Singla, Anand; Singla, Satpaul; Singh, Mohinder; Singla, Deeksha
2016-12-01
Acute appendicitis is a common but elusive surgical condition and remains a diagnostic dilemma. It has many clinical mimickers and diagnosis is primarily made on clinical grounds, leading to the evolution of clinical scoring systems for pin pointing the right diagnosis. The modified Alvarado and RIPASA scoring systems are two important scoring systems, for diagnosis of acute appendicitis. We prospectively compared the two scoring systems for diagnosing acute appendicitis in 50 patients presenting with right iliac fossa pain. The RIPASA score correctly classified 88 % of patients with histologically confirmed acute appendicitis compared with 48.0 % with modified Alvarado score, indicating that RIPASA score is more superior to Modified Alvarado score in our clinical settings.
Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Thumboo, Julian
2017-05-01
The aim of the study is to compare the responsiveness of two joint inflammation scoring systems (dichotomous scoring (DS) versus semi-quantitative scoring (SQS)) using novel individualized ultrasound joint selection methods and existing ultrasound joint selection methods. Responsiveness measured by the standardized response means (SRMs) using the DS and the SQS system (for both the novel and existing ultrasound joint selection methods) was derived using the baseline and the 3-month total inflammatory scores from 20 rheumatoid arthritis patients. The relative SRM gain ratios (SRM-Gains) for both scoring system (DS and SQS) comparing the novel to the existing methods were computed. Both scoring systems (DS and SQS) demonstrated substantial SRM-Gains (ranged from 3.31 to 5.67 for the DS system and ranged from 1.82 to 3.26 for the SQS system). The SRMs using the novel methods ranged from 0.94 to 1.36 for the DS system and ranged from 0.89 to 1.11 for the SQS system. The SRMs using the existing methods ranged from 0.24 to 0.32 for the DS system and ranged from 0.34 to 0.49 for the SQS system. The DS system appears to achieve high responsiveness comparable to SQS for the novel individualized ultrasound joint selection methods.
Laytin, Adam D; Dicker, Rochelle A; Gerdin, Martin; Roy, Nobhojit; Sarang, Bhakti; Kumar, Vineet; Juillard, Catherine
2017-07-01
In most low- and middle-income countries (LMICs), the resources to accurately quantify injury severity using traditional injury scoring systems are limited. Novel injury scoring systems appear to have adequate discrimination for mortality in LMIC contexts, but they have not been rigorously compared where traditional injury scores can be accurately calculated. To determine whether novel injury scoring systems perform as well as traditional ones in a HIC with complete and comprehensive data collection. Data from an American level-I trauma registry collected 2008-2013 were used to compare three traditional injury scoring systems: Injury Severity Score (ISS); Revised Trauma Score (RTS); and Trauma Injury Severity Score (TRISS); and three novel injury scoring systems: Kampala Trauma Score (KTS); Mechanism, GCS, Age and Pressure (MGAP) score; and GCS, Age and Pressure (GAP) score. Logistic regression was used to assess the association between each scoring system and mortality. Standardized regression coefficients (β 2 ), Akaike information criteria, area under the receiver operating characteristics curve, and the calibration line intercept and slope were used to evaluate the discrimination and calibration of each model. Among 18,746 patients, all six scores were associated with hospital mortality. GAP had the highest effect size, and KTS had the lowest median Akaike information criteria. Although TRISS discriminated best, the discrimination of KTS approached that of TRISS and outperformed GAP, MGAP, RTS, and ISS. MGAP was best calibrated, and KTS was better calibrated than RTS, GAP, ISS, or TRISS. The novel injury scoring systems (KTS, MGAP, and GAP), which are more feasible to calculate in low-resource settings, discriminated hospital mortality as well as traditional injury scoring systems (ISS and RTS) and approached the discrimination of a sophisticated, data-intensive injury scoring system (TRISS) in a high-resource setting. Two novel injury scoring systems (KTS and MGAP) surpassed the calibration of TRISS. These novel injury scoring systems should be considered when clinicians and researchers wish to accurately account for injury severity. Implementation of these resource-appropriate tools in LMICs can improve injury surveillance, guiding quality improvement efforts, and supporting advocacy for resource allocation commensurate with the volume and severity of trauma. Copyright © 2017 Elsevier Inc. All rights reserved.
Vingerhoets, Johan; Nijs, Steven; Tambuyzer, Lotke; Hoogstoel, Annemie; Anderson, David; Picchio, Gaston
2012-01-01
The aims of this study were to compare various genotypic scoring systems commonly used to predict virological outcome to etravirine, and examine their concordance with etravirine phenotypic susceptibility. Six etravirine genotypic scoring systems were assessed: Tibotec 2010 (based on 20 mutations; TBT 20), Monogram, Stanford HIVdb, ANRS, Rega (based on 37, 30, 27 and 49 mutations, respectively) and virco(®)TYPE HIV-1 (predicted fold change based on genotype). Samples from treatment-experienced patients who participated in the DUET trials and with both genotypic and phenotypic data (n=403) were assessed using each scoring system. Results were retrospectively correlated with virological response in DUET. κ coefficients were calculated to estimate the degree of correlation between the different scoring systems. Correlation between the five scoring systems and the TBT 20 system was approximately 90%. Virological response by etravirine susceptibility was comparable regardless of which scoring system was utilized, with 70-74% of DUET patients determined as susceptible to etravirine by the different scoring systems achieving plasma viral load <50 HIV-1 RNA copies/ml. In samples classed as phenotypically susceptible to etravirine (fold change in 50% effective concentration ≤3), correlations with genotypic score were consistently high across scoring systems (≥70%). In general, the etravirine genotypic scoring systems produced similar results, and genotype-phenotype concordance was high. As such, phenotypic interpretations, and in their absence all genotypic scoring systems investigated, may be used to reliably predict the activity of etravirine.
A Comparison of Two Scoring Methods for an Automated Speech Scoring System
ERIC Educational Resources Information Center
Xi, Xiaoming; Higgins, Derrick; Zechner, Klaus; Williamson, David
2012-01-01
This paper compares two alternative scoring methods--multiple regression and classification trees--for an automated speech scoring system used in a practice environment. The two methods were evaluated on two criteria: construct representation and empirical performance in predicting human scores. The empirical performance of the two scoring models…
Venkataraman, Ramesh; Gopichandran, Vijayaprasad; Ranganathan, Lakshmi; Rajagopal, Senthilkumar; Abraham, Babu K; Ramakrishnan, Nagarajan
2018-01-01
Background: Mortality prediction in the Intensive Care Unit (ICU) setting is complex, and there are several scoring systems utilized for this process. The Acute Physiology and Chronic Health Evaluation (APACHE) II has been the most widely used scoring system; although, the more recent APACHE IV is considered an updated and advanced prediction model. However, these two systems may not give similar mortality predictions. Objectives: The aim of this study is to compare the mortality prediction ability of APACHE II and APACHE IV scoring systems among patients admitted to a tertiary care ICU. Methods: In this prospective longitudinal observational study, APACHE II and APACHE IV scores of ICU patients were computed using an online calculator. The outcome of the ICU admissions for all the patients was collected as discharged or deceased. The data were analyzed to compare the discrimination and calibration of the mortality prediction ability of the two scores. Results: Out of the 1670 patients' data analyzed, the area under the receiver operating characteristic of APACHE II score was 0.906 (95% confidence interval [CI] – 0.890–0.992), and APACHE IV score was 0.881 (95% CI – 0.862–0.890). The mean predicted mortality rate of the study population as given by the APACHE II scoring system was 44.8 ± 26.7 and as given by APACHE IV scoring system was 29.1 ± 28.5. The observed mortality rate was 22.4%. Conclusions: The APACHE II and IV scoring systems have comparable discrimination ability, but the calibration of APACHE IV seems to be better than that of APACHE II. There is a need to recalibrate the scales with weights derived from the Indian population. PMID:29910542
Venkataraman, Ramesh; Gopichandran, Vijayaprasad; Ranganathan, Lakshmi; Rajagopal, Senthilkumar; Abraham, Babu K; Ramakrishnan, Nagarajan
2018-05-01
Mortality prediction in the Intensive Care Unit (ICU) setting is complex, and there are several scoring systems utilized for this process. The Acute Physiology and Chronic Health Evaluation (APACHE) II has been the most widely used scoring system; although, the more recent APACHE IV is considered an updated and advanced prediction model. However, these two systems may not give similar mortality predictions. The aim of this study is to compare the mortality prediction ability of APACHE II and APACHE IV scoring systems among patients admitted to a tertiary care ICU. In this prospective longitudinal observational study, APACHE II and APACHE IV scores of ICU patients were computed using an online calculator. The outcome of the ICU admissions for all the patients was collected as discharged or deceased. The data were analyzed to compare the discrimination and calibration of the mortality prediction ability of the two scores. Out of the 1670 patients' data analyzed, the area under the receiver operating characteristic of APACHE II score was 0.906 (95% confidence interval [CI] - 0.890-0.992), and APACHE IV score was 0.881 (95% CI - 0.862-0.890). The mean predicted mortality rate of the study population as given by the APACHE II scoring system was 44.8 ± 26.7 and as given by APACHE IV scoring system was 29.1 ± 28.5. The observed mortality rate was 22.4%. The APACHE II and IV scoring systems have comparable discrimination ability, but the calibration of APACHE IV seems to be better than that of APACHE II. There is a need to recalibrate the scales with weights derived from the Indian population.
Gaba, Ron C; Couture, Patrick M; Bui, James T; Knuttinen, M Grace; Walzer, Natasha M; Kallwitz, Eric R; Berkes, Jamie L; Cotler, Scott J
2013-03-01
To compare the performance of various liver disease scoring systems in predicting early mortality after transjugular intrahepatic portosystemic shunt (TIPS) creation. In this single-institution retrospective study, eight scoring systems were used to grade liver disease in 211 patients (male-to-female ratio = 131:80; mean age, 54 y) before TIPS creation from 1999-2011. Scoring systems included bilirubin level, Child-Pugh (CP) score, Model for End-Stage Liver Disease (MELD) and Model for End-Stage Liver Disease sodium (MELD-Na) score, Emory score, prognostic index (PI), Acute Physiology and Chronic Health Evaluation (APACHE) 2 score, and Bonn TIPS early mortality (BOTEM) score. Medical record review was used to identify 30-day and 90-day clinical outcomes. The relationship of scoring parameters with mortality outcomes was assessed with multivariate analysis, and the relative ability of systems to predict mortality after TIPS creation was evaluated by comparing area under receiver operating characteristic (AUROC) curves. TIPS were successfully created for variceal hemorrhage (n = 121), ascites (n = 72), hepatic hydrothorax (n = 15), and portal vein thrombosis (n = 3). All scoring systems had a significant association with 30-day and 90-day mortality (P<.050 in each case) on multivariate analysis. Based on 30-day and 90-day AUROC, MELD (0.878, 0.816) and MELD-Na (0.863, 0.823) scores had the best capability to predict early mortality compared with bilirubin (0.786, 0.749), CP (0.822, 0.771), Emory (0.786, 0.681), PI (0.854, 0.760), APACHE 2 (0.836, 0.735), and BOTEM (0.798, 0.698), with statistical superiority over bilirubin, Emory, and BOTEM scores. Several liver disease scoring systems have prognostic value for early mortality after TIPS creation. MELD and MELD-Na scores most effectively predict survival after TIPS creation. Copyright © 2013. Published by Elsevier Inc.
Moreno Berggren, Daniel; Folkvaljon, Yasin; Engvall, Marie; Sundberg, Johan; Lambe, Mats; Antunovic, Petar; Garelius, Hege; Lorenz, Fryderyk; Nilsson, Lars; Rasmussen, Bengt; Lehmann, Sören; Hellström-Lindberg, Eva; Jädersten, Martin; Ejerblad, Elisabeth
2018-06-01
The myelodysplastic syndromes (MDS) have highly variable outcomes and prognostic scoring systems are important tools for risk assessment and to guide therapeutic decisions. However, few population-based studies have compared the value of the different scoring systems. With data from the nationwide Swedish population-based MDS register we validated the International Prognostic Scoring System (IPSS), revised IPSS (IPSS-R) and the World Health Organization (WHO) Classification-based Prognostic Scoring System (WPSS). We also present population-based data on incidence, clinical characteristics including detailed cytogenetics and outcome from the register. The study encompassed 1329 patients reported to the register between 2009 and 2013, 14% of these had therapy-related MDS (t-MDS). Based on the MDS register, the yearly crude incidence of MDS in Sweden was 2·9 per 100 000 inhabitants. IPSS-R had a significantly better prognostic power than IPSS (P < 0·001). There was a trend for better prognostic power of IPSS-R compared to WPSS (P = 0·05) and for WPSS compared to IPSS (P = 0·07). IPSS-R was superior to both IPSS and WPSS for patients aged ≤70 years. Patients with t-MDS had a worse outcome compared to de novo MDS (d-MDS), however, the validity of the prognostic scoring systems was comparable for d-MDS and t-MDS. In conclusion, population-based studies are important to validate prognostic scores in a 'real-world' setting. In our nationwide cohort, the IPSS-R showed the best predictive power. © 2018 John Wiley & Sons Ltd.
Immunization-based scores as independent prognostic predictors in soft tissue sarcoma patients
Jiang, Shan-Shan; Jiang, Long; Weng, De-Sheng; Li, Yuan-fang; Pan, Qiu-Zhong; Zhao, Jing-Jing; Tang, Yan; Zhou, Zhi-Wei; Xia, Jian-Chuan
2017-01-01
Background: The purpose of this study was to examine and compare the prognostic value of different immunization-based scoring systems in patients with soft tissue sarcoma (STS). Methods: We conducted a retrospective study evaluating a cohort of 165 patients diagnosed with STS between July 2007 and July 2014. The relative Glasgow prognostic score (GPS) of these patients was calculated using 3 different systems: the traditional GPS system (tGPS), the modified GPS system 1 (m1GPS), and the modified GPS system 2 (m2GPS). Then, we evaluated the relationships between each GPS system and clinicopathological characteristics. The mean follow-up for survivors in the cohort was 73.7 months as of March 2015. Results: The most favorable overall survival (OS) rate was associated with the score 0 groups, and the poorest progression-free survival (PFS) rate was associated with the score 2 groups, regardless of which system was used to calculate the score. Specifically, the m1GPS provided the greatest accuracy in predicting OS and PFS. Moreover, the same effect was observed in a separate analysis restricted to patients with metastases. Remarkably, in patients with a score of 2 as measured by all 3 systems, local treatment resulted in a poorer prognosis compared to patients with a score of 2 who did not receive local treatment. Conclusion: The GPS is a valuable prognostic marker and has the capability to predict the appropriate treatment strategy for STS patients with metastases. The modified GPS systems demonstrated superior prognostic and predictive value compared with the traditional GPS system. PMID:28367240
A stage is a stage is a stage: a direct comparison of two scoring systems.
Dawson, Theo L
2003-09-01
L. Kohlberg (1969) argued that his moral stages captured a developmental sequence specific to the moral domain. To explore that contention, the author compared stage assignments obtained with the Standard Issue Scoring System (A. Colby & L. Kohlberg, 1987a, 1987b) and those obtained with a generalized content-independent stage-scoring system called the Hierarchical Complexity Scoring System (T. L. Dawson, 2002a), on 637 moral judgment interviews (participants' ages ranged from 5 to 86 years). The correlation between stage scores produced with the 2 systems was .88. Although standard issue scoring and hierarchical complexity scoring often awarded different scores up to Kohlberg's Moral Stage 2/3, from his Moral Stage 3 onward, scores awarded with the two systems predominantly agreed. The author explores the implications for developmental research.
Goebel, L; Zurakowski, D; Müller, A; Pape, D; Cucchiarini, M; Madry, H
2014-10-01
To compare the 2D and 3D MOCART system obtained with 9.4 T high-field magnetic resonance imaging (MRI) for the ex vivo analysis of osteochondral repair in a translational model and to correlate the data with semiquantitative histological analysis. Osteochondral samples representing all levels of repair (sheep medial femoral condyles; n = 38) were scanned in a 9.4 T high-field MRI. The 2D and adapted 3D MOCART systems were used for grading after point allocation to each category. Each score was correlated with corresponding reconstructions between both MOCART systems. Data were next correlated with corresponding categories of an elementary (Wakitani) and a complex (Sellers) histological scoring system as gold standards. Correlations between most 2D and 3D MOCART score categories were high, while mean total point values of 3D MOCART scores tended to be 15.8-16.1 points higher compared to the 2D MOCART scores based on a Bland-Altman analysis. "Defect fill" and "total points" of both MOCART scores correlated with corresponding categories of Wakitani and Sellers scores (all P ≤ 0.05). "Subchondral bone plate" also correlated between 3D MOCART and Sellers scores (P < 0.001). Most categories of the 2D and 3D MOCART systems correlate, while total scores were generally higher using the 3D MOCART system. Structural categories "total points" and "defect fill" can reliably be assessed by 9.4 T MRI evaluation using either system, "subchondral bone plate" using the 3D MOCART score. High-field MRI is valuable to objectively evaluate osteochondral repair in translational settings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Houssaini, Allal; Assoumou, Lambert; Miller, Veronica; Calvez, Vincent; Marcelin, Anne-Geneviève; Flandre, Philippe
2013-01-01
Background Several attempts have been made to determine HIV-1 resistance from genotype resistance testing. We compare scoring methods for building weighted genotyping scores and commonly used systems to determine whether the virus of a HIV-infected patient is resistant. Methods and Principal Findings Three statistical methods (linear discriminant analysis, support vector machine and logistic regression) are used to determine the weight of mutations involved in HIV resistance. We compared these weighted scores with known interpretation systems (ANRS, REGA and Stanford HIV-db) to classify patients as resistant or not. Our methodology is illustrated on the Forum for Collaborative HIV Research didanosine database (N = 1453). The database was divided into four samples according to the country of enrolment (France, USA/Canada, Italy and Spain/UK/Switzerland). The total sample and the four country-based samples allow external validation (one sample is used to estimate a score and the other samples are used to validate it). We used the observed precision to compare the performance of newly derived scores with other interpretation systems. Our results show that newly derived scores performed better than or similar to existing interpretation systems, even with external validation sets. No difference was found between the three methods investigated. Our analysis identified four new mutations associated with didanosine resistance: D123S, Q207K, H208Y and K223Q. Conclusions We explored the potential of three statistical methods to construct weighted scores for didanosine resistance. Our proposed scores performed at least as well as already existing interpretation systems and previously unrecognized didanosine-resistance associated mutations were identified. This approach could be used for building scores of genotypic resistance to other antiretroviral drugs. PMID:23555613
Rubínová, Eva; Nikolai, Tomáš; Marková, Hana; Siffelová, Kamila; Laczó, Jan; Hort, Jakub; Vyhnálek, Martin
2014-01-01
The Clock Drawing Test is a frequently used cognitive screening test with several scoring systems in elderly populations. We compare simple and complex scoring systems and evaluate the usefulness of the combination of the Clock Drawing Test with the Mini-Mental State Examination to detect patients with mild cognitive impairment. Patients with amnestic mild cognitive impairment (n = 48) and age- and education-matched controls (n = 48) underwent neuropsychological examinations, including the Clock Drawing Test and the Mini-Mental State Examination. Clock drawings were scored by three blinded raters using one simple (6-point scale) and two complex (17- and 18-point scales) systems. The sensitivity and specificity of these scoring systems used alone and in combination with the Mini-Mental State Examination were determined. Complex scoring systems, but not the simple scoring system, were significant predictors of the amnestic mild cognitive impairment diagnosis in logistic regression analysis. At equal levels of sensitivity (87.5%), the Mini-Mental State Examination showed higher specificity (31.3%, compared with 12.5% for the 17-point Clock Drawing Test scoring scale). The combination of Clock Drawing Test and Mini-Mental State Examination scores increased the area under the curve (0.72; p < .001) and increased specificity (43.8%), but did not increase sensitivity, which remained high (85.4%). A simple 6-point scoring system for the Clock Drawing Test did not differentiate between healthy elderly and patients with amnestic mild cognitive impairment in our sample. Complex scoring systems were slightly more efficient, yet still were characterized by high rates of false-positive results. We found psychometric improvement using combined scores from the Mini-Mental State Examination and the Clock Drawing Test when complex scoring systems were used. The results of this study support the benefit of using combined scores from simple methods.
An Analysis of Home Energy Score and REM/Rate Energy Simulation Results for Homes in Three Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merket, Noel D
Energy ratings and scores for homes attempt to give homeowners a understandable metric to compare the energy efficiency of homes. Two rating systems in the marketplace include RESNET's Home Energy Rating System (HERS) and DOE's Home Energy Score (HEScore) and include differing energy calculation methodologies. This report compares the energy predictions from both REM/Rate and Home Energy Score for populations of real homes in three climates and determines some features of homes that lead to the greatest differences between energy predictions.
An Evaluation of the IntelliMetric[SM] Essay Scoring System
ERIC Educational Resources Information Center
Rudner, Lawrence M.; Garcia, Veronica; Welch, Catherine
2006-01-01
This report provides a two-part evaluation of the IntelliMetric[SM] automated essay scoring system based on its performance scoring essays from the Analytic Writing Assessment of the Graduate Management Admission Test[TM] (GMAT[TM]). The IntelliMetric system performance is first compared to that of individual human raters, a Bayesian system…
ERIC Educational Resources Information Center
Bressmann, Tim; Klaiman, Paula; Fischbach, Simone
2006-01-01
Nasalance scores from the Nasometer, the NasalView and the OroNasal System were compared. The data was collected from 50 normal participants and 19 hypernasal patients with cleft palate. The Nasometer had the lowest nasalance scores for the non-nasal Zoo Passage and that the OroNasal System had the lowest nasalance scores for the Nasal Sentences.…
McLean, James M; Brumby-Rendell, Oscar; Lisle, Ryan; Brazier, Jacob; Dunn, Kieran; Gill, Tiffany; Hill, Catherine L; Mandziak, Daniel; Leith, Jordan
2018-05-01
The aim was to assess whether the Knee Society Score, Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) were comparable in asymptomatic, healthy, individuals of different age, gender and ethnicity, across two remote continents. The purpose of this study was to establish normal population values for these scores using an electronic data collection system. There is no difference in clinical knee scores in an asymptomatic population when comparing age, gender and ethnicity, across two remote continents. 312 Australian and 314 Canadian citizens, aged 18-94 years, with no active knee pain, injury or pathology in the ipsilateral knee corresponding to their dominant arm, were evaluated. A knee examination was performed and participants completed an electronically administered questionnaire covering the subjective components of the knee scores. The cohorts were age- and gender-matched. Chi-square tests, Fisher's exact test and Poisson regression models were used where appropriate, to investigate the association between knee scores, age, gender, ethnicity and nationality. There was a significant inverse relationship between age and all assessment tools. OKS recorded a significant difference between gender with females scoring on average 1% lower score. There was no significant difference between international cohorts when comparing all assessment tools. An electronic, multi-centre data collection system can be effectively utilized to assess remote international cohorts. Differences in gender, age, ethnicity and nationality should be taken into consideration when using knee scores to compare to pathological patient scores. This study has established an electronic, normal control group for future studies using the Knee society, Oxford, and KOOS knee scores. Diagnostic Level II.
Wang, Qinzhang; Qian, Biao; Li, Qiang; Ni, Zhao; Li, Yinglong; Wang, Xinmin
2015-01-01
This study aims to investigate the application of the modified R.E.N.A.L. nephrometry score system in evaluating the operation difficulty of retroperitoneal partial nephrectomy in T1 renal cell carcinoma patients. A total of 52 patients with T1 renal cell carcinoma were enrolled. They all had retroperitoneal partial nephrectomy. Their clinical data was retrospectively analyzed. R.E.N.A.L. nephrometry score system was modified based on the features of retroperitoneal partial nephrectomy. The specificity, sensitivity and Youden index were compared between R.E.N.A.L. nephrometry score system and the modified R.E.N.A.L. nephrometry score system. The effect of the modified R.E.N.A.L. nephrometry score system on perioperative outcomes was analyzed. Three degrees of operation difficulty were defined by the modified R.E.N.A.L. nephrometry score system, which included the low, medium and high degree of operation difficulty. The specificity, sensitivity and Youden index of the modified R.E.N.A.L. nephrometry score system were better than those of the original R.E.N.A.L. nephrometry score system. Compared with low degree of operation difficulty, patients with medium and high degree of operation difficulty had significantly higher levels of operative time, warm ischemia time, and intraoperative blood loss (P < 0.05). And, the levels of operative time, warm ischemia time, and intraoperative blood loss in patients with high degree were significantly higher than those in patients with medium degree (P < 0.05). The modified R.E.N.A.L. nephrometry score system has a good effect in evaluating the operation difficulty of retroperitoneal partial nephrectomy.
Noureldin, Yasser A; Elkoushy, Mohamed A; Andonian, Sero
2015-11-01
The aim of the present study was to compare the accuracy of the Guy's and S.T.O.N.E. scoring systems in predicting percutaneous nephrolithotomy (PCNL) outcomes. After obtaining ethics approval, medical records of patients undergoing PCNL between 2009 and 2013 at a tertiary stone center were retrospectively reviewed. Guy's and S.T.O.N.E. scoring systems were calculated. Regression analysis and ROC curves were performed. A total of 185 PCNLs were reviewed. The overall stone-free rate was 71.9 % with a complication rate of 16.2 %. When compared to patients with residual fragments, stone-free patients had significantly lower Guy's grade (2.7 vs. 2; p < 0.001) and S.T.O.N.E. score (8.3 vs. 7.4; p = 0.004). Logistic regression analysis showed that both Guy's and S.T.O.N.E. systems were significantly associated with stone-free status, OR 0.4 (p < 0.001), and OR 0.7 (p = 0.001), respectively. Furthermore, both scoring systems were significantly associated with the estimated blood loss (p = 0.01 and p = 0.005). There was good correlation between both scoring systems and operative time (r = 0.3, p < 0.001 and r = 0.4, p < 0.001) and length of hospital stay (r = 0.2, p = 0.001 and r = 0.3, p < 0.001). However, there were no significant associations between both scoring systems and complications (p = 0.7 and p = 0.6). There was no significant difference in the areas under the curves for the Guy's and S.T.O.N.E. scoring systems (0.74 [95 % CI 0.66-0.82] vs. 0.63 [95 % CI 0.54-0.72]; p = 0.06). Both Guy's and S.T.O.N.E scoring systems have comparable accuracies in predicting post-PCNL stone-free status. Other factors not included in either scoring system may need to be incorporated in the future to increase their accuracy.
Singla, Anurag; Khattar, Nikhil; Nayyar, Rishi; Mehra, Shibani; Goel, Hemant; Sood, Rajeev
2017-03-01
To prospectively compare the Guy's Stone Score (GSS), S.T.O.N.E. [stone size (S), tract length (T), obstruction (O), number of involved calices (N), and essence or stone density (E)] score and the Clinical Research Office of the Endourological Society (CROES) nephrolithometric nomogram to predict percutaneous nephrolithotomy (PCNL) success rate and assess the correlation with perioperative complications. We prospectively evaluated all consecutive PCNL patients at our institute between 1 November 2013 and 31 May 2015. The above scoring systems were applied to preoperative non-contrast computed tomography and the practical difficulties in such applications were noted. Perioperative complications and the stone-free rate (SFR) were also recorded. Receiver operating characteristic curves were drawn and the areas under curves were compared and appropriate statistical analysis done. In all, 48 renal units were included in the study. The overall SFR was 62.2%. The presence of staghorn stones ( β = 27.285, 95% confidence interval 1.19-625.35; P = 0.039) was the only significant variable associated with the residual stones on multivariate analysis. Stone-free patients had significantly lower median GSS (2 vs 4) and S.T.O.N.E. scores (6 vs 10) and higher median CROES scores (83% vs 63%) (all P < 0.001) compared to residual-stone patients. All scoring systems were significantly associated with SFR (all P < 0.001). There was no significant difference in the areas under curves of the scoring systems (0.858, 0.923, and 0.931, respectively). Furthermore, all scoring systems had weak correlations with Clavien-Dindo classified complications ( r = 0.29, P = 0.045; r = 0.40, P = 0.005 and r = -0.295, P = 0.04, respectively). We found no standardisation for the measurement of stone dimensions, tract length, Hounsfield units, and staghorn definition. All scoring systems equally predicted SFR and had a weak correlation with Clavien-Dindo complications. Standardisation is needed for the variables in which they have been found deficient.
ERIC Educational Resources Information Center
Mahan, Sara; Matson, Johnny L.
2011-01-01
As the "Behavioral Assessment System for Children, Second Edition" ("BASC-2") is often used to aid in diagnosis it is important to discern how children and adolescents with Autism Spectrum Disorder (ASD) score on the "BASC-2" compared to typically developing controls. This study compared scores of typically developing…
Sefton, Gerri; Lane, Steven; Killen, Roger; Black, Stuart; Lyon, Max; Ampah, Pearl; Sproule, Cathryn; Loren-Gosling, Dominic; Richards, Caitlin; Spinty, Jean; Holloway, Colette; Davies, Coral; Wilson, April; Chean, Chung Shen; Carter, Bernie; Carrol, E D
2017-05-01
Pediatric Early Warning Scores are advocated to assist health professionals to identify early signs of serious illness or deterioration in hospitalized children. Scores are derived from the weighting applied to recorded vital signs and clinical observations reflecting deviation from a predetermined "norm." Higher aggregate scores trigger an escalation in care aimed at preventing critical deterioration. Process errors made while recording these data, including plotting or calculation errors, have the potential to impede the reliability of the score. To test this hypothesis, we conducted a controlled study of documentation using five clinical vignettes. We measured the accuracy of vital sign recording, score calculation, and time taken to complete documentation using a handheld electronic physiological surveillance system, VitalPAC Pediatric, compared with traditional paper-based charts. We explored the user acceptability of both methods using a Web-based survey. Twenty-three staff participated in the controlled study. The electronic physiological surveillance system improved the accuracy of vital sign recording, 98.5% versus 85.6%, P < .02, Pediatric Early Warning Score calculation, 94.6% versus 55.7%, P < .02, and saved time, 68 versus 98 seconds, compared with paper-based documentation, P < .002. Twenty-nine staff completed the Web-based survey. They perceived that the electronic physiological surveillance system offered safety benefits by reducing human error while providing instant visibility of recorded data to the entire clinical team.
Evaluating Comparability in the Scoring of Performance Assessments for Accountability Purposes
ERIC Educational Resources Information Center
Lyons, Susan; Evans, Carla
2017-01-01
This brief summarizes "Comparability in Balanced Assessment Systems for State Accountability," published in "Educational Measurement: Issues and Practice" (Evans & Lyons 2017). The study evaluated comparability claims in local scoring of performance assessments across districts participating in New Hampshire's Performance…
Maharshi, Vikas; Nagar, Pravesh
2017-01-01
Different forms and online tools are available in different countries for spontaneous reporting, one of the most widely used methods of pharmacovigilance. Capturing sufficient information and adequate compatibility of online systems with respective reporting form is highly desirable for appropriate reporting of adverse drug reactions (ADRs). This study was aimed to compare three major online reporting systems (US, UK, and WHO) of the world and also to check their compatibility with the respective ADR reporting form. A total of 89 data elements to provide relevant information were found out from above three online reporting systems. All three online systems were compared regarding magnitude of information captured by each of them and scoring was done by providing a score of "1" to each element. Compatibility of ADR reporting forms of India (Red form), US (Form 3500), and UK (Yellow card form) was assessed by comparing the information gathered by them with that can be entered into their respective online reporting systems, namely, "VigiFlow," "US online reporting," and "Yellow card online reporting." Each unmatching item was given a score of "-1". VigiFlow scored "74" points, whereas online reporting systems of the US and UK scored "56" and "49," respectively, regarding magnitude of the information gathered by them. Compatibility score was found to be "0," "-9," and "-26" in case of ADR reporting systems of US, UK, and India, respectively. Our study reveals that "VigiFlow" is capable of capturing the maximum amount of information but "Form 3500" and "Online reporting system of US" are maximally compatible to each other among ADR reporting systems of all three countries.
Mearini, Luigi; Zucchi, Alessandro; Nunzi, Elisabetta; Di Biase, Manuel; Bini, Vittorio; Costantini, Elisabetta
2015-07-01
To date, there is no overall consensus on the definition of cure after surgery for pelvic organ prolapse (POP). The aim of the study was to design and test the scoring system S.A.C.S. (Satisfaction-Anatomy-Continence-Safety) to assess and compare the outcomes of POP repair. A total of 233 women underwent open sacrocolpopexy. The S.A.C.S. outcome scoring system was scheduled at 24 months of follow-up, and each component was detected according to: Satisfaction by mean of Patient Global Improvement Inventory scale, Anatomy by mean of POP Quantification system and bulge symptom, Continence by mean of pad use, and Safety by mean of the Clavien-Dindo classification of surgical complications. Each component produced a binary nominal categorical variable (1 or 0), with a total score of 4 representing cure. As a comparative tool, patients answered a simple yes/no question: "If you had to undergo surgery all over again, would you still do it?". The degree of concordance was estimated using Cohen's Kappa test. According to the S.A.C.S. scoring system, only 160 patients (68.6 %) reached the maximum score of cure. Sensitivity of the S.A.C.S. score was 74.1 %, specificity was 90 %, total diagnostic capacity was 75.5 %. The S.A.C.S. score internal consistency was good; the k-coefficient was higher for the satisfaction component of the score (k = 0.560). This study proposes an original, simple post-operative scoring system integrating satisfaction, anatomy, continence, and safety reports for patients undergoing surgery for POP, providing a complete, although perfectible, method to accurately report outcomes in all clinical scenarios.
Bonasia, Davide Edoardo; Marmotti, Antongiulio; Massa, Alessandro Domenico Felice; Ferro, Andrea; Blonna, Davide; Castoldi, Filippo; Rossi, Roberto
2015-09-01
In the last two decades, many surgical techniques have been described for articular cartilage repair. Reliable histological scoring systems are fundamental tools to evaluate new procedures. Several histological scoring systems have been described, and these can be divided in elementary and comprehensive scores, according to the number of sub-items. The aim of this study was to test the inter- and intra-observer reliability of ten main scores used for the histological evaluation of in vivo cartilage repair. The authors tested the starting hypothesis that elementary scores would show superior intra- and inter-observer reliability compared with comprehensive scores. Fifty histological sections obtained from the trochlea of New Zealand Rabbit and stained with Safranin-O fast green were used. The histological sections were analysed by 4 observers: 2 experienced in cartilage histology and 2 inexperienced. Histological evaluations were performed at time 1 and time 2, separated by a 30-day interval. The following scores were used: Mankin, O'Driscoll, Pineda, Wakitani, Fortier, Selleres, ICRS, ICRSII, Oswestry (OsScore) and modified O'Driscoll. Intra- and inter-observer reliability were evaluated for each score. In addition, the pavement-ceiling effect and the Bland-Altman Coefficient of Repeatability were then evaluated for each sub-item of every score. Intra-observer reliability was high for all observers in every score, even though the reliability was significantly lower for non-expert observers compared with expert counterparts. In terms of Coefficient of Repeatability, some scores performed better (O'Driscoll, Modified O'Driscoll and ICRSII) than others (Fortier, Seller). Inter-observer reliability was high for all observers in every score, but significantly lower for non-expert compared with expert observers. In expert hands, all the scores showed high intra- and inter-observer reliability, independently of the complexity. Although every score has advantages and disadvantages, ICRSII, O'Driscoll and Modified O'Driscoll scores should be preferred for the evaluation of in vivo cartilage repair in animal models.
Verma, Nupur; Hippe, Daniel S; Robinson, Jeffrey D
2016-12-01
Peer review is an important and necessary part of radiology. There are several options to perform the peer review process. This study examines the reproducibility of peer review by comparing two scoring systems. American Board of Radiology-certified radiologists from various practice environments and subspecialties were recruited to score deidentified examinations on a web-based PACS with two scoring systems, RADPEER and Cleareview. Quantitative analysis of the scores was performed for interrater agreement. Interobserver variability was high for both the RADPEER and Cleareview scoring systems. The interobserver correlations (kappa values) were 0.17-0.23 for RADPEER and 0.10-0.16 for Cleareview. Interrater correlation was not statistically significantly different when comparing the RADPEER and Cleareview systems (p = 0.07-0.27). The kappa values were low for the Cleareview subscores when we evaluated for missed findings (0.26), satisfaction of search (0.17), and inadequate interpretation of findings (0.12). Our study confirms the previous report of low interobserver correlation when using the peer review process. There was low interobserver agreement seen when using both the RADPEER and the Cleareview scoring systems.
A comparison of three developmental stage scoring systems.
Dawson, Theo Linda
2002-01-01
In social psychological research the stage metaphor has fallen into disfavor due to concerns about bias, reliability, and validity. To address some of these issues, I employ a multidimensional partial credit analysis comparing moral judgment interviews scored with the Standard Issue Scoring System (SISS) (Colby and Kohlberg, 1987b), evaluative reasoning interviews scored with the Good Life Scoring System (GLSS) (Armon, 1984b), and Good Education interviews scored with the Hierarchical Complexity Scoring System (HCSS) (Commons, Danaher, Miller, and Dawson, 2000). A total of 209 participants between the ages of 5 and 86 were interviewed. The multidimensional model reveals that even though the scoring systems rely upon different criteria and the data were collected using different methods and scored by different teams of raters, the SISS, GLSS, and HCSS all appear to measure the same latent variable. The HCSS exhibits more internal consistency than the SISS and GLSS, and solves some methodological problems introduced by the content dependency of the SISS and GLSS. These results and their implications are elaborated.
Pichonnaz, Claude; Aminian, Kamiar; Ancey, Céline; Jaccard, Hervé; Lécureux, Estelle; Duc, Cyntia; Farron, Alain; Jolles, Brigitte M; Gleeson, Nigel
2017-01-01
The B-B Score is a straightforward kinematic shoulder function score including only two movements (hand to the Back + lift hand as to change a Bulb) that demonstrated sound measurement properties for patients for various shoulder pathologies. However, the B-B Score results using a smartphone or a reference system have not yet been compared. Provided that the measurement properties are comparable, the use of a smartphone would offer substantial practical advantages. This study investigated the concurrent validity of a smartphone and a reference inertial system for the measurement of the kinematic shoulder function B-B Score. Sixty-five patients with shoulder conditions (with rotator cuff conditions, adhesive capsulitis and proximal humerus fracture) and 20 healthy participants were evaluated using a smartphone and a reference inertial system. Measurements were performed twice, alternating between two evaluators. The B-B Score differences between groups, differences between devices, relationship between devices, intra- and inter-evaluator reproducibility were analysed. The smartphone mean scores (SD) were 94.1 (11.1) for controls and 54.1 (18.3) for patients (P < 0.01). The difference between devices was non-significant for the control (P = 0.16) and the patient group (P = 0.81). The analysis of the relationship between devices showed 0.97 ICC, -0.6 bias and -13.2 to 12.0 limits of agreement (LOA). The smartphone intra-evaluator ICC was 0.92, the bias 1.5 and the LOA -17.4 to 20.3. The smartphone inter-evaluator ICC was 0.92, the bias 1.5 and the LOA -16.9 to 20.0. The B-B Score results measured with a smartphone were comparable to those of an inertial system. While single measurements diverged in some cases, the intra- and inter-evaluator reproducibility was excellent and was equivalent between devices. The B-B score measured with a smartphone is straightforward and as efficient as a reference inertial system measurement.
Aminian, Kamiar; Ancey, Céline; Jaccard, Hervé; Lécureux, Estelle; Duc, Cyntia; Farron, Alain; Jolles, Brigitte M.; Gleeson, Nigel
2017-01-01
Background The B-B Score is a straightforward kinematic shoulder function score including only two movements (hand to the Back + lift hand as to change a Bulb) that demonstrated sound measurement properties for patients for various shoulder pathologies. However, the B-B Score results using a smartphone or a reference system have not yet been compared. Provided that the measurement properties are comparable, the use of a smartphone would offer substantial practical advantages. This study investigated the concurrent validity of a smartphone and a reference inertial system for the measurement of the kinematic shoulder function B-B Score. Methods Sixty-five patients with shoulder conditions (with rotator cuff conditions, adhesive capsulitis and proximal humerus fracture) and 20 healthy participants were evaluated using a smartphone and a reference inertial system. Measurements were performed twice, alternating between two evaluators. The B-B Score differences between groups, differences between devices, relationship between devices, intra- and inter-evaluator reproducibility were analysed. Results The smartphone mean scores (SD) were 94.1 (11.1) for controls and 54.1 (18.3) for patients (P < 0.01). The difference between devices was non-significant for the control (P = 0.16) and the patient group (P = 0.81). The analysis of the relationship between devices showed 0.97 ICC, −0.6 bias and −13.2 to 12.0 limits of agreement (LOA). The smartphone intra-evaluator ICC was 0.92, the bias 1.5 and the LOA −17.4 to 20.3. The smartphone inter-evaluator ICC was 0.92, the bias 1.5 and the LOA −16.9 to 20.0. Conclusions The B-B Score results measured with a smartphone were comparable to those of an inertial system. While single measurements diverged in some cases, the intra- and inter-evaluator reproducibility was excellent and was equivalent between devices. The B-B score measured with a smartphone is straightforward and as efficient as a reference inertial system measurement. PMID:28319141
Park, Hyun Oh; Kim, Jong Woo; Kim, Sung Hwan; Moon, Seong Ho; Byun, Joung Hun; Kim, Ki Nyun; Yang, Jun Ho; Lee, Chung Eun; Jang, In Seok; Kang, Dong Hun; Kim, Seong Chun; Kang, Changwoo; Choi, Jun Young
2017-11-01
Early estimation of mortality risk in patients with trauma is essential. In this study, we evaluate the validity of the Emergency Trauma Score (EMTRAS) and Rapid Emergency Medicine Score (REMS) for predicting in-hospital mortality in patients with trauma. Furthermore, we compared the REMS and the EMTRAS with 2 other scoring systems: the Revised Trauma Score (RTS) and Injury Severity score (ISS).We performed a retrospective chart review of 6905 patients with trauma reported between July 2011 and June 2016 at a large national university hospital in South Korea. We analyzed the associations between patient characteristics, treatment course, and injury severity scoring systems (ISS, RTS, EMTRAS, and REMS) with in-hospital mortality. Discriminating power was compared between scoring systems using the areas under the curve (AUC) of receiver operating characteristic (ROC) curves.The overall in-hospital mortality rate was 3.1%. Higher EMTRAS and REMS scores were associated with hospital mortality (P < .001). The ROC curve demonstrated adequate discrimination (AUC = 0.957 for EMTRAS and 0.9 for REMS). After performing AUC analysis followed by Bonferroni correction for multiple comparisons, EMTRAS was significantly superior to REMS and ISS in predicting in-hospital mortality (P < .001), but not significantly different from the RTS (P = .057). The other scoring systems were not significantly different from each other.The EMTRAS and the REMS are simple, accurate predictors of in-hospital mortality in patients with trauma.
Armstrong, James; Forrest, Helen; Crawford, Mark W
2015-10-01
Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.
Complex and elementary histological scoring systems for articular cartilage repair.
Orth, Patrick; Madry, Henning
2015-08-01
The repair of articular cartilage defects is increasingly moving into the focus of experimental and clinical investigations. Histological analysis is the gold standard for a valid and objective evaluation of cartilaginous repair tissue and predominantly relies on the use of established scoring systems. In the past three decades, numerous elementary and complex scoring systems have been described and modified, including those of O'Driscoll, Pineda, Wakitani, Sellers and Fortier for entire defects as well as those according to the International Cartilage Repair Society (ICRS-I/II) for osteochondral tissue biopsies. Yet, this coexistence of different grading scales inconsistently addressing diverse parameters may impede comparability between reported study outcomes. Furthermore, validation of these histological scoring systems has only seldom been performed to date. The aim of this review is (1) to give a comprehensive overview and to compare the most important established histological scoring systems for articular cartilage repair, (2) to describe their specific advantages and pitfalls, and (3) to provide valid recommendations for their use in translational and clinical studies of articular cartilage repair.
Sefton, Gerri; Lane, Steven; Killen, Roger; Black, Stuart; Lyon, Max; Ampah, Pearl; Sproule, Cathryn; Loren-Gosling, Dominic; Richards, Caitlin; Spinty, Jean; Holloway, Colette; Davies, Coral; Wilson, April; Chean, Chung Shen; Carter, Bernie; Carrol, E.D.
2017-01-01
Pediatric Early Warning Scores are advocated to assist health professionals to identify early signs of serious illness or deterioration in hospitalized children. Scores are derived from the weighting applied to recorded vital signs and clinical observations reflecting deviation from a predetermined “norm.” Higher aggregate scores trigger an escalation in care aimed at preventing critical deterioration. Process errors made while recording these data, including plotting or calculation errors, have the potential to impede the reliability of the score. To test this hypothesis, we conducted a controlled study of documentation using five clinical vignettes. We measured the accuracy of vital sign recording, score calculation, and time taken to complete documentation using a handheld electronic physiological surveillance system, VitalPAC Pediatric, compared with traditional paper-based charts. We explored the user acceptability of both methods using a Web-based survey. Twenty-three staff participated in the controlled study. The electronic physiological surveillance system improved the accuracy of vital sign recording, 98.5% versus 85.6%, P < .02, Pediatric Early Warning Score calculation, 94.6% versus 55.7%, P < .02, and saved time, 68 versus 98 seconds, compared with paper-based documentation, P < .002. Twenty-nine staff completed the Web-based survey. They perceived that the electronic physiological surveillance system offered safety benefits by reducing human error while providing instant visibility of recorded data to the entire clinical team. PMID:27832032
Majid, Imran; Haq, Inaamul; Imran, Saher; Keen, Abid; Aziz, Khalid; Arif, Tasleem
2016-01-01
Background: Melasma Area and Severity Index (MASI), the scoring system in melasma, needs to be refined. Aims and Objectives: To propose a more practical scoring system, named as Melasma Severity Index (MSI), for assessing the disease severity and treatment response in melasma. Materials and Methods: Four dermatologists were trained to calculate MASI and also the proposed MSI scores. For MSI, the formula used was 0.4 (a × p2) l + 0.4 (a × p2) r + 0.2 (a × p2) n where “a” stands for area, “p” for pigmentation, “l” for left face, “r” for right face, and “n” for nose. On a single day, 30 enrolled patients were randomly examined by each trained dermatologist and their MASI and MSI scores were calculated. Next, each rater re-examined every 6th patient for repeat MASI and MSI scoring to assess intra- and inter-rater reliability of MASI and MSI scores. Validity was assessed by comparing the individual scores of each rater with objective data from mexameter and ImageJ software. Results: Inter-rater reliability, as assessed by intraclass correlation coefficient, was significantly higher for MSI (0.955) as compared to MASI (0.816). Correlation of scores with objective data by Spearman's correlation revealed higher rho values for MSI than for MASI for all raters. Limitations: Sample population belonged to a single ethnic group. Conclusions: MSI is simpler and more practical scoring system for melasma. PMID:26955093
NASA Astrophysics Data System (ADS)
Gatot, D.; Mardia, A. I.
2018-03-01
Deep Vein Thrombosis (DVT) is the venous thrombus in lower limbs. Diagnosis is by using venography or ultrasound compression. However, these examinations are not available yet in some health facilities. Therefore many scoring systems are developed for the diagnosis of DVT. The scoring method is practical and safe to use in addition to efficacy, and effectiveness in terms of treatment and costs. The existing scoring systems are wells, caprini and padua score. There have been many studies comparing the accuracy of this score but not in Medan. Therefore, we are interested in comparative research of wells, capriniand padua score in Medan.An observational, analytical, case-control study was conducted to perform diagnostic tests on the wells, caprini and padua score to predict the risk of DVT. The study was at H. Adam Malik Hospital in Medan.From a total of 72 subjects, 39 people (54.2%) are men and the mean age are 53.14 years. Wells score, caprini score and padua score has a sensitivity of 80.6%; 61.1%, 50% respectively; specificity of 80.65; 66.7%; 75% respectively, and accuracy of 87.5%; 64.3%; 65.7% respectively.Wells score has better sensitivity, specificity and accuracy than caprini and padua score in diagnosing DVT.
Jones, J Shawn; Tincher, Lindsay; Odeng-Otu, Emmanuel; Herdman, Michelle
2015-10-25
Objective. To examine whether playing a board game can assist PharmD students in learning autonomic nervous system (ANS) pharmacology. Design. Of 72 students enrolled in a required second-year pharmacology course, 22 students volunteered to play the board game, which was followed by an in-class examination consisting of 42 ANS questions (ANSQs) and 8 control questions (CTLQs). Participants were given a pretest and a posttest to assess immediate educational improvement. Participants' scores for pretest, posttest, in-class examination, and ANSQs were compared. Also, scores for examination, ANSQs, and CTLQs were compared between board game participants (PART) and nonparticipating classmates (NPART). Assessment. Board game participants scored progressively higher between the pretest, posttest, examination, and ANSQs. Additionally, PART scores were higher than NPART scores for examination and ANSQs. Difference between PART and NPART CTLQ scores was not significant. Conclusion. A board game can assist PharmD students in learning ANS pharmacology.
Lund-Mackay and modified Lund-Mackay score for sinus surgery in children with cystic fibrosis.
Do, Bao Anh; Lands, Larry C; Mascarella, Marco A; Fanous, Amanda; Saint-Martin, Christine; Manoukian, John J; Nguyen, Lily H P
2015-08-01
Patients with cystic fibrosis (CF) frequently present with severe sinonasal disease often requiring radiologic imaging and surgical intervention. Few studies have focused on the relationship between radiologic scoring systems and the need for sinus surgery in this population. The objective of this study is to evaluate the Lund-Mackay (LM) and modified Lund-Mackay (m-LM) scoring systems in predicting the need for sinus surgery or revision surgery in patients with CF. We performed a retrospective chart review of CF patients undergoing computed tomography (CT) sinus imaging at a tertiary care pediatric hospital from 1995 to 2008. Patient scans were scored using both the LM and m-LM systems and compared to the rate of sinus surgery or revision surgery. Receiver-operator characteristics curves (ROC) were used to analyze the radiological scoring systems. A total of 41 children with CF were included in the study. The mean LM score for patients undergoing surgery was 17.3 (±3.1) compared to 11.5 (±6.2) for those treated medically (p<0.01). For the m-LM, the mean score of patients undergoing surgery was 20.3 (±3.5) and 13.5 (±7.3) for those medically treated (p<0.01). Using a ROC curve with a threshold score of 13 for the LM, the sensitivity was 89.3% (95% CI of 72-98) and specificity of 69.2% (95% CI of 39-91). At an optimal score of 19, the m-LM system produced a sensitivity of 67.7% (95% CI of 48-84) and specificity of 84.6% (95% CI of 55-98). The modified Lund-Mackay score provides a high specificity while the Lund-Mackay score a high sensitivity for CF patients who required sinus surgery. The combination of both radiologic scoring systems can potentially predict the need for surgery in this population. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Kumar, Ujwal; Tomar, Vinay; Yadav, Sher Singh; Priyadarshi, Shivam; Vyas, Nachiket; Agarwal, Neeraj; Dayal, Ram
2018-01-01
Purpose: The aim of the current study was to compare Guy's score and STONE score in predicting the success and complication rate of percutaneous nephrolithotomy (PCNL). Materials and Methods: A total of 445 patients were included in the study between July 2015 and December 2016. The patients were given STONE score and Guy's Stone Score (GSS) grades based on CT scan done preoperatively and intra- and post-operative complications were graded using the modified Clavien grading system. The PCNL were done by a standard technique in prone positions. Results: The success rate in our study was 86.29% and both the GSS and STONE score were significantly associated with a success rate of the procedure. Both the scoring systems correlated with operative time and postoperative hospital stay. Of the total cases, 102 patients (22.92%) experienced complications. A correlation between STONE score stratified into low, moderate, and high nephrolithometry score risk groups (low scores 4–5, moderate scores 6–8, high scores 9–13), and complication was also found (P = 0.04) but not between the GSS and complication rate (P = 0.054). Conclusion: Both GSS and STONE scores are equally effective in predicting success rate of the procedure. PMID:29416280
POSSUM--a model for surgical outcome audit in quality care.
Ng, K J; Yii, M K
2003-10-01
Comparative surgical audit to monitor quality of care should be performed with a risk-adjusted scoring system rather than using crude morbidity and mortality rates. A validated and widely applied risk adjusted scoring system, P-POSSUM (Portsmouth-Physiological and Operative Severity Score for the enUmeration of Mortality) methodology, was applied to a prospective series of predominantly general surgical patients at the Sarawak General Hospital, Kuching over a six months period. The patients were grouped into four risk groups. The observed mortality rates were not significantly different from predicted rates, showing that the quality of surgical care was at par with typical western series. The simplicity and advantages of this scoring system over other auditing tools are discussed. The P-POSSUM methodology could form the basis of local comparative surgical audit for assessment and maintenance of quality care.
Al-Radi, Osman O; Harrell, Frank E; Caldarone, Christopher A; McCrindle, Brian W; Jacobs, Jeffrey P; Williams, M Gail; Van Arsdell, Glen S; Williams, William G
2007-04-01
The Aristotle Basic Complexity score and the Risk Adjustment in Congenital Heart Surgery system were developed by consensus to compare outcomes of congenital cardiac surgery. We compared the predictive value of the 2 systems. Of all index congenital cardiac operations at our institution from 1982 to 2004 (n = 13,675), we were able to assign an Aristotle Basic Complexity score, a Risk Adjustment in Congenital Heart Surgery score, and both scores to 13,138 (96%), 11,533 (84%), and 11,438 (84%) operations, respectively. Models of in-hospital mortality and length of stay were generated for Aristotle Basic Complexity and Risk Adjustment in Congenital Heart Surgery using an identical data set in which both Aristotle Basic Complexity and Risk Adjustment in Congenital Heart Surgery scores were assigned. The likelihood ratio test for nested models and paired concordance statistics were used. After adjustment for year of operation, the odds ratios for Aristotle Basic Complexity score 3 versus 6, 9 versus 6, 12 versus 6, and 15 versus 6 were 0.29, 2.22, 7.62, and 26.54 (P < .0001). Similarly, odds ratios for Risk Adjustment in Congenital Heart Surgery categories 1 versus 2, 3 versus 2, 4 versus 2, and 5/6 versus 2 were 0.23, 1.98, 5.80, and 20.71 (P < .0001). Risk Adjustment in Congenital Heart Surgery added significant predictive value over Aristotle Basic Complexity (likelihood ratio chi2 = 162, P < .0001), whereas Aristotle Basic Complexity contributed much less predictive value over Risk Adjustment in Congenital Heart Surgery (likelihood ratio chi2 = 13.4, P = .009). Neither system fully adjusted for the child's age. The Risk Adjustment in Congenital Heart Surgery scores were more concordant with length of stay compared with Aristotle Basic Complexity scores (P < .0001). The predictive value of Risk Adjustment in Congenital Heart Surgery is higher than that of Aristotle Basic Complexity. The use of Aristotle Basic Complexity or Risk Adjustment in Congenital Heart Surgery as risk stratification and trending tools to monitor outcomes over time and to guide risk-adjusted comparisons may be valuable.
McCollough, Cynthia H; Ulzheimer, Stefan; Halliburton, Sandra S; Shanneik, Kaiss; White, Richard D; Kalender, Willi A
2007-05-01
To develop a consensus standard for quantification of coronary artery calcium (CAC). A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.
Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Gorrissen, Willy J.
2013-01-11
The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings inmore » a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.« less
Corneal staining patterns in vernal keratoconjunctivitis: the new VKC-CLEK scoring scale.
Leonardi, Andrea; Lazzarini, Daniela; La Gloria Valerio, Alvise; Scalora, Tania; Fregona, Iva
2018-01-24
To propose a new scoring system in the assessment of ocular surface epithelial damage in vernal keratoconjunctivitis (VKC). 25 consecutive patients with VKC (50 eyes) were evaluated using the Quality of Life in children with VKC (QUICK) questionnaire and objective clinical measures: fluorescein and lissamine green staining and cornea confocal microscopy (Heidelberg Retina Tomography 3). Oxford, Van Bljsterweld and a new system, the VKC-Collaborative Longitudinal Evaluation of Keratoconus study (CLEK) (VKC-CLEK) scores, were used to evaluate the epithelial damage after staining. Mean Oxford and VKC-CLEK scores were significantly different after fluorescein staining (P<0.001), but significantly correlated (P<0.001; r=0.649). The same data were obtained comparing Van Bljsterweld and VKC-CLEK after lissamine green staining (P<0.001; r=0.760). In patient with limbal VKC, a statistically significant difference was found comparing new VKC-CLEK scores and Oxford or Van Bljsterweld scores (P<0.001), but not in tarsal VKC. A statistically superior concordance was found between QUICK and VKC-CLEK scores compared with standard staining scores values (P<0.001). Oxford and Van Bijsterveld scores are not adequate for the evaluation of the epithelial damage in patients with limbal VKC because the staining patterns considered for these tests do not correspond to the staining patterns in patients with VKC. We propose a new scoring system, VKC-CLEK, to better evaluate both limbal and tarsal epithelial damage in patients with VKC. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Maertens, H; De Reu, K; Van Weyenberg, S; Van Coillie, E; Meyer, E; Van Meirhaeghe, H; Van Immerseel, F; Vandenbroucke, V; Vanrobaeys, M; Dewulf, J
2018-02-01
Cleaning and disinfection (C&D) of poultry houses is an essential aspect in farm hygiene management. Adequate performance of the different steps of a C&D protocol and the use of suitable products are key to prevent and control zoonoses and animal diseases. Hygiene monitoring on total aerobic flora through sampling with agar contact plates at different locations of the poultry house results in a hygienogram score that is used to evaluate the proper execution of C&D.This study analyzed the hygienogram scores of 19,739 poultry flocks in Flanders after C&D. Data relating to the C&D protocol, i.e., year, season, husbandry system, production type, cleaning product, sampler, active components of the disinfectant, disinfection time, disinfection temperature, and disinfection responsible, were collected.The average hygienogram score decreased significantly over time, suggesting a general improvement between 2007 and 2014. Differences in scores were found among the husbandry systems, with the barn/aviary system having a significantly better hygienogram score compared to the floor house, furnished cage, and battery. Significantly better scores also were found when a cleaning product was used in the C&D protocol. Disinfection with a peracetic acid and hydrogen peroxide combination or formaldehyde gave the best scores. In addition, C&D protocols using ≥2 different disinfectants showed improved results compared to the use of one single disinfectant. Finally, disinfection applied by a specialist contractor resulted in a better score compared to disinfection by the farmer.In conclusion, analysis of the hygienogram scores and related data allowed identifying several factors, resulting in an improvement, which may reduce the total bacterial load in poultry stables and, consequently, the number of zoonotic and pathogenic micro-organisms. © 2017 Poultry Science Association Inc.
Hardwick, J Christopher R; MacKenzie, Fiona M
2003-01-10
To identify websites providing information about early pregnancy loss and compare this information with published guidelines from the Royal College of Obstetricians and Gynaecologists (RCOG). The value of 'Silberg' and 'Health on the net (HON)' website scoring systems in predicting the information provided via websites identified was assessed. A cross-sectional survey. Nineteen websites identified via two search engines (http://www.lycos.co.uk and http://www.msn.co.uk). Websites were searched for specific information in a structured manner and then scored by two independent observers against the website scoring systems and against a scoring system derived from guidelines published by the RCOG. Website scores against the scoring systems and against RCOG guidelines. Information concerning miscarriage contained within these websites was poor and scored accordingly against the RCOG guidelines (median score, 4.5/8). The website scoring systems did not predict the RCOG scores for a website (HON score R(S)=0.193 (95% confidence interval from -0.286 to 0.595), Silberg score, R(S)=0.035 (95% confidence interval from -0.426 to 0.482)). Few relevant websites were identified despite searching a large number via two search engines. The websites found did not answer our specific questions and consequently scored poorly against the RCOG guidelines. RCOG scores did not correlate with either scoring system. Web-based information for women attending with early pregnancy complications needs to be easily accessed and comprehensive. Written information given to women when seen with early pregnancy complications should include details of available comprehensive websites. Professional organisations, colleges or Government agencies should provide this type of information.
Bosslet, Gabriel T; Carlos, W Graham; Tybor, David J; McCallister, Jennifer; Huebert, Candace; Henderson, Ashley; Miles, Matthew C; Twigg, Homer; Sears, Catherine R; Brown, Cynthia; Farber, Mark O; Lahm, Tim; Buckley, John D
2017-04-01
Few data have been published regarding scoring tools for selection of postgraduate medical trainee candidates that have wide applicability. The authors present a novel scoring tool developed to assist postgraduate programs in generating an institution-specific rank list derived from selected elements of the U.S. Electronic Residency Application System (ERAS) application. The authors developed and validated an ERAS and interview day scoring tool at five pulmonary and critical care fellowship programs: the ERAS Application Scoring Tool-Interview Scoring Tool. This scoring tool was then tested for intrarater correlation versus subjective rankings of ERAS applications. The process for development of the tool was performed at four other institutions, and it was performed alongside and compared with the "traditional" ranking methods at the five programs and compared with the submitted National Residency Match Program rank list. The ERAS Application Scoring Tool correlated highly with subjective faculty rankings at the primary institution (average Spearman's r = 0.77). The ERAS Application Scoring Tool-Interview Scoring Tool method correlated well with traditional ranking methodology at all five institutions (Spearman's r = 0.54, 0.65, 0.72, 0.77, and 0.84). This study validates a process for selecting and weighting components of the ERAS application and interview day to create a customizable, institution-specific tool for ranking candidates to postgraduate medical education programs. This scoring system can be used in future studies to compare the outcomes of fellowship training.
Maharshi, Vikas; Nagar, Pravesh
2017-01-01
AIM: Different forms and online tools are available in different countries for spontaneous reporting, one of the most widely used methods of pharmacovigilance. Capturing sufficient information and adequate compatibility of online systems with respective reporting form is highly desirable for appropriate reporting of adverse drug reactions (ADRs). This study was aimed to compare three major online reporting systems (US, UK, and WHO) of the world and also to check their compatibility with the respective ADR reporting form. MATERIALS AND METHODS: A total of 89 data elements to provide relevant information were found out from above three online reporting systems. All three online systems were compared regarding magnitude of information captured by each of them and scoring was done by providing a score of “1” to each element. Compatibility of ADR reporting forms of India (Red form), US (Form 3500), and UK (Yellow card form) was assessed by comparing the information gathered by them with that can be entered into their respective online reporting systems, namely, “VigiFlow,” “US online reporting,” and “Yellow card online reporting.” Each unmatching item was given a score of “−1”. RESULTS: VigiFlow scored “74” points, whereas online reporting systems of the US and UK scored “56” and “49,” respectively, regarding magnitude of the information gathered by them. Compatibility score was found to be “0,” “−9,” and “−26” in case of ADR reporting systems of US, UK, and India, respectively. CONCLUSION: Our study reveals that “VigiFlow” is capable of capturing the maximum amount of information but “Form 3500” and “Online reporting system of US” are maximally compatible to each other among ADR reporting systems of all three countries. PMID:29515278
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Goel, Supriya; Gorrissen, Willy J.
2013-06-24
The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system to help building owners to evaluate the as-built physical characteristics (including building envelope, the mechanical and electrical systems) and overall building energy efficiency, independent of occupancy and operational choices. The energy asset score breaks down building energy use information by simulating building performance under typical operating and occupancy conditions for a given use type. A web-based modeling tool, the energy asset score tool facilitates the implementation of the asset score system. The tool consists of a simplified user interface built on a centralized simulation enginemore » (EnergyPlus). It is intended to reduce both the implementation cost for the users and increase modeling standardization compared with an approach that requires users to build their own energy models. A pilot project with forty-two buildings (consisting mostly offices and schools) was conducted in 2012. This paper reports the findings. Participants were asked to collect a minimum set of building data and enter it into the asset score tool. Participants also provided their utility bills, existing ENERGY STAR scores, and previous energy audit/modeling results if available. The results from the asset score tool were compared with the building energy use data provided by the pilot participants. Three comparisons were performed. First, the actual building energy use, either from the utility bills or via ENERGY STAR Portfolio Manager, was compared with the modeled energy use. It was intended to examine how well the energy asset score represents a building’s system efficiencies, and how well it is correlated to a building’s actual energy consumption. Second, calibrated building energy models (where they exist) were used to examine any discrepancies between the asset score model and the pilot participant buildings’ [known] energy use pattern. This comparison examined the end use breakdowns and more detailed time series data. Third, ASHRAE 90.1 prototype buildings were also used as an industry standard modeling approach to test the accuracy level of the asset score tool. Our analysis showed that the asset score tool, which uses simplified building simulation, could provide results comparable to a more detailed energy model. The buildings’ as-built efficiency can be reflected in the energy asset score. An analysis between the modeled energy use through the asset score tool and the actual energy use from the utility bills can further inform building owners about the effectiveness of their building’s operation and maintenance.« less
Analysis of 2009-10 WCPSS SAT Scores. Measuring Up. E&R Report No. 10.25
ERIC Educational Resources Information Center
Holdzkom, David; Gilleland, Kevin
2010-01-01
Wake County Public School System (WCPSS) students continue to fare well on the SAT test as compared with students in the state and nation. While there was a decline in average test scores in 2009-10 as compared with the prior year, the posted scores continue a trend of measurable improvement over time. Over the past 20 years, the average SAT…
Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah
2017-01-01
Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (P<0.001) for both scoring systems. Based on the results of this study, the RIPASA score is a simple scoring system with better sensitivity and specificity than the modified Alvarado scoring system in Asian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado scoring system for Kuwait population.
Rasch analysis of the Edmonton Symptom Assessment System and research implications.
Cheifetz, O; Packham, T L; Macdermid, J C
2014-04-01
Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Polytomous Rasch analysis (Andrich's rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. The Rasch reliability index was 0.73, falling short of the desired 0.80-0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0-10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions.
Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue
2017-12-01
This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (P<0.0001). The two-step scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.
Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A
2014-02-01
To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.
[Application of HIS Hospital Management System in Medical Equipment].
Li, Yucheng
2015-07-01
To analyze the effect of HIS hospital management system in medical equipment. From April 2012 to 2013 in our hospital 5 100 sets of medical equipment as the control group, another 2013 in our hospital from April 2014 may 100 sets of medical equipment as the study group, comparative analysis of two groups of medical equipment scrap rate, usage, maintenance score and the score of benefit etc. Control group and taken to hospital information system, his research group equipment scrap rate, there was a significant difference, the research group of equipment maintenance score and efficiency scores were higher than those of the control group (P < 0.05), the study group of equipment maintenance score and efficiency scores were higher than those of the control group. HIS hospital management system for medical equipment management has positive clinical application value, can effectively improve the use of medical equipment, it is worth to draw and promote.
Slit Lamp-Based Ocular Scoring Systems in Toxicology and Drug Development: A Literature Survey.
Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J
2017-12-01
To present a survey of the features of published slit lamp-based scoring systems and their applicability in the context of modern ocular toxicology and drug development. References describing original or modified slit lamp-based scoring systems for human or veterinary clinical patients or in investigative or toxicologic research were collected following a comprehensive literature review using textbooks and online publication searches. Each system's indications and features were compiled to facilitate comparison. Literature review identified 138 original or modified scoring systems. Most (48%) were published for evaluation of the ocular surface, 34% for the general anterior segment, and 18% for the lens. Most systems were described for assessment of human patients (50%) and small albino laboratory species such as rabbits (19%), rats (12%), and mice (8%). Systems described for pigmented laboratory species and for larger species such as dogs, cats, pigs, and nonhuman primates (NHPs) were comparatively underrepresented. No systems described a lens scoring scheme specific to the dog, cat, pig, or NHP. Scoring schemes for aqueous and vitreous cells were infrequently described for laboratory species. Many slit lamp-based scoring systems have been published, but the features of each differ and complicate translation of findings between different species. Use and interpretation of any scoring system in toxicology and drug development must be done with awareness of the limitations of the system being used.
A reliable and cost effective approach for radiographic monitoring in nutritional rickets.
Chatterjee, D; Gupta, V; Sharma, V; Sinha, B; Samanta, S
2014-04-01
Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg(-1)) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution.
Scoring systems for outcome prediction in patients with perforated peptic ulcer.
Thorsen, Kenneth; Søreide, Jon Arne; Søreide, Kjetil
2013-04-10
Patients with perforated peptic ulcer (PPU) often present with acute, severe illness that carries a high risk for morbidity and mortality. Mortality ranges from 3-40% and several prognostic scoring systems have been suggested. The aim of this study was to review the available scoring systems for PPU patients, and to assert if there is evidence to prefer one to the other. We searched PubMed for the mesh terms "perforated peptic ulcer", "scoring systems", "risk factors", "outcome prediction", "mortality", "morbidity" and the combinations of these terms. In addition to relevant scores introduced in the past (e.g. Boey score), we included recent studies published between January 2000 and December 2012) that reported on scoring systems for prediction of morbidity and mortality in PPU patients. A total of ten different scoring systems used to predict outcome in PPU patients were identified; the Boey score, the Hacettepe score, the Jabalpur score the peptic ulcer perforation (PULP) score, the ASA score, the Charlson comorbidity index, the sepsis score, the Mannheim Peritonitis Index (MPI), the Acute physiology and chronic health evaluation II (APACHE II), the simplified acute physiology score II (SAPS II), the Mortality probability models II (MPM II), the Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity physical sub-score (POSSUM-phys score). Only four of the scores were specifically constructed for PPU patients. In five studies the accuracy of outcome prediction of different scoring systems was evaluated by receiver operating characteristics curve (ROC) analysis, and the corresponding area under the curve (AUC) among studies compared. Considerable variation in performance both between different scores and between different studies was found, with the lowest and highest AUC reported between 0.63 and 0.98, respectively. While the Boey score and the ASA score are most commonly used to predict outcome for PPU patients, considerable variations in accuracy for outcome prediction were shown. Other scoring systems are hampered by a lack of validation or by their complexity that precludes routine clinical use. While the PULP score seems promising it needs external validation before widespread use.
Harel, Daphna; Hudson, Marie; Iliescu, Alexandra; Baron, Murray; Steele, Russell
2016-08-01
To develop a weighted summary score for the Medsger Disease Severity Scale (DSS) and to compare its measurement properties with those of a summed DSS score and a physician's global assessment (PGA) of severity score in systemic sclerosis (SSc). Data from 875 patients with SSc enrolled in a multisite observational research cohort were extracted from a central database. Item response theory was used to estimate weights for the DSS weighted score. Intraclass correlation coefficients (ICC) and convergent, discriminative, and predictive validity of the 3 summary measures in relation to patient-reported outcomes (PRO) and mortality were compared. Mean PGA was 2.69 (SD 2.16, range 0-10), mean DSS summed score was 8.60 (SD 4.02, range 0-36), and mean DSS weighted score was 8.11 (SD 4.05, range 0-36). ICC were similar for all 3 measures [PGA 6.9%, 95% credible intervals (CrI) 2.1-16.2; DSS summed score 2.5%, 95% CrI 0.4-6.7; DSS weighted score 2.0%, 95% CrI 0.1-5.6]. Convergent and discriminative validity of the 3 measures for PRO were largely similar. In Cox proportional hazards models adjusting for age and sex, the 3 measures had similar predictive ability for mortality (adjusted R(2) 13.9% for PGA, 12.3% for DSS summed score, and 10.7% DSS weighted score). The 3 summary scores appear valid and perform similarly. However, there were some concerns with the weights computed for individual DSS scales, with unexpected low weights attributed to lung, heart, and kidney, leading the PGA to be the preferred measure at this time. Further work refining the DSS could improve the measurement properties of the DSS summary scores.
NASA Astrophysics Data System (ADS)
Christensen, Hannah; Moroz, Irene; Palmer, Tim
2015-04-01
Forecast verification is important across scientific disciplines as it provides a framework for evaluating the performance of a forecasting system. In the atmospheric sciences, probabilistic skill scores are often used for verification as they provide a way of unambiguously ranking the performance of different probabilistic forecasts. In order to be useful, a skill score must be proper -- it must encourage honesty in the forecaster, and reward forecasts which are reliable and which have good resolution. A new score, the Error-spread Score (ES), is proposed which is particularly suitable for evaluation of ensemble forecasts. It is formulated with respect to the moments of the forecast. The ES is confirmed to be a proper score, and is therefore sensitive to both resolution and reliability. The ES is tested on forecasts made using the Lorenz '96 system, and found to be useful for summarising the skill of the forecasts. The European Centre for Medium-Range Weather Forecasts (ECMWF) ensemble prediction system (EPS) is evaluated using the ES. Its performance is compared to a perfect statistical probabilistic forecast -- the ECMWF high resolution deterministic forecast dressed with the observed error distribution. This generates a forecast that is perfectly reliable if considered over all time, but which does not vary from day to day with the predictability of the atmospheric flow. The ES distinguishes between the dynamically reliable EPS forecasts and the statically reliable dressed deterministic forecasts. Other skill scores are tested and found to be comparatively insensitive to this desirable forecast quality. The ES is used to evaluate seasonal range ensemble forecasts made with the ECMWF System 4. The ensemble forecasts are found to be skilful when compared with climatological or persistence forecasts, though this skill is dependent on region and time of year.
Earlam, S; Glover, C; Davies, M; Fordy, C; Allen-Mersh, T G
1997-05-01
Since systemic and regional (HAI) fluorinated pyrimidine chemotherapies offer similar survival benefit in treatment of colorectal liver metastases (CLM), we sought to identify their impact on quality of life (QoL), which might be a useful indicator of treatment preference. We compared QoL in 135 CLM patients managed by symptom control (n = 49 patients), systemic fluorouracil (5FU)/folinic acid (n = 35), or hepatic arterial floxuridine (FUDR) (n = 51). Full blood count and liver function tests, World Health Organization (WHO) toxicity criteria, and QoL (Rotterdam Symptom Checklist [RSC], the Sickness Impact Profile [SIP], and the Hospital Anxiety and Depression scale [HAD]) were measured monthly in all patients. The HAD anxiety score was significantly increased in symptom control compared with chemotherapy patients 1 month after randomization. There was a significant increase in RSC physical score (repeated measures, P = .05), and in scores for sore mouth (P < .01), dry mouth (P < .01), and tingling hands and feet (P < .01) in systemic chemotherapy compared with symptom control patients. Significant QoL differences (repeated measures and Mann-Whitney U [MWU]) between HAI and symptom control patients were not detected. Systemic chemotherapy patients lived for significantly longer (log-rank test, P < or = .0001) with abnormal HAD anxiety, RSC psychosocial, or RSC sore mouth scores compared with HAI patients, but there were no overall survival differences. Randomization to symptom control only was associated with increased anxiety. QoL with systemic chemotherapy was impaired by side effects. HAI was associated with similar survival to systemic chemotherapy but with better sustained QoL.
Commercial Building Energy Asset Score Program Overview and Technical Protocol (Version 1.1)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Goel, Supriya; Makhmalbaf, Atefe
The U.S. Department of Energy (DOE) is developing a voluntary national scoring system for commercial buildings to help building owners and managers assess a building’s energy-related systems independent of operations. The goal of the score is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system, known as the Commercial Building Energy Asset Score, will allow building owners and managers to compare their building infrastructure against peers and track building upgrades over time. The system will also help other building stakeholders (e.g., building investors, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in amore » way that is independent from operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset scoring tool. The alternative methods that were considered prior to developing the current approach are described in the Program Overview and Technical Protocol Version 1.0.« less
Motola-Kuba, Miguel; Escobedo-Arzate, Angélica; Tellez-Avila, Félix; Altamirano, José; Aguilar-Olivos, Nancy; González-Angulo, Alberto; Zamarripa-Dorsey, Felipe; Uribe, Misael; Chávez-Tapia, Norberto C
Background. The Rockall, Glasgow-Blatchford, and AIMS65 are useful and validated scoring systems for predicting the outcomes of patients with nonvariceal gastrointestinal bleeding. However, there are no validated evidence for using them to predict outcomes on variceal bleeding. The aim of this study was to evaluate and compare the prognostic accuracy of different nonvariceal bleeding scores with other liver-specific scoring systems in cirrhotic patients. A retrospective multicenter study that included 160 cirrhotic patients with acute variceal bleeding. The AUROC's to predict in-hospital mortality, and rebleeding, were analyzed for each scoring system. Overall in-hospital mortality occurred in 13% and in-hospital rebleeding in 12% of patients. The systems with the best AUROC value for predicting mortality were MELD (0.828; 95% CI 0.748-0.909), and AIMS65 (0.817; 95% CI 0.724-0.909). The best score systems for predicting rebleeding were Glasgow-Blatchford (0.756; 95% CI 0.640- 0.827), and Rockall (0.691; 95% CI 0.580-0.802). In addition to liver-specific scores, the AIMS65 score is accurate for predicting in-hospital mortality in cirrhotic patients with acute variceal bleeding. Other scoring systems might be useful for predicting significant clinical outcomes in these patients.
A threshold-free summary index of prediction accuracy for censored time to event data.
Yuan, Yan; Zhou, Qian M; Li, Bingying; Cai, Hengrui; Chow, Eric J; Armstrong, Gregory T
2018-05-10
Prediction performance of a risk scoring system needs to be carefully assessed before its adoption in clinical practice. Clinical preventive care often uses risk scores to screen asymptomatic population. The primary clinical interest is to predict the risk of having an event by a prespecified future time t 0 . Accuracy measures such as positive predictive values have been recommended for evaluating the predictive performance. However, for commonly used continuous or ordinal risk score systems, these measures require a subjective cutoff threshold value that dichotomizes the risk scores. The need for a cutoff value created barriers for practitioners and researchers. In this paper, we propose a threshold-free summary index of positive predictive values that accommodates time-dependent event status and competing risks. We develop a nonparametric estimator and provide an inference procedure for comparing this summary measure between 2 risk scores for censored time to event data. We conduct a simulation study to examine the finite-sample performance of the proposed estimation and inference procedures. Lastly, we illustrate the use of this measure on a real data example, comparing 2 risk score systems for predicting heart failure in childhood cancer survivors. Copyright © 2018 John Wiley & Sons, Ltd.
Mainigi, Sumeet K; Chebrolu, Lakshmi Hima Bindu; Romero-Corral, Abel; Mehta, Vinay; Machado, Rodolfo Rozindo; Konecny, Tomas; Pressman, Gregg S
2012-10-01
Cardiac calcification is associated with coronary artery disease, arrhythmias, conduction disease, and adverse cardiac events. Recently, we have described an echocardiographic-based global cardiac calcification scoring system. The objective of this study was to evaluate the severity of cardiac calcification in patients with permanent pacemakers as based on this scoring system. Patients with a pacemaker implanted within the 2-year study period with a previous echocardiogram were identified and underwent blinded global cardiac calcium scoring. These patients were compared to matched control patients without a pacemaker who also underwent calcium scoring. The study group consisted of 49 patients with pacemaker implantation who were compared to 100 matched control patients. The mean calcium score in the pacemaker group was 3.3 ± 2.9 versus 1.8 ± 2.0 (P = 0.006) in the control group. Univariate and multivariate analysis revealed glomerular filtration rate and calcium scoring to be significant predictors of the presence of a pacemaker. Echocardiographic-based calcium scoring correlates with the presence of severe conduction disease requiring a pacemaker. © 2012, Wiley Periodicals, Inc.
Vlad, Violeta; Berghea, Florian; Micu, Mihaela; Varzaru, Luminita; Bojinca, Mihai; Milicescu, Mihaela; Ionescu, Ruxandra; Naredo, Esperanza
2015-09-01
To investigate by ultrasonography (US) in a cohort of active RA patients starting biologic therapy the responsiveness of tenosynovitis of wrist and hands compared to the responsiveness of synovitis in a 6 month period follow-up, to compare the responsiveness of finger flexor tenosynovitis with the responsiveness of wrist extensor tenosynovitis and to describe the subclinical synovitis and tenosynovitis in RA patients in clinical remission. Fifty seven patients with active RA starting biologic therapy were included. Clinical, laboratory, and US evaluations were performed at baseline, 1, and 6 months. US evaluation included wrist and MCPs 2-5 joints, bilaterally for synovitis and extensor tendons compartments 2, 4, and 6 and finger flexors 2-5 for tenosynovitis. Eighteen US scores based on semiquantitative or binary grades were calculated at each visit. Responsiveness of synovitis and tenosynovitis scores was calculated using the standardized response mean (SRM). The responsiveness of US tenosynovitis was lower comparing with the responsiveness of US synovitis but both showed large effect of therapy. Furthermore, tenosynovitis responsiveness was similar to CRP responsiveness (SRM -0.90). Finger flexors tenosynovitis showed a higher responsiveness than extensor tenosynovitis on GS (-0.94 compared to -0.63) and a lower SRM on PD (-0.56 compared to -0.85). Tenosynovitis scores remission was overlapping clinical remission according to CDAI and SDAI in 100% of cases. Overall there was less subclinical tenosynovitis than subclinical synovitis at final visit according to clinical activity indices. Tenosynovitis US scoring in RA may be as good as synovitis scoring for characterization of disease activity and responsiveness.
Uz, Burak; Buyukasik, Yahya; Atay, Hilmi; Kelkitli, Engin; Turgut, Mehmet; Bektas, Ozlen; Eliacik, Eylem; Isik, Ayşe; Aksu, Salih; Goker, Hakan; Sayinalp, Nilgun; Ozcebe, Osman I; Haznedaroglu, Ibrahim C
2013-09-01
The validity of the three currently used chronic myeloid leukemia (CML) scoring systems (Sokal CML prognostic scoring system, Euro/Hasford CML scoring system, and the EUTOS CML prognostic scoring system) were compared in the CML patients receiving frontline imatinib mesylate. One hundred and fourty-three chronic phase CML patients (71 males, 72 females) taking imatinib as frontline treatment were included in the study. The median age was 44 (16-82) years. Median total and on-imatinib follow-up durations were 29 (3.8-130) months and 25 (3-125) months, respectively. The complete hematological response (CHR) rate at 3 months was 95%. The best cumulative complete cytogenetic response (CCyR) rate at 24 months was 79.6%. Euro/Hasford scoring system was well-correlated with both Sokal and EUTOS scores (r = 0.6, P < 0.001 and r = 0.455, P < 0.001). However, there was only a weak correlation between Sokal and EUTOS scores (r = 0.2, P = 0.03). The 5-year median estimated event-free survival for low and high EUTOS risk patients were 62.6 (25.7-99.5) and 15.3 (7.4-23.2) months, respectively (P < 0.001). This performance was better than Sokal (P = 0.3) and Euro/Hasford (P = 0.04) scoring systems. Overall survival and CCyR rates were also better predicted by the EUTOS score. EUTOS CML prognostic scoring system, which is the only prognostic system developed during the imatinib era, predicts European LeukemiaNet (ELN)-based event-free survival better than Euro/Hasford and Sokal systems in CML patients receiving frontline imatinib mesylate. This observation might have important clinical implications.
Developing Conceptions of Authority and Contract across the Lifespan: Two Perspectives.
ERIC Educational Resources Information Center
Dawson, Theo L.; Gabrielian, Sonya
2003-01-01
Compares concepts defining Kohlbergian stages of moral development with those associated with orders of hierarchical complexity determined with a generalized content-independent stage-scoring system. Finds that Kohlberg's sequence generally matches that identified with the scoring system and that contract and authority concepts match the concepts…
Sanders, Sharon; Flaws, Dylan; Than, Martin; Pickering, John W; Doust, Jenny; Glasziou, Paul
2016-01-01
Scoring systems are developed to assist clinicians in making a diagnosis. However, their uptake is often limited because they are cumbersome to use, requiring information on many predictors, or complicated calculations. We examined whether, and how, simplifications affected the performance of a validated score for identifying adults with chest pain in an emergency department who have low risk of major adverse cardiac events. We simplified the Emergency Department Assessment of Chest pain Score (EDACS) by three methods: (1) giving equal weight to each predictor included in the score, (2) reducing the number of predictors, and (3) using both methods--giving equal weight to a reduced number of predictors. The diagnostic accuracy of the simplified scores was compared with the original score in the derivation (n = 1,974) and validation (n = 909) data sets. There was no difference in the overall accuracy of the simplified versions of the score compared with the original EDACS as measured by the area under the receiver operating characteristic curve (0.74 to 0.75 for simplified versions vs. 0.75 for the original score in the validation cohort). With score cut-offs set to maintain the sensitivity of the combination of score and tests (electrocardiogram and cardiac troponin) at a level acceptable to clinicians (99%), simplification reduced the proportion of patients classified as low risk from 50% with the original score to between 22% and 42%. Simplification of a clinical score resulted in similar overall accuracy but reduced the proportion classified as low risk and therefore eligible for early discharge compared with the original score. Whether the trade-off is acceptable, will depend on the context in which the score is to be used. Developers of clinical scores should consider simplification as a method to increase uptake, but further studies are needed to determine the best methods of deriving and evaluating simplified scores. Copyright © 2016 Elsevier Inc. All rights reserved.
Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition
Islam, Md. Rabiul
2014-01-01
The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al. PMID:25114676
Feature and score fusion based multiple classifier selection for iris recognition.
Islam, Md Rabiul
2014-01-01
The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.
Fakih, Mohamad G; Skierczynski, Boguslow; Bufalino, Angelo; Groves, Clariecia; Roberts, Phillip; Heavens, Michelle; Hendrich, Ann; Haydar, Ziad
2016-12-01
The standardized infection ratio (SIR) evaluates individual publicly reported health care-associated infections, but it may not assess overall performance. We piloted an infection composite score (ICS) in 82 hospitals of a single health system. The ICS is a combined score for central line-associated bloodstream infections, catheter-associated urinary tract infections, colon and abdominal hysterectomy surgical site infections, and hospital-onset methicillin-resistant Staphylococcus aureus bacteremia and Clostridium difficile infections. Individual facility ICSs were calculated by normalizing each of the 6 SIR events to the system SIR for baseline and performance periods (ICS ib and ICS ip , respectively). A hospital ICS ib reflected its baseline performance compared with system baseline, whereas a ICS ip provided information of its outcome changes compared with system baseline. Both the ICS ib (baseline 2013) and ICS ip (performance 2014) were calculated for 63 hospitals (reporting at least 4 of the 6 event types). The ICS ip improved in 36 of 63 (57.1%) hospitals in 2014 when compared with the ICS ib in 2013. The ICS ib 2013 median was 0.96 (range, 0.13-2.94) versus the 2014 ICS ip median of 0.92 (range, 0-6.55). Variation was more evident in hospitals with ≤100 beds. The system performance score (ICS sp ) in 2014 was 0.95, a 5% improvement compared with 2013. The proposed ICS may help large health systems and state hospital associations better evaluate key infectious outcomes, comparing them with historic and concurrent performance of peers. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Iwata, Shintaro; Uehara, Kosuke; Ogura, Koichi; Akiyama, Toru; Shinoda, Yusuke; Yonemoto, Tsukasa; Kawai, Akira
2016-09-01
The Musculoskeletal Tumor Society (MSTS) scoring system is a widely used functional evaluation tool for patients treated for musculoskeletal tumors. Although the MSTS scoring system has been validated in English and Brazilian Portuguese, a Japanese version of the MSTS scoring system has not yet been validated. We sought to determine whether a Japanese-language translation of the MSTS scoring system for the lower extremity had (1) sufficient reliability and internal consistency, (2) adequate construct validity, and (3) reasonable criterion validity compared with the Toronto Extremity Salvage Score (TESS) and SF-36 using psychometric analysis. The Japanese version of the MSTS scoring system was developed using accepted guidelines, which included translation of the English version of the MSTS into Japanese by five native Japanese bilingual musculoskeletal oncology surgeons and integrated into one document. One hundred patients with a diagnosis of intermediate or malignant bone or soft tissue tumors located in the lower extremity and who had undergone tumor resection with or without reconstruction or amputation participated in this study. Reliability was evaluated by test-retest analysis, and internal consistency was established by Cronbach's alpha coefficient. Construct validity was evaluated using the principal factor analysis and Akaike information criterion network. Criterion validity was evaluated by comparing the MSTS scoring system with the TESS and SF-36. Test-retest analysis showed a high intraclass correlation coefficient (0.92; 95% CI, 0.88-0.95), indicating high reliability of the Japanese version of the MSTS scoring system, although a considerable ceiling effect was observed, with 23 patients (23%) given the maximum score. Cronbach's alpha coefficient was 0.87 (95% CI, 0.82-0.90), suggesting a high level of internal consistency. Factor analysis revealed that all items had high loading values and communalities; we identified a central role for the items "walking" and "gait" according to the Akaike information criterion network. The total MSTS score was correlated with that of the TESS (r = 0.81; 95% CI, 0.73-0.87; p < 0.001) and the physical component summary and physical functioning of the SF-36. The Japanese-language translation of the MSTS scoring system for the lower extremity has sufficient reliability and reasonable validity. Nevertheless, the observation of a ceiling effect suggests poor ability of this system to discriminate from among patients who have a high level of function.
A Risk Score Model for Evaluation and Management of Patients with Thyroid Nodules.
Zhang, Yongwen; Meng, Fanrong; Hong, Lianqing; Chu, Lanfang
2018-06-12
The study is aimed to establish a simplified and practical tool for analyzing thyroid nodules. A novel risk score model was designed, risk factors including patient history, patient characteristics, physical examination, symptoms of compression, thyroid function, ultrasonography (US) of thyroid and cervical lymph nodes were evaluated and classified into high risk factors, intermediate risk factors, and low risk factors. A total of 243 thyroid nodules in 162 patients were assessed with risk score system and Thyroid Imaging-Reporting and Data System (TI-RADS). The diagnostic performance of risk score system and TI-RADS was compared. The accuracy in the diagnosis of thyroid nodules was 89.3% for risk score system, 74.9% for TI-RADS respectively. The specificity, accuracy and positive predictive value (PPV) of risk score system were significantly higher than the TI-RADS system (χ 2 =26.287, 17.151, 11.983; p <0.05), statistically significant differences were not observed in the sensitivity and negative predictive value (NPV) between the risk score system and TI-RADS (χ 2 =1.276, 0.290; p>0.05). The area under the curve (AUC) for risk score diagnosis system was 0.963, standard error 0.014, 95% confidence interval (CI)=0.934-0.991, the AUC for TI-RADS diagnosis system was 0.912 with standard error 0.021, 95% CI=0.871-0.953, the AUC for risk score system was significantly different from that of TI-RADS (Z=2.02; p <0.05). Risk score model is a reliable, simplified and cost-effective diagnostic tool used in diagnosis of thyroid cancer. The higher the score is, the higher the risk of malignancy will be. © Georg Thieme Verlag KG Stuttgart · New York.
Additional Support for the Information Systems Analyst Exam as a Valid Program Assessment Tool
ERIC Educational Resources Information Center
Carpenter, Donald A.; Snyder, Johnny; Slauson, Gayla Jo; Bridge, Morgan K.
2011-01-01
This paper presents a statistical analysis to support the notion that the Information Systems Analyst (ISA) exam can be used as a program assessment tool in addition to measuring student performance. It compares ISA exam scores earned by students in one particular Computer Information Systems program with scores earned by the same students on the…
Scoring systems for outcome prediction in patients with perforated peptic ulcer
2013-01-01
Background Patients with perforated peptic ulcer (PPU) often present with acute, severe illness that carries a high risk for morbidity and mortality. Mortality ranges from 3-40% and several prognostic scoring systems have been suggested. The aim of this study was to review the available scoring systems for PPU patients, and to assert if there is evidence to prefer one to the other. Material and methods We searched PubMed for the mesh terms “perforated peptic ulcer”, “scoring systems”, “risk factors”, ”outcome prediction”, “mortality”, ”morbidity” and the combinations of these terms. In addition to relevant scores introduced in the past (e.g. Boey score), we included recent studies published between January 2000 and December 2012) that reported on scoring systems for prediction of morbidity and mortality in PPU patients. Results A total of ten different scoring systems used to predict outcome in PPU patients were identified; the Boey score, the Hacettepe score, the Jabalpur score the peptic ulcer perforation (PULP) score, the ASA score, the Charlson comorbidity index, the sepsis score, the Mannheim Peritonitis Index (MPI), the Acute physiology and chronic health evaluation II (APACHE II), the simplified acute physiology score II (SAPS II), the Mortality probability models II (MPM II), the Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity physical sub-score (POSSUM-phys score). Only four of the scores were specifically constructed for PPU patients. In five studies the accuracy of outcome prediction of different scoring systems was evaluated by receiver operating characteristics curve (ROC) analysis, and the corresponding area under the curve (AUC) among studies compared. Considerable variation in performance both between different scores and between different studies was found, with the lowest and highest AUC reported between 0.63 and 0.98, respectively. Conclusion While the Boey score and the ASA score are most commonly used to predict outcome for PPU patients, considerable variations in accuracy for outcome prediction were shown. Other scoring systems are hampered by a lack of validation or by their complexity that precludes routine clinical use. While the PULP score seems promising it needs external validation before widespread use. PMID:23574922
Clements, Julie; Sanchez, Jessica N
2015-11-01
This research aims to validate a novel, visual body scoring system created for the Magellanic penguin (Spheniscus magellanicus) suitable for the zoo practitioner. Magellanics go through marked seasonal fluctuations in body mass gains and losses. A standardized multi-variable visual body condition guide may provide a more sensitive and objective assessment tool compared to the previously used single variable method. Accurate body condition scores paired with seasonal weight variation measurements give veterinary and keeper staff a clearer understanding of an individual's nutritional status. San Francisco Zoo staff previously used a nine-point body condition scale based on the classic bird standard of a single point of keel palpation with the bird restrained in hand, with no standard measure of reference assigned to each scoring category. We created a novel, visual body condition scoring system that does not require restraint to assesses subcutaneous fat and muscle at seven body landmarks using illustrations and descriptive terms. The scores range from one, the least robust or under-conditioned, to five, the most robust, or over-conditioned. The ratio of body weight to wing length was used as a "gold standard" index of body condition and compared to both the novel multi-variable and previously used single-variable body condition scores. The novel multi-variable scale showed improved agreement with weight:wing ratio compared to the single-variable scale, demonstrating greater accuracy, and reliability when a trained assessor uses the multi-variable body condition scoring system. Zoo staff may use this tool to manage both the colony and the individual to assist in seasonally appropriate Magellanic penguin nutrition assessment. © 2015 Wiley Periodicals, Inc.
Locus of Control as a Measure of Ineffectiveness in Anorexia Nervosa.
ERIC Educational Resources Information Center
Hood, Jane; And Others
1982-01-01
Using a multidimensional locus of control scale, scores of female anorexia nervosa patients (N=54) were compared to norms. Younger anorexic patients demonstrated higher internal control compared to norms on times related to fatalism and social-system control. Scores for older patients could not be differentiated from the norms. (Author)
Validation of the modified Ranson versus Glasgow score for pancreatitis in a Singaporean population.
Tan, Yong Hui Alvin; Rafi, Shumaila; Tyebally Fang, Mirriam; Hwang, Stephen; Lim, Ee Wen; Ngu, James; Tan, Su-Ming
2017-09-01
The characteristics of patients with acute pancreatitis in multi-ethnic Singapore differ from that of the populations used in formulating the modified Ranson and Glasgow scores. The use of these scoring systems has not previously been validated in the Singaporean setting. This study aims to validate and compare the prognostic use of the modified Ranson and Glasgow scores, and to determine the superiority of one score over the other in predicting the outcome for acute pancreatitis in the Singaporean population. This is a 3-year retrospective study of patients diagnosed with acute pancreatitis at our centre. Patients with chronic pancreatitis, acute on chronic pancreatitis, iatrogenic pancreatitis, pancreatic cancer as well as those with incomplete Ranson or Glasgow scores were excluded from the study. Case notes and computer records were reviewed for local complications of pancreatitis and organ failure. Receiver operator characteristic (ROC) curves of the Ranson and Glasgow scores were plotted for the prediction of severity and mortality. Between January 2010 and December 2012, 230 cases were diagnosed with acute pancreatitis. A majority of the patients had mild pancreatitis (n = 194, 84.3%), and the overall 30-day mortality rate was 3.5% (n = 8). ROC of the Ranson and Glasgow scoring systems for mortality showed an area under curve (AUC) of 0.854 (P = 0.001) and 0.776 (P = 0.008), respectively. For severity, the AUC for the modified Ranson and Glasgow score was calculated to be 0.694 and 0.668, respectively. The ROC curves of Ranson and Glasgow scores for mortality are comparable with that published in earlier studies. In a Singaporean population, the Ranson score is more accurate in the prediction of mortality. However, both scoring systems are poor predictors for severity of acute pancreatitis. © 2015 Royal Australasian College of Surgeons.
Fedakar, Recep; Aydiner, Ahmet Hüsamettin; Ercan, Ilker
2007-07-01
To compare accuracy and to check the suitability of the Glasgow Coma Scale (GCS), the Revised Trauma Score (RTS), the Injury Severity Score (ISS), the New Injury Severity Score (NISS) and the Trauma and Injury Severity Score (TRISS), the scoring systems widely used in international trauma studies, in the evaluation of the "life threatening injury" concept established by the Turkish Penal Code. The age, sex, type of trauma, type and localizations of wounds, GCS, RTS, ISS, NISS and TRISS values, the decision of life threatening injury of 627 trauma patients admitted to Emergency Department of the Uludag University Medical School Hospital in year 2003 were examined. A life-threatening injury was present in 35.2% of the cases examined. GCS, RTS, ISS, NISS and TRISS confirmed the decision of life threatening injury with percentages of 74.8%, 76.9%, 88.7%, 86.6% and 68.6%, respectively. The best cut-off point 14 was determined in the ISS system with 79.6% sensitivity and 93.6% specificity. All of the cases with sole linear skull fracture officially decided as life threatening injury had an ISS of 5, a NISS of 6 and the best scores of GCS (15), RTS (7.8408) and TRISS (100%). ISS and NISS appeared to be the best trauma scoring systems that can be used for the decision of life threatening injury, compared with GCS, RTS and TRISS. Thus, ISS and NISS can be acceptable for using the evaluation of the life threatening injury concept established by the Turkish Penal Code.
Azad, Aftab Mohammad; Al Juma, Saad; Bhatti, Junaid Ahmad; Delaney, J Scott
2016-01-01
Balance testing is an important part of the initial concussion assessment. There is no research on the differences in Modified Balance Error Scoring System (M-BESS) scores when tested in real world as compared to control conditions. To assess the difference in M-BESS scores in athletes wearing their protective equipment and cleats on different surfaces as compared to control conditions. This cross-sectional study examined university North American football and soccer athletes. Three observers independently rated athletes performing the M-BESS test in three different conditions: (1) wearing shorts and T-shirt in bare feet on firm surface (control); (2) wearing athletic equipment with cleats on FieldTurf; and (3) wearing athletic equipment with cleats on firm surface. Mean M-BESS scores were compared between conditions. 60 participants were recruited: 39 from football (all males) and 21 from soccer (11 males and 10 females). Average age was 21.1 years (SD=1.8). Mean M-BESS scores were significantly lower (p<0.001) for cleats on FieldTurf (mean=26.3; SD=2.0) and for cleats on firm surface (mean=26.6; SD=2.1) as compared to the control condition (mean=28.4; SD=1.5). Females had lower scores than males for cleats on FieldTurf condition (24.9 (SD=1.9) vs 27.3 (SD=1.6), p=0.005). Players who had taping or bracing on their ankles/feet had lower scores when tested with cleats on firm surface condition (24.6 (SD=1.7) vs 26.9 (SD=2.0), p=0.002). Total M-BESS scores for athletes wearing protective equipment and cleats standing on FieldTurf or a firm surface are around two points lower than M-BESS scores performed on the same athletes under control conditions.
Azad, Aftab Mohammad; Al Juma, Saad; Bhatti, Junaid Ahmad; Delaney, J Scott
2016-01-01
Background Balance testing is an important part of the initial concussion assessment. There is no research on the differences in Modified Balance Error Scoring System (M-BESS) scores when tested in real world as compared to control conditions. Objective To assess the difference in M-BESS scores in athletes wearing their protective equipment and cleats on different surfaces as compared to control conditions. Methods This cross-sectional study examined university North American football and soccer athletes. Three observers independently rated athletes performing the M-BESS test in three different conditions: (1) wearing shorts and T-shirt in bare feet on firm surface (control); (2) wearing athletic equipment with cleats on FieldTurf; and (3) wearing athletic equipment with cleats on firm surface. Mean M-BESS scores were compared between conditions. Results 60 participants were recruited: 39 from football (all males) and 21 from soccer (11 males and 10 females). Average age was 21.1 years (SD=1.8). Mean M-BESS scores were significantly lower (p<0.001) for cleats on FieldTurf (mean=26.3; SD=2.0) and for cleats on firm surface (mean=26.6; SD=2.1) as compared to the control condition (mean=28.4; SD=1.5). Females had lower scores than males for cleats on FieldTurf condition (24.9 (SD=1.9) vs 27.3 (SD=1.6), p=0.005). Players who had taping or bracing on their ankles/feet had lower scores when tested with cleats on firm surface condition (24.6 (SD=1.7) vs 26.9 (SD=2.0), p=0.002). Conclusions Total M-BESS scores for athletes wearing protective equipment and cleats standing on FieldTurf or a firm surface are around two points lower than M-BESS scores performed on the same athletes under control conditions. PMID:27900181
Review article: scoring systems for assessing prognosis in critically ill adult cirrhotics.
Cholongitas, E; Senzolo, M; Patch, D; Shaw, S; Hui, C; Burroughs, A K
2006-08-01
Cirrhotic patients admitted to intensive care units (ICU) still have poor outcomes. Some current ICU prognostic models [Acute Physiology and Chronic Health Evaluation (APACHE), Organ System Failure (OSF) and Sequential Organ Failure Assessment (SOFA)] were used to stratify cirrhotics into risk categories, but few cirrhotics were included in the original model development. Liver-specific scores [Child-Turcotte-Pugh (CTP) and model for end-stage liver disease (MELD)] could be useful in this setting. To evaluate whether ICU prognostic models perform better compared with liver-disease specific ones in cirrhotics admitted to ICU. We performed a structured literature review identifying clinical studies focusing on prognosis and risk factors for mortality in adult cirrhotics admitted to ICU. We found 21 studies (five solely dealing with gastrointestinal bleeding) published during the last 20 years (54-420 patients in each). APACHE II and III, SOFA and OSF had better discrimination for correctly predicting death compared with the CTP score. The MELD score was evaluated only in one study and had good predictive accuracy [receiver operator characteristic (ROC) curve: 0.81). Organ dysfunction models (OSF, SOFA) were superior compared with APACHE II and III (ROC curve: range 0.83-0.94 vs. 0.66-0.88 respectively). Cardiovascular, liver and renal system dysfunction were more frequently independently associated with mortality. General-ICU models had better performance in cirrhotic populations compared with CTP score; OSF and SOFA had the best predictive ability. Further prospective and validation studies are needed.
A reliable and cost effective approach for radiographic monitoring in nutritional rickets
Gupta, V; Sharma, V; Sinha, B; Samanta, S
2014-01-01
Objective: Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. Methods: 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg−1) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Results: Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Conclusion: Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. Advances in knowledge: The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution. PMID:24593231
Donahoe, Laura; McDonald, Ellen; Kho, Michelle E; Maclennan, Margaret; Stratford, Paul W; Cook, Deborah J
2009-01-01
Given their clinical, research, and administrative purposes, scores on the Acute Physiology and Chronic Health Evaluation (APACHE) II should be reliable, whether calculated by health care personnel or a clinical information system. To determine reliability of APACHE II scores calculated by a clinical information system and by health care personnel before and after a multifaceted quality improvement intervention. APACHE II scores of 37 consecutive patients admitted to a closed, 15-bed, university-affiliated intensive care unit were collected by a research coordinator, a database clerk, and a clinical information system. After a quality improvement intervention focused on health care personnel and the clinical information system, the same methods were used to collect data on 32 consecutive patients. The research coordinator and the clerk did not know each other's scores or the information system's score. The data analyst did not know the source of the scores until analysis was complete. APACHE II scores obtained by the clerk and the research coordinator were highly reliable (intraclass correlation coefficient, 0.88 before vs 0.80 after intervention; P = .25). No significant changes were detected after the intervention; however, compared with scores of the research coordinator, the overall reliability of APACHE II scores calculated by the clinical information system improved (intraclass correlation coefficient, 0.24 before intervention vs 0.91 after intervention, P < .001). After completion of a quality improvement intervention, health care personnel and a computerized clinical information system calculated sufficiently reliable APACHE II scores for clinical, research, and administrative purposes.
Hwang, Hee Sang; Yoon, Dok Hyun; Suh, Cheolwon; Huh, Jooryung
2016-08-01
Extranodal involvement is a well-known prognostic factor in patients with diffuse large B-cell lymphomas (DLBCL). Nevertheless, the prognostic impact of the extranodal scoring system included in the conventional international prognostic index (IPI) has been questioned in an era where rituximab treatment has become widespread. We investigated the prognostic impacts of individual sites of extranodal involvement in 761 patients with DLBCL who received rituximab-based chemoimmunotherapy. Subsequently, we established a new extranodal scoring system based on extranodal sites, showing significant prognostic correlation, and compared this system with conventional scoring systems, such as the IPI and the National Comprehensive Cancer Network-IPI (NCCN-IPI). An internal validation procedure, using bootstrapped samples, was also performed for both univariate and multivariate models. Using multivariate analysis with a backward variable selection, we found nine extranodal sites (the liver, lung, spleen, central nervous system, bone marrow, kidney, skin, adrenal glands, and peritoneum) that remained significant for use in the final model. Our newly established extranodal scoring system, based on these sites, was better correlated with patient survival than standard scoring systems, such as the IPI and the NCCN-IPI. Internal validation by bootstrapping demonstrated an improvement in model performance of our modified extranodal scoring system. Our new extranodal scoring system, based on the prognostically relevant sites, may improve the performance of conventional prognostic models of DLBCL in the rituximab era and warrants further external validation using large study populations.
Buxbaum, James; Quezada, Michael; Chong, Bradford; Gupta, Nikhil; Yu, Chung Yao; Lane, Christianne; Da, Ben; Leung, Kenneth; Shulman, Ira; Pandol, Stephen; Wu, Bechien
2018-05-01
The Pancreatitis Activity Scoring System (PASS) has been derived by an international group of experts via a modified Delphi process. Our aim was to perform an external validation study to assess for concordance of the PASS score with high face validity clinical outcomes and determine specific meaningful thresholds to assist in application of this scoring system in a large prospectively ascertained cohort. We analyzed data from a prospective cohort study of consecutive patients admitted to the Los Angeles County Hospital between March 2015 and March 2017. Patients were identified using an emergency department paging system and electronic alert system. Comprehensive characterization included substance use history, pancreatitis etiology, biochemical profile, and detailed clinical course. We calculated the PASS score at admission, discharge, and at 12 h increments during the hospitalization. We performed several analyses to assess the relationship between the PASS score and outcomes at various points during hospitalization as well as following discharge. Using multivariable logistic regression analysis, we assessed the relationship between admission PASS score and risk of severe pancreatitis. PASS score performance was compared to established systems used to predict severe pancreatitis. Additional inpatient outcomes assessed included local complications, length of stay, development of systemic inflammatory response syndrome (SIRS), and intensive care unit (ICU) admission. We also assessed whether the PASS score at discharge was associated with early readmission (re-hospitalization for pancreatitis symptoms and complications within 30 days of discharge). A total of 439 patients were enrolled, their mean age was 42 (±15) years, and 53% were male. Admission PASS score >140 was associated with moderately severe and severe pancreatitis (OR 3.5 [95% CI 2.0, 6.3]), ICU admission (OR 4.9 [2.5, 9.4]), local complications (3.0 [1.6, 5.7]), and development of SIRS (OR 2.9 [1.8, 4.5]) as well as prolongation of hospitalization by a mean of 1.5 (1.3-1.7) days. For the prediction of moderately severe/severe pancreatitis, the PASS score (AUC = 0.71) was comparable to the more established Ranson's (AUC = 0.63), Glasgow (AUC = 0.72), Panc3 (AUC = 0.57), and HAPS (AUC = 0.54) scoring systems. Discharge PASS score >60 was associated with early readmission (OR 5.0 [2.4, 10.7]). The PASS score is associated with important clinical outcomes in acute pancreatitis. The ability of the score to forecast important clinical events at different points in the disease course suggests that it is a valid measure of activity in patients with acute pancreatitis.
Panzer, Stephanie; Mc Coy, Mark R; Hitzl, Wolfgang; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zink, Albert R; Augat, Peter
2015-01-01
The purpose of this study was to develop a checklist for standardized assessment of soft tissue preservation in human mummies based on whole-body computed tomography examinations, and to add a scoring system to facilitate quantitative comparison of mummies. Computed tomography examinations of 23 mummies from the Capuchin Catacombs of Palermo, Sicily (17 adults, 6 children; 17 anthropogenically and 6 naturally mummified) and 7 mummies from the crypt of the Dominican Church of the Holy Spirit of Vilnius, Lithuania (5 adults, 2 children; all naturally mummified) were used to develop the checklist following previously published guidelines. The scoring system was developed by assigning equal scores for checkpoints with equivalent quality. The checklist was evaluated by intra- and inter-observer reliability. The finalized checklist was applied to compare the groups of anthropogenically and naturally mummified bodies. The finalized checklist contains 97 checkpoints and was divided into two main categories, "A. Soft Tissues of Head and Musculoskeletal System" and "B. Organs and Organ Systems", each including various subcategories. The complete checklist had an intra-observer reliability of 98% and an inter-observer reliability of 93%. Statistical comparison revealed significantly higher values in anthropogenically compared to naturally mummified bodies for the total score and for three subcategories. In conclusion, the developed checklist allows for a standardized assessment and documentation of soft tissue preservation in whole-body computed tomography examinations of human mummies. The scoring system facilitates a quantitative comparison of the soft tissue preservation status between single mummies or mummy collections.
Barber, Joy L; Zambrano-Perez, Alexsandra; Olsen, Øystein E; Kiparissi, Fevronia; Baycheva, Mila; Knaflez, Daniela; Shah, Neil; Watson, Tom A
2018-06-01
Magnetic resonance enterography (MRE) is the current gold standard for imaging in inflammatory bowel disease, but ultrasound (US) is a potential alternative. To determine whether US is as good as MRE for the detecting inflamed bowel, using a combined consensus score as the reference standard. We conducted a retrospective cohort study in children and adolescents <18 years with inflammatory bowel disease (IBD) at a tertiary and quaternary centre. We included children who underwent MRE and US within 4 weeks. We scored MRE using the London score and US using a score adapted from the METRIC (MR Enterography or Ultrasound in Crohn's Disease) trial. Four gastroenterologists assessed an independent clinical consensus score. A combined consensus score using the imaging and clinical scores was agreed upon and used as the reference standard to compare MRE with US. We included 53 children. At a whole-patient level, MRE scores were 2% higher than US scores. We used Lin coefficient to assess inter-observer variability. The repeatability of MRE scores was poor (Lin 0.6). Agreement for US scoring was substantial (Lin 0.95). There was a significant positive correlation between MRE and clinical consensus scores (Spearman's rho = 0.598, P=0.0053) and US and clinical consensus scores (Spearman's rho = 0.657, P=0.0016). US detects as much clinically significant bowel disease as MRE. It is possible that MRE overestimates the presence of disease when using a scoring system. This study demonstrates the feasibility of using a clinical consensus reference standard in paediatric IBD imaging studies.
Comparative performances of staging systems for early hepatocellular carcinoma.
Nathan, Hari; Mentha, Gilles; Marques, Hugo P; Capussotti, Lorenzo; Majno, Pietro; Aldrighetti, Luca; Pulitano, Carlo; Rubbia-Brandt, Laura; Russolillo, Nadia; Philosophe, Benjamin; Barroso, Eduardo; Ferrero, Alessandro; Schulick, Richard D; Choti, Michael A; Pawlik, Timothy M
2009-08-01
Several staging systems for patients with hepatocellular carcinoma (HCC) have been proposed, but studies of their prognostic accuracy have yielded conflicting conclusions. Stratifying patients with early HCC is of particular interest because these patients may derive the greatest benefit from intervention, yet no studies have evaluated the comparative performances of staging systems in patients with early HCC. A retrospective cohort study was performed using data on 379 patients who underwent liver resection or liver transplantation for HCC at six major hepatobiliary centres in the USA and Europe. The staging systems evaluated were: the Okuda staging system, the International Hepato-Pancreato-Biliary Association (IHPBA) staging system, the Cancer of the Liver Italian Programme (CLIP) score, the Barcelona Clinic Liver Cancer (BCLC) staging system, the Japanese Integrated Staging (JIS) score and the American Joint Committee on Cancer/International Union Against Cancer (AJCC/UICC) staging system, 6th edition. A recently proposed early HCC prognostic score was also evaluated. The discriminative abilities of the staging systems were evaluated using Cox proportional hazards models and the bootstrap-corrected concordance index (c). Overall survival of the cohort was 74% at 3 years and 52% at 5 years, with a median survival of 62 months. Most systems demonstrated poor discriminatory ability (P > 0.05 on Cox proportional hazards analysis, c approximately 0.5). However, the AJCC/UICC system clearly stratified patients (P < 0.001, c = 0.59), albeit only into two groups. The early HCC prognostic score also clearly stratified patients (P < 0.001, c = 0.60) and identified three distinct prognostic groups. The early HCC prognostic score is superior to the AJCC/UICC staging system (6th edition) for predicting the survival of patients with early HCC after liver resection or liver transplantation. Other major HCC staging systems perform poorly in patients with early HCC.
Shan, Lingtong; Ge, Wen; Pu, Yiwei; Cheng, Hong; Cang, Zhengqiang; Zhang, Xing; Li, Qifan; Xu, Anyang; Wang, Qi; Gu, Chang; Zhang, Yangyang
2018-01-01
To assess and compare the predictive ability of three risk evaluation systems (SinoSCORE, EuroSCORE II and the STS risk evaluation system) in patients aged ≥70, and who underwent coronary artery bypass grafting (CABG) in East China. Three risk evaluation systems were applied to 1,946 consecutive patients who underwent isolated CABG from January 2004 to September 2016 in two hospitals. Patients were divided into two subsets according to their age: elderly group (age ≥70) with a younger group (age <70) used for comparison. The outcome of interest in this study was in-hospital mortality. The entire cohort and subsets of patients were analyzed. The calibration and discrimination in total and in subsets were assessed by the Hosmer-Lemeshow and the C statistics respectively. Institutional overall mortality was 2.52%. The expected mortality rates of SinoSCORE, EuroSCORE II and the STS risk evaluation system were 0.78(0.64)%, 1.43(1.14)% and 0.78(0.77)%, respectively. SinoSCORE achieved the best discrimination (the area under the receiver operating characteristic curve (AUC) = 0.829), followed by the STS risk evaluation system (AUC = 0.790) and EuroSCORE II (AUC = 0.769) in the entire cohort. In the elderly group, the observed mortality rate was 4.82% while it was 1.38% in the younger group. SinoSCORE (AUC = .829) also achieved the best discrimination in the elderly group, followed by the STS risk evaluation system (AUC = .730) and EuroSCORE II (AUC = 0.640) while all three risk evaluation systems all had good performances in the younger group. SinoSCORE, EuroSCORE II and the STS risk evaluation system all achieved positive calibrations in the entire cohort and subsets. The performance of the three risk evaluation systems was not ideal in the entire cohort. In the elderly group, SinoSCORE appeared to achieve better predictive efficiency than EuroSCORE II and the STS risk evaluation system.
Prognostic factors and scoring system for survival in colonic perforation.
Komatsu, Shuhei; Shimomatsuya, Takumi; Nakajima, Masayuki; Amaya, Hirokazu; Kobuchi, Taketsune; Shiraishi, Susumu; Konishi, Sayuri; Ono, Susumu; Maruhashi, Kazuhiro
2005-01-01
No ideal and generally accepted prognostic factors and scoring systems exist to determine the prognosis of peritonitis associated with colonic perforation. This study was designed to investigate prognostic factors and evaluate the various scoring systems to allow identification of high-risk patients. Between 1996 and 2003, excluding iatrogenic and trauma cases, 26 consecutive patients underwent emergency operations for colorectal perforation and were selected for this retrospective study. Several clinical factors were analyzed as possible predictive factors, and APACHE II, SOFA, MPI, and MOF scores were calculated. The overall mortality was 26.9%. Compared with the survivors, non-survivors were found more frequently in Hinchey's stage III-IV, a low preoperative marker of pH, base excess (BE), and a low postoperative marker of white blood cell count, PaO2/FiO2 ratio, and renal output (24h). According to the logistic regression model, BE was a significant independent variable. Concerning the prognostic scoring systems, an APACHE II score of 19, a SOFA score of 8, an MPI score of 30, and an MOF score of 7 or more were significantly related to poor prognosis. Preoperative BE and postoperative white blood cell count were reliable prognostic factors and early classification using prognostic scoring systems at specific points in the disease process are useful to improve our understanding of the problems involved.
Examining Classification Criteria: A Comparison of Three Cut Score Methods
ERIC Educational Resources Information Center
DiStefano, Christine; Morgan, Grant
2011-01-01
This study compared 3 different methods of creating cut scores for a screening instrument, T scores, receiver operating characteristic curve (ROC) analysis, and the Rasch rating scale method (RSM), for use with the Behavioral and Emotional Screening System (BESS) Teacher Rating Scale for Children and Adolescents (Kamphaus & Reynolds, 2007).…
ERIC Educational Resources Information Center
Green, Anthony
2007-01-01
This study investigated whether dedicated test preparation classes gave learners an advantage in improving their writing test scores. Score gains following instruction on a measure of academic writing skills--the International English Language Testing System (IELTS) academic writing test--were compared across language courses of three types; all…
Signal amplification of FISH for automated detection using image cytometry.
Truong, K; Boenders, J; Maciorowski, Z; Vielh, P; Dutrillaux, B; Malfoy, B; Bourgeois, C A
1997-05-01
The purpose of this study was to improve the detection of FISH signals, in order that spot counting by a fully automated image cytometer be comparable to that obtained visually under the microscope. Two systems of spot scoring, visual and automated counting, were investigated in parallel on stimulated human lymphocytes with FISH using a biotinylated centromeric probe for chromosome 3. Signal characteristics were first analyzed on images recorded with a coupled charge device (CCD) camera. Number of spots per nucleus were scored visually on these recorded images versus automatically with a DISCOVERY image analyzer. Several fluochromes, amplification and pretreatments were tested. Our results for both visual and automated scoring show that the tyramide amplification system (TSA) gives the best amplification of signal if pepsin treatment is applied prior to FISH. Accuracy of the automated scoring, however, remained low (58% of nuclei containing two spots) compared to the visual scoring because of the high intranuclear variation between FISH spots.
Greenfield, Julia; Hudson, Marie; Vinet, Evelyne; Fortin, Paul R.; Bykerk, Vivian; Pineau, Christian A.; Wang, Mianbo; Bernatsky, Sasha; Baron, Murray
2017-01-01
Objectives To compare physical and mental health-related quality of life (HRQoL) across four systemic autoimmune rheumatic diseases (SARD). Methods Incident subjects enrolled in four SARD cohorts, namely systemic lupus erythematosus (SLE), systemic sclerosis (SSc), rheumatoid arthritis (RA) and idiopathic inflammatory myopathies (IIM) were studied. The outcomes of interest were baseline Short Form Health Survey physical (PCS) and mental (MCS) component summary scores. Multivariate analysis was conducted to determine whether PCS and MCS scores differed across SARD type. Results The study included 118 SLE (93% women, mean age 36 years), 108 SSc (79% women, mean age 55), 64 RA (63% women, mean age 58) and 25 IIM (68% women, mean age 49) subjects. Mean PCS scores were 38.9 ± 12.2 in SLE, 37.1 ± 13.3 in RA, 35.0 ± 13.6 in SSc and 28.0 ± 15.4 in IIM. Mean MCS scores were 45.0 ± 13.3 in RA, 44.4 ± 14.7 in SSc, 40.1 ± 14.3 in SLE and 33.6 ± 18.7 in IIM. SARD type was an independent predictor of HRQoL with, in some cases, the magnitude of the differences reaching one standard deviation (IIM worse PCS scores compared to SLE (β -12.23 [95% CI -18.11, -6.36; p<0.001]); IIM worse MCS scores compared to SSc (β -11.05 [95% CI -17.53, -4.58; p = 0.001]) and RA (β -11.72 [95% CI -18.62, -4.81; p = 0.001]). Conclusions Cross-SARD research provides a novel approach to gain greater understanding of commonalities and differences across rheumatic diseases. The differences observed warrant further research into correlates and trajectories over time. PMID:29261752
Cook, Heather; Brennan, Kathleen; Azziz, Ricardo
2011-01-01
Objective To determine whether assessing the extent of terminal hair growth in a subset of the traditional 9 areas included in the modified Ferriman-Gallwey (mFG) score can serve as a simpler predictor of total body hirsutism when compared to the full scoring system, and to determine if this new model can accurately distinguish hirsute from non-hirsute women. Design Cross-sectional analysis Setting Two tertiary care academic referral centers. Patients 1951 patients presenting for symptoms of androgen excess. Interventions History and physical examination, including mFG score. Main Outcome Measures Total body hirsutism. Results A regression model using all nine body areas indicated that the combination of upper abdomen, lower abdomen and chin was the best predictor of the total full mFG score. Using this subset of three body areas is accurate in distinguishing true hirsute from non-hirsute women when defining true hirsutism as mFG>7. Conclusion Scoring terminal hair growth only on the chin and abdomen can serve as a simple, yet reliable predictor of total body hirsutism when compared to full body scoring using the traditional mFG system. PMID:21924716
Impact of multiple sclerosis on quality of life: Comparison with systemic lupus erythematosus.
Carnero Contentti, Edgar; Genco, Néstor David; Hryb, Javier Pablo; Caspi, Mercedes; Chiganer, Edson; Di Pace, José Luis; López, Pablo Adrián; Lessa, Carmen; Caride, Alejandro; Perassolo, Mónica
2017-12-01
To report the impact of multiple sclerosis (MS) on patients' quality of life (QoL) compared to systemic lupus erythematosus (SLE) using the 36-Item Short Form (SF-36) health questionnaire in Argentina. Cross-sectional study. All consecutive MS patients, SLE and healthy controls (HC) were included. Demographics, clinical and radiological aspects, EDSS and SF-36 were assessed. A total of 191 subjects were included (MS=74, SLE=30 and HC=87). When we compared, using 2 standard deviations below the normal mean, the SF-36 subscales scores between MS and SLE, we found that MS patients experienced significant deterioration in general health (p<0.0001), vitality (p=0.009), current health (p<0.0001) and previous year health perception (p=0.003). Additional evaluated areas did not show significant differences. MS patients scored significantly lower in all categories compared to HC, except for bodily pain. An inverse correlation between EDSS and SF-36 total (R 2 =0.59, β -11.08, p<0.0001) and subscale scores was observed after applying regression analysis. MS behaves as a systemic disease from the functional point of view. Patient-reported QoL scales scores provide comprehensive additional prognostic information beyond the EDSS score. Therefore, adding the SF-36 questionnaire in clinical practice might be useful for the assessment and follow-up of MS patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Rasch analysis of the Edmonton Symptom Assessment System and research implications
Cheifetz, O.; Packham, T.L.; MacDermid, J.C.
2014-01-01
Background Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Methods Polytomous Rasch analysis (Andrich’s rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. Results The Rasch reliability index was 0.73, falling short of the desired 0.80–0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0–10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. Conclusions The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions. PMID:24764703
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.
Punjabi, Naresh M; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N
2015-10-01
Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Clinical sleep laboratories. A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90-0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91-0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated scoring platforms provide a viable complement of tools in the diagnostic armamentarium of sleep medicine. © 2015 Associated Professional Sleep Societies, LLC.
Utility of the PASS Theory and Cognitive Assessment System for Dutch Children with and without ADHD
ERIC Educational Resources Information Center
Van Luit, Johannes E. H.; Kroesbergen, Evelyn H.; Naglieri, Jack A.
2005-01-01
This study examined the utility of the Planning, Attention, Simultaneous, Successive (PASS) theory of intelligence as measured by the "Cognitive Assessment System" (CAS) for evaluation of children with attention-deficit/hyperactivity disorder (ADHD). The CAS scores of 51 Dutch children without ADHD were compared to the scores of a group…
Li, J; Guo, X J; Ding, X L; Lyu, B M; Xiao, J; Sun, Q L; Li, D S; Zhang, W F; Zhou, J C; Li, C P; Yang, R C
2018-02-14
Objective: To assess the feasibility of HEAD-US scale in the clinical application of hemophilic arthropathy (HA) and propose an optimized ultrasound scoring system. Methods: From July 2015 to August 2017, 1 035 joints ultrasonographic examinations were performed in 91 patients. Melchiorre, HEAD-US (Hemophilic Early Arthropathy Detection with UltraSound) and HEAD-US-C (HEAD-US in China) scale scores were used respectively to analyze the results. The correlations between three ultrasound scales and Hemophilia Joint Health Scores (HJHS) were evaluated. The sensitivity differences of the above Ultrasonic scoring systems in evaluation of HA were compared. Results: All the 91 patients were male, with median age of 16 (4-55) years old, including 86 cases of hemophilia A and 5 cases hemophilia B. The median ( P 25 , P 75 ) of Melchiorre, HEAD-US and HEAD-US-C scores of 1 035 joints were 2(0,6), 1(0,5) and 2(0,6), respectively, and the correlation coefficients compared with HJHS was 0.747, 0.762 and 0.765 respectively, with statistical significance ( P <0.001). The positive rates of Melchiorre, HEAD-US-C and HEAD-US scale score were 63.0% (95% CI 59.7%-65.9%), 59.5% (95% CI 56.5%-62.4%) and 56.6% (95% CI 53.6%-59.6%) respectively, and the difference was statistically significant ( P <0.001). Even for 336 cases of asymptomatic joints, the positive rates of Melchiorre, HEAD-US-C and HEAD-US scale score were 25.0% (95% CI 20.6%-29.6%), 17.0% (95% CI 12.6%-21.1%) and 11.9% (95% CI 8.4%-15.7%) respectively, and the difference was statistically significant ( P <0.001). There were significant changes ( P <0.05) in the ultrasonographic score of HA before and after onset of hemorrhage in 107 joints of 40 patients. The difference in variation amplitude of HEAD-US-C scores and HEAD-US scores before and after joint bleeding was statistically significant ( P <0.001). Conclusion: Compared with Melchiorre, there were similar good correlations between HEAD-US, HEAD-US-C and HJHS. HEAD-US ultrasound scoring system is quick, convenient and simple to use. The optimized HEAD-US-C scale score is more sensitive than HEAD-US, especially for patients with HA who have subclinical state, which make up for insufficiency of sensitivity in HEAD-US scoring system.
The Effect of Training Data Set Composition on the Performance of a Neural Image Caption Generator
2017-09-01
objects was compared using the Metric for Evaluation of Translation with Explicit Ordering (METEOR) and Consensus-Based Image Description Evaluation...using automated scoring systems. Many such systems exist, including Bilingual Evaluation Understudy (BLEU), Consensus-Based Image Description Evaluation...shown to be essential to automated scoring, which correlates highly with human precision.5 CIDEr uses a system of consensus among the captions and
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System
Punjabi, Naresh M.; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N.
2015-01-01
Study Objectives: Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. Design: The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Setting: Clinical sleep laboratories. Measurements and Results: A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90–0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91–0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Conclusion: Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated scoring platforms provide a viable complement of tools in the diagnostic armamentarium of sleep medicine. Citation: Punjabi NM, Shifa N, Dorffner G, Patil S, Pien G, Aurora RN. Computer-assisted automated scoring of polysomnograms using the Somnolyzer system. SLEEP 2015;38(10):1555–1566. PMID:25902809
Neubrand, Tara L; Roswell, Kelley; Deakyne, Sara; Kocher, Kendra; Wathen, Joseph
2014-07-01
To compare management of acute femur fractures in children who received a fascia iliaca compartment nerve block (FICNB) to those who received systemic intravenously administered analgesics in the pediatric emergency department. The comparison evaluated frequency of use, effectiveness, and associated adverse event profiles. Study population was derived from a retrospective chart review of pediatric patients sustaining acute femur fractures between 2005 and 2009. Cases (received FICNB) were compared with controls (only systemic analgesia) in terms of effectiveness and adverse event. Outcomes included total doses of systemic medications received and comparison of preintervention and postintervention pain scores. Two hundred fifty-nine charts were reviewed: 158 who received FICNB versus 101 who did not. The median dose of systemic medications was 1 dose lower in the FICNB group compared with the systemic medications group. This remained significant after controlling for age and preintervention pain scores (P = 0.02). Median postintervention pain scores in the FICNB group were 1.5 points lower than those in the systemic medications group. This remained significant while controlling for preintervention pain scores and age (P < 0.01). There was no difference in the total adverse events between the FICNB and the control group in either the unadjusted or adjusted analyses (P = 0.08). The FICNB group had 2 seizure episodes, one of which had associated subarachnoid hemorrhage. No patient in either group experienced bradycardia, arrhythmia, visual disturbance, abnormal hearing, mouth numbness, motor tremors, pain or bleeding at injection site, or prolonged nerve block. We report on the largest number of FICNBs administered in a pediatric emergency department for acute femur fractures. Effectiveness, as measured by pain scores and total doses of systemic analgesia, was improved in the FICNB group versus the control. There was no difference in adverse events between the groups.
Tornese, Davide; Mattei, Enrico; Lucchesi, Giampaolo; Bandi, Marco; Ricci, Gabriele; Melegati, Gianluca
2008-09-01
To describe and compare two extracorporeal shock wave therapy techniques for the treatment of painful subcalcaneal spur. Random assignment to two groups of treatment with two and eight months follow-up. The data were collected in outpatients. Forty-five subjects with a history of at least six months of heel pain were studied. Each subject received a three-session ultrasound-guided extracorporeal shock wave therapy (performed weekly). Perpendicular technique was used in group A (n=22, mean age 59.3 +/- 12 years) and tangential technique was used in group B (n= 23, mean age 58.8 +/- 12.3 years). Mayo Clinical Scoring System was used to evaluate each subject before the treatment and at two and eight months follow-up. Mayo Clinical Scoring System pretreatment scores were homogeneous between the groups (group A 55.2 +/-18.7; group B 53.5 +/- 20; P>0.05). In both groups there was a significant (P<0.05) increase in the Mayo Clinical Scoring System score at two months (group A 83.9 +/- 13.7; group B 80 +/- 15,8) and eight months (group A 90 +/- 10.5; group B 90.2 +/-8.7) follow-up. No significant differences were obtained comparing the Mayo Clinical Scoring System scores of the two groups at two and eight months follow-up. There was no difference between the two techniques of using extracorporeal shock wave therapy. The tangential technique was found to be better tolerated as regards treatment-induced pain, allowing higher energy dosages to be used.
O'Driscoll, Keelin Km; Hanlon, Alison; French, Padraig; Boyle, Laura A
2009-02-01
Lameness is one of the most serious health and welfare problems for dairy cows. This study compared hoof health, limb health and locomotion of dairy cows in three over-winter management systems. Treatments were: (1) an indoor free-stall system (FS), (2) outdoors on an uncovered woodchip pad (UP) and (3) outdoors on a covered woodchip pad (CP). Animals were assigned to treatments at drying off, remained on treatment until parturition, then turned out to pasture. Sole lesions were scored on assignment to treatment, at calving, and 6 weeks and 12 weeks post partum. Locomotion and skin lesions were scored on assignment to treatment, and every 2 weeks until parturition. Post-partum locomotion was scored weekly for 13 weeks. More FS cows were affected by limb lesions than CP cows, and these animals had the worst locomotion scores post calving. There was an effect of inspection, and interactive effect of inspection and treatment on sole lesion scores. UP cows had the highest sole lesion scores 12 weeks post partum probably due to softening of the hooves arising from exposure to moisture while on the woodchip pad. However, post partum, UP cows had better locomotion scores, and CP cows tended to have better scores than cows in FS. Both of these treatments were less likely to have a high tracking-up score than cows in FS. It is possible that cows in this treatment were able to exercise more, owing to the secure underfoot surface and lack of barriers, and this promoted limb flexibility. Although woodchip pads provided benefits for limb health and locomotion, the wood chip surface in both outdoor systems did not offer protective benefits to the hooves relative to housing on concrete. However, the provision of shelter on the pad somewhat overcame the problem of high sole lesion scores in the post-partum period.
Jakimov, Tamara; Mrdović, Igor; Filipović, Branka; Zdravković, Marija; Djoković, Aleksandra; Hinić, Saša; Milić, Nataša; Filipović, Branislav
2017-12-31
To compare the prognostic performance of three major risk scoring systems including global registry for acute coronary events (GRACE), thrombolysis in myocardial infarction (TIMI), and prediction of 30-day major adverse cardiovascular events after primary percutaneous coronary intervention (RISK-PCI). This single-center retrospective study involved 200 patients with acute coronary syndrome (ACS) who underwent invasive diagnostic approach, ie, coronary angiography and myocardial revascularization if appropriate, in the period from January 2014 to July 2014. The GRACE, TIMI, and RISK-PCI risk scores were compared for their predictive ability. The primary endpoint was a composite 30-day major adverse cardiovascular event (MACE), which included death, urgent target-vessel revascularization (TVR), stroke, and non-fatal recurrent myocardial infarction (REMI). The c-statistics of the tested scores for 30-day MACE or area under the receiver operating characteristic curve (AUC) with confidence intervals (CI) were as follows: RISK-PCI (AUC=0.94; 95% CI 1.790-4.353), the GRACE score on admission (AUC=0.73; 95% CI 1.013-1.045), the GRACE score on discharge (AUC=0.65; 95% CI 0.999-1.033). The RISK-PCI score was the only score that could predict TVR (AUC=0.91; 95% CI 1.392-2.882). The RISK-PCI scoring system showed an excellent discriminative potential for 30-day death (AUC=0.96; 95% CI 1.339-3.548) in comparison with the GRACE scores on admission (AUC=0.88; 95% CI 1.018-1.072) and on discharge (AUC=0.78; 95% CI 1.000-1.058). In comparison with the GRACE and TIMI scores, RISK-PCI score showed a non-inferior ability to predict 30-day MACE and death in ACS patients. Moreover, RISK-PCI was the only scoring system that could predict recurrent ischemia requiring TVR.
Jakimov, Tamara; Mrdović, Igor; Filipović, Branka; Zdravković, Marija; Djoković, Aleksandra; Hinić, Saša; Milić, Nataša; Filipović, Branislav
2017-01-01
Aim To compare the prognostic performance of three major risk scoring systems including global registry for acute coronary events (GRACE), thrombolysis in myocardial infarction (TIMI), and prediction of 30-day major adverse cardiovascular events after primary percutaneous coronary intervention (RISK-PCI). Methods This single-center retrospective study involved 200 patients with acute coronary syndrome (ACS) who underwent invasive diagnostic approach, ie, coronary angiography and myocardial revascularization if appropriate, in the period from January 2014 to July 2014. The GRACE, TIMI, and RISK-PCI risk scores were compared for their predictive ability. The primary endpoint was a composite 30-day major adverse cardiovascular event (MACE), which included death, urgent target-vessel revascularization (TVR), stroke, and non-fatal recurrent myocardial infarction (REMI). Results The c-statistics of the tested scores for 30-day MACE or area under the receiver operating characteristic curve (AUC) with confidence intervals (CI) were as follows: RISK-PCI (AUC = 0.94; 95% CI 1.790-4.353), the GRACE score on admission (AUC = 0.73; 95% CI 1.013-1.045), the GRACE score on discharge (AUC = 0.65; 95% CI 0.999-1.033). The RISK-PCI score was the only score that could predict TVR (AUC = 0.91; 95% CI 1.392-2.882). The RISK-PCI scoring system showed an excellent discriminative potential for 30-day death (AUC = 0.96; 95% CI 1.339-3.548) in comparison with the GRACE scores on admission (AUC = 0.88; 95% CI 1.018-1.072) and on discharge (AUC = 0.78; 95% CI 1.000-1.058). Conclusions In comparison with the GRACE and TIMI scores, RISK-PCI score showed a non-inferior ability to predict 30-day MACE and death in ACS patients. Moreover, RISK-PCI was the only scoring system that could predict recurrent ischemia requiring TVR. PMID:29308832
Self-Monitoring Assessments for Educational Accountability Systems
ERIC Educational Resources Information Center
Koretz, Daniel; Beguin, Anton
2010-01-01
Test-based accountability is now the cornerstone of U.S. education policy, and it is becoming more important in many other nations as well. Educators sometimes respond to test-based accountability in ways that produce score inflation. In the past, score inflation has usually been evaluated by comparing trends in scores on a high-stakes test to…
Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand
2013-04-01
The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value < 0.001. The scintigraphic scoring system had a sensitivity of 93.9% in assessing treatment response to domperidone, specificity of 83.3% i.e., 83.3% of children with no decline in scintigraphic scores show no clinical response to Domperidone. The scintigraphic scoring system had a positive predictive value of 96.9% and a negative predictive value of 71.4%. GERS with its quantitative parameters is a good investigation for assessing the severity of reflux and also for following children post-treatment.
64 slice MDCT generally underestimates coronary calcium scores as compared to EBT: A phantom study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greuter, M. J. W.; Dijkstra, H.; Groen, J. M.
The objective of our study was the determination of the influence of the sequential and spiral acquisition modes on the concordance and deviation of the calcium score on 64-slice multi-detector computed tomography (MDCT) scanners in comparison to electron beam tomography (EBT) as the gold standard. Our methods and materials were an anthropomorphic cardio CT phantom with different calcium inserts scanned in sequential and spiral acquisition modes on three identical 64-slice MDCT scanners of manufacturer A and on three identical 64-slice MDCT scanners of manufacturer B and on an EBT system. Every scan was repeated 30 times with and 15 timesmore » without a small random variation in the phantom position for both sequential and spiral modes. Significant differences were observed between EBT and 64-slice MDCT data for all inserts, both acquisition modes, and both manufacturers of MDCT systems. High regression coefficients (0.90-0.98) were found between the EBT and 64-slice MDCT data for both scoring methods and both systems with high correlation coefficients (R{sup 2}>0.94). System A showed more significant differences between spiral and sequential mode than system B. Almost no differences were observed in scanners of the same manufacturer for the Agatston score and no differences for the Volume score. The deviations of the Agatston and Volume scores showed regression dependencies approximately equal to the square root of the absolute score. The Agatston and Volume scores obtained with 64-slice MDCT imaging are highly correlated with EBT-obtained scores but are significantly underestimated (-10% to -2%) for both sequential and spiral acquisition modes. System B is more independent of acquisition mode to calcium score than system A. The Volume score shows no intramanufacturer dependency and its use is advocated versus the Agatston score. Using the same cut points for MDCT-based calcium scores as for EBT-based calcium scores can result in classifying individuals into a too low risk category. System information and scanprotocol is therefore needed for every calcium score procedure to ensure a correct clinical interpretation of the obtained calcium score results.« less
Marmé, Frederik; Lederer, Bianca; Blohmer, Jens-Uwe; Costa, Serban Dan; Denkert, Carsten; Eidtmann, Holger; Gerber, Bernd; Hanusch, Claus; Hilfrich, Jörn; Huober, Jens; Jackisch, Christian; Kümmel, Sherko; Loibl, Sibylle; Paepke, Stefan; Untch, Michael; von Minckwitz, Gunter; Schneeweiss, Andreas
2016-01-01
Pathologic complete response after neoadjuvant chemotherapy (NACT) correlates with overall survival (OS) in primary breast cancer. A recently described staging system based on pre-treatment clinical stage (CS), final pathological stage (PS), estrogen receptor (ER) status and nuclear grade (NG) leads to a refined estimation of prognosis in unselected patients. Its performance in luminal type breast cancers has not been determined. This study investigates the clinical utility of this CPS+EG score when restricted to hormone receptor-positive (HR+)/human epidermal growth factor receptor 2-negative (HER2-) patients and compares the results to a cohort of unselected patients. The CPS+EG score was calculated for 6637 unselected patients and 2454 patients with HR+/HER2- tumours who received anthracycline/taxane-based NACT within 8 prospective German trials. Five-year disease-free survival (DFS) and OS were 75.6% and 84.1% for the unselected cohort and 80.6% and 87.8% for the HR+/HER2- subgroup, respectively. The CPS+EG system distinguished different prognostic groups with 5-year DFS ranging from 0% to 91%. The CPS+EG system leads to an improved categorisation of patients by outcome compared to CS, PS, ER or NG alone. When applying the CPS+EG score to the HR+/HER2- subgroup, a shift to lower scores was observed compared to the overall population, but 5-year DFS and OS for the individual scores were identical to that observed in the overall population. In HR+/HER2- patients, the CPS+EG staging system retains its ability to facilitate a refined stratification of patients according to outcome. It can help to select candidates for post-neoadjuvant clinical trials in luminal breast cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shore, Neal D; Sethi, Parminder S
2010-09-01
Compare safety and tolerability of the Prolieve(®) System with the Targis(®) System using objective and subjective measures. Thirty-four men with symptomatic benign prostatic hyperplasia (BPH) were randomized to a single treatment with either the Prolieve or Targis system; 30 were treated and then followed for 6 months. After post-treatment bladder fill with ≥200 mL saline, patients were catheterized if they could not void after 2 hours or had a postvoid residual >150 mL. Catheter use, visual analog scale (VAS) tolerability scores, American Urological Association scores, and safety were assessed. After treatment, 15/16 (94%) Prolieve patients remained catheter-free compared with 3/14 (21%) Targis patients (P = 0.0001). Foley catheter indwelling time was 58.8 hours for the one Prolieve patient compared with 103.9 hrs (range 54-270 h) for the Targis patients (n = 9). Targis patients' catheterization requirements were: Seven Foley only, two intermittent self-catheters only, and two needing both. Intermittent self-catheterization continued for 1 month in two Targis patients. VAS tolerability scores were 24% to 50% lower during Prolieve treatment vs Targis (P < 0.05). Mean AUA scores for Prolieve improved from 21.2 at baseline to 12.3 and 7.9 at week 2 and month 6, respectively; for Targis, AUA scores improved from 22.9 at baseline to 17.9 and 10.9, respectively (P > 0.05). Overall, the incidence of device-related adverse events was 31% (Prolieve) compared with 64% (Targis) (P > 0.05)-most prevalently, urinary retention, dysuria, and hematuria. No device-related serious adverse events occurred. Prolieve provided enhanced near-term therapeutic benefit over Targis as assessed by catheterization, tolerability, and symptom relief, which may assist physician and patient decision-making when selecting an office-based transurethral microwave therapy option for patients.
Zhou, Lin; Guo, Jianming; Wang, Hang; Wang, Guomin
2015-02-01
In the zero ischemia era of nephron-sparing surgery (NSS), a new anatomic classification system (ACS) is needed to adjust to these new surgical techniques. We devised a novel and simple ACS, and compared it with the RENAL and PADUA scores to predict the risk of NSS outcomes. We retrospectively evaluated 789 patients who underwent NSS with available imaging between January 2007 and July 2014. Demographic and clinical data were assessed. The Zhongshan (ZS) score consisted of three parameters. RENAL, PADUA, and ZS scores are divided into three groups, that is, high, moderate, and low scores. For operative time (OT), significant differences were seen between any two groups of ZS score and PADUA score (all P < 0.05). For ZS score, patients with moderate and high scores had longer warm ischemia time (WIT) and greater increase in SCr compared with low score (all P < 0.05). What is more, the differences between moderate and high scores classified by ZS score were borderline but trending toward significance in WIT (P = 0.064) and increase in SCr (P = 0.052). Interestingly, RENAL showed no significant difference between moderate and high complexity in OT, WIT, estimated blood loss, and increase in SCr. Compared with patients with a low score of ZS, those with a high or moderate score had 8.1-fold or 3.3-fold higher risk of surgical complications, respectively (all P < 0.05). As for RENAL score, patients with a high or moderate score had 5.7-fold or 1.9-fold higher risk of surgical complications, respectively (all P < 0.05). Patients with a high or moderate score of PADUA had 2.3-fold or 2.8-fold higher risk of surgical complications, respectively (all P < 0.05). In the ROC curve analysis, ZS score had the greatest AUC for surgical complications (AUC = 0.632) and the conversion to radical nephrectomy (AUC = 0.845) (all P < 0.05). In conclusion, the ability of ZS score to predict the surgical complexity and surgical complications of NSS is better than RENAL and PADUA scores. ZS score could be used to reflect the surgical complexity and predict the risk of surgical complications in patients undergoing NSS.
Modified scoring criteria for the RBANS figures.
Duff, Kevin; Leber, W R; Patton, Doyle E; Schoenberg, Mike R; Mold, James W; Scott, James G; Adams, Russell L
2007-01-01
Visual construction and memory tasks are routinely used in neuropsychological assessment, but their subjective scoring criteria can negatively affect the reliability of these instruments. The current study examined the standard scoring criteria for the Figure Copy and Recall subtests of the RBANS and compared them to a modified set of scoring criteria in two samples. In both a large community dwelling sample of older adults and in a mixed clinical sample, the original scoring criteria consistently led to lower scores than the modified criteria. Inter-rater reliability was high for the modified scoring criteria, and no age effects were found with the modified scoring criteria. In both samples, the modified scoring criteria led to Figure Copy scores that more closely approximated other performances on the RBANS compared to the standard criteria, whereas both scoring systems led to plausible Figure Recall scores. Despite these results, the present study cannot identify one scoring criterion as the "better," but only points out the significant differences between them. Such differences can have important clinical implications, and practitioners and researchers who utilize the RBANS with patient samples should be cautious when interpreting low scores on Figure Copy and Recall if the standard criteria are used.
Scope Complexity Options Risks Excursions (SCORE) Factor Mathematical Description.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gearhart, Jared Lee; Samberson, Jonell Nicole; Shettigar, Subhasini
The purpose of the Scope, Complexity, Options, Risks, Excursions (SCORE) model is to estimate the relative complexity of design variants of future warhead options, resulting in scores. SCORE factors extend this capability by providing estimates of complexity relative to a base system (i.e., all design options are normalized to one weapon system). First, a clearly defined set of scope elements for a warhead option is established. The complexity of each scope element is estimated by Subject Matter Experts (SMEs), including a level of uncertainty, relative to a specific reference system. When determining factors, complexity estimates for a scope element canmore » be directly tied to the base system or chained together via comparable scope elements in a string of reference systems that ends with the base system. The SCORE analysis process is a growing multi-organizational Nuclear Security Enterprise (NSE) effort, under the management of the NA-12 led Enterprise Modeling and Analysis Consortium (EMAC). Historically, it has provided the data elicitation, integration, and computation needed to support the out-year Life Extension Program (LEP) cost estimates included in the Stockpile Stewardship Management Plan (SSMP).« less
Lameness scoring system for dairy cows using force plates and artificial intelligence.
Ghotoorlar, S Mokaram; Ghamsari, S Mehdi; Nowrouzian, I; Ghotoorlar, S Mokaram; Ghidary, S Shiry
2012-02-04
Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5.
Datta, Rakesh; Datta, Karuna; Venkatesh, M D
2015-07-01
The classical didactic lecture has been the cornerstone of the theoretical undergraduate medical education. Their efficacy however reduces due to reduced interaction and short attention span of the students. It is hypothesized that the interactive response pad obviates some of these drawbacks. The aim of this study was to evaluate the effectiveness of an interactive response system by comparing it with conventional classroom teaching. A prospective comparative longitudinal study was conducted on 192 students who were exposed to either conventional or interactive teaching over 20 classes. Pre-test, Post-test and retentions test (post 8-12 weeks) scores were collated and statistically analysed. An independent observer measured number of student interactions in each class. Pre-test scores from both groups were similar (p = 0.71). There was significant improvement in both post test scores when compared to pre-test scores in either method (p < 0.001). The interactive post-test score was better than conventional post test score (p < 0.001) by 8-10% (95% CI-difference of means - 8.2%-9.24%-10.3%). The interactive retention test score was better than conventional retention test score (p < 0.001) by 15-18% (95% CI-difference of means - 15.0%-16.64%-18.2%). There were 51 participative events in the interactive group vs 25 in the conventional group. The Interactive Response Pad method was efficacious in teaching. Students taught with the interactive method were likely to score 8-10% higher (statistically significant) in the immediate post class time and 15-18% higher (statistically significant) after 8-12 weeks. The number of student-teacher interactions increases when using the interactive response pads.
Sattin, Davide; Lovaglio, Piergiorgio; Brenna, Greta; Covelli, Venusia; Rossi Sebastiano, Davide; Duran, Dunja; Minati, Ludovico; Giovannetti, Ambra Mara; Rosazza, Cristina; Bersano, Anna; Nigri, Anna; Ferraro, Stefania; Leonardi, Matilde
2017-09-01
The study compared the metric characteristics (discriminant capacity and factorial structure) of two different methods for scoring the items of the Coma Recovery Scale-Revised and it analysed scale scores collected using the standard assessment procedure and a new proposed method. Cross sectional design/methodological study. Inpatient, neurological unit. A total of 153 patients with disorders of consciousness were consecutively enrolled between 2011 and 2013. All patients were assessed with the Coma Recovery Scale-Revised using standard (rater 1) and inverted (rater 2) procedures. Coma Recovery Scale-Revised score, number of cognitive and reflex behaviours and diagnosis. Regarding patient assessment, rater 1 using standard and rater 2 using inverted procedures obtained the same best scores for each subscale of the Coma Recovery Scale-Revised for all patients, so no clinical (and statistical) difference was found between the two procedures. In 11 patients (7.7%), rater 2 noted that some Coma Recovery Scale-Revised codified behavioural responses were not found during assessment, although higher response categories were present. A total of 51 (36%) patients presented the same Coma Recovery Scale-Revised scores of 7 or 8 using a standard score, whereas no overlap was found using the modified score. Unidimensionality was confirmed for both score systems. The Coma Recovery Scale Modified Score showed a higher discriminant capacity than the standard score and a monofactorial structure was also supported. The inverted assessment procedure could be a useful evaluation method for the assessment of patients with disorder of consciousness diagnosis.
Establishment and Validation of GV-SAPS II Scoring System for Non-Diabetic Critically Ill Patients.
Liu, Wen-Yue; Lin, Shi-Gang; Zhu, Gui-Qi; Poucke, Sven Van; Braddock, Martin; Zhang, Zhongheng; Mao, Zhi; Shen, Fei-Xia; Zheng, Ming-Hua
2016-01-01
Recently, glucose variability (GV) has been reported as an independent risk factor for mortality in non-diabetic critically ill patients. However, GV is not incorporated in any severity scoring system for critically ill patients currently. The aim of this study was to establish and validate a modified Simplified Acute Physiology Score II scoring system (SAPS II), integrated with GV parameters and named GV-SAPS II, specifically for non-diabetic critically ill patients to predict short-term and long-term mortality. Training and validation cohorts were exacted from the Multiparameter Intelligent Monitoring in Intensive Care database III version 1.3 (MIMIC-III v1.3). The GV-SAPS II score was constructed by Cox proportional hazard regression analysis and compared with the original SAPS II, Sepsis-related Organ Failure Assessment Score (SOFA) and Elixhauser scoring systems using area under the curve of the receiver operator characteristic (auROC) curve. 4,895 and 5,048 eligible individuals were included in the training and validation cohorts, respectively. The GV-SAPS II score was established with four independent risk factors, including hyperglycemia, hypoglycemia, standard deviation of blood glucose levels (GluSD), and SAPS II score. In the validation cohort, the auROC values of the new scoring system were 0.824 (95% CI: 0.813-0.834, P< 0.001) and 0.738 (95% CI: 0.725-0.750, P< 0.001), respectively for 30 days and 9 months, which were significantly higher than other models used in our study (all P < 0.001). Moreover, Kaplan-Meier plots demonstrated significantly worse outcomes in higher GV-SAPS II score groups both for 30-day and 9-month mortality endpoints (all P< 0.001). We established and validated a modified prognostic scoring system that integrated glucose variability for non-diabetic critically ill patients, named GV-SAPS II. It demonstrated a superior prognostic capability and may be an optimal scoring system for prognostic evaluation in this patient group.
Patterson, Brendan M; Orvets, Nathan D; Aleem, Alexander W; Keener, Jay D; Calfee, Ryan P; Nixon, Devon C; Chamberlain, Aaron M
2018-06-01
The Patient-Reported Outcomes Measurement Information System (PROMIS) is being used to assess outcomes in many patient populations despite limited validation. The purpose of this study was to investigate the relationship between American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores and PROMIS Physical Function (PF) and Upper Extremity (UE) function scores collected preoperatively in patients undergoing rotator cuff repair. This cross-sectional study analyzed 164 consecutive patients undergoing arthroscopic rotator cuff repair. Study inclusion required preoperative completion of the ASES and SST evaluations, as well as the PROMIS PF, UE, and Pain Interference computerized adaptive tests. Descriptive statistics were produced, and Pearson correlation coefficients were calculated between each of the outcome measures. Average PROMIS UE scores indicated greater impairment than PROMIS PF scores (34 vs 44). Three percent of patients reached the PROMIS UE ceiling score of 56. PROMIS PF scores demonstrated a weak correlation with ASES scores (r = 0.43, P < .001) and a moderate correlation with SST scores (r = 0.51, P < .001). PROMIS UE scores demonstrated a moderate correlation with both ASES scores (r = 0.59, P < .001) and SST scores (r = 0.62, P < .001). PROMIS Pain Interference scores demonstrated weak negative correlations with both ASES scores (r = -0.43, P < .001) and SST scores (r = -0.41, P < .001). Patients answered fewer questions on average using the PROMIS PF and UE instruments as compared with the ASES and SST instruments. PROMIS UE scores indicate greater impairment and demonstrate a stronger correlation with the legacy shoulder scores than PROMIS PF scores in patients with symptomatic rotator cuff tears. PROMIS computerized adaptive tests allow for more efficient patient-reported outcome data collection compared with traditional outcome scores. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Ogunyemi, Dotun; Eno, Michelle; Rad, Steve; Fong, Alex; Alexander, Carolyn; Azziz, Ricardo
2010-01-01
Objective The purpose of this article was to develop and determine the utility of a compliance form in evaluating and teaching the Accreditation Council for Graduate Medical Education competencies of professionalism, practice-based learning and improvement, and systems-based practice. Methods In 2006, we introduced a 17-item compliance form in an obstetrics and gynecology residency program. The form prospectively monitored residents on attendance at required activities (5 items), accountability of required obligations (9 items), and completion of assigned projects (3 items). Scores were compared to faculty evaluations of residents, resident status as a contributor or a concerning resident, and to the residents' conflict styles, using the Thomas-Kilmann Conflict MODE Instrument. Results Our analysis of 18 residents for academic year 2007–2008 showed a mean (standard error of mean) of 577 (65.3) for postgraduate year (PGY)-1, 692 (42.4) for PGY-2, 535 (23.3) for PGY-3, and 651.6 (37.4) for PGY-4. Non-Hispanic white residents had significantly higher scores on compliance, faculty evaluations on interpersonal and communication skills, and competence in systems-based practice. Contributing residents had significantly higher scores on compliance compared with concerning residents. Senior residents had significantly higher accountability scores compared with junior residents, and junior residents had increased project completion scores. Attendance scores increased and accountability scores decreased significantly between the first and second 6 months of the academic year. There were positive correlations between compliance scores with competing and collaborating conflict styles, and significant negative correlations between compliance with avoiding and accommodating conflict styles. Conclusions Maintaining a compliance form allows residents and residency programs to focus on issues that affect performance and facilitate assessment of the ACGME competencies. Postgraduate year, behavior, and conflict styles appear to be associated with compliance. A lack of association with faculty evaluations suggests measurement of different perceptions of residents' behavior. PMID:21976093
Ogunyemi, Dotun; Eno, Michelle; Rad, Steve; Fong, Alex; Alexander, Carolyn; Azziz, Ricardo
2010-09-01
The purpose of this article was to develop and determine the utility of a compliance form in evaluating and teaching the Accreditation Council for Graduate Medical Education competencies of professionalism, practice-based learning and improvement, and systems-based practice. In 2006, we introduced a 17-item compliance form in an obstetrics and gynecology residency program. The form prospectively monitored residents on attendance at required activities (5 items), accountability of required obligations (9 items), and completion of assigned projects (3 items). Scores were compared to faculty evaluations of residents, resident status as a contributor or a concerning resident, and to the residents' conflict styles, using the Thomas-Kilmann Conflict MODE Instrument. Our analysis of 18 residents for academic year 2007-2008 showed a mean (standard error of mean) of 577 (65.3) for postgraduate year (PGY)-1, 692 (42.4) for PGY-2, 535 (23.3) for PGY-3, and 651.6 (37.4) for PGY-4. Non-Hispanic white residents had significantly higher scores on compliance, faculty evaluations on interpersonal and communication skills, and competence in systems-based practice. Contributing residents had significantly higher scores on compliance compared with concerning residents. Senior residents had significantly higher accountability scores compared with junior residents, and junior residents had increased project completion scores. Attendance scores increased and accountability scores decreased significantly between the first and second 6 months of the academic year. There were positive correlations between compliance scores with competing and collaborating conflict styles, and significant negative correlations between compliance with avoiding and accommodating conflict styles. Maintaining a compliance form allows residents and residency programs to focus on issues that affect performance and facilitate assessment of the ACGME competencies. Postgraduate year, behavior, and conflict styles appear to be associated with compliance. A lack of association with faculty evaluations suggests measurement of different perceptions of residents' behavior.
Maharjan, Namita; Nomoto, Naoki; Tagawa, Tadashi; Okubo, Tsutomu; Uemura, Shigeki; Khalil, Nadeem; Hatamoto, Masashi; Yamaguchi, Takashi; Harada, Hideki
2018-04-06
This paper assesses the technical and economic sustainability of a combined system of an up-flow anaerobic sludge blanket (UASB)-down-flow hanging sponge (DHS) for sewage treatment. Additionally, this study compares UASB-DHS with current technologies in India like trickling filters (TF), sequencing batch reactor (SBR), moving bed biofilm reactor (MBBR), and other combinations of UASB with post-treatment systems such as final polishing ponds (FPU) and extended aeration sludge process (EASP). The sustainability of the sewage treatment plants (STPs) was evaluated using a composite indicator, which incorporated environmental, societal, and economic dimensions. In case of the individual sustainability indicator study, the results showed that UASB-FPU was the most economically sustainable system with a score of 0.512 and aeration systems such as MBBR, EASP, and SBR were environmentally sustainable, whereas UASB-DHS system was socially sustainable. However, the overall comparative analysis indicated that the UASB-DHS system scored the highest value of 2.619 on the global sustainability indicator followed by EASP and MBBR with scores of 2.322 and 2.279, respectively. The highlight of this study was that the most environmentally sustainable treatment plants were not economically and socially sustainable. Moreover, sensitivity analysis showed that five out of the seven scenarios tested, the UASB-DHS system showed good results amongst the treatment system.
Kim, Yun Hak; Jeong, Dae Cheon; Pak, Kyoungjune; Goh, Tae Sik; Lee, Chi-Seung; Han, Myoung-Eun; Kim, Ji-Young; Liangwen, Liu; Kim, Chi Dae; Jang, Jeon Yeob; Cha, Wonjae; Oh, Sae-Ock
2017-09-29
Accurate prediction of prognosis is critical for therapeutic decisions regarding cancer patients. Many previously developed prognostic scoring systems have limitations in reflecting recent progress in the field of cancer biology such as microarray, next-generation sequencing, and signaling pathways. To develop a new prognostic scoring system for cancer patients, we used mRNA expression and clinical data in various independent breast cancer cohorts (n=1214) from the Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and Gene Expression Omnibus (GEO). A new prognostic score that reflects gene network inherent in genomic big data was calculated using Network-Regularized high-dimensional Cox-regression (Net-score). We compared its discriminatory power with those of two previously used statistical methods: stepwise variable selection via univariate Cox regression (Uni-score) and Cox regression via Elastic net (Enet-score). The Net scoring system showed better discriminatory power in prediction of disease-specific survival (DSS) than other statistical methods (p=0 in METABRIC training cohort, p=0.000331, 4.58e-06 in two METABRIC validation cohorts) when accuracy was examined by log-rank test. Notably, comparison of C-index and AUC values in receiver operating characteristic analysis at 5 years showed fewer differences between training and validation cohorts with the Net scoring system than other statistical methods, suggesting minimal overfitting. The Net-based scoring system also successfully predicted prognosis in various independent GEO cohorts with high discriminatory power. In conclusion, the Net-based scoring system showed better discriminative power than previous statistical methods in prognostic prediction for breast cancer patients. This new system will mark a new era in prognosis prediction for cancer patients.
Kim, Yun Hak; Jeong, Dae Cheon; Pak, Kyoungjune; Goh, Tae Sik; Lee, Chi-Seung; Han, Myoung-Eun; Kim, Ji-Young; Liangwen, Liu; Kim, Chi Dae; Jang, Jeon Yeob; Cha, Wonjae; Oh, Sae-Ock
2017-01-01
Accurate prediction of prognosis is critical for therapeutic decisions regarding cancer patients. Many previously developed prognostic scoring systems have limitations in reflecting recent progress in the field of cancer biology such as microarray, next-generation sequencing, and signaling pathways. To develop a new prognostic scoring system for cancer patients, we used mRNA expression and clinical data in various independent breast cancer cohorts (n=1214) from the Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and Gene Expression Omnibus (GEO). A new prognostic score that reflects gene network inherent in genomic big data was calculated using Network-Regularized high-dimensional Cox-regression (Net-score). We compared its discriminatory power with those of two previously used statistical methods: stepwise variable selection via univariate Cox regression (Uni-score) and Cox regression via Elastic net (Enet-score). The Net scoring system showed better discriminatory power in prediction of disease-specific survival (DSS) than other statistical methods (p=0 in METABRIC training cohort, p=0.000331, 4.58e-06 in two METABRIC validation cohorts) when accuracy was examined by log-rank test. Notably, comparison of C-index and AUC values in receiver operating characteristic analysis at 5 years showed fewer differences between training and validation cohorts with the Net scoring system than other statistical methods, suggesting minimal overfitting. The Net-based scoring system also successfully predicted prognosis in various independent GEO cohorts with high discriminatory power. In conclusion, the Net-based scoring system showed better discriminative power than previous statistical methods in prognostic prediction for breast cancer patients. This new system will mark a new era in prognosis prediction for cancer patients. PMID:29100405
Willaert, Willem I M; Cheshire, Nicholas J; Aggarwal, Rajesh; Van Herzeele, Isabelle; Stansby, Gerard; Macdonald, Sumaira; Vermassen, Frank E
2012-12-01
Carotid artery stenting (CAS) is a technically demanding procedure with a risk of periprocedural stroke. A scoring system based on anatomic criteria has been developed to facilitate patient selection for CAS. Advancements in simulation science also enable case evaluation through patient-specific virtual reality (VR) rehearsal on an endovascular simulator. This study aimed to validate the anatomic scoring system for CAS using the patient-specific VR technology. Three patients were selected and graded according to the CAS scoring system (maximum score, 9): one easy (score, <4.9), one intermediate (score, 5.0-5.9), and one difficult (score, >7.0). The three cases were performed on the simulator in random order by 20 novice interventionalists pretrained in CAS. Technical performances were assessed using simulator-based metrics and expert-based ratings. The interventionalists took significantly longer to perform the difficult CAS case (median, 31.6 vs 19.7 vs 14.6 minutes; P<.0001) compared with the intermediate and easy cases; similarly, more fluoroscopy time (20.7 vs 12.1 vs 8.2 minutes; P<.0001), contrast volume (56.5 vs 51.5 vs 50.0 mL; P=.0060), and roadmaps (10 vs 9 vs 9; P=.0040) were used. The quality of performance declined significantly as the cases became more challenging (score, 24 vs 22 vs 19; P<.0001). The anatomic scoring system for CAS can predict the difficulty of a CAS procedure as measured by patient-specific VR. This scoring system, with or without the additional use of patient-specific VR, can guide novice interventionalists in selecting appropriate patients for CAS. This may reduce the perioperative stroke risk and enhance patient safety. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Burnout among workers in a pediatric health care system.
Jacobs, Linda M; Nawaz, Muhammad K; Hood, Joyce L; Bae, Sejong
2012-08-01
Burnout among health care workers is recognized as an organizational risk contributing to absenteeism, presenteeism, excessive turnover, or illness, and may also manifest as decreased patient satisfaction. Pediatric health care may add stressors including worried parents of ill or dying children, child custody issues, child abuse, and workplace violence. The purpose of this study was to measure burnout among workers in a regional pediatric health care system and report whether burnout in a pediatric health care system is different from previously published data on human service workers. The Maslach Burnout Inventory-Human Services Survey (MBI-HSS) and the Copenhagen Burnout Inventory (CBI) were used to measure burnout. Pediatric health care workers expressed significantly less burnout as compared to published MBI-HSS scores and client-related CBI scores. Personal burnout CBI scores were not different, but work-related CBI scores were significantly higher than normative scores. Copyright 2012, SLACK Incorporated.
Vicentini, Fabio C; Serzedello, Felipe R; Thomas, Kay; Marchini, Giovanni S; Torricelli, Fabio C M; Srougi, Miguel; Mazzucchi, Eduardo
2017-01-01
To compare the application time and the capacity of the nomograms to predict the success of Guy's Stone Score (GSS), S.T.O.N.E. Nephrolithometry (STONE) and Clinical Research Office of the Endourological Society nephrolithometric nomogram (CROES) of percutaneous nephrolithotomy (PCNL), evaluating the most efficient one for clinical use. We studied 48 patients who underwent PCNL by the same surgeon between 2010 and 2011. We calculated GSS, STONE and CROES based on preoperative non-contrast computed tomography (CT) images and clinical data. A single observer, blinded to the outcomes, reviewed all images and assigned scores. We compared the application time of each nomogram. We used an analysis of variance for repeated measures and multiple comparisons by the Tukey test. We compared the area under the ROC curve (AUC) of the three nomograms two by two to determine the most predictive scoring system. The immediate success rate was 66.7% and complications occurred in 16.7% of cases. The average operative time was 122 minutes. Mean application time was significantly lower for the GSS (27.5 seconds) when compared to 300.6 seconds for STONE and 213.4 seconds for CROES (p<0.001). There was no significant difference among the GSS (AUC=0.653), STONE (AUC=0.563) and CROES (AUC=0.641) in the ability to predict immediate success of PCNL. All three nomograms showed similar ability to predict success of PCNL, however the GSS was the quickest to be applied, what is an important issue for routine clinical use when counseling patients who are candidates to PCNL. Copyright® by the International Brazilian Journal of Urology.
Ma, Yucheng; Wang, Qing; Yang, Jiayin; Yan, Lunan
2015-01-01
In order to provide a good match between donor and recipient in liver transplantation, four scoring systems [the product of donor age and Model for End-stage Liver Disease score (D-MELD), the score to predict survival outcomes following liver transplantation (SOFT), the balance of risk score (BAR), and the transplant risk index (TRI)] based on both donor and recipient parameters were designed. This study was conducted to evaluate the performance of the four scores in living donor liver transplantation (LDLT) and compare them with the MELD score. The clinical data of 249 adult patients undergoing LDLT in our center were retrospectively evaluated. The area under the receiver operating characteristic curves (AUCs) of each score were calculated and compared at 1-, 3-, 6-month and 1-year after LDLT. The BAR at 1-, 3-, 6-month and 1-year after LDLT and the D-MELD and TRI at 1-, 3- and 6-month after LDLT showed acceptable performances in the prediction of survival (AUC>0.6), while the SOFT showed poor discrimination at 6-month after LDLT (AUC = 0.569). In addition, the D-MELD and BAR displayed positive correlations with the length of ICU stay (D-MELD, p = 0.025; BAR, p = 0.022). The SOFT was correlated with the time of mechanical ventilation (p = 0.022). The D-MELD, BAR and TRI provided acceptable performance in predicting survival after LDLT. However, even though these scoring systems were based on both donor and recipient parameters, only the BAR provided better performance than the MELD in predicting 1-year survival after LDLT.
2015-01-01
Background and Objectives In order to provide a good match between donor and recipient in liver transplantation, four scoring systems [the product of donor age and Model for End-stage Liver Disease score (D-MELD), the score to predict survival outcomes following liver transplantation (SOFT), the balance of risk score (BAR), and the transplant risk index (TRI)] based on both donor and recipient parameters were designed. This study was conducted to evaluate the performance of the four scores in living donor liver transplantation (LDLT) and compare them with the MELD score. Patients and Methods The clinical data of 249 adult patients undergoing LDLT in our center were retrospectively evaluated. The area under the receiver operating characteristic curves (AUCs) of each score were calculated and compared at 1-, 3-, 6-month and 1-year after LDLT. Results The BAR at 1-, 3-, 6-month and 1-year after LDLT and the D-MELD and TRI at 1-, 3- and 6-month after LDLT showed acceptable performances in the prediction of survival (AUC>0.6), while the SOFT showed poor discrimination at 6-month after LDLT (AUC = 0.569). In addition, the D-MELD and BAR displayed positive correlations with the length of ICU stay (D-MELD, p = 0.025; BAR, p = 0.022). The SOFT was correlated with the time of mechanical ventilation (p = 0.022). Conclusion The D-MELD, BAR and TRI provided acceptable performance in predicting survival after LDLT. However, even though these scoring systems were based on both donor and recipient parameters, only the BAR provided better performance than the MELD in predicting 1-year survival after LDLT. PMID:26378786
Feng, Zhihong; Wang, Tao; Liu, Ping; Chen, Sipeng; Xiao, Han; Xia, Ning; Luo, Zhiming; Wei, Bing; Nie, Xiuhong
2017-01-01
We aimed to investigate the efficacy of four severity-of-disease scoring systems in predicting the 28-day survival rate among patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) requiring emergency care. Clinical data of patients with AECOPD who required emergency care were recorded over 2 years. APACHE II, SAPS II, SOFA, and MEDS scores were calculated from severity-of-disease indicators recorded at admission and compared between patients who died within 28 days of admission (death group; 46 patients) and those who did not (survival group; 336 patients). Compared to the survival group, the death group had a significantly higher GCS score, frequency of comorbidities including hypertension and heart failure, and age ( P < 0.05 for all). With all four systems, scores of age, gender, renal inadequacy, hypertension, coronary heart disease, heart failure, arrhythmia, anemia, fracture leading to bedridden status, tumor, and the GCS were significantly higher in the death group than the survival group. The prediction efficacy of the APACHE II and SAPS II scores was 88.4%. The survival rates did not differ significantly between APACHE II and SAPS II ( P = 1.519). Our results may guide triage for early identification of critically ill patients with AECOPD in the emergency department.
ERIC Educational Resources Information Center
Kelly, Sean; Monczunski, Laura
2007-01-01
Traditionally, state accountability systems have measured school-level achievement gains using cross-sectional data, for example, by comparing scores of one year's eighth graders to scores of the next year's eighth graders. This approach produces extremely volatile estimates of value added from year to year. This volatility suggests that the…
Yoo, Tae Keun; Kim, Deok Won; Choi, Soo Beom; Oh, Ein; Park, Jee Soo
2016-01-01
Background Knee osteoarthritis (OA) is the most common joint disease of adults worldwide. Since the treatments for advanced radiographic knee OA are limited, clinicians face a significant challenge of identifying patients who are at high risk of OA in a timely and appropriate way. Therefore, we developed a simple self-assessment scoring system and an improved artificial neural network (ANN) model for knee OA. Methods The Fifth Korea National Health and Nutrition Examination Surveys (KNHANES V-1) data were used to develop a scoring system and ANN for radiographic knee OA. A logistic regression analysis was used to determine the predictors of the scoring system. The ANN was constructed using 1777 participants and validated internally on 888 participants in the KNHANES V-1. The predictors of the scoring system were selected as the inputs of the ANN. External validation was performed using 4731 participants in the Osteoarthritis Initiative (OAI). Area under the curve (AUC) of the receiver operating characteristic was calculated to compare the prediction models. Results The scoring system and ANN were built using the independent predictors including sex, age, body mass index, educational status, hypertension, moderate physical activity, and knee pain. In the internal validation, both scoring system and ANN predicted radiographic knee OA (AUC 0.73 versus 0.81, p<0.001) and symptomatic knee OA (AUC 0.88 versus 0.94, p<0.001) with good discriminative ability. In the external validation, both scoring system and ANN showed lower discriminative ability in predicting radiographic knee OA (AUC 0.62 versus 0.67, p<0.001) and symptomatic knee OA (AUC 0.70 versus 0.76, p<0.001). Conclusions The self-assessment scoring system may be useful for identifying the adults at high risk for knee OA. The performance of the scoring system is improved significantly by the ANN. We provided an ANN calculator to simply predict the knee OA risk. PMID:26859664
Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran
2017-06-06
The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p < 0.001). In receiver operating characteristic analysis, our category system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p < 0.001) and total GFR decline (area-under-the-curve = 0.796, p < 0.001), and split GFR decline (area-under-the-curve = 0.841, p < 0.001). Peritumoral artery characteristics were independent predictors of renal function outcome after laparoscopic partial nephrectomy.
Pollner, Péter; Horváth, Anna; Mezei, Tamás; Banczerowski, Péter; Czigléczki, Gábor
2018-04-01
Metastatic spinal diseases are common health problems and there is no consensus on the appropriate treatment of metastases in several conditions. Using clinical measures (e.g., survival time and functional status), prognosis prediction systems advise on the appropriate interventions. The aim of this article is to assess and compare 4 widely used scoring systems (revised Tokuhashi, Tomita, van der Linden, and modified Bauer scores) on a single-center cohort. A retrospective study was designed of 329 patients who were subjected to surgery because of metastatic spinal diseases. Subpopulations according to the classifications of the 4 scoring systems were identified. The overall survival was calculated with the Kaplan-Meier formula. The difference between the survival curves of subpopulations was analyzed with log-rank tests. The consistency rates for the 4 scoring systems are calculated as well. The follow-up period was 8 years. The median survival time was 222 days. The overall survival of prognostic categories in 3 scoring systems was significantly different from each other, but we found no differences between the categories of the van der Linden system. In this cohort, the revised Tokuhashi system gave the best approximation for survival, with a mean predictive capability 60.5%. The evaluation of 4 standard scoring systems showed that 3 were self-consistent, although none of systems was able to predict the survival in our cohort. Based on the predictive capability, the revised Tokuhashi system may provide the best predictions with careful examination of individual cases. Copyright © 2018 Elsevier Inc. All rights reserved.
Kim, Bong Hyun; Kim, Kyuseok; Nam, Hae Jeong
2017-01-31
Many previous studies of electroacupuncture used combined therapy of electroacupuncture and systemic manual acupuncture, so it was uncertain which treatment was effective. This study evaluated and compared the effects of systemic manual acupuncture, periauricular electroacupuncture and distal electroacupuncture for treating patients with tinnitus. A randomized, parallel, open-labeled exploratory trial was conducted. Subjects aged 20-75 years who had suffered from idiopathic tinnitus for > 2 weeks were recruited from May 2013 to April 2014. The subjects were divided into three groups by systemic manual acupuncture group (MA), periauricular electroacupuncture group (PE), and distal electroacupuncture group (DE). The groups were selected by random drawing. Nine acupoints (TE 17, TE21, SI19, GB2, GB8, ST36, ST37, TE3 and TE9), two periauricular acupoints (TE17 and TE21), and four distal acupoints (TE3, TE9, ST36, and ST37) were selected. The treatment sessions were performed twice weekly for a total of eight sessions over 4 weeks. Outcomes were the tinnitus handicap inventory (THI) score and the loud and uncomfortable visual analogue scales (VAS). Demographic and clinical characteristics of all participants were compared between the groups upon admission using one-way analysis of variance (ANOVA). One-way ANOVA was used to evaluate the THI, VAS loud , and VAS uncomfortable scores. The least significant difference test was used as a post-hoc test. Thirty-nine subjects were eligible and their data were analyzed. No difference in THI and VAS loudness scores was observed in between groups. The VAS uncomfortable scores decreased significantly in MA and DE compared with those in PE. Within the group, all three treatments showed some effect on THI, VAS loudness scores and VAS uncomfortable scores after treatment except DE in THI. There was no statistically significant difference between systemic manual acupuncture, periauricular electroacupuncture and distal electroacupuncture in tinnitus. However, all three treatments had some effect on tinnitus within the group before and after treatment. Systemic manual acupuncture and distal electroacupuncture have some effect on VAS uncomfortable . KCT0001991 by CRIS (Clinical Research Information Service), 2016-8-1, retrospectively registered.
Wang, Fang; Cui, Shu; Wang, Fengmei; Li, Fenghui; Tang, Fei; Zhang, Xu; Gao, Yanying; Lv, Hongmin
2018-06-17
Determine the optimal scoring system for evaluation of 6-week bleeding-related mortality in liver cirrhosis patients with acute variceal bleeding (AVB). Prediction effects of six scoring systems, AIMS65 score, Glasgow-Blatchford (GBS) score, full Rockall (FRS) score, the model for end-stage liver disease (MELD), the MELD-Na model and the Child-Turcotte-Pugh (CTP) score were analyzed in this study. A total of 202 liver cirrhosis patients with AVB were enrolled between 1 January 2014, and 31 December 2014. All subjects were scored according to AIMS65, GBS, FRS, MELD, MELD-Na and CTP scoring systems on the first day of admission. The primary endpoint of the study was 6-week mortality. The prediction effect of these scoring systems for 6-week mortality was compared by ROC curve and the area under the curve (AUC). The scores of nonsurvival group evaluated by the AIMS65, GBS, FRS, MELD, MELD-Na and CTP (2.6 ± 1.1, 12.9 ± 2.7, 6.6 ± 1.8, 26.9 ± 6.5, 31.6 ± 9.3, 9.6 ± 2.2, respectively) were higher than those of the survival group (1.2 ± 1.1, 10.2 ± 3.4, 5.1 ± 1.6, 21.0 ± 6.4, 22.8 ± 8.2, 7.7 ± 2.0, respectively) (p < .01). The values of AUC and Youden index of AIMS65 and MELD-Na scoring systems [(0.808, 0.453) and (0.781, 0.516), respectively] were superior to those of MELD (0.761, 0.454), CTP (0.748, 0.399), FRS (0.738, 0.358) and GBS scoring systems (0.726, 0.370). AIMS65 and MELD-Na scoring systems are recommended for evaluation of 6-week bleeding-related mortality in liver cirrhosis patients with AVB.
Graphical method for comparative statistical study of vaccine potency tests.
Pay, T W; Hingley, P J
1984-03-01
Producers and consumers are interested in some of the intrinsic characteristics of vaccine potency assays for the comparative evaluation of suitable experimental design. A graphical method is developed which represents the precision of test results, the sensitivity of such results to changes in dosage, and the relevance of the results in the way they reflect the protection afforded in the host species. The graphs can be constructed from Producer's scores and Consumer's scores on each of the scales of test score, antigen dose and probability of protection against disease. A method for calculating these scores is suggested and illustrated for single and multiple component vaccines, for tests which do or do not employ a standard reference preparation, and for tests which employ quantitative or quantal systems of scoring.
Reliability of patient specific instrumentation in total knee arthroplasty.
Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David
2015-12-01
The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.
Pratt, M W; Diessner, R; Hunsberger, B; Pancer, S M; Savoy, K
1991-12-01
Four systems for analyzing thinking about 2 personal-life dilemmas, as discussed by 29 men and 35 women (ages 35-85), were compared. Kohlberg's (1976) moral judgment stages, Kegan's (1982) ego-development stages, Gilligan's (1982) moral orientation system, and Suedfeld and Tetlock's (1977) integrative complexity scoring were used. Subjects completed Kohlberg's (Colby & Kohlberg, 1987) standard moral judgment measure, a self-concept description, and several questionnaires. The Kohlberg, Kegan, and integrative complexity codings of the dilemmas were positively related to each other and to the standard Kohlberg moral stage scores. There were no age-group differences and few gender differences on the measures. However, education, role-taking skills, and greater sensitivity to age changes in the self positively predicted higher stage scores across maturity.
Hilton, C; Fisher, W; Lopez, A; Sanders, C
1997-09-01
To design and test a simple, easily modifiable system for calculating faculty productivity in teaching, research, administration, and patient care in which all areas of endeavor would be recognized and high productivity in one area would produce results similar to high productivity in another at the Louisiana State University School of Medicine in New Orleans. A relative-value and time-based system was designed in 1996 so that similar efforts in the four areas would produce similar scores, and a profile reflecting the authors' estimates of high productivity ("super faculty") was developed for each area. The activity profiles of 17 faculty members were used to test the system. "Super-faculty" scores in all areas were similar. The faculty members' mean scores were higher for teaching and research than for administration and patient care, and all four mean scores were substantially lower than the respective totals for the "super faculty". In each category the scores of those faculty members who scored above the mean in that category were used to calculate new mean scores. The mean scores for these faculty members were similar to those for the "super faculty" in teaching and research but were substantially lower for administration and patient care. When the mean total score of the eight faculty members predicted to have total scores below the group mean was compared with the mean total score of the nine faculty members predicted to have total scores above the group mean, the difference was significant (p < .0001). For the former, every score in each category was below the mean, with the exception of one faculty member's score in one category. Of the latter, eight had higher scores in teaching and four had higher scores in teaching and research combined. This system provides a quantitative method for the equal recognition of faculty productivity in a number of areas, and it may be useful as a starting point for other academic units exploring similar issues.
Hoeksema, Lisette; Los, Leonoor I
2016-01-01
We investigated the vision-related quality of life (VR-QOL) in patients with HLA-B27 associated anterior uveitis (AU). The study was conducted in 2012 at the ophthalmology department of the University Medical Center of Groningen. We included AU patients who were HLA-B27 positive and/or were diagnosed by a rheumatologist with an HLA-B27 associated systemic disease. Sixty-one of 123 (50%) adult patients participated. All patients filled-out the National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25), Beck Depression Inventory (BDI-II), social support lists and an additional questionnaire for gathering general information. Medical records were reviewed for clinical characteristics. Analyses were conducted on various patient and ocular characteristics. We compared our NEI VFQ-25 scores with those previously found in the literature. Our main outcome measures were VR-QOL scores and their associations with various general patient and ocular characteristics. We found that the NEI VFQ-25 mean overall composite score was 88.9±8.8, which is relatively high, but lower than that found in a normal working population. The mean general health score was 47.4±20.8, which is lower than in patients with other ocular diseases. Patients with a systemic disease scored significantly lower on general health and VR-QOL, compared to patients without a systemic disease. Patients with a depression (6/59 (10%)) frequently had ankylosing spondylitis (5/6 patients) and they scored significantly worse on VR-QOL. We concluded that patients with HLA-B27 associated AU have a relatively high VR-QOL. However, the presence of a systemic disease is associated with lower VR-QOL and general health scores. In addition, depression is associated with a lower VR-QOL.
Hoeksema, Lisette; Los, Leonoor I.
2016-01-01
We investigated the vision-related quality of life (VR-QOL) in patients with HLA-B27 associated anterior uveitis (AU). The study was conducted in 2012 at the ophthalmology department of the University Medical Center of Groningen. We included AU patients who were HLA-B27 positive and/or were diagnosed by a rheumatologist with an HLA-B27 associated systemic disease. Sixty-one of 123 (50%) adult patients participated. All patients filled-out the National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25), Beck Depression Inventory (BDI-II), social support lists and an additional questionnaire for gathering general information. Medical records were reviewed for clinical characteristics. Analyses were conducted on various patient and ocular characteristics. We compared our NEI VFQ-25 scores with those previously found in the literature. Our main outcome measures were VR-QOL scores and their associations with various general patient and ocular characteristics. We found that the NEI VFQ-25 mean overall composite score was 88.9±8.8, which is relatively high, but lower than that found in a normal working population. The mean general health score was 47.4±20.8, which is lower than in patients with other ocular diseases. Patients with a systemic disease scored significantly lower on general health and VR-QOL, compared to patients without a systemic disease. Patients with a depression (6/59 (10%)) frequently had ankylosing spondylitis (5/6 patients) and they scored significantly worse on VR-QOL. We concluded that patients with HLA-B27 associated AU have a relatively high VR-QOL. However, the presence of a systemic disease is associated with lower VR-QOL and general health scores. In addition, depression is associated with a lower VR-QOL. PMID:26808922
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
ERIC Educational Resources Information Center
Guenzler, April M.
2016-01-01
This study sought to identify correlations between constructs of teacher leadership, teacher efficacy, and teacher evaluation. Teacher perceptual data of support of teacher leadership, perceptual data on personal teacher efficacy, and teacher self-reported scores from the North Carolina Educator Evaluation System were gathered. The relationships…
SAT Scores, 2012-13: Wake County Public School System (WCPSS). Measuring Up. D&A Report No. 13.22
ERIC Educational Resources Information Center
Muli, Juliana; Gilleland, Kevin; McMillen, Brad
2014-01-01
As the ACT has become part of North Carolina's mandatory testing program, SAT participation in Wake County Public School System (WCPSS) and North Carolina has declined in recent years. However, SAT performance in WCPSS remains high compared to state and national averages. In 2012-13, students in WCPSS continued to score 50-60 points higher on the…
Yang, Hae Min; Jeon, Seong Woo; Jung, Jin Tae; Lee, Dong Wook; Ha, Chang Yoon; Park, Kyung Sik; Lee, Si Hyung; Yang, Chang Heon; Park, Jun Hyung; Park, Youn Sun
2016-01-01
The Glasgow-Blatchford score (GBS) and Rockall score (RS) are widely used to assess risk in patients with upper gastrointestinal bleeding (UGIB). We compared both scoring systems and evaluated their clinical usefulness. Between February 2011 and December 2013, 1584 patients with nonvariceal UGIB were included in the study. A prospective study was conducted to compare the performance of the GBS, pre-RS, and full RS. We compared the performance of these scores using receiver operating characteristic curves. For prediction of the need for hospital-based intervention, the GBS was similar to the full RS (area under the receiver operating characteristic curves [AUROC] 0.705 vs 0.727; P = 0.282) and superior to the pre-RS (AUROC 0.705 vs 0.601; P < 0.0001). In predicting death, the full RS was superior to the GBS (AUROC 0.758 vs 0.644; P = 0.0006) and similar to the pre-RS (AUROC 0.758 vs 0.754; P = 0.869). In predicting rebleeding, the full RS was superior to both GBS (AUROC 0.642 vs 0.585; P = 0.031) and pre-RS (AUROC 0.642 vs 0.593; P = 0.0003). Of 1584 patients, 13 (0.8%) scored 0 on the GBS. Therapeutic intervention was not performed in any of these patients. The GBS is more useful than the pre-RS for predicting the need for hospital-based intervention. A cutoff value of 0 for low-risk patients who might be suitable for outpatient management is useful. The full RS is helpful in predicting death. None of the systems accurately predict rebleeding with a low AUROC. ( cris.nih.go.kr/KCT0000514). © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Scoring and staging systems using cox linear regression modeling and recursive partitioning.
Lee, J W; Um, S H; Lee, J B; Mun, J; Cho, H
2006-01-01
Scoring and staging systems are used to determine the order and class of data according to predictors. Systems used for medical data, such as the Child-Turcotte-Pugh scoring and staging systems for ordering and classifying patients with liver disease, are often derived strictly from physicians' experience and intuition. We construct objective and data-based scoring/staging systems using statistical methods. We consider Cox linear regression modeling and recursive partitioning techniques for censored survival data. In particular, to obtain a target number of stages we propose cross-validation and amalgamation algorithms. We also propose an algorithm for constructing scoring and staging systems by integrating local Cox linear regression models into recursive partitioning, so that we can retain the merits of both methods such as superior predictive accuracy, ease of use, and detection of interactions between predictors. The staging system construction algorithms are compared by cross-validation evaluation of real data. The data-based cross-validation comparison shows that Cox linear regression modeling is somewhat better than recursive partitioning when there are only continuous predictors, while recursive partitioning is better when there are significant categorical predictors. The proposed local Cox linear recursive partitioning has better predictive accuracy than Cox linear modeling and simple recursive partitioning. This study indicates that integrating local linear modeling into recursive partitioning can significantly improve prediction accuracy in constructing scoring and staging systems.
Sanders, G D; Nease, R F; Owens, D K
2000-01-01
Local tailoring of clinical practice guidelines (CPGs) requires experts in medicine and evidence synthesis unavailable in many practice settings. The authors' computer-based system enables developers and users to create, disseminate, and tailor CPGs, using normative decision models (DMs). ALCHEMIST, a web-based system, analyzes a DM, creates a CPG in the form of an annotated algorithm, and displays for the guideline user the optimal strategy. ALCHEMIST'S interface enables remote users to tailor the guideline by changing underlying input variables and observing the new annotated algorithm that is developed automatically. In a pilot evaluation of the system, a DM was used to evaluate strategies for staging non-small-cell lung cancer. Subjects (n = 15) compared the automatically created CPG with published guidelines for this staging and critiqued both using a previously developed instrument to rate the CPGs' usability, accountability, and accuracy on a scale of 0 (worst) to 2 (best), with higher scores reflecting higher quality. The mean overall score for the ALCHEMIST CPG was 1.502, compared with the published-CPG score of 0.987 (p = 0.002). The ALCHEMIST CPG scores for usability, accountability, and accuracy were 1.683, 1.393, and 1.430, respectively; the published CPG scores were 1.192, 0.941, and 0.830 (each comparison p < 0.05). On a scale of 1 (worst) to 5 (best), users' mean ratings of ALCHEMIST'S ease of use, usefulness of content, and presentation format were 4.76, 3.98, and 4.64, respectively. The results demonstrate the feasibility of a web-based system that automatically analyzes a DM and creates a CPG as an annotated algorithm, enabling remote users to develop site-specific CPGs. In the pilot evaluation, the ALCHEMIST guidelines met established criteria for quality and compared favorably with national CPGs. The high usability and usefulness ratings suggest that such systems can be a good tool for guideline development.
Miranda, Dinis Reis; Nap, Raoul; de Rijk, Angelique; Schaufeli, Wilmar; Iapichino, Gaetano
2003-02-01
The instruments used for measuring nursing workload in the intensive care unit (e.g., Therapeutic Intervention Scoring System-28) are based on therapeutic interventions related to severity of illness. Many nursing activities are not necessarily related to severity of illness, and cost-effectiveness studies require the accurate evaluation of nursing activities. The aim of the study was to determine the nursing activities that best describe workload in the intensive care unit and to attribute weights to these activities so that the score describes average time consumption instead of severity of illness. To define by consensus a list of nursing activities, to determine the average time consumption of these activities by use of a 1-wk observational cross-sectional study, and to compare these results with those of the Therapeutic Intervention Scoring System-28. A total of 99 intensive care units in 15 countries. Consecutive admissions to the intensive care units. Daily recording of nursing activities at a patient level and random multimoment recording of these activities. A total of five new items and 14 subitems describing nursing activities in the intensive care unit (e.g., monitoring, care of relatives, administrative tasks) were added to the list of therapeutic interventions in Therapeutic Intervention Scoring System-28. Data from 2,041 patients (6,451 nursing days and 127,951 multimoment recordings) were analyzed. The new activities accounted for 60% of the average nursing time; the new scoring system (Nursing Activities Score) explained 81% of the nursing time (vs. 43% in Therapeutic Intervention Scoring System-28). The weights in the Therapeutic Intervention Scoring System-28 are not derived from the use of nursing time. Our study suggests that the Nursing Activities Score measures the consumption of nursing time in the intensive care unit. These results should be validated in independent databases.
Sway Area and Velocity Correlated With MobileMat Balance Error Scoring System (BESS) Scores.
Caccese, Jaclyn B; Buckley, Thomas A; Kaminski, Thomas W
2016-08-01
The Balance Error Scoring System (BESS) is often used for sport-related concussion balance assessment. However, moderate intratester and intertester reliability may cause low initial sensitivity, suggesting that a more objective balance assessment method is needed. The MobileMat BESS was designed for objective BESS scoring, but the outcome measures must be validated with reliable balance measures. Thus, the purpose of this investigation was to compare MobileMat BESS scores to linear and nonlinear measures of balance. Eighty-eight healthy collegiate student-athletes (age: 20.0 ± 1.4 y, height: 177.7 ± 10.7 cm, mass: 74.8 ± 13.7 kg) completed the MobileMat BESS. MobileMat BESS scores were compared with 95% area, sway velocity, approximate entropy, and sample entropy. MobileMat BESS scores were significantly correlated with 95% area for single-leg (r = .332) and tandem firm (r = .474), and double-leg foam (r = .660); and with sway velocity for single-leg (r = .406) and tandem firm (r = .601), and double-leg (r = .575) and single-leg foam (r = .434). MobileMat BESS scores were not correlated with approximate or sample entropy. MobileMat BESS scores were low to moderately correlated with linear measures, suggesting the ability to identify changes in the center of mass-center of pressure relationship, but not higher-order processing associated with nonlinear measures. These results suggest that the MobileMat BESS may be a clinically-useful tool that provides objective linear balance measures.
Al-Qahtani, Hamad Hadi; Alam, Mohammed Khurshid; Waheed, Muhammad
2017-02-01
To determine the predictability of harmless acute pancreatitis score (HAPS) in determining the severity of acute pancreatitis (AP) and compare it with Ranson's score. Prospective cohort study. King Saud Medical City, Riyadh, Kingdom of Saudi Arabia, between January 2012 and December 2015. All patients admitted with AP at King Saud Medical City, Riyadh, during 2012 - 2015 were studied prospectively. Patients were assessed by HAPS and Ranson's score. Predictability values of the two systems were analysed and compared. Out of 116 patients studied, 104 (89.6%) were HAPS positive and predicted to have mild disease. Pancreatitis was mild in 101 (87%) but severe in 3 (2.6%) patients who scored ≥ 3 Ranson's criteria. Among 12 HAPS negative patients, 10 scored ≥ 3 Ranson's criteria and developed severe pancreatitis while 2 (1.7%) with 2 positive Ranson's criteria developed mild pancreatitis. HAPS correctly predicted the disease severity in 101 (87%) patients, a sensitivity of 98% specificity of 77% and accuracy of 96%. Ranson's system predicted correctly in all but took 48 hours for assessment. Statistical analysis showed moderate agreement (Kappa = 0.776, p < 0.001), and positive relation (rs = 0.777, p < 0.001) between the two scores. HAPS is effective in rapid identification of patient who will run non-severe course of AP. Assessment can be completed within one hour from presentation. Ranson's score, although more accurate, takes 48 hours to complete.
Locating pairs of comparable study areas...new system developed
Raymond D. Ratliff; Jack N. Reppert
1966-01-01
A new system developed for locating pairs of comparable areas consists of three steps: (a) characterizing each of two areas according to 18 site factors and soil properties, (b) rating each pair of characteristics for comparability, and (c) rating the two areas for comparability by using the individual ratings as the basis. Two areas scoring 85 or more points out of a...
Hodgson, Tobias; Magrabi, Farah; Coiera, Enrico
2018-05-01
To conduct a usability study exploring the value of using speech recognition (SR) for clinical documentation tasks within an electronic health record (EHR) system. Thirty-five emergency department clinicians completed a system usability scale (SUS) questionnaire. The study was undertaken after participants undertook randomly allocated clinical documentation tasks using keyboard and mouse (KBM) or SR. SUS scores were analyzed and the results with KBM were compared to SR results. Significant difference in SUS scores between EHR system use with and without SR were observed (KBM 67, SR 61; P = 0.045; CI, 0.1 to 12.0). Nineteen of 35 participants scored higher for EHR with KBM, 11 higher for EHR with SR and 5 gave the same score for both. Factor analysis showed no significant difference in scores for the sub-element of usability (EHR with KBM 65, EHR with SR 62; P = 0.255; CI, -2.6 to 9.5). Scores for the sub-element of learnability were significantly different (KBM 72, SR 55; P < 0.001; CI, 9.8 to 23.5). A significant correlation was found between the perceived usability of the two system configurations (EHR with KBM or SR) and the efficiency of documentation (time to document) (P = 0.002; CI, 10.5 to -0.1) but not with safety (number of errors) (P = 0.90; CI, -2.3 to 2.6). SR was associated with significantly reduced overall usability scores, even though it is often positioned as ease of use technology. SR was perceived to impose larger costs in terms of learnability via training and support requirements for EHR based documentation when compared to using KBM. Lower usability scores were significantly associated with longer documentation times. The usability of EHR systems with any input modality is an area that requires continued development. The addition of an SR component to an EHR system may cause a significant reduction in terms of perceived usability by clinicians. Copyright © 2018 Elsevier B.V. All rights reserved.
Stoltz, Petronella; Manworren, Renee C B
Needle procedures, like venipuncture and intravenous (IV) catheter insertion, are recognized as a common cause of pain and fear for children in hospitals and emergency departments. The purpose of this study was to compare children's self-reported pain and fear related to IV insertion with administration of either the topical local anesthetic EMLA® or 1% buffered lidocaine delivered with the J-Tip Needleless Injection System® (J-Tip®). In this prospective, randomized trial, 150 consecutive pediatric patients 8 to 18years of age undergoing IV insertion were randomly assigned 1:1 to treatment group. Participants self-reported procedural pain using a Visual Analog Scale, and procedural fear using the Children's Fear Scale. Procedural pain scores were significantly lower in the EMLA® group (mean score 1.63+1.659) vs. the J-Tip® group (2.99±2.586; p<0.001). Post-procedure fear scores were significantly lower than pre-procedure fear scores in both treatment groups (p<0.002), but there was no difference in fear scores between the two treatment groups (p=0.314). EMLA® provided superior pain relief for IV insertion compared to J-Tip®. Although EMLA® use resulted in lower self-reported pain scores compared to J-Tip®, pain scores for both treatments were low and fear scores did not differ. When IV insertion can be delayed for 60-90min, EMLA® should be used. When a delay is contraindicated, J-Tip® may be a reasonable alternative to minimize procedural pain of IV insertion. Copyright © 2017 Elsevier Inc. All rights reserved.
Zeng, F F; Xue, W Q; Cao, W T; Wu, B H; Xie, H L; Fan, F; Zhu, H L; Chen, Y M
2014-08-01
This case-control study compared the associations of four widely used diet-quality scoring systems with the risk of hip fractures and assessed their utility in elderly Chinese. We found that individuals avoiding a low-quality diet have a lower risk of hip fractures in elderly Chinese. Few studies examined the associations of diet-quality scores on bone health, and no studies were available in Asians and compared their validity and utility in a study. We assessed the associations and utility of four widely used diet-quality scoring systems with the risk of hip fractures. A case-control study of 726 patients with hip fractures (diagnosed within 2 weeks) aged 55-80 years and 726 age- (within 3 years) and gender-matched controls was conducted in Guangdong, China (2009-2013). Dietary intake was assessed using a 79-item food frequency questionnaire with face-to-face interviews, and the Healthy Eating Index-2005 (HEI-2005, 12 items), the alternate Healthy Eating Index (aHEI, 8 items), the Diet Quality Index-International (DQI-I, 17 items), and the alternate Mediterranean Diet Score (aMed, 9 items) (the simplest one) were calculated. All greater values of the diet-quality scores were significantly associated with a similar decreased risk of hip fractures (all p trends <0.001). The multivariate-adjusted odds ratios (ORs) and 95% confidential intervals (95% CIs) comparing the extreme groups of diet-quality scores were 0.29 (0.18, 0.46) (HEI-2005), 0.20 (0.12, 0.33) (aHEI), 0.25 (0.16, 0.39) (DQI-I), and 0.28 (0.18, 0.43) (aMed) in total subjects; and the corresponding ORs ranged from 0.04 to 0.27 for men and from 0.26 to 0.44 for women (all p trends <0.05), respectively. Avoiding a low-quality diet is associated with a lower risk of hip fractures, and the aMed score is the best scoring system due to its equivalent performance and simplicity for the user.
Upper Gastrointestinal Hemorrhage: Development of the Severity Score.
Chaikitamnuaychok, Rangson; Patumanond, Jayanton
2012-12-01
Emergency endoscopy for every patient with upper gastrointestinal hemorrhage is not possible in many medical centers. Simple guidelines to select patients for emergency endoscopy are lacking. The aim of the present report is to develop a simple scoring system to classify upper gastrointestinal hemorrhage (UGIH) severity based on patient clinical profiles at the emergency departments. Retrospective data of patients with UGIH in a university affiliated hospital were analyzed. Patients were criterion-classified into 3 severity levels: mild, moderate and severe. Clinical and laboratory information were compared among the 3 groups. Significant parameters were selected as indicators of severity. Coefficients of significant multivariable parameters were transformed into item scores, which added up as individual severity scores. The scores were used to classify patients into 3 urgency levels: non-urgent, urgent and emergent groups. Score-classification and criterion-classification were compared. Significant parameters in the model were age ≥ 60 years, pulse rate ≥ 100/min, systolic blood pressure < 100 mmHg, hemoglobin < 10 g/dL, blood urea nitrogen ≥ 35 mg/dL, presence of cirrhosis and hepatic failure. The score ranged from 0 to 27, and classifying patients into 3 urgency groups: non-urgent (score < 4, n = 215, 21.2%), urgent (score 4 - 16, n = 677, 66.9%) and emergent (score > 16, n = 121, 11.9%). The score correctly classified 81.4% of the patients into their original (criterion-classified) severity groups. Under-estimation (7.5%) and over-estimation (11.1%) were clinically acceptable. Our UGIH severity scoring system classified patients into 3 urgency groups: non-urgent, urgent and emergent, with clinically acceptable small number of under- and over-estimations. Its discriminative ability and precision should be validated before adopting into clinical practice.
Xiong, Qinmei; Chen, Sisi; Senoo, Keitaro; Proietti, Marco; Hong, Kui; Lip, Gregory Y H
2015-09-15
Both the CHADS2 and CHA2DS2-VASc scores are well-validated in Western populations for predicting risk of stroke among patients with atrial fibrillation (AF). There is some uncertainty as to which risk score is best to guide optimal anticoagulant therapy among Asian populations with AF. A systemic literature search of Cochrane library, Scopus, and PubMed databases was conducted using search terms: atrial fibrillation, CHADS2 and CHA2DS2-VASc. Stroke/thromboembolism (TE) outcome events at low, moderate, and high risk groups were compared in relation to both scores. Statistical analyses were performed using Revman 5.3 software. 493 records were retrieved, of which 6 cohort studies focusing on patients from Asian regions were finally appraised and included. Absolute event rates were usually lower when patients were categorized as CHA2DS2-VASc of 0-1, rather than CHADS2 of 0-1, respectively. Meta-analysis revealed that when compared with the CHA2DS2-VASc score, there was a 1.71-fold elevated risk of stroke when patients were stratified as 'low risk' using a CHADS2 score = 0, or a 1.40-fold increase with a CHADS2 score = 1. A 1.19-fold elevated event rate was observed among CHADS2 score ≥ 2 compared to CHA2DS2-VASc, but the total stroke/TE events were numerically higher in patients categorized as CHA2DS2-VASc ≥ 2. The CHA2DS2-VASc score is superior to the CHADS2 score in identifying 'low risk' East Asian AF patients. Rather than a categorical approach, Asian guidelines should adopt a 2 step approach, by initially identifying the truly low risk patients, following which effective stroke prevention can be offered to those with ≥ 1 additional stroke risk factors. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Use of injectable promethazine to decrease symptom scores of Space Motion Sickness
NASA Technical Reports Server (NTRS)
Beck, B. G.; Nicogossian, A. E.
1992-01-01
Space motion sickness (SMS) has been a problem affecting approximately 74 percent of first time shuttle flyers. Promethazine injections have been used for 29 cases of SMS to decrease the severity of their illness. Although reported to be effective in reducing symptoms in 27 of the 29 cases, there has been no proof of its efficacy. Methods: Retrospective analysis of medical debriefs examining the symptom scores for nausea, vomiting, decreased appetite, and stomach awareness were performed. Each symptom is rated on a mild = 1, moderate = 2, severe = 3 system for each flight day. Crewmember scores for the first three flight days on an initial flight in which injectable promethazine had not been used were compared to scores in a later flight in which the promethazine was utilized. Scores were also compared in a similar group of crewmembers who did not use promethazine. Results: There was a decrease in median scores for all symptoms except nausea, however, it was significant (p = 0.14) only for the vomiting scores. This significant decrease was not seen in the control group. Conclusions: Injectable promethazine has been associated with a significant decrease in vomiting compared to earlier flights in which injectable promethazine was not used.
Design Patterns Application in the ERP Systems Improvements
NASA Astrophysics Data System (ADS)
Jovičić, Bojan; Vlajić, Siniša
Design patterns application have long been present in software engineering. The same is true for ERP systems in business software. Is it possible that ERP systems do not have a good maintenance score? We have found out that there is room for maintenance improvement and that it is possible to improve ERP systems using design patterns. We have conducted comparative analysis of ease of maintenance of the ERP systems. The results show that the average score for our questions is 64%, with most answers for ERP systems like SAP, Oracle EBS, Dynamics AX. We found that 59% of ERP system developer users are not familiar with design patterns. Based on this research, we have chosen Dynamics AX as the ERP system for examination of design patterns improvement possibilities. We used software metrics to measure improvement possibility. We found that we could increase the Conditional Complexity score 17-fold by introducing design patterns.
Hwang, Sejin; Jeon, Seong Woo; Kwon, Joong Goo; Lee, Dong Wook; Ha, Chang Yoon; Cho, Kwang Bum; Jang, ByungIk; Park, Jung Bae; Park, Youn Sun
2016-07-01
Although the mortality rates for non-variceal upper gastrointestinal bleeding (NVUGIB) have recently decreased, it remains a significant medical problem. The main aim of this prospective multicenter database study was to construct a clinically useful predictive scoring system by using our predictors and compare its prognostic accuracy with that of the Rockall scoring system. Data were collected from consecutive patients with NVUGIB. Logistic regression analysis was performed to identify the independent predictors of 30-day mortality. Each independent predictor was assigned an integral point proportional to the odds ratio (OR) and we used the area under the curve to compare the discrimination ability between the new predictive model and the Rockall score. The independent predictors of mortality included age >65 years [OR 2.627; 95 % confidence interval (CI) 1.298-5.318], hemodynamic instability (OR 2.217; 95 % CI 1.069-4.597), serum blood urea nitrogen level >40 mg/dL (OR 1.895; 95 % CI 1.029-3.490), active bleeding at endoscopy (OR 2.434; 95 % CI 1.283-4.616), transfusions (OR 3.811; 95 % CI 1.640-8.857), comorbidities (OR 3.481; 95 % CI 1.405-8.624), and rebleeding (OR 10.581; 95 % CI 5.590-20.030). The new predictive model showed a high discrimination capability and was significantly superior to the Rockall score in predicting the risk of death (OR 0.837;95 % CI 0.818-0.855 vs. 0.761; 0.739-0.782; P = 0.0123). The new predictive score was significantly more accurate than the Rockall score in predicting death in NVUGIB patients. We need to prospectively validate the accuracy of this score for predicting mortality in NVUGIB patients.
Almasi, Mostafa; Ghasemi, Faeze; Chardoli, Mojtaba
2016-01-01
Background. The ABCD2 score is now identified as a useful clinical prediction rule to determine the risk for stroke in the days following brain ischemic attacks. Aim. The present study aimed to introduce a new scoring system named “ABCD2F” and compare its value with the previous ABCD2 system to predict recurrent ischemic stroke within 90 days of the initial cerebrovascular accident (CVA). Methods. 138 consecutive patients with the final diagnosis of ischemic CVA or TIAs who referred to emergency ward of Rasoul-e-Akram general hospital in Tehran from September 2012 to December 2013 were eligible. By adding a new score in the presence of atrial fibrillation to ABCD2 system, the new scoring system as ABCD2F was introduced and the risk stratification was done again on this new system. Results. The area under the curve for ABCD2 was 0.434 and for ABCD2F it was 0.452 indicating low value of both systems for assessing recurrence of stroke within 90 days of primary event. Multivariable logistic regression analysis showed that none of the baseline factors could predict 90-day recurrent stroke. Conclusion. ABCD2 and/or atrial fibrillation are not good scoring candidates for assessing the risk of recurrent stroke within first 90 days. PMID:27642521
Fife, Caroline E; Walker, David; Farrow, Wade; Otto, Gordon
2007-01-01
Outpatient wound center facility reimbursement for Medicare beneficiaries can be a challenge to determine and obtain. To compare methods of calculating facility service levels for outpatient wound centers and to demonstrate the advantages of an acuity-based billing system (one that incorporates components of facility work that is non-reimbursable by procedure codes and that represents an activity-based costing approach to medical billing), a retrospective study of 5,098 patient encounters contained in a wound care-specific electronic medical record database was conducted. Approximately 500 patient visits to the outpatient wound center of a Texas regional hospital between April 2003 and November 2004 were categorized by service level in documentation and facility management software. Visits previously billed using a time-based system were compared to the Centers for Medicare and Medicaid Services' proposed three-tiered wound size-based system. The time-based system also was compared to an acuity-based scoring system. The Pearson correlation coefficient between billed level of service by time and estimated level of service by acuity was 0.442 and the majority of follow-up visits were billed as Level 3 and above (on a time level of 1 to 5) , confirming that time is not a surrogate for actual work performed. Wound size also was found to be unrelated to service level (Pearson correlation = 0.017) and 97% of wound areas were < 100 cm2. The acuity-based scoring system produced a near-normal distribution of results, producing more mid-range billings than extremes; no other method produced this distribution. Hospital-based outpatient wound centers should develop, review, and refine acuity score-based models on which to determine billed level of service.
MARK’s Quadrant scoring system: a symptom-based targeted screening tool for gastric cancer
Tata, Mahadevan D.; Gurunathan, Ramesh; Palayan, Kandasami
2014-01-01
Background Gastric cancer is notably one of the leading causes of cancer-related death in the world. In Malaysia, these patients present in the advanced stage, thus narrowing the treatment options and making the surgery nearly impossible for successful curative resection. Failure to identify high-risk patients and delay in diagnostic endoscope procedure contributed to the delay in diagnosis. The aim of the study was to develop and validate a scoring system (MARK’s Quadrant) which can identify symptomatic patients who are at risk for gastric cancer. Methods A 3-phase approach was undertaken: Phase 1: development of the weighted scoring system; Phase 2: estimating positive predicting value of MARK’s Quadrant; and Phase 3: a) testing the validity of MARK’s Quadrant in an open-access endoscope system; and b) comparing its usefulness compared to conventional referral system. Results In phases 1 and 2, MARK’s Quadrant with weighted symptoms was developed. The sensitivity of MARK’s Quadrant is 88% and the specificity is 45.5% to detect cancerous and precancerous lesions of gastric. This was confirmed by the prospective data from phase 3 of this study where the diagnostic yield of MARK’s Quadrant to detect any pathological lesion was 95.2%. This score has a high accuracy efficiency of 75%, hence comparing to routine referral system it has an odds ratio (95%CI) of 10.98 (4.63-26.00), 6.71 (4.46-10.09) and 0.95 (0.06-0.15) (P<0.001 respectively) for cancer, precancerous lesion and benign lesion diagnosis respectively. Conclusion MARK’s Quadrant is a useful tool to detect early gastric cancer among symptomatic patients in a low incidence region. PMID:24714557
Comparison of ISS, NISS, and RTS score as predictor of mortality in pediatric fall.
Soni, Kapil Dev; Mahindrakar, Santosh; Gupta, Amit; Kumar, Subodh; Sagar, Sushma; Jhakal, Ashish
2017-01-01
Studies to identify an ideal trauma score tool representing prediction of outcomes of the pediatric fall patient remains elusive. Our study was undertaken to identify better predictor of mortality in the pediatric fall patients. Data was retrieved from prospectively maintained trauma registry project at level 1 trauma center developed as part of Multicentric Project-Towards Improving Trauma Care Outcomes (TITCO) in India. Single center data retrieved from a prospectively maintained trauma registry at a level 1 trauma center, New Delhi, for a period ranging from 1 October 2013 to 17 February 2015 was evaluated. Standard anatomic scores Injury Severity Score (ISS) and New Injury Severity Score (NISS) were compared with physiologic score Revised Trauma Score (RTS) using receiver operating curve (ROC). Heart rate and RTS had a statistical difference among the survivors to nonsurvivors. ISS, NISS, and RTS were having 50, 50, and 86% of area under the curve on ROCs, and RTS was statistically significant among them. Physiologically based trauma score systems (RTS) are much better predictors of inhospital mortality in comparison to anatomical based scoring systems (ISS and NISS) for unintentional pediatric falls.
Plaque reduction over time of an integrated oral hygiene system.
Nunn, Martha E; Ruhlman, C Douglas; Mallatt, Philip R; Rodriguez, Sally M; Ortblad, Katherine M
2004-10-01
This article compares the efficacy of a prototype integrated system (the IntelliClean System from Sonicare and Crest) in the reduction of supragingival plaque to that of a manual toothbrush and conventional toothpaste. The integrated system was compared to a manual toothbrush with conventional toothpaste in a randomized, single-blinded, parallel, 4-week, controlled clinical trial with 100 subjects randomized to each treatment group. There was a low dropout rate, with 89 subjects in the manual toothbrush group (11% loss to follow-up) and 93 subjects in the integrated system group (7% loss to follow-up) completing the study. The Turesky modification of the Quigley and Hein Plaque Index was used to assess full-mouth plaque scores for each subject. Prebrushing plaque scores were obtained at baseline and at 4 weeks after 14 to 20 hours of plaque accumulation. A survey also was conducted at the conclusion of the study to determine the attitude toward the two oral hygiene systems. The integrated system was found to significantly reduce overall and interproximal prebrushing plaque scores over 4 weeks, both by 8.6%, demonstrating statistically significant superiority in overall plaque reduction (P = .002) and interproximal plaque reduction (P < .001) compared to the manual toothbrush with conventional toothpaste, which showed no significant reduction in either overall plaque or interproximal plaque. This study demonstrates that the IntelliClean System from Sonicare and Crest is superior to a manual toothbrush with conventional toothpaste in reducing overall plaque and interproximal plaque over time.
Comparing usability testing outcomes and functions of six electronic nursing record systems.
Cho, Insook; Kim, Eunman; Choi, Woan Heui; Staggers, Nancy
2016-04-01
This study examined the usability of six differing electronic nursing record (ENR) systems on the efficiency, proficiency and available functions for documenting nursing care and subsequently compared the results to nurses' perceived satisfaction from a previous study. The six hospitals had different ENR systems, all with narrative nursing notes in use for more than three years. Stratified by type of nursing unit, 54 staff nurses were digitally recorded during on-site usability testing by employing validated patient care scenarios and think-aloud protocols. The time to complete specific tasks was also measured. Qualitative performance data were converted into scores on efficiency (relevancy), proficiency (accuracy), and a competency index using scoring schemes described by McGuire and Babbott. Six nurse managers and the researchers completed assessments of available ENR functions and examined computerized nursing process components including the linkages among them. For the usability test, participants' mean efficiency score was 94.2% (95% CI, 91.4-96.9%). The mean proficiency was 60.6% (95% CI, 54.3-66.8%), and the mean competency index was 59.5% (95% CI, 52.9-66.0). Efficiency scores were significantly different across ENRs as was the time to complete tasks, ranging from 226.3 to 457.2s (χ(2)=12.3, P=0.031; χ(2)=11.2, P=0.048). No significant differences were seen for proficiency scores. The coverage of the various ENRs' nursing process ranged from 67% to 100%, but only two systems had complete integration of nursing components. Two systems with high efficiency and proficiency scores had much lower usability test scores and perceived user satisfaction along with more complex navigation patterns. In terms of system usability and functions, different levels of sophistication of and interaction performance with ENR systems exist in practice. This suggests that ENRs may have variable impacts on clinical outcomes and care quality. Future studies are needed to explore ENR impact on nursing care quality, efficiency, and safety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Tarr, Robert; Hsu, Dan; Kulcsar, Zsolt; Bonvin, Christophe; Rufenacht, Daniel; Alfke, Karsten; Stingele, Robert; Jansen, Olav; Frei, Donald; Bellon, Richard; Madison, Michael; Struffert, Tobias; Dorfler, Arnd; Grunwald, Iris Q; Reith, Wolfgang; Haass, Anton
2010-12-01
The purpose of this study was to assess the initial post-market experience of the device and how it is compared with the Penumbra Pivotal trial used to support the 510k application. A retrospective case review of 157 consecutive patients treated with the Penumbra system at seven international centers was performed. Primary endpoints were revascularization of the target vessel (TIMI score of 2 or 3), good functional outcome as defined by a modified Rankin scale (mRS) score of ≤2 and incidence of procedural serious adverse events. Results were compared with those of the Penumbra pivotal trial. A total of 157 vessels were treated. Mean baseline values at enrollment were: age 65 years, NIHSS score 16. After use of the Penumbra system, 87% of the treated vessels were revascularized to TIMI 2 (54%) or 3 (33%) as compared with 82% reported in the Pivotal trial. Nine procedural serious adverse events were reported in 157 patients (5.7%). All-cause mortality was 20% (32/157), and 41% had a mRS of ≤2 at 90-day follow-up as compared with only 25% in the Pivotal trial. Patients who were successfully revascularized by the Penumbra system had significantly better outcomes than those who were not. Initial post-market experience of the Penumbra system revealed that the revascularization rate and safety profile of the device are comparable to those reported in the Pivotal trial. However, the proportion of patients who had good functional outcome was higher than expected.
Deall, Ciara E; Kornmann, Nirvana S S; Bella, Husam; Wallis, Katy L; Hardwicke, Joseph T; Su, Ting-Li; Richard, Bruce M
2016-10-01
High-quality aesthetic outcomes are of paramount importance to children growing up after cleft lip and palate surgery. Establishing a validated and reliable assessment tool for cleft professionals and families will facilitate cleft units, surgeons, techniques, and protocols to be audited and compared with greater confidence. This study used exemplar images across a five-point aesthetic scale, identified in a pilot project, to score lips and noses as separate units and compared these human scores with computer-based SymNose symmetry scores. Forty-five assessors (17 cleft surgeons nationally and 28 other cleft professionals from the UK South West Tri-centre units), scored 25 standardized photographs, uploaded randomly onto a Web-based platform, twice. Each photograph was shown in three forms: lip and nose together, and separately cropped images of nose only and lip only. The same images were analyzed using the SymNose software program. Scoring lips gave the best intrarater and interrater reliabilities. Nose scores were more variable. Lip scoring associated most closely with the whole-image score. SymNose ranking of the lip images related highly to the same ranking by humans (p = 0.001). The exemplar images maintained their established previous ranking. Images illustrating the aesthetic outcome grades are confirmed. The lip score is reliable and seems to dominate in the whole-image score. Noses are much harder to score reliably. It appears that SymNose can score lip images very effectively by symmetry. Further use of SymNose will be investigated, and families of children with cleft will trial the scoring system. Therapeutic, III.
A Genomic Score Prognostic of Outcome in Trauma Patients
Warren, H Shaw; Elson, Constance M; Hayden, Douglas L; Schoenfeld, David A; Cobb, J Perren; Maier, Ronald V; Moldawer, Lyle L; Moore, Ernest E; Harbrecht, Brian G; Pelak, Kimberly; Cuschieri, Joseph; Herndon, David N; Jeschke, Marc G; Finnerty, Celeste C; Brownstein, Bernard H; Hennessy, Laura; Mason, Philip H; Tompkins, Ronald G
2009-01-01
Traumatic injuries frequently lead to infection, organ failure, and death. Health care providers rely on several injury scoring systems to quantify the extent of injury and to help predict clinical outcome. Physiological, anatomical, and clinical laboratory analytic scoring systems (Acute Physiology and Chronic Health Evaluation [APACHE], Injury Severity Score [ISS]) are utilized, with limited success, to predict outcome following injury. The recent development of techniques for measuring the expression level of all of a person’s genes simultaneously may make it possible to develop an injury scoring system based on the degree of gene activation. We hypothesized that a peripheral blood leukocyte gene expression score could predict outcome, including multiple organ failure, following severe blunt trauma. To test such a scoring system, we measured gene expression of peripheral blood leukocytes from patients within 12 h of traumatic injury. cRNA derived from whole blood leukocytes obtained within 12 h of injury provided gene expression data for the entire genome that were used to create a composite gene expression score for each patient. Total blood leukocytes were chosen because they are active during inflammation, which is reflective of poor outcome. The gene expression score combines the activation levels of all the genes into a single number which compares the patient’s gene expression to the average gene expression in uninjured volunteers. Expression profiles from healthy volunteers were averaged to create a reference gene expression profile which was used to compute a difference from reference (DFR) score for each patient. This score described the overall genomic response of patients within the first 12 h following severe blunt trauma. Regression models were used to compare the association of the DFR, APACHE, and ISS scores with outcome. We hypothesized that patients with a total gene response more different from uninjured volunteers would tend to have poorer outcome than those more similar. Our data show that for measures of poor outcome, such as infections, organ failures, and length of hospital stay, this is correct. DFR scores were associated significantly with adverse outcome, including multiple organ failure, duration of ventilation, length of hospital stay, and infection rate. The association remained significant after adjustment for injury severity as measured by APACHE or ISS. A single score representing changes in gene expression in peripheral blood leukocytes within hours of severe blunt injury is associated with adverse clinical outcomes that develop later in the hospital course. Assessment of genome-wide gene expression provides useful clinical information that is different from that provided by currently utilized anatomic or physiologic scores. PMID:19593405
Establishment and Validation of GV-SAPS II Scoring System for Non-Diabetic Critically Ill Patients
Liu, Wen-Yue; Lin, Shi-Gang; Zhu, Gui-Qi; Poucke, Sven Van; Braddock, Martin; Zhang, Zhongheng; Mao, Zhi; Shen, Fei-Xia
2016-01-01
Background and Aims Recently, glucose variability (GV) has been reported as an independent risk factor for mortality in non-diabetic critically ill patients. However, GV is not incorporated in any severity scoring system for critically ill patients currently. The aim of this study was to establish and validate a modified Simplified Acute Physiology Score II scoring system (SAPS II), integrated with GV parameters and named GV-SAPS II, specifically for non-diabetic critically ill patients to predict short-term and long-term mortality. Methods Training and validation cohorts were exacted from the Multiparameter Intelligent Monitoring in Intensive Care database III version 1.3 (MIMIC-III v1.3). The GV-SAPS II score was constructed by Cox proportional hazard regression analysis and compared with the original SAPS II, Sepsis-related Organ Failure Assessment Score (SOFA) and Elixhauser scoring systems using area under the curve of the receiver operator characteristic (auROC) curve. Results 4,895 and 5,048 eligible individuals were included in the training and validation cohorts, respectively. The GV-SAPS II score was established with four independent risk factors, including hyperglycemia, hypoglycemia, standard deviation of blood glucose levels (GluSD), and SAPS II score. In the validation cohort, the auROC values of the new scoring system were 0.824 (95% CI: 0.813–0.834, P< 0.001) and 0.738 (95% CI: 0.725–0.750, P< 0.001), respectively for 30 days and 9 months, which were significantly higher than other models used in our study (all P < 0.001). Moreover, Kaplan-Meier plots demonstrated significantly worse outcomes in higher GV-SAPS II score groups both for 30-day and 9-month mortality endpoints (all P< 0.001). Conclusions We established and validated a modified prognostic scoring system that integrated glucose variability for non-diabetic critically ill patients, named GV-SAPS II. It demonstrated a superior prognostic capability and may be an optimal scoring system for prognostic evaluation in this patient group. PMID:27824941
Stravodimou, Aristea; Tzelepi, Vassiliki; Papadaki, Helen; Mouzaki, Athanasia; Georgiou, Sophia; Melachrinou, Maria; Kourea, Eleni P
2018-05-01
Tumor infiltrating lymphocytes (TILs) represent important regulators of carcinogenesis. Cutaneous invasive squamous cell carcinoma (inSCC) develops through precursor lesions, namely in situ squamous cell carcinoma (isSCC) and actinic keratosis (AK), representing a natural model of carcinogenesis. The study evaluates TIL subpopulations in inSCC and its precursors by comparing 2 semiquantitative scoring systems, and assesses the presence of regulatory T-cells (Tregs) in these lesions. Paraffin sections from 33 cases of AK, 19 isSCCs and 34 inSCCs with adjacent precursor lesions or normal skin (NS) were immunostained for CD3, CD4, CD8 and Foxp3. TIL subgroups were evaluated by the semiquantitative Klintrup-Mäkinen (K-M) score, and by a more detailed modification of this system. Treg counts were assessed by image analysis quantification. An increase of all TIL subpolulations from precursor lesions toward inSCC was shown by both scoring systems. Treg counts progressively increased from NS to AK and isSCC, but decreased in inSCC. Tregs were more numerous in pT2 and around indolent inSCCs compared to T1 and aggressive subtypes. T-cells and cytotoxic T-cells progressively increase in cutaneous squamous cell carcinogenesis, while Treg counts diminish in inSCC. The K-M score is an appropriate, easily applicable TIL scoring system in cutaneous inSCC. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The Introduction of Adult Appendicitis Score Reduced Negative Appendectomy Rate.
Sammalkorpi, H E; Mentula, P; Savolainen, H; Leppäniemi, A
2017-09-01
Implementation of a clinical risk score into diagnostics of acute appendicitis may provide accurate diagnosis with selective use of imaging studies. The aim of this study was to prospectively validate recently described diagnostic scoring system, Adult Appendicitis Score, and evaluate its effects on negative appendectomy rate. Adult Appendicitis Score stratifies patients into three groups: high, intermediate, and low risk of appendicitis. The score was implemented in diagnostics of adult patients suspected of acute appendicitis in two university hospitals. We analyzed the effects of Adult Appendicitis Score on diagnostic accuracy, imaging studies, and treatment. The study population was compared with a reference population of 829 patients suspected of acute appendicitis originally enrolled for the study of construction of the Adult Appendicitis Score. This study enrolled 908 patients of whom 432 (48%) had appendicitis. The score stratified 49% of all appendicitis patients into high-risk group with specificity of 93.3%. In the low-risk group, prevalence of appendicitis was 7%. The histologically confirmed negative appendectomy rate decreased from 18.2% to 8.7%, p<0.001, compared to the original dataset. Adult Appendicitis Score is a reliable tool for stratification of patients into selective imaging, which results in low negative appendectomy rate.
A comparison of KABCO and AIS injury severity metrics using CODES linked data.
Burch, Cynthia; Cook, Lawrence; Dischinger, Patricia
2014-01-01
The research objective is to compare the consistency of distributions between crash assigned (KABCO) and hospital assigned (Abbreviated Injury Scale, AIS) injury severity scoring systems for 2 states. The hypothesis is that AIS scores will be more consistent between the 2 studied states (Maryland and Utah) than KABCO. The analysis involved Crash Outcome Data Evaluation System (CODES) data from 2 states, Maryland and Utah, for years 2006-2008. Crash report and hospital inpatient data were linked probabilistically and International Classification of Diseases (CMS 2013) codes from hospital records were translated into AIS codes. KABCO scores from police crash reports were compared to those AIS scores within and between the 2 study states. Maryland appears to have the more severe crash report KABCO scoring for injured crash participants, with close to 50 percent of all injured persons being coded as a level B or worse, and Utah observes approximately 40 percent in this group. When analyzing AIS scores, some fluctuation was seen within states over time, but the distribution of MAIS is much more comparable between states. Maryland had approximately 85 percent of hospitalized injured cases coded as MAIS = 1 or minor. In Utah this percentage was close to 80 percent for all 3 years. This is quite different from the KABCO distributions, where Maryland had a smaller percentage of cases in the lowest injury severity category as compared to Utah. This analysis examines the distribution of 2 injury severity metrics different in both design and collection and found that both classifications are consistent within each state from 2006 to 2008. However, the distribution of both KABCO and Maximum Abbreviated Injury Scale (MAIS) varies between the states. MAIS was found to be more consistent between states than KABCO.
Kim, Bia Z; Patel, Dipika V; McKelvie, James; Sherwin, Trevor; McGhee, Charles N J
2017-09-01
To assess the effect of preoperative risk stratification for phacoemulsification surgery on intraoperative complications in a teaching hospital. Prospective cohort study. Prospective assessment of consecutive phacoemulsification cases (N = 500) enabled calculation of a risk score (M-score of 0-8) using a risk stratification system. M-scores of >3 were allocated to senior surgeons. All surgeries were performed in a public teaching hospital setting, Auckland, New Zealand, in early 2016. Postoperatively, data were reviewed for complications and corrected distance visual acuity (CDVA). Results were compared to a prospective study (N = 500, phase 1) performed prior to formal introduction of risk stratification. Intraoperative complications increased with increasing M-scores (P = .044). Median M-score for complicated cases was higher (P = .022). Odds ratio (OR) for a complication increased 1.269 per unit increase in M-score (95% confidence interval [CI] 1.007-1.599, P = .043). Overall rate of any intraoperative complication was 5.0%. Intraoperative complication rates decreased from 8.4% to 5.0% (OR = 0.576, P = .043) comparing phase 1 and phase 2 (formal introduction of risk stratification). The severity of complications also reduced. A significant decrease in complications for M = 0 (ie, minimal risk cases) was also identified comparing the current study (3.1%) to phase 1 (7.2%), P = .034. There was no change in postoperative complication risks (OR 0.812, P = .434) or in mean postoperative CDVA (20/30, P = .484) comparing current with phase 1 outcomes. A simple preoperative risk stratification system, based on standard patient information gathered at preoperative consultation, appears to reduce intraoperative complications and support safer surgical training by appropriate allocation of higher-risk cases. Copyright © 2017 Elsevier Inc. All rights reserved.
Modified TIME-H: a simplified scoring system for chronic wound management.
Lim, K; Free, B; Sinha, S
2015-09-01
Chronic wound assessment requires a systematic approach in order to guide management and improve prognostication. Following a pilot study using the original TIME-H scoring system in chronic wound management, modifications were suggested leading to the development of the Modified TIME-H scoring system. This study investigates the feasibility and reliability of chronic wound prognostication applying the Modified TIME-H score. Patients referred to the hospital's outpatient wound clinic over a 9-month period were categorised into one of three predicted outcome categories based on their Modified TIME-H score. This study shows a higher proportion of patients in the certain healing category achieved healed wounds, with a higher rate of reduction in wound size, when compared with the other categories. The three categories defined in this study are certain healing, uncertain healing and difficult healing. The Modified TIME-H score could be a useful tool for assessment, patient-centred management and prognostication of chronic wounds in clinical practice and requires further validation from other institutions. The authors have no conflict of interest to declare.
Howells, N R; Dunne, N; Reddy, S
2006-07-01
To report the casualty profile of the major incident at the Royal Berkshire Hospital, Reading, following the Ufton Nervet Train crash, November 2004. To make further proposals regarding major incident reporting and implementation of trauma-scoring systems. Retrospective analysis of emergency department and hospital notes. Calculation of index Injury Severity Score (ISS) and Trauma and Injury Severity Score (TRISS) in all patients. Of 61 casualties, the majority (74%) were seen in the minors area of our emergency department with a mixture of blunt impact and penetrating glass injuries. One died and 16 were admitted. 10% had an ISS >16. All surviving patients had a TRISS predicted probability of survival >90%. We propose mandatory major incident reporting within 6 months of a major incident to aid development of a national database. As previously proposed, this will aid education and facilitate future major incident planning. We further propose the widespread use of trauma scoring systems to facilitate comparative analysis between major incidents, perhaps extrapolating this to develop a major incident score.
Rossi, Silmara; Sánchez-Sarmiento, Angélica María; Vanstreels, Ralph Eric Thijl; dos Santos, Robson Guimarães; Prioste, Fabiola Eloisa Setim; Gattamorta, Marco Aurélio; Grisi-Filho, José Henrique Hildebrand; Matushima, Eliana Reiko
2016-01-01
Fibropapillomatosis (FP) is a neoplastic disease that affects marine turtles worldwide, especially green sea turtles (Chelonia mydas). FP tumors can develop on the body surface of marine turtles and also internally in the oral cavity and viscera. Depending on their quantity, size and anatomical distribution, these tumors can interfere with hydrodynamics and the ability to feed, hence scoring systems have been proposed in an attempt to quantify the clinical manifestation of FP. In order to establish a new scoring system adapted to geographic regions, we examined 214 juvenile green sea turtles with FP caught or rescued at Brazilian feeding areas, counted their 7466 tumors and classified them in relation to their size and anatomical distribution. The patterns in quantity, size and distribution of tumors revealed interesting aspects in the clinical manifestation of FP in specimens studied in Brazil, and that FP scoring systems developed for other areas might not perform adequately when applied to sea turtles on the Southwest Atlantic Ocean. We therefore propose a novel method to evaluate the clinical manifestation of FP: fibropapillomatosis index (FPI) that provides the Southwest Atlantic fibropapillomatosis score (FPSSWA). In combination, these indexing and scoring systems allow for a more objective, rapid and detailed evaluation of the severity of FP in green sea turtles. While primarily designed for the clinical manifestation of FP currently witnessed in our dataset, this index and the score system can be adapted for other areas and compare the characteristics of the disease across regions. In conclusion, scoring systems to classify the severity of FP can assist our understanding on the environmental factors that modulate its development and its impacts on the individual and population health of green sea turtles. PMID:27936118
Rossi, Silmara; Sánchez-Sarmiento, Angélica María; Vanstreels, Ralph Eric Thijl; Dos Santos, Robson Guimarães; Prioste, Fabiola Eloisa Setim; Gattamorta, Marco Aurélio; Grisi-Filho, José Henrique Hildebrand; Matushima, Eliana Reiko
2016-01-01
Fibropapillomatosis (FP) is a neoplastic disease that affects marine turtles worldwide, especially green sea turtles (Chelonia mydas). FP tumors can develop on the body surface of marine turtles and also internally in the oral cavity and viscera. Depending on their quantity, size and anatomical distribution, these tumors can interfere with hydrodynamics and the ability to feed, hence scoring systems have been proposed in an attempt to quantify the clinical manifestation of FP. In order to establish a new scoring system adapted to geographic regions, we examined 214 juvenile green sea turtles with FP caught or rescued at Brazilian feeding areas, counted their 7466 tumors and classified them in relation to their size and anatomical distribution. The patterns in quantity, size and distribution of tumors revealed interesting aspects in the clinical manifestation of FP in specimens studied in Brazil, and that FP scoring systems developed for other areas might not perform adequately when applied to sea turtles on the Southwest Atlantic Ocean. We therefore propose a novel method to evaluate the clinical manifestation of FP: fibropapillomatosis index (FPI) that provides the Southwest Atlantic fibropapillomatosis score (FPSSWA). In combination, these indexing and scoring systems allow for a more objective, rapid and detailed evaluation of the severity of FP in green sea turtles. While primarily designed for the clinical manifestation of FP currently witnessed in our dataset, this index and the score system can be adapted for other areas and compare the characteristics of the disease across regions. In conclusion, scoring systems to classify the severity of FP can assist our understanding on the environmental factors that modulate its development and its impacts on the individual and population health of green sea turtles.
Thompson, Patrick C; Dalman, Ronald L; Harris, E John; Chandra, Venita; Lee, Jason T; Mell, Matthew W
2016-12-01
The clinical decision-making utility of scoring algorithms for predicting mortality after ruptured abdominal aortic aneurysms (rAAAs) remains unknown. We sought to determine the clinical utility of the algorithms compared with our clinical decision making and outcomes for management of rAAA during a 10-year period. Patients admitted with a diagnosis rAAA at a large university hospital were identified from 2005 to 2014. The Glasgow Aneurysm Score, Hardman Index, Vancouver Score, Edinburgh Ruptured Aneurysm Score, University of Washington Ruptured Aneurysm Score, Vascular Study Group of New England rAAA Risk Score, and the Artificial Neural Network Score were analyzed for accuracy in predicting mortality. Among patients quantified into the highest-risk group (predicted mortality >80%-85%), we compared the predicted with the actual outcome to determine how well these scores predicted futility. The cohort comprised 64 patients. Of those, 24 (38%) underwent open repair, 36 (56%) underwent endovascular repair, and 4 (6%) received only comfort care. Overall mortality was 30% (open repair, 26%; endovascular repair, 24%; no repair, 100%). As assessed by the scoring systems, 5% to 35% of patients were categorized as high-mortality risk. Intersystem agreement was poor, with κ values ranging from 0.06 to 0.79. Actual mortality was lower than the predicted mortality (50%-70% vs 78%-100%) for all scoring systems, with each scoring system overestimating mortality by 10% to 50%. Mortality rates for patients not designated into the high-risk cohort were dramatically lower, ranging from 7% to 29%. Futility, defined as 100% mortality, was predicted in five of 63 patients with the Hardman Index and in two of 63 of the University of Washington score. Of these, surgery was not offered to one of five and one of two patients, respectively. If one of these two models were used to withhold operative intervention, the mortality of these patients would have been 100%. The actual mortality for these patients was 60% and 50%, respectively. Clinical algorithms for predicting mortality after rAAA were not useful for predicting futility. Most patients with rAAA were not classified in the highest-risk group by the clinical decision models. Among patients identified as highest risk, predicted mortality was overestimated compared with actual mortality. The data from this study support the limited value to surgeons of the currently published algorithms. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Zhong, Min; Chen, Wan Jun; Lu, Xiao Ye; Qian, Jie; Zhu, Chang Qing
2016-12-01
To compare the performances of the Glasgow-Blatchford score (GBS), modified GBS (mGBS) and AIMS65 in predicting clinical outcomes in patients with acute upper gastrointestinal bleeding (AUGIB). This study enrolled 320 consecutive patients with AUGIB. Patients at high and low risks of developing adverse clinical outcomes (rebleeding, the need of clinical intervention and death) were categorized according to the GBS, mGBS and AIMS65 scoring systems. The outcome of the patients were the occurrences of adverse clinical outcomes. The areas under the receiver operating characteristics curve (AUROC) of three scoring systems were compared. Irrespective of the systems used, the high-risk groups showed higher rates of rebleeding, intervention and death compared with the low-risk groups (P < 0.05). For the prediction of rebleeding, AIMS65 (AUROC 0.735, 95% CI 0.667-0.802) performed significantly better than GBS (AUROC 0.672, 95% CI 0.597-0.747; P < 0.01) and mGBS (AUROC 0.677, 95% CI 0.602-0.753; P < 0.01). For the prediction of interventions, there was no significant difference among the three systems (GBS: AUROC 0.769, 95% CI 0.668-0.870; mGBS: AUROC 0.745, 95% CI 0.643-0.847; AIMS65: AUROC 0.746, 95% CI 0.640-0.851). For the prediction of in-hospital mortality, there was no significant difference among the three systems (GBS: AUROC 0.796, 95% CI 0.694-0.898; mGBS: AUROC 0.803, 95% CI 0.703-0.904; AIMS65: AUROC 0.786, 95% CI 0.670-0.903). The three scoring systems are reliable and accurate in predicting the rates of rebleeding, surgery and mortality in AUGIB. However, AIMS65 outperforms GBS and mGBS in predicting rebleeding. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Lim, Chen Kim; Tan, Kian Lam; Yusran, Hazwanni; Suppramaniam, Vicknesh
2017-10-01
Visual language or visual representation has been used in the past few years in order to express the knowledge in graphic. One of the important graphical elements is fractal and L-Systems is a mathematic-based grammatical model for modelling cell development and plant topology. From the plant model, L-Systems can be interpreted as music sound and score. In this paper, LSound which is a Visual Language Programming (VLP) framework has been developed to model plant to music sound and generate music score and vice versa. The objectives of this research has three folds: (i) To expand the grammar dictionary of L-Systems music based on visual programming, (ii) To design and produce a user-friendly and icon based visual language framework typically for L-Systems musical score generation which helps the basic learners in musical field and (iii) To generate music score from plant models and vice versa using L-Systems method. This research undergoes a four phases methodology where the plant is first modelled, then the music is interpreted, followed by the output of music sound through MIDI and finally score is generated. LSound is technically compared to other existing applications in the aspects of the capability of modelling the plant, rendering the music and generating the sound. It has been found that LSound is a flexible framework in which the plant can be easily altered through arrow-based programming and the music score can be altered through the music symbols and notes. This work encourages non-experts to understand L-Systems and music hand-in-hand.
Aoki, Tomonori; Nagata, Naoyoshi; Shimbo, Takuro; Niikura, Ryota; Sakurai, Toshiyuki; Moriyasu, Shiori; Okubo, Hidetaka; Sekine, Katsunori; Watanabe, Kazuhiro; Yokoi, Chizu; Yanase, Mikio; Akiyama, Junichi; Mizokami, Masashi; Uemura, Naomi
2016-11-01
We aimed to develop and validate a risk scoring system to determine the risk of severe lower gastrointestinal bleeding (LGIB) and predict patient outcomes. We first performed a retrospective analysis of data from 439 patients emergently hospitalized for acute LGIB at the National Center for Global Health and Medicine in Japan, from January 2009 through December 2013. We used data on comorbidities, medication, presenting symptoms, and vital signs, and laboratory test results to develop a scoring system for severe LGIB (defined as continuous and/or recurrent bleeding). We validated the risk score in a prospective study of 161 patients with acute LGIB admitted to the same center from April 2014 through April 2015. We assessed the system's accuracy in predicting patient outcome using area under the receiver operating characteristics curve (AUC) analysis. All patients underwent colonoscopy. In the first study, 29% of the patients developed severe LGIB. We devised a risk scoring system based on nonsteroidal anti-inflammatory drugs use, no diarrhea, no abdominal tenderness, blood pressure of 100 mm Hg or lower, antiplatelet drugs use, albumin level less than 3.0 g/dL, disease scores of 2 or higher, and syncope (NOBLADS), which all were independent correlates of severe LGIB. Severe LGIB developed in 75.7% of patients with scores of 5 or higher compared with 2% of patients without any of the factors correlated with severe LGIB (P < .001). The NOBLADS score determined the severity of LGIB with an AUC value of 0.77. In the validation (second) study, severe LGIB developed in 35% of patients; the NOBLADS score predicted the severity of LGIB with an AUC value of 0.76. Higher NOBLADS scores were associated with a requirement for blood transfusion, longer hospital stay, and intervention (P < .05 for trend). We developed and validated a scoring system for risk of severe LGIB based on 8 factors (NOBLADS score). The system also determined the risk for blood transfusion, longer hospital stay, and intervention. It might be used in decision making regarding intervention and management. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.
Thombs, Brett D; Kwakkenbos, Linda; Riehm, Kira E; Saadat, Nazanin; Fedoruk, Claire
2017-02-01
The complexity and burden of systemic sclerosis (SSc) pose challenges to developing and sustaining disease management self-efficacy. The objective of this systematic review was to compare scores on a commonly used self-efficacy measure, the Self-Efficacy for Managing Chronic Disease (SEMCD) Scale, between SSc and other diseases. Data sources included the CINAHL, EMBASE, MEDLINE, and Scopus databases, searched through January 25, 2016, and reference lists of included articles and relevant reviews. Studies in any language that reported total SEMCD scores or individual item scores in adult non-psychiatric medical patients were eligible. We identified one eligible non-intervention study of SSc patients (n = 553), 13 other non-intervention studies, and 21 studies with pre-intervention data for patients enrolled in a self-management program or a trial of a program. Of 13 non-intervention studies with published total score means in cancer, cardiovascular disease, Parkinson's disease, spinal cord injuries, organ transplant candidates and recipients, dialysis, and lupus, SEMCD scores were statistically significantly lower (poorer self-efficacy) in SSc than 6 other disease samples, not significantly different from 6, and significantly higher than lupus patients. Compared to 18 studies of patients in self-management programs or trials with published total score means, SSc patients were similar or lower than 9 samples and significantly higher than 9 samples. Compared to patients with other diseases not enrolled in programs to improve self-efficacy, SSc patients report lower self-efficacy scores than most patient groups. Rigorously tested self-care interventions designed to meet the unique needs of patients with SSc are needed.
Srinivasan, M; Shetty, N; Gadekari, S; Thunga, G; Rao, K; Kunhikatta, V
2017-07-01
Severity or mortality prediction of nosocomial pneumonia could aid in the effective triage of patients and assisting physicians. To compare various severity assessment scoring systems for predicting intensive care unit (ICU) mortality in nosocomial pneumonia patients. A prospective cohort study was conducted in a tertiary care university-affiliated hospital in Manipal, India. One hundred patients with nosocomial pneumonia, admitted in the ICUs who developed pneumonia after >48h of admission, were included. The Nosocomial Pneumonia Mortality Prediction (NPMP) model, developed in our hospital, was compared with Acute Physiology and Chronic Health Evaluation II (APACHE II), Mortality Probability Model II (MPM 72 II), Simplified Acute Physiology Score II (SAPS II), Multiple Organ Dysfunction Score (MODS), Sequential Organ Failure Assessment (SOFA), Clinical Pulmonary Infection Score (CPIS), Ventilator-Associated Pneumonia Predisposition, Insult, Response, Organ dysfunction (VAP-PIRO). Data and clinical variables were collected on the day of pneumonia diagnosis. The outcome for the study was ICU mortality. The sensitivity and specificity of the various scoring systems was analysed by plotting receiver operating characteristic (ROC) curves and computing the area under the curve for each of the mortality predicting tools. NPMP, APACHE II, SAPS II, MPM 72 II, SOFA, and VAP-PIRO were found to have similar and acceptable discrimination power as assessed by the area under the ROC curve. The AUC values for the above scores ranged from 0.735 to 0.762. CPIS and MODS showed least discrimination. NPMP is a specific tool to predict mortality in nosocomial pneumonia and is comparable to other standard scores. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Venkatadass, K; Grandhi, Tarani Sai Prasanth; Rajasekaran, S
2017-11-01
Open injuries in children are rare compared to adults. In children with major open injuries, there is no specific scoring system to guide when to amputate or salvage the limb. The use of available adult scoring systems may lead to errors in management. The role of Ganga Hospital Open Injury Severity Scoring (GHOISS) for open injuries in adults is well established and its applicability for pediatric open injuries has not been studied. This study was done to analyse the usefulness of GHOISS in pediatric open injuries and to compare it with MESS(Mangled Extremity Severity Score). All children (0-18 years) who were admitted with Open type IIIB injuries of lower limbs between January 2008 and March 2015 were included. MESS and GHOISS were calculated for all the patients. There were 50 children with 52 type IIIB Open injuries of which 39 had open tibial fractures and 13 had open femur fractures. Out of 52 type IIIB open injuries, 48 were salvaged and 4 were amputated. A MESS score of 7 and above had sensitivity of 25% for amputation while GHOISS of 17 and above was found to be more accurate for determining amputation with sensitivity of 75% and specificity of 93.75%. GHOISS is a reliable predictor of injury severity in type IIIB open fractures in children and can be used as a guide for decision-making. The use of MESS score in children has a lower predictive value compared to GHOISS in deciding amputation versus salvage. A GHOISS of 17 or more has the highest sensitivity and specificity to predict amputation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Autonomic Nervous System Reactivity: Children With and Without Sickle Cell Disease
Treadwell, Marsha J.; Alkon, Abbey; Styles, Lori; Boyce, W. Thomas
2011-01-01
Background Previous studies of healthy children have demonstrated a link between autonomic nervous system (ANS) reactivity and health outcomes, but there is limited research on whether ANS reactivity is similar for children with chronic conditions. Objective To determine if ANS reactivity differs for children with sickle cell disease (SCD) compared to a community sample of children without SCD. Method In two cross-sectional, descriptive studies, 32 public school children without chronic health problems were compared with 33 children with SCD. The children were 5-8 years old and they completed standardized protocols measuring ANS responses (respiratory sinus arrhythmia and pre-ejection period) during rest and challenge conditions in social, cognitive, sensory, and emotion domains. Reactivity was calculated as the difference between challenge response minus rest for each domain and overall. Results There were differences in the distributions of the samples in parent education and child age, so these variables were adjusted for in subsequent analyses. The community sample showed parasympathetic withdrawal (low respiratory sinus arrhythmia scores) and greater parasympathetic reactivity (low respiratory sinus arrhythmia difference scores and percentage of negative scores) compared with the children with SCD in the social (p < .05) and sensory domains (p < .05). The children with SCD showed greater sympathetic reactivity (low preejection period difference scores) compared with the community children in the cognitive domain (p < .05) and a greater percentage of children with SCD versus the community children showed negative pre-ejection period difference scores (sympathetic reactivity) in the social domain (p < .05). The community sample, but not the children with SCD, showed changes in respiratory sinus arrhythmia across domains (p < .05). Discussion Children with SCD may display a different pattern of ANS responses to laboratory challenges compared with children without SCD from the same community. PMID:21532352
Vicentini, Fabio C.; Serzedello, Felipe R.; Thomas, Kay; Marchini, Giovanni S.; Torricelli, Fabio C. M.; Srougi, Miguel; Mazzucchi, Eduardo
2017-01-01
ABSTRACT Objective: To compare the application time and the capacity of the nomograms to predict the success of Guy's Stone Score (GSS), S.T.O.N.E. Nephrolithometry (STONE) and Clinical Research Office of the Endourological Society nephrolithometric nomogram (CROES) of percutaneous nephrolithotomy (PCNL), evaluating the most efficient one for clinical use. Materials and Methods: We studied 48 patients who underwent PCNL by the same surgeon between 2010 and 2011. We calculated GSS, STONE and CROES based on pre-operative non-contrast computed tomography (CT) images and clinical data. A single observer, blinded to the outcomes, reviewed all images and assigned scores. We compared the application time of each nomogram. We used an analysis of variance for repeated measures and multiple comparisons by the Tukey test. We compared the area under the ROC curve (AUC) of the three nomograms two by two to determine the most predictive scoring system. Results: The immediate success rate was 66.7% and complications occurred in 16.7% of cases. The average operative time was 122 minutes. Mean application time was significantly lower for the GSS (27.5 seconds) when compared to 300.6 seconds for STONE and 213.4 seconds for CROES (p<0.001). There was no significant difference among the GSS (AUC=0.653), STONE (AUC=0.563) and CROES (AUC=0.641) in the ability to predict immediate success of PCNL. Conclusions: All three nomograms showed similar ability to predict success of PCNL, however the GSS was the quickest to be applied, what is an important issue for routine clinical use when counseling patients who are candidates to PCNL. PMID:28338303
Semi-automatic computerized approach to radiological quantification in rheumatoid arthritis
NASA Astrophysics Data System (ADS)
Steiner, Wolfgang; Schoeffmann, Sylvia; Prommegger, Andrea; Boegl, Karl; Klinger, Thomas; Peloschek, Philipp; Kainberger, Franz
2004-04-01
Rheumatoid Arthritis (RA) is a common systemic disease predominantly involving the joints. Precise diagnosis and follow-up therapy requires objective quantification. For this purpose, radiological analyses using standardized scoring systems are considered to be the most appropriate method. The aim of our study is to develop a semi-automatic image analysis software, especially applicable for scoring of joints in rheumatic disorders. The X-Ray RheumaCoach software delivers various scoring systems (Larsen-Score and Ratingen-Rau-Score) which can be applied by the scorer. In addition to the qualitative assessment of joints performed by the radiologist, a semi-automatic image analysis for joint detection and measurements of bone diameters and swollen tissue supports the image assessment process. More than 3000 radiographs from hands and feet of more than 200 RA patients were collected, analyzed, and statistically evaluated. Radiographs were quantified using conventional paper-based Larsen score and the X-Ray RheumaCoach software. The use of the software shortened the scoring time by about 25 percent and reduced the rate of erroneous scorings in all our studies. Compared to paper-based scoring methods, the X-Ray RheumaCoach software offers several advantages: (i) Structured data analysis and input that minimizes variance by standardization, (ii) faster and more precise calculation of sum scores and indices, (iii) permanent data storing and fast access to the software"s database, (iv) the possibility of cross-calculation to other scores, (v) semi-automatic assessment of images, and (vii) reliable documentation of results in the form of graphical printouts.
The Importance of Rockall Scoring System for Upper Gastrointestinal Bleeding in Long-Term Follow-Up.
Bozkurt, Mehmet Abdussamet; Peker, Kıvanç Derya; Unsal, Mustafa Gökhan; Yırgın, Hakan; Kahraman, İzzettin; Alış, Halil
2017-06-01
The aim of the study is to examine the importance of Rockall scoring system in long-term setting to estimate re-bleeding and mortality rate due to upper gastrointestinal bleeding. A total of 321 patients who had been treated for upper gastrointestinal bleeding were recruited to the study. Patients' demographic and clinical data, the amount of blood transfusion, endoscopy results, and Rockall scores were retrieved from patients' charts. The re-bleeding, morbidity, and mortality rates were noted after 3 years of follow-up with telephone. Re-bleeding rate was statistically significantly higher in Rockall 4 group compared to Rockall 0 group. Mortality rate was also statistically significantly higher in Rockall 4 group. Rockall risk scoring system is a valuable tool to predict re-bleeding and mortality rates for patients with upper gastrointestinal bleeding in long-term setting.
Autofocus system and autofocus method for focusing on a surface
O'Neill, Mary Morabito
2017-05-23
An autofocus system includes an imaging device, a lens system and a focus control actuator that is configured to change a focus position of the imaging device in relation to a stage. The electronic control unit is configured to control the focus control actuator to a plurality of predetermined focus positions, and activate the imaging device to obtain an image at predetermined positions and then apply a spatial filter to the obtained images. This generates a filtered image for the obtained images. The control unit determines a focus score for the filtered images such that the focus score corresponds to a degree of focus in the obtained images. The control unit identifies a best focus position by comparing the focus score of the filtered images, and controls the focus control actuator to the best focus position corresponding to the highest focus score.
Lohsiriwat, Varut; Prapasrivorakul, Siriluck; Lohsiriwat, Darin
2009-01-01
The purposes of this study were to determine clinical presentations and surgical outcomes of perforated peptic ulcer (PPU), and to evaluate the accuracy of the Boey scoring system in predicting mortality and morbidity. We carried out a retrospective study of patients undergoing emergency surgery for PPU between 2001 and 2006 in a university hospital. Clinical presentations and surgical outcomes were analyzed. Adjusted odds ratio (OR) of each Boey score on morbidity and mortality rate was compared with zero risk score. Receiver-operating characteristic curve analysis was used to compare the predictive ability between Boey score, American Society of Anesthesiologists (ASA) classification, and Mannheim Peritonitis Index (MPI). The study included 152 patients with average age of 52 years (range: 15-88 years), and 78% were male. The most common site of PPU was the prepyloric region (74%). Primary closure and omental graft was the most common procedure performed. Overall mortality rate was 9% and the complication rate was 30%. The mortality rate increased progressively with increasing numbers of the Boey score: 1%, 8% (OR=2.4), 33% (OR=3.5), and 38% (OR=7.7) for 0, 1, 2, and 3 scores, respectively (p<0.001). The morbidity rates for 0, 1, 2, and 3 Boey scores were 11%, 47% (OR=2.9), 75% (OR=4.3), and 77% (OR=4.9), respectively (p<0.001). Boey score and ASA classification appeared to be better than MPI for predicting the poor surgical outcomes. Perforated peptic ulcer is associated with high rates of mortality and morbidity. The Boey risk score serves as a simple and precise predictor for postoperative mortality and morbidity.
Novel and Practical Scoring Systems for the Diagnosis of Thyroid Nodules
Wei, Ying; Zhou, Xinrong; Liu, Siyue; Wang, Hong; Liu, Limin; Liu, Renze; Kang, Jinsong; Hong, Kai; Wang, Daowen; Yuan, Gang
2016-01-01
Objective The clinical management of patients with thyroid nodules that are biopsied by fine-needle aspiration cytology and yield indeterminate results remains unsettled. The BRAF V600E mutation has dubious diagnostic value due to its low sensitivity. Novel strategies are urgently needed to distinguish thyroid malignancies from thyroid nodules. Design This prospective study included 504 thyroid nodules diagnosed by ultrasonography from 468 patients, and fine-needle aspiration cytology was performed under ultrasound guidance. Cytology and molecular analysis, including BRAF V600E, RET/PTC1 and RET/PTC3, were conducted simultaneously. The cytology, ultrasonography results, and mutational status were gathered and analyzed together. Predictive scoring systems were designed using a combination of diagnostic parameters for ultrasonography, cytology and genetic analysis. The utility of the scoring systems was analyzed and compared to detection using the individual methods alone or combined. Result The sensitivity of scoring systema (ultrasonography, cytology, BRAF V600E, RET/PTC) was nearly identical to that of scoring systemb (ultrasonography, cytology, BRAF V600E); these were 91.0% and 90.2%, respectively. These sensitivities were significantly higher than those obtained using FNAC, genetic analysis and US alone or combined; their sensitivities were 63.9%, 70.7% and 87.2%, respectively. Scoring systemc (ultrasonography, cytology) was slightly inferior to the former two scoring systems but still had relatively high sensitivity and specificity (80.5% and 95.1%, respectively), which were significantly superior to those of single cytology, ultrasonography or genetic analysis. In nodules with uncertainty cytology, scoring systema, scoring systemb and scoring systemc could elevate the malignancy detection rates to 69.7%, 69.7% and 63.6%, respectively. Conclusion These three scoring systems were quick for clinicians to master and could provide quantified information to predict the probability of malignant nodules. Scoring systemb is recommended for improving the detection rate among nodules of uncertain cytology. PMID:27654865
Panzer, Stephanie; Pernter, Patrizia; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zesch, Stephanie; Rosendahl, Wilfried; Hotz, Gerhard; Zink, Albert R
2017-12-01
Purpose Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the "Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies" to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. Materials and Methods A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6 mm; kilovolt ranging from 80 to 140). For standardized evaluation the "CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies" was used. Results All checkpoints under category "A. Soft Tissues of Head and Musculoskeletal System" and more than half in category "B. Organs and Organ Systems" were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Conclusion Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation. Key Points · The approach of structured reporting can be transferred to paleoradiology.. · The checklist allowed for standardized soft tissue assessment and documentation.. · The scoring system facilitated a quantitative comparison among mummies.. · Based on CT, the Tyrolean Iceman demonstrated remarkable soft tissue preservation.. Citation Format · Panzer S, Pernter P, Piombino-Mascali D et al. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman. Fortschr Röntgenstr 2017; 189: 1152 - 1160. © Georg Thieme Verlag KG Stuttgart · New York.
Khan, Fehmeda Farrukh; Numan, Ahsan; Khawaja, Khadija Irfan; Atif, Ali; Fatima, Aziz; Masud, Faisal
2015-01-01
Early diagnosis of distal peripheral neuropathy (DSPN) the commonest diabetes complications, helps prevent significant morbidity. Clinical parameters are useful for detection, but subjectivity and lack of operator proficiency often results in inaccuracies. Comparative diagnostic accuracy of Diabetic Neuropathy Symptom (DNS) score and Diabetic Neuropathy Examination (DNE) score in detecting DSPN confirmed by nerve conduction studies (NCS) has not been evaluated. This study compares the performance of these scores in predicting the presence of electro physiologically proven DSPN. The objective of this, study was to compare the diagnostic accuracy of DNS and DNE scores in detecting NCS proven DSPN in type-2 diabetics, and to determine the frequency of sub-clinical DSPN among type-2 diabetics. In this cross-sectional study the DNS score and DNE score were determined in 110 diagnosed type-2 diabetic patients. NCS were carried out and amplitudes, velocities and latencies of sensory and motor nerves in lower limb were recorded. Comparison between the two clinical diagnostic modalities and NCS using Pearson's chi square test showed a significant association between NCS and DNE scores (p-value =.003, specificity 93%). The DNS score performed poorly in comparison (p-value = .068, specificity 77%). When the two scores were taken in combination the specificity in diagnosing DSPN was greater (p-value = .018, specificity 96%) than either alone. 33% of patients had subclinical neuropathy. DNE score alone and in combination with DNS score is reliable in predicting DSPN and is more specific than DNS score in evaluating DSPN. Both tests lack sensitivity. Patients without any evidence of clinical neuropathy manifest abnormalities on NCS.
Harimoto, Norifumi; Yoshizumi, Tomoharu; Sakata, Kazuhito; Nagatsu, Akihisa; Motomura, Takashi; Itoh, Shinji; Harada, Noboru; Ikegami, Toru; Uchiyama, Hideaki; Soejima, Yuji; Maehara, Yoshihiko
2017-11-01
In recent years, the establishment of new staging systems for hepatocellular carcinoma (HCC) has been reported worldwide. The system combining albumin-bilirubin (ALBI) with tumor-node-metastasis stage, developed by the Liver Cancer Study Group of Japan, was called the ALBI-T score. Patient data were retrospectively collected for 357 consecutive patients who had undergone hepatic resection for HCC with curative intent between January 2004 and December 2015. The overall survival and recurrence-free survival were compared by the Kaplan-Meier method, using different staging systems: the Japan integrated staging (JIS), modified JIS, and ALBI-T. Multivariate analysis identified five poor prognostic factors (higher age, poor differentiation, the presence of microvascular invasion, the presence of intrahepatic metastasis, and blood transfusion) that influenced overall survival, and four poor prognostic factors (the presence of intrahepatic metastasis, serum α-fetoprotein level, blood transfusion, and each staging system (JIS, modified JIS, and ALBI-T score)) that influenced recurrence-free survival. Patients for each these three staging system had a significantly worse prognosis regarding recurrence-free survival, but not with overall survival. The modified JIS score showed the lowest Akaike information criteria statistic value, indicating it had the best ability to predict overall survival compared with the other staging systems. This retrospective analysis showed that, in post-hepatectomy patients with HCC, the ALBI-T score is predictive of worse recurrence-free survival, even when adjustments are made for other known predictors. However, modified JIS is better than ALBI-T in predicting overall survival. © 2017 The Japan Society of Hepatology.
The corneal transplant score: a simple corneal graft candidate calculator.
Rosenfeld, Eldar; Varssano, David
2013-07-01
Shortage of corneas for transplantation has created long waiting lists in most countries. Transplant calculators are available for many organs. The purpose of this study is to describe a simple automatic scoring system for keratoplasty recipient candidates, based on several parameters that we consider most relevant for tissue allocation, and to compare the system's accuracy in predicting decisions made by a cornea specialist. Twenty pairs of candidate data were randomly created on an electronic spreadsheet. A single priority score was computed from the data of each candidate. A cornea surgeon and the automated system then decided independently which candidate in each pair should have surgery if only a single cornea was available. The scoring system can calculate values between 0 (lowest priority) and 18 (highest priority) for each candidate. Average score value in our randomly created cohort was 6.35 ± 2.38 (mean ± SD), range 1.28 to 10.76. Average score difference between the candidates in each pair was 3.12 ± 2.10, range 0.08 to 8.45. The manual scoring process, although theoretical, was mentally and emotionally demanding for the surgeon. Agreement was achieved between the human decision and the calculated value in 19 of 20 pairs. Disagreement was reached in the pair with the lowest score difference (0.08). With worldwide donor cornea shortage, waiting for transplantation can be long. Manual sorting of priority for transplantation in a long waiting list is difficult, time-consuming and prone to error. The suggested system may help achieve a justified distribution of available tissue.
Bourgioti, Charis; Chatoupis, Konstantinos; Panourgias, Evangelia; Tzavara, Chara; Sarris, Kyrillos; Rodolakis, Alexandros; Moulopoulos, Lia Angela
2015-10-01
To report discriminant MRI features between cervical and endometrial carcinomas and to design an MRI- scoring system, with the potential to predict the origin of uterine cancer (cervix or endometrium) in histologically indeterminate cases. Dedicated pelvic MRIs of 77 patients with uterine tumors involving both cervix and corpus were retrospectively analyzed by two experts in female imaging. Seven MRI tumor characteristics were statistically tested for their discriminant ability for tumor origin compared to final histology: tumor location, perfusion pattern, rim enhancement, depth of myometrial invasion, cervical stromal integrity, intracavitary mass, and retained endometrial secretions. Kappa values were estimated to assess the levels of inter-rater reliability. On the basis of positive likelihood ratio values, an MRI-score was assigned. K value was excellent for most of the imaging criteria. Using ROC curve analysis, the estimated optimal cut-off for the MRI-scoring system was 4 with 96.6% sensitivity and 100% specificity. Using a ≥4 cut-off for cervical cancers and <4 for endometrial cancers, 97.4% of the patients were correctly classified. 2/58 patients with cervical cancer had MRI score <4 and none of the patients with endometrial cancer had MRI score >4. The area under curve of the MRI-scoring system was 0.99 (95% CI 0.98-1.00). When the MRI-score was applied to 20/77 patients with indeterminate initial biopsy and to 5/26 surgically treated patients with erroneous pre-op histology, all cases were correctly classified. The produced MRI-scoring system may be a reliable problem-solving tool for the differential diagnosis of cervical vs. endometrial cancer in cases of equivocal histology.
Sepsis mortality prediction with the Quotient Basis Kernel.
Ribas Ripoll, Vicent J; Vellido, Alfredo; Romero, Enrique; Ruiz-Rodríguez, Juan Carlos
2014-05-01
This paper presents an algorithm to assess the risk of death in patients with sepsis. Sepsis is a common clinical syndrome in the intensive care unit (ICU) that can lead to severe sepsis, a severe state of septic shock or multi-organ failure. The proposed algorithm may be implemented as part of a clinical decision support system that can be used in combination with the scores deployed in the ICU to improve the accuracy, sensitivity and specificity of mortality prediction for patients with sepsis. In this paper, we used the Simplified Acute Physiology Score (SAPS) for ICU patients and the Sequential Organ Failure Assessment (SOFA) to build our kernels and algorithms. In the proposed method, we embed the available data in a suitable feature space and use algorithms based on linear algebra, geometry and statistics for inference. We present a simplified version of the Fisher kernel (practical Fisher kernel for multinomial distributions), as well as a novel kernel that we named the Quotient Basis Kernel (QBK). These kernels are used as the basis for mortality prediction using soft-margin support vector machines. The two new kernels presented are compared against other generative kernels based on the Jensen-Shannon metric (centred, exponential and inverse) and other widely used kernels (linear, polynomial and Gaussian). Clinical relevance is also evaluated by comparing these results with logistic regression and the standard clinical prediction method based on the initial SAPS score. As described in this paper, we tested the new methods via cross-validation with a cohort of 400 test patients. The results obtained using our methods compare favourably with those obtained using alternative kernels (80.18% accuracy for the QBK) and the standard clinical prediction method, which are based on the basal SAPS score or logistic regression (71.32% and 71.55%, respectively). The QBK presented a sensitivity and specificity of 79.34% and 83.24%, which outperformed the other kernels analysed, logistic regression and the standard clinical prediction method based on the basal SAPS score. Several scoring systems for patients with sepsis have been introduced and developed over the last 30 years. They allow for the assessment of the severity of disease and provide an estimate of in-hospital mortality. Physiology-based scoring systems are applied to critically ill patients and have a number of advantages over diagnosis-based systems. Severity score systems are often used to stratify critically ill patients for possible inclusion in clinical trials. In this paper, we present an effective algorithm that combines both scoring methodologies for the assessment of death in patients with sepsis that can be used to improve the sensitivity and specificity of the currently available methods. Copyright © 2014 Elsevier B.V. All rights reserved.
Comparative study of design and PCL-substituting systems of total knee prosthesis.
Adam, R; Orban, C; Orban, H
2014-01-01
The aim of this study is to assess postoperative results obtained by different knee implants. The main implant types differences are given by generally implant design and by PCL substituting systems that are used. Between 04.2004 - 02.2012 we have performed 506 total knee arthroplasties (TKA), on a group of 460 patients. Our choice, was for cemented total knee prostheses, using PCL-substituting systems. Regarding general design and PCL-substituting systems of the implant we had divided the main group in three lots. In order to assess post operative result we had used the American Knee Society Score(AKSS). All prostheses types that we had implanted, had registered satisfactory values of AKSS. Our study showed that one group scored higher values of AKSS, compared the other two, but there are not statistical semnificative differences (p=0,09). Celsius.
[Comparison of different types automatic water-supply system for mouse rearing (author's transl)].
Kikuchi, S; Suzuki, M; Tagashira, Y
1979-04-01
Rearing and breeding scores were compared between groups of mice (JCL : ICR and ddN strains) raised with two different types of automatic water-supply systems; the Japanese type and the American type, using manual water-supply system as control. The mice raised with the manual water-supply system were superior in body weight gain as compared to those with two automatic water-supply systems. As to the survival rate, however, the m; anual water-supply system and the Japanese type gave better results than the American type. As to weanling rate in the breeding test, the manual water-supply system gave somewhat better result than either of the two automatic types. Accidental water leaks, which are serious problems of automatic systems, occurred frequently only when the American type was used. Only one defect of the Japanese type revealed was that it was unfavorable for mice with smaller size (e.g., young ddN mice), resulting in lower body weight gain as well as lower breeding scores.
ERIC Educational Resources Information Center
Christensen, William Howard
2013-01-01
In 2010, the federal government increased accountability expectations by placing more emphasis on monitoring teacher performance. Using a model that focuses on the New York State teacher evaluation system, that is comprised of a rubric for observation, local student assessment scores, and student state assessment scores, this…
Monitoring the Performance of Human and Automated Scores for Spoken Responses
ERIC Educational Resources Information Center
Wang, Zhen; Zechner, Klaus; Sun, Yu
2018-01-01
As automated scoring systems for spoken responses are increasingly used in language assessments, testing organizations need to analyze their performance, as compared to human raters, across several dimensions, for example, on individual items or based on subgroups of test takers. In addition, there is a need in testing organizations to establish…
Dexterity and Bench Assembly Work Productivity in Adults with Mild Mental Retardation.
ERIC Educational Resources Information Center
Serr, Russell; And Others
1994-01-01
This study compared dexterity scores using the Vocational Transit Test System and bench assembly work productivity in 30 adults with mild mental retardation. Moderately high correlations were found between work output and motor coordination, manual dexterity, finger dexterity (with and without assembly), and total dexterity score. Finger dexterity…
Computer-Automated Approach for Scoring Short Essays in an Introductory Statistics Course
ERIC Educational Resources Information Center
Zimmerman, Whitney Alicia; Kang, Hyun Bin; Kim, Kyung; Gao, Mengzhao; Johnson, Glenn; Clariana, Roy; Zhang, Fan
2018-01-01
Over two semesters short essay prompts were developed for use with the Graphical Interface for Knowledge Structure (GIKS), an automated essay scoring system. Participants were students in an undergraduate-level online introductory statistics course. The GIKS compares students' writing samples with an expert's to produce keyword occurrence and…
Huang, Jinwen; Xu, Dongrong; Peterson, Bradley S; Hu, Jianbo; Cao, Linfeng; Wei, Ning; Zhang, Yingran; Xu, Weijuan; Xu, Yi; Hu, Shaohua
2015-03-27
Several cross-cultural studies have suggested that emotions are influenced by the cultural background. Emotional reactions to International Affective Picture System (IAPS) images were compared between Chinese and American young adults. 120 Chinese undergraduates (53 females, 67 males; aged 18-25 years) were enrolled at Zhejiang University, China, and the valence and arousal components of their emotional responses to IAPS images were rated using the Self-Assessment Manikin (SAM) system. Then, valence and arousal scores were compared to those of 100 American undergraduates (50 females, 50 males) of the same age group, enrolled at Florida University and surveyed by Prof. PJ Lang in 2001. Valence scores assigned to 259/816 (31.74%) pictures differed significantly between Chinese and American female participants, while those assigned to 165/816 (20.22%) pictures differed significantly between Chinese and American males (P < 6 × 10(-5)). Of the 816 pictures, the arousal scores assigned to 101/816 (12.38%) pictures differed significantly between Chinese and American female participants; these scores significantly differed in 130/816 (15.93%) pictures between Chinese and American males (P < 6 × 10(-5)). Valence scores for pictures in the Erotic category differed significantly between Chinese and American females (P < 6 × 10(-5)). There were no significant differences in valence scores for the remaining eight categories studied between participants from the two countries, whether female or male. The IAPS norms require a modification for their appropriate application in Asian cultures.
Olivry, Thierry; Linder, Keith E; Paps, Judy S; Bizikova, Petra; Dunston, Stan; Donne, Nathalie; Mondoulet, Lucie
2012-12-01
Patch tests with allergens are used for the evaluation of cellular hypersensitivity to food and environmental allergens in dogs and humans with atopic dermatitis. Viaskin is a novel allergen epicutaneous delivery system that enhances epidermal allergen capture by immune cells. To compare the use of Viaskin and Finn chamber patch tests in dogs hypersensitive to mite allergens. Empty control or Dermatophagoides farinae house dust mite-containing Viaskin or Finn chamber patches were applied to the thoracic skin of six mite-hypersensitive Maltese-beagle crossbred atopic dogs. Lesions were graded 49 and 72 h after patch test application, and skin biopsies were collected after 72 h. Overall microscopic inflammation, eosinophil and T-lymphocyte infiltrations were scored. Positive macroscopic patch test reactions developed at five of six Viaskin application sites and four of six Finn chamber application sites. Median microscopic epidermal and dermal inflammation, as well as eosinophil and CD3 T-lymphocyte dermal scores were always higher in biopsies collected at Viaskin than at Finn chamber sites. Microscopic inflammation scores were significantly higher after mite allergen-containing Viaskin compared with empty patches, but this was not the case for mite-containing Finn chambers compared with control chambers. Scores obtained using Viaskin were not significantly different from those obtained using Finn chambers. Macroscopic and microscopic scores were significantly correlated. In mite-allergic dogs, Viaskin epicutaneous delivery systems appear to induce stronger allergen-specific inflammation than currently used Finn chamber patch tests. Consequently, Viaskin patches might offer a better alternative for screening cellular hypersensitivity to food and environmental allergens. © 2012 The Authors. Veterinary Dermatology © 2012 ESVD and ACVD.
Sokhal, Navdeep; Rath, Girija Prasad; Chaturvedi, Arvind; Singh, Manmohan; Dash, Hari Hara
2017-08-01
Mannitol and hypertonic saline (HS) are most commonly used hyperosmotic agents for intraoperative brain relaxation. We compared the changes in ICP and systemic hemodynamics after infusion of equiosmolar solutions of both agents in patients undergoing craniotomy for supratentorial tumors. Forty enrolled adults underwent a standard anesthetic induction. Apart from routine monitoring parameters, subdural ICP with Codmann catheter and cardiac indices by Vigileo monitor, were recorded. The patients were randomized to receive equiosmolar solutions of either 20% mannitol (5ml/kg) or 3% HS (5.35ml/kg) for brain relaxation. The time of placement of ICP catheter was marked as T 0 and baseline ICP and systemic hemodynamic variables were noted; it was followed by recording of the same parameters every 5min till 45min (Study Period). After the completion of study period, brain relaxation score as assessed by the neurosurgeon was recorded. Arterial blood gas (ABG) was analysed every 30min starting from T 0 upto one and half hours (T 90 ), and values of various parameters were recorded. Data was analysed using appropriate statistical methods. Both mannitol and HS significantly reduced the ICP; the values were comparable in between the two groups at most of the times. The brain relaxation score was comparable in both the groups. Urine output was significantly higher with mannitol. The perioperative complications, overall hospital stay, and Glasgow outcome score at discharge were comparable in between the two groups. To conclude, both mannitol and hypertonic saline in equiosmolar concentrations produced comparable effects on ICP reduction, brain relaxation, and systemic hemodynamics. Copyright © 2017 Elsevier Ltd. All rights reserved.
End-tidal CO2-guided automated robot CPR system in the pig. Preliminary communication.
Suh, Gil Joon; Park, Jaeheung; Lee, Jung Chan; Na, Sang Hoon; Kwon, Woon Yong; Kim, Kyung Su; Kim, Taegyun; Jung, Yoon Sun; Ko, Jung-In; Shin, So Mi; You, Kyoung Min
2018-06-01
Our aim was to compare the efficacy of the end-tidal CO 2 -guided automated robot CPR (robot CPR) system with manual CPR and mechanical device CPR. We developed the algorithm of the robot CPR system which automatically finds the optimal compression position under the guidance of end-tidal CO 2 feedback in swine models of cardiac arrest. Then, 18 pigs after 11 min of cardiac arrest were randomly assigned to one of three groups, robot CPR, LUCAS CPR, and manual CPR groups (n = 6 each group). Return of spontaneous circulation (ROSC) and Neurological Deficit Score 48 h after ROSC were compared. A ROSC was achieved in 5 pigs, 4 pigs, and 3 pigs in the robot CPR, LUCAS CPR, and manual CPR groups, respectively (p = 0.47). Robot CPR showed a significant difference in Neurological Deficit Score 48 h after ROSC compared to manual CPR, whereas LUCAS CPR showed no significant difference over manual CPR. (p = 0.01; Robot versus Manual adjusted p = 0.04, Robot versus LUCAS adjusted p = 0.07, Manual versus LUCAS adjusted p = 1.00). The end-tidal CO 2 -guided automated robot CPR system did not significantly improve ROSC rate in a swine model of cardiac arrest. However, robot CPR showed significant improvement of Neurological Deficit Score 48 h after ROSC compared to Manual CPR while LUCAS CPR showed no significant improvement compared to Manual CPR. Copyright © 2018 Elsevier B.V. All rights reserved.
Washburn, S P; White, S L; Green, J T; Benson, G A
2002-01-01
Dairy cows in confinement and pasture-based feeding systems were compared across four spring-calving and three fall-calving replicates for differences in reproduction, mastitis, body weights, and body condition scores. Feeding systems and replicates included both Jersey and Holstein cows. Cows in confinement were fed a total mixed ration, and cows on pasture were supplemented with concentrates and provided baled hay or haylage when pasture supply was limiting. Breeding periods were for 75 d in spring or fall. Reproductive performance did not differ significantly due to feeding system or season. Jerseys had higher conception rates (59.6 vs. 49.5 +/- 3.3%) and higher percentages of cows pregnant in 75 d (78.1 vs. 57.9 +/- 3.9%) than Holsteins. Cows in confinement had 1.8 times more clinical mastitis and eight times the rate of culling for mastitis than did cows on pasture. Jerseys had half as many clinical cases of mastitis per cow as Holsteins. Only 41 +/- 5% of confinement Holsteins remained for a subsequent lactation, starting within the defined calving season compared with 51 +/- 5% of pastured Holsteins and 71 and 72 +/- 5% of Jerseys, respectively. Body weights and condition scores were generally higher for confinement cows than pastured cows, and Jerseys had higher condition scores and lower body weights than Holsteins. In summary, pastured cows had fewer clinical cases of mastitis, lower body condition scores, and lower body weights than confinement cows. Holsteins were less likely to rebreed, had more mastitis, higher culling rates, and lower body condition scores than Jerseys.
ERIC Educational Resources Information Center
Lenkeit, Jenny; Caro, Daniel H.
2014-01-01
Reports of international large-scale assessments tend to evaluate and compare education system performance based on absolute scores. And policymakers refer to high-performing and economically prosperous education systems to enhance their own systemic features. But socioeconomic differences between systems compromise the plausibility of those…
Yaffe, Mark; Luo, Michael; Goyal, Nitin; Chan, Philip; Patel, Anay; Cayo, Max; Stulberg, S David
2014-09-01
The purpose of this study was to evaluate clinical, functional, and radiographic outcomes following total knee arthroplasty (TKA) performed with patient-specific instrumentation (PSI), computer-assisted surgery (CAS), and manual instruments at short-term follow-up. 122 TKAs were performed by a single surgeon: 42 with PSI, 38 with CAS, and 40 with manual instrumentation. Preoperative, 1-month, and 6-month clinical and functional outcomes were measured using the Knee Society scoring system (knee score, function score, range of motion, and pain score). Improvements in clinical and functional outcomes from the preoperative to postoperative period were analyzed. Preoperative and postoperative radiographs were measured to evaluate limb and component alignment. Preoperative, 1-month postoperative, and 6-month postoperative knee scores, function scores, range of motion, and pain scores were highest in the PSI group compared to CAS and manual instrumentation. At 6-month follow-up, PSI TKA was associated with a statistically significant improvement in functional score when compared to manual TKA. Otherwise, there were no statistically significant differences in improvements among PSI, CAS, and manual TKA groups. The higher preoperative scores in the PSI group limits the ability to draw definitive conclusions from the raw postoperative scores, but analyzing the changes in scores revealed that PSI was associated with a statistically significant improvement in Knee Society Functional score at 6-month post-TKA as compared to CAS or manual TKA. This may be attributable to improvements in component rotation and positioning, improved component size accuracy, or other factors that are not discernible on plain radiograph.
Fujimori, Takahito; Okuda, Shinya; Iwasaki, Motoki; Yamasaki, Ryoji; Maeno, Takafumi; Yamashita, Tomoya; Matsumoto, Tomiya; Wada, Eiji; Oda, Takenori
2016-06-01
The Japanese Orthopaedic Association (JOA) scoring system is a physician-based outcome that has been used to evaluate treatment effectiveness after lumbar surgery. However, patient-centered evaluation becomes increasingly important. There is no study that has examined the relationship between the JOA scoring system and patients' self-reported improvement. The purpose of the present study was to validate the JOA scoring system for assessment of patient-reported improvement after lumbar surgery. This is a retrospective review of prospectively collected data. The patient sample included 273 mail-in responders of the 466 consecutive patients who underwent posterior lumbar interbody fusion for spondylolisthesis between 1996 and 2008 in a single hospital. The outcome measures were the JOA scoring system and patients' self-reported improvement. Two hundred seventy three patients were divided into five anchoring groups based on self-reported improvement from "Much better" to "Much worse." Outcomes (ie, recovery rate, amount of change from preoperative condition, and postoperative score) based on the JOA scoring system were compared among groups. Using the patient's self-reported improvement scale as an anchor, the association among each of the outcomes was examined. The cutoff point and the area under the curve (AUC) that differentiated "Improved" from "Neither improved nor worse" was calculated using receiver operating characteristic (ROC) curve analysis. The recovery rate and postoperative score were significantly different in 9 of 10 pairs of anchoring groups. The amount of change was significantly different in six pairs. Spearman correlation coefficient for the 5-point scale anchors of patients' self-reported improvement was 0.20 (p=.001) for the baseline score, 0.31 (p<.001) for the amount of change, 0.55 (p<.001) for the recovery rate, and 0.56 (p<.001) for the postoperative score. According to ROC analysis, the best cutoff points and AUCs were 13 points and 0.69, respectively, for the amount of change, 67% and 0.73, respectively, for recovery rate, and 23 points and 0.72, respectively, for postoperative score. The JOA scoring system is a valid method for assessment of patients' self-reported improvement. Patients' self-reported improvement is more likely to be associated with the final condition, such as postoperative score or recovery rate, rather than the change from the preoperative condition. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of a Diagnostic Clinical Score for Hemodynamically Significant Patent Ductus Arteriosus
Kindler, Annemarie; Seipolt, Barbara; Heilmann, Antje; Range, Ursula; Rüdiger, Mario; Hofmann, Sigrun Ruth
2017-01-01
There is no consensus about the hemodynamic significance and, therefore, the need to treat a persistent ductus arteriosus in preterm newborns. Since the diagnosis of a hemodynamically significant persistent ductus arteriosus (hsPDA) is made by a summary of non-uniform echo-criteria in combination with the clinical deterioration of the preterm neonate, standardized clinical and ultrasound scoring systems are needed. The objective of this study was the development of a clinical score for the detection and follow-up of hsPDA. In this observational cohort study of 154 preterm neonates (mean gestational age 28.1 weeks), clinical signs for the development of hsPDA were recorded in a standardized score and compared to echocardiography. Analyzing the significance of single score parameters compared to the diagnosis by echocardiography, we developed a short clinical score (calculated sensitivity 84% and specificity 80%). In conclusion, this clinical diagnostic PDA score is non-invasive and quickly to implement. The continuous assessment of defined clinical parameters allows for a more precise diagnosis of hemodynamic significance of PDA and, therefore, should help to detect preterm neonates needing PDA-treatment. The score, therefore, allows a more targeted use of echocardiography in these very fragile preterm neonates. PMID:29312911
A nutrient profiling assessment of packaged foods using two star-based front-of-pack labels.
Carrad, Amy M; Louie, Jimmy Chun Yu; Yeatman, Heather R; Dunford, Elizabeth K; Neal, Bruce C; Flood, Victoria M
2016-08-01
To compare two front-of-pack nutrition labelling systems for the assessment of packaged foods and drinks with Australian Dietary Guidelines. A cross-sectional nutrient profiling assessment. Food and drink products (n 20 225) were categorised into scoring levels using criteria for the Institute of Medicine (IOM) three-star system and the five-star Australian Health Star Rating (HSR). The effectiveness of these systems to categorise foods in accordance with Australian Dietary Guidelines was explored. The study was conducted in Australia, using a comprehensive food database. Packaged food and drink products (n 20 225) available in Australia. Using the IOM three-star system, the majority (55 %) of products scored the minimum 0 points and 25·5 % scored the maximum 3 points. Using HSR criteria, the greatest proportion of products (15·2 %) scored three-and-a-half stars from a possible five and 12·5 % received the lowest rating of a half-star. Very few products (4·1 %) scored five stars. Products considered core foods and drinks in Australian Dietary Guidelines received higher scores than discretionary foods in all food categories for both labelling systems (all P<0·05; Mann-Whitney U test), with the exception of fish products using IOM three-star criteria (P=0·603). The largest discrepancies in median score between the two systems were for the food categories edible oils, convenience foods and dairy. Both the IOM three-star and Australian HSR front-of-pack labelling systems rated packaged foods and drinks broadly in line with Australian Dietary Guidelines by assigning core foods higher ratings and discretionary foods lower ratings.
Prognostic scores in oesophageal or gastric variceal bleeding.
Ohmann, C; Stöltzing, H; Wins, L; Busch, E; Thon, K
1990-05-01
Numerous scoring systems have been developed for the prediction of outcome of variceal bleeding; however, only a few have been evaluated adequately. The object of this study was to improve the classical Child-Pugh score (CPS) and to test other scores from the literature. Patients (n = 82) with endoscopically confirmed variceal bleeding and long-term sclerotherapy were included in the study. Linear logistic regression (LR) was applied to different sets of prognostic variables with regard to 30-day mortality. In addition, scores from the literature were evaluated on the data set. Performance was measured by the accuracy and receiver-operating characteristic curves. The application of LR to all five CPS variables (accuracy, 80%) was superior to the classical CPS (70%). LR with selection from the CPS variables or from other sets of variables resulted in no improvement. Compared with CPS only three scores from the literature, mainly based on subsets of the CPS variables, showed an improved accuracy. It is concluded that CPS is still a good scoring system; however, it can be improved by statistical analysis using the same variables.
Kalkan, Çağdaş; Soykan, Irfan; Karakaya, Fatih; Tüzün, Ali; Gençtürk, Zeynep Bıyıklı
2017-04-01
Acute gastrointestinal bleeding is a potentially life-threatening condition that requires rapid assessment and dynamic management. Several scoring systems are used to predict mortality and rebleeding in such cases. The aim of the present study was to compare three scoring systems for predicting short-term mortality, rebleeding, duration of hospitalization and the need for blood transfusion in elderly patients with upper gastrointestinal bleeding. The present study included 335 elderly patients with upper gastrointestinal bleeding. Pre- and post-endoscopic Rockall, Glasgow-Blatchford and AIMS65 scores were calculated. The ability of these scores to predict rebleeding, mortality, duration of hospitalization and the need for blood transfusion was determined. Pre- (4.5) and post-endoscopic (7.5) Rockall scores were superior to the Glasgow-Blatchford (12.5) score for predicting mortality (P = 0.006 and P = 0.015). Likewise, pre- (4.5) and post-endoscopic Rockall scores were superior to the respective Glasgow-Blatchford scores for predicting rebleeding (P = 0.013 and P = 0.03). There was an association between duration of hospitalization and mortality; as the duration of hospitalization increased the mortality rate increased. In all, 94% of patients hospitalized for a mean of 5 days were alive versus 56.1% of those hospitalized for 20 days, and 20.2% of those hospitalized for 40 days. In elderly patients with upper gastrointestinal bleeding, the Rockall score is clinically more useful for predicting mortality and rebleeding than the Glasgow-Blatchford and AIMS65 scores; however, for predicting duration of hospitalization and the need for blood transfusion, the Glasgow-Blatchford score is superior to the Rockall and AIMS65 scores. Geriatr Gerontol Int 2017; 17: 575-583. © 2016 Japan Geriatrics Society.
Peripheral nerve ultrasound scoring systems: benchmarking and comparative analysis.
Grimm, Alexander; Rattay, Tim W; Winter, Natalie; Axer, Hubertus
2017-02-01
Ultrasound of the nerves is an additive diagnostic tool to evaluate polyneuropathy. Recently, the need for standardized scoring systems has widely been discussed; different scores are described so far. Therefore, 327 patients with polyneuropathy were analyzed by ultrasound in our laboratory. Consequently, several ultrasound scoring tools were applied, i.e., the nerve pattern classification according to Padua et al. in all patients with CIDP and variants, the Bochum ultrasound score (BUS) and the neuritis ultrasound protocol in immune-mediated neuritis, the ultrasound pattern sum score, the homogeneity score, and the nerve enlargement distribution score in all neuropathies if possible. For all scores good accuracy was found. Most patients with CIDP revealed hypoechoic enlarged nerves (Class 1), the BUS/NUP was useful to identify GBS (sensitivity >85%), MMN (100%) and CIDP (>70%), while the UPSS showed high sensitivity and positive/negative predictive values (N/PPV) in the diagnosis of GBS (>70%), CIDP (>85%) and axonal non-inflammatory neuropathies (>90%). Homogeneous nerves were found in most CMT1 patients (66.7%), while immune-mediated neuropathies mostly show regional nerve enlargement. The HS was suitable to identify CMT patients with an HS ≥5 points. All scores were easily applicable with high accuracy. The former-reported results could be similarly confirmed. However, all sores have some incompleteness concerning unselected polyneuropathy population, particularly rare and focal types. Scoring systems are useful and easily applicable. They show high accuracy in certain neuropathies, but also offer some gaps and can, therefore, only be used in addition to standard diagnostic routines such as electrophysiology.
Conaghan, Philip G; Hunter, David J; Cohen, Stanley B; Kraus, Virginia B; Berenbaum, Francis; Lieberman, Jay R; Jones, Deryk G; Spitzer, Andrew I; Jevsevar, David S; Katz, Nathaniel P; Burgess, Diane J; Lufkin, Joelle; Johnson, James R; Bodick, Neil
2018-04-18
Intra-articular corticosteroids relieve osteoarthritis pain, but rapid systemic absorption limits efficacy. FX006, a novel, microsphere-based, extended-release triamcinolone acetonide (TA) formulation, prolongs TA joint residence and reduces systemic exposure compared with standard TA crystalline suspension (TAcs). We assessed symptomatic benefits and safety of FX006 compared with saline-solution placebo and TAcs. In this Phase-3, multicenter, double-blinded, 24-week study, adults ≥40 years of age with knee osteoarthritis (Kellgren-Lawrence grade 2 or 3) and average-daily-pain (ADP)-intensity scores of ≥5 and ≤9 (0 to 10 numeric rating scale) were centrally randomized (1:1:1) to a single intra-articular injection of FX006 (32 mg), saline-solution placebo, or TAcs (40 mg). The primary end point was change from baseline to week 12 in weekly mean ADP-intensity scores for FX006 compared with saline-solution placebo. Secondary end points were area-under-effect (AUE) curves of the change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with saline-solution placebo, AUE curves of the change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with TAcs, change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with TAcs, and AUE curves of the change in weekly mean ADP-intensity scores from baseline to week 24 for FX006 compared with saline-solution placebo. Exploratory end points included week-12 changes in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Injury and Osteoarthritis Outcome Score Quality of Life (KOOS-QOL) subscale scores for FX006 compared with saline-solution placebo and TAcs. Adverse events were elicited at each inpatient visit. The primary end point was met. Among 484 treated patients (n = 161 for FX006, n = 162 for saline-solution placebo, and n = 161 for TAcs), FX006 provided significant week-12 improvement in ADP intensity compared with that observed for saline-solution placebo (least-squares mean change from baseline: -3.12 versus -2.14; p < 0.0001) indicating ∼50% improvement. FX006 afforded improvements over saline-solution placebo for all secondary and exploratory end points (p < 0.05). Improvements in osteoarthritis pain were not significant for FX006 compared with TAcs using the ADP-based secondary measures. Exploratory analyses of WOMAC-A, B, and C and KOOS-QOL subscales favored FX006 (p ≤ 0.05). Adverse events were generally mild, occurring at similar frequencies across treatments. FX006 provided significant, clinically meaningful pain reduction compared with saline-solution placebo at week 12 (primary end point). Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Conaghan, Philip G.; Hunter, David J.; Cohen, Stanley B.; Kraus, Virginia B.; Berenbaum, Francis; Lieberman, Jay R.; Jones, Deryk G.; Spitzer, Andrew I.; Jevsevar, David S.; Katz, Nathaniel P.; Burgess, Diane J.; Lufkin, Joelle; Johnson, James R.; Bodick, Neil
2018-01-01
Background: Intra-articular corticosteroids relieve osteoarthritis pain, but rapid systemic absorption limits efficacy. FX006, a novel, microsphere-based, extended-release triamcinolone acetonide (TA) formulation, prolongs TA joint residence and reduces systemic exposure compared with standard TA crystalline suspension (TAcs). We assessed symptomatic benefits and safety of FX006 compared with saline-solution placebo and TAcs. Methods: In this Phase-3, multicenter, double-blinded, 24-week study, adults ≥40 years of age with knee osteoarthritis (Kellgren-Lawrence grade 2 or 3) and average-daily-pain (ADP)-intensity scores of ≥5 and ≤9 (0 to 10 numeric rating scale) were centrally randomized (1:1:1) to a single intra-articular injection of FX006 (32 mg), saline-solution placebo, or TAcs (40 mg). The primary end point was change from baseline to week 12 in weekly mean ADP-intensity scores for FX006 compared with saline-solution placebo. Secondary end points were area-under-effect (AUE) curves of the change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with saline-solution placebo, AUE curves of the change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with TAcs, change in weekly mean ADP-intensity scores from baseline to week 12 for FX006 compared with TAcs, and AUE curves of the change in weekly mean ADP-intensity scores from baseline to week 24 for FX006 compared with saline-solution placebo. Exploratory end points included week-12 changes in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Injury and Osteoarthritis Outcome Score Quality of Life (KOOS-QOL) subscale scores for FX006 compared with saline-solution placebo and TAcs. Adverse events were elicited at each inpatient visit. Results: The primary end point was met. Among 484 treated patients (n = 161 for FX006, n = 162 for saline-solution placebo, and n = 161 for TAcs), FX006 provided significant week-12 improvement in ADP intensity compared with that observed for saline-solution placebo (least-squares mean change from baseline: −3.12 versus −2.14; p < 0.0001) indicating ∼50% improvement. FX006 afforded improvements over saline-solution placebo for all secondary and exploratory end points (p < 0.05). Improvements in osteoarthritis pain were not significant for FX006 compared with TAcs using the ADP-based secondary measures. Exploratory analyses of WOMAC-A, B, and C and KOOS-QOL subscales favored FX006 (p ≤ 0.05). Adverse events were generally mild, occurring at similar frequencies across treatments. Conclusions: FX006 provided significant, clinically meaningful pain reduction compared with saline-solution placebo at week 12 (primary end point). Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. PMID:29664853
Wang, Hao; Li, Zhong; Yin, Mei; Chen, Xiao-Mei; Ding, Shi-Fang; Li, Chen; Zhai, Qian; Li, Yuan; Liu, Han; Wu, Da-Wei
2015-04-01
Given the high mortality rates in elderly patients with septic shock, the early recognition of patients at greatest risk of death is crucial for the implementation of early intervention strategies. Serum lactate and N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels are often elevated in elderly patients with septic shock and are therefore important biomarkers of metabolic and cardiac dysfunction. We hypothesized that a risk stratification system that incorporates the Acute Physiology and Chronic Health Evaluation (APACHE) II score and lactate and NT-proBNP biomarkers would better predict mortality in geriatric patients with septic shock than the APACHE II score alone. A single-center prospective study was conducted from January 2012 to December 2013 in a 30-bed intensive care unit of a triservice hospital. The lactate area score was defined as the sum of the area under the curve of serial lactate levels measured during the 24 hours following admission divided by 24. The NT-proBNP score was assigned based on NT-proBNP levels measured at admission. The combined score was calculated by adding the lactate area and NT-proBNP scores to the APACHE II score. Multivariate logistic regression analyses and receiver operating characteristic curves were used to evaluate which variables and scoring systems served as the best predictors of mortality in elderly septic patients. A total of 115 patients with septic shock were included in the study. The overall 28-day mortality rate was 67.0%. When compared to survivors, nonsurvivors had significantly higher lactate area scores, NT-proBNP scores, APACHE II scores, and combined scores. In the multivariate regression model, the combined score, lactate area score, and mechanical ventilation were independent risk factors associated with death. Receiver operating characteristic curves indicated that the combined score had significantly greater predictive power when compared to the APACHE II score or the NT-proBNP score (P < .05). A combined score that incorporates the APACHE II score with early lactate area and NT-proBNP levels is a useful method for risk stratification in geriatric patients with septic shock. Copyright © 2014 Elsevier Inc. All rights reserved.
Mizumoto, Kazuo; Morita, Eishin
2009-01-01
The aim of the present study was to predict operative morbidity in elderly patients with deep pressure sores by using the Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (POSSUM) scoring system. Fifteen patients over 70 years old were retrospectively reviewed who had undergone gluteus maximus fasciocutaneous flap-reconstruction for pressure sores of the sacral region from 1 April 2005 to 31 March 2007. Complications were seen in six cases (40%) after operation. Four were wound infection, one was chest infection and another was septicemia. The subjects were divided into two groups by the presence (complicated group) or absence (non-complicated group) of postoperative complications. Each item of physiological scores, physiological score (PS), operative severity score (OS) and predicted morbidity rate (R) were calculated and compared between two groups. As a result, hemoglobin (P = 0.0276), PS (P = 0.0023) and R (P = 0.0078) differed significantly between the two groups. It is noteworthy that the PS were over 25 in all of the complicated group, but in only one of nine in the non-complicated group (P = 0.0014). Our study suggests that, for pressure sores in the sacral region in elderly patients, gluteus maximus fasciocutaneous flap-reconstruction can be employed in patients whose PS are under 24 in the POSSUM scoring system.
Dong, Zhao; Nath, Anjali; Guo, Jing; Bhaumik, Urmi; Chin, May Y; Dong, Sherry; Marshall, Erica; Murphy, Johnna S; Sandel, Megan T; Sommer, Susan J; Ursprung, W W Sanouri; Woods, Elizabeth R; Reid, Margaret; Adamkiewicz, Gary
2018-01-01
To test the applicability of the Environmental Scoring System, a quick and simple approach for quantitatively measuring environmental triggers collected during home visits, and to evaluate its contribution to improving asthma outcomes among various child asthma programs. We pooled and analyzed data from multiple child asthma programs in the Greater Boston Area, Massachusetts, collected in 2011 to 2016, to examine the association of environmental scores (ES) with measures of asthma outcomes and compare the results across programs. Our analysis showed that demographics were important contributors to variability in asthma outcomes and total ES, and largely explained the differences among programs at baseline. Among all programs in general, we found that asthma outcomes were significantly improved and total ES significantly reduced over visits, with the total Asthma Control Test score negatively associated with total ES. Our study demonstrated that the Environmental Scoring System is a useful tool for measuring home asthma triggers and can be applied regardless of program and survey designs, and that demographics of the target population may influence the improvement in asthma outcomes.
Relapses vs. reactions in multibacillary leprosy: proposal of new relapse criteria.
Linder, Katharina; Zia, Mutaher; Kern, Winfried V; Pfau, Ruth K M; Wagner, Dirk
2008-03-01
To compare a new scoring system for multibacillary (MB) leprosy relapses, which combines time factor, risk factors and clinical presentation at relapse, to WHO criteria. Data were collected on all relapses diagnosed between 1998 and 2004 at the Marie-Adelaide-Centre in Karachi, Pakistan, including case histories, clinical manifestations, follow-up, bacterial indices, treatment and contacts. For the diagnosis of MB relapses a simple scoring system was developed and validated on a data-set of mouse foot pads (MFP)-confirmed relapses (Leprosy Reviews, 76, 2005, 241). Its sensitivity was further evaluated in the Karachi relapse cohort. The P-value was calculated with McNemar's test with continuity correction. The new scoring system that combines time factor, risk factors and clinical presentation at relapse had a higher sensitivity in MFP-confirmed relapses than the WHO-criteria (95%vs. 65%, P < 0.01). The sensitivity of the scoring system was also significantly higher than the WHO criteria in the 57 cases of MB-relapses diagnosed in Karachi (72%vs. 54%, P < 0.05). This new simple scoring system for diagnosing MB-relapses in leprosy should be further validated in a prospective study to confirm its superior sensitivity and to evaluate the specificity of these criteria by using MFP-confirmation for patients presenting with signs of activity after treatment.
A coupled duration-focused architecture for real-time music-to-score alignment.
Cont, Arshia
2010-06-01
The capacity for real-time synchronization and coordination is a common ability among trained musicians performing a music score that presents an interesting challenge for machine intelligence. Compared to speech recognition, which has influenced many music information retrieval systems, music's temporal dynamics and complexity pose challenging problems to common approximations regarding time modeling of data streams. In this paper, we propose a design for a real-time music-to-score alignment system. Given a live recording of a musician playing a music score, the system is capable of following the musician in real time within the score and decoding the tempo (or pace) of its performance. The proposed design features two coupled audio and tempo agents within a unique probabilistic inference framework that adaptively updates its parameters based on the real-time context. Online decoding is achieved through the collaboration of the coupled agents in a Hidden Hybrid Markov/semi-Markov framework, where prediction feedback of one agent affects the behavior of the other. We perform evaluations for both real-time alignment and the proposed temporal model. An implementation of the presented system has been widely used in real concert situations worldwide and the readers are encouraged to access the actual system and experiment the results.
Harrison, Allyson G; Armstrong, Irene T; Harrison, Laura E; Lange, Rael T; Iverson, Grant L
2014-12-01
Psychologists practicing in Canada must decide which set of normative data to use for the Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV). The purpose of this study was to compare the interpretive effects of applying American versus Canadian normative systems in a sample of 432 Canadian postsecondary-level students who were administered the WAIS-IV as part of an evaluation for a learning disability, attention-deficit hyperactivity disorder, or other mental health problems. Employing the Canadian normative system yielded IQ, Index, and subtest scores that were systematically lower than those obtained using the American norms. Furthermore, the percentage agreement in normative classifications, defined as American and Canadian index scores within five points or within the same classification range, was between 49% and 76%. Substantial differences are present between the American and Canadian WAIS-IV norms. Clinicians should consider carefully the implications regarding which normative system is most appropriate for specific types of evaluations. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Isaacs, Alex N; Walton, Alison M; Nisly, Sarah A
2015-04-25
To implement and evaluate interactive web-based learning modules prior to advanced pharmacy practice experiences (APPEs) on inpatient general medicine. Three clinical web-based learning modules were developed for use prior to APPEs in 4 health care systems. The aim of the interactive modules was to strengthen baseline clinical knowledge before the APPE to enable the application of learned material through the delivery of patient care. For the primary endpoint, postassessment scores increased overall and for each individual module compared to preassessment scores. Postassessment scores were similar among the health care systems. The survey demonstrated positive student perceptions of this learning experience. Prior to inpatient general medicine APPEs, web-based learning enabled the standardization and assessment of baseline student knowledge across 4 health care systems.
An online training-monitoring system to prevent nonfunctional overreaching.
Piacentini, Maria Francesca; Meeusen, Romain
2015-05-01
This longitudinal case study evaluated the effectiveness of an online training-monitoring system to prevent nonfunctional overreaching (NFOR). A female master track and field athlete was followed by means of a daily online training diary (www.spartanova.com) and a weekly profile of mood state (POMS). The online diary consists of objective training data and subjective feelings reported on a 10-cm visual analog scale. Furthermore, parameters that quantify and summarize training and adaptation to training were calculated. The novelty consists in the inclusion of a specific measuring parameter tested to detect NFOR (OR score). During track-season preparation, the athlete was facing some major personal changes, and extra training stress factors increased. Despite the fact that training load (TL) did not increase, the OR score showed a 222% and then a 997% increase compared with baseline. POMS showed a 167% increase in fatigue, a 38% decrease in vigor, a 32% increase in depression scores, and a total mood increase of 22%, with a 1-wk shift compared with the OR score. A 41% decrease in TL restored the OR score and POMS to baseline values within 10 d. The results demonstrate that immediate feedback obtained by "warning signals" to both athletes and coaches, based on individual baseline data, seems an optimal predictor of FOR/NFOR.
Yuan, Shaoxin; Gao, Yusong; Ji, Wenqing; Song, Junshuai; Mei, Xue
2018-05-01
The aim of this study was to assess the ability of acute physiology and chronic health evaluation II (APACHE II) score, poisoning severity score (PSS) as well as sequential organ failure assessment (SOFA) score combining with lactate (Lac) to predict mortality in the Emergency Department (ED) patients who were poisoned with organophosphate.A retrospective review of 59 stands-compliant patients was carried out. Receiver operating characteristic (ROC) curves were constructed based on the APACHE II score, PSS, SOFA score with or without Lac, respectively, and the areas under the ROC curve (AUCs) were determined to assess predictive value. According to SOFA-Lac (a combination of SOFA and Lac) classification standard, acute organophosphate pesticide poisoning (AOPP) patients were divided into low-risk and high-risk groups. Then mortality rates were compared between risk levels.Between survivors and non-survivors, there were significant differences in the APACHE II score, PSS, SOFA score, and Lac (all P < .05). The AUCs of the APACHE II score, PSS, and SOFA score were 0.876, 0.811, and 0.837, respectively. However, after combining with Lac, the AUCs were 0.922, 0.878, and 0.956, respectively. According to SOFA-Lac, the mortality of high-risk group was significantly higher than low-risk group (P < .05) and the patients of the non-survival group were all at high risk.These data suggest the APACHE II score, PSS, SOFA score can all predict the prognosis of AOPP patients. For its simplicity and objectivity, the SOFA score is a superior predictor. Lac significantly improved the predictive abilities of the 3 scoring systems, especially for the SOFA score. The SOFA-Lac system effectively distinguished the high-risk group from the low-risk group. Therefore, the SOFA-Lac system is significantly better at predicting mortality in AOPP patients.
Ouro-Koura, Abdou-Rahim; Sopoh, Emmanuel Ghislain; Sossa, Jerôme Charles; Glèlè-Ahanhanzo, Yolaine; Agueh, Victoire; Ouendo, Edgard-Marius; Ouedraogo, Laurent
2018-01-01
This study aimed to evaluate the performance of the logistics management system (LMS) of malaria control (MC) resources in the Littoral Department, Benin, in 2017. In June 2017, we conducted a cross-sectional evaluative study focusing on the structures for the storage and the disposal of MC resources as well as on staff involved in their management. The performance of the the logistics management system was evaluated on the basis of the observed compliance of the components and sub-components of the "Structure", the "Process" and the "Results" with the norms and standards defined by the Ministry of Health. A total of 36 structures were investigated and secondary target was surveyed. It followed that 52,78% of the structures for the storage and the disposal of MC resources met the requirements for resources storage while only 33.33% of MC resources management staff were trained in logistics management. The performance of the logistics management system of MC resources was inadequate (compliance 59,13 % compared to the expected score). The structure, as well as the process were non-compliant with the standards ( 60,20% and 73.22% compared to the expected score respectively), leading to negative results (41.53% compared to the expected score). The most inadequate sub-component was the logistics management information system (LMIS). This study highlights the role of LMS for better performance of MC resources management. Particular attention should be given to this component.
Developing a cumulative anatomic scoring system for military perineal and pelvic blast injuries.
Mossadegh, Somayyeh; Midwinter, M; Parker, P
2013-03-01
Improvised explosive device (IED) yields in Afghanistan have increased resulting in more proximal injuries. The injury severity score (ISS) is an anatomic aggregate score of the three most severely injured anatomical areas but does not accurately predict severity in IED related pelvi-perineal trauma patients. A scoring system based on abbreviated injury score (AIS) was developed to reflect the severity of these injuries in order to better understand risk factors, develop a tool for future audit and improve performance. Using standard AIS descriptors, injury scales were constructed for the pelvis (1, minor to 6, maximal). The perineum was divided into anterior and posterior zones as relevant to injury patterns and blast direction with each soft tissue structure being allocated a score from its own severity scale. A cumulative score, from 1 to 36 for soft tissue, or a maximum of 42 if a pelvic fracture was involved, was created for all structures injured in the anterior and posterior zones. Using this new scoring system, 77% of patients survived with a pelvi-perineal trauma score (PPTS) below 5. There was a significant increase in mortality, number of pelvic fractures and amputations with increase in score when comparing the first group (score 1-5) to the second group (score 6-10). For scores between 6 and 16 survival was 42% and 22% for scores between 17 and 21. In our cohort of 62 survivors, 1 patient with an IED related pelvi-perineal injury had a 'theoretically un-survivable' maximal ISS of 75 and survived, whereas there were no survivors with a PPTS greater than 22 but this group had no-one with an ISS of 75 suggesting ISS is not an accurate reflection of the true severity of pelvi-perineal blast injury. This scoring system is the initial part of a more complex logistic regression model that will contribute towards a unique trauma scoring system to aid surgical teams in predicting fluid requirements and operative timelines. In austere environments, it may also help to prevent futile resuscitations. Better correlation between measurement of severity and outcome would aid performance improvement monitoring. In the longer term it will also allow benchmarking of current survival rates and comparisons in the future.
Gratton, David G; Kwon, So Ran; Blanchette, Derek; Aquilino, Steven A
2016-01-01
The aim of this study was to evaluate the effect of digital tooth preparation imaging and evaluation technology on dental students' technical abilities, self-evaluation skills, and the assessment of their simulated clinical work. A total of 80 second-year students at one U.S. dental school were assigned to one of three groups: control (n=40), E4D Compare (n=20), and Sirona prepCheck (n=20). Students in the control group were taught by traditional teaching methodologies, and the technology-assisted groups received both traditional training and supplementary feedback from the corresponding digital system. Three outcomes were measured: faculty technical score, self-evaluation score, and E4D Compare scores at 0.30 mm tolerance. Correlations were determined between the groups' scores from visual assessment and self-evaluation and between the visual assessment and digital scores. The results showed that the visual assessment and self-evaluation scores did not differ among groups (p>0.05). Overall, correlations between visual and digital assessment scores were modest though statistically significant (5% level of significance). These results suggest that the use of digital tooth preparation evaluation technology did not impact the students' prosthodontic technical and self-evaluation skills. Visual scores given by faculty and digital assessment scores correlated moderately in only two instances.
Arneja, Jugpal S; Narasimhan, Kailash; Bouwman, David; Bridge, Patrick D
2009-12-01
In-training evaluations in graduate medical education have typically been challenging. Although the majority of standardized examination delivery methods have become computer-based, in-training examinations generally remain pencil-paper-based, if they are performed at all. Audience response systems present a novel way to stimulate and evaluate the resident-learner. The purpose of this study was to assess the outcomes of audience response systems testing as compared with traditional testing in a plastic surgery residency program. A prospective 1-year pilot study of 10 plastic surgery residents was performed using audience response systems-delivered testing for the first half of the academic year and traditional pencil-paper testing for the second half. Examination content was based on monthly "Core Quest" curriculum conferences. Quantitative outcome measures included comparison of pretest and posttest and cumulative test scores of both formats. Qualitative outcomes from the individual participants were obtained by questionnaire. When using the audience response systems format, pretest and posttest mean scores were 67.5 and 82.5 percent, respectively; using traditional pencil-paper format, scores were 56.5 percent and 79.5 percent. A comparison of the cumulative mean audience response systems score (85.0 percent) and traditional pencil-paper score (75.0 percent) revealed statistically significantly higher scores with audience response systems (p = 0.01). Qualitative outcomes revealed increased conference enthusiasm, greater enjoyment of testing, and no user difficulties with the audience response systems technology. The audience response systems modality of in-training evaluation captures participant interest and reinforces material more effectively than traditional pencil-paper testing does. The advantages include a more interactive learning environment, stimulation of class participation, immediate feedback to residents, and immediate tabulation of results for the educator. Disadvantages include start-up costs and lead-time preparation.
Bretterklieber, Agnes; Painsi, Clemens; Avian, Alexander; Wutte, Nora; Aberer, Elisabeth
2014-09-02
Systemic sclerosis (SSc) is a rare and potentially life threatening autoimmune disorder. The burden of disease compared to other dermatoses is unknown. The purpose of this study was to assess both the quality of life in patients with SSc and the variables that are associated with poor quality of life. Forty-one patients with systemic sclerosis (29 limited, 2 diffuse, 10 undifferentiated forms) were assessed with respect to their health status and compared to published data for the normal population, SSc patients from other studies, and patients with chronic skin diseases. For the most part, our SSc patients had better outcomes in all 8 dimensions of the SF-36 than SSc patients from other studies, and poorer scores than the healthy population and those with occupational contact dermatitis, ichthyosis, non-melanoma skin cancer, contact dermatitis, atopic eczema, chronic nail disease, vitiligo, health care workers with work-related disease, and those with other chronic skin diseases, but significantly better scores for mental health than those with nail disease, vitiligo, and health-care workers. Patients with atopic dermatitis, psoriasis and pemphigus had significantly poorer mean scores in social function and mental health than SSc patients. Patients with pemphigus were also significantly impaired in their physical and emotional roles. Patients with systemic lupus erythematosus (SLE) had the significantly poorest mean scores for QoL in all 8 domains except bodily pain and emotional role. Besides SLE, SSc is one of the most severe chronic dermatologic diseases in terms of reduced QoL. Since SSc cannot be cured, treatment strategies should include therapeutic interventions such as psychotherapy, social support, physiotherapy, and spiritual care. Their beneficial effects could be studied in future.
Koenecke, Christian; Göhring, Gudrun; de Wreede, Liesbeth C.; van Biezen, Anja; Scheid, Christof; Volin, Liisa; Maertens, Johan; Finke, Jürgen; Schaap, Nicolaas; Robin, Marie; Passweg, Jakob; Cornelissen, Jan; Beelen, Dietrich; Heuser, Michael; de Witte, Theo; Kröger, Nicolaus
2015-01-01
The aim of this study was to determine the impact of the revised 5-group International Prognostic Scoring System cytogenetic classification on outcome after allogeneic stem cell transplantation in patients with myelodysplastic syndromes or secondary acute myeloid leukemia who were reported to the European Society for Blood and Marrow Transplantation database. A total of 903 patients had sufficient cytogenetic information available at stem cell transplantation to be classified according to the 5-group classification. Poor and very poor risk according to this classification was an independent predictor of shorter relapse-free survival (hazard ratio 1.40 and 2.14), overall survival (hazard ratio 1.38 and 2.14), and significantly higher cumulative incidence of relapse (hazard ratio 1.64 and 2.76), compared to patients with very good, good or intermediate risk. When comparing the predictive performance of a series of Cox models both for relapse-free survival and for overall survival, a model with simplified 5-group cytogenetics (merging very good, good and intermediate cytogenetics) performed best. Furthermore, monosomal karyotype is an additional negative predictor for outcome within patients of the poor, but not the very poor risk group of the 5-group classification. The revised International Prognostic Scoring System cytogenetic classification allows patients with myelodysplastic syndromes to be separated into three groups with clearly different outcomes after stem cell transplantation. Poor and very poor risk cytogenetics were strong predictors of poor patient outcome. The new cytogenetic classification added value to prediction of patient outcome compared to prediction models using only traditional risk factors or the 3-group International Prognostic Scoring System cytogenetic classification. PMID:25552702
Maeremans, Joren; Spratt, James C; Knaapen, Paul; Walsh, Simon; Agostoni, Pierfrancesco; Wilson, William; Avran, Alexandre; Faurie, Benjamin; Bressollette, Erwan; Kayaert, Peter; Bagnall, Alan J; Smith, Dave; McEntegart, Margaret B; Smith, William H T; Kelly, Paul; Irving, John; Smith, Elliot J; Strange, Julian W; Dens, Jo
2018-02-01
This study sought to create a contemporary scoring tool to predict technical outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) from patients treated by hybrid operators with differing experience levels. Current scoring systems need regular updating to cope with the positive evolutions regarding materials, techniques, and outcomes, while at the same time being applicable for a broad range of operators. Clinical and angiographic characteristics from 880 CTO-PCIs included in the REgistry of CrossBoss and Hybrid procedures in FrAnce, the NetheRlands, BelGium and UnitEd Kingdom (RECHARGE) were analyzed by using a derivation and validation set (2:1 ratio). Variables significantly associated with technical failure in the multivariable analysis were incorporated in the score. Subsequently, the discriminatory capacity was assessed and the validation set was used to compare with the J-CTO score and PROGRESS scores. Technical success in the derivation and validation sets was 83% and 85%, respectively. Multivariate analysis identified six parameters associated with technical failure: blunt stump (beta coefficient (b) = 1.014); calcification (b = 0.908); tortuosity ≥45° (b = 0.964); lesion length 20 mm (b = 0.556); diseased distal landing zone (b = 0.794), and previous bypass graft on CTO vessel (b = 0.833). Score variables remained significant after bootstrapping. The RECHARGE score showed better discriminatory capacity in both sets (area-under-the-curve (AUC) = 0.783 and 0.711), compared to the J-CTO (AUC = 0.676) and PROGRESS (AUC = 0.608) scores. The RECHARGE score is a novel, easy-to-use tool for assessing the risk for technical failure in hybrid CTO-PCI and has the potential to perform well for a broad community of operators. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Fat-related dietary behaviors of adult Puerto Ricans, with and without diabetes, in New York City.
Melnik, Thomas A; Spence, Maureen M; Hosler, Akiko S
2006-09-01
To assess the fat-related dietary behaviors of adult Puerto Ricans with and without diagnosed diabetes, living in New York City. A random-digit-dialing telephone survey was conducted following Behavioral Risk Factor Surveillance System procedures. Dietary behavior was assessed using a brief Fat-Related Diet Habits Questionnaire, in which higher scores indicated higher fat intake. A total of 1,304 adult Puerto Ricans living in New York City were interviewed. Diabetes status was assessed using standard Behavioral Risk Factor Surveillance System questions. Weighted analyses using SUDAAN software for complex surveys were done, and t tests were used to assess differences in mean fat-related dietary score by sociodemographic and health characteristics. Age-adjusted least-squared means were used to compare scores between those with and without diabetes. Linear regression was used to model characteristics associated with fat-related dietary score. Fat-related dietary score was lower among those with diabetes and varied by population and health characteristics. Age-adjusted scores were significantly lower for those with diabetes who were younger, less educated, obese, or physically active. In the regression model, family history, weight, and exercise interacted with diabetes status. Those with diabetes were significantly more likely to modify meat consumption practices (eg, remove skin or trim fat) to reduce fat compared with those without diabetes. New York City Puerto Ricans with diabetes are somewhat more likely to engage in behaviors to reduce fat compared with those without diabetes. Targeted, culturally sensitive nutrition education and counseling emphasizing lower-fat food choices and other fat-reducing behaviors can help reduce risk and control diabetes. Education messages should be tailored to the individual's diabetes status and other health and sociodemographic characteristics.
Love, William J; Lehenbauer, Terry W; Kass, Philip H; Van Eenennaam, Alison L; Aly, Sharif S
2014-01-01
Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves.
Love, William J.; Lehenbauer, Terry W.; Kass, Philip H.; Van Eenennaam, Alison L.
2014-01-01
Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves. PMID:24482759
Inoue, Ayako; Oshita, Harumi; Maruyama, Yoshihiro; Tanaka, Yoshihiro; Ishitobi, Yoshinobu; Kawano, Aimi; Ikeda, Rie; Ando, Tomoko; Aizawa, Saeko; Masuda, Koji; Higuma, Haruka; Kanehisa, Masayuki; Ninomiya, Taiga; Akiyoshi, Jotaro
2015-07-30
Borderline personality disorder (BPD) is characterized by affective instability, unstable relationships, and identity disturbance. We measured salivary alpha-amylase (sAA) and salivary cortisol levels in all participants during exposure to the Trier Social Stress Test (TSST) and an electric stimulation stress. Seventy-two BPD patients were compared with 377 age- and gender- matched controls. The State and Trait versions of the Spielberger Anxiety Inventory test (STAI-S and STAI-T, respectively), the Profile of Mood State (POMS) tests, and the Beck Depression Inventory (BDI), the Depression and Anxiety Cognition Scale (DACS) were administered to participants before electrical stimulation. Following TSST exposure, salivary cortisol levels significantly decreased in female patients and significantly increased in male patients compared with controls. POMS tension-anxiety, depression-dejection, anger-hostility, fatigue, and confusion scores were significantly increased in BPD patients compared with controls. In contrast, vigor scores were significantly decreased in BPD patients relative to controls. Furthermore, STAI-T and STAI-S anxiety scores and BDI scores were significantly increased in BPD patient compared with controls. DACS scores were significantly increased in BPD patient compared with controls. Different stressors (e.g., psychological or physical) induced different responses in the HPA and SAM systems in female or male BPD patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rades, Dirk, E-mail: Rades.Dirk@gmx.net; Dziggel, Liesa; Haatanen, Tiina
2011-07-15
Purpose: To create and validate scoring systems for intracerebral control (IC) and overall survival (OS) of patients irradiated for brain metastases. Methods and Materials: In this study, 1,797 patients were randomly assigned to the test (n = 1,198) or the validation group (n = 599). Two scoring systems were developed, one for IC and another for OS. The scores included prognostic factors found significant on multivariate analyses. Age, performance status, extracerebral metastases, interval tumor diagnosis to RT, and number of brain metastases were associated with OS. Tumor type, performance status, interval, and number of brain metastases were associated with IC.more » The score for each factor was determined by dividing the 6-month IC or OS rate (given in percent) by 10. The total score represented the sum of the scores for each factor. The score groups of the test group were compared with the corresponding score groups of the validation group. Results: In the test group, 6-month IC rates were 17% for 14-18 points, 49% for 19-23 points, and 77% for 24-27 points (p < 0.0001). IC rates in the validation group were 19%, 52%, and 77%, respectively (p < 0.0001). In the test group, 6-month OS rates were 9% for 15-19 points, 41% for 20-25 points, and 78% for 26-30 points (p < 0.0001). OS rates in the validation group were 7%, 39%, and 79%, respectively (p < 0.0001). Conclusions: Patients irradiated for brain metastases can be given scores to estimate OS and IC. IC and OS rates of the validation group were similar to the test group demonstrating the validity and reproducibility of both scores.« less
Nakashima, Kazuaki; Ashizawa, Kazuto; Ochi, Makoto; Hashmi, Rashid; Hayashi, Kuniaki; Gotoh, Shinichi; Honda, Sumihisa; Igarashi, Akito; Komaki, Takao
2003-01-01
The purpose of this study was to investigate the usefulness of Fuji Computed Radiography (FCR) 5501D by comparing it with FCR 5000 and a screen‐film system (S/F). Posteroanterior chest radiographs often patients with no abnormality on chest CT scans were obtained with FCR 5501D, FCR 5000, and S/F. Six observers (three radiologists and three radio‐technologists) evaluated the visibility of nine normal anatomic structures (including lungs, soft tissue, and bones) and overall visibility on each image. Observers scored using a five‐point scale on each structure. FCR 5000 showed a significantly higher score in soft tissue and bone structures, and overall visibility compared with S/F, but, there was no significant difference between them in the visibility of all four normal lung structures. Compared with S/F, the score for FCR 5501D was higher in eight of the nine normal structures, including three of the four lung structures (unobscured lung, retrocardiac lung, and subdiaphragmatic lung), and overall visibility. Compared with FCR 5000, the score for FCR 5501D was higher in three normal structures, including two of the four lung structures (unobscured lung and subdiaphragmatic lung), and overall visibility. FCR 5501D was the best among the three techniques to visualize normal anatomic structures, particularly the obscured and unobscured lung. © 2003 American College of Medical Physics. PACS number(s): 87.57.–s, 87.62.+n PMID:12540822
Brennan, Gerard P; Hunter, Stephen J; Snow, Greg; Minick, Kate I
2017-12-01
The Centers for Medicare and Medicaid Services (CMS) require physical therapists document patients' functional limitations. The process is not standardized. A systematic approach to determine a patient's functional limitations and responsiveness to change is needed. The purpose of this study is to compare patient-reported outcomes (PROs) responsiveness to change using 7-level severity/complexity modifier scale proposed by Medicare to a derived scale implemented by Intermountain Healthcare's Rehabilitation Outcomes Management System (ROMS). This was a retrospective, observational cohort design. 165,183 PROs prior to July 1, 2013, were compared to 46,334 records from July 1, 2013, to December 31, 2015. Histograms and ribbon plots illustrate distribution and change of patients' scores. ROMS raw score ranges were calculated and compared to CMS' severity/complexity levels based on score percentage. Distribution of the population was compared based on the 2 methods. Sensitivity and specificity were compared for responsiveness to change based on minimal clinically important difference (MCID). Histograms demonstrated few patient scores placed in CMS scale levels at the extremes, whereas the majority of scores placed in 2 middle levels (CJ, CK). ROMS distributed scores more evenly across levels. Ribbon plots illustrated advantage of ROMS' using narrower score ranges. Greater chance for patients to change levels was observed with ROMS when an MCID was achieved. ROMS narrower scale levels resulted in greater sensitivity and good specificity. Geographic representation for the United States was limited. Without patients' global rating of change, a reference standard to gauge validation of improvement could not be provided. ROMS provides a standard approach to identify accurately functional limitation modifier levels and to detect improvement more accurately than a straight across transposition using the CMS scale. © 2017 American Physical Therapy Association
Ahmed, Emad; El-Menyar, Ayman
2016-03-01
The South Asian (SA) population constitutes one of the largest ethnic groups in the world. Several studies that compared host and migrant populations around the world indicate that SAs have a higher risk of developing cardiovascular disease (CVD) than their native-born counterparts. Herein, we review the literature to address the role of the screening tools, scoring systems, and guidelines for primary, secondary, and tertiary prevention in these populations. Management based on screening for the CVD risk factors in a high-risk population such as SAs can improve health care outcomes. There are many scoring tools for calculating 10-year CVD risk; however, each scoring system has its limitations in this particular ethnicity. Further work is needed to establish a unique scoring and guidelines in SAs. © The Author(s) 2015.
Chih, An-Hsuan; Su, Peijen; Hu, Wen-Yu; Yao, Chien-An; Cheng, Shao-Yi; Lin, Yen-Chun; Chiu, Tai-Yuan
2016-01-01
Abstract The current ethical dilemmas met by healthcare professionals were never compared with those 15 years ago when the palliative care system was newly developing in Taiwan. The aim of the study was to investigate the ethical dilemmas met by palliative care physicians and nurses in 2013 and compare the results with the survey in 1998. This cross-sectional study surveyed 213 physicians and nurses recruited from 9 representative palliative care units across Taiwan in 2013. The compared survey in 1998 studied 102 physicians and nurses from the same palliative care units. All participants took a questionnaire to survey the “frequency” and “difficulty” of 20 frequently encountered ethical dilemmas, which were grouped into 4 domains by factor analysis. The “ethical dilemma” scores were calculated and then compared across 15 years by Student's t tests. A general linear model analysis was used to identify significant factors relating to a high average “ethical dilemma” score in each domain. All of the highest-ranking ethical dilemmas in 2013 were related to insufficient resources. Physicians with less clinical experience had a higher average “ethical dilemma” score in clinical management. Physicians with dissatisfaction in providing palliative care were associated a higher average “ethical dilemma” score in communication. Nurses reported higher “ethical dilemma” scores in all items of resource allocation in 2013. Further analysis confirmed that, in 2013, nurses had a higher average “ethical dilemma” score in resource allocation after adjustment for other relating factors. Palliative care nursing staff in Taiwan are more troubled by ethical dilemmas related to insufficient resources than they were 15 years ago. Training of decision making in nurses under the framework of ethical principles and community palliative care programs may improve the problems. To promote the dignity of terminal cancer patients, long-term fundraising plans are recommended for countries in which the palliative care system is in its early stages of development. PMID:26735533
Chih, An-Hsuan; Su, Peijen; Hu, Wen-Yu; Yao, Chien-An; Cheng, Shao-Yi; Lin, Yen-Chun; Chiu, Tai-Yuan
2016-01-01
The current ethical dilemmas met by healthcare professionals were never compared with those 15 years ago when the palliative care system was newly developing in Taiwan. The aim of the study was to investigate the ethical dilemmas met by palliative care physicians and nurses in 2013 and compare the results with the survey in 1998. This cross-sectional study surveyed 213 physicians and nurses recruited from 9 representative palliative care units across Taiwan in 2013. The compared survey in 1998 studied 102 physicians and nurses from the same palliative care units. All participants took a questionnaire to survey the "frequency" and "difficulty" of 20 frequently encountered ethical dilemmas, which were grouped into 4 domains by factor analysis. The "ethical dilemma" scores were calculated and then compared across 15 years by Student's t tests. A general linear model analysis was used to identify significant factors relating to a high average "ethical dilemma" score in each domain. All of the highest-ranking ethical dilemmas in 2013 were related to insufficient resources. Physicians with less clinical experience had a higher average "ethical dilemma" score in clinical management. Physicians with dissatisfaction in providing palliative care were associated a higher average "ethical dilemma" score in communication. Nurses reported higher "ethical dilemma" scores in all items of resource allocation in 2013. Further analysis confirmed that, in 2013, nurses had a higher average "ethical dilemma" score in resource allocation after adjustment for other relating factors. Palliative care nursing staff in Taiwan are more troubled by ethical dilemmas related to insufficient resources than they were 15 years ago. Training of decision making in nurses under the framework of ethical principles and community palliative care programs may improve the problems. To promote the dignity of terminal cancer patients, long-term fundraising plans are recommended for countries in which the palliative care system is in its early stages of development.
Panahifar, A; Jaremko, J L; Tessier, A G; Lambert, R G; Maksymowych, W P; Fallone, B G; Doschak, M R
2014-10-01
We sought to develop a comprehensive scoring system for evaluation of pre-clinical models of osteoarthritis (OA) progression, and use this to evaluate two different classes of drugs for management of OA. Post-traumatic OA (PTOA) was surgically induced in skeletally mature rats. Rats were randomly divided in three groups receiving either glucosamine (high dose of 192 mg/kg) or celecoxib (clinical dose) or no treatment. Disease progression was monitored utilizing micro-magnetic resonance imaging (MRI), micro-computed tomography (CT) and histology. Pertinent features such as osteophytes, subchondral sclerosis, joint effusion, bone marrow lesion (BML), cysts, loose bodies and cartilage abnormalities were included in designing a sensitive multi-modality based scoring system, termed the rat arthritis knee scoring system (RAKSS). Overall, an inter-observer correlation coefficient (ICC) of greater than 0.750 was achieved for each scored feature. None of the treatments prevented cartilage loss, synovitis, joint effusion, or sclerosis. However, celecoxib significantly reduced osteophyte development compared to placebo. Although signs of inflammation such as synovitis and joint effusion were readily identified at 4 weeks post-operation, we did not detect any BML. We report the development of a sensitive and reliable multi-modality scoring system, the RAKSS, for evaluation of OA severity in pre-clinical animal models. Using this scoring system, we found that celecoxib prevented enlargement of osteophytes in this animal model of PTOA, and thus it may be useful in preventing OA progression. However, it did not show any chondroprotective effect using the recommended dose. In contrast, high dose glucosamine had no measurable effects. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
New prognostic factors and scoring system for patients with skeletal metastasis.
Katagiri, Hirohisa; Okada, Rieko; Takagi, Tatsuya; Takahashi, Mitsuru; Murata, Hideki; Harada, Hideyuki; Nishimura, Tetsuo; Asakura, Hirofumi; Ogawa, Hirofumi
2014-10-01
The aim of this study was to update a previous scoring system for patients with skeletal metastases, that was proposed by Katagiri et al. in 2005, by introducing a new factor (laboratory data) and analyzing a new patient cohort. Between January 2005 and January 2008, we treated 808 patients with symptomatic skeletal metastases. They were prospectively registered regardless of their treatments, and the last follow-up evaluation was performed in 2012. There were 441 male and 367 female patients with a median age of 64 years. Of these patients, 749 were treated nonsurgically while the remaining 59 underwent surgery for skeletal metastasis. A multivariate analysis was conducted using the Cox proportional hazards model. We identified six significant prognostic factors for survival, namely, the primary lesion, visceral or cerebral metastases, abnormal laboratory data, poor performance status, previous chemotherapy, and multiple skeletal metastases. The first three factors had a larger impact than the remaining three. The prognostic score was calculated by adding together all the scores for individual factors. With a prognostic score of ≥7, the survival rate was 27% at 6 months, and only 6% at 1 year. In contrast, patients with a prognostic score of ≤3 had a survival rate of 91% at 1 year, and 78% at 2 years. Comparing the revised system with the previous one, there was a significantly lower number of wrongly predicted patients using the revised system. This revised scoring system was able to predict the survival rates of patients with skeletal metastases more accurately than the previous system and may be useful for selecting an optimal treatment. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Milad, M P; Corfman, R S
1992-06-01
This review discusses advances in falloposcopy over the past 10 years. Refinements in instrumentation, including fiberoptics, have allowed visualization of the endosalpinx, a portion of the reproductive tract that has evaded endoscopic evaluation. A coaxial system of falloposcopic placement may give way to a linear everting catheter that does not require hysteroscopic guidance. Tubal endoscopic applications are discussed, including correlating hysterosalpingogram findings with those findings at salpingoscopy. Endosalpingeal changes can be quantitated in the presence of hydrosalpinges, and possibly with endometriosis. A scoring system to measure changes has been described. Using this scoring system, endosalpingeal findings at salpingoscopy have been compared with histologic and electron microscopic findings.
Evaluation of an inflammation-based prognostic score in patients with metastatic renal cancer.
Ramsey, Sara; Lamb, Gavin W A; Aitchison, Michael; Graham, John; McMillan, Donald C
2007-01-15
Recently, it was shown that an inflammation-based prognostic score, the Glasgow Prognostic Score (GPS), provides additional prognostic information in patients with advanced cancer. The objective of the current study was to examine the value of the GPS compared with established scoring systems in predicting cancer-specific survival in patients with metastatic renal cancer. One hundred nineteen patients who underwent immunotherapy for metastatic renal cancer were recruited. The Memorial Sloan-Kettering Cancer Center (MSKCC) score and the Metastatic Renal Carcinoma Comprehensive Prognostic System (MRCCPS) score were calculated as described previously. Patients who had both an elevated C-reactive protein level (>10 mg/L) and hypoalbuminemia (<35 g/L) were allocated a GPS of 2. Patients who had only 1 of those 2 biochemical abnormalities were allocated a GPS of 1. Patients who had neither abnormality were allocated a GPS of 0. On multivariate analysis of significant individual factors, only calcium (hazard ratio [HR], 3.21; 95% confidence interval [95% CI], 1.51-6.83; P = .002), white cell count (HR, 1.66; 95% CI, 1.17-2.35; P = .004), albumin (HR, 2.63; 95% CI, 1.38-5.03; P = .003), and C-reactive protein (HR, 2.85; 95% CI; 1.49-5.45; P = .002) were associated independently with cancer-specific survival. On multivariate analysis of the different scoring systems, the MSKCC (HR, 1.88; 95% CI, 1.22-2.88; P = .004), the MRCCPS (HR, 1.42; 95% CI, 0.97-2.09; P = .071), and the GPS (HR, 2.35; 95% CI, 1.51-3.67; P < .001) were associated independently with cancer-specific survival. An inflammation-based prognostic score (GPS) predicted survival independent of established scoring systems in patients with metastatic renal cancer.
Everard, Eoin M; Harrison, Andrew J; Lyons, Mark
2017-05-01
Everard, EM, Harrison, AJ, and Lyons, M. Examining the relationship between the functional movement screen and the landing error scoring system in an active, male collegiate population. J Strength Cond Res 31(5): 1265-1272, 2017-In recent years, there has been an increasing focus on movement screening as the principal aspect of preparticipation testing. Two of the most common movement screening tools are the Functional Movement Screen (FMS) and the Landing Error Scoring System (LESS). Several studies have examined the reliability and validity of these tools, but so far, there have been no studies comparing the results of these 2 screening tools against each other. Therefore, the purpose of this study was to determine the relationship between FMS scores and LESS scores. Ninety-eight male college athletes actively competing in sport (Gaelic games, soccer, athletics, boxing/mixed martial arts, Olympic weightlifting) participated in the study and performed the FMS and LESS screens. Both the 21-point and 100-point scoring systems were used to score the FMS. Spearman's correlation coefficients were used to determine the relationship between the 2 screening scores. The results showed a significant moderate correlation between FMS and LESS scores (rho 100 and 21 point = -0.528; -0.487; p < 0.001). In addition, r values of 0.26 and 0.23 indicate a poor shared variance between the 2 screens. The results indicate that performing well in one of the screens does not necessarily equate to performing well in the other. This has practical implications as it highlights that both screens may assess different movement patterns and should not be used as a substitute for each other.
Forecasting the value of credit scoring
NASA Astrophysics Data System (ADS)
Saad, Shakila; Ahmad, Noryati; Jaffar, Maheran Mohd
2017-08-01
Nowadays, credit scoring system plays an important role in banking sector. This process is important in assessing the creditworthiness of customers requesting credit from banks or other financial institutions. Usually, the credit scoring is used when customers send the application for credit facilities. Based on the score from credit scoring, bank will be able to segregate the "good" clients from "bad" clients. However, in most cases the score is useful at that specific time only and cannot be used to forecast the credit worthiness of the same applicant after that. Hence, bank will not know if "good" clients will always be good all the time or "bad" clients may become "good" clients after certain time. To fill up the gap, this study proposes an equation to forecast the credit scoring of the potential borrowers at a certain time by using the historical score related to the assumption. The Mean Absolute Percentage Error (MAPE) is used to measure the accuracy of the forecast scoring. Result shows the forecast scoring is highly accurate as compared to actual credit scoring.
[Cardiovascular risk by Framingham and SCORE in patients 40-65 years old].
González, Carmen; Rodilla, Enrique; Costa, José A; Justicia, Jorge; Pascual, José M
2006-04-15
The aim of this study was to compare the clinical and treatment implications of 2 cardiovascular risk stratification systems in a population of patients 40-65 years old. 929 non diabetic patients (40-65 years old) (51% female) with no evidence of previous cardiovascular disease were included in the study. The risk of cardiovascular death was assessed with the charts of the Systematic Coronary Risk Evaluation (SCORE), and coronary risk by the Framingham function (National Cholesterol Education Program Expert Panel on Detection, Evaluation and Treatment of High Blood Cholesterol in Adults -NCEP-ATP-III-). Patients were considered of high risk if risk of cardiovascular death was >or= 5% and coronary risk was > 20%, respectively. 4.1% of patients were considered as high risk by SCORE and 2.5% by Framingham. Only 0.2% of females were classified as high risk with either system. 8.2% and 4.8% of male population were considered as high risk by SCORE and Framingham, respectively. There was a low level of concordance between both systems. Patients classified as high risk by SCORE but not by Framingham were older, smoke less and had a better lipid profile. According to European Guidelines 28% of male and 23% of female were candidates to hypolipemic treatment, that proportion was higher, 43% of males and 28% of females, by NCEP-ATP-III guidelines. In Spanish patients 40-65 years old, SCORE charts almost duplicate the number of high risk individuals compared to Framingham. although the number of patients candidates to hypolipemic treatment is lower with the European than ATP-III guidelines. Differences were more evident in male.
The effect of obesity on the rate of heparin-induced thrombocytopenia.
Marler, Jacob L; Jones, G Morgan; Wheeler, Brian J; Alshaya, Abdulrahman; Hartmann, Jonathan L; Oliphant, Carrie S
2018-06-01
: Heparin-induced thrombocytopenia (HIT) occurs in patients receiving heparin-containing products due to the formation of platelet-activating antibodies to heparin and platelet factor 4. Diagnosis includes utilization of a scoring system known as the 4-T score, and HIT laboratory assays. Recently, obesity was identified as a potential factor associated with the development of HIT. The objective of this study was to evaluate the association of HIT with obesity in ICU and general medicine patients. We performed a chart review of adult patients within the Methodist Healthcare System, and included patients who had an ELISA and serotonin release assay laboratory tests reported within same hospital admission in which they also had documented receipt of heparin. Obese patients were compared with nonobese patients (BMI < 30) for the primary outcome of HIT occurrence, and secondary outcomes including rate of thrombosis, 4-T scores, and ELISA optical density values. We also generated a 5-T score by including one additional point for those with a BMI of 30 or more to determine the predictive value of this score in identifying HIT. Obesity was confirmed to be a risk factor for HIT, and the 5-T score model was also predictive of the development of HIT. However, the 5-T score was not statistically more predictive of HIT than the 4-T score. Predicting HIT remains challenging and novel markers of HIT are needed to improve HIT recognition. Although obesity did not improve the 4-T score, it may improve the predictability of other scoring systems, and further investigation is warranted.
Gatselis, Nikolaos K; Zachou, Kalliopi; Papamichalis, Panagiotis; Koukoulis, George K; Gabeta, Stella; Dalekos, George N; Rigopoulou, Eirini I
2010-11-01
The International Autoimmune Hepatitis Group developed a simplified score for autoimmune hepatitis. We assessed this "new scoring system" and compared it with the International Autoimmune Hepatitis Group original revised score. 502 patients were evaluated namely, 428 had liver diseases of various etiology [hepatitis B (n=109), hepatitis C (n=100), hepatitis D (n=4), alcoholic liver disease (n=28), non-alcoholic fatty liver disease (n=55), autoimmune cholestatic diseases (n=77), liver disorders of undefined origin (n=32) and miscellaneous hepatic disorders (n=23)], 13 had autoimmune hepatitis/overlap syndromes, 18 had autoimmune hepatitis/concurrent with other liver diseases and 43 had autoimmune hepatitis. The specificity of the simplified score was similar to that of the revised score (97% vs. 97.9%). The sensitivity in unmasking autoimmune hepatitis in autoimmune hepatitis/overlap syndromes was also similar in both systems (53.8% and 61.5%). However, the sensitivity for autoimmune hepatitis diagnosis in autoimmune hepatitis patients with concurrent liver disorders was lower by the new score (p=0.001). Liver biopsy proved to be the only independent factor for unmasking autoimmune hepatitis component among patients (p=0.003). The simplified score is a reliable and simple tool for excluding autoimmune hepatitis. However, both systems cannot unmask autoimmune hepatitis component efficiently in autoimmune hepatitis patients with concurrent autoimmune or non-autoimmune liver diseases. This study also strongly reiterates the importance of liver biopsy in the work-up of patients. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Francisco, C L; Cooke, R F; Marques, R S; Mills, R R; Bohnert, D W
2012-12-01
Two experiments evaluated the effects of temperament and acclimation to handling on performance of Angus × Hereford feeder cattle reared in extensive rangeland systems until weaning. In Exp. 1, 200 calves (n = 97 for yr 1; n = 103 for yr 2) were evaluated for temperament at weaning (average age ± SE = 152 ± 1 d) by chute score and exit velocity. Chute score was assessed on a 5-point scale according to behavior during chute restraining. Exit score was calculated by dividing exit velocity into quintiles and assigning calves a score from 1 (slowest) to 5 (fastest). A temperament score was calculated for each calf by averaging chute and exit scores. Calf temperament was classified according to temperament score as adequate (≤3) or excitable (>3). After weaning, calves were assigned to a 40-d preconditioning followed by growing (139 d) and finishing (117 d) phases until slaughter. Weaning BW was decreased (P = 0.04) in excitable calves compared with adequate calves. No differences were detected (P ≥ 0.21) for ADG during preconditioning, growing, and finishing phases; hence, excitable calves tended (P = 0.09) to have decreased HCW compared with adequate calves. In Exp. 2, 60 steers (initial age ± SE = 198 ± 2 d) were weighed and evaluated for temperament score 35 d after weaning (d -29). On d -28, steers were ranked by these variables and assigned to receive an acclimation treatment or not (control). Acclimated steers were processed through a handling facility twice weekly for 4 wk (d -28 to -1) whereas control steers remained undisturbed on pasture. On d 0, all steers were transported for 24 h and returned to the research facility (d 1). On arrival, steers were ranked by BW within treatment and randomly assigned to 20 feedlot pens for a 28-d feedlot receiving period. Acclimated steers had decreased temperament score and plasma cortisol compared with controls on d 0 (P = 0.02). During feedlot receiving, acclimated steers had decreased ADG (P < 0.01) and G:F (P = 0.03) and tended to have decreased DMI (P = 0.07) compared with controls. Acclimated steers had greater plasma haptoglobin on d 4 (P = 0.04) and greater ceruloplasmin from d 0 to 10 (P ≤ 0.04) and tended to have greater cortisol on d 1 (P = 0.08) than controls. In conclusion, temperament affects productivity of beef operations based on Bos taurus feeder cattle reared in extensive rangeland systems until weaning whereas acclimation to handling ameliorated cattle temperament but did not benefit feedlot receiving performance.
Kuselman, Ilya; Pennecchi, Francesca; Epstein, Malka; Fajgelj, Ales; Ellison, Stephen L R
2014-12-01
Monte Carlo simulation of expert judgments on human errors in a chemical analysis was used for determination of distributions of the error quantification scores (scores of likelihood and severity, and scores of effectiveness of a laboratory quality system in prevention of the errors). The simulation was based on modeling of an expert behavior: confident, reasonably doubting and irresolute expert judgments were taken into account by means of different probability mass functions (pmfs). As a case study, 36 scenarios of human errors which may occur in elemental analysis of geological samples by ICP-MS were examined. Characteristics of the score distributions for three pmfs of an expert behavior were compared. Variability of the scores, as standard deviation of the simulated score values from the distribution mean, was used for assessment of the score robustness. A range of the score values, calculated directly from elicited data and simulated by a Monte Carlo method for different pmfs, was also discussed from the robustness point of view. It was shown that robustness of the scores, obtained in the case study, can be assessed as satisfactory for the quality risk management and improvement of a laboratory quality system against human errors. Copyright © 2014 Elsevier B.V. All rights reserved.
Contreras-Omaña, R; Alfaro-Reynoso, J A; Cruz-Chávez, C E; Velarde-Ruiz Velasco, A; Flores-Ramírez, D I; Romero-Hernández, I; Donato-Olguín, I; García-Samper, X; Bautista-Santos, A; Reyes-Bastidas, M; Millán-Marín, E
The predictive scale for mortality risk in patients with nonvariceal upper gastrointestinal bleeding (NVUGIB) proposed by Italy's PNED (Progetto Nazionale Emorragia Digestiva) group has not been validated in Latin America since its original publication. To compare the PNED system and the Rockall score as mortality predictors in patients hospitalized for NVUGIB. A multicenter, prospective, cross-sectional, analytic study was conducted that recruited patients diagnosed with nonvariceal upper gastrointestinal bleeding within the time frame of 2011 to 2015. Six Mexican hospital centers participated in the study. The Rockall and PNED system scores were calculated, classifying the patients as having mild, moderate, or severe disease. The association between mortality and risk was determined through the chi-square test and relative risk (RR) calculation. Statistical significance was set at a P<.05. Information on 198 patients was collected. Only 8 patients (4%) died from causes directly associated with bleeding. According to the Rockall score, 46 patients had severe disease (23.2%), 5 of whom died, with a RR of 5.5 (CI 1.35-22.02, P=.006). In relation to the PNED, only 8 patients had severe disease (4%), 5 of whom died, with a RR of 38.7 (CI 11.4-137.3, P=.001). The PNED system was more selective for classifying a case as severe, but it had a greater predictive capacity for mortality, compared with the Rockall score. Copyright © 2016 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Wasano, K; Ishikawa, T; Kawasaki, T; Yamamoto, S; Tomisato, S; Shinden, S; Minami, S; Wakabayashi, T; Ogawa, K
2017-12-01
We describe a novel scoring system, the facial Palsy Prognosis Prediction score (PPP score), which we test for reliability in predicting pre-therapeutic prognosis of facial palsy. We aimed to use readily available patient data that all clinicians have access to before starting treatment. Multicenter case series with chart review. Three tertiary care hospitals. We obtained haematological and demographic data from 468 facial palsy patients who were treated between 2010 and 2014 in three tertiary care hospitals. Patients were categorised as having Bell's palsy or Ramsey Hunt's palsy. We compared the data of recovered and unrecovered patients. PPP scores consisted of combinatorial threshold values of continuous patient data (eg platelet count) and categorical variables (eg gender) that best predicted recovery. We created separate PPP scores for Bell's palsy patients (PPP-B) and for Ramsey Hunt's palsy patients (PPP-H). The PPP-B score included age (≥65 years), gender (male) and neutrophil-to-lymphocyte ratio (≥2.9). The PPP-H score included age (≥50 years), monocyte rate (≥6.0%), mean corpuscular volume (≥95 fl) and platelet count (≤200 000 /μL). Patient recovery rate significantly decreased with increasing PPP scores (both PPP-B and PPP-H) in a step-wise manner. PPP scores (ie PPP-B score and PPP-H score) ≥2 were associated with worse than average prognosis. Palsy Prognosis Prediction scores are useful for predicting prognosis of facial palsy before beginning treatment. © 2017 John Wiley & Sons Ltd.
Computer-enhanced laparoscopic training system (CELTS): bridging the gap.
Stylopoulos, N; Cotin, S; Maithel, S K; Ottensmeye, M; Jackson, P G; Bardsley, R S; Neumann, P F; Rattner, D W; Dawson, S L
2004-05-01
There is a large and growing gap between the need for better surgical training methodologies and the systems currently available for such training. In an effort to bridge this gap and overcome the disadvantages of the training simulators now in use, we developed the Computer-Enhanced Laparoscopic Training System (CELTS). CELTS is a computer-based system capable of tracking the motion of laparoscopic instruments and providing feedback about performance in real time. CELTS consists of a mechanical interface, a customizable set of tasks, and an Internet-based software interface. The special cognitive and psychomotor skills a laparoscopic surgeon should master were explicitly defined and transformed into quantitative metrics based on kinematics analysis theory. A single global standardized and task-independent scoring system utilizing a z-score statistic was developed. Validation exercises were performed. The scoring system clearly revealed a gap between experts and trainees, irrespective of the task performed; none of the trainees obtained a score above the threshold that distinguishes the two groups. Moreover, CELTS provided educational feedback by identifying the key factors that contributed to the overall score. Among the defined metrics, depth perception, smoothness of motion, instrument orientation, and the outcome of the task are major indicators of performance and key parameters that distinguish experts from trainees. Time and path length alone, which are the most commonly used metrics in currently available systems, are not considered good indicators of performance. CELTS is a novel and standardized skills trainer that combines the advantages of computer simulation with the features of the traditional and popular training boxes. CELTS can easily be used with a wide array of tasks and ensures comparability across different training conditions. This report further shows that a set of appropriate and clinically relevant performance metrics can be defined and a standardized scoring system can be designed.
Kellett, John; Murray, Alan
2016-05-01
few studies have compared the discrimination of predictive scores of in-hospital mortality that used vital signs with those using laboratory results in different patient populations. a hypothesis generating retrospective observational cohort study. A score that only used vital signs was compared with three other scores that used laboratory changes in 44,985 medical and 20,432 surgical patients. the discrimination of the score based only on vital signs was highest for the prediction of in-hospital death within 24h. In contrast the, albeit lower, discrimination of scores based only on laboratory data remained constant for the prediction of death up to 30 days after hospital admission. Moreover, the discrimination of scores based only on laboratory data was higher in surgical than in medical patients. in acutely ill medical patients a vital sign based score appears to predict mortality within 24h better than scores using laboratory data. This may be because in acutely ill patients vital sign changes indicate how well a patient is responding to a current insult. In contrast, for patients without acute illness laboratory data may be a more valuable indication of the patient's capacity to respond to insults in the future. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Have Nursing Home Compare quality measure scores changed over time in response to competition?
Castle, Nicholas G; Engberg, John; Liu, Darren
2007-06-01
Currently, the Centers for Medicare and Medicaid Services report on 15 Quality Measures (QMs) on the Nursing Home Compare (NHC) website. It is assumed that nursing homes are able to make improvements on these QMs, and in doing so they will attract more residents. In this investigation, we examine changes in QM scores, and whether competition and/or excess demand have influenced these change scores over a period of 1 year. Data come from NHC and the On-line Survey Certification And Recording (OSCAR) system. QM change scores are calculated using values from January 2003 to January 2004. A series of regression analyses are used to examine the association of competition and excess demand on QM scores. Eight QMs show an average decrease in scores (ie, better quality) and six QMs show an average increase in scores (ie, worse quality). However, for 13 of the 14 QMs these average changes averaged less than 1%. The regression analyses show an association between higher competition and improving QM scores and an association between lower occupancy and improving QM scores. As would be predicted based on the market-driven mechanism underlying quality improvements using report cards, we show that it is in the most competitive markets and those with the lowest average occupancy rates that improvements in the QM scores are more likely.
Shaikh, Mohammad-Ali; Jeong, Haneol S; Mastro, Andrew; Davis, Kathryn; Lysikowski, Jerzy; Kenkel, Jeffrey M
2016-04-01
Venous thromboembolism (VTE) can be a fatal outcome of plastic surgery. Risk assessment models attempt to determine a patient's risk, yet few studies have compared different models in plastic surgery patients. The authors investigated preoperative ASA physical status and 2005 Caprini scores to determine which model was more predictive of VTE. A retrospective chart review examined 1801 patients undergoing contouring and reconstructive procedures from January 2008 to January 2012. Patients were grouped into risk tiers for ASA scores (1-2 = low, 3+ = high) with 2 cutoffs for Caprini scores (1-4 = low, 5+ high; 1-5 = low, 6+ = high), then re-stratified into 3 tiers using Caprini score cutoffs (1-4 = low, 5-8 = high, 9+ = highest; 1-5 = low, 6-8 = high, 9+ = highest). Median scores of VTE patients were compared to those without VTE. Odds ratio and chi-squared analyses were performed. Of the 1598 patients included in the study, 1.50% developed VTE. Median ASA scores differed significantly between comparison groups but Caprini scores did not vary regardless of cutoff. When examining the 2-tiered Caprini scores, using low risk = 1-5 showed a significant relationship between risk tier and DVT development (P = 0.0266). The ASA system yielded the highest odds ratio of VTE development between low and high-risk patients. The Caprini model captured more patients with VTE in its high-risk category. Combining the two models for a more heuristic approach to preoperative care may identify patients at higher risk. 4 Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
Hays, Ron D; Spritzer, Karen L; Amtmann, Dagmar; Lai, Jin-Shei; Dewitt, Esi Morgan; Rothrock, Nan; Dewalt, Darren A; Riley, William T; Fries, James F; Krishnan, Eswar
2013-11-01
To create upper-extremity and mobility subdomain scores from the Patient-Reported Outcomes Measurement Information System (PROMIS) physical functioning adult item bank. Expert reviews were used to identify upper-extremity and mobility items from the PROMIS item bank. Psychometric analyses were conducted to assess empirical support for scoring upper-extremity and mobility subdomains. Data were collected from the U.S. general population and multiple disease groups via self-administered surveys. The sample (N=21,773) included 21,133 English-speaking adults who participated in the PROMIS wave 1 data collection and 640 Spanish-speaking Latino adults recruited separately. Not applicable. We used English- and Spanish-language data and existing PROMIS item parameters for the physical functioning item bank to estimate upper-extremity and mobility scores. In addition, we fit graded response models to calibrate the upper-extremity items and mobility items separately, compare separate to combined calibrations, and produce subdomain scores. After eliminating items because of local dependency, 16 items remained to assess upper extremity and 17 items to assess mobility. The estimated correlation between upper extremity and mobility was .59 using existing PROMIS physical functioning item parameters (r=.60 using parameters calibrated separately for upper-extremity and mobility items). Upper-extremity and mobility subdomains shared about 35% of the variance in common, and produced comparable scores whether calibrated separately or together. The identification of the subset of items tapping these 2 aspects of physical functioning and scored using the existing PROMIS parameters provides the option of scoring these subdomains in addition to the overall physical functioning score. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Psoriasis image representation using patch-based dictionary learning for erythema severity scoring.
George, Yasmeen; Aldeen, Mohammad; Garnavi, Rahil
2018-06-01
Psoriasis is a chronic skin disease which can be life-threatening. Accurate severity scoring helps dermatologists to decide on the treatment. In this paper, we present a semi-supervised computer-aided system for automatic erythema severity scoring in psoriasis images. Firstly, the unsupervised stage includes a novel image representation method. We construct a dictionary, which is then used in the sparse representation for local feature extraction. To acquire the final image representation vector, an aggregation method is exploited over the local features. Secondly, the supervised phase is where various multi-class machine learning (ML) classifiers are trained for erythema severity scoring. Finally, we compare the proposed system with two popular unsupervised feature extractor methods, namely: bag of visual words model (BoVWs) and AlexNet pretrained model. Root mean square error (RMSE) and F1 score are used as performance measures for the learned dictionaries and the trained ML models, respectively. A psoriasis image set consisting of 676 images, is used in this study. Experimental results demonstrate that the use of the proposed procedure can provide a setup where erythema scoring is accurate and consistent. Also, it is revealed that dictionaries with large number of atoms and small patch sizes yield the best representative erythema severity features. Further, random forest (RF) outperforms other classifiers with F1 score 0.71, followed by support vector machine (SVM) and boosting with 0.66 and 0.64 scores, respectively. Furthermore, the conducted comparative studies confirm the effectiveness of the proposed approach with improvement of 9% and 12% over BoVWs and AlexNet based features, respectively. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Warren, Johanna B; Hamilton, Andrew
2015-12-01
Seven validated prospective scoring systems, and one unvalidated system, predict a successful TOLAC based on a variety of clinical factors. The systems use different outcome statistics, so their predictive accuracy can't be directly compared.
Gagliardi, Filippo; Boari, Nicola; Roberti, Fabio; Caputy, Anthony J; Mortini, Pietro
2014-09-01
Comparative anatomical studies have proved to be invaluable in the evaluation of advantages and drawbacks of single approaches to access established target areas. Approach-related exposed areas do not necessarily represent useful areas when performing surgical manoeuvres. Accordingly the concept of "operability" has recently been introduced as a qualitative assessment of the ability to execute surgical manoeuvres. The authors propose an innovative model for the quantitative assessment of the operability, defined as "operability score" (OS), which can be effectively and easily applied to comparative studies on surgical anatomy. A microanatomical study was conducted on six cadaveric heads. Morphometric measurements were collected and operability scores in selected target points of the surgical field were calculated. As illustrative example, the operability score was applied to the extradural subtemporal transzygomatic approach (ESTZ). The operability score is effective in grading system of surgical operability, and instruments manipulation capability. It is a useful tool to evaluate, in a single approach, areas that can be exposed, and to quantify how those areas are suitable for surgical manoeuvres. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
A comparison of two patient classification instruments in an acute care hospital.
Seago, Jean Ann
2002-05-01
Patient classification systems are alternately praised and vilified by staff nurses, nurse managers, and nurse executives. Most nurses agree that substantial resources are used to create or find, implement, manage, and maintain the systems, and that the predictive ability of the instruments is intermittent. The purpose of this study is to compare the predictive validity of two types of patient classification instruments commonly used in acute care hospitals in California. Acute care hospitals in California are required by both the Joint Commission on Accreditation of Healthcare Organizations and California Title 22 to have a reliable and valid patient classification system (PCS). The two general types of systems commonly used are the summative task type PCS and the critical incident or criterion type PCS. There is little to assist nurse executives in deciding which type of PCS to choose. There is modest research demonstrating the validity and reliability of different PCSs but no published data comparing the predictive validity of the different types of systems. The unit of analysis is one patient shift called the study shift. The study shift is defined as the first day shift after the patient has been in the hospital for a full 24 hours. Data were collected using medical record review only. Both types, criterion and summative, of PCS data collection instruments were completed for all patients at both collection points. Each patient had a before and after score for each type of instrument. Three hundred forty-nine medical records for inpatients meeting the inclusion criteria were examined. The average patient age was 76 years, the average length of stay was 6.6 days with an average of 6.7 secondary diagnoses recorded. Fifty-five percent of the sample was female and the most common primary diagnosis was CHF, followed by COPD, CVA, and pneumonia. There was a difference in mean summative predictor score and the mean summative actual score of 1.57 points with the predictor score higher (P =.001; CI =.62--2.5). For the criterion instrument, 68.4% of the predictor criterion scores were in category 2 compared to 65.5% of the actual criterion scores. The criterion predictor agreed with the criterion actual score 45% of the time for category 1 patients, 87.3% of the time for category 2 patients, 77.1% of the time for category 3 patients and 72.7% of the time for category 4 patients, with an overall agreement between predictor and actual criterion scores of 79.9% (Kappa P <.001, indicating agreement is not by chance). The most significant finding of this study is that there are virtually no differences in the predictive ability of summative versus criterion patient classification instruments. Using the same patients, both types of instruments predicted the actual score over 78% of the time.
ERIC Educational Resources Information Center
Pruett, Sharon M.
2012-01-01
The objective of this study was to compare the relationships between the subtests of the Interactive Computer Interview System and the ETS "Praxis II" Principles of Learning and Teaching examination. In particular, this study compares scores on the ICIS instrument subtests to those gathered from the same classroom teachers on the…
Bhargava, Rahul; Kumar, Prachi; Kaur, Avinash; Kumar, Manjushri; Mishra, Anurag
2014-07-01
To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. A case-control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R (2)) of 0.5 or more was statistically significant. The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls (P < 0.001). Mean TBUT, Schirmer's test values, and goblet cell density were significantly reduced in computer users (P < 0.001). TBUT, Schirmer's, and CIC were abnormal in 48.5%, 29.1%, and 38.4% symptomatic computer users respectively as compared to 8%, 6.7%, and 7.3% symptomatic controls respectively. On correlation analysis, there was a significant (inverse) association of dry eye symptoms (DESS) with TBUT and CIC scores (R (2) > 0.5), in contrast to Schirmer's scores (R(2) < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users.
Iyer, Hari S; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R; Drobac, Peter C
2015-01-01
While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level.
Iyer, Hari S.; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R.; Drobac, Peter C.
2015-01-01
Background While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. Design The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. Results We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Conclusions Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level. PMID:26140729
Stanley, Adrian J; Laine, Loren; Dalton, Harry R; Ngu, Jing H; Schultz, Michael; Abazi, Roseta; Zakko, Liam; Thornton, Susan; Wilkinson, Kelly; Khor, Cristopher J L; Murray, Iain A; Laursen, Stig B
2017-01-04
To compare the predictive accuracy and clinical utility of five risk scoring systems in the assessment of patients with upper gastrointestinal bleeding. International multicentre prospective study. Six large hospitals in Europe, North America, Asia, and Oceania. 3012 consecutive patients presenting over 12 months with upper gastrointestinal bleeding. Comparison of pre-endoscopy scores (admission Rockall, AIMS65, and Glasgow Blatchford) and post-endoscopy scores (full Rockall and PNED) for their ability to predict predefined clinical endpoints: a composite endpoint (transfusion, endoscopic treatment, interventional radiology, surgery, or 30 day mortality), endoscopic treatment, 30 day mortality, rebleeding, and length of hospital stay. Optimum score thresholds to identify low risk and high risk patients were determined. The Glasgow Blatchford score was best (area under the receiver operating characteristic curve (AUROC) 0.86) at predicting intervention or death compared with the full Rockall score (0.70), PNED score (0.69), admission Rockall score (0.66, and AIMS65 score (0.68) (all P<0.001). A Glasgow Blatchford score of ≤1 was the optimum threshold to predict survival without intervention (sensitivity 98.6%, specificity 34.6%). The Glasgow Blatchford score was better at predicting endoscopic treatment (AUROC 0.75) than the AIMS65 (0.62) and admission Rockall scores (0.61) (both P<0.001). A Glasgow Blatchford score of ≥7 was the optimum threshold to predict endoscopic treatment (sensitivity 80%, specificity 57%). The PNED (AUROC 0.77) and AIMS65 scores (0.77) were best at predicting mortality, with both superior to admission Rockall score (0.72) and Glasgow Blatchford score (0.64; P<0.001). Score thresholds of ≥4 for PNED, ≥2 for AIMS65, ≥4 for admission Rockall, and ≥5 for full Rockall were optimal at predicting death, with sensitivities of 65.8-78.6% and specificities of 65.0-65.3%. No score was helpful at predicting rebleeding or length of stay. The Glasgow Blatchford score has high accuracy at predicting need for hospital based intervention or death. Scores of ≤1 appear the optimum threshold for directing patients to outpatient management. AUROCs of scores for the other endpoints are less than 0.80, therefore their clinical utility for these outcomes seems to be limited.Trial registration Current Controlled Trials ISRCTN16235737. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H.; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A. N.; Lübbert, Michael; Greenberg, Peter L.; Bennett, John M.; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L.; Ohyashiki, Kazuma; Le Beau, Michelle M.; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R.; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie
2015-01-01
International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%–20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34+) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34+ peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34+ blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). PMID:25344522
Ogura, Takayuki; Nakamura, Yoshihiko; Nakano, Minoru; Izawa, Yoshimitsu; Nakamura, Mitsunobu; Fujizuka, Kenji; Suzukawa, Masayuki; Lefor, Alan T
2014-05-01
The ability to easily predict the need for massive transfusion may improve the process of care, allowing early mobilization of resources. There are currently no clear criteria to activate massive transfusion in severely injured trauma patients. The aims of this study were to create a scoring system to predict the need for massive transfusion and then to validate this scoring system. We reviewed the records of 119 severely injured trauma patients and identified massive transfusion predictors using statistical methods. Each predictor was converted into a simple score based on the odds ratio in a multivariate logistic regression analysis. The Traumatic Bleeding Severity Score (TBSS) was defined as the sum of the component scores. The predictive value of the TBSS for massive transfusion was then validated, using data from 113 severely injured trauma patients. Receiver operating characteristic curve analysis was performed to compare the results of TBSS with the Trauma-Associated Severe Hemorrhage score and the Assessment of Blood Consumption score. In the development phase, five predictors of massive transfusion were identified, including age, systolic blood pressure, the Focused Assessment with Sonography for Trauma scan, severity of pelvic fracture, and lactate level. The maximum TBSS is 57 points. In the validation study, the average TBSS in patients who received massive transfusion was significantly greater (24.2 [6.7]) than the score of patients who did not (6.2 [4.7]) (p < 0.01). The area under the receiver operating characteristic curve, sensitivity, and specificity for a TBSS greater than 15 points was 0.985 (significantly higher than the other scoring systems evaluated at 0.892 and 0.813, respectively), 97.4%, and 96.2%, respectively. The TBSS is simple to calculate using an available iOS application and is accurate in predicting the need for massive transfusion. Additional multicenter studies are needed to further validate this scoring system and further assess its utility. Prognostic study, level III.
Djaladat, Hooman; Amini, Erfan; Xu, Weichen; Cai, Jie; Daneshmand, Siamak; Lieskovsky, Gary
2017-05-01
To assess the prognostic value of new Gleason grade grouping system in high-risk prostate cancer patients, we compared oncological outcomes after radical prostatectomy for patients with Gleason score 8 versus 9-10. Between 1987 and 2008, 3,755 men underwent radical prostatectomy with curative intent at University of Southern California. Patients who had Gleason score 8-10 at final histopathological evaluation (pT2-4N0) were included in this study. Eligible patients were divided into two groups; 226 with Gleason score 8 and 132 with Gleason score 9-10. Various patient and disease characteristics as well as oncological outcomes (biochemical recurrence, clinical recurrence, and overall survival) were compared between the groups. Impact of Gleason score on outcomes was controlled for preoperative prostate specific antigen, pathological stage, use of adjuvant radiotherapy, and neoadjuvant/adjuvant hormone therapy in multivariable analyses. A total of 358 patients (mean age: 65 years) were included in the analysis. Mean age and median duration of follow-up (9.6 years) were comparable between the study groups. Gleason 9-10 prostate cancer was associated with worse biochemical (HR 1.6; 95%CI [1.1-2.3]) and clinical recurrence free survival (HR = 1.9; 95%CI [1.1-3.3]); however, overall survival did not differ significantly between the groups. In addition, more patients with Gleason score 9-10 received adjuvant hormone therapy in the course of disease. Long-term follow-up after radical prostatectomy revealed significant differences in disease-specific outcomes between patients with Gleason score 8 versus 9-10. This sub-classification of high-risk patients might be helpful for patient counseling and determining therapeutic strategies. Prostate 77:743-748, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Engelken, Florian; Wassilew, Georgi I; Köhlitz, Torsten; Brockhaus, Sebastian; Hamm, Bernd; Perka, Carsten; Diederichs, und Gerd
2014-01-01
The purpose of this study was to quantify the performance of the Goutallier classification for assessing fatty degeneration of the gluteus muscles from magnetic resonance (MR) images and to compare its performance to a newly proposed system. Eighty-four hips with clinical signs of gluteal insufficiency and 50 hips from asymptomatic controls were analyzed using a standard classification system (Goutallier) and a new scoring system (Quartile). Interobserver reliability and intraobserver repeatability were determined, and accuracy was assessed by comparing readers' scores with quantitative estimates of the proportion of intramuscular fat based on MR signal intensities (gold standard). The existing Goutallier classification system and the new Quartile system performed equally well in assessing fatty degeneration of the gluteus muscles, both showing excellent levels of interrater and intrarater agreement. While the Goutallier classification system has the advantage of being widely known, the benefit of the Quartile system is that it is based on more clearly defined grades of fatty degeneration. Copyright © 2014 Elsevier Inc. All rights reserved.
Findings from the ISMP Medication Safety Self-Assessment for hospitals.
Smetzer, Judy L; Vaida, Allen J; Cohen, Michael R; Tranum, Diane; Pittman, Mary A; Armstrong, Carl W
2003-11-01
Hospital medication practices should be assessed, awareness of the characteristics of a safe medication system heightened, and baseline data to identify national priorities established. A cross-sectional survey of U.S. hospitals (N = 6,180) was conducted in May 2000. The survey instrument contained 194 self-assessment items organized into 20 core characteristics and 10 larger domains. Hospitals were asked to voluntarily submit their confidential assessment data to the Institute for Safe Medication Practices (ISMP) for aggregate analysis. A weighting structure was applied to the individual items and used to calculate core characteristic scores, domain scores, and overall self-assessment scores. These scores were then compared to identify areas most in need of improvement. The 1,435 participating hospitals scored highest in domains related to drug storage and distribution; environmental factors; infusion pumps; and medication labeling, packaging, and nomenclature issues. These hospitals scored lowest in domains related to accessible patient information, communication of medication orders, patient education, and quality processes such as double-check systems and organizational culture. Enormous opportunities exist to improve medication safety, especially in domains related to culture, information management, and communication.
Scoring systems of severity in patients with multiple trauma.
Rapsang, Amy Grace; Shyam, Devajit Chowlek
2015-04-01
Trauma is a major cause of morbidity and mortality; hence severity scales are important adjuncts to trauma care in order to characterize the nature and extent of injury. Trauma scoring models can assist with triage and help in evaluation and prediction of prognosis in order to organise and improve trauma systems. Given the wide variety of scoring instruments available to assess the injured patient, it is imperative that the choice of the severity score accurately match the application. Even though trauma scores are not the key elements of trauma treatment, they are however, an essential part of improvement in triage decisions and in identifying patients with unexpected outcomes. This article provides the reader with a compendium of trauma severity scales along with their predicted death rate calculation, which can be adopted in order to improve decision making, trauma care, research and in comparative analyses in quality assessment. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Measuring and explaining multi-directional inefficiency in the Malaysian dairy industry.
Mohd Suhaimi, Nurul Aisyah Binti; de Mey, Yann; Oude Lansink, Alfons
2017-01-01
The purpose of this paper is to measure the technical inefficiency of dairy farms and subsequently investigate the factors affecting technical inefficiency in the Malaysian dairy industry. This study uses multi-directional efficiency analysis to measure the technical inefficiency scores on a sample of 200 farm observations and single-bootstrap truncated regression model to define factors affecting technical inefficiency. Managerial and program inefficiency scores are presented for intensive and semi-intensive production systems. The results reveal marked differences in the inefficiency scores across inputs and between production systems. Intensive systems generally have lowest managerial and program inefficiency scores in the Malaysian dairy farming sector. Policy makers could use this information to advise dairy farmers to convert their farming system to the intensive system. The results suggest that the Malaysian Government should redefine its policy for providing farm finance and should target young farmers when designing training and extension programs in order to improve the performance of the dairy sector. The existing literature on Southeast Asian dairy farming has neither focused on investigating input-specific efficiency nor on comparing managerial and program efficiency. This paper aims to fill this gap.
Maempel, J F; Clement, N D; Brenkel, I J; Walmsley, P J
2015-04-01
This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p < 0.001) when using the sum of the AKS knee and function scores. Addition of body mass index and age (other statistically significant predictors of OKS) to the algorithm did not significantly increase the predictive value. The simple regression model was used to predict the OKS in a group of 236 patients who were clinically assessed nine to ten years after TKR using the AKS system. The predicted OKS was compared with actual OKS in the second group. Intra-class correlation demonstrated excellent reliability (r = 0.81, 95% confidence intervals 0.75 to 0.85) for the combined knee and function score when used to predict OKS. Our findings will facilitate comparison of outcome data from studies and registries using either the OKS or the AKS scores and may also be of value for those undertaking meta-analyses and systematic reviews. ©2015 The British Editorial Society of Bone & Joint Surgery.
Validation of the FAMACHA© system in South American camelids.
Storey, Bobby E; Williamson, Lisa H; Howell, Sue B; Terrill, Thomas H; Berghaus, Roy; Vidyashankar, Anand N; Kaplan, Ray M
2017-08-30
Haemonchus contortus resistant to multiple anthelmintics threaten the viability of the small ruminant industry in areas where this parasite is prevalent. In response to this situation, the FAMACHA© system was developed and validated for use with small ruminants as a way to detect clinical anemia associated with haemonchosis. Given that H. contortus and multiple anthelmintic resistance is a similar problem in camelids, the FAMACHA© system might also provide the same benefits. To address this need, a validation study of the FAMACHA© system was conducted on 21 alpaca and llama farms over a 2-year period. H. contortus was the predominant nematode parasite on 17 of the 21 farms (10 alpaca and 7 llama farms) enrolled in the study, based on fecal culture results. The FAMACHA© card was used to score the color of the lower palpebral (lower eye lid) conjunctiva on a 1-5 scale. Packed cell volume (PCV) values were measured and compared to FAMACHA© scores using FAMACHA© score cutoffs of ≥3 or ≥4 and with anemia defined as a PCV ≤15%, ≤17%, or≤20%. PCV was significantly associated with FAMACHA© score, fecal egg count (FEC), and body condition score (BCS), regardless of the FAMACHA© cutoff score or the PCV% chosen to define clinical anemia (p<0.01 in all cases). The use of FAMACHA© scores ≥3 and PCV ≥ 15% indicating anemia provided the best sensitivity (96.4% vs 92.9% for FAMACHA© ≥4), whereas FAMACHA scores ≥ 4 and PCV ≤20% provided the best specificity (94.2% vs 69.1% for FAMACHA© ≥3). The data from this study support the FAMACHA© system as a useful tool for detecting clinical anemia in camelids suffering from haemonchosis. Parameters for making treatment decisions based on FAMACHA© score in camelids should mirror those established for small ruminants. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Zhijian; Hou, Jiale; Lu, Lin; Tang, Shenglan; Ma, Jin
2012-01-01
Health care system reform is a major issue in many countries and therefore how to evaluate the effects of changes is incredibly important. This study measured residents' satisfaction with community health care service in Shanghai, China, and aimed to evaluate the effect of recent health care system reform. Face-to-face interviews were performed with a stratified random sample of 2212 residents of the Shanghai residents using structured questionnaires. In addition, 972 valid responses were retrieved from internet contact. Controlling for sex, age, income and education, the study used logistic regression modeling to analyze factors associated with satisfaction and to explain the factors that affect the residents' satisfaction. Comparing current attitudes with those held at the initial implementation of the reform in this investigation, four dimensions of health care were analyzed: 1) the health insurance system; 2) essential drugs; 3) basic clinical services; and 4) public health services. Satisfaction across all dimensions improved since the reform was initiated, but differences of satisfaction level were found among most dimensions and groups. Residents currently expressed greater satisfaction with clinical service (average score=3.79, with 5 being most satisfied) and the public health/preventive services (average score=3.62); but less satisfied with the provision of essential drugs (average score=3.20) and health insurance schemes (average score=3.23). The disadvantaged groups (the elderly, the retired, those with only an elementary education, those with lower incomes) had overall poorer satisfaction levels on these four aspects of health care (P<0.01). 25.39% of the respondents thought that their financial burden had increased and 38.49% thought that drugs had become more expensive. The respondents showed more satisfaction with the clinical services (average score=3.79) and public health services/interventions (average score=3.79); and less satisfaction with the health insurance system (average score=3.23) and the essential drug system (average score=3.20). Disadvantaged groups showed lower satisfaction levels overall relative to non-disadvantaged groups.
Yen, Jennifer; Van Arendonk, Kyle J.; Streiff, Michael B.; McNamara, LeAnn; Stewart, F. Dylan; Conner G, Kim G; Thompson, Richard E.; Haut, Elliott R.; Takemoto, Clifford M.
2017-01-01
OBJECTIVES Identify risk factors for venous thromboembolism (VTE) and develop a VTE risk assessment model for pediatric trauma patients. DESIGN, SETTING, AND PATIENTS We performed a retrospective review of patients 21 years and younger who were hospitalized following traumatic injuries at the John Hopkins level 1 adult and pediatric trauma center (1987-2011). The clinical characteristics of patients with and without VTE were compared, and multivariable logistic regression analysis was used to identify independent risk factors for VTE. Weighted risk assessment scoring systems were developed based on these and previously identified factors from patients in the National Trauma Data Bank (NTDB 2008-2010); the scoring systems were validated in this cohort from Johns Hopkins as well as a cohort of pediatric admissions from the NTDB (2011-2012). MAIN RESULTS Forty-nine of 17,366 pediatric trauma patients (0.28%) were diagnosed with VTE after admission to our trauma center. After adjusting for potential confounders, VTE was independently associated with older age, surgery, blood transfusion, higher Injury Severity Score (ISS), and lower Glasgow Coma Scale (GCS) score. These and additional factors were identified in 402,329 pediatric patients from the NTDB from 2008-2010; independent risk factors from the logistic regression analysis of this NTDB cohort were selected and incorporated into weighted risk assessment scoring systems. Two models were developed and were cross-validated in 2 separate pediatric trauma cohorts: 1) 282,535 patients in the NTDB from 2011 to 2012 2) 17,366 patients from Johns Hopkins. The receiver operator curve using these models in the validation cohorts had area under the curves that ranged 90% to 94%. CONCLUSIONS VTE is infrequent after trauma in pediatric patients. We developed weighted scoring systems to stratify pediatric trauma patients at risk for VTE. These systems may have potential to guide risk-appropriate VTE prophylaxis in children after trauma. PMID:26963757
Rimaitis, Kestutis; Marchertiene, Irena; Pavalkis, Dainius
2003-01-01
The purpose of our study is to compare two methods of postoperative analgesia in colorectal cancer patients after resectional operations, and to evaluate advantages and limitations of each method on the postoperative course of these patients. One hundred patients scheduled to undergo elective colorectal cancer surgery were randomized into two groups; after general anesthesia, one group received epidural analgesia (n=50) and the second one - intramuscular pethidine analgesia (n=50). Visual analogue scale at rest and on coughing was used to compare intensiveness of pain between the two groups during the day of surgery and first three postoperative days. Patients' mood and self-satisfaction were evaluated using self-assessment manikin scale. Side effects of both analgesia techniques were registered. All complications and postoperative hospital stay were also evaluated. Visual analogue scale pain scores at rest and on coughing were significantly better in epidural analgesia group as compared to systemic intramuscular pethidine analgesia group (p<0.05). Additional analgesics were needed for 10 (20%) and 28 (56%) patients respectively to keep visual analogue scale pain scores below 5. Adverse effects such as profound sedation, nausea and vomiting were more frequent in systemic intramuscular pethidine group, but pruritus - very uncommon to compare with epidural analgesia group (p<0.05). There were no significant differences between the two groups in respect to complications and postoperative hospital stay. Epidural analgesia has demonstrated significantly better effectiveness than intramuscular pethidine analgesia after colorectal cancer surgery with fewer adverse events. Self-assessment manikin scores showed better self-satisfaction in patients of epidural analgesia group as compared to patients in systemic pethidine group.
Yu, Yuncui; Jia, Lulu; Meng, Yao; Hu, Lihua; Liu, Yiwei; Nie, Xiaolu; Zhang, Meng; Zhang, Xuan; Han, Sheng; Peng, Xiaoxia; Wang, Xiaoling
2018-04-01
Establishing a comprehensive clinical evaluation system is critical in enacting national drug policy and promoting rational drug use. In China, the 'Clinical Comprehensive Evaluation System for Pediatric Drugs' (CCES-P) project, which aims to compare drugs based on clinical efficacy and cost effectiveness to help decision makers, was recently proposed; therefore, a systematic and objective method is required to guide the process. An evidence-based multi-criteria decision analysis model that involved an analytic hierarchy process (AHP) was developed, consisting of nine steps: (1) select the drugs to be reviewed; (2) establish the evaluation criterion system; (3) determine the criterion weight based on the AHP; (4) construct the evidence body for each drug under evaluation; (5) select comparative measures and calculate the original utility score; (6) place a common utility scale and calculate the standardized utility score; (7) calculate the comprehensive utility score; (8) rank the drugs; and (9) perform a sensitivity analysis. The model was applied to the evaluation of three different inhaled corticosteroids (ICSs) used for asthma management in children (a total of 16 drugs with different dosage forms and strengths or different manufacturers). By applying the drug analysis model, the 16 ICSs under review were successfully scored and evaluated. Budesonide suspension for inhalation (drug ID number: 7) ranked the highest, with comprehensive utility score of 80.23, followed by fluticasone propionate inhaled aerosol (drug ID number: 16), with a score of 79.59, and budesonide inhalation powder (drug ID number: 6), with a score of 78.98. In the sensitivity analysis, the ranking of the top five and lowest five drugs remains unchanged, suggesting this model is generally robust. An evidence-based drug evaluation model based on AHP was successfully developed. The model incorporates sufficient utility and flexibility for aiding the decision-making process, and can be a useful tool for the CCES-P.
Hammad, M; Eissa, M; Fathi, S
2016-08-01
Systemic lupus erythematosus (SLE) is a prototypic multisystem autoimmune disorder. The total damage in a patient with SLE may result from SLE itself or from any other pathologic process. The aim of this study was to assess risk factors of greater damage in a sample of Egyptian SLE patients. This Egyptian multicenter retrospective study included 100 SLE patients: 64 patients from Cairo University Hospitals and 36 patients from Zagazig University Hospitals. The Systemic Lupus International Collaborative Clinics (SLICC)/American College of Rheumatology (ACR) Damage Index (ACR-DI) was used to document the damage in each patient. The total SLICC/ACR-DI score ranged from 0 to 8. A higher DI score was found in hypertensive patients, compared to normotensive patients; and among those with positive anti-phospholipid antibodies, compared to those with negative anti-phospholipid antibodies. This difference was statistically significant (p < 0.01). Also, a higher DI score was found in cyclophosphamide users, compared to non-users; and in those with proteinuria and seizures, compared to those without; and the difference was statistically significant (p < 0.05). There was a significant positive correlation between the DI and patient age (p < 0.05). Damage in SLE cannot be prevented completely, as SLE disease is considered an aggressive disease treated by aggressive medications, but rheumatologists should try to minimize damage as much as possible to maintain the patients' health, functioning and general wellbeing. © The Author(s) 2016.
Everard, Eoin; Lyons, Mark; Harrison, Andrew J
2018-06-01
To examine the association of injury with the Functional Movement Screen (FMS) and Landing Error Scoring System (LESS) in military recruits undergoing an intensive 16-week training block. Prospective cohort study. One hundred and thirty-two entry-level male soldiers (18-25years) were tested using the FMS and LESS. The participants underwent an intensive 16-week training program with injury data recorded daily. Chi-squared statistics were used to examine associations between injury risk and (1) poor LESS scores, (2) any score of 1 on the FMS and (3) composite FMS score of ≤14. A composite FMS score of ≤14 was not a significant predictor of injury. LESS scores of >5 and having a score of 1 on any FMS test were significantly associated with injury. LESS scores had greater relative risk, sensitivity and specificity (2.2 (95% CI=1.48-3.34); 71% and 87% respectively) than scores of 1 on the FMS (relative risk=1.32 (95% CI=1.0-1.7); sensitivity=50% and specificity=76%). There was no association between composite FMS score and injury but LESS scores and scores of 1 in the FMS test were significantly associated with injury in varying degrees. LESS scores had a much better association with injury than both any scores of 1 on the FMS and a combination of LESS scores and scores of 1 on the FMS. Furthermore, the LESS provides comparable information related to injury risk as other well-established markers associated with injury such as age, muscular strength and previous injury. Copyright © 2017. Published by Elsevier Ltd.
Merk, Josef; Schlotz, Wolff; Falter, Thomas
2017-01-01
This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts. PMID:28979228
Merk, Josef; Schlotz, Wolff; Falter, Thomas
2017-01-01
This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts.
Suzuki, Takeshi; Yoshida, Ryochi; Okamoto, Akiko; Seri, Yu
2017-01-01
Objectives . To develop a scoring system for evaluating the extrasynovial soft tissue inflammation of the shoulders in patients with polymyalgia rheumatica (PMR) and elderly-onset rheumatoid arthritis with PMR-like onset (pm-EORA) using ultrasound. Methods . We analyzed stored power Doppler (PD) images obtained by the pretreatment examination of 15 PMR patients and 15 pm-EORA patients. A semiquantitative scoring system for evaluating the severity of PD signals adjacent to the anterior aspect of the subscapularis tendon was designed. Results . A four-point scale scoring for the hyperemia on the subscapularis tendon was proposed as follows in brief: 0 = absent or minimal flow, 1 = single vessel dots or short linear-shape signals, 2 = long linear-shape signals or short zone-shape signals, or 3 = long zone-shape signals. This scoring system showed good intra- and interobserver reliability and good correlation to quantitative pixel-counting evaluation. By using it, we demonstrated that inflammation in PMR is dominantly localized in extrasynovial soft tissue as compared with pm-EORA. Conclusions . We proposed a reliable semiquantitative scoring system using ultrasound for the evaluation of extrasynovial soft tissue inflammation of the shoulders in patients with both PMR and pm-EORA. This system is simple to use and can be utilized in future investigations.
French adaptation of the new Knee Society Scoring System for total knee arthroplasty.
Debette, C; Parratte, S; Maucort-Boulch, D; Blanc, G; Pauly, V; Lustig, S; Servien, E; Neyret, P; Argenson, J N
2014-09-01
In November 2011, the Knee Society published its new KSS score to evaluate objective clinical data and also patient expectations, satisfaction and knee function during various physical activities before and after total knee arthroplasty (TKA). We undertook the French cross-cultural adaptation of this scoring system according to current recommendations. The French version of the new KSS score is a consistent, feasible, reliable and discriminating score. Eighty patients with knee osteoarthritis were recruited from two centers: one group of 40 patients had a TKA indication, while the other group of 40 patients had an indication for conservative treatment. After the new KSS score was translated and back-translated, it was compared to three other validated instruments (KOOS, AMIQUAL and SF-12) to determine construct validity, discriminating power, feasibility in terms of response rate and existence of floor or ceiling effect, internal consistency with Chronbach's alpha and reliability based on reproducibility and sensitivity to change (responsiveness). Due to missing data, two cases were eliminated. We found that the score could discriminate between groups; it had a nearly 100% response rate, a ceiling effect in the "expectations" domain, satisfactory Chronbach's alpha, excellent reproducibility and good responsiveness. These results confirm that the French version of the new KSS score is reliable, feasible, discriminating, consistent and responsive. The novelty of this scoring system resides in the "expectations" and "satisfaction" domains, its availability as a self-assessment questionnaire and the evaluation of function during various activities. Level III. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Zhou, Lin; Guo, Jianming; Wang, Hang; Wang, Guomin
2015-01-01
Abstract In the zero ischemia era of nephron-sparing surgery (NSS), a new anatomic classification system (ACS) is needed to adjust to these new surgical techniques. We devised a novel and simple ACS, and compared it with the RENAL and PADUA scores to predict the risk of NSS outcomes. We retrospectively evaluated 789 patients who underwent NSS with available imaging between January 2007 and July 2014. Demographic and clinical data were assessed. The Zhongshan (ZS) score consisted of three parameters. RENAL, PADUA, and ZS scores are divided into three groups, that is, high, moderate, and low scores. For operative time (OT), significant differences were seen between any two groups of ZS score and PADUA score (all P < 0.05). For ZS score, patients with moderate and high scores had longer warm ischemia time (WIT) and greater increase in SCr compared with low score (all P < 0.05). What is more, the differences between moderate and high scores classified by ZS score were borderline but trending toward significance in WIT (P = 0.064) and increase in SCr (P = 0.052). Interestingly, RENAL showed no significant difference between moderate and high complexity in OT, WIT, estimated blood loss, and increase in SCr. Compared with patients with a low score of ZS, those with a high or moderate score had 8.1-fold or 3.3-fold higher risk of surgical complications, respectively (all P < 0.05). As for RENAL score, patients with a high or moderate score had 5.7-fold or 1.9-fold higher risk of surgical complications, respectively (all P < 0.05). Patients with a high or moderate score of PADUA had 2.3-fold or 2.8-fold higher risk of surgical complications, respectively (all P < 0.05). In the ROC curve analysis, ZS score had the greatest AUC for surgical complications (AUC = 0.632) and the conversion to radical nephrectomy (AUC = 0.845) (all P < 0.05). In conclusion, the ability of ZS score to predict the surgical complexity and surgical complications of NSS is better than RENAL and PADUA scores. ZS score could be used to reflect the surgical complexity and predict the risk of surgical complications in patients undergoing NSS. PMID:25654399
Lin, Wei-Ching; Muglia, Valdair F; Silva, Gyl E B; Chodraui Filho, Salomão; Reis, Rodolfo B; Westphalen, Antonio C
2016-06-01
To compare the diagnostic accuracies and interreader agreements of the Prostate Imaging Reporting and Data System (PI-RADS) v. 2 and University of California San Francisco (UCSF) multiparametric prostate MRI scale for diagnosing clinically significant prostate cancer. This institutional review board-approved retrospective study included 49 males who had 1.5 T endorectal MRI and prostatectomy. Two radiologists scored suspicious lesions on MRI using PI-RADS v. 2 and the UCSF scale. Percent agreement, 2 × 2 tables and the area under the receiver operating characteristic curves (Az) were used to assess and compare the individual and overall scores of these scales. Interreader agreements were estimated with kappa statistics. Reader 1 (R1) detected 78 lesions, and Reader 2 (R2) detected 80 lesions. Both identified 52 of 65 significant cancers. The Az for PI-RADS v. 2 and UCSF scale for R1 were 0.68 and 0.69 [T2 weighted imaging (T2WI)], 0.75 and 0.68 [diffusion-weighted imaging (DWI)] and 0.64 and 0.72 (overall score), respectively, and were 0.72 and 0.75 (T2WI), 0.73 and 0.67 (DWI) and 0.66 and 0.75 (overall score) for R2. The dynamic contrast-enhanced percent agreements between scales were 100% (R1) and 95% (R2). PI-RADS v. 2 DWI of R1 performed better than UCSF DWI (Az = 0.75 vs Az = 0.68; p = 0.05); no other differences were found. The interreader agreements were higher for PI-RADS v. 2 (T2WI: 0.56 vs 0.42; DWI: 0.60 vs 0.46; overall: 0.61 vs 0.42). The UCSF approach to derive the overall PI-RADS v. 2 scores increased the Az for the identification of significant cancer (R1 to 0.76, p < 0.05; R2 to 0.71, p = 0.35). Although PI-RADS v. 2 DWI score may have a higher discriminatory performance than the UCSF scale counterpart to diagnose clinically significant cancer, the utilization of the UCSF scale weighing system for the integration of PI-RADS v. 2 individual parameter scores improved the accuracy its overall score. PI-RADS v. 2 is moderately accurate for the identification of clinically significant prostate cancer, but the utilization of alternative approaches to derive the overall PI-RADS v. 2 score, including the one used by the UCSF system, may improve its diagnostic accuracy.
Sauerbruch, T; Ansari, H; Wotzka, R; Soehendra, N; Köpcke, W
1988-01-08
Prospective prognosis systems for predicting half-year death-rate after bleeding from oesophageal varices and sclerotherapy were tested on 129 patients. The receiver-operating-characteristic curves of three discriminant scores were compared with the Child-Pugh classification. It was found that the latter is still the best for prognosticating the course of the disease. A simplified discriminant score which contains as its only factors bilirubin and the Quick value does, however, give nearly as good information.
Chhor, Vibol; Merceron, Sybille; Ricome, Sylvie; Baron, Gabriel; Daoud, Omar; Dilly, Marie-Pierre; Aubier, Benjamin; Provenchere, Sophie; Philip, Ivan
2010-08-01
Although results of cardiac surgery are improving, octogenarians have a higher procedure-related mortality and more complications with increased length of stay in ICU. Consequently, careful evaluation of perioperative risk seems necessary. The aims of our study were to assess and compare the performances of EuroSCORE and CARE score in the prediction of perioperative mortality among octogenarians undergoing aortic valve replacement for aortic stenosis and to compare these predictive performances with those obtained in younger patients. This retrospective study included all consecutive patients undergoing cardiac surgery in our institution between November 2005 and December 2007. For each patient, risk assessment for mortality was performed using logistic EuroSCORE, additive EuroSCORE and CARE score. The main outcome measure was early postoperative mortality. Predictive performances of these scores were assessed by calibration and discrimination using goodness-of-fit test and area under the receiver operating characteristic curve, respectively. During this 2-year period, we studied 2117 patients, among whom 134/211 octogenarians and 335/1906 nonoctogenarians underwent an aortic valve replacement for aortic stenosis. When considering patients with aortic stenosis, discrimination was poor in octogenarians and the difference from nonoctogenarians was significant for each score (0.58, 0.59 and 0.56 vs. 0.82, 0.81 and 0.77 for additive EuroSCORE, logistic EuroSCORE and CARE score in octogenarians and nonoctogenarians, respectively, P < 0.05). Moreover, in the whole cohort, logistic EuroSCORE significantly overestimated mortality among octogenarians. Predictive performances of these scores are poor in octogenarians undergoing cardiac surgery, especially aortic valve replacement. Risk assessment and therapeutic decisions in octogenarians should not be made with these scoring systems alone.
2014-01-01
Background The aim of the study was to construct a new scoring system for more accurate diagnostics of acute appendicitis. Applying the new score into clinical practice could reduce the need of potentially harmful diagnostic imaging. Methods This prospective study enrolled 829 adults presenting with clinical suspicion of appendicitis, including 392 (47%) patients with appendicitis. The collected data included clinical findings and symptoms together with laboratory tests (white cell count, neutrophil count and C-reactive protein), and the timing of the onset of symptoms. The score was constructed by logistic regression analysis using multiple imputations for missing values. Performance of the constructed score in patients with complete data (n = 725) was compared with Alvarado score and Appendicitis inflammatory response score. Results 343 (47%) of patients with complete data had appendicitis. 199 (58%) patients with appendicitis had score value at least 16 and were classified as high probability group with 93% specificity.Patients with score below 11 were classified as low probability of appendicitis. Only 4% of patients with appendicitis had a score below 11, and none of them had complicated appendicitis. In contrast, 207 (54%) of non-appendicitis patients had score below 11. There were no cases with complicated appendicitis in the low probability group. The area under ROC curve was significantly larger with the new score 0.882 (95% CI 0.858 – 0.906) compared with AUC of Alvarado score 0.790 (0.758 – 0.823) and Appendicitis inflammatory response score 0.810 (0.779 – 0.840). Conclusions The new diagnostic score is fast and accurate in categorizing patients with suspected appendicitis, and roughly halves the need of diagnostic imaging. PMID:24970111
Comparing PETS and GEPT in China and Taiwan
ERIC Educational Resources Information Center
Wu, Mei
2012-01-01
This paper compares the Public English Test System (PETS) administered in mainland, China and the General English Proficiency Test (GEPT) administered in Taiwan, from the aspects of test levels, test contents and scoring weight. Compared with the PETS, the GEPT is found to value the English productive skills more, and have a greater ability to…
Cabin, William; Himmelstein, David U; Siman, Michael L; Woolhandler, Steffie
2014-08-01
For-profit, or proprietary, home health agencies were banned from Medicare until 1980 but now account for a majority of the agencies that provide such services. Medicare home health costs have grown rapidly since the implementation of a risk-based prospective payment system in 2000. We analyzed recent national cost and case-mix-adjusted quality outcomes to assess the performance of for-profit and nonprofit home health agencies. For-profit agencies scored slightly but significantly worse on overall quality indicators compared to nonprofits (77.18 percent and 78.71 percent, respectively). Notably, for-profit agencies scored lower than nonprofits on the clinically important outcome "avoidance of hospitalization" (71.64 percent versus 73.53 percent). Scores on quality measures were lowest in the South, where for-profits predominate. Compared to nonprofits, proprietary agencies also had higher costs per patient ($4,827 versus $4,075), were more profitable, and had higher administrative costs. Our findings raise concerns about whether for-profit agencies should continue to be eligible for Medicare payments and about the efficiency of Medicare's market-oriented, risk-based home care payment system. Project HOPE—The People-to-People Health Foundation, Inc.
Impact of a new simplified disability scoring system for adult patients with localized scleroderma.
Okiyama, Naoko; Asano, Yoshihide; Hamaguchi, Yasuhito; Jinnin, Masatoshi; Motegi, Sei-Ichiro; Koizumi, Haruka; Hasegawa, Minoru; Ishikawa, Osamu; Sato, Shinichi; Takehara, Kazuhiko; Yamamoto, Toshiyuki; Fujimoto, Manabu; Ihn, Hironobu
2018-04-01
Localized scleroderma (LoS) involves dermal but not internal inflammation and fibrosis. Cosmetic changes often impact quality of life (QOL), however, impairment of activities of daily living (ADL) in LoS patients has not been investigated. To determine what factor(s) are associated with ADL in adult patients with LoS, we performed a retrospective observational study in 177 Japanese adult LoS patients using a novel LoS disability score based on Barthel's indices of ADL: feeding, bathing, grooming, dressing, bowels, bladder, toilet use, transfers, mobility and stairs. LoS disability scores increased in proportion to the number of affected body parts but were not correlated to age and duration of illness. The presence of leg lesions significantly impaired ADL of LoS patients compared with lesions on other body parts. Patients treated with systemic medications, who tended to have multiple lesions, presented higher LoS disability scores than those without systemic treatments. Our study proposes that physicians evaluate ADL, not only QOL, in LoS patients. Our findings using LoS disability scoring indicate that multiple affected body parts and leg lesions are risk factors for ADL impairment. © 2018 Japanese Dermatological Association.
Gasco, Jaime; Braun, Jonathan D; McCutcheon, Ian E; Black, Peter M
2011-01-01
To objectively compare the complexity and diversity of the certification process in neurological surgery in member societies of the World Federation of Neurosurgical Societies. This study centers in continental Asia. We provide here an analysis based on the responses provided to a 13-item survey. The data received were analyzed, and three Regional Complexity Scores (RCS) were designed. To compare national board experience, eligibility requirements for access to the certification process, and the obligatory nature of the examinations, an RCS-Organizational score was created (20 points maximum). To analyze the complexity of the examination, an RCS-Components score was designed (20 points maximum). The sum of both is presented in a Global RCS score. Only those countries that responded to the survey and presented nationwide homogeneity in the conduction of neurosurgery examinations could be included within the scoring system. In addition, a descriptive summary of the certification process per responding society is also provided. On the basis of the data provided by our RCS system, the highest global RCS was achieved by South Korea and Malaysia (21/40 points) followed by the joint examination of Singapore and Hong-Kong (FRCS-Ed) (20/40 points), Japan (17/40 points), the Philippines (15/40 points), and Taiwan (13 points). The experience from these leading countries should be of value to all countries within Asia. Copyright © 2011 Elsevier Inc. All rights reserved.
Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun
2014-09-01
To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P<0.05). CACG group had greater total MD interocular asymmetry score compared with the NTG and POAG groups (among groups, P=0.008; NTG vs. CACG, P=0.005; POAG vs. CACG, P=0.009). CACG also presented with significantly higher local MD interocular asymmetry scores at central, inferior, and temporal areas compared with those of the POAG group and at inferior area compared with that of NTG group. No significant difference in either total or local MDs was detected between NTG and POAG (all P>0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.
Modifications of the National Early Warning Score for patients with chronic respiratory disease.
Pedersen, N E; Rasmussen, L S; Petersen, J A; Gerds, T A; Østergaard, D; Lippert, A
2018-02-01
The National Early Warning Score (NEWS) uses physiological variables to detect deterioration in hospitalized patients. However, patients with chronic respiratory disease may have abnormal variables not requiring interventions. We studied how the Capital Region of Denmark NEWS Override System (CROS), the Chronic Respiratory Early Warning Score (CREWS) and the Salford NEWS (S-NEWS) affected NEWS total scores and NEWS performance. In an observational study, we included patients with chronic respiratory disease. The frequency of use of CROS and the NEWS total score changes caused by CROS, CREWS and S-NEWS were described. NEWS, CROS, CREWS and S-NEWS were compared using 48-h mortality and intensive care unit (ICU) admission within 48 h as outcomes. We studied 11,266 patients during 25,978 admissions; the use of CROS lowered NEWS total scores in 40% of included patients. CROS, CREWS and S-NEWS had lower sensitivities than NEWS for 48-h mortality and ICU admission. Specificities and PPV were higher. CROS, CREWS and S-NEWS downgraded, respectively, 51.5%, 44.9% and 32.8% of the NEWS total scores from the 'mandatory doctor presence' and 'immediate doctor presence and specialist consultation' total score intervals to lower intervals. Capital Region of Denmark NEWS Override System was frequently used in patients with chronic respiratory disease. CROS, CREWS and S-NEWS reduced sensitivity for 48-h mortality and ICU admission. Using the methodology prevalent in the NEWS literature, we cannot conclude on the safety of these systems. Future prospective studies should investigate the balance between detection rate and alarm fatigue of different systems, or use controlled designs and patient-centred outcomes. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
How do Medical Societies Select Science for Conference Presentation? How Should They?
Kuczmarski, Thomas M.; Raja, Ali S.; Pallin, Daniel J.
2015-01-01
Introduction Nothing has been published to describe the practices of medical societies in choosing abstracts for presentations at their annual meetings. We surveyed medical societies to determine their practices, and also present a theoretical analysis of the topic. Methods We contacted a convenience sample of large U.S. medical conferences, and determined their approach to choosing abstracts. We obtained information from web sites, telephone, and email. Our theoretical analysis compares values-based and empirical approaches for scoring system development. Results We contacted 32 societies and obtained data on 28 (response rate 88%). We excluded one upon learning that research was not presented at its annual meeting, leaving 27 for analysis. Only 2 (7%) made their abstract scoring process available to submitters. Reviews were blinded in most societies (21;78%), and all but one asked reviewers to recuse themselves for conflict of interest (96%). All required ≥3 reviewers. Of the 24 providing information on how scores were generated, 21 (88%) reported using a single gestalt score, and three used a combined score created from pooled domain-specific sub-scores. We present a framework for societies to use in choosing abstracts, and demonstrate its application in the development of a new scoring system. Conclusions Most medical societies use subjective, gestalt methods to select research for presentation at their annual meetings and do not disclose to submitters the details of how abstracts are chosen. We present a new scoring system that is transparent to submitters and reviewers alike with an accompanying statement of values and ground rules. We discuss the challenges faced in selecting abstracts for a large scientific meeting and share the values and practical considerations that undergird the new system. PMID:26265966
How do Medical Societies Select Science for Conference Presentation? How Should They?
Kuczmarski, Thomas M; Raja, Ali S; Pallin, Daniel J
2015-07-01
Nothing has been published to describe the practices of medical societies in choosing abstracts for presentations at their annual meetings. We surveyed medical societies to determine their practices, and also present a theoretical analysis of the topic. We contacted a convenience sample of large U.S. medical conferences, and determined their approach to choosing abstracts. We obtained information from web sites, telephone, and email. Our theoretical analysis compares values-based and empirical approaches for scoring system development. We contacted 32 societies and obtained data on 28 (response rate 88%). We excluded one upon learning that research was not presented at its annual meeting, leaving 27 for analysis. Only 2 (7%) made their abstract scoring process available to submitters. Reviews were blinded in most societies (21;78%), and all but one asked reviewers to recuse themselves for conflict of interest (96%). All required ≥3 reviewers. Of the 24 providing information on how scores were generated, 21 (88%) reported using a single gestalt score, and three used a combined score created from pooled domain-specific sub-scores. We present a framework for societies to use in choosing abstracts, and demonstrate its application in the development of a new scoring system. Most medical societies use subjective, gestalt methods to select research for presentation at their annual meetings and do not disclose to submitters the details of how abstracts are chosen. We present a new scoring system that is transparent to submitters and reviewers alike with an accompanying statement of values and ground rules. We discuss the challenges faced in selecting abstracts for a large scientific meeting and share the values and practical considerations that undergird the new system.
Baker-Genaw, Kimberly; Kokas, Maria S; Ahsan, Syed F; Darnley-Fisch, Deborah; Drake, Sean; Goyal, Nikhil; Inamdar, Kedar; Moutzouros, Vasilios; Prabhakar, Deepak; Rolland, Laurie; Sangha, Roopina; Shreve, Maria; Woodward, Ann
2016-07-01
Little is known about residents' performance on the milestones at the institutional level. Our institution formed a work group to explore this using an institutional-level curriculum and residents' evaluation of the milestones. We assessed whether beginner-level milestones for interpersonal and communication skills (ICS) related to observable behaviors in ICS-focused objective structured clinical examinations (OSCEs) for postgraduate year (PGY) 1 residents across specialties. The work group compared ICS subcompetencies across 12 programs to identify common beginner-level physician-patient communication milestones. The selected ICS milestone sets were compared for common language with the ICS-OSCE assessment tool-the Kalamazoo Essential Elements of Communication Checklist-Adapted (KEECC-A). To assess whether OSCE scores related to ICS milestone scores, all PGY-1 residents from programs that were part of Next Accreditation System Phase 1 were identified; their OSCE scores from July 2013 to June 2014 and ICS subcompetency scores from December 2014 were compared. The milestones for 10 specialties and the transitional year had at least 1 ICS subcompetency that related to physician-patient communication. The language of the ICS beginner-level milestones appears similar to behaviors outlined in the KEECC-A. All 60 residents with complete data received at least a beginner-level ICS subcompetency score and at least a satisfactory score on all 3 OSCEs. The ICS-OSCE scores for PGY-1 residents appear to relate to beginner-level milestones for physician-patient communication across multiple specialties.
Segmental intelligibility of synthetic speech produced by rule.
Logan, J S; Greene, B G; Pisoni, D B
1989-08-01
This paper reports the results of an investigation that employed the modified rhyme test (MRT) to measure the segmental intelligibility of synthetic speech generated automatically by rule. Synthetic speech produced by ten text-to-speech systems was studied and compared to natural speech. A variation of the standard MRT was also used to study the effects of response set size on perceptual confusions. Results indicated that the segmental intelligibility scores formed a continuum. Several systems displayed very high levels of performance that were close to or equal to scores obtained with natural speech; other systems displayed substantially worse performance compared to natural speech. The overall performance of the best system, DECtalk--Paul, was equivalent to the data obtained with natural speech for consonants in syllable-initial position. The findings from this study are discussed in terms of the use of a set of standardized procedures for measuring intelligibility of synthetic speech under controlled laboratory conditions. Recent work investigating the perception of synthetic speech under more severe conditions in which greater demands are made on the listener's processing resources is also considered. The wide range of intelligibility scores obtained in the present study demonstrates important differences in perception and suggests that not all synthetic speech is perceptually equivalent to the listener.
Segmental intelligibility of synthetic speech produced by rule
Logan, John S.; Greene, Beth G.; Pisoni, David B.
2012-01-01
This paper reports the results of an investigation that employed the modified rhyme test (MRT) to measure the segmental intelligibility of synthetic speech generated automatically by rule. Synthetic speech produced by ten text-to-speech systems was studied and compared to natural speech. A variation of the standard MRT was also used to study the effects of response set size on perceptual confusions. Results indicated that the segmental intelligibility scores formed a continuum. Several systems displayed very high levels of performance that were close to or equal to scores obtained with natural speech; other systems displayed substantially worse performance compared to natural speech. The overall performance of the best system, DECtalk—Paul, was equivalent to the data obtained with natural speech for consonants in syllable-initial position. The findings from this study are discussed in terms of the use of a set of standardized procedures for measuring intelligibility of synthetic speech under controlled laboratory conditions. Recent work investigating the perception of synthetic speech under more severe conditions in which greater demands are made on the listener’s processing resources is also considered. The wide range of intelligibility scores obtained in the present study demonstrates important differences in perception and suggests that not all synthetic speech is perceptually equivalent to the listener. PMID:2527884
Promoting Systems Thinking through Biology Lessons
NASA Astrophysics Data System (ADS)
Riess, Werner; Mischo, Christoph
2010-04-01
This study's goal was to analyze various teaching approaches within the context of natural science lessons, especially in biology. The main focus of the paper lies on the effectiveness of different teaching methods in promoting systems thinking in the field of Education for Sustainable Development. The following methods were incorporated into the study: special lessons designed to promote systems thinking, a computer-simulated scenario on the topic "ecosystem forest," and a combination of both special lessons and the computer simulation. These groups were then compared to a control group. A questionnaire was used to assess systems thinking skills of 424 sixth-grade students of secondary schools in Germany. The assessment differentiated between a conceptual understanding (measured as achievement score) and a reflexive justification (measured as justification score) of systems thinking. The following control variables were used: logical thinking, grades in school, memory span, and motivational goal orientation. Based on the pretest-posttest control group design, only those students who received both special instruction and worked with the computer simulation showed a significant increase in their achievement scores. The justification score increased in the computer simulation condition as well as in the combination of computer simulation and lesson condition. The possibilities and limits of promoting various forms of systems thinking by using realistic computer simulations are discussed.
Terzi, Rabiye; Saruhan, Neslihan; Sağlam, A; Nar, Hatice; Kadioğlu, A
2009-12-01
We studied the changes in antioxidant system and chlorophyll fluorescence parameters in post-stress emerging Ctenanthe setosa (Rosc.) Eichler (Marantaceae) plants (PSE plants) having reduced leaf area under drought stress causing leaf rolling and re-watering. PSE plants were compared to primary stressed plants (PS) in previous studies. The parameters were measured at different visual leaf rolling scores from 1 to 4 (1 is unrolled, 4 is tightly rolled and the others is intermediate form). Water potentials and stomatal conductance of leaves were gradually decreased during leaf rolling. Similarly, maximum quantum efficiency of open PS II center and quantum yield of PS II decreased during the rolling period. Non-photochemical quenching of chlorophyll fluorescence decreased at score 2 then increased while photochemical quenching did not change during leaf rolling. Electron transport rate decreased only at score 4 but approximately reached to score 1 level after re-watering. Superoxide dismutase activity was not constant at all leaf rolling scores. Ascorbate peroxidase, catalase and glutathione reductase activities generally tended to increase during leaf rolling. Lipid peroxidation and H 2 O 2 content increased at score 2 but decreased at the later scores. On the other hand, O 2 .- production increased during the rolling period. After re-watering of the plants having score 4 of leaf rolling, antioxidant enzyme activities were lower than those of score 1. Other physiological parameters also tended to reach the value of score 1. The results indicated that PSE plants gained drought tolerance by reducing leaf area effectively induced their antioxidant systems and protected the photosynthesis under drought stress similar to PS plants.
Tian, Yaohua; Jian, Zhong; Xu, Beibei; Liu, Hui
2017-10-03
Comorbidities have considerable effects on survival outcomes. The primary objective of this retrospective study was to examine the association between age-adjusted Charlson comorbidity index (ACCI) score and postoperative in-hospital mortality in patients with digestive system cancer who have undergone surgical resection of their cancers. Using electronic hospitalization summary reports, we identified 315,464 patients who had undergone surgery for digestive system cancer in top-rank (Grade 3A) hospitals in China between 2013 and 2015. The Cox proportional hazard regression model was applied to evaluate the effect of ACCI score on postoperative mortality, with adjustments for sex, type of resection, anesthesia methods, and caseload of each healthcare institution. The postoperative in-hospital mortality rate in the study cohort was 1.2% (3,631/315,464). ACCI score had a positive graded association with the risk of postoperative in-hospital mortality for all cancer subtypes. The adjusted HRs for postoperative in-hospital mortality scores ≥ 6 for esophagus, stomach, colorectum, pancreas, and liver and gallbladder cancer were 2.05 (95% CI: 1.45-2.92), 2.00 (95% CI: 1.60-2.49), 2.54 (95% CI: 2.02-3.21), 2.58 (95% CI: 1.68-3.97), and 4.57 (95% CI: 3.37-6.20), respectively, compared to scores of 0-1. These findings suggested that a high ACCI score is an independent predictor of postoperative in-hospital mortality in Chinese patients with digestive system cancer who have undergone surgical resection.
Automated Assessment of Postural Stability (AAPS)
2016-10-01
with human volunteers and used our preliminary data to quantify system calibration and limitations of performance. We have also compared our system’s...scoring. Furthermore, we have begun the process of testing with human volunteers and used our preliminary data to quantify system calibration and
Cosín Aguilar, J; Hernándiz Martínez, A; Rodríguez Padial, L; Zamorano Gómez, J L; Arístegui Urrestarazu, R; Armada Peláez, B; Aguilar Llopis, A; Masramon Morell, X
2006-04-01
Calculation of cardiovascular risk in populations allows for developing and assessing of intervention programs and adapting health resources. While the Framingham System has been used in the past, a group of European researchers have proposed a different method called the Score project. The purpose of this paper is to compare the value of both methods for assessing cardiovascular risk. In 6,775 evaluable hypertensive patients distributed over the 17 Spanish autonomous communities (ACs), the 10-year risk of experiencing a coronary event (CR) was calculated using the Framingham equation, while risk of coronary death (RCD) and vascular death (RVD) was calculated using the Score project system, both at baseline and after one year of blood pressure control with amlodipine at the required dose. A comparison was made of the capacity to detect risk differences by both methods between populations with known different risks, and in the same population as a result of blood pressure control. Both the Score and the Framingham systems detected the significant decrease in both CR and RCD or RVD at one year of application of the CORONARIA study protocol. Risk decrease measured by any of the two methods was significant (p < 0.05) overall, by genders, and by ACs. However, the Score System, unlike the Framingham system, could not detect the reported differences in the mortality risk for coronary and vascular disease between the ACs of the North and the South-East parts of Spain.
Dobson, Ruth; Leddy, Sara Geraldine; Gangadharan, Sunay; Giovannoni, Gavin
2013-01-01
Objectives Suboptimal bone health is increasingly recognised as an important cause of morbidity. Multiple sclerosis (MS) has been consistently associated with an increased risk of osteoporosis and fracture. Various fracture risk screening tools have been developed, two of which are in routine use and a further one is MS-specific. We set out to compare the results obtained by these in the MS clinic population. Design This was a service development study. The 10-year risk estimates of any fracture and hip fracture generated by each of the algorithms were compared. Setting The MS clinic at the Royal London Hospital. Participants 88 patients with a confirmed diagnosis of MS. Outcome measures Mean 10-year overall fracture risk and hip fracture risk were calculated using each of the three fracture risk calculators. The number of interventions that would be required as a result of using each of these tools was also compared. Results Mean 10-year fracture risk was 4.7%, 2.3% and 7.6% using FRAX, QFracture and the MS-specific calculator, respectively (p<0.0001 for difference). The agreement between risk scoring tools was poor at all levels of fracture risk. Conclusions The agreement between these three fracture risk scoring tools is poor in the MS population. Further work is required to develop and validate an accurate fracture risk scoring system for use in MS. Trial registration This service development study was approved by the Clinical Effectiveness Department at Barts Health NHS Trust (project registration number 156/12). PMID:23482989
Dyspnea in Chronic Fatigue Syndrome (CFS): Comparison of Two Prospective Cross-Sectional Studies
Ravindran, Murugan K.; Adewuyi, Oluwatoyin; Zheng, Yin; Rayhan, Rakib U.; Le, Uyenphuong; Timbol, Christian R.; Merck, Samantha; Esteitie, Rania; Cooney, Michelle; Read, Charles; Baraniuk, James N.
2013-01-01
Chronic Fatigue Syndrome (CFS) subjects have many systemic complaints including shortness of breath. Dyspnea was compared in two CFS and control cohorts to characterize pathophysiology. Cohort 1 of 257 CFS and 456 control subjects were compared using the Medical Research Council chronic Dyspnea Scale (MRC Score; range 0-5). Cohort 2 of 106 CFS and 90 controls answered a Dyspnea Severity Score (range 0-20) adapted from the MRC Score. Subsets of both cohorts completed CFS Severity Scores, fatigue, and other questionnaires. A subset had pulmonary function and total lung capacity measurements. Results show MRC Scores were equivalent between sexes in Cohort 1 CFS (1.92 [1.72-2.16]; mean [95% C.I.]) and controls (0.31 [0.23-0.39]; p<0.0001). Receiver-operator curves identified 2 as the threshold for positive MRC Scores in Cohort 1. This indicated 54% of CFS, but only 3% of controls, had significant dyspnea. In Cohort 2, Dyspnea Score threshold of 4 indicated shortness of breath in 67% of CFS and 23% of controls. Cohort 2 Dyspnea Scores were higher for CFS (7.80 [6.60-9.00]) than controls (2.40 [1.60-3.20]; p<0.0001). CFS had significantly worse fatigue and other complaints compared to controls. Pulmonary function was normal in CFS, but Borg scores and sensations of chest pain and dizziness were significantly greater during testing than controls. General linear model of Cohort 2 CFS responses linked Dyspnea with rapid heart rate, chest pain and dizziness. In conclusion, sensory hypersensitivity without airflow limitation contributed to dyspnea in CFS. Correlates of dyspnea in controls were distinct from CFS suggesting different mechanisms. PMID:23445698
Dyspnea in Chronic Fatigue Syndrome (CFS): comparison of two prospective cross-sectional studies.
Ravindran, Murugan; Adewuyi, Oluwatoyin; Zheng, Yin; Rayhan, Rakib U; Le, Uyenphuong; Timbol, Christian; Merck, Samantha; Esteitie, Rania; Read, Charles; Cooney, Michelle; Baraniuk, James
2012-12-12
Chronic Fatigue Syndrome (CFS) subjects have many systemic complaints including shortness of breath. Dyspnea was compared in two CFS and control cohorts to characterize pathophysiology. Cohort 1 of 257 CFS and 456 control subjects were compared using the Medical Research Council chronic Dyspnea Scale (MRC Score; range 0-5). Cohort 2 of 106 CFS and 90 controls answered a Dyspnea Severity Score (range 0-20) adapted from the MRC Score. Subsets of both cohorts completed CFS Severity Scores, fatigue, and other questionnaires. A subset had pulmonary function and total lung capacity measurements. Results show MRC Scores were equivalent between sexes in Cohort 1 CFS (1.92 [1.72-2.16]; mean [95% C.I.]) and controls (0.31 [0.23-0.39]; p<0.0001). Receiver-operator curves identified 2 as the threshold for positive MRC Scores in Cohort 1. This indicated 54% of CFS, but only 3% of controls, had significant dyspnea. In Cohort 2, Dyspnea Score threshold of 4 indicated shortness of breath in 67% of CFS and 23% of controls. Cohort 2 Dyspnea Scores were higher for CFS (7.80 [6.60-9.00]) than controls (2.40 [1.60-3.20]; p<0.0001). CFS had significantly worse fatigue and other complaints compared to controls. Pulmonary function was normal in CFS, but Borg scores and sensations of chest pain and dizziness were significantly greater during testing than controls. General linear model of Cohort 2 CFS responses linked Dyspnea with rapid heart rate, chest pain and dizziness. In conclusion, sensory hypersensitivity without airflow limitation contributed to dyspnea in CFS. Correlates of dyspnea in controls were distinct from CFS suggesting different mechanisms.
Trammell, Terry R; Flint, Kathy; Ramsey, Curtis J
2012-08-15
Magnetic resonance imaging (MRI) and computed tomography (CT) imaging are important postoperative diagnostic and evaluation tools, particularly in patients who have undergone spinal fusions. Advancements in materials and imaging techniques have lessened artifact and improved overall imaging results. Systems that combine titanium alloy and cobalt-chromium components have been introduced to reduce implant profile while maintaining strength. The objective of this study was to determine if there were any differences in the clarity of imaging between two types of implant materials in a lumbar spine construct model. One of two lumbar spine stabilization implant systems, titanium alloy (titanium) or titanium alloy with cobalt-chromium alloy (titanium-cobalt), was placed to simulate a four-level fusion construct in two human cadaveric spine segments, followed by MRI and CT imaging. The implant systems were then removed from each cadaver and implanted in the other cadaver. Nine physician graders from three subspecialties scored the images using a 5-point scale, with higher imaging scores indicating greater clarity of the region of interest. Physician-rated scores were compared across systems and between physician groups. There were no significant differences in the overall mean total scores on the basis of construct material. Overall mean scores were 18.16 for titanium and 17.45 for titanium-cobalt (p = 0.275). Among images of the titanium-cobalt constructs, no significant differences in mean scores were found between specimens with use of MRI (p = 0.883) or with use of CT only (p = 0.274). Among images of the titanium system, a slightly significant difference was found between specimens with use of MRI (p = 0.044) but not with CT imaging (p = 0.837). Overall image clarity scores were not significantly different between titanium and titanium-cobalt implant systems in the lumbar spine. Observation of pertinent anatomy in the regions of interest was not degraded by the presence of either system.
Aiding alternatives assessment with an uncertainty-tolerant hazard scoring method.
Faludi, Jeremy; Hoang, Tina; Gorman, Patrick; Mulvihill, Martin
2016-11-01
This research developed a single-score system to simplify and clarify decision-making in chemical alternatives assessment, accounting for uncertainty. Today, assessing alternatives to hazardous constituent chemicals is a difficult task-rather than comparing alternatives by a single definitive score, many independent toxicological variables must be considered at once, and data gaps are rampant. Thus, most hazard assessments are only comprehensible to toxicologists, but business leaders and politicians need simple scores to make decisions. In addition, they must balance hazard against other considerations, such as product functionality, and they must be aware of the high degrees of uncertainty in chemical hazard data. This research proposes a transparent, reproducible method to translate eighteen hazard endpoints into a simple numeric score with quantified uncertainty, alongside a similar product functionality score, to aid decisions between alternative products. The scoring method uses Clean Production Action's GreenScreen as a guide, but with a different method of score aggregation. It provides finer differentiation between scores than GreenScreen's four-point scale, and it displays uncertainty quantitatively in the final score. Displaying uncertainty also illustrates which alternatives are early in product development versus well-defined commercial products. This paper tested the proposed assessment method through a case study in the building industry, assessing alternatives to spray polyurethane foam insulation containing methylene diphenyl diisocyanate (MDI). The new hazard scoring method successfully identified trade-offs between different alternatives, showing finer resolution than GreenScreen Benchmarking. Sensitivity analysis showed that different weighting schemes in hazard scores had almost no effect on alternatives ranking, compared to uncertainty from data gaps. Copyright © 2016 Elsevier Ltd. All rights reserved.
Machhindra, Morey Vivek; Kang, Jong Yeal; Kang, Yeon Gwi; Chowdhry, Madhav; Kim, Tae Kyun
2015-12-01
We determined whether a new mobile-bearing ultra-congruent (UC) TKA system provides better functional outcomes than an established posterior-stabilized (PS) prosthesis. The functional outcomes (motion arc, AKS scores, WOMAC Index, and SForm-36 scores evaluated at 1 and 2 years postoperatively), satisfaction and incidences of adverse events were compared between the knees implanted with mobile-bearing UC prosthesis (n=103) and the mobile-bearing PS prosthesis (n=99). At 2 years, mobile-bearing UC TKAs showed similar functional outcomes and satisfaction, but smaller motion arc compared to mobile-bearing PS TKAs (126° vs. 131°). There were no differences in the incidence of adverse events. Mobile-bearing UC prosthesis can be considered a safe and viable alternative to the PS design, with an expectation of smaller postoperative maximum flexion. Copyright © 2015 Elsevier Inc. All rights reserved.
A gallery approach for off-angle iris recognition
NASA Astrophysics Data System (ADS)
Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher
2015-05-01
It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.
A comparison of scoring weights for the EuroQol derived from patients and the general public.
Polsky, D; Willke, R J; Scott, K; Schulman, K A; Glick, H A
2001-01-01
General health state classification systems, such as the EuroQol instrument, have been developed to improve the systematic measurement and comparability of health state preferences. In this paper we generate valuations for EuroQol health states using responses to this instrument's visual analogue scale made by patients enrolled in a randomized clinical trial evaluating tirilazad mesylate, a new drug used to treat subarachnoid haemorrhage. We then compare these valuations derived from patients with published valuations derived from responses made by a sample from the general public. The data were derived from two sources: (1) responses to the EuroQol instrument from 649 patients 3 months after enrollment in the clinical trial, and (2) from a published study reporting a scoring rule for the EuroQol instrument that was based upon responses made by the general public. We used a linear regression model to develop an additive scoring rule. This rule enables direct valuation of all 243 EuroQol health states using patients' scores for their own health states elicited using a visual analogue scale. We then compared predicted scores generated using our scoring rule with predicted scores derived from a sample from the general public. The predicted scores derived using the additive scoring rules met convergent validity criteria and explained a substantial amount of the variation in visual analogue scale scores (R(2)=0.57). In the pairwise comparison of the predicted scores derived from the study sample with those derived from the general public, we found that the former set of scores were higher for 223 of the 243 states. Despite the low level of correspondence in the pairwise comparison, the overall correlation between the two sets of scores was 87%. The model presented in this paper demonstrated that scoring weights for the EuroQol instrument can be derived directly from patient responses from a clinical trial and that these weights can explain a substantial amount of variation in health valuations. Scoring weights based on patient responses are significantly higher than those derived from the general public. Further research is required to understand the source of these differences. Copyright 2001 John Wiley & Sons, Ltd.
Time Burden of Standardized Hip Questionnaires.
Chughtai, Morad; Khlopas, Anton; Mistry, Jaydev B; Gwam, Chukwuweike U; Elmallah, Randa K; Mont, Michael A
2016-04-01
Many standardized scales and questionnaires have been developed to assess outcomes of patients undergoing total hip arthroplasty (THA). However, these surveys can be a burden to both patients and orthopaedists as some are time-inefficient. In addition, there is a paucity of reports assessing the time it takes to complete them. In this study we aimed to: (1) assess how long it takes to complete the most common standardized hip questionnaires; (2) determine the presence of variation in completion time; and (3) evaluate the effects of age, gender, and level of education on completion time. Based on a previous study, we selected the seven most commonly used hip scoring systems-Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), Larson Score, Short-form 36 (SF-36), modified Merle d'Aubigne and Postel Score (MDA), and Lower Extremity Functional Scale (LEFS). The standardized scales and questionnaires were randomly administered to 70 subjects. The subjects were unaware that they were being timed during completion of the questionnaire. We obtained the coefficients of variation of time for each questionnaire. The mean time to complete the questionnaire was then stratified and compared based on age, gender, and level of education. The mean time to complete each of the systems is listed in ascending order: Modified Merle d'Aubigne and Postel Score (MDA), Lower Extremity Functional Scale (LEFS), Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Larson Score, Hip Disability and Osteoarthritis Outcome Score (HOOS), and Short-form 36 (SF-36). The WOMAC and Larson Score coefficients of variation were the largest, and the HOOS and MDA were the smallest. There was a significantly higher mean time to completion in those who were above or equal to the age of 55 years as compared to those who were below the age of 55 (227 vs. 166 seconds). There was no significant association found in time of completion between gender or education level. Standardized scales and questionnaire which assess THA patients can be burdensome and time-inefficient, which may lead to task-induced fatigue. This may result in inaccurate THA patient assessments, which do not reflect the patient's true state. Future studies should aim to create an encompassing questionnaire that is time efficient and can replace all currently used validated systems.
Investigating histological aspects of scars in children.
Westra, I; Verhaegen, P D H M; Ibrahim Korkmaz, H; Braam, K I; Kaspers, G J L; Niessen, H W M; Niessen, F B
2017-05-02
Very little is known about histological aspects of paediatric scars and the possible role of the immune system during their formation. In this study, the histology thoracic scars caused by the placement of an implantable central venous access device in children who underwent treatment for cancer was assessed. The amount and type of collagen, the collagen orientation, the type of elastic fibres, the vascularsation, and the count of neutrophils, macrophages, and lymphocytes were analysed. The severity of scarring was assessed using the Vancouver scar scale (VSS). To evaluate the role of the immune system on scar severity and histology, the scars of children suffering from acute lymphoblastic leukaemia (ALL) were compared with the scars of children suffering from other types of childhood cancer. Our results showed an extremely random orientation of the collagen fibres of the paediatric scars with a mean collagen orientation index of 0.22 (standard deviation (SD) 0.10, zero indicating a perfectly random orientation and a perfectly parallel orientation). A lower collagen orientation index was seen in scars with a lower VSS score (VSS score <3: 0.19 versus VSS score ≥3 0.29, p=0.037). A higher total VSS score, resembling a worse scar, was assessed to the scars in the non-ALL group compared with the children with ALL (mean ALL: 0.91 (0-3) versus mean non-ALL: 2.50 (0-6), p=0.037). To our knowledge, this is the first study investigating a wide array of histological aspects in paediatric scars. Compared with adult scars, an extremely random collagen orientation was found (0.22 in children versus 0.41 and 0.46 adult normotrophic and hypertrophic scars, respectively). A lower collagen orientation index was found in scars with a lower VSS score. In addition, less severe scarring was measured in children suffering from ALL compared with children suffering from other types of childhood cancer. This suggests that the immune system could play a role in the development of aberrant scarring and should be a target for future research.
Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G
2015-06-01
To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of vascular indices or endometrial volume. The optimal imaging modality appears to be real-time 2D-GIS. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Consumer perceptions of the Nutrition Facts table and front-of-pack nutrition rating systems.
Emrich, Teri E; Qi, Ying; Mendoza, Julio E; Lou, Wendy; Cohen, Joanna E; L'abbé, Mary R
2014-04-01
Preferences for, and consumer friendliness of, front-of-pack (FOP) nutrition rating systems have not been studied in a Canadian population, and studies comparing systems that are accompanied by mandatory labelling, such as Canada's Nutrition Facts table (NFt), are lacking. The purpose of this study was to evaluate 4 FOP systems relative to the NFt with respect to consumer friendliness and their influence on perceptions of the healthiness and nutrient content of food. Canadian consumers (n = 3029) participating in an online survey were randomized to score the consumer friendliness of 1 of 5 FOP conditions with or without an NFt and to score the healthiness and nutrient content of 2 foods using the provided label(s). The mean differences in scores were evaluated with analysis of covariance (ANCOVA) controlling for age, gender, and education, with Tukey-Kramer adjustments for multiple comparisons. The NFt received the highest scores of consumer friendliness with respect to liking, helpfulness, credibility, and influence on purchase decisions (p < 0.05); however, consumers still supported the implementation of a single, standardized FOP system, with the nutrient-specific systems (a "Traffic Light" and a Nutrition Facts FOP system) being preferred and scored as more consumer friendly than the summary indicator systems. Without the NFt, consumer ratings of the healthiness and calorie and nutrient content differed by FOP system. With the NFt present, consumers rated the healthiness and calorie and nutrient content similarly, except for those who saw the Traffic Light; their ratings were influenced by the Traffic Light's colours. The introduction of a single, standard, nutrient-specific FOP system to supplement the mandatory NFt should be considered by Canadian policy makers.
Koh, Mark Jean-Ann; Giam, Yoke Chin; Liew, Hui Min; Foong, Alice Yee-Wah; Chong, Jin Ho; Wong, Sharon Mun Yee; Tang, Mark Boon Yang; Ho, Madeline Sheun Ling; Tan, Lucinda Siyun; Mason, James M; Cork, Michael J
2017-09-01
Patient eczema severity time (PEST) is a new atopic dermatitis (AD) scoring system based on patients' own perception of their disease. Conventional scales such as SCORing of atopic dermatitis (SCORAD) reflect the clinician's observations during the clinic visit. Instead, the PEST score captures eczema severity, relapse and recovery as experienced by the patient or caregiver on a daily basis, promoting patient engagement, compliance with treatment and improved outcomes. This study aims to determine the correlation between carer-assessed PEST and clinician-assessed SCORAD in paediatric AD patients after 12 weeks of treatment using a ceramide-dominant therapeutic moisturizer. Prospective, open-label, observational, multi-centre study in which children with AD aged 6 months to 6 years were treated with a ceramide dominant therapeutic moisturizer twice daily for 12 weeks; 58 children with mild-to-moderate AD were included. Correlation between the 7-day averaged PEST and SCORAD scores for assessment of AD severity was measured within a general linear model. PEST and SCORAD were compared in week 4 and week 12. At week 12, a moderate correlation was found between the SCORAD and PEST scores (r = 0.51). The mean change in SCORAD and PEST scores from baseline to week 12 was -11.46 [95% confidence interval (CI) -14.99 to -7.92, p < 0.0001] and -1.33 (95% CI -0.71 to -0.10, p < 0.0001) respectively. PEST demonstrated greater responsiveness to change (33.3% of scale) compared to SCORAD (13.8% of scale). The PEST score correlates well with the SCORAD score and may have improved sensitivity when detecting changes in the severity of AD. The ceramide-dominant therapeutic moisturizer used was safe and effective in the management of AD in young children. Hyphens Pharma Pte Ltd. clinicaltrials.gov identifier, NCT02073591.
Real-Time Risk Prediction on the Wards: A Feasibility Study.
Kang, Michael A; Churpek, Matthew M; Zadravecz, Frank J; Adhikari, Richa; Twu, Nicole M; Edelson, Dana P
2016-08-01
Failure to detect clinical deterioration in the hospital is common and associated with poor patient outcomes and increased healthcare costs. Our objective was to evaluate the feasibility and accuracy of real-time risk stratification using the electronic Cardiac Arrest Risk Triage score, an electronic health record-based early warning score. We conducted a prospective black-box validation study. Data were transmitted via HL7 feed in real time to an integration engine and database server wherein the scores were calculated and stored without visualization for clinical providers. The high-risk threshold was set a priori. Timing and sensitivity of electronic Cardiac Arrest Risk Triage score activation were compared with standard-of-care Rapid Response Team activation for patients who experienced a ward cardiac arrest or ICU transfer. Three general care wards at an academic medical center. A total of 3,889 adult inpatients. The system generated 5,925 segments during 5,751 admissions. The area under the receiver operating characteristic curve for electronic Cardiac Arrest Risk Triage score was 0.88 for cardiac arrest and 0.80 for ICU transfer, consistent with previously published derivation results. During the study period, eight of 10 patients with a cardiac arrest had high-risk electronic Cardiac Arrest Risk Triage scores, whereas the Rapid Response Team was activated on two of these patients (p < 0.05). Furthermore, electronic Cardiac Arrest Risk Triage score identified 52% (n = 201) of the ICU transfers compared with 34% (n = 129) by the current system (p < 0.001). Patients met the high-risk electronic Cardiac Arrest Risk Triage score threshold a median of 30 hours prior to cardiac arrest or ICU transfer versus 1.7 hours for standard Rapid Response Team activation. Electronic Cardiac Arrest Risk Triage score identified significantly more cardiac arrests and ICU transfers than standard Rapid Response Team activation and did so many hours in advance.
Salamat, Sara; Hutchings, John; Kwong, Clemens; Magnussen, John; Hancock, Mark J
2016-01-01
To assess the relationship between quantitative measures of disc height and signal intensity with the Pfirrmann disc degeneration scoring system and to test the inter-rater reliability of the quantitative measures. Participants were 76 people who had recently recovered from their last episode of acute low back pain and underwent MRI scan on a single 3T machine. At all 380 lumbar discs, quantitative measures of disc height and signal intensity were made by 2 independent raters and compared to Pfirrmann scores from a single radiologist. For quantitative measures of disc height and signal intensity a "raw" score and 2 adjusted ratios were calculated and the relationship with Pfirrmann scores was assessed. The inter-tester reliability of quantitative measures was also investigated. There was a strong linear relationship between quantitative disc signal intensity and Pfirrmann scores for grades 1-4, but not for grades 4 and 5. For disc height only, Pfirrmann grade 5 had significantly reduced disc height compared to all other grades. Results were similar regardless of whether raw or adjusted scores were used. Inter-rater reliability for the quantitative measures was excellent (ICC > 0.97). Quantitative measures of disc signal intensity were strongly related to Pfirrmann scores from grade 1 to 4; however disc height only differentiated between grade 4 and 5 Pfirrmann scores. Using adjusted ratios for quantitative measures of disc height or signal intensity did not significantly alter the relationship with Pfirrmann scores.
Stapler Esophageal Closure During Total Laryngectomy.
Ismi, Onur; Unal, Murat; Vayisoglu, Yusuf; Yesilova, Mesut; Helvaci, Ilter; Gorur, Kemal; Ozcan, Cengiz
2017-01-01
Mechanical esophageal closure with stapler during total laryngectomy has been used by various authors to decrease the surgical time and pharyngocutaneous fistula (PCF) rates. In a few of the studies, surgical site infection (SSI) rates are mentioned and none of the studies emphasize the effect of decreased surgical time on postoperative cardiovascular and cerebrovascular complications. In this study, the authors compared the PCF rates, SSI rates, operation times between 30 mechanical stapler and 40 manual esophageal closure during total laryngectomy for laryngeal cancer patients. National Nasocomial Infections Surveillance system (NNISS) scores were recorded and compared between groups. Total laryngectomy and total operation times were lower in the stapler group patients (P < 0.001 for total laryngectomy time, P = 0.024 for total operation time). There were lower rates of pharyngocutaneous fistula (P = 0.032), surgical site infection (P = 0.019), and NNISS scores (P = 0.009) in the stapler group. There was no statistically significant difference between groups regarding postoperative systemic complications (P = 0.451). In conclusion, stapler esophageal closure decreases operation time, PCF, SSI rates, and NNISS scores but not the systemic complication rates. Comorbid illnesses and prolonged surgical time are risk factors for postoperative systemic complications in total laryngectomy patients, but patients with additional illnesses must not encourage the surgeon to use stapler for decreasing postoperative systemic complications.
Kopec, Jacek A; Sayre, Eric C; Rogers, Pamela; Davis, Aileen M; Badley, Elizabeth M; Anis, Aslam H; Abrahamowicz, Michal; Russell, Lara; Rahman, Md Mushfiqur; Esdaile, John M
2015-10-01
The CAT-5D-QOL is a previously reported item response theory (IRT)-based computerized adaptive tool to measure five domains (attributes) of health-related quality of life. The objective of this study was to develop and validate a multiattribute health utility (MAHU) scoring method for this instrument. The MAHU scoring system was developed in two stages. In phase I, we obtained standard gamble (SG) utilities for 75 hypothetical health states in which only one domain varied (15 states per domain). In phase II, we obtained SG utilities for 256 multiattribute states. We fit a multiplicative regression model to predict SG utilities from the five IRT domain scores. The prediction model was constrained using data from phase I. We validated MAHU scores by comparing them with the Health Utilities Index Mark 3 (HUI3) and directly measured utilities and by assessing between-group discrimination. MAHU scores have a theoretical range from -0.842 to 1. In the validation study, the scores were, on average, higher than HUI3 utilities and lower than directly measured SG utilities. MAHU scores correlated strongly with the HUI3 (Spearman ρ = 0.78) and discriminated well between groups expected to differ in health status. Results reported here provide initial evidence supporting the validity of the MAHU scoring system for the CAT-5D-QOL. Copyright © 2015 Elsevier Inc. All rights reserved.
Ng, Alex L K; Choy, Bonnie N K; Chan, Tommy C Y; Wong, Ian Y H; Lai, Jimmy S M; Mok, Mo Yin
2017-07-01
To compare tear osmolarity (TO) and other dry eye parameters in rheumatoid arthritis (RA) patients with or without secondary Sjogren syndrome (sSS). Consecutive patients with RA were divided into a sSS group and no-sSS group using conventional diagnostic criteria by rheumatologists using symptomatology, Schirmer test score, and anti-Ro or anti-La autoantibody status. The TO, Ocular Surface Disease Index, dry eye disease (DED) parameters [such as tear breakup time (TBUT) and corneal staining score] and the systemic inflammatory markers [erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP)] were compared. Correlation analyses between TO and the DED parameters and inflammatory markers were also performed. A total of 42 cases with mean age 54.8 ± 12.3 were included, with 12 patients (29%) having sSS and 30 (71%) without sSS. TO was increased in both groups (329 ± 20 and 319 ± 25 mOsm/L, respectively), but no statistically significant difference was found between the 2 groups (P = 0.126). RA with sSS had significantly shorter TBUT, higher corneal staining score, and ESR CRP levels (P < 0.05). TO did not correlate with the Schirmer test score, but had significant positive correlations with age, corneal staining score, ESR, and CRP levels, and a significant negative correlation with TBUT. TO was increased in RA patients with or without sSS. There was no significant correlation between TO and the Schirmer test score, and the physician could not use TO to diagnose sSS. However, TO correlated well with both DED parameters (TBUT and corneal staining score) and systemic inflammatory markers (ESR and CRP).
Translation and validation of the Dutch new Knee Society Scoring System ©.
Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan
2013-11-01
A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p < 0.001), Dutch KOOS (r = -0.723; p < 0.001), and Dutch SF-12 (r = 0.569; p < 0.001). There was a significant difference between pre- and postoperative scores (p < 0.001) in line with the other scores. Test-retest reliability proved excellent with an intraclass correlation coefficient between 0.73 and 0.92 depending on the domain tested. Consistency as indicated by Cronbach's alpha ranging from 0.84 to 0.96 was good to excellent. As demonstrated by the validation procedure, the Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, Amir; Symons, Rolf; Sandfort, Veit; Mallek, Marissa; Fuld, Matthew K.; Henderson, Gregory; Jones, Elizabeth C.; Malayeri, Ashkan A.; Folio, Les R.
2016-01-01
Purpose To evaluate the performance of a prototype photon-counting detector (PCD) computed tomography (CT) system for abdominal CT in humans and to compare the results with a conventional energy-integrating detector (EID). Materials and Methods The study was HIPAA-compliant and institutional review board–approved with informed consent. Fifteen asymptomatic volunteers (seven men; mean age, 58.2 years ± 9.8 [standard deviation]) were prospectively enrolled between September 2 and November 13, 2015. Radiation dose–matched delayed contrast agent–enhanced spiral and axial abdominal EID and PCD scans were acquired. Spiral images were scored for image quality (Wilcoxon signed-rank test) in five regions of interest by three radiologists blinded to the detector system, and the axial scans were used to assess Hounsfield unit accuracy in seven regions of interest (paired t test). Intraclass correlation coefficient (ICC) was used to assess reproducibility. PCD images were also used to calculate iodine concentration maps. Spatial resolution, noise-power spectrum, and Hounsfield unit accuracy of the systems were estimated by using a CT phantom. Results In both systems, scores were similar for image quality (median score, 4; P = .19), noise (median score, 3; P = .30), and artifact (median score, 1; P = .17), with good interrater agreement (image quality, noise, and artifact ICC: 0.84, 0.88, and 0.74, respectively). Hounsfield unit values, spatial resolution, and noise-power spectrum were also similar with the exception of mean Hounsfield unit value in the spinal canal, which was lower in the PCD than the EID images because of beam hardening (20 HU vs 36.5 HU; P < .001). Contrast-to-noise ratio of enhanced kidney tissue was improved with PCD iodine mapping compared with EID (5.2 ± 1.3 vs 4.0 ± 1.3; P < .001). Conclusion The performance of PCD showed no statistically significant difference compared with EID when the abdomen was evaluated in a conventional scan mode. PCD provides spectral information, which may be used for material decomposition. © RSNA, 2016 PMID:26840654
Assessing fundamental 2-dimensional understanding of basic soft tissue techniques.
Jabbour, Noel; Dobratz, Eric J; Dresner, Harley S; Hilger, Peter A
2011-01-01
To develop a written practical examination and scoring system for assessing trainee skills in basic soft-tissue techniques. A brief written practical examination was developed to assess the ability of trainees to sketch preoperative plans and postoperative results for common soft-tissue techniques: simple-excision, M-plasty, geometric broken line closure, Z-plasty, V-to-Y flap, and rhombic flap. A scoring system was developed to assign 0 to 5 points to each of 10 items on the examination for a total score of 0-50. The 15-minute examination was administered as a pretest, posttest, and 3-month posttest assessment as part of a soft-tissue course at our institution. University of Minnesota, Otolaryngology Department. Three raters reviewed all examination answer sheets independently. The pretest scores of examinees correlated strongly with their level of training; the average pretest for junior residents (PGY 1-2) compared with senior residents (PGY 4-5) was 17.3 (of 50) versus 26.0 (p < 0.01). The scoring system showed a high intrarater reliability and high interrater reliability with correlation coefficients of r = 0.99 and r = 0.95, respectively and agreement coefficients of κ = 0.82 and κ = 0.77, respectively. This written practical examination and scoring system may be used to assess the skills of trainees accurately in basic soft tissue techniques and to expose areas of deficiency that can be addressed in future training sessions. Copyright © 2011 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A N; Lübbert, Michael; Greenberg, Peter L; Bennett, John M; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L; Ohyashiki, Kazuma; Le Beau, Michelle M; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie
2015-02-01
International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%-20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34(+)) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34(+) peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34(+) blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). Copyright© Ferrata Storti Foundation.
Alvarez-Twose, I; González-de-Olano, D; Sánchez-Muñoz, L; Matito, A; Jara-Acevedo, M; Teodosio, C; García-Montero, A; Morgado, J M; Orfao, A; Escribano, L
2012-01-01
A variable percentage of patients with systemic mast cell (MC) activation symptoms meet criteria for systemic mastocytosis (SM). We prospectively evaluated the clinical utility of the REMA score versus serum baseline tryptase (sBt) levels for predicting MC clonality and SM in 158 patients with systemic MC activation symptoms in the absence of mastocytosis in the skin (MIS). World Health Organization criteria for SM were applied in all cases. MC clonality was defined as the presence of KIT-mutated MC or by a clonal HUMARA test. The REMA score consisted of the assignment of positive or negative points as follows: male (+1), female (-1), sBt <15 μg/l (-1) or >25 μg/l (+2), presence (-2) or absence (+1) of pruritus, hives or angioedema and presence (+3) of presyncope or syncope. Efficiency of the REMA score for predicting MC clonality and SM was assessed by receiver operating characteristic (ROC) curve analyses and compared to those obtained by means of sBt levels alone. Molecular studies revealed the presence of clonal MC in 68/80 SM cases and in 11/78 patients who did not meet the criteria for SM. ROC curve analyses confirmed the greater sensitivity and a similar specificity of the REMA score versus sBt levels (84 vs. 59% and 74 vs. 70% for MC clonality and 87 vs. 62% and 73 vs. 71% for SM, respectively). Our results confirm the clinical utility of the REMA score to predict MC clonality and SM in patients suffering from systemic MC activation symptoms without MIS. Copyright © 2011 S. Karger AG, Basel.
[The comparison of the expansion of polyps according to the Ki-67 and computed tomography scores].
Aydin, Sedat; Sanli, Arif; Tezer, Ilter; Hardal, Umit; Barişik, Nagehan Ozdemir
2009-01-01
The disease extention in nasal polyps was compared by using the mitotic activity rates and the computed tomography scores. This study was conducted on 19 nasal polyposis patients (8 males, 11 females; mean age 40.0+/-13.7 years; range 20 to 63 years). The preoperative computed tomography records of the patients were evaluated according to the Lund-Mackay grading system. The polyp tissues of the same patients were stained with the Ki-67 antigen for immunohistochemical evaluation. The correlation between the radiologic results and the Ki-67 values was compared by means of the Spearman's correlation test. The mean computed tomography score was observed as 14.3+/-4.7 (range 7-24). The mean Ki-67 score resulting from the immunohistochemical staining was calculated as 24.3+/-18.5 (range 3.3-73.5%). A significant correlation was determined between the Ki-67 values and the computed tomography scores. ("Spearman's" correlation factor: 0.677; p<0.001). As the mitotic activity rate of nasal polyps increases, both the volume of the polyps and the computed tomography scores increase as a result of the blockage of the sinus ostiums by the increased polyp volume.
Wallace, Daniel J; Gavin, Igor M; Karpenko, Oleksly; Barkhordar, Farnaz; Gillis, Bruce S
2015-06-01
Making a correct diagnosis is pivotal in the practice of clinical rheumatology. Occasionally, the consultation fails to provide desired clarity in making labeling an individual as having fibromyalgia (FM), systemic lupus erythematosus (SLE) or rheumatoid arthritis (RA). A chemokine and cytokine multiplex assay was developed and tested with the goal of improving and achieving an accurate differential diagnosis. 160 patients with FM, 98 with RA and 100 with SLE fulfilling accepted criteria were recruited and compared to 119 controls. Supernatant cytokine concentrations for IL-6, IL-8, MIP-1 alpha and MIP-1 beta were determined using the Luminex multiplex immunoassay bead array technology after mitogenic stimulation of cultured peripheral blood mononuclear cells. Each patient's profile was scored using a logistical regression model to achieve statistically determined weighting for each chemokine and cytokine. Among the 477 patients evaluated, the mean scores for FM (1.7 ± 1.2; 1.52-1.89), controls (-3.56 ± 5.7; -4.59 to -2.54), RA (-0.68 ± 2.26; -1.12 to -0.23) and SLE (-1.45 ± 3.34, -2.1 to -0.79). Ninety-three percent with FM scored positive compared to only 11% of healthy controls, 69% RA or 71% SLE patients had negative scores. The sensitivity, specificity, positive predictive and negative predictive value for having FM compared to controls was 93, 89, 92 and 91%, respectively (p < 2.2 × 10(-16)). Evaluating cytokine and chemokine profiles in stimulated cells reveals patterns that are uniquely present in patients with FM. This assay can be a useful tool in assisting clinicians in differentiating systemic inflammatory autoimmune processes from FM and its related syndromes and healthy individuals.
Hellak, Andreas; Rusdea, Patrick; Schauseil, Michael; Stein, Steffen; Korbmacher-Steiner, Heike Maria
2016-11-01
The aim of this in vitro study was to compare the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances to the commonly used total etch system Transbond XT™ (in combination with phosphoric acid). In all, 60 human premolars were randomly divided into three groups of 20 specimens each. In group 1 (control), brackets were bonded with Transbond™ XT primer. Prompt L-Pop™ (group 2) and Scotchbond™ Universal (group 3) were used in the experimental groups. Lower premolar brackets were bonded by light curing the adhesive. After 24 h of storage, the shear bond strength (SBS) was measured using a Zwicki 1120 testing machine. The adhesive remnant index (ARI) was determined under 10× magnification. The Kruskal-Wallis test was used to statistically compare the SBS and the ARI scores. No significant differences in the SBS between any of the experimental groups were detected (group 1: 15.49 ± 3.28 MPa; group 2: 13.89 ± 4.95 MPa; group 3: 14.35 ± 3.56 MPa; p = 0.489), nor were there any significant differences in the ARI scores (p = 0.368). Using the two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances does not affect either the SBS or ARI scores in comparison with the commonly used total-etch system Transbond™ XT. In addition, Scotchbond™ Universal supports bonding on all types of surfaces (enamel, metal, composite, and porcelain) with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures.
Kasztelan-Szczerbinska, Beata; Slomka, Maria; Celinski, Krzysztof; Szczerbinski, Mariusz
2013-01-01
Determination of risk factors relevant to 90-day prognosis in AH. Comparison of the conventional prognostic models such as Maddrey's modified discriminant function (mDF) and Child-Pugh-Turcotte (CPT) score with newer ones: the Glasgow Alcoholic Hepatitis Score (GAHS); Age, Bilirubin, INR, Creatinine (ABIC) score, Model for End-Stage Liver Disease (MELD), and MELD-Na in the death prediction. The clinical and laboratory variables obtained at admission were assessed. The mDF, CPT, GAHS, ABIC, MELD, and MELD-Na scores' different areas under the curve (AUCs) and the best threshold values were compared. Logistic regression was used to assess predictors of the 90-day outcome. One hundred sixteen pts fulfilled the inclusion criteria. Twenty (17.4%) pts died and one underwent orthotopic liver transplantation (OLT) within 90 days of follow-up. No statistically significant differences in the models' performances were found. Multivariate logistic regression identified CPT score, alkaline phosphatase (AP) level higher than 1.5 times the upper limit of normal (ULN), and corticosteroids (CS) nonresponse as independent predictors of mortality. The CPT score, AP > 1.5 ULN, and the CS nonresponse had an independent impact on the 90-day survival in AH. Accuracy of all studied scoring systems was comparable.
Jenkinson, C; Mant, J; Carter, J; Wade, D; Winner, S
2000-03-01
To assess the validity of the London handicap scale (LHS) using a simple unweighted scoring system compared with traditional weighted scoring 323 patients admitted to hospital with acute stroke were followed up by interview 6 months after their stroke as part of a trial looking at the impact of a family support organiser. Outcome measures included the six item LHS, the Dartmouth COOP charts, the Frenchay activities index, the Barthel index, and the hospital anxiety and depression scale. Patients' handicap score was calculated both using the standard procedure (with weighting) for the LHS, and using a simple summation procedure without weighting (U-LHS). Construct validity of both LHS and U-LHS was assessed by testing their correlations with the other outcome measures. Cronbach's alpha for the LHS was 0.83. The U-LHS was highly correlated with the LHS (r=0.98). Correlation of U-LHS with the other outcome measures gave very similar results to correlation of LHS with these measures. Simple summation scoring of the LHS does not lead to any change in the measurement properties of the instrument compared with standard weighted scoring. Unweighted scores are easier to calculate and interpret, so it is recommended that these are used.
Chevalier, Thérèse M.; Stewart, Garth; Nelson, Monty; McInerney, Robert J.; Brodie, Norman
2016-01-01
It has been well documented that IQ scores calculated using Canadian norms are generally 2–5 points lower than those calculated using American norms on the Wechsler IQ scales. However, recent findings have demonstrated that the difference may be significantly larger for individuals with certain demographic characteristics, and this has prompted discussion about the appropriateness of using the Canadian normative system with a clinical population in Canada. This study compared the interpretive effects of applying the American and Canadian normative systems in a clinical sample. We used a multivariate analysis of variance (ANOVA) to calculate differences between IQ and Index scores in a clinical sample, and mixed model ANOVAs to assess the pattern of differences across age and ability level. As expected, Full Scale IQ scores calculated using Canadian norms were systematically lower than those calculated using American norms, but differences were significantly larger for individuals classified as having extremely low or borderline intellectual functioning when compared with those who scored in the average range. Implications of clinically different conclusions for up to 52.8% of patients based on these discrepancies highlight a unique dilemma facing Canadian clinicians, and underscore the need for caution when choosing a normative system with which to interpret WAIS-IV results in the context of a neuropsychological test battery in Canada. Based on these findings, we offer guidelines for best practice for Canadian clinicians when interpreting data from neuropsychological test batteries that include different normative systems, and suggestions to assist with future test development. PMID:27246955
Gui, Wei; Dombrow, Matthew; Marcus, Inna; Stowe, Meredith H; Tessier-Sherman, Baylah; Yang, Elizabeth; Huang, John J
2015-04-01
To compare vision-related (VR-QOL) and health-related quality of life (HR-QOL) in patients with noninfectious uveitis treated with systemic anti-inflammatory therapy versus nonsystemic therapy. A prospective, cross-sectional study design was employed. VR-QOL and HR-QOL were assessed by the 25-Item Visual Function Questionnaire (VFQ-25) and the Short Form 12-Item Health Survey (SF-12), respectively. Multivariate regression analysis was performed to assess the VR-QOL and HR-QOL based on treatment. Among the 80 patients, the median age was 51 years with 28 males (35%). The adjusted effect of treatment modality on VR-QOL or HR-QOL showed no statistically significant difference in all subscores of VFQ-25 or physical component score (PCS) and mental component score (MCS) of SF-12. Systemic therapy did not compromise VR-QOL or HR-QOL compared to nonsystemic therapy. Systemic therapy can be effectively used to control serious cases of noninfectious uveitis without significant relative adverse impact on quality of life.
The Automated Assessment of Postural Stability: Balance Detection Algorithm.
Napoli, Alessandro; Glass, Stephen M; Tucker, Carole; Obeid, Iyad
2017-12-01
Impaired balance is a common indicator of mild traumatic brain injury, concussion and musculoskeletal injury. Given the clinical relevance of such injuries, especially in military settings, it is paramount to develop more accurate and reliable on-field evaluation tools. This work presents the design and implementation of the automated assessment of postural stability (AAPS) system, for on-field evaluations following concussion. The AAPS is a computer system, based on inexpensive off-the-shelf components and custom software, that aims to automatically and reliably evaluate balance deficits, by replicating a known on-field clinical test, namely, the Balance Error Scoring System (BESS). The AAPS main innovation is its balance error detection algorithm that has been designed to acquire data from a Microsoft Kinect ® sensor and convert them into clinically-relevant BESS scores, using the same detection criteria defined by the original BESS test. In order to assess the AAPS balance evaluation capability, a total of 15 healthy subjects (7 male, 8 female) were required to perform the BESS test, while simultaneously being tracked by a Kinect 2.0 sensor and a professional-grade motion capture system (Qualisys AB, Gothenburg, Sweden). High definition videos with BESS trials were scored off-line by three experienced observers for reference scores. AAPS performance was assessed by comparing the AAPS automated scores to those derived by three experienced observers. Our results show that the AAPS error detection algorithm presented here can accurately and precisely detect balance deficits with performance levels that are comparable to those of experienced medical personnel. Specifically, agreement levels between the AAPS algorithm and the human average BESS scores ranging between 87.9% (single-leg on foam) and 99.8% (double-leg on firm ground) were detected. Moreover, statistically significant differences in balance scores were not detected by an ANOVA test with alpha equal to 0.05. Despite some level of disagreement between human and AAPS-generated scores, the use of an automated system yields important advantages over currently available human-based alternatives. These results underscore the value of using the AAPS, that can be quickly deployed in the field and/or in outdoor settings with minimal set-up time. Finally, the AAPS can record multiple error types and their time course with extremely high temporal resolution. These features are not achievable by humans, who cannot keep track of multiple balance errors with such a high resolution. Together, these results suggest that computerized BESS calculation may provide more accurate and consistent measures of balance than those derived from human experts.
Pickering, Brian W; Hurley, Killian; Marsh, Brian
2009-11-01
To use a handover assessment tool for identifying patient information corruption and objectively evaluating interventions designed to reduce handover errors and improve medical decision making. The continuous monitoring, intervention, and evaluation of the patient in modern intensive care unit practice generates large quantities of information, the platform on which medical decisions are made. Information corruption, defined as errors of distortion/omission compared with the medical record, may result in medical judgment errors. Identifying these errors may lead to quality improvements in intensive care unit care delivery and safety. Handover assessment instrument development study divided into two phases by the introduction of a handover intervention. Closed, 17-bed, university-affiliated mixed surgical/medical intensive care unit. Senior and junior medical members of the intensive care unit team. Electronic handover page. Study subjects were asked to recall clinical information commonly discussed at handover on individual patients. The handover score measured the percentage of information correctly retained for each individual doctor-patient interaction. The clinical intention score, a subjective measure of medical judgment, was graded (1-5) by three blinded intensive care unit experts. A total of 137 interactions were scored. Median (interquartile range) handover scores for phases 1 and 2 were 79.07% (67.44-84.50) and 83.72% (76.16-88.37), respectively. Score variance was reduced by the handover intervention (p < .05). Increasing median handover scores, 68.60 to 83.72, were associated with increases in clinical intention scores from 1 to 5 (chi-square = 23.59, df = 4, p < .0001). When asked to recall clinical information discussed at handover, medical members of the intensive care unit team provide data that are significantly corrupted compared with the medical record. Low subjective clinical judgment scores are significant associated with low handover scores. The handover/clinical intention scores may, therefore, be useful screening tools for intensive care unit system vulnerability to medical error. Additionally, handover instruments can identify interventions that reduce system vulnerability to error and may be used to guide quality improvements in handover practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltrán-Esteve, Mercedes, E-mail: mercedes.beltran@uv.es; Reig-Martínez, Ernest; Estruch-Guitart, Vicent
Sustainability analysis requires a joint assessment of environmental, social and economic aspects of production processes. Here we propose the use of Life Cycle Analysis (LCA), a metafrontier (MF) directional distance function (DDF) approach, and Data Envelopment Analysis (DEA), to assess technological and managerial differences in eco-efficiency between production systems. We use LCA to compute six environmental and health impacts associated with the production processes of nearly 200 Spanish citrus farms belonging to organic and conventional farming systems. DEA is then employed to obtain joint economic-environmental farm's scores that we refer to as eco-efficiency. DDF allows us to determine farms' globalmore » eco-efficiency scores, as well as eco-efficiency scores with respect to specific environmental impacts. Furthermore, the use of an MF helps us to disentangle technological and managerial eco-inefficiencies by comparing the eco-efficiency of both farming systems with regards to a common benchmark. Our core results suggest that the shift from conventional to organic farming technology would allow a potential reduction in environmental impacts of 80% without resulting in any decline in economic performance. In contrast, as regards farmers' managerial capacities, both systems display quite similar mean scores.« less
Effects of losartan on experimental varicocele-induced testicular germ cell apoptosis.
Bolat, D; Oltulu, F; Uysal, A; Kose, T; Gunlusoy, B; Yigitturk, G; Turk, N S; Turan, T
2016-09-01
To investigate the potential protective effects of losartan on varicocele-induced germ cell apoptosis, 24 adult male Sprague Dawley rats were divided into three groups: a sham operation was performed in SHAM group, and experimental left varicocele was created in VAR and VAR + LOS groups. Additionally, in VAR + LOS group, losartan was administered for 30 days starting on the day of surgery. At the end of 30 days, all animals were sacrificed and left orchiectomy was performed. Testicular injury and spermatogenesis were evaluated according to Johnsen scoring system. To assess the nitrosative stress, immunohistochemical staining for endothelial nitric oxide synthase was used and evaluated by H-score and apoptotic index (AI) of germ cells was analysed by TUNEL method. A significant decrease in the mean Johnsen score (JS) was observed in VAR group compared with SHAM (p < .001). The mean H-score and AI were significantly higher in VAR group compared with SHAM (p < .001). After losartan administration, mean JS was significantly increased (p < .001) and mean H-score and AI were significantly decreased compared with VAR group (p < .001 and .01, respectively). Findings of this suggest that losartan acts as a potent protective agent against varicocele-induced germ cell apoptosis. © 2016 Blackwell Verlag GmbH.
Performance in physical examination on the USMLE Step 2 Clinical Skills examination.
Peitzman, Steven J; Cuddy, Monica M
2015-02-01
To provide descriptive information about history-taking (HX) and physical examination (PE) performance for U.S. medical students as documented by standardized patients (SPs) during the Step 2 Clinical Skills (CS) component of the United States Medical Licensing Examination. The authors examined two hypotheses: (1) Students perform worse in PE compared with HX, and (2) for PE, students perform worse in the musculoskeletal system and neurology compared with other clinical domains. The sample included 121,767 student-SP encounters based on 29,442 examinees from U.S. medical schools who took Step 2 CS for the first time in 2011. The encounters comprised 107 clinical presentations, each categorized into one of five clinical domains: cardiovascular, gastrointestinal, musculoskeletal, neurological, and respiratory. The authors compared mean percent-correct scores for HX and PE via a one-tailed paired-samples t test and examined mean score differences by clinical domain using analysis of variance techniques. Average PE scores (59.6%) were significantly lower than average HX scores (78.1%). The range of scores for PE (51.4%-72.7%) was larger than for HX (74.4%-81.0%), and the standard deviation for PE scores (28.3) was twice as large as the HX standard deviation (14.7). PE performance was significantly weaker for musculoskeletal and neurological encounters compared with other encounters. U.S. medical students perform worse on PE than HX; PE performance was weakest in musculoskeletal and neurology clinical domains. Findings may reflect imbalances in U.S. medical education, but more research is needed to fully understand the relationships among PE instruction, assessment, and proficiency.
Leong, K P; Chong, E Y Y; Kong, K O; Chan, S P; Thong, B Y H; Lian, T Y; Chng, H H; Koh, E T; Teh, C L; Lau, T C; Law, W G; Cheng, Y K; Badsha, H; Chew, L C; Yong, W H; Howe, H S
2010-01-01
Patients with systemic lupus erythematosus often assess their disease activity differently from their physicians. We studied the factors associated with this discordance. The data provided by 534 systemic lupus erythematosus patients were analyzed. We compared the physician and patient assessments of lupus activity on a visual-assessment scale from the same visit. We collected clinical data and scores from MOS 36-Item Short-Form Health Survey, Systemic Lupus Erythematosus Quality-of-Life Questionnaire, Rheumatology Attitudes Index, Systemic Lupus Erythematosus Disease Activity Index, and revised Systemic Lupus Activity Measure. Patients tended to score their disease activity higher than do their physicians, when these factors were present: poorer general health assessment, presence of thrombocytopenia, hypertension and urinary sediments, and difficulty in carrying groceries. Physicians tended to score the disease activity higher than do the patients in these circumstances proteinuria, hemolysis, use of azathioprine or cyclophosphamide, tiredness, photosensitivity, higher revised Systemic Lupus Activity Measure score, casturia, and patient report of being more easily ill than are other patients. There was only moderate correlation between the discordance in the baseline and the subsequent visits. The physician assessment of disease activity at baseline correlated better with an objective measure of disease activity (revised Systemic Lupus Activity Measure) in the subsequent visit than the patient assessment. In conclusion, discordance in the perception of disease activity between patients and physicians may be amenable to intervention.
Sano, Yuko; Okuyama, Chio; Iehara, Tomoko; Matsushima, Shigenori; Yamada, Kei; Hosoi, Hajime; Nishimura, Tsunehiko
2012-07-01
The purpose of this study is to evaluate a new semi-quantitative estimation method using (123)I-MIBG retention ratio to assess response to chemotherapy for advanced neuroblastoma. Thirteen children with advanced neuroblastoma (International Neuroblastoma Risk Group Staging System: stage M) were examined for a total of 51 studies with (123)I-MIBG scintigraphy (before and during chemotherapy). We proposed a new semi-quantitative method using MIBG retention ratio (count obtained with delayed image/count obtained with early image with decay correction) to estimate MIBG accumulation. We analyzed total (123)I-MIBG retention ratio (TMRR: total body count obtained with delayed image/total body count obtained with early image with decay correction) and compared with a scoring method in terms of correlation with tumor markers. TMRR showed significantly higher correlations with urinary catecholamine metabolites before chemotherapy (VMA: r(2) = 0.45, P < 0.05, HVA: r(2) = 0.627, P < 0.01) than MIBG score (VMA: r(2) = 0.19, P = 0.082, HVA: r(2) = 0.25, P = 0.137). There were relatively good correlations between serial change of TMRR and those of urinary catecholamine metabolites (VMA: r(2) = 0.274, P < 0.001, HVA: r(2) = 0.448, P < 0.0001) compared with serial change of MIBG score and those of tumor markers (VMA: r(2) = 0.01, P = 0.537, HVA: 0.084, P = 0.697) during chemotherapy for advanced neuroblastoma. TMRR could be a useful semi-quantitative method for estimating early response to chemotherapy of advanced neuroblastoma because of its high correlation with urine catecholamine metabolites.
Kwakkenbos, Linda; Willems, Linda M; Baron, Murray; Hudson, Marie; Cella, David; van den Ende, Cornelia H M; Thombs, Brett D
2014-01-01
The Functional Assessment of Chronic Illness Therapy-Fatigue (FACIT-F) is commonly used to assess fatigue in rheumatic diseases, and has shown to discriminate better across levels of the fatigue spectrum than other commonly used measures. The aim of this study was to assess the cross-language measurement equivalence of the English, French, and Dutch versions of the FACIT-F in systemic sclerosis (SSc) patients. The FACIT-F was completed by 871 English-speaking Canadian, 238 French-speaking Canadian and 230 Dutch SSc patients. Confirmatory factor analysis was used to assess the factor structure in the three samples. The Multiple-Indicator Multiple-Cause (MIMIC) model was utilized to assess differential item functioning (DIF), comparing English versus French and versus Dutch patient responses separately. A unidimensional factor model showed good fit in all samples. Comparing French versus English patients, statistically significant, but small-magnitude DIF was found for 3 of 13 items. French patients had 0.04 of a standard deviation (SD) lower latent fatigue scores than English patients and there was an increase of only 0.03 SD after accounting for DIF. For the Dutch versus English comparison, 4 items showed small, but statistically significant, DIF. Dutch patients had 0.20 SD lower latent fatigue scores than English patients. After correcting for DIF, there was a reduction of 0.16 SD in this difference. There was statistically significant DIF in several items, but the overall effect on fatigue scores was minimal. English, French and Dutch versions of the FACIT-F can be reasonably treated as having equivalent scoring metrics.
Kwakkenbos, Linda; Willems, Linda M.; Baron, Murray; Hudson, Marie; Cella, David; van den Ende, Cornelia H. M.; Thombs, Brett D.
2014-01-01
Objective The Functional Assessment of Chronic Illness Therapy- Fatigue (FACIT-F) is commonly used to assess fatigue in rheumatic diseases, and has shown to discriminate better across levels of the fatigue spectrum than other commonly used measures. The aim of this study was to assess the cross-language measurement equivalence of the English, French, and Dutch versions of the FACIT-F in systemic sclerosis (SSc) patients. Methods The FACIT-F was completed by 871 English-speaking Canadian, 238 French-speaking Canadian and 230 Dutch SSc patients. Confirmatory factor analysis was used to assess the factor structure in the three samples. The Multiple-Indicator Multiple-Cause (MIMIC) model was utilized to assess differential item functioning (DIF), comparing English versus French and versus Dutch patient responses separately. Results A unidimensional factor model showed good fit in all samples. Comparing French versus English patients, statistically significant, but small-magnitude DIF was found for 3 of 13 items. French patients had 0.04 of a standard deviation (SD) lower latent fatigue scores than English patients and there was an increase of only 0.03 SD after accounting for DIF. For the Dutch versus English comparison, 4 items showed small, but statistically significant, DIF. Dutch patients had 0.20 SD lower latent fatigue scores than English patients. After correcting for DIF, there was a reduction of 0.16 SD in this difference. Conclusions There was statistically significant DIF in several items, but the overall effect on fatigue scores was minimal. English, French and Dutch versions of the FACIT-F can be reasonably treated as having equivalent scoring metrics. PMID:24638101
Statistically Comparing the Performance of Multiple Automated Raters across Multiple Items
ERIC Educational Resources Information Center
Kieftenbeld, Vincent; Boyer, Michelle
2017-01-01
Automated scoring systems are typically evaluated by comparing the performance of a single automated rater item-by-item to human raters. This presents a challenge when the performance of multiple raters needs to be compared across multiple items. Rankings could depend on specifics of the ranking procedure; observed differences could be due to…
A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders
Karbassi, Izabela; Maston, Glenn A.; Love, Angela; DiVincenzo, Christina; Braastad, Corey D.; Elzinga, Christopher D.; Bright, Alison R.; Previte, Domenic; Zhang, Ke; Rowland, Charles M.; McCarthy, Michele; Lapierre, Jennifer L.; Dubois, Felicita; Medeiros, Katelyn A.; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A.; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller‐Burckle, Arlene; Strom, Charles M.; Keiles, Steven B.
2015-01-01
ABSTRACT We developed a rules‐based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co‐occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re‐evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. PMID:26467025
A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders.
Karbassi, Izabela; Maston, Glenn A; Love, Angela; DiVincenzo, Christina; Braastad, Corey D; Elzinga, Christopher D; Bright, Alison R; Previte, Domenic; Zhang, Ke; Rowland, Charles M; McCarthy, Michele; Lapierre, Jennifer L; Dubois, Felicita; Medeiros, Katelyn A; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller-Burckle, Arlene; Strom, Charles M; Keiles, Steven B; Higgins, Joseph J
2016-01-01
We developed a rules-based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co-occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re-evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. © 2015 The Authors. **Human Mutation published by Wiley Periodicals, Inc.
Reduction Continuous Rank Probability Score for Hydrological Ensemble Prediction System
NASA Astrophysics Data System (ADS)
Trinh, Nguyen Bao; Thielen Del-Pozo, Jutta; Pappenberger, Florian; Cloke, Hannah L.; Bogner, Konrad
2010-05-01
Ensemble Prediction System (EPS), calculated operationally by the weather services for various lead-times, are increasingly used as input to hydrological models to extend warning times from short- to medium and even long-range. Although the general skill of EPS has been demonstrated to increase continuously over the past decades, it remains comparatively low for precipitation, one of the driving forces of hydrological processes. Due to the non-linear integrating nature of river runoff and the complexities of catchment runoff processes, one cannot assume that the skill of the hydrological forecasts is necessarily similar to the skill of the meteorological predictions. Furthermore, due to the integrating nature of discharge, which accumulates effects from upstream catchment and slow-responding groundwater processes, commonly applied skill scores in meteorology may not be fully adapted to describe the skill of probabilistic discharge predictions. For example, while for hydrological applications it may be interesting to compare the forecast skill between upstream and downstream stations, meteorological applications focus more on climatologically relevant regions. In this paper, a range of widely used probabilistic skill scores for assessing reliability, spread-skill, sharpness and bias are calculated for a 12 months case study in the Danube river basin. The Continuous Rank Probability Score (CRPS) is demonstrated to have deficiencies when comparing skill of discharge forecast for different hydrological stations. Therefore, we propose a modified CRPS that allows this comparison and is therefore particularly useful for hydrological applications.
Bressel, Eadric; Yonker, Joshua C; Kras, John; Heath, Edward M
2007-01-01
Context: How athletes from different sports perform on balance tests is not well understood. When prescribing balance exercises to athletes in different sports, it may be important to recognize performance variations. Objective: To compare static and dynamic balance among collegiate athletes competing or training in soccer, basketball, and gymnastics. Design: A quasi-experimental, between-groups design. Independent variables included limb (dominant and nondominant) and sport played. Setting: A university athletic training facility. Patients or Other Participants: Thirty-four female volunteers who competed in National Collegiate Athletic Association Division I soccer (n = 11), basketball (n = 11), or gymnastics (n = 12). Intervention(s): To assess static balance, participants performed 3 stance variations (double leg, single leg, and tandem leg) on 2 surfaces (stiff and compliant). For assessment of dynamic balance, participants performed multidirectional maximal single-leg reaches from a unilateral base of support. Main Outcome Measure(s): Errors from the Balance Error Scoring System and normalized leg reach distances from the Star Excursion Balance Test were used to assess static and dynamic balance, respectively. Results: Balance Error Scoring System error scores for the gymnastics group were 55% lower than for the basketball group (P = .01), and Star Excursion Balance Test scores were 7% higher in the soccer group than the basketball group (P = .04). Conclusions: Gymnasts and soccer players did not differ in terms of static and dynamic balance. In contrast, basketball players displayed inferior static balance compared with gymnasts and inferior dynamic balance compared with soccer players. PMID:17597942
Rius-Vilarrasa, E; Bünger, L; Maltin, C; Matthews, K R; Roehe, R
2009-05-01
The Meat and Livestock Commission's (MLC) EUROP classification based scheme and Video Image Analysis (VIA) system were compared in their ability to predict weights of primal carcass joints. A total of 443 commercial lamb carcasses under 12 months of age and mixed gender were selected by their cold carcass weight (CCW), conformation and fat scores. Lamb carcasses were classified for conformation and fatness, scanned by the VIA system and dissected into primal joints of leg, chump, loin, breast and shoulder. After adjustment for CCW, the estimation of primal joints using MLC EUROP scores showed high coefficients of determination (R(2)) in the range of 0.82-0.99. The use of VIA always resulted in equal or higher R(2). The precision measured as root mean square error (RMSE) was 27% (leg), 13% (chump), 1% (loin), 11% (breast), 5% (shoulders) and 13% (total primals) higher using VIA than MLC carcass information. Adjustment for slaughter day and gender effects indicated that estimations of primal joints using MLC EUROP scores were more sensitive to these factors than using VIA. This was consistent with an increase in stability of the prediction model of 28%, 11%, 2%, 12%, 6% and 14% for leg, chump, loin, breast and shoulder and total primals, respectively, using VIA compared to MLC EUROP scores. Consequently, VIA was capable of improving the prediction of primal meat yields compared to the current MLC EUROP carcass classification scheme used in the UK abattoirs.
Ramesh Kumar, S G; Aswath Narayanan, M B; Jayanthi, D
2016-01-01
Immune mechanism shares a common pathway both for systemic autoimmune diseases and periodontal diseases. Scientific exploration of literature revealed limited studies on the association between systemic autoimmune diseases and periodontal diseases in India. The aim of the study is to find whether the presence of systemic autoimmune diseases in an individual is a risk factor for the development of periodontal disease. This was a hospital-based case-control study. A sample of 253 patients with systemic autoimmune diseases, attending the Rheumatology Department of Government General Hospital, Chennai-3, and 262 patients without systemic autoimmune diseases, attending the outpatient department of the Tamil Nadu Government Dental College and Hospital, Chennai-3, constituted the case and control groups, respectively. Age, gender, and oral hygiene status matching was done. Oral hygiene status was assessed using oral hygiene index (OHI) and periodontal status was assessed using community periodontal index (CPI) and loss of attachment (LOA) index. Statistical analysis was done using SPSS version 15 (SPSS Inc, 2006, Chicago). Results showed 99.2% and 73.9% prevalence of gingivitis and periodontitis, respectively, in the case group as compared to 85.5% and 14.9%, respectively, in the control group. There is no linear relationship between OHI scores and prevalence of periodontitis (CPI and LOA scores) in the case group. Patients suffering from systemic autoimmune diseases showed more prevalence of periodontal diseases irrespective of oral hygiene scores. It is postulated that the presence of systemic autoimmune diseases may pose a risk for the development of periodontal diseases.
Nicholson, Allen D; Huez, Coridon M; Sanders, James O; Liu, Raymond W; Cooperman, Daniel R
2016-03-01
In 2 recent studies, modified Oxford hip scores of 16 through 18 have been shown to predict an extremely high risk of contralateral slipping in unilateral slipped capital femoral epiphysis (SCFE). However, the modified Oxford system is not widely used. This may be due, in part, to the complexity of the scoring system, difficulty in viewing all 5 radiographic features on a single x-ray and phenotypic variation in the features. Ossification of the calcaneal apophysis provides an osteologic marker of skeletal maturation in relation to peak height velocity and has been described previously. We examine the value of the calcaneal apophyseal ossification sequence for predicting modified Oxford hip scores. We examined 279 pelvis and matching foot x-rays that were taken at the same session from 94 healthy children aged 3 to 18 years. A fellowship-trained pediatric orthopaedist determined the modified Oxford hip score for each hip radiograph. The calcaneal x-rays had been previously graded. Modified Oxford hip scores were compared with calcaneal scores for each set of matched hip and calcaneal x-rays. Stage 0 to 2 calcanei had 94% of corresponding hip radiographs rated as modified Oxford scores of 16 to 18. Stage 3 calcanei had 54% rated as 16 to 18 and 31% rated as scores 19 to 21. Stage 4 calcanei had 31% rated as scores 19 to 21, and 68% rated as scores 22 to 26. Stage 5 calcanei had 100% rated as 22 to 26. Using data from Popejoy and colleagues' study, the weighted risk of contralateral SCFE was 94% for calcaneal stage 0, 86.5% for calcaneal stage 1, 90.3% for calcaneal stage 2, 55.8% for calcaneal stage 3, 6.1% for calcaneal stage 4, and 0 for calcaneal stage 5. Calcaneal stages 0 to 3 correspond entirely to modified Oxford scores indicating elevated risk of contralateral SCFE. The calcaneal scoring system has potential for adjunctive use with the modified Oxford score for prediction of contralateral SCFE.
Development of a Flipped Medical School Dermatology Module.
Fox, Joshua; Faber, David; Pikarsky, Solomon; Zhang, Chi; Riley, Richard; Mechaber, Alex; O'Connell, Mark; Kirsner, Robert S
2017-05-01
The flipped classroom module incorporates independent study in advance of in-class instructional sessions. It is unproven whether this methodology is effective within a medical school second-year organ system module. We report the development, implementation, and effectiveness of the flipped classroom methodology in a second-year medical student dermatology module at the University of Miami Leonard M. Miller School of Medicine. In a retrospective cohort analysis, we compared attitudinal survey data and mean scores for a 50-item multiple-choice final examination of the second-year medical students who participated in this 1-week flipped course with those of the previous year's traditional, lecture-based course. Each group comprised nearly 200 students. Students' age, sex, Medical College Admission Test scores, and undergraduate grade point averages were comparable between the flipped and traditional classroom students. The flipped module students' mean final examination score of 92.71% ± 5.03% was greater than that of the traditional module students' 90.92% ± 5.51% ( P < 0.001) score. Three of the five most commonly missed questions were identical between the two cohorts. The majority of students preferred the flipped methodology to attending live lectures or watching previously recorded lectures. The flipped classroom can be an effective instructional methodology for a medical school second-year organ system module.
Gislason-Lee, Amber J.; Keeble, Claire; Egleston, Daniel; Bexon, Josephine; Kengyelics, Stephen M.; Davies, Andrew G.
2017-01-01
Abstract. This study aimed to determine whether a reduction in radiation dose was found for percutaneous coronary interventional (PCI) patients using a cardiac interventional x-ray system with state-of-the-art image enhancement and x-ray optimization, compared to the current generation x-ray system, and to determine the corresponding impact on clinical image quality. Patient procedure dose area product (DAP) and fluoroscopy duration of 131 PCI patient cases from each x-ray system were compared using a Wilcoxon test on median values. Significant reductions in patient dose (p≪0.001) were found for the new system with no significant change in fluoroscopy duration (p=0.2); procedure DAP reduced by 64%, fluoroscopy DAP by 51%, and “cine” acquisition DAP by 76%. The image quality of 15 patient angiograms from each x-ray system (30 total) was scored by 75 clinical professionals on a continuous scale for the ability to determine the presence and severity of stenotic lesions; image quality scores were analyzed using a two-sample t-test. Image quality was reduced by 9% (p≪0.01) for the new x-ray system. This demonstrates a substantial reduction in patient dose, from acquisition more than fluoroscopy imaging, with slightly reduced image quality, for the new x-ray system compared to the current generation system. PMID:28491907
Cuthbert, Jennifer A; Arslanlar, Sami; Yepuri, Jay; Montrose, Marc; Ahn, Chul W; Shah, Jessica P
2014-07-01
No study has evaluated current scoring systems for their accuracy in predicting short and long-term outcome of alcoholic hepatitis in a US population. We reviewed electronic records for patients with alcoholic liver disease (ALD) admitted to Parkland Memorial Hospital between January 2002 and August 2005. Data and outcomes for 148 of 1,761 admissions meeting pre-defined criteria were collected. The discriminant function (DF) was revised (INRdf) to account for changes in prothrombin time reagents that could potentially affect identification of risk using the previous DF threshold of >32. Admission and theoretical peak scores were calculated by use of the Model for End-stage Liver Disease (MELD). Analysis models compared five different scoring systems. INRdf was closely correlated with the old DF (r (2) = 0.95). Multivariate analysis of the data showed that survival for 28 days was significantly associated with a scoring system using a combination of age, bilirubin, coagulation status, and creatinine (p < 0.001), and an elevated ammonia result within two days of admission (p = 0.012). When peak values for MELD were included, they were the most significant predictor of short-term mortality (p < 0.001), followed by INRdf (p = 0.006). On admission, two scoring systems that identify a subset of patients with severe alcoholic liver disease are able to predict >50 % mortality at four weeks and >80 % mortality at six months without specific treatment.
Al Amrani, Fatema; Marcovitz, Jaclyn; Sanon, Priscille-Nice; Khairy, May; Saint-Martin, Christine; Shevell, Michael; Wintermark, Pia
2018-05-01
To determine whether an MRI scoring system, which was validated in the pre-cooling era, can still predict the neurodevelopmental outcome of asphyxiated newborns treated with hypothermia at 2 years of age. We conducted a retrospective cohort study of asphyxiated newborns treated with hypothermia. An MRI scoring system, which was validated in the pre-cooling era, was used to grade the severity of brain injury on the neonatal brain MRI. Their neurodevelopment was assessed around 2 years of age; adverse outcome included cerebral palsy, global developmental delay, and/or epilepsy. One hundred and sixty-nine newborns were included. Among the 131 newborns who survived and had a brain MRI during the neonatal period, 92% were evaluated around 2 years of age or later. Of these newborns, 37% displayed brain injury, and 23% developed an adverse outcome. Asphyxiated newborns treated with hypothermia who had an adverse outcome had a significantly higher MRI score (p <0.001) compared to those without an adverse outcome. An MRI scoring system that was validated before the cooling era is still able to reliably differentiate which of the asphyxiated newborns treated with hypothermia were more prone to develop an adverse outcome around 2 years of age. Copyright © 2018 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Performance Evaluation of Fusing Protected Fingerprint Minutiae Templates on the Decision Level
Yang, Bian; Busch, Christoph; de Groot, Koen; Xu, Haiyun; Veldhuis, Raymond N. J.
2012-01-01
In a biometric authentication system using protected templates, a pseudonymous identifier is the part of a protected template that can be directly compared. Each compared pair of pseudonymous identifiers results in a decision testing whether both identifiers are derived from the same biometric characteristic. Compared to an unprotected system, most existing biometric template protection methods cause to a certain extent degradation in biometric performance. Fusion is therefore a promising way to enhance the biometric performance in template-protected biometric systems. Compared to feature level fusion and score level fusion, decision level fusion has not only the least fusion complexity, but also the maximum interoperability across different biometric features, template protection and recognition algorithms, templates formats, and comparison score rules. However, performance improvement via decision level fusion is not obvious. It is influenced by both the dependency and the performance gap among the conducted tests for fusion. We investigate in this paper several fusion scenarios (multi-sample, multi-instance, multi-sensor, multi-algorithm, and their combinations) on the binary decision level, and evaluate their biometric performance and fusion efficiency on a multi-sensor fingerprint database with 71,994 samples. PMID:22778583
ERIC Educational Resources Information Center
Haga, Wayne; Moreno, Abel; Segall, Mark
2012-01-01
In this paper, we compare the performance of Computer Information Systems (CIS) majors on the Information Systems Analyst (ISA) Certification Exam. The impact that the form of delivery of information systems coursework may have on the exam score is studied. Using a sample that spans three years, we test for significant differences between scores…
[Toronto clinical scoring system in diabetic peripheral neuropathy].
Liu, Feng; Mao, Ji-Ping; Yan, Xiang
2008-12-01
To evaluate the application value of Toronto clinical scoring system (TCSS) and its grading of neuropathy for diabetic peripheral neuropathy (DPN), and to explore the relationship between TCSS grading of neuropathy and the grading of diabetic nephropathy and diabetic retinopathy. A total of 209 patients of Type 2 diabtes (T2DM) underwent TCSS. Taking electrophysiological examination as a gold standard for diagnosing DPN, We compared the results of TCSS score > or = 6 with electrophysiological examination, and tried to select the optimal cut-off points of TCSS. The corresponding accuracy, sensitivity, and specificity of TCSS score > or = 6 were 76.6%, 77.2%, and 75.6%, respectively.The Youden index and Kappa were 0.53 and 0.52, which implied TCSS score > or = 6 had a moderate consistency with electrophysiological examination. There was a linear positive correlation between TCSS grading of neuropathy and the grading of diabetic nephropathy and diabetic retinopathy (P<0.05). The optimal cut-off point was 5 or 6 among these patients. TCSS is reliable in diagnosing DPN and its grading of neuropathy has clinical value.
Using E-Readers and Internet Resources to Support Comprehension
ERIC Educational Resources Information Center
Wright, Sandra; Fugett, April; Caputa, Francine
2013-01-01
The advancements of technology have led to the use of electronic reading systems for digital text. Research indicates similarities and differences in reading performance and comprehension in digital formats compared to paper formats. This study compared vocabulary understanding and reading comprehension scores from two reading sources (electronic…
Baron-Cohen, Simon; Richler, Jennifer; Bisarya, Dheraj; Gurunathan, Nhishanth; Wheelwright, Sally
2003-01-01
Systemizing is the drive to analyse systems or construct systems. A recent model of psychological sex differences suggests that this is a major dimension in which the sexes differ, with males being more drawn to systemize than females. Currently, there are no self-report measures to assess this important dimension. A second major dimension of sex differences is empathizing (the drive to identify mental states and respond to these with an appropriate emotion). Previous studies find females score higher on empathy measures. We report a new self-report questionnaire, the Systemizing Quotient (SQ), for use with adults of normal intelligence. It contains 40 systemizing items and 20 control items. On each systemizing item, a person can score 2, 1 or 0, so the SQ has a maximum score of 80 and a minimum of zero. In Study 1, we measured the SQ of n = 278 adults (114 males, 164 females) from a general population, to test for predicted sex differences (male superiority) in systemizing. All subjects were also given the Empathy Quotient (EQ) to test if previous reports of female superiority would be replicated. In Study 2 we employed the SQ and the EQ with n = 47 adults (33 males, 14 females) with Asperger syndrome (AS) or high-functioning autism (HFA), who are predicted to be either normal or superior at systemizing, but impaired at empathizing. Their scores were compared with n = 47 matched adults from the general population in Study 1. In Study 1, as predicted, normal adult males scored significantly higher than females on the SQ and significantly lower on the EQ. In Study 2, again as predicted, adults with AS/HFA scored significantly higher on the SQ than matched controls, and significantly lower on the EQ than matched controls. The SQ reveals both a sex difference in systemizing in the general population and an unusually strong drive to systemize in AS/HFA. These results are discussed in relation to two linked theories: the 'empathizing-systemizing' (E-S) theory of sex differences and the extreme male brain (EMB) theory of autism. PMID:12639333
SU-E-T-192: FMEA Severity Scores - Do We Really Know?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonigan, J; Johnson, J; Kry, S
2014-06-01
Purpose: Failure modes and effects analysis (FMEA) is a subjective risk mitigation technique that has not been applied to physics-specific quality management practices. There is a need for quantitative FMEA data as called for in the literature. This work focuses specifically on quantifying FMEA severity scores for physics components of IMRT delivery and comparing to subjective scores. Methods: Eleven physical failure modes (FMs) for head and neck IMRT dose calculation and delivery are examined near commonly accepted tolerance criteria levels. Phantom treatment planning studies and dosimetry measurements (requiring decommissioning in several cases) are performed to determine the magnitude of dosemore » delivery errors for the FMs (i.e., severity of the FM). Resultant quantitative severity scores are compared to FMEA scores obtained through an international survey and focus group studies. Results: Physical measurements for six FMs have resulted in significant PTV dose errors up to 4.3% as well as close to 1 mm significant distance-to-agreement error between PTV and OAR. Of the 129 survey responses, the vast majority of the responders used Varian machines with Pinnacle and Eclipse planning systems. The average years of experience was 17, yet familiarity with FMEA less than expected. Survey reports perception of dose delivery error magnitude varies widely, in some cases 50% difference in dose delivery error expected amongst respondents. Substantial variance is also seen for all FMs in occurrence, detectability, and severity scores assigned with average variance values of 5.5, 4.6, and 2.2, respectively. Survey shows for MLC positional FM(2mm) average of 7.6% dose error expected (range 0–50%) compared to 2% error seen in measurement. Analysis of ranking in survey, treatment planning studies, and quantitative value comparison will be presented. Conclusion: Resultant quantitative severity scores will expand the utility of FMEA for radiotherapy and verify accuracy of FMEA results compared to highly variable subjective scores.« less
Orzechowski, Kelly M; Edgerton, Elizabeth A; Bulas, Dorothy I; McLaughlin, Patrick M; Eichelberger, Martin R
2003-06-01
Injury patterns among children in frontal collisions have been well documented, but little information exists regarding injuries to children in side impact collisions. Restrained children 14-years-old or younger admitted to the hospital for crash injuries were analyzed. Data concerning injuries, medical treatment, and outcome were correlated with crash data. Case reviews achieved consensus regarding injury contact points. Side impacts were compared with frontal impacts. These results were then compared with data from the National Automotive Sampling System. There were no differences between the groups with respect to age, sex, restraint type, or seat position. Compared with frontal crashes, children in side impacts were more likely to have an Injury Severity Score > 15 (odds ratio [OR], 3.1; 95% confidence interval [CI], 1.7-5.8) and were more likely to have Abbreviated Injury Scale score 2+ injuries to the head (OR, 2.5; 95% CI, 1.4-4.4), chest (OR, 4.0; 95% CI, 2.0-8.0), and cervical spine (OR, 3.7; 95% CI, 1.2-11.3). When compared with National Automotive Sampling System data, similar trends were seen regarding Abbreviated Injury Scale score 2+ injuries to the head, chest, and extremities. In this study population, side impacts resulted in more injuries to the head, cervical spine, and chest. Knowledge of this pattern-the side impact syndrome-can help guide diagnosis, treatment, and prevention strategy.
Dabbs, Gretchen R; Bytheway, Joan A; Connor, Melissa
2017-09-01
When in forensic casework or empirical research in-person assessment of human decomposition is not possible, the sensible substitution is color photographic images. To date, no research has confirmed the utility of color photographic images as a proxy for in situ observation of the level of decomposition. Sixteen observers scored photographs of 13 human cadavers in varying decomposition stages (PMI 2-186 days) using the Total Body Score system (total n = 929 observations). The on-site TBS was compared with recorded observations from digital color images using a paired samples t-test. The average difference between on-site and photographic observations was -0.20 (t = -1.679, df = 928, p = 0.094). Individually, only two observers, both students with <1 year of experience, demonstrated TBS statistically significantly different than the on-site value, suggesting that with experience, observations of human decomposition based on digital images can be substituted for assessments based on observation of the corpse in situ, when necessary. © 2017 American Academy of Forensic Sciences.
Rathnakar, Surag Kajoor; Vishnu, Vikram Hubbanageri; Muniyappa, Shridhar; Prasath, Arun
2017-02-01
Acute Pancreatitis (AP) is one of the common conditions encountered in the emergency room. The course of the disease ranges from mild form to severe acute form. Most of these episodes are mild and spontaneously subsiding within 3 to 5 days. In contrast, Severe Acute Pancreatitis (SAP) occurring in around 15-20% of all cases, mortality can range between 10 to 85% across various centres and countries. In such a situation we need an indicator which can predict the outcome of an attack, as severe or mild, as early as possible and such an indicator should be sensitive and specific enough to trust upon. PANC-3 scoring is such a scoring system in predicting the outcome of an attack of AP. To assess the accuracy and predictability of PANC-3 scoring system over APACHE II in predicting severity in an attack of AP. This prospective study was conducted on 82 patients admitted with the diagnosis of pancreatitis. Investigations to evaluate PANC-3 and APACHE II were done on all the patients and the PANC-3 and APACHE II score was calculated. PANC-3 score has a sensitivity of 82.6% and specificity of 77.9%, the test had a Positive Predictive Value (PPV) of 0.59 and Negative Predictive Value (NPV) of 0.92. Sensitivity of APACHE II in predicting SAP was 91.3% and specificity was 96.6% with PPV of 0.91, NPV was 0.96. Our study shows that PANC-3 can be used to predict the severity of pancreatitis as efficiently as APACHE II. The interpretation of PANC-3 does not need expertise and can be applied at the time of admission which is an advantage when compared to classical scoring systems.
BILAG-2004 index captures systemic lupus erythematosus disease activity better than SLEDAI-2000.
Yee, C-S; Isenberg, D A; Prabu, A; Sokoll, K; Teh, L-S; Rahman, A; Bruce, I N; Griffiths, B; Akil, M; McHugh, N; D'Cruz, D; Khamashta, M A; Maddison, P; Zoma, A; Gordon, C
2008-06-01
To assess the reliability of Systemic Lupus Erythematosus Disease Activity Index (SLEDAI)-2000 index in routine practice and its ability to capture disease activity as compared with the British Isles Lupus Assessment Group (BILAG)-2004 index. Patients with systemic lupus erythematosus from 11 centres were assessed separately by two raters in routine practice. Disease activity was assessed using the BILAG-2004 and SLEDAI-2000 indices. The level of agreement for items was used to assess the reliability of SLEDAI-2000. The ability to detect disease activity was assessed by determining the number of patients with a high activity on BILAG-2004 (overall score A or B) but low SLEDAI-2000 score (<6) and number of patients with low activity on BILAG-2004 (overall score C, D or E) but high SLEDAI-2000 score (>or=6). Treatment of these patients was analysed, and the increase in treatment was used as the gold standard for active disease. 93 patients (90.3% women, 69.9% Caucasian) were studied: mean age was 43.8 years, mean disease duration 10 years. There were 43 patients (46.2%) with a difference in SLEDAI-2000 score between the two raters and this difference was >or=4 in 19 patients (20.4%). Agreement for each of the items in SLEDAI-2000 was between 81.7 and 100%. 35 patients (37.6%) had high activity on BILAG-2004 but a low SLEDAI-2000 score, of which 48.6% had treatment increased. There were only five patients (5.4%) with low activity on BILAG-2004 but a high SLEDAI-2000 score. SLEDAI-2000 is a reliable index to assess systemic lupus erythematosus disease activity but it is less able than the BILAG-2004 index to detect active disease requiring increased treatment.
Complications among colorectal cancer survivors: SF-6D preference-weighted quality of life scores.
Hornbrook, Mark C; Wendel, Christopher S; Coons, Stephen Joel; Grant, Marcia; Herrinton, Lisa J; Mohler, M Jane; Baldwin, Carol M; McMullen, Carmit K; Green, Sylvan B; Altschuler, Andrea; Rawl, Susan M; Krouse, Robert S
2011-03-01
Societal preference-weighted health-related quality of life (HRQOL) scores enable comparing multidimensional health states across diseases and treatments for research and policy. To assess the effects of living with a permanent intestinal stoma, compared with a major bowel resection, among colorectal cancer (CRC) survivors. Cross-sectional multivariate linear regression analysis to explain preference-weighted HRQOL scores. In all, 640 CRC survivors (≥ 5 years) from 3 group model health maintenance organizations; ostomates and nonostomates with colorectal resections for CRC were matched on gender, age (± 5 years), time since diagnosis, and tumor site (rectum vs. colon). SF-6D scoring system was applied to Medical Outcomes Study Short Form-36 version 2 (SF-36v2); City of Hope Quality of Life-Ostomy; and Charlson-Deyo comorbidity index. Survey of CRC survivors linked to respondents' clinical data extracted from health maintenance organization files. Response rate was 52%. Ostomates and nonostomates had similar sociodemographic characteristics. Mean SF-6D score was 0.69 for ostomates, compared with 0.73 for nonostomates (P < 0.001), but other factors explained this difference. Complications of initial cancer surgery, and previous year comorbidity burden, and hospital use were negatively associated with SF-6D scores, whereas household income was positively associated. CRC survivors' SF-6D scores were not associated with living with a permanent ostomy after other factors were taken into account. Surgical complications, comorbidities, and metastatic disease lowered the preference-weighted HRQOL of CRC survivors with and without ostomies. Further research to understand and reduce late complications from CRC surgeries as well as associated depression is warranted.
Perceived stress and its predictors in people with epilepsy.
Moon, Hye-Jin; Seo, Jong-Geun; Park, Sung-Pa
2016-09-01
Perceived stress in people with epilepsy (PWE) is one of the major precipitants for seizures. We investigated the degree of perceived stress in PWE and its predictors. We also aimed to reveal the interrelationships among the predictors. This was a case-control study. Consecutive patients visiting a tertiary care epilepsy clinic completed self-reported questionnaires including the Perceived Stress Scale (PSS), Revised Stigma Scale (RSS), Korean version of the Neurological Disorders Depression Inventory for Epilepsy (K-NDDI-E), Generalized Anxiety Disorder - 7 (GAD-7), and short forms of the Patient-Reported Outcomes Measurement Information System - Sleep Disturbance (PROMIS-SD) and Patient-Reported Outcomes Measurement Information System - Sleep-Related Impairment (PROMIS-SRI) scales. The mean score of the PSS was significantly lower in patients with well-controlled epilepsy (WCE) and higher in those with uncontrolled epilepsy compared with controls. Although several factors including demographic, socioeconomic, psychosomatic, and epilepsy-related factors were associated with the PSS score, the strongest predictor for the PSS score was the K-NDDI-E score, followed by the PROMIS-SRI score, the GAD-7 score, and seizure control. Psychosomatic factors exerted both a direct effect on the PSS score and an indirect effect on the PSS score through seizure control. Rapid detection and appropriate management of psychiatric and sleep-related problems in PWE may lessen stress and aid in preventing further seizures. Copyright © 2016 Elsevier Inc. All rights reserved.
Protective effect of ebselen on experimental testicular torsion and detorsion injury.
Rifaioglu, M M; Motor, S; Davarci, I; Tuzcu, K; Sefil, F; Davarci, M; Nacar, A
2014-12-01
Ebselen is used as a drug in clinical trials against stroke, reperfusion injury with anti-atherosclerotic and renoprotective effects. The aim of this study is to investigate the protective effect of ebselen, on torsion/detorsion (T/D)-induced biochemical and histopathological changes in experimental testicular ischaemia/reperfusion injury. A total of 28 male Wistar Albino rats were divided into four groups: group 1(sham-operated group, n = 7), group 2(ebselen group, n = 7), group 3(torsion/detorsion + saline, n = 7) and group 4(T/D + 10 mg kg(-1) ebselen group, n = 7). The tissue homogenate samples were used for immediate nitric oxide (NO), malondialdehyde (MDA), superoxide dismutase, catalase and glutathione measurement. Testes in all groups were evaluated for the biochemical assay and histopathological examinations. To evaluate spermatogenesis, Johnsen scoring system was used. Testicular tissue MDA and NO levels in group 3 were significantly higher than in group 1 and 4. In histological evaluation of the testicular tissues, ebselen administration improved tubular histology significantly compared with T/D group. Significant increase in histological score was observed in the testis of group 3 compared with group 1 and 2. Histological score in group 4 significantly decreased compared with group 3. Johnson score was significantly lower in T/D group compared with all other three groups, ebselen administration increased the score significantly compared with T/D group. Ebselen reduced oxidative biochemical and histopathological damage in our testicular T/D rat model. © 2013 Blackwell Verlag GmbH.
External validation of scoring systems in risk stratification of upper gastrointestinal bleeding.
Anchu, Anna Cherian; Mohsina, Subair; Sureshkumar, Sathasivam; Mahalakshmy, T; Kate, Vikram
2017-03-01
The aim of this study was to externally validate the four commonly used scoring systems in the risk stratification of patients with upper gastrointestinal bleed (UGIB). Patients of UGIB who underwent endoscopy within 24 h of presentation were stratified prospectively using the pre-endoscopy Rockall score (PRS) >0, complete Rockall score (CRS) >2, Glasgow Blatchford bleeding scores (GBS) >3, and modified GBS (m-GBS) >3 scores. Patients were followed up to 30 days. Prognostic accuracy of the scores was done by comparing areas under curve (AUC) in terms of overall risk stratification, re-bleeding, mortality, need for intervention, and length of hospitalization. One hundred and seventy-five patients were studied. All four scores performed better in the overall risk stratification on AUC [PRS = 0.566 (CI: 0.481-0.651; p-0.043)/CRS = 0.712 (CI: 0.634-0.790); p<0.001)/GBS = 0.810 (CI: 0.744-0.877; p->0.001); m-GBS = 0.802 (CI: 0.734-0.871; p<0.001)], whereas only CRS achieved significance in identifying re-bleed [AUC-0.679 (CI: 0.579-0.780; p = 0.003)]. All the scoring systems except PRS were found to be significantly better in detecting 30-day mortality with a high AUC (CRS = 0.798; p-0.042)/GBS = 0.833; p-0.023); m-GBS = 0.816; p-0.031). All four scores demonstrated significant accuracy in the risk stratification of non-variceal patients; however, only GBS and m-GBS were significant in variceal etiology. Higher cutoff scores achieved better sensitivity/specificity [RS > 0 (50/60.8), CRS > 1 (87.5/50.6), GBS > 7 (88.5/63.3), m-GBS > 7(82.3/72.6)] in the risk stratification. GBS and m-GBS appear to be more valid in risk stratification of UGIB patients in this region. Higher cutoff values achieved better predictive accuracy.
Frequency of inflammatory-like MR imaging findings in asymptomatic fingers of healthy volunteers.
Agten, Christoph A; Rosskopf, Andrea B; Jonczy, Maciej; Brunner, Florian; Pfirrmann, Christian W A; Buck, Florian M
2018-02-01
To describe the frequency of inflammatory-like findings on MR imaging in asymptomatic volunteers and compare them with patients with known rheumatoid arthritis and psoriatic arthritis. MR images of fingers in 42 asymptomatic volunteers and 33 patients with rheumatoid/psoriatic arthritis were analyzed. The Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid/Psoriatic Arthritis MRI Scoring System (RAMRIS/PsAMRIS) and tenosynovitis scoring system were used to assess: bone marrow edema (BME), erosions, tendon sheath fluid/tenosynovitis, joint effusion, and soft-tissue edema. Findings and scores were compared between volunteers and patients. Inter-reader agreement was calculated (intraclass correlation coefficients, ICC). In volunteers, tendon sheath fluid was very common in at least one location (42/42 volunteers for reader 1, 34/42 volunteers for reader 2). BME, erosions, joint effusion, and soft-tissue edema were absent (except one BME in the 3rd proximal phalanx for reader 1). Tendon sheath fluid scores in volunteers and tenosynovitis scores in patients were high (reader 1, 7.17 and 5.39; reader 2, 2.31 and 5.45). Overall, inter-reader agreement was substantial (ICC = 0.696-0.844), except for tendon sheath fluid (ICC = 0.258). Fluid in the finger flexor tendon sheaths may be a normal finding and without gadolinium administration should not be interpreted as tenosynovitis. Bone marrow edema, erosions, joint effusion, and soft-tissue edema in the fingers most likely reflect pathology if present.
SPIDERplan: A tool to support decision-making in radiation therapy treatment plan assessment.
Ventura, Tiago; Lopes, Maria do Carmo; Ferreira, Brigida Costa; Khouri, Leila
2016-01-01
In this work, a graphical method for radiotherapy treatment plan assessment and comparison, named SPIDERplan, is proposed. It aims to support plan approval allowing independent and consistent comparisons of different treatment techniques, algorithms or treatment planning systems. Optimized plans from modern radiotherapy are not easy to evaluate and compare because of their inherent multicriterial nature. The clinical decision on the best treatment plan is mostly based on subjective options. SPIDERplan combines a graphical analysis with a scoring index. Customized radar plots based on the categorization of structures into groups and on the determination of individual structures scores are generated. To each group and structure, an angular amplitude is assigned expressing the clinical importance defined by the radiation oncologist. Completing the graphical evaluation, a global plan score, based on the structures score and their clinical weights, is determined. After a necessary clinical validation of the group weights, SPIDERplan efficacy, to compare and rank different plans, was tested through a planning exercise where plans had been generated for a nasal cavity case using different treatment planning systems. SPIDERplan method was applied to the dose metrics achieved by the nasal cavity test plans. The generated diagrams and scores successfully ranked the plans according to the prescribed dose objectives and constraints and the radiation oncologist priorities, after a necessary clinical validation process. SPIDERplan enables a fast and consistent evaluation of plan quality considering all targets and organs at risk.
A Longitudinal Comparison of Systems Used to Identify Subgroups of Learning Disabled Children.
ERIC Educational Resources Information Center
Goldstein, David; Dundon, William D.
This paper addresses the problem of heterogeneity of samples of learning disabled (LD) children by comparing five different systems for identifying homogeneous subgroups in terms of their ability to predict longitudinal reading and mathematics scores. One hundred and sixty LD children served as subjects. Three of the five subgrouping systems were…
Automatic generation of the index of productive syntax for child language transcripts.
Hassanali, Khairun-nisa; Liu, Yang; Iglesias, Aquiles; Solorio, Thamar; Dollaghan, Christine
2014-03-01
The index of productive syntax (IPSyn; Scarborough (Applied Psycholinguistics 11:1-22, 1990) is a measure of syntactic development in child language that has been used in research and clinical settings to investigate the grammatical development of various groups of children. However, IPSyn is mostly calculated manually, which is an extremely laborious process. In this article, we describe the AC-IPSyn system, which automatically calculates the IPSyn score for child language transcripts using natural language processing techniques. Our results show that the AC-IPSyn system performs at levels comparable to scores computed manually. The AC-IPSyn system can be downloaded from www.hlt.utdallas.edu/~nisa/ipsyn.html .
Rodríguez-Mañero, Moisés; Abu Assi, Emad; Sánchez-Gómez, Juan Miguel; Fernández-Armenta, Juan; Díaz-Infante, Ernesto; García-Bolao, Ignacio; Benezet-Mazuecos, Juan; Andrés Lahuerta, Ana; Expósito-García, Víctor; Bertomeu-González, Vicente; Arce-León, Álvaro; Barrio-López, María Teresa; Peinado, Rafael; Martínez-Sande, Luis; Arias, Miguel A
2016-11-01
Several clinical risk scores have been developed to identify patients at high risk of all-cause mortality despite implantation of an implantable cardioverter-defibrillator. We aimed to examine and compare the predictive capacity of 4 simple scoring systems (MADIT-II, FADES, PACE and SHOCKED) for predicting mortality after defibrillator implantation for primary prevention of sudden cardiac death in a Mediterranean country. A multicenter retrospective study was performed in 15 Spanish hospitals. Consecutive patients referred for defibrillator implantation between January 2010 and December 2011 were included. A total of 916 patients with ischemic and nonischemic heart disease were included (mean age, 62 ± 11 years, 81.4% male). Over 33.4 ± 12.9 months, 113 (12.3%) patients died (cardiovascular origin in 86 [9.4%] patients). At 12, 24, 36, and 48 months, mortality rates were 4.5%, 7.6%, 10.8%, and 12.3% respectively. All the risk scores showed a stepwise increase in the risk of death throughout the scoring system of each of the scores and all 4 scores identified patients at greater risk of mortality. The scores were significantly associated with all-cause mortality throughout the follow-up period. PACE displayed the lowest c-index value regardless of whether the population had heart disease of ischemic (c-statistic = 0.61) or nonischemic origin (c-statistic = 0.61), whereas MADIT-II (c-statistic = 0.67 and 0.65 in ischemic and nonischemic cardiomyopathy, respectively), SHOCKED (c-statistic = 0.68 and 0.66, respectively), and FADES (c-statistic = 0.66 and 0.60) provided similar c-statistic values (P ≥ .09). In this nontrial-based cohort of Mediterranean patients, the 4 evaluated risk scores showed a significant stepwise increase in the risk of death. Among the currently available risk scores, MADIT-II, FADES, and SHOCKED provide slightly better performance than PACE. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
A comparative MRI study of cartilage damage in gout versus rheumatoid arthritis.
Popovich, Ivor; Lee, Arier C L; Doyle, Anthony; McHaffie, Alexandra; Clarke, Andrew; Reeves, Quentin; Dalbeth, Nicola; McQueen, Fiona M
2015-08-01
Magnetic resonance imaging (MRI) is useful for detecting joint inflammation and damage in the inflammatory arthropathies. This study aimed to investigate MRI cartilage damage and its associations with joint inflammation in patients with gout compared with a group with rheumatoid arthritis (RA). Forty patients with gout and 38 with seropositive RA underwent 3T-MRI of the wrist with assessment of cartilage damage at six carpal sites, using established scoring systems. Synovitis and bone oedema (BME) were graded according to Rheumatoid Arthritis MRI Scoring System criteria. Cartilage damage was compared between the groups adjusting for synovitis and disease duration using logistic regression analysis. Compared with RA, there were fewer sites of cartilage damage and lower total damage scores in the gout group (P = 0.02 and 0.003), adjusting for their longer disease duration and lesser degree of synovitis. Cartilage damage was strongly associated with synovitis in both conditions (R = 0.59, P < 0.0001 and R = 0.52, P = 0.0045 respectively) and highly correlated with BME in RA (R = 0.69, P < 0.0001) but not in gout (R = 0.095, P = 0.56). Cartilage damage is less severe in gout than in RA, with fewer sites affected and lower overall scores. It is associated with synovitis in both diseases, likely indicating an effect of pro-inflammatory cytokine production on cartilage integrity. However, the strong association between cartilage damage and BME observed in RA was not identified in gout. This emphasizes differences in the underlying pathophysiology of joint damage in these two conditions. © 2015 The Royal Australian and New Zealand College of Radiologists.
Santiago-Torres, Margarita; Tinker, Lesley F; Allison, Matthew A; Breymeyer, Kara L; Garcia, Lorena; Kroenke, Candyce H; Lampe, Johanna W; Shikany, James M; Van Horn, Linda; Neuhouser, Marian L
2015-12-01
Women of Mexican descent are disproportionally affected by obesity, systemic inflammation, and insulin resistance (IR). Available approaches used to give scores to dietary patterns relative to dietary guidelines may not effectively capture traditional diets of Mexicans, who comprise the largest immigrant group in the United States. We characterized an a priori traditional Mexican diet (MexD) score high in corn tortillas, beans, soups, Mexican mixed dishes (e.g., tamales), fruits, vegetables, full-fat milk, and Mexican cheeses and low in refined grains and added sugars and evaluated the association of the MexD score with systemic inflammation and IR in 493 postmenopausal participants in the Women's Health Initiative (WHI) who are of Mexican ethnic descent. The MexD score was developed from the baseline (1993-1998) WHI food frequency questionnaire, which included Hispanic foods and was available in Spanish. Body mass index (BMI) was computed from baseline measured weight and height, and ethnicity was self-reported. Outcome variables were high sensitivity C-reactive protein (hsCRP), glucose, insulin, homeostasis model assessment of insulin resistance (HOMA-IR), and triglyceride concentrations measured at follow-up (2012-2013). Multivariable linear and logistic regression models were used to test the associations of the MexD score with systemic inflammation and IR. The mean ± SD MexD score was 5.8 ± 2.1 (12 maximum points) and was positively associated with intakes of carbohydrates, vegetable protein, and dietary fiber and inversely associated with intakes of added sugars and total fat (P < 0.01). Women with high compared with low MexD scores, consistent with a more-traditional Mexican diet, had 23% and 15% lower serum hsCRP (P < 0.05) and insulin concentrations, respectively (P < 0.05). Baseline BMI modified these associations such that lower MexD scores were associated with higher insulin and HOMA-IR in overweight/obese women (P-interaction <0.05). These findings suggest that greater adherence to a traditional Mexican diet could help reduce the future risk of systemic inflammation and IR in women of Mexican descent. © 2015 American Society for Nutrition.
Santiago-Torres, Margarita; Tinker, Lesley F; Allison, Matthew A; Breymeyer, Kara L; Garcia, Lorena; Kroenke, Candyce H; Lampe, Johanna W; Shikany, James M; Van Horn, Linda; Neuhouser, Marian L
2015-01-01
Background: Women of Mexican descent are disproportionally affected by obesity, systemic inflammation, and insulin resistance (IR). Available approaches used to give scores to dietary patterns relative to dietary guidelines may not effectively capture traditional diets of Mexicans, who comprise the largest immigrant group in the United States. Objectives: We characterized an a priori traditional Mexican diet (MexD) score high in corn tortillas, beans, soups, Mexican mixed dishes (e.g., tamales), fruits, vegetables, full-fat milk, and Mexican cheeses and low in refined grains and added sugars and evaluated the association of the MexD score with systemic inflammation and IR in 493 postmenopausal participants in the Women’s Health Initiative (WHI) who are of Mexican ethnic descent. Methods: The MexD score was developed from the baseline (1993–1998) WHI food frequency questionnaire, which included Hispanic foods and was available in Spanish. Body mass index (BMI) was computed from baseline measured weight and height, and ethnicity was self-reported. Outcome variables were high sensitivity C-reactive protein (hsCRP), glucose, insulin, homeostasis model assessment of insulin resistance (HOMA-IR), and triglyceride concentrations measured at follow-up (2012–2013). Multivariable linear and logistic regression models were used to test the associations of the MexD score with systemic inflammation and IR. Results: The mean ± SD MexD score was 5.8 ± 2.1 (12 maximum points) and was positively associated with intakes of carbohydrates, vegetable protein, and dietary fiber and inversely associated with intakes of added sugars and total fat (P < 0.01). Women with high compared with low MexD scores, consistent with a more-traditional Mexican diet, had 23% and 15% lower serum hsCRP (P < 0.05) and insulin concentrations, respectively (P < 0.05). Baseline BMI modified these associations such that lower MexD scores were associated with higher insulin and HOMA-IR in overweight/obese women (P-interaction <0.05). Conclusion: These findings suggest that greater adherence to a traditional Mexican diet could help reduce the future risk of systemic inflammation and IR in women of Mexican descent. PMID:26491126
Chi-square-based scoring function for categorization of MEDLINE citations.
Kastrin, A; Peterlin, B; Hristovski, D
2010-01-01
Text categorization has been used in biomedical informatics for identifying documents containing relevant topics of interest. We developed a simple method that uses a chi-square-based scoring function to determine the likelihood of MEDLINE citations containing genetic relevant topic. Our procedure requires construction of a genetic and a nongenetic domain document corpus. We used MeSH descriptors assigned to MEDLINE citations for this categorization task. We compared frequencies of MeSH descriptors between two corpora applying chi-square test. A MeSH descriptor was considered to be a positive indicator if its relative observed frequency in the genetic domain corpus was greater than its relative observed frequency in the nongenetic domain corpus. The output of the proposed method is a list of scores for all the citations, with the highest score given to those citations containing MeSH descriptors typical for the genetic domain. Validation was done on a set of 734 manually annotated MEDLINE citations. It achieved predictive accuracy of 0.87 with 0.69 recall and 0.64 precision. We evaluated the method by comparing it to three machine-learning algorithms (support vector machines, decision trees, naïve Bayes). Although the differences were not statistically significantly different, results showed that our chi-square scoring performs as good as compared machine-learning algorithms. We suggest that the chi-square scoring is an effective solution to help categorize MEDLINE citations. The algorithm is implemented in the BITOLA literature-based discovery support system as a preprocessor for gene symbol disambiguation process.
NASA Astrophysics Data System (ADS)
Nassiri, Isar; Lombardo, Rosario; Lauria, Mario; Morine, Melissa J.; Moyseos, Petros; Varma, Vijayalakshmi; Nolen, Greg T.; Knox, Bridgett; Sloper, Daniel; Kaput, Jim; Priami, Corrado
2016-07-01
The investigation of the complex processes involved in cellular differentiation must be based on unbiased, high throughput data processing methods to identify relevant biological pathways. A number of bioinformatics tools are available that can generate lists of pathways ranked by statistical significance (i.e. by p-value), while ideally it would be desirable to functionally score the pathways relative to each other or to other interacting parts of the system or process. We describe a new computational method (Network Activity Score Finder - NASFinder) to identify tissue-specific, omics-determined sub-networks and the connections with their upstream regulator receptors to obtain a systems view of the differentiation of human adipocytes. Adipogenesis of human SBGS pre-adipocyte cells in vitro was monitored with a transcriptomic data set comprising six time points (0, 6, 48, 96, 192, 384 hours). To elucidate the mechanisms of adipogenesis, NASFinder was used to perform time-point analysis by comparing each time point against the control (0 h) and time-lapse analysis by comparing each time point with the previous one. NASFinder identified the coordinated activity of seemingly unrelated processes between each comparison, providing the first systems view of adipogenesis in culture. NASFinder has been implemented into a web-based, freely available resource associated with novel, easy to read visualization of omics data sets and network modules.
Soluble CD163 is increased in patients with acute pancreatitis independent of disease severity.
Karrasch, Thomas; Brünnler, Tanja; Hamer, Okka W; Schmid, Karin; Voelk, Markus; Herfarth, Hans; Buechler, Christa
2015-10-01
Macrophages are crucially involved in the pathophysiology of acute pancreatitis. Soluble CD163 (sCD163) is specifically released from macrophages and systemic levels are increased in inflammatory diseases. Here, sCD163 was measured in serum of 50 patients with acute pancreatitis to find out possible associations with disease activity. Admission levels of systemic sCD163 were nearly three-fold higher in patients with acute pancreatitis compared to controls. In patients sCD163 did not correlate with C-reactive protein and leukocyte count as established markers of inflammation. Levels were not associated with disease severity assessed by the Schroeder score, Balthazar score, Acute Physiology, Age, and Chronic Health Evaluation (Apache) II score and peripancreatic necrosis score. Soluble CD163 was not related to complications of acute pancreatitis. These data show that serum sCD163 is increased in acute pancreatitis indicating activation of macrophages but is not associated with disease severity and outcome. Copyright © 2015 Elsevier Inc. All rights reserved.
Minefield reconnaissance and detector system
Butler, M.T.; Cave, S.P.; Creager, J.D.; Johnson, C.M.; Mathes, J.B.; Smith, K.J.
1994-04-26
A multi-sensor system is described for detecting the presence of objects on the surface of the ground or buried just under the surface, such as anti-personnel or anti-tank mines or the like. A remote sensor platform has a plurality of metal detector sensors and a plurality of short pulse radar sensors. The remote sensor platform is remotely controlled from a processing and control unit and signals from the remote sensor platform are sent to the processing and control unit where they are individually evaluated in separate data analysis subprocess steps to obtain a probability score for each of the pluralities of sensors. These probability scores are combined in a fusion subprocess step by comparing score sets to a probability table which is derived based upon the historical incidence of object present conditions given that score set. A decision making rule is applied to provide an output which is optionally provided to a marker subprocess for controlling a marker device to mark the location of found objects. 7 figures.
Comparison of an expert system with other clinical scores for the evaluation of severity of asthma.
Gautier, V; Rédier, H; Pujol, J L; Bousquet, J; Proudhon, H; Michel, C; Daurès, J P; Michel, F B; Godard, P
1996-01-01
"Asthmaexpert" was produced at the special request of several clinicians in order to obtain a better understanding of the medical decisions taken by clinical experts in the management of asthmatic patients. In order to assess the severity of asthma, a new score called Artificial Intelligence score (AI score), produced by Asthmaexpert, was compared with three other scores (Aas, Hargreave and Brooks). One hundred patients were enrolled prospectively in the study during their first consultation in the out-patient clinic. Distribution of severity level according to the different scores was studied, and the reliability between AI and other scores was evaluated by Kappa and MacNemar tests. Correlations with functional parameters were performed. The AI score assessed higher levels of severity than the other scores (Kappa = 18, 28 and 10% for Aas, Hargreave and Brooks, respectively) with significant MacNemar test in all cases. There was a significant correlation between AI score and forced expiratory volume in one second (FEV1) (r = 0.73). These data indicate that the AI score is a severity score which defines higher levels of severity than the chosen scores. Correlations for functional parameters are good. This score appears easy to use for the first consultation of an asthmatic patient.
Iino, Chikara; Mikami, Tatsuya; Igarashi, Takasato; Aihara, Tomoyuki; Ishii, Kentaro; Sakamoto, Jyuichi; Tono, Hiroshi; Fukuda, Shinsaku
2016-11-01
Multiple scoring systems have been developed to predict outcomes in patients with upper gastrointestinal bleeding. We determined how well these and a newly established scoring model predict the need for therapeutic intervention, excluding transfusion, in Japanese patients with upper gastrointestinal bleeding. We reviewed data from 212 consecutive patients with upper gastrointestinal bleeding. Patients requiring endoscopic intervention, operation, or interventional radiology were allocated to the therapeutic intervention group. Firstly, we compared areas under the curve for the Glasgow-Blatchford, Clinical Rockall, and AIMS65 scores. Secondly, the scores and factors likely associated with upper gastrointestinal bleeding were analyzed with a logistic regression analysis to form a new scoring model. Thirdly, the new model and the existing model were investigated to evaluate their usefulness. Therapeutic intervention was required in 109 patients (51.4%). The Glasgow-Blatchford score was superior to both the Clinical Rockall and AIMS65 scores for predicting therapeutic intervention need (area under the curve, 0.75 [95% confidence interval, 0.69-0.81] vs 0.53 [0.46-0.61] and 0.52 [0.44-0.60], respectively). Multivariate logistic regression analysis retained seven significant predictors in the model: systolic blood pressure <100 mmHg, syncope, hematemesis, hemoglobin <10 g/dL, blood urea nitrogen ≥22.4 mg/dL, estimated glomerular filtration rate ≤ 60 mL/min per 1.73 m 2 , and antiplatelet medication. Based on these variables, we established a new scoring model with superior discrimination to those of existing scoring systems (area under the curve, 0.85 [0.80-0.90]). We developed a superior scoring model for identifying therapeutic intervention need in Japanese patients with upper gastrointestinal bleeding. © 2016 Japan Gastroenterological Endoscopy Society.
Mutale, Wilbroad; Godfrey-Fausset, Peter; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Chintu, Namwinga; Balabanova, Dina; Spicer, Neil; Ayles, Helen
2013-01-01
Introduction There is growing interest in health system performance and recently WHO launched a report on health systems strengthening emphasising the need for close monitoring using system-wide approaches. One recent method is the balanced scorecard system. There is limited application of this method in middle- and low-income countries. This paper applies the concept of balanced scorecard to describe the baseline status of three intervention districts in Zambia. Methodology The Better Health Outcome through Mentoring and Assessment (BHOMA) project is a randomised step-wedged community intervention that aims to strengthen the health system in three districts in the Republic of Zambia. To assess the baseline status of the participating districts we used a modified balanced scorecard approach following the domains highlighted in the MOH 2011 Strategic Plan. Results Differences in performance were noted by district and residence. Finance and service delivery domains performed poorly in all study districts. The proportion of the health workers receiving training in the past 12 months was lowest in Kafue (58%) and highest in Luangwa district (77%). Under service capacity, basic equipment and laboratory capacity scores showed major variation, with Kafue and Luangwa having lower scores when compared to Chongwe. The finance domain showed that Kafue and Chongwe had lower scores (44% and 47% respectively). Regression model showed that children's clinical observation scores were negatively correlated with drug availability (coeff −0.40, p = 0.02). Adult clinical observation scores were positively association with adult service satisfaction score (coeff 0.82, p = 0.04) and service readiness (coeff 0.54, p = 0.03). Conclusion The study applied the balanced scorecard to describe the baseline status of 42 health facilities in three districts of Zambia. Differences in performance were noted by district and residence in most domains with finance and service delivery performing poorly in all study districts. This tool could be valuable in monitoring and evaluation of health systems. PMID:23555590
Mutale, Wilbroad; Godfrey-Fausset, Peter; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Chintu, Namwinga; Balabanova, Dina; Spicer, Neil; Ayles, Helen
2013-01-01
There is growing interest in health system performance and recently WHO launched a report on health systems strengthening emphasising the need for close monitoring using system-wide approaches. One recent method is the balanced scorecard system. There is limited application of this method in middle- and low-income countries. This paper applies the concept of balanced scorecard to describe the baseline status of three intervention districts in Zambia. The Better Health Outcome through Mentoring and Assessment (BHOMA) project is a randomised step-wedged community intervention that aims to strengthen the health system in three districts in the Republic of Zambia. To assess the baseline status of the participating districts we used a modified balanced scorecard approach following the domains highlighted in the MOH 2011 Strategic Plan. Differences in performance were noted by district and residence. Finance and service delivery domains performed poorly in all study districts. The proportion of the health workers receiving training in the past 12 months was lowest in Kafue (58%) and highest in Luangwa district (77%). Under service capacity, basic equipment and laboratory capacity scores showed major variation, with Kafue and Luangwa having lower scores when compared to Chongwe. The finance domain showed that Kafue and Chongwe had lower scores (44% and 47% respectively). Regression model showed that children's clinical observation scores were negatively correlated with drug availability (coeff -0.40, p = 0.02). Adult clinical observation scores were positively association with adult service satisfaction score (coeff 0.82, p = 0.04) and service readiness (coeff 0.54, p = 0.03). The study applied the balanced scorecard to describe the baseline status of 42 health facilities in three districts of Zambia. Differences in performance were noted by district and residence in most domains with finance and service delivery performing poorly in all study districts. This tool could be valuable in monitoring and evaluation of health systems.
Responsiveness of the health insurance and private systems in Alexandria, Egypt.
Mosallam, Rasha A; Aly, Mahmoud M; Moharram, Ahmed M
2013-04-01
Responsiveness to patients is a key indicator for measuring the health system performance with respect to nonhealth aspects. This study aimed to compare responsiveness of the Health Insurance Organization (HIO) with the private healthcare system and also to assess the importance of the different responsiveness domains according to the study population's perspective. Patients attending both inpatient and outpatient settings of both organizations were interviewed (200 outpatients and 200 inpatients from each selected hospital) using the WHO questionnaire. The questionnaire elicits the ratings of the respondents on their experiences with the healthcare system over the past 12 months in terms of responsiveness domains, respondents' inability to access medical care because of financial barriers, and their ranking of the relative importance of responsiveness domains. Almost twice the number of HIO participants reported poor responsiveness compared with the private organization participants (27.8 vs. 56.8%, respectively). The outpatient setting scored much favorably compared with the inpatient setting at the HIO (52.3% of respondents reported poor responsiveness in the outpatient setting compared with 76.3% in the inpatient setting); however, they were comparable in the private setting. Communication, prompt attention, and dignity were the domains most frequently rated as the most important (36.0, 32.0, and 14.7%, respectively). The type of organization (HIO vs. private organization) and setting of care (inpatient vs. outpatient) were significant predictors of responsiveness score (P<0.001). The overall rating of the patients on responsiveness of the HIO system is low, especially when compared with the private sector. The results emphasize the importance of establishment of systems for monitoring the performance of the providers and discontinuation of the services for the nonperformers.
Balasubramanian, Bijal A.; Garcia, Michael P.; Corley, Douglas A.; Doubeni, Chyke A.; Haas, Jennifer S.; Kamineni, Aruna; Quinn, Virginia P.; Wernli, Karen; Zheng, Yingye; Skinner, Celette Sugg
2017-01-01
Abstract Previous research shows that patients in integrated health systems experience fewer racial disparities compared with more traditional healthcare systems. Little is known about patterns of racial/ethnic disparities between safety-net and non safety-net integrated health systems. We evaluated racial/ethnic differences in body mass index (BMI) and the Charlson comorbidity index from 3 non safety-net- and 1 safety-net integrated health systems in a cross-sectional study. Multinomial logistic regression modeled comorbidity and BMI on race/ethnicity and health care system type adjusting for age, sex, insurance, and zip-code-level income The study included 1.38 million patients. Higher proportions of safety-net versus non safety-net patients had comorbidity score of 3+ (11.1% vs. 5.0%) and BMI ≥35 (27.7% vs. 15.8%). In both types of systems, blacks and Hispanics were more likely than whites to have higher BMIs. Whites were more likely than blacks or Hispanics to have higher comorbidity scores in a safety net system, but less likely to have higher scores in the non safety-nets. The odds of comorbidity score 3+ and BMI 35+ in blacks relative to whites were significantly lower in safety-net than in non safety-net settings. Racial/ethnic differences were present within both safety-net and non safety-net integrated health systems, but patterns differed. Understanding patterns of racial/ethnic differences in health outcomes in safety-net and non safety-net integrated health systems is important to tailor interventions to eliminate racial/ethnic disparities in health and health care. PMID:28296752
Lucca, Ilaria; de Martino, Michela; Hofbauer, Sebastian L; Zamani, Nura; Shariat, Shahrokh F; Klatte, Tobias
2015-12-01
Pretreatment measurements of systemic inflammatory response, including the Glasgow prognostic score (GPS), the neutrophil-to-lymphocyte ratio (NLR), the monocyte-to-lymphocyte ratio (MLR), the platelet-to-lymphocyte ratio (PLR) and the prognostic nutritional index (PNI) have been recognized as prognostic factors in clear cell renal cell carcinoma (CCRCC), but there is at present no study that compared these markers. We evaluated the pretreatment GPS, NLR, MLR, PLR and PNI in 430 patients, who underwent surgery for clinically localized CCRCC (pT1-3N0M0). Associations with disease-free survival were assessed with Cox models. Discrimination was measured with the C-index, and a decision curve analysis was used to evaluate the clinical net benefit. On multivariable analyses, all measures of systemic inflammatory response were significant prognostic factors. The increase in discrimination compared with the stage, size, grade and necrosis (SSIGN) score alone was 5.8 % for the GPS, 1.1-1.4 % for the NLR, 2.9-3.4 % for the MLR, 2.0-3.3 % for the PLR and 1.4-3.0 % for the PNI. On the simultaneous multivariable analysis of all candidate measures, the final multivariable model contained the SSIGN score (HR 1.40, P < 0.001), the GPS (HR 2.32, P < 0.001) and the MLR (HR 5.78, P = 0.003) as significant variables. Adding both the GPS and the MLR increased the discrimination of the SSIGN score by 6.2 % and improved the clinical net benefit. In patients with clinically localized CCRCC, the GPS and the MLR appear to be the most relevant prognostic measures of systemic inflammatory response. They may be used as an adjunct for patient counseling, tailoring management and clinical trial design.
Shroff, Geeta
2017-06-01
Stem cell therapy is a promising modality for treatment of patients with chronic cerebrovascular accident (CVA) in whom treatment other than physiotherapy or occupational therapy does not address the repair or recovery of the lost function. In this study, the author aimed at evaluating CVA patients treated with human embryonic stem cell (hESC) therapy and comparing their study outcomes with globally accepted European Stroke Scale (ESS) to that with novel scoring system, Nutech functional score (NFS), a 21-point positional and directional scoring system for assessing patients with CVA. Patients diagnosed with CVA were assessed with NFS and ESS before and after hESC therapy. NFS assessed the patients in the direction of 1-5 (bad to good), where 5 was considered as the highest possible grade (HPG). The findings were obtained for the patients who scored HPG, and had shown improvement by at least one grade. Overall, 66.7% of patients scored HPG level on the NFS scale and about 62.5% of the patients scored HPG according to the ESS scale. Approximately, 52.2% patients showed an improvement of 100% (by at least one grade) on NFS scale. None of the patients showed 100% improvement in the alteration of the score by at least one grade when scored with ESS. NFS and ESS scores show that a large population of CVA patients was benefitted with hESC therapy. NFS was found to give more convincing results than ESS, and overcomes the shortcomings of ESS.
Jones, Michael J; Neal, Christopher P; Ngu, Wee Sing; Dennison, Ashley R; Garcea, Giuseppe
2017-08-01
The aim of this study was to compare the prognostic value of established scoring systems with early warning scores in a large cohort of patients with acute pancreatitis. In patients presenting with acute pancreatitis, age, sex, American Society of Anaesthesiologists (ASA) grade, Modified Glasgow Score, Ranson criteria, APACHE II scores and early warning score (EWS) were recorded for the first 72 h following admission. These variables were compared between survivors and non-survivors, between patients with mild/moderate and severe pancreatitis (based on the 2012 Atlanta Classification) and between patients with a favourable or adverse outcome. A total of 629 patients were identified. EWS was the best predictor of adverse outcome amongst all of the assessed variables (area under curve (AUC) values 0.81, 0.84 and 0.83 for days 1, 2 and 3, respectively) and was the most accurate predictor of mortality on both days 2 and 3 (AUC values of 0.88 and 0.89, respectively). Multivariable analysis revealed that an EWS ≥2 was independently associated with severity of pancreatitis, adverse outcome and mortality. This study confirms the usefulness of EWS in predicting the outcome of acute pancreatitis. It should become the mainstay of risk stratification in patients with acute pancreatitis.
Bellini, Martina; Barbieri, Massimo
2016-01-01
Sacroiliac joint pain can be managed by intra-articular injections or radiofrequency of its innervation. Single strip lesions radiofrequency denervation is a new system. The objective of this study was to present one of the first utilizations of this innovative technique. 60 patients who met the diagnostic criteria for sacroiliac joint syndrome were enrolled in the study. In total, 102 single strip lesions radiofrequency denervations were performed. Pain intensity was measured with the Oswestry low back pain disability questionnaire and the Oswestry Disability Index whose scores were assessed at 1, 3, 6 and 12 months after the procedure. 91.8 % of the 102 radiofrequency treatments resulted in a reduction of more than 50% pain intensity relief at 1 month, 81.6% at 3 months and 59.16% at 6 months. In 35.7% of cases, the relief was continuative up to 1 year. No relief was observed in 12.24% of cases. The ODI scores improved significantly 1 month after the procedure, compared with the baseline scores. The ODI scores after 6 months improved very clearly compared with the baseline scores and with the 3-month scores. Single strip lesions radiofrequency denervation using the Simplicity III probe is a potential modality for intermediate term relief for patients with sacroiliac pain.
A real-time prediction model for post-irradiation malignant cervical lymph nodes.
Lo, W-C; Cheng, P-W; Shueng, P-W; Hsieh, C-H; Chang, Y-L; Liao, L-J
2018-04-01
To establish a real-time predictive scoring model based on sonographic characteristics for identifying malignant cervical lymph nodes (LNs) in cancer patients after neck irradiation. One-hundred forty-four irradiation-treated patients underwent ultrasonography and ultrasound-guided fine-needle aspirations (USgFNAs), and the resultant data were used to construct a real-time and computerised predictive scoring model. This scoring system was further compared with our previously proposed prediction model. A predictive scoring model, 1.35 × (L axis) + 2.03 × (S axis) + 2.27 × (margin) + 1.48 × (echogenic hilum) + 3.7, was generated by stepwise multivariate logistic regression analysis. Neck LNs were considered to be malignant when the score was ≥ 7, corresponding to a sensitivity of 85.5%, specificity of 79.4%, positive predictive value (PPV) of 82.3%, negative predictive value (NPV) of 83.1%, and overall accuracy of 82.6%. When this new model and the original model were compared, the areas under the receiver operating characteristic curve (c-statistic) were 0.89 and 0.81, respectively (P < .05). A real-time sonographic predictive scoring model was constructed to provide prompt and reliable guidance for USgFNA biopsies to manage cervical LNs after neck irradiation. © 2017 John Wiley & Sons Ltd.
Sex Differences in Vestibular/Ocular and Neurocognitive Outcomes After Sport-Related Concussion.
Sufrinko, Alicia M; Mucha, Anne; Covassin, Tracey; Marchetti, Greg; Elbin, R J; Collins, Michael W; Kontos, Anthony P
2017-03-01
To examine sex differences in vestibular and oculomotor symptoms and impairment in athletes with sport-related concussion (SRC). The secondary purpose was to replicate previously reported sex differences in total concussion symptoms, and performance on neurocognitive and balance testing. Prospective cross-sectional study of consecutively enrolled clinic patients within 21 days of a SRC. Specialty Concussion Clinic. Included male (n = 36) and female (n = 28) athletes ages 9 to 18 years. Vestibular symptoms and impairment was measured with the Vestibular/Ocular Motor Screening (VOMS). Participants completed the Immediate Post-concussion Assessment and Cognitive Test (ImPACT), Post-concussion Symptom Scale (PCSS), and Balance Error Scoring System (BESS). Sex differences on clinical measures. Females had higher PCSS scores (P = 0.01) and greater VOMS vestibular ocular reflex (VOR) score (P = 0.01) compared with males. There were no sex differences on BESS or ImPACT. Total PCSS scores together with female sex accounted for 45% of the variance in VOR scores. Findings suggest higher VOR scores after SRC in female compared with male athletes. Findings did not extend to other components of the VOMS tool suggesting that sex differences may be specific to certain types of vestibular impairment after SRC. Additional research on the clinical significance of the current findings is needed.
Food safety in food services in Lombardy: proposal for an inspection-scoring model.
Balzaretti, Claudia M; Razzini, Katia; Ziviani, Silvia; Ratti, Sabrina; Milicevic, Vesna; Chiesa, Luca M; Panseri, Sara; Castrica, Marta
2017-10-20
The purpose of this study was to elaborate a checklist with an inspection scoring system at national level in order to assess compliance with sanitary hygiene requirements of food services. The inspection scoring system was elaborated taking into account the guidelines drawn up by NYC Department of Food Safety and Mental Hygiene. Moreover the checklist was used simultaneously with the standard inspection protocol adopted by Servizio Igiene Alimenti Nutrizione ( Servizio Igiene Alimenti Nutrizione - Ss. I.A.N) and defined by D.G.R 6 March 2017 - n. X/6299 Lombardy Region. Ss. I.A.N protocol consists of a qualitative response according to which we have generated a new protocol with three different grading: A, B and C. The designed checklist was divided into 17 sections. Each section corresponds to prerequisites to be verified during the inspection. Every section includes the type of conformity to check and the type of violation: critical or general. Moreover, the failure to respect the expected compliance generates 4 severity levels that correspond to score classes. A total of 7 food services were checked with the two different inspection methods. The checklist results generated a food safety score for each food service that ranged from 0.0 (no flaws observed) to 187.2, and generates three grading class: A (0.0-28.0); B (29.0-70.0) and C (>71.00). The results from the Ss. I. A. N grading method and the checklist show positive correlation ( r =0.94, P>0.01) suggesting that the methods are comparable. Moreover, our scoring checklist is an easy and unique method compared to standard and allows also managers to perform effective surveillance programs in food service.
Food safety in food services in Lombardy: proposal for an inspection-scoring model
Balzaretti, Claudia M.; Razzini, Katia; Ziviani, Silvia; Ratti, Sabrina; Milicevic, Vesna; Chiesa, Luca M.; Panseri, Sara; Castrica, Marta
2017-01-01
The purpose of this study was to elaborate a checklist with an inspection scoring system at national level in order to assess compliance with sanitary hygiene requirements of food services. The inspection scoring system was elaborated taking into account the guidelines drawn up by NYC Department of Food Safety and Mental Hygiene. Moreover the checklist was used simultaneously with the standard inspection protocol adopted by Servizio Igiene Alimenti Nutrizione (Servizio Igiene Alimenti Nutrizione - Ss. I.A.N) and defined by D.G.R 6 March 2017 – n. X/6299 Lombardy Region. Ss. I.A.N protocol consists of a qualitative response according to which we have generated a new protocol with three different grading: A, B and C. The designed checklist was divided into 17 sections. Each section corresponds to prerequisites to be verified during the inspection. Every section includes the type of conformity to check and the type of violation: critical or general. Moreover, the failure to respect the expected compliance generates 4 severity levels that correspond to score classes. A total of 7 food services were checked with the two different inspection methods. The checklist results generated a food safety score for each food service that ranged from 0.0 (no flaws observed) to 187.2, and generates three grading class: A (0.0-28.0); B (29.0-70.0) and C (>71.00). The results from the Ss. I. A. N grading method and the checklist show positive correlation (r=0.94, P>0.01) suggesting that the methods are comparable. Moreover, our scoring checklist is an easy and unique method compared to standard and allows also managers to perform effective surveillance programs in food service. PMID:29564236
Segev, G; Langston, C; Takada, K; Kass, P H; Cowgill, L D
2016-05-01
A scoring system for outcome prediction in dogs with acute kidney injury (AKI) recently has been developed but has not been validated. The scoring system previously developed for outcome prediction will accurately predict outcome in a validation cohort of dogs with AKI managed with hemodialysis. One hundred fifteen client-owned dogs with AKI. Medical records of dogs with AKI treated by hemodialysis between 2011 and 2015 were reviewed. Dogs were included only if all variables required to calculate the final predictive score were available, and the 30-day outcome was known. A predictive score for 3 models was calculated for each dog. Logistic regression was used to evaluate the association of the final predictive score with each model's outcome. Receiver operating curve (ROC) analyses were performed to determine sensitivity and specificity for each model based on previously established cut-off values. Higher scores for each model were associated with decreased survival probability (P < .001). Based on previously established cut-off values, 3 models (models A, B, C) were associated with sensitivities/specificities of 73/75%, 71/80%, and 75/86%, respectively, and correctly classified 74-80% of the dogs. All models were simple to apply and allowed outcome prediction that closely corresponded with actual outcome in an independent cohort. As expected, accuracies were slightly lower compared with those from the previously reported cohort used initially to develop the models. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Proposal and validation of a new model to estimate survival for hepatocellular carcinoma patients.
Liu, Po-Hong; Hsu, Chia-Yang; Hsia, Cheng-Yuan; Lee, Yun-Hsuan; Huang, Yi-Hsiang; Su, Chien-Wei; Lee, Fa-Yauh; Lin, Han-Chieh; Huo, Teh-Ia
2016-08-01
The survival of hepatocellular carcinoma (HCC) patients is heterogeneous. We aim to develop and validate a simple prognostic model to estimate survival for HCC patients (MESH score). A total of 3182 patients were randomised into derivation and validation cohort. Multivariate analysis was used to identify independent predictors of survival in the derivation cohort. The validation cohort was employed to examine the prognostic capabilities. The MESH score allocated 1 point for each of the following parameters: large tumour (beyond Milan criteria), presence of vascular invasion or metastasis, Child-Turcotte-Pugh score ≥6, performance status ≥2, serum alpha-fetoprotein level ≥20 ng/ml, and serum alkaline phosphatase ≥200 IU/L, with a maximal of 6 points. In the validation cohort, significant survival differences were found across all MESH scores from 0 to 6 (all p < 0.01). The MESH system was associated with the highest homogeneity and lowest corrected Akaike information criterion compared with Barcelona Clínic Liver Cancer, Hong Kong Liver Cancer (HKLC), Cancer of the Liver Italian Program, Taipei Integrated Scoring and model to estimate survival in ambulatory HCC Patients systems. The prognostic accuracy of the MESH scores remained constant in patients with hepatitis B- or hepatitis C-related HCC. The MESH score can also discriminate survival for patients from early to advanced stages of HCC. This newly proposed simple and accurate survival model provides enhanced prognostic accuracy for HCC. The MESH system is a useful supplement to the BCLC and HKLC classification schemes in refining treatment strategies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yeo, L L L; Paliwal, P; Teoh, H L; Seet, R C; Chan, B P; Ting, E; Venketasubramanian, N; Leow, W K; Wakerley, B; Kusama, Y; Rathakrishnan, R; Sharma, V K
2015-02-01
Intracranial collaterals influence the prognosis of patients treated with intravenous tissue plasminogen activator in acute anterior circulation ischemic stroke. We compared the methods of scoring collaterals on pre-tPA brain CT angiography for predicting functional outcomes in acute anterior circulation ischemic stroke. Two hundred consecutive patients with acute anterior circulation ischemic stroke treated with IV-tPA during 2010-2012 were included. Two independent neuroradiologists evaluated intracranial collaterals by using the Miteff system, Maas system, the modified Tan scale, and the Alberta Stroke Program Early CT Score 20-point methodology. Good and extremely poor outcomes at 3 months were defined by modified Rankin Scale scores of 0-1 and 5-6 points, respectively. Factors associated with good outcome on univariable analysis were younger age, female sex, hypertension, diabetes mellitus, atrial fibrillation, small infarct core (ASPECTS ≥8), vessel recanalization, lower pre-tPA NIHSS scores, and good collaterals according to Tan methodology, ASPECTS methodology, and Miteff methodology. On multivariable logistic regression, only lower NIHSS scores (OR, 1.186 per point; 95% CI, 1.079-1.302; P = .001), recanalization (OR, 5.599; 95% CI, 1.560-20.010; P = .008), and good collaterals by the Miteff method (OR, 3.341; 95% CI, 1.203-5.099; P = .014) were independent predictors of good outcome. Poor collaterals by the Miteff system (OR, 2.592; 95% CI, 1.113-6.038; P = .027), Maas system (OR, 2.580; 95% CI, 1.075-6.187; P = .034), and ASPECTS method ≤5 points (OR, 2.685; 95% CI, 1.156-6.237; P = .022) were independent predictors of extremely poor outcomes. Only the Miteff scoring system for intracranial collaterals is reliable for predicting favorable outcome in thrombolyzed acute anterior circulation ischemic stroke. However, poor outcomes can be predicted by most of the existing methods of scoring intracranial collaterals. © 2015 by American Journal of Neuroradiology.
A Comparison of Systemic Inflammation-Based Prognostic Scores in Patients on Regular Hemodialysis
Kato, Akihiko; Tsuji, Takayuki; Sakao, Yukitoshi; Ohashi, Naro; Yasuda, Hideo; Fujimoto, Taiki; Takita, Takako; Furuhashi, Mitsuyoshi; Kumagai, Hiromichi
2013-01-01
Background/Aims Systemic inflammation-based prognostic scores have prognostic power in patients with cancer, independently of tumor stage and site. Although inflammatory status is associated with mortality in hemodialysis (HD) patients, it remains to be determined as to whether these composite scores are useful in predicting clinical outcomes. Methods We calculated the 6 prognostic scores [Glasgow prognostic score (GPS), modified GPS (mGPS), neutrophil-lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), prognostic index (PI) and prognostic nutritional index (PNI), which have been established as a useful scoring system in cancer patients. We enrolled 339 patients on regular HD (age: 64 ± 13 years; time on HD: 129 ± 114 months; males/females = 253/85) and followed them for 42 months. The area under the receiver-operating characteristics curve was used to determine which scoring system was more predictive of mortality. Results Elevated GPS, mGPS, NLR, PLR, PI and PNI were all associated with total mortality, independent of covariates. If GPS was raised, mGPS, NLR, PLR and PI were also predictive of all-cause mortality and/or hospitalization. GPS and PNI were associated with poor nutritional status. Using overall mortality as an endpoint, the area under the curve (AUC) was significant for a GPS of 0.701 (95% CI: 0.637-0.765; p < 0.01) and for a PNI of 0.616 (95% CI: 0.553-0.768; p = 0.01). However, AUC for hypoalbuminemia (<3.5 g/dl) was comparable to that of GPS (0.695, 95% CI: 0.632-0.759; p < 0.01). Conclusion GPS, based on serum albumin and highly sensitive C-reactive protein, has the most prognostic power for mortality prediction among the prognostic scores in HD patients. However, as the determination of serum albumin reflects mortality similarly to GPS, other composite combinations are needed to provide additional clinical utility beyond that of albumin alone in HD patients. PMID:24403910
Wang, Miao; Bünger, Cody Eric; Li, Haisheng; Wu, Chunsen; Høy, Kristian; Niedermann, Bent; Helmig, Peter; Wang, Yu; Jensen, Anders Bonde; Schättiger, Katrin; Hansen, Ebbe Stender
2012-04-01
We conducted a prospective cohort study of 448 patients with spinal metastases from a variety of cancer groups. To determine the specific predictive value of the Tokuhashi scoring system (T12) and its revised version (T15) in spinal metastases of various primary tumors. The life expectancy of patients with spinal metastases is one of the most important factors in selecting the treatment modality. Tokuhashi et al formulated a prognostic scoring system with a total sum of 12 points for preoperative prediction of life expectancy in 1990 and revised it in 2005 to a total sum of 15 points. There is a lack of knowledge about the specific predictive value of those scoring systems in patients with spinal metastases from a variety of cancer groups. We included 448 patients with vertebral metastases who underwent surgical treatment during November 1992 to November 2009 in Aarhus University Hospital NBG. Data were retrieved from Aarhus Metastases Database. Scores based on T12 and T15 were calculated prospectively for each patient. We divided all the patients into different groups dictated by the site of their primary tumor. Predictive value and accuracy rate of the 2 scoring systems were compared in each cancer group. Both the T12 and T15 scoring systems showed statistically significant predictive value when the 448 patients were analyzed in total (T12, P < 0.0001; T15, P < 0.0001). The accuracy rate was significantly higher in T15 (P < 0.0001) than in T12. The further analyses by primary cancer groups showed that the predictive value of T12 and T15 was primarily determined by the prostate (P = 0.0003) and breast group (P = 0.0385). Only T12 displayed predictive value in the colon group (P = 0.0011). Neither of the scoring systems showed significant predictive value in the lung (P > 0.05), renal (P > 0.05), or miscellaneous primary tumor groups (P > 0.05). The accuracy rate of prognosis in T15 was significantly improved in the prostate (P = 0.0032) and breast group (P < 0.0001). Both T12 and T15 showed significant predictive value in patients with spinal metastases. T15 has a statistically higher accuracy rate than T12. Among the various cancer groups, the 2 scoring systems are especially reliable in prostate and breast metastases groups. T15 is recommended as superior to T12 because of its higher accuracy rate.
Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir
2013-01-01
The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males < 50 yrs were significantly overrepresented when compared with the non-AB groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.
Kloeckner, Roman; Pitton, Michael B; Dueber, Christoph; Schmidtmann, Irene; Galle, Peter R; Koch, Sandra; Wörns, Marcus A; Weinmann, Arndt
2017-01-01
To perform an external validation of the Assessment for Retreatment with Transarterial Chemoembolization (ART) and α-fetoprotein (AFP), Barcelona Clinic Liver Cancer (BCLC), Child-Pugh, and response (ABCR) scores and to compare them in terms of prognostic power. From 2000 to 2015, 871 patients with hepatocellular carcinoma underwent transarterial chemoembolization at a tertiary referral hospital, and 176 met all inclusion and exclusion criteria for both scores and were analyzed. Nineteen percent (n = 34) had BCLC stage A disease and 81% had stage B disease. Thirty-nine patients (22%) presented with elevated AFP levels. Overall survival was calculated. Scores were validated and compared with a Harrell C-index, integrated Brier score (IBS), and prediction error curves. Before the second chemoembolization procedure, 22 patients (12%) showed an increase of 1 point in Child-Pugh score and 51 patients (22%) had an increase of ≥ 2 points. Thirty-one patients (23%) showed a > 25% increase in aspartate aminotransferase level, and 114 (65%) showed a response to treatment. Consequently, 127 patients (72%) had a low ART score and 49 (28%) had a high ART score. One hundred fifty-eight patients (90%) had a low ABCR score, whereas 18 (10%) had a high ABCR score. Low and high ART score groups had median survival durations of 20.8 and 15.3 mo, respectively. Harrell C-indexes were 0.572 and 0.608, and IBSs were 0.135 and 0.128, for ART and ABCR, respectively. For both scores, an increase in Child-Pugh score ≥ 2 points and a radiologic response were significantly associated with survival. Both scores were of limited predictive value, and neither was sufficient to support clear-cut clinical decisions. Further effort is necessary to determine criteria for making valid clinical predictions. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T
2017-12-28
The objective of this study was to evaluate the influence of iterative reconstruction on coronary calcium scores (CCS) at different heart rates for four state-of-the-art CT systems. Within an anthropomorphic chest phantom, artificial coronary arteries were translated in a water-filled compartment. The arteries contained three different calcifications with low (38 mg), medium (80 mg) and high (157 mg) mass. Linear velocities were applied, corresponding to heart rates of 0, < 60, 60-75 and > 75 bpm. Data were acquired on four state-of-the-art CT systems (CT1-CT4) with routinely used CCS protocols. Filtered back projection (FBP) and three increasing levels of iterative reconstruction (L1-L3) were used for reconstruction. CCS were quantified as Agatston score and mass score. An iterative reconstruction susceptibility (IRS) index was used to assess susceptibility of Agatston score (IRS AS ) and mass score (IRS MS ) to iterative reconstruction. IRS values were compared between CT systems and between calcification masses. For each heart rate, differences in CCS of iterative reconstructed images were evaluated with CCS of FBP images as reference, and indicated as small (< 5%), medium (5-10%) or large (> 10%). Statistical analysis was performed with repeated measures ANOVA tests. While subtle differences were found for Agatston scores of low mass calcification, medium and high mass calcifications showed increased CCS up to 77% with increasing heart rates. IRS AS of CT1-T4 were 17, 41, 130 and 22% higher than IRS MS . Not only were IRS significantly different between all CT systems, but also between calcification masses. Up to a fourfold increase in IRS was found for the low mass calcification in comparison with the high mass calcification. With increasing iterative reconstruction strength, maximum decreases of 21 and 13% for Agatston and mass score were found. In total, 21 large differences between Agatston scores from FBP and iterative reconstruction were found, while only five large differences were found between FBP and iterative reconstruction mass scores. Iterative reconstruction results in reduced CCS. The effect of iterative reconstruction on CCS is more prominent with low-density calcifications, high heart rates and increasing iterative reconstruction strength.
FOUR Score Predicts Early Outcome in Patients After Traumatic Brain Injury.
Nyam, Tee-Tau Eric; Ao, Kam-Hou; Hung, Shu-Yu; Shen, Mei-Li; Yu, Tzu-Chieh; Kuo, Jinn-Rung
2017-04-01
The aim of the study was to determine whether the Full Outline of UnResponsiveness (FOUR) score, which includes eyes opening (E), motor function (M), brainstem reflex (B), and respiratory pattern (R), can be used as an alternate method to the Glasgow Coma Scale (GCS) in predicting intensive care unit (ICU) mortality in traumatic brain injury (TBI) patients. From January 2015 to June 2015, patients with isolated TBI admitted to the ICU were enrolled. Three advanced practice nurses administered the FOUR score, GCS, Acute Physiology and Chronic Health Evaluation II (APACHE II), and Therapeutic Intervention Scoring System (TISS) concurrently from ICU admissions. The endpoint of observation was mortality when the patients left the ICU. Data are presented as frequency with percentages, mean with standard deviation, or median with interquartile range. Each measurement tool used area under the receiver operating characteristic curve to compare the predictive power between these four tools. In addition, the difference between survival and death was estimated using the Wilcoxon rank sum test. From 55 TBI patients, males (72.73 %) were represented more than females, the mean age was 63.1 ± 17.9, and 19 of 55 observations (35 %) had a maximum FOUR score of 16. The overall mortality rate was 14.6 %. The area under the receiver operating characteristic curve was 74.47 % for the FOUR score, 74.73 % for the GCS, 81.78 % for the APACHE II, and 53.32 % for the TISS. The FOUR score has similar predictive power of mortality compared to the GCS and APACHE II. Each of the parameters-E, M, B, and R-of the FOUR score showed a significant difference between mortality and survival group, while the verbal and eye-opening components of the GCS did not. Having similar predictive power of mortality compared to the GCS and APACHE II, the FOUR score can be used as an alternative in the prediction of early mortality in TBI patients in the ICU.
Paunic, Teodora; Parojcic, Aleksandra; Savic-Pavicevic, Dusanka; Vujnic, Milorad; Pesovic, Jovan; Basta, Ivana; Lavrnic, Dragana; Rakocevic-Stojanovic, Vidosava
2017-01-01
Myotonic dystrophy type 2 (DM2) is a multisystem disorder that affects many organs and systems, including the brain. The objective is to analyze personality patterns in myotonic dystrophy type 2 (DM2) compared to DM1 control group. The study comprised 27 consecutive genetically confirmed DM2 patients and control group of 44 DM1 patients. Personality traits were assessed with the Millon Multiaxial Clinical Inventory III (MMCI III). In DM2 group there were no scale with pathological scores, although compulsive and paranoid traits were the most prominent. DM2 patients had lower scores compared to DM1 patients in almost all scales. Pathological scores on clinical symptom scales were not observed, although anxiety scale almost approached this value. Patients with higher compulsive score had higher level of education (rho = +0.53, p < 0.01). On the other hand, higher paranoid score correlated with younger age at onset (rho = -0.34, p < 0.01) and lower educational level (rho = -0.26, p < 0.05). Our results did not show significant personality impairments in patients with DM2. However, following personality traits were predominant: compulsive (in patients with higher education) and paranoid (in patients with lower education and earlier age at onset). The most common clinical symptoms were anxiety and somatization. PMID:28690389
Tsigginou, Alexandra; Gkali, Christina; Chalazonitis, Athanasios; Feida, Eleni; Vlachos, Dimitrios Efthymios; Zagouri, Flora; Rellias, Ioannis; Dimitrakakis, Constantine
2016-11-01
Dual-energy contrast-enhanced spectral mammography (CESM) represents a relatively new diagnostic tool adjunct to mammography. The aim of this study was to strengthen the breast imaging-reporting and data system (BIRADS) classification score in order to improve early breast cancer diagnosis. For this reason, we propose a sum score, termed malignancy potential score (MPS), incorporating the standard BIRADS score and our proposed CESM score. From September 2014 to September 2015, 216 females (age range, 26-85 years; mean age 54.6 years) underwent CESM evaluation of mammographic findings that were primarily assessed as BIRADS 2-5. 10 of these patients had bilateral findings; a total of 226 lesions were examined. High-energy image evaluation was based on the intensity of contrast enhancement of the lesion compared with background enhancement, categorized as Type -1, 0, 1 or 2 enhancement. Histopathology reports were compared with imaging assessment. 98 of 226 lesions were malignant and 128 of 226 lesions were benign. The area under the curve was 0.843, 0.888 and 0.917 for mammographic BIRADS score, CESM score and MPS, respectively, with p-value < 0.05. The sensitivity, specificity and accuracy rates were 91.83, 80.47 and 85.40%, respectively, when a best MPS cut-off point of 4 was used. The malignancy potential score (MPS) has higher diagnostic performance than digital mammography or CESM alone. MPS empowers the credibility of the digital mammography BIRADS score and our proposed type of enhancement in dual-energy CESM and is a diagnostic tool that increases the accuracy rate in early breast cancer diagnosis.
Jeffery, Dean; Buller, M; Wichuk, Stephanie; McDougall, Dave; Lambert, Robert GW; Maksymowych, Walter P
2017-01-01
Objective Bone marrow lesions (BML) are an MRI feature of osteoarthritis (OA) offering a potential target for therapy. We developed the Knee Inflammation MRI Scoring System (KIMRISS) to semiquantitatively score BML with high sensitivity to small changes, and compared feasibility, reliability and responsiveness versus the established MRI Osteoarthritis Knee Score (MOAKS). Methods KIMRISS incorporates a web-based graphic overlay to facilitate detailed regional BML scoring. Observers scored BML by MOAKS and KIMRISS on sagittal fluid-sensitive sequences. Exercise 1 focused on interobserver reliability in Osteoarthritis Initiative observational data, with 4 readers (two experienced/two new to KIMRISS) scoring BML in 80 patients (baseline/1 year). Exercise 2 focused on responsiveness in an open-label trial of adalimumab, with 2 experienced readers scoring BML in 16 patients (baseline/12 weeks). Results Scoring time was similar for KIMRISS and MOAKS. Interobserver reliability of KIMRISS was equivalent to MOAKS for BML status (ICC=0.84 vs 0.79), but consistently better than MOAKS for change in BML: Exercise 1 (ICC 0.82 vs 0.53), Exercise 2 (ICC 0.90 vs 0.32), and in new readers (0.87–0.92 vs 0.32–0.51). KIMRISS BML was more responsive than MOAKS BML: post-treatment BML improvement in Exercise 2 reached statistical significance for KIMRISS (SRM −0.69, p=0.015), but not MOAKS (SRM −0.12, p=0.625). KIMRISS BML also more strongly correlated to WOMAC scores than MOAKS BML (r=0.80 vs 0.58, p<0.05). Conclusions KIMRISS BML scoring was highly feasible, and was more reliable for assessment of change and more responsive to change than MOAKS BML for expert and new readers. PMID:28123780
Preliminary report of the Hepatic Encephalopathy Assessment Driving Simulator (HEADS) score.
Baskin-Bey, Edwina S; Stewart, Charmaine A; Mitchell, Mary M; Bida, John P; Rosenthal, Theodore J; Nyberg, Scott L
2008-01-01
Audiovisual simulations of real-life driving (ie, driving simulators) have been used to assess neurologic dysfunction in a variety of medical applications. However, the use of simulated driving to assess neurologic impairment in the setting of liver disease (ie, hepatic encephalopathy) is limited. The aim of this analysis was to develop a scoring system based on simulated driving performance to assess mild cognitive impairment in cirrhotic patients with hepatic encephalopathy. This preliminary analysis was conducted as part of the Hepatic Encephalopathy Assessment Driving Simulator (HEADS) pilot study. Cirrhotic volunteers initially underwent a battery of neuropsychological tests to identify those cirrhotic patients with mild cognitive impairment. Performance during an audiovisually simulated course of on-road driving was then compared between mildly impaired cirrhotic patients and healthy volunteers. A scoring system was developed to quantify the likelihood of cognitive impairment on the basis of data from the simulated on-road driving. Mildly impaired cirrhotic patients performed below the level of healthy volunteers on the driving simulator. Univariate logistic regression and correlation models indicated that several driving simulator variables were significant predictors of cognitive impairment. Five variables (run time, total map performance, number of collisions, visual divided attention response, and average lane position) were incorporated into a quantitative model, the HEADS scoring system. The HEADS score (0-9 points) showed a strong correlation with cognitive impairment as measured by area under the receiver-operator curve (.89). The HEADS system appears to be a promising new tool for the assessment of mild hepatic encephalopathy.
Scoring Methods in the International Land Benchmarking (ILAMB) Package
NASA Astrophysics Data System (ADS)
Collier, N.; Hoffman, F. M.; Keppel-Aleks, G.; Lawrence, D. M.; Mu, M.; Riley, W. J.; Randerson, J. T.
2017-12-01
The International Land Model Benchmarking (ILAMB) project is a model-data intercomparison and integration project designed to improve the performance of the land component of Earth system models. This effort is disseminated in the form of a python package which is openly developed (https://bitbucket.org/ncollier/ilamb). ILAMB is more than a workflow system that automates the generation of common scalars and plot comparisons to observational data. We aim to provide scientists and model developers with a tool to gain insight into model behavior. Thus, a salient feature of the ILAMB package is our synthesis methodology, which provides users with a high-level understanding of model performance. Within ILAMB, we calculate a non-dimensional score of a model's performance in a given dimension of the physics, chemistry, or biology with respect to an observational dataset. For example, we compare the Fluxnet-MTE Gross Primary Productivity (GPP) product against model output in the corresponding historical period. We compute common statistics such as the bias, root mean squared error, phase shift, and spatial distribution. We take these measures and find relative errors by normalizing the values, and then use the exponential to map this relative error to the unit interval. This allows for the scores to be combined into an overall score representing multiple aspects of model performance. In this presentation we give details of this process as well as a proposal for tuning the exponential mapping to make scores more cross comparable. However, as many models are calibrated using these scalar measures with respect to observational datasets, we also score the relationships among relevant variables in the model. For example, in the case of GPP, we also consider its relationship to precipitation, evapotranspiration, and temperature. We do this by creating a mean response curve and a two-dimensional distribution based on the observational data and model results. The response curves are then scored using a relative measure of the root mean squared error and the exponential as before. The distributions are scored using the so-called Hellinger distance, a statistical measure for how well one distribution is represented by another, and included in the model's overall score.
Beese, Mark E; Joy, Elizabeth; Switzler, Craig L; Hicks-Little, Charlie A
2015-08-01
Single-sport specialization (SSS) is becoming more prevalent in youth athletes. Deficits in functional movement have been shown to predispose athletes to injury. It is unclear whether a link exists between SSS and the development of functional movement deficits that predispose SSS athletes to an increased risk of knee injury. To determine whether functional movement deficits exist in SSS athletes compared with multi-sport (M-S) athletes. Cross-sectional study. Soccer practice fields. A total of 40 (21 SSS [age = 15.05 ± 1.2 years], 19 M-S [age = 15.32 ± 1.2 years]) female high school athlete volunteers were recruited through local soccer clubs. All SSS athletes played soccer. Participants were grouped into 2 categories: SSS and M-S. All participants completed 3 trials of the standard Landing Error Scoring System (LESS) jump-landing task. They performed a double-legged jump from a 30-cm platform, landing on a rubber mat at a distance of half their body height. Upon landing, participants immediately performed a maximal vertical jump. Values were assigned to each trial using the LESS scoring criteria. We averaged the 3 scored trials and then used a Mann-Whitney U test to test for differences between groups. Participant scores from the jump-landing assessment for each group were also placed into the 4 defined LESS categories for group comparison using a Pearson χ(2) test. The α level was set a priori at .05. Mean scores were 6.84 ± 1.81 for the SSS group and 6.07 ± 1.93 for the M-S group. We observed no differences between groups (z = -1.44, P = .15). A Pearson χ(2) analysis revealed that the proportions of athletes classified as having excellent, good, moderate, or poor LESS scores were not different between the SSS and M-S groups ([Formula: see text] = 1.999, P = .57). Participation in soccer alone compared with multiple sports did not affect LESS scores in adolescent female soccer players. However, the LESS scores indicated that most female adolescent athletes may be at an increased risk for knee injury, regardless of the number of sports played.
Tarfarosh, Shah Faisal Ahmad; Lone, Baseer-Ul-Rasool; Beigh, Mirza-Idrees-Ul-Haq; Manzoor, Mushbiq
2016-06-29
We developed a portable multimodal system with seven different mechanisms of pain relief incorporated into a lumbar belt called the Comfort-N-Harmony Belt (C&H belt). Here, we describe the technical details of the system and also summarize the effects of this multimodal pain relieving technology as an adjuvant to analgesics versus analgesics alone, on the level of pain, improvement of psychological status, disability, and the quality of life in the patients with neuropathic low back pain (LBP). We tracked the volunteers who were following up at a tertiary health care center for the complaints of neuropathic LBP of minimum three months duration and were on analgesics alone with no relief in the severity of the pain. Study group A (n = 45) consisted of volunteers with LBP on C&H belt therapy, along with the usually prescribed analgesic intake, and group B (n = 45) with LBP volunteers on analgesics, plus a similar looking but plain leather belt (placebo). For pain, the VAS (Visual Analogue Scale); for anxiety and depression, the (HADS) Hospital Anxiety-Depression Scale; for disability, the RMDQ (Roland Morris Disability Questionnaire); and for quality of life, (NHP) Nottingham-Health-Profile were used before and after the study period. There were no significant differences in demographic variables between the groups (p < 0.05). After the study period of one month, VAS, RMDQ, NHP-pain, NHP-physical activity, and HADS scores in both groups were significantly improved compared to the pre-treatment scores (p < 0.05). Group A also showed significant improvements in the scores of NHP-energy level and NHP-social isolation (p < 0.05). The post-treatment scores did not significantly show any difference between the two groups (p > 0.05). However, in comparison of pre- and post-treatment scores, the pre-treatment score values of RMDQ, NHP-pain, NHP-physical activity, and NHP-social isolation were much higher in group A compared to the group B, but still these scores were, in a statistically significant manner, improved in group A compared to the group B after the study period was over (p < 0.05). Multiple pain relieving mechanisms in a portable device-based system, when used along with analgesics, are effective in relieving pain, improving function and quality of life, and help in relieving the associated anxiety and depression in patients with chronic neuropathic LBP than the analgesics alone in the Kashmiri (Southeast Asian) population.
Farley, Donna O; Elliott, Marc N; Haviland, Amelia M; Slaughter, Mary Ellen; Heller, Amy
2011-01-01
Objective To understand reasons why California has lower Consumer Assessment of Healthcare Providers and Systems (CAHPS) scores than the rest of the country, including differing patterns of CAHPS scores between Medicare Advantage (MA) and fee-for-service, effects of additional demographic characteristics of beneficiaries, and variation across MA plans within California. Study Design/Data Collection Using 2008 CAHPS survey data for fee-for-service Medicare beneficiaries and MA members, we compared mean case mix adjusted Medicare CAHPS scores for California and the remainder of the nation. Principal Findings California fee-for-service Medicare had lower scores than non-California fee-for-service on 11 of 14 CAHPS measures; California MA had lower scores only for physician services measures and higher scores for other measures. Adding race/ethnicity and urbanity to risk adjustment improved California standing for all measures in both MA and fee-for-service. Within the MA plans, one large plan accounted for the positive performance in California MA; other California plans performed below national averages. Conclusions This study shows that the mix of fee-for-service and MA enrollees, demographic characteristics of populations, and plan-specific factors can all play a role in observed regional variations. Anticipating value-based payments, further study of successful MA plans could generate lessons for enhancing patient experience for the Medicare population. PMID:21644970
Kayser, Cristiane; Sekiyama, Juliana Y; Próspero, Lucas C; Camargo, Cintia Z; Andrade, Luis E C
2013-01-01
Peripheral microangiopathy is a hallmark of systemic sclerosis (SSc) and can be early detected by nailfold capillaroscopy (NFC). This study aimed to examine whether more severe peripheral microangiopathy at NFC are predictive factor for death in SSc patients. 135 SSc patients who performed NFC between June 2001 and July 2009 were included. The following NFC parameters were evaluated: number of capillary loops/mm, avascular score (scored from 0 to 3), and number of enlarged and giant capillary loops. Univariate and multivariate regression models were used to analyse the association of mortality with NFC and clinical parameters. At the time of the analysis (August 2010), 123 patients were alive, and 12 were dead. By univariate analysis, male gender, forced vital capacity <75% predicted, higher number of giant capillary loops, and an avascular score >1.5 on NFC were associated with a significantly increase risk of death. By multivariate analysis, an avascular score >1.5 was the only independent predictor of death (hazard ratio 2.265). Survival rates from diagnosis at 1, 5 and 10 years were lower in patients with avascular score >1.5 (97%, 86%, and 59%, respectively) compared with those with avascular score ≤1.5 (97%, 97%, and 91% respectively) (p=0.009 by log rank test). Avascular scores higher than 1.5 at NFC was an independent predictor of death in SSc, suggesting that NFC can be useful for predicting SSc outcome.
COMPLICATIONS AMONG COLORECTAL CANCER SURVIVORS: SF-6D PREFERENCE-WEIGHTED QUALITY OF LIFE SCORES
Hornbrook, Mark C.; Wendel, Christopher S.; Coons, Stephen Joel; Grant, Marcia; Herrinton, Lisa J.; Mohler, M. Jane; Baldwin, Carol M.; McMullen, Carmit K.; Green, Sylvan B.; Alschuler, Andrea; Rawl, Susan M.; Krouse, Robert S.
2012-01-01
Background Societal preference-weighted health-related quality of life (HRQOL) scores enable comparing multi-dimensional health states across diseases and treatments for research and policy. Objective To assess the effects of living with a permanent intestinal stoma, compared to a major bowel resection, among colorectal cancer (CRC) survivors. Research Design Cross-sectional multivariate linear regression analysis to explain preference-weighted HRQOL scores. Subjects Six-hundred-forty CRC survivors (≥5 years) from three group-model HMOs; ostomates and non-ostomates with colorectal resections for CRC were matched on gender, age (±5 years), time since diagnosis, and tumor site (rectum vs. colon). Measures SF-6D scoring system applied to Medical Outcomes Study Short Form-36 version 2 (SF-36v2); City of Hope Quality of Life-Ostomy (mCOH-QOL-O); Charlson-Deyo comorbidity index. Methods Survey of CRC survivors linked to respondents’ clinical data extracted from HMO files. Results Response rate was 52%. Ostomates and non-ostomates had similar sociodemographic characteristics. Mean SF-6D score was 0.69 for ostomates, compared to 0.73 for non-ostomates (p <.001), but other factors explained this difference. Complications of initial cancer surgery, and prior-year comorbidity burden and hospital use were negatively associated with SF-6D scores, while household income was positively associated. Conclusions CRC survivors’ SF-6D scores were not associated with living with a permanent ostomy after other factors were taken into account. Surgical complications, comorbidities, and metastatic disease lowered the preference-weighted HRQOL of CRC survivors with and without ostomies. Further research to understand and reduce late complications from CRC surgeries as well as associated depression is warranted. PMID:21224741
ERIC Educational Resources Information Center
Jonas, Peter M.; Weimer, Don
This two-year study involving five colleges and universities compared the academic achievement, as measured by the Educational Testing Service (ETS) Major Field Achievement Test (MFAT) in Business of students in traditional undergraduate programs and those in non-traditional accelerated adult degree programs. The study also compared the subjects'…
The Impact of a Flexible Assessment System on Students' Motivation, Performance and Attitude
ERIC Educational Resources Information Center
Pacharn, Parunchana; Bay, Darlene; Felton, Sandra
2013-01-01
We examine a flexible assessment system that allows students to determine the weights allocated to each course component and to re-allocate the weights in response to achieved scores. The flexibility is intended to encourage students' participation in the learning process, thereby promoting self-regulated learning skills. We compare this…
Ayad, Essam; Mansy, Mina; Elwi, Dalal; Salem, Mostafa; Salama, Mohamed; Kayser, Klaus
2015-01-01
Optimization of workflow for breast cancer samples with equivocal human epidermal growth factor receptors 2 (HER2)/neu score 2(+) results in routine practice, remains to be a central focus of the on-going efforts to assess HER2 status. According to the College of American Pathologists/American Society of Clinical Oncology guidelines equivocal HER2/neu score 2(+) cases are subject for further testing, usually by fluorescence in situ hybridization (FISH) investigations. It still remains on open question, whether quantitative digital image analysis of HER2 immunohistochemistry (IHC) stained slides can assist in further refining the HER2 score 2(+). To assess utility of quantitative digital analysis of IHC stained slides and compare its performance to FISH in cases of breast cancer with equivocal HER2 score 2(+). Fifteen specimens (previously diagnosed as breast cancer and was evaluated as HER 2(-) score 2(+)) represented the study population. Contemporary new cuts were prepared for re-evaluation of HER2 immunohistochemical studies and FISH examination. All the cases were digitally scanned by iScan (Produced by BioImagene [Now Roche-Ventana]). The IHC signals of HER2 were measured using an automated image analyzing system (MECES, www.Diagnomx.eu/meces). Finally, a comparative study was done between the results of the FISH and the quantitative analysis of the virtual slides. Three out of the 15 cases with equivocal HER2 score 2(+), turned out to be positive (3(+)) by quantitative digital analysis, and 12 were found to be negative in FISH too. Two of these three positive cases proved to be positive with FISH, and only one was negative. Quantitative digital analysis is highly sensitive and relatively specific when compared to FISH in detecting HER2/neu overexpression. Therefore, it represents a potential reliable substitute for FISH in breast cancer cases, which desire further refinement of equivocal IHC results.
Lin, Jin-Xiang; Fan, Zu-Yan; Lin, Qu; Wu, Dong-Hao; Wu, Xiang-Yuan; Chen, Yan-Ru; Fang, Heng-Ying; Wu, Dong-Bing; Wen, Jing-Yun; Dong, Min; Ma, Xiao-Kun; Wan, Xiang-Bo
2015-04-01
To compare the efficacy of dioctahedral smectite and iodine glycerin (DSIG) cream with topical mouth rinse (composed of saline, gentamicin and Vitamin B12) in treatment of chemotherapy induced oral mucositis (OM). A total of 130 intensive chemotherapy or stem cells transplantation induced OM patients were recruited. Among these patients, 67 patients received topical mouth rinse and 63 patients received DSIG cream treatment. The OM would be treated on the OM appearance and sustained for 5 days. OM severity was measured daily using The American Oncology Nursing Society recommended Oral Assessment Guideline (OAG) score system. Compared with topical mouth rinse treatment, a significant lower OAG score was observed in DSIG cream treated patients. Specifically, the OAG scores were respectively 12.1 ± 1.1, 12.0 ± 1.2, 11.3 ± 1.3 and 10.4 ± 1.3 from day 2 to day 5 in topical mouth rinse treatment subgroup. Correspondingly, the OAG scores were respectively 10.2 ± 1.0, 9.3 ± 0.9, 8.5 ± 0.6 and 8.0 ± 0.2 for DSIG cream treatment subset (all P < 0.05). Importantly, compared with topical mouth rinse treatment, the DSIG cream significantly shortened OM repair time (4.68 ± 0.98 vs. 8.76 ± 1.80 days, P < 0.001). After 5 days treatment, 54 patients (85.7%) obtained complete regression with an OAG score ≤8, and 7 patients (11.1%) had partial regression with an OAG score of 9-10 in DSIG cream treatment subgroup. However, only 2 patients (3.0%) obtained completed regression and 32 patients (47.8%) had partial regression in topical mouth rinse treatment cohort. Moreover, no serious side-effect was observed in both cohorts. Compared with topical mouth rinse, DSIG cream significantly lowered the OAG score and shortened OM duration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chigerwe, Munashe; Boudreaux, Karen A; Ilkiw, Jan E
2014-11-28
Burnout among veterinary students can result from known stressors in the absence of a support system. The objectives of this study were to evaluate use of the Maslach Burnout Inventory-Educator Survey (MBI-ES) to assess burnout in veterinary students and evaluate the factors that predict the MBI-ES scores. The MBI-ES was administered to first (Class of 2016) and second year (Class of 2015) veterinary medical students during the 2012-2013 academic year in the fall and spring semesters. Factor analysis and test reliability for the survey were determined. Mean scores for the subscales determining burnout namely emotional exhaustion (EE), depersonalization (DP) and lack of personal accomplishment (PA) were calculated for both classes in the 2 semesters. Multiple regression analysis was performed to evaluate other factors that predict the MBI-ES scores. A non-probability sampling method was implemented consisting of a voluntary sample of 170 and 123 students in the fall and spring semesters, respectively. Scores for EE, DP and PA were not different between the 2 classes within the same semester. Mean ± SD scores for EE, DP and PA for the fall semester were 22.9 ± 9.6, 5.0 ± 4.8 and 32.3 ± 6.7, respectively. Mean ± SD scores for EE, DP and PA the spring semester were 27.8 ± 10.7, 6.5 ± 6.1and 31.7 ± 6.8, respectively. The EE score was higher in spring compared to fall while DP and PA scores were not different between the 2 semesters. Living arrangements specifically as to whether or not a student lived with another veterinary medical students was the only variable significantly associated with the MBI-ES scores. Students in this study had moderate levels of burnout based on the MBI-ES scores. The MBI-ES was an acceptable instrument for assessing burnout in veterinary medical students. The EE scores were higher in the spring semester as compared to the fall semester. Thus students in the first and second years of veterinary school under the current curriculum experience the greatest levels of emotional exhaustion during the spring semester. This has administrative implications for the school, when considering the allocation and use of resources for student support systems during each semester.
2010-01-01
Introduction The Glasgow Coma Scale (GCS) is the most widely used scoring system for comatose patients in intensive care. Limitations of the GCS include the impossibility to assess the verbal score in intubated or aphasic patients, and an inconsistent inter-rater reliability. The FOUR (Full Outline of UnResponsiveness) score, a new coma scale not reliant on verbal response, was recently proposed. The aim of the present study was to compare the inter-rater reliability of the GCS and the FOUR score among unselected patients in general critical care. A further aim was to compare the inter-rater reliability of neurologists with that of intensive care unit (ICU) staff. Methods In this prospective observational study, scoring of GCS and FOUR score was performed by neurologists and ICU staff on 267 consecutive patients admitted to intensive care. Results In a total of 437 pair wise ratings the exact inter-rater agreement for the GCS was 71%, and for the FOUR score 82% (P = 0.0016); the inter-rater agreement within a range of ± 1 score point for the GCS was 90%, and for the FOUR score 92% (P = ns.). The exact inter-rater agreement among neurologists was superior to that among ICU staff for the FOUR score (87% vs. 79%, P = 0.04) but not for the GCS (73% vs. 73%). Neurologists and ICU staff did not significantly differ in the inter-rater agreement within a range of ± 1 score point for both GCS (88% vs. 93%) and the FOUR score (91% vs. 88%). Conclusions The FOUR score performed better than the GCS for exact inter-rater agreement, but not for the clinically more relevant agreement within the range of ± 1 score point. Though neurologists outperformed ICU staff with regard to exact inter-rater agreement, the inter-rater agreement of ICU staff within the clinically more relevant range of ± 1 score point equalled that of the neurologists. The small advantage in inter-rater reliability of the FOUR score is most likely insufficient to replace the GCS, a score with a long tradition in intensive care. PMID:20398274
2016-12-22
included assessments and instruments, descriptive statistics were calculated. Independent-samples t-tests were conducted using participant survey scores...integrity tests within a multimodal system. Both conditions included the Military Acute Concussion Evaluation (MACE) and an Ease-of-Use survey . Mean scores...for the Ease-of-Use survey and mean test administration times for each measure were compared. Administrative feedback was also considered for
Chughtai, Abrar Ahmad; MacIntyre, C. Raina
2017-01-01
Abstract The 2014 Ebola virus disease (EVD) outbreak affected several countries worldwide, including six West African countries. It was the largest Ebola epidemic in the history and the first to affect multiple countries simultaneously. Significant national and international delay in response to the epidemic resulted in 28,652 cases and 11,325 deaths. The aim of this study was to develop a risk analysis framework to prioritize rapid response for situations of high risk. Based on findings from the literature, sociodemographic features of the affected countries, and documented epidemic data, a risk scoring framework using 18 criteria was developed. The framework includes measures of socioeconomics, health systems, geographical factors, cultural beliefs, and traditional practices. The three worst affected West African countries (Guinea, Sierra Leone, and Liberia) had the highest risk scores. The scores were much lower in developed countries that experienced Ebola compared to West African countries. A more complex risk analysis framework using 18 measures was compared with a simpler one with 10 measures, and both predicted risk equally well. A simple risk scoring system can incorporate measures of hazard and impact that may otherwise be neglected in prioritizing outbreak response. This framework can be used by public health personnel as a tool to prioritize outbreak investigation and flag outbreaks with potentially catastrophic outcomes for urgent response. Such a tool could mitigate costly delays in epidemic response. PMID:28810081
Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J
2014-05-01
Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.
Nintendo Wii assessment of Hoehn and Yahr score with Parkinson's disease tremor.
Koçer, Abdulkadir; Oktay, Ayse Betul
2016-01-01
Diagnosis of Parkinson's Disease (PD) by analyzing the resting tremor were much studied by using different accelerometer based methods, however the quantitative assessment of Hoehn and Yahr Scale (HYS) score with a machine learning based system has not been previously addressed. In this study, we aimed to propose a system to automatically assess the HYS score of patients with PD. The system was evaluated and tested on a dataset containing 55 subjects where 35 of them were patients and 20 of them were healthy controls. The resting tremor data were gathered with the 3 axis accelerometer of the Nintendo Wii (Wiimote). The clinical disability of the PD was graded from 1 to 5 by the HYS and tremor was recorded twice from the more affected side in each patient and from the dominant extremity in each control for a 60 seconds period. The HYS scores were learned with Support Vector Machines (SVM) from the features of the tremor data. Thirty-two of the subjects with PD were classified correctly and 18 of the normal subjects were also classified correctly by our system. The system had average 0.89 accuracy rate (Range: 81-100% changing according to grading by HYS). We compared quantitative measurements of hand tremor in PD patients, with staging of PD based on accelerometer data gathered using the Wii sensor. Our results showed that the machine learning based system with simple features could be helpful for diagnosis of PD and estimate HYS score. We believed that this portable and easy-to-use Wii sensor measure might also be applicable in the continuous monitoring of the resting tremor with small modifications in routine clinical use.
Toesca, Diego A S; Osmundson, Evan C; von Eyben, Rie; Shaffer, Jenny L; Koong, Albert C; Chang, Daniel T
This study aims to determine how the albumin-bilirubin (ALBI) score compares with the Child-Pugh (CP) score for assessing liver function following stereotactic body radiation therapy (SBRT). In total, 60 patients, 40 with hepatocellular carcinoma (HCC) and 20 with cholangiocarcinoma (CCA), were treated with SBRT. Liver function panels were obtained before and at 1, 3, 6, and 12 months after SBRT. Laboratory values were censored after locoregional recurrence, further liver-directed therapies, or liver transplant. A significant decline in hepatic function occurred after SBRT for HCC patients only (P = .001 by ALBI score; P < .0001 by CP score). By converting radiation doses to biologically equivalent doses by using a standard linear quadratic model using α/β of 10, the strongest dosimetric predictor of liver function decline for HCC was the volume of normal liver irradiated by a dose of 40 Gy when assessing liver function by the ALBI score (P = .07), and the volume of normal liver irradiated by a dose of 20 Gy by using the CP score (P= .0009). For CCA patients, the volume of normal liver irradiated by a dose of 40 Gy remained the strongest dosimetric predictor when using the ALBI score (P = .002), but no dosimetric predictor was significant using the CP score. Hepatic function decline correlated with worse overall survival for HCC (by ALBI, P = .0005; by CP, P < .0001) and for CCA (by ALBI, P = NS; by CP, P = .008). ALBI score was similarly able to predict hepatic function decline compared with CP score, and both systems correlated with survival. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Ahn, Shin; Rice, Terry W; Yeung, Sai-Ching J; Cooksley, Tim
2018-05-01
Patients with febrile neutropenia are a heterogeneous group with a minority developing serious medical complications. Outpatient management of low-risk febrile neutropenia has been shown to be safe and cost-effective. Scoring systems, such as the Multinational Association for Supportive Care in Cancer (MASCC) score and Clinical Index of Stable Febrile Neutropenia (CISNE), have been developed and validated to identify low-risk patients. We aimed to compare the performance of these two scores in identifying low-risk febrile neutropenic patients. We performed a pooled analysis of patients presenting with febrile neutropenia to three tertiary cancer emergency centers in the USA, UK, and South Korea in 2015. The primary outcome measures were the occurrence of serious complications. Admission to an intensive care unit (ICU) and 30-day mortality were secondary outcomes. The predictive performance of each score was analyzed. Five hundred seventy-one patients presented with febrile neutropenia. With MASCC risk index, 508 (89.1%) were classified as low-risk febrile neutropenia, compared to 60 (10.5%) with CISNE classification. Overall, the MASCC score had a greater discriminatory power in the detection of low-risk patients than the CISNE score (AUC 0.772, 95% CI 0.726-0.819 vs. 0.681, 95% CI 0.626-0.737, p = 0.0024). Both MASCC and CISNE scores have reasonable discriminatory value in predicting patients with low-risk febrile neutropenia. Risk scores should be used in conjunction with clinical judgment for the identification of patients suitable for outpatient management of neutropenic fever. Developing more accurate scores, validated in prospective settings, will be useful in facilitating more patients being managed in an outpatient setting.
Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M
2014-06-12
After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse effects (p=0.008) in renal transplant recipients receiving tacrolimus and mycophenolic acid compared to the cyclosporine regimen. This finding demonstrated construct validity. Intra-class correlation was 0.81 (95% confidence interval: 0.65-0.90) and Kappa statistic of 0.68 ± 0.25 for all 18 adverse effects and verified substantial inter-rater reliability. This immunosuppressive adverse effects scoring system in stable renal transplant recipients was evaluated and substantiated face, content and construct validity with inter-rater reliability. The scoring system may facilitate prospective, standardized clinical monitoring of immunosuppressive adverse drug effects in stable renal transplant recipients and improve medication adherence.
Race, Socioeconomic Status, and Implicit Bias: Implications for Closing the Achievement Gap
NASA Astrophysics Data System (ADS)
Schlosser, Elizabeth Auretta Cox
This study accessed the relationship between race, socioeconomic status, age and the race implicit bias held by middle and high school science teachers in Mobile and Baldwin County Public School Systems. Seventy-nine participants were administered the race Implicit Association Test (race IAT), created by Greenwald, A. G., Nosek, B. A., & Banaji, M. R., (2003) and a demographic survey. Quantitative analysis using analysis of variances, ANOVA and t-tests were used in this study. An ANOVA was performed comparing the race IAT scores of African American science teachers and their Caucasian counterparts. A statically significant difference was found (F = .4.56, p = .01). An ANOVA was also performed using the race IAT scores comparing the age of the participants; the analysis yielded no statistical difference based on age. A t-test was performed comparing the race IAT scores of African American teachers who taught at either Title I or non-Title I schools; no statistical difference was found between groups (t = -17.985, p < .001). A t-test was also performed comparing the race IAT scores of Caucasian teachers who taught at either Title I or non-Title I schools; a statistically significant difference was found between groups ( t = 2.44, p > .001). This research examines the implications of the achievement gap among African American and Caucasian students in science.
Hypoxia-induced changes in standing balance.
Wagner, Linsey S; Oakley, Sarah R; Vang, Pao; Noble, Brie N; Cevette, Michael J; Stepanek, Jan P
2011-05-01
A few studies in the literature have reported postural changes with hypoxia, but none have quantified the magnitude of change. Further understanding of this condition could have implications for patients at risk for falls, individuals undergoing acute altitude exposure, and pilots and commercial passengers. The objective of this study was to evaluate the effect of different levels of hypoxia (oxygen nitrogen mixtures) on postural standing balance using the computerized dynamic posturography (CDP) system. This improves upon previous protocols by manipulating vision and standing balance with a sway-referenced visual field and/or platform. Additionally, normative data were available for comparison with the cumulative test scores and scores for each condition. Altitude hypoxia was simulated by use of admixing nitrogen to the breathing gas to achieve equivalent altitudes of 1524 m, 2438 m, and 3048 m. Subjects were evaluated using the CDP system. Subjects showed an overall trend toward decreased performance at higher simulated altitudes consistent with the initial hypothesis. Composite standing balance sway scores for the sensory organization subtest of CDP were decreased compared to baseline for simulated altitudes as low as 2438 m (mean sway scores: 81.92 at baseline; 81.85 at 1524 m; 79.15 at 2438 m; 79.15 at 3048 m). Reaction times to unexpected movements in the support surface for the motor control subtest (MCT) increased compared to baseline (mean composite scores: 133.3 at baseline; 135.9 ms at 1524 m; 138.0 ms at 2438 m; 140.9 ms at 3048 m). The CDP testing provided a reliable objective measurement of degradation of balance under hypoxic conditions.
The Basilar Artery on Computed Tomography Angiography Prognostic Score for Basilar Artery Occlusion.
Alemseged, Fana; Shah, Darshan G; Diomedi, Marina; Sallustio, Fabrizio; Bivard, Andrew; Sharma, Gagan; Mitchell, Peter J; Dowling, Richard J; Bush, Steven; Yan, Bernard; Caltagirone, Carlo; Floris, Roberto; Parsons, Mark W; Levi, Christopher R; Davis, Stephen M; Campbell, Bruce C V
2017-03-01
Basilar artery occlusion is associated with high risk of disability and mortality. This study aimed to assess the prognostic value of a new radiological score: the Basilar Artery on Computed Tomography Angiography (BATMAN) score. A retrospective analysis of consecutive stroke patients with basilar artery occlusion diagnosed on computed tomographic angiography was performed. BATMAN score is a 10-point computed tomographic angiography-based grading system which incorporates thrombus burden and the presence of collaterals. Reliability was assessed with intraclass coefficient correlation. Good outcome was defined as modified Rankin Scale score of ≤3 at 3 months and successful reperfusion as thrombolysis in cerebral infarction 2b-3. BATMAN score was externally validated and compared with the Posterior Circulation Collateral score. The derivation cohort included 83 patients with 41 in the validation cohort. In receiver operating characteristic (ROC) analysis, BATMAN score had an area under receiver operating characteristic curve of 0.81 (95% confidence interval [CI], 0.7-0.9) in derivation cohort and an area under receiver operating characteristic curve of 0.74 (95% CI, 0.6-0.9) in validation cohort. In logistic regression adjusted for age and clinical severity, BATMAN score of <7 was associated with poor outcome in derivation cohort (odds ratio, 5.5; 95% CI, 1.4-21; P =0.01), in validation cohort (odds ratio, 6.9; 95% CI, 1.4-33; P =0.01), and in endovascular patients, after adjustment for recanalization and time to treatment (odds ratio, 4.8; 95% CI, 1.2-18; P =0.01). BATMAN score of <7 was not associated with recanalization. Interrater agreement was substantial (intraclass coefficient correlation, 0.85; 95% CI, 0.8-0.9). BATMAN score had greater accuracy compared with Posterior Circulation Collateral score ( P =0.04). The addition of collateral quality to clot burden in BATMAN score seems to improve prognostic accuracy in basilar artery occlusion patients. © 2017 American Heart Association, Inc.
Giunti, Massimo; Troia, Roberta; Bergamini, Paolo Famigli; Dondi, Francesco
2015-01-01
To investigate the prognostic value of the acute patient physiologic and laboratory evaluation (APPLE) score and relevant clinicopathological markers in dogs with systemic inflammatory response syndrome (SIRS). Prospective observational cohort study. Veterinary teaching hospital. Thirty-three dogs with SIRS admitted to the intensive care unit (ICU) were compared to 35 healthy control dogs. Dogs with SIRS were divided into septic (n = 20) and nonseptic (n = 13) etiologies and as survivors (alive to discharge, n = 22) and nonsurvivors (n = 11: died, n = 6, or humanely euthanized, n = 5). For all dogs, physiological and laboratory parameters were prospectively collected for the calculation of the APPLE fast score. No difference between septic and nonseptic SIRS dogs was detected for any parameter evaluated. Survivors had significantly higher total protein, albumin concentrations, antithrombin activity (ATA), and base excess (BE), as well as significantly lower lactate, urea, creatinine concentrations, urinary protein to creatinine ratio and APPLE fast score compared to nonsurvivors. Higher values of creatinine, lactate, anion gap, alanine transaminase (ALT), and APPLE fast score were significantly associated with an increased risk of death in SIRS dogs, while higher values of total protein, albumin, ATA, and BE were associated with a significantly reduced risk of mortality. When a multivariate binary logistic regression analysis was performed, the APPLE fast score was the only significant parameter retained. The determination of the APPLE fast score in clinical setting, as well as the measurement of APP, ATA, lactate, BE, anion gap, ALT, urinary proteins, and electrolytes may be beneficial for a better assessment of dogs with SIRS. Identified parameters were significantly related with the presence of SIRS and their evaluation should be considered for the assessment of disease severity, and guidance of the decision-making process in critically ill dogs. © Veterinary Emergency and Critical Care Society 2014.
Comparisons of Physicians' and Nurses' Attitudes towards Computers.
Brumini, Gordana; Ković, Ivor; Zombori, Dejvid; Lulić, Ileana; Bilic-Zulle, Lidija; Petrovecki, Mladen
2005-01-01
Before starting the implementation of integrated hospital information systems, the physicians' and nurses' attitudes towards computers were measured by means of a questionnaire. The study was conducted in Dubrava University Hospital, Zagreb in Croatia. Out of 194 respondents, 141 were nurses and 53 physicians, randomly selected. They surveyed by an anonymous questionnaire consisting of 8 closed questions about demographic data, computer science education and computer usage, and 30 statements on attitudes towards computers. The statements were adapted to a Likert type scale. Differences in attitudes towards computers between groups were compared using Kruskal-Wallis and Mann Whitney test for post-hoc analysis. The total score presented attitudes toward computers. Physicians' total score was 130 (97-144), while nurses' total score was 123 (88-141). It points that the average answer to all statements was between "agree" and "strongly agree", and these high total scores indicated their positive attitudes. Age, computer science education and computer usage were important factors witch enhances the total score. Younger physicians and nurses with computer science education and with previous computer experience had more positive attitudes towards computers than others. Our results are important for planning and implementation of integrated hospital information systems in Croatia.
Bonnici, Timothy; Gerry, Stephen; Wong, David; Knight, Julia; Watkinson, Peter
2016-02-09
An Early Warning Score is a clinical risk score based upon vital signs intended to aid recognition of patients in need of urgent medical attention. The use of an escalation of care policy based upon an Early Warning Score is mandated as the standard of practice in British hospitals. Electronic systems for recording vital sign observations and Early Warning Score calculation offer theoretical benefits over paper-based systems. However, the evidence for their clinical benefit is limited. Previous studies have shown inconsistent results. The majority have employed a "before and after" study design, which may be strongly confounded by simultaneously occurring events. This study aims to examine how the implementation of an electronic early warning score system, System for Notification and Documentation (SEND), affects the recognition of clinical deterioration occurring in hospitalised adult patients. This study is a non-randomised stepped wedge evaluation carried out across the four hospitals of the Oxford University Hospitals NHS Trust, comparing charting on paper and charting using SEND. We assume that more frequent monitoring of acutely ill patients is associated with better recognition of patient deterioration. The primary outcome measure is the time between a patient's first observations set with an Early Warning Score above the alerting threshold and their subsequent set of observations. Secondary outcome measures are in-hospital mortality, cardiac arrest and Intensive Care admission rates, hospital length of stay and system usability measured using the System Usability Scale. We will also measure Intensive Care length of stay, Intensive Care mortality, Acute Physiology and Chronic Health Evaluation (APACHE) II acute physiology score on admission, to examine whether the introduction of SEND has any effect on Intensive Care-related outcomes. The development of this protocol has been informed by guidance from the Agency for Healthcare Research and Quality (AHRQ) Health Information Technology Evaluation Toolkit and Delone and McLeans's Model of Information System Success. Our chosen trial design, a stepped wedge study, is well suited to the study of a phased roll out. The choice of primary endpoint is challenging. We have selected the time from the first triggering observation set to the subsequent observation set. This has the benefit of being easy to measure on both paper and electronic charting and having a straightforward interpretation. We have collected qualitative measures of system quality via a user questionnaire and organisational descriptors to help readers understand the context in which SEND has been implemented.
Liang, Chi-Cheng; Liu, Hang-Tsung; Rau, Cheng-Shyuan; Hsu, Shiun-Yuan; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2015-08-28
The aim of this study was to investigate and compare the injury pattern, mechanisms, severity, and mortality of adolescents and adults hospitalized for treatment of trauma following motorcycle accidents in a Level I trauma center. Detailed data regarding patients aged 13-19 years (adolescents) and aged 30-50 years (adults) who had sustained trauma due to a motorcycle accident were retrieved from the Trauma Registry System between January 1, 2009 and December 31, 2012. The Pearson's chi-squared test, Fisher's exact test, or the independent Student's t-test were performed to compare the adolescent and adult motorcyclists and to compare the motorcycle drivers and motorcycle pillion. Analysis of Abbreviated Injury Scale (AIS) scores revealed that the adolescent patients had sustained higher rates of facial, abdominal, and hepatic injury and of cranial, mandibular, and femoral fracture but lower rates of thorax and extremity injury; hemothorax; and rib, scapular, clavicle, and humeral fracture compared to the adults. No significant differences were found between the adolescents and adults regarding Injury Severity Score (ISS), New Injury Severity Score (NISS), Trauma-Injury Severity Score (TRISS), mortality, length of hospital stay, or intensive care unit (ICU) admission rate. A significantly greater percentage of adolescents compared to adults were found not to have worn a helmet. Motorcycle riders who had not worn a helmet were found to have a significantly lower first Glasgow Coma Scale (GCS) score, and a significantly higher percentage was found to present with unconscious status, head and neck injury, and cranial fracture compared to those who had worn a helmet. Adolescent motorcycle riders comprise a major population of patients hospitalized for treatment of trauma. This population tends to present with a higher injury severity compared to other hospitalized trauma patients and a bodily injury pattern differing from that of adult motorcycle riders, indicating the need to emphasize use of protective equipment, especially helmets, to reduce their rate and severity of injury.
Jeron, Andreas; Fredersdorf, Sabine; Debl, Kurt; Oren, Eitan; Izmirli, Alon; Peleg, Alexander; Nekovar, Anton; Herscovici, Adrian; Riegger, Günter A; Luchner, Andreas
2009-11-01
To investigate the safety and feasibility of a newly developed magnetic navigation system for intracoronary tracking. The MediGuide Medical Positioning System (MPS) is a navigation system that was developed to facilitate the navigation of enabled devices within the coronary tree using a magnetic tracking technology. The current prospective, non-randomised, single-centre, first-in-man study was conducted at Universitätsklinikum Regensburg (UKR), Germany on an MPS-enabled AXIOM Artis dFC coronary angiography system (Siemens AG, Forchheim, Germany). We enrolled 20 patients who required IVUS assessment or treatment of a single de novo target lesion in a native coronary artery. The performance was evaluated on a semi-quantitative one-to-five scale where a score of five indicates an excellent superimposition with the vessel and a score of one an unacceptable performance. The mean score for tracking as assessed by projection on life fluoroscopy was 4.89 and 3.58 as assessed by projection on recorded cine-loop. Length measurement of a 20 mm distance was significantly better with the MPS (mean deviation of 0.6 mm=3%) as compared to standard QCA (1.5 mm=8%, p<0.05). Creating a 3D reconstruction was possible in 13 out of 20 cases with an average score of 4.68. No adverse events occurred. The MediGuide Medical Positioning System is safe and feasible in man, facilitates intracoronary navigation and allows 3D reconstruction of the investigated coronary segment.
The Revised Fibromyalgia Impact Questionnaire (FIQR): validation and psychometric properties
Bennett, Robert M; Friend, Ronald; Jones, Kim D; Ward, Rachel; Han, Bobby K; Ross, Rebecca L
2009-01-01
Introduction The Fibromyalgia Impact Questionnaire (FIQ) is a commonly used instrument in the evaluation of fibromyalgia (FM) patients. Over the last 18 years, since the publication of the original FIQ, several deficiencies have become apparent and the cumbersome scoring algorithm has been a barrier to widespread clinical use. The aim of this paper is to describe and validate a revised version of the FIQ: the FIQR. Methods The FIQR was developed in response to known deficiencies of the FIQ with the help of a patient focus group. The FIQR has the same 3 domains as the FIQ (that is, function, overall impact and symptoms). It differs from the FIQ in having modified function questions and the inclusion of questions on memory, tenderness, balance and environmental sensitivity. All questions are graded on a 0–10 numeric scale. The FIQR was administered online and the results were compared to the same patient's online responses to the 36-Item Short Form Health Survey (SF-36) and the original FIQ. Results The FIQR was completed online by 202 FM patients, 51 rheumatoid arthritis (RA) or systemic lupus erythematosus (SLE) patients (31 RA and 20 SLE), 11 patients with major depressive disorder (MDD) and 213 healthy controls (HC). The mean total FIQR score was 56.6 ± 19.9 compared to a total FIQ score of 60.6 ± 17.8 (P < 0.03). The total scores of the FIQR and FIQ were closely correlated (r = 0.88, P < 0.001). Each of the 3 domains of the FIQR correlated well with the 3 related FIQ domains (r = 0.69 to 0.88, P < 0.01). The FIQR showed good correlation with comparable domains in the SF-36, with a multiple regression analysis showing that the three FIQR domain scores predicted the 8 SF-36 subscale scores. The FIQR had good discriminant ability between FM and the 3 other groups; total FIQR scores were HC (12.1 ± 11.6), RA/SLE (28.6 ± 21.2) and MDD (17.3 ± 11.8). The patient completion time was 1.3 minutes; scoring took about 1 minute. Conclusions The FIQR is an updated version of the FIQ that has good psychometric properties, can be completed in less than 2 minutes and is easy to score. It has scoring characteristics comparable to the original FIQ, making it possible to compare past FIQ results with future FIQR results. PMID:19664287
Takahashi, Yuka; Kurosaki, Masayuki; Tamaki, Nobuharu; Yasui, Yutaka; Hosokawa, Takanori; Tsuchiya, Kaoru; Nakanishi, Hiroyuki; Itakura, Jun; Izumi, Namiki
2015-06-01
To investigate the relation between systemic complications of non-alcoholic fatty liver disease (NAFLD) and non-invasive fibrosis scores. The NAFLD fibrosis score (NFS) and FIB-4 were measured in 1559 people who underwent a complete medical checkup at our hospital and were followed for more than 3 years. Correlation between these scores and prevalence and new incidence rates of diabetes or cerebral-cardiovascular diseases were analyzed. The 1559 cases were classified into two groups using the low cut-off values of NFS and FIB-4: group 1 (≥low cut-off score with fatty liver) and group 2 (the others). In group 1, the prevalence of diabetes and cerebral-cardiovascular diseases at baseline and additional incidences during the observation period was higher compared with group 2. Diabetes at baseline in group 1 versus group 2 were 31.5% versus 3.1% (NFS, P < 0.0001), 17.0% versus 4.7% (FIB-4, P < 0.0001), and cerebral-cardiovascular diseases at baseline were 7.7% versus 2.3% (NFS, P = 0.002) and 9.0% versus 2.3% (FIB-4, P = 0.0012). New incidences of diabetes were 4.5% versus 1.2% (NFS, P = 0.034) and 3.6% versus 1.2% (FIB-4, P = 0.11), and of cerebral-cardiovascular diseases were 5.0% versus 0.9% (NFS, P = 0.0019) and 5.4% versus 0.9% (FIB-4, P = 0.0034). NFS and FIB-4 are useful to extract cases with high risk of systemic complications of NAFLD in the public. © 2014 The Japan Society of Hepatology.
Gera, G; Freeman, D L; Blackinton, M T; Horak, F B; King, L
2016-02-01
Balance deficits in people with Parkinson's disease can affect any of the multiple systems encompassing balance control. Thus, identification of the specific deficit is crucial in customizing balance rehabilitation. The sensory organization test, a test of sensory integration for balance control, is sometimes used in isolation to identify balance deficits in people with Parkinson's disease. More recently, the Mini-Balance Evaluations Systems Test, a clinical scale that tests multiple domains of balance control, has begun to be used to assess balance in patients with Parkinson's disease. The purpose of our study was to compare the use of Sensory Organization Test and Mini-Balance Evaluations Systems Test in identifying balance deficits in people with Parkinson's disease. 45 participants (27M, 18F; 65.2 ± 8.2 years) with idiopathic Parkinson's disease participated in the cross-sectional study. Balance assessment was performed using the Sensory Organization Test and the Mini-Balance Evaluations Systems Test. People were classified into normal and abnormal balance based on the established cutoff scores (normal balance: Sensory Organization Test >69; Mini-Balance Evaluations Systems Test >73). More subjects were classified as having abnormal balance with the Mini-Balance Evaluations Systems Test (71% abnormal) than with the Sensory Organization Test (24% abnormal) in our cohort of people with Parkinson's disease. There were no subjects with a normal Mini-Balance Evaluations Systems Test score but abnormal Sensory Organization Test score. In contrast, there were 21 subjects who had an abnormal Mini-Balance Evaluations Systems Test score but normal Sensory Organization Test scores. Findings from this study suggest that investigation of sensory integration deficits, alone, may not be able to identify all types of balance deficits found in patients with Parkinson's disease. Thus, a comprehensive approach should be used to test of multiple balance systems to provide customized rehabilitation.
Ebinesan, Ananthan D; Sarai, Bhupinder S; Walley, Gayle; Bridgman, Stephen; Maffulli, Nicola
2006-07-31
Nearly 20,000 patients per year in the UK receive total knee arthroplasty (TKA). One of the problems faced by the health services of many developed countries is the length of time patients spend waiting for elective treatment. We therefore report the results of a study in which the Salisbury Priority Scoring System (SPSS) was used by both the surgeon and their patients to ascertain whether there were differences between the surgeon generated and patient generated Salisbury Priority Scores. The Salisbury Priority Scoring System (SPSS) was used to assign relative priority to patients with knee osteoarthritis as part of a randomised controlled trial comparing the standard medial parapatellar approach versus the sub-vastus approach in TKA. The operating surgeons and each patient completed the SPSS at the same pre-assessment clinic. The SPSS assesses four criteria, namely progression of disease, pain or distress, disability or dependence on others, and loss of usual occupation. Crosstabs and agreement measures (Cohen's kappa) were performed. Overall, the four SPSS criteria showed a kappa value of 0.526, 0.796, 0.813, and 0.820, respectively, showing moderate to very good agreement between the patient and the operating consultant. Male patients showed better agreement than female patients. The Salisbury Priority Scoring System is a good means of assessing patients' needs in relation to elective surgery, with high agreement between the patient and the operating surgeon.
A prospective study on MRI findings and prognostic factors in athletes with MTSS.
Moen, M H; Schmikli, S L; Weir, A; Steeneken, V; Stapper, G; de Slegte, R; Tol, J L; Backx, F J G
2014-02-01
In medial tibial stress syndrome (MTSS) bone marrow and periosteal edema of the tibia on the magnetic resonance imaging (MRI) is frequently reported. The relationship between these MRI findings and recovery has not been previously studied. This prospective study describes MRI findings of 52 athletes with MTSS. Baseline characteristics were recorded and recovery was related to these parameters and MRI findings to examine for prognostic factors. Results showed that 43.5% of the symptomatic legs showed bone marrow or periosteal edema. Absence of periosteal and bone marrow edema on MRI was associated with longer recovery (P = 0.033 and P = 0.013). A clinical scoring system for sports activity (SARS score) was significantly higher in the presence of bone marrow edema (P = 0.027). When clinical scoring systems (SARS score and the Lower Extremity Functional Scale) were combined in a model, time to recovery could be predicted substantially (explaining 54% of variance, P = 0.006). In conclusion, in athletes with MTSS, bone marrow or periosteal edema is seen on MRI in 43,5% of the symptomatic legs. Furthermore, periosteal and bone marrow edema on MRI and clinical scoring systems are prognostic factors. Future studies should focus on MRI findings in symptomatic MTSS and compare these with a matched control group. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Nurse-patient assignment models considering patient acuity metrics and nurses' perceived workload.
Sir, Mustafa Y; Dundar, Bayram; Barker Steege, Linsey M; Pasupathy, Kalyan S
2015-06-01
Patient classification systems (PCSs) are commonly used in nursing units to assess how many nursing care hours are needed to care for patients. These systems then provide staffing and nurse-patient assignment recommendations for a given patient census based on these acuity scores. Our hypothesis is that such systems do not accurately capture workload and we conduct an experiment to test this hypothesis. Specifically, we conducted a survey study to capture nurses' perception of workload in an inpatient unit. Forty five nurses from oncology and surgery units completed the survey and rated the impact of patient acuity indicators on their perceived workload using a six-point Likert scale. These ratings were used to calculate a workload score for an individual nurse given a set of patient acuity indicators. The approach offers optimization models (prescriptive analytics), which use patient acuity indicators from a commercial PCS as well as a survey-based nurse workload score. The models assign patients to nurses in a balanced manner by distributing acuity scores from the PCS and survey-based perceived workload. Numerical results suggest that the proposed nurse-patient assignment models achieve a balanced assignment and lower overall survey-based perceived workload compared to the assignment based solely on acuity scores from the PCS. This results in an improvement of perceived workload that is upwards of five percent. Copyright © 2015 Elsevier Inc. All rights reserved.
Cook, Devon R; Harris, Edward F; Vaden, James L
2005-06-01
Treatment outcomes and duration of treatment for patients treated in university graduate orthodontic programs and private orthodontic practices were assessed and compared with the ABO objective grading system. The treatment records of 139 randomly selected adolescents who had received comprehensive orthodontic treatment were examined. Seventy-seven subjects had been treated in 3 postgraduate orthodontic clinics, and 62 had been treated in 3 private orthodontic practices. Pretreatment, all subjects had Class II Division 1 malocclusions and ANB angles equal to or greater than 4 degrees . All patients were treated with premolar extractions. Posttreatment dental casts were measured and scored with the ABO objective grading system. No significant differences were found between the groups in the alignment, buccolingual inclination, and overjet components. Patients treated in private practice had significantly lower scores for marginal ridge height and occlusal relationship. Patients treated in the university programs had significantly lower scores for occlusal contact and interproximal contact components. There was no significant difference in the overall score, thus no significant difference in the overall quality of orthodontic treatment outcome between patients treated in university programs and private practices. However, the university group had a significantly larger sample variance for the overall score. There was no significant difference in the duration of the treatment between patients treated in a university setting and in a private practice.
Scoring Coreference Partitions of Predicted Mentions: A Reference Implementation.
Pradhan, Sameer; Luo, Xiaoqiang; Recasens, Marta; Hovy, Eduard; Ng, Vincent; Strube, Michael
2014-06-01
The definitions of two coreference scoring metrics- B 3 and CEAF-are underspecified with respect to predicted , as opposed to key (or gold ) mentions. Several variations have been proposed that manipulate either, or both, the key and predicted mentions in order to get a one-to-one mapping. On the other hand, the metric BLANC was, until recently, limited to scoring partitions of key mentions. In this paper, we (i) argue that mention manipulation for scoring predicted mentions is unnecessary, and potentially harmful as it could produce unintuitive results; (ii) illustrate the application of all these measures to scoring predicted mentions; (iii) make available an open-source, thoroughly-tested reference implementation of the main coreference evaluation measures; and (iv) rescore the results of the CoNLL-2011/2012 shared task systems with this implementation. This will help the community accurately measure and compare new end-to-end coreference resolution algorithms.
Impact of Residency Training Redesign on Residents' Clinical Knowledge.
Waller, Elaine; Eiff, M Patrice; Dexter, Eve; Rinaldo, Jason C B; Marino, Miguel; Garvin, Roger; Douglass, Alan B; Phillips, Robert; Green, Larry A; Carney, Patricia A
2017-10-01
The In-training Examination (ITE) is a frequently used method to evaluate family medicine residents' clinical knowledge. We compared family medicine ITE scores among residents who trained in the 14 programs that participated in the Preparing the Personal Physician for Practice (P4) Project to national averages over time, and according to educational innovations. The ITE scores of 802 consenting P4 residents who trained in 2007 through 2011 were obtained from the American Board of Family Medicine. The primary analysis involved comparing scores within each academic year (2007 through 2011), according to program year (PGY) for P4 residents to all residents nationally. A secondary analysis compared ITE scores among residents in programs that experimented with length of training and compared scores among residents in programs that offered individualized education options with those that did not. Release of ITE scores was consented to by 95.5% of residents for this study. Scores of P4 residents were higher compared to national scores in each year. For example, in 2011, the mean P4 score for PGY1 was 401.2, compared to the national average of 386. For PGY2, the mean P4 score was 443.1, compared to the national average of 427, and for PGY3, the mean P4 score was 477.0, compared to the national PGY3 score of 456. Scores of residents in programs that experimented with length of training were similar to those in programs that did not. Scores were also similar between residents in programs with and without individualized education options. Family medicine residency programs undergoing substantial educational changes, including experiments in length of training and individualized education, did not appear to experience a negative effect on resident's clinical knowledge, as measured by ITE scores. Further research is needed to study the effect of a wide range of residency training innovations on ITE scores over time.
[Development and validation of the Visual Analogue Scale (VAS) Spine Score].
Knop, C; Oeser, M; Bastian, L; Lange, U; Zdichavsky, M; Blauth, M
2001-06-01
The aim of the study was the development and validation of a new subjective rating scale for assessment of outcome in patients with thoracolumbar fractures and fracture dislocations. The VAS spine score consists of 19 score items, using 100-mm visual analogue scales. The items are answered by the patients independently of rater assessment. To measure the analogue scales and calculate the score, a computer-aided system was evolved consisting of self-developed software and digitizer board. The overall score is the mean of all items answered with values between 0 and 100. The individual score loss is calculated as the difference between the preinjury score and at follow-up with values between 0 and 100. The VAS spine score was tested for reliability with a group of 136 healthy volunteers. We performed a test-retest study with an interval of 24 h. For statistical analysis of the validity, we prospectively followed a group of 53 patients with the new outcome score. We chose patients with injuries of the thoracolumbar spine, all having been operatively treated by combined posterior-anterior stabilization and fusion between 1994 and 1996. In the reference group, the average test score was 91.95 (58-100) and 92.10 (58-100) at retest. The mean individual difference between test and retest scored 1.037 (0-8). A high reliability was proved by a strong correlation with a coefficient of 0.976 (p < 0.001). A high internal consistency of the VAS spine score was shown by a Cronbach-alpha of 0.9117. The mean score for the preinjury status of the patients was comparable to the reference group, amounting to 89.60 (21-100). The mean score at the time of implant removal was significantly (p < 0.001) decreased to 58.25 (13-97). Until the time of follow-up a significant (p < 0.001) increase was noted, and the group scored 66.08 (15-100) at follow-up. This was a significant (p < 0.001) difference compared with the preinjury status. The individual score loss averaged 24.1 (0-80). In the patient group we also noted a Cronbach-alpha > 0.95, indicating a high internal consistency. With the VAS spine score the authors have inaugurated a new tool for outcome measurement in the treatment of patients with thoracolumbar injuries. The study has proved the score to be both reliable and valid. The application of the score is helpful in analyzing the subjective outcome, and the results can be correlated with objective measures. The score is a useful tool for comparative clinical studies, addressing the outcome after different methods of treatment.
Yee, Chee-Seng; Farewell, Vernon; Isenberg, David A; Rahman, Anisur; Teh, Lee-Suan; Griffiths, Bridget; Bruce, Ian N; Ahmad, Yasmeen; Prabu, Athiveeraramapandian; Akil, Mohammed; McHugh, Neil; D'Cruz, David; Khamashta, Munther A; Maddison, Peter; Gordon, Caroline
2007-01-01
Objective To determine the construct and criterion validity of the British Isles Lupus Assessment Group 2004 (BILAG-2004) index for assessing disease activity in systemic lupus erythematosus (SLE). Methods Patients with SLE were recruited into a multicenter cross-sectional study. Data on SLE disease activity (scores on the BILAG-2004 index, Classic BILAG index, and Systemic Lupus Erythematosus Disease Activity Index 2000 [SLEDAI-2K]), investigations, and therapy were collected. Overall BILAG-2004 and overall Classic BILAG scores were determined by the highest score achieved in any of the individual systems in the respective index. Erythrocyte sedimentation rates (ESRs), C3 levels, C4 levels, anti–double-stranded DNA (anti-dsDNA) levels, and SLEDAI-2K scores were used in the analysis of construct validity, and increase in therapy was used as the criterion for active disease in the analysis of criterion validity. Statistical analyses were performed using ordinal logistic regression for construct validity and logistic regression for criterion validity. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results Of the 369 patients with SLE, 92.7% were women, 59.9% were white, 18.4% were Afro-Caribbean and 18.4% were South Asian. Their mean ± SD age was 41.6 ± 13.2 years and mean disease duration was 8.8 ± 7.7 years. More than 1 assessment was obtained on 88.6% of the patients, and a total of 1,510 assessments were obtained. Increasing overall scores on the BILAG-2004 index were associated with increasing ESRs, decreasing C3 levels, decreasing C4 levels, elevated anti-dsDNA levels, and increasing SLEDAI-2K scores (all P < 0.01). Increase in therapy was observed more frequently in patients with overall BILAG-2004 scores reflecting higher disease activity. Scores indicating active disease (overall BILAG-2004 scores of A and B) were significantly associated with increase in therapy (odds ratio [OR] 19.3, P < 0.01). The BILAG-2004 and Classic BILAG indices had comparable sensitivity, specificity, PPV, and NPV. Conclusion These findings show that the BILAG-2004 index has construct and criterion validity. PMID:18050213
ERIC Educational Resources Information Center
Curby, Timothy W.; Johnson, Price; Mashburn, Andrew J.; Carlis, Lydia
2016-01-01
When conducting classroom observations, researchers are often confronted with the decision of whether to conduct observations live or by using pre-recorded video. The present study focuses on comparing and contrasting observations of live and video administrations of the Classroom Assessment Scoring System-PreK (CLASS-PreK). Associations between…
Haran, F Jay; Slaboda, Jill C; King, Laurie A; Wright, W Geoff; Houlihan, Daniel; Norris, Jacob N
2016-04-01
This study evaluated the utility of the Balance Error Scoring System (BESS) and the Sensory Organization Test (SOT) as tools for the screening and monitoring of Service members (SMs) with mild traumatic brain injury (mTBI) in a deployed setting during the acute and subacute phases of recovery. Patient records (N = 699) were reviewed for a cohort of SMs who sustained a blast-related mTBI while deployed to Afghanistan and were treated at the Concussion Restoration Care Center (CRCC) at Camp Leatherneck. On initial intake into the CRCC, participants completed two assessments of postural control, the BESS, and SOT. SMs with mTBI performed significantly worse on the BESS and SOT when compared with comparative samples. When the SOT data were further examined using sensory ratios, the results indicated that postural instability was primarily a result of vestibular and visual integration dysfunction (r > 0.62). The main finding of this study was that the sensitivity of the SOT composite score (50-58%) during the acute phase was higher than previous sensitivities found in the sports medicine literature for impact-related trauma.
Buczinski, S; Faure, C; Jolivet, S; Abdallah, A
2016-07-01
To determine inter-observer agreement for a clinical scoring system for the detection of bovine respiratory disease complex in calves, and the impact of classification of calves as sick or healthy based on different cut-off values. Two third-year veterinary students (Observer 1 and 2) and one post-graduate student (Observer 3) received 4 hours of training on scoring dairy calves for signs of respiratory disease, including rectal temperature, cough, eye and nasal discharge, and ear position. Observers 1 and 2 scored 40 pre-weaning dairy calves 24 hours apart (80 observations) over three visits to a calf-rearing facility, and Observers 1, 2 and 3 scored 20 calves on one visit. Inter-observer agreement was assessed using percentage of agreement (PA) and Kappa statistics for individual clinical signs, comparing Observers 1 and 2. Agreement between the three observers for total clinical score was assessed using cut-off values of ≥4, ≥5 and ≥6 to indicate unhealthy calves. Inter-observer PA for rectal temperature was 0.68, for cough 0.78, for nasal discharge 0.62, for eye discharge 0.63, and for ear position 0.85. Kappa values for all clinical signs indicated slight to fair agreement (<0.4), except temperature that had moderate agreement (0.6). The Fleiss' Kappa for total score, using cut-offs of ≥4, ≥5 and ≥6 to indicate unhealthy calves, was 0.35, 0.06 and 0.13, respectively, indicating slight to fair agreement. There was important inter-observer discrepancies in scoring clinical signs of respiratory disease, using relatively inexperienced observers. These disagreements may ultimately mean increased false negative or false positive diagnoses and incorrect treatment of cases. Visual assessment of clinical signs associated with bovine respiratory disease needs to be thoroughly validated when disease monitoring is based on the use of a clinical scoring system.
Estimating chemical ecotoxicity in EU ecolabel and in EU product environmental footprint.
Saouter, Erwan; De Schryver, An; Pant, Rana; Sala, Serenella
2018-05-21
The EU Commission Ecolabel and the Product and Environmental Footprint (PEF) aim at promoting the development and consumption of greener products. The product aquatic toxicity score from these 2 methods may lead in some circumstances to opposite conclusions. Although this could be interpreted as an inconsistency, the score should not be compared to each other but used in a complementary way. In short, CDV provided a "full" product formula aquatic toxicity score, even if some chemicals may never reach or persist in freshwater ecosystems. The USEtox® score, by integrating fate and exposure, focuses on the potential toxicity of persistent-water-soluble chemicals at steady state. Since no risk or safety assessment can be conducted with USEtox® nor with the CDV, both are a hazard-based scoring system. This short communication clarifies the difference between approaches underpinning the toxicity scores used in Ecolabel and PEF, providing guidance on how to interpret the results. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Development and initial validation of the Bedside Paediatric Early Warning System score
2009-01-01
Introduction Adverse outcomes following clinical deterioration in children admitted to hospital wards is frequently preventable. Identification of children for referral to critical care experts remains problematic. Our objective was to develop and validate a simple bedside score to quantify severity of illness in hospitalized children. Methods A case-control design was used to evaluate 11 candidate items and identify a pragmatic score for routine bedside use. Case-patients were urgently admitted to the intensive care unit (ICU). Control-patients had no 'code blue', ICU admission or care restrictions. Validation was performed using two prospectively collected datasets. Results Data from 60 case and 120 control-patients was obtained. Four out of eleven candidate-items were removed. The seven-item Bedside Paediatric Early Warning System (PEWS) score ranges from 0–26. The mean maximum scores were 10.1 in case-patients and 3.4 in control-patients. The area under the receiver operating characteristics curve was 0.91, compared with 0.84 for the retrospective nurse-rating of patient risk for near or actual cardiopulmonary arrest. At a score of 8 the sensitivity and specificity were 82% and 93%, respectively. The score increased over 24 hours preceding urgent paediatric intensive care unit (PICU) admission (P < 0.0001). In 436 urgent consultations, the Bedside PEWS score was higher in patients admitted to the ICU than patients who were not admitted (P < 0.0001). Conclusions We developed and performed the initial validation of the Bedside PEWS score. This 7-item score can quantify severity of illness in hospitalized children and identify critically ill children with at least one hours notice. Prospective validation in other populations is required before clinical application. PMID:19678924
Feagan, B G; Hanauer, S B; Coteur, G; Schreiber, S
2011-05-01
Successful treatment of systemic inflammatory symptoms is essential for improving health-related quality of life in patients with active Crohn's disease. Patient-reported outcomes provide unique perspectives on the impact of chronic disease. It is unknown whether a combination of different instruments might improve sensitivity to clinically relevant changes in health status. To develop a composite score based upon Crohn's Disease Activity Index (CDAI) and Inflammatory Bowel Disease Questionnaire (IBDQ) items. Patients from the PRECiSE 2 trial who responded at week 6 to certolizumab pegol (CZP) were randomised to receive treatment with CZP 400 mg or placebo for up to 26 weeks. IBDQ and CDAI scores were assessed at weeks 0, 6, 16 and 26. A 'daily practice' composite score (DP-6) containing two items from the CDAI and four items from IBDQ was constructed. Correlation coefficients between the CDAI score and IBDQ total score at baseline and at week 26 were -0.344 and -0.603, respectively (P<0.05). All IBDQ items were improved following CZP treatment. The DP-6 had the highest responsiveness at assessing response to treatment, relative to CDAI total score, when compared with other scores. The DP-6 composite score could be used to optimise the use of existing instruments by serving as an index of symptoms due to systemic inflammation. Additional studies are needed to determine if the DP-6 composite score differentiates the impact of different treatments on patient-reported outcomes, and to determine if the use of the DP-6 improves the care of patients in clinical practice. © 2011 Blackwell Publishing Ltd.
Atherosclerotic involvement in patients with left or right dominant coronary circulation.
Balci, Bahattin; Yilmaz, Ozcan
2004-06-01
There are variations in the anatomy of the coronary arteries in patients with left dominant circulation. The influence of anatomical variations in patients with left dominant circulation on coronary arteriosclerosis is not clear. We investigated whether atherosclerotic involvement in patients with left dominant circulation differs from that in patients with right dominant circulation. We retrospectively compared 38 consecutive angiograms with left coronary dominance with 459 consecutive angiograms with right coronary dominance. By using the 29-segment coding system of the American College of Cardiology/American Heart Association, numerical values were given to each segment, according to the percentage of the decrease in luminary diameter. Using, the sum of numerical values in each coronary artery, LAD score, LCx score, RCA score, and left main coronary artery (LMCA) score were obtained. Using the sum of these 4 vessel scores, the coronary artery disease (CAD) score was calculated. Total LAD score (49+/-48 vs 47+/-57), total LCx score (29+/-45 vs 41+/-58), total RCA score (32+/-68 vs 30+/-51), total LMCA score (1.8+/-11.3 vs 2.9+/-13.6) and total CAD score (108+/-108 vs 108+/-123) were similar in patients with left and right dominant circulation (all differences NS). The extent of coronary atherosclerosis does not depend on the type of dominant coronary circulation.
Lee, Brian J; Marks, Malcolm; Smith, Dell P; Hodges-Savola, Cheryl A; Mischke, Jennifer M; Lewis, Ryan D
2014-10-01
Use of electrosurgery for skin incisions has been controversial due to concerns of delayed healing, excessive scarring, and increased infection. Recent studies using modern electrosurgical generators that produce pure sinusoidal "CUT" waveforms have shown reductions in thermal damage along incisions made with these devices compared with their predecessors. This study compares scar formation in incisions made using a cold steel scalpel (CSS) or the ACE Blade and Mega Power Generator (ACE system, Megadyne Medical Products, Draper, Utah) from patient and blinded observer perspectives. Subjects seeking plastic surgery were enrolled in the study. Incisions on one side of each subject's body were made with a CSS while equivalent incisions on the contralateral side were made with the ACE system. Differences between incision methods were evaluated by assessment of scar formation by observers and assessment of patient satisfaction relating to scar formation at 120 days postsurgery. Observers rated incision vascularization, pigmentation, thickness, and relief. The mean observer score (± SD) of incisions made with the ACE system was 11.1 ± 4.4 while that of incisions made with the CSS was 10.8 ± 3.7 (P < 0.0001). Patients rated incision pain, itching, discoloration, stiffness, thickness, and irregularity. The mean patient score of incisions made with the ACE system was 9.4 ± 9.2 while that of incisions made with the CSS was 9.3 ± 8.5 (P < 0.0001). Results showed noninferior wound healing/scar formation in skin incisions made with the ACE system compared with incisions made with a CSS.
[Scoring systems in intensive care medicine : principles, models, application and limits].
Fleig, V; Brenck, F; Wolff, M; Weigand, M A
2011-10-01
Scoring systems are used in all diagnostic areas of medicine. Several parameters are evaluated and rated with points according to their value in order to simplify a complex clinical situation with a score. The application ranges from the classification of disease severity through determining the number of staff for the intensive care unit (ICU) to the evaluation of new therapies under study conditions. Since the introduction of scoring systems in the 1980's a variety of different score models has been developed. The scoring systems that are employed in intensive care and are discussed in this article can be categorized into prognostic scores, expenses scores and disease-specific scores. Since the introduction of compulsory recording of two scoring systems for accounting in the German diagnosis-related groups (DRG) system, these tools have gained more importance for all intensive care physicians. Problems remain in the valid calculation of scores and interpretation of the results.
Carr, R A; Sanders, D S A; Stores, O P; Smew, F A; Parkes, M E; Ross‐Gilbertson, V; Chachlani, N; Simon, J
2006-01-01
Background Guidelines on staffing and workload for histopathology and cytopathology departments was published by the Royal College of Pathologists (RCPath) in July 2003. In this document, a system is provided whereby the workload of a cellular pathology department and individual pathologists can be assessed with a scoring system based on specialty and complexity of the specimens. A similar, but simplified, system of scoring specimens by specialty was developed in the Warwick District General Hospital. The system was based on the specimen type and suggested clinical diagnosis, so that specimens could be allocated prospectively by the laboratory technical staff to even out workload and support subspecialisation in a department staffed by 4.6 whole‐time equivalent consultant pathologists. Methods The pathologists were asked to indicate their reporting preferences to determine specialist reporting teams. The workload was allocated according to the “prospective” Warwick system (based on specimen type and suggested clinical diagnosis, not affected by final diagnosis or individual pathologist variation in reference to numbers of blocks, sections and special stains examined) for October 2003. The cumulative Warwick score was compared with the “retrospective” RCPath scoring system for each pathologist and between specialties. Four pathologists recorded their time for cut‐up and reporting for the month audited. Results The equitable distribution of work between pathologists was ensured by the Warwick allocation and workload system, hence facilitating specialist reporting. Less variation was observed in points reported per hour by the Warwick system (6.3 (range 5.5–6.9)) than by the RCPath system (11.5 (range 9.3–15)). Conclusions The RCPath system of scoring is inherently complex, is applied retrospectively and is not consistent across subspecialities. The Warwick system is simpler, prospective and can be run by technical staff; it facilitates even workload distribution throughout the day. Subspecialisation within a small‐sized or medium‐sized department with fair distribution of work between pathologists is also allowed for by this system. Reporting times among pathologists were shown by time and motion studies to be more consistent with Warwick points per hour than with RCPath points per hour. PMID:16524963
Doud, Andrea N; Schoell, Samantha L; Talton, Jennifer W; Barnard, Ryan T; Petty, John K; Stitzel, Joel D; Weaver, Ashley A
2018-04-01
Occult injuries are those likely to be missed on initial assessment by first responders and, though initially asymptomatic, they may present suddenly and lead to rapid patient decompensation. No scoring systems to quantify the occultness of pediatric injuries have been established. Such a scoring system will be useful in the creation of an Advanced Automotive Crash Notification (AACN) system that assists first responders in making triage decisions following a motor vehicle crash (MVC). The most frequent MVC injuries were determined for 0-4, 5-9, 10-14 and 15-18 year olds. For each age-specific injury, experts with pediatric trauma expertise were asked to rate the likelihood that the injury may be missed by first responders. An occult score (ranging from 0-1) was calculated by averaging and normalizing the responses of the experts polled. Evaluation of all injuries across all age groups demonstrated greater occult scores for the younger age groups compared to older age groups (mean occult score 0-4yo: 0.61 ± 0.23, 5-9yo: 0.53 ± 0.25, 10-14yo: 0.48 ± 0.23, and 15-18yo: 0.42 ± 0.22, p < 0.01). Body-region specific occult scores revealed that experts judged abdominal, spine and thoracic injuries to be more occult than injuries to other body regions. The occult scores suggested that injuries are more difficult to detect in younger age groups, likely given their inability to express symptoms. An AACN algorithm that can predict the presence of clinically undetectable injuries at the scene can improve triage of children with these injuries to higher levels of care. Copyright © 2018 Elsevier Ltd. All rights reserved.
Oner, Gokalp; Ulug, Pasa; Demirci, Elif; Kumtepe, Yakup; Gündogdu, Cemal
2015-01-01
To evaluate the effects of fulvestrant and micronized progesterone on post-operative adhesion formation and ovarian reserve in a rat uterine horn adhesion. In this prospective randomized controlled trial, 32 female Wistar albino rats were randomly divided into four groups including control group (Group 1), the control adhesion group (Group 2), 1 mg/kg daily intramuscular fulvestrant received group (Group 3) and 1 mg/kg daily oral micronized progesterone received group (Group 4). The extent and severity of adhesions were scored and samples were taken from adhesion areas to investigate the grades of adhesions according to the immunohistochemical scoring system. Ovarian reserves were measured with anti-Müllerian hormone (AMH) and histological ovarian follicles count. The extent, severity and total adhesion scores were reduced in all treatment groups compared to control adhesion group (Group 2). Similarly, immunohistochemical adhesion scores were lower in the treatment groups. AMH and follicle count were significantly found lower in adhesion groups compared with control group. However, treatment groups were found to have higher ovarian reserve compared to control adhesion group (Group 2). Fulvestrant and micronized progesterone were found to reduce post-operative adhesion formations and have decreased detrimental effects of adhesion formation on ovarian reserve.
The effect of dose reduction on the detection of anatomical structures on panoramic radiographs.
Kaeppler, G; Dietz, K; Reinert, S
2006-07-01
The aim was to evaluate the effect of dose reduction on diagnostic accuracy using different screen-film combinations and digital techniques for panoramic radiography. Five observers assessed 201 pairs of panoramic radiographs (a total of 402 panoramic radiographs) taken with the Orthophos Plus (Sirona, Bensheim, Germany), for visualization of 11 anatomical structures on each side, using a 3-point scale -1, 0 and 1. Two radiographs of each patient were taken at two different times (conventional setting and setting with decreased dose, done by increasing tube potential settings or halving tube current). To compare the dose at different tube potential settings dose-length product was measured at the secondary collimator. Films with medium and regular intensifying screens (high and low tube potential settings) and storage phosphor plates (low tube potential setting, tube current setting equivalent to regular intensifying screen and halved) were compared. The five observers made 27 610 assessments. Intrarater agreement was expressed by Cohen's kappa coefficient. The results demonstrated an equivalence of regular screens (low tube potential setting) and medium screens (high and low tube potential settings). A significant difference existed between medium screens (low tube potential setting, mean score 0.92) and the group of regular film-screen combinations at high tube potential settings (mean score 0.89) and between all film-screen combinations and the digital system irrespective of exposure (mean score below 0.82). There were no significant differences between medium and regular screens (mean score 0.88 to 0.92) for assessment of the periodontal ligament space, but there was a significant difference compared with the digital system (mean score below 0.76). The kappa coefficient for intrarater agreement was moderate (0.55). New regular intensifying screens can replace medium screens at low tube potential settings. Digital panoramic radiographs should be taken at low tube potential levels with an exposure equivalent at least to a regular intensifying screen.
Assessing Hourly Precipitation Forecast Skill with the Fractions Skill Score
NASA Astrophysics Data System (ADS)
Zhao, Bin; Zhang, Bo
2018-02-01
Statistical methods for category (yes/no) forecasts, such as the Threat Score, are typically used in the verification of precipitation forecasts. However, these standard methods are affected by the so-called "double-penalty" problem caused by slight displacements in either space or time with respect to the observations. Spatial techniques have recently been developed to help solve this problem. The fractions skill score (FSS), a neighborhood spatial verification method, directly compares the fractional coverage of events in windows surrounding the observations and forecasts. We applied the FSS to hourly precipitation verification by taking hourly forecast products from the GRAPES (Global/Regional Assimilation Prediction System) regional model and quantitative precipitation estimation products from the National Meteorological Information Center of China during July and August 2016, and investigated the difference between these results and those obtained with the traditional category score. We found that the model spin-up period affected the assessment of stability. Systematic errors had an insignificant role in the fraction Brier score and could be ignored. The dispersion of observations followed a diurnal cycle and the standard deviation of the forecast had a similar pattern to the reference maximum of the fraction Brier score. The coefficient of the forecasts and the observations is similar to the FSS; that is, the FSS may be a useful index that can be used to indicate correlation. Compared with the traditional skill score, the FSS has obvious advantages in distinguishing differences in precipitation time series, especially in the assessment of heavy rainfall.
Lenghel, Lavinia Manuela; Botar Jid, Carolina; Bolboaca, Sorana D; Ciortea, Cristiana; Vasilescu, Dan; Baciut, Grigore; Dudea, Sorin M
2015-06-01
The aim of the study was to explore the diagnostic value of three different sonoelastographic scoring systems (labeled S1-S3) for the differentiation between benign and malignant cervical lymph nodes. The authors propose a six pattern scoring system of the elastographic images with pattern 1 - representing purely soft nodes, pattern 2 - predominantly soft nodes, pattern 3 - predominantly soft nodes with focal had area, pattern 4 - predominantly hard node, pattern 5 - entirely hard node and pattern 6 - node with necrosis. The sonoelastographic images of 50 benign and 70 malignant lymph nodes were assessed. The area under the ROC curve (AUROC) for the differentiation between benign vs. malignant and benign vs. metastatic nodes were analyzed for the three scoring systems. When all the malignant lymph nodes were considered, the S1 score showed an AUROC=0.873 (95%CI [0.805-0.918], where CI=confidence interval; p<0.001), sensibility (Se)=58.57%, and specificity (Sp)=96%. For S2 score the AUROC was 0.890 (95%CI [0.824-0.933], p<0.001), Se=92.86%, and Sp=72%. For S3 score, the AUROC was 0.852 (95%CI [0.778-0.902], p<0.001), Se=64.29%, and Sp=94%). When lymphomatous nodes were excluded, for S1 the AUROC was 0.884 (95%CI [0.809-0.932], p<0.001), Se=64%, and Sp=96%. For S2 the AUROC was 0.894 (95%CI [0.818-0.939], p<0.001), Se=92%, and Sp=72%. For S3, the AUROC was 0.856 (95%CI [0.771-0.911], p<0.001), Se=66%, and Sp=94%. In the S3 scoring system, setting the benign vs. malignant cut off at pattern 3 increases the sensibility (41-65%) with minimal loss of specificity (96-94%). From the gray-scale and Doppler criteria, changes of the nodular margins and the presence of the vessels in the cortical part of the lymph node showed both very high sensibility and specificity, the others criteria taken into account had either very good sensibility with low specificity or high specificity and low sensibility. Our study suggests that there are no significant differences between the three scoring systems in terms of overall diagnostic value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Rechmann, Peter; Liou, Shasan W; Rechmann, Beate M T; Featherstone, John D B
2016-01-01
The hypothesis to be tested was that using the SOPROCARE system in fluorescence perio-mode allows scoring of microbial plaque that is comparable to the Turesky modification of the Quigley Hein plaque index (T-QH) and scoring of gingival inflammation comparable to the Silness and Löe gingival inflammation index (GI). Fifty-five subjects with various amounts of microbial plaque were recruited. The T-QH and GI index were recorded. SOPROCARE pictures were recorded in fluorescence perio-mode and in daylight mode. Finally, conventional digital photographs were taken. All pictures were assessed using the same criteria as described for the clinical indices. The average T-QH was 1.1 ± 1.2 (mean ± SD). Scoring with SOPROCARE perio-mode led to a slightly higher average than the T-QH scores. SOPROCARE daylight mode and digital photography showed the highest plaque scores. The average GI index was 0.7 ± 0.9. SOPROCARE in perio-mode scored slightly lower. Linear regression fits between the different clinical indices and SOPROCARE scores were significantly different from zero demonstrating high goodness of fit. The study demonstrated that the SOPROCARE fluorescence assessment tool in perio-mode allows reliable judgment of microbial plaque and gingival inflammation levels similar to the established Turesky-modified Quigley Hein index and the Silness and Löe gingival inflammation index. Training on plaque-free teeth will actually reduce scoring errors. The SOPROCARE fluorescence tool in perio-mode provides reliable evaluation of microbial plaque and gingival inflammation for the dental clinician.
Does the Aristotle Score predict outcome in congenital heart surgery?
Kang, Nicholas; Tsang, Victor T; Elliott, Martin J; de Leval, Marc R; Cole, Timothy J
2006-06-01
The Aristotle Score has been proposed as a measure of 'complexity' in congenital heart surgery, and a tool for comparing performance amongst different centres. To date, however, it remains unvalidated. We examined whether the Basic Aristotle Score was a useful predictor of mortality following open-heart surgery, and compared it to the Risk Adjustment in Congenital Heart Surgery (RACHS-1) system. We also examined the ability of the Aristotle Score to measure performance. The Basic Aristotle Score and RACHS-1 risk categories were assigned retrospectively to 1085 operations involving cardiopulmonary bypass in children less than 18 years of age. Multiple logistic regression analysis was used to determine the significance of the Aristotle Score and RACHS-1 category as independent predictors of in-hospital mortality. Operative performance was calculated using the Aristotle equation: performance = complexity x survival. Multiple logistic regression identified RACHS-1 category to be a powerful predictor of mortality (Wald 17.7, p < 0.0001), whereas Aristotle Score was only weakly associated with mortality (Wald 4.8, p = 0.03). Age at operation and bypass time were also highly significant predictors of postoperative death (Wald 13.7 and 33.8, respectively, p < 0.0001 for both). Operative performance was measured at 7.52 units. The Basic Aristotle Score was only weakly associated with postoperative mortality in this series. Operative performance appeared to be inflated by the fact that the overall complexity of cases was relatively high in this series. An alternative equation (performance = complexity/mortality) is proposed as a fairer and more logical method of risk-adjustment.
Gross, Brooks A.; Walsh, Christine M.; Turakhia, Apurva A.; Booth, Victoria; Mashour, George; Poe, Gina R.
2009-01-01
Manual state scoring of physiological recordings in sleep studies is time-consuming, resulting in a data backlog, research delays and increased personnel costs. We developed MATLAB-based software to automate scoring of sleep/waking states in rats, potentially extendable to other animals, from a variety of recording systems. The software contains two programs, Sleep Scorer and Auto-Scorer, for manual and automated scoring. Auto-Scorer is a logic-based program that displays power spectral densities of an electromyographic signal and σ, δ, and θ frequency bands of an electroencephalographic signal, along with the δ/θ ratio and σ ×θ, for every epoch. The user defines thresholds from the training file state definitions which the Auto-Scorer uses with logic to discriminate the state of every epoch in the file. Auto-Scorer was evaluated by comparing its output to manually scored files from 6 rats under 2 experimental conditions by 3 users. Each user generated a training file, set thresholds, and autoscored the 12 files into 4 states (waking, non-REM, transition-to-REM, and REM sleep) in ¼ the time required to manually score the file. Overall performance comparisons between Auto-Scorer and manual scoring resulted in a mean agreement of 80.24 +/− 7.87%, comparable to the average agreement among 3 manual scorers (83.03 +/− 4.00%). There was no significant difference between user-user and user-Auto-Scorer agreement ratios. These results support the use of our open-source Auto-Scorer, coupled with user review, to rapidly and accurately score sleep/waking states from rat recordings. PMID:19615408
Bardach, Naomi S; Asteria-Peñaloza, Renée; Boscardin, W John; Dudley, R Adams
2013-03-01
Our goal was to compare hospital scores from the most widely used commercial website in the USA to hospital scores from more systematic measures of patient experience and outcomes, and to assess what drives variation in the commercial website scores. For a national sample of US hospitals, we compared scores on Yelp.com, which aggregates website visitor ratings (1-5 stars), with traditional measures of hospital quality. We calculated correlations between hospital Yelp scores and the following: hospital percent high ratings (9 or 10, scale 0-10) on the 'Overall' item on the Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) survey; hospital individual HCAHPS domain scores (eg, nurse communication, pain control); hospital 30-day mortality; and hospital 30-day readmission rates. Of hospitals reporting HCAHPS (n=3796), 962 (25%) had scores on Yelp. Among hospitals with >5 Yelp ratings, the correlation of percent high ratings between Yelp and HCAHPS was 0.49 (p<0.001). The percent high ratings within each HCAHPS domain increased monotonically with increasing Yelp scores (p≤0.001 for all domains). Percent high ratings in Yelp and HCAHPS were statistically significantly correlated with lower mortality for myocardial infarction (MI; -0.19 for Yelp and -0.13 for HCAHPS) and pneumonia (-0.14 and -0.18), and fewer readmissions for MI (-0.17 and -0.39), heart failure (-0.31 and -0.39), and pneumonia (-0.18 and -0.27). These data suggest that rater experiences for Yelp and HCAHPS may be similar, and that consumers posting ratings on Yelp may observe aspects of care related to important patient outcomes.
Ayaki, Masahiko; Negishi, Kazuno; Suzukamo, Yoshimi; Tsubota, Kazuo
2015-04-01
This study compared post-operative quality of life and sleep according to the type of cataract opacity and color of the implanted intra-ocular lens (IOL). This is a cohort study and participants were 206 patients (average age 74.1 years) undergoing cataract surgery with the implantation of a clear ultra-violet (UV)-blocking IOL (C) or a yellow blue-light-blocking IOL (Y). Participants were evaluated using the National Eye Institute Visual Function Questionnaire (VFQ-25) and Pittsburgh Sleep Quality Index (PSQI) before surgery and 2 and 7 months after surgery. Changes in sub-scale scores of VFQ-25 and PSQI were compared. Sub-scale analyses for improvement after surgery revealed significant differences in ocular pain scores on the VFQ-25 (Y>C; the higher the score, the better the outcome). Furthermore, there were significant differences between the two IOLs in terms of the sleep latency score (C>Y) and sleep disturbances score (C>Y). A posterior sub-capsular cataract was significantly correlated with improvements in ocular pain and sleep latency scores. These effects were successfully represented by the change in scores rather than absolute post-operative scores because individual standard of response may often change after intervention, recognized as a response shift phenomenon in patient-reported outcome study. Regarding seasonal differences, patients who had surgery in summer exhibited relatively better sleep quality than those who had surgery in winter. Analysis of sub-scales of health indices demonstrated characteristic prognoses for each IOL and cataract type. Cataract surgery may potentially contribute to systemic health in older adults.
Donoghue, Aaron; Ventre, Kathleen; Boulet, John; Brett-Fleegler, Marisa; Nishisaki, Akira; Overly, Frank; Cheng, Adam
2011-04-01
Robustly tested instruments for quantifying clinical performance during pediatric resuscitation are lacking. Examining Pediatric Resuscitation Education through Simulation and Scripting Collaborative was established to conduct multicenter trials of simulation education in pediatric resuscitation, evaluating performance with multiple instruments, one of which is the Clinical Performance Tool (CPT). We hypothesize that the CPT will measure clinical performance during simulated pediatric resuscitation in a reliable and valid manner. Using a pediatric resuscitation scenario as a basis, a scoring system was designed based on Pediatric Advanced Life Support algorithms comprising 21 tasks. Each task was scored as follows: task not performed (0 points); task performed partially, incorrectly, or late (1 point); and task performed completely, correctly, and within the recommended time frame (2 points). Study teams at 14 children's hospitals went through the scenario twice (PRE and POST) with an interposed 20-minute debriefing. Both scenarios for each of eight study teams were scored by multiple raters. A generalizability study, based on the PRE scores, was conducted to investigate the sources of measurement error in the CPT total scores. Inter-rater reliability was estimated based on the variance components. Validity was assessed by repeated measures analysis of variance comparing PRE and POST scores. Sixteen resuscitation scenarios were reviewed and scored by seven raters. Inter-rater reliability for the overall CPT score was 0.63. POST scores were found to be significantly improved compared with PRE scores when controlled for within-subject covariance (F1,15 = 4.64, P < 0.05). The variance component ascribable to rater was 2.4%. Reliable and valid measures of performance in simulated pediatric resuscitation can be obtained from the CPT. Future studies should examine the applicability of trichotomous scoring instruments to other clinical scenarios, as well as performance during actual resuscitations.
Avanesov, Maxim; Weinrich, Julius M; Kraus, Thomas; Derlin, Thorsten; Adam, Gerhard; Yamamura, Jin; Karul, Murat
2016-11-01
The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48-64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p=0.25; mCTSI: 4.0 vs. 4.0, p=0.10; EPIC: 2.0 vs. 2.0, p=0.41; NP: CTSI: 8.0 vs. 7.0, p=0.64; mCTSI: 8.0 vs. 8.0, p=0.10; EPIC: 3.0 vs. 3.0, p=0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. An initial dual-phase abdominal CT after ≥72h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a single-phase protocol. Copyright © 2016. Published by Elsevier Ireland Ltd.
Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L
2014-12-01
The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.
Mhlanga, Joyce C.; Carrino, John A.; Lodge, Martin; Wang, Hao
2015-01-01
Purpose The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18F-FDG. Methods Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Results Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73±7.7 years). Six patients served as the control group (53.7±9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r=0.86. p =0.007; r=0.94, p=0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7±6.6 vs. 32.2±0.4, p=0.02; 37.5±5.4 vs. 32.2±0.4, p=0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8±4.2 vs. 18±1.8, p= 0.13; 22.8±5.38 vs. 20.1±1.54, p=0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9±31.3 vs. 0, p=0.03). Conclusion Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. PMID:25134669
Chuang, Jung-Fang; Rau, Cheng-Shyuan; Kuo, Pao-Jen; Chen, Yi-Chun; Hsu, Shiun-Yuan; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2016-03-18
The adverse impact of obesity has been extensively studied in the general population; however, the added risk of obesity on trauma-related mortality remains controversial. This study investigated and compared mortality as well injury patterns and length of stay (LOS) in obese and normal-weight patients hospitalized for trauma in the hospital and intensive care unit (ICU) of a Level I trauma center in southern Taiwan. Detailed data of 880 obese adult patients with body mass index (BMI) ≥ 30 kg/m(2) and 5391 normal-weight adult patients (25 > BMI ≥ 18.5 kg/m(2)) who had sustained a trauma injury between January 1, 2009 and December 31, 2013 were retrieved from the Trauma Registry System. Pearson's chi-squared, Fisher's exact, and independent Student's t-tests were used to compare differences between groups. Propensity score matching with logistic regression was used to evaluate the effect of obesity on mortality. In this study, obese patients were more often men, motorcycle riders and pedestrians, and had a lower proportion of alcohol intoxication compared to normal-weight patients. Analysis of Abbreviated Injury Scale scores revealed that obese trauma patients presented with a higher rate of injury to the thorax, but a lower rate of facial injuries than normal-weight patients. No significant differences were found between obese and normal-weight patients regarding Injury Severity Score (ISS), Trauma-Injury Severity Score (TRISS), mortality, the proportion of patients admitted to the ICU, or LOS in ICU. After propensity score matching, logistic regression of 66 well-matched pairs did not show a significant influence of obesity on mortality (odds ratio: 1.51, 95% confidence interval: 0.54-4.23 p = 0.438). However, significantly longer hospital LOS (10.6 vs. 9.5 days, respectively, p = 0.044) was observed in obese patients than in normal-weight patients, particularly obese patients with pelvic, tibial, or fibular fractures. Compared to normal-weight patients, obese patients presented with different injury characteristics and bodily injury patterns but no difference in mortality.
ERIC Educational Resources Information Center
Marion, John M.
2011-01-01
In recent years technology has been integrated into every sector of education. Using Student Online Assessment Reporting System (SOARS) to assess score results and design instructional strategies for improved learning is a challenge and will cause concern to teachers. This is a descriptive comparative study designed to measure select Middle…
ERIC Educational Resources Information Center
Kavadias, Dimokritos; Hemmerechts, Kenneth; Spruyt, Bram
2017-01-01
Purpose: There is a tendency to assess educational systems in terms of their efficiency in gaining high scores on cognitive skills. Schools perform, however, also a socializing function. The whole policy debate tends to ignore the impact of educational systems on attitudes or democratic values. This contribution focuses on the impact of the…
Comparing Validity Evidence of Two ECERS-R Scoring Systems
ERIC Educational Resources Information Center
Zeng, Songtian
2017-01-01
Over 30 states have adopted the Early Childhood Environmental Rating Scale-Revised (ECERS-R) as a component of their program quality assessment systems, but the use of ECERS-R on such a large scale has raised important questions about implementation. One of the most pressing question centers upon decisions users must make between two scoring…
Flipping an Algebra Classroom: Analyzing, Modeling, and Solving Systems of Linear Equations
ERIC Educational Resources Information Center
Kirvan, Rebecca; Rakes, Christopher R.; Zamora, Regie
2015-01-01
The present study investigated whether flipping an algebra classroom led to a stronger focus on conceptual understanding and improved learning of systems of linear equations for 54 seventh- and eighth-grade students using teacher journal data and district-mandated unit exam items. Multivariate analysis of covariance was used to compare scores on…
Keller, San; Yang, Manshu; Treadwell, Marsha J; Hassell, Kathryn L
2017-06-02
Sickle Cell Disease (SCD) causes profound suffering and decrements in daily functioning. Demand is growing for valid and reliable measures to systematically document these effects, particularly in adults. The Adult Sickle Cell Quality of Life Measurement System, ASCQ-Me℠, was developed for this purpose. ASCQ-Me℠ is one of four measurement systems housed within the Person-Centered Assessment Resource (PCAR), funded by the National Institutes of Health, to support clinical research. To help users select the best of these measures for adults with SCD, we evaluated and compared two PCAR systems: one designed to be "universally applicable" (the Patient-Reported Outcome Measurement Information System, PROMIS®) and one designed specifically for SCD (ASCQ-Me℠). Respondents to PROMIS and ASCQ-Me questions were 490 adults with SCD from seven geographically-disbursed clinics within the US. Data were collected for six ASCQ-Me measures (Emotional Impact, Sleep Impact, Social Impact, Stiffness Impact, Pain Impact, SCD Pain Episode Frequency and Severity) and ten PROMIS measures (Pain Impact, Pain Behavior, Physical Functioning, Anxiety, Depression, Fatigue, Satisfaction with Discretionary Social Activities, Satisfaction with Social Roles, Sleep Disturbance, and Sleep-Related Impairment). Statistical analyses, including analysis of variance and multiple linear regression, were conducted to determine the sensitivity of measures to SCD severity. SCD severity was assessed via a checklist of associated treatments and conditions. For those with the most severe SCD, PROMIS scores showed worse health compared to the general population for nine of ten health domains: the magnitude of the difference ranged 0.5 to 1.1 standard deviation units. The PROMIS domains most severely affected were Physical Functioning and Pain (Impact and Behavior). Significant differences by tertile of the SCD-MHC were shown for most PROMIS short forms and all ASCQ-Me short and fixed forms. In most models, ASCQ-Me measures explained statistically significant unique variance in SCD-MHC scores complementary to that explained by corresponding PROMIS measures. Study results supported the validity of both PROMIS and ASCQ-Me measures for use in adults with SCD. Compared to comparable PROMIS scores, most ASCQ-Me scores were better predictors of SCD disease severity, as measured by a medical history checklist. The clinical implications of these results require further investigation.
Effects of anti-tumour necrosis factor-alpha therapy on the quality of life in Crohn's disease.
van Balkom, B P J; Schoon, E J; Stockbrügger, R W; Wolters, F L; van Hogezand, R A; van Deventer, S J H; Oldenburg, B; van Dullemen, H M; Russel, M G V M
2002-06-01
Infusion of anti-tumour necrosis factor-alpha appears to be highly effective in patients with Crohn's disease. To assess the effect of infliximab on the quality of life in patients with active or fistulizing disease, as measured by the inflammatory bowel disease questionnaire, and to examine the impact on its four dimensions. An observational study was conducted in 65 patients. An infusion of 5 mg/kg infliximab was given at week 0 in patients with active disease and at week 0, 2 and 6 in fistulizing disease. Changes from baseline in the total and dimensional inflammatory bowel disease questionnaire scores were calculated and compared between the patient groups. Potential predictors of change in the quality of life were identified. In the active disease group, at week 4, the mean total and dimensional inflammatory bowel disease questionnaire scores improved compared to baseline (P < 0.001). In the fistulizing group, at week 6, all scores changed from baseline (P < 0.05). Improvement in the total inflammatory bowel disease questionnaire score correlated well with the improvement of the Crohn's disease activity index. Systemic and social scores improved more than bowel and emotional scores. Inflammatory Crohn's disease and a young age at diagnosis were predictors for a better response to infliximab therapy. Infliximab therapy improves all dimensions of the quality of life in patients with Crohn's disease.
Matsuzaki, Juntaro; Okada, Sawako; Hirata, Kenro; Fukuhara, Seiichiro; Hibi, Toshifumi
2013-01-01
Background The GerdQ scoring system may be a useful tool for managing gastro-oesophageal reflux disease. However, GerdQ has not been fully validated in Asian countries. Objective To validate the Japanese version of GerdQ and to compare this version to the Carlsson-Dent questionnaire (CDQ) in both general and hospital-based populations. Methods The questionnaires, including the Japanese versions of GerdQ and CDQ, and questions designed to collect demographic information, were sent to a general population via the web, and to a hospital-based population via conventional mail. The optimal cutoff GerdQ score and the differences in the characteristics between GerdQ and CDQ were assessed. Results The answers from 863 web-responders and 303 conventional-mail responders were analysed. When a GerdQ cutoff score was set at 8, GerdQ significantly predicted the presence of reflux oesophagitis. Although the GerdQ scores were correlated with the CDQ scores, the concordance rates were poor. Multivariate analysis results indicated that, the additional use of over-the-counter medications was associated with GerdQ score ≥ 8, but not with CDQ score ≥ 6. Conclusions The GerdQ cutoff score of 8 was appropriate for the Japanese population. Compared with CDQ, GerdQ was more useful for evaluating treatment efficacy and detecting patients’ unmet medical needs. PMID:24917957
Adachi, Naoto; Hirota, Masahiko; Hamaguchi, Masamichi; Okamoto, Kazufumi; Watanabe, Keisuke; Endo, Fumio
2004-04-01
Apoptosis may play an important role in the development of systemic inflammatory response syndrome (SIRS) and progression to multiple organ dysfunction syndrome (MODS). To quantify the extent of apoptosis in these morbidities, we developed a sandwich ELISA system to measure serum cytochrome c (cyt-c) levels and we investigated the prognostic significance of cyt-c concentration in SIRS/MODS patients. Cyt-c concentrations in patients with SIRS (n=53) with or at risk for MODS were measured and compared with those of control subjects (n=14). Cyt-c concentrations in SIRS/MODS patients increased (0.24-210 ng/ml), whereas those in control subjects were under detection limits (0.1 ng/ml). Cyt-c concentrations in non-survivors increased significantly compared with those in survivors both on the day of admission and on the fifth hospital day. A significant positive correlation was found between cyt-c concentration and two representative organ dysfunction scores, APACHE II and multi-organ failure (MOF) score. Cyt-c concentrations increased earlier than MOF score during the exacerbation phase and rapidly decreased during the convalescence phase in a survivor, but the level continued to be high in a non-survivor. Determination of serum cyt-c concentrations may be useful to assess the severity of organ dysfunction and to predict the prognosis of SIRS/MODS patients.
Buerkle, Bernd; Pueth, Julia; Hefler, Lukas A; Tempfer-Bentz, Eva-Katrin; Tempfer, Clemens B
2012-10-01
To compare the skills of performing a shoulder dystocia management algorithm after hands-on training compared with demonstration. We randomized medical students to a 30-minute hands-on (group 1) and a 30-minute demonstration (group 2) training session teaching a standardized shoulder dystocia management scheme on a pelvic training model. Participants were tested with a 22-item Objective Structured Assessment of Technical Skills scoring system after training and 72 hours thereafter. Objective Structured Assessment of Technical Skills scores were the primary outcome. Performance time, self-assessment, confidence, and global rating scale were the secondary outcomes. Statistics were performed using Mann-Whitney U test, χ test, and multiple linear regression analysis. Two hundred three participants were randomized. Objective Structured Assessment of Technical Skills scores were significantly higher in group 1 (n=103) compared with group 2 (n=100) (17.95±3.14 compared with 15.67±3.18, respectively; P<.001). The secondary outcomes global rating scale (GRS; 10.94±2.71 compared with 8.57±2.61, respectively; P<.001), self-assessment (3.15±0.94 compared with 2.72±1.01; P=.002), and confidence (3.72±0.98 compared with 3.34±0.90, respectively; P=.005), but not performance time (3:19±0:48 minutes compared with 3:31±1:05 minutes; P=.1), were also significantly different, favoring group 1. After 72 hours, Objective Structured Assessment of Technical Skills scores were still significantly higher in group 1 (n=67) compared with group 2 (n=60) (18.17±2.76 compared with 14.98±3.03, respectively; P<.001) as were GRS (10.80±2.62 compared with 8.15±2.59; P<.001) and self assessment (SA; 3.44±0.87 compared with 2.95±0.94; P=.003). In a multiple linear regression analysis, group assignment (group 1 compared with 2; P<.001) and sex (P=.002) independently influenced Objective Structured Assessment of Technical Skills scores. Hands-on training helps to achieve a significant improvement of shoulder dystocia management on a pelvic training model. www.ClinicalTrials.gov, NCT01618565. I.
Tsigginou, Alexandra; Chalazonitis, Athanasios; Feida, Eleni; Vlachos, Dimitrios Efthymios; Zagouri, Flora; Rellias, Ioannis; Dimitrakakis, Constantine
2016-01-01
Dual-energy contrast-enhanced spectral mammography (CESM) represents a relatively new diagnostic tool adjunct to mammography. The aim of this study was to strengthen the breast imaging-reporting and data system (BIRADS) classification score in order to improve early breast cancer diagnosis. For this reason, we propose a sum score, termed malignancy potential score (MPS), incorporating the standard BIRADS score and our proposed CESM score. From September 2014 to September 2015, 216 females (age range, 26–85 years; mean age 54.6 years) underwent CESM evaluation of mammographic findings that were primarily assessed as BIRADS 2–5. 10 of these patients had bilateral findings; a total of 226 lesions were examined. High-energy image evaluation was based on the intensity of contrast enhancement of the lesion compared with background enhancement, categorized as Type -1, 0, 1 or 2 enhancement. Histopathology reports were compared with imaging assessment. 98 of 226 lesions were malignant and 128 of 226 lesions were benign. The area under the curve was 0.843, 0.888 and 0.917 for mammographic BIRADS score, CESM score and MPS, respectively, with p-value < 0.05. The sensitivity, specificity and accuracy rates were 91.83, 80.47 and 85.40%, respectively, when a best MPS cut-off point of 4 was used. The malignancy potential score (MPS) has higher diagnostic performance than digital mammography or CESM alone. MPS empowers the credibility of the digital mammography BIRADS score and our proposed type of enhancement in dual-energy CESM and is a diagnostic tool that increases the accuracy rate in early breast cancer diagnosis. PMID:27452266
Reliability of sonographic assessment of tendinopathy in tennis elbow.
Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim
2012-01-01
To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.
Psychological consequences in pediatric intensive care unit survivors: the neglected outcome.
Muranjan, Mamta N; Birajdar, Suresh B; Shah, Henal R; Sundaraman, Preeti; Tullu, Milind S
2008-02-01
To determine whether Pediatric Intensive Care Unit (PICU) hospitalization results in adverse psychological effects and to identify the contributory factors. Level III PICU of a tertiary center. Prospective cohort study. Consecutive patients 5 years or older admitted to PICU for at least 48 hours constituted the study population. Controls were age and sex matched children hospitalized in the pediatric wards for at least 48 hours. Severity of illness was assessed by the Pediatric Risk of Mortality (PRISM) score. Level of therapeutic intervention was determined by the Therapeutic Interventions Scoring System (TISS--76 score). Temperament Measurement Schedule was used to assess the premorbid temperament. Psychological assessment was performed using Impact of Event Scale (IES), Birleson Depression Scale and the Self-Esteem Scale. Follow-up evaluation was done one month after discharge. There were 30 children each in the study and control groups. They had comparable pre-morbid temperament as well as scores on the self-esteem and depression scales. Significantly higher proportion of patients in PICU had intrusive thoughts (43%) as compared to controls (6.7%). Development of intrusive thoughts correlated significantly with the degree of intervention. Demographic parameters, nature of the disease, duration of hospitalization and severity of illness did not correlate with the psychological outcome. One month after discharge, scores in both groups were comparable. Children subjected to therapeutic interventions in the PICU develop transient psychological impairment manifested by experiencing intrusive thoughts that resolve within a month.
Dasari, Surendra; Chambers, Matthew C.; Martinez, Misti A.; Carpenter, Kristin L.; Ham, Amy-Joan L.; Vega-Montoto, Lorenzo J.; Tabb, David L.
2012-01-01
Spectral libraries have emerged as a viable alternative to protein sequence databases for peptide identification. These libraries contain previously detected peptide sequences and their corresponding tandem mass spectra (MS/MS). Search engines can then identify peptides by comparing experimental MS/MS scans to those in the library. Many of these algorithms employ the dot product score for measuring the quality of a spectrum-spectrum match (SSM). This scoring system does not offer a clear statistical interpretation and ignores fragment ion m/z discrepancies in the scoring. We developed a new spectral library search engine, Pepitome, which employs statistical systems for scoring SSMs. Pepitome outperformed the leading library search tool, SpectraST, when analyzing data sets acquired on three different mass spectrometry platforms. We characterized the reliability of spectral library searches by confirming shotgun proteomics identifications through RNA-Seq data. Applying spectral library and database searches on the same sample revealed their complementary nature. Pepitome identifications enabled the automation of quality analysis and quality control (QA/QC) for shotgun proteomics data acquisition pipelines. PMID:22217208
Minefield reconnaissance and detector system
Butler, Millard T.; Cave, Steven P.; Creager, James D.; Johnson, Charles M.; Mathes, John B.; Smith, Kirk J.
1994-01-01
A multi-sensor system (10) for detecting the presence of objects on the surface of the ground or buried just under the surface, such as anti-personnel or anti-tank mines or the like. A remote sensor platform (12) has a plurality of metal detector sensors (22) and a plurality of short pulse radar sensors (24). The remote sensor platform (12) is remotely controlled from a processing and control unit (14) and signals from the remote sensor platform (12) are sent to the processing and control unit (14) where they are individually evaluated in separate data analysis subprocess steps (34, 36) to obtain a probability "score" for each of the pluralities of sensors (22, 24). These probability scores are combined in a fusion subprocess step (38) by comparing score sets to a probability table (130) which is derived based upon the historical incidence of object present conditions given that score set. A decision making rule is applied to provide an output which is optionally provided to a marker subprocess (40) for controlling a marker device (76) to mark the location of found objects.
Sadlik, Boguslaw; Puszkarz, Mariusz; Kosmalska, Lidia; Wiewiorski, Martin
2017-11-01
The technique of all-arthroscopic autologous matrix-induced chondrogenesis (AMIC)-aided repair of patellar cartilage lesions using a retraction system and dry arthroscopy has been recently described. We report the first clinical and radiological data at a short-term follow-up. Twelve patients underwent AMIC-aided cartilage repair for a patellar lesion. All steps of the procedure were performed arthroscopically, which include the use of an intra-articularly placed retraction plate for distraction of the patellofemoral joint and evacuation of saline solution for collagen matrix insertion and fixation. Clinical assessment performed before surgery and at a mean follow-up time of 38 months (range: 24-70) included the following scores: Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC), and visual analog scale (VAS). Magnetic resonance imaging was performed at the follow-up examination, including the magnetic resonance observation of cartilage repair tissue (MOCART) score. The mean KOOS and IKDC scores increased significantly ( p < 0.01) from 50.3 and 37.4 points preoperatively to 90.1 and 79.4 postoperatively. The VAS score decreased from 7.8 to 2.3 points. Mean MOCART score at follow-up was 58.3 points. Cartilage repair of patellar lesions aided by a retraction system in a dry arthroscopy setup is a promising approach. Further studies are needed to evaluate this procedure and compare it to existing matrix implantation techniques. The level of evidence for the study is 4 (case series). Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Revisiting the rotating call schedule in less than 80 hours per week.
Roses, Robert E; Foley, Paul J; Paulson, Emily C; Pray, Lori; Kelz, Rachel R; Williams, Noel N; Morris, Jon B
2009-01-01
The Accreditation Council for Graduate Medical Education (ACGME) work-hour restrictions have prompted many surgical training programs to adopt a night-float resident coverage system (NF). Dissatisfaction with NF prompted us to transition to a rotating junior resident call model (Q4) with 24-hour call shifts at the outset of the 2007-2008 academic year. We performed a prospective study to determine the influence of this transition on resident education, morale, and quality of life, as well as on ACGME work rule compliance and American Board of Surgery In-Training Examination (ABSITE) scores. Residents were surveyed after 1 year of NF and again 1 year after the introduction of Q4. Responses to a series of statements about the influence of the call model (NF or Q4) on educational opportunities and morale were solicited. The survey used a 5-point Likert response scale (1 = complete disagreement to 5 = complete agreement). Median values of participant responses were calculated and compared using the Wilcoxon rank-sum test. Compliance with ACGME work rules, ABSITE scores, and operative case logs from the 2006-2007 and 2007-2008 academic years were also compared. Residents were significantly more enthusiastic about Q4 compared with NF, particularly when asked about the influence these systems had on morale (median response = 4.0 [Q4] compared with 2.0 [NF]; p = 0.001) and engagement of residents by the teaching faculty (median response = 4.0 [Q4] compared with 1.0 [NF]; p = 0.001). Case logs revealed a similar operative experience for first-year residents irrespective of the call schedule (p = 0.51). Excellent compliance with ACGME work rules was maintained as reflected by the percentage of monthly 80-hour violations per resident months worked (3% [Q4] compared with 0.7% [NF]). No difference was observed in the ABSITE scores of first-year residents (a mean percentile point increase of 1 was found after the introduction of Q4). Educational opportunities, compliance with ACGME work rules, and ABSITE scores can be preserved despite a transition from NF to Q4. Residents greatly prefer a rotating call schedule.
The variability of software scoring of the CDMAM phantom associated with a limited number of images
NASA Astrophysics Data System (ADS)
Yang, Chang-Ying J.; Van Metter, Richard
2007-03-01
Software scoring approaches provide an attractive alternative to human evaluation of CDMAM images from digital mammography systems, particularly for annual quality control testing as recommended by the European Protocol for the Quality Control of the Physical and Technical Aspects of Mammography Screening (EPQCM). Methods for correlating CDCOM-based results with human observer performance have been proposed. A common feature of all methods is the use of a small number (at most eight) of CDMAM images to evaluate the system. This study focuses on the potential variability in the estimated system performance that is associated with these methods. Sets of 36 CDMAM images were acquired under carefully controlled conditions from three different digital mammography systems. The threshold visibility thickness (TVT) for each disk diameter was determined using previously reported post-analysis methods from the CDCOM scorings for a randomly selected group of eight images for one measurement trial. This random selection process was repeated 3000 times to estimate the variability in the resulting TVT values for each disk diameter. The results from using different post-analysis methods, different random selection strategies and different digital systems were compared. Additional variability of the 0.1 mm disk diameter was explored by comparing the results from two different image data sets acquired under the same conditions from the same system. The magnitude and the type of error estimated for experimental data was explained through modeling. The modeled results also suggest a limitation in the current phantom design for the 0.1 mm diameter disks. Through modeling, it was also found that, because of the binomial statistic nature of the CDMAM test, the true variability of the test could be underestimated by the commonly used method of random re-sampling.