920) and was best for prediction of cirrhosis, expressed as AUROC of 0.845 (95% CI 0.722-0.968). ARFI is provided with more convenient evaluation of liver tissue condition, and its diagnostic accuracy is not significantly different from TE for staging liver fibrosis.

  15. Automatic Organ Segmentation for CT Scans Based on Super-Pixel and Convolutional Neural Networks.

    PubMed

    Liu, Xiaoming; Guo, Shuxu; Yang, Bingtao; Ma, Shuzhi; Zhang, Huimao; Li, Jing; Sun, Changjian; Jin, Lanyi; Li, Xueyan; Yang, Qi; Fu, Yu

    2018-04-20

    Accurate segmentation of specific organ from computed tomography (CT) scans is a basic and crucial task for accurate diagnosis and treatment. To avoid time-consuming manual optimization and to help physicians distinguish diseases, an automatic organ segmentation framework is presented. The framework utilized convolution neural networks (CNN) to classify pixels. To reduce the redundant inputs, the simple linear iterative clustering (SLIC) of super-pixels and the support vector machine (SVM) classifier are introduced. To establish the perfect boundary of organs in one-pixel-level, the pixels need to be classified step-by-step. First, the SLIC is used to cut an image into grids and extract respective digital signatures. Next, the signature is classified by the SVM, and the rough edges are acquired. Finally, a precise boundary is obtained by the CNN, which is based on patches around each pixel-point. The framework is applied to abdominal CT scans of livers and high-resolution computed tomography (HRCT) scans of lungs. The experimental CT scans are derived from two public datasets (Sliver 07 and a Chinese local dataset). Experimental results show that the proposed method can precisely and efficiently detect the organs. This method consumes 38 s/slice for liver segmentation. The Dice coefficient of the liver segmentation results reaches to 97.43%. For lung segmentation, the Dice coefficient is 97.93%. This finding demonstrates that the proposed framework is a favorable method for lung segmentation of HRCT scans.

  16. Scanning electron microscopy of hepatic ultrastructure: secondary, backscattered, and transmitted electron imaging.

    PubMed

    Miyai, K; Abraham, J L; Linthicum, D S; Wagner, R M

    1976-10-01

    Several methods of tissue preparation and different modes of operation of the scanning electron microscope were used to study the ultrastructure of rat liver. Rat livers were perfusion fixed with buffered 2 per cent paraformaldehyde or a mixture of 1.5 per cent paraformaldehyde and 1 per cent glutaraldehyde and processed as follows. Tissue blocks were postfixed in buffered 2 per cent osmium tetroxide followed sequentially by the ligand-mediated osmium binding technique, dehydration and cryofracture in ethanol, and critical point drying. They were then examined without metal coating in the scanning electron microscope operating in the secondary electron and backscattered electron modes. Fifty-micrometer sections were cut with a tissue sectioner, stained with lead citrate, postfixed with osmium, dehydrated, critical point dried, and examined in the secondary electron and back-scattered electron modes. Frozen sections (0.25 to 0.75 mum. thick) were cut by the method of Tokuyasu (Toluyasu KT: J Cell Biol 57:551, 1973) and their scanning transmission electron microscope images were examined either with a scanning transmission electron microscope detector or with a conversion stub using the secondary electron detector. Secondary electron images of the liver prepared by ligand-mediated osmium binding and subsequent cryofracture revealed such intracellular structures as cisternae of the endoplasmic reticulum, lysosomes, mitochondria, lipid droplets, nucleolus and nuclear chromatin, as well as the usual surface morphology, Lipocytes in the perisinusoidal space were readily identified. Backscattered electron images. Unembedded frozen sections had little drying artifact and were virtually free of freezing damage. The scanning transmission electron microscope image revealed those organelles visualized by the secondary electron mode in the ligand-mediated osmium binding-treated tissue.

  17. Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan.

    PubMed Central

    van Rossum, A. B.; Treurniet, F. E.; Kieft, G. J.; Smith, S. J.; Schepers-Bok, R.

    1996-01-01

    BACKGROUND: A study was carried out to evaluate the potential place of spiral volumetric computed tomography (SVCT) in the diagnostic strategy for pulmonary embolism. METHODS: In a prospective study 249 patients with clinical suspicion of pulmonary embolism were evaluated with various imaging techniques. In all patients a ventilation/perfusion (V/Q) scan was performed. Seventy seven patients with an abnormal V/Q scan underwent SVCT. Pulmonary angiography was then performed in all 42 patients with a non-diagnostic V/Q scan and in three patients with a high probability V/Q scan without emboli on the SVCT scan. Patients with an abnormal perfusion scan also underwent ultrasonography of the legs for the detection of deep vein thrombosis. RESULTS: One hundred and seventy two patients (69%) had a normal V/Q scan. Forty two patients (17%) had a non-diagnostic V/Q scan, and in five of these patients pulmonary emboli were found both by SVCT and pulmonary angiography. In one patient, although SVCT showed no emboli, the angiogram was positive for pulmonary embolism. In one of the 42 patients the SVCT scan showed an embolus which was not confirmed by pulmonary angiography. The other 35 patients showed no sign of emboli. Thirty five patients (14%) had a high probability V/Q scan, and in 32 patients emboli were seen on SVCT images. Two patients had both a negative SVCT scan and a negative pulmonary angiogram. In one who had an inconclusive SVCT scan pulmonary angiography was positive. The sensitivity for pulmonary embolism was 95% and the specificity 97%; the positive and negative predicted values of SVCT were 97% and 97%, respectively. CONCLUSIONS: SVCT is a relatively noninvasive test for pulmonary embolism which is both sensitive and specific and which may serve as an alternative to ventilation scintigraphy and possibly to pulmonary angiography in the diagnostic strategy for pulmonary embolism. Images PMID:8658363

  18. Non-cirrhotic portal fibrosis at a tertiary care centre in South India.

    PubMed

    Mukta, V; Panicker, Lakshmi C; Sivamani, Kalaimani; Goel, Amit; Basu, Debdutta; Dhanapathi, Halnayak

    2017-01-01

    Non-cirrhotic portal fibrosis (NCPF) is one of the important causes of upper gastrointestinal haemorrhage in patients in tropical countries. The aim of this study was to describe the clinical and laboratory profile of 68 patients with NCPF. NCPF is defined as liver disease with: (1) evidence of portal hypertension; (2) a liver biopsy showing no cirrhosis or a Tc-labelled sulphur colloid scan showing a pattern suggestive of NCPF; and (3) a patent splenoportal axis. The clinical, laboratory and demographic features of 68 patients with such criteria were studied and analysed. NCPF was common in women (73.5%) in the fourth decade of life. The median duration of illness was 24 months (range, 1 month-28 years). Patients presented to hospital with the sensation of a mass in the abdomen (50%) or with haematemesis (26.5%). They had splenomegaly (95.6%) and thrombocytopenia (88.2%). The majority of patients had normal liver function tests. Abdominal ultrasonography showed increased periportal and peri gallbladder echoes (72%), spontaneous collaterals (41.2%) and ascites (19.1%). Liver biopsy revealed portal venous sclerosis (76.3%) and periportal fibrosis (55.3%). Tc-labelled sulphur colloid scan was suggestive of NCPF in the remaining 30 cases. NCPF is common in South India. Transient ascites occurs due to decompensation of liver function after variceal bleeding and in long standing cases of NCPF. Our study used Tc-sulphur scan for diagnosing NCPF in patients where liver biopsy was contraindicated in view of severe thrombocytopenia; however, the diagnostic utility of Tc-sulphur nuclear scan to diagnose NCPF in patients with severe hypersplenism needs to be further evaluated in future studies. © The Author(s) 2016.

  19. An unanticipated diagnosis with bedside ultrasonography in patients with acute abdominal pain: rectus hematoma

    PubMed Central

    Ünlüer, Erden Erol; Kaykısız, Eylem Kuday

    2017-01-01

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and confirmed as RSH by computed tomography. Review of patient history and use of ultrasonography are important to avoid misdiagnosisof RSH. PMID:28748020

  20. The Role of Diffusion-Weighted Magnetic Resonance Imaging in the Differential Diagnosis of Simple and Hydatid Cysts of the Liver.

    PubMed

    Aksoy, S; Erdil, I; Hocaoglu, E; Inci, E; Adas, G T; Kemik, O; Turkay, R

    2018-02-01

    The present study indicates that simple and hydatid cysts in liver are a common health problem in Turkey. The aim of the study is to differentiate different types of hydatid cysts from simple cysts by using diffusion-weighted images. In total, 37 hydatid cysts and 36 simple cysts in the liver were diagnosed. We retrospectively reviewed the medical records of the patients who had both ultrasonography and magnetic resonance imaging. We measured apparent diffusion coefficient (ADC) values of all the cysts and then compared the findings. There was no statistically meaningful difference between the ADC values of simple cysts and type 1 hydatid cysts. However, for the other types of hydatid cysts, it is possible to differentiate hydatid cysts from simple cysts using the ADC values. Although in our study we cannot differentiate between type I hydatid cysts and simple cysts in the liver, diffusion-weighted images are very useful to differentiate different types of hydatid cysts from simple cysts using the ADC values.

  1. Comparison between a pediatric health promotion center and a pediatric obesity clinic in detecting metabolic syndrome and non-alcoholic fatty liver disease in children.

    PubMed

    Yang, Hye Ran; Yi, Dae Yong; Choi, Hyoung Soo

    2014-12-01

    This study was done to evaluate the efficacy of health check-ups in children in detecting metabolic syndrome and non-alcoholic fatty liver disease (NAFLD) by comparing the pediatric health promotion center with the pediatric obesity clinic. Children who visited a pediatric health promotion center (n=218) or a pediatric obesity clinic (n=178) were included. Anthropometric data, blood pressure, laboratory tests, and abdominal ultrasonography were evaluated. Two different criteria were applied to diagnose metabolic syndrome. The prevalence of metabolic syndrome in the 2 units was 3.2%-3.7% in a pediatric health promotion center and 23%-33.2% in a pediatric obesity clinic. Significant differences were observed in the prevalence of each component of metabolic syndrome between the 2 units including abdominal adiposity, blood pressure, serum triglycerides, and fasting blood glucose (P<0.05). The prevalence of NAFLD was 8.7% and 71.9% in the 2 units according to liver enzymes and 5.9% and 61.8% according to ultrasonography (P<0.05). The prevalence of metabolic syndrome and NAFLD was higher among patients visiting the obesity clinic targeting obese children than that among patients visiting the health promotion center offering routine check-ups. An obesity-oriented approach is required to prevent obesity-related health problems in children.

  2. [A case of tuberculous liver abscess developed during chemotherapy for tuberculous peritonitis as paradoxical response].

    PubMed

    Kim, Tae Kyung; Choi, Cheol Woong; Ha, Jong Kun; Jang, Hyung Ha; Park, Su Bum; Kim, Hyung Wook; Kang, Dae Hwan

    2013-07-01

    Tuberculous liver abscesses are rare. Paradoxical response in tuberculosis is common and occurred between 2 weeks and 12 weeks after anti-tuberculous medication. We report here a case of tuberculous liver abscess that developed in a paradoxical response during chemotherapy for tuberculous peritonitis in a 23-year-old male. He was hospitalized, complaining of ascites, epigastric pain. He was diagnosed tuberculous peritonitis by expiratory laparoscopic biopsy and took medication for tuberculosis. After 2 months, a hepatic lesion was detected with CT scan incidentally. Chronic granulomatous inflammation was seen in ultrasound-guided liver biopsy, and tuberculous liver abscess was diagnosed. It was considered as paradoxical response, rather than treatment failure or other else because clinical symptoms of peritoneal tuberculosis and CT scan improved. After continuing initial anti-tuberculous medication, he was successfully treated. Herein, we report a case of tuberculous liver abscess as paradoxical response while treating peritoneal tuberculosis without changing anti-tuberculous treatment regimen.

  3. Can contrast-enhanced ultrasonography improve Zone III REBOA placement for prehospital care?

    PubMed

    Chaudery, Muzzafer; Clark, James; Morrison, Jonathan J; Wilson, Mark H; Bew, Duncan; Darzi, Ara

    2016-01-01

    Torso hemorrhage is the primary cause of potentially preventable mortality in trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been advocated as an adjunct to bridge patients to definitive hemorrhage control. The primary aim of this study was to assess whether contrast-enhanced ultrasonography can improve the accuracy of REBOA placement in the infrarenal aorta (Zone III). A fluoroscopy-free "enhanced" Zone III REBOA technique was developed using a porcine cadaver model. A "standard" over-the-wire Seldinger technique was used, which was enhanced with the addition of a microbubble contrast medium to inflate the balloon, observed with ultrasonography. Following this, attending- and resident-level physicians were randomized into two groups. They were taught either the enhanced with ultrasonography guidance (Group A) or the standard measuring length of catheter insertion (Group B) technique as part of a human cadaver trauma skills course. Outcomes assessed included time (seconds) from insertion to inflation, accuracy, and missed targets. All results were benchmarked against three endovascular experts. There were 20 participants who performed REBOA with Group A (51 [31]) being significantly faster than Group B (90 [63]) (p = 0.003) and more accurate (p = 0.023) with no missed targets. Group B had five missed targets, the most common error being inflation within Zone II. For Zone III REBOA, contrast-enhanced ultrasonography technique is faster and more accurate than the standard technique. This may have value in time-critical and austere environments. Clinical studies are now required to evaluate this approach further.

  4. Evaluating Diagnostic Accuracy of Noninvasive Tests in Assessment of Significant Liver Fibrosis in Chronic Hepatitis C Egyptian Patients.

    PubMed

    Omran, Dalia; Zayed, Rania A; Nabeel, Mohammed M; Mobarak, Lamiaa; Zakaria, Zeinab; Farid, Azza; Hassany, Mohamed; Saif, Sameh; Mostafa, Muhammad; Saad, Omar Khalid; Yosry, Ayman

    2018-05-01

    Stage of liver fibrosis is critical for treatment decision and prediction of outcomes in chronic hepatitis C (CHC) patients. We evaluated the diagnostic accuracy of transient elastography (TE)-FibroScan and noninvasive serum markers tests in the assessment of liver fibrosis in CHC patients, in reference to liver biopsy. One-hundred treatment-naive CHC patients were subjected to liver biopsy, TE-FibroScan, and eight serum biomarkers tests; AST/ALT ratio (AAR), AST to platelet ratio index (APRI), age-platelet index (AP index), fibrosis quotient (FibroQ), fibrosis 4 index (FIB-4), cirrhosis discriminant score (CDS), King score, and Goteborg University Cirrhosis Index (GUCI). Receiver operating characteristic curves were constructed to compare the diagnostic accuracy of these noninvasive methods in predicting significant fibrosis in CHC patients. TE-FibroScan predicted significant fibrosis at cutoff value 8.5 kPa with area under the receiver operating characteristic (AUROC) 0.90, sensitivity 83%, specificity 91.5%, positive predictive value (PPV) 91.2%, and negative predictive value (NPV) 84.4%. Serum biomarkers tests showed that AP index and FibroQ had the highest diagnostic accuracy in predicting significant liver fibrosis at cutoff 4.5 and 2.7, AUROC was 0.8 and 0.8 with sensitivity 73.6% and 73.6%, specificity 70.2% and 68.1%, PPV 71.1% and 69.8%, and NPV 72.9% and 72.3%, respectively. Combined AP index and FibroQ had AUROC 0.83 with sensitivity 73.6%, specificity 80.9%, PPV 79.6%, and NPV 75.7% for predicting significant liver fibrosis. APRI, FIB-4, CDS, King score, and GUCI had intermediate accuracy in predicting significant liver fibrosis with AUROC 0.68, 0.78, 0.74, 0.74, and 0.67, respectively, while AAR had low accuracy in predicting significant liver fibrosis. TE-FibroScan is the most accurate noninvasive alternative to liver biopsy. AP index and FibroQ, either as individual tests or combined, have good accuracy in predicting significant liver fibrosis

  5. High-resolution ultrasonography in assessment of nail-related disorders.

    PubMed

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  6. Fatal Liver Cyst Rupture Due to Anabolic Steroid Use: A Case Presentation.

    PubMed

    Hansma, Patrick; Diaz, Francisco J; Njiwaji, Chantel

    2016-03-01

    Liver cysts are commonly found incidentally from imaging scans or at autopsy. These benign neoplasms vary in size and represent a heterogeneous group of disorders, for which the demographics, risk factors, apparent inciting event, clinical presentation, and outcome are varied. Complications that can develop from a liver cyst include development of spontaneous hemorrhage, infection, and/or obstruction. Although the etiology of liver cysts varies, fatal rupture of a hemorrhagic liver cyst due to anabolic steroid use is a rare occurrence. In fact, there are few reported cases in journal literature. We report a case of a fatal liver cyst rupture with resultant hemoperitoneum in the presence of anabolic steroid (stanozolol) use.

  7. WE-D-17A-03: Improvement of Accuracy of Spot-Scanning Proton Beam Delivery for Liver Tumor by Real-Time Tumor-Monitoring and Gating System: A Simulation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuura, T; Shimizu, S; Miyamoto, N

    2014-06-15

    Purpose: To improve the accuracy of spot-scanning proton beam delivery for target in motion, a real-time tumor-monitoring and gating system using fluoroscopy images was developed. This study investigates the efficacy of this method for treatment of liver tumors using simulation. Methods: Three-dimensional position of a fiducial marker inserted close to the tumor is calculated in real time and proton beam is gated according to the marker's distance from the planned position (Shirato, 2012). The efficient beam delivery is realized even for the irregular and sporadic motion signals, by employing the multiple-gated irradiations per operation cycle (Umezawa, 2012). For each ofmore » two breath-hold CTs (CTV=14.6cc, 63.1cc), dose distributions were calculated with internal margins corresponding to freebreathing (FB) and real-time gating (RG) with a 2-mm gating window. We applied 8 trajectories of liver tumor recorded during the treatment of RTRT in X-ray therapy and 6 initial timings. Dmax/Dmin in CTV, mean liver dose (MLD), and irradiation time to administer 3 Gy (RBE) dose were estimated assuming rigid motion of targets by using in-house simulation tools and VQA treatment planning system (Hitachi, Ltd., Tokyo). Results: Dmax/Dmin was degraded by less than 5% compared to the prescribed dose with all motion parameters for smaller CTV and less than 7% for larger CTV with one exception. Irradiation time showed only a modest increase if RG was used instead of FB; the average value over motion parameters was 113 (FB) and 138 s (RG) for smaller CTV and 120 (FB) and 207 s (RG) for larger CTV. In RG, it was within 5 min for all but one trajectory. MLD was markedly decreased by 14% and 5–6% for smaller and larger CTVs respectively, if RG was applied. Conclusions: Spot-scanning proton beam was shown to be delivered successfully to liver tumor without much lengthening of treatment time. This research was supported by the Cabinet Office, Government of Japan and the Japan

  8. Assessment of hemodynamics in a rat model of liver cirrhosis with precancerous lesions using multislice spiral CT perfusion imaging.

    PubMed

    Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng

    2013-01-01

    To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P < 0.05) but significantly decreased hepatic portal perfusion and mean transit time (P < 0.05). Multislice spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.

  9. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    PubMed

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  10. Solitary Fibrous Tumor in the Round Ligament of the Liver: A Fortunate Intraoperative Discovery

    PubMed Central

    Beyer, Laura; Delpero, Jean-Robert; Chetaille, Bruno; Sarran, Anthony; Perrot, Delphine; Moureau-Zabotto, Laurence; Guiramand, Jérôme; Bertucci, François

    2012-01-01

    Solitary fibrous tumors (SFTs) are mesenchymal neoplasms of fibroblastic origin, most commonly found in the pleura. Numerous extrathoracic locations have been reported during the last 2 decades. Herein, we report the first case of an SFT in the round ligament of the liver. A 46-year-old Caucasian man presented with a 12-month history of abdominal pain. An ultrasonography-guided microbiopsy first revealed a desmoid tumor. After failure of first- and second-line medical treatments (celecoxib and tamoxifen, then imatinib), histological reexamination was suspicious for a low-grade sarcoma. MRI was also suspicious for a malignant process. Hence, surgery was decided. Laparotomy found a huge and well-limited tumor that, unexpectedly, was appended to the round ligament of the liver and free from any other intra-abdominal contact. The tumor was easily removed. Excision was monobloc and macroscopically complete. Histological analysis diagnosed an SFT arising from the round ligament of the liver. No adjuvant treatment was given. Ten months after surgery, the patient is alive without any signs or symptoms of relapse. This is the first report of SFT arising from the round ligament of the liver. It illustrates the difficulty in diagnosing such tumors. Whilst diagnosis of SFT is rare, it should be kept in mind to allow early diagnosis and complete surgical resection, which provide the best chance for recovery. PMID:22666211

  11. Solitary fibrous tumor in the round ligament of the liver: a fortunate intraoperative discovery.

    PubMed

    Beyer, Laura; Delpero, Jean-Robert; Chetaille, Bruno; Sarran, Anthony; Perrot, Delphine; Moureau-Zabotto, Laurence; Guiramand, Jérôme; Bertucci, François

    2012-01-01

    Solitary fibrous tumors (SFTs) are mesenchymal neoplasms of fibroblastic origin, most commonly found in the pleura. Numerous extrathoracic locations have been reported during the last 2 decades. Herein, we report the first case of an SFT in the round ligament of the liver. A 46-year-old Caucasian man presented with a 12-month history of abdominal pain. An ultrasonography-guided microbiopsy first revealed a desmoid tumor. After failure of first- and second-line medical treatments (celecoxib and tamoxifen, then imatinib), histological reexamination was suspicious for a low-grade sarcoma. MRI was also suspicious for a malignant process. Hence, surgery was decided. Laparotomy found a huge and well-limited tumor that, unexpectedly, was appended to the round ligament of the liver and free from any other intra-abdominal contact. The tumor was easily removed. Excision was monobloc and macroscopically complete. Histological analysis diagnosed an SFT arising from the round ligament of the liver. No adjuvant treatment was given. Ten months after surgery, the patient is alive without any signs or symptoms of relapse. This is the first report of SFT arising from the round ligament of the liver. It illustrates the difficulty in diagnosing such tumors. Whilst diagnosis of SFT is rare, it should be kept in mind to allow early diagnosis and complete surgical resection, which provide the best chance for recovery.

  12. Association of nonalcoholic fatty liver disease with low bone mass in postmenopausal women.

    PubMed

    Moon, Seong-Su; Lee, Young-Sil; Kim, Sung Woo

    2012-10-01

    Osteoporosis is a disease associated with insulin resistant states such as central obesity, diabetes, and metabolic syndrome. Non-alcoholic fatty liver disease (NAFLD) is also increased in such conditions. However, little is known about whether osteoporosis and nonalcoholic fatty liver disease are etiologically related to each other or not. We examined whether bone mineral density (BMD) is associated with NAFLD in pre- and postmenopausal women. Four hundred eighty-one female subjects (216 premenopausal and 265 postmenopausal) were enrolled. Lumbar BMD was measured using dual-energy X-ray absorptiometry. Liver ultrasonography was done to check the severity of fatty liver. We excluded subjects with a secondary cause of liver disease. Blood pressure, lipid profile, fasting plasma glucose, alanine aminotransferase (ALT), aspartate aminotransferase, and body mass index were measured in every subject. Mean lumbar BMD was lower in subjects with NAFLD than those without NAFLD in postmenopausal women (0.98 ± 0.01 vs. 1.01 ± 0.02 g/cm², P = 0.046). Multiple correlation analysis revealed a significant association between mean lumbar BMD and NAFLD in postmenopausal subjects after adjusting for age, body mass index, ALT, smoking status, and alcohol consumption (β coefficient -0.066, 95% CI -0.105 to -0.027, P = 0.001). Even after adjusting the presence of metabolic syndrome, the significance was maintained (β coefficient -0.043, 95% CI -0.082 to -0.004, P = 0.031). Lumbar BMD is related with NAFLD in postmenopausal females. We suggest that postmenopausal women with NAFLD may have a higher risk of osteoporosis than those without.

  13. Comparison of ultrasonography and physical examination in the diagnosis of incisional hernia in a prospective study.

    PubMed

    Bloemen, A; van Dooren, P; Huizinga, B F; Hoofwijk, A G M

    2012-02-01

    Incisional hernia is a frequent complication of abdominal surgery (incidence 2-20%). Diagnosis by physical examination is sometimes difficult, especially in small incisional hernias or in obese patients. The additional diagnostic value of standardized ultrasonography was evaluated in this prospective study. A total of 456 patients participating in a randomized trial comparing two suture materials for closure of the abdominal fascia underwent physical examination and ultrasonography at 6-month intervals. Wound complaints and treatment of incisional hernia were also noted. Statistical analysis was performed using the Chi-squared and Fisher's exact tests (SPSS). Interest variability analysis was performed. During a median follow-up of 31 months, 103 incisional hernias were found. A total of 82 incisional hernias were found by physical examination and an additional 21 with ultrasonography. Six of these additional hernias were symptomatic and only one of the additional hernias received operative treatment. The false-negative rates for physical examination and ultrasonography were 25.3 and 24.4%, respectively. Interest variability was low, with a Kappa of 0.697 (P < 0.001). There are no clear diagnostic criteria for incisional hernia available in the literature. Standardized combination of ultrasonography with physical examination during follow-up yields a significant number of, mostly asymptomatic, hernias, which would not be found using physical examination alone. This is especially relevant in research settings.

  14. Preliminary study on liver function changes after trisectionectomy with versus without prior portal vein embolization.

    PubMed

    Malinowski, Maciej; Lock, Johan Friso; Seehofer, Daniel; Gebauer, Bernhard; Schulz, Antje; Demirel, Lina; Bednarsch, Jan; Stary, Victoria; Neuhaus, Peter; Stockmann, Martin

    2016-09-01

    Post-hepatectomy liver failure (PHLF) is the major risk factor for mortality after hepatectomy. Preoperative planning of the future liver remnant volume reduces PHLF rates; however, future liver remnant function (FLR-F) might have an even stronger predictive value. In this preliminary study, we used a new method to calculate FLR-F by the LiMAx test and computer tomography-assisted volumetric-analysis to visualize liver function changes after portal vein embolization (PVE) before extended hepatectomy. The subjects included patients undergoing extended right hepatectomy either directly (NO-PVE group) or after PVE (PVE group). Computed tomography (CT) scan and liver function tests (LiMAx) were done before PVE and preoperatively. FLR-F was calculated and correlated with the postoperative liver function. There were 12 patients in the NO-PVE group and 19 patients in the PVE group. FLR-F and postoperative liver function correlated significantly in both groups (p = 0.036, p = 0.011), although postoperative liver function was slightly overestimated, at 32 and 45 µg/kg/min, in the NO-PVE and PVE groups, respectively. LiMAx value did not change after PVE. Volume-function analysis using LiMAx and CT scan enables us to reliably predict early postoperative liver function. Global enzymatic liver function measured by the LiMAx test did not change after PVE, confirming that liver function distribution in the liver stays constant after PVE. An overestimation of FLR-F is needed to compensate for the intraoperative liver injury that occurs in patients undergoing extended hepatectomy.

  15. In-utero diagnosis of Norrie disease by ultrasonography.

    PubMed

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  16. Does ultrasonography accurately diagnose acute cholecystitis? Improving diagnostic accuracy based on a review at a regional hospital

    PubMed Central

    Hwang, Hamish; Marsh, Ian; Doyle, Jason

    2014-01-01

    Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607

  17. Concepts and Preliminary Data Toward the Realization of Image-guided Liver Surgery

    PubMed Central

    Cash, David M.; Miga, Michael I.; Glasgow, Sean C.; Dawant, Benoit M.; Clements, Logan W.; Cao, Zhujiang; Galloway, Robert L.; Chapman, William C.

    2013-01-01

    Image-guided surgery provides navigational assistance to the surgeon by displaying the surgical probe position on a set of preoperative tomograms in real time. In this study, the feasibility of implementing image-guided surgery concepts into liver surgery was examined during eight hepatic resection procedures. Preoperative tomographic image data were acquired and processed. Accompanying intraoperative data on liver shape and position were obtained through optically tracked probes and laser range scanning technology. The preoperative and intraoperative representations of the liver surface were aligned using the iterative closest point surface matching algorithm. Surface registrations resulted in mean residual errors from 2 to 6 mm, with errors of target surface regions being below a stated goal of 1 cm. Issues affecting registration accuracy include liver motion due to respiration, the quality of the intraoperative surface data, and intraoperative organ deformation. Respiratory motion was quantified during the procedures as cyclical, primarily along the cranial–caudal direction. The resulting registrations were more robust and accurate when using laser range scanning to rapidly acquire thousands of points on the liver surface and when capturing unique geometric regions on the liver surface, such as the inferior edge. Finally, finite element models recovered much of the observed intraoperative deformation, further decreasing errors in the registration. Image-guided liver surgery has shown the potential to provide surgeons with important navigation aids that could increase the accuracy of targeting lesions and the number of patients eligible for surgical resection. PMID:17458587

  18. Non-invasive imaging techniques in assessing non-alcoholic fatty liver disease: a current status of available methods

    PubMed Central

    Lăpădat, AM; Jianu, IR; Ungureanu, BS; Florescu, LM; Gheonea, DI; Sovaila, S; Gheonea, IA

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is an ailment affecting and increasing a number of people worldwide diagnosed via non-invasive imaging techniques, at a time when a minimum harm caused by medical procedures is rightfully emphasized, more sought after, than ever before. Liver steatosis should not be taken lightly even if its evolution is largely benign as it has the potential to develop into non-alcoholic steatohepatitis (NASH) or even more concerning, hepatic cirrhosis, and hepatocellular carcinoma (HCC). Traditionally, liver biopsy has been the standard for diagnosing this particular liver disease, but nowadays, a consistent number of imagistic methods are available for diagnosing hepatosteatosis and choosing the one appropriate to the clinical context is the key. Although different in sensitivity and specificity when it comes to determining the hepatic fat fraction (FF), these imaging techniques possessing a diverse availability, operating difficulty, cost, and reproducibility are invaluable to any modern physician. Ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI), elastography, and spectroscopy will be discussed in order to lay out the advantages and disadvantages of their diagnostic potential and application. Although imagistics has given physicians a valuable insight into the means of managing NAFLD, the current methods are far from perfect, but given the time, they will surely be improved and the use of liver biopsy will be completely removed. PMID:28255371

  19. [Prevalence of non-alcoholic fatty liver disease in a population with elevated transaminases and level of accuracy of the diagnosis in Primary Care].

    PubMed

    Samperio-González, María Amelia; Selvi-Blasco, Marta; Manzano-Montero, Mónica; Méndez-Gómez, Judit; Gil-Prades, Montserrat; Azagra, Rafael

    2016-05-01

    Nonalcoholic fatty liver disease (NAFLD) is the most common cause of elevated transaminases in adults. Determine the prevalence of NASH in patients with sustained hypertransaminasemia, and Know the adequacy of the registered in Primary Care (AP) diagnosis. 1) Cross-sectional study with a random sample of patients with elevated alanine aminotransferase (ALT) held (ALT> 32 for ≥6 months), ruling out other causes of liver disease, according to clinical, laboratory and ultrasound scan criteria in AP and 2) cross-sectional description of all cases diagnosed with NASH recorded (K76 - ICD10) with diagnostic adequacy analysis according to standard criteria. 290 patients were analyzed: 76 were diagnosed as NASH (26.1%), 44 women (57.9%). Multivariate analysis adjusted for age and sex showed no association between NASH and male gender (OR: 0.5; CI95%: 0.3-0.9), diabetes mellitus (DM) (OR: 2.42; CI95%: 1.2-4.9) and hypertension blood pressure (HBP) (OR: 3.07; CI 95% 1.6-5.6). Of the 209 diagnosed with NASH record: 51 (24.4%) met the criteria for NASH. The rest had insufficient records. 53.1% lacked sustained hypertransaminasemia; 48% of viral serology; 11% supported and 53.1% abdominal ultrasound registration of alcohol. Severe NASH is frequent among patients with sustained hypertransaminasemia. The DM and hypertension significantly increase the risk of NASH. The diagnosis of NASH is recorded without considering all criteria and mainly NASH made by ultrasonography. They should unify diagnostic criteria in the register of NASH. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  20. Optimized efficient liver T1ρ mapping using limited spin lock times

    NASA Astrophysics Data System (ADS)

    Yuan, Jing; Zhao, Feng; Griffith, James F.; Chan, Queenie; Wang, Yi-Xiang J.

    2012-03-01

    T1ρ relaxation has recently been found to be sensitive to liver fibrosis and has potential to be used for early detection of liver fibrosis and grading. Liver T1ρ imaging and accurate mapping are challenging because of the long scan time, respiration motion and high specific absorption rate. Reduction and optimization of spin lock times (TSLs) are an efficient way to reduce scan time and radiofrequency energy deposition of T1ρ imaging, but maintain the near-optimal precision of T1ρ mapping. This work analyzes the precision in T1ρ estimation with limited, in particular two, spin lock times, and explores the feasibility of using two specific operator-selected TSLs for efficient and accurate liver T1ρ mapping. Two optimized TSLs were derived by theoretical analysis and numerical simulations first, and tested experimentally by in vivo rat liver T1ρ imaging at 3 T. The simulation showed that the TSLs of 1 and 50 ms gave optimal T1ρ estimation in a range of 10-100 ms. In the experiment, no significant statistical difference was found between the T1ρ maps generated using the optimized two-TSL combination and the maps generated using the six TSLs of [1, 10, 20, 30, 40, 50] ms according to one-way ANOVA analysis (p = 0.1364 for liver and p = 0.8708 for muscle).

  1. Primary perivascular epithelioid cell tumour (PEComa) of the liver.

    PubMed

    Cheung, Tan To; Trendell-Smith, Nigel; Poon, Ronnie T P

    2013-07-10

    We present a case of a 53-year-old woman with abdominal discomfort for 6 months. The liver was enlarged. Contrast CT scan of the abdomen revealed a 10 cm hypervascular tumour at the right lobe of the liver. Right hepatectomy with complete excision of the tumour was achieved. Histological and immunohistochemical findings were consistent with perivascular epithelioid cell tumour. She is regularly followed up with contrast CT assessment. There is no tumour recurrence 12 months after the operation.

  2. Variants and pitfalls on radioiodine scans in pediatric patients with differentiated thyroid carcinoma.

    PubMed

    Mostafa, Mohamed; Vali, Reza; Chan, Jeffrey; Omarkhail, Yusuaf; Shammas, Amer

    2016-10-01

    Potentially false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma can mimic functioning thyroid tissue and functioning thyroid carcinomatous tissue. Such false-positive findings comprise variants and pitfalls that can vary slightly in children as compared with adults. To determine the patterns and frequency of these potential false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma. We reviewed a total of 223 radioiodine scans from 53 pediatric patients (mean age 13.3 years, 37 girls) with differentiated thyroid carcinoma. Focal or regional activity that likely did not represent functioning thyroid tissue or functioning thyroid carcinomatous tissue were categorized as variants or pitfalls. The final diagnosis was confirmed by reviewing the concurrent and follow-up clinical data, correlative ultrasonography, CT scanning, serum thyroglobulin and antithyroglobulin antibody levels. We calculated the frequency of these variants and pitfalls from diagnostic and post-therapy radioiodine scans. The most common variant on the radioiodine scans was the thymic activity (24/223, 10.8%) followed by the cardiac activity (8/223, 3.6%). Salivary contamination and star artifact, caused by prominent thyroid remnant, were the most important observed pitfalls. Variants and pitfalls that mimic functioning thyroid tissue or functioning thyroid carcinomatous tissue on radioiodine scan in children with differentiated thyroid carcinoma are not infrequent, but they decrease in frequency on successive radioiodine scans. Potential false-positive findings can be minimized with proper knowledge of the common variants and pitfalls in children and correlation with clinical, laboratory and imaging data.

  3. Role of ultrasonography in the differential diagnosis of thyrotoxicosis: a noninvasive, cost-effective, and widely available but underutilized diagnostic tool.

    PubMed

    Alzahrani, Ali S; Ceresini, Graziano; Aldasouqi, Saleh A

    2012-01-01

    To explore the use of ultrasonography as a diagnostic alternative to the traditional "gold standard" imaging study of nuclear scintigraphy in the evaluation of thyrotoxicosis. We review the relevant literature and share our own experience to highlight the promising role of ultrasonography in thyrotoxicosis. In addition, we present a diagnostic algorithm suggesting liberal use of ultrasonography in the evaluation of thyrotoxicosis. Ultrasonography has proved effective not only in the differentiation of Graves disease from other types and causes of thyrotoxicosis but also in the detection of subtle thyroid nodules. The latter role is emphasized in light of the recent observation of an increased risk of occurrence of papillary thyroid carcinoma in patients with Graves disease. Ultrasonography is a cost-effective, noninvasive, portable, and safe imaging modality in the evaluation of thyrotoxicosis, both for physiologic assessment and for detection of nonpalpable thyroid cancers that may elude identification on physical examination and nuclear imaging studies. Although thyroid scintigraphy remains a standard radiologic study, thyroid ultrasonography can be a practical alternative in many cases and the primary imaging modality in some situations such as during pregnancy and lactation and for evaluation and management of amiodarone-induced thyrotoxicosis.

  4. “Nodule in Nodule” on Thyroid Ultrasonography: Possibility of Follicular Carcinoma Transformed from Benign Thyroid Tumor

    PubMed Central

    Kobayashi, Kaoru; Ota, Hisashi; Hirokawa, Mitsuyoshi; Yabuta, Tomonori; Fukushima, Mitsuhiro; Masuoka, Hiroo; Higashiyama, Takuya; Kihara, Minoru; Ito, Yasuhiro; Miya, Akihiro; Miyauchi, Akira

    2017-01-01

    Background It is generally considered impossible to differentiate follicular carcinomas from follicular adenomas by means of ultrasonography or cytology before surgery. Therefore, follicular carcinoma is histopathologically diagnosed by verifying capsular and/or vascular invasion after surgery. However, ultrasonography may play an important role in diagnosing follicular carcinoma preoperatively in a small number of cases. Case Description Four cases of follicular carcinoma or follicular neoplasm that transformed from a benign thyroid tumor and demonstrated a “nodule in nodule” appearance on ultrasonography are presented in this report. Characteristic ultrasound features of such patients are: (1) a “nodule in nodule” appearance, (2) a well-defined boundary line between the nodules, and (3) separate distribution of blood signals within each nodule. Conclusion A small number of patients with follicular carcinomas or follicular neoplasms may present with a “nodule in nodule” appearance on ultrasonography. It was suggested a long time ago that follicular carcinomas may develop from benign thyroid tumors. The fact that follicular carcinomas appear within benign tumors may be evidence of thyroid tumorigenesis. PMID:28589092

  5. Current consensus and guidelines of contrast enhanced ultrasound for the characterization of focal liver lesions

    PubMed Central

    Jang, Jae Young; Kim, Moon Young; Jeong, Soung Won; Kim, Tae Yeob; Kim, Seung Up; Lee, Sae Hwan; Suk, Ki Tae; Park, Soo Young; Woo, Hyun Young; Kim, Sang Gyune; Heo, Jeong; Baik, Soon Koo; Kim, Hong Soo

    2013-01-01

    The application of ultrasound contrast agents (UCAs) is considered essential when evaluating focal liver lesions (FLLs) using ultrasonography (US). Microbubble UCAs are easy to use and robust; their use poses no risk of nephrotoxicity and requires no ionizing radiation. The unique features of contrast enhanced US (CEUS) are not only noninvasiveness but also real-time assessing of liver perfusion throughout the vascular phases. The later feature has led to dramatic improvement in the diagnostic accuracy of US for detection and characterization of FLLs as well as the guidance to therapeutic procedures and evaluation of response to treatment. This article describes the current consensus and guidelines for the use of UCAs for the FLLs that are commonly encountered in US. After a brief description of the bases of different CEUS techniques, contrast-enhancement patterns of different types of benign and malignant FLLs and other clinical applications are described and discussed on the basis of our experience and the literature data. PMID:23593604

  6. Anticoagulation and high dose liver radiation. A preliminary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lightdale, C.J.; Wasser, J.; Coleman, M.

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes onmore » liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted.« less

  7. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center

    PubMed Central

    2012-01-01

    Background This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. Methods The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. Results The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Conclusions Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed. PMID:22691418

  8. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

    PubMed

    Kim, Hyung Min; So, Byung Hak; Jeong, Won Jung; Choi, Se Min; Park, Kyu Nam

    2012-06-12

    This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed.

  9. Comparing Magnetic Resonance Imaging and High-Resolution Dynamic Ultrasonography for Diagnosis of Plantar Plate Pathology: A Case Series.

    PubMed

    Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael

    Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in

  10. Return to contact sports following infectious mononucleosis: the role of serial ultrasonography.

    PubMed

    O'Connor, Tony E; Skinner, Liam J; Kiely, Patrick; Fenton, John E

    2011-08-01

    Splenic rupture is a rare but potentially fatal complication of infectious mononucleosis. Athletes returning to contact sports following infectious mononucleosis are at potential risk of splenic rupture secondary to abdominal trauma. No clear consensus exists as to when it is safe to allow these athletes to return to contact sports. Suggested periods of abstinence have ranged from 2 weeks to 6 months. We outline our experiences with the use of abdominal ultrasonography at 1 month after the diagnosis of infectious mononucleosis as a means of determining when athletes can safely return to contact sports. Our study group was made up of 19 such patients (mean age: 16.7 yr). We found that 16 of these patients (84%) had normal splenic dimensions on ultrasonography 1 month after diagnosis, and they were therefore allowed to return to contact sports. While the remaining 3 patients had an enlarged spleen at 1 month, their splenic dimensions had all returned to normal when ultrasonographic examination was repeated at 2 months postdiagnosis. We conclude that serial abdominal ultrasonography allows for informed decision making in determining when athletes can safely return to contact sports following infectious mononucleosis.

  11. Inverse Association between Hepatitis B Virus Infection and Fatty Liver Disease: A Large-Scale Study in Populations Seeking for Check-Up

    PubMed Central

    Cheng, Yuan-Lung; Wang, Yuan-Jen; Kao, Wei-Yu; Chen, Ping-Hsien; Huo, Teh-Ia; Huang, Yi-Hsiang; Lan, Keng-Hsin; Su, Chien-Wei; Chan, Wan-Leong; Lin, Han-Chieh; Lee, Fa-Yauh; Wu, Jaw-Ching

    2013-01-01

    Background Although many studies have attempted to clarify the association between hepatitis B virus (HBV) infection and fatty liver disease, no prior studies have emphasized the relationship of HBV and fatty liver regarding different demographics of age and body mass index (BMI). Aim To investigate the correlation of HBV and fatty liver in the different demographics of age and BMI. Methods We enrolled consecutive subjects who had received health check-up services at the Taipei Veterans General Hospital from 2002 to 2009 and ultrasonography was used to diagnose fatty liver according to the practice guidelines of the American Gastroenterological Association. Results Among the 33,439 subjects enrolled in this study, fatty liver was diagnosed in 43.9% of the population and 38.9% of patients with chronic HBV infection. Multivariate analysis showed that BMI, age, waist circumference, systolic blood pressure, fasting glucose, cholesterol, alanine aminotransferase (ALT) levels, and platelet counts were positively associated, while hepatitis B surface antigen (HBsAg) positivity was inversely associated with fatty liver, especially for subjects with BMI>22.4 kg/m2 and age>50 years. On the contrary, HBV infection was positively correlated with the presence of elevated serum ALT levels in subjects with fatty liver disease regardless of their age and BMI. Conclusions Metabolic factors are important determinants for the prevalence of fatty liver. Patients with HBV infection were inversely associated with fatty liver disease than the general population, especially in older and obese patients. Furthermore, metabolic factors and HBV infection were associated with elevated serum ALT levels in fatty liver disease. PMID:23991037

  12. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    PubMed

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  13. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja)

    PubMed Central

    de Moraes, Wanderlei; Ferreira, Thiago A.C.; Somma, André T.; Cubas, Zalmir S.; Moore, Bret A.; Montiani-Ferreira, Fabiano

    2017-01-01

    Twenty harpy eagles (Harpia harpyja) without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI) and pulsatility index (PI) were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation. PMID:28540254

  14. Relationship between Non-Alcoholic Fatty Liver Disease and Breast Cancer.

    PubMed

    Nseir, William; Abu-Rahmeh, Zuhair; Tsipis, Alex; Mograbi, Julnar; Mahamid, Mahmud

    2017-04-01

    Non-alcoholic fatty liver disease (NAFLD) is a chronic liver disease which refers to the presence of hepatic steatosis. Breast cancer is now the most common cancer in women and is the leading cause of death from cancer among women. To assess the relationship between NAFLD and newly diagnosed cases of breast cancer. The results of mammography screening examinations in women referred to the Breast Center, Holy Family Hospital, Nazareth during a 4 year period were collected. We identified cases of women who were newly diagnosed with breast cancer and who underwent abdominal computed tomography (CT) within 1 month of the diagnosis. The control group comprised 73 women with normal mammography and breast ultrasonography who underwent abdominal CT within 3 months from the date of the breast cancer screening during the same study period. The control cases were matched by age and body mass index (BMI). We compared the cases with the controls in terms of the presence of diffuse hepatic fatty liver and other known risk factors for breast cancer. Of the 133 women who were screened, 73 with new diagnosis of breast cancer were eligible for the study. NAFLD was found in 33 of the women with breast cancer and in 12 in the control group (45.2% vs.16.4%, respectively, P = 0.002). Multivariate analysis showed NAFLD (odds ratio 2.82, 95% confidence interval 1.2-5.5, P = 0.016) to be associated with breast cancer. NAFLD is associated with breast cancer.

  15. Patient-specific and global convolutional neural networks for robust automatic liver tumor delineation in follow-up CT studies.

    PubMed

    Vivanti, Refael; Joskowicz, Leo; Lev-Cohain, Naama; Ephrat, Ariel; Sosna, Jacob

    2018-03-10

    Radiological longitudinal follow-up of tumors in CT scans is essential for disease assessment and liver tumor therapy. Currently, most tumor size measurements follow the RECIST guidelines, which can be off by as much as 50%. True volumetric measurements are more accurate but require manual delineation, which is time-consuming and user-dependent. We present a convolutional neural networks (CNN) based method for robust automatic liver tumor delineation in longitudinal CT studies that uses both global and patient specific CNNs trained on a small database of delineated images. The inputs are the baseline scan and the tumor delineation, a follow-up scan, and a liver tumor global CNN voxel classifier built from radiologist-validated liver tumor delineations. The outputs are the tumor delineations in the follow-up CT scan. The baseline scan tumor delineation serves as a high-quality prior for the tumor characterization in the follow-up scans. It is used to evaluate the global CNN performance on the new case and to reliably predict failures of the global CNN on the follow-up scan. High-scoring cases are segmented with a global CNN; low-scoring cases, which are predicted to be failures of the global CNN, are segmented with a patient-specific CNN built from the baseline scan. Our experimental results on 222 tumors from 31 patients yield an average overlap error of 17% (std = 11.2) and surface distance of 2.1 mm (std = 1.8), far better than stand-alone segmentation. Importantly, the robustness of our method improved from 67% for stand-alone global CNN segmentation to 100%. Unlike other medical imaging deep learning approaches, which require large annotated training datasets, our method exploits the follow-up framework to yield accurate tumor tracking and failure detection and correction with a small training dataset. Graphical abstract Flow diagram of the proposed method. In the offline mode (orange), a global CNN is trained as a voxel classifier to segment liver

  16. Sensitivity and specificity of ultrasonography and low-field magnetic resonance imaging for diagnosing arthritis.

    PubMed

    Broll, Matthias; Albrecht, Katinka; Tarner, Ingo; Müller-Ladner, Ulf; Strunk, Johannes

    2012-01-01

    To evaluate the value of grey-scale ultrasonography (US) including power Doppler ultrasonography (PDUS) and low-field magnetic resonance imaging (MRI) for the diagnosis of arthritis in a diagnostic phase III study. Fifty consecutive patients with suspected arthritis were included in the study. Following a standardised protocol, US of the carpus and the metacarpophalangeal (MCP) joints of the dominant hand was performed. Subsequently, low-field MRI was done using standard sequences, with contrast agent (Gadolinium DTPA) administered to 29 patients. In 32 out of 50 patients a clinical diagnosis of arthritis was established. In grey-scale ultrasonography including PDUS, sensitivity and specificity were determined as 0.94 and 0.5, respectively, for synovitis (effusion and hypertrophy), 0.72 and 0.94, respectively, for Doppler signals, and 0.38 and 1.0, respectively, for bone erosions. In low-field MRI, sensitivity and specificity values were 0.77 and 0.75, respectively, for synovitis (when using contrast agent), 0.48 and 0.78, respectively, for bone marrow oedema, and 0.58 and 0.83, respectively, for bone erosion. Both grey-scale ultrasonography including PDUS and low-field MRI are suitable imaging methods for diagnosing arthritis at an early stage. However, PDUS displays a higher specificity and almost the same sensitivity as compared to contrast-enhanced MRI, while being a much simpler and less costly procedure.

  17. Score of liver ultrasonography predicts treatment-related severe neutropenia and neutropenic fever in induction chemotherapy with docetaxel for locally advanced head and neck cancer patients with normal serum transamines.

    PubMed

    Wang, Ting-Yao; Chen, Wei-Ming; Yang, Lan-Yan; Chen, Chao-Yu; Chou, Wen-Chi; Chen, Yi-Yang; Chen, Chih-Cheng; Lee, Kuan-Der; Lu, Chang-Hsien

    2016-11-01

    Induction chemotherapy with docetaxel improved outcome in advanced head and neck squamous cell carcinoma (HNSCC) patients, but docetaxel was not recommended in liver dysfunction patients for treatment toxicities. Severe neutropenic events (SNE) including severe neutropenia (SN) and febrile neutropenia (FN) still developed in these patients with normal serum transaminases. Ultrasonography (US) fibrotic score represented degree of hepatic parenchymal damage and showed good correlation to fibrotic changes histologically. This study aims to evaluate the association of US fibrotic score with docetaxel treatment-related SNE in advanced HNSCC patients with normal serum transaminases. Between 1 January 2011 and 31 December 2013, a total of 47 advanced HNSCC patients treated with induction docetaxel were enrolled. The clinical features were collected to assess predictive factors for SNE. The patients were divided into two groups by the US fibrotic score with a cutoff value of 7. The Mann-Whitney U test and logistic regression method were used for the risk factor analysis. The background, treatment, and response were similar in both groups except for lower lymphocyte and platelet count in patients with higher US score. Twenty-seven patients (51 %) developed grade 3/4 neutropenia, and more SNE developed in patients with US score ≧7. In multivariate analysis, only US score ≥7 was independent predictive factor for developing SN (hazard ratio 7.71, p = 0.043) and FN (hazard ratio 20.95, p = 0.008). US score ≥7 is an independent risk factor for SNE in advanced HNSCC patients treated with induction docetaxel. US score could be used for risk prediction of docetaxel-related SNE.

  18. Progress of liver resection for hepatocellular carcinoma in Taiwan.

    PubMed

    Wu, Cheng-Chung

    2017-05-01

    Taiwan is a well-known endemic area of hepatitis B. Hepatocellular carcinoma (HCC) has consistently been the first or second highest cause of cancer death over the past 20 years. This review article describes the progress of liver resection for HCC in Taiwan in the past half century. The mortality rate for HCC resection was 15-30% in Taiwan in the 1970s. The rate decreased to 8-12% in the early 1990s, and it declined to <1-3% recently. The development of new operative instruments, and surgical techniques, increased knowledge of liver anatomy and pathophysiology after hepatectomy, and more precise patient selection have contributed to this improvement. The use of intermittent hepatic inflow blood occlusion, a restrictive blood transfusion policy and intraoperative ultrasonography, have also led to substantial improvements in resectability and safety for HCC resection in Taiwan. Advances in non-operative modalities for HCC treatment have also helped to improve long-term outcomes of HCC resection. Technical innovations have allowed the application of complex procedures such as mesohepatectomy, unroofing hepatectomy, major portal vein thrombectomy, hepatic vein reconstruction in resection of the cranial part with preservation of the caudal part of the liver, and inferior vena cava and right atrium tumor thrombectomy under cardiopulmonary bypass. In selected patients, including patients with end-stage renal failure, renal graft recipients, patients with portal hypertension, hypersplenic thrombocytopenia and/or associated gastroesophageal varices, octogenarian, ruptured HCC, recurrent HCC and metastatic HCC can also be resected with satisfactory survival benefits. We conclude that the results of liver resection for HCC in Taiwan are improving. The indications for HCC resection continue extending with lower the surgical risks and increasing the long-term survival rate. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e

  19. Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: an essential investigation before resection?

    PubMed

    Leen, Edward; Ceccotti, Piercarlo; Moug, Susan J; Glen, Paul; MacQuarrie, John; Angerson, Wilson J; Albrecht, Thomas; Hohmann, Joachim; Oldenburg, Anja; Ritz, Jorg Peter; Horgan, Paul G

    2006-02-01

    The aim of the study was to assess the clinical value of contrast-enhanced intraoperative ultrasound (CE-IOUS) as a novel tool in the hepatic staging of patients undergoing liver resection. Sixty patients scheduled to undergo liver resection for metastatic disease were studied. Preoperative staging with contrast-enhanced CT and/or MR scans was performed within 2 to 6 weeks of operation. Following exploration, intraoperative ultrasound (IOUS) was performed using an HDI-5000 scanner (Philips) and a finger-probe with pulse inversion harmonic (PIH) capability. CE-IOUS in the PIH mode was performed in a standardized protocol (low MI: 0.02-0.04) after intravenous injection of 3-4 mL of SonoVue (Bracco spa, Milan); all detected lesions on precontrast and postcontrast scans were counted and mapped. Any alteration in surgical management was documented following CE-IOUS compared with IOUS. Three patients were excluded due to disseminated disease on exploration. CE-IOUS was significantly more sensitive than CT/MR and IOUS in detecting liver metastases (96.1% versus 76.7% and 81.5%, respectively) (P<0.05); it altered surgical management in 29.8% (17 of 57) of cases, due to 1) additional metastases in 19.3% (11 of 57), 2) less metastases in 3.5% (2 of 57), 3) benign lesions wrongly diagnosed as metastasis on IOUS/CT in 5.3% (3 of 57), and 4) vascular proximity in 1.8% (1 of 57). Management was unchanged in 70.2% (40 of 57) despite additional lesions detected in 3.5% (2 of 57) and benign lesion wrongly diagnosed on IOUS and CT as metastasis in 1.8% (1 of 57). CE-IOUS altered combined IOUS/CT/MR staging in 35.1%. These preliminary results suggest CE-IOUS is an essential tool prior to liver resection for metastases.

  20. Management of Portal Hypertension After Liver Transplantation.

    PubMed

    Korda, D; Deák, P Á; Kiss, G; Gerlei, Z; Kóbori, L; Görög, D; Fehérvári, I; Piros, L; Máthé, Z; Doros, A

    2017-09-01

    Post-transplantation portal hypertension has severe complications, such as esophageal varix bleeding, therapy refractory ascites, extreme splenomegaly, and graft dysfunction. The aim of our study was to analyze the effectiveness of the therapeutic strategies and how to visualize the procedure. A retrospective study involving liver transplantation patients from the Semmelweis University Department of Transplantation and Surgery was performed between 2005 and 2015. The prevalence, etiology, and leading complications of the condition were determined. The applied interventions' effects on the patients' ascites volume, splenic volume, and the occurrence of variceal bleeding were determined. Mean portal blood flow velocity and congestion index values were calculated using Doppler ultrasonography. The prevalence of post-transplantation portal hypertension requiring intervention was 2.8%. The most common etiology of the disease was portal anastomotic stenosis. The most common complications were esophageal varix bleeding and therapy refractory ascites. The patients' ascites volume decreased significantly (2923.3 ± 1893.2 mL vs. 423.3 ± 634.3 mL; P < .05), their splenic volume decreased markedly. After the interventions, only one case of recurrent variceal bleeding was reported. The calculated Doppler parameters were altered in the opposite direction in cases of pre-hepatic versus intra- or post-hepatic portal hypertension. After the interventions, these parameters shifted towards the physiologic ranges. The interventions performed in our clinic were effective in most cases. The patients' ascites volume, splenic volume, and the prevalence of variceal bleeding decreased after the treatment. Doppler ultrasonography has proved to be a valuable imaging modality in the diagnosis and the follow-up of post-transplantation portal hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Successful Removal of Malpositioned Chest Drain Within the Liver by Embolization of the Transhepatic Track

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tait, Paul; Waheed, Umeer; Bell, Suzanne, E-mail: drsuzy29@hotmail.co

    2009-07-15

    The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfullymore » removed without the complication of bleeding in a patient unsuitable for a general anesthetic.« less

  2. Liver size, bodyweight, and tolerance to acute complete occlusion of congenital extrahepatic portosystemic shunts in dogs.

    PubMed

    Doran, Ivan P; Barr, Frances J; Hotston Moore, Alasdair; Knowles, Toby G; Holt, Peter E

    2008-10-01

    To investigate the relationship between preoperative liver size, bodyweight, and tolerance to shunt occlusion in dogs with congenital extrahepatic portosystemic shunt(s) (CPSS). Longitudinal cohort study. Dogs with CPSS (n=35). Ultrasonography was used to measure preoperative maximum transverse dimension of the liver (TS) of each dog. Intraoperative portal pressures were measured, before and after CPSS occlusion, via a jejunal vein catheter. Tolerance to shunt occlusion was judged on gross visceral observations, and on changes in portal pressure, central venous and mean arterial pressures. TS was significantly related to bodyweight (P<.05). Mean ratios for TS/bodyweight were calculated for dogs tolerant and intolerant of acute complete shunt occlusion. Dogs tolerant to occlusion had significantly higher TS/bodyweight ratios than dogs intolerant to occlusion (P=.025). Dogs with a TS/bodyweight ratio of >7 were more likely to tolerate CPSS occlusion than dogs with a TS/bodyweight ratio of <5 (P=.036). A model was generated to predict portal pressure rise after shunt occlusion, based on liver dimensions and bodyweight (R=0.668). Intestinal oxygenation did not correlate significantly with tolerance to CPSS occlusion (P=.29). In dogs with CPSS, liver size (relative to bodyweight) is significantly greater (P=.025) in dogs that are tolerant of full ligation than intolerant of occlusion. Preoperative measurement of bodyweight and liver size help indicate the likelihood of tolerance to acute complete occlusion of CPSS in dogs.

  3. Forensic postmortem computed tomography: volumetric measurement of the heart and liver.

    PubMed

    Jakobsen, Lykke Schrøder; Lundemose, Sissel; Banner, Jytte; Lynnerup, Niels; Jacobsen, Christina

    2016-12-01

    The purpose of this study was to investigate the utility of postmortem computed tomography (PMCT) images in estimating organ sizes and to examine the use of the cardiothoracic ratio (CTR). We included 45 individuals (19 females), who underwent a medico-legal autopsy. Using the computer software program Mimics ® , we determined in situ heart and liver volumes derived from linear measurements (width, height and depth) on a whole body PMCT-scan, and compared the volumes with ex vivo volumes derived by CT-scan of the eviscerated heart and liver. The ex vivo volumes were also compared with the organ weights. Further, we compared the CTR with the ex vivo heart volume and a heart weight-ratio (HWR). Intra- and inter-observer analyses were performed. We found no correlation between the in situ and ex vivo volumes of the heart and liver. However, a highly significant correlation was found between the ex vivo volumes and weights of the heart and liver. No correlations between CTR and the ex vivo heart volume nor with HWR was found. Concerning cardiomegaly, we found no agreement between the CTR and HWR. The intra- and inter-observer analyses showed no significant differences. Noninvasive in situ PMCT methods for organ measuring, as performed in this study, are not useful tools in forensic pathology. The best method to estimate organ volume is a CT-scan of the eviscerated organ. PMCT-determined CTR seems to be useless for ascertaining cardiomegaly, as it neither correlated with the ex vivo heart volume nor with the HWR.

  4. Functional asplenia and portal hypertension in a patient with primary splenic hemangiosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuecel, A.E.D.; Durak, H.; Bernay, I.

    1990-05-01

    A 60-year-old man with primary splenic hemangiosarcoma (PSH) presented with weakness, weight loss, abdominal pain, and anemia. Physical examination revealed hepatomegaly, ascites, and firm, huge splenomegaly. Ultrasonography showed many nodular structures characterized by hypoechogenic and hyperechogenic areas. The patient also had portal hypertension, which was confirmed by physical findings and by measurement of portal vein pressure during operation. A liver-spleen scan using Tc-99m sulfur colloid and Tc-99m labeled heat denatured erythrocytes failed to demonstrate any splenic uptake, a reliable feature of functional asplenia. Although on a total body scan with Ga-67 citrate there was no splenic uptake, there was galliummore » uptake in the liver, where the presence of the metastatic lesion was histopathologically verified and confirmed by operation. There was also uptake in the middle zones of the lungs. Ga-67 citrate imaging appears to be helpful in the diagnosis of metastasis of PSH, and PSH can rarely cause portal hypertension.« less

  5. False-positive liver scan in a patient with hepatic amyloidosis: case report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, K.; Okuda, K.; Yoshida, T.

    1976-01-01

    A case of secondary hepatic amyloidosis exhibiting a large liver and multiple defects on the $sup 198$Au-radiocolloid scintigraph is presented. Biopsy and angiographic studies indicated that the areas of reduced colloid uptake represented heavy amyloid deposition, and the area of the left lobe with contrasting high activity most probably represented compensatory hypertrophy. (auth)

  6. Effect of ultrasound frequency on the Nakagami statistics of human liver tissues.

    PubMed

    Tsui, Po-Hsiang; Zhou, Zhuhuang; Lin, Ying-Hsiu; Hung, Chieh-Ming; Chung, Shih-Jou; Wan, Yung-Liang

    2017-01-01

    The analysis of the backscattered statistics using the Nakagami parameter is an emerging ultrasound technique for assessing hepatic steatosis and fibrosis. Previous studies indicated that the echo amplitude distribution of a normal liver follows the Rayleigh distribution (the Nakagami parameter m is close to 1). However, using different frequencies may change the backscattered statistics of normal livers. This study explored the frequency dependence of the backscattered statistics in human livers and then discussed the sources of ultrasound scattering in the liver. A total of 30 healthy participants were enrolled to undergo a standard care ultrasound examination on the liver, which is a natural model containing diffuse and coherent scatterers. The liver of each volunteer was scanned from the right intercostal view to obtain image raw data at different central frequencies ranging from 2 to 3.5 MHz. Phantoms with diffuse scatterers only were also made to perform ultrasound scanning using the same protocol for comparisons with clinical data. The Nakagami parameter-frequency correlation was evaluated using Pearson correlation analysis. The median and interquartile range of the Nakagami parameter obtained from livers was 1.00 (0.98-1.05) for 2 MHz, 0.93 (0.89-0.98) for 2.3 MHz, 0.87 (0.84-0.92) for 2.5 MHz, 0.82 (0.77-0.88) for 3.3 MHz, and 0.81 (0.76-0.88) for 3.5 MHz. The Nakagami parameter decreased with the increasing central frequency (r = -0.67, p < 0.0001). However, the effect of ultrasound frequency on the statistical distribution of the backscattered envelopes was not found in the phantom results (r = -0.147, p = 0.0727). The current results demonstrated that the backscattered statistics of normal livers is frequency-dependent. Moreover, the coherent scatterers may be the primary factor to dominate the frequency dependence of the backscattered statistics in a liver.

  7. WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leng, S; Vrieze, T; Kuhlmann, J

    2014-06-15

    Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight availablemore » printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.« less

  8. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma.

    PubMed

    Sun, Ling-Jia; Chen, Xin; Dai, Yi-Ning; Xu, Cheng-Fu; Ji, Feng; Chen, Li-Hua; Chen, Hong-Tan; Chen, Chun-Xiao

    2017-04-01

    Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (p<0.05). SMA (smooth muscle antibody) (97.2%) and desmin (94.5%) were positive in the majority of patients. In terms of treatments, patients preferred endoscopic therapies, which led to less adverse events (e.g., intraoperative bleeding, local infection, pleural effusion) than surgical operations (p<0.05). The superficial leiomyomas presented less adverse events and better recovery (p<0.05) than deep leiomyomas. Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely avoid misdiagnosis, so combining it with other

  9. Evaluation of prenatal hydronephrosis: novel criteria for predicting vesicoureteral reflux on ultrasonography.

    PubMed

    Lee, Nora G; Rushton, H Gil; Peters, Craig A; Groves, Danja S; Pohl, Hans G

    2014-09-01

    Radiographic evaluation for prenatal hydronephrosis often includes voiding cystourethrography to ascertain whether vesicoureteral reflux is present. We sought to determine whether use of voiding cystourethrography could be limited to those patients at greatest risk for vesicoureteral reflux. We hypothesized that vesicoureteral reflux could be predicted by findings on renal/bladder ultrasonography of hydroureter, renal dysmorphia and/or duplication. We reviewed the records of patients with prenatal hydronephrosis who underwent initial postnatal ultrasonography and voiding cystourethrography during a 3-year period. The presence of vesicoureteral reflux on voiding cystourethrogram was correlated to ultrasound findings, including hydronephrosis grade, presence of hydroureter, renal dysmorphia or duplication, with ultrasound considered positive for any of the latter 3 findings. Of 262 patients 47 (18%) had vesicoureteral reflux. Ultrasound was positive in 24 of 29 patients (83%) with high grade reflux and 12 of 18 (67%) with low grade reflux. If ultrasonography showed any of the 3 positive findings, the odds ratio of detecting vesicoureteral reflux was 8.07 (95% CI 3.86, 16.87). Using these criteria, among all cases of prenatal hydronephrosis 5 (2%) with high grade vesicoureteral reflux and 6 (2%) with low grade reflux would have been missed. Among the 47 cases of reflux overall 5 of 29 high grade (17%) and 6 of 18 low grade cases (33%) would have been missed. By using ultrasonography criteria of hydroureter, duplication and renal dysmorphia for patients with prenatal hydronephrosis, vesicoureteral reflux can be detected more specifically. Using our criteria, 165 of 262 voiding cystourethrograms (63%) could have been avoided in patients with prenatal hydronephrosis during a 3-year period. Reducing these evaluations may decrease risks regarding radiation exposure, family anxiety and health care costs. Copyright © 2014 American Urological Association Education and

  10. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    PubMed

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. High coffee intake is associated with lower grade nonalcoholic fatty liver disease: the role of peripheral antioxidant activity.

    PubMed

    Gutiérrez-Grobe, Ylse; Chávez-Tapia, Norberto; Sánchez-Valle, Vicente; Gavilanes-Espinar, Juan Gabriel; Ponciano-Rodríguez, Guadalupe; Uribe, Misael; Méndez-Sánchez, Nahum

    2012-01-01

    Some phytochemicals present in coffee have a potential antioxidant role which seems to protect the human body against cardiovascular diseases, liver disease and malignancies. Nonalcoholic fatty liver disease is a common disease with limited therapeutic options. This study investigated the antioxidant effect of coffee by measuring antioxidant enzymes and lipid peroxidation markers in patients with nonalcoholic fatty liver disease. We performed a case-control study at the University Hospital, Mexico City. Anthropometric, metabolic, dietary and biochemical variables of all patients were determined and compared. The presence of nonalcoholic fatty liver disease was established by ultrasonography. All patients completed a dietary questionnaire in order to determine their of coffee consumption. Catalase, superoxide dismutase and thiobarbituric acid reactive substances were measured in all of the patients. Seventy-three subjects with and 57 without nonalcoholic fatty liver disease were included. Patients with nonalcoholic fatty liver disease had significantly higher body mass index, blood glucose, homeostasis model of assessment-insulin resistance and insulin values in comparison to patients without nonalcoholic fatty liver disease. On the one hand, there was a significant difference in coffee intake between the groups (p < 0.05, for all comparisons). There was no significant difference between groups in catalase (0.39 ± 0.74 vs. 0.28 ± 0.69 nM/min/mL), superoxide dismutase (5.4 ± 3.45 vs. 4.7 ± 2.1 U/mL) or thiobarbituric acid-reactive substances (4.05 ± 1.87 vs. 3.94 ± 1.59 µM/mL). A high intake of coffee has a protective effect against nonalcoholic fatty liver disease however there was no significant difference in the antioxidant variables analyzed.

  12. Case report: liver abscess pyogenic after peritonitis appendix perforation

    NASA Astrophysics Data System (ADS)

    Damanik, E. H.; Ginting, F.

    2018-03-01

    Two of the most common liver abscess is anamoebic liver abscess and pyogenic liver abscess (PLA). PLA could be as singular or multiple abscesses. It is usually caused by Klebsiella pneumonia and Escherichia coli. Historically, PLA is usually caused by acute appendicitis, but with developed of surgical practice and microbiology, the number of events has decreased. Here we present a case of a39-year-old woman that developed a PLA after she had an appendectomy about six months ago. An ultrasonogram and abdominal scan showed an abscess in the right lobe. We performed paracentesis, and the result from the pus culturewas positive for Escherichia coli with Extended-Spectrum Beta-Lactamase (ESBL) (+) that showed the same as the culture from lesion taken from her appendix. This report emphasizes the fact that, nowadays we still found Pyogenic liver abscess after peritonitis appendix perforation.

  13. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    PubMed

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  14. International guidelines for contrast-enhanced ultrasonography: ultrasound imaging in the new millennium

    PubMed Central

    Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity. PMID:26867761

  15. Cultured mycelium Cordyceps sinensis protects liver sinusoidal endothelial cells in acute liver injured mice.

    PubMed

    Peng, Yuan; Chen, Qian; Yang, Tao; Tao, Yanyan; Lu, Xiong; Liu, Chenghai

    2014-03-01

    Cultured mycelium Cordyceps sinensis (CMCS) was widely used for a variety of diseases including liver injury, the current study aims to investigate the protective effects of CMCS on liver sinusoidal endothelial cells (LSECs) in acute injury liver and related action mechanisms. The mice were injected intraperitoneally with lipopolysaccharide (LPS) and D-galactosamine (D-GalN). 39 male BABL/c mice were randomly divided into four groups: normal control, model control, CMCS treatment and 1,10-phenanthroline treatment groups. The Serum liver function parameters including alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels were assayed with the commercial kit. The inflammation and scaffold structure in liver were stained with hematoxylin and eosin and silver staining respectively. The LSECs and sub-endothelial basement membrane were observed with the scanning and transmission electronic microscope. The protein expressions of intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) in liver were analyzed with Western blotting. Expression of von Willebrand factor (vWF) was investigated with immunofluorescence staining. The lipid peroxidation indicators including antisuperoxideanion (ASAFR), hydroxyl free radical (·OH), superoxide dismutase (SOD), malondialdehyde and glutathione S-transferase (GST) were determined with kits, and matrix metalloproteinase-2 and 9 (MMP-2/9) activities in liver were analyzed with gelatin zymography and in situ fluorescent zymography respectively. The model mice had much higher serum levels of ALT and AST than the normal mice. Compared to that in the normal control, more severe liver inflammation and hepatocyte apoptosis, worse hepatic lipid peroxidation demonstrated by the increased ASAFR, ·OH and MDA, but decreased SOD and GST, increased MMP-2/9 activities and VCAM-1, ICAM-1 and vWF expressions, which revealed obvious LSEC injury and scaffold structure broken, were shown in the model

  16. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  17. Accuracy of Physical Examination, Ultrasonography, and Mammography in Predicting Residual Pathologic Tumor Size in Patients Treated With Neoadjuvant Chemotherapy

    PubMed Central

    Chagpar, Anees B.; Middleton, Lavinia P.; Sahin, Aysegul A.; Dempsey, Peter; Buzdar, Aman U.; Mirza, Attiqa N.; Ames, Fredrick C.; Babiera, Gildy V.; Feig, Barry W.; Hunt, Kelly K.; Kuerer, Henry M.; Meric-Bernstam, Funda; Ross, Merrick I.; Singletary, S Eva

    2006-01-01

    Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. PMID:16432360

  18. Primary perivascular epithelioid cell tumour (PEComa) of the liver

    PubMed Central

    Cheung, Tan To; Trendell-Smith, Nigel; Poon, Ronnie T P

    2013-01-01

    We present a case of a 53-year-old woman with abdominal discomfort for 6 months. The liver was enlarged. Contrast CT scan of the abdomen revealed a 10 cm hypervascular tumour at the right lobe of the liver. Right hepatectomy with complete excision of the tumour was achieved. Histological and immunohistochemical findings were consistent with perivascular epithelioid cell tumour. She is regularly followed up with contrast CT assessment. There is no tumour recurrence 12 months after the operation. PMID:23845671

  19. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis.

    PubMed

    Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  20. A multidisciplinary approach for the treatment of GIST liver metastasis

    PubMed Central

    Radkani, Pejman; Ghersi, Marcelo M; Paramo, Juan C; Mesko, Thomas W

    2008-01-01

    Background Advanced gastrointestinal stromal tumors (GISTs) can metastasize and recur after a long remission period, resulting in serious morbidity, mortality, and complex management issues. Case presentation A 67-year-old woman presented with epigastric fullness, mild jaundice and weight loss with a history of a bowel resection 7 years prior for a primary GIST of the small bowel. The finding of a heterogeneous mass 15.5 cm in diameter replacing most of the left lobe of the liver by ultrasonography and CT, followed by positive cytological studies revealed a metastatic GIST. Perioperative optimization of the patient's nutritional status along with biliary drainage, and portal vein embolization were performed. Imatinib was successful in reducing the tumor size and facilitating surgical resection. Conclusion A well-planned multidisciplinary approach should be part of the standard management of advanced or metastatic GIST. PMID:18471285

  1. A Multiatlas Segmentation Using Graph Cuts with Applications to Liver Segmentation in CT Scans

    PubMed Central

    2014-01-01

    An atlas-based segmentation approach is presented that combines low-level operations, an affine probabilistic atlas, and a multiatlas-based segmentation. The proposed combination provides highly accurate segmentation due to registrations and atlas selections based on the regions of interest (ROIs) and coarse segmentations. Our approach shares the following common elements between the probabilistic atlas and multiatlas segmentation: (a) the spatial normalisation and (b) the segmentation method, which is based on minimising a discrete energy function using graph cuts. The method is evaluated for the segmentation of the liver in computed tomography (CT) images. Low-level operations define a ROI around the liver from an abdominal CT. We generate a probabilistic atlas using an affine registration based on geometry moments from manually labelled data. Next, a coarse segmentation of the liver is obtained from the probabilistic atlas with low computational effort. Then, a multiatlas segmentation approach improves the accuracy of the segmentation. Both the atlas selections and the nonrigid registrations of the multiatlas approach use a binary mask defined by coarse segmentation. We experimentally demonstrate that this approach performs better than atlas selections and nonrigid registrations in the entire ROI. The segmentation results are comparable to those obtained by human experts and to other recently published results. PMID:25276219

  2. Immunohistochemical and scanning electron microscopic comparison of the collagen network constructions between pig, goat and chicken livers.

    PubMed

    Nishimura, Shotaro; Sagara, Ayano; Oshima, Ichiro; Ono, Yoshitaka; Iwamoto, Hisao; Okano, Kaoru; Miyachi, Hideyuki; Tabata, Shoji

    2009-08-01

    The distribution and three-dimensional architecture of collagen fibers were compared between pig, goat and chicken livers. Immunohistochemical staining revealed that collagen type I was identified in the interlobular connective tissue region and intralobular areas in pigs and goats. Type III collagen was also identified in the interlobular connective tissue region and intralobular sinusoidal walls. In the chicken liver, only the circumference region of the vessels was immunostained with collagen type I and III antibodies and the interlobular connective tissue wall could not be distinguished clearly. In the intralobular region, collagen type I antibody immunoreacted around the hepatic cells but collagen type III antibody immunoreacted weakly. In the NaOH macerated specimen, well-developed collagen bundles formed the prominent interlobular walls in pigs. In contrast, the wall in the goat liver comprised a thin layer of the bundles. In the chicken liver, there were no notable collagen septa between lobules. The intralobular collagen construction was quite different between the animals, indicating a fragile collagen fibril networks in pigs, a robust framework in goats and dense fabric-like septa in chickens. These results indicate that the distinct collagen frameworks may contribute to the histological strength of the livers in each of the animal species.

  3. Intrarater reliability of measuring the patella position by ultrasonography in weight-bearing condition.

    PubMed

    Chen, Chia Lin; Lo, Chu Ling; Huang, Kai Chu; Huang, Chen Fu

    2017-10-01

    [Purpose] The aim of this study was to determine the intrarater reliability of using ultrasonography as a measurement tool to assess the patella position in a weight-bearing condition. [Subjects and Methods] Ten healthy adults participated in this study. Ultrasonography was used to assess the patella position during step down with the loading knee in flexion (0° and 20°). The distance between the patella and lateral condyle was measured to represent the patella position on the condylar groove. Two measurements were obtained on the first day and the day after 1 week by the same investigator. [Results] Excellent intrarater reliability, ranging from 0.83 to 0.93, was shown in both conditions. Standard errors of the measurements were 0.5 mm in the straight knee and 0.7 mm in the knee flexion at 20°. Minimal differences in knee flexion at 0° and knee flexion at 20° were 1.5 mm and 1.9 mm, respectively. [Conclusion] Ultrasonography is a reliable assessment tool for evaluating the positional changes of the patella in weight-bearing activities, and it can be easily used by practitioners in the clinical setting.

  4. Impact of Soft Tissue Heterogeneity on Augmented Reality for Liver Surgery.

    PubMed

    Haouchine, Nazim; Cotin, Stephane; Peterlik, Igor; Dequidt, Jeremie; Lopez, Mario Sanz; Kerrien, Erwan; Berger, Marie-Odile

    2015-05-01

    This paper presents a method for real-time augmented reality of internal liver structures during minimally invasive hepatic surgery. Vessels and tumors computed from pre-operative CT scans can be overlaid onto the laparoscopic view for surgery guidance. Compared to current methods, our method is able to locate the in-depth positions of the tumors based on partial three-dimensional liver tissue motion using a real-time biomechanical model. This model permits to properly handle the motion of internal structures even in the case of anisotropic or heterogeneous tissues, as it is the case for the liver and many anatomical structures. Experimentations conducted on phantom liver permits to measure the accuracy of the augmentation while real-time augmentation on in vivo human liver during real surgery shows the benefits of such an approach for minimally invasive surgery.

  5. Accuracy of ultrasound in the detection of liver fibrosis in chronic viral hepatitis.

    PubMed

    D'Onofrio, Mirko; Martone, Enrico; Brunelli, Silvia; Faccioli, Niccolò; Zamboni, Giulia; Zagni, Irene; Fattovich, Giovanna; Pozzi Mucelli, Roberto

    2005-10-01

    To assess the accuracy of ultrasonography (US) in the identification and grading of hepatic fibrosis in patients afflicted with chronic viral liver disease, compared to histological examination as a gold standard. We prospectively studied 105 patients (32 F, 73 M) affected by chronic viral liver disease in 36 months. Patients were studied with B-mode US and then underwent US-guided liver biopsy. All the patients were studied with conventional US with a Sequoia 512, 6.0 (Acuson, Mountain View CA, USA). We evaluated the following US parameters: liver margins, parenchymal echotexture, portal vein caliber and spleen diameter. The four B-mode US parameters were used for the US grading (from 0 to 4). Scheuer's grading (from 0 to 4) was used for the histological score. Grades 3 and 4 were considered as positive for fibrosis. Sensitivity, specificity, positive and negative predictive values and accuracy were calculated in the case of absence, positivity of one or all the US parameters. The correlation between US and histological scores was evaluated with Spearman's test. At histology seventy-seven patients (73%) had absent grade 0 (1 patient; 1%), low-moderate grade 1 (35 patients; 33%) or grade 2 (41 patients; 39%) liver fibrosis. Twenty-eight patients (27%) had severe grade 3 (16 patients; 15%) or grade 4 (12 patients; 11%) fibrosis. In the case of absence of US parameters sensitivity was 32%, specificity 32%, positive predictive value 15%, negative predictive value 57% and accuracy 32%. In the case of positivity of at least one of the US parameters the values were 68%, 68%, 43%, 84% and 69%. In the case of presence of all the US signs the results were 25%, 100%, 100%, 79% and 80%. None of the 77 patients with a healthy liver or with low-grade fibrosis was positive for all the US parameters. All the patients positive for all of the ultrasonographic parameters had high-grade fibrosis or cirrhosis at liver biopsy. Correlation between B-mode and histological scores was not

  6. Insulin resistance, body composition, and fat distribution in obese children with nonalcoholic fatty liver disease.

    PubMed

    Yang, Hye Ran; Chang, Eun Jae

    2016-01-01

    The aim of this study was to evaluate the influence of body composition, especially distribution of body fat, and insulin resistance on nonalcoholic fatty liver disease (NAFLD) in obese children. One hundred obese children (66 boys, 34 girls) with (n=60) and without NAFLD (n=40) were assessed. Anthropometry, laboratory tests, abdominal ultrasonography, and dual energy x-ray absorption metry (DXA) were evaluated in all subjects. Subject age and measurements of liver enzymes, γ- glutamyl transpeptidase (γGT), uric acid, high-density lipoprotein cholesterol, and insulin resistance were significantly different between the non-NAFLD group and NAFLD group. Body fat and trunk fat percentage were significantly different between the two groups (p<0.001 and p=0.003), whereas extremity fat percentage was not (p=0.683). Insulin resistance correlated significantly with body fat and trunk fat percentages, age, liver enzymes, γGT, and uric acid in obese children. Multiple logistic regression analysis indicated that insulin resistance and trunk fat percentage significantly affected the development of NAFLD in obese children. Body fat, especially abdominal fat, influences the development of insulin resistance and subsequent NAFLD in obese children. Therefore, body composition measurement using DXA, in conjunction with biochemical tests, may be beneficial in evaluating obese children with NAFLD.

  7. Ultrasonography and C-reactive protein can predict the outcomes of voiding cystography after the first urinary tract infection.

    PubMed

    Kido, Jun; Yoshida, Fuminori; Sakaguchi, Katsuya; Ueno, Yasushi; Yanai, Masaaki

    2015-05-01

    This study evaluated whether sex, clinical variables, laboratory variables or ultrasonography predicted the presence of vesicoureteric reflux during the first episode of urinary tract infection in paediatric patients. We also aimed to define the criteria that indicated the need for voiding cystography testing. We used voiding cystography to investigate 200 patients who experienced their first urinary tract infection at our institution between 2004 and 2013 and retrospectively analysed the data by reviewing their medical records. Sex (p = 0.001), peak blood C-reactive protein levels (p < 0.001), the duration of fever after antibiotic administration (p = 0.007) and the ultrasonography findings grade (p < 0.001) were significantly different between patients with and without vesicoureteric reflux. Grade IV-V ultrasonography findings and C-reactive protein levels of ≥80 mg/L predicted vesicoureteric reflux with a sensitivity, specificity and odds ratio of 47.8%, 87.8% and 6.59 (95% confidence interval = 3.26-13.33), respectively (p < 0.001). Voiding cystography should be performed for patients with C-reactive protein levels of ≥80 mg/L and grade IV-V ultrasonography findings, but is not necessary in patients with C-reactive protein levels of <80 mg/L and grade I-III ultrasonography findings. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  8. Endogenous Klebsiella endophthalmitis associated with liver abscess: first case report from iran.

    PubMed

    Dehghani, A R; Masjedi, A; Fazel, F; Ghanbari, H; Akhlaghi, M; Karbasi, N

    2011-01-07

    To report the first case of endogenous Klebsiella endophthalmitis associated with liver abscess in Iran. A 79-year-old man was referred to our hospital due to severe pain and visual loss in the left eye. On physical examination, conjunctival hyperemia, corneal edema, hypopyon and severe vitreous cellular reaction were identified in the left eye; however, yellowish conjunctival discoloration was more apparent in the right eye. Abdominal CT scan showed a right liver lobe abscess that was confirmed by sonographically guided percutaneous liver mass biopsy. Blood, vitreous and liver mass aspirate cultures revealed Klebsiella pneumoniae growth. The patient was thus diagnosed with endogenous Klebsiella endophthalmitis secondary to bacteremia associated with liver abscess. This report suggests that, rather than being confined to Taiwan, endogenous endophthalmitis secondary to a liver abscess due to K. pneumoniae may be a global problem. Therefore, physicians should be aware of the possibility of endophthalmitis whenever a patient with K. pneumoniae liver abscess complains of ocular symptoms.

  9. Acoustic radiation force impulse elastography, FibroScan®, Forns’ index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods

    PubMed Central

    DONG, DAO-RAN; HAO, MEI-NA; LI, CHENG; PENG, ZE; LIU, XIA; WANG, GUI-PING; MA, AN-LIN

    2015-01-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns’ index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty-one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal-Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal-Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=−0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these

  10. Comparison of contrast-enhanced ultrasonograpy with Gd-EOB-DTPA-enhanced MRI in the diagnosis of liver metastasis from colorectal cancer.

    PubMed

    Shiozawa, Kazue; Watanabe, Manabu; Ikehara, Takashi; Matsukiyo, Yasushi; Kogame, Michio; Kikuchi, Yoshinori; Otsuka, Yuichiro; Kaneko, Hironori; Igarashi, Yoshinori; Sumino, Yasukiyo

    2017-03-04

    To compare contrast-enhanced ultrasonography (CEUS) using Sonazoid with Gd-EOB-DTPA-enhanced MRI (EOB-MRI) in the diagnosis of liver metastases in patients with colorectal cancer. A total of 69 patients diagnosed with or suspected of having liver metastasis were enrolled. These hepatic lesions were diagnosed by histopathological examination after surgical resection or based on follow-up using various imaging modalities. The diagnostic accuracies of CEUS and EOB-MRI were compared. One hundred thirty-three lesions were detected. Of these lesions, 109 were diagnosed as liver metastases. Of the 133 lesions, 90.2% were detected on CEUS, and 98.5% on EOB-MRI. One hundred nine lesions were diagnosed as liver metastasis. The areas under the receiver operating characteristic curve for diagnosis were 0.906 and 0.851 on CEUS and EOB-MRI, respectively (p = 0.41). Sensitivity, specificity, positive predictive value (PPV), negative predictive value, and overall accuracy were 90.8%, 84.5%, 97.1%, 67.1%, and 90.2%, respectively, for CEUS, and 95.4%, 70.8%, 93.7%, 77.3%, and 91%, respectively, for EOB-MRI. CEUS has a higher specificity and PPV for the diagnosis of liver metastasis than EOB-MRI. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:138-144, 2017. © 2016 The Authors Journal of Clinical Ultrasound Published by Wiley Periodicals, Inc.

  11. Characterization of the biliary tract by virtual ultrasonography constructed by gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging.

    PubMed

    Koizumi, Yohei; Hirooka, Masashi; Ochi, Hironori; Tokumoto, Yoshio; Takechi, Megumi; Hiraoka, Atsushi; Ikeda, Yoshio; Kumagi, Teru; Matsuura, Bunzo; Abe, Masanori; Hiasa, Yoichi

    2015-04-01

    This study aimed at prospectively evaluating bile duct anatomy on ultrasonography and evaluating the safety and utility of radiofrequency ablation (RFA) assisted by virtual ultrasonography from gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). The institutional review board approved this study, and patients provided written informed consent prior to entry into the study. Bile duct anatomy was assessed in 201 patients who underwent Gd-EOB-DTPA-enhanced MRI for the evaluation of hepatic tumor. Eighty-one of these patients subsequently underwent RFA assisted by ultrasound imaging. In 23 patients, the tumor was located within 5 mm of the central bile duct, as demonstrated by MRI. Virtual ultrasonography constructed by Gd-EOB-enhanced MRI was able to visualize the common bile duct, left hepatic duct, and right hepatic duct in 96.5, 94.0, and 89.6 % of cases, respectively. The target hepatic tumor nodule and biliary duct could be detected with virtual ultrasonography in all patients, and no severe complications occurred. The running pattern of the bile ducts could be recognized on conventional ultrasound by referencing virtual ultrasonography constructed by Gd-EOB-DTPA-enhanced MRI. RFA assisted by this imaging strategy did not result in bile duct injury.

  12. Interpreting three-dimensional structures from two-dimensional images: a web-based interactive 3D teaching model of surgical liver anatomy

    PubMed Central

    Crossingham, Jodi L; Jenkinson, Jodie; Woolridge, Nick; Gallinger, Steven; Tait, Gordon A; Moulton, Carol-Anne E

    2009-01-01

    Background: Given the increasing number of indications for liver surgery and the growing complexity of operations, many trainees in surgical, imaging and related subspecialties require a good working knowledge of the complex intrahepatic anatomy. Computed tomography (CT), the most commonly used liver imaging modality, enhances our understanding of liver anatomy, but comprises a two-dimensional (2D) representation of a complex 3D organ. It is challenging for trainees to acquire the necessary skills for converting these 2D images into 3D mental reconstructions because learning opportunities are limited and internal hepatic anatomy is complicated, asymmetrical and variable. We have created a website that uses interactive 3D models of the liver to assist trainees in understanding the complex spatial anatomy of the liver and to help them create a 3D mental interpretation of this anatomy when viewing CT scans. Methods: Computed tomography scans were imported into DICOM imaging software (OsiriX™) to obtain 3D surface renderings of the liver and its internal structures. Using these 3D renderings as a reference, 3D models of the liver surface and the intrahepatic structures, portal veins, hepatic veins, hepatic arteries and the biliary system were created using 3D modelling software (Cinema 4D™). Results: Using current best practices for creating multimedia tools, a unique, freely available, online learning resource has been developed, entitled Visual Interactive Resource for Teaching, Understanding And Learning Liver Anatomy (VIRTUAL Liver) (http://pie.med.utoronto.ca/VLiver). This website uses interactive 3D models to provide trainees with a constructive resource for learning common liver anatomy and liver segmentation, and facilitates the development of the skills required to mentally reconstruct a 3D version of this anatomy from 2D CT scans. Discussion: Although the intended audience for VIRTUAL Liver consists of residents in various medical and surgical specialties

  13. T1-weighted dual-echo MRI for fat quantification in pediatric nonalcoholic fatty liver disease.

    PubMed

    Pacifico, Lucia; Martino, Michele Di; Catalano, Carlo; Panebianco, Valeria; Bezzi, Mario; Anania, Caterina; Chiesa, Claudio

    2011-07-07

    To determine in obese children with nonalcoholic fatty liver disease (NAFLD) the accuracy of magnetic resonance imaging (MRI) in assessing liver fat concentration. A case-control study was performed. Cases were 25 obese children with biopsy-proven NAFLD. Controls were 25 obese children matched for age and gender, without NAFLD at ultrasonography and with normal levels of aminotransferases and insulin. Hepatic fat fraction (HFF) by MRI was obtained using a modification of the Dixon method. HFF ranged from 2% to 44% [mean, 19.0% (95% CI, 15.1-27.4)] in children with NAFLD, while in the controls this value ranged from 0.08% to 4.69% [2.0% (1.3-2.5), P < 0.0001]. HFF was highly correlated with histological steatosis (r = 0.883, P < 0.0001) in the NAFLD children. According to the histological grade of steatosis, the mean HFF was 8.7% (95% CI, 6.0-11.6) for mild, 21.6% (15.3-27.0) for moderate, and 39.7% (34.4-45.0) for severe fatty liver infiltration. With a cutoff of 4.85%, HFF had a sensitivity of 95.8% for the diagnosis of histological steatosis ≥ 5%. All control children had HFF lower than 4.85%; thus, the specificity was 100%. After 12 mo, children with weight loss displayed a significant decrease in HFF. MRI is an accurate methodology for liver fat quantification in pediatric NAFLD.

  14. Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs.

    PubMed

    Sharma, Ajay; Thompson, Margret S; Scrivani, Peter V; Dykes, Nathan L; Yeager, Amy E; Freer, Sean R; Erb, Hollis N

    2011-01-01

    A cross-sectional study was performed on acutely vomiting dogs to compare the accuracy of radiography and ultrasonography for the diagnosis of small-intestinal mechanical obstruction and to describe several radiographic and ultrasonographic signs to identify their contribution to the final diagnosis. The sample population consisted of 82 adult dogs and small-intestinal obstruction by foreign body was confirmed in 27/82 (33%) dogs by surgery or necropsy. Radiography produced a definitive result (obstructed or not obstructed) in 58/82 (70%) of dogs; ultrasonography produced a definitive result in 80/82 (97%) of dogs. On radiographs, a diagnosis of obstruction was based on detection of segmental small-intestinal dilatation, plication, or detection of a foreign body. Approximately 30% (8/27) of obstructed dogs did not have radiographic signs of segmental small-intestinal dilatation, of which 50% (4/8) were due to linear foreign bodies. The ultrasonographic diagnosis of small-intestinal obstruction was based on detection of an obstructive lesion, sonographic signs of plication or segmental, small-intestinal dilatation. The ultrasonographic presence or absence of moderate-to-severe intestinal diameter enlargement (due to lumen dilatation) of the jejunum (>1.5 cm) was a useful discriminatory finding and, when present, should prompt a thorough search for a cause of small-intestinal obstruction. In conclusion, both abdominal radiography and abdominal ultrasonography are accurate for diagnosing small-intestinal obstruction in vomiting dogs and either may be used depending on availability and examiner choice. Abdominal ultrasonography had greater accuracy, fewer equivocal results and provided greater diagnostic confidence compared with radiography. © 2010 Veterinary Radiology & Ultrasound.

  15. Comparison of conventional ultrasonography and ultrasonography-computed tomography fusion imaging for target identification using digital/real hybrid phantoms: a preliminary study.

    PubMed

    Soyama, Takeshi; Sakuhara, Yusuke; Kudo, Kohsuke; Abo, Daisuke; Wang, Jeff; Ito, Yoichi M; Hasegawa, Yu; Shirato, Hiroki

    2016-07-01

    This preliminary study compared ultrasonography-computed tomography (US-CT) fusion imaging and conventional ultrasonography (US) for accuracy and time required for target identification using a combination of real phantoms and sets of digitally modified computed tomography (CT) images (digital/real hybrid phantoms). In this randomized prospective study, 27 spheres visible on B-mode US were placed at depths of 3.5, 8.5, and 13.5 cm (nine spheres each). All 27 spheres were digitally erased from the CT images, and a radiopaque sphere was digitally placed at each of the 27 locations to create 27 different sets of CT images. Twenty clinicians were instructed to identify the sphere target using US alone and fusion imaging. The accuracy of target identification of the two methods was compared using McNemar's test. The mean time required for target identification and error distances were compared using paired t tests. At all three depths, target identification was more accurate and the mean time required for target identification was significantly less with US-CT fusion imaging than with US alone, and the mean error distances were also shorter with US-CT fusion imaging. US-CT fusion imaging was superior to US alone in terms of accurate and rapid identification of target lesions.

  16. A Klebsiella pneumoniae liver abscess presenting with myasthenia and tea-colored urine: A case report and review of 77 cases of bacterial rhabdomyolysis.

    PubMed

    Deng, Lihua; Jia, Rong; Li, Wei; Xue, Qian; Liu, Jie; Miao, Yide; Wang, Jingtong

    2017-12-01

    Rhabdomyolysis is a well-known syndrome in clinical practice, although rhabdomyolysis caused by a liver abscess is rarely reported and the patient may lack symptoms that are associated with a primary site of infection. Early recognition of this possibility is needed to avoid diagnostic delay and facilitate treatment. We report the case of a 71-year-old woman with a Klebsiella pneumoniae (KP) pyogenic liver abscess who presented with myasthenia and tea-colored urine and also review the 77 reported cases of bacterial rhabdomyolysis. The patient was 71 years old and presenting with a 7-day history of myasthenia and a 3-day history of tea-colored urine, but without fever or abdominal pain. Laboratory testing in our case revealed rhabdomyolysis, and blood culture revealed KP. Abdominal ultrasonography revealed a hypoechoic enclosed mass, and computed tomography (CT) revealed an enclosed low-density mass (8.3 × 6.6 × 6.1 cm). The main diagnoses were a pyogenic liver abscess with rhabdomyolysis. Empirically intravenous piperacillin-sulbactam and intravenous potassium treatment, as well as fluid infusions and other supportive treatments were provided after admission. After the diagnosis was confirmed and susceptibility test results were available, we adjusted the antibiotics to cefoperazone and sulbactam, which were maintained for 6 weeks. The patient's symptoms relieved and the abnormal laboratory parameters corrected. Follow-up abdominal ultrasonography at 24 months after her discharge revealed that the abscess had disappeared. Early recognition and careful consideration of the underlying cause of rhabdomyolysis are critical to improving the patient's prognosis. Thus, physicians should carefully consider the underlying cause in elderly patients who present with rhabdomyolysis, as they may lack symptoms of a primary infection. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  17. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    PubMed Central

    2015-01-01

    Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents. PMID:25754367

  18. Selenomethionine Se 75 thymus scans in myasthenia gravis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toole, J.F.; Cowan, R.; Maynard, D.

    1975-01-01

    In 1966, Toole and Witcofski introduced selenomethionine Se 75 mediastinal scanning as a diagnostic test for thymomas. Since then we have performed such scans on patients with myasthenic syndrome. Because the technique is atraumatic, safe, and accurate, it can be performed on critically ill myasthenics. Two hundred and fifty microcuries of selenomethionine Se 75 is injected intravenously. Within 1 hour the mediastinum from the suprasternal notch to the ziphoid process is scanned, using a 2 x 3 inch scanner. Delayed scans have been made in a few instances but they have not increased the number of positive cases. Selenomethionine Semore » 75 is incorporated into tissues undergoing rapid protein synthesis such as thyroid, pancreas, liver, and lymphomas. Of the 34 mediastinal scans performed on myasthenics between 1966 and December 31, 1974, 4 were positive for thymoma. In addition, there was a positive scan with uptake in an area of atelectasis of the lung adjacent to the mediastinum. Of interest is the fact that 1 patient with carcinoma of the lung had a positive scan over the lesion. In 13 patients with chronic lymphatic leukemia the mediastinal scans were negative. In another patient with a mediastinal mass noted on chest x-ray, a variety of differential diagnostic possibilities were considered, such as pericardial cyst, dermoid, and aneurysm. A selenomethionine scan was strongly positive, suggesting a thymoma which subsequent surgery confirmed.« less

  19. Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study.

    PubMed

    Yang, Xiuzhen; Sun, Liying; Ye, Jingjing; Li, Xiaoying; Tao, Ran

    2017-12-01

    In this study we investigated the sonographic features of vaginal foreign bodies in girls and the diagnostic role of combined transperineal and transabdominal ultrasonography in the detection of vaginal foreign bodies in this population. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: A retrospective review of the records of 249 girls seen in the outpatient pediatric and adolescent gynecology clinic of our hospital and referred to our department for sonographic evaluation of suspected vaginal foreign bodies between 2013 and 2016 was performed. All patients were transperineally and transabdominally scanned using an ultrasound machine with 3-MHz and 7.5-MHz transducers. The sonographic features of the detected foreign bodies were recorded and reported. All patients also underwent pelvic radiography. The presence of foreign bodies was confirmed using vaginoscopy. Two hundred forty-nine patients were included in this study, and vaginal foreign bodies were detected in 181 patients. Vaginal foreign bodies often present in girls aged from 2 to 12 years old. The most common vaginal foreign bodies were toilet paper, beads, small parts of toys, cap of water color brush, and crayons. The overall sensitivity, specificity, positive and negative predictive values of transperineal/transabdominal sonography in the diagnosis of vaginal foreign bodies were 81%, 53%, 82%, and 51%, respectively. The sensitivity, specificity, and positive and negative predictive values of transabdominal sonography were 33%, 49%, 63%, and 21%, respectively. The sensitivity, specificity, and positive and negative predictive values of transperineal sonography were 64%, 49%, 77%, and 33%, respectively. Abnormal findings were detected using x-ray in only 43 of the 181 cases (23.7%). The sensitivity, specificity, and positive and negative predictive values of x-ray were 24%, 91%, 88%, and 31%, respectively. The size of the foreign bodies ranged from 2 mm to 35 mm. For foreign

  20. Pattern analysis of nerve enlargement using ultrasonography in chronic inflammatory demyelinating polyneuropathy.

    PubMed

    Jang, Jae Hong; Cho, Charles S; Yang, Kyung-Sook; Seok, Hung Youl; Kim, Byung-Jo

    2014-09-01

    Focal nerve enlargement is a characteristic finding in chronic inflammatory demyelinating polyneuropathy (CIDP). We performed this study to assess the distribution of nerve enlargement through ultrasonographic examination of peripheral nerves and to correlate the ultrasonographic findings with clinical features. To compare the ultrasonographic features of 10 subjects with CIDP with those of 18 healthy controls, we bilaterally measured the cross-sectional areas (CSA) of the vagus, brachial plexus, musculocutaneous, median, ulnar, radial, sciatic, tibial, common peroneal, and sural nerves. We also analyzed correlations between CSAs and various clinical and electrophysiological features. Mean CSAs were significantly larger in CIDP patients than controls, especially at proximal and non-entrapment sites. CSAs were significantly correlated with muscle strength at initial presentation, but not at the time of ultrasonography. The CSAs of the median and ulnar nerves at the mid-forearm, tibial nerve at 7 cm proximal to the medial malleolus, and sural nerve correlated with the nerve conduction velocity of the corresponding region. Ultrasonography revealed widely distributed nerve enlargement, especially in proximal regions and non-entrapment sites, in patients with CIDP compared with healthy controls. Nerve enlargement correlated well with the electrophysiologic function of the nerve, but not current clinical status. Pattern analysis of nerve enlargement using ultrasonography is a supportive tool in the diagnosis of CIDP. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Comparison of Ultrasonography-Guided Central Venous Catheterization Between Adult and Pediatric Populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur

    2008-05-15

    The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less

  2. Face and content validity of the virtual reality simulator 'ScanTrainer®'.

    PubMed

    Alsalamah, Amal; Campo, Rudi; Tanos, Vasilios; Grimbizis, Gregoris; Van Belle, Yves; Hood, Kerenza; Pugh, Neil; Amso, Nazar

    2017-01-01

    Ultrasonography is a first-line imaging in the investigation of women's irregular bleeding and other gynaecological pathologies, e.g. ovarian cysts and early pregnancy problems. However, teaching ultrasound, especially transvaginal scanning, remains a challenge for health professionals. New technology such as simulation may potentially facilitate and expedite the process of learning ultrasound. Simulation may prove to be realistic, very close to real patient scanning experience for the sonographer and objectively able to assist the development of basic skills such as image manipulation, hand-eye coordination and examination technique. The aim of this study was to determine the face and content validity of a virtual reality simulator (ScanTrainer®, MedaPhor plc, Cardiff, Wales, UK) as reflective of real transvaginal ultrasound (TVUS) scanning. A questionnaire with 14 simulator-related statements was distributed to a number of participants with differing levels of sonography experience in order to determine the level of agreement between the use of the simulator in training and real practice. There were 36 participants: novices ( n  = 25) and experts ( n  = 11) who rated the simulator. Median scores of face validity statements between experts and non-experts using a 10-point visual analogue scale (VAS) ratings ranged between 7.5 and 9.0 ( p  > 0.05) indicated a high level of agreement. Experts' median scores of content validity statements ranged from 8.4 to 9.0. The findings confirm that the simulator has the feel and look of real-time scanning with high face validity. Similarly, its tutorial structures and learning steps confirm the content validity.

  3. Chemical exchange saturation transfer (CEST) MR technique for in-vivo liver imaging at 3.0 tesla.

    PubMed

    Chen, Shu-Zhong; Yuan, Jing; Deng, Min; Wei, Juan; Zhou, Jinyuan; Wáng, Yì-Xiáng J

    2016-06-01

    To evaluate Chemical Exchange Saturation Transfer (CEST) MRI for liver imaging at 3.0-T. Images were acquired at offsets (n = 41, increment = 0.25 ppm) from -5 to 5 ppm using a TSE sequence with a continuous rectangular saturation pulse. Amide proton transfer-weighted (APTw) and GlycoCEST signals were quantified as the asymmetric magnetization transfer ratio (MTRasym) at 3.5 ppm and the total MTRasym integrated from 0.5 to 1.5 ppm, respectively, from the corrected Z-spectrum. Reproducibility was assessed for rats and humans. Eight rats were devoid of chow for 24 hours and scanned before and after fasting. Eleven rats were scanned before and after one-time CCl4 intoxication. For reproducibility, rat liver APTw and GlycoCEST measurements had 95 % limits of agreement of -1.49 % to 1.28 % and -0.317 % to 0.345 %. Human liver APTw and GlycoCEST measurements had 95 % limits of agreement of -0.842 % to 0.899 % and -0.344 % to 0.164 %. After 24 hours, fasting rat liver APTw and GlycoCEST signals decreased from 2.38 ± 0.86 % to 0.67 ± 1.12 % and from 0.34 ± 0.26 % to -0.18 ± 0.37 % respectively (p < 0.05). After CCl4 intoxication rat liver APTw and GlycoCEST signals decreased from 2.46 ± 0.48 % to 1.10 ± 0.77 %, and from 0.34 ± 0.23 % to -0.16 ± 0.51 % respectively (p < 0.05). CEST liver imaging at 3.0-T showed high sensitivity for fasting as well as CCl4 intoxication. • CEST MRI of in-vivo liver was demonstrated at clinical 3 T field strength. • After 24-hour fasting, rat liver APTw and GlycoCEST signals decreased significantly. • After CCl4 intoxication both rat liver APTw and GlycoCEST signals decreased significantly. • Good scan-rescan reproducibility of liver CEST MRI was shown in healthy volunteers.

  4. Isolated Deep Venous Thrombosis: Implications for 2-Point Compression Ultrasonography of the Lower Extremity.

    PubMed

    Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew

    2015-09-01

    Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  5. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    PubMed

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p < 0.05). 3-D ovarian volumes were found significantly higher in patients with PCOS (p < 0.05), and a negative correlation was also obtained between ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  6. Accurate evaluation of axillary sentinel lymph node metastasis using contrast-enhanced ultrasonography with Sonazoid in breast cancer: a preliminary clinical trial.

    PubMed

    Matsuzawa, Fumihiko; Omoto, Kiyoka; Einama, Takahiro; Abe, Hironori; Suzuki, Takashi; Hamaguchi, Jun; Kaga, Terumi; Sato, Mami; Oomura, Masako; Takata, Yumiko; Fujibe, Ayako; Takeda, Chie; Tamura, Etsuya; Taketomi, Akinobu; Kyuno, Kenichi

    2015-01-01

    Breast cancer is the most common type of cancer in women. The 5-year survival rate in patients with breast cancer ranges from 74 to 82 %. Sentinel lymph node biopsy has become an alternative to axillary lymph node dissection for nodal staging. We evaluated the detection of the sentinel lymph node and metastasis of the lymph node using contrast enhanced ultrasonography with Sonazoid. Between December 2013 and May 2014, 32 patients with operable breast cancer were enrolled in this study. We evaluated the detection of axillary sentinel lymph nodes and the evaluation of axillary lymph nodes metastasis using contrast enhanced computed tomography, color Doppler ultrasonography and contrast enhanced ultrasonography with Sonazoid. All the sentinel lymph nodes were identified, and the sentinel lymph nodes detected by contrast enhanced ultrasonography with Sonazoid corresponded with those detected by computed tomography lymphography and indigo carmine method. The detection of metastasis based on contrast enhanced computed tomography were sensitivity 20.0 %, specificity 88.2 %, PPV 60.0 %, NPV 55.6 %, accuracy 56.3 %. Based on color Doppler ultrasonography, the results were sensitivity 36.4 %, specificity 95.2 %, PPV 80.0 %, NPV 74.1 %, accuracy 75.0 %. Based on contrast enhanced ultrasonography with Sonazoid, the results were sensitivity 81.8 %, specificity 95.2 %, PPV 90.0 %, NPV 90.9 %, accuracy 90.6 %. The results suggested that contrast enhanced ultrasonography with Sonazoid was the most accurate among the evaluations of these modalities. In the future, we believe that our method would take the place of conventional sentinel lymph node biopsy for an axillary staging method.

  7. Liver Abscess Formation Following Transarterial Chemoembolization

    PubMed Central

    Lv, Wei-Fu; Lu, Dong; He, Yu-Sheng; Xiao, Jing-Kun; Zhou, Chun-Ze; Cheng, De-Lei

    2016-01-01

    Abstract To investigate the clinical features, risk factors, and bacterial spectrum of liver abscess following transarterial chemoembolization (TACE) and evaluate the therapeutic effect of percutaneous catheter drainage (PCD) on the abscesses. A retrospective review of patient charts was performed in 3613 patients who suffered from liver malignancies (2832 patients with hepatocellular carcinoma and 781 with metastatic hepatic tumor) and had undergone 11,054 TACE procedures from January 2005 to October 2013. Liver abscesses were found in 21 patients. PCD was performed in all abscess patients. The clinical features, risk factors, and bacterial spectrum of liver abscess following TACE were investigated and the therapeutic effect of PCD was evaluated. The incidence of liver abscess was 0.58% per patient and 0.19% per procedure. Approximately 57.1% of the patients had a medical history of bilioenteric anastomosis or biliary stent implantation. On computed tomography scans, the abscesses appeared as low-attenuation lesions and high-density iodinate oil scattered in the abscesses. The ultrasound showed the well defined, heterogeneously hypoechoic lesions. Positive microbiological isolates were obtained in all pus cultures and in 47.6% of blood cultures. The most common bacterium was Escherichia coli (52.4%). Twenty patients (95.2%) were cured from abscesses by using PCD, and 1 died of sepsis. Patients with predisposing factors are prone to an increased risk of liver abscess following TACE. Bacterial culture and antibiotic sensitivity tests on pus and blood help on the antibiotics selection. PCD combined with aggressive antibiotics can be recommended as the first-line therapeutic regimen. PMID:27124055

  8. Assessment of ultrasonography and computed tomography for the evaluation of unilateral orbital disease in dogs.

    PubMed

    Boroffka, Susanne A E B; Verbruggen, Anne-Marie; Grinwis, Guy C M; Voorhout, George; Barthez, Paul Y

    2007-03-01

    To describe clinical, ultrasonographic, and computed tomographic (CT) features of confirmed neoplastic and nonneoplastic disease in dogs with unilateral orbital diseases, determine criteria to differentiate between the 2 conditions, and assess the relative value of ultrasonography and CT for the differential diagnosis of these 2 conditions. Prospective study. 29 dogs with unilateral neoplastic orbital disease and 16 dogs with unilateral nonneoplastic orbital disease. Clinical history and results of physical and ophthalmologic examinations were recorded. Ultrasonographic and CT images were evaluated, and discriminating factors were identified to differentiate neoplastic from nonneoplastic diseases. Diagnostic value of ultrasonography and CT was assessed. Dogs with neoplastic disease were significantly older; had clinical signs for a longer time before initial examination; had more progressive onset of clinical signs; and more frequently had protrusion of the nictitating membrane, fever, and anorexia. The most discriminating factor for both imaging modalities was delineation of the margins (odds ratio was 41.7 for ultrasonography and 45 for CT), with neoplastic lesions clearly delineated more often. Ultrasonographically, neoplastic lesions were more frequently hypoechoic and homogeneous, with indentation of the globe and bone involvement evident more frequently than for nonneoplastic lesions. Mineralization was detected only with neoplasia. Fluctuant fluid was seen more frequently in dogs with nonneoplastic disease. Computed tomography more frequently revealed extraorbital involvement. Diagnostic value was similar for both imaging modalities. Ultrasonography and CT are valuable imaging modalities to assist in differentiating neoplastic from nonneoplastic unilateral orbital disease in dogs.

  9. Practical application of color Doppler ultrasonography in patients with ejaculatory dysfunction.

    PubMed

    Hara, Ryoei; Nagai, Atsushi; Fujii, Tomohiro; Fukumoto, Kazuhiko; Ohira, Shin; Jo, Yoshimasa; Yokoyama, Teruhiko; Miyaji, Yoshiyuki

    2015-06-01

    We describe two cases in which dynamic analysis of ejaculation using color Doppler ultrasonography was useful in diagnosis of ejaculatory dysfunction and planning of therapy. The first patient was a 32-year-old man with a diagnosis of retrograde ejaculation. A bladder neck collagen injection was carried out, as the main cause was thought to be the bladder neck remaining open during ejaculation. The patient had antegrade ejaculation 1 week later. The second patient was a 48-year-old man with a diagnosis of anorgasmia accompanied by decreased seminal emission and insufficient function of the rhythmic pelvic striated muscles. The patient was prescribed etilefrine hydrochloride 15 mg/day. The symptom improved 2 weeks after starting this drug. These cases suggest that the use of color Doppler ultrasonography during ejaculation can improve the understanding of ejaculatory dysfunction and therapy for this condition. © 2015 The Japanese Urological Association.

  10. Feasibility of Respiratory Triggering for MR-Guided Microwave Ablation of Liver Tumors Under General Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morikawa, Shigehiro, E-mail: morikawa@belle.shiga-med.ac.jp; Inubushi, Toshiro; Kurumi, Yoshimasa

    2004-08-15

    We obtained clear and reproducible MR fluoroscopic images and temperature maps for MR image-guided microwave ablation of liver tumors under general anesthesia without suspending the artificial ventilation. Respiratory information was directly obtained from air-way pressure without a sensor on the chest wall. The trigger signal started scanning of one whole image with a spoiled gradient echo sequence. The delay time before the start of scanning was adjusted to acquire the data corresponding to the k-space center at the maximal expiratory phase. The triggered images were apparently clearer than the nontriggered ones and the location of the liver was consistent, whichmore » made targeting of the tumor easy. MR temperature images, which were highly susceptible to the movement of the liver, during microwave ablation using a proton resonance frequency method, could be obtained without suspending the artificial ventilation. Respiratory triggering technique was found to be useful for MR fluoroscopic images and MR temperature monitoring in MR-guided microwave ablation of liver tumors under general anesthesia.« less

  11. FT3/FT4 ratio predicts non-alcoholic fatty liver disease independent of metabolic parameters in patients with euthyroidism and hypothyroidism

    PubMed Central

    Gökmen, Fatma Yahyaoğlu; Ahbab, Süleyman; Ataoğlu, Hayriye Esra; Türker, Betül Çavuşoğlu; Çetin, Faik; Türker, Fatih; Mamaç, Rabia Yahyaoğlu; Yenigün, Mustafa

    2016-01-01

    OBJECTIVE: This study was performed to evaluate the effects of metabolic parameters and thyroid dysfunction on the development of non-alcoholic fatty liver disease (NAFLD). METHODS: The current study evaluated a total of 115 patients, 75 female and 40 male. Physical examination and anthropometric measurements were applied to all participants. Hypothyroidism was considered at a thyroid stimulating hormone level ≥ 4.1 mIU/L. Patients with euthyroidism and patients with hypothyroidism were compared. Abdominal ultrasonography was used to diagnose non-alcoholic fatty liver disease. The participants were further compared with regard to the presence of non-alcoholic fatty liver disease. Logistic regression modeling was performed to identify the relationship between non-alcoholic fatty liver disease and independent variables, such as metabolic parameters and insulin resistance. RESULTS: Non-alcoholic fatty liver disease was identified in 69 patients. The mean waist circumference, body mass index, fasting plasma insulin, HOMA-IR (p<0.001) and FT3/FT4 ratio (p=0.01) values were significantly higher in the patients with NAFLD compared to those without it. Multivariate regression analysis revealed that FT3/FT4 ratio, waist circumference and insulin resistance were independent risk factors for non-alcoholic fatty liver disease. CONCLUSION: Insulin resistance, enlarged waist circumference, elevated body mass index, higher FT3/FT4 ratio and hypertriglyceridemia are independent risk factors for NADLF, whereas hypothyroidism is not directly related to the condition. PMID:27166773

  12. Lung Ultrasonography: A Viable Alternative to Chest Radiography in Children with Suspected Pneumonia?

    PubMed

    Ambroggio, Lilliam; Sucharew, Heidi; Rattan, Mantosh S; O'Hara, Sara M; Babcock, Diane S; Clohessy, Caitlin; Steinhoff, Mark C; Macaluso, Maurizio; Shah, Samir S; Coley, Brian D

    2016-09-01

    To determine the interrater reliability (IRR) of lung ultrasonography (LUS) and chest radiography (CXR) and evaluate the accuracy of LUS compared with CXR for detecting pediatric pneumonia compared with chest computed tomography (CT) scan. This was a prospective cohort study of children aged 3 months to 18 years with a CXR and LUS performed between May 1, 2012, and January 31, 2014 with or without a clinical diagnosis of pneumonia. Four pediatric radiologists blinded to clinical information reported findings for the CXR and LUS images. IRR was estimated for 50 LUS and CXR images. The main outcome was the finding from CT ordered clinically or the probability of the CT finding for patients clinically requiring CT. Two radiologists reviewed CT scans to determine an overall finding. Latent class analysis was used to evaluate the sensitivity and specificity for findings (eg, consolidation) for LUS and CXR compared with CT. Of the 132 patients in the cohort, 36 (27%) had CT performed for a clinical reason. Pneumonia was clinically documented in 47 patients (36%). The IRR for lung consolidation was 0.55 (95% CI, 0.40-0.70) for LUS and 0.36 (95% CI, 0.21-0.51) for CXR. The sensitivity for detecting consolidation, interstitial disease, and pleural effusion was statistically similar for LUS and CXR compared with CT; however, specificity was higher for CXR. The negative predictive value was similar for CXR and LUS. LUS has a sufficiently high IRR for detection of consolidation. Compared with CT, LUS and CXR have similar sensitivity, but CXR is more specific for findings indicating pneumonia. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. 3-Dimensional liver volume assessment in patients with hepatitis B virus-related liver cirrhosis during long-term oral nucleos(t)ide analogues therapy.

    PubMed

    Lee, Chang Hun; Kim, In Hee; Moon, Jin Chang; Seo, Seung Young; Kim, Seong Hun; Kim, Sang Wook; Lee, Seung Ok; Lee, Soo Teik; Kim, Dae Ghon; Yang, Jae Do; Yu, Hee Chul

    2017-01-14

    To assess the effect of long-term oral nucleos(t)ide analogues (NUCs) therapy on liver volume change in patients with suppress hepatitis B virus (HBV)-related liver cirrhosis. We reviewed the data of naïve patients with HBV-related liver cirrhosis, who had taken oral NUCs therapy, between 2003 and 2007 at Chonbuk University Hospital. We analyzed two consecutive sets of abdominal computerized tomography scans-one at the time of treatment initiation and another at the second-year follow-up. Liver volume was calculated by 3-dimensional liver extraction volumetry program. A total of 55 patients (34 males) were included. There was 114.3 mL ± 167.8 mL (12.9% ± 17.9%) of increase in liver volume during the two years of NUCs therapy (993.8 mL ± 242.8 mL at baseline vs 1108.1 mL ± 263.3 mL at two-year follow-up, P < 0.001). The ratio of the measured baseline liver volume to the estimated standard liver volume was improved from 70.8% to 78.0%. An increase in liver volume was shown not only in patients with compensated cirrhosis ( P = 0.046) but also in those with decompensated cirrhosis ( P < 0.001). Significant factors for volume increases were Child-Turcotte-Pugh grade and model for end-stage liver disease score improvement without virological breakthrough. In multiple linear regression analysis, delta albumin and delta alanine aminotransferase levels showed a significant association with the increase in liver volume ( P = 0.002 and 0.005, respectively). Long-term oral NUCs therapy in patients with HBV-related liver cirrhosis lead to significant increase in liver volume assessed with 3-dimensional liver extraction volumetry program.

  14. Enteral nutrition tube placement assisted by ultrasonography in patients with severe acute pancreatitis

    PubMed Central

    Li, Gang; Pan, Yiyuan; Zhou, Jing; Tong, Zhihui; Ke, Lu; Li, Weiqin

    2017-01-01

    Abstract To evaluate the effect of a novel procedure using real-time ultrasonography to assist nasojejunal tube placement at bedside in patients with severe acute pancreatitis (SAP). Single center, prospective descriptive study in a 15-bed surgery intensive care unit of a university hospital. Thirty SAP patients were enrolled. The whole procedure of placing nasojejunal tube was performed by a single physician, who places nasojejunal tube at the bedside and performs ultrasonography to guide the tube positioning. The final nasojejunal tube position was confirmed by abdominal radiograph. The successful rate of the procedure as well as the time it took, the time from the decision of enteral feeding to commencement of feeding, and complications were recorded. Thirty-six intubations were performed in 30 patients by using ultrasonography-assisted method at bedside. Nasojejunal tubes were successful placed in 28 of 30 patients (93.3%). The average time of successful placement was 22.07 ± 5.78 minutes. The median time between physician's decision for tube placement and feeding initiation was 5.5 (2, 24) hours. No adverse events occurred in all of patients. This novel method of nasojejunal tube placement under ultrasound guidance is practical, less time consuming and reliable. PMID:29137035

  15. Limitations of ultrasonography for diagnosing white matter damage in preterm infants.

    PubMed

    Debillon, T; N'Guyen, S; Muet, A; Quere, M P; Moussaly, F; Roze, J C

    2003-07-01

    To compare the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) in diagnosing white matter abnormalities in preterm infants and to determine the specific indications for MRI. Prospective cohort study. A neonatal intensive care unit in France. All preterm infants (scan, the results of which were taken as the final diagnosis. Statistical analysis was performed to determine which early imaging study best predicted the term MRI findings. The early US and MRI findings (79 infants) correlated closely for severe lesions (cystic periventricular leucomalacia and parenchymal infarction; kappa coefficient = 0.86) but not for moderate lesions (non-cystic leucomalacia and parenchymal punctate haemorrhages; kappa = 0.62). Overall, early MRI findings predicted late MRI findings in 98% of patients (95% confidence interval (CI) 89.5 to 99.9) compared with only 68% for early US (95% CI 52.1 to 79.2). US is highly effective in detecting severe lesions of the white matter in preterm infants, but MRI seems to be necessary for the diagnosis of less severe damage. MRI performed at about the third week of life is highly predictive of the final diagnosis at term.

  16. High-frequency ultrasound for monitoring changes in liver tissue during preservation

    NASA Astrophysics Data System (ADS)

    Vlad, Roxana M.; Czarnota, Gregory J.; Giles, Anoja; Sherar, Michael D.; Hunt, John W.; Kolios, Michael C.

    2005-01-01

    Currently the only method to assess liver preservation injury is based on liver appearance and donor medical history. Previous work has shown that high-frequency ultrasound could detect ischemic cell death due to changes in cell morphology. In this study, we use high-frequency ultrasound integrated backscatter to assess liver damage in experimental models of liver ischemia. Ultimately, our goal is to predict organ suitability for transplantation using high-frequency imaging and spectral analysis techniques. To examine the effects of liver ischemia at different temperatures, livers from Wistar rats were surgically excised, immersed in phosphate buffer saline and stored at 4 and 20 °C for 24 h. To mimic organ preservation, livers were excised, flushed with University of Wisconsin (UW) solution and stored at 4 °C for 24 h. Preservation injury was simulated by either not flushing livers with UW solution or, before scanning, allowing livers to reach room temperature. Ultrasound images and corresponding radiofrequency data were collected over the ischemic period. No significant increase in integrated backscatter (~2.5 dBr) was measured for the livers prepared using standard preservation conditions. For all other ischemia models, the integrated backscatter increased by 4-9 dBr demonstrating kinetics dependent on storage conditions. The results provide a possible framework for using high-frequency imaging to non-invasively assess liver preservation injury.

  17. Postoperative liver volume was accurately predicted by a medical image three dimensional visualization system in hepatectomy for liver cancer.

    PubMed

    Cai, Wei; Fan, Yingfang; Hu, Haoyu; Xiang, Nan; Fang, Chihua; Jia, Fucang

    2017-06-01

    Liver cancer is the second most common cause of cancer death worldwide. The hepatectomy is the most effective and the only potentially curative treatment for patients with resectable neoplasm. Precisely preoperative assessment of remnant liver volume is essential in preventing postoperative liver failure. The aim of our study is to report our experience of using a medical image three dimensional (3D) visualization system (MI-3DVS), which was developed by our team, in assisting hepatectomy for patients with liver cancer. Between January 2010 and June 2016, 69 patients with liver cancer underwent hepatic resection based on the MI-3DVS were enrolled in this study. All patients underwent CT scan 5 days before the surgery and within 5 days after resection. CT images were reconstructed with the MI-3DVS to assist to perform hepatectomy. Simple linear regression, intra-class correlation coefficient (ICC) and Bland-Altman analysis were used to evaluate the relationship and agreement between actual excisional liver volume (AELV) and predicted excisional liver volume (PELV). Among 69 patients in this study, 62(89.85%) of them were diagnosed with hepatocellular carcinoma by histopathologic examination, and 41(59.42%) underwent major hepatectomy. The average AELV was 330.13 cm 3 and the average PELV was 287.67 cm 3 . The simple regression equation is AELV = 1.016 × PELV+30.39(r = 0.966; p < 0.0003). PELV (ICC = 0.964) achieved an excellent agreement with AELV with statistical significance (p < 0.001). 65 of 69 dots are in the range of 95% confidence interval in Bland-Altman analyses. The MI-3DVS has advantages of simple usage and convenient hold. It is accurate in assessment of postoperative liver volume and improve safety in liver resection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Two-dimensional ultrasonography of the brain: its diagnostic usefullness in herpes simplex encephalitis and cytomegalic inclusion disease.

    PubMed

    Matsumoto, N; Yano, S; Miyao, M; Kamoshita, S; Itoh, K

    1983-01-01

    We have used brain ultrasonography in diagnosing and following up two infants, one with herpes simplex encephalitis and the other with cytomegalic inclusion disease. It was found that this technique was very useful to observe the changes of the brain parenchyma such as cystic degeneration and periventricular calcification. Also because it is non-invasive and an easy procedure, ultrasonography can be applied even for infants in critical condition when needed.

  19. Use of ultrasonography to diagnose large colon volvulus in horses.

    PubMed

    Abutarbush, Sameeh M

    2006-02-01

    To describe the use of ultrasonography to diagnose large colon volvulus (LCV) in horses. Descriptive report. 4 horses with clinical signs of abdominal pain. Each horse was administered analgesic agents for pain control and placed in stocks. Ultrasonographic evaluations were performed with a 3.5-MHz sector scanning transducer that was placed parallel to the long axis of the horse (longitudinal imaging) over an area of the left ventral aspect of the abdomen. The boundaries of the evaluated region included the ventral midline, 2 vertical lines at the level of the left 10th and 17th intercostal spaces, and a horizontal line between the 2 vertical lines at the level of the costal arch of the left 10th intercostal area. In all horses, nonsacculated large colon was identified ultrasonographically in the left ventral portion of the abdomen; this finding was considered indicative of LCV. In 3 horses, the LCV involved intestinal rotation of 180 degrees, whereas in 1 horse, the LCV involved intestinal rotation of 540 degrees. As confirmed by surgical or postmortem findings, the degree and location of the volvulus were correctly estimated from ultrasonographic images. In horses, this method of diagnosis of LCV appears to be of value regardless of the location at which the rotation of the large colon occurs. Ultrasonographic findings may aid in the earlier diagnosis of LCV in horses, especially at an early stage of the disease when other clinical signs are equivocal.

  20. Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis.

    PubMed

    Rahimi-Movaghar, Vafa; Yousefifard, Mahmoud; Ghelichkhani, Parisa; Baikpour, Masoud; Tafakhori, Abbas; Asady, Hadi; Faridaalaee, Gholamreza; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2= 68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2= 88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2= 92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2= 99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer.

  1. Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis

    PubMed Central

    Rahimi-Movaghar, Vafa; Yousefifard, Mahmoud; Ghelichkhani, Parisa; Baikpour, Masoud; Tafakhori, Abbas; Asady, Hadi; Faridaalaee, Gholamreza; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    Introduction: Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Methods: Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Results: Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2= 68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2= 88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2= 92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2= 99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. Conclusion: The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer

  2. Significance of Portal Venous Velocity in Short-term Graft Function in Living Donor Liver Transplantation.

    PubMed

    Wakiyama, S; Takano, Y; Shiba, H; Gocho, T; Sakamoto, T; Ishida, Y; Yanaga, K

    2017-06-01

    Graft regeneration and functional recovery after reperfusion of transplanted graft are very important for successful living donor liver transplantation (LDLT). The aim of this study was to evaluate the significance of postoperative portal venous velocity (PVV) in short-term recovery of graft function in LDLT. From February 2007 through December 2015, we performed 17 primary LDLTs, which were included in the present study. The patients ranged in age from 12 to 65 years (mean: 50 years), and 11 were female patients. Postoperatively, Doppler ultrasonography was performed daily to measure PVV (cm/s), and liver function parameters were measured daily. The change in PVV (ΔPVV) was defined as follows: ΔPVV = PVV on postoperative day (POD) 1 - PVV on POD 7. Maximal value of serum aspartate aminotransferase (ASTmax) and maximal value of serum alanine transaminase (ALTmax) at 24 hours after graft reperfusion were used as parameters of reperfusion injury. Correlation analyses were performed as follows: (1) correlation of ΔPVV and PVV on POD 1 (PVV-POD 1) with the values such as ASTmax, ALTmax, other liver function parameters on POD 7 and graft regeneration rate; (2) correlation of ASTmax and ALTmax with other liver function parameters on POD 7. ΔPVV significantly correlated with the values of serum total bilirubin (P < .01), prothrombin time (P < .01), and platelet count (P < .05), and PVV-POD 1 significantly correlated with the values of serum total bilirubin (P < .05) and prothrombin time (P < .05). ΔPVV and PVV-POD 1 may be useful parameters of short-term functional recovery of the transplant liver in LDLT. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Triglycerides to high-density lipoprotein cholesterol ratio is an independent predictor of incident fatty liver; a population-based cohort study.

    PubMed

    Fukuda, Yukiko; Hashimoto, Yoshitaka; Hamaguchi, Masahide; Fukuda, Takuya; Nakamura, Naoto; Ohbora, Akihiro; Kato, Takahiro; Kojima, Takao; Fukui, Michiaki

    2016-05-01

    Triglycerides (TG) to high-density lipoprotein cholesterol (HDL-C) ratio (TG/HDL-C) has been recommended for surrogates of insulin resistance. However, it remains to be elucidated the association between TG/HDL-C and incident fatty liver. To investigate the association between TG/HDL-C and incident fatty liver. We performed population-based historical cohort study consisted with 4518 healthy Japanese who received yearly health-checkup programmes over decade. Fatty liver was diagnosed using ultrasonography. During the observation periods, 38.8% (case/N = 1023/2637) of men and 17.2% (case/N = 324/1881) of women developed fatty liver. Adjusting odds ratio of TG/HDL-C for incident fatty liver were 1.59 (95% confidence interval (CI) 1.42-1.79, P < 0.0001) in men and 2.50 (95% CI 1.80-3.51, P < 0.0001) in women. In addition, adjusting odds ratio of TG/HDL-C for incident non-alcoholic fatty liver disease were 1.55 (95% CI 1.35-1.77, P < 0.0001) in men and 2.72 (95% CI 1.88-3.95, P < 0.0001) in women. According to the receiver operator characteristic (ROC) analysis, the optimal cut-off point of TG/HDL-C for incident fatty liver was 0.88 (area under the ROC curve (AUC) 0.67 [95% CI 0.65-0.69], sensitivity = 0.64, specificity = 0.60, P < 0.0001) in men and 0.64 (AUC 0.69 [95% CI 0.66-0.72], sensitivity = 0.50, specificity = 0.78, P < 0.0001) in women. The TG/HDL-C could predict the incident fatty liver. Thus, it is important to check TG/HDL-C and lifestyles modification is needed for preventing future fatty liver disease in patients with high TG/HDL-C. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Assessment of the fatty liver index as an indicator of hepatic steatosis for predicting incident diabetes independently of insulin resistance in a Korean population.

    PubMed

    Jung, C H; Lee, W J; Hwang, J Y; Yu, J H; Shin, M S; Lee, M J; Jang, J E; Leem, J; Park, J-Y; Kim, H-K

    2013-04-01

    Fatty liver disease, especially non-alcoholic fatty liver disease, is considered to be the hepatic manifestation of the metabolic syndrome, both closely associated with insulin resistance. Furthermore, fatty liver disease assessed by ultrasonography is known to be a predictor of the development of Type 2 diabetes mellitus. However, it remains unclear whether fatty liver disease plays a role in the pathogenesis of Type 2 diabetes independently of insulin resistance. In this study, we investigated whether fatty liver disease assessed by the fatty liver index can predict the development of Type 2 diabetes independently of systemic insulin resistance. We examined the clinical and laboratory data of 7860 subjects without diabetes who underwent general routine health evaluations at the Asan Medical Center in 2007 and had returned for follow-up examinations in 2011. Fatty liver index was calculated using an equation that considers serum triglyceride levels, γ-glutamyltransferase, waist circumference and BMI. During a 4-year period, 457 incident diabetes cases (5.8%) were identified. The odds ratios for the development of Type 2 diabetes were significantly higher in the group with a fatty liver index ≥ 60 (fatty liver index-positive) than in the group with a fatty liver index < 20 (fatty liver index-negative) after adjusting for various confounding variables including homeostasis model assessment of insulin resistance. Odds ratios were significant regardless of the insulin resistance status at baseline. Our results suggest that fatty liver index as a simple surrogate indicator of hepatic steatosis is valuable in identifying subjects at high risk for Type 2 diabetes. In addition, fatty liver disease itself contributes to the development of Type 2 diabetes independently of systemic insulin resistance. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  5. Testicular volume measurement: comparison of ultrasonography, orchidometry, and water displacement.

    PubMed

    Sakamoto, Hideo; Saito, Katsuyuki; Oohta, Michiya; Inoue, Katuki; Ogawa, Yoshio; Yoshida, Hideki

    2007-01-01

    To determine the accuracy of orchidometry and ultrasonography for measuring the testicular volume by comparing the resultant measurements with the actual testicular volume in humans. The testicular volume of 40 testes from 20 patients with prostate cancer (mean age +/- SD 74.5 +/- 7.5 years) was measured using the Prader orchidometer and ultrasonography before therapeutic bilateral orchiectomy. The ultrasound measurements of testicular volume were calculated using three formulas: length (L) x width (W) x height (H) x 0.52, L x W2 x 0.52, and L x W x H x 0.71. The actual testicular volumes were determined by water displacement of the surgical specimen. The mean actual testicular volume of the 40 testes was 9.3 cm3 (range 2.5 to 23.0). A strong correlation was found between the testicular volume calculated by the three ultrasound formulas and the actual volume (r = 0.910 to 0.965, P <0.0001) and was stronger than the correlation with the Prader orchidometer (r = 0.818, P <0.0001). The smallest mean difference from the actual testicular volume was observed with the formula L x W x H x 0.71, which overestimated the actual volume by 0.80 cm3 (7.42%). The measurements using the Prader orchidometer correlated with the actual testicular volume and with the testicular volume calculated using the three ultrasound formulas (r = 0.801 to 0.816, P <0.0001). However, the orchidometer measurements had the largest mean difference from the actual testicular volume (6.68 cm3, 81.7%). The results of this study have shown that measuring the testicular volume by ultrasonography is more accurate than by the Prader orchidometer, and the formula L x W x H x 0.71 was the most accurate for calculating the testicular volume.

  6. Intra-abdominal fat measurement by ultrasonography: association with anthropometry and metabolic syndrome in adolescents.

    PubMed

    Novais, Rommel L R; Café, Ana Carolina C; Morais, Aisha A; Bila, Wendell C; Santos, Gilson D da S; Lopes, Carlos Alexandre de O; Belo, Vinícius S; Romano, Márcia Christina C; Lamounier, Joel A

    2018-04-27

    To associate intra-abdominal fat thickness measured by ultrasonography to the factors related to metabolic syndrome and to determine cutoff points of intra-abdominal fat measurement associated with a greater chance of metabolic syndrome in adolescents. This was a cross-sectional study, with 423 adolescents from public schools. Intra-abdominal fat was measured by ultrasonography. Anthropometric data were collected, and biochemical analyses were performed. Intra-abdominal fat was measured by ultrasonography, showing a statistically significant association with the diagnosis of metabolic syndrome (p=0.037), body mass index (p<0.001), elevated triglyceride levels (p=0.012), decreased plasma HDL levels (p=0.034), and increased systemic blood pressure values (p=0.023). Cutoff values of intra-abdominal fat thickness measurements were calculated by ultrasound to estimate the individuals most likely to develop metabolic syndrome. In the logistic regression models, the cutoff values that showed the highest association with metabolic syndrome in males were 4.50, 5.35, 5.46, 6.24, and 6.50cm for the ages of 14, 15, 16, 17, and 18/19 years, respectively. In the female gender, the cutoff values defined for the same age groups were 4.46, 4.55, 4.45, 4.90, and 6.46cm. In an overall analysis using the ROC curve, without gender and age stratification, the cut-off of 3.67cm showed good sensitivity, but low specificity. Ultrasonography is a useful method to estimate intra-abdominal adipose tissue in adolescents, which is associated with the main factors related to obesity and metabolic syndrome. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  7. Validation of equations for pleural effusion volume estimation by ultrasonography.

    PubMed

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  8. A case of gas-forming liver abscess with diabetes mellitus.

    PubMed

    Tatsuta, Tetsuya; Wada, Toyohito; Chinda, Daisuke; Tsushima, Kiyoto; Sasaki, Yoshio; Shimoyama, Tadashi; Fukuda, Shinsaku

    2011-01-01

    A 43-year-old man was admitted to our hospital with right hypochondriac and epigastric pain. An abdominal radiograph showed a large niveau in the right subphrenic space. An abdominal CT scan demonstrated a large liver abscess (diameter, 13 cm) with gas formation. Klebsiella pneumoniae cells were isolated from the abscess, and the patient was treated with antibiotics and percutaneous drainage. It is very important to treat gas-forming liver abscess immediately, because subsequent bacteremia and septic shock are frequently noted, and the associated mortality rate is high.

  9. The role of transvaginal ultrasonography for detecting ovarian cancer in an asymptomatic screening population: a systematic review.

    PubMed

    Buhling, Kai J; Lezon, S; Eulenburg, C; Schmalfeldt, B

    2017-05-01

    The purpose of this study was to systematically analyze the effect of transvaginal ultrasonography in an asymptomatic female population as an annual screening procedure with regard to mortality data. Studies were evaluated descriptively on their strengths and weaknesses considering the methods and results. We evaluated 632 international studies by selecting only randomized controlled trials (RCTs). Three RCTs concerning transvaginal ultrasonography were found, performed in Japan, the USA, and Great Britain. Currently, no clear recommendation for the screening for ovarian cancer in an asymptomatic population can be given based on these three studies. The authors could not show a change in mortality using transvaginal ultrasonography for annual screening. An annual palpation does not offer a beneficial effect. The development of new ultrasound machines with higher image resolution in combination with a well-standardized algorithm for ovarian cancer in upcoming years might provide an improvement regarding mortality. The current studies do not show a benefit in screening an asymptomatic population annually with transvaginal ultrasonography, but the most recent publication showed a trend toward lower mortality in patients who underwent screening after 7-14 years of follow-up. Nevertheless, all three heterogeneous RCTs had weaknesses in their methods and therefore they neither contradict the general recommendation for screening in an asymptomatic population nor do they support it.

  10. Ultrasonography of adnexal causes of acute pelvic pain in pre-menopausal non-pregnant women

    PubMed Central

    Dupuis, Carolyn S.; Kim, Young H.

    2015-01-01

    Acute-onset pelvic pain is an extremely common symptom in premenopausal women presenting to the emergency department. After excluding pregnancy in reproductive-age women, ultrasonography plays a major role in the prompt and accurate diagnosis of adnexal causes of acute pelvic pain, such as hemorrhagic ovarian cysts, endometriosis, ovarian torsion, and tubo-ovarian abscess. Its availability, relatively low cost, and lack of ionizing radiation make ultrasonography an ideal imaging modality in women of reproductive age. The primary goal of imaging in these patients is to distinguish between adnexal causes of acute pelvic pain that may be managed conservatively or medically, and those requiring emergency/urgent surgical or percutaneous intervention. PMID:26062637

  11. Acoustic radiation force impulse elastography, FibroScan®, Forns' index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods.

    PubMed

    Dong, Dao-Ran; Hao, Mei-Na; Li, Cheng; Peng, Ze; Liu, Xia; Wang, Gui-Ping; Ma, An-Lin

    2015-06-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns' index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty‑one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal‑Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal‑Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=‑0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of

  12. Fecal retention in childhood: Evaluation on ultrasonography.

    PubMed

    Hatori, Reiko; Tomomasa, Takeshi; Ishige, Takashi; Tatsuki, Maiko; Arakawa, Hirokazu

    2017-04-01

    To assess the usefulness of rectal diameter measurement on ultrasonography as a diagnostic tool for fecal retention in children. One hundred children (median age, 5.0 years), consisting of 80 with functional constipation and 20 without constipation, participated in the study. All patients underwent physical examination that included digital rectal examination. Forty-five children underwent ultrasonography in three differential planes: transection above the symphysis; under the ischial spine; and at the bladder neck. The measurement of the rectal diameter at the transection above the symphysis could most easily detect fecal retention and had the closest correlations with retention among the three planes. Rectal diameter was wider at all measuring points (35.2 vs 20.9 mm above the symphysis, P < 0.0001; 35.7 vs 24.0 mm under the ischial spine, P < 0.0001; and 19.4 vs 8.7 mm at the bladder neck, P < 0.0001) in children with fecal retention than in those with no fecal retention. With regard to presence of constipation, children with fecal retention had a wider rectal diameter above the symphysis than those with no fecal retention (children with functional constipation, 35.3 vs 20.0 mm, P < 0.0001; children without constipation: 32.6 vs 14.6 mm, P = 0.0026). The cut-off for the rectal diameter measured above the symphysis to identify fecal retention was 27 mm, with high sensitivity and specificity (95.5% and 94.1%, respectively). Ultrasound rectal diameter measurement can be used to detect fecal retention in children. © 2016 Japan Pediatric Society.

  13. WE-EF-303-02: BEST IN PHYSICS (JOINT IMAGING- THERAPY): A Comprehensive Simulation of Image Guided Beam Gating for Liver Tumor Treatments Using Scanned Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Y; Knopf, A; Weber, D

    2015-06-15

    Purpose: To evaluate the effectiveness of image guided beam gating for PBS liver treatments under realistic breathing conditions. Methods: We have previously proposed a Beams’ Eye View (BEV) X-ray image system as an online motion monitoring device for deriving a gating signal for PBS proton therapy. Using dedicated 4D dose calculations (4DDC), in this work we have simulated gated liver treatments using three amplitude-based gating windows (10/5/3mm) based on motion extracted from BEV imaging of fiducial markers or the diaphragm. In order to improve motion mitigation, BEV guided gating has also been combined with either volumetric (VS) or layered (LS)more » rescanning. Nine 4DCT(MRI) liver data-sets have been used for the investigation, which not only consider realistic patient geometries but also motion variations between different breathing cycles. All 4D plans have been quantified in terms of plan homogeneity in the PTV (D5-D95), the total estimated treatment time and the beam-on duty cycle. Results: Neither gating nor rescanning can fully retrieve a comparable plan homogeneity to the static case, and considerable reductions of the duty cycle (<10%) were observed as a Result motion variations when small gating windows are used. However, once combined with rescanning, dose homogeneity within 1% of the static plan could be achieved with reasonable prolongation of the treatment time for all 9 subjects. No differences were observed between the efficacy of layered or volumetric re-scanning, or of gating signals extracted from fiducial or diaphragm motions. However, layered rescanning may be preferred over volumetric rescanning when performed in combination with gating as it is generally more time-efficient and dosimetrically robust to patient and motion variations Conclusion Combining BEV beam gating with rescanning is an efficient and effective approach to treating mobile liver tumours, and is equally effective if either the diaphragm or fiducial markers are used

  14. Ultrasonography in neuralgic amyotrophy: Sensitivity, spectrum of findings, and clinical correlations.

    PubMed

    ArÁnyi, Zsuzsanna; Csillik, Anita; DéVay, Katalin; Rosero, Maja; Barsi, PéTer; BÖhm, Josef; Schelle, Thomas

    2017-12-01

    The aim of this study was to assess the value of ultrasonography in neuralgic amyotrophy. Fifty-three patients with 70 affected nerves were examined with high-resolution ultrasound. The most commonly affected nerve was the anterior interosseous (23%). Ultrasonographic abnormalities in the affected nerves, rather than in the brachial plexus, were observed, with an overall sensitivity of 74%. Findings included the swelling of the nerve/fascicle with or without incomplete/complete constriction and rotational phenomena (nerve torsion and fascicular entwinement). A significant difference was found among the categories of ultrasonographic findings with respect to clinical outcome (P = 0.01). In nerves with complete constriction and rotational phenomena, reinnervation was absent or negligible, indicating surgery was warranted. Ultrasonography may be used as a diagnostic aid in neuralgic amyotrophy, which was hitherto a clinical and electrophysiological diagnosis, and may also help in identifying potential surgical candidates. Muscle Nerve 56: 1054-1062, 2017. © 2017 Wiley Periodicals, Inc.

  15. Age, tumor size, and in-office ultrasonography are predictive parameters of malignancy in follicular neoplasms of the thyroid.

    PubMed

    Paramo, Juan C; Mesko, Thomas

    2008-01-01

    To identify clinical predictors of malignancy in patients with intraoperative frozen-section diagnosis of follicular neoplasm of the thyroid. We performed a retrospective cross-sectional study of 71 patients with intraoperative frozen-section diagnosis of follicular neoplasm who underwent thyroidectomy between January 1992 and December 2000. Age, sex, tumor size, and in-office ultrasonography characteristics of the lesions were assessed. These clinical factors were compared between cases that had benign definitive pathologic findings and those that were found to be carcinomas on permanent sections. Nine (13%) of the 71 follicular neoplasms were found to be carcinomas after definitive pathologic evaluation. The incidence of malignancy was 13% (2/16) in men and 13% (7/55) in women (P>.5). Patients younger than 45 years had a 27% (8/30) incidence of malignancy compared with 2% (1/41) in patients 45 years or older (P<.01). Of tumors smaller than 4 cm, 7% (4/55) were ultimately diagnosed as carcinomas compared with 31% (5/16) of those 4 cm or larger (P = .05). When the in-office ultrasonography findings were interpreted as benign, only 7% (3/46) of cases were malignant compared with 40% (4/10) when the ultrasonography findings were suspicious (P = .02). Age and tumor size are predictive parameters of malignancy in follicular neoplasm of the thyroid. Suspicious ultrasonography findings also have an important predictive role. Total thyroidectomy is reasonable in patients with follicular neoplasm on frozen section if they are young (<45 years old), with large (>4 cm) tumors or if there are suspicious findings on in-office ultrasonography.

  16. Liver transplantation for fulminant hepatitis at Stanford University.

    PubMed

    Lu, Amy; Monge, Humberto; Drazan, Kenneth; Millan, Maria; Esquivel, Carlos O

    2002-01-01

    To review the clinical characteristics and outcomes of 26 patients evaluated for liver transplantation for fulminant hepatic failure at Stanford University and Lucile Packard Children's Hospital in an attempt to identify risk factors and prognostic predictors of survival. A retrospective review of the records of 26 consecutive patients who were evaluated for possible liver transplantation for acute liver failure from May 1, 1995, to January 1, 2000. Pretransplant patient demographics and clinical characteristics were collected, and the data were analyzed by univariate and multivariate analysis. Clinical assessment of encephalopathy did not predict outcome. Patients with abnormal computed tomography (CT) of the brain had a twofold increase in mortality compared with those patients with normal studies (p = 0.03). Patients requiring mechanical ventilation and continuous venovenous hemofiltration (CVVH) also had a poor prognosis. Predictors of poor outcome after fulminant hepatic failure include abnormal CT scan, mechanical ventilation, and requirement for hemofiltration.

  17. Breath-hold black-blood T1rho mapping improves liver T1rho quantification in healthy volunteers.

    PubMed

    Wáng, Yì Xiáng J; Deng, Min; Lo, Gladys G; Liang, Dong; Yuan, Jing; Chen, Weitian

    2018-03-01

    Background Recent researches suggest that T1rho may be a non-invasive and quantitative technique for detecting and grading liver fibrosis. Purpose To compare a multi-breath-hold bright-blood fast gradient echo (GRE) imaging and a single breath-hold single-shot fast spin echo (FSE) imaging with black-blood effect for liver parenchyma T1rho measurement and to study liver physiological T1rho value in healthy volunteers. Material and Methods The institutional Ethics Committee approved this study. 28 healthy participants (18 men, 10 women; age = 29.6 ± 5.1 years) underwent GRE liver T1rho imaging, and 20 healthy participants (10 men, 10 women; age = 36.9 ± 10.3 years) underwent novel black-blood FSE liver T1rho imaging, both at 3T with spin-lock frequency of 500 Hz. The FSE technique allows simultaneous acquisition of four spin lock times (TSLs; 1 ms, 10 ms, 30 ms, 50msec) in 10 s. Results For FSE technique the intra-scan repeatability intraclass correlation coefficient (ICC) was 0.98; while the inter-scan reproducibility ICC was 0.82 which is better than GRE technique's 0.76. Liver T1rho value in women tended to have a higher value than T1rho values in men (FSE: 42.28 ± 4.06 ms for women and 39.13 ± 2.12 ms for men; GRE: 44.44 ± 1.62 ms for women and 42.36 ± 2.00 ms for men) and FSE technique showed liver T1rho value decreased slightly as age increased. Conclusion Single breath-hold black-blood FSE sequence has better scan-rescan reproducibility than multi-breath-hold bright-blood GRE sequence. Gender and age dependence of liver T1rho in healthy participants is observed, with young women tending to have a higher T1rho measurement.

  18. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    PubMed

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  19. Congenital absence of the portal vein associated with focal nodular hyperplasia of the liver and congenital heart disease (Abernethy malformation): A case report and literature review

    PubMed Central

    HAO, YABIN; HONG, XU; ZHAO, XINYAN

    2015-01-01

    Abernethy malformation is a rare congenital malformation defined by an extrahepatic portosystemic shunt. The majority of affected patients are young (<18 years of age) and experience various symptoms, including vomiting, jaundice, dyspnea and coma. The current study presents a case of Abernethy malformation in an asymptomatic adult male patient. The patient exhibited congenital absence of the portal vein, congenital heart disease (postoperative ventricular septal defect status), and multiple liver lesions, confirmed to be focal nodular hyperplasia by biopsy. Ultrasonography and magnetic resonance imaging findings revealing the liver lesions, type II congenital absence of the portal vein and the portosystemic shunt are presented. In addition, the common clinical presentations, associated anomalies, diagnostic workup and treatment options of this disorder are investigated by reviewing 101 previously reported cases. PMID:25624897

  20. A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation

    PubMed Central

    2013-01-01

    Background In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnography is considered the standard of care for this purpose but is not always available and is expensive. Therefore, this feasibility study is conducted to compare a cheaper alternative, bedside upper airway ultrasonography to waveform capnography, for verification of endotracheal tube location after intubation. Methods This was a prospective, single-centre, observational study, conducted at the HRPB, Ipoh. It included patients who were intubated in the emergency department from 28 March 2012 to 17 August 2012. A waiver of consent had been obtained from the Medical Research Ethics Committee. Bedside upper airway ultrasonography was performed after intubation and compared to waveform capnography. Specificity, sensitivity, positive and negative predictive value and likelihood ratio are calculated. Results A sample of 107 patients were analysed, and 6 (5.6%) had oesophageal intubations. The overall accuracy of bedside upper airway ultrasonography was 98.1% (95% confidence interval (CI) 93.0% to 100.0%). The kappa value (Κ) was 0.85, indicating a very good agreement between the bedside upper airway ultrasonography and waveform capnography. Thus, bedside upper airway ultrasonography is in concordance with waveform capnography. The sensitivity, specificity, positive predictive value and negative predictive value of bedside upper airway ultrasonography were 98.0% (95% CI 93.0% to 99.8%), 100% (95% CI 54.1% to 100.0%), 100% (95% CI 96.3% to 100.0%) and 75.0% (95% CI 34.9% to 96.8%). The likelihood ratio of a positive test is infinite and the likelihood ratio of a negative test is 0.0198 (95% CI 0.005 to 0.0781). The mean confirmation time by ultrasound is 16.4 s. No adverse effects

  1. FibroScan, aspartate aminotransferase and alanine aminotransferase ratio (AAR), aspartate aminotransferase to platelet ratio index (APRI), fibrosis index based on the 4 factor (FIB-4), and their combinations in the assessment of liver fibrosis in patients with hepatitis B.

    PubMed

    Ding, Deping; Li, Hongbing; Liu, Ping; Chen, Lingli; Kang, Jian; Zhang, Yinhua; Ma, Deqiang; Chen, Yue; Luo, Jie; Meng, Zhongji

    2015-01-01

    The aim of this study was to assess the effects of FibroScan, aspartate aminotransferase and alanine aminotransferase ratio (AAR), aspartate aminotransferase to platelet ratio index (APRI), fibrosis index based on the 4 factor (FIB-4) and their combinations on liver fibrosis in patients with hepatitis B. 406 hospitalized patients with chronic hepatitis B (CHB) and cirrhosis in our hospital were analyzed retrospectively and collected patients clinical indicators, including liver stiffness (LS), AAR, APRI and FIB-4, and then compared the differences of these indicators between CHB group and hepatitis B with cirrhosis group. Receiver operating curve (ROC) was used to evaluate the differentiating capacity of these indicators on CHB and liver cirrhosis. Four indicators related to liver cirrhosis had a statistical significance between two groups (P < 0.01); the under ROC curve areas of LS, AAR, APRI and FIB-4 for differential diagnosis of CHB and liver cirrhosis were 0.866, 0.772, 0.632 and 0.885, respectively. The under ROC curve areas of LS, AAR, APRI and FIB-4 for differential diagnosis of liver cirrhosis at compensatory stage and de-compensatory stage were 0.627, 0.666, 0.795 and 0.820, respectively. LS, AAR, APRI and FIB-4 were good indicators as clinical diagnosis and differential diagnosis on hepatitis B related cirrhosis.

  2. Intraoperative Detection of Superficial Liver Tumors by Fluorescence Imaging Using Indocyanine Green and 5-aminolevulinic Acid.

    PubMed

    Kaibori, Masaki; Matsui, Kosuke; Ishizaki, Morihiko; Iida, Hiroya; Okumura, Tadayoshi; Sakaguchi, Tatsuma; Inoue, Kentaro; Ikeura, Tsukasa; Asano, Hiroaki; Kon, Masanori

    2016-04-01

    Indocyanine green (ICG) and the porphyrin precursor 5-aminolevulinic acid (5-ALA) have been approved as fluorescence imaging agents in the clinical setting. This study evaluated the usefulness of fluorescence imaging with both ICG and 5-ALA for intraoperative identification of latent small liver tumors. There were 48 patients who had main tumors within 5 mm of the liver surface. 5-ALA hydrochloride was orally administered to patients 3 h before surgery. ICG had been intravenously injected within 14 days prior to surgery. Intraoperatively, after visual inspection, manual palpation and ultrasonography fluorescence images of the liver surface were obtained with ICG and 5-ALA prior to resection. With ICG, the sensitivity, specificity and accuracy for detecting the preoperatively identified main tumors were 96%, 50% and 94%, respectively. Twelve latent small tumors were newly detected on the liver surface using ICG, five of which proved to be carcinomas. With 5-ALA, the sensitivity, specificity and accuracy for detecting the main tumors were 57%, 100% and 58%, respectively. Five latent small tumors were newly detected using 5-ALA; all were carcinomas. Overall, five new tumors were detected by both ICG and 5-ALA fluorescence imaging; two were hepatocellular carcinomas (HCCs) and three were metastases of colorectal cancer. The sensitivity and specificity of ICG fluorescence imaging for main tumor detection were relatively high and low, respectively, but the opposite was true of 5-ALA imaging. Fluorescence imaging using 5-ALA may provide greater specificity in the detection of surface-invisible malignant liver tumors than using ICG fluorescence imaging alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  3. Influence of Hepatic Inflammation on FibroScan Findings in Diagnosing Fibrosis in Patients with Chronic Hepatitis B.

    PubMed

    Zeng, Xianghua; Xu, Cheng; He, Dengming; Zhang, Huiyan; Xia, Jie; Shi, Dairong; Kong, Lingjun; He, Xiaoqin; Wang, Yuming

    2015-06-01

    Hepatic inflammation may affect the performance of FibroScan. This prospective study investigated the influence of hepatic inflammation on liver stiffness measurement (LSM) values by assessing FibroScan and liver biopsy findings in 325 patients with chronic hepatitis B. Liver fibrosis and inflammation were classified into five stages (S0-S4) and grades (G0-G4) according to the Scheuer scoring system. LSM values were correlated with fibrosis stage and inflammation grade (r = 0.479, p < 0.001, and r = 0.522, p < 0.001, respectively). Although LSM values increased in parallel with inflammation grade, no significant differences were found between patients with significant fibrosis (S2-S4) (p > 0.05). For inflammation grades G0, G1, G2 and G3, areas under receiver operating characteristic curves of FibroScan for significant fibrosis were 0.8267 (p < 0.001), 0.6956 (p < 0.001), 0.709 (p = 0.0012) and 0.6947 (p = 0.137), respectively. Inflammation has a significant influence on LSM values in patients with chronic hepatitis B with mild fibrosis, but not in those with significant fibrosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Fulminate Hepatic Failure as an Initial Presentation of Non-Hodgkin Lymphoma: A Case Report

    PubMed Central

    Ahmadi, Bizhan; Shafieipour, Sara; Akhavan Rezayat, Kambiz

    2014-01-01

    Viral hepatitis and toxins comprise most common causes of fulminate hepatic failure that are often diagnosed with standard laboratory tests. Herein we discuss a rare, difficult to diagnosis etiology of acute liver failure (ALF). A 62-year-old man presented with a two-week history of fever and fatigue. At four days before admission he became lethargic. His past medical and drug histories were unremarkable. Physical examination revealed generalized jaundice, fever and loss of consciousness. Laboratory tests showed elevated liver transaminases with direct hyper-bilirubinemia. Abdominal ultrasonography and CT scan showed hepatosplenomegaly and para-aortic abdominal lymphadenopathy. A further work-up included liver biopsy. The histopathology and imunohistochemistry was compatible with diffuse large B-cell lymphoma. He underwent high dose glucocorticoid therapy but his condition deteriorated rapidly and he died eight days after admission. ALF as an initial manifestation of malignant hepatic infiltration is extremely rare yet should be considered in all patients with unknown hepatic failure that are highly suspicious for malignant neoplasm. PMID:24872870

  5. Nonalcoholic Fatty Liver Disease: Noninvasive Methods of Diagnosing Hepatic Steatosis

    PubMed Central

    AlShaalan, Rasha; Aljiffry, Murad; Al-Busafi, Said; Metrakos, Peter; Hassanain, Mazen

    2015-01-01

    Hepatic steatosis is the buildup of lipids within hepatocytes. It is the simplest stage in nonalcoholic fatty liver disease (NAFLD). It occurs in approximately 30% of the general population and as much as 90% of the obese population in the United States. It may progress to nonalcoholic steatohepatitis, which is a state of hepatocellular inflammation and damage in response to the accumulated fat. Liver biopsy remains the gold standard tool to diagnose and stage NAFLD. However, it comes with the risk of complications ranging from simple pain to life-threatening bleeding. It is also associated with sampling error. For these reasons, a variety of noninvasive radiological markers, including ultrasound, computed tomography, magnetic resonance spectroscopy, and the controlled attenuation parameter using transient elastography and Xenon-133 scan have been proposed to increase our ability to diagnose NAFLD, hence avoiding liver biopsy. The aim of this review is to discuss the utility and accuracy of using available noninvasive diagnostic modalities for fatty liver in NAFLD. PMID:25843191

  6. Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

    PubMed

    Wakui, Noritaka; Takeda, Yuki; Nishinakagawa, Shuta; Ueki, Nobuo; Otsuka, Takafumi; Oba, Nobuyuki; Hashimoto, Hiroshi; Kamiyama, Naohisa; Sumino, Yasukiyo; Kojima, Tatsuya

    2015-10-01

    To prospectively clarify the effects of obstructive jaundice (OJ) on hepatic hemodynamics using contrast-enhanced ultrasonography (US). Subjects comprised 14 patients admitted to our hospital for OJ between April 2013 and March 2014. Contrast-enhanced US was performed using the LOGIQ E9 ultrasound device during the jaundice phase, before biliary drainage, and again after improvement of jaundice. After injecting the Sonazoid contrast agent, contrast dynamics were recorded in the right kidney and liver segments 5 or 6. Prototype software was used to calculate mean arrival time (AT) of the contrast agent in the liver parenchyma. Statistical analysis was performed to compare the mean AT in the jaundice and improved jaundice phases. We were unable to follow up three of the 14 patients after biliary drainage; thus, we included 11 patients for further analysis. The mean AT of the contrast agent was 2.0 ± 1.8 and 6.1 ± 2.3 s in the jaundice and improved jaundice phases, respectively, showing significantly shorter AT in the jaundice phase (p = 0.0033). Our findings indicate that OJ may influence the blood flow balance between the hepatic portal vein and hepatic artery.

  7. Serial volumetric assessment of large for size liver grafts after whole cadaveric liver transplant in adults: do large liver grafts shrink in size?

    PubMed

    Bekheit, Mohamed; Rajakannu, Muthukumarassamy; Bucur, Petru; Adam, Rene; SaCunha, Antonio; Castaing, Denis; Cherqui, Daniel; Vibert, Eric

    2016-02-01

    After whole graft orthotopic liver transplantation (OLT), adaptation of the large grafts' volume to recipient weight is widely accepted despite the paucity of evidence on this subject. Thirty nine patients with GRWR > 2.5% were included in this study and subsequently divided into two groups with 3 ≥ GRWR > 3%. Patients had CT scans at three predetermined time points after OLT used for measuring the liver volume. The objective of this study is to evaluate the volumetric changes of whole large liver grafts after adult OLT. At LT, the mean graft recipient body weight ratio (GRWR) was 3.1 ± 0.4%. The mean liver weight was 1881 ± 68 g at LT, 2014 ± 99 ml at one week, 1725 ± 126 ml at 3 months, and 1632 ± 117 (ml) at >6 months. There is an initial increase at 1 week after LT and a subsequent decrease of liver volume on later measurements. None of the late volume measurements were significantly different from the initial graft volume at liver transplant in pair wise comparisons ANOVA repeated measures (p > 0.05). Similarly, the mean GRWR did not change significantly between the initial calculation at transplantation date and the subsequent measurements during the different study time points (F = 0.04, p = 0.96) with a mean of 3.1% (95% CI = 2.2-4.2). AUC ROC discriminated a cutoff of 3% for the initial GRWR above which grafts tend to decrease in size over time (c statistics = 0.74, p = 0.036). In a Clustered ANOVA repeated measures, there was no significant difference in the changes of liver volume between both groups. However, patients with GRWR > 3 showed a trend towards a latent reduction in volume over the tracing period. There was a tendency, but none significant; towards a higher bilirubin, AST, ALT levels over the first postoperative days in recipients with GRWR > 3. Large grafts do not significantly decrease in size. Nonetheless, grafts weighing >3% of the GRWR show a different trend towards decrease in size over time. Copyright © 2015. Published by

  8. Diagnosis of a sigmoid volvulus in pregnancy: ultrasonography and magnetic resonance imaging findings

    PubMed Central

    Palmucci, Stefano; Lanza, Maria Letizia; Gulino, Fabrizio; Scilletta, Beniamino; Ettorre, Giovanni Carlo

    2014-01-01

    Sigmoid volvulus complicating pregnancy is a rare, non-obstetric cause of abdominal pain that requires prompt surgical intervention (decompression) to avoid intestinal ischemia and perforation. We report the case of a 31-week pregnant woman with abdominal pain and subsequent development of constipation. Preoperative diagnosis was achieved using magnetic resonance imaging and ultrasonography: the large bowel distension and a typical whirl sign - near a sigmoid colon transition point - suggested the diagnosis of sigmoid volvulus. The decision to refer the patient for emergency laparotomy was adopted without any ionizing radiation exposure, and the pre-operative diagnosis was confirmed after surgery. Imaging features of sigmoid volvulus and differential diagnosis from other non-obstetric abdominal emergencies in pregnancy are discussed in our report, with special emphasis on the diagnostic capabilities of ultrasonography and magnetic resonance imaging. PMID:24967020

  9. Diagnosis of a sigmoid volvulus in pregnancy: ultrasonography and magnetic resonance imaging findings.

    PubMed

    Palmucci, Stefano; Lanza, Maria Letizia; Gulino, Fabrizio; Scilletta, Beniamino; Ettorre, Giovanni Carlo

    2014-02-01

    Sigmoid volvulus complicating pregnancy is a rare, non-obstetric cause of abdominal pain that requires prompt surgical intervention (decompression) to avoid intestinal ischemia and perforation. We report the case of a 31-week pregnant woman with abdominal pain and subsequent development of constipation. Preoperative diagnosis was achieved using magnetic resonance imaging and ultrasonography: the large bowel distension and a typical whirl sign - near a sigmoid colon transition point - suggested the diagnosis of sigmoid volvulus. The decision to refer the patient for emergency laparotomy was adopted without any ionizing radiation exposure, and the pre-operative diagnosis was confirmed after surgery. Imaging features of sigmoid volvulus and differential diagnosis from other non-obstetric abdominal emergencies in pregnancy are discussed in our report, with special emphasis on the diagnostic capabilities of ultrasonography and magnetic resonance imaging.

  10. Three-dimensional growth dynamics of the liver in the human fetus.

    PubMed

    Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Badura, Mateusz; Mila-Kierzenkowska, Celestyna; Wiśniewski, Marcin

    2015-07-01

    The fetal liver is indubitably the earliest and the most severely affected organ by abnormal fetal growth. The size of the fetal liver assessed by three-dimensional ultrasonography is indispensable in determining the status of fetal growth, nutrition and maturity, and in the early recognition and monitoring fetal micro- and macrosomias. The aim of the present study was to measure the human fetal liver length, transverse and sagittal diameters to establish their age-specific reference intervals, the 3rd, 10th, 50th, 90th, and 97th smoothed centile curves, and the relative growth of the liver calculated for the 50th centile. Using anatomical, digital (NIS-Elements AR 3.0, Nikon) and statistical methods (one-way ANOVA test for paired data and post hoc RIR Tukey test, Shapiro-Wilk test, Fisher's test, Student's t test, the Altman-Chitty method), length, transverse and sagittal diameters of the liver for the 3rd, 10th, 50th, 90th, and 97th centiles were assessed in 69 human fetuses of both sexes (32 males and 37 females) aged 18-30 weeks, derived from spontaneous abortions or stillbirths. No male-female differences (P > 0.05) concerning the three parameters studied were found. During the study period, the fetal liver increased tri-dimensionally: in length from 19.51 ± 1.02 to 39.65 ± 7.05 mm, in transverse diameter from 29.44 ± 3.73 to 53.13 ± 5.31 mm, and in sagittal diameter from 22.97 ± 3.79 to 43.22 ± 5.49 mm. The natural logarithmic models were found to fit the data with gestational age (P < 0.001) in the following five cutoff points: 3rd, 10th, 50th, 90th and 97th centiles. The values of liver parameters in relation to gestational age in weeks were calculated by the following logarithmic regressions: y = -82.778 + 35.752 × ln(age) ± Z × (-2.778 + 0.308 × age) for liver length, y = -123.06 + 52.668 × ln(age) ± Z × (3.156 + 0.049 × age) for liver transverse diameter, and y = -108.94 + 46.052 × ln(age) ± Z × (-0.541 + 0.188 × age) for liver sagittal

  11. Automatic anatomical segmentation of the liver by separation planes

    NASA Astrophysics Data System (ADS)

    Boltcheva, Dobrina; Passat, Nicolas; Agnus, Vincent; Jacob-Da, Marie-Andrée, , Col; Ronse, Christian; Soler, Luc

    2006-03-01

    Surgical planning in oncological liver surgery is based on the location of the 8 anatomical segments according to Couinaud's definition and tumors inside these structures. The detection of the boundaries between the segments is then the first step of the preoperative planning. The proposed method, devoted to binary images of livers segmented from CT-scans, has been designed to delineate these segments. It automatically detects a set of landmarks using a priori anatomical knowledge and differential geometry criteria. These landmarks are then used to position the Couinaud's segments. Validations performed on 7 clinical cases tend to prove that the method is reliable for most of these separation planes.

  12. The Development of a Flexible Measuring System for Muscle Volume Using Ultrasonography

    NASA Astrophysics Data System (ADS)

    Fukumoto, Kiyotaka; Fukuda, Osamu; Tsubai, Masayoshi; Muraki, Satoshi

    Quantification of muscle volume can be used as a means for the estimation of muscle strength. Its measuring process does not need the subject's muscular contractions so it is completely safe and particularly suited for elderly people. Therefore, we have developed a flexible measuring system for muscle volume using ultrasonography. In this system, an ultrasound probe is installed on a link mechanism which continuously scans fragmental images along the human body surface. These images are then measured and composed into a wide area cross-sectional image based on the spatial compounding method. The flexibility of the link mechanism enables the operator to measure the images under any body postures and body site. The spatial compounding method significantly reduces speckle and artifact noises from the composed cross-sectional image so that the operator can observe the individual muscles, such as Rectus femoris, Vastus intermedius, and so on, in detail. We conducted the experiments in order to examine the advantages of this system we have developed. The experimental results showed a high accuracy of the measuring position which was calculated using the link mechanism and presented the noise reduction effect based on the spatial compounding method. Finally, we confirmed high correlations between the MRI images and the ones of the developed system to verify the validity of the system.

  13. Usefulness of real-time elastography strain ratio in the assessment of bile duct ligation-induced liver injury and the hepatoprotective effect of chitosan: an experimental animal study.

    PubMed

    Dudea, Marina; Clichici, Simona; Olteanu, Diana Elena; Nagy, Andras; Cucoş, Maria; Dudea, Sorin

    2015-01-01

    The purpose of the study described here was to evaluate the usefulness of the elastographic strain ratio in the assessment of liver changes in an experimental animal setting and the hepatoprotective effects of chitosan. Ultrasonography and Strain Ratio calculation were performed before and after bile duct ligation (BDL) in three groups of Wistar albino rats (n = 10 animals per group): (i) rats subjected to bile duct ligation only; (ii) rats subjected to bile duct ligation and administered chitosan for 14 d; (iii) rats subjected to bile duct ligation and administered chitosan for 7 d. The results were compared with the laboratory data and pathologic findings. Strain ratios revealed an increase in liver stiffness after bile duct ligation (p < 0.05), except in the group with chitosan administered for 7 d, and agreed with laboratory and pathology data. In conclusion, strain ratio can be used as an experimental research instrument in the assessment of liver response to injury. To the best of our knowledge, this is the first study reporting on the usefulness of the sonoelastographic liver-to-kidney strain ratio in assessing the effects of experimentally induced liver lesions. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Pathophysiology and Management of Alcoholic Liver Disease: Update 2016.

    PubMed

    Stickel, Felix; Datz, Christian; Hampe, Jochen; Bataller, Ramon

    2017-03-15

    Alcoholic liver disease (ALD) is a leading cause of cirrhosis, liver cancer, and acute and chronic liver failure and as such causes significant morbidity and mortality. While alcohol consumption is slightly decreasing in several European countries, it is rising in others and remains high in many countries around the world. The pathophysiology of ALD is still incompletely understood but relates largely to the direct toxic effects of alcohol and its main intermediate, acetaldehyde. Recently, novel putative mechanisms have been identified in systematic scans covering the entire human genome and raise new hypotheses on previously unknown pathways. The latter also identify host genetic risk factors for significant liver injury, which may help design prognostic risk scores. The diagnosis of ALD is relatively easy with a panel of well-evaluated tests and only rarely requires a liver biopsy. Treatment of ALD is difficult and grounded in abstinence as the pivotal therapeutic goal; once cirrhosis is established, treatment largely resembles that of other etiologies of advanced liver damage. Liver transplantation is a sound option for carefully selected patients with cirrhosis and alcoholic hepatitis because relapse rates are low and prognosis is comparable to other etiologies. Still, many countries are restrictive in allocating donor livers for ALD patients. Overall, few therapeutic options exist for severe ALD. However, there is good evidence of benefit for only corticosteroids in severe alcoholic hepatitis, while most other efforts are of limited efficacy. Considering the immense burden of ALD worldwide, efforts of medical professionals and industry partners to develop targeted therapies in ALF has been disappointingly low.

  15. Natural History of Cirrhosis of Liver after First Decompensation: A Prospective Study in India.

    PubMed

    Shah, Apurva S; Amarapurkar, Deepak N

    2018-03-01

    As liver cirrhosis is a dynamic condition, it is possible to improve survival in decompensated cirrhosis. Hence, we planned a prospective study to determine the natural history of cirrhosis after first decompensation. We enrolled all patients of liver cirrhosis who presented with first episode of decompensation defined by the presence of ascites, either overt or detected by Ultrasonography (UD), Gastroesophageal Variceal Bleeding (GEVB), and Hepatic Encephalopathy (HE). All patients were followed up to death/liver transplant or at least for the period of 1 year. Multivariable Cox proportional hazards regression was used to analyze the risk of failure (death or Orthotopic Liver Transplantation (OLT)). In total of 110 cirrhotic patients (93 males, mean age 50 ± 11 years), the most frequent etiology was alcohol (48%), followed by nonalcoholic steatohepatitis/cryptogenic (26%), hepatitis B (10%), autoimmune hepatitis (7%), and hepatitis C (6%). The distribution of CTP classes was: 4%, 56%, and 41% in class A, B, and C, respectively. Ascites was the most common decompensation found in 88 patients (80%) followed by HE (14%) and GEVB (6%). At 1-year follow up, transplant free survival was 78%, 2 underwent OLT, 4 developed hepatocellular carcinoma, and 24 died. Cumulative incidence of failure (death or OLT) by type of decompensation after 1 year was: 22% overt ascites, 50% GEVB, 28% UD ascites, 20% HE, and 33% ascites and GEVB concomitant. Patients with UD ascites do not have a negligible mortality rate as compared to overt ascites. Patients with cirrhosis after first decompensation have better transplant free survival with treatment of etiology and complications than previously mentioned in literature.

  16. Recent advances in the imaging of hepatocellular carcinoma. From ultrasound to positron emission tomography scan.

    PubMed

    Camaggi, Valeria; Piscaglia, Fabio; Bolondi, Luigi

    2007-07-01

    Recent advances in imaging techniques for hepatocellular carcinoma (HCC) offer the possibility of investigating contrast perfusion of liver nodules in cirrhosis. It is now accepted that a non-invasive diagnosis of HCC can be established based on the vascular pattern obtained with pure blood pool contrast agents. The diagnostic pattern consists of contrast enhancement in the arterial phase, indicative of arterial hypervascularization, followed by contrast wash out in the portal and late phases, which leads the nodule to show the same, or, more specifically, a lower contrast signal than the surrounding parenchyma. Such patterns can be obtained by CT, MRI and, more recently, by real time Contrast Enhanced Ultrasonography with second-generation ultrasound contrast agents. A typical vascular pattern in a nodule perceptible also without contrast is highly specific for HCC, so that non-invasive diagnostic algorithms have been developed and recently updated.

  17. Ultrasonography of the rumen of dairy cows

    PubMed Central

    2013-01-01

    Background This study describes the ultrasonographic findings of the rumen in 45 healthy dairy cows. Results The cows were scanned on both sides using a 5.0 MHz transducer. The dorsal visible margin of the rumen ran parallel to the lung from cranioventral to caudodorsal. It was furthest from the dorsal midline at the 9th intercostal space (48.3 ± 9.24 cm) and closest at the 12th intercostal space (22.4 ± 3.27 cm). The longitudinal groove, which could be clearly identified at all examination sites because it appeared as a triangular notch, formed the ventral margin of the dorsal sac of the rumen. The dorsal sac of the rumen was largest at the caudal flank (40.3 ± 6.33 cm), where it was adjacent to the abdominal wall. The ventral sac of the rumen extended across the ventral midline into the right hemiabdomen and its ventral margin had a largely horizontal craniocaudal course. The height of the ventral sac of the rumen exceeded that of the dorsal sac at all examination sites; the maximum height was measured at the 12th intercostal space (62.6 ± 9.53 cm). The dorsal gas cap, characterised ultrasonographically by typical reverberation artifacts, was visible in all cows from the 12th intercostal space to the caudal flank. It was largest at the 12th intercostal space (20.5 ± 7.03 cm). The transition from the gas cap to the fibre mat was marked by the abrupt cessation of the reverberation artifacts. It was not possible to differentiate a fibre mat and a ventral fluid phase. The rumen could be imaged from the right side in 21 cows (47%). Conclusions Ultrasonography is well suited for the detailed examination of the rumen of cows. The reference values obtained from this study add to the diagnostic tools that are available for the assessment of bovine patients. PMID:23497545

  18. Sporotrichal Tenosynovitis Diagnosed Helpfully by Musculoskeletal Ultrasonography

    PubMed Central

    Shimizu, Takashi; Akita, Shosuke; Harada, Yoshinori; Oguro, Eri; Okita, Yasutaka; Shigesaka, Minoru; Matsuoka, Hidetoshi; Nii, Takuro; Teshigawara, Satoru; Kudo-Tanaka, Eriko; Tsuji, Soichiro; Matsushita, Masato; Ohshima, Shiro; Hoshida, Yoshihiko; Hashimoto, Jun; Saeki, Yukihiko

    2017-01-01

    A 72-year-old man presented with persistent oligoarthritis and positive results for rheumatoid factor and was suspected of having rheumatoid arthritis (RA). However, the musculoskeletal ultrasonography (MSUS) findings were not consistent with those of typical RA. He had undergone surgery for carpal tunnel syndrome, which allowed both histopathological and microbiological examinations to be performed. A synovial tissue culture was positive for Sporothrix schenckii, and he was diagnosed with sporotrichal tenosynovitis. He received anti-fungal therapy, and the sporotrichal tenosynovitis resolved. This case suggests that MSUS is a useful modality, and sporotrichal tenosynovitis, though rare, should be considered in the differential diagnosis of RA. PMID:28502945

  19. Limitations of ultrasonography for diagnosing white matter damage in preterm infants

    PubMed Central

    Debillon, T; N'Guyen, S; Muet, A; Quere, M; Moussaly, F; Roze, J

    2003-01-01

    Objectives: To compare the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) in diagnosing white matter abnormalities in preterm infants and to determine the specific indications for MRI. Design: Prospective cohort study. Setting: A neonatal intensive care unit in France. Patients: All preterm infants (≤ 33 weeks gestation) without severe respiratory distress syndrome precluding MRI. Main outcome measures: US and MRI performed contemporaneously during the third postnatal week were analysed by an independent observer. The findings were compared with those of a term MRI scan, the results of which were taken as the final diagnosis. Statistical analysis was performed to determine which early imaging study best predicted the term MRI findings. Results: The early US and MRI findings (79 infants) correlated closely for severe lesions (cystic periventricular leucomalacia and parenchymal infarction; κ coefficient = 0.86) but not for moderate lesions (non-cystic leucomalacia and parenchymal punctate haemorrhages; κ = 0.62). Overall, early MRI findings predicted late MRI findings in 98% of patients (95% confidence interval (CI) 89.5 to 99.9) compared with only 68% for early US (95% CI 52.1 to 79.2). Conclusions: US is highly effective in detecting severe lesions of the white matter in preterm infants, but MRI seems to be necessary for the diagnosis of less severe damage. MRI performed at about the third week of life is highly predictive of the final diagnosis at term. PMID:12819157

  20. CT liver volumetry using geodesic active contour segmentation with a level-set algorithm

    NASA Astrophysics Data System (ADS)

    Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Obajuluwa, Ademola; Xu, Jianwu; Hori, Masatoshi; Baron, Richard

    2010-03-01

    Automatic liver segmentation on CT images is challenging because the liver often abuts other organs of a similar density. Our purpose was to develop an accurate automated liver segmentation scheme for measuring liver volumes. We developed an automated volumetry scheme for the liver in CT based on a 5 step schema. First, an anisotropic smoothing filter was applied to portal-venous phase CT images to remove noise while preserving the liver structure, followed by an edge enhancer to enhance the liver boundary. By using the boundary-enhanced image as a speed function, a fastmarching algorithm generated an initial surface that roughly estimated the liver shape. A geodesic-active-contour segmentation algorithm coupled with level-set contour-evolution refined the initial surface so as to more precisely fit the liver boundary. The liver volume was calculated based on the refined liver surface. Hepatic CT scans of eighteen prospective liver donors were obtained under a liver transplant protocol with a multi-detector CT system. Automated liver volumes obtained were compared with those manually traced by a radiologist, used as "gold standard." The mean liver volume obtained with our scheme was 1,520 cc, whereas the mean manual volume was 1,486 cc, with the mean absolute difference of 104 cc (7.0%). CT liver volumetrics based on an automated scheme agreed excellently with "goldstandard" manual volumetrics (intra-class correlation coefficient was 0.95) with no statistically significant difference (p(F<=f)=0.32), and required substantially less completion time. Our automated scheme provides an efficient and accurate way of measuring liver volumes.

  1. Is computed tomography volumetric assessment of the liver reliable in patients with cirrhosis?

    PubMed Central

    Goumard, Claire; Perdigao, Fabiano; Cazejust, Julien; Zalinski, Stéphane; Soubrane, Olivier; Scatton, Olivier

    2014-01-01

    Objectives: The estimation of liver volume (LV) has been widely studied in normal liver, the density of which is considered to be equivalent to 1 kg/l. In cirrhosis, volumetric evaluation and its correlation to liver mass remain unclear. The aim of this study was to evaluate the accuracy of computed tomography (CT) scanning to assess LV in patients with cirrhosis. Methods: Liver volume was evaluated by CT (CTLV) and correlated to the explanted liver weight (LW) in 49 patients. Liver density (LD) and its association with clinical features were analysed. Commonly used formulae for estimating LV were also evaluated. The real density of cirrhotic liver was prospectively measured in explant specimens. Results: Wide variations between CTLV (in ml) and LW (in g) were found (range: 3–748). Cirrhotic livers in patients with hepatitis B virus infection presented significantly increased LD (P = 0.001) with lower CTLV (P = 0.005). Liver volume as measured by CT was also decreased in patients with Model for End-stage Liver Disease scores of >15 (P = 0.023). Formulae estimating LV correlated poorly with CTLV and LW. The density of cirrhotic liver measured prospectively in 15 patients was 1.1 kg/l. Conclusions: In cirrhotic liver, LV assessed by CT did not correspond to real LW. Liver density changed according to the aetiology and severity of liver disease. Commonly used formulae did not accurately assess LV. PMID:23679861

  2. Hepatobiliary ultrasonography

    NASA Astrophysics Data System (ADS)

    Sembiring, J.

    2018-03-01

    Ultrasound is one of the most widely used imaging technologies in medicine. It is portable, free of radiation risk, non-invasive and relatively inexpensive when compared with other imaging modalities, such as magnetic resonance and computed tomography. Ultrasound is a useful procedure for evaluating many structures organ in our body. An examination may include the entirety of the abdomen and retroperitoneum from a single organ to several organs. An abdominal ultrasound examination survey would include the liver, gallbladder, biliary tree, pancreas, spleen, kidneys and retroperitoneal structures. It needsperforming when there is a valid medical reason.

  3. Prevalence and features of fatty liver detected by physical examination in Guangzhou.

    PubMed

    Liao, Xian-Hua; Cao, Xu; Liu, Jie; Xie, Xiao-Hua; Sun, Yan-Hong; Zhong, Bi-Hui

    2013-08-28

    To investigate the prevalence of fatty liver discovered upon physical examination of Chinese patients and determine the associated clinical characteristics. A total of 3433 consecutive patients who received physical examinations at the Huangpu Division of the First Affiliated Hospital at Sun Yat-sen University in Guangzhou, China from June 2010 to December 2010 were retrospectively enrolled in the study. Results of biochemical tests, abdominal ultrasound, electrocardiography, and chest X-ray were collected. The diagnosis of fatty liver was made if a patient met any two of the three following ultrasonic criteria: (1) liver and kidney echo discrepancy and presence of an increased liver echogenicity (bright); (2) unclear intrahepatic duct structure; and (3) liver far field echo decay. The study population consisted of 2201 males and 1232 females, with a mean age of 37.4 ± 12.8 years. When all 3433 patients were considered, the overall prevalence of hyperlipidemia was 38.1%, of fatty liver was 26.0%, of increased alanine aminotransferase (ALT) and/or aspartate aminotransferase (AST) levels was 11.9%, of gallstone was 11.4%, of hyperglycemia was 7.3%, of hypertension was 7.1%, and of hyperuricemia was 6.2%. Of the 2605 patients who completed the abdominal ultrasonography exam, 677 (26.0%) were diagnosed with fatty liver and the prevalence was higher in males (32.5% vs females: 15.3%, P < 0.001). The overall prevalence of fatty liver increased with age, with the peak prevalence (39.5%) found in the 60 to 70-year-old age group. Among patients between the ages of 18 to 50-year-old, the prevalence of fatty liver was significantly higher in males (20.2% vs females: 8.7%, P < 0.001); the difference in prevalence between the two sexes in patients > 50-year-old did not reach statistical significance. Only 430 of the patients diagnosed with fatty liver had complete information; among those, increased ALT and/or AST levels were detected in only 30%, with all disturbances being

  4. Sepsis resulting from Enterobacter aerogenes resistant to carbapenems after liver transplantation.

    PubMed

    Chen, Hao; Zhang, Ying; Chen, Ya-Gang; Yu, Yun-Song; Zheng, Shu-Sen; Li, Lan-Juan

    2009-06-01

    Sepsis due to Enterobacter aerogenes (E. aerogenes) is rare after liver transplantation but is also a serious infection that may cause liver abscess. The purpose of this case report is to relate an unusual presentation of liver transplantation to show how successive treatment can be an appropriate option in septic patients after liver transplantation. We report on a patient with liver transplantation who developed sepsis due to extended spectrum beta-lactamases and AmpC-producing E. aerogenes. A 39-year-old man had a biliary fistula and then was found to have multiple liver abscesses through abdominal ultrasound and an abdominal computed tomography scan, and carbapenem-sensitive E. aerogenes infection was confirmed. The patient was not successfully treated with conservative treatment consisting of intravenous carbapenems, percutaneous transhepatic cholangial drainage, and biliary stent placement by endoscopic retrograde cholangiopancreatography, so a second liver transplantation followed. Carbapenem-resistant E. aerogenes was detected in bile and blood after a five-week course of carbapenem therapy. The patient developed septic shock and multiple organ dysfunction syndrome. We first report an unusual case of sepsis caused by E. aerogenes after liver transplantation in China. Carbapenem-resistant E. aerogenes finally leads to uncontrolled sepsis with current antibiotics. We hypothesize that the infection developed as a result of biliary fistula and predisposing immunosuppressive agent therapy. Further research is progressing on the aspect of immunomodulation therapy.

  5. Evaluation of normal findings using a detailed and focused technique for transcutaneous abdominal ultrasonography in the horse

    PubMed Central

    2014-01-01

    Background Ultrasonography is an important diagnostic tool in the investigation of abdominal disease in the horse. Several factors may affect the ability to image different structures within the abdomen. The aim of the study was to describe the repeatability of identification of abdominal structures in normal horses using a detailed ultrasonographic examination technique and using a focused, limited preparation technique. Methods A detailed abdominal ultrasound examination was performed in five normal horses, repeated on five occasions (total of 25 examinations). The abdomen was divided into ten different imaging sites, and structures identified in each site were recorded. Five imaging sites were then selected for a single focused ultrasound examination in 20 normal horses. Limited patient preparation was performed. Structures were recorded as ‘identified’ if ultrasonographic features could be distinguished. The location of organs and their frequency of identification were recorded. Data from both phases were analysed to determine repeatability of identification of structures in each examination (irrespective of imaging site), and for each imaging site. Results Caecum, colon, spleen, liver and right kidney were repeatably identified using the detailed technique, and had defined locations. Large colon and right kidney were identified in 100% of examinations with both techniques. Liver, spleen, caecum, duodenum and other small intestine were identified more frequently with the detailed examination. Small intestine was most frequently identified in the ventral abdomen, its identification varied markedly within and between horses, and required repeated examinations in some horses. Left kidney could not be identified in every horse using either technique. Sacculated colon was identified in all ventral sites, and was infrequently identified in dorsal sites. Conclusions Caecum, sacculated large intestine, spleen, liver and right kidney were consistently identified

  6. Visualizing the Vibration of Laryngeal Tissue during Phonation Using Ultrafast Plane Wave Ultrasonography.

    PubMed

    Jing, Bowen; Tang, Shanshan; Wu, Liang; Wang, Supin; Wan, Mingxi

    2016-12-01

    Ultrafast plane wave ultrasonography is employed in this study to visualize the vibration of the larynx and quantify the vibration phase as well as the vibration amplitude of the laryngeal tissue. Ultrasonic images were obtained at 5000 to 10,000 frames/s in the coronal plane at the level of the glottis. Although the image quality degraded when the imaging mode was switched from conventional ultrasonography to ultrafast plane wave ultrasonography, certain anatomic structures such as the vocal folds, as well as the sub- and supraglottic structures, including the false vocal folds, can be identified in the ultrafast plane wave ultrasonic image. The periodic vibration of the vocal fold edge could be visualized in the recorded image sequence during phonation. Furthermore, a motion estimation method was used to quantify the displacement of laryngeal tissue from hundreds of frames of ultrasonic data acquired. Vibratory displacement waveforms of the sub- and supraglottic structures were successfully obtained at a high level of ultrasonic signal correlation. Moreover, statistically significant differences in vibration pattern between the sub- and supraglottic structures were found. Variation of vibration amplitude along the subglottic mucosal surface is significantly smaller than that along the supraglottic mucosal surface. Phase delay of vibration along the subglottic mucosal surface is significantly smaller than that along the supraglottic mucosal surface. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Quantitative Lingual, Pharyngeal and Laryngeal Ultrasonography in Swallowing Research: A Technical Review

    ERIC Educational Resources Information Center

    Chi-Fishman, Gloria

    2005-01-01

    Because of its distinct advantage in radiation-free soft tissue imaging, ultrasonography has been widely used to study lingual, pharyngeal, hyoid, laryngeal, and even esophageal action during swallowing in individuals of all ages. Qualitative ultrasonographic observations have made considerable contributions to our understanding of deglutition.…

  8. Radiation-induced liver injury mimicking liver metastases on FDG-PET-CT after chemoradiotherapy for esophageal cancer : A retrospective study and literature review.

    PubMed

    Voncken, Francine E M; Aleman, Berthe M P; van Dieren, Jolanda M; Grootscholten, Cecile; Lalezari, Ferry; van Sandick, Johanna W; Steinberg, Jeffrey D; Vegt, Erik

    2018-02-01

    For esophageal cancer patients treated with neoadjuvant chemoradiotherapy (nCRT), restaging using F‑18-fluorodeoxyglucose (FDG) positron emission tomography computed tomography (PET-CT) following nCRT can detect interval metastases, including liver metastases, in almost 10% of patients. However, in clinical practice, focal FDG liver uptake, unrelated to liver metastases, is observed after chemoradiotherapy. This radiation-induced liver injury (RILI) can potentially lead to overstaging. A systematic search for potential cases of RILI after (chemo)radiotherapy for esophageal cancer was performed in the electronic reports from all PET-CT scans made between 2006 and 2015 in our hospital. Additional data about potential cases were obtained from the electronic medical records. A literature review of RILI was also performed. Of 205 patients undergoing nCRT, 6 cases with localized increased FDG uptake in the caudate or left liver lobe following nCRT for esophageal cancer were identified. None of these patients had signs of liver metastases with additional imaging, during surgery, on biopsy, or during follow-up (range 11-46 months). At our institute, the incidence of RILI after neoadjuvant chemoradiotherapy for esophageal cancer was 3%. In the literature, RILI is described in about 8% of patients at the time of restaging. FDG-avid lesions occur in the high radiation dose area, usually corresponding to the caudate or left liver lobe. FDG accumulation in the caudate or left liver lobe after CRT in the area that received a high radiation dose may be caused by metastases or RILI. Awareness of the pitfall of high FDG uptake in RILI is crucial to avoid misinterpretation and overstaging.

  9. The role of ultrasonography in the management of lung and pleural diseases.

    PubMed

    Rumende, C Martin

    2012-04-01

    Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.

  10. Circulating Magnetic Microbubbles for Localized Real-Time Control of Drug Delivery by Ultrasonography-Guided Magnetic Targeting and Ultrasound

    PubMed Central

    Chertok, Beata; Langer, Robert

    2018-01-01

    Image-guided and target-selective modulation of drug delivery by external physical triggers at the site of pathology has the potential to enable tailored control of drug targeting. Magnetic microbubbles that are responsive to magnetic and acoustic modulation and visible to ultrasonography have been proposed as a means to realize this drug targeting strategy. To comply with this strategy in vivo, magnetic microbubbles must circulate systemically and evade deposition in pulmonary capillaries, while also preserving magnetic and acoustic activities in circulation over time. Unfortunately, challenges in fabricating magnetic microbubbles with such characteristics have limited progress in this field. In this report, we develop magnetic microbubbles (MagMB) that display strong magnetic and acoustic activities, while also preserving the ability to circulate systemically and evade pulmonary entrapment. Methods: We systematically evaluated the characteristics of MagMB including their pharmacokinetics, biodistribution, visibility to ultrasonography and amenability to magneto-acoustic modulation in tumor-bearing mice. We further assessed the applicability of MagMB for ultrasonography-guided control of drug targeting. Results: Following intravenous injection, MagMB exhibited a 17- to 90-fold lower pulmonary entrapment compared to previously reported magnetic microbubbles and mimicked circulation persistence of the clinically utilized Definity microbubbles (>10 min). In addition, MagMB could be accumulated in tumor vasculature by magnetic targeting, monitored by ultrasonography and collapsed by focused ultrasound on demand to activate drug deposition at the target. Furthermore, drug delivery to target tumors could be enhanced by adjusting the magneto-acoustic modulation based on ultrasonographic monitoring of MagMB in real-time. Conclusions: Circulating MagMB in conjunction with ultrasonography-guided magneto-acoustic modulation may provide a strategy for tailored minimally

  11. Assessment of the relationship between non-alcoholic fatty liver disease and diabetic complications.

    PubMed

    Yan, Li-Hui; Mu, Biao; Guan, Yue; Liu, Xinyu; Zhao, Nan; Pan, Da; Wang, Shao-Zhen

    2016-11-01

    Non-alcoholic fatty liver disease (NAFLD) is a metabolic disorder of the liver. The relationship between NAFLD and type 2 diabetes remains largely unknown. The aim of the present study was to determine the incidence of complications arising from the interaction between NAFLD and type 2 diabetes. A total of 212 individuals with type 2 diabetes were included in the study. The presence of NAFLD was determined in individuals using abdominal ultrasonography for the diagnosis of fatty liver disease. Patients were divided into three groups based on the duration of diabetes and NAFLD diagnosis. Type 2 diabetes patients were placed in group A; patients with type 2 diabetes longer than NAFLD were placed in group B; and patients with NAFLD longer than type 2 diabetes were placed in group C. All individuals had undergone electrocardiogram, blood pressure measurements, and thorough medical history and physical examinations (Doppler ultrasound, electrophysiology, fundoscopy, cardiac computed tomography). Laboratory measurements included fasting blood glucose, glycated hemoglobin, oral glucose tolerance test, liver and renal function, lipid profile, and urinary albumin excretion. Compared with groups A and B, the patients of group C showed a higher prevalence of significant coronary artery disease and hypertension (P < 0.05). Compared with groups A and B, the patients of group C showed a lower prevalence of diabetic retinopathy and diabetic peripheral neuropathy (P < 0.05). There was no significant difference in the prevalence of diabetic nephropathy among the three groups (P > 0.05). NAFLD combined with type 2 diabetes is associated with the presence of significant coronary artery disease and hypertension. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  12. Intrahepatic bile duct adenoma in a patient with chronic hepatitis B accompanied by elevation of alpha-fetoprotein.

    PubMed

    Ahn, Jem Ma; Paik, Yong-Han; Lee, Jun Hee; Cho, Ju Yeon; Sohn, Won; Gwak, Geum-Youn; Choi, Moon Seok; Lee, Joon Hyeok; Koh, Kwang Cheol; Paik, Seung Woon; Yoo, Byung Chul

    2015-12-01

    A 51-year-old male patient with chronic hepatitis B was referred to our hospital due to a 1-cm liver nodule on ultrasonography. Alpha-fetoprotein (AFP) was slightly elevated. The nodule showed prolonged enhancement on dynamic liver magnetic resonance imaging and appeared as a hyperintensity on both diffusion-weighted and T2-weighted imaging. The nodule was followed up because it was small and typical findings of hepatocellular carcinoma (HCC) were not observed in the dynamic imaging investigations. However, liver contrast-enhanced ultrasonography performed 1 month later showed enhancement during the arterial phase and definite washout during the delayed phase. Also, AFP had increased to over 200 ng/mL even though AST and ALT were decreased after administering an antiviral agent. He was presumptively diagnosed as HCC and underwent liver segmentectomy. Microscopy findings of the specimen indicated bile duct adenoma. After resection, the follow-up AFP had decreased to within the normal range. This patient represents a case of bile duct adenoma with AFP elevation mimicking HCC on contrast-enhanced ultrasonography.

  13. Non-invasive diagnostic assessment tools for the detection of liver fibrosis in patients with suspected alcohol-related liver disease: a systematic review and economic evaluation.

    PubMed

    Stevenson, M; Lloyd-Jones, M; Morgan, M Y; Wong, R

    2012-01-01

    Excessive alcohol consumption may lead to the development of alcohol-related liver disease (ALD). Liver biopsy may be used in patients with suspected ALD to confirm the diagnosis, exclude other or additional liver pathologies, and provide accurate staging of the degree of liver injury in order to enable the prediction of prognosis and inform treatment decisions. However, as it is an invasive procedure that carries the risk of morbidity and mortality, current UK guidance recommends that biopsy is not required to confirm the diagnosis in patients with a high clinical suspicion of ALD in whom blood tests have excluded other causes of liver disease, unless it is necessary to confirm a diagnosis of acute alcoholic hepatitis in order to inform specific treatment decisions. To evaluate the diagnostic accuracy, cost-effectiveness, and effect on patient outcomes of four non-invasive tests for liver fibrosis [the Enhanced Liver Fibrosis (ELF™) test (Siemens Healthcare Diagnostic Inc., Tarrytown, NY, USA), FibroTest (BioPredictive, Paris, France), FibroMAX (BioPredictive, Paris, France) and transient elastography (FibroScan(®); produced by EchoSens, Paris, France and distributed in the UK by Artemis Medical Ltd, Kent, UK)] in patients suspected of having ALD. A systematic review was undertaken to identify studies reporting the diagnostic and prognostic accuracy of the ELF test, FibroTest, FibroMAX, and FibroScan for the identification of liver fibrosis and associated conditions in patients with suspected ALD. The following databases were searched in January 2010: MEDLINE (from 1950 to January 2010), MEDLINE In-Process & Other Non-Indexed Citations (from 1950 to January 2010), EMBASE (from 1980 to January 2010), Cochrane Database of Systematic Reviews (from 1996 to January 2010), Cochrane Central Register of Controlled Trials (from 1898 to January 2010), Cochrane Methodology Register (from 1904 to January 2010), Database of Abstracts of Reviews of Effects (from 1995 to

  14. Liver metastases

    MedlinePlus

    Metastases to the liver; Metastatic liver cancer; Liver cancer - metastatic; Colorectal cancer - liver metastases; Colon cancer - liver metastases; Esophageal cancer - liver metastases; Lung cancer - liver metastases; Melanoma - liver metastases

  15. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    PubMed

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  16. Liver cancer diagnosis by fluorescence spectra of blood and urine

    NASA Astrophysics Data System (ADS)

    AlSalhi, Mohamad Saleh; Al Mehmadi, Abdulaziz Mayuof; Abdoo, Aiman; Masilamani, Vadivel

    2012-03-01

    Liver cancer or hepatocellular carcinoma (HCC) is a serious malady with only 10% survival rate. HCC incidence and mortality both are highest in China. This disease is detected and diagnosed by ultra sound, CT or MRI scans which are quite expensive. Also the discrimination between cirrhosis and HCC are poor by this imaging technique. The conventional tissue biopsy is quite invasive and painful. In this context, in the new diagnostic procedure presented in this paper, all the three liver malfunctions, particularly liver cancer, could be detected and discriminated by the spectral feature of blood and urine with accuracy about 80%. All that we need are 5 ml of blood and 5 ml of urine. Hence this inexpensive non invasive, optical technique will have significant impact in screening, diagnosis and also prognosis of HCC in large segment of people in the populous Asian countries.

  17. Accuracy of screening compression ultrasonography and clinical examination for the diagnosis of deep vein thrombosis after total hip or knee arthroplasty

    PubMed Central

    Robinson, K. Sue; Anderson, David R.; Gross, Michael; Petrie, David; Leighton, Ross; Stanish, William; Alexander, David; Mitchell, Michael; Mason, William; Flemming, Bruce; Fairhurst-Vaughan, Marlene; Gent, Michael

    1998-01-01

    Objective To determine whether compression ultrasonography or clinical examination should be considered as screening tests for the diagnosis of deep vein thrombosis (DVT) after total hip or knee arthroplasty in patients receiving warfarin prophylaxis postoperatively. Design A prospective cohort study. Setting A single tertiary care orthopedic centre. Patients One hundred and eleven patients who underwent elective total hip or knee arthroplasty were enrolled. Postoperatively the warfarin dose was adjusted daily to maintain the international normalized ratio between 1.8 and 2.5. Eighty-six patients successfully completed the study protocol. Intervention Before they were discharged from hospital, patients were assessed for DVT by clinical examination, bilateral compression ultrasonography of the proximal venous system and bilateral contrast venography. Results DVT was found in 29 patients (34%; 95% confidence interval [CI] 24% to 45%), and 6 patients (7%; 95% CI 3% to 15%) had proximal DVT. DVT developed in 18 (40%) of 45 patients who underwent total knee arthroplasty and in 11 (27%) of 41 patients who underwent total hip arthroplasty. The sensitivity of compression ultrasonography for the diagnosis of proximal DVT was 83% (95% CI 36% to 99%) and the specificity was 98% (95% CI 91% to 99%). The positive predictive value of compression ultrasonography was 71%. In contrast, clinical examination for DVT had a sensitivity of 11% (95% CI 2% to 28%) and a positive predictive value of 25%. Conclusions DVT is a common complication after total hip or knee arthroplasty. Compression ultrasonography appears to be a relatively accurate noninvasive test for diagnosing postoperative proximal DVT. In contrast, clinical examination is a very insensitive test. Whether routine use of screening compression ultrasonography will reduce the morbidity of venous thromboembolism after joint arthroplasty requires confirmation in a prospective trial involving long-term follow-up of patients

  18. Quantification of the Effect of Shuttling on Computed Tomography Perfusion Parameters by Investigation of Aortic Inputs on Different Table Positions From Shuttle-Mode Scans of Lung and Liver Tumors.

    PubMed

    Ghosh, Payel; Chandler, Adam G; Hobbs, Brian P; Sun, Jia; Rong, John; Hong, David; Subbiah, Vivek; Janku, Filip; Naing, Aung; Hwu, Wen-Jen; Ng, Chaan S

    The aim of this study was to quantify the effect of shuttling on computed tomography perfusion (CTp) parameters derived from shuttle-mode body CT images using aortic inputs from different table positions. Axial shuttle-mode CT scans were acquired from 6 patients (10 phases, 2 nonoverlapping table positions 1.4 seconds apart) after contrast agent administration. Artifacts resulting from the shuttling motion were corrected with nonrigid registration before computing CTp maps from 4 aortic levels chosen from the most superior and inferior slices of each table position scan. The effect of shuttling on CTp parameters was estimated by mean differences in mappings obtained from aortic inputs in different table positions. Shuttling effect was also quantified using 95% limits of agreement of CTp parameter differences within-table and between-table aortic positions from the interaortic mean CTp values. Blood flow, permeability surface, and hepatic arterial fraction differences were insignificant (P > 0.05) for both within-table and between-table comparisons. The 95% limits of agreement for within-table blood volume (BV) value deviations obtained from lung tumor regions were less than 4.7% (P = 0.18) compared with less than 12.2% (P = 0.003) for between-table BV value deviations. The 95% limits of agreement of within-table deviations for liver tumor regions were less than 1.9% (P = 0.55) for BV and less than 3.2% (P = 0.23) for mean transit time, whereas between-table BV and mean transit time deviations were less than 11.7% (P < 0.01) and less than 14.6% (P < 0.01), respectively. Values for normal liver tissue regions were concordant. Computed tomography perfusion parameters acquired from aortic levels within-table positions generally yielded higher agreement than mappings obtained from aortic levels between-table positions indicating differences due to shuttling effect.

  19. Role of Ultrasonography of Regional Nodal Basins in Staging Triple-Negative Breast Cancer and Implications For Local-Regional Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaitelman, Simona F., E-mail: sfshaitelman@mdanderson.org; Tereffe, Welela; Dogan, Basak E.

    2015-09-01

    Purpose: We sought to determine the rate at which regional nodal ultrasonography would increase the nodal disease stage in patients with triple-negative breast cancer (TNBC) beyond the clinical stage determined by physical examination and mammography alone, and significantly affect the treatments delivered to these patients. Methods and Materials: We retrospectively reviewed the charts of women with stages I to III TNBC who underwent physical examination, mammography, breast and regional nodal ultrasonography with needle biopsy of abnormal nodes, and definitive local-regional treatment at our institution between 2004 and 2011. The stages of these patients' disease with and without ultrasonography of the regionalmore » nodal basins were compared using the Pearson χ{sup 2} test. Definitive treatments of patients whose nodal disease was upstaged on the basis of ultrasonographic findings were compared to those of patients whose disease stage remained the same. Results: A total of 572 women met the study requirements. In 111 (19.4%) of these patients, regional nodal ultrasonography with needle biopsy resulted in an increase in disease stage from the original stage by physical examination and mammography alone. Significantly higher percentages of patients whose nodal disease was upstaged by ultrasonographic findings compared to that in patients whose disease was not upstaged underwent neoadjuvant systemic therapy (91.9% and 51.2%, respectively; P<.0001), axillary lymph node dissection (99.1% and 34.5%, respectively; P<.0001), and radiation to the regional nodal basins (88.2% and 29.1%, respectively; P<.0001). Conclusions: Regional nodal ultrasonography in TNBC frequently changes the initial clinical stage and plays an important role in treatment planning.« less

  20. Complications of high grade liver injuries: management and outcomewith focus on bile leaks.

    PubMed

    Bala, Miklosh; Gazalla, Samir Abu; Faroja, Mohammad; Bloom, Allan I; Zamir, Gideon; Rivkind, Avraham I; Almogy, Gidon

    2012-03-23

    Although liver injury scale does not predict need for surgical intervention, a high-grade complex liver injury should alert the physician to expect an increased risk of hepatic complications following trauma. The aim of the current study was to define hepatic related morbidity in patients sustaining high-grade hepatic injuries that could be safely managed non-operatively. This is a retrospective study of patients with liver injury admitted to Hadassah-Hebrew University Medical Centre over a 10-year period. Grade 3-5 injuries were considered to be high grade. Collected data included the number and types of liver-related complications. Interventions which were required for these complications in patients who survived longer than 24 hours were analysed. Of 398 patients with liver trauma, 64 (16%) were found to have high-grade liver injuries. Mechanism of injury was blunt trauma in 43 cases, and penetrating in 21. Forty patients (62%) required operative treatment. Among survivors 22 patients (47.8%) developed liver-related complications which required additional interventional treatment. Bilomas and bile leaks were diagnosed in 16 cases post-injury. The diagnosis of bile leaks was suspected with abdominal CT scan, which revealed intraabdominal collections (n = 6), and ascites (n = 2). Three patients had continuous biliary leak from intraabdominal drains left after laparotomy. Nine patients required ERCP with biliary stent placement, and 2 required percutaneous transhepatic biliary drainage. ERCP failed in one case. Four angioembolizations (AE) were performed in 3 patients for rebleeding. Surgical treatment was found to be associated with higher complication rate. AE at admission was associated with a significantly higher rate of biliary complications. There were 24 deaths (37%), the majority from uncontrolled haemorrhage (18 patients). There were only 2 hepatic-related mortalities due to liver failure. A high complication rate following high-grade liver injuries should

  1. Complications of high grade liver injuries: management and outcomewith focus on bile leaks

    PubMed Central

    2012-01-01

    Background Although liver injury scale does not predict need for surgical intervention, a high-grade complex liver injury should alert the physician to expect an increased risk of hepatic complications following trauma. The aim of the current study was to define hepatic related morbidity in patients sustaining high-grade hepatic injuries that could be safely managed non-operatively. Patients and methods This is a retrospective study of patients with liver injury admitted to Hadassah-Hebrew University Medical Centre over a 10-year period. Grade 3-5 injuries were considered to be high grade. Collected data included the number and types of liver-related complications. Interventions which were required for these complications in patients who survived longer than 24 hours were analysed. Results Of 398 patients with liver trauma, 64 (16%) were found to have high-grade liver injuries. Mechanism of injury was blunt trauma in 43 cases, and penetrating in 21. Forty patients (62%) required operative treatment. Among survivors 22 patients (47.8%) developed liver-related complications which required additional interventional treatment. Bilomas and bile leaks were diagnosed in 16 cases post-injury. The diagnosis of bile leaks was suspected with abdominal CT scan, which revealed intraabdominal collections (n = 6), and ascites (n = 2). Three patients had continuous biliary leak from intraabdominal drains left after laparotomy. Nine patients required ERCP with biliary stent placement, and 2 required percutaneous transhepatic biliary drainage. ERCP failed in one case. Four angioembolizations (AE) were performed in 3 patients for rebleeding. Surgical treatment was found to be associated with higher complication rate. AE at admission was associated with a significantly higher rate of biliary complications. There were 24 deaths (37%), the majority from uncontrolled haemorrhage (18 patients). There were only 2 hepatic-related mortalities due to liver failure. Conclusions A high

  2. Intraoperative endovascular ultrasonography

    NASA Astrophysics Data System (ADS)

    Eton, Darwin; Ahn, Samuel S.; Baker, J. D.; Pensabene, Joseph; Yeatman, Lawrence S.; Moore, Wesley S.

    1991-05-01

    The early experience using intra-operative endovascular ultrasonography (EU) is reported in eight patients undergoing lower extremity revasularization. In four patients, intra-operative EU successfully characterized inflow stenoses that were inadequately imaged with pre- operative arteriography. Two patients were found to have hemodynamically significant inflow stenoses, and were treated with intra-operative balloon angioplasty followed by repeat EU. The other two patients were found to have non-hemodynamically significant inflow stenoses requiring no treatment. Additional outflow procedures were required in all four patients. In the remaining four patients, EU was used to evaluate the completeness of TEC rotary atherectomy, of Hall oscillatory endarterectomy, of thrombectomy of the superficial femoral and popliteal arteries, and of valve lysis during in situ saphenous vein grafting, respectively. In the latter case, the valve leaflets were not clearly seen. In the other cases, EU assisted the surgeon. Angioscopy and angiography were available for comparison. In one case, angioscopy failed because of inability to clear the field while inspecting retrograde the limb of an aorto-bi-femoral graft. EU however was possible. No complications of EU occurred. EU is a safe procedure indicated when characterization of a lesion is needed prior to an intervention or when evaluation of the intervention's success is desired. We did not find it useful in valve lysis for in-site grafting.

  3. Use of colour Doppler and M-mode ultrasonography to confirm the location of an epidural catheter - a retrospective case series.

    PubMed

    Elsharkawy, Hesham; Sonny, Abraham; Govindarajan, Srinivasa Raghavan; Chan, Vincent

    2017-05-01

    Epidural anesthesia and analgesia has a reported failure rate ranging from 13% to 32%. We describe a technique using colour Doppler and M-mode ultrasonography to determine the position of the epidural catheter after placement in adults. This retrospective review included 37 adult patients who received postoperative epidural analgesia and underwent technically difficult epidural catheter placement. The demographic characteristics, type of surgery, use of ultrasonography, method of insertion, intervertebral level, and success of epidural localization using colour Doppler were noted for each patient. Pain scores on postoperative day 1 and the presence of a patchy block were also reviewed. Colour Doppler study helped to indicate the catheter's path from the skin to the epidural space during saline injection in 33 patients (89%). Saline flow within the epidural space (catheter tip confirmation) was successfully detected with colour Doppler in 25 patients (67.5%) and with M-mode ultrasonography in 28 patients (75%). Appropriate dermatomal analgesia was noted in 35 patients (94.5%) during local anesthetic infusion. Our preliminary data suggest the feasibility of using colour Doppler and M-mode ultrasonography to confirm proper epidural catheter placement.

  4. Factors Associated with Periductal Fibrosis Diagnosed by Ultrasonography Screening among a High Risk Population for Cholangiocarcinoma in Northeast Thailand.

    PubMed

    Intajarurnsan, Sutheera; Khuntikeo, Narong; Chamadol, Nittaya; Thinkhamrop, Bandit; Promthet, Supannee

    2016-01-01

    The population in northeast Thailand continues to present with hepatobiliary abnormalities, particularly periductal fibrosis (PDF) which is the result of chronic infection with liver fluke (Opisthorchis viverini; OV) and may lead to the development of cholangiocarcinoma (CCA). Although the prevalence of OV infection has been decreased due to a liver fluke control program over decades, the prevalence of PDF remains high. This study aimed to investigate demographic factors associated with PDF risk based on ultrasonography (US) screening. This cross-sectional study is part of the Cholangiocarcinoma Screening and Care Program (CASCAP), a prospective cohort study. Multiple logistic regression was used for data analysis. In 55,246 subjects, the overall prevalence of PDF was 33.0% (95%CI: 32.6 - 33.4). Males (33.9 %) were at higher risk for developing PDF than females (32.2 %) (ORcrude = 0.93; 95%CI: 0.89 - 0.96; p-value < 0.001). Factors associated with an increased PDF risk, in addition to OV infection, included old age (≥ 70 years) (ORadj =1.28, 95% CI: 1.14 - 1.44, <0.001) and hepatitis B infection (ORadj = 1.31, 95% CI: 1.11 - 1.55, p = 0.001). In contrast, number of praziquantel treatments (> 2 times) (ORadj = 0.54, 95% CI: 0.47 - 0.63, <0.001) and diabetes mellitus (ORadj =0.57, 95% CI: 0.49 - 0.65, <0.001) were significantly associated with a decreased PDF risk. Future US screening should closely examine older people and hepatitis B subjects for the purpose of PDF surveillance among high risk groups for CCA. However, the results of inverse associations require further investigation in order to confirm our findings.

  5. Short-term effects of splenectomy on serum fibrosis indexes in liver cirrhosis patients.

    PubMed

    Kong, Degang; Chen, Xiuli; Lu, Shichun; Guo, Qingliang; Lai, Wei; Wu, Jushan; Lin, Dongdong; Zeng, Daobing; Duan, Binwei; Jiang, Tao; Cao, Jilei

    2015-01-01

    To determine the changing patterns of 4 liver fibrosis markers pre and post splenectomy (combined with pericardial devascularization [PCDV]) and to examine the short-term effects of splenectomy on liver fibrosis. Four liver fibrosis markers of 39 liver cirrhosis patients were examined pre, immediately post, 2 days post, and 1 week post (15 cases) splenectomy (combined with PCDV). The laminin (LN) level decreased immediately post surgery compared with the preoperative LN level (P < 0.05). The type IV collagen level decreased immediately post surgery compared with that pre surgery (P < 0.05), it significantly increased (P < 0.05) 2 days post surgery and significantly decreased 1 week post surgery (P < 0.05). Hyaluronic acid and the procollagen III N-terminal peptide levels increased significantly 2 days post surgery compared with that pre and immediately post surgery, they significantly decreased 1 week post surgery compared to 2 days post surgery (P < 0.05). In the short-term, the 4 liver fibrosis markers and the FibroScans post splenectomy showed characteristic changes, splenectomy may transiently initiate the degradation process of liver fibrosis.

  6. [Evaluation of the learning curve of residents in localizing a phantom target with ultrasonography].

    PubMed

    Dessieux, T; Estebe, J-P; Bloc, S; Mercadal, L; Ecoffey, C

    2008-10-01

    Few information are available regarding the learning curve in ultrasonography and even less for ultrasound-guided regional anesthesia. This study aimed to evaluate in a training program the learning curve on a phantom of 12 residents novice in ultrasonography. Twelve trainees inexperienced in ultrasonography were given introductory training consisting of didactic formation on the various components of the portable ultrasound machine (i.e. on/off button, gain, depth, resolution, and image storage). Then, students performed three trials, in two sets of increased difficulty, at executing these predefined tasks: adjustments of the machine, then localization of a small plastic piece introduced into roasting pork (3 cm below the surface). At the end of the evaluation, the residents were asked to insert a 22 G needle into an exact predetermined target (i.e. point of fascia intersection). The progression of the needle was continuously controlled by ultrasound visualization using injection of a small volume of water (needle perpendicular to the longitudinal plane of the ultrasound beam). Two groups of two different examiners evaluated for each three trials the skill of the residents (quality, time to perform the machine adjustments, to localize the plastic target, and to hydrolocalize, and volume used for hydrolocalization). After each trial, residents evaluated their performance using a difficulty scale (0: easy to 10: difficult). All residents performed the adjustments from the last trial of each set, with a learning curve observed in terms of duration. Localization of the plastic piece was achieved by all residents at the 6th trial, with a shorter duration of localization. Hydrolocalization was achieved after the 4th trial by all subjects. Difficulty scale was correlated to the number of trials. All these results were independent of the experience of residents in regional anesthesia. Four trials were necessary to adjust correctly the machine, to localize a target, and to

  7. Contrast-enhanced US with Perfluorobutane(Sonazoid) used as a surveillance test for Hepatocellular Carcinoma (HCC) in Cirrhosis (SCAN): an exploratory cross-sectional study for a diagnostic trial.

    PubMed

    Park, Ji Hoon; Park, Mi-Suk; Lee, So Jung; Jeong, Woo Kyoung; Lee, Jae Young; Park, Min Jung; Han, Kyunghwa; Nam, Chung Mo; Park, Seong Ho; Lee, Kyoung Ho

    2017-04-18

    Ultrasonography (US) is widely used as a standard surveillance tool for patients who are at a high risk of having hepatocellular carcinoma (HCC); however, conventional B-mode US appears to be insufficient in order to ensure the early detection of HCC. Perfluorobutane allows very stable Kupffer phase imaging for at least 60 min, which is tolerable for examinations of the entire liver. The purpose of our study is to evaluate the added value of contrast-enhanced US using perfluorobutane to that of conventional B-mode US as an HCC surveillance tool for patients with liver cirrhosis. SCAN (Sonazoid-US for surveillance of hepatoCellulArcarciNoma) is a prospective, multi-institutional, diagnostic trial using an intra-individual comparison design in a single arm of patients. This study was approved by our five institutional review board and informed consent was obtained from all participating. We obtained consent for publication of these data (contrast enhanced US images, CT or MRI images, laboratory findings, age, sex) from all participating patients. All patients will undergo conventional B-mode US immediately followed by contrast-enhanced US. The standardized case report forms will be completed by operating radiologists after B-mode US and contrast-enhanced US, respectively. If any lesion(s) is detected, the likelihood of HCC will be recorded. The primary endpoints are a detection rate of early-stage HCC and a false referral rate of HCC. Intra-individual comparison using Mcnemar's test will be performed between B-mode US and contrast-enhanced US. The study will include 523 patients under HCC surveillance in five medical institutions in Korea. SCAN is the first study to investigate the efficacy of contrast-enhanced US in surveillance using two reciprocal endpoints specialized for the evaluation of a surveillance test. SCAN will provide evidence regarding whether patients can truly benefit from contrast-enhanced US in terms of the detection of early stage HCC while

  8. Computer-assisted surgery planning in children with complex liver tumors identifies variability of the classical Couinaud classification.

    PubMed

    Warmann, Steven W; Schenk, Andrea; Schaefer, Juergen F; Ebinger, Martin; Blumenstock, Gunnar; Tsiflikas, Ilias; Fuchs, Joerg

    2016-11-01

    In complex malignant pediatric liver tumors there is an ongoing discussion regarding surgical strategy; for example, primary organ transplantation versus extended resection in hepatoblastoma involving 3 or 4 sectors of the liver. We evaluated the possible role of computer-assisted surgery planning in children with complex hepatic tumors. Between May 2004 and March 2016, 24 Children with complex liver tumors underwent standard multislice helical CT scan or MRI scan at our institution. Imaging data were processed using the software assistant LiverAnalyzer (Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany). Results were provided as Portable Document Format (PDF) with embedded interactive 3-dimensional surface mesh models. Median age of patients was 33months. Diagnoses were hepatoblastoma (n=14), sarcoma (n=3), benign parenchyma alteration (n=2), as well as hepatocellular carcinoma, rhabdoid tumor, focal nodular hyperplasia, hemangioendothelioma, or multiple hepatic metastases of a pancreas carcinoma (each n=1). Volumetry of liver segments identified remarkable variations and substantial aberrances from the Couinaud classification. Computer-assisted surgery planning was used to determine surgical strategies in 20/24 children; this was especially relevant in tumors affecting 3 or 4 liver sectors. Primary liver transplantation could be avoided in 12 of 14 hepaoblastoma patients who theoretically were candidates for this approach. Computer-assisted surgery planning substantially contributed to the decision for surgical strategies in children with complex hepatic tumors. This tool possibly allows determination of specific surgical procedures such as extended surgical resection instead of primary transplantation in certain conditions. Copyright © 2016. Published by Elsevier Inc.

  9. [Routes of resorption of peritoneal fluid in the diaphragm in liver cirrhosis (morphologic study)].

    PubMed

    Khoroshaev, V A; Vorozheĭkin, V M; Baĭbekov, I M

    1991-01-01

    The diaphragm peritoneum from 12 operated patients and 34 patients who died from liver cirrhosis with or without ascites was studied by means of light microscopy and electron transmission and scanning microscopy. Considerable lesions are found in the peritoneum: cuboidization of mesothelial cells, basal membrane thickening, dilation of stomata, lymphatic lacunae and collectors lumina. Liver cirrhosis with ascites is frequently followed by lymphatic vessels thrombosis and firm attachment of the diaphragm to the liver resulting in the inhibition of the ascitic liquid elimination. Thus both the enhancement of liquid transudation into the abdominal cavity and the disturbance of the drainage function of the diaphragm peritoneum take place.

  10. Early Spontaneous Graft Intra- and Perihepatic Hematoma after Liver Transplantation.

    PubMed

    Lupaşcu, Cristian; Apopei, Oana; Vlad, Nutu; Vasiluta, Ciprian; Trofin, Ana-Maria; Zabara, Mihai; Vornicu, Alexandra; Lupaşcu-Ursulescu, Corina; Nitu, Mioara; Crumpei, Felicia; Braşoveanu, Vladislav; Popescu, Irinel

    2017-01-01

    Hematoma of the graft is a life threatening complication of liver transplantation (LT) and there has been no overt conclusion in the literature about optimal management except in scarcely reported cases. It may be either intrahepatic or subcapsular, then again it may develop spontaneously or following parenchimal injuries or transhepatic percutaneous invasive manoeuvers. In this report we describe a rare case of large spontaneous graft intra- and perihepatic hematoma. A 62 year-old man underwent a whole graft orthotopic liver transplantation (OLT) for decompensated chronic liver disease due to alcoholic cirrhosis. The surgical procedure was uneventful. During the early postoperative course, routine Doppler ultrasound examination and CT-scan revealed an extrahepatic paracaval hematoma, 7 days after transplantation, which was stable and conservatively managed until the 18-th postoperative day, when rapidly expanding intraparenchimal hematoma involving the right hemiliver, several other perihepatic hematomas, significant right pleural effusion and hemorrhagic ascites were described. The patient was successfully treated conservatively (nonsurgically) with slow recovery of the liver allograft and discharged one month later in good general status. Celsius.

  11. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    PubMed

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  12. Advances in diagnostic ultrasonography.

    PubMed

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  13. Liver transplant for cholestatic liver diseases.

    PubMed

    Carrion, Andres F; Bhamidimarri, Kalyan Ram

    2013-05-01

    Cholestatic liver diseases include a group of diverse disorders with different epidemiology, pathophysiology, clinical course, and prognosis. Despite significant advances in the clinical care of patients with cholestatic liver diseases, liver transplant (LT) remains the only definitive therapy for end-stage liver disease, regardless of the underlying cause. As per the United Network for Organ Sharing database, the rate of cadaveric LT for cholestatic liver disease was 18% in 1991, 10% in 2000, and 7.8% in 2008. This review summarizes the available evidence on various common and rare cholestatic liver diseases, disease-specific issues, and pertinent aspects of LT. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Liver transplant

    MedlinePlus

    ... fully working livers after a successful transplant. The donor liver is transported in a cooled salt-water (saline) ... Liver failure - liver transplant; Cirrhosis - liver transplant Images Donor liver attachment Liver transplant - series References Carrion AF, Martin ...

  15. Advantages of Whole-liver Intensity Modulated Radiation Therapy in Children With Wilms Tumor and Liver Metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalapurakal, John A., E-mail: j-kalapurakal@northwestern.edu; Pokhrel, Damodar; Gopalakrishnan, Mahesh

    Purpose: To demonstrate the dosimetric advantages of intensity modulated radiation therapy (IMRT) in children with Wilms tumor (WT) undergoing whole-liver (WL) RT. Methods and Materials: Computed tomography simulation scans of 10 children, either 3 (3D) or 4-dimensional (4D), were used for this study. The WL PTV was determined by the 3D or 4D liver volumes, with a margin of 1 cm. A total of 40 WL RT plans were performed: 10 each for left- and right-sided WT with IMRT and anteroposterior-posteroanterior (AP-PA) techniques. The radiation dose-volume coverage of the WL planning target volume (PTV), remaining kidney, and other organs weremore » analyzed and compared. Results: The 95% dose coverage to WL PTV for left and right WT were as follows: 97% ± 4% (IMRT), 83% ± 8% (AP-PA) (P<.01) and 99% ± 1% (IMRT), 94% ± 5% (AP-PA) (P<.01), respectively. When 3D WL PTV was used for RT planning, the AP-PA technique delivered 95% of dose to only 78% ± 13% and 88% ± 8% of 4D liver volume. For left WT, the right kidney V15 and V10 for IMRT were 29% ± 7% and 55% ± 8%, compared with 61% ± 29% (P<.01) and 78% ± 25% (P<.01) with AP-PA. For right WT, the left kidney V15 and V10 were 0 ± 0 and 2% ± 3% for IMRT, compared with 25% ± 19% (P<.01) and 40% ± 31% (P<.01) for AP-PA. Conclusions: The use of IMRT and 4D treatment planning resulted in the delivery of a higher RT dose to the liver compared with the standard AP-PA technique. Whole-liver IMRT also delivered a significantly lower dose to the remaining kidney.« less

  16. Multi-class SVM model for fMRI-based classification and grading of liver fibrosis

    NASA Astrophysics Data System (ADS)

    Freiman, M.; Sela, Y.; Edrei, Y.; Pappo, O.; Joskowicz, L.; Abramovitch, R.

    2010-03-01

    We present a novel non-invasive automatic method for the classification and grading of liver fibrosis from fMRI maps based on hepatic hemodynamic changes. This method automatically creates a model for liver fibrosis grading based on training datasets. Our supervised learning method evaluates hepatic hemodynamics from an anatomical MRI image and three T2*-W fMRI signal intensity time-course scans acquired during the breathing of air, air-carbon dioxide, and carbogen. It constructs a statistical model of liver fibrosis from these fMRI scans using a binary-based one-against-all multi class Support Vector Machine (SVM) classifier. We evaluated the resulting classification model with the leave-one out technique and compared it to both full multi-class SVM and K-Nearest Neighbor (KNN) classifications. Our experimental study analyzed 57 slice sets from 13 mice, and yielded a 98.2% separation accuracy between healthy and low grade fibrotic subjects, and an overall accuracy of 84.2% for fibrosis grading. These results are better than the existing image-based methods which can only discriminate between healthy and high grade fibrosis subjects. With appropriate extensions, our method may be used for non-invasive classification and progression monitoring of liver fibrosis in human patients instead of more invasive approaches, such as biopsy or contrast-enhanced imaging.

  17. Validation of Ten Noninvasive Diagnostic Models for Prediction of Liver Fibrosis in Patients with Chronic Hepatitis B

    PubMed Central

    Cheng, Jieyao; Hou, Jinlin; Ding, Huiguo; Chen, Guofeng; Xie, Qing; Wang, Yuming; Zeng, Minde; Ou, Xiaojuan; Ma, Hong; Jia, Jidong

    2015-01-01

    Background and Aims Noninvasive models have been developed for fibrosis assessment in patients with chronic hepatitis B. However, the sensitivity, specificity and diagnostic accuracy in evaluating liver fibrosis of these methods have not been validated and compared in the same group of patients. The aim of this study was to verify the diagnostic performance and reproducibility of ten reported noninvasive models in a large cohort of Asian CHB patients. Methods The diagnostic performance of ten noninvasive models (HALF index, FibroScan, S index, Zeng model, Youyi model, Hui model, APAG, APRI, FIB-4 and FibroTest) was assessed against the liver histology by ROC curve analysis in CHB patients. The reproducibility of the ten models were evaluated by recalculating the diagnostic values at the given cut-off values defined by the original studies. Results Six models (HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest) had AUROCs higher than 0.70 in predicting any fibrosis stage and 2 of them had best diagnostic performance with AUROCs to predict F≥2, F≥3 and F4 being 0.83, 0.89 and 0.89 for HALF index, 0.82, 0.87 and 0.87 for FibroScan, respectively. Four models (HALF index, FibroScan, Zeng model and Youyi model) showed good diagnostic values at given cut-offs. Conclusions HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest show a good diagnostic performance and all of them, except S index and FibroTest, have good reproducibility for evaluating liver fibrosis in CHB patients. Registration Number ChiCTR-DCS-07000039. PMID:26709706

  18. Hepatic pseudoaneurysm after traumatic liver injury; is CT follow-up warranted?

    PubMed

    Østerballe, Lene; Helgstrand, Frederik; Axelsen, Thomas; Hillingsø, Jens; Svendsen, Lars Bo

    2014-01-01

    Hepatic pseudoaneurysm (HPA) is a rare complication after liver trauma, yet it is potentially fatal, as it can lead to sudden severe haemorrhage. The risk of developing posttraumatic HPA is one of the arguments for performing follow-up CT of patients with liver injuries. The aim of this study was to investigate the occurrence of HPA post liver trauma. A retrospective study from 2000-2010 of conservatively treated patients with blunt liver trauma was performed to investigate the incidence and nature of HPA. After the initial CT scan patients were admitted to the department and if not clinically indicated prior a follow-up CT was performed on day 4-5. A total of 259 non-operatively managed patients with liver injury were reviewed. 188 had a follow-up CT or US and in 7 patients a HPA was diagnosed. All aneurysms were treated with angiographic embolization and there were no treatment failures. There was no correlation between the severity of the liver injury and development of HPA. 5 out of 7 patients were asymptomatic and would have been discharged without treatment if the protocol did not include a default follow-up CT. In conclusion, this study shows that HPA is not correlated to the severity of liver injury and it develops in 4% of patients after traumatic liver injury. In order to avoid potentially life-threatening haemorrhage from a post trauma hepatic pseudoaneurysm, it seems appropriate to do follow-up CT as part of the conservative management of blunt and penetrating liver injuries.

  19. Should Complete and Incomplete Spinal Cord Injury Patients Receive the Same Attention in Urodynamic Evaluations and Ultrasonography Examinations of the Upper Urinary Tract?

    ERIC Educational Resources Information Center

    Akkoc, Yesim; Cinar, Yasemin; Kismali, Erkan

    2012-01-01

    The aim of the study was to compare urodynamic findings and upper urinary tract (UUT) abnormalities detected by ultrasonography in complete and incomplete suprasacral spinal cord injury (SCI) patients with neurogenic detrusor overactivity. Thirty-eight suprasacral SCI patients who underwent ultrasonography evaluation of the UUT and urodynamic…

  20. Use of dynamic 3-dimensional transvaginal and transrectal ultrasonography to assess posterior pelvic floor dysfunction related to obstructed defecation.

    PubMed

    Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader

    2014-02-01

    New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and