Sample records for scoring systems based

  1. Similar predictions of etravirine sensitivity regardless of genotypic testing method used: comparison of available scoring systems.

    PubMed

    Vingerhoets, Johan; Nijs, Steven; Tambuyzer, Lotke; Hoogstoel, Annemie; Anderson, David; Picchio, Gaston

    2012-01-01

    The aims of this study were to compare various genotypic scoring systems commonly used to predict virological outcome to etravirine, and examine their concordance with etravirine phenotypic susceptibility. Six etravirine genotypic scoring systems were assessed: Tibotec 2010 (based on 20 mutations; TBT 20), Monogram, Stanford HIVdb, ANRS, Rega (based on 37, 30, 27 and 49 mutations, respectively) and virco(®)TYPE HIV-1 (predicted fold change based on genotype). Samples from treatment-experienced patients who participated in the DUET trials and with both genotypic and phenotypic data (n=403) were assessed using each scoring system. Results were retrospectively correlated with virological response in DUET. κ coefficients were calculated to estimate the degree of correlation between the different scoring systems. Correlation between the five scoring systems and the TBT 20 system was approximately 90%. Virological response by etravirine susceptibility was comparable regardless of which scoring system was utilized, with 70-74% of DUET patients determined as susceptible to etravirine by the different scoring systems achieving plasma viral load <50 HIV-1 RNA copies/ml. In samples classed as phenotypically susceptible to etravirine (fold change in 50% effective concentration ≤3), correlations with genotypic score were consistently high across scoring systems (≥70%). In general, the etravirine genotypic scoring systems produced similar results, and genotype-phenotype concordance was high. As such, phenotypic interpretations, and in their absence all genotypic scoring systems investigated, may be used to reliably predict the activity of etravirine.

  2. Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition

    PubMed Central

    Islam, Md. Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al. PMID:25114676

  3. Feature and score fusion based multiple classifier selection for iris recognition.

    PubMed

    Islam, Md Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  4. Slit Lamp-Based Ocular Scoring Systems in Toxicology and Drug Development: A Literature Survey.

    PubMed

    Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J

    2017-12-01

    To present a survey of the features of published slit lamp-based scoring systems and their applicability in the context of modern ocular toxicology and drug development. References describing original or modified slit lamp-based scoring systems for human or veterinary clinical patients or in investigative or toxicologic research were collected following a comprehensive literature review using textbooks and online publication searches. Each system's indications and features were compiled to facilitate comparison. Literature review identified 138 original or modified scoring systems. Most (48%) were published for evaluation of the ocular surface, 34% for the general anterior segment, and 18% for the lens. Most systems were described for assessment of human patients (50%) and small albino laboratory species such as rabbits (19%), rats (12%), and mice (8%). Systems described for pigmented laboratory species and for larger species such as dogs, cats, pigs, and nonhuman primates (NHPs) were comparatively underrepresented. No systems described a lens scoring scheme specific to the dog, cat, pig, or NHP. Scoring schemes for aqueous and vitreous cells were infrequently described for laboratory species. Many slit lamp-based scoring systems have been published, but the features of each differ and complicate translation of findings between different species. Use and interpretation of any scoring system in toxicology and drug development must be done with awareness of the limitations of the system being used.

  5. A new extranodal scoring system based on the prognostically relevant extranodal sites in diffuse large B-cell lymphoma, not otherwise specified treated with chemoimmunotherapy.

    PubMed

    Hwang, Hee Sang; Yoon, Dok Hyun; Suh, Cheolwon; Huh, Jooryung

    2016-08-01

    Extranodal involvement is a well-known prognostic factor in patients with diffuse large B-cell lymphomas (DLBCL). Nevertheless, the prognostic impact of the extranodal scoring system included in the conventional international prognostic index (IPI) has been questioned in an era where rituximab treatment has become widespread. We investigated the prognostic impacts of individual sites of extranodal involvement in 761 patients with DLBCL who received rituximab-based chemoimmunotherapy. Subsequently, we established a new extranodal scoring system based on extranodal sites, showing significant prognostic correlation, and compared this system with conventional scoring systems, such as the IPI and the National Comprehensive Cancer Network-IPI (NCCN-IPI). An internal validation procedure, using bootstrapped samples, was also performed for both univariate and multivariate models. Using multivariate analysis with a backward variable selection, we found nine extranodal sites (the liver, lung, spleen, central nervous system, bone marrow, kidney, skin, adrenal glands, and peritoneum) that remained significant for use in the final model. Our newly established extranodal scoring system, based on these sites, was better correlated with patient survival than standard scoring systems, such as the IPI and the NCCN-IPI. Internal validation by bootstrapping demonstrated an improvement in model performance of our modified extranodal scoring system. Our new extranodal scoring system, based on the prognostically relevant sites, may improve the performance of conventional prognostic models of DLBCL in the rituximab era and warrants further external validation using large study populations.

  6. An update on risk factors for cartilage loss in knee osteoarthritis assessed using MRI-based semiquantitative grading methods.

    PubMed

    Alizai, Hamza; Roemer, Frank W; Hayashi, Daichi; Crema, Michel D; Felson, David T; Guermazi, Ali

    2015-03-01

    Arthroscopy-based semiquantitative scoring systems such as Outerbridge and Noyes' scores were the first to be developed for the purpose of grading cartilage defects. As magnetic resonance imaging (MRI) became available for evaluation of the osteoarthritic knee joint, these systems were adapted for use with MRI. Later on, grading methods such as the Whole Organ Magnetic Resonance Score, the Boston-Leeds Osteoarthritis Knee Score and the MRI Osteoarthritis Knee Score were designed specifically for performing whole-organ assessment of the knee joint structures, including cartilage. Cartilage grades on MRI obtained with these scoring systems represent optimal outcome measures for longitudinal studies, and are designed to enhance understanding of the knee osteoarthritis disease process. The purpose of this narrative review is to describe cartilage assessment in knee osteoarthritis using currently available MRI-based semiquantitative whole-organ scoring systems, and to provide an update on the risk factors for cartilage loss in knee osteoarthritis as assessed with these scoring systems.

  7. Estimation of a Preference-Based Summary Score for the Patient-Reported Outcomes Measurement Information System: The PROMIS®-Preference (PROPr) Scoring System.

    PubMed

    Dewitt, Barry; Feeny, David; Fischhoff, Baruch; Cella, David; Hays, Ron D; Hess, Rachel; Pilkonis, Paul A; Revicki, Dennis A; Roberts, Mark S; Tsevat, Joel; Yu, Lan; Hanmer, Janel

    2018-06-01

    Health-related quality of life (HRQL) preference-based scores are used to assess the health of populations and patients and for cost-effectiveness analyses. The National Institutes of Health Patient-Reported Outcomes Measurement Information System (PROMIS ® ) consists of patient-reported outcome measures developed using item response theory. PROMIS is in need of a direct preference-based scoring system for assigning values to health states. To produce societal preference-based scores for 7 PROMIS domains: Cognitive Function-Abilities, Depression, Fatigue, Pain Interference, Physical Function, Sleep Disturbance, and Ability to Participate in Social Roles and Activities. Online survey of a US nationally representative sample ( n = 983). Preferences for PROMIS health states were elicited with the standard gamble to obtain both single-attribute scoring functions for each of the 7 PROMIS domains and a multiplicative multiattribute utility (scoring) function. The 7 single-attribute scoring functions were fit using isotonic regression with linear interpolation. The multiplicative multiattribute summary function estimates utilities for PROMIS multiattribute health states on a scale where 0 is the utility of being dead and 1 the utility of "full health." The lowest possible score is -0.022 (for a state viewed as worse than dead), and the highest possible score is 1. The online survey systematically excludes some subgroups, such as the visually impaired and illiterate. A generic societal preference-based scoring system is now available for all studies using these 7 PROMIS health domains.

  8. Effectiveness of Automated Chinese Sentence Scoring with Latent Semantic Analysis

    ERIC Educational Resources Information Center

    Liao, Chen-Huei; Kuo, Bor-Chen; Pai, Kai-Chih

    2012-01-01

    Automated scoring by means of Latent Semantic Analysis (LSA) has been introduced lately to improve the traditional human scoring system. The purposes of the present study were to develop a LSA-based assessment system to evaluate children's Chinese sentence construction skills and to examine the effectiveness of LSA-based automated scoring function…

  9. Spatial clustering of pixels of a multispectral image

    DOEpatents

    Conger, James Lynn

    2014-08-19

    A method and system for clustering the pixels of a multispectral image is provided. A clustering system computes a maximum spectral similarity score for each pixel that indicates the similarity between that pixel and the most similar neighboring. To determine the maximum similarity score for a pixel, the clustering system generates a similarity score between that pixel and each of its neighboring pixels and then selects the similarity score that represents the highest similarity as the maximum similarity score. The clustering system may apply a filtering criterion based on the maximum similarity score so that pixels with similarity scores below a minimum threshold are not clustered. The clustering system changes the current pixel values of the pixels in a cluster based on an averaging of the original pixel values of the pixels in the cluster.

  10. Application of a computed tomography based cystic fibrosis scoring system to chest tomosynthesis

    NASA Astrophysics Data System (ADS)

    Söderman, Christina; Johnsson, Åse; Vikgren, Jenny; Rystedt, Hans; Ivarsson, Jonas; Rossi Norrlund, Rauni; Nyberg Andersson, Lena; Bâth, Magnus

    2013-03-01

    In the monitoring of progression of lung disease in patients with cystic fibrosis (CF), recurrent computed tomography (CT) examinations are often used. The relatively new imaging technique chest tomosynthesis (CTS) may be an interesting alternative in the follow-up of these patients due to its visualization of the chest in slices at radiation doses and costs significantly lower than is the case with CT. A first step towards introducing CTS imaging in the diagnostics of CF patients is to establish a scoring system appropriate for evaluating the severity of CF pulmonary disease based on findings in CTS images. Previously, several such CF scoring systems based on CT imaging have been published. The purpose of the present study was to develop a CF scoring system for CTS, by starting from an existing scoring system dedicated for CT images and making modifications regarded necessary to make it appropriate for use with CTS images. In order to determine any necessary changes, three thoracic radiologists independently used a scoring system dedicated for CT on both CT and CTS images from CF patients. The results of the scoring were jointly evaluated by all the observers, which lead to suggestions for changes to the scoring system. Suggested modifications include excluding the scoring of air trapping and doing the scoring of the findings in quadrants of the image instead of in each lung lobe.

  11. Developing points-based risk-scoring systems in the presence of competing risks.

    PubMed

    Austin, Peter C; Lee, Douglas S; D'Agostino, Ralph B; Fine, Jason P

    2016-09-30

    Predicting the occurrence of an adverse event over time is an important issue in clinical medicine. Clinical prediction models and associated points-based risk-scoring systems are popular statistical methods for summarizing the relationship between a multivariable set of patient risk factors and the risk of the occurrence of an adverse event. Points-based risk-scoring systems are popular amongst physicians as they permit a rapid assessment of patient risk without the use of computers or other electronic devices. The use of such points-based risk-scoring systems facilitates evidence-based clinical decision making. There is a growing interest in cause-specific mortality and in non-fatal outcomes. However, when considering these types of outcomes, one must account for competing risks whose occurrence precludes the occurrence of the event of interest. We describe how points-based risk-scoring systems can be developed in the presence of competing events. We illustrate the application of these methods by developing risk-scoring systems for predicting cardiovascular mortality in patients hospitalized with acute myocardial infarction. Code in the R statistical programming language is provided for the implementation of the described methods. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  12. Optimal protein library design using recombination or point mutations based on sequence-based scoring functions.

    PubMed

    Pantazes, Robert J; Saraf, Manish C; Maranas, Costas D

    2007-08-01

    In this paper, we introduce and test two new sequence-based protein scoring systems (i.e. S1, S2) for assessing the likelihood that a given protein hybrid will be functional. By binning together amino acids with similar properties (i.e. volume, hydrophobicity and charge) the scoring systems S1 and S2 allow for the quantification of the severity of mismatched interactions in the hybrids. The S2 scoring system is found to be able to significantly functionally enrich a cytochrome P450 library over other scoring methods. Given this scoring base, we subsequently constructed two separate optimization formulations (i.e. OPTCOMB and OPTOLIGO) for optimally designing protein combinatorial libraries involving recombination or mutations, respectively. Notably, two separate versions of OPTCOMB are generated (i.e. model M1, M2) with the latter allowing for position-dependent parental fragment skipping. Computational benchmarking results demonstrate the efficacy of models OPTCOMB and OPTOLIGO to generate high scoring libraries of a prespecified size.

  13. Prognostic scoring systems for myelodysplastic syndromes (MDS) in a population-based setting: a report from the Swedish MDS register.

    PubMed

    Moreno Berggren, Daniel; Folkvaljon, Yasin; Engvall, Marie; Sundberg, Johan; Lambe, Mats; Antunovic, Petar; Garelius, Hege; Lorenz, Fryderyk; Nilsson, Lars; Rasmussen, Bengt; Lehmann, Sören; Hellström-Lindberg, Eva; Jädersten, Martin; Ejerblad, Elisabeth

    2018-06-01

    The myelodysplastic syndromes (MDS) have highly variable outcomes and prognostic scoring systems are important tools for risk assessment and to guide therapeutic decisions. However, few population-based studies have compared the value of the different scoring systems. With data from the nationwide Swedish population-based MDS register we validated the International Prognostic Scoring System (IPSS), revised IPSS (IPSS-R) and the World Health Organization (WHO) Classification-based Prognostic Scoring System (WPSS). We also present population-based data on incidence, clinical characteristics including detailed cytogenetics and outcome from the register. The study encompassed 1329 patients reported to the register between 2009 and 2013, 14% of these had therapy-related MDS (t-MDS). Based on the MDS register, the yearly crude incidence of MDS in Sweden was 2·9 per 100 000 inhabitants. IPSS-R had a significantly better prognostic power than IPSS (P < 0·001). There was a trend for better prognostic power of IPSS-R compared to WPSS (P = 0·05) and for WPSS compared to IPSS (P = 0·07). IPSS-R was superior to both IPSS and WPSS for patients aged ≤70 years. Patients with t-MDS had a worse outcome compared to de novo MDS (d-MDS), however, the validity of the prognostic scoring systems was comparable for d-MDS and t-MDS. In conclusion, population-based studies are important to validate prognostic scores in a 'real-world' setting. In our nationwide cohort, the IPSS-R showed the best predictive power. © 2018 John Wiley & Sons Ltd.

  14. Automatic Dialogue Scoring for a Second Language Learning System

    ERIC Educational Resources Information Center

    Huang, Jin-Xia; Lee, Kyung-Soon; Kwon, Oh-Woog; Kim, Young-Kil

    2016-01-01

    This paper presents an automatic dialogue scoring approach for a Dialogue-Based Computer-Assisted Language Learning (DB-CALL) system, which helps users learn language via interactive conversations. The system produces overall feedback according to dialogue scoring to help the learner know which parts should be more focused on. The scoring measures…

  15. A Milestone-Based Evaluation System-The Cure for Grade Inflation?

    PubMed

    Kuo, Lindsay E; Hoffman, Rebecca L; Morris, Jon B; Williams, Noel N; Malachesky, Mark; Huth, Laura E; Kelz, Rachel R

    2015-01-01

    Controversy exists over the optimal use of the Milestones in the process of resident evaluation and feedback. We sought to evaluate the performance of a Milestones-based feedback system in comparison to a traditional model. The traditional evaluation system (TES) consisted of a generic 16-item survey using a 5-point Likert scale ranging from 1 to 5, and a free-text comments section. The Milestones-based evaluation system (MBES) was launched in July 2014, ranging from 0 to 4. Individual milestones were mapped to rotations based on resident educational goals by postgraduate year (PGY). The MBES consisted of a survey with a maximum of 7 items, followed by a free-text comment section. Within each evaluation system, an overall composite score was calculated for each categorical general surgical resident. To scale the 2 systems for comparison, TES scores were adjusted downward by 1 point. Descriptive statistics were performed. Univariate analysis was performed with the Wilcoxon signed-rank test. A test for trend across PGY was used for the MBES only. In the traditional system, the median score was 3.66 (range: 3.2-4.0). There was no meaningful difference in the median score by PGY. In the new system, the median score was 2.69 (range: 1.5-3.7, p < 0.01). The median score differed across PGY and increased by PGY of training (p < 0.01). There was an increase in differences between median scores by PGY. On using the milestones to facilitate faculty evaluation of resident knowledge and skill, there was a trend in increasing score by PGY of training. In the MBES, scores could be used to better discriminate resident skill and knowledge levels and resulted in improved differentiation in scoring by PGY. The use of the milestones as a basis for evaluation enabled the program to provide more meaningful feedback to residents and represents an improvement in surgical education. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Rating the methodological quality in systematic reviews of studies on measurement properties: a scoring system for the COSMIN checklist.

    PubMed

    Terwee, Caroline B; Mokkink, Lidwine B; Knol, Dirk L; Ostelo, Raymond W J G; Bouter, Lex M; de Vet, Henrica C W

    2012-05-01

    The COSMIN checklist is a standardized tool for assessing the methodological quality of studies on measurement properties. It contains 9 boxes, each dealing with one measurement property, with 5-18 items per box about design aspects and statistical methods. Our aim was to develop a scoring system for the COSMIN checklist to calculate quality scores per measurement property when using the checklist in systematic reviews of measurement properties. The scoring system was developed based on discussions among experts and testing of the scoring system on 46 articles from a systematic review. Four response options were defined for each COSMIN item (excellent, good, fair, and poor). A quality score per measurement property is obtained by taking the lowest rating of any item in a box ("worst score counts"). Specific criteria for excellent, good, fair, and poor quality for each COSMIN item are described. In defining the criteria, the "worst score counts" algorithm was taken into consideration. This means that only fatal flaws were defined as poor quality. The scores of the 46 articles show how the scoring system can be used to provide an overview of the methodological quality of studies included in a systematic review of measurement properties. Based on experience in testing this scoring system on 46 articles, the COSMIN checklist with the proposed scoring system seems to be a useful tool for assessing the methodological quality of studies included in systematic reviews of measurement properties.

  17. Accuracy and Efficiency of Recording Pediatric Early Warning Scores Using an Electronic Physiological Surveillance System Compared With Traditional Paper-Based Documentation.

    PubMed

    Sefton, Gerri; Lane, Steven; Killen, Roger; Black, Stuart; Lyon, Max; Ampah, Pearl; Sproule, Cathryn; Loren-Gosling, Dominic; Richards, Caitlin; Spinty, Jean; Holloway, Colette; Davies, Coral; Wilson, April; Chean, Chung Shen; Carter, Bernie; Carrol, E D

    2017-05-01

    Pediatric Early Warning Scores are advocated to assist health professionals to identify early signs of serious illness or deterioration in hospitalized children. Scores are derived from the weighting applied to recorded vital signs and clinical observations reflecting deviation from a predetermined "norm." Higher aggregate scores trigger an escalation in care aimed at preventing critical deterioration. Process errors made while recording these data, including plotting or calculation errors, have the potential to impede the reliability of the score. To test this hypothesis, we conducted a controlled study of documentation using five clinical vignettes. We measured the accuracy of vital sign recording, score calculation, and time taken to complete documentation using a handheld electronic physiological surveillance system, VitalPAC Pediatric, compared with traditional paper-based charts. We explored the user acceptability of both methods using a Web-based survey. Twenty-three staff participated in the controlled study. The electronic physiological surveillance system improved the accuracy of vital sign recording, 98.5% versus 85.6%, P < .02, Pediatric Early Warning Score calculation, 94.6% versus 55.7%, P < .02, and saved time, 68 versus 98 seconds, compared with paper-based documentation, P < .002. Twenty-nine staff completed the Web-based survey. They perceived that the electronic physiological surveillance system offered safety benefits by reducing human error while providing instant visibility of recorded data to the entire clinical team.

  18. Improving results for carotid artery stenting by validation of the anatomic scoring system for carotid artery stenting with patient-specific simulated rehearsal.

    PubMed

    Willaert, Willem I M; Cheshire, Nicholas J; Aggarwal, Rajesh; Van Herzeele, Isabelle; Stansby, Gerard; Macdonald, Sumaira; Vermassen, Frank E

    2012-12-01

    Carotid artery stenting (CAS) is a technically demanding procedure with a risk of periprocedural stroke. A scoring system based on anatomic criteria has been developed to facilitate patient selection for CAS. Advancements in simulation science also enable case evaluation through patient-specific virtual reality (VR) rehearsal on an endovascular simulator. This study aimed to validate the anatomic scoring system for CAS using the patient-specific VR technology. Three patients were selected and graded according to the CAS scoring system (maximum score, 9): one easy (score, <4.9), one intermediate (score, 5.0-5.9), and one difficult (score, >7.0). The three cases were performed on the simulator in random order by 20 novice interventionalists pretrained in CAS. Technical performances were assessed using simulator-based metrics and expert-based ratings. The interventionalists took significantly longer to perform the difficult CAS case (median, 31.6 vs 19.7 vs 14.6 minutes; P<.0001) compared with the intermediate and easy cases; similarly, more fluoroscopy time (20.7 vs 12.1 vs 8.2 minutes; P<.0001), contrast volume (56.5 vs 51.5 vs 50.0 mL; P=.0060), and roadmaps (10 vs 9 vs 9; P=.0040) were used. The quality of performance declined significantly as the cases became more challenging (score, 24 vs 22 vs 19; P<.0001). The anatomic scoring system for CAS can predict the difficulty of a CAS procedure as measured by patient-specific VR. This scoring system, with or without the additional use of patient-specific VR, can guide novice interventionalists in selecting appropriate patients for CAS. This may reduce the perioperative stroke risk and enhance patient safety. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  19. EUTOS CML prognostic scoring system predicts ELN-based 'event-free survival' better than Euro/Hasford and Sokal systems in CML patients receiving front-line imatinib mesylate.

    PubMed

    Uz, Burak; Buyukasik, Yahya; Atay, Hilmi; Kelkitli, Engin; Turgut, Mehmet; Bektas, Ozlen; Eliacik, Eylem; Isik, Ayşe; Aksu, Salih; Goker, Hakan; Sayinalp, Nilgun; Ozcebe, Osman I; Haznedaroglu, Ibrahim C

    2013-09-01

    The validity of the three currently used chronic myeloid leukemia (CML) scoring systems (Sokal CML prognostic scoring system, Euro/Hasford CML scoring system, and the EUTOS CML prognostic scoring system) were compared in the CML patients receiving frontline imatinib mesylate. One hundred and fourty-three chronic phase CML patients (71 males, 72 females) taking imatinib as frontline treatment were included in the study. The median age was 44 (16-82) years. Median total and on-imatinib follow-up durations were 29 (3.8-130) months and 25 (3-125) months, respectively. The complete hematological response (CHR) rate at 3 months was 95%. The best cumulative complete cytogenetic response (CCyR) rate at 24 months was 79.6%. Euro/Hasford scoring system was well-correlated with both Sokal and EUTOS scores (r = 0.6, P < 0.001 and r = 0.455, P < 0.001). However, there was only a weak correlation between Sokal and EUTOS scores (r = 0.2, P = 0.03). The 5-year median estimated event-free survival for low and high EUTOS risk patients were 62.6 (25.7-99.5) and 15.3 (7.4-23.2) months, respectively (P < 0.001). This performance was better than Sokal (P = 0.3) and Euro/Hasford (P = 0.04) scoring systems. Overall survival and CCyR rates were also better predicted by the EUTOS score. EUTOS CML prognostic scoring system, which is the only prognostic system developed during the imatinib era, predicts European LeukemiaNet (ELN)-based event-free survival better than Euro/Hasford and Sokal systems in CML patients receiving frontline imatinib mesylate. This observation might have important clinical implications.

  20. Comparison of L-system applications towards plant modelling, music rendering and score generation using visual language programming

    NASA Astrophysics Data System (ADS)

    Lim, Chen Kim; Tan, Kian Lam; Yusran, Hazwanni; Suppramaniam, Vicknesh

    2017-10-01

    Visual language or visual representation has been used in the past few years in order to express the knowledge in graphic. One of the important graphical elements is fractal and L-Systems is a mathematic-based grammatical model for modelling cell development and plant topology. From the plant model, L-Systems can be interpreted as music sound and score. In this paper, LSound which is a Visual Language Programming (VLP) framework has been developed to model plant to music sound and generate music score and vice versa. The objectives of this research has three folds: (i) To expand the grammar dictionary of L-Systems music based on visual programming, (ii) To design and produce a user-friendly and icon based visual language framework typically for L-Systems musical score generation which helps the basic learners in musical field and (iii) To generate music score from plant models and vice versa using L-Systems method. This research undergoes a four phases methodology where the plant is first modelled, then the music is interpreted, followed by the output of music sound through MIDI and finally score is generated. LSound is technically compared to other existing applications in the aspects of the capability of modelling the plant, rendering the music and generating the sound. It has been found that LSound is a flexible framework in which the plant can be easily altered through arrow-based programming and the music score can be altered through the music symbols and notes. This work encourages non-experts to understand L-Systems and music hand-in-hand.

  1. Scope Complexity Options Risks Excursions (SCORE) Factor Mathematical Description.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gearhart, Jared Lee; Samberson, Jonell Nicole; Shettigar, Subhasini

    The purpose of the Scope, Complexity, Options, Risks, Excursions (SCORE) model is to estimate the relative complexity of design variants of future warhead options, resulting in scores. SCORE factors extend this capability by providing estimates of complexity relative to a base system (i.e., all design options are normalized to one weapon system). First, a clearly defined set of scope elements for a warhead option is established. The complexity of each scope element is estimated by Subject Matter Experts (SMEs), including a level of uncertainty, relative to a specific reference system. When determining factors, complexity estimates for a scope element canmore » be directly tied to the base system or chained together via comparable scope elements in a string of reference systems that ends with the base system. The SCORE analysis process is a growing multi-organizational Nuclear Security Enterprise (NSE) effort, under the management of the NA-12 led Enterprise Modeling and Analysis Consortium (EMAC). Historically, it has provided the data elicitation, integration, and computation needed to support the out-year Life Extension Program (LEP) cost estimates included in the Stockpile Stewardship Management Plan (SSMP).« less

  2. Development of building energy asset rating using stock modelling in the USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Na; Goel, Supriya; Makhmalbaf, Atefe

    2016-01-29

    The US Building Energy Asset Score helps building stakeholders quickly gain insight into the efficiency of building systems (envelope, electrical and mechanical systems). A robust, easy-to-understand 10-point scoring system was developed to facilitate an unbiased comparison of similar building types across the country. The Asset Score does not rely on a database or specific building baselines to establish a rating. Rather, distributions of energy use intensity (EUI) for various building use types were constructed using Latin hypercube sampling and converted to a series of stepped linear scales to score buildings. A score is calculated based on the modelled source EUImore » after adjusting for climate. A web-based scoring tool, which incorporates an analytical engine and a simulation engine, was developed to standardize energy modelling and reduce implementation cost. This paper discusses the methodology used to perform several hundred thousand building simulation runs and develop the scoring scales.« less

  3. Validity of the Japanese Orthopaedic Association scoring system based on patient-reported improvement after posterior lumbar interbody fusion.

    PubMed

    Fujimori, Takahito; Okuda, Shinya; Iwasaki, Motoki; Yamasaki, Ryoji; Maeno, Takafumi; Yamashita, Tomoya; Matsumoto, Tomiya; Wada, Eiji; Oda, Takenori

    2016-06-01

    The Japanese Orthopaedic Association (JOA) scoring system is a physician-based outcome that has been used to evaluate treatment effectiveness after lumbar surgery. However, patient-centered evaluation becomes increasingly important. There is no study that has examined the relationship between the JOA scoring system and patients' self-reported improvement. The purpose of the present study was to validate the JOA scoring system for assessment of patient-reported improvement after lumbar surgery. This is a retrospective review of prospectively collected data. The patient sample included 273 mail-in responders of the 466 consecutive patients who underwent posterior lumbar interbody fusion for spondylolisthesis between 1996 and 2008 in a single hospital. The outcome measures were the JOA scoring system and patients' self-reported improvement. Two hundred seventy three patients were divided into five anchoring groups based on self-reported improvement from "Much better" to "Much worse." Outcomes (ie, recovery rate, amount of change from preoperative condition, and postoperative score) based on the JOA scoring system were compared among groups. Using the patient's self-reported improvement scale as an anchor, the association among each of the outcomes was examined. The cutoff point and the area under the curve (AUC) that differentiated "Improved" from "Neither improved nor worse" was calculated using receiver operating characteristic (ROC) curve analysis. The recovery rate and postoperative score were significantly different in 9 of 10 pairs of anchoring groups. The amount of change was significantly different in six pairs. Spearman correlation coefficient for the 5-point scale anchors of patients' self-reported improvement was 0.20 (p=.001) for the baseline score, 0.31 (p<.001) for the amount of change, 0.55 (p<.001) for the recovery rate, and 0.56 (p<.001) for the postoperative score. According to ROC analysis, the best cutoff points and AUCs were 13 points and 0.69, respectively, for the amount of change, 67% and 0.73, respectively, for recovery rate, and 23 points and 0.72, respectively, for postoperative score. The JOA scoring system is a valid method for assessment of patients' self-reported improvement. Patients' self-reported improvement is more likely to be associated with the final condition, such as postoperative score or recovery rate, rather than the change from the preoperative condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Initial assessment of facial nerve paralysis based on motion analysis using an optical flow method.

    PubMed

    Samsudin, Wan Syahirah W; Sundaraj, Kenneth; Ahmad, Amirozi; Salleh, Hasriah

    2016-01-01

    An initial assessment method that can classify as well as categorize the severity of paralysis into one of six levels according to the House-Brackmann (HB) system based on facial landmarks motion using an Optical Flow (OF) algorithm is proposed. The desired landmarks were obtained from the video recordings of 5 normal and 3 Bell's Palsy subjects and tracked using the Kanade-Lucas-Tomasi (KLT) method. A new scoring system based on the motion analysis using area measurement is proposed. This scoring system uses the individual scores from the facial exercises and grades the paralysis based on the HB system. The proposed method has obtained promising results and may play a pivotal role towards improved rehabilitation programs for patients.

  5. A prospective observational study comparing a physiological scoring system with time-based discharge criteria in pediatric ambulatory surgical patients.

    PubMed

    Armstrong, James; Forrest, Helen; Crawford, Mark W

    2015-10-01

    Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.

  6. Assessment of the 4Ts pretest clinical scoring system as a predictor of heparin-induced thrombocytopenia.

    PubMed

    Strutt, Jaclyn K; Mackey, Jennifer E; Johnson, Stephen M; Sylvia, Lynne M

    2011-02-01

    To evaluate the utility of the 4Ts clinical scoring system as a pretest probability method for the detection of heparin-induced thrombocytopenia (HIT). Prospective observational study. Medical and surgical inpatients at a tertiary care medical center. Eighty consecutive patients with suspicion of HIT who had a polyspecific enzyme-linked immunosorbent assay (ELISA) performed between December 1, 2008, and April 1, 2009, for detection of platelet factor 4 (PF4)-heparin antibodies. The predictive value of the 4Ts scoring system as determined by using a standard laboratory marker of HIT--the ELISA--and the interrater reliability of the scoring system were assessed. Sixty-seven (84%) of the 80 patients had low clinical probability of HIT based on the calculated 4Ts score. The ELISA result was negative for PF4-heparin antibodies in 74 patients (93%). Based on the results of the ELISA, the negative predictive value of the 4Ts score was 91%. Each 4Ts score was calculated by two independent investigators and adjudicated by a third investigator when necessary. The interrater reliability of the scoring system was fair (Cohen κ coefficient 0.362, 95% confidence interval [CI] 0.222-0.502; weighted κ coefficient 0.554 (95% CI 0.441-0.667). Determination of the timing of HIT was associated with the largest number of discrepancies (16) between evaluators, followed by other causes of thrombocytopenia (15), degree of decline in platelet count (14), and the presence of thrombosis or other sequelae (2). A low 4Ts score supports a low probability of HIT based on the results of the polyspecific ELISA. Overall, the interrater reliability of the scoring system was fair. Components of the 4Ts scoring system need to be further clarified or modified in order to improve interrater reliability and thereby increase the clinical utility of this pretest probability model.

  7. The accuracy of Internet search engines to predict diagnoses from symptoms can be assessed with a validated scoring system.

    PubMed

    Shenker, Bennett S

    2014-02-01

    To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (p<0.0001). Spearman's rho for test-retest reliability was 0.72 (p<0.0001). There was no difference in scores based on Internet search engine. We found a significant difference in scores based on the webpage's order on the Internet search engine webpage (p=0.007). Pairwise comparisons revealed higher scores in the first webpages vs. the fourth (corr p=0.009) and fifth (corr p=0.017). However, this significance was lost when creating composite scores. The five point scoring system to assess diagnostic accuracy of Internet search engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Accuracy and Efficiency of Recording Pediatric Early Warning Scores Using an Electronic Physiological Surveillance System Compared With Traditional Paper-Based Documentation

    PubMed Central

    Sefton, Gerri; Lane, Steven; Killen, Roger; Black, Stuart; Lyon, Max; Ampah, Pearl; Sproule, Cathryn; Loren-Gosling, Dominic; Richards, Caitlin; Spinty, Jean; Holloway, Colette; Davies, Coral; Wilson, April; Chean, Chung Shen; Carter, Bernie; Carrol, E.D.

    2017-01-01

    Pediatric Early Warning Scores are advocated to assist health professionals to identify early signs of serious illness or deterioration in hospitalized children. Scores are derived from the weighting applied to recorded vital signs and clinical observations reflecting deviation from a predetermined “norm.” Higher aggregate scores trigger an escalation in care aimed at preventing critical deterioration. Process errors made while recording these data, including plotting or calculation errors, have the potential to impede the reliability of the score. To test this hypothesis, we conducted a controlled study of documentation using five clinical vignettes. We measured the accuracy of vital sign recording, score calculation, and time taken to complete documentation using a handheld electronic physiological surveillance system, VitalPAC Pediatric, compared with traditional paper-based charts. We explored the user acceptability of both methods using a Web-based survey. Twenty-three staff participated in the controlled study. The electronic physiological surveillance system improved the accuracy of vital sign recording, 98.5% versus 85.6%, P < .02, Pediatric Early Warning Score calculation, 94.6% versus 55.7%, P < .02, and saved time, 68 versus 98 seconds, compared with paper-based documentation, P < .002. Twenty-nine staff completed the Web-based survey. They perceived that the electronic physiological surveillance system offered safety benefits by reducing human error while providing instant visibility of recorded data to the entire clinical team. PMID:27832032

  9. An Evaluation of the IntelliMetric[SM] Essay Scoring System

    ERIC Educational Resources Information Center

    Rudner, Lawrence M.; Garcia, Veronica; Welch, Catherine

    2006-01-01

    This report provides a two-part evaluation of the IntelliMetric[SM] automated essay scoring system based on its performance scoring essays from the Analytic Writing Assessment of the Graduate Management Admission Test[TM] (GMAT[TM]). The IntelliMetric system performance is first compared to that of individual human raters, a Bayesian system…

  10. New scoring system for intra-abdominal injury diagnosis after blunt trauma.

    PubMed

    Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali

    2014-01-01

    An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (score<8), moderate (8≤score<12) and high risk (score≥12). In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%). Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%). The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%). The present scoring system furnishes a high precision and reproducible diagnostic tool for BAT detection and has the potential to reduce unnecessary CT scan and cut unnecessary costs.

  11. A dysmorphology score system for assessing embryo abnormalities in rat whole embryo culture.

    PubMed

    Zhang, Cindy X; Danberry, Tracy; Jacobs, Mary Ann; Augustine-Rauch, Karen

    2010-12-01

    The rodent whole embryo culture (WEC) system is a well-established model for characterizing developmental toxicity of test compounds and conducting mechanistic studies. Laboratories have taken various approaches in describing type and severity of developmental findings of organogenesis-stage rodent embryos, but the Brown and Fabro morphological score system is commonly used as a quantitative approach. The associated score criteria is based upon developmental stage and growth parameters, where a series of embryonic structures are assessed and assigned respective scores relative to their gestational stage, with a Total Morphological Score (TMS) assigned to the embryo. This score system is beneficial because it assesses a series of stage-specific anatomical landmarks, facilitating harmonized evaluation across laboratories. Although the TMS provides a quantitative approach to assess growth and determine developmental delay, it is limited to its ability to identify and/or delineate subtle or structure-specific abnormalities. Because of this, the TMS may not be sufficiently sensitive for identifying compounds that induce structure or organ-selective effects. This study describes a distinct morphological score system called the "Dysmorphology Score System (DMS system)" that has been developed for assessing gestation day 11 (approximately 20-26 somite stage) rat embryos using numerical scores to differentiate normal from abnormal morphology and define the respective severity of dysmorphology of specific embryonic structures and organ systems. This method can also be used in scoring mouse embryos of the equivalent developmental stage. The DMS system enhances capabilities to rank-order compounds based upon teratogenic potency, conduct structure- relationships of chemicals, and develop statistical prediction models to support abbreviated developmental toxicity screens. © 2010 Wiley-Liss, Inc.

  12. Advanced clinical interpretation of the Delis-Kaplan Executive Function System: multivariate base rates of low scores.

    PubMed

    Karr, Justin E; Garcia-Barrera, Mauricio A; Holdnack, James A; Iverson, Grant L

    2018-01-01

    Multivariate base rates allow for the simultaneous statistical interpretation of multiple test scores, quantifying the normal frequency of low scores on a test battery. This study provides multivariate base rates for the Delis-Kaplan Executive Function System (D-KEFS). The D-KEFS consists of 9 tests with 16 Total Achievement scores (i.e. primary indicators of executive function ability). Stratified by education and intelligence, multivariate base rates were derived for the full D-KEFS and an abbreviated four-test battery (i.e. Trail Making, Color-Word Interference, Verbal Fluency, and Tower Test) using the adult portion of the normative sample (ages 16-89). Multivariate base rates are provided for the full and four-test D-KEFS batteries, calculated using five low score cutoffs (i.e. ≤25th, 16th, 9th, 5th, and 2nd percentiles). Low scores occurred commonly among the D-KEFS normative sample, with 82.6 and 71.8% of participants obtaining at least one score ≤16th percentile for the full and four-test batteries, respectively. Intelligence and education were inversely related to low score frequency. The base rates provided herein allow clinicians to interpret multiple D-KEFS scores simultaneously for the full D-KEFS and an abbreviated battery of commonly administered tests. The use of these base rates will support clinicians when differentiating between normal variations in cognitive performance and true executive function deficits.

  13. 64 slice MDCT generally underestimates coronary calcium scores as compared to EBT: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greuter, M. J. W.; Dijkstra, H.; Groen, J. M.

    The objective of our study was the determination of the influence of the sequential and spiral acquisition modes on the concordance and deviation of the calcium score on 64-slice multi-detector computed tomography (MDCT) scanners in comparison to electron beam tomography (EBT) as the gold standard. Our methods and materials were an anthropomorphic cardio CT phantom with different calcium inserts scanned in sequential and spiral acquisition modes on three identical 64-slice MDCT scanners of manufacturer A and on three identical 64-slice MDCT scanners of manufacturer B and on an EBT system. Every scan was repeated 30 times with and 15 timesmore » without a small random variation in the phantom position for both sequential and spiral modes. Significant differences were observed between EBT and 64-slice MDCT data for all inserts, both acquisition modes, and both manufacturers of MDCT systems. High regression coefficients (0.90-0.98) were found between the EBT and 64-slice MDCT data for both scoring methods and both systems with high correlation coefficients (R{sup 2}>0.94). System A showed more significant differences between spiral and sequential mode than system B. Almost no differences were observed in scanners of the same manufacturer for the Agatston score and no differences for the Volume score. The deviations of the Agatston and Volume scores showed regression dependencies approximately equal to the square root of the absolute score. The Agatston and Volume scores obtained with 64-slice MDCT imaging are highly correlated with EBT-obtained scores but are significantly underestimated (-10% to -2%) for both sequential and spiral acquisition modes. System B is more independent of acquisition mode to calcium score than system A. The Volume score shows no intramanufacturer dependency and its use is advocated versus the Agatston score. Using the same cut points for MDCT-based calcium scores as for EBT-based calcium scores can result in classifying individuals into a too low risk category. System information and scanprotocol is therefore needed for every calcium score procedure to ensure a correct clinical interpretation of the obtained calcium score results.« less

  14. A scoring system based on artificial neural network for predicting 10-year survival in stage II A colon cancer patients after radical surgery.

    PubMed

    Peng, Jian-Hong; Fang, Yu-Jing; Li, Cai-Xia; Ou, Qing-Jian; Jiang, Wu; Lu, Shi-Xun; Lu, Zhen-Hai; Li, Pei-Xing; Yun, Jing-Ping; Zhang, Rong-Xin; Pan, Zhi-Zhong; Wan, De Sen

    2016-04-19

    Nearly 20% patients with stage II A colon cancer will develop recurrent disease post-operatively. The present study aims to develop a scoring system based on Artificial Neural Network (ANN) model for predicting 10-year survival outcome. The clinical and molecular data of 117 stage II A colon cancer patients from Sun Yat-sen University Cancer Center were used for training set and test set; poor pathological grading (score 49), reduced expression of TGFBR2 (score 33), over-expression of TGF-β (score 45), MAPK (score 32), pin1 (score 100), β-catenin in tumor tissue (score 50) and reduced expression of TGF-β in normal mucosa (score 22) were selected as the prognostic risk predictors. According to the developed scoring system, the patients were divided into 3 subgroups, which were supposed with higher, moderate and lower risk levels. As a result, for the 3 subgroups, the 10-year overall survival (OS) rates were 16.7%, 62.9% and 100% (P < 0.001); and the 10-year disease free survival (DFS) rates were 16.7%, 61.8% and 98.8% (P < 0.001) respectively. It showed that this scoring system for stage II A colon cancer could help to predict long-term survival and screen out high-risk individuals for more vigorous treatment.

  15. Immunization-based scores as independent prognostic predictors in soft tissue sarcoma patients

    PubMed Central

    Jiang, Shan-Shan; Jiang, Long; Weng, De-Sheng; Li, Yuan-fang; Pan, Qiu-Zhong; Zhao, Jing-Jing; Tang, Yan; Zhou, Zhi-Wei; Xia, Jian-Chuan

    2017-01-01

    Background: The purpose of this study was to examine and compare the prognostic value of different immunization-based scoring systems in patients with soft tissue sarcoma (STS). Methods: We conducted a retrospective study evaluating a cohort of 165 patients diagnosed with STS between July 2007 and July 2014. The relative Glasgow prognostic score (GPS) of these patients was calculated using 3 different systems: the traditional GPS system (tGPS), the modified GPS system 1 (m1GPS), and the modified GPS system 2 (m2GPS). Then, we evaluated the relationships between each GPS system and clinicopathological characteristics. The mean follow-up for survivors in the cohort was 73.7 months as of March 2015. Results: The most favorable overall survival (OS) rate was associated with the score 0 groups, and the poorest progression-free survival (PFS) rate was associated with the score 2 groups, regardless of which system was used to calculate the score. Specifically, the m1GPS provided the greatest accuracy in predicting OS and PFS. Moreover, the same effect was observed in a separate analysis restricted to patients with metastases. Remarkably, in patients with a score of 2 as measured by all 3 systems, local treatment resulted in a poorer prognosis compared to patients with a score of 2 who did not receive local treatment. Conclusion: The GPS is a valuable prognostic marker and has the capability to predict the appropriate treatment strategy for STS patients with metastases. The modified GPS systems demonstrated superior prognostic and predictive value compared with the traditional GPS system. PMID:28367240

  16. Rating Pregnancy Wheel Applications Using the APPLICATIONS Scoring System.

    PubMed

    Chyjek, Kathy; Farag, Sara; Chen, Katherine T

    2015-06-01

    To identify the top-rated pregnancy wheel applications (apps) using a newly developed APPLICATIONS scoring system. A list of pregnancy wheel apps was identified. Consumer-based and inaccurate apps were excluded. The APPLICATIONS scoring system was developed to rate the remaining apps. Application comprehensiveness was evaluated. Objective rating components included price, paid subscription, literature used, in-app purchases, connectivity to the Internet, advertisements, text search field, interdevice compatibility, and other components such as images or figures, videos, and special features. Subjective rating components were ease of navigation and subjective presentation. A complete list of 55 pregnancy wheel apps was created from three sources. Thirty-nine (71%) were consumer-based, inaccurate, or both, leaving 16 (29%) for analysis using the APPLICATIONS scoring system. More than two thirds of pregnancy wheel apps were excluded from our study secondary to being consumer-based, inaccurate, or both. This highlights the importance of identifying systematically, reviewing critically, and rating the thousands of available apps to health care providers to ensure accuracy and applicability. We propose that our APPLICATIONS scoring system be used to rate apps in all specialties with the goal of improving health care provider performance and thereby patient outcomes. III.

  17. Testing the radiosurgery-based arteriovenous malformation score and the modified Spetzler-Martin grading system to predict radiosurgical outcome.

    PubMed

    Andrade-Souza, Yuri M; Zadeh, Gelareh; Ramani, Meera; Scora, Daryl; Tsao, May N; Schwartz, Michael L

    2005-10-01

    The aim of this study was to validate the radiosurgery-based arteriovenous malformation (AVM) score and the modified Spetzler-Martin grading system to predict radiosurgical outcome. One hundred thirty-six patients with brain AVMs were randomly selected. These patients had undergone a linear accelerator radiosurgical procedure at a single center between 1989 and 2000. Patients were divided into four groups according to an AVM score, which was calculated from the lesion volume, lesion location, and patient age (Group 1, AVM score <1; Group 2, AVM score 1-1.49; Group 3, AVM score 1.5-2; and Group 4, AVM score >2). Patients with a Spetzler-Martin Grade III AVM were divided into Grades IIIA (lesion >3 cm) and IIIB (lesion <3 cm). Sixty-two female (45.6%) and 74 male (54.4%) patients with a median age of 37.5 years (mean 37.5 years, range 5-77 years) were followed up for a median of 40 months. The median tumor margin dose was 15 Gy (mean 17.23 Gy, range 15-25 Gy). The proportions of excellent outcomes according to the AVM score were as follows: 91.7% for Group 1, 74.1% for Group 2, 60% for Group 3, and 33.3% for Group 4 (chi-square test, degrees of freedom (df) = 3, p < 0.001). Based on the modified Spetzler-Martin system, Grade I lesions had 88.9% excellent results; Grade II, 69.6%; Grade IIIB, 61.5%; and Grades IIIA and IV, 44.8% (chi-square test, df = 3, p = 0.047). The radiosurgery-based AVM score can be used accurately to predict excellent results following a single radiosurgical treatment for AVM. The modified Spetzler-Martin system can also predict radiosurgical results for AVMs, thus making it possible to use this system while deciding between surgery and radiosurgery.

  18. Web-based education in systems-based practice: a randomized trial.

    PubMed

    Kerfoot, B Price; Conlin, Paul R; Travison, Thomas; McMahon, Graham T

    2007-02-26

    All accredited US residency programs are expected to offer curricula and evaluate their residents in 6 general competencies. Medical schools are now adopting similar competency frameworks. We investigated whether a Web-based program could effectively teach and assess elements of systems-based practice. We enrolled 276 medical students and 417 residents in the fields of surgery, medicine, obstetrics-gynecology, and emergency medicine in a 9-week randomized, controlled, crossover educational trial. Participants were asked to sequentially complete validated Web-based modules on patient safety and the US health care system. The primary outcome measure was performance on a 26-item validated online test administered before, between, and after the participants completed the modules. Six hundred forty (92.4%) of the 693 enrollees participated in the study; 512 (80.0%) of the participants completed all 3 tests. Participants' test scores improved significantly after completion of the first module (P<.001). Overall learning from the 9-week Web-based program, as measured by the increase in scores (posttest scores minus pretest scores), was 16 percentage points (95% confidence interval, 14-17 percentage points; P<.001) in public safety topics and 22 percentage points (95% confidence interval, 20-23 percentage points; P<.001) in US health care system topics. A Web-based educational program on systems-based practice competencies generated significant and durable learning across a broad range of medical students and residents.

  19. Gene network inherent in genomic big data improves the accuracy of prognostic prediction for cancer patients.

    PubMed

    Kim, Yun Hak; Jeong, Dae Cheon; Pak, Kyoungjune; Goh, Tae Sik; Lee, Chi-Seung; Han, Myoung-Eun; Kim, Ji-Young; Liangwen, Liu; Kim, Chi Dae; Jang, Jeon Yeob; Cha, Wonjae; Oh, Sae-Ock

    2017-09-29

    Accurate prediction of prognosis is critical for therapeutic decisions regarding cancer patients. Many previously developed prognostic scoring systems have limitations in reflecting recent progress in the field of cancer biology such as microarray, next-generation sequencing, and signaling pathways. To develop a new prognostic scoring system for cancer patients, we used mRNA expression and clinical data in various independent breast cancer cohorts (n=1214) from the Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and Gene Expression Omnibus (GEO). A new prognostic score that reflects gene network inherent in genomic big data was calculated using Network-Regularized high-dimensional Cox-regression (Net-score). We compared its discriminatory power with those of two previously used statistical methods: stepwise variable selection via univariate Cox regression (Uni-score) and Cox regression via Elastic net (Enet-score). The Net scoring system showed better discriminatory power in prediction of disease-specific survival (DSS) than other statistical methods (p=0 in METABRIC training cohort, p=0.000331, 4.58e-06 in two METABRIC validation cohorts) when accuracy was examined by log-rank test. Notably, comparison of C-index and AUC values in receiver operating characteristic analysis at 5 years showed fewer differences between training and validation cohorts with the Net scoring system than other statistical methods, suggesting minimal overfitting. The Net-based scoring system also successfully predicted prognosis in various independent GEO cohorts with high discriminatory power. In conclusion, the Net-based scoring system showed better discriminative power than previous statistical methods in prognostic prediction for breast cancer patients. This new system will mark a new era in prognosis prediction for cancer patients.

  20. Gene network inherent in genomic big data improves the accuracy of prognostic prediction for cancer patients

    PubMed Central

    Kim, Yun Hak; Jeong, Dae Cheon; Pak, Kyoungjune; Goh, Tae Sik; Lee, Chi-Seung; Han, Myoung-Eun; Kim, Ji-Young; Liangwen, Liu; Kim, Chi Dae; Jang, Jeon Yeob; Cha, Wonjae; Oh, Sae-Ock

    2017-01-01

    Accurate prediction of prognosis is critical for therapeutic decisions regarding cancer patients. Many previously developed prognostic scoring systems have limitations in reflecting recent progress in the field of cancer biology such as microarray, next-generation sequencing, and signaling pathways. To develop a new prognostic scoring system for cancer patients, we used mRNA expression and clinical data in various independent breast cancer cohorts (n=1214) from the Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and Gene Expression Omnibus (GEO). A new prognostic score that reflects gene network inherent in genomic big data was calculated using Network-Regularized high-dimensional Cox-regression (Net-score). We compared its discriminatory power with those of two previously used statistical methods: stepwise variable selection via univariate Cox regression (Uni-score) and Cox regression via Elastic net (Enet-score). The Net scoring system showed better discriminatory power in prediction of disease-specific survival (DSS) than other statistical methods (p=0 in METABRIC training cohort, p=0.000331, 4.58e-06 in two METABRIC validation cohorts) when accuracy was examined by log-rank test. Notably, comparison of C-index and AUC values in receiver operating characteristic analysis at 5 years showed fewer differences between training and validation cohorts with the Net scoring system than other statistical methods, suggesting minimal overfitting. The Net-based scoring system also successfully predicted prognosis in various independent GEO cohorts with high discriminatory power. In conclusion, the Net-based scoring system showed better discriminative power than previous statistical methods in prognostic prediction for breast cancer patients. This new system will mark a new era in prognosis prediction for cancer patients. PMID:29100405

  1. The Motivational Value Systems Questionnaire (MVSQ): Psychometric Analysis Using a Forced Choice Thurstonian IRT Model

    PubMed Central

    Merk, Josef; Schlotz, Wolff; Falter, Thomas

    2017-01-01

    This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts. PMID:28979228

  2. The Motivational Value Systems Questionnaire (MVSQ): Psychometric Analysis Using a Forced Choice Thurstonian IRT Model.

    PubMed

    Merk, Josef; Schlotz, Wolff; Falter, Thomas

    2017-01-01

    This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts.

  3. AVQS: attack route-based vulnerability quantification scheme for smart grid.

    PubMed

    Ko, Jongbin; Lim, Hyunwoo; Lee, Seokjun; Shon, Taeshik

    2014-01-01

    A smart grid is a large, consolidated electrical grid system that includes heterogeneous networks and systems. Based on the data, a smart grid system has a potential security threat in its network connectivity. To solve this problem, we develop and apply a novel scheme to measure the vulnerability in a smart grid domain. Vulnerability quantification can be the first step in security analysis because it can help prioritize the security problems. However, existing vulnerability quantification schemes are not suitable for smart grid because they do not consider network vulnerabilities. We propose a novel attack route-based vulnerability quantification scheme using a network vulnerability score and an end-to-end security score, depending on the specific smart grid network environment to calculate the vulnerability score for a particular attack route. To evaluate the proposed approach, we derive several attack scenarios from the advanced metering infrastructure domain. The experimental results of the proposed approach and the existing common vulnerability scoring system clearly show that we need to consider network connectivity for more optimized vulnerability quantification.

  4. A relative-value-based system for calculating faculty productivity in teaching, research, administration, and patient care.

    PubMed

    Hilton, C; Fisher, W; Lopez, A; Sanders, C

    1997-09-01

    To design and test a simple, easily modifiable system for calculating faculty productivity in teaching, research, administration, and patient care in which all areas of endeavor would be recognized and high productivity in one area would produce results similar to high productivity in another at the Louisiana State University School of Medicine in New Orleans. A relative-value and time-based system was designed in 1996 so that similar efforts in the four areas would produce similar scores, and a profile reflecting the authors' estimates of high productivity ("super faculty") was developed for each area. The activity profiles of 17 faculty members were used to test the system. "Super-faculty" scores in all areas were similar. The faculty members' mean scores were higher for teaching and research than for administration and patient care, and all four mean scores were substantially lower than the respective totals for the "super faculty". In each category the scores of those faculty members who scored above the mean in that category were used to calculate new mean scores. The mean scores for these faculty members were similar to those for the "super faculty" in teaching and research but were substantially lower for administration and patient care. When the mean total score of the eight faculty members predicted to have total scores below the group mean was compared with the mean total score of the nine faculty members predicted to have total scores above the group mean, the difference was significant (p < .0001). For the former, every score in each category was below the mean, with the exception of one faculty member's score in one category. Of the latter, eight had higher scores in teaching and four had higher scores in teaching and research combined. This system provides a quantitative method for the equal recognition of faculty productivity in a number of areas, and it may be useful as a starting point for other academic units exploring similar issues.

  5. 99mTc MDP SPECT-CT-Based Modified Mirels Classification for Evaluation of Risk of Fracture in Skeletal Metastasis: A Pilot Study.

    PubMed

    Riaz, Saima; Bashir, Humayun; Niazi, Imran Khalid; Butt, Sumera; Qamar, Faisal

    2018-06-01

    Mirels' scoring system quantifies the risk of sustaining a pathologic fracture in osseous metastases of weight bearing long bones. Conventional Mirels' scoring is based on radiographs. Our pilot study proposes Tc MDP bone SPECT-CT based modified Mirels' scoring system and its comparison with conventional Mirels' scoring. Cortical lysis was noted in 8(24%) by SPECT-CT versus 2 (6.3%) on X-rays. Additional SPECT-CT parameters were; circumferential involvement [1/4 (31%), 1/2 (3%), 3/4 (37.5%), 4/4 (28%)] and extra-osseous soft tissue [3%]. Our pilot study suggests the potential role of SPECT-CT in predicting risk of fracture in osseous metastases.

  6. Interactive web-based learning modules prior to general medicine advanced pharmacy practice experiences.

    PubMed

    Isaacs, Alex N; Walton, Alison M; Nisly, Sarah A

    2015-04-25

    To implement and evaluate interactive web-based learning modules prior to advanced pharmacy practice experiences (APPEs) on inpatient general medicine. Three clinical web-based learning modules were developed for use prior to APPEs in 4 health care systems. The aim of the interactive modules was to strengthen baseline clinical knowledge before the APPE to enable the application of learned material through the delivery of patient care. For the primary endpoint, postassessment scores increased overall and for each individual module compared to preassessment scores. Postassessment scores were similar among the health care systems. The survey demonstrated positive student perceptions of this learning experience. Prior to inpatient general medicine APPEs, web-based learning enabled the standardization and assessment of baseline student knowledge across 4 health care systems.

  7. Training and Assessing Interprofessional Virtual Teams Using a Web-Based Case System.

    PubMed

    Dow, Alan W; Boling, Peter A; Lockeman, Kelly S; Mazmanian, Paul E; Feldman, Moshe; DiazGranados, Deborah; Browning, Joel; Coe, Antoinette; Selby-Penczak, Rachel; Hobgood, Sarah; Abbey, Linda; Parsons, Pamela; Delafuente, Jeffrey; Taylor, Suzanne F

    2016-01-01

    Today, clinical care is often provided by interprofessional virtual teams-groups of practitioners who work asynchronously and use technology to communicate. Members of such teams must be competent in interprofessional practice and the use of information technology, two targets for health professions education reform. The authors created a Web-based case system to teach and assess these competencies in health professions students. They created a four-module, six-week geriatric learning experience using a Web-based case system. Health professions students were divided into interprofessional virtual teams. Team members received profession-specific information, entered a summary of this information into the case system's electronic health record, answered knowledge questions about the case individually, then collaborated asynchronously to answer the same questions as a team. Individual and team knowledge scores and case activity measures--number of logins, message board posts/replies, views of message board posts--were tracked. During academic year 2012-2013, 80 teams composed of 522 students from medicine, nursing, pharmacy, and social work participated. Knowledge scores varied by profession and within professions. Team scores were higher than individual scores (P < .001). Students and teams with higher knowledge scores had higher case activity measures. Team score was most highly correlated with number of message board posts/replies and was not correlated with number of views of message board posts. This Web-based case system provided a novel approach to teach and assess the competencies needed for virtual teams. This approach may be a valuable new tool for measuring competency in interprofessional practice.

  8. Qualitative and quantitative outcomes of audience response systems as an educational tool in a plastic surgery residency program.

    PubMed

    Arneja, Jugpal S; Narasimhan, Kailash; Bouwman, David; Bridge, Patrick D

    2009-12-01

    In-training evaluations in graduate medical education have typically been challenging. Although the majority of standardized examination delivery methods have become computer-based, in-training examinations generally remain pencil-paper-based, if they are performed at all. Audience response systems present a novel way to stimulate and evaluate the resident-learner. The purpose of this study was to assess the outcomes of audience response systems testing as compared with traditional testing in a plastic surgery residency program. A prospective 1-year pilot study of 10 plastic surgery residents was performed using audience response systems-delivered testing for the first half of the academic year and traditional pencil-paper testing for the second half. Examination content was based on monthly "Core Quest" curriculum conferences. Quantitative outcome measures included comparison of pretest and posttest and cumulative test scores of both formats. Qualitative outcomes from the individual participants were obtained by questionnaire. When using the audience response systems format, pretest and posttest mean scores were 67.5 and 82.5 percent, respectively; using traditional pencil-paper format, scores were 56.5 percent and 79.5 percent. A comparison of the cumulative mean audience response systems score (85.0 percent) and traditional pencil-paper score (75.0 percent) revealed statistically significantly higher scores with audience response systems (p = 0.01). Qualitative outcomes revealed increased conference enthusiasm, greater enjoyment of testing, and no user difficulties with the audience response systems technology. The audience response systems modality of in-training evaluation captures participant interest and reinforces material more effectively than traditional pencil-paper testing does. The advantages include a more interactive learning environment, stimulation of class participation, immediate feedback to residents, and immediate tabulation of results for the educator. Disadvantages include start-up costs and lead-time preparation.

  9. Scoring and staging systems using cox linear regression modeling and recursive partitioning.

    PubMed

    Lee, J W; Um, S H; Lee, J B; Mun, J; Cho, H

    2006-01-01

    Scoring and staging systems are used to determine the order and class of data according to predictors. Systems used for medical data, such as the Child-Turcotte-Pugh scoring and staging systems for ordering and classifying patients with liver disease, are often derived strictly from physicians' experience and intuition. We construct objective and data-based scoring/staging systems using statistical methods. We consider Cox linear regression modeling and recursive partitioning techniques for censored survival data. In particular, to obtain a target number of stages we propose cross-validation and amalgamation algorithms. We also propose an algorithm for constructing scoring and staging systems by integrating local Cox linear regression models into recursive partitioning, so that we can retain the merits of both methods such as superior predictive accuracy, ease of use, and detection of interactions between predictors. The staging system construction algorithms are compared by cross-validation evaluation of real data. The data-based cross-validation comparison shows that Cox linear regression modeling is somewhat better than recursive partitioning when there are only continuous predictors, while recursive partitioning is better when there are significant categorical predictors. The proposed local Cox linear recursive partitioning has better predictive accuracy than Cox linear modeling and simple recursive partitioning. This study indicates that integrating local linear modeling into recursive partitioning can significantly improve prediction accuracy in constructing scoring and staging systems.

  10. The Effect of Training Data Set Composition on the Performance of a Neural Image Caption Generator

    DTIC Science & Technology

    2017-09-01

    objects was compared using the Metric for Evaluation of Translation with Explicit Ordering (METEOR) and Consensus-Based Image Description Evaluation...using automated scoring systems. Many such systems exist, including Bilingual Evaluation Understudy (BLEU), Consensus-Based Image Description Evaluation...shown to be essential to automated scoring, which correlates highly with human precision.5 CIDEr uses a system of consensus among the captions and

  11. Prediction of significant conduction disease through noninvasive assessment of cardiac calcification.

    PubMed

    Mainigi, Sumeet K; Chebrolu, Lakshmi Hima Bindu; Romero-Corral, Abel; Mehta, Vinay; Machado, Rodolfo Rozindo; Konecny, Tomas; Pressman, Gregg S

    2012-10-01

    Cardiac calcification is associated with coronary artery disease, arrhythmias, conduction disease, and adverse cardiac events. Recently, we have described an echocardiographic-based global cardiac calcification scoring system. The objective of this study was to evaluate the severity of cardiac calcification in patients with permanent pacemakers as based on this scoring system. Patients with a pacemaker implanted within the 2-year study period with a previous echocardiogram were identified and underwent blinded global cardiac calcium scoring. These patients were compared to matched control patients without a pacemaker who also underwent calcium scoring. The study group consisted of 49 patients with pacemaker implantation who were compared to 100 matched control patients. The mean calcium score in the pacemaker group was 3.3 ± 2.9 versus 1.8 ± 2.0 (P = 0.006) in the control group. Univariate and multivariate analysis revealed glomerular filtration rate and calcium scoring to be significant predictors of the presence of a pacemaker. Echocardiographic-based calcium scoring correlates with the presence of severe conduction disease requiring a pacemaker. © 2012, Wiley Periodicals, Inc.

  12. Observation chart design features affect the detection of patient deterioration: a systematic experimental evaluation.

    PubMed

    Christofidis, Melany J; Hill, Andrew; Horswill, Mark S; Watson, Marcus O

    2016-01-01

    To systematically evaluate the impact of several design features on chart-users' detection of patient deterioration on observation charts with early-warning scoring-systems. Research has shown that observation chart design affects the speed and accuracy with which abnormal observations are detected. However, little is known about the contribution of individual design features to these effects. A 2 × 2 × 2 × 2 mixed factorial design, with data-recording format (drawn dots vs. written numbers), scoring-system integration (integrated colour-based system vs. non-integrated tabular system) and scoring-row placement (grouped vs. separate) varied within-participants and scores (present vs. absent) varied between-participants by random assignment. 205 novice chart-users, tested between March 2011-March 2014, completed 64 trials where they saw real patient data presented on an observation chart. Each participant saw eight cases (four containing abnormal observations) on each of eight designs (which represented a factorial combination of the within-participants variables). On each trial, they assessed whether any of the observations were physiologically abnormal, or whether all observations were normal. Response times and error rates were recorded for each design. Participants responded faster (scores present and absent) and made fewer errors (scores absent) using drawn-dot (vs. written-number) observations and an integrated colour-based (vs. non-integrated tabular) scoring-system. Participants responded faster using grouped (vs. separate) scoring-rows when scores were absent, but separate scoring-rows when scores were present. Our findings suggest that several individual design features can affect novice chart-users' ability to detect patient deterioration. More broadly, the study further demonstrates the need to evaluate chart designs empirically. © 2015 John Wiley & Sons Ltd.

  13. Evaluation of an inflammation-based prognostic score in patients with metastatic renal cancer.

    PubMed

    Ramsey, Sara; Lamb, Gavin W A; Aitchison, Michael; Graham, John; McMillan, Donald C

    2007-01-15

    Recently, it was shown that an inflammation-based prognostic score, the Glasgow Prognostic Score (GPS), provides additional prognostic information in patients with advanced cancer. The objective of the current study was to examine the value of the GPS compared with established scoring systems in predicting cancer-specific survival in patients with metastatic renal cancer. One hundred nineteen patients who underwent immunotherapy for metastatic renal cancer were recruited. The Memorial Sloan-Kettering Cancer Center (MSKCC) score and the Metastatic Renal Carcinoma Comprehensive Prognostic System (MRCCPS) score were calculated as described previously. Patients who had both an elevated C-reactive protein level (>10 mg/L) and hypoalbuminemia (<35 g/L) were allocated a GPS of 2. Patients who had only 1 of those 2 biochemical abnormalities were allocated a GPS of 1. Patients who had neither abnormality were allocated a GPS of 0. On multivariate analysis of significant individual factors, only calcium (hazard ratio [HR], 3.21; 95% confidence interval [95% CI], 1.51-6.83; P = .002), white cell count (HR, 1.66; 95% CI, 1.17-2.35; P = .004), albumin (HR, 2.63; 95% CI, 1.38-5.03; P = .003), and C-reactive protein (HR, 2.85; 95% CI; 1.49-5.45; P = .002) were associated independently with cancer-specific survival. On multivariate analysis of the different scoring systems, the MSKCC (HR, 1.88; 95% CI, 1.22-2.88; P = .004), the MRCCPS (HR, 1.42; 95% CI, 0.97-2.09; P = .071), and the GPS (HR, 2.35; 95% CI, 1.51-3.67; P < .001) were associated independently with cancer-specific survival. An inflammation-based prognostic score (GPS) predicted survival independent of established scoring systems in patients with metastatic renal cancer.

  14. Information contained in miscarriage-related websites and the predictive value of website scoring systems.

    PubMed

    Hardwick, J Christopher R; MacKenzie, Fiona M

    2003-01-10

    To identify websites providing information about early pregnancy loss and compare this information with published guidelines from the Royal College of Obstetricians and Gynaecologists (RCOG). The value of 'Silberg' and 'Health on the net (HON)' website scoring systems in predicting the information provided via websites identified was assessed. A cross-sectional survey. Nineteen websites identified via two search engines (http://www.lycos.co.uk and http://www.msn.co.uk). Websites were searched for specific information in a structured manner and then scored by two independent observers against the website scoring systems and against a scoring system derived from guidelines published by the RCOG. Website scores against the scoring systems and against RCOG guidelines. Information concerning miscarriage contained within these websites was poor and scored accordingly against the RCOG guidelines (median score, 4.5/8). The website scoring systems did not predict the RCOG scores for a website (HON score R(S)=0.193 (95% confidence interval from -0.286 to 0.595), Silberg score, R(S)=0.035 (95% confidence interval from -0.426 to 0.482)). Few relevant websites were identified despite searching a large number via two search engines. The websites found did not answer our specific questions and consequently scored poorly against the RCOG guidelines. RCOG scores did not correlate with either scoring system. Web-based information for women attending with early pregnancy complications needs to be easily accessed and comprehensive. Written information given to women when seen with early pregnancy complications should include details of available comprehensive websites. Professional organisations, colleges or Government agencies should provide this type of information.

  15. The discriminatory capability of existing scores to predict advanced colorectal neoplasia: a prospective colonoscopy study of 5,899 screening participants.

    PubMed

    Wong, Martin C S; Ching, Jessica Y L; Ng, Simpson; Lam, Thomas Y T; Luk, Arthur K C; Wong, Sunny H; Ng, Siew C; Ng, Simon S M; Wu, Justin C Y; Chan, Francis K L; Sung, Joseph J Y

    2016-02-03

    We evaluated the performance of seven existing risk scoring systems in predicting advanced colorectal neoplasia in an asymptomatic Chinese cohort. We prospectively recruited 5,899 Chinese subjects aged 50-70 years in a colonoscopy screening programme(2008-2014). Scoring systems under evaluation included two scoring tools from the US; one each from Spain, Germany, and Poland; the Korean Colorectal Screening(KCS) scores; and the modified Asia Pacific Colorectal Screening(APCS) scores. The c-statistics, sensitivity, specificity, positive predictive values(PPVs), and negative predictive values(NPVs) of these systems were evaluated. The resources required were estimated based on the Number Needed to Screen(NNS) and the Number Needed to Refer for colonoscopy(NNR). Advanced neoplasia was detected in 364 (6.2%) subjects. The German system referred the least proportion of subjects (11.2%) for colonoscopy, whilst the KCS scoring system referred the highest (27.4%). The c-statistics of all systems ranged from 0.56-0.65, with sensitivities ranging from 0.04-0.44 and specificities from 0.74-0.99. The modified APCS scoring system had the highest c-statistics (0.65, 95% C.I. 0.58-0.72). The NNS (12-19) and NNR (5-10) were similar among the scoring systems. The existing scoring systems have variable capability to predict advanced neoplasia among asymptomatic Chinese subjects, and further external validation should be performed.

  16. Computer-enhanced laparoscopic training system (CELTS): bridging the gap.

    PubMed

    Stylopoulos, N; Cotin, S; Maithel, S K; Ottensmeye, M; Jackson, P G; Bardsley, R S; Neumann, P F; Rattner, D W; Dawson, S L

    2004-05-01

    There is a large and growing gap between the need for better surgical training methodologies and the systems currently available for such training. In an effort to bridge this gap and overcome the disadvantages of the training simulators now in use, we developed the Computer-Enhanced Laparoscopic Training System (CELTS). CELTS is a computer-based system capable of tracking the motion of laparoscopic instruments and providing feedback about performance in real time. CELTS consists of a mechanical interface, a customizable set of tasks, and an Internet-based software interface. The special cognitive and psychomotor skills a laparoscopic surgeon should master were explicitly defined and transformed into quantitative metrics based on kinematics analysis theory. A single global standardized and task-independent scoring system utilizing a z-score statistic was developed. Validation exercises were performed. The scoring system clearly revealed a gap between experts and trainees, irrespective of the task performed; none of the trainees obtained a score above the threshold that distinguishes the two groups. Moreover, CELTS provided educational feedback by identifying the key factors that contributed to the overall score. Among the defined metrics, depth perception, smoothness of motion, instrument orientation, and the outcome of the task are major indicators of performance and key parameters that distinguish experts from trainees. Time and path length alone, which are the most commonly used metrics in currently available systems, are not considered good indicators of performance. CELTS is a novel and standardized skills trainer that combines the advantages of computer simulation with the features of the traditional and popular training boxes. CELTS can easily be used with a wide array of tasks and ensures comparability across different training conditions. This report further shows that a set of appropriate and clinically relevant performance metrics can be defined and a standardized scoring system can be designed.

  17. Self-Monitoring Assessments for Educational Accountability Systems

    ERIC Educational Resources Information Center

    Koretz, Daniel; Beguin, Anton

    2010-01-01

    Test-based accountability is now the cornerstone of U.S. education policy, and it is becoming more important in many other nations as well. Educators sometimes respond to test-based accountability in ways that produce score inflation. In the past, score inflation has usually been evaluated by comparing trends in scores on a high-stakes test to…

  18. Simple Scoring System to Predict In-Hospital Mortality After Surgery for Infective Endocarditis.

    PubMed

    Gatti, Giuseppe; Perrotti, Andrea; Obadia, Jean-François; Duval, Xavier; Iung, Bernard; Alla, François; Chirouze, Catherine; Selton-Suty, Christine; Hoen, Bruno; Sinagra, Gianfranco; Delahaye, François; Tattevin, Pierre; Le Moing, Vincent; Pappalardo, Aniello; Chocron, Sidney

    2017-07-20

    Aspecific scoring systems are used to predict the risk of death postsurgery in patients with infective endocarditis (IE). The purpose of the present study was both to analyze the risk factors for in-hospital death, which complicates surgery for IE, and to create a mortality risk score based on the results of this analysis. Outcomes of 361 consecutive patients (mean age, 59.1±15.4 years) who had undergone surgery for IE in 8 European centers of cardiac surgery were recorded prospectively, and a risk factor analysis (multivariable logistic regression) for in-hospital death was performed. The discriminatory power of a new predictive scoring system was assessed with the receiver operating characteristic curve analysis. Score validation procedures were carried out. Fifty-six (15.5%) patients died postsurgery. BMI >27 kg/m 2 (odds ratio [OR], 1.79; P =0.049), estimated glomerular filtration rate <50 mL/min (OR, 3.52; P <0.0001), New York Heart Association class IV (OR, 2.11; P =0.024), systolic pulmonary artery pressure >55 mm Hg (OR, 1.78; P =0.032), and critical state (OR, 2.37; P =0.017) were independent predictors of in-hospital death. A scoring system was devised to predict in-hospital death postsurgery for IE (area under the receiver operating characteristic curve, 0.780; 95% CI, 0.734-0.822). The score performed better than 5 of 6 scoring systems for in-hospital death after cardiac surgery that were considered. A simple scoring system based on risk factors for in-hospital death was specifically created to predict mortality risk postsurgery in patients with IE. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  19. Standardized reporting of resection technique during nephron-sparing surgery: the surface-intermediate-base margin score.

    PubMed

    Minervini, Andrea; Carini, Marco; Uzzo, Robert G; Campi, Riccardo; Smaldone, Marc C; Kutikov, Alexander

    2014-11-01

    A standardized reporting system of nephron-sparing surgery resection techniques is lacking. The surface-intermediate-base scoring system represents a formal reporting instrument to assist in interpretation of reported data and to facilitate comparisons in the urologic literature. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. Evaluation of modified Alvarado scoring system and RIPASA scoring system as diagnostic tools of acute appendicitis.

    PubMed

    Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah

    2017-01-01

    Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (P<0.001) for both scoring systems. Based on the results of this study, the RIPASA score is a simple scoring system with better sensitivity and specificity than the modified Alvarado scoring system in Asian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado scoring system for Kuwait population.

  1. Wound center facility billing: A retrospective analysis of time, wound size, and acuity scoring for determining facility level of service.

    PubMed

    Fife, Caroline E; Walker, David; Farrow, Wade; Otto, Gordon

    2007-01-01

    Outpatient wound center facility reimbursement for Medicare beneficiaries can be a challenge to determine and obtain. To compare methods of calculating facility service levels for outpatient wound centers and to demonstrate the advantages of an acuity-based billing system (one that incorporates components of facility work that is non-reimbursable by procedure codes and that represents an activity-based costing approach to medical billing), a retrospective study of 5,098 patient encounters contained in a wound care-specific electronic medical record database was conducted. Approximately 500 patient visits to the outpatient wound center of a Texas regional hospital between April 2003 and November 2004 were categorized by service level in documentation and facility management software. Visits previously billed using a time-based system were compared to the Centers for Medicare and Medicaid Services' proposed three-tiered wound size-based system. The time-based system also was compared to an acuity-based scoring system. The Pearson correlation coefficient between billed level of service by time and estimated level of service by acuity was 0.442 and the majority of follow-up visits were billed as Level 3 and above (on a time level of 1 to 5) , confirming that time is not a surrogate for actual work performed. Wound size also was found to be unrelated to service level (Pearson correlation = 0.017) and 97% of wound areas were < 100 cm2. The acuity-based scoring system produced a near-normal distribution of results, producing more mid-range billings than extremes; no other method produced this distribution. Hospital-based outpatient wound centers should develop, review, and refine acuity score-based models on which to determine billed level of service.

  2. Histopathological grading of breast ductal carcinoma in situ: validation of a web-based survey through intra-observer reproducibility analysis.

    PubMed

    Schuh, Fernando; Biazús, Jorge Villanova; Resetkova, Erika; Benfica, Camila Zanella; Ventura, Alessandra de Freitas; Uchoa, Diego; Graudenz, Márcia; Edelweiss, Maria Isabel Albano

    2015-07-10

    Histopathological grading diagnosis of ductal carcinoma in situ (DCIS) of the breast may be very difficult even for experts, and it is important for therapeutic decisions. The challenge may be due to the inaccurate and/or subjective application of the diagnosis criteria. The aim of this study was to investigate the intra-observer agreement between a traditional method and a developed web-based questionnaire for scoring breast DCIS. A cross-sectional study was carried out to evaluate the diagnostic agreement of an electronic questionnaire and its point scoring system with the subjective reading of digital images for 3 different DCIS grading systems: Holland, Van Nuys and modified Black nuclear grade system. Three pathologists analyzed the same set of digitized images from 43 DCIS cases using two different web-based programs. In the first phase, they accessed a website with a newly created questionnaire and scoring system developed to allow the determination of the histological grade of the cases. After at least 6 months, the pathologists read again the same images, but without the help of the questionnaire, indicating subjectively the diagnoses. The intra-observer agreement analysis was employed to validate this innovative web-based survey. Overall, diagnostic reproducibility was similar for all histologic grading classification systems, with kappa values of 0.57 ± 0.10, 0.67 ± 0.09 and 0.67 ± 0.09 for Holland, Van Nuys classification and modified Black nuclear grade system respectively. Only two 2-step diagnostic disagreements were found, one for Holland and another for Van Nuys. Both cases were superestimated by the web-based survey. The diagnostic agreement between the web-based questionnaire and a traditional method, both using digital images, is moderate to good for Holland, Van Nuys and modified Black nuclear grade system. The use of a scoring point system does not appear to pose a major risk of presenting large (2-step) diagnostic disagreements. These findings indicate that the use of this point scoring system in this web-based survey to grade objectively DCIS lesions is a useful diagnostic tool.

  3. Noninvasive scoring system for significant inflammation related to chronic hepatitis B

    NASA Astrophysics Data System (ADS)

    Hong, Mei-Zhu; Ye, Linglong; Jin, Li-Xin; Ren, Yan-Dan; Yu, Xiao-Fang; Liu, Xiao-Bin; Zhang, Ru-Mian; Fang, Kuangnan; Pan, Jin-Shui

    2017-03-01

    Although a liver stiffness measurement-based model can precisely predict significant intrahepatic inflammation, transient elastography is not commonly available in a primary care center. Additionally, high body mass index and bilirubinemia have notable effects on the accuracy of transient elastography. The present study aimed to create a noninvasive scoring system for the prediction of intrahepatic inflammatory activity related to chronic hepatitis B, without the aid of transient elastography. A total of 396 patients with chronic hepatitis B were enrolled in the present study. Liver biopsies were performed, liver histology was scored using the Scheuer scoring system, and serum markers and liver function were investigated. Inflammatory activity scoring models were constructed for both hepatitis B envelope antigen (+) and hepatitis B envelope antigen (-) patients. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were 86.00%, 84.80%, 62.32%, 95.39%, and 0.9219, respectively, in the hepatitis B envelope antigen (+) group and 91.89%, 89.86%, 70.83%, 97.64%, and 0.9691, respectively, in the hepatitis B envelope antigen (-) group. Significant inflammation related to chronic hepatitis B can be predicted with satisfactory accuracy by using our logistic regression-based scoring system.

  4. Comparison of ISS, NISS, and RTS score as predictor of mortality in pediatric fall.

    PubMed

    Soni, Kapil Dev; Mahindrakar, Santosh; Gupta, Amit; Kumar, Subodh; Sagar, Sushma; Jhakal, Ashish

    2017-01-01

    Studies to identify an ideal trauma score tool representing prediction of outcomes of the pediatric fall patient remains elusive. Our study was undertaken to identify better predictor of mortality in the pediatric fall patients. Data was retrieved from prospectively maintained trauma registry project at level 1 trauma center developed as part of Multicentric Project-Towards Improving Trauma Care Outcomes (TITCO) in India. Single center data retrieved from a prospectively maintained trauma registry at a level 1 trauma center, New Delhi, for a period ranging from 1 October 2013 to 17 February 2015 was evaluated. Standard anatomic scores Injury Severity Score (ISS) and New Injury Severity Score (NISS) were compared with physiologic score Revised Trauma Score (RTS) using receiver operating curve (ROC). Heart rate and RTS had a statistical difference among the survivors to nonsurvivors. ISS, NISS, and RTS were having 50, 50, and 86% of area under the curve on ROCs, and RTS was statistically significant among them. Physiologically based trauma score systems (RTS) are much better predictors of inhospital mortality in comparison to anatomical based scoring systems (ISS and NISS) for unintentional pediatric falls.

  5. [Diagnostic value of integral scoring systems in assessing the severity of acute pancreatitis and patient's condition].

    PubMed

    Vinnik, Y S; Dunaevskaya, S S; Antufrieva, D A

    2015-01-01

    The aim of the study was to evaluate the diagnostic value of specific and nonspecific scoring systems Tolstoy-Krasnogorov score, Ranson, BISAP, Glasgow, MODS 2, APACHE II and CTSI, which used at urgent pancreatology for estimation the severity of acute pancreatitis and status of patient. 1550 case reports of patients which had inpatient surgical treatment at Road clinical hospital at the station Krasnoyarsk from 2009 till 2013 were analyzed. Diagnosis of severe acute pancreatitis and its complications were determined based on anamnestic data, physical exami- nation, clinical indexes, ultrasonic examination and computed tomography angiography. Specific and nonspecific scores (scoring system of estimation by Tolstoy-Krasnogorov, Ranson, Glasgow, BISAP, MODS 2, APACHE II, CTSI) were used for estimation the severity of acute pancreatitis and patient's general condition. Effectiveness of these scoring systems was determined based on some parameters: accuracy (Ac), sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV). Most valuables score for estimation of acute pancreatitis's severity is BISAP (Se--98.10%), for estimation of organ failure--MODS 2 (Sp--100%, PPV--100%) and APACHE II (Sp--100%, PPV--100%), for detection of pancreatonecrosis sings--CTSI (Sp--100%, NPV--100%), for estimation of need for intensive care--MODS 2 (Sp--100%, PPV--100%, NPV--96.29%) and APACHE II (Sp--100%, PPV--100%, NPV--97.21%), for prediction of lethality--MODS 2 (Se-- 100%, Sp--98.14%, NPV--100%) and APACHE II (Se--95.00%, NPV-.99.86%). Most effective scores for estimation of acute pancreatitis's severity are Score of estimation by Tolstoy-Krasnogorov, Ranson, Glasgow and BISAP Scoring systems MODS 2, APACHE I high specificity and positive predictive value allow using it at clinical practice.

  6. AVQS: Attack Route-Based Vulnerability Quantification Scheme for Smart Grid

    PubMed Central

    Lim, Hyunwoo; Lee, Seokjun; Shon, Taeshik

    2014-01-01

    A smart grid is a large, consolidated electrical grid system that includes heterogeneous networks and systems. Based on the data, a smart grid system has a potential security threat in its network connectivity. To solve this problem, we develop and apply a novel scheme to measure the vulnerability in a smart grid domain. Vulnerability quantification can be the first step in security analysis because it can help prioritize the security problems. However, existing vulnerability quantification schemes are not suitable for smart grid because they do not consider network vulnerabilities. We propose a novel attack route-based vulnerability quantification scheme using a network vulnerability score and an end-to-end security score, depending on the specific smart grid network environment to calculate the vulnerability score for a particular attack route. To evaluate the proposed approach, we derive several attack scenarios from the advanced metering infrastructure domain. The experimental results of the proposed approach and the existing common vulnerability scoring system clearly show that we need to consider network connectivity for more optimized vulnerability quantification. PMID:25152923

  7. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    PubMed

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (P<0.0001). The two-step scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  8. Development of a computed tomography-based scoring system for necrotizing soft-tissue infections.

    PubMed

    McGillicuddy, Edward A; Lischuk, Andrew W; Schuster, Kevin M; Kaplan, Lewis J; Maung, Adrian; Lui, Felix Y; Bokhari, S A Jamal; Davis, Kimberly A

    2011-04-01

    Necrotizing soft-tissue infections (NSTIs) are associated with significant morbidity and mortality, but a definitive nonsurgical diagnostic test remains elusive. Despite the widespread use of computed tomography (CT) as a diagnostic adjunct, there is little data that definitively correlate CT findings with the presence of NSTI. Our goal was the development of a CT-based scoring system to discriminate non-NSTI from NSTI. Patients older than 17 years undergoing CT for evaluation of soft-tissue infection at a tertiary care medical center over a 10-year period (2000-2009) were included. Abstracted data included comorbidities and social history, physical examination, laboratory findings, and operative and pathologic findings. NSTI was defined as soft-tissue necrosis in the dictated operative note or the accompanying pathology report. CT scans were reviewed by a radiologist blinded to clinical and laboratory data. A scoring system was developed and the area under the receiver operating characteristic curve was calculated. During the study period, 305 patients underwent CT scanning (57% men; mean age, 47.4 years). Forty-four patients (14.4%) evaluated had an NSTI. A scoring system was retrospectively developed (table). A score >6 points was 86.3% sensitive and 91.5% specific for the diagnosis of NSTI (positive predictive value, 63.3%; negative predictive value, 85.5%). The area under the receiver operating characteristic curve was 0.928 (95% confidence interval, 0.893-0.964). The mean score of the non-NSTI group was 2.74. We have developed a CT scoring system that is both sensitive and specific for the diagnosis of NSTIs. This system may allow clinicians to more accurately diagnose NSTIs. Prospective validation of this scoring system is planned.

  9. Development and Validation of a Risk Scoring System for Severe Acute Lower Gastrointestinal Bleeding.

    PubMed

    Aoki, Tomonori; Nagata, Naoyoshi; Shimbo, Takuro; Niikura, Ryota; Sakurai, Toshiyuki; Moriyasu, Shiori; Okubo, Hidetaka; Sekine, Katsunori; Watanabe, Kazuhiro; Yokoi, Chizu; Yanase, Mikio; Akiyama, Junichi; Mizokami, Masashi; Uemura, Naomi

    2016-11-01

    We aimed to develop and validate a risk scoring system to determine the risk of severe lower gastrointestinal bleeding (LGIB) and predict patient outcomes. We first performed a retrospective analysis of data from 439 patients emergently hospitalized for acute LGIB at the National Center for Global Health and Medicine in Japan, from January 2009 through December 2013. We used data on comorbidities, medication, presenting symptoms, and vital signs, and laboratory test results to develop a scoring system for severe LGIB (defined as continuous and/or recurrent bleeding). We validated the risk score in a prospective study of 161 patients with acute LGIB admitted to the same center from April 2014 through April 2015. We assessed the system's accuracy in predicting patient outcome using area under the receiver operating characteristics curve (AUC) analysis. All patients underwent colonoscopy. In the first study, 29% of the patients developed severe LGIB. We devised a risk scoring system based on nonsteroidal anti-inflammatory drugs use, no diarrhea, no abdominal tenderness, blood pressure of 100 mm Hg or lower, antiplatelet drugs use, albumin level less than 3.0 g/dL, disease scores of 2 or higher, and syncope (NOBLADS), which all were independent correlates of severe LGIB. Severe LGIB developed in 75.7% of patients with scores of 5 or higher compared with 2% of patients without any of the factors correlated with severe LGIB (P < .001). The NOBLADS score determined the severity of LGIB with an AUC value of 0.77. In the validation (second) study, severe LGIB developed in 35% of patients; the NOBLADS score predicted the severity of LGIB with an AUC value of 0.76. Higher NOBLADS scores were associated with a requirement for blood transfusion, longer hospital stay, and intervention (P < .05 for trend). We developed and validated a scoring system for risk of severe LGIB based on 8 factors (NOBLADS score). The system also determined the risk for blood transfusion, longer hospital stay, and intervention. It might be used in decision making regarding intervention and management. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Quantum neural network based machine translator for Hindi to English.

    PubMed

    Narayan, Ravi; Singh, V P; Chakraverty, S

    2014-01-01

    This paper presents the machine learning based machine translation system for Hindi to English, which learns the semantically correct corpus. The quantum neural based pattern recognizer is used to recognize and learn the pattern of corpus, using the information of part of speech of individual word in the corpus, like a human. The system performs the machine translation using its knowledge gained during the learning by inputting the pair of sentences of Devnagri-Hindi and English. To analyze the effectiveness of the proposed approach, 2600 sentences have been evaluated during simulation and evaluation. The accuracy achieved on BLEU score is 0.7502, on NIST score is 6.5773, on ROUGE-L score is 0.9233, and on METEOR score is 0.5456, which is significantly higher in comparison with Google Translation and Bing Translation for Hindi to English Machine Translation.

  11. Wearable PPG sensor based alertness scoring system.

    PubMed

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  12. The assignment of scores procedure for ordinal categorical data.

    PubMed

    Chen, Han-Ching; Wang, Nae-Sheng

    2014-01-01

    Ordinal data are the most frequently encountered type of data in the social sciences. Many statistical methods can be used to process such data. One common method is to assign scores to the data, convert them into interval data, and further perform statistical analysis. There are several authors who have recently developed assigning score methods to assign scores to ordered categorical data. This paper proposes an approach that defines an assigning score system for an ordinal categorical variable based on underlying continuous latent distribution with interpretation by using three case study examples. The results show that the proposed score system is well for skewed ordinal categorical data.

  13. Semi-automatic computerized approach to radiological quantification in rheumatoid arthritis

    NASA Astrophysics Data System (ADS)

    Steiner, Wolfgang; Schoeffmann, Sylvia; Prommegger, Andrea; Boegl, Karl; Klinger, Thomas; Peloschek, Philipp; Kainberger, Franz

    2004-04-01

    Rheumatoid Arthritis (RA) is a common systemic disease predominantly involving the joints. Precise diagnosis and follow-up therapy requires objective quantification. For this purpose, radiological analyses using standardized scoring systems are considered to be the most appropriate method. The aim of our study is to develop a semi-automatic image analysis software, especially applicable for scoring of joints in rheumatic disorders. The X-Ray RheumaCoach software delivers various scoring systems (Larsen-Score and Ratingen-Rau-Score) which can be applied by the scorer. In addition to the qualitative assessment of joints performed by the radiologist, a semi-automatic image analysis for joint detection and measurements of bone diameters and swollen tissue supports the image assessment process. More than 3000 radiographs from hands and feet of more than 200 RA patients were collected, analyzed, and statistically evaluated. Radiographs were quantified using conventional paper-based Larsen score and the X-Ray RheumaCoach software. The use of the software shortened the scoring time by about 25 percent and reduced the rate of erroneous scorings in all our studies. Compared to paper-based scoring methods, the X-Ray RheumaCoach software offers several advantages: (i) Structured data analysis and input that minimizes variance by standardization, (ii) faster and more precise calculation of sum scores and indices, (iii) permanent data storing and fast access to the software"s database, (iv) the possibility of cross-calculation to other scores, (v) semi-automatic assessment of images, and (vii) reliable documentation of results in the form of graphical printouts.

  14. Nurse-patient assignment models considering patient acuity metrics and nurses' perceived workload.

    PubMed

    Sir, Mustafa Y; Dundar, Bayram; Barker Steege, Linsey M; Pasupathy, Kalyan S

    2015-06-01

    Patient classification systems (PCSs) are commonly used in nursing units to assess how many nursing care hours are needed to care for patients. These systems then provide staffing and nurse-patient assignment recommendations for a given patient census based on these acuity scores. Our hypothesis is that such systems do not accurately capture workload and we conduct an experiment to test this hypothesis. Specifically, we conducted a survey study to capture nurses' perception of workload in an inpatient unit. Forty five nurses from oncology and surgery units completed the survey and rated the impact of patient acuity indicators on their perceived workload using a six-point Likert scale. These ratings were used to calculate a workload score for an individual nurse given a set of patient acuity indicators. The approach offers optimization models (prescriptive analytics), which use patient acuity indicators from a commercial PCS as well as a survey-based nurse workload score. The models assign patients to nurses in a balanced manner by distributing acuity scores from the PCS and survey-based perceived workload. Numerical results suggest that the proposed nurse-patient assignment models achieve a balanced assignment and lower overall survey-based perceived workload compared to the assignment based solely on acuity scores from the PCS. This results in an improvement of perceived workload that is upwards of five percent. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Integration of a knowledge-based system and a clinical documentation system via a data dictionary.

    PubMed

    Eich, H P; Ohmann, C; Keim, E; Lang, K

    1997-01-01

    This paper describes the design and realisation of a knowledge-based system and a clinical documentation system linked via a data dictionary. The software was developed as a shell with object oriented methods and C++ for IBM-compatible PC's and WINDOWS 3.1/95. The data dictionary covers terminology and document objects with relations to external classifications. It controls the terminology in the documentation program with form-based entry of clinical documents and in the knowledge-based system with scores and rules. The software was applied to the clinical field of acute abdominal pain by implementing a data dictionary with 580 terminology objects, 501 document objects, and 2136 links; a documentation module with 8 clinical documents and a knowledge-based system with 10 scores and 7 sets of rules.

  16. Automated outcome scoring in a virtual reality simulator for endodontic surgery.

    PubMed

    Yin, Myat Su; Haddawy, Peter; Suebnukarn, Siriwan; Rhienmora, Phattanapon

    2018-01-01

    We address the problem of automated outcome assessment in a virtual reality (VR) simulator for endodontic surgery. Outcome assessment is an essential component of any system that provides formative feedback, which requires assessing the outcome, relating it to the procedure, and communicating in a language natural to dental students. This study takes a first step toward automated generation of such comprehensive feedback. Virtual reference templates are computed based on tooth anatomy and the outcome is assessed with a 3D score cube volume which consists of voxel-level non-linear weighted scores based on the templates. The detailed scores are transformed into standard scoring language used by dental schools. The system was evaluated on fifteen outcome samples that contained optimal results and those with errors including perforation of the walls, floor, and both, as well as various combinations of major and minor over and under drilling errors. Five endodontists who had professional training and varying levels of experiences in root canal treatment participated as raters in the experiment. Results from evaluation of our system with expert endodontists show a high degree of agreement with expert scores (information based measure of disagreement 0.04-0.21). At the same time they show some disagreement among human expert scores, reflecting the subjective nature of human outcome scoring. The discriminatory power of the AOS scores analyzed with three grade tiers (A, B, C) using the area under the receiver operating characteristic curve (AUC). The AUC values are generally highest for the {AB: C} cutoff which is cutoff at the boundary between clinically acceptable (B) and clinically unacceptable (C) grades. The objective consistency of computed scores and high degree of agreement with experts make the proposed system a promising addition to existing VR simulators. The translation of detailed level scores into terminology commonly used in dental surgery supports natural communication with students and instructors. With the reference virtual templates created automatically, the approach is robust and is applicable in scoring the outcome of any dental surgery procedure involving the act of drilling. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Automated determination of wakefulness and sleep in rats based on non-invasively acquired measures of movement and respiratory activity

    PubMed Central

    Zeng, Tao; Mott, Christopher; Mollicone, Daniel; Sanford, Larry D.

    2012-01-01

    The current standard for monitoring sleep in rats requires labor intensive surgical procedures and the implantation of chronic electrodes which have the potential to impact behavior and sleep. With the goal of developing a non-invasive method to determine sleep and wakefulness, we constructed a non-contact monitoring system to measure movement and respiratory activity using signals acquired with pulse Doppler radar and from digitized video analysis. A set of 23 frequency and time-domain features were derived from these signals and were calculated in 10 s epochs. Based on these features, a classification method for automated scoring of wakefulness, non-rapid eye movement sleep (NREM) and REM in rats was developed using a support vector machine (SVM). We then assessed the utility of the automated scoring system in discriminating wakefulness and sleep by comparing the results to standard scoring of wakefulness and sleep based on concurrently recorded EEG and EMG. Agreement between SVM automated scoring based on selected features and visual scores based on EEG and EMG were approximately 91% for wakefulness, 84% for NREM and 70% for REM. The results indicate that automated scoring based on non-invasively acquired movement and respiratory activity will be useful for studies requiring discrimination of wakefulness and sleep. However, additional information or signals will be needed to improve discrimination of NREM and REM episodes within sleep. PMID:22178621

  18. Is Effective Teaching Stable?

    ERIC Educational Resources Information Center

    Patrick, Helen; Mantzicopoulos, Panayota

    2016-01-01

    The authors examined the ecological validity of using observation-based scores to evaluate individual teachers' effectiveness, mirroring their use by school administrators. Using the Classroom Assessment Scoring System, the authors asked (a) how similar are teachers' emotional support, classroom organization, and instructional support scores from…

  19. A KARAOKE System Singing Evaluation Method that More Closely Matches Human Evaluation

    NASA Astrophysics Data System (ADS)

    Takeuchi, Hideyo; Hoguro, Masahiro; Umezaki, Taizo

    KARAOKE is a popular amusement for old and young. Many KARAOKE machines have singing evaluation function. However, it is often said that the scores given by KARAOKE machines do not match human evaluation. In this paper a KARAOKE scoring method strongly correlated with human evaluation is proposed. This paper proposes a way to evaluate songs based on the distance between singing pitch and musical scale, employing a vibrato extraction method based on template matching of spectrum. The results show that correlation coefficients between scores given by the proposed system and human evaluation are -0.76∼-0.89.

  20. 2D and 3D MOCART scoring systems assessed by 9.4 T high-field MRI correlate with elementary and complex histological scoring systems in a translational model of osteochondral repair.

    PubMed

    Goebel, L; Zurakowski, D; Müller, A; Pape, D; Cucchiarini, M; Madry, H

    2014-10-01

    To compare the 2D and 3D MOCART system obtained with 9.4 T high-field magnetic resonance imaging (MRI) for the ex vivo analysis of osteochondral repair in a translational model and to correlate the data with semiquantitative histological analysis. Osteochondral samples representing all levels of repair (sheep medial femoral condyles; n = 38) were scanned in a 9.4 T high-field MRI. The 2D and adapted 3D MOCART systems were used for grading after point allocation to each category. Each score was correlated with corresponding reconstructions between both MOCART systems. Data were next correlated with corresponding categories of an elementary (Wakitani) and a complex (Sellers) histological scoring system as gold standards. Correlations between most 2D and 3D MOCART score categories were high, while mean total point values of 3D MOCART scores tended to be 15.8-16.1 points higher compared to the 2D MOCART scores based on a Bland-Altman analysis. "Defect fill" and "total points" of both MOCART scores correlated with corresponding categories of Wakitani and Sellers scores (all P ≤ 0.05). "Subchondral bone plate" also correlated between 3D MOCART and Sellers scores (P < 0.001). Most categories of the 2D and 3D MOCART systems correlate, while total scores were generally higher using the 3D MOCART system. Structural categories "total points" and "defect fill" can reliably be assessed by 9.4 T MRI evaluation using either system, "subchondral bone plate" using the 3D MOCART score. High-field MRI is valuable to objectively evaluate osteochondral repair in translational settings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. A Preliminary Investigation into the Effect of Standards-Based Grading on the Academic Performance of African-American Students

    NASA Astrophysics Data System (ADS)

    Bradbury-Bailey, Mary

    With the implementation of No Child Left Behind came a wave of educational reform intended for those working with student populations whose academic performance seemed to indicate an alienation from the educational process. Central to these reforms was the implementation of standards-based instruction and their accompanying standardized assessments; however, in one area reform seemed nonexistent---the teacher's gradebook. (Erickson, 2010, Marzano, 2006; Scriffiny, 2008). Given the link between the grading process and achievement motivation, Ames (1992) suggested the use of practices that promote mastery goal orientation. The purpose of this study was to examine the impact of standards-based grading system as a factor contributing to mastery goal orientation on the academic performance of urban African American students. To determine the degree of impact, this study first compared the course content averages and End-of-Course-Test (EOCT) scores for science classes using a traditional grading system to those using a standards-based grading system by employing an Analysis of Covariance (ANCOVA). While there was an increase in all grading areas, two showed a significant difference---the Physical Science course content average (p = 0.024) and ix the Biology EOCT scores (p = 0.0876). These gains suggest that standards-based grading can have a positive impact on the academic performance of African American students. Secondly, this study examined the correlation between the course content averages and the EOCT scores for both the traditional and standards-based grading system; for both Physical Science and Biology, there was a stronger correlation between these two scores for the standards-based grading system.

  2. Methodologies for semiquantitative evaluation of hip osteoarthritis by magnetic resonance imaging: approaches based on the whole organ and focused on active lesions.

    PubMed

    Jaremko, Jacob L; Lambert, Robert G W; Zubler, Veronika; Weber, Ulrich; Loeuille, Damien; Roemer, Frank W; Cibere, Jolanda; Pianta, Marcus; Gracey, David; Conaghan, Philip; Ostergaard, Mikkel; Maksymowych, Walter P

    2014-02-01

    As a wider variety of therapeutic options for osteoarthritis (OA) becomes available, there is an increasing need to objectively evaluate disease severity on magnetic resonance imaging (MRI). This is more technically challenging at the hip than at the knee, and as a result, few systematic scoring systems exist. The OMERACT (Outcome Measures in Rheumatology) filter of truth, discrimination, and feasibility can be used to validate image-based scoring systems. Our objective was (1) to review the imaging features relevant to the assessment of severity and progression of hip OA; and (2) to review currently used methods to grade these features in existing hip OA scoring systems. A systematic literature review was conducted. MEDLINE keyword search was performed for features of arthropathy (such as hip + bone marrow edema or lesion, synovitis, cyst, effusion, cartilage, etc.) and scoring system (hip + OA + MRI + score or grade), with a secondary manual search for additional references in the retrieved publications. Findings relevant to the severity of hip OA include imaging markers associated with inflammation (bone marrow lesion, synovitis, effusion), structural damage (cartilage loss, osteophytes, subchondral cysts, labral tears), and predisposing geometric factors (hip dysplasia, femoral-acetabular impingement). Two approaches to the semiquantitative assessment of hip OA are represented by Hip OA MRI Scoring System (HOAMS), a comprehensive whole organ assessment of nearly all findings, and the Hip Inflammation MRI Scoring System (HIMRISS), which selectively scores only active lesions (bone marrow lesion, synovitis/effusion). Validation is presently confined to limited assessment of reliability. Two methods for semiquantitative assessment of hip OA on MRI have been described and validation according to the OMERACT Filter is limited to evaluation of reliability.

  3. Measuring Provider Performance for Physicians Participating in the Merit-Based Incentive Payment System.

    PubMed

    Squitieri, Lee; Chung, Kevin C

    2017-07-01

    In 2017, the Centers for Medicare and Medicaid Services began requiring all eligible providers to participate in the Quality Payment Program or face financial reimbursement penalty. The Quality Payment Program outlines two paths for provider participation: the Merit-Based Incentive Payment System and Advanced Alternative Payment Models. For the first performance period beginning in January of 2017, the Centers for Medicare and Medicaid Services estimates that approximately 83 to 90 percent of eligible providers will not qualify for participation in an Advanced Alternative Payment Model and therefore must participate in the Merit-Based Incentive Payment System program. The Merit-Based Incentive Payment System path replaces existing quality-reporting programs and adds several new measures to evaluate providers using four categories of data: (1) quality, (2) cost/resource use, (3) improvement activities, and (4) advancing care information. These categories will be combined to calculate a weighted composite score for each provider or provider group. Composite Merit-Based Incentive Payment System scores based on 2017 performance data will be used to adjust reimbursed payment in 2019. In this article, the authors provide relevant background for understanding value-based provider performance measurement. The authors also discuss Merit-Based Incentive Payment System reporting requirements and scoring methodology to provide plastic surgeons with the necessary information to critically evaluate their own practice capabilities in the context of current performance metrics under the Quality Payment Program.

  4. The system evaluation for report writing skills of summary by HGA-SVM with Ontology: Medical case study in problem based learning

    NASA Astrophysics Data System (ADS)

    Yenaeng, Sasikanchana; Saelee, Somkid; Samai, Wirachai

    2018-01-01

    The system evaluation for report writing skills of summary by Hybrid Genetic Algorithm-Support Vector Machines (HGA-SVM) with Ontology of Medical Case Study in Problem Based Learning (PBL) is a system was developed as a guideline of scoring for the facilitators or medical teacher. The essay answers come from medical student of medical education courses in the nervous system motion and Behavior I and II subject, a third year medical student 20 groups of 9-10 people, the Faculty of Medicine in Prince of Songkla University (PSU). The audit committee have the opinion that the ratings of individual facilitators are inadequate, this system to solve such problems. In this paper proposes a development of the system evaluation for report writing skills of summary by HGA-SVM with Ontology of medical case study in PBL which the mean scores of machine learning score and humans (facilitators) score were not different at the significantly level .05 all 3 essay parts contain problem essay part, hypothesis essay part and learning objective essay part. The result show that, the average score all 3 essay parts that were not significantly different from the rate at the level of significance .05.

  5. Development and validation of a composite scoring system for robot-assisted surgical training--the Robotic Skills Assessment Score.

    PubMed

    Chowriappa, Ashirwad J; Shi, Yi; Raza, Syed Johar; Ahmed, Kamran; Stegemann, Andrew; Wilding, Gregory; Kaouk, Jihad; Peabody, James O; Menon, Mani; Hassett, James M; Kesavadas, Thenkurussi; Guru, Khurshid A

    2013-12-01

    A standardized scoring system does not exist in virtual reality-based assessment metrics to describe safe and crucial surgical skills in robot-assisted surgery. This study aims to develop an assessment score along with its construct validation. All subjects performed key tasks on previously validated Fundamental Skills of Robotic Surgery curriculum, which were recorded, and metrics were stored. After an expert consensus for the purpose of content validation (Delphi), critical safety determining procedural steps were identified from the Fundamental Skills of Robotic Surgery curriculum and a hierarchical task decomposition of multiple parameters using a variety of metrics was used to develop Robotic Skills Assessment Score (RSA-Score). Robotic Skills Assessment mainly focuses on safety in operative field, critical error, economy, bimanual dexterity, and time. Following, the RSA-Score was further evaluated for construct validation and feasibility. Spearman correlation tests performed between tasks using the RSA-Scores indicate no cross correlation. Wilcoxon rank sum tests were performed between the two groups. The proposed RSA-Score was evaluated on non-robotic surgeons (n = 15) and on expert-robotic surgeons (n = 12). The expert group demonstrated significantly better performance on all four tasks in comparison to the novice group. Validation of the RSA-Score in this study was carried out on the Robotic Surgical Simulator. The RSA-Score is a valid scoring system that could be incorporated in any virtual reality-based surgical simulator to achieve standardized assessment of fundamental surgical tents during robot-assisted surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Merit-Based Incentive Payment System (MIPS): Harsh Choices For Interventional Pain Management Physicians.

    PubMed

    Manchikanti, Laxmaiah; Helm Ii, Standiford; Benyamin, Ramsin M; Hirsch, Joshua A

    2016-01-01

    The Merit-based Incentive Payment System (MIPS) was created by the Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) to improve the health of all Americans by providing incentives and policies to improve patient health outcomes. MIPS combines 3 existing programs, Meaningful Use (MU), now called Advancing Care Information (ACI), contributing 25% of the composite score; Physician Quality Reporting System (PQRS), changed to Quality, contributing 50% of the composite score; and Value-based Payment (VBP) system to Resource Use or cost, contributing 10% of the composite score. Additionally, Clinical Practice Improvement Activities (CPIA), contributing 15% of the composite score, create multiple strategic goals to design incentives that drive movement toward delivery system reform principles with inclusion of Advanced Alternative Payment Models (APMs). Under the present proposal, the Centers for Medicare and Medicaid Services (CMS) has estimated approximately 30,000 to 90,000 providers from a total of over 761,000 providers will be exempt from MIPS. About 87% of solo practitioners and 70% of practitioners in groups of less than 10 will be subjected to negative payments or penalties ranging from 4% to 9%. In addition, MIPS also will affect a provider's reputation by making performance measures accessible to consumers and third-party physician rating Web sites.The MIPS composite performance scoring method, at least in theory, utilizes weights for each performance category, exceptional performance factors to earn bonuses, and incorporates the special circumstances of small practices.In conclusion, MIPS has the potential to affect practitioners negatively. Interventional Pain Medicine practitioners must understand the various MIPS measures and how they might participate in order to secure a brighter future. Medicare Access and CHIP Reauthorization Act of 2015, merit-based incentive payment system, quality performance measures, resource use, clinical practice improvement activities, advancing care information performance category.

  7. Nintendo Wii assessment of Hoehn and Yahr score with Parkinson's disease tremor.

    PubMed

    Koçer, Abdulkadir; Oktay, Ayse Betul

    2016-01-01

    Diagnosis of Parkinson's Disease (PD) by analyzing the resting tremor were much studied by using different accelerometer based methods, however the quantitative assessment of Hoehn and Yahr Scale (HYS) score with a machine learning based system has not been previously addressed. In this study, we aimed to propose a system to automatically assess the HYS score of patients with PD. The system was evaluated and tested on a dataset containing 55 subjects where 35 of them were patients and 20 of them were healthy controls. The resting tremor data were gathered with the 3 axis accelerometer of the Nintendo Wii (Wiimote). The clinical disability of the PD was graded from 1 to 5 by the HYS and tremor was recorded twice from the more affected side in each patient and from the dominant extremity in each control for a 60 seconds period. The HYS scores were learned with Support Vector Machines (SVM) from the features of the tremor data. Thirty-two of the subjects with PD were classified correctly and 18 of the normal subjects were also classified correctly by our system. The system had average 0.89 accuracy rate (Range: 81-100% changing according to grading by HYS). We compared quantitative measurements of hand tremor in PD patients, with staging of PD based on accelerometer data gathered using the Wii sensor. Our results showed that the machine learning based system with simple features could be helpful for diagnosis of PD and estimate HYS score. We believed that this portable and easy-to-use Wii sensor measure might also be applicable in the continuous monitoring of the resting tremor with small modifications in routine clinical use.

  8. Sepsis mortality prediction with the Quotient Basis Kernel.

    PubMed

    Ribas Ripoll, Vicent J; Vellido, Alfredo; Romero, Enrique; Ruiz-Rodríguez, Juan Carlos

    2014-05-01

    This paper presents an algorithm to assess the risk of death in patients with sepsis. Sepsis is a common clinical syndrome in the intensive care unit (ICU) that can lead to severe sepsis, a severe state of septic shock or multi-organ failure. The proposed algorithm may be implemented as part of a clinical decision support system that can be used in combination with the scores deployed in the ICU to improve the accuracy, sensitivity and specificity of mortality prediction for patients with sepsis. In this paper, we used the Simplified Acute Physiology Score (SAPS) for ICU patients and the Sequential Organ Failure Assessment (SOFA) to build our kernels and algorithms. In the proposed method, we embed the available data in a suitable feature space and use algorithms based on linear algebra, geometry and statistics for inference. We present a simplified version of the Fisher kernel (practical Fisher kernel for multinomial distributions), as well as a novel kernel that we named the Quotient Basis Kernel (QBK). These kernels are used as the basis for mortality prediction using soft-margin support vector machines. The two new kernels presented are compared against other generative kernels based on the Jensen-Shannon metric (centred, exponential and inverse) and other widely used kernels (linear, polynomial and Gaussian). Clinical relevance is also evaluated by comparing these results with logistic regression and the standard clinical prediction method based on the initial SAPS score. As described in this paper, we tested the new methods via cross-validation with a cohort of 400 test patients. The results obtained using our methods compare favourably with those obtained using alternative kernels (80.18% accuracy for the QBK) and the standard clinical prediction method, which are based on the basal SAPS score or logistic regression (71.32% and 71.55%, respectively). The QBK presented a sensitivity and specificity of 79.34% and 83.24%, which outperformed the other kernels analysed, logistic regression and the standard clinical prediction method based on the basal SAPS score. Several scoring systems for patients with sepsis have been introduced and developed over the last 30 years. They allow for the assessment of the severity of disease and provide an estimate of in-hospital mortality. Physiology-based scoring systems are applied to critically ill patients and have a number of advantages over diagnosis-based systems. Severity score systems are often used to stratify critically ill patients for possible inclusion in clinical trials. In this paper, we present an effective algorithm that combines both scoring methodologies for the assessment of death in patients with sepsis that can be used to improve the sensitivity and specificity of the currently available methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Evaluating Professionalism, Practice-Based Learning and Improvement, and Systems-Based Practice: Utilization of a Compliance Form and Correlation with Conflict Styles

    PubMed Central

    Ogunyemi, Dotun; Eno, Michelle; Rad, Steve; Fong, Alex; Alexander, Carolyn; Azziz, Ricardo

    2010-01-01

    Objective The purpose of this article was to develop and determine the utility of a compliance form in evaluating and teaching the Accreditation Council for Graduate Medical Education competencies of professionalism, practice-based learning and improvement, and systems-based practice. Methods In 2006, we introduced a 17-item compliance form in an obstetrics and gynecology residency program. The form prospectively monitored residents on attendance at required activities (5 items), accountability of required obligations (9 items), and completion of assigned projects (3 items). Scores were compared to faculty evaluations of residents, resident status as a contributor or a concerning resident, and to the residents' conflict styles, using the Thomas-Kilmann Conflict MODE Instrument. Results Our analysis of 18 residents for academic year 2007–2008 showed a mean (standard error of mean) of 577 (65.3) for postgraduate year (PGY)-1, 692 (42.4) for PGY-2, 535 (23.3) for PGY-3, and 651.6 (37.4) for PGY-4. Non-Hispanic white residents had significantly higher scores on compliance, faculty evaluations on interpersonal and communication skills, and competence in systems-based practice. Contributing residents had significantly higher scores on compliance compared with concerning residents. Senior residents had significantly higher accountability scores compared with junior residents, and junior residents had increased project completion scores. Attendance scores increased and accountability scores decreased significantly between the first and second 6 months of the academic year. There were positive correlations between compliance scores with competing and collaborating conflict styles, and significant negative correlations between compliance with avoiding and accommodating conflict styles. Conclusions Maintaining a compliance form allows residents and residency programs to focus on issues that affect performance and facilitate assessment of the ACGME competencies. Postgraduate year, behavior, and conflict styles appear to be associated with compliance. A lack of association with faculty evaluations suggests measurement of different perceptions of residents' behavior. PMID:21976093

  10. Evaluating professionalism, practice-based learning and improvement, and systems-based practice: utilization of a compliance form and correlation with conflict styles.

    PubMed

    Ogunyemi, Dotun; Eno, Michelle; Rad, Steve; Fong, Alex; Alexander, Carolyn; Azziz, Ricardo

    2010-09-01

    The purpose of this article was to develop and determine the utility of a compliance form in evaluating and teaching the Accreditation Council for Graduate Medical Education competencies of professionalism, practice-based learning and improvement, and systems-based practice. In 2006, we introduced a 17-item compliance form in an obstetrics and gynecology residency program. The form prospectively monitored residents on attendance at required activities (5 items), accountability of required obligations (9 items), and completion of assigned projects (3 items). Scores were compared to faculty evaluations of residents, resident status as a contributor or a concerning resident, and to the residents' conflict styles, using the Thomas-Kilmann Conflict MODE Instrument. Our analysis of 18 residents for academic year 2007-2008 showed a mean (standard error of mean) of 577 (65.3) for postgraduate year (PGY)-1, 692 (42.4) for PGY-2, 535 (23.3) for PGY-3, and 651.6 (37.4) for PGY-4. Non-Hispanic white residents had significantly higher scores on compliance, faculty evaluations on interpersonal and communication skills, and competence in systems-based practice. Contributing residents had significantly higher scores on compliance compared with concerning residents. Senior residents had significantly higher accountability scores compared with junior residents, and junior residents had increased project completion scores. Attendance scores increased and accountability scores decreased significantly between the first and second 6 months of the academic year. There were positive correlations between compliance scores with competing and collaborating conflict styles, and significant negative correlations between compliance with avoiding and accommodating conflict styles. Maintaining a compliance form allows residents and residency programs to focus on issues that affect performance and facilitate assessment of the ACGME competencies. Postgraduate year, behavior, and conflict styles appear to be associated with compliance. A lack of association with faculty evaluations suggests measurement of different perceptions of residents' behavior.

  11. A reliable and cost effective approach for radiographic monitoring in nutritional rickets.

    PubMed

    Chatterjee, D; Gupta, V; Sharma, V; Sinha, B; Samanta, S

    2014-04-01

    Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg(-1)) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution.

  12. Quantum Neural Network Based Machine Translator for Hindi to English

    PubMed Central

    Singh, V. P.; Chakraverty, S.

    2014-01-01

    This paper presents the machine learning based machine translation system for Hindi to English, which learns the semantically correct corpus. The quantum neural based pattern recognizer is used to recognize and learn the pattern of corpus, using the information of part of speech of individual word in the corpus, like a human. The system performs the machine translation using its knowledge gained during the learning by inputting the pair of sentences of Devnagri-Hindi and English. To analyze the effectiveness of the proposed approach, 2600 sentences have been evaluated during simulation and evaluation. The accuracy achieved on BLEU score is 0.7502, on NIST score is 6.5773, on ROUGE-L score is 0.9233, and on METEOR score is 0.5456, which is significantly higher in comparison with Google Translation and Bing Translation for Hindi to English Machine Translation. PMID:24977198

  13. The R.I.R.S. scoring system: An innovative scoring system for predicting stone-free rate following retrograde intrarenal surgery.

    PubMed

    Xiao, Yinglong; Li, Deng; Chen, Lei; Xu, Yaoting; Zhang, Dingguo; Shao, Yi; Lu, Jun

    2017-11-21

    To establish and internally validate an innovative R.I.R.S. scoring system that allows urologists to preoperatively estimate the stone-free rate (SFR) after retrograde intrarenal surgery (RIRS). This study included 382 eligible samples from a total 573 patients who underwent RIRS from January 2014 to December 2016. Four reproducible factors in the R.I.R.S. scoring system, including renal stone density, inferior pole stone, renal infundibular length and stone burden, were measured based on preoperative computed tomography of urography to evaluate the possibility of stone clearance after RIRS. The median cumulative diameter of the stones was 14 mm, and the interquartile range was 10 to 21. The SFR on postoperative day 1 in the present cohort was 61.5% (235 of 382), and the final SFR after 1 month was 73.6% (281 of 382). We established an innovative scoring system to evaluate SFR after RIRS using four preoperative characteristics. The range of the R.I.R.S. scoring system was 4 to 10. The overall score showed a great significance of stone-free status (p < 0.001). The area under the receiver operating characteristic curve of the R.I.R.S. scoring system was 0.904. The R.I.R.S. scoring system is associated with SFR after RIRS. This innovative scoring system can preoperatively assess treatment success after intrarenal surgery and can be used for preoperative surgical arrangement and comparisons of outcomes among different centers and within a center over time.

  14. Comparison of Different Scoring Systems Based on Both Donor and Recipient Characteristics for Predicting Outcome after Living Donor Liver Transplantation.

    PubMed

    Ma, Yucheng; Wang, Qing; Yang, Jiayin; Yan, Lunan

    2015-01-01

    In order to provide a good match between donor and recipient in liver transplantation, four scoring systems [the product of donor age and Model for End-stage Liver Disease score (D-MELD), the score to predict survival outcomes following liver transplantation (SOFT), the balance of risk score (BAR), and the transplant risk index (TRI)] based on both donor and recipient parameters were designed. This study was conducted to evaluate the performance of the four scores in living donor liver transplantation (LDLT) and compare them with the MELD score. The clinical data of 249 adult patients undergoing LDLT in our center were retrospectively evaluated. The area under the receiver operating characteristic curves (AUCs) of each score were calculated and compared at 1-, 3-, 6-month and 1-year after LDLT. The BAR at 1-, 3-, 6-month and 1-year after LDLT and the D-MELD and TRI at 1-, 3- and 6-month after LDLT showed acceptable performances in the prediction of survival (AUC>0.6), while the SOFT showed poor discrimination at 6-month after LDLT (AUC = 0.569). In addition, the D-MELD and BAR displayed positive correlations with the length of ICU stay (D-MELD, p = 0.025; BAR, p = 0.022). The SOFT was correlated with the time of mechanical ventilation (p = 0.022). The D-MELD, BAR and TRI provided acceptable performance in predicting survival after LDLT. However, even though these scoring systems were based on both donor and recipient parameters, only the BAR provided better performance than the MELD in predicting 1-year survival after LDLT.

  15. Comparison of Different Scoring Systems Based on Both Donor and Recipient Characteristics for Predicting Outcome after Living Donor Liver Transplantation

    PubMed Central

    2015-01-01

    Background and Objectives In order to provide a good match between donor and recipient in liver transplantation, four scoring systems [the product of donor age and Model for End-stage Liver Disease score (D-MELD), the score to predict survival outcomes following liver transplantation (SOFT), the balance of risk score (BAR), and the transplant risk index (TRI)] based on both donor and recipient parameters were designed. This study was conducted to evaluate the performance of the four scores in living donor liver transplantation (LDLT) and compare them with the MELD score. Patients and Methods The clinical data of 249 adult patients undergoing LDLT in our center were retrospectively evaluated. The area under the receiver operating characteristic curves (AUCs) of each score were calculated and compared at 1-, 3-, 6-month and 1-year after LDLT. Results The BAR at 1-, 3-, 6-month and 1-year after LDLT and the D-MELD and TRI at 1-, 3- and 6-month after LDLT showed acceptable performances in the prediction of survival (AUC>0.6), while the SOFT showed poor discrimination at 6-month after LDLT (AUC = 0.569). In addition, the D-MELD and BAR displayed positive correlations with the length of ICU stay (D-MELD, p = 0.025; BAR, p = 0.022). The SOFT was correlated with the time of mechanical ventilation (p = 0.022). Conclusion The D-MELD, BAR and TRI provided acceptable performance in predicting survival after LDLT. However, even though these scoring systems were based on both donor and recipient parameters, only the BAR provided better performance than the MELD in predicting 1-year survival after LDLT. PMID:26378786

  16. The SPOTS System: An Ocular Scoring System Optimized for Use in Modern Preclinical Drug Development and Toxicology.

    PubMed

    Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J

    2017-12-01

    To present a semiquantitative ocular scoring system comprising elements and criteria that address many of the limitations associated with systems commonly used in preclinical studies, providing enhanced cross-species applicability and predictive value in modern ocular drug and device development. Revisions to the ocular scoring systems of McDonald-Shadduck and Hackett-McDonald were conducted by board-certified veterinary ophthalmologists at Ocular Services On Demand (OSOD) over the execution of hundreds of in vivo preclinical ocular drug and device development studies and general toxicological investigations. This semiquantitative preclinical ocular toxicology scoring (SPOTS) system was driven by limitations of previously published systems identified by our group's recent review of slit lamp-based scoring systems in clinical ophthalmology, toxicology, and vision science. The SPOTS system provides scoring criteria for the anterior segment, posterior segment, and characterization of intravitreal test articles. Key elements include: standardized slit lamp settings; expansion of criteria to enhance applicability to nonrabbit species; refinement and disambiguation of scoring criteria for corneal opacity, fluorescein staining severity, and aqueous flare; introduction of novel criteria for scoring of aqueous and anterior vitreous cell; and introduction of criteria for findings observed with drugs/devices targeting the posterior segment. A modified Standardization of Uveitis Nomenclature (SUN) system is also introduced to facilitate accurate use of SUN's criteria in laboratory species. The SPOTS systems provide criteria that stand to enhance the applicability of semiquantitative scoring criteria to the full range of laboratory species, in the context of modern approaches to ocular therapeutics and drug delivery and drug and device development.

  17. Student-Centered Reliability, Concurrent Validity and Instructional Sensitivity in Scoring of Students' Concept Maps in a University Science Laboratory

    ERIC Educational Resources Information Center

    Kaya, Osman Nafiz; Kilic, Ziya

    2004-01-01

    Student-centered approach of scoring the concept maps consisted of three elements namely symbol system, individual portfolio and scoring scheme. We scored student-constructed concept maps based on 5 concept map criteria: validity of concepts, adequacy of propositions, significance of cross-links, relevancy of examples, and interconnectedness. With…

  18. Method Development for Clinical Comprehensive Evaluation of Pediatric Drugs Based on Multi-Criteria Decision Analysis: Application to Inhaled Corticosteroids for Children with Asthma.

    PubMed

    Yu, Yuncui; Jia, Lulu; Meng, Yao; Hu, Lihua; Liu, Yiwei; Nie, Xiaolu; Zhang, Meng; Zhang, Xuan; Han, Sheng; Peng, Xiaoxia; Wang, Xiaoling

    2018-04-01

    Establishing a comprehensive clinical evaluation system is critical in enacting national drug policy and promoting rational drug use. In China, the 'Clinical Comprehensive Evaluation System for Pediatric Drugs' (CCES-P) project, which aims to compare drugs based on clinical efficacy and cost effectiveness to help decision makers, was recently proposed; therefore, a systematic and objective method is required to guide the process. An evidence-based multi-criteria decision analysis model that involved an analytic hierarchy process (AHP) was developed, consisting of nine steps: (1) select the drugs to be reviewed; (2) establish the evaluation criterion system; (3) determine the criterion weight based on the AHP; (4) construct the evidence body for each drug under evaluation; (5) select comparative measures and calculate the original utility score; (6) place a common utility scale and calculate the standardized utility score; (7) calculate the comprehensive utility score; (8) rank the drugs; and (9) perform a sensitivity analysis. The model was applied to the evaluation of three different inhaled corticosteroids (ICSs) used for asthma management in children (a total of 16 drugs with different dosage forms and strengths or different manufacturers). By applying the drug analysis model, the 16 ICSs under review were successfully scored and evaluated. Budesonide suspension for inhalation (drug ID number: 7) ranked the highest, with comprehensive utility score of 80.23, followed by fluticasone propionate inhaled aerosol (drug ID number: 16), with a score of 79.59, and budesonide inhalation powder (drug ID number: 6), with a score of 78.98. In the sensitivity analysis, the ranking of the top five and lowest five drugs remains unchanged, suggesting this model is generally robust. An evidence-based drug evaluation model based on AHP was successfully developed. The model incorporates sufficient utility and flexibility for aiding the decision-making process, and can be a useful tool for the CCES-P.

  19. Research on Operation Assessment Method for Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  20. A Method of Evaluating Operation of Electric Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  1. Development of risk-based trading farm scoring system to assist with the control of bovine tuberculosis in cattle in England and Wales.

    PubMed

    Adkin, A; Brouwer, A; Simons, R R L; Smith, R P; Arnold, M E; Broughan, J; Kosmider, R; Downs, S H

    2016-01-01

    Identifying and ranking cattle herds with a higher risk of being or becoming infected on known risk factors can help target farm biosecurity, surveillance schemes and reduce spread through animal trading. This paper describes a quantitative approach to develop risk scores, based on the probability of infection in a herd with bovine tuberculosis (bTB), to be used in a risk-based trading (RBT) scheme in England and Wales. To produce a practical scoring system the risk factors included need to be simple and quick to understand, sufficiently informative and derived from centralised national databases to enable verification and assess compliance. A logistic regression identified herd history of bTB, local bTB prevalence, herd size and movements of animals onto farms in batches from high risk areas as being significantly associated with the probability of bTB infection on farm. Risk factors were assigned points using the estimated odds ratios to weight them. The farm risk score was defined as the sum of these individual points yielding a range from 1 to 5 and was calculated for each cattle farm that was trading animals in England and Wales at the start of a year. Within 12 months, of those farms tested, 30.3% of score 5 farms had a breakdown (sensitivity). Of farms scoring 1-4 only 5.4% incurred a breakdown (1-specificity). The use of this risk scoring system within RBT has the potential to reduce infected cattle movements; however, there are cost implications in ensuring that the information underpinning any system is accurate and up to date. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  2. A novel gene expression-based prognostic scoring system to predict survival in gastric cancer

    DOE PAGES

    Wang, Pin; Wang, Yunshan; Hang, Bo; ...

    2016-07-11

    Analysis of gene expression patterns in gastric cancer (GC) can help to identify a comprehensive panel of gene biomarkers for predicting clinical outcomes and to discover potential new therapeutic targets. Here, a multi-step bioinformatics analytic approach was developed to establish a novel prognostic scoring system for GC. We first identified 276 genes that were robustly differentially expressed between normal and GC tissues, of which, 249 were found to be significantly associated with overall survival (OS) by univariate Cox regression analysis. The biological functions of 249 genes are related to cell cycle, RNA/ncRNA process, acetylation and extracellular matrix organization. A networkmore » was generated for view of the gene expression architecture of 249 genes in 265 GCs. Finally, we applied a canonical discriminant analysis approach to identify a 53-gene signature and a prognostic scoring system was established based on a canonical discriminant function of 53 genes. The prognostic scores strongly predicted patients with GC to have either a poor or good OS. Our study raises the prospect that the practicality of GC patient prognosis can be assessed by this prognostic scoring system.« less

  3. A novel gene expression-based prognostic scoring system to predict survival in gastric cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Pin; Wang, Yunshan; Hang, Bo

    Analysis of gene expression patterns in gastric cancer (GC) can help to identify a comprehensive panel of gene biomarkers for predicting clinical outcomes and to discover potential new therapeutic targets. Here, a multi-step bioinformatics analytic approach was developed to establish a novel prognostic scoring system for GC. We first identified 276 genes that were robustly differentially expressed between normal and GC tissues, of which, 249 were found to be significantly associated with overall survival (OS) by univariate Cox regression analysis. The biological functions of 249 genes are related to cell cycle, RNA/ncRNA process, acetylation and extracellular matrix organization. A networkmore » was generated for view of the gene expression architecture of 249 genes in 265 GCs. Finally, we applied a canonical discriminant analysis approach to identify a 53-gene signature and a prognostic scoring system was established based on a canonical discriminant function of 53 genes. The prognostic scores strongly predicted patients with GC to have either a poor or good OS. Our study raises the prospect that the practicality of GC patient prognosis can be assessed by this prognostic scoring system.« less

  4. Application of modified R.E.N.A.L. nephrometry score system in evaluating the retroperitoneal partial nephrectomy for T1 renal cell carcinoma.

    PubMed

    Wang, Qinzhang; Qian, Biao; Li, Qiang; Ni, Zhao; Li, Yinglong; Wang, Xinmin

    2015-01-01

    This study aims to investigate the application of the modified R.E.N.A.L. nephrometry score system in evaluating the operation difficulty of retroperitoneal partial nephrectomy in T1 renal cell carcinoma patients. A total of 52 patients with T1 renal cell carcinoma were enrolled. They all had retroperitoneal partial nephrectomy. Their clinical data was retrospectively analyzed. R.E.N.A.L. nephrometry score system was modified based on the features of retroperitoneal partial nephrectomy. The specificity, sensitivity and Youden index were compared between R.E.N.A.L. nephrometry score system and the modified R.E.N.A.L. nephrometry score system. The effect of the modified R.E.N.A.L. nephrometry score system on perioperative outcomes was analyzed. Three degrees of operation difficulty were defined by the modified R.E.N.A.L. nephrometry score system, which included the low, medium and high degree of operation difficulty. The specificity, sensitivity and Youden index of the modified R.E.N.A.L. nephrometry score system were better than those of the original R.E.N.A.L. nephrometry score system. Compared with low degree of operation difficulty, patients with medium and high degree of operation difficulty had significantly higher levels of operative time, warm ischemia time, and intraoperative blood loss (P < 0.05). And, the levels of operative time, warm ischemia time, and intraoperative blood loss in patients with high degree were significantly higher than those in patients with medium degree (P < 0.05). The modified R.E.N.A.L. nephrometry score system has a good effect in evaluating the operation difficulty of retroperitoneal partial nephrectomy.

  5. Rapid automatic keyword extraction for information retrieval and analysis

    DOEpatents

    Rose, Stuart J [Richland, WA; Cowley,; E, Wendy [Richland, WA; Crow, Vernon L [Richland, WA; Cramer, Nicholas O [Richland, WA

    2012-03-06

    Methods and systems for rapid automatic keyword extraction for information retrieval and analysis. Embodiments can include parsing words in an individual document by delimiters, stop words, or both in order to identify candidate keywords. Word scores for each word within the candidate keywords are then calculated based on a function of co-occurrence degree, co-occurrence frequency, or both. Based on a function of the word scores for words within the candidate keyword, a keyword score is calculated for each of the candidate keywords. A portion of the candidate keywords are then extracted as keywords based, at least in part, on the candidate keywords having the highest keyword scores.

  6. Should predictive scores based on vital signs be used in the same way as those based on laboratory data? A hypothesis generating retrospective evaluation of in-hospital mortality by four different scoring systems.

    PubMed

    Kellett, John; Murray, Alan

    2016-05-01

    few studies have compared the discrimination of predictive scores of in-hospital mortality that used vital signs with those using laboratory results in different patient populations. a hypothesis generating retrospective observational cohort study. A score that only used vital signs was compared with three other scores that used laboratory changes in 44,985 medical and 20,432 surgical patients. the discrimination of the score based only on vital signs was highest for the prediction of in-hospital death within 24h. In contrast the, albeit lower, discrimination of scores based only on laboratory data remained constant for the prediction of death up to 30 days after hospital admission. Moreover, the discrimination of scores based only on laboratory data was higher in surgical than in medical patients. in acutely ill medical patients a vital sign based score appears to predict mortality within 24h better than scores using laboratory data. This may be because in acutely ill patients vital sign changes indicate how well a patient is responding to a current insult. In contrast, for patients without acute illness laboratory data may be a more valuable indication of the patient's capacity to respond to insults in the future. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Intelligent query by humming system based on score level fusion of multiple classifiers

    NASA Astrophysics Data System (ADS)

    Pyo Nam, Gi; Thu Trang Luong, Thi; Ha Nam, Hyun; Ryoung Park, Kang; Park, Sung-Joo

    2011-12-01

    Recently, the necessity for content-based music retrieval that can return results even if a user does not know information such as the title or singer has increased. Query-by-humming (QBH) systems have been introduced to address this need, as they allow the user to simply hum snatches of the tune to find the right song. Even though there have been many studies on QBH, few have combined multiple classifiers based on various fusion methods. Here we propose a new QBH system based on the score level fusion of multiple classifiers. This research is novel in the following three respects: three local classifiers [quantized binary (QB) code-based linear scaling (LS), pitch-based dynamic time warping (DTW), and LS] are employed; local maximum and minimum point-based LS and pitch distribution feature-based LS are used as global classifiers; and the combination of local and global classifiers based on the score level fusion by the PRODUCT rule is used to achieve enhanced matching accuracy. Experimental results with the 2006 MIREX QBSH and 2009 MIR-QBSH corpus databases show that the performance of the proposed method is better than that of single classifier and other fusion methods.

  8. A model-based reasoning approach to sensor placement for monitorability

    NASA Technical Reports Server (NTRS)

    Chien, Steve; Doyle, Richard; Homemdemello, Luiz

    1992-01-01

    An approach is presented to evaluating sensor placements to maximize monitorability of the target system while minimizing the number of sensors. The approach uses a model of the monitored system to score potential sensor placements on the basis of four monitorability criteria. The scores can then be analyzed to produce a recommended sensor set. An example from our NASA application domain is used to illustrate our model-based approach to sensor placement.

  9. Development and Evaluation of Strong-Campbell Interest Inventory Scales to Measure Interests of Military Occupational Specialties of the Marine Corps.

    DTIC Science & Technology

    1982-08-01

    though the two groups were different in terms of SC!I scientific interests and academic orientation scores (the aviation supply sample scored higher on...51 Chemists/Physicists 50 MARINE OFFICERS- COMUNICATION 49 MARINE OFFICERS-DATA SYSTEMS 48 Engineers 47 Biologists 46 Systems Analysts/Computer...Base ( Scientific and Technical Information Office) Commander, Air Force Human Resources Laboratory, Lowry Air Force Base (Technical Training Branch

  10. Development of a novel clinical scoring system for on-farm diagnosis of bovine respiratory disease in pre-weaned dairy calves.

    PubMed

    Love, William J; Lehenbauer, Terry W; Kass, Philip H; Van Eenennaam, Alison L; Aly, Sharif S

    2014-01-01

    Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves.

  11. Development of a novel clinical scoring system for on-farm diagnosis of bovine respiratory disease in pre-weaned dairy calves

    PubMed Central

    Love, William J.; Lehenbauer, Terry W.; Kass, Philip H.; Van Eenennaam, Alison L.

    2014-01-01

    Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves. PMID:24482759

  12. Structure refinement of membrane proteins via molecular dynamics simulations.

    PubMed

    Dutagaci, Bercem; Heo, Lim; Feig, Michael

    2018-07-01

    A refinement protocol based on physics-based techniques established for water soluble proteins is tested for membrane protein structures. Initial structures were generated by homology modeling and sampled via molecular dynamics simulations in explicit lipid bilayer and aqueous solvent systems. Snapshots from the simulations were selected based on scoring with either knowledge-based or implicit membrane-based scoring functions and averaged to obtain refined models. The protocol resulted in consistent and significant refinement of the membrane protein structures similar to the performance of refinement methods for soluble proteins. Refinement success was similar between sampling in the presence of lipid bilayers and aqueous solvent but the presence of lipid bilayers may benefit the improvement of lipid-facing residues. Scoring with knowledge-based functions (DFIRE and RWplus) was found to be as good as scoring using implicit membrane-based scoring functions suggesting that differences in internal packing is more important than orientations relative to the membrane during the refinement of membrane protein homology models. © 2018 Wiley Periodicals, Inc.

  13. Prognostic factors and scoring system for survival in colonic perforation.

    PubMed

    Komatsu, Shuhei; Shimomatsuya, Takumi; Nakajima, Masayuki; Amaya, Hirokazu; Kobuchi, Taketsune; Shiraishi, Susumu; Konishi, Sayuri; Ono, Susumu; Maruhashi, Kazuhiro

    2005-01-01

    No ideal and generally accepted prognostic factors and scoring systems exist to determine the prognosis of peritonitis associated with colonic perforation. This study was designed to investigate prognostic factors and evaluate the various scoring systems to allow identification of high-risk patients. Between 1996 and 2003, excluding iatrogenic and trauma cases, 26 consecutive patients underwent emergency operations for colorectal perforation and were selected for this retrospective study. Several clinical factors were analyzed as possible predictive factors, and APACHE II, SOFA, MPI, and MOF scores were calculated. The overall mortality was 26.9%. Compared with the survivors, non-survivors were found more frequently in Hinchey's stage III-IV, a low preoperative marker of pH, base excess (BE), and a low postoperative marker of white blood cell count, PaO2/FiO2 ratio, and renal output (24h). According to the logistic regression model, BE was a significant independent variable. Concerning the prognostic scoring systems, an APACHE II score of 19, a SOFA score of 8, an MPI score of 30, and an MOF score of 7 or more were significantly related to poor prognosis. Preoperative BE and postoperative white blood cell count were reliable prognostic factors and early classification using prognostic scoring systems at specific points in the disease process are useful to improve our understanding of the problems involved.

  14. PyParse: a semiautomated system for scoring spoken recall data.

    PubMed

    Solway, Alec; Geller, Aaron S; Sederberg, Per B; Kahana, Michael J

    2010-02-01

    Studies of human memory often generate data on the sequence and timing of recalled items, but scoring such data using conventional methods is difficult or impossible. We describe a Python-based semiautomated system that greatly simplifies this task. This software, called PyParse, can easily be used in conjunction with many common experiment authoring systems. Scored data is output in a simple ASCII format and can be accessed with the programming language of choice, allowing for the identification of features such as correct responses, prior-list intrusions, extra-list intrusions, and repetitions.

  15. Prognostic capability of different liver disease scoring systems for prediction of early mortality after transjugular intrahepatic portosystemic shunt creation.

    PubMed

    Gaba, Ron C; Couture, Patrick M; Bui, James T; Knuttinen, M Grace; Walzer, Natasha M; Kallwitz, Eric R; Berkes, Jamie L; Cotler, Scott J

    2013-03-01

    To compare the performance of various liver disease scoring systems in predicting early mortality after transjugular intrahepatic portosystemic shunt (TIPS) creation. In this single-institution retrospective study, eight scoring systems were used to grade liver disease in 211 patients (male-to-female ratio = 131:80; mean age, 54 y) before TIPS creation from 1999-2011. Scoring systems included bilirubin level, Child-Pugh (CP) score, Model for End-Stage Liver Disease (MELD) and Model for End-Stage Liver Disease sodium (MELD-Na) score, Emory score, prognostic index (PI), Acute Physiology and Chronic Health Evaluation (APACHE) 2 score, and Bonn TIPS early mortality (BOTEM) score. Medical record review was used to identify 30-day and 90-day clinical outcomes. The relationship of scoring parameters with mortality outcomes was assessed with multivariate analysis, and the relative ability of systems to predict mortality after TIPS creation was evaluated by comparing area under receiver operating characteristic (AUROC) curves. TIPS were successfully created for variceal hemorrhage (n = 121), ascites (n = 72), hepatic hydrothorax (n = 15), and portal vein thrombosis (n = 3). All scoring systems had a significant association with 30-day and 90-day mortality (P<.050 in each case) on multivariate analysis. Based on 30-day and 90-day AUROC, MELD (0.878, 0.816) and MELD-Na (0.863, 0.823) scores had the best capability to predict early mortality compared with bilirubin (0.786, 0.749), CP (0.822, 0.771), Emory (0.786, 0.681), PI (0.854, 0.760), APACHE 2 (0.836, 0.735), and BOTEM (0.798, 0.698), with statistical superiority over bilirubin, Emory, and BOTEM scores. Several liver disease scoring systems have prognostic value for early mortality after TIPS creation. MELD and MELD-Na scores most effectively predict survival after TIPS creation. Copyright © 2013. Published by Elsevier Inc.

  16. 42 CFR § 414.1370 - APM scoring standard under MIPS.

    Code of Federal Regulations, 2010 CFR

    2017-10-01

    ... SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Merit-Based Incentive Payment System and Alternative Payment Model Incentive § 414.1370 APM scoring... Participation List; (3) The APM bases payment on cost/utilization and quality measures; and (4) The APM is not...

  17. Classification of Airflow Limitation Based on z-Score Underestimates Mortality in Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Tejero, Elena; Prats, Eva; Casitas, Raquel; Galera, Raúl; Pardo, Paloma; Gavilán, Adelaida; Martínez-Cerón, Elisabet; Cubillos-Zapata, Carolina; Del Peso, Luis; García-Río, Francisco

    2017-08-01

    Global Lung Function Initiative recommends reporting lung function measures as z-score, and a classification of airflow limitation (AL) based on this parameter has recently been proposed. To evaluate the prognostic capacity of the AL classifications based on z-score or percentage predicted of FEV 1 in patients with chronic obstructive pulmonary disease (COPD). A cohort of 2,614 patients with COPD recruited outside the hospital setting was examined after a mean (± SD) of 57 ± 13 months of follow-up, totaling 10,322 person-years. All-cause mortality was analyzed, evaluating the predictive capacity of several AL staging systems. Based on Global Initiative for Chronic Obstructive Lung Disease guidelines, 461 patients (17.6%) had mild, 1,452 (55.5%) moderate, 590 (22.6%) severe, and 111 (4.2%) very severe AL. According to z-score classification, 66.3% of patients remained with the same severity, whereas 23.7% worsened and 10.0% improved. Unlike other staging systems, patients with severe AL according to z-score had higher mortality than those with very severe AL (increase of risk by 5.2 and 3.9 times compared with mild AL, respectively). The predictive capacity for 5-year survival was slightly higher for FEV 1 expressed as percentage of predicted than as z-score (area under the curve: 0.714-0.760 vs. 0.649-0.708, respectively). A severity-dependent relationship between AL grades by z-score and mortality was only detected in patients younger than age 60 years. In patients with COPD, the AL classification based on z-score predicts worse mortality than those based on percentage of predicted. It is possible that the z-score underestimates AL severity in patients older than 60 years of age with severe functional impairment.

  18. A reliable and cost effective approach for radiographic monitoring in nutritional rickets

    PubMed Central

    Gupta, V; Sharma, V; Sinha, B; Samanta, S

    2014-01-01

    Objective: Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. Methods: 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg−1) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Results: Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Conclusion: Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. Advances in knowledge: The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution. PMID:24593231

  19. Qualitative and quantitative assessment of degeneration of cervical intervertebral discs and facet joints.

    PubMed

    Walraevens, Joris; Liu, Baoge; Meersschaert, Joke; Demaerel, Philippe; Delye, Hans; Depreitere, Bart; Vander Sloten, Jos; Goffin, Jan

    2009-03-01

    Degeneration of intervertebral discs and facet joints is one of the most frequently encountered spinal disorders. In order to describe and quantify degeneration and evaluate a possible relationship between degeneration and biomechanical parameters, e.g., the intervertebral range of motion and intradiscal pressure, a scoring system for degeneration is mandatory. However, few scoring systems for the assessment of degeneration of the cervical spine exist. Therefore, two separate objective scoring systems to qualitatively and quantitatively assess the degree of cervical intervertebral disc and facet joint degeneration were developed and validated. The scoring system for cervical disc degeneration consists of three variables which are individually scored on neutral lateral radiographs: "height loss" (0-4 points), "anterior osteophytes" (0-3 points) and "endplate sclerosis" (0-2 points). The scoring system for facet joint degeneration consists of four variables which are individually scored on neutral computed tomography scans: "hypertrophy" (0-2 points), "osteophytes" (0-1 point), "irregularity" on the articular surface (0-1 point) and "joint space narrowing" (0-1 point). Each variable contributes with varying importance to the overall degeneration score (max 9 points for the scoring system of cervical disc degeneration and max 5 points for facet joint degeneration). Degeneration of 20 discs and facet joints of 20 patients was blindly assessed by four raters: two neurosurgeons (one senior and one junior) and two radiologists (one senior and one junior), firstly based on first subjective impression and secondly using the scoring systems. Measurement errors and inter- and intra-rater agreement were determined. The measurement error of the scoring system for cervical disc degeneration was 11.1 versus 17.9% of the subjective impression results. This scoring system showed excellent intra-rater agreement (ICC = 0.86, 0.75-0.93) and excellent inter-rater agreement (ICC = 0.78, 0.64-0.88). Surgeons as well as radiologists and seniors as well as juniors obtained excellent inter- and intra-rater agreement. The measurement error of the scoring system for cervical facet joint degeneration was 20.1 versus 24.2% of the subjective impression results. This scoring system showed good intra-rater agreement (ICC = 0.71, 0.42-0.89) and fair inter-rater agreement (ICC = 0.49, 0.26-0.74). Both scoring systems fulfilled the criteria for recommendation proposed by Kettler and Wilke. Our scoring systems can be reliable and objective tools for assessing cervical disc and facet joint degeneration. Moreover, the scoring system of cervical disc degeneration was shown to be experience- and discipline-independent.

  20. An inflammation-based cumulative prognostic score system in patients with diffuse large B cell lymphoma in rituximab era.

    PubMed

    Sun, Feifei; Zhu, Jia; Lu, Suying; Zhen, Zijun; Wang, Juan; Huang, Junting; Ding, Zonghui; Zeng, Musheng; Sun, Xiaofei

    2018-01-02

    Systemic inflammatory parameters are associated with poor outcomes in malignant patients. Several inflammation-based cumulative prognostic score systems were established for various solid tumors. However, there is few inflammation based cumulative prognostic score system for patients with diffuse large B cell lymphoma (DLBCL). We retrospectively reviewed 564 adult DLBCL patients who had received rituximab, cyclophosphamide, doxorubicin, vincristine and prednisolone (R-CHOP) therapy between Nov 1 2006 and Dec 30 2013 and assessed the prognostic significance of six systemic inflammatory parameters evaluated in previous studies by univariate and multivariate analysis:C-reactive protein(CRP), albumin levels, the lymphocyte-monocyte ratio (LMR), the neutrophil-lymphocyte ratio(NLR), the platelet-lymphocyte ratio(PLR)and fibrinogen levels. Multivariate analysis identified CRP, albumin levels and the LMR are three independent prognostic parameters for overall survival (OS). Based on these three factors, we constructed a novel inflammation-based cumulative prognostic score (ICPS) system. Four risk groups were formed: group ICPS = 0, ICPS = 1, ICPS = 2 and ICPS = 3. Advanced multivariate analysis indicated that the ICPS model is a prognostic score system independent of International Prognostic Index (IPI) for both progression-free survival (PFS) (p < 0.001) and OS (p < 0.001). The 3-year OS for patients with ICPS =0, ICPS =1, ICPS =2 and ICPS =3 were 95.6, 88.2, 76.0 and 62.2%, respectively (p < 0.001). The 3-year PFS for patients with ICPS = 0-1, ICPS = 2 and ICPS = 3 were 84.8, 71.6 and 54.5%, respectively (p < 0.001). The prognostic value of the ICPS model indicated that the degree of systemic inflammatory status was associated with clinical outcomes of patients with DLBCL in rituximab era. The ICPS model was shown to classify risk groups more accurately than any single inflammatory prognostic parameters. These findings may be useful for identifying candidates for further inflammation-related mechanism research or novel anti-inflammation target therapies.

  1. Understanding Elementary Astronomy by Making Drawing-Based Models

    NASA Astrophysics Data System (ADS)

    van Joolingen, W. R.; Aukes, Annika V. A.; Gijlers, H.; Bollen, L.

    2015-04-01

    Modeling is an important approach in the teaching and learning of science. In this study, we attempt to bring modeling within the reach of young children by creating the SimSketch modeling system, which is based on freehand drawings that can be turned into simulations. This system was used by 247 children (ages ranging from 7 to 15) to create a drawing-based model of the solar system. The results show that children in the target age group are capable of creating a drawing-based model of the solar system and can use it to show the situations in which eclipses occur. Structural equation modeling predicting post-test knowledge scores based on learners' pre-test knowledge scores, the quality of their drawings and motivational aspects yielded some evidence that such drawing contributes to learning. Consequences for using modeling with young children are considered.

  2. A Comparison of Systemic Inflammation-Based Prognostic Scores in Patients on Regular Hemodialysis

    PubMed Central

    Kato, Akihiko; Tsuji, Takayuki; Sakao, Yukitoshi; Ohashi, Naro; Yasuda, Hideo; Fujimoto, Taiki; Takita, Takako; Furuhashi, Mitsuyoshi; Kumagai, Hiromichi

    2013-01-01

    Background/Aims Systemic inflammation-based prognostic scores have prognostic power in patients with cancer, independently of tumor stage and site. Although inflammatory status is associated with mortality in hemodialysis (HD) patients, it remains to be determined as to whether these composite scores are useful in predicting clinical outcomes. Methods We calculated the 6 prognostic scores [Glasgow prognostic score (GPS), modified GPS (mGPS), neutrophil-lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), prognostic index (PI) and prognostic nutritional index (PNI), which have been established as a useful scoring system in cancer patients. We enrolled 339 patients on regular HD (age: 64 ± 13 years; time on HD: 129 ± 114 months; males/females = 253/85) and followed them for 42 months. The area under the receiver-operating characteristics curve was used to determine which scoring system was more predictive of mortality. Results Elevated GPS, mGPS, NLR, PLR, PI and PNI were all associated with total mortality, independent of covariates. If GPS was raised, mGPS, NLR, PLR and PI were also predictive of all-cause mortality and/or hospitalization. GPS and PNI were associated with poor nutritional status. Using overall mortality as an endpoint, the area under the curve (AUC) was significant for a GPS of 0.701 (95% CI: 0.637-0.765; p < 0.01) and for a PNI of 0.616 (95% CI: 0.553-0.768; p = 0.01). However, AUC for hypoalbuminemia (<3.5 g/dl) was comparable to that of GPS (0.695, 95% CI: 0.632-0.759; p < 0.01). Conclusion GPS, based on serum albumin and highly sensitive C-reactive protein, has the most prognostic power for mortality prediction among the prognostic scores in HD patients. However, as the determination of serum albumin reflects mortality similarly to GPS, other composite combinations are needed to provide additional clinical utility beyond that of albumin alone in HD patients. PMID:24403910

  3. A Scoring System to Determine Risk of Delayed Bleeding After Endoscopic Mucosal Resection of Large Colorectal Lesions.

    PubMed

    Albéniz, Eduardo; Fraile, María; Ibáñez, Berta; Alonso-Aguirre, Pedro; Martínez-Ares, David; Soto, Santiago; Gargallo, Carla Jerusalén; Ramos Zabala, Felipe; Álvarez, Marco Antonio; Rodríguez-Sánchez, Joaquín; Múgica, Fernando; Nogales, Óscar; Herreros de Tejada, Alberto; Redondo, Eduardo; Guarner-Argente, Carlos; Pin, Noel; León-Brito, Helena; Pardeiro, Remedios; López-Roses, Leopoldo; Rodríguez-Téllez, Manuel; Jiménez, Alejandra; Martínez-Alcalá, Felipe; García, Orlando; de la Peña, Joaquín; Ono, Akiko; Alberca de Las Parras, Fernando; Pellisé, María; Rivero, Liseth; Saperas, Esteban; Pérez-Roldán, Francisco; Pueyo Royo, Antonio; Eguaras Ros, Javier; Zúñiga Ripa, Alba; Concepción-Martín, Mar; Huelin-Álvarez, Patricia; Colán-Hernández, Juan; Cubiella, Joaquín; Remedios, David; Bessa I Caserras, Xavier; López-Viedma, Bartolomé; Cobian, Julyssa; González-Haba, Mariano; Santiago, José; Martínez-Cara, Juan Gabriel; Valdivielso, Eduardo

    2016-08-01

    After endoscopic mucosal resection (EMR) of colorectal lesions, delayed bleeding is the most common serious complication, but there are no guidelines for its prevention. We aimed to identify risk factors associated with delayed bleeding that required medical attention after discharge until day 15 and develop a scoring system to identify patients at risk. We performed a prospective study of 1214 consecutive patients with nonpedunculated colorectal lesions 20 mm or larger treated by EMR (n = 1255) at 23 hospitals in Spain, from February 2013 through February 2015. Patients were examined 15 days after the procedure, and medical data were collected. We used the data to create a delayed bleeding scoring system, and assigned a weight to each risk factor based on the β parameter from multivariate logistic regression analysis. Patients were classified as being at low, average, or high risk for delayed bleeding. Delayed bleeding occurred in 46 cases (3.7%, 95% confidence interval, 2.7%-4.9%). In multivariate analysis, factors associated with delayed bleeding included age ≥75 years (odds ratio [OR], 2.36; P < .01), American Society of Anesthesiologist classification scores of III or IV (OR, 1.90; P ≤ .05), aspirin use during EMR (OR, 3.16; P < .05), right-sided lesions (OR, 4.86; P < .01), lesion size ≥40 mm (OR, 1.91; P ≤ .05), and a mucosal gap not closed by hemoclips (OR, 3.63; P ≤ .01). We developed a risk scoring system based on these 6 variables that assigned patients to the low-risk (score, 0-3), average-risk (score, 4-7), or high-risk (score, 8-10) categories with a receiver operating characteristic curve of 0.77 (95% confidence interval, 0.70-0.83). In these groups, the probabilities of delayed bleeding were 0.6%, 5.5%, and 40%, respectively. The risk of delayed bleeding after EMR of large colorectal lesions is 3.7%. We developed a risk scoring system based on 6 factors that determined the risk for delayed bleeding (receiver operating characteristic curve, 0.77). The factors most strongly associated with delayed bleeding were right-sided lesions, aspirin use, and mucosal defects not closed by hemoclips. Patients considered to be high risk (score, 8-10) had a 40% probability of delayed bleeding. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  4. Zonal NePhRO scoring system: a superior renal tumor complexity classification model.

    PubMed

    Hakky, Tariq S; Baumgarten, Adam S; Allen, Bryan; Lin, Hui-Yi; Ercole, Cesar E; Sexton, Wade J; Spiess, Philippe E

    2014-02-01

    Since the advent of the first standardized renal tumor complexity system, many subsequent scoring systems have been introduced, many of which are complicated and can make it difficult to accurately measure data end points. In light of these limitations, we introduce the new zonal NePhRO scoring system. The zonal NePhRO score is based on 4 anatomical components that are assigned a score of 1, 2, or 3, and their sum is used to classify renal tumors. The zonal NePhRO scoring system is made up of the (Ne)arness to collecting system, (Ph)ysical location of the tumor in the kidney, (R)adius of the tumor, and (O)rganization of the tumor. In this retrospective study, we evaluated patients exhibiting clinical stage T1a or T1b who underwent open partial nephrectomy performed by 2 genitourinary surgeons. Each renal unit was assigned both a zonal NePhRO score and a RENAL (radius, exophytic/endophytic properties, nearness of tumor to the collecting system or sinus in millimeters, anterior/posterior, location relative to polar lines) score, and a blinded reviewer used the same preoperative imaging study to obtain both scores. Additional data points gathered included age, clamp time, complication rate, urine leak rate, intraoperative blood loss, and pathologic tumor size. One hundred sixty-six patients underwent open partial nephrectomy. There were 37 perioperative complications quantitated using the validated Clavien-Dindo system; their occurrence was predicted by the NePhRO score on both univariate and multivariate analyses (P = .0008). Clinical stage, intraoperative blood loss, and tumor diameter were all correlated with the zonal NePhRO score on univariate analysis only. The zonal NePhRO scoring system is a simpler tool that accurately predicts the surgical complexity of a renal lesion. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Error Rates in Measuring Teacher and School Performance Based on Student Test Score Gains. NCEE 2010-4004

    ERIC Educational Resources Information Center

    Schochet, Peter Z.; Chiang, Hanley S.

    2010-01-01

    This paper addresses likely error rates for measuring teacher and school performance in the upper elementary grades using value-added models applied to student test score gain data. Using realistic performance measurement system schemes based on hypothesis testing, we develop error rate formulas based on OLS and Empirical Bayes estimators.…

  6. A simple scoring system based on neutrophil count in sepsis patients.

    PubMed

    Ueda, Takahiro; Aoyama-Ishikawa, Michiko; Nakao, Atsunori; Yamada, Taihei; Usami, Makoto; Kotani, Joji

    2014-03-01

    The assessment of critically ill patients is often a challenge for clinicians. There are a number of scoring systems such as Acute Physiology and Chronic Health Evaluation II (APACHE II), Sequential Organ Failure Assessment (SOFA) and C-reactive protein test (CRP), which have been shown to correlate with outcome in a variety of Intensive Care Unit (ICU) patients. Therefore, use of repeated measures of these preexisting scores over time is a reasonable attempt to assess the severity of organ dysfunction and predict outcome in critically ill patients. Several reports suggest that the neutrophil is a useful marker of sepsis. However, since both a large number and a small number of neutrophils indicate a severe situation, neutrophil count is difficult to use to directly predict patients'. We proposed a novel scoring system identify predictive factors using a simple blood cell count that may be associated with mortality in ICU patients. Our novel scoring system (n-score) was calculated as follows: ranges of neutrophils of 0-4999 cells/mm(3) and 5000-9999 cells/mm(3) were defined as 3 and 1 points, respectively. When the neutrophil count was over 10,000 cells/mm(3), the score was calculated by dividing the number of cells by 10,000. Then, 1 or 2 points were added when patients were female or male, respectively. We hypothesize that n-score may be a simple and easy scoring system to estimate mortality of the patients with sepsis and severe sepsis/septic shock without requirement of special methods or special measuring equipment, and may be as reliable as the APACHE II score or SOFA score. The retrospective evaluation was conducted at the Department of Emergency, Disaster and Critical Care Medicine at the Hyogo College of Medicine. Seventy-seven patients who were admitted to the emergency center and diagnosed sepsis or severe sepsis/septic shock between June 2007 and December 2012 and gave informed consent were enrolled. The n-score was significantly higher in non-survivors of sepsis and severe sepsis/septic shock (p<0.01, t-test) than in survivors. The ROC curve showed a sensitivity of 61.5% and a specificity of 80.4% at an n-score of 3.8 points; the area under the curve was 0.736. In addition, n-score correlated with APACHE II score (p<0.01, R=0.378) and SOFA score (p<0.05, R=0.256) on admission. Based on these preliminary evaluations, we hypothesize that n-score may be a useful scoring system to detect risk of death in sepsis and severe sepsis/septic shock. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Anomalous diffusion in the evolution of soccer championship scores: Real data, mean-field analysis, and an agent-based model

    NASA Astrophysics Data System (ADS)

    da Silva, Roberto; Vainstein, Mendeli H.; Gonçalves, Sebastián; Paula, Felipe S. F.

    2013-08-01

    Statistics of soccer tournament scores based on the double round robin system of several countries are studied. Exploring the dynamics of team scoring during tournament seasons from recent years we find evidences of superdiffusion. A mean-field analysis results in a drift velocity equal to that of real data but in a different diffusion coefficient. Along with the analysis of real data we present the results of simulations of soccer tournaments obtained by an agent-based model which successfully describes the final scoring distribution [da Silva , Comput. Phys. Commun.CPHCBZ0010-465510.1016/j.cpc.2012.10.030 184, 661 (2013)]. Such model yields random walks of scores over time with the same anomalous diffusion as observed in real data.

  8. Qualitative Dimensions in Scoring the Rey Visual Memory Test of Malingering.

    ERIC Educational Resources Information Center

    Griffin, G. A. Elmer; And Others

    1996-01-01

    A new qualitative scoring system for the Rey Visual Memory Test was tested for its ability to distinguish between malingerers and nonmalingerers. The new system, based on the types of errors made, was able to distinguish between 53 psychiatrically disabled and 64 normal nonmalingerers, and between nonmalingerers and 91 possible malingerers. (SLD)

  9. Food variety and dietary diversity scores to understand the food-intake pattern among selected Malaysian households.

    PubMed

    Zainal Badari, Shamsul A; Arcot, Jayashree; Haron, Sharifah A; Paim, Laily; Sulaiman, Norhasmah; Masud, Jariah

    2012-01-01

    Food variety scores (FVS) and dietary diversity scores (DDS) were estimated based on foods consumed weekly by 285 Malaysian households using a food frequency questionnaire. The scoring system of FVS and DDS was based on a scale of 0-7 and 0-6 respectively. The mean household FVS and DDS was 164.1 ± 93 and 6 ± 0.4. The age of respondents (husbands or wives; p < .01), sex (p < .05), and household food expenditure (p < .01) had a significant influence on both FVS and DDS. The food-intake pattern of Malaysian households showed that their typical diets had high protein and energy-based foods.

  10. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 2: reliability and application to multiple joints of a standardised consensus-based scoring system

    PubMed Central

    Terslev, Lene; Naredo, Esperanza; Aegerter, Philippe; Wakefield, Richard J; Backhaus, Marina; Balint, Peter; Bruyn, George A W; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; Filippucci, Emilio

    2017-01-01

    Objectives To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms–Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. Methods A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. Results Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a ‘standardised’ scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8–0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41–0.92). Conclusion The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials. PMID:28948984

  11. Validation of the FAMACHA© system in South American camelids.

    PubMed

    Storey, Bobby E; Williamson, Lisa H; Howell, Sue B; Terrill, Thomas H; Berghaus, Roy; Vidyashankar, Anand N; Kaplan, Ray M

    2017-08-30

    Haemonchus contortus resistant to multiple anthelmintics threaten the viability of the small ruminant industry in areas where this parasite is prevalent. In response to this situation, the FAMACHA© system was developed and validated for use with small ruminants as a way to detect clinical anemia associated with haemonchosis. Given that H. contortus and multiple anthelmintic resistance is a similar problem in camelids, the FAMACHA© system might also provide the same benefits. To address this need, a validation study of the FAMACHA© system was conducted on 21 alpaca and llama farms over a 2-year period. H. contortus was the predominant nematode parasite on 17 of the 21 farms (10 alpaca and 7 llama farms) enrolled in the study, based on fecal culture results. The FAMACHA© card was used to score the color of the lower palpebral (lower eye lid) conjunctiva on a 1-5 scale. Packed cell volume (PCV) values were measured and compared to FAMACHA© scores using FAMACHA© score cutoffs of ≥3 or ≥4 and with anemia defined as a PCV ≤15%, ≤17%, or≤20%. PCV was significantly associated with FAMACHA© score, fecal egg count (FEC), and body condition score (BCS), regardless of the FAMACHA© cutoff score or the PCV% chosen to define clinical anemia (p<0.01 in all cases). The use of FAMACHA© scores ≥3 and PCV ≥ 15% indicating anemia provided the best sensitivity (96.4% vs 92.9% for FAMACHA© ≥4), whereas FAMACHA scores ≥ 4 and PCV ≤20% provided the best specificity (94.2% vs 69.1% for FAMACHA© ≥3). The data from this study support the FAMACHA© system as a useful tool for detecting clinical anemia in camelids suffering from haemonchosis. Parameters for making treatment decisions based on FAMACHA© score in camelids should mirror those established for small ruminants. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Does tooth wear status predict ongoing sleep bruxism in 30-year-old Japanese subjects?

    PubMed

    Baba, Kazuyoshi; Haketa, Tadasu; Clark, Glenn T; Ohyama, Takashi

    2004-01-01

    This study investigated whether tooth wear status can predict bruxism level. Sixteen Japanese subjects (eight bruxers and eight age- and gender-matched controls; mean age 30 years) participated in this study. From dental casts of these subjects, the tooth wear was scored by Murphy's method. Bruxism level in these subjects was also recorded for 5 consecutive nights in the subject's home environment using a force-based bruxism detecting system. The relationship between the tooth wear score and bruxism data was evaluated statistically. Correlation analysis between the Murphy's scores of maxillary and mandibular dental arch and bruxism event duration score revealed no significant relationship between tooth wear and current bruxism. Tooth wear status is not predictive of ongoing bruxism level as measured by the force-based bruxism detection system in 30-year-old Japanese subjects.

  13. Imaging diagnostics in ovarian cancer: magnetic resonance imaging and a scoring system guiding choice of primary treatment.

    PubMed

    Kasper, Sigrid M; Dueholm, Margit; Marinovskij, Edvard; Blaakær, Jan

    2017-03-01

    To analyze the ability of magnetic resonance imaging (MRI) and systematic evaluation at surgery to predict optimal cytoreduction in primary advanced ovarian cancer and to develop a preoperative scoring system for cancer staging. Preoperative MRI and standard laparotomy were performed in 99 women with either ovarian or primary peritoneal cancer. Using univariate and multivariate logistic regression analysis of a systematic description of the tumor in nine abdominal compartments obtained by MRI and during surgery plus clinical parameters, a scoring system was designed that predicted non-optimal cytoreduction. Non-optimal cytoreduction at operation was predicted by the following: (A) presence of comorbidities group 3 or 4 (ASA); (B) tumor presence in multiple numbers of different compartments, and (C) numbers of specified sites of organ involvement. The score includes: number of compartments involved (1-9 points), >1 subdiaphragmal location with presence of tumor (1 point); deep organ involvement of liver (1 point), porta hepatis (1 point), spleen (1 point), mesentery/vessel (1 point), cecum/ileocecal (1 point), rectum/vessels (1 point): ASA groups 3 and 4 (2 points). Use of the scoring system based on operative findings gave an area under the curve (AUC) of 91% (85-98%) for patients in whom optimal cytoreduction could not be achieved. The score AUC obtained by MRI was 84% (76-92%), and 43% of non-optimal cytoreduction patients were identified, with only 8% of potentially operable patients being falsely evaluated as suitable for non-optimal cytoreduction at the most optimal cut-off value. Tumor in individual locations did not predict operability. This systematic scoring system based on operative findings and MRI may predict non-optimal cytoreduction. MRI is able to assess ovarian cancer with peritoneal carcinomatosis with satisfactory concordance with laparotomic findings. This scoring system could be useful as a clinical guideline and should be evaluated and developed further in larger studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Impact on house staff evaluation scores when changing from a Dreyfus- to a Milestone-based evaluation model: one internal medicine residency program's findings.

    PubMed

    Friedman, Karen A; Balwan, Sandy; Cacace, Frank; Katona, Kyle; Sunday, Suzanne; Chaudhry, Saima

    2014-01-01

    As graduate medical education (GME) moves into the Next Accreditation System (NAS), programs must take a critical look at their current models of evaluation and assess how well they align with reporting outcomes. Our objective was to assess the impact on house staff evaluation scores when transitioning from a Dreyfus-based model of evaluation to a Milestone-based model of evaluation. Milestones are a key component of the NAS. We analyzed all end of rotation evaluations of house staff completed by faculty for academic years 2010-2011 (pre-Dreyfus model) and 2011-2012 (post-Milestone model) in one large university-based internal medicine residency training program. Main measures included change in PGY-level average score; slope, range, and separation of average scores across all six Accreditation Council for Graduate Medical Education (ACGME) competencies. Transitioning from a Dreyfus-based model to a Milestone-based model resulted in a larger separation in the scores between our three post-graduate year classes, a steeper progression of scores in the PGY-1 class, a wider use of the 5-point scale on our global end of rotation evaluation form, and a downward shift in the PGY-1 scores and an upward shift in the PGY-3 scores. For faculty trained in both models of assessment, the Milestone-based model had greater discriminatory ability as evidenced by the larger separation in the scores for all the classes, in particular the PGY-1 class.

  15. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: A prospective study of 39 cases with pre and post treatment assessment.

    PubMed

    Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand

    2013-04-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value < 0.001. The scintigraphic scoring system had a sensitivity of 93.9% in assessing treatment response to domperidone, specificity of 83.3% i.e., 83.3% of children with no decline in scintigraphic scores show no clinical response to Domperidone. The scintigraphic scoring system had a positive predictive value of 96.9% and a negative predictive value of 71.4%. GERS with its quantitative parameters is a good investigation for assessing the severity of reflux and also for following children post-treatment.

  16. Personalized Risk Scoring for Critical Care Prognosis Using Mixtures of Gaussian Processes.

    PubMed

    Alaa, Ahmed M; Yoon, Jinsung; Hu, Scott; van der Schaar, Mihaela

    2018-01-01

    In this paper, we develop a personalized real-time risk scoring algorithm that provides timely and granular assessments for the clinical acuity of ward patients based on their (temporal) lab tests and vital signs; the proposed risk scoring system ensures timely intensive care unit admissions for clinically deteriorating patients. The risk scoring system is based on the idea of sequential hypothesis testing under an uncertain time horizon. The system learns a set of latent patient subtypes from the offline electronic health record data, and trains a mixture of Gaussian Process experts, where each expert models the physiological data streams associated with a specific patient subtype. Transfer learning techniques are used to learn the relationship between a patient's latent subtype and her static admission information (e.g., age, gender, transfer status, ICD-9 codes, etc). Experiments conducted on data from a heterogeneous cohort of 6321 patients admitted to Ronald Reagan UCLA medical center show that our score significantly outperforms the currently deployed risk scores, such as the Rothman index, MEWS, APACHE, and SOFA scores, in terms of timeliness, true positive rate, and positive predictive value. Our results reflect the importance of adopting the concepts of personalized medicine in critical care settings; significant accuracy and timeliness gains can be achieved by accounting for the patients' heterogeneity. The proposed risk scoring methodology can confer huge clinical and social benefits on a massive number of critically ill inpatients who exhibit adverse outcomes including, but not limited to, cardiac arrests, respiratory arrests, and septic shocks.

  17. Evaluation of the effects of implementing an electronic early warning score system: protocol for a stepped wedge study.

    PubMed

    Bonnici, Timothy; Gerry, Stephen; Wong, David; Knight, Julia; Watkinson, Peter

    2016-02-09

    An Early Warning Score is a clinical risk score based upon vital signs intended to aid recognition of patients in need of urgent medical attention. The use of an escalation of care policy based upon an Early Warning Score is mandated as the standard of practice in British hospitals. Electronic systems for recording vital sign observations and Early Warning Score calculation offer theoretical benefits over paper-based systems. However, the evidence for their clinical benefit is limited. Previous studies have shown inconsistent results. The majority have employed a "before and after" study design, which may be strongly confounded by simultaneously occurring events. This study aims to examine how the implementation of an electronic early warning score system, System for Notification and Documentation (SEND), affects the recognition of clinical deterioration occurring in hospitalised adult patients. This study is a non-randomised stepped wedge evaluation carried out across the four hospitals of the Oxford University Hospitals NHS Trust, comparing charting on paper and charting using SEND. We assume that more frequent monitoring of acutely ill patients is associated with better recognition of patient deterioration. The primary outcome measure is the time between a patient's first observations set with an Early Warning Score above the alerting threshold and their subsequent set of observations. Secondary outcome measures are in-hospital mortality, cardiac arrest and Intensive Care admission rates, hospital length of stay and system usability measured using the System Usability Scale. We will also measure Intensive Care length of stay, Intensive Care mortality, Acute Physiology and Chronic Health Evaluation (APACHE) II acute physiology score on admission, to examine whether the introduction of SEND has any effect on Intensive Care-related outcomes. The development of this protocol has been informed by guidance from the Agency for Healthcare Research and Quality (AHRQ) Health Information Technology Evaluation Toolkit and Delone and McLeans's Model of Information System Success. Our chosen trial design, a stepped wedge study, is well suited to the study of a phased roll out. The choice of primary endpoint is challenging. We have selected the time from the first triggering observation set to the subsequent observation set. This has the benefit of being easy to measure on both paper and electronic charting and having a straightforward interpretation. We have collected qualitative measures of system quality via a user questionnaire and organisational descriptors to help readers understand the context in which SEND has been implemented.

  18. Evaluation of precipitation forecasts from 3D-Var and hybrid GSI-based system during Indian summer monsoon 2015

    NASA Astrophysics Data System (ADS)

    Singh, Sanjeev Kumar; Prasad, V. S.

    2018-02-01

    This paper presents a systematic investigation of medium-range rainfall forecasts from two versions of the National Centre for Medium Range Weather Forecasting (NCMRWF)-Global Forecast System based on three-dimensional variational (3D-Var) and hybrid analysis system namely, NGFS and HNGFS, respectively, during Indian summer monsoon (June-September) 2015. The NGFS uses gridpoint statistical interpolation (GSI) 3D-Var data assimilation system, whereas HNGFS uses hybrid 3D ensemble-variational scheme. The analysis includes the evaluation of rainfall fields and comparisons of rainfall using statistical score such as mean precipitation, bias, correlation coefficient, root mean square error and forecast improvement factor. In addition to these, categorical scores like Peirce skill score and bias score are also computed to describe particular aspects of forecasts performance. The comparison results of mean precipitation reveal that both the versions of model produced similar large-scale feature of Indian summer monsoon rainfall for day-1 through day-5 forecasts. The inclusion of fully flow-dependent background error covariance significantly improved the wet biases in HNGFS over the Indian Ocean. The forecast improvement factor and Peirce skill score in the HNGFS have also found better than NGFS for day-1 through day-5 forecasts.

  19. How education systems shape cross-national ethnic inequality in math competence scores: Moving beyond mean differences.

    PubMed

    Spörlein, Christoph; Schlueter, Elmar

    2018-01-01

    Here we examine a conceptualization of immigrant assimilation that is based on the more general notion that distributional differences erode across generations. We explore this idea by reinvestigating the efficiency-equality trade-off hypothesis, which posits that stratified education systems educate students more efficiently at the cost of increasing inequality in overall levels of competence. In the context of ethnic inequality in math achievement, this study explores the extent to which an education system's characteristics are associated with ethnic inequality in terms of both the group means and group variances in achievement. Based on data from the 2012 PISA and mixed-effect location scale models, our analyses revealed two effects: on average, minority students had lower math scores than majority students, and minority students' scores were more concentrated at the lower end of the distribution. However, the ethnic inequality in the distribution of scores declined across generations. We did not find compelling evidence that stratified education systems increase mean differences in competency between minority and majority students. However, our analyses revealed that in countries with early educational tracking, minority students' math scores tended to cluster at the lower end of the distribution, regardless of compositional and school differences between majority and minority students.

  20. Lameness scoring system for dairy cows using force plates and artificial intelligence.

    PubMed

    Ghotoorlar, S Mokaram; Ghamsari, S Mehdi; Nowrouzian, I; Ghotoorlar, S Mokaram; Ghidary, S Shiry

    2012-02-04

    Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5.

  1. The Harrington-O'Shea Career Decision-Making System (CDM) and the Kaufman Adolescent and Adult Intelligence Test (KAIT): Relationship of Interest Scale Scores to Fluid and Crystallized IQs at Ages 12 to 22 Years.

    ERIC Educational Resources Information Center

    McLean, James E.; Kaufman, Alan S.

    1995-01-01

    The six Holland-based Interest Scale scores yielded by the Harrington-O'Shea Career Decision-Making System (CDM) (T. Harrington and A. O'Shea, 1982) were related to sex, race, and performance on the Kaufman Adolescent and Adult Intelligence Test for 254 adolescents and young adults. CDM scores did not relate to most of the variables studied, and…

  2. Design and pilot evaluation of a system to develop computer-based site-specific practice guidelines from decision models.

    PubMed

    Sanders, G D; Nease, R F; Owens, D K

    2000-01-01

    Local tailoring of clinical practice guidelines (CPGs) requires experts in medicine and evidence synthesis unavailable in many practice settings. The authors' computer-based system enables developers and users to create, disseminate, and tailor CPGs, using normative decision models (DMs). ALCHEMIST, a web-based system, analyzes a DM, creates a CPG in the form of an annotated algorithm, and displays for the guideline user the optimal strategy. ALCHEMIST'S interface enables remote users to tailor the guideline by changing underlying input variables and observing the new annotated algorithm that is developed automatically. In a pilot evaluation of the system, a DM was used to evaluate strategies for staging non-small-cell lung cancer. Subjects (n = 15) compared the automatically created CPG with published guidelines for this staging and critiqued both using a previously developed instrument to rate the CPGs' usability, accountability, and accuracy on a scale of 0 (worst) to 2 (best), with higher scores reflecting higher quality. The mean overall score for the ALCHEMIST CPG was 1.502, compared with the published-CPG score of 0.987 (p = 0.002). The ALCHEMIST CPG scores for usability, accountability, and accuracy were 1.683, 1.393, and 1.430, respectively; the published CPG scores were 1.192, 0.941, and 0.830 (each comparison p < 0.05). On a scale of 1 (worst) to 5 (best), users' mean ratings of ALCHEMIST'S ease of use, usefulness of content, and presentation format were 4.76, 3.98, and 4.64, respectively. The results demonstrate the feasibility of a web-based system that automatically analyzes a DM and creates a CPG as an annotated algorithm, enabling remote users to develop site-specific CPGs. In the pilot evaluation, the ALCHEMIST guidelines met established criteria for quality and compared favorably with national CPGs. The high usability and usefulness ratings suggest that such systems can be a good tool for guideline development.

  3. The S.A.C.S. (Satisfaction-Anatomy-Continence-Safety) score for evaluating pelvic organ prolapse surgery: a proposal for an outcome-based scoring system.

    PubMed

    Mearini, Luigi; Zucchi, Alessandro; Nunzi, Elisabetta; Di Biase, Manuel; Bini, Vittorio; Costantini, Elisabetta

    2015-07-01

    To date, there is no overall consensus on the definition of cure after surgery for pelvic organ prolapse (POP). The aim of the study was to design and test the scoring system S.A.C.S. (Satisfaction-Anatomy-Continence-Safety) to assess and compare the outcomes of POP repair. A total of 233 women underwent open sacrocolpopexy. The S.A.C.S. outcome scoring system was scheduled at 24 months of follow-up, and each component was detected according to: Satisfaction by mean of Patient Global Improvement Inventory scale, Anatomy by mean of POP Quantification system and bulge symptom, Continence by mean of pad use, and Safety by mean of the Clavien-Dindo classification of surgical complications. Each component produced a binary nominal categorical variable (1 or 0), with a total score of 4 representing cure. As a comparative tool, patients answered a simple yes/no question: "If you had to undergo surgery all over again, would you still do it?". The degree of concordance was estimated using Cohen's Kappa test. According to the S.A.C.S. scoring system, only 160 patients (68.6 %) reached the maximum score of cure. Sensitivity of the S.A.C.S. score was 74.1 %, specificity was 90 %, total diagnostic capacity was 75.5 %. The S.A.C.S. score internal consistency was good; the k-coefficient was higher for the satisfaction component of the score (k = 0.560). This study proposes an original, simple post-operative scoring system integrating satisfaction, anatomy, continence, and safety reports for patients undergoing surgery for POP, providing a complete, although perfectible, method to accurately report outcomes in all clinical scenarios.

  4. The Warwick system of prospective workload allocation in cellular pathology—an aid to subspecialisation: a comparison with the Royal College of Pathologists' system

    PubMed Central

    Carr, R A; Sanders, D S A; Stores, O P; Smew, F A; Parkes, M E; Ross‐Gilbertson, V; Chachlani, N; Simon, J

    2006-01-01

    Background Guidelines on staffing and workload for histopathology and cytopathology departments was published by the Royal College of Pathologists (RCPath) in July 2003. In this document, a system is provided whereby the workload of a cellular pathology department and individual pathologists can be assessed with a scoring system based on specialty and complexity of the specimens. A similar, but simplified, system of scoring specimens by specialty was developed in the Warwick District General Hospital. The system was based on the specimen type and suggested clinical diagnosis, so that specimens could be allocated prospectively by the laboratory technical staff to even out workload and support subspecialisation in a department staffed by 4.6 whole‐time equivalent consultant pathologists. Methods The pathologists were asked to indicate their reporting preferences to determine specialist reporting teams. The workload was allocated according to the “prospective” Warwick system (based on specimen type and suggested clinical diagnosis, not affected by final diagnosis or individual pathologist variation in reference to numbers of blocks, sections and special stains examined) for October 2003. The cumulative Warwick score was compared with the “retrospective” RCPath scoring system for each pathologist and between specialties. Four pathologists recorded their time for cut‐up and reporting for the month audited. Results The equitable distribution of work between pathologists was ensured by the Warwick allocation and workload system, hence facilitating specialist reporting. Less variation was observed in points reported per hour by the Warwick system (6.3 (range 5.5–6.9)) than by the RCPath system (11.5 (range 9.3–15)). Conclusions The RCPath system of scoring is inherently complex, is applied retrospectively and is not consistent across subspecialities. The Warwick system is simpler, prospective and can be run by technical staff; it facilitates even workload distribution throughout the day. Subspecialisation within a small‐sized or medium‐sized department with fair distribution of work between pathologists is also allowed for by this system. Reporting times among pathologists were shown by time and motion studies to be more consistent with Warwick points per hour than with RCPath points per hour. PMID:16524963

  5. Applicability of the Classroom Assessment Scoring System in Chinese Preschools Based on Psychometric Evidence

    ERIC Educational Resources Information Center

    Hu, Bi Ying; Fan, Xitao; Gu, Chuanhua; Yang, Ning

    2016-01-01

    Research Findings: This study examined the applicability of the Classroom Assessment Scoring System (CLASS) Pre-K (Pianta, La Paro, & Hamre, 2008) and its underpinning framework of teaching through interactions in typical Chinese kindergarten classrooms. A sample of 180 kindergarten classrooms in China was selected, and the CLASS was used to…

  6. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  7. Systemic Inflammation-Based Biomarkers and Survival in HIV-Positive Subject With Solid Cancer in an Italian Multicenter Study.

    PubMed

    Raffetti, Elena; Donato, Francesco; Pezzoli, Chiara; Digiambenedetto, Simona; Bandera, Alessandra; Di Pietro, Massimo; Di Filippo, Elisa; Maggiolo, Franco; Sighinolfi, Laura; Fornabaio, Chiara; Castelnuovo, Filippo; Ladisa, Nicoletta; Castelli, Francesco; Quiros Roldan, Eugenia

    2015-08-15

    Recently, some systemic inflammation-based biomarkers have been demonstrated useful for predicting risk of death in patients with solid cancer independently of tumor characteristics. This study aimed to investigate the prognostic role of systemic inflammation-based biomarkers in HIV-infected patients with solid tumors and to propose a risk score for mortality in these subjects. Clinical and pathological data on solid AIDS-defining cancer (ADC) and non-AIDS-defining cancer (NADC), diagnosed between 1998 and 2012 in an Italian cohort, were analyzed. To evaluate the prognostic role of systemic inflammation- and nutrition-based markers, univariate and multivariable Cox regression models were applied. To compute the risk score equation, the patients were randomly assigned to a derivation and a validation sample. A total of 573 patients (76.3% males) with a mean age of 46.2 years (SD = 10.3) were enrolled. 178 patients died during a median of 3.2 years of follow-up. For solid NADCs, elevated Glasgow Prognostic Score, modified Glasgow Prognostic Score, neutrophil/lymphocyte ratio, platelet/lymphocyte ratio, and Prognostic Nutritional Index were independently associated with risk of death; for solid ADCs, none of these markers was associated with risk of death. For solid NADCs, we computed a mortality risk score on the basis of age at cancer diagnosis, intravenous drug use, and Prognostic Nutritional Index. The areas under the receiver operating characteristic curve were 0.67 (95% confidence interval: 0.58 to 0.75) in the derivation sample and 0.66 (95% confidence interval: 0.54 to 0.79) in the validation sample. Inflammatory biomarkers were associated with risk of death in HIV-infected patients with solid NADCs but not with ADCs.

  8. Associations between nutritional quality of meals and snacks assessed by the Food Standards Agency nutrient profiling system and overall diet quality and adiposity measures in British children and adolescents.

    PubMed

    Murakami, Kentaro

    2018-05-01

    This cross-sectional study examined how the nutritional quality of meals and snacks was associated with overall diet quality and adiposity measures. Based on 7-d weighed dietary record data, all eating occasions were divided into meals or snacks based on time (meals: 06:00-09:00 h, 12:00-14:00 h, and 17:00-20:00 h; snacks: others) or contribution to energy intake (meals: ≥15%; snacks: <15%) in British children aged 4-10 (n = 808) and adolescents aged 11-18 (n = 809). The nutritional quality of meals and snacks was assessed as the arithmetical energy intake-weighted means of the Food Standards Agency (FSA) nutrient profiling system score of each food and beverage consumed, based on the contents of energy, saturated fatty acid, total sugar, sodium, fruits/vegetables/nuts, dietary fiber, and protein. Regardless of the definition of meals and snacks, higher FSA score (lower nutritional quality) of meals was inversely associated with overall diet quality assessed by the Mediterranean diet score in both children and adolescents (P <0.0001), whereas the inverse associations for the FSA score of snacks did not reach statistical significance. The FSA score of meals based on time was inversely associated with body mass index z-score only in children, whereas that of snacks based on time showed a positive association. Lower nutritional quality of meals, but not snacks, assessed by the FSA score was associated with lower overall diet quality, whereas no consistent associations were observed with regard to adiposity measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Lameness Detection in Dairy Cows: Part 1. How to Distinguish between Non-Lame and Lame Cows Based on Differences in Locomotion or Behavior

    PubMed Central

    Van Nuffel, Annelies; Zwertvaegher, Ingrid; Pluym, Liesbet; Van Weyenberg, Stephanie; Thorup, Vivi M.; Pastell, Matti; Sonck, Bart; Saeys, Wouter

    2015-01-01

    Simple Summary Scoring cattle for lameness based on changes in locomotion or behavior is essential for farmers to find and treat their lame animals. This review discusses the normal locomotion of cows in order to define abnormal locomotion due to lameness. It furthermore provides an overview of various relevant visual locomotion scoring systems that are currently being used as well as practical considerations when assessing lameness on a commercial farm. Abstract Due to its detrimental effect on cow welfare, health and production, lameness in dairy cows has received quite a lot of attention in the last few decades—not only in terms of prevention and treatment of lameness but also in terms of detection, as early treatment might decrease the number of severely lame cows in the herds as well as decrease the direct and indirect costs associated with lameness cases. Generally, lame cows are detected by the herdsman, hoof trimmer or veterinarian based on abnormal locomotion, abnormal behavior or the presence of hoof lesions during routine trimming. In the scientific literature, several guidelines are proposed to detect lame cows based on visual interpretation of the locomotion of individual cows (i.e., locomotion scoring systems). Researchers and the industry have focused on automating such observations to support the farmer in finding the lame cows in their herds, but until now, such automated systems have rarely been used in commercial herds. This review starts with the description of normal locomotion of cows in order to define ‘abnormal’ locomotion caused by lameness. Cow locomotion (gait and posture) and behavioral features that change when a cow becomes lame are described and linked to the existing visual scoring systems. In addition, the lack of information of normal cow gait and a clear description of ‘abnormal’ gait are discussed. Finally, the different set-ups used during locomotion scoring and their influence on the resulting locomotion scores are evaluated. PMID:26479389

  10. Weighted hybrid technique for recommender system

    NASA Astrophysics Data System (ADS)

    Suriati, S.; Dwiastuti, Meisyarah; Tulus, T.

    2017-12-01

    Recommender system becomes very popular and has important role in an information system or webpages nowadays. A recommender system tries to make a prediction of which item a user may like based on his activity on the system. There are some familiar techniques to build a recommender system, such as content-based filtering and collaborative filtering. Content-based filtering does not involve opinions from human to make the prediction, while collaborative filtering does, so collaborative filtering can predict more accurately. However, collaborative filtering cannot give prediction to items which have never been rated by any user. In order to cover the drawbacks of each approach with the advantages of other approach, both approaches can be combined with an approach known as hybrid technique. Hybrid technique used in this work is weighted technique in which the prediction score is combination linear of scores gained by techniques that are combined.The purpose of this work is to show how an approach of weighted hybrid technique combining content-based filtering and item-based collaborative filtering can work in a movie recommender system and to show the performance comparison when both approachare combined and when each approach works alone. There are three experiments done in this work, combining both techniques with different parameters. The result shows that the weighted hybrid technique that is done in this work does not really boost the performance up, but it helps to give prediction score for unrated movies that are impossible to be recommended by only using collaborative filtering.

  11. Clinical risk scoring system for predicting extended-spectrum β-lactamase-producing Escherichia coli infection in hospitalized patients.

    PubMed

    Kengkla, K; Charoensuk, N; Chaichana, M; Puangjan, S; Rattanapornsompong, T; Choorassamee, J; Wilairat, P; Saokaew, S

    2016-05-01

    Extended spectrum β-lactamase-producing Escherichia coli (ESBL-EC) has important implications for infection control and empiric antibiotic prescribing. This study aims to develop a risk scoring system for predicting ESBL-EC infection based on local epidemiology. The study retrospectively collected eligible patients with a positive culture for E. coli during 2011 to 2014. The risk scoring system was developed using variables independently associated with ESBL-EC infection through logistic regression-based prediction. Area under the receiver-operator characteristic curve (AuROC) was determined to confirm the prediction power of the model. Predictors for ESBL-EC infection were male gender [odds ratio (OR): 1.53], age ≥55 years (OR: 1.50), healthcare-associated infection (OR: 3.21), hospital-acquired infection (OR: 2.28), sepsis (OR: 1.79), prolonged hospitalization (OR: 1.88), history of ESBL infection within one year (OR: 7.88), prior use of broad-spectrum cephalosporins within three months (OR: 12.92), and prior use of other antibiotics within three months (OR: 2.14). Points scored ranged from 0 to 47, and were divided into three groups based on diagnostic performance parameters: low risk (score: 0-8; 44.57%), moderate risk (score: 9-11; 21.85%) and high risk (score: ≥12; 33.58%). The model displayed moderate power of prediction (AuROC: 0.773; 95% confidence interval: 0.742-0.805) and good calibration (Hosmer-Lemeshow χ(2) = 13.29; P = 0.065). This tool may optimize the prescribing of empirical antibiotic therapy, minimize time to identify patients, and prevent spreading of ESBL-EC. Prior to adoption into routine clinical practice, further validation study of the tool is needed. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Analysis of Four Scoring Systems for the Prognosis of Patients with Metastasis of the Vertebral Column.

    PubMed

    Pollner, Péter; Horváth, Anna; Mezei, Tamás; Banczerowski, Péter; Czigléczki, Gábor

    2018-04-01

    Metastatic spinal diseases are common health problems and there is no consensus on the appropriate treatment of metastases in several conditions. Using clinical measures (e.g., survival time and functional status), prognosis prediction systems advise on the appropriate interventions. The aim of this article is to assess and compare 4 widely used scoring systems (revised Tokuhashi, Tomita, van der Linden, and modified Bauer scores) on a single-center cohort. A retrospective study was designed of 329 patients who were subjected to surgery because of metastatic spinal diseases. Subpopulations according to the classifications of the 4 scoring systems were identified. The overall survival was calculated with the Kaplan-Meier formula. The difference between the survival curves of subpopulations was analyzed with log-rank tests. The consistency rates for the 4 scoring systems are calculated as well. The follow-up period was 8 years. The median survival time was 222 days. The overall survival of prognostic categories in 3 scoring systems was significantly different from each other, but we found no differences between the categories of the van der Linden system. In this cohort, the revised Tokuhashi system gave the best approximation for survival, with a mean predictive capability 60.5%. The evaluation of 4 standard scoring systems showed that 3 were self-consistent, although none of systems was able to predict the survival in our cohort. Based on the predictive capability, the revised Tokuhashi system may provide the best predictions with careful examination of individual cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Predictive value of seven preoperative prognostic scoring systems for spinal metastases.

    PubMed

    Leithner, Andreas; Radl, Roman; Gruber, Gerald; Hochegger, Markus; Leithner, Katharina; Welkerling, Heike; Rehak, Peter; Windhager, Reinhard

    2008-11-01

    Predicting prognosis is the key factor in selecting the proper treatment modality for patients with spinal metastases. Therefore, various assessment systems have been designed in order to provide a basis for deciding the course of treatment. Such systems have been proposed by Tokuhashi, Sioutos, Tomita, Van der Linden, and Bauer. The scores differ greatly in the kind of parameters assessed. The aim of this study was to evaluate the prognostic value of each score. Eight parameters were assessed for 69 patients (37 male, 32 female): location, general condition, number of extraspinal bone metastases, number of spinal metastases, visceral metastases, primary tumour, severity of spinal cord palsy, and pathological fracture. Scores according to Tokuhashi (original and revised), Sioutos, Tomita, Van der Linden, and Bauer were assessed as well as a modified Bauer score without scoring for pathologic fracture. Nineteen patients were still alive as of September 2006 with a minimum follow-up of 12 months. All other patients died after a mean period of 17 months after operation. The mean overall survival period was only 3 months for lung cancer, followed by prostate (7 months), kidney (23 months), breast (35 months), and multiple myeloma (51 months). At univariate survival analysis, primary tumour and visceral metastases were significant parameters, while Karnofsky score was only significant in the group including myeloma patients. In multivariate analysis of all seven parameters assessed, primary tumour and visceral metastases were the only significant parameters. Of all seven scoring systems, the original Bauer score and a Bauer score without scoring for pathologic fracture had the best association with survival (P < 0.001). The data of the present study emphasize that the original Bauer score and a modified Bauer score without scoring for pathologic fracture seem to be practicable and highly predictive preoperative scoring systems for patients with spinal metastases. However, decision for or against surgery should never be based alone on a prognostic score but should take symptoms like pain or neurological compromise into account.

  14. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    PubMed

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p < 0.001). In receiver operating characteristic analysis, our category system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p < 0.001) and total GFR decline (area-under-the-curve = 0.796, p < 0.001), and split GFR decline (area-under-the-curve = 0.841, p < 0.001). Peritumoral artery characteristics were independent predictors of renal function outcome after laparoscopic partial nephrectomy.

  15. Web-based training and interrater reliability testing for scoring the Hamilton Depression Rating Scale.

    PubMed

    Rosen, Jules; Mulsant, Benoit H; Marino, Patricia; Groening, Christopher; Young, Robert C; Fox, Debra

    2008-10-30

    Despite the importance of establishing shared scoring conventions and assessing interrater reliability in clinical trials in psychiatry, these elements are often overlooked. Obstacles to rater training and reliability testing include logistic difficulties in providing live training sessions, or mailing videotapes of patients to multiple sites and collecting the data for analysis. To address some of these obstacles, a web-based interactive video system was developed. It uses actors of diverse ages, gender and race to train raters how to score the Hamilton Depression Rating Scale and to assess interrater reliability. This system was tested with a group of experienced and novice raters within a single site. It was subsequently used to train raters of a federally funded multi-center clinical trial on scoring conventions and to test their interrater reliability. The advantages and limitations of using interactive video technology to improve the quality of clinical trials are discussed.

  16. The Impact of Different Scoring Rubrics for Grading Virtual Patient-Based Exams

    ERIC Educational Resources Information Center

    Fors, Uno G. H.; Gunning, William T.

    2014-01-01

    Virtual patient cases (VPs) are used for healthcare education and assessment. Most VP systems track user interactions to be used for assessment. Few studies have investigated how virtual exam cases should be scored and graded. We have applied eight different scoring models on a data set from 154 students. Issues studied included the impact of…

  17. Pediatric Rapid Response Team: Vital Sign Based System vs. Pediatric Early Warning Score System

    DTIC Science & Technology

    2017-09-16

    quality improvement initiative using the evidence-based PEWS criteria to improve recognition of deteriorating pediatric patients, allocation of PRRT resources, and pediatric staff satisfaction regarding the PRRT process.

  18. JOURNAL CLUB: Assessment of Interobserver Variability in the Peer Review Process: Should We Agree to Disagree?

    PubMed

    Verma, Nupur; Hippe, Daniel S; Robinson, Jeffrey D

    2016-12-01

    Peer review is an important and necessary part of radiology. There are several options to perform the peer review process. This study examines the reproducibility of peer review by comparing two scoring systems. American Board of Radiology-certified radiologists from various practice environments and subspecialties were recruited to score deidentified examinations on a web-based PACS with two scoring systems, RADPEER and Cleareview. Quantitative analysis of the scores was performed for interrater agreement. Interobserver variability was high for both the RADPEER and Cleareview scoring systems. The interobserver correlations (kappa values) were 0.17-0.23 for RADPEER and 0.10-0.16 for Cleareview. Interrater correlation was not statistically significantly different when comparing the RADPEER and Cleareview systems (p = 0.07-0.27). The kappa values were low for the Cleareview subscores when we evaluated for missed findings (0.26), satisfaction of search (0.17), and inadequate interpretation of findings (0.12). Our study confirms the previous report of low interobserver correlation when using the peer review process. There was low interobserver agreement seen when using both the RADPEER and the Cleareview scoring systems.

  19. Impact on house staff evaluation scores when changing from a Dreyfus- to a Milestone-based evaluation model: one internal medicine residency program's findings.

    PubMed

    Friedman, Karen A; Balwan, Sandy; Cacace, Frank; Katona, Kyle; Sunday, Suzanne; Chaudhry, Saima

    2014-01-01

    Purpose As graduate medical education (GME) moves into the Next Accreditation System (NAS), programs must take a critical look at their current models of evaluation and assess how well they align with reporting outcomes. Our objective was to assess the impact on house staff evaluation scores when transitioning from a Dreyfus-based model of evaluation to a Milestone-based model of evaluation. Milestones are a key component of the NAS. Method We analyzed all end of rotation evaluations of house staff completed by faculty for academic years 2010-2011 (pre-Dreyfus model) and 2011-2012 (post-Milestone model) in one large university-based internal medicine residency training program. Main measures included change in PGY-level average score; slope, range, and separation of average scores across all six Accreditation Council for Graduate Medical Education (ACGME) competencies. Results Transitioning from a Dreyfus-based model to a Milestone-based model resulted in a larger separation in the scores between our three post-graduate year classes, a steeper progression of scores in the PGY-1 class, a wider use of the 5-point scale on our global end of rotation evaluation form, and a downward shift in the PGY-1 scores and an upward shift in the PGY-3 scores. Conclusions For faculty trained in both models of assessment, the Milestone-based model had greater discriminatory ability as evidenced by the larger separation in the scores for all the classes, in particular the PGY-1 class.

  20. Nursing activities score.

    PubMed

    Miranda, Dinis Reis; Nap, Raoul; de Rijk, Angelique; Schaufeli, Wilmar; Iapichino, Gaetano

    2003-02-01

    The instruments used for measuring nursing workload in the intensive care unit (e.g., Therapeutic Intervention Scoring System-28) are based on therapeutic interventions related to severity of illness. Many nursing activities are not necessarily related to severity of illness, and cost-effectiveness studies require the accurate evaluation of nursing activities. The aim of the study was to determine the nursing activities that best describe workload in the intensive care unit and to attribute weights to these activities so that the score describes average time consumption instead of severity of illness. To define by consensus a list of nursing activities, to determine the average time consumption of these activities by use of a 1-wk observational cross-sectional study, and to compare these results with those of the Therapeutic Intervention Scoring System-28. A total of 99 intensive care units in 15 countries. Consecutive admissions to the intensive care units. Daily recording of nursing activities at a patient level and random multimoment recording of these activities. A total of five new items and 14 subitems describing nursing activities in the intensive care unit (e.g., monitoring, care of relatives, administrative tasks) were added to the list of therapeutic interventions in Therapeutic Intervention Scoring System-28. Data from 2,041 patients (6,451 nursing days and 127,951 multimoment recordings) were analyzed. The new activities accounted for 60% of the average nursing time; the new scoring system (Nursing Activities Score) explained 81% of the nursing time (vs. 43% in Therapeutic Intervention Scoring System-28). The weights in the Therapeutic Intervention Scoring System-28 are not derived from the use of nursing time. Our study suggests that the Nursing Activities Score measures the consumption of nursing time in the intensive care unit. These results should be validated in independent databases.

  1. A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders

    PubMed Central

    Karbassi, Izabela; Maston, Glenn A.; Love, Angela; DiVincenzo, Christina; Braastad, Corey D.; Elzinga, Christopher D.; Bright, Alison R.; Previte, Domenic; Zhang, Ke; Rowland, Charles M.; McCarthy, Michele; Lapierre, Jennifer L.; Dubois, Felicita; Medeiros, Katelyn A.; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A.; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller‐Burckle, Arlene; Strom, Charles M.; Keiles, Steven B.

    2015-01-01

    ABSTRACT We developed a rules‐based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co‐occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re‐evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. PMID:26467025

  2. A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders.

    PubMed

    Karbassi, Izabela; Maston, Glenn A; Love, Angela; DiVincenzo, Christina; Braastad, Corey D; Elzinga, Christopher D; Bright, Alison R; Previte, Domenic; Zhang, Ke; Rowland, Charles M; McCarthy, Michele; Lapierre, Jennifer L; Dubois, Felicita; Medeiros, Katelyn A; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller-Burckle, Arlene; Strom, Charles M; Keiles, Steven B; Higgins, Joseph J

    2016-01-01

    We developed a rules-based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co-occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re-evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. © 2015 The Authors. **Human Mutation published by Wiley Periodicals, Inc.

  3. Analysis of confidence level scores from an ROC study: comparison of three mammographic systems for detection of simulated calcifications

    NASA Astrophysics Data System (ADS)

    Lai, Chao-Jen; Shaw, Chris C.; Whitman, Gary J.; Yang, Wei T.; Dempsey, Peter J.

    2005-04-01

    The purpose of this study is to compare the detection performance of three different mammography systems: screen/film (SF) combination, a-Si/CsI flat-panel (FP-), and charge-coupled device (CCD-) based systems. A 5-cm thick 50% adipose/50% glandular breast tissue equivalent slab phantom was used to provide an uniform background. Calcium carbonate grains of three different size groups were used to simulate microcalcifications (MCs): 112-125, 125-140, and 140-150 μm overlapping with the uniform background. Calcification images were acquired with the three mammography systems. Digital images were printed on hardcopy films. All film images were displayed on a mammographic viewer and reviewed by 5 mammographers. The visibility of the MC was rated with a 5-point confidence rating scale for each detection task, including the negative controls. Scores were averaged over all readers for various detectors and size groups. Receiver operating characteristic (ROC) analysis was performed and the areas under the ROC curves (Az"s) were computed for various imaging conditions. The results shows that (1) the FP-based system performed significantly better than the SF and CCD-based systems for individual size groups using ROC analysis (2) the FP-based system also performed significantly better than the SF and CCD-based systems for individual size groups using averaged confidence scale, and (3) the results obtained from the Az"s were largely correlated with these from confidence level scores. However, the correlation varied slightly among different imaging conditions.

  4. Rasch analysis of the Edmonton Symptom Assessment System and research implications.

    PubMed

    Cheifetz, O; Packham, T L; Macdermid, J C

    2014-04-01

    Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Polytomous Rasch analysis (Andrich's rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. The Rasch reliability index was 0.73, falling short of the desired 0.80-0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0-10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions.

  5. Using Multivariate Base Rates to Interpret Low Scores on an Abbreviated Battery of the Delis-Kaplan Executive Function System.

    PubMed

    Karr, Justin E; Garcia-Barrera, Mauricio A; Holdnack, James A; Iverson, Grant L

    2017-05-01

    Executive function consists of multiple cognitive processes that operate as an interactive system to produce volitional goal-oriented behavior, governed in large part by frontal microstructural and physiological networks. Identification of deficits in executive function in those with neurological or psychiatric conditions can be difficult because the normal variation in executive function test scores, in healthy adults when multiple tests are used, is largely unknown. This study addresses that gap in the literature by examining the prevalence of low scores on a brief battery of executive function tests. The sample consisted of 1,050 healthy individuals (ages 16-89) from the standardization sample for the Delis-Kaplan Executive Function System (D-KEFS). Seven individual test scores from the Trail Making Test, Color-Word Interference Test, and Verbal Fluency Test were analyzed. Low test scores, as defined by commonly used clinical cut-offs (i.e., ≤25th, 16th, 9th, 5th, and 2nd percentiles), occurred commonly among the adult portion of the D-KEFS normative sample (e.g., 62.8% of the sample had one or more scores ≤16th percentile, 36.1% had one or more scores ≤5th percentile), and the prevalence of low scores increased with lower intelligence and fewer years of education. The multivariate base rates (BR) in this article allow clinicians to understand the normal frequency of low scores in the general population. By use of these BRs, clinicians and researchers can improve the accuracy with which they identify executive dysfunction in clinical groups, such as those with traumatic brain injury or neurodegenerative diseases. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Diagnostic accuracy of sleep bruxism scoring in absence of audio-video recording: a pilot study.

    PubMed

    Carra, Maria Clotilde; Huynh, Nelly; Lavigne, Gilles J

    2015-03-01

    Based on the most recent polysomnographic (PSG) research diagnostic criteria, sleep bruxism is diagnosed when >2 rhythmic masticatory muscle activity (RMMA)/h of sleep are scored on the masseter and/or temporalis muscles. These criteria have not yet been validated for portable PSG systems. This pilot study aimed to assess the diagnostic accuracy of scoring sleep bruxism in absence of audio-video recordings. Ten subjects (mean age 24.7 ± 2.2) with a clinical diagnosis of sleep bruxism spent one night in the sleep laboratory. PSG were performed with a portable system (type 2) while audio-video was recorded. Sleep studies were scored by the same examiner three times: (1) without, (2) with, and (3) without audio-video in order to test the intra-scoring and intra-examiner reliability for RMMA scoring. The RMMA event-by-event concordance rate between scoring without audio-video and with audio-video was 68.3 %. Overall, the RMMA index was overestimated by 23.8 % without audio-video. However, the intra-class correlation coefficient (ICC) between scorings with and without audio-video was good (ICC = 0.91; p < 0.001); the intra-examiner reliability was high (ICC = 0.97; p < 0.001). The clinical diagnosis of sleep bruxism was confirmed in 8/10 subjects based on scoring without audio-video and in 6/10 subjects with audio-video. Although the absence of audio-video recording, the diagnostic accuracy of assessing RMMA with portable PSG systems appeared to remain good, supporting their use for both research and clinical purposes. However, the risk of moderate overestimation in absence of audio-video must be taken into account.

  7. Rationale for the new GP deprivation payment scheme in England: effects of moving from electoral ward to enumeration district underprivileged area scores.

    PubMed Central

    Bajekal, M; Alves, B; Jarman, B; Hurwitz, B

    2001-01-01

    BACKGROUND: The Department of Health introduced a new deprivation payments system for general practitioners (GPs) on 1 April 1999. Following a three-year phasing-in process, registered patients will attract deprivation payments based on the underprivileged area (UPA) score of their enumeration district (ED) of residence, rather than their electoral ward, changing the pattern and distribution of payments throughout England. AIM: To assess the rationale behind the changed deprivation payments system for GPs in England and to examine its impact on GP and practice payments. DESIGN OF STUDY: A quantitative study modelling practice-based deprivation payments. SETTING: A total of 25,450 unrestricted principal GPs in 8919 practices in England. METHOD: The effect of three new components in the system were examined: changes in the ED score ranges attracting payment, the percentage increase in the size of successive payment bands, and the total budget. The relationship between consultation rates (used as a proxy for workload) and UPA score was examined, together with changes in GP payments calculated nationally and by geographical area. RESULTS: A total of 11.6% of the population of England live in wards with a UPA score of 30 or more, qualifying for deprivation payments, and a similar proportion (11.4%) live in EDs with a UPA score of 20 or more. The larger percentage increases in the size of payments in successive ED UPA bands is supported by the modelled relationship between consultation rate and UPA score. Financially, under the new deprivations payment system, entitlement widens with 88% of practices receiving a payment. Overall, 74% of GPs gain and 13% lose (3% losing more than 1500 Pounds), with 13% receiving no payment. CONCLUSION: The new ED system maps onto the previous system well. Moreover, it more finely discriminates between smaller areas of different relative deprivation and, thereby, targets payments more accurately. PMID:11407049

  8. Rationale for the new GP deprivation payment scheme in England: effects of moving from electoral ward to enumeration district underprivileged area scores.

    PubMed

    Bajekal, M; Alves, B; Jarman, B; Hurwitz, B

    2001-06-01

    The Department of Health introduced a new deprivation payments system for general practitioners (GPs) on 1 April 1999. Following a three-year phasing-in process, registered patients will attract deprivation payments based on the underprivileged area (UPA) score of their enumeration district (ED) of residence, rather than their electoral ward, changing the pattern and distribution of payments throughout England. To assess the rationale behind the changed deprivation payments system for GPs in England and to examine its impact on GP and practice payments. A quantitative study modelling practice-based deprivation payments. A total of 25,450 unrestricted principal GPs in 8919 practices in England. The effect of three new components in the system were examined: changes in the ED score ranges attracting payment, the percentage increase in the size of successive payment bands, and the total budget. The relationship between consultation rates (used as a proxy for workload) and UPA score was examined, together with changes in GP payments calculated nationally and by geographical area. A total of 11.6% of the population of England live in wards with a UPA score of 30 or more, qualifying for deprivation payments, and a similar proportion (11.4%) live in EDs with a UPA score of 20 or more. The larger percentage increases in the size of payments in successive ED UPA bands is supported by the modelled relationship between consultation rate and UPA score. Financially, under the new deprivations payment system, entitlement widens with 88% of practices receiving a payment. Overall, 74% of GPs gain and 13% lose (3% losing more than 1500 Pounds), with 13% receiving no payment. The new ED system maps onto the previous system well. Moreover, it more finely discriminates between smaller areas of different relative deprivation and, thereby, targets payments more accurately.

  9. Establishment and validation of the scoring system for preoperative prediction of central lymph node metastasis in papillary thyroid carcinoma.

    PubMed

    Liu, Wen; Cheng, Ruochuan; Ma, Yunhai; Wang, Dan; Su, Yanjun; Diao, Chang; Zhang, Jianming; Qian, Jun; Liu, Jin

    2018-05-03

    Early preoperative diagnosis of central lymph node metastasis (CNM) is crucial to improve survival rates among patients with papillary thyroid carcinoma (PTC). Here, we analyzed clinical data from 2862 PTC patients and developed a scoring system using multivariable logistic regression and testified by the validation group. The predictive diagnostic effectiveness of the scoring system was evaluated based on consistency, discrimination ability, and accuracy. The scoring system considered seven variables: gender, age, tumor size, microcalcification, resistance index >0.7, multiple nodular lesions, and extrathyroid extension. The area under the receiver operating characteristic curve (AUC) was 0.742, indicating a good discrimination. Using 5 points as a diagnostic threshold, the validation results for validation group had an AUC of 0.758, indicating good discrimination and consistency in the scoring system. The sensitivity of this predictive model for preoperative diagnosis of CNM was 4 times higher than a direct ultrasound diagnosis. These data indicate that the CNM prediction model would improve preoperative diagnostic sensitivity for CNM in patients with papillary thyroid carcinoma.

  10. Recognition of medication information from discharge summaries using ensembles of classifiers.

    PubMed

    Doan, Son; Collier, Nigel; Xu, Hua; Pham, Hoang Duy; Tu, Minh Phuong

    2012-05-07

    Extraction of clinical information such as medications or problems from clinical text is an important task of clinical natural language processing (NLP). Rule-based methods are often used in clinical NLP systems because they are easy to adapt and customize. Recently, supervised machine learning methods have proven to be effective in clinical NLP as well. However, combining different classifiers to further improve the performance of clinical entity recognition systems has not been investigated extensively. Combining classifiers into an ensemble classifier presents both challenges and opportunities to improve performance in such NLP tasks. We investigated ensemble classifiers that used different voting strategies to combine outputs from three individual classifiers: a rule-based system, a support vector machine (SVM) based system, and a conditional random field (CRF) based system. Three voting methods were proposed and evaluated using the annotated data sets from the 2009 i2b2 NLP challenge: simple majority, local SVM-based voting, and local CRF-based voting. Evaluation on 268 manually annotated discharge summaries from the i2b2 challenge showed that the local CRF-based voting method achieved the best F-score of 90.84% (94.11% Precision, 87.81% Recall) for 10-fold cross-validation. We then compared our systems with the first-ranked system in the challenge by using the same training and test sets. Our system based on majority voting achieved a better F-score of 89.65% (93.91% Precision, 85.76% Recall) than the previously reported F-score of 89.19% (93.78% Precision, 85.03% Recall) by the first-ranked system in the challenge. Our experimental results using the 2009 i2b2 challenge datasets showed that ensemble classifiers that combine individual classifiers into a voting system could achieve better performance than a single classifier in recognizing medication information from clinical text. It suggests that simple strategies that can be easily implemented such as majority voting could have the potential to significantly improve clinical entity recognition.

  11. Disease scoring systems for oral lichen planus; a critical appraisal

    PubMed Central

    Wang, Jing

    2015-01-01

    The aim of the present study has been to critically review 22 disease scoring systems (DSSs) on oral lichen planus (OLP) that have been reported in the literature during the past decades. Although the presently available DSSs may all have some merit, particularly for research purposes, the diversity of both the objective and subjective parameters used in these systems and the lack of acceptance of one of these systems for uniform use, there is a need for an international, authorized consensus meeting on this subject. Because of the natural course of OLP characterized by remissions and exacerbations and also due to the varying distribution pattern and the varying clinical types, e.g. reticular and erosive, the relevance of a DSS based on morphologic parameters is somewhat questionable. Instead, one may consider to only look for a quality of life scoring system adapted for use in OLP patients. Key words:Oral lichen planus, disease scoring system, classification. PMID:25681372

  12. Scoring Methods for Building Genotypic Scores: An Application to Didanosine Resistance in a Large Derivation Set

    PubMed Central

    Houssaini, Allal; Assoumou, Lambert; Miller, Veronica; Calvez, Vincent; Marcelin, Anne-Geneviève; Flandre, Philippe

    2013-01-01

    Background Several attempts have been made to determine HIV-1 resistance from genotype resistance testing. We compare scoring methods for building weighted genotyping scores and commonly used systems to determine whether the virus of a HIV-infected patient is resistant. Methods and Principal Findings Three statistical methods (linear discriminant analysis, support vector machine and logistic regression) are used to determine the weight of mutations involved in HIV resistance. We compared these weighted scores with known interpretation systems (ANRS, REGA and Stanford HIV-db) to classify patients as resistant or not. Our methodology is illustrated on the Forum for Collaborative HIV Research didanosine database (N = 1453). The database was divided into four samples according to the country of enrolment (France, USA/Canada, Italy and Spain/UK/Switzerland). The total sample and the four country-based samples allow external validation (one sample is used to estimate a score and the other samples are used to validate it). We used the observed precision to compare the performance of newly derived scores with other interpretation systems. Our results show that newly derived scores performed better than or similar to existing interpretation systems, even with external validation sets. No difference was found between the three methods investigated. Our analysis identified four new mutations associated with didanosine resistance: D123S, Q207K, H208Y and K223Q. Conclusions We explored the potential of three statistical methods to construct weighted scores for didanosine resistance. Our proposed scores performed at least as well as already existing interpretation systems and previously unrecognized didanosine-resistance associated mutations were identified. This approach could be used for building scores of genotypic resistance to other antiretroviral drugs. PMID:23555613

  13. Usefulness of a clinical scoring system to anticipate difficulty of Norplant removal.

    PubMed

    Blumenthal, P D; Remsburg, R E; Glew, G; McGrath, J A; Gaffikin, L

    1995-12-01

    Removal of contraceptive implants (e.g. Norplant) is an issue affecting its worldwide acceptability. Reports of difficult, painful removals have resulted in lawsuits and reduced demand. To improve quality of care, we developed a scoring system to anticipate difficult removals. We report on the usefulness of such a system and present client perspectives about the removal experience. A 9-point scoring system based on the visibility, arrangement, and position (VAP) of Norplant capsules was used to assess the anticipated difficulty of removal in 53 consecutive patients. The VAP score was then correlated with removal time and related parameters. Mean removal time was 14.74 min (range 4.75-47). In 20% of patients, the VAP score indicated a potentially difficult removal and the VAP score correlated significantly with removal time (r = 0.3, p = 0.05). Patients expected removal to be moderately difficult (mean visual analog score 4.7 out of a possible 10), but after removal they rated the actual removal experience as relatively easy (mean score 2.6/10). Before the removal, only 48% of patients said they would recommend Norplant to a friend but after removal, 70% said they would do so. A scoring system such as the VAP score can help identify potentially difficult removals so that an experienced remover can be present at the time of removal or an appropriate referral made. However, the VAP score cannot predict variables such as the density of the subcutaneous fibrous tissue "envelope". Although patient anxiety concerning removal may be high, the presence of a competent remover and an easy removal experience reduces this anxiety and encourages patients to be more positive about this method. The value of having properly trained, competent personnel available to perform removals cannot be over-emphasized.

  14. CRISP: Catheterization RISk score for Pediatrics: A Report from the Congenital Cardiac Interventional Study Consortium (CCISC).

    PubMed

    Nykanen, David G; Forbes, Thomas J; Du, Wei; Divekar, Abhay A; Reeves, Jaxk H; Hagler, Donald J; Fagan, Thomas E; Pedra, Carlos A C; Fleming, Gregory A; Khan, Danyal M; Javois, Alexander J; Gruenstein, Daniel H; Qureshi, Shakeel A; Moore, Phillip M; Wax, David H

    2016-02-01

    We sought to develop a scoring system that predicts the risk of serious adverse events (SAE's) for individual pediatric patients undergoing cardiac catheterization procedures. Systematic assessment of risk of SAE in pediatric catheterization can be challenging in view of a wide variation in procedure and patient complexity as well as rapidly evolving technology. A 10 component scoring system was originally developed based on expert consensus and review of the existing literature. Data from an international multi-institutional catheterization registry (CCISC) between 2008 and 2013 were used to validate this scoring system. In addition we used multivariate methods to further refine the original risk score to improve its predictive power of SAE's. Univariate analysis confirmed the strong correlation of each of the 10 components of the original risk score with SAE attributed to a pediatric cardiac catheterization (P < 0.001 for all variables). Multivariate analysis resulted in a modified risk score (CRISP) that corresponds to an increase in value of area under a receiver operating characteristic curve (AUC) from 0.715 to 0.741. The CRISP score predicts risk of occurrence of an SAE for individual patients undergoing pediatric cardiac catheterization procedures. © 2015 Wiley Periodicals, Inc.

  15. Bowel Endometriosis Syndrome: a new scoring system for pelvic organ dysfunction and quality of life.

    PubMed

    Riiskjær, M; Egekvist, A G; Hartwell, D; Forman, A; Seyer-Hansen, M; Kesmodel, U S

    2017-09-01

    Is it possible to develop a validated score that can identify women with Bowel Endometriosis Syndrome (BENS) and be used to monitor the effect of medical and surgical treatment? The BENS score can be used to identify women with BENS and to monitor the effect of medical and surgical treatment of women suffering from bowel endometriosis. Endometriosis is a heterogeneous disease with extensive variation in anatomical and clinical presentation, and symptoms do not always correspond to the disease burden. Current endometriosis scoring systems are mainly based on anatomical and surgical findings. The score was developed and validated from a cohort of 525 women with medically or surgically treated bowel endometriosis from Aarhus and Copenhagen University Hospitals, Denmark. Patients filled in questionnaires on pelvic pain, quality of life (QoL) and urinary, sexual and bowel function. Items were selected for the final score using clinical and statistical criteria. The chosen variables were included in a multivariate analysis. Individual score values were designated items to form the BENS score, which was divided into 'no BENS', 'minor BENS' and 'major BENS.' Internal and external validations were performed. The six most important items were 'pelvic pain', 'use of analgesics', 'dyschezia', 'straining to urinate', 'fecal urgency' and 'satisfaction with sexual life'. The range of the BENS score (0-28) was divided into 0-8 (no BENS), 9-16 (minor BENS) and 17-28 (major BENS). External validation showed a significant association between BENS score and QoL (P = 0.0001). The BENS scoring system is limited by the fact that it was developed from a single endometriosis unit in Denmark, making it susceptible to social, cultural and demographic bias. It is the first endometriosis classification system to be based directly on the symptomatology of the patient. Validation in other languages will promote comparison of treatments and results across borders. No external funding was either sought or obtained for this study. A.F. is an investigator for Bayer, outside this work. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  16. Evaluation of a novel scoring and grading model for VP-based exams in postgraduate nurse education.

    PubMed

    Forsberg, Elenita; Ziegert, Kristina; Hult, Håkan; Fors, Uno

    2015-12-01

    For Virtual Patient-based exams, several scoring and grading methods have been proposed, but none have yet been validated. The aim of this study was to evaluate a new scoring and grading model for VP-based exams in postgraduate paediatric nurse education. The same student group of 19 students performed a VP-based exam in three consecutive courses. When using the scoring and grading assessment model, which contains a deduction system for unnecessary or unwanted actions, a progression was found in the three courses: 53% of the students passed the first exam, 63% the second and 84% passed the final exam. The most common reason for deduction of points was due to students asking too many interview questions or ordering too many laboratory tests. The results showed that the new scoring model made it possible to judge the students' clinical reasoning process as well as their progress. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Proposing Melasma Severity Index: A New, More Practical, Office-based Scoring System for Assessing the Severity of Melasma

    PubMed Central

    Majid, Imran; Haq, Inaamul; Imran, Saher; Keen, Abid; Aziz, Khalid; Arif, Tasleem

    2016-01-01

    Background: Melasma Area and Severity Index (MASI), the scoring system in melasma, needs to be refined. Aims and Objectives: To propose a more practical scoring system, named as Melasma Severity Index (MSI), for assessing the disease severity and treatment response in melasma. Materials and Methods: Four dermatologists were trained to calculate MASI and also the proposed MSI scores. For MSI, the formula used was 0.4 (a × p2) l + 0.4 (a × p2) r + 0.2 (a × p2) n where “a” stands for area, “p” for pigmentation, “l” for left face, “r” for right face, and “n” for nose. On a single day, 30 enrolled patients were randomly examined by each trained dermatologist and their MASI and MSI scores were calculated. Next, each rater re-examined every 6th patient for repeat MASI and MSI scoring to assess intra- and inter-rater reliability of MASI and MSI scores. Validity was assessed by comparing the individual scores of each rater with objective data from mexameter and ImageJ software. Results: Inter-rater reliability, as assessed by intraclass correlation coefficient, was significantly higher for MSI (0.955) as compared to MASI (0.816). Correlation of scores with objective data by Spearman's correlation revealed higher rho values for MSI than for MASI for all raters. Limitations: Sample population belonged to a single ethnic group. Conclusions: MSI is simpler and more practical scoring system for melasma. PMID:26955093

  18. A metadata-aware application for remote scoring and exchange of tissue microarray images

    PubMed Central

    2013-01-01

    Background The use of tissue microarrays (TMA) and advances in digital scanning microscopy has enabled the collection of thousands of tissue images. There is a need for software tools to annotate, query and share this data amongst researchers in different physical locations. Results We have developed an open source web-based application for remote scoring of TMA images, which exploits the value of Microsoft Silverlight Deep Zoom to provide a intuitive interface for zooming and panning around digital images. We use and extend existing XML-based standards to ensure that the data collected can be archived and that our system is interoperable with other standards-compliant systems. Conclusion The application has been used for multi-centre scoring of TMA slides composed of tissues from several Phase III breast cancer trials and ten different studies participating in the International Breast Cancer Association Consortium (BCAC). The system has enabled researchers to simultaneously score large collections of TMA and export the standardised data to integrate with pathological and clinical outcome data, thereby facilitating biomarker discovery. PMID:23635078

  19. A practical scoring system to predict mortality in patients with perforated peptic ulcer.

    PubMed

    Menekse, Ebru; Kocer, Belma; Topcu, Ramazan; Olmez, Aydemir; Tez, Mesut; Kayaalp, Cuneyt

    2015-01-01

    The mortality rate of perforated peptic ulcer is still high particularly for aged patients and all the existing scoring systems to predict mortality are complicated or based on history taking which is not always reliable for elderly patients. This study's aim was to develop an easy and applicable scoring system to predict mortality based on hospital admission data. Total 227 patients operated for perforated peptic ulcer in two centers were included. All data that may be potential predictors with respect to hospital mortality were retrospectively analyzed. The mortality and morbidity rates were 10.1% and 24.2%, respectively. Multivariated analysis pointed out three parameters corresponding 1 point for each which were age >65 years, albumin ≤1,5 g/dl and BUN >45 mg/dl. Its prediction rate was high with 0,931 (95% CI, 0,890 to 0,961) value of AUC. The hospital mortality rates for none, one, two and three positive results were zero, 7.1%, 34.4% and 88.9%, respectively. Because the new system consists only age and routinely measured two simple laboratory tests (albumin and BUN), its application is easy and prediction power is satisfactory. Verification of this new scoring system is required by large scale multicenter studies.

  20. Which functionalities are available in the electronic health record systems used by French general practitioners? An assessment study of 15 systems.

    PubMed

    Darmon, David; Sauvant, Rémy; Staccini, Pascal; Letrilliart, Laurent

    2014-01-01

    Whereas an unprecedented effort is currently under way worldwide for the implementation of electronic health record (EHR) systems, their capabilities are poorly understood, especially in primary care. The objective of this study was to assess the main functionalities of the EHR systems used in French general practices. Among the 20 EHR systems marketed in France, we assessed the 15 systems used by more than 1500 general practitioners in the Provence-Alpes-Côte d'Azur region in the southeast part of France. Each EHR system was assessed in a general practice office, using two clinical vignettes describing virtual patient consultations. The evaluation criteria were derived from the EuroRec requirements for EHR system quality. The assessment scale included 37 criteria grouped into three sets: background data, consultation data, and exchange functionalities. The scoring system used, totalling 64 points, was based on the validation of the criteria and was adjusted based on the possibility of standardising the data. A high score indicated a good EHR system quality. The median global score was 32 points out of a possible 64 (range: 20-39). The median score was 12 points out of 22 (range: 6-15) for the background data set, 16 points out of 32 (range: 9-22) for the consultation data set, and four points out of 10 (range: 0-6) for the exchange functionalities. No association was found between the number of users and the assessment score of the EHR systems (p=0.79). One third of the EHR systems lacked a problem list and only one of them supported the episode of care. Functionalities noticeably vary among the EHR systems currently used in French primary care. Whereas these systems are globally very focused on drug prescriptions, several core functionalities are frequently lacking. They are also poorly interoperable for healthcare professionals and patients. Further research is necessary to assess their actual use. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Structural and Sequence Similarity Makes a Significant Impact on Machine-Learning-Based Scoring Functions for Protein-Ligand Interactions.

    PubMed

    Li, Yang; Yang, Jianyi

    2017-04-24

    The prediction of protein-ligand binding affinity has recently been improved remarkably by machine-learning-based scoring functions. For example, using a set of simple descriptors representing the atomic distance counts, the RF-Score improves the Pearson correlation coefficient to about 0.8 on the core set of the PDBbind 2007 database, which is significantly higher than the performance of any conventional scoring function on the same benchmark. A few studies have been made to discuss the performance of machine-learning-based methods, but the reason for this improvement remains unclear. In this study, by systemically controlling the structural and sequence similarity between the training and test proteins of the PDBbind benchmark, we demonstrate that protein structural and sequence similarity makes a significant impact on machine-learning-based methods. After removal of training proteins that are highly similar to the test proteins identified by structure alignment and sequence alignment, machine-learning-based methods trained on the new training sets do not outperform the conventional scoring functions any more. On the contrary, the performance of conventional functions like X-Score is relatively stable no matter what training data are used to fit the weights of its energy terms.

  2. A network-based dynamical ranking system for competitive sports

    NASA Astrophysics Data System (ADS)

    Motegi, Shun; Masuda, Naoki

    2012-12-01

    From the viewpoint of networks, a ranking system for players or teams in sports is equivalent to a centrality measure for sports networks, whereby a directed link represents the result of a single game. Previously proposed network-based ranking systems are derived from static networks, i.e., aggregation of the results of games over time. However, the score of a player (or team) fluctuates over time. Defeating a renowned player in the peak performance is intuitively more rewarding than defeating the same player in other periods. To account for this factor, we propose a dynamic variant of such a network-based ranking system and apply it to professional men's tennis data. We derive a set of linear online update equations for the score of each player. The proposed ranking system predicts the outcome of the future games with a higher accuracy than the static counterparts.

  3. A Survey of Attitudes towards the Clinical Application of Systemic Inflammation Based Prognostic Scores in Cancer.

    PubMed

    Watt, David G; Roxburgh, Campbell S; White, Mark; Chan, Juen Zhik; Horgan, Paul G; McMillan, Donald C

    2015-01-01

    The systemic inflammatory response (SIR) plays a key role in determining nutritional status and survival of patients with cancer. A number of objective scoring systems have been shown to have prognostic value; however, their application in routine clinical practice is not clear. The aim of the present survey was to examine the range of opinions internationally on the routine use of these scoring systems. An online survey was distributed to a target group consisting of individuals worldwide who have reported an interest in systemic inflammation in patients with cancer. Of those invited by the survey (n = 238), 65% routinely measured the SIR, mainly for research and prognostication purposes and clinically for allocation of adjuvant therapy or palliative chemotherapy. 40% reported that they currently used the Glasgow Prognostic Score/modified Glasgow Prognostic Score (GPS/mGPS) and 81% reported that a measure of systemic inflammation should be incorporated into clinical guidelines, such as the definition of cachexia. The majority of respondents routinely measured the SIR in patients with cancer, mainly using the GPS/mGPS for research and prognostication purposes. The majority reported that a measure of the SIR should be adopted into clinical guidelines.

  4. How education systems shape cross-national ethnic inequality in math competence scores: Moving beyond mean differences

    PubMed Central

    Spörlein, Christoph

    2018-01-01

    Here we examine a conceptualization of immigrant assimilation that is based on the more general notion that distributional differences erode across generations. We explore this idea by reinvestigating the efficiency-equality trade-off hypothesis, which posits that stratified education systems educate students more efficiently at the cost of increasing inequality in overall levels of competence. In the context of ethnic inequality in math achievement, this study explores the extent to which an education system’s characteristics are associated with ethnic inequality in terms of both the group means and group variances in achievement. Based on data from the 2012 PISA and mixed-effect location scale models, our analyses revealed two effects: on average, minority students had lower math scores than majority students, and minority students’ scores were more concentrated at the lower end of the distribution. However, the ethnic inequality in the distribution of scores declined across generations. We did not find compelling evidence that stratified education systems increase mean differences in competency between minority and majority students. However, our analyses revealed that in countries with early educational tracking, minority students’ math scores tended to cluster at the lower end of the distribution, regardless of compositional and school differences between majority and minority students. PMID:29494677

  5. STONE score versus Guy's Stone Score - prospective comparative evaluation for success rate and complications in percutaneous nephrolithotomy

    PubMed Central

    Kumar, Ujwal; Tomar, Vinay; Yadav, Sher Singh; Priyadarshi, Shivam; Vyas, Nachiket; Agarwal, Neeraj; Dayal, Ram

    2018-01-01

    Purpose: The aim of the current study was to compare Guy's score and STONE score in predicting the success and complication rate of percutaneous nephrolithotomy (PCNL). Materials and Methods: A total of 445 patients were included in the study between July 2015 and December 2016. The patients were given STONE score and Guy's Stone Score (GSS) grades based on CT scan done preoperatively and intra- and post-operative complications were graded using the modified Clavien grading system. The PCNL were done by a standard technique in prone positions. Results: The success rate in our study was 86.29% and both the GSS and STONE score were significantly associated with a success rate of the procedure. Both the scoring systems correlated with operative time and postoperative hospital stay. Of the total cases, 102 patients (22.92%) experienced complications. A correlation between STONE score stratified into low, moderate, and high nephrolithometry score risk groups (low scores 4–5, moderate scores 6–8, high scores 9–13), and complication was also found (P = 0.04) but not between the GSS and complication rate (P = 0.054). Conclusion: Both GSS and STONE scores are equally effective in predicting success rate of the procedure. PMID:29416280

  6. Design Patterns Application in the ERP Systems Improvements

    NASA Astrophysics Data System (ADS)

    Jovičić, Bojan; Vlajić, Siniša

    Design patterns application have long been present in software engineering. The same is true for ERP systems in business software. Is it possible that ERP systems do not have a good maintenance score? We have found out that there is room for maintenance improvement and that it is possible to improve ERP systems using design patterns. We have conducted comparative analysis of ease of maintenance of the ERP systems. The results show that the average score for our questions is 64%, with most answers for ERP systems like SAP, Oracle EBS, Dynamics AX. We found that 59% of ERP system developer users are not familiar with design patterns. Based on this research, we have chosen Dynamics AX as the ERP system for examination of design patterns improvement possibilities. We used software metrics to measure improvement possibility. We found that we could increase the Conditional Complexity score 17-fold by introducing design patterns.

  7. A Systems Study to Determine the Attractiveness of Solar System Bodies and Sites for Eventual Human Exploration

    NASA Technical Reports Server (NTRS)

    Andringa, Jason M.; Gray, Andrew A.

    2005-01-01

    A pre-phase A idea-generation team at the Jet Propulsion Laboratory (JPL), has conducted a study to rank all locations in the solar system based on attractiveness for human exploration. The process used to perform the study was composed of the following primary steps: determination of criteria (including value, cost, and risk criteria) upon which to rate sites in the solar system; weighting of the criteria based upon importance to eventual human exploration; selection of sites to consider and assignment of team members to the task of advocating the benefits of particular sites; rating the sites in both the short- and longterm based on team member presentations and team discussions; compilation of a score based on criteria weights and individual ratings. Finally a comparison of the total scores of different sites was completed to determine a ranking of all the bodies and sites in the solar system. Sensitivity analysis was also performed to determine how weightings affect the rankings.

  8. An EEG-Based Person Authentication System with Open-Set Capability Combining Eye Blinking Signals

    PubMed Central

    Wu, Qunjian; Zeng, Ying; Zhang, Chi; Tong, Li; Yan, Bin

    2018-01-01

    The electroencephalogram (EEG) signal represents a subject’s specific brain activity patterns and is considered as an ideal biometric given its superior forgery prevention. However, the accuracy and stability of the current EEG-based person authentication systems are still unsatisfactory in practical application. In this paper, a multi-task EEG-based person authentication system combining eye blinking is proposed, which can achieve high precision and robustness. Firstly, we design a novel EEG-based biometric evoked paradigm using self- or non-self-face rapid serial visual presentation (RSVP). The designed paradigm could obtain a distinct and stable biometric trait from EEG with a lower time cost. Secondly, the event-related potential (ERP) features and morphological features are extracted from EEG signals and eye blinking signals, respectively. Thirdly, convolutional neural network and back propagation neural network are severally designed to gain the score estimation of EEG features and eye blinking features. Finally, a score fusion technology based on least square method is proposed to get the final estimation score. The performance of multi-task authentication system is improved significantly compared to the system using EEG only, with an increasing average accuracy from 92.4% to 97.6%. Moreover, open-set authentication tests for additional imposters and permanence tests for users are conducted to simulate the practical scenarios, which have never been employed in previous EEG-based person authentication systems. A mean false accepted rate (FAR) of 3.90% and a mean false rejected rate (FRR) of 3.87% are accomplished in open-set authentication tests and permanence tests, respectively, which illustrate the open-set authentication and permanence capability of our systems. PMID:29364848

  9. An EEG-Based Person Authentication System with Open-Set Capability Combining Eye Blinking Signals.

    PubMed

    Wu, Qunjian; Zeng, Ying; Zhang, Chi; Tong, Li; Yan, Bin

    2018-01-24

    The electroencephalogram (EEG) signal represents a subject's specific brain activity patterns and is considered as an ideal biometric given its superior forgery prevention. However, the accuracy and stability of the current EEG-based person authentication systems are still unsatisfactory in practical application. In this paper, a multi-task EEG-based person authentication system combining eye blinking is proposed, which can achieve high precision and robustness. Firstly, we design a novel EEG-based biometric evoked paradigm using self- or non-self-face rapid serial visual presentation (RSVP). The designed paradigm could obtain a distinct and stable biometric trait from EEG with a lower time cost. Secondly, the event-related potential (ERP) features and morphological features are extracted from EEG signals and eye blinking signals, respectively. Thirdly, convolutional neural network and back propagation neural network are severally designed to gain the score estimation of EEG features and eye blinking features. Finally, a score fusion technology based on least square method is proposed to get the final estimation score. The performance of multi-task authentication system is improved significantly compared to the system using EEG only, with an increasing average accuracy from 92.4% to 97.6%. Moreover, open-set authentication tests for additional imposters and permanence tests for users are conducted to simulate the practical scenarios, which have never been employed in previous EEG-based person authentication systems. A mean false accepted rate (FAR) of 3.90% and a mean false rejected rate (FRR) of 3.87% are accomplished in open-set authentication tests and permanence tests, respectively, which illustrate the open-set authentication and permanence capability of our systems.

  10. Tracking Success in Large Introductory Classes using Technology

    NASA Astrophysics Data System (ADS)

    Robertson, Thomas H.

    2011-01-01

    A common problem frequently encountered in large introductory classes is the anonymity experienced by students. An effort is underway at Ball State University to explore the impact of technology on reducing this anonymity and improving student performance and success. In preparation for this study, performance and success measures for students in a previous class have been examined to provide background for construction of a model for formal testing and a control group for comparison of future results. Student performance measures obtained early in the course and final course grades were examined to identify potential early warning indicators that might be used to plan interventions much earlier than the traditional midterm course reports used to alert freshmen at academic risk. Class participation scores were based on data obtained with a personal response system (i>clicker). The scores were scaled to reflect about 80% comprehension and 20% attendance. Homework scores were obtained using the LON-CAPA Course Management System and instructional materials created by the author. Substantial linear correlations exist between 1) Exam 1 Scores after Four Weeks and 2) Raw Class Participation Scores for the First Six Weeks and the Final Course Score. A more modest linear correlation was found between 3) Homework Scores for First Six Weeks and Final Course Score. Of these three measures, only Class Participation Scores identified all students who ultimately received course grades lower than C. Several students scored in the danger zone according to Homework and Class Participation Scores but earned course grades of C or better. It appears that an early warning plan based on Class Participation Scores would permit effective identification of at-risk students early in the course.

  11. A visual system for scoring body condition of Asian elephants (Elephas maximus).

    PubMed

    Wijeyamohan, Shanmugasundaram; Treiber, Kibby; Schmitt, Dennis; Santiapillai, Charles

    2015-01-01

    A body condition score (BCS) may provide information on the health or production potential of an animal; it may also reflect the suitability of the environment to maintain an animal population. Thus assessing the BCS of Asian elephants is important for their management. There is a need for a robust BCS applicable to both wild and captive elephants of all age categories based on the minimum and maximum possible subcutaneous body fat and muscle deposits. The visually based system for scoring the body condition of elephants presented here satisfies these criteria and is quick, inexpensive, non-invasive and user-friendly in the field. The BCS scale correlates (P < 0.05) with morphometric indices such as weight, girth, and skin fold measures. © 2014 Wiley Periodicals, Inc.

  12. Standardizing an approach to the evaluation of implementation science proposals.

    PubMed

    Crable, Erika L; Biancarelli, Dea; Walkey, Allan J; Allen, Caitlin G; Proctor, Enola K; Drainoni, Mari-Lynn

    2018-05-29

    The fields of implementation and improvement sciences have experienced rapid growth in recent years. However, research that seeks to inform health care change may have difficulty translating core components of implementation and improvement sciences within the traditional paradigms used to evaluate efficacy and effectiveness research. A review of implementation and improvement sciences grant proposals within an academic medical center using a traditional National Institutes of Health framework highlighted the need for tools that could assist investigators and reviewers in describing and evaluating proposed implementation and improvement sciences research. We operationalized existing recommendations for writing implementation science proposals as the ImplemeNtation and Improvement Science Proposals Evaluation CriTeria (INSPECT) scoring system. The resulting system was applied to pilot grants submitted to a call for implementation and improvement science proposals at an academic medical center. We evaluated the reliability of the INSPECT system using Krippendorff's alpha coefficients and explored the utility of the INSPECT system to characterize common deficiencies in implementation research proposals. We scored 30 research proposals using the INSPECT system. Proposals received a median cumulative score of 7 out of a possible score of 30. Across individual elements of INSPECT, proposals scored highest for criteria rating evidence of a care or quality gap. Proposals generally performed poorly on all other criteria. Most proposals received scores of 0 for criteria identifying an evidence-based practice or treatment (50%), conceptual model and theoretical justification (70%), setting's readiness to adopt new services/treatment/programs (54%), implementation strategy/process (67%), and measurement and analysis (70%). Inter-coder reliability testing showed excellent reliability (Krippendorff's alpha coefficient 0.88) for the application of the scoring system overall and demonstrated reliability scores ranging from 0.77 to 0.99 for individual elements. The INSPECT scoring system presents a new scoring criteria with a high degree of inter-rater reliability and utility for evaluating the quality of implementation and improvement sciences grant proposals.

  13. Predictive value of seven preoperative prognostic scoring systems for spinal metastases

    PubMed Central

    Leithner, Andreas; Radl, Roman; Gruber, Gerald; Hochegger, Markus; Leithner, Katharina; Welkerling, Heike; Rehak, Peter

    2008-01-01

    Predicting prognosis is the key factor in selecting the proper treatment modality for patients with spinal metastases. Therefore, various assessment systems have been designed in order to provide a basis for deciding the course of treatment. Such systems have been proposed by Tokuhashi, Sioutos, Tomita, Van der Linden, and Bauer. The scores differ greatly in the kind of parameters assessed. The aim of this study was to evaluate the prognostic value of each score. Eight parameters were assessed for 69 patients (37 male, 32 female): location, general condition, number of extraspinal bone metastases, number of spinal metastases, visceral metastases, primary tumour, severity of spinal cord palsy, and pathological fracture. Scores according to Tokuhashi (original and revised), Sioutos, Tomita, Van der Linden, and Bauer were assessed as well as a modified Bauer score without scoring for pathologic fracture. Nineteen patients were still alive as of September 2006 with a minimum follow-up of 12 months. All other patients died after a mean period of 17 months after operation. The mean overall survival period was only 3 months for lung cancer, followed by prostate (7 months), kidney (23 months), breast (35 months), and multiple myeloma (51 months). At univariate survival analysis, primary tumour and visceral metastases were significant parameters, while Karnofsky score was only significant in the group including myeloma patients. In multivariate analysis of all seven parameters assessed, primary tumour and visceral metastases were the only significant parameters. Of all seven scoring systems, the original Bauer score and a Bauer score without scoring for pathologic fracture had the best association with survival (P < 0.001). The data of the present study emphasize that the original Bauer score and a modified Bauer score without scoring for pathologic fracture seem to be practicable and highly predictive preoperative scoring systems for patients with spinal metastases. However, decision for or against surgery should never be based alone on a prognostic score but should take symptoms like pain or neurological compromise into account. PMID:18787846

  14. A battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people.

    PubMed

    Shinmoto Torres, Roberto L; Visvanathan, Renuka; Abbott, Derek; Hill, Keith D; Ranasinghe, Damith C

    2017-01-01

    Falls in hospitals are common, therefore strategies to minimize the impact of these events in older patients and needs to be examined. In this pilot study, we investigate a movement monitoring sensor system for identifying bed and chair exits using a wireless wearable sensor worn by hospitalized older patients. We developed a movement monitoring sensor system that recognizes bed and chair exits. The system consists of a machine learning based activity classifier and a bed and chair exit recognition process based on an activity score function. Twenty-six patients, aged 71 to 93 years old, hospitalized in the Geriatric Evaluation and Management Unit participated in the supervised trials. They wore over their attire a battery-less, lightweight and wireless sensor and performed scripted activities such as getting off the bed and chair. We investigated the system performance in recognizing bed and chair exits in hospital rooms where RFID antennas and readers were in place. The system's acceptability was measured using two surveys with 0-10 likert scales. The first survey measured the change in user perception of the system before and after a trial; the second survey, conducted only at the end of each trial, measured user acceptance of the system based on a multifactor sensor acceptance model. The performance of the system indicated an overall recall of 81.4%, precision of 66.8% and F-score of 72.4% for joint bed and chair exit recognition. Patients demonstrated improved perception of the system after use with overall score change from 7.8 to 9.0 and high acceptance of the system with score ≥ 6.7 for all acceptance factors. The present pilot study suggests the use of wireless wearable sensors is feasible for detecting bed and chair exits in a hospital environment.

  15. Pediatric Heart Donor Assessment Tool (PH-DAT): A novel donor risk scoring system to predict 1-year mortality in pediatric heart transplantation.

    PubMed

    Zafar, Farhan; Jaquiss, Robert D; Almond, Christopher S; Lorts, Angela; Chin, Clifford; Rizwan, Raheel; Bryant, Roosevelt; Tweddell, James S; Morales, David L S

    2018-03-01

    In this study we sought to quantify hazards associated with various donor factors into a cumulative risk scoring system (the Pediatric Heart Donor Assessment Tool, or PH-DAT) to predict 1-year mortality after pediatric heart transplantation (PHT). PHT data with complete donor information (5,732) were randomly divided into a derivation cohort and a validation cohort (3:1). From the derivation cohort, donor-specific variables associated with 1-year mortality (exploratory p-value < 0.2) were incorporated into a multivariate logistic regression model. Scores were assigned to independent predictors (p < 0.05) based on relative odds ratios (ORs). The final model had an acceptable predictive value (c-statistic = 0.62). The significant 5 variables (ischemic time, stroke as the cause of death, donor-to-recipient height ratio, donor left ventricular ejection fraction, glomerular filtration rate) were used for the scoring system. The validation cohort demonstrated a strong correlation between the observed and expected rates of 1-year mortality (r = 0.87). The risk of 1-year mortality increases by 11% (OR 1.11 [1.08 to 1.14]; p < 0.001) in the derivation cohort and 9% (OR 1.09 [1.04 to 1.14]; p = 0.001) in the validation cohort with an increase of 1-point in score. Mortality risk increased 5 times from the lowest to the highest donor score in this cohort. Based on this model, a donor score range of 10 to 28 predicted 1-year recipient mortality of 11% to 31%. This novel pediatric-specific, donor risk scoring system appears capable of predicting post-transplant mortality. Although the PH-DAT may benefit organ allocation and assessment of recipient risk while controlling for donor risk, prospective validation of this model is warranted. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Validation of a Clinical Scoring System for Outcome Prediction in Dogs with Acute Kidney Injury Managed by Hemodialysis.

    PubMed

    Segev, G; Langston, C; Takada, K; Kass, P H; Cowgill, L D

    2016-05-01

    A scoring system for outcome prediction in dogs with acute kidney injury (AKI) recently has been developed but has not been validated. The scoring system previously developed for outcome prediction will accurately predict outcome in a validation cohort of dogs with AKI managed with hemodialysis. One hundred fifteen client-owned dogs with AKI. Medical records of dogs with AKI treated by hemodialysis between 2011 and 2015 were reviewed. Dogs were included only if all variables required to calculate the final predictive score were available, and the 30-day outcome was known. A predictive score for 3 models was calculated for each dog. Logistic regression was used to evaluate the association of the final predictive score with each model's outcome. Receiver operating curve (ROC) analyses were performed to determine sensitivity and specificity for each model based on previously established cut-off values. Higher scores for each model were associated with decreased survival probability (P < .001). Based on previously established cut-off values, 3 models (models A, B, C) were associated with sensitivities/specificities of 73/75%, 71/80%, and 75/86%, respectively, and correctly classified 74-80% of the dogs. All models were simple to apply and allowed outcome prediction that closely corresponded with actual outcome in an independent cohort. As expected, accuracies were slightly lower compared with those from the previously reported cohort used initially to develop the models. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Cyber Contingency Analysis version 1.x

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Contingency analysis based approach for quantifying and examining the resiliency of a cyber system in respect to confidentiality, integrity and availability. A graph representing an organization's cyber system and related resources is used for the availability contingency analysis. The mission critical paths associated with an organization are used to determine the consequences of a potential contingency. A node (or combination of nodes) are removed from the graph to analyze a particular contingency. The value of all mission critical paths that are disrupted by that contingency are used to quantify its severity. A total severity score can be calculated based onmore » the complete list of all these contingencies. A simple n1 analysis can be done in which only one node is removed at a time for the analysis. We can also compute nk analysis, where k is the number of nodes to simultaneously remove for analysis. A contingency risk score can also be computed, which takes the probability of the contingencies into account. In addition to availability, we can also quantify confidentiality and integrity scores for the system. These treat user accounts as potential contingencies. The amount (and type) of files that an account can read to is used to compute the confidentiality score. The amount (and type) of files that an account can write to is used to compute the integrity score. As with availability analysis, we can use this information to compute total severity scores in regards to confidentiality and integrity. We can also take probability into account to compute associated risk scores.« less

  18. Quantification of protein expression in cells and cellular subcompartments on immunohistochemical sections using a computer supported image analysis system.

    PubMed

    Braun, Martin; Kirsten, Robert; Rupp, Niels J; Moch, Holger; Fend, Falko; Wernert, Nicolas; Kristiansen, Glen; Perner, Sven

    2013-05-01

    Quantification of protein expression based on immunohistochemistry (IHC) is an important step for translational research and clinical routine. Several manual ('eyeballing') scoring systems are used in order to semi-quantify protein expression based on chromogenic intensities and distribution patterns. However, manual scoring systems are time-consuming and subject to significant intra- and interobserver variability. The aim of our study was to explore, whether new image analysis software proves to be sufficient as an alternative tool to quantify protein expression. For IHC experiments, one nucleus specific marker (i.e., ERG antibody), one cytoplasmic specific marker (i.e., SLC45A3 antibody), and one marker expressed in both compartments (i.e., TMPRSS2 antibody) were chosen. Stainings were applied on TMAs, containing tumor material of 630 prostate cancer patients. A pathologist visually quantified all IHC stainings in a blinded manner, applying a four-step scoring system. For digital quantification, image analysis software (Tissue Studio v.2.1, Definiens AG, Munich, Germany) was applied to obtain a continuous spectrum of average staining intensity. For each of the three antibodies we found a strong correlation of the manual protein expression score and the score of the image analysis software. Spearman's rank correlation coefficient was 0.94, 0.92, and 0.90 for ERG, SLC45A3, and TMPRSS2, respectively (p⟨0.01). Our data suggest that the image analysis software Tissue Studio is a powerful tool for quantification of protein expression in IHC stainings. Further, since the digital analysis is precise and reproducible, computer supported protein quantification might help to overcome intra- and interobserver variability and increase objectivity of IHC based protein assessment.

  19. Modified TIME-H: a simplified scoring system for chronic wound management.

    PubMed

    Lim, K; Free, B; Sinha, S

    2015-09-01

    Chronic wound assessment requires a systematic approach in order to guide management and improve prognostication. Following a pilot study using the original TIME-H scoring system in chronic wound management, modifications were suggested leading to the development of the Modified TIME-H scoring system. This study investigates the feasibility and reliability of chronic wound prognostication applying the Modified TIME-H score. Patients referred to the hospital's outpatient wound clinic over a 9-month period were categorised into one of three predicted outcome categories based on their Modified TIME-H score. This study shows a higher proportion of patients in the certain healing category achieved healed wounds, with a higher rate of reduction in wound size, when compared with the other categories. The three categories defined in this study are certain healing, uncertain healing and difficult healing. The Modified TIME-H score could be a useful tool for assessment, patient-centred management and prognostication of chronic wounds in clinical practice and requires further validation from other institutions. The authors have no conflict of interest to declare.

  20. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman.

    PubMed

    Panzer, Stephanie; Pernter, Patrizia; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zesch, Stephanie; Rosendahl, Wilfried; Hotz, Gerhard; Zink, Albert R

    2017-12-01

    Purpose  Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the "Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies" to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. Materials and Methods  A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6 mm; kilovolt ranging from 80 to 140). For standardized evaluation the "CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies" was used. Results  All checkpoints under category "A. Soft Tissues of Head and Musculoskeletal System" and more than half in category "B. Organs and Organ Systems" were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Conclusion  Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation. Key Points   · The approach of structured reporting can be transferred to paleoradiology.. · The checklist allowed for standardized soft tissue assessment and documentation.. · The scoring system facilitated a quantitative comparison among mummies.. · Based on CT, the Tyrolean Iceman demonstrated remarkable soft tissue preservation.. Citation Format · Panzer S, Pernter P, Piombino-Mascali D et al. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman. Fortschr Röntgenstr 2017; 189: 1152 - 1160. © Georg Thieme Verlag KG Stuttgart · New York.

  1. 42 CFR § 414.1380 - Scoring.

    Code of Federal Regulations, 2010 CFR

    2017-10-01

    ...) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Merit-Based Incentive Payment System and Alternative Payment Model Incentive § 414.1380 Scoring. (a) General. MIPS eligible... payment year 2019. Instead, these measures as well as measures that are below the data completeness...

  2. A predictive scoring system for insufficient liver hypertrophy after preoperative portal vein embolization.

    PubMed

    Watanabe, Nobuyuki; Yamamoto, Yusuke; Sugiura, Teiichi; Okamura, Yukiyasu; Ito, Takaaki; Ashida, Ryo; Aramaki, Takeshi; Uesaka, Katsuhiko

    2018-05-01

    The factors which affect hypertrophy of the future liver remnant after portal vein embolization remain unclear. The aim of this study was to clarify the clinical factors affecting the hypertrophy rate after portal vein embolization and to develop a scoring system predicting insufficient liver hypertrophy. The cases of a total of 152 patients who underwent portal vein embolization of the right portal branch between 2006 and 2016 were reviewed retrospectively. The score to predict insufficient (<25%) hypertrophy was established based on logistic regression analyses of the clinical parameters before portal vein embolization. After portal vein embolization, the future liver remnant volume, expressed as the median (range), significantly increased from 364 (151-801) mL, 33% (18%-54%), to 451 (242-866) mL, 42% (26%-65%). The median hypertrophy rate was 24% (-5% to 96%). A preoperative predictive scoring system for insufficient liver hypertrophy was constructed using the following 3 factors: an initial future liver remnant volume ≥35% (2 points), alkaline phosphatase ≥450 IU/dL (1 point), and cholinesterase <220 mg/dL (1 point). The constructed scoring system indicated the proportion of patients with insufficient liver hypertrophy (<25%) to be 6 out of 42 (14%) in the low-score group (0 points), 44 out of 77 (57%) in the medium-score group (1-2 points), and 30 out of 33 (91%) in the high-score group (3-4 points). The hypertrophy rate of future liver remnant was different among the 3 groups (low-score group, 38.9% [-2.4% to 81.4%]; medium-score group, 22.7% [-5.1% to 95.5%]; high-score group, 18.2% [2.4%-30.7%]) (P < .001). The constructed scoring system was able to stratify patients before portal vein embolization according to the possibility of developing insufficient liver hypertrophy. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Age, PaO2/FIO2, and Plateau Pressure Score: A Proposal for a Simple Outcome Score in Patients With the Acute Respiratory Distress Syndrome.

    PubMed

    Villar, Jesús; Ambrós, Alfonso; Soler, Juan Alfonso; Martínez, Domingo; Ferrando, Carlos; Solano, Rosario; Mosteiro, Fernando; Blanco, Jesús; Martín-Rodríguez, Carmen; Fernández, María Del Mar; López, Julia; Díaz-Domínguez, Francisco J; Andaluz-Ojeda, David; Merayo, Eleuterio; Pérez-Méndez, Lina; Fernández, Rosa Lidia; Kacmarek, Robert M

    2016-07-01

    Although there is general agreement on the characteristic features of the acute respiratory distress syndrome, we lack a scoring system that predicts acute respiratory distress syndrome outcome with high probability. Our objective was to develop an outcome score that clinicians could easily calculate at the bedside to predict the risk of death of acute respiratory distress syndrome patients 24 hours after diagnosis. A prospective, multicenter, observational, descriptive, and validation study. A network of multidisciplinary ICUs. Six-hundred patients meeting Berlin criteria for moderate and severe acute respiratory distress syndrome enrolled in two independent cohorts treated with lung-protective ventilation. None. Using individual demographic, pulmonary, and systemic data at 24 hours after acute respiratory distress syndrome diagnosis, we derived our prediction score in 300 acute respiratory distress syndrome patients based on stratification of variable values into tertiles, and validated in an independent cohort of 300 acute respiratory distress syndrome patients. Primary outcome was in-hospital mortality. We found that a 9-point score based on patient's age, PaO2/FIO2 ratio, and plateau pressure at 24 hours after acute respiratory distress syndrome diagnosis was associated with death. Patients with a score greater than 7 had a mortality of 83.3% (relative risk, 5.7; 95% CI, 3.0-11.0), whereas patients with scores less than 5 had a mortality of 14.5% (p < 0.0000001). We confirmed the predictive validity of the score in a validation cohort. A simple 9-point score based on the values of age, PaO2/FIO2 ratio, and plateau pressure calculated at 24 hours on protective ventilation after acute respiratory distress syndrome diagnosis could be used in real time for rating prognosis of acute respiratory distress syndrome patients with high probability.

  4. Value-based purchasing and hospital acquired conditions: are we seeing improvement?

    PubMed

    Spaulding, Aaron; Zhao, Mei; Haley, D Rob

    2014-12-01

    To determine if the Value-Based Purchasing Performance Scoring system correlates with hospital acquired condition quality indicators. This study utilizes the following secondary data sources: the American Hospital Association (AHA) annual survey and the Centers for Medicare and Medicaid (CMS) Value-Based Purchasing and Hospital Acquired Conditions databases. Zero-inflated negative binomial regression was used to examine the effect of CMS total performance score on counts of hospital acquired conditions. Hospital structure variables including size, ownership, teaching status, payer mix, case mix, and location were utilized as control variables. The secondary data sources were merged into a single database using Stata 10. Total performance scores, which are used to determine if hospitals should receive incentive money, do not correlate well with quality outcome in the form of hospital acquired conditions. Value-based purchasing does not appear to correlate with improved quality and patient safety as indicated by Hospital Acquired Condition (HAC) scores. This leads us to believe that either the total performance score does not measure what it should, or the quality outcome measurements do not reflect the quality of the total performance scores measure. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. An Automatic Assessment System of Diabetic Foot Ulcers Based on Wound Area Determination, Color Segmentation, and Healing Score Evaluation.

    PubMed

    Wang, Lei; Pedersen, Peder C; Strong, Diane M; Tulu, Bengisu; Agu, Emmanuel; Ignotz, Ron; He, Qian

    2015-08-07

    For individuals with type 2 diabetes, foot ulcers represent a significant health issue. The aim of this study is to design and evaluate a wound assessment system to help wound clinics assess patients with foot ulcers in a way that complements their current visual examination and manual measurements of their foot ulcers. The physical components of the system consist of an image capture box, a smartphone for wound image capture and a laptop for analyzing the wound image. The wound image assessment algorithms calculate the overall wound area, color segmented wound areas, and a healing score, to provide a quantitative assessment of the wound healing status both for a single wound image and comparisons of subsequent images to an initial wound image. The system was evaluated by assessing foot ulcers for 12 patients in the Wound Clinic at University of Massachusetts Medical School. As performance measures, the Matthews correlation coefficient (MCC) value for the wound area determination algorithm tested on 32 foot ulcer images was .68. The clinical validity of our healing score algorithm relative to the experienced clinicians was measured by Krippendorff's alpha coefficient (KAC) and ranged from .42 to .81. Our system provides a promising real-time method for wound assessment based on image analysis. Clinical comparisons indicate that the optimized mean-shift-based algorithm is well suited for wound area determination. Clinical evaluation of our healing score algorithm shows its potential to provide clinicians with a quantitative method for evaluating wound healing status. © 2015 Diabetes Technology Society.

  6. A system to evaluate the scientific quality of biological and restoration objectives using National Wildlife Refuge Comprehensive Conservation Plans as a case study

    USGS Publications Warehouse

    Schroeder, R.L.

    2006-01-01

    It is widely accepted that plans for restoration projects should contain specific, measurable, and science-based objectives to guide restoration efforts. The United States Fish and Wildlife Service (USFWS) is in the process of developing Comprehensive Conservation Plans (CCPs) for more than 500 units in the National Wildlife Refuge System (NWRS). These plans contain objectives for biological and ecosystem restoration efforts on the refuges. Based on USFWS policy, a system was developed to evaluate the scientific quality of such objectives based on three critical factors: (1) Is the objective specific, measurable, achievable, results-oriented, and time-fixed? (2) What is the extent of the rationale that explains the assumptions, logic, and reasoning for the objective? (3) How well was available science used in the development of the objective? The evaluation system scores each factor on a scale of 1 (poor) to 4 (excellent) according to detailed criteria. The biological and restoration objectives from CCPs published as of September 2004 (60 total) were evaluated. The overall average score for all biological and restoration objectives was 1.73. Average scores for each factor were: Factor 1-1.97; Factor 2-1.86; Factor 3-1.38. The overall scores increased from 1997 to 2004. Future restoration efforts may benefit by using this evaluation system during the process of plan development, to ensure that biological and restoration objectives are of the highest scientific quality possible prior to the implementation of restoration plans, and to allow for improved monitoring and adaptive management.

  7. Privacy Impact Assessment for the Lead-based Paint System of Records

    EPA Pesticide Factsheets

    The Lead-based Paint System of Records collects personally identifiable information, test scores, and submitted fees. Learn how this data is collected, how it will be used, access to the data, the purpose of data collection, and record retention policies.

  8. The feasibility of sharing simulation-based evaluation scenarios in anesthesiology.

    PubMed

    Berkenstadt, Haim; Kantor, Gareth S; Yusim, Yakov; Gafni, Naomi; Perel, Azriel; Ezri, Tiberiu; Ziv, Amitai

    2005-10-01

    We prospectively assessed the feasibility of international sharing of simulation-based evaluation tools despite differences in language, education, and anesthesia practice, in an Israeli study, using validated scenarios from a multi-institutional United States (US) study. Thirty-one Israeli junior anesthesia residents performed four simulation scenarios. Training sessions were videotaped and performance was assessed using two validated scoring systems (Long and Short Forms) by two independent raters. Subjects scored from 37 to 95 (70 +/- 12) of 108 possible points with the "Long Form" and "Short Form" scores ranging from 18 to 35 (28.2 +/- 4.5) of 40 possible points. Scores >70% of the maximal score were achieved by 61% of participants in comparison to only 5% in the original US study. The scenarios were rated as very realistic by 80% of the participants (grade 4 on a 1-4 scale). Reliability of the original assessment tools was demonstrated by internal consistencies of 0.66 for the Long and 0.75 for the Short Form (Cronbach alpha statistic). Values in the original study were 0.72-0.76 for the Long and 0.71-0.75 for the Short Form. The reliability did not change when a revised Israeli version of the scoring was used. Interrater reliability measured by Pearson correlation was 0.91 for the Long and 0.96 for the Short Form (P < 0.01). The high scores for plausibility given to the scenarios and the similar reliability of the original assessment tool support the feasibility of using simulation-based evaluation tools, developed in the US, in Israel. The higher scores achieved by Israeli residents may be related to the fact that most Israeli residents are immigrants with previous training in anesthesia. Simulation-based assessment tools developed in a multi-institutional study in the United States can be used in Israel despite the differences in language, education, and medical system.

  9. The ACTA PORT-score for predicting perioperative risk of blood transfusion for adult cardiac surgery.

    PubMed

    Klein, A A; Collier, T; Yeates, J; Miles, L F; Fletcher, S N; Evans, C; Richards, T

    2017-09-01

    A simple and accurate scoring system to predict risk of transfusion for patients undergoing cardiac surgery is lacking. We identified independent risk factors associated with transfusion by performing univariate analysis, followed by logistic regression. We then simplified the score to an integer-based system and tested it using the area under the receiver operator characteristic (AUC) statistic with a Hosmer-Lemeshow goodness-of-fit test. Finally, the scoring system was applied to the external validation dataset and the same statistical methods applied to test the accuracy of the ACTA-PORT score. Several factors were independently associated with risk of transfusion, including age, sex, body surface area, logistic EuroSCORE, preoperative haemoglobin and creatinine, and type of surgery. In our primary dataset, the score accurately predicted risk of perioperative transfusion in cardiac surgery patients with an AUC of 0.76. The external validation confirmed accuracy of the scoring method with an AUC of 0.84 and good agreement across all scores, with a minor tendency to under-estimate transfusion risk in very high-risk patients. The ACTA-PORT score is a reliable, validated tool for predicting risk of transfusion for patients undergoing cardiac surgery. This and other scores can be used in research studies for risk adjustment when assessing outcomes, and might also be incorporated into a Patient Blood Management programme. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. The normalization of data in the Constant-Murley score for the shoulder. A study conducted on 563 healthy subjects.

    PubMed

    Grassi, F A; Tajana, M S

    2003-01-01

    The study was conducted in order to evaluate the theoretical design of the Constant-Murley system and to reveal any difficulties in obtaining data when it is used in 563 subjects not affected with shoulder pathology. The total mean score for the subjects examined was 85.2 points (minimum 75, maximum 100 points). Values revealed a decreasing trend beginning at 50 years of age for men and 30 for women. Only 4 subjects achieved a maximum score of 100. The measurements taken allowed us to elaborate a reference table based on sex and age, which was required to calculate the correct score. These values differ from those reported by the inventors of the system and they reveal the need to compile personal tables for the normalization of scores.

  11. Histopathological Validation of the Surface-Intermediate-Base Margin Score for Standardized Reporting of Resection Technique during Nephron Sparing Surgery.

    PubMed

    Minervini, Andrea; Campi, Riccardo; Kutikov, Alexander; Montagnani, Ilaria; Sessa, Francesco; Serni, Sergio; Raspollini, Maria Rosaria; Carini, Marco

    2015-10-01

    The surface-intermediate-base margin score is a novel standardized reporting system of resection techniques during nephron sparing surgery. We validated the surgeon assessed surface-intermediate-base score with microscopic histopathological assessment of partial nephrectomy specimens. Between June and August 2014 data were prospectively collected from 40 consecutive patients undergoing nephron sparing surgery. The surface-intermediate-base score was assigned to all cases. The score specific areas were color coded with tissue margin ink and sectioned for histological evaluation of healthy renal margin thickness. Maximum, minimum and mean thickness of healthy renal margin for each score specific area grade (surface [S] = 0, S = 1 ; intermediate [I] or base [B] = 0, I or B = 1, I or B = 2) was reported. The Mann-Whitney U and Kruskal-Wallis tests were used to compare the thickness of healthy renal margin in S = 0 vs 1 and I or B = 0 vs 1 vs 2 grades, respectively. Maximum, minimum and mean thickness of healthy renal margin was significantly different among score specific area grades S = 0 vs 1, and I or B = 0 vs 1, 0 vs 2 and 1 vs 2 (p <0.001). The main limitations of the study are the low number of the I or B = 1 and I or B = 2 samples and the assumption that each microscopic slide reflects the entire score specific area for histological analysis. The surface-intermediate-base scoring method can be readily harnessed in real-world clinical practice and accurately mirrors histopathological analysis for quantification and reporting of healthy renal margin thickness removed during tumor excision. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Serum lactate dehydrogenase with a systemic inflammation score is useful for predicting response and survival in patients with newly diagnosed diffuse large B-cell lymphoma.

    PubMed

    Jung, Sung-Hoon; Yang, Deok-Hwan; Ahn, Jae-Sook; Kim, Yeo-Kyeoung; Kim, Hyeoung-Joon; Lee, Je-Jung

    2015-01-01

    We evaluated the relationship between serum lactate dehydrogenase (LDH) level with systemic inflammation score and survival in 213 patients with diffuse large B-cell lymphoma (DLBCL) receiving R-CHOP chemotherapy. The patients were classified into 3 groups based on LDH with the Glasgow Prognostic Score (L-GPS). A score of 2 was assigned to patients with elevated C-reactive protein, hypoalbuminemia and elevated LDH, a score of 1 to those with one or two abnormalities and a score of 0 to those with no abnormality. In multivariate analysis, independent poor prognostic factors for progression-free survival were L-GPS 2 [hazard ratio (HR) 5.415, p = 0.001], Eastern Cooperative Oncology Group performance status (ECOG PS) ≥2 (HR 3.504, p = 0.001) and bulky lesion (HR 2.030, p = 0.039). Independent poor prognostic factors for overall survival were L-GPS 2 (HR 5.898, p = 0.001) and ECOG PS ≥2 (HR 3.525, p = 0.001). The overall response rate for the R-CHOP chemotherapy decreased according to the L-GPS; it was 96.7% at L-GPS 0, 87% at L-GPS 1 and 75% at L-GPS 2 (p = 0.009). L-GPS based on systemic inflammatory indicators may be a useful clinical prognostic indicator for survival, and predicts the response for R-CHOP chemotherapy in patients with newly diagnosed DLBCL. © 2014 S. Karger AG, Basel.

  13. Critical appraisal of emergency medicine education research: the best publications of 2013.

    PubMed

    Farrell, Susan E; Kuhn, Gloria J; Coates, Wendy C; Shayne, Phillip H; Fisher, Jonathan; Maggio, Lauren A; Lin, Michelle

    2014-11-01

    The objective was to critically appraise and highlight methodologically superior medical education research articles published in 2013 whose outcomes are pertinent to teaching and education in emergency medicine (EM). A search of the English-language literature in 2013 querying Education Resources Information Center (ERIC), PsychINFO, PubMed, and Scopus identified 251 EM-related studies using hypothesis-testing or observational investigations of educational interventions. Two reviewers independently screened all of the publications and removed articles using established exclusion criteria. Six reviewers then independently scored the remaining 43 publications using either a qualitative a or quantitative scoring system, based on the research methodology of each article. Each scoring system consisted of nine criteria. Selected criteria were based on accepted educational review literature and chosen a priori. Both scoring systems used parallel scoring metrics and have been used previously within this annual review. Forty-three medical education research papers (37 quantitative and six qualitative studies) met the a priori criteria for inclusion and were reviewed. Six quantitative and one qualitative study were scored and ranked most highly by the reviewers as exemplary and are summarized in this article. This annual critical appraisal article aims to promote superior research in EM-related education, by reviewing and highlighting seven of 43 major education research studies, meeting a priori criteria, and published in 2013. Common methodologic pitfalls in the 2013 papers are noted, and current trends in medical education research in EM are discussed. © 2014 by the Society for Academic Emergency Medicine.

  14. The mortality risk score and the ADG score: two points-based scoring systems for the Johns Hopkins aggregated diagnosis groups to predict mortality in a general adult population cohort in Ontario, Canada.

    PubMed

    Austin, Peter C; Walraven, Carl van

    2011-10-01

    Logistic regression models that incorporated age, sex, and indicator variables for the Johns Hopkins' Aggregated Diagnosis Groups (ADGs) categories have been shown to accurately predict all-cause mortality in adults. To develop 2 different point-scoring systems using the ADGs. The Mortality Risk Score (MRS) collapses age, sex, and the ADGs to a single summary score that predicts the annual risk of all-cause death in adults. The ADG Score derives weights for the individual ADG diagnosis groups. : Retrospective cohort constructed using population-based administrative data. All 10,498,413 residents of Ontario, Canada, between the age of 20 and 100 years who were alive on their birthday in 2007, participated in this study. Participants were randomly divided into derivation and validation samples. : Death within 1 year. In the derivation cohort, the MRS ranged from -21 to 139 (median value 29, IQR 17 to 44). In the validation group, a logistic regression model with the MRS as the sole predictor significantly predicted the risk of 1-year mortality with a c-statistic of 0.917. A regression model with age, sex, and the ADG Score has similar performance. Both methods accurately predicted the risk of 1-year mortality across the 20 vigintiles of risk. The MRS combined values for a person's age, sex, and the John Hopkins ADGs to accurately predict 1-year mortality in adults. The ADG Score is a weighted score representing the presence or absence of the 32 ADG diagnosis groups. These scores will facilitate health services researchers conducting risk adjustment using administrative health care databases.

  15. A battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people

    PubMed Central

    Visvanathan, Renuka; Abbott, Derek; Hill, Keith D.; Ranasinghe, Damith C.

    2017-01-01

    Falls in hospitals are common, therefore strategies to minimize the impact of these events in older patients and needs to be examined. In this pilot study, we investigate a movement monitoring sensor system for identifying bed and chair exits using a wireless wearable sensor worn by hospitalized older patients. We developed a movement monitoring sensor system that recognizes bed and chair exits. The system consists of a machine learning based activity classifier and a bed and chair exit recognition process based on an activity score function. Twenty-six patients, aged 71 to 93 years old, hospitalized in the Geriatric Evaluation and Management Unit participated in the supervised trials. They wore over their attire a battery-less, lightweight and wireless sensor and performed scripted activities such as getting off the bed and chair. We investigated the system performance in recognizing bed and chair exits in hospital rooms where RFID antennas and readers were in place. The system’s acceptability was measured using two surveys with 0–10 likert scales. The first survey measured the change in user perception of the system before and after a trial; the second survey, conducted only at the end of each trial, measured user acceptance of the system based on a multifactor sensor acceptance model. The performance of the system indicated an overall recall of 81.4%, precision of 66.8% and F-score of 72.4% for joint bed and chair exit recognition. Patients demonstrated improved perception of the system after use with overall score change from 7.8 to 9.0 and high acceptance of the system with score ≥ 6.7 for all acceptance factors. The present pilot study suggests the use of wireless wearable sensors is feasible for detecting bed and chair exits in a hospital environment. PMID:29016696

  16. SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olch, A

    2015-06-15

    Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Elevenmore » neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has provded a license for the software described.« less

  17. Reproducibility of the NEPTUNE descriptor-based scoring system on whole-slide images and histologic and ultrastructural digital images.

    PubMed

    Barisoni, Laura; Troost, Jonathan P; Nast, Cynthia; Bagnasco, Serena; Avila-Casado, Carmen; Hodgin, Jeffrey; Palmer, Matthew; Rosenberg, Avi; Gasim, Adil; Liensziewski, Chrysta; Merlino, Lino; Chien, Hui-Ping; Chang, Anthony; Meehan, Shane M; Gaut, Joseph; Song, Peter; Holzman, Lawrence; Gibson, Debbie; Kretzler, Matthias; Gillespie, Brenda W; Hewitt, Stephen M

    2016-07-01

    The multicenter Nephrotic Syndrome Study Network (NEPTUNE) digital pathology scoring system employs a novel and comprehensive methodology to document pathologic features from whole-slide images, immunofluorescence and ultrastructural digital images. To estimate inter- and intra-reader concordance of this descriptor-based approach, data from 12 pathologists (eight NEPTUNE and four non-NEPTUNE) with experience from training to 30 years were collected. A descriptor reference manual was generated and a webinar-based protocol for consensus/cross-training implemented. Intra-reader concordance for 51 glomerular descriptors was evaluated on jpeg images by seven NEPTUNE pathologists scoring 131 glomeruli three times (Tests I, II, and III), each test following a consensus webinar review. Inter-reader concordance of glomerular descriptors was evaluated in 315 glomeruli by all pathologists; interstitial fibrosis and tubular atrophy (244 cases, whole-slide images) and four ultrastructural podocyte descriptors (178 cases, jpeg images) were evaluated once by six and five pathologists, respectively. Cohen's kappa for inter-reader concordance for 48/51 glomerular descriptors with sufficient observations was moderate (0.40

  18. A case-oriented web-based training system for breast cancer diagnosis.

    PubMed

    Huang, Qinghua; Huang, Xianhai; Liu, Longzhong; Lin, Yidi; Long, Xingzhang; Li, Xuelong

    2018-03-01

    Breast cancer is still considered as the most common form of cancer as well as the leading causes of cancer deaths among women all over the world. We aim to provide a web-based breast ultrasound database for online training inexperienced radiologists and giving computer-assisted diagnostic information for detection and classification of the breast tumor. We introduce a web database which stores breast ultrasound images from breast cancer patients as well as their diagnostic information. A web-based training system using a feature scoring scheme based on Breast Imaging Reporting and Data System (BI-RADS) US lexicon was designed. A computer-aided diagnosis (CAD) subsystem was developed to assist the radiologists to make scores on the BI-RADS features for an input case. The training system possesses 1669 scored cases, where 412 cases are benign and 1257 cases are malignant. It was tested by 31 users including 12 interns, 11 junior radiologists, and 8 experienced senior radiologists. This online training system automatically creates case-based exercises to train and guide the newly employed or resident radiologists for the diagnosis of breast cancer using breast ultrasound images based on the BI-RADS. After the trainings, the interns and junior radiologists show significant improvement in the diagnosis of the breast tumor with ultrasound imaging (p-value < .05); meanwhile the senior radiologists show little improvement (p-value > .05). The online training system can improve the capabilities of early-career radiologists in distinguishing between the benign and malignant lesions and reduce the misdiagnosis of breast cancer in a quick, convenient and effective manner. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  19. Integrating Iris and Signature Traits for Personal Authentication Using User-Specific Weighting

    PubMed Central

    Viriri, Serestina; Tapamo, Jules R.

    2012-01-01

    Biometric systems based on uni-modal traits are characterized by noisy sensor data, restricted degrees of freedom, non-universality and are susceptible to spoof attacks. Multi-modal biometric systems seek to alleviate some of these drawbacks by providing multiple evidences of the same identity. In this paper, a user-score-based weighting technique for integrating the iris and signature traits is presented. This user-specific weighting technique has proved to be an efficient and effective fusion scheme which increases the authentication accuracy rate of multi-modal biometric systems. The weights are used to indicate the importance of matching scores output by each biometrics trait. The experimental results show that our biometric system based on the integration of iris and signature traits achieve a false rejection rate (FRR) of 0.08% and a false acceptance rate (FAR) of 0.01%. PMID:22666032

  20. Measurement of COPD Severity Using a Survey-Based Score

    PubMed Central

    Omachi, Theodore A.; Katz, Patricia P.; Yelin, Edward H.; Iribarren, Carlos; Blanc, Paul D.

    2010-01-01

    Background: A comprehensive survey-based COPD severity score has usefulness for epidemiologic and health outcomes research. We previously developed and validated the survey-based COPD Severity Score without using lung function or other physiologic measurements. In this study, we aimed to further validate the severity score in a different COPD cohort and using a combination of patient-reported and objective physiologic measurements. Methods: Using data from the Function, Living, Outcomes, and Work cohort study of COPD, we evaluated the concurrent and predictive validity of the COPD Severity Score among 1,202 subjects. The survey instrument is a 35-point score based on symptoms, medication and oxygen use, and prior hospitalization or intubation for COPD. Subjects were systemically assessed using structured telephone survey, spirometry, and 6-min walk testing. Results: We found evidence to support concurrent validity of the score. Higher COPD Severity Score values were associated with poorer FEV1 (r = −0.38), FEV1% predicted (r = −0.40), Body mass, Obstruction, Dyspnea, Exercise Index (r = 0.57), and distance walked in 6 min (r = −0.43) (P < .0001 in all cases). Greater COPD severity was also related to poorer generic physical health status (r = −0.49) and disease-specific health-related quality of life (r = 0.57) (P < .0001). The score also demonstrated predictive validity. It was also associated with a greater prospective risk of acute exacerbation of COPD defined as ED visits (hazard ratio [HR], 1.31; 95% CI, 1.24-1.39), hospitalizations (HR, 1.59; 95% CI, 1.44-1.75), and either measure of hospital-based care for COPD (HR, 1.34; 95% CI, 1.26-1.41) (P < .0001 in all cases). Conclusion: The COPD Severity Score is a valid survey-based measure of disease-specific severity, both in terms of concurrent and predictive validity. The score is a psychometrically sound instrument for use in epidemiologic and outcomes research in COPD. PMID:20040611

  1. Test-Based Accountability: The Promise and the Perils

    ERIC Educational Resources Information Center

    Loveless, Tom

    2005-01-01

    In the early 1990s, states began establishing standards in academic subjects backed by test-based accountability systems to see that the standards were met. Incentives were implemented for schools and students based on pupil test scores. These early accountability systems paved the way for passage of landmark federal legislation, the No Child Left…

  2. The corneal transplant score: a simple corneal graft candidate calculator.

    PubMed

    Rosenfeld, Eldar; Varssano, David

    2013-07-01

    Shortage of corneas for transplantation has created long waiting lists in most countries. Transplant calculators are available for many organs. The purpose of this study is to describe a simple automatic scoring system for keratoplasty recipient candidates, based on several parameters that we consider most relevant for tissue allocation, and to compare the system's accuracy in predicting decisions made by a cornea specialist. Twenty pairs of candidate data were randomly created on an electronic spreadsheet. A single priority score was computed from the data of each candidate. A cornea surgeon and the automated system then decided independently which candidate in each pair should have surgery if only a single cornea was available. The scoring system can calculate values between 0 (lowest priority) and 18 (highest priority) for each candidate. Average score value in our randomly created cohort was 6.35 ± 2.38 (mean ± SD), range 1.28 to 10.76. Average score difference between the candidates in each pair was 3.12 ± 2.10, range 0.08 to 8.45. The manual scoring process, although theoretical, was mentally and emotionally demanding for the surgeon. Agreement was achieved between the human decision and the calculated value in 19 of 20 pairs. Disagreement was reached in the pair with the lowest score difference (0.08). With worldwide donor cornea shortage, waiting for transplantation can be long. Manual sorting of priority for transplantation in a long waiting list is difficult, time-consuming and prone to error. The suggested system may help achieve a justified distribution of available tissue.

  3. A SCORING SYSTEM TO IMPROVE DECISION MAKING AND OUTCOMES IN THE ADAPTATION OF RECENTLY CAPTURED WHITE RHINOCEROSES (CERATOTHERIUM SIMUM) TO CAPTIVITY.

    PubMed

    Miller, Michele; Kruger, Milandie; Kruger, Marius; Olea-Popelka, Francisco; Buss, Peter

    2016-04-01

    Ninety-four subadult and adult white rhinoceroses (Ceratotherium simum) were captured between February and October, 2009-11, in Kruger National Park and placed in holding bomas prior to translocation to other locations within South Africa. A simple three-category system was developed based on appetite, fecal consistency/volume, and behavior to assess adaptation to bomas. Individual animal and group daily median scores were used to determine trends and when rhinoceroses had successfully adapted to the boma. Seventeen rhinoceroses did not adapt to boma confinement, and 16 were released (1 mortality). No differences in boma scores were observed between rhinoceroses that adapted and those that did not, until day 8, when the first significant differences were observed (adapted score=13 versus nonadapted score=10). The time to reach a boma score determined as successful adaptation (median 19 d) matched subjective observations, which was approximately 3 wk for most rhinoceroses. Unsuccessful adaptation was indicated by an individual boma score of less than 15, typically during the first 2 wk, or a declining trend in scores within the first 7-14 d. This scoring system can be used for most locations and could also be easily adapted to other areas in which rhinoceroses are held in captivity. This tool also provides important information for assessing welfare in newly captured rhinoceroses.

  4. Evaluation of Barrier Skin Cream Effectiveness Against JP-8 Jet Fuel Absorption and Irritation

    DTIC Science & Technology

    2009-04-01

    quantify the colorimeter measurements. This system uses spectral chromaticity coordinates and corresponding color- matching functions based on...in the caudal thigh or lumbar muscles and the rabbit was monitored throughout the procedure. Once anesthetized, a baseline visual and colorimeter ...Visual Scoring Technique All barrier creams were scored in 3 ways; by visual scoring described in the Draize method, by colorimeter , and by

  5. The MMPI Assistant: A Microcomputer Based Expert System to Assist in Interpreting MMPI Profiles

    PubMed Central

    Tanner, Barry A.

    1989-01-01

    The Assistant is an MS DOS program to aid clinical psychologists in interpreting the results of the Minnesota Multiphasic Personality Inventory (MMPI). Interpretive hypotheses are based on the professional literature and the author's experience. After scores are entered manually, the Assistant produces a hard copy which is intended for use by a psychologist knowledgeable about the MMPI. The rules for each hypothesis appear first on the monitor, and then in the printed output, followed by the patient's scores on the relevant scales, and narrative hypotheses for the scores. The data base includes hypotheses for 23 validity configurations, 45 two-point clinical codes, 10 high scoring single-point clinical scales, and 10 low scoring single-point clinical scales. The program can accelerate the production of test reports, while insuring that actuarial rules are not overlooked. It has been especially useful as a teaching tool with graduate students. The Assistant requires an IBM PC compatible with 128k available memory, DOS 2.x or higher, and a printer.

  6. Development of pig welfare assessment protocol integrating animal-, environment-, and management-based measures.

    PubMed

    Renggaman, Anriansyah; Choi, Hong L; Sudiarto, Sartika Ia; Alasaarela, Laura; Nam, Ok S

    2015-01-01

    Due to increased interest in animal welfare, there is now a need for a comprehensive assessment protocol to be used in intensive pig farming systems. There are two current welfare assessment protocols for pigs: Welfare Quality® Assessment Protocols (applicable in the Europe Union), that mostly focuses on animal-based measures, and the Swine Welfare Assurance Program (applicable in the United States), that mostly focuses on management- and environment-based measures. In certain cases, however, animal-based measures might not be adequate for properly assessing pig welfare status. Similarly, welfare assessment that relies only on environment- and management-based measures might not represent the actual welfare status of pigs. Therefore, the objective of this paper was to develop a new welfare protocol by integrating animal-, environment-, and management-based measures. The background for selection of certain welfare criteria and modification of the scoring systems from existing welfare assessment protocols are described. The developed pig welfare assessment protocol consists of 17 criteria that are related to four main principles of welfare (good feeding, good housing, good health, and appropriate behavior). Good feeding, good housing, and good health were assessed using a 3-point scale: 0 (good welfare), 1 (moderate welfare), and 2 (poor welfare). In certain cases, only a 2-point scale was used: 0 (certain condition is present) or 2 (certain condition is absent). Appropriate behavior was assessed by scan sampling of positive and negative social behaviors based on qualitative behavior assessment and human-animal relationship tests. Modification of the body condition score into a 3-point scale revealed pigs with a moderate body condition (score 1). Moreover, additional criteria such as feed quality confirmed that farms had moderate (score 1) or poor feed quality (score 2), especially those farms located in a high relative humidity region. The developed protocol can be utilized to assess welfare status in an intensive pig farming system. Although further improvements are still needed, this study is a first step in developing a pig welfare assessment protocol that combines animal-, environment-, and management-based measures.

  7. Molecular Classification Substitutes for the Prognostic Variables Stage, Age, and MYCN Status in Neuroblastoma Risk Assessment.

    PubMed

    Rosswog, Carolina; Schmidt, Rene; Oberthuer, André; Juraeva, Dilafruz; Brors, Benedikt; Engesser, Anne; Kahlert, Yvonne; Volland, Ruth; Bartenhagen, Christoph; Simon, Thorsten; Berthold, Frank; Hero, Barbara; Faldum, Andreas; Fischer, Matthias

    2017-12-01

    Current risk stratification systems for neuroblastoma patients consider clinical, histopathological, and genetic variables, and additional prognostic markers have been proposed in recent years. We here sought to select highly informative covariates in a multistep strategy based on consecutive Cox regression models, resulting in a risk score that integrates hazard ratios of prognostic variables. A cohort of 695 neuroblastoma patients was divided into a discovery set (n=75) for multigene predictor generation, a training set (n=411) for risk score development, and a validation set (n=209). Relevant prognostic variables were identified by stepwise multivariable L1-penalized least absolute shrinkage and selection operator (LASSO) Cox regression, followed by backward selection in multivariable Cox regression, and then integrated into a novel risk score. The variables stage, age, MYCN status, and two multigene predictors, NB-th24 and NB-th44, were selected as independent prognostic markers by LASSO Cox regression analysis. Following backward selection, only the multigene predictors were retained in the final model. Integration of these classifiers in a risk scoring system distinguished three patient subgroups that differed substantially in their outcome. The scoring system discriminated patients with diverging outcome in the validation cohort (5-year event-free survival, 84.9±3.4 vs 63.6±14.5 vs 31.0±5.4; P<.001), and its prognostic value was validated by multivariable analysis. We here propose a translational strategy for developing risk assessment systems based on hazard ratios of relevant prognostic variables. Our final neuroblastoma risk score comprised two multigene predictors only, supporting the notion that molecular properties of the tumor cells strongly impact clinical courses of neuroblastoma patients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  8. [Value of brain MR imaging in infants with a severe idiopathic apparent life threatening event].

    PubMed

    Christophe, C; Boutemy, R; Christiaens, F; Fonteyne, C; Ziereisen, F; Dan, B

    2000-01-01

    Prognostic value of a magnetic resonance imaging (MRI) scoring system in infants with a severe apparent life threatening event (ALTE). Ten infants with an ALTE (aged between 6 and 31 weeks) were clinically graded according to the PRISM score and evaluated with EEG, evoked potentials and MRI. The 18 MRIs obtained were distributed in 3 classes according to the delay after which they were obtained; class A (n=5): within the first 48 hours after the event, class B (n=7): between day 3 and 8 and class C (n=6): between day 9 and 50. The 18 MRIs were evaluated retrospectively using a scoring system based on 3 categories of lesions: edema, basal ganglia injury and watershed injuries. Five infants died between day 2 and day 15 after the event. The five surviving infants had follow up neurodevelopmental testing after 38 to 77 months. There was no correlation between the 5 MRIs of class A and the neurological outcome. For the MRIs of class B and C, the scoring system can be of great value when combined with the scores of EEG, EP and PRISM. The scoring system for MRI performed within 48 hours after the event is falsely reassuring. MRI can be helpful as early as 3 days after the event when combined with the score of the electrophysiological investigations and the PRISM.

  9. An illustrative overview of semi-quantitative MRI scoring of knee osteoarthritis: lessons learned from longitudinal observational studies.

    PubMed

    Roemer, F W; Hunter, D J; Crema, M D; Kwoh, C K; Ochoa-Albiztegui, E; Guermazi, A

    2016-02-01

    To introduce the most popular magnetic resonance imaging (MRI) osteoarthritis (OA) semi-quantitative (SQ) scoring systems to a broader audience with a focus on the most commonly applied scores, i.e., the MOAKS and WORMS system and illustrate similarities and differences. While the main structure and methodology of each scoring system are publicly available, the core of this overview will be an illustrative imaging atlas section including image examples from multiple OA studies applying MRI in regard to different features assessed, show specific examples of different grades and point out pitfalls and specifics of SQ assessment including artifacts, blinding to time point of acquisition and within-grade evaluation. Similarities and differences between different scoring systems are presented. Technical considerations are followed by a brief description of the most commonly utilized SQ scoring systems including their responsiveness and reliability. The second part is comprised of the atlas section presenting illustrative image examples. Evidence suggests that SQ assessment of OA by expert MRI readers is valid, reliable and responsive, which helps investigators to understand the natural history of this complex disease and to evaluate potential new drugs in OA clinical trials. Researchers have to be aware of the differences and specifics of the different systems to be able to engage in imaging assessment and interpretation of imaging-based data. SQ scoring has enabled us to explain associations of structural tissue damage with clinical manifestations of the disease and with morphological alterations thought to represent disease progression. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. An illustrative overview of semi-quantitative MRI scoring of knee osteoarthritis: Lessons learned from longitudinal observational studies

    PubMed Central

    Roemer, Frank W.; Hunter, David J.; Crema, Michel D.; Kwoh, C. Kent; Ochoa-Albiztegui, Elena; Guermazi, Ali

    2015-01-01

    Objective To introduce the most popular magnetic resonance imaging (MRI) osteoarthritis (OA) semi-quantitative (SQ) scoring systems to a broader audience with a focus on the most commonly applied scores, i.e. the MOAKS and WORMS system and illustrate similarities and differences. Design While the main structure and methodology of each scoring system are publicly available, the core of this overview will be an illustrative imaging atlas section including image examples from multiple osteoarthritis studies applying MRI in regard to different features assessed, show specific examples of different grades and point out pitfalls and specifics of SQ assessment including artifacts, blinding to time point of acquisition and within-grade evaluation. Results Similarities and differences between different scoring systems are presented. Technical considerations are followed by a brief description of the most commonly utilized SQ scoring systems including their responsiveness and reliability. The second part is comprised of the atlas section presenting illustrative image examples. Conclusions Evidence suggests that SQ assessment of OA by expert MRI readers is valid, reliable and responsive, which helps investigators to understand the natural history of this complex disease and to evaluate potential new drugs in OA clinical trials. Researchers have to be aware of the differences and specifics of the different systems to be able to engage in imaging assessment and interpretation of imaging-based data. SQ scoring has enabled us to explain associations of structural tissue damage with clinical manifestations of the disease and with morphological alterations thought to represent disease progression. PMID:26318656

  11. Effects of comprehensive educational reforms on academic success in a diverse student body.

    PubMed

    Lieberman, Steven A; Ainsworth, Michael A; Asimakis, Gregory K; Thomas, Lauree; Cain, Lisa D; Mancuso, Melodee G; Rabek, Jeffrey P; Zhang, Ni; Frye, Ann W

    2010-12-01

    Calls for medical curriculum reform and increased student diversity in the USA have seen mixed success: performance outcomes following curriculum revisions have been inconsistent and national matriculation of under-represented minority (URM) students has not met aspirations. Published innovations in curricula, academic support and pipeline programmes usually describe isolated interventions that fail to affect curriculum-level outcomes. United States Medical Licensing Examination (USMLE) Step 1 performance and graduation rates were analysed for three classes of medical students before (matriculated 1995-1997, n=517) and after (matriculated 2003-2005, n=597) implementing broad-based reforms in our education system. The changes in pipeline recruitment and preparation programmes, instructional methods, assessment systems, academic support and board preparation were based on sound educational principles and best practices. Post-reform classes were diverse with respect to ethnicity (25.8% URM students), gender (51.8% female), and Medical College Admissions Test (MCAT) score (range 20-40; 24.1% scored ≤ 25). Mean±standard deviation MCAT scores were minimally changed (from 27.2±4.7 to 27.8±3.6). The Step 1 failure rate decreased by 69.3% and mean score increased by 14.0 points (effect size: d=0.67) overall. Improvements were greater among women (failure rate decreased by 78.9%, mean score increased by 15.6 points; d=0.76) and URM students (failure rate decreased by 76.5%, mean score increased by 14.6 points; d=0.74), especially African-American students (failure rate decreased by 93.6%, mean score increased by 20.8 points; d=1.12). Step 1 scores increased across the entire MCAT range. Four- and 5-year graduation rates increased by 7.1% and 5.8%, respectively. The effect sizes in these performance improvements surpassed those previously reported for isolated interventions in curriculum and student support. This success is likely to have resulted from the broad-based, mutually reinforcing nature of reforms in multiple components of the education system. The results suggest that a narrow reductionist view of educational programme reform is less likely to result in improved educational outcomes than a system perspective that addresses the coordinated functioning of multiple aspects of the academic enterprise. © Blackwell Publishing Ltd 2010.

  12. Evaluation of inter-observer agreement when using a clinical respiratory scoring system in pre-weaned dairy calves.

    PubMed

    Buczinski, S; Faure, C; Jolivet, S; Abdallah, A

    2016-07-01

    To determine inter-observer agreement for a clinical scoring system for the detection of bovine respiratory disease complex in calves, and the impact of classification of calves as sick or healthy based on different cut-off values. Two third-year veterinary students (Observer 1 and 2) and one post-graduate student (Observer 3) received 4 hours of training on scoring dairy calves for signs of respiratory disease, including rectal temperature, cough, eye and nasal discharge, and ear position. Observers 1 and 2 scored 40 pre-weaning dairy calves 24 hours apart (80 observations) over three visits to a calf-rearing facility, and Observers 1, 2 and 3 scored 20 calves on one visit. Inter-observer agreement was assessed using percentage of agreement (PA) and Kappa statistics for individual clinical signs, comparing Observers 1 and 2. Agreement between the three observers for total clinical score was assessed using cut-off values of ≥4, ≥5 and ≥6 to indicate unhealthy calves. Inter-observer PA for rectal temperature was 0.68, for cough 0.78, for nasal discharge 0.62, for eye discharge 0.63, and for ear position 0.85. Kappa values for all clinical signs indicated slight to fair agreement (<0.4), except temperature that had moderate agreement (0.6). The Fleiss' Kappa for total score, using cut-offs of ≥4, ≥5 and ≥6 to indicate unhealthy calves, was 0.35, 0.06 and 0.13, respectively, indicating slight to fair agreement. There was important inter-observer discrepancies in scoring clinical signs of respiratory disease, using relatively inexperienced observers. These disagreements may ultimately mean increased false negative or false positive diagnoses and incorrect treatment of cases. Visual assessment of clinical signs associated with bovine respiratory disease needs to be thoroughly validated when disease monitoring is based on the use of a clinical scoring system.

  13. Rasch analysis of the Edmonton Symptom Assessment System and research implications

    PubMed Central

    Cheifetz, O.; Packham, T.L.; MacDermid, J.C.

    2014-01-01

    Background Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Methods Polytomous Rasch analysis (Andrich’s rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. Results The Rasch reliability index was 0.73, falling short of the desired 0.80–0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0–10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. Conclusions The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions. PMID:24764703

  14. On combining multi-normalization and ancillary measures for the optimal score level fusion of fingerprint and voice biometrics

    NASA Astrophysics Data System (ADS)

    Mohammed Anzar, Sharafudeen Thaha; Sathidevi, Puthumangalathu Savithri

    2014-12-01

    In this paper, we have considered the utility of multi-normalization and ancillary measures, for the optimal score level fusion of fingerprint and voice biometrics. An efficient matching score preprocessing technique based on multi-normalization is employed for improving the performance of the multimodal system, under various noise conditions. Ancillary measures derived from the feature space and the score space are used in addition to the matching score vectors, for weighing the modalities, based on their relative degradation. Reliability (dispersion) and the separability (inter-/intra-class distance and d-prime statistics) measures under various noise conditions are estimated from the individual modalities, during the training/validation stage. The `best integration weights' are then computed by algebraically combining these measures using the weighted sum rule. The computed integration weights are then optimized against the recognition accuracy using techniques such as grid search, genetic algorithm and particle swarm optimization. The experimental results show that, the proposed biometric solution leads to considerable improvement in the recognition performance even under low signal-to-noise ratio (SNR) conditions and reduces the false acceptance rate (FAR) and false rejection rate (FRR), making the system useful for security as well as forensic applications.

  15. Inflammation-based prognostic score and number of lymph node metastases are independent prognostic factors in esophageal squamous cell carcinoma.

    PubMed

    Kobayashi, Takashi; Teruya, Masanori; Kishiki, Tomokazu; Kaneko, Susumu; Endo, Daisuke; Takenaka, Yoshiharu; Miki, Kenji; Kobayashi, Kaoru; Morita, Koji

    2010-08-01

    Few studies have investigated whether the Glasgow Prognostic Score (GPS), an inflammation-based prognostic score, is useful for postoperative prognosis of esophageal squamous cell carcinoma. GPS was calculated on the basis of admission data as follows: patients with elevated C-reactive protein level (>10 mg/l) and hypoalbuminemia (<35 g/l) were assigned to GPS2. Patients with one or no abnormal value were assigned to GPS1 or GPS0. A new scoring system was constructed using independent prognostic variables and was evaluated on whether it could be used to dictate the choice of clinical options. 65 patients with esophageal squamous cell carcinoma were enrolled. GPS and the number of lymph node metastases were found to be independent prognostic variables. The scoring system comprising GPS and the number of lymph node metastases was found to be effective in the prediction of a long-term outcome (p < 0.0001). Preoperative GPS may be useful for postoperative prognosis of patients with esophageal squamous cell carcinoma. GPS and the number of lymph node metastases could be used to identify a subgroup of patients with esophageal squamous cell carcinoma who are eligible for radical resection but show poor prognosis.

  16. Quantifying Risk of Financial Incapacity and Financial Exploitation in Community-dwelling Older Adults: Utility of a Scoring System for the Lichtenberg Financial Decision-making Rating Scale.

    PubMed

    Lichtenberg, Peter A; Gross, Evan; Ficker, Lisa J

    2018-06-08

    This work examines the clinical utility of the scoring system for the Lichtenberg Financial Decision-making Rating Scale (LFDRS) and its usefulness for decision making capacity and financial exploitation. Objective 1 was to examine the clinical utility of a person centered, empirically supported, financial decision making scale. Objective 2 was to determine whether the risk-scoring system created for this rating scale is sufficiently accurate for the use of cutoff scores in cases of decisional capacity and cases of suspected financial exploitation. Objective 3 was to examine whether cognitive decline and decisional impairment predicted suspected financial exploitation. Two hundred independently living, non-demented community-dwelling older adults comprised the sample. Participants completed the rating scale and other cognitive measures. Receiver operating characteristic curves were in the good to excellent range for decisional capacity scoring, and in the fair to good range for financial exploitation. Analyses supported the conceptual link between decision making deficits and risk for exploitation, and supported the use of the risk-scoring system in a community-based population. This study adds to the empirical evidence supporting the use of the rating scale as a clinical tool assessing risk for financial decisional impairment and/or financial exploitation.

  17. A scoring system for ascertainment of incident stroke; the Risk Index Score (RISc).

    PubMed

    Kass-Hout, T A; Moyé, L A; Smith, M A; Morgenstern, L B

    2006-01-01

    The main objective of this study was to develop and validate a computer-based statistical algorithm that could be translated into a simple scoring system in order to ascertain incident stroke cases using hospital admission medical records data. The Risk Index Score (RISc) algorithm was developed using data collected prospectively by the Brain Attack Surveillance in Corpus Christi (BASIC) project, 2000. The validity of RISc was evaluated by estimating the concordance of scoring system stroke ascertainment to stroke ascertainment by physician and/or abstractor review of hospital admission records. RISc was developed on 1718 randomly selected patients (training set) and then statistically validated on an independent sample of 858 patients (validation set). A multivariable logistic model was used to develop RISc and subsequently evaluated by goodness-of-fit and receiver operating characteristic (ROC) analyses. The higher the value of RISc, the higher the patient's risk of potential stroke. The study showed RISc was well calibrated and discriminated those who had potential stroke from those that did not on initial screening. In this study we developed and validated a rapid, easy, efficient, and accurate method to ascertain incident stroke cases from routine hospital admission records for epidemiologic investigations. Validation of this scoring system was achieved statistically; however, clinical validation in a community hospital setting is warranted.

  18. Scoring system for differentiating perforated and non-perforated pediatric appendicitis.

    PubMed

    Blumfield, Einat; Yang, Daniel; Grossman, Joshua

    2017-10-01

    Appendicitis is the most common indication for emergency pediatric surgery and its most significant complication is perforation. Perforated appendicitis (PA) may be managed conservatively, whereas non-perforated appendicitis (NP) is managed surgically. Recent studies have shown that ultrasound (US) is effective for differentiating between PA and NP, and does not expose pediatric patients to ionizing radiation. The purpose of this study is to enhance the accuracy of differentiation with a novel scoring system based on clinical, laboratory, and US findings. This retrospective study included 243 patients aged 2-17 years who presented between 2006 and 2013 with surgically proven appendicitis, of whom 60 had perforation. Clinical and laboratory data were collected and US images evaluated by a pediatric radiologist. To create the scoring system, point values were assigned to each parameter. A randomly selected training sample of 137 subjects was used to create a scoring prediction model. The model was tested on the remaining 106 patients. Scores of ≥6, ≥11, and ≥15 yielded specificities of 64, 91, and 99%, and sensitivities of 96, 61, and 29%, respectively (p < 0.001). We have designed a scoring system incorporating clinical, laboratory, and sonographic findings which can differentiate PA from NP with high specificity.

  19. Evolution of biological sequences implies an extreme value distribution of type I for both global and local pairwise alignment scores.

    PubMed

    Bastien, Olivier; Maréchal, Eric

    2008-08-07

    Confidence in pairwise alignments of biological sequences, obtained by various methods such as Blast or Smith-Waterman, is critical for automatic analyses of genomic data. Two statistical models have been proposed. In the asymptotic limit of long sequences, the Karlin-Altschul model is based on the computation of a P-value, assuming that the number of high scoring matching regions above a threshold is Poisson distributed. Alternatively, the Lipman-Pearson model is based on the computation of a Z-value from a random score distribution obtained by a Monte-Carlo simulation. Z-values allow the deduction of an upper bound of the P-value (1/Z-value2) following the TULIP theorem. Simulations of Z-value distribution is known to fit with a Gumbel law. This remarkable property was not demonstrated and had no obvious biological support. We built a model of evolution of sequences based on aging, as meant in Reliability Theory, using the fact that the amount of information shared between an initial sequence and the sequences in its lineage (i.e., mutual information in Information Theory) is a decreasing function of time. This quantity is simply measured by a sequence alignment score. In systems aging, the failure rate is related to the systems longevity. The system can be a machine with structured components, or a living entity or population. "Reliability" refers to the ability to operate properly according to a standard. Here, the "reliability" of a sequence refers to the ability to conserve a sufficient functional level at the folded and maturated protein level (positive selection pressure). Homologous sequences were considered as systems 1) having a high redundancy of information reflected by the magnitude of their alignment scores, 2) which components are the amino acids that can independently be damaged by random DNA mutations. From these assumptions, we deduced that information shared at each amino acid position evolved with a constant rate, corresponding to the information hazard rate, and that pairwise sequence alignment scores should follow a Gumbel distribution, which parameters could find some theoretical rationale. In particular, one parameter corresponds to the information hazard rate. Extreme value distribution of alignment scores, assessed from high scoring segments pairs following the Karlin-Altschul model, can also be deduced from the Reliability Theory applied to molecular sequences. It reflects the redundancy of information between homologous sequences, under functional conservative pressure. This model also provides a link between concepts of biological sequence analysis and of systems biology.

  20. From scores to face templates: a model-based approach.

    PubMed

    Mohanty, Pranab; Sarkar, Sudeep; Kasturi, Rangachar

    2007-12-01

    Regeneration of templates from match scores has security and privacy implications related to any biometric authentication system. We propose a novel paradigm to reconstruct face templates from match scores using a linear approach. It proceeds by first modeling the behavior of the given face recognition algorithm by an affine transformation. The goal of the modeling is to approximate the distances computed by a face recognition algorithm between two faces by distances between points, representing these faces, in an affine space. Given this space, templates from an independent image set (break-in) are matched only once with the enrolled template of the targeted subject and match scores are recorded. These scores are then used to embed the targeted subject in the approximating affine (non-orthogonal) space. Given the coordinates of the targeted subject in the affine space, the original template of the targeted subject is reconstructed using the inverse of the affine transformation. We demonstrate our ideas using three, fundamentally different, face recognition algorithms: Principal Component Analysis (PCA) with Mahalanobis cosine distance measure, Bayesian intra-extrapersonal classifier (BIC), and a feature-based commercial algorithm. To demonstrate the independence of the break-in set with the gallery set, we select face templates from two different databases: Face Recognition Grand Challenge (FRGC) and Facial Recognition Technology (FERET) Database (FERET). With an operational point set at 1 percent False Acceptance Rate (FAR) and 99 percent True Acceptance Rate (TAR) for 1,196 enrollments (FERET gallery), we show that at most 600 attempts (score computations) are required to achieve a 73 percent chance of breaking in as a randomly chosen target subject for the commercial face recognition system. With similar operational set up, we achieve a 72 percent and 100 percent chance of breaking in for the Bayesian and PCA based face recognition systems, respectively. With three different levels of score quantization, we achieve 69 percent, 68 percent and 49 percent probability of break-in, indicating the robustness of our proposed scheme to score quantization. We also show that the proposed reconstruction scheme has 47 percent more probability of breaking in as a randomly chosen target subject for the commercial system as compared to a hill climbing approach with the same number of attempts. Given that the proposed template reconstruction method uses distinct face templates to reconstruct faces, this work exposes a more severe form of vulnerability than a hill climbing kind of attack where incrementally different versions of the same face are used. Also, the ability of the proposed approach to reconstruct actual face templates of the users increases privacy concerns in biometric systems.

  1. A nutrient profiling assessment of packaged foods using two star-based front-of-pack labels.

    PubMed

    Carrad, Amy M; Louie, Jimmy Chun Yu; Yeatman, Heather R; Dunford, Elizabeth K; Neal, Bruce C; Flood, Victoria M

    2016-08-01

    To compare two front-of-pack nutrition labelling systems for the assessment of packaged foods and drinks with Australian Dietary Guidelines. A cross-sectional nutrient profiling assessment. Food and drink products (n 20 225) were categorised into scoring levels using criteria for the Institute of Medicine (IOM) three-star system and the five-star Australian Health Star Rating (HSR). The effectiveness of these systems to categorise foods in accordance with Australian Dietary Guidelines was explored. The study was conducted in Australia, using a comprehensive food database. Packaged food and drink products (n 20 225) available in Australia. Using the IOM three-star system, the majority (55 %) of products scored the minimum 0 points and 25·5 % scored the maximum 3 points. Using HSR criteria, the greatest proportion of products (15·2 %) scored three-and-a-half stars from a possible five and 12·5 % received the lowest rating of a half-star. Very few products (4·1 %) scored five stars. Products considered core foods and drinks in Australian Dietary Guidelines received higher scores than discretionary foods in all food categories for both labelling systems (all P<0·05; Mann-Whitney U test), with the exception of fish products using IOM three-star criteria (P=0·603). The largest discrepancies in median score between the two systems were for the food categories edible oils, convenience foods and dairy. Both the IOM three-star and Australian HSR front-of-pack labelling systems rated packaged foods and drinks broadly in line with Australian Dietary Guidelines by assigning core foods higher ratings and discretionary foods lower ratings.

  2. Tailored balance exercises on people with multiple sclerosis: A pilot randomized, controlled study.

    PubMed

    Brichetto, Giampaolo; Piccardo, Elisa; Pedullà, Ludovico; Battaglia, Mario Alberto; Tacchino, Andrea

    2015-07-01

    Altered integration of signals from visual (VIS), somatosensory (PROP) and vestibular system (VEST) lead to balance control impairments affecting the daily living activities of patients with multiple sclerosis (PwMS). As a consequence, tailored interventions could be crucial in improving efficacy of balance rehabilitation treatments. The objective of this paper is to assess the efficacy of tailored rehabilitation treatments for balance disorders based on visual, somatosensory and vestibular deficits versus traditional rehabilitation exercises. Thirty-two PwMS were assessed with the Berg Balance Scale (BBS), the composite score (CS) obtained by computerized dynamic posturography (CDP) test and the Modified Fatigue Impact Scale (MFIS). Based on CDP analysis, prevalent VIS, PROP or VEST deficits were identified and patients randomly allocated to a personalized (PRG) or traditional (TRG) rehabilitation group. BBS score showed a significant difference between pre- and post-treatment scores of 6.3 and 2.0 points respectively for PRG and TRG. CS showed a significant difference between pre- and post-treatment scores of 16.6 and 7.6 points respectively for PRG and TRG. No interaction effect was found for MFIS score. BBS and CS showed changes in the PRG group that met clinical relevant difference, underlining that tailored rehabilitation interventions based on patient-specific sensory system impairment could improve balance and postural control in PwMS. © The Author(s), 2015.

  3. Integrating knowledge based functionality in commercial hospital information systems.

    PubMed

    Müller, M L; Ganslandt, T; Eich, H P; Lang, K; Ohmann, C; Prokosch, H U

    2000-01-01

    Successful integration of knowledge-based functions in the electronic patient record depends on direct and context-sensitive accessibility and availability to clinicians and must suit their workflow. In this paper we describe an exemplary integration of an existing standalone scoring system for acute abdominal pain into two different commercial hospital information systems using Java/Corba technolgy.

  4. Prediction of drug synergy in cancer using ensemble-based machine learning techniques

    NASA Astrophysics Data System (ADS)

    Singh, Harpreet; Rana, Prashant Singh; Singh, Urvinder

    2018-04-01

    Drug synergy prediction plays a significant role in the medical field for inhibiting specific cancer agents. It can be developed as a pre-processing tool for therapeutic successes. Examination of different drug-drug interaction can be done by drug synergy score. It needs efficient regression-based machine learning approaches to minimize the prediction errors. Numerous machine learning techniques such as neural networks, support vector machines, random forests, LASSO, Elastic Nets, etc., have been used in the past to realize requirement as mentioned above. However, these techniques individually do not provide significant accuracy in drug synergy score. Therefore, the primary objective of this paper is to design a neuro-fuzzy-based ensembling approach. To achieve this, nine well-known machine learning techniques have been implemented by considering the drug synergy data. Based on the accuracy of each model, four techniques with high accuracy are selected to develop ensemble-based machine learning model. These models are Random forest, Fuzzy Rules Using Genetic Cooperative-Competitive Learning method (GFS.GCCL), Adaptive-Network-Based Fuzzy Inference System (ANFIS) and Dynamic Evolving Neural-Fuzzy Inference System method (DENFIS). Ensembling is achieved by evaluating the biased weighted aggregation (i.e. adding more weights to the model with a higher prediction score) of predicted data by selected models. The proposed and existing machine learning techniques have been evaluated on drug synergy score data. The comparative analysis reveals that the proposed method outperforms others in terms of accuracy, root mean square error and coefficient of correlation.

  5. Promoting students' conceptual understanding using STEM-based e-book

    NASA Astrophysics Data System (ADS)

    Komarudin, U.; Rustaman, N. Y.; Hasanah, L.

    2017-05-01

    This study aims to examine the effect of Science, Technology, Engineering, and Mathematics (STEM) based e-book in promoting students'conceptual understanding on lever system in human body. The E-book used was the e-book published by National Ministry of Science Education. The research was conducted by a quasi experimental with pretest and posttest design. The subjects consist of two classes of 8th grade junior high school in Pangkalpinang, Indonesia, which were devided into experimental group (n=34) and control group (n=32). The students in experimental group was taught by STEM-based e-book, while the control group learned by non STEM-based e-book. The data was collected by an instrument pretest and postest. Pretest and posttest scored, thenanalyzed using descriptive statistics and independent t-test. The result of independent sample t-test shows that no significant differenceson students' pretest score between control and experimental group. However, there were significant differences on students posttest score and N-gain score between control and experimental group with sig = 0.000(p<0.005). N-gain analysis showsthe higher performance of students who were participated in experimental group (mean = 66.03) higher compared to control group (mean = 47.66) in answering conceptual understanding questions. Based on the results, it can be concluded that STEM-based e-book has positiveimpact in promoting students' understanding on lever system in human body. Therefore this learning approach is potential to be used as an alternative to triger the enhancement of students' understanding in science.

  6. Evaluation and application of multiple scoring functions for a virtual screening experiment

    NASA Astrophysics Data System (ADS)

    Xing, Li; Hodgkin, Edward; Liu, Qian; Sedlock, David

    2004-05-01

    In order to identify novel chemical classes of factor Xa inhibitors, five scoring functions (FlexX, DOCK, GOLD, ChemScore and PMF) were engaged to evaluate the multiple docking poses generated by FlexX. The compound collection was composed of confirmed potent factor Xa inhibitors and a subset of the LeadQuest® screening compound library. Except for PMF the other four scoring functions succeeded in reproducing the crystal complex (PDB code: 1FAX). During virtual screening the highest hit rate (80%) was demonstrated by FlexX at an energy cutoff of -40 kJ/mol, which is about 40-fold over random screening (2.06%). Limited results suggest that presenting more poses of a single molecule to the scoring functions could deteriorate their enrichment factors. A series of promising scaffolds with favorable binding scores was retrieved from LeadQuest. Consensus scoring by pair-wise intersection failed to enrich the hit rate yielded by single scorings (i.e. FlexX). We note that reported successes of consensus scoring in hit rate enrichment could be artificial because their comparisons were based on a selected subset of single scoring and a markedly reduced subset of double or triple scoring. The findings presented in this report are based upon a single biological system and support further studies.

  7. A procedure for linking psychosocial job characteristics data to health surveys.

    PubMed Central

    Schwartz, J E; Pieper, C F; Karasek, R A

    1988-01-01

    A system is presented for linking information about psychosocial characteristics of job situations to national health surveys. Job information can be imputed to individuals on surveys that contain three-digit US Census occupation codes. Occupational mean scores on psychosocial job characteristics-control over task situation (decision latitude), psychological work load, physical exertion, and other measures-for the linkage system are derived from US national surveys of working conditions (Quality of Employment Surveys 1969, 1972, and 1977). This paper discusses a new method for reducing the biases in multivariate analyses that are likely to arise when utilizing linkage systems based on mean scores. Such biases are reduced by modifying the linkage system to adjust imputed individual scores for demographic factors such as age, education, race, marital status and, implicitly, sex (since men and women have separate linkage data bases). Statistics on the linkage system's efficiency and reliability are reported. All dimensions have high inter-survey reproducibility. Despite their psychosocial nature, decision latitude and physical exertion can be more efficiently imputed with the linkage system than earnings (a non-psychosocial job characteristic). The linkage system presented here is a useful tool for initial epidemiological studies of the consequences of psychosocial job characteristics and constitutes the methodological basis for the subsequent paper. PMID:3389426

  8. Multilingual Data Selection for Low Resource Speech Recognition

    DTIC Science & Technology

    2016-09-12

    Figure 1: Identification of language clusters using scores from an LID system training languages used in the Base and OP1 evaluation periods of the Babel...the posterior scores over frames. For a set of languages that are used to train the lan- guage identification (LID) network, pairs of languages that...which are combined during test time to produce 10 dimensional language 3854 Figure 3: Identification of language clusters using scores from individually

  9. Development of a seaweed species-selection index for successful culture in a seaweed-based integrated aquaculture system

    NASA Astrophysics Data System (ADS)

    Kang, Yun Hee; Hwang, Jae Ran; Chung, Ik Kyo; Park, Sang Rul

    2013-03-01

    Integrated multi-trophic aquaculture (IMTA) has been proposed as a concept that combines the cultivation of fed aquaculture species ( e.g., finfish/shrimp) with extractive aquaculture species ( e.g., shellfish/seaweed). In seaweed-based integrated aquaculture, seaweeds have the capacity to reduce the environmental impact of nitrogen-rich effluents on coastal ecosystems. Thus, selection of optimal species for such aquaculture is of great importance. The present study aimed to develop a seaweed species-selection index for selecting suitable species in seaweed-based integrated aquaculture system. The index was synthesized using available literature-based information, reference data, and physiological seaweed experiments to identify and prioritize the desired species. Undaria pinnatifida, Porphyra yezoensis and Ulva compressa scored the highest according to a seaweed-based integrated aquaculture suitability index (SASI). Seaweed species with the highest scores were adjudged to fit the integrated aquaculture systems. Despite the application of this model limited by local aquaculture environment, it is considered to be a useful tool for selecting seaweed species in IMTA.

  10. Developing a cumulative anatomic scoring system for military perineal and pelvic blast injuries.

    PubMed

    Mossadegh, Somayyeh; Midwinter, M; Parker, P

    2013-03-01

    Improvised explosive device (IED) yields in Afghanistan have increased resulting in more proximal injuries. The injury severity score (ISS) is an anatomic aggregate score of the three most severely injured anatomical areas but does not accurately predict severity in IED related pelvi-perineal trauma patients. A scoring system based on abbreviated injury score (AIS) was developed to reflect the severity of these injuries in order to better understand risk factors, develop a tool for future audit and improve performance. Using standard AIS descriptors, injury scales were constructed for the pelvis (1, minor to 6, maximal). The perineum was divided into anterior and posterior zones as relevant to injury patterns and blast direction with each soft tissue structure being allocated a score from its own severity scale. A cumulative score, from 1 to 36 for soft tissue, or a maximum of 42 if a pelvic fracture was involved, was created for all structures injured in the anterior and posterior zones. Using this new scoring system, 77% of patients survived with a pelvi-perineal trauma score (PPTS) below 5. There was a significant increase in mortality, number of pelvic fractures and amputations with increase in score when comparing the first group (score 1-5) to the second group (score 6-10). For scores between 6 and 16 survival was 42% and 22% for scores between 17 and 21. In our cohort of 62 survivors, 1 patient with an IED related pelvi-perineal injury had a 'theoretically un-survivable' maximal ISS of 75 and survived, whereas there were no survivors with a PPTS greater than 22 but this group had no-one with an ISS of 75 suggesting ISS is not an accurate reflection of the true severity of pelvi-perineal blast injury. This scoring system is the initial part of a more complex logistic regression model that will contribute towards a unique trauma scoring system to aid surgical teams in predicting fluid requirements and operative timelines. In austere environments, it may also help to prevent futile resuscitations. Better correlation between measurement of severity and outcome would aid performance improvement monitoring. In the longer term it will also allow benchmarking of current survival rates and comparisons in the future.

  11. Left behind by Design: Proficiency Counts and Test-Based Accountability. Working Paper

    ERIC Educational Resources Information Center

    Neal, Derek; Schanzenbach, Diane Whitmore

    2009-01-01

    Many test-based accountability systems, including the No Child Left Behind Act of 2001 (NCLB), place great weight on the numbers of students who score at or above specified proficiency levels in various subjects. Accountability systems based on these metrics often provide incentives for teachers and principals to target children near current…

  12. Left behind By Design: Proficiency Counts and Test-Based Accountability. NBER Working Paper No. 13293

    ERIC Educational Resources Information Center

    Neal, Derek; Schanzenbach, Diane Whitmore

    2007-01-01

    Many test-based accountability systems, including the No Child Left Behind Act of 2001 (NCLB), place great weight on the numbers of students who score at or above specified proficiency levels in various subjects. Accountability systems based on these metrics often provide incentives for teachers and principals to target children near current…

  13. Face recognition system using multiple face model of hybrid Fourier feature under uncontrolled illumination variation.

    PubMed

    Hwang, Wonjun; Wang, Haitao; Kim, Hyunwoo; Kee, Seok-Cheol; Kim, Junmo

    2011-04-01

    The authors present a robust face recognition system for large-scale data sets taken under uncontrolled illumination variations. The proposed face recognition system consists of a novel illumination-insensitive preprocessing method, a hybrid Fourier-based facial feature extraction, and a score fusion scheme. First, in the preprocessing stage, a face image is transformed into an illumination-insensitive image, called an "integral normalized gradient image," by normalizing and integrating the smoothed gradients of a facial image. Then, for feature extraction of complementary classifiers, multiple face models based upon hybrid Fourier features are applied. The hybrid Fourier features are extracted from different Fourier domains in different frequency bandwidths, and then each feature is individually classified by linear discriminant analysis. In addition, multiple face models are generated by plural normalized face images that have different eye distances. Finally, to combine scores from multiple complementary classifiers, a log likelihood ratio-based score fusion scheme is applied. The proposed system using the face recognition grand challenge (FRGC) experimental protocols is evaluated; FRGC is a large available data set. Experimental results on the FRGC version 2.0 data sets have shown that the proposed method shows an average of 81.49% verification rate on 2-D face images under various environmental variations such as illumination changes, expression changes, and time elapses.

  14. A method for modelling GP practice level deprivation scores using GIS

    PubMed Central

    Strong, Mark; Maheswaran, Ravi; Pearson, Tim; Fryers, Paul

    2007-01-01

    Background A measure of general practice level socioeconomic deprivation can be used to explore the association between deprivation and other practice characteristics. An area-based categorisation is commonly chosen as the basis for such a deprivation measure. Ideally a practice population-weighted area-based deprivation score would be calculated using individual level spatially referenced data. However, these data are often unavailable. One approach is to link the practice postcode to an area-based deprivation score, but this method has limitations. This study aimed to develop a Geographical Information Systems (GIS) based model that could better predict a practice population-weighted deprivation score in the absence of patient level data than simple practice postcode linkage. Results We calculated predicted practice level Index of Multiple Deprivation (IMD) 2004 deprivation scores using two methods that did not require patient level data. Firstly we linked the practice postcode to an IMD 2004 score, and secondly we used a GIS model derived using data from Rotherham, UK. We compared our two sets of predicted scores to "gold standard" practice population-weighted scores for practices in Doncaster, Havering and Warrington. Overall, the practice postcode linkage method overestimated "gold standard" IMD scores by 2.54 points (95% CI 0.94, 4.14), whereas our modelling method showed no such bias (mean difference 0.36, 95% CI -0.30, 1.02). The postcode-linked method systematically underestimated the gold standard score in less deprived areas, and overestimated it in more deprived areas. Our modelling method showed a small underestimation in scores at higher levels of deprivation in Havering, but showed no bias in Doncaster or Warrington. The postcode-linked method showed more variability when predicting scores than did the GIS modelling method. Conclusion A GIS based model can be used to predict a practice population-weighted area-based deprivation measure in the absence of patient level data. Our modelled measure generally had better agreement with the population-weighted measure than did a postcode-linked measure. Our model may also avoid an underestimation of IMD scores in less deprived areas, and overestimation of scores in more deprived areas, seen when using postcode linked scores. The proposed method may be of use to researchers who do not have access to patient level spatially referenced data. PMID:17822545

  15. The evaluation of acute physiology and chronic health evaluation II score, poisoning severity score, sequential organ failure assessment score combine with lactate to assess the prognosis of the patients with acute organophosphate pesticide poisoning.

    PubMed

    Yuan, Shaoxin; Gao, Yusong; Ji, Wenqing; Song, Junshuai; Mei, Xue

    2018-05-01

    The aim of this study was to assess the ability of acute physiology and chronic health evaluation II (APACHE II) score, poisoning severity score (PSS) as well as sequential organ failure assessment (SOFA) score combining with lactate (Lac) to predict mortality in the Emergency Department (ED) patients who were poisoned with organophosphate.A retrospective review of 59 stands-compliant patients was carried out. Receiver operating characteristic (ROC) curves were constructed based on the APACHE II score, PSS, SOFA score with or without Lac, respectively, and the areas under the ROC curve (AUCs) were determined to assess predictive value. According to SOFA-Lac (a combination of SOFA and Lac) classification standard, acute organophosphate pesticide poisoning (AOPP) patients were divided into low-risk and high-risk groups. Then mortality rates were compared between risk levels.Between survivors and non-survivors, there were significant differences in the APACHE II score, PSS, SOFA score, and Lac (all P < .05). The AUCs of the APACHE II score, PSS, and SOFA score were 0.876, 0.811, and 0.837, respectively. However, after combining with Lac, the AUCs were 0.922, 0.878, and 0.956, respectively. According to SOFA-Lac, the mortality of high-risk group was significantly higher than low-risk group (P < .05) and the patients of the non-survival group were all at high risk.These data suggest the APACHE II score, PSS, SOFA score can all predict the prognosis of AOPP patients. For its simplicity and objectivity, the SOFA score is a superior predictor. Lac significantly improved the predictive abilities of the 3 scoring systems, especially for the SOFA score. The SOFA-Lac system effectively distinguished the high-risk group from the low-risk group. Therefore, the SOFA-Lac system is significantly better at predicting mortality in AOPP patients.

  16. [Validation of two indices of biological integrity (IBI) for the Angulo River subbasin in Central Mexico].

    PubMed

    Ramírez-Herrejón, Juan Pablo; Mercado-Silva, Norman; Medina-Nava, Martina; Domínguez-Domínguez, Omar

    2012-12-01

    Efforts to halt freshwater ecosystem degradation in central Mexico can benefit from using bio-monitoring tools that reflect the condition of their biotic integrity. We analyzed the applicability of two fish-based indices of biotic integrity using data from lotic and lentic systems in the Angulo River subbasin (Lerma-Chapala basin). Both independent data from our own collections during two consecutive years, and existing information detailing the ecological attributes of each species, were used to calculate indices of biological integrity for 16 sites in lotic and lentic habitats. We assessed environmental quality by combining independent evaluations water and habitat quality for each site. We found sites with poor, regular and good biotic integrity. Our study did not find sites with good environmental quality. Fish-based IBI scores were strongly and significantly correlated with scores from independent environmental assessment techniques. IBI scores were adequate at representing environmental conditions in most study sites. These results expand the area where a lotic system fish-based IBI can be used, and constitute an initial validation of a lentic system fish-based IBI. Our results suggest that these bio-monitoring tools can be used in future conservation efforts in freshwater ecosystems in the Middle Lerma Basin.

  17. Research and Development of an Advanced Personal Load Carriage System Phases 2 and 3. Section C: Analysis of Seven Pack-Based Systems Using Human FAST Trials

    DTIC Science & Technology

    1997-10-30

    3.0 2.9 3.8 Physical comfort 4.1 4.5 2.4 2.4 3.1 Thermal comfort 4.8 5.0 3.0 3.2 4.0 Scores greater than 5 (box) were considered superior. Scores...2.4 3.2 Thermal comfort 3.0 3.4 3.2 2.3 Scores greater than 5 (box) were considered superior. Scores 3.5 or less (grey) were considered inferior...1.2 0.4 0.8 -0.3 Mobility -0.4 -1.7 -0.1 0.8 0.4 Physical comfort -0.5 -1.2 0.2 0.3 0.3 Thermal comfort -1.7 -2.5 -0.2 -0.1 -1.4 Differences

  18. Prognostic scores in oesophageal or gastric variceal bleeding.

    PubMed

    Ohmann, C; Stöltzing, H; Wins, L; Busch, E; Thon, K

    1990-05-01

    Numerous scoring systems have been developed for the prediction of outcome of variceal bleeding; however, only a few have been evaluated adequately. The object of this study was to improve the classical Child-Pugh score (CPS) and to test other scores from the literature. Patients (n = 82) with endoscopically confirmed variceal bleeding and long-term sclerotherapy were included in the study. Linear logistic regression (LR) was applied to different sets of prognostic variables with regard to 30-day mortality. In addition, scores from the literature were evaluated on the data set. Performance was measured by the accuracy and receiver-operating characteristic curves. The application of LR to all five CPS variables (accuracy, 80%) was superior to the classical CPS (70%). LR with selection from the CPS variables or from other sets of variables resulted in no improvement. Compared with CPS only three scores from the literature, mainly based on subsets of the CPS variables, showed an improved accuracy. It is concluded that CPS is still a good scoring system; however, it can be improved by statistical analysis using the same variables.

  19. Utility of the CPS+EG staging system in hormone receptor-positive, human epidermal growth factor receptor 2-negative breast cancer treated with neoadjuvant chemotherapy.

    PubMed

    Marmé, Frederik; Lederer, Bianca; Blohmer, Jens-Uwe; Costa, Serban Dan; Denkert, Carsten; Eidtmann, Holger; Gerber, Bernd; Hanusch, Claus; Hilfrich, Jörn; Huober, Jens; Jackisch, Christian; Kümmel, Sherko; Loibl, Sibylle; Paepke, Stefan; Untch, Michael; von Minckwitz, Gunter; Schneeweiss, Andreas

    2016-01-01

    Pathologic complete response after neoadjuvant chemotherapy (NACT) correlates with overall survival (OS) in primary breast cancer. A recently described staging system based on pre-treatment clinical stage (CS), final pathological stage (PS), estrogen receptor (ER) status and nuclear grade (NG) leads to a refined estimation of prognosis in unselected patients. Its performance in luminal type breast cancers has not been determined. This study investigates the clinical utility of this CPS+EG score when restricted to hormone receptor-positive (HR+)/human epidermal growth factor receptor 2-negative (HER2-) patients and compares the results to a cohort of unselected patients. The CPS+EG score was calculated for 6637 unselected patients and 2454 patients with HR+/HER2- tumours who received anthracycline/taxane-based NACT within 8 prospective German trials. Five-year disease-free survival (DFS) and OS were 75.6% and 84.1% for the unselected cohort and 80.6% and 87.8% for the HR+/HER2- subgroup, respectively. The CPS+EG system distinguished different prognostic groups with 5-year DFS ranging from 0% to 91%. The CPS+EG system leads to an improved categorisation of patients by outcome compared to CS, PS, ER or NG alone. When applying the CPS+EG score to the HR+/HER2- subgroup, a shift to lower scores was observed compared to the overall population, but 5-year DFS and OS for the individual scores were identical to that observed in the overall population. In HR+/HER2- patients, the CPS+EG staging system retains its ability to facilitate a refined stratification of patients according to outcome. It can help to select candidates for post-neoadjuvant clinical trials in luminal breast cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Development and validation of an individual dietary index based on the British Food Standard Agency nutrient profiling system in a French context.

    PubMed

    Julia, Chantal; Touvier, Mathilde; Méjean, Caroline; Ducrot, Pauline; Péneau, Sandrine; Hercberg, Serge; Kesse-Guyot, Emmanuelle

    2014-12-01

    Nutrient profiling systems could be useful public health tools as a basis for front-of-package nutrition labeling, advertising regulations, or food taxes. However, their ability beyond characterization of foods to adequately characterize individual diets necessitates further investigation. The objectives of this study were 1) to calculate a score at the individual level based on the British Food Standard Agency (FSA) food-level nutrient profiling system of each food consumed, and 2) to evaluate the validity of the resulting diet-quality score against food group consumption, nutrient intake, and sociodemographic and lifestyle variables. A representative sample of the French population was selected from the NutriNet-Santé Study (n = 4225). Dietary data were collected through repeated 24-h dietary records. Sociodemographic and lifestyle data were self-reported. All foods consumed were characterized by their FSA nutrient profile, and the energy intake from each food consumed was used to compute FSA-derived aggregated scores at the individual level. A score of adherence to French nutritional recommendations [Programme National Nutrition Santé guideline score (PNNS-GS)] was computed as a comparison diet-quality score. Associations between food consumption, nutritional indicators, lifestyle and sociodemographic variables, and quartiles of aggregated scores were investigated using ANOVAs and linear regression models. Participants with more favorable scores consumed higher amounts of fruits [difference Δ = 156 g/d between quartile 1 (less favorable) and quartile 4 (most favorable), P < 0.001], vegetables (Δ = 85 g/d, P < 0.001), and fish, and lower amounts of snack foods (Δ = -72 g/d, P < 0.001 for sugary snacks); they also had higher vitamin and mineral intakes and lower intakes of saturated fat. Participants with more favorable scores also had a higher adherence to nutritional recommendations measured with the PNNS-GS (Δ = 2.13 points, P < 0.001). Women, older subjects, and higher-income subjects were more likely to have more favorable scores. Our results show adequate validity of the FSA nutrient profiling system to characterize individual diets in a French context. The NutriNet-Santé Study was registered in the European Clinical Trials Database (EudraCT) as 2013-000929-31. © 2014 American Society for Nutrition.

  1. A coupled duration-focused architecture for real-time music-to-score alignment.

    PubMed

    Cont, Arshia

    2010-06-01

    The capacity for real-time synchronization and coordination is a common ability among trained musicians performing a music score that presents an interesting challenge for machine intelligence. Compared to speech recognition, which has influenced many music information retrieval systems, music's temporal dynamics and complexity pose challenging problems to common approximations regarding time modeling of data streams. In this paper, we propose a design for a real-time music-to-score alignment system. Given a live recording of a musician playing a music score, the system is capable of following the musician in real time within the score and decoding the tempo (or pace) of its performance. The proposed design features two coupled audio and tempo agents within a unique probabilistic inference framework that adaptively updates its parameters based on the real-time context. Online decoding is achieved through the collaboration of the coupled agents in a Hidden Hybrid Markov/semi-Markov framework, where prediction feedback of one agent affects the behavior of the other. We perform evaluations for both real-time alignment and the proposed temporal model. An implementation of the presented system has been widely used in real concert situations worldwide and the readers are encouraged to access the actual system and experiment the results.

  2. Development and Application of a Plant-Based Diet Scoring System for Japanese Patients with Inflammatory Bowel Disease

    PubMed Central

    Chiba, Mitsuro; Nakane, Kunio; Takayama, Yuko; Sugawara, Kae; Ohno, Hideo; Ishii, Hajime; Tsuda, Satoko; Tsuji, Tsuyotoshi; Komatsu, Masafumi; Sugawara, Takeshi

    2016-01-01

    Context Plant-based diets (PBDs) are a healthy alternative to westernized diets. A semivegetarian diet, a PBD, has been shown to prevent a relapse in Crohn disease. However, there is no way to measure adherence to PBDs. Objective To develop a simple way of evaluating adherence to a PBD for Japanese patients with inflammatory bowel disease (IBD). Design PBD scores were assigned according to the frequency of consumption provided on a food-frequency questionnaire, obtained on hospitalization for 159 patients with ulcerative colitis and 70 patients with Crohn disease. Eight items considered to be preventive factors for IBD were scored positively, and 8 items considered to be IBD risk factors were scored negatively. The PBD score was calculated from the sum of plus and minus scores. Higher PBD scores indicated greater adherence to a PBD. The PBD scores were evaluated on hospitalization and 2 years after discharge for 22 patients with Crohn disease whose dietary pattern and prognosis were established. Main Outcome Measure Plant-Based Diet score. Results The PBD scores differed significantly, in descending order, by dietary type: pro-Japanese diet, mixed type, and pro-westernized diet (Wilcoxon/Kruskal-Wallis test). The PBD scores in the ulcerative colitis and Crohn disease groups were 10.9 ± 9.5 and 8.2 ± 8.2, respectively. For patients with Crohn disease, those with long-term remission and normal C-reactive protein concentration were significantly more likely to have PBD scores of 25 or greater than below 25 (χ2). Conclusion The PBD score is a valid assessment of PBD dietary adherence. PMID:27768566

  3. Automated scoring system of standard uptake value for torso FDG-PET images

    NASA Astrophysics Data System (ADS)

    Hara, Takeshi; Kobayashi, Tatsunori; Kawai, Kazunao; Zhou, Xiangrong; Itoh, Satoshi; Katafuchi, Tetsuro; Fujita, Hiroshi

    2008-03-01

    The purpose of this work was to develop an automated method to calculate the score of SUV for torso region on FDG-PET scans. The three dimensional distributions for the mean and the standard deviation values of SUV were stored in each volume to score the SUV in corresponding pixel position within unknown scans. The modeling methods is based on SPM approach using correction technique of Euler characteristic and Resel (Resolution element). We employed 197 nor-mal cases (male: 143, female: 54) to assemble the normal metabolism distribution of FDG. The physique were registered each other in a rectangular parallelepiped shape using affine transformation and Thin-Plate-Spline technique. The regions of the three organs were determined based on semi-automated procedure. Seventy-three abnormal spots were used to estimate the effectiveness of the scoring methods. As a result, the score images correctly represented that the scores for normal cases were between zeros to plus/minus 2 SD. Most of the scores of abnormal spots associated with cancer were lager than the upper of the SUV interval of normal organs.

  4. Assessing the performance of MM/PBSA and MM/GBSA methods. 8. Predicting binding free energies and poses of protein-RNA complexes.

    PubMed

    Chen, Fu; Sun, Huiyong; Wang, Junmei; Zhu, Feng; Liu, Hui; Wang, Zhe; Lei, Tailong; Li, Youyong; Hou, Tingjun

    2018-06-21

    Molecular docking provides a computationally efficient way to predict the atomic structural details of protein-RNA interactions (PRI), but accurate prediction of the three-dimensional structures and binding affinities for PRI is still notoriously difficult, partly due to the unreliability of the existing scoring functions for PRI. MM/PBSA and MM/GBSA are more theoretically rigorous than most scoring functions for protein-RNA docking, but their prediction performance for protein-RNA systems remains unclear. Here, we systemically evaluated the capability of MM/PBSA and MM/GBSA to predict the binding affinities and recognize the near-native binding structures for protein-RNA systems with different solvent models and interior dielectric constants (ϵ in ). For predicting the binding affinities, the predictions given by MM/GBSA based on the minimized structures in explicit solvent and the GBGBn1 model with ϵ in = 2 yielded the highest correlation with the experimental data. Moreover, the MM/GBSA calculations based on the minimized structures in implicit solvent and the GBGBn1 model distinguished the near-native binding structures within the top 10 decoys for 118 out of the 149 protein-RNA systems (79.2%). This performance is better than all docking scoring functions studied here. Therefore, the MM/GBSA rescoring is an efficient way to improve the prediction capability of scoring functions for protein-RNA systems. Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  5. Measures of Partial Knowledge and Unexpected Responses in Multiple-Choice Tests

    ERIC Educational Resources Information Center

    Chang, Shao-Hua; Lin, Pei-Chun; Lin, Zih-Chuan

    2007-01-01

    This study investigates differences in the partial scoring performance of examinees in elimination testing and conventional dichotomous scoring of multiple-choice tests implemented on a computer-based system. Elimination testing that uses the same set of multiple-choice items rewards examinees with partial knowledge over those who are simply…

  6. 77 FR 47707 - Public Housing Assessment System (PHAS): Physical Condition Scoring Notice and Revised Dictionary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... Standards (UPCS) inspection protocol was designed to be a uniform inspection process and standard for HUD's... frequency of inspections based on the results the UPCS inspection. UPCS was designed to assess the condition... physical assessment score. HUD Response: The UPCS inspection protocol as designed assesses the physical...

  7. Monitoring the Performance of Human and Automated Scores for Spoken Responses

    ERIC Educational Resources Information Center

    Wang, Zhen; Zechner, Klaus; Sun, Yu

    2018-01-01

    As automated scoring systems for spoken responses are increasingly used in language assessments, testing organizations need to analyze their performance, as compared to human raters, across several dimensions, for example, on individual items or based on subgroups of test takers. In addition, there is a need in testing organizations to establish…

  8. Introducing a balanced scorecard management system in a university anesthesiology department.

    PubMed

    Zbinden, Alex M

    2002-12-01

    The study goal was to show how Balanced Scorecard, a modern management tool based on score numbers, can efficiently be applied to a university anesthesiology department. Nineteen score numbers were established in four perspectives. Meaningful results were obtained with limited resources to support a process of innovation and improvement.

  9. Assessing Text-Based Writing of Low-Skilled College Students

    ERIC Educational Resources Information Center

    Perin, Dolores; Lauterbach, Mark

    2018-01-01

    The problem of poor writing skills at the postsecondary level is a large and troubling one. This study investigated the writing skills of low-skilled adults attending college developmental education courses by determining whether variables from an automated scoring system were predictive of human scores on writing quality rubrics. The human-scored…

  10. Web-Based Education Prior to Outpatient Orthopaedic Surgery Enhances Early Patient Satisfaction Scores: A Prospective Randomized Controlled Study.

    PubMed

    van Eck, Carola F; Toor, Aneet; Banffy, Michael B; Gambardella, Ralph A

    2018-01-01

    A good patient-surgeon relationship relies on adequate preoperative education and counseling. Several multimedia resources, such as web-based education tools, have become available to enhance aspects of perioperative care. The purpose of this study was to evaluate the effect of an interactive web-based education tool on perioperative patient satisfaction scores after outpatient orthopaedic surgery. It was hypothesized that web-based education prior to outpatient orthopaedic surgery enhances patient satisfaction scores. Randomized controlled trial; Level of evidence, 1. All patients undergoing knee arthroscopy with meniscectomy, chondroplasty, or anterior cruciate ligament reconstruction or shoulder arthroscopy with rotator cuff repair were eligible for inclusion and were randomized to the study or control group. The control group received routine education by the surgeon, whereas the study group received additional web-based education. At the first postoperative visit, all patients completed the OAS CAHPS (Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems) survey. Differences in patient satisfaction scores between the study and control groups were determined with an independent t test. A total of 177 patients were included (104 [59%] males; mean age, 42 ± 14 years); 87 (49%) patients were randomized to receive additional web-based education. Total patient satisfaction score was significantly higher in the study group (97 ± 5) as compared with the control group (94 ± 8; P = .019), specifically for the OAS CAHPS core measure "recovery" (92 ± 13 vs 82 ± 23; P = .001). Age, sex, race, workers' compensation status, education level, overall health, emotional health, procedure type and complexity, and addition of a video did not influence patient satisfaction scores. Supplemental web-based patient education prior to outpatient orthopaedic surgery enhances patient satisfaction scores.

  11. Systematic Review of Plant-Based Homeopathic Basic Research: An Update.

    PubMed

    Ücker, Annekathrin; Baumgartner, Stephan; Sokol, Anezka; Huber, Roman; Doesburg, Paul; Jäger, Tim

    2018-05-01

     Plant-based test systems have been described as a useful tool for investigating possible effects of homeopathic preparations. The last reviews of this research field were published in 2009/2011. Due to recent developments in the field, an update is warranted. Publications on plant-based test systems were analysed with regard to publication quality, reproducibility and potential for further research.  A literature search was conducted in online databases and specific journals, including publications from 2008 to 2017 dealing with plant-based test systems in homeopathic basic research. To be included, they had to contain statistical analysis and fulfil quality criteria according to a pre-defined manuscript information score (MIS). Publications scoring at least 5 points (maximum 10 points) were assumed to be adequate. They were analysed for the use of adequate controls, outcome and reproducibility.  Seventy-four publications on plant-based test systems were found. Thirty-nine publications were either abstracts or proceedings of conferences and were excluded. From the remaining 35 publications, 26 reached a score of 5 or higher in the MIS. Adequate controls were used in 13 of these publications. All of them described specific effects of homeopathic preparations. The publication quality still varied: a substantial number of publications (23%) did not adequately document the methods used. Four reported on replication trials. One replication trial found effects of homeopathic preparations comparable to the original study. Three replication trials failed to confirm the original study but identified possible external influencing factors. Five publications described novel plant-based test systems. Eight trials used systematic negative control experiments to document test system stability.  Regarding research design, future trials should implement adequate controls to identify specific effects of homeopathic preparations and include systematic negative control experiments. Further external and internal replication trials, and control of influencing factors, are needed to verify results. Standardised test systems should be developed. The Faculty of Homeopathy.

  12. Development and reliability of a multi-modality scoring system for evaluation of disease progression in pre-clinical models of osteoarthritis: celecoxib may possess disease-modifying properties.

    PubMed

    Panahifar, A; Jaremko, J L; Tessier, A G; Lambert, R G; Maksymowych, W P; Fallone, B G; Doschak, M R

    2014-10-01

    We sought to develop a comprehensive scoring system for evaluation of pre-clinical models of osteoarthritis (OA) progression, and use this to evaluate two different classes of drugs for management of OA. Post-traumatic OA (PTOA) was surgically induced in skeletally mature rats. Rats were randomly divided in three groups receiving either glucosamine (high dose of 192 mg/kg) or celecoxib (clinical dose) or no treatment. Disease progression was monitored utilizing micro-magnetic resonance imaging (MRI), micro-computed tomography (CT) and histology. Pertinent features such as osteophytes, subchondral sclerosis, joint effusion, bone marrow lesion (BML), cysts, loose bodies and cartilage abnormalities were included in designing a sensitive multi-modality based scoring system, termed the rat arthritis knee scoring system (RAKSS). Overall, an inter-observer correlation coefficient (ICC) of greater than 0.750 was achieved for each scored feature. None of the treatments prevented cartilage loss, synovitis, joint effusion, or sclerosis. However, celecoxib significantly reduced osteophyte development compared to placebo. Although signs of inflammation such as synovitis and joint effusion were readily identified at 4 weeks post-operation, we did not detect any BML. We report the development of a sensitive and reliable multi-modality scoring system, the RAKSS, for evaluation of OA severity in pre-clinical animal models. Using this scoring system, we found that celecoxib prevented enlargement of osteophytes in this animal model of PTOA, and thus it may be useful in preventing OA progression. However, it did not show any chondroprotective effect using the recommended dose. In contrast, high dose glucosamine had no measurable effects. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  13. The colostomy impact score: development and validation of a patient reported outcome measure for rectal cancer patients with a permanent colostomy. A population-based study.

    PubMed

    Thyø, A; Emmertsen, K J; Pinkney, T D; Christensen, P; Laurberg, S

    2017-01-01

    The aim was to develop and validate a simple scoring system evaluating the impact of colostomy dysfunction on quality of life (QOL) in patients with a permanent stoma after rectal cancer treatment. In this population-based study, 610 patients with a permanent colostomy after previous rectal cancer treatment during the period 2001-2007 completed two questionnaires: (i) the basic stoma questionnaire consisting of 22 items about stoma function with one anchor question addressing the overall stoma impact on QOL and (ii) the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ) C30. Answers from half of the cohort were used to develop the score and subsequently validated on the remaining half. Logistic regression analyses identified and selected items for the score and multivariate analysis established the score value allocated to each item. The colostomy impact score includes seven items with a total range from 0 to 38 points. A score of ≥ 10 indicates major colostomy impact (Major CI). The score has a sensitivity of 85.7% for detecting patients with significant stoma impact on QOL. Using the EORTC QLQ scales, patients with Major CI experienced significant impairment in their QOL compared to the Minor CI group. This new scoring system appears valid for the assessment of the impact on QOL from having a permanent colostomy in a Danish rectal cancer population. It requires validation in non-Danish populations prior to its acceptance as a valuable patient-reported outcome measure for patients internationally. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  14. Evaluation of APRI and FIB-4 scoring systems for non-invasive assessment of hepatic fibrosis in chronic hepatitis B patients.

    PubMed

    Kim, W Ray; Berg, Thomas; Asselah, Tarik; Flisiak, Robert; Fung, Scott; Gordon, Stuart C; Janssen, Harry L A; Lampertico, Pietro; Lau, Daryl; Bornstein, Jeffrey D; Schall, Raul E Aguilar; Dinh, Phillip; Yee, Leland J; Martins, Eduardo B; Lim, Seng Gee; Loomba, Rohit; Petersen, Jörg; Buti, Maria; Marcellin, Patrick

    2016-04-01

    While the gold standard in the assessment of liver fibrosis remains liver biopsy, non-invasive methods have been increasingly used for chronic hepatitis B (CHB). This study aimed to evaluate the performance of two commonly used non-invasive scoring systems (aspartate aminotransferase-to-platelet ratio index (APRI) and fibrosis index based on four factors (FIB-4)) to predict fibrosis stage in CHB patients. Demographic, histologic and clinical laboratory data from two trials investigating tenofovir disoproxil fumarate in CHB were analyzed. Predicted fibrosis stage, based on established scales and cut-off values for APRI and FIB-4 scores, was compared with Ishak scores obtained from liver biopsy at baseline and at 240 week follow-up. In the 575 patients with a baseline liver biopsy, APRI and FIB-4 scores correlated with Ishak stage (p<0.01); however extensive overlap in the distribution of both scores across Ishak stages prevented accurate determination of fibrosis. The majority (81-89%) of patients with advanced fibrosis or cirrhosis were missed by the scores. Similarly, 71% patients without fibrosis were misclassified as having clinically significant fibrosis. APRI and FIB-4 scores at week 240 tended to be low and underestimate fibrosis stage in the patients with liver biopsies after 240 weeks of therapy. APRI or FIB-4 reduction did not correlate with fibrosis regression after 240 weeks of antiviral therapy. APRI and FIB-4 scores are not suitable for use in clinical practice in CHB patients for assessment of hepatic fibrosis according to Ishak stage, especially in gauging improvements in liver fibrosis following therapy. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  15. A simple weighted scoring system to guide surgical decision-making in patients with parapneumonic pleural effusion.

    PubMed

    Chang, Che-Chia; Chen, Tzu-Ping; Yeh, Chi-Hsiao; Huang, Pin-Fu; Wang, Yao-Chang; Yin, Shun-Ying

    2016-11-01

    The selection of ideal candidates for surgical intervention among patients with parapneumonic pleural effusion remains challenging. In this retrospective study, we sought to identify the main predictors of surgical treatment and devise a simple scoring system to guide surgical decision-making. Between 2005 and 2014, we identified 276 patients with parapneumonic pleural effusion. Patients in the training set (n=201) were divided into two groups according to their treatment modality (non-surgery vs. surgery). Using multivariable logistic regression analysis, we devised a scoring system to guide surgical decision-making. The score was subsequently validated in an independent set of 75 patients. A white blood cell count >13,500/µL, pleuritic pain, loculations, and split pleura sign were identified as independent predictors of surgical treatment. A weighted score based on these factors was devised, as follows: white blood cell count >13,500/µL (one point), pleuritic pain (one point), loculations (two points), and split pleura sign (three points). A score >4 was associated with a surgical approach with a sensitivity of 93.4%, a specificity of 82.4%, and an area under curve (AUC) of 0.879 (95% confidence interval: 0.828-0.930). In the validation set, a sensitivity of 94.3% and a specificity of 79.6% were found (AUC=0.869). The proposed scoring system reliably identifies patients with parapneumonic pleural effusion who are candidates for surgery. Pending independent external validation, our score may inform the appropriate use of surgical interventions in this clinical setting.

  16. The role of marshall and rotterdam score in predicting 30-day outcome of traumatic brain injury

    NASA Astrophysics Data System (ADS)

    Siahaan, A. M. P.; Akbar, T. Y. M.; Nasution, M. D.

    2018-03-01

    Traumatic brain injury (TBI) remains one of the leading causes of mortality and morbidity, especially in the young population. To predict the outcome of TBI, Marshall, and Rotterdam–CT Scan based scoring was mostly used. As many studies showed conflicting results regarding of the usage of both scoring, this study aims to determine the correlation between Rotterdam and Marshall scoring system with outcome in 30 days and found correlation among them. In 120 subjects with TBI that admitted to Adam Malik General Hospital, we found a significant association of both scorings with the 30-day Glasgow Outcome Score. Therefore, we recommend the use of Marshall and Rotterdam CT Score in initial assessment as a good predictor for patients with TBI.

  17. Performance Status and Change--Measuring Education System Effectiveness with Data from PISA 2000-2009

    ERIC Educational Resources Information Center

    Lenkeit, Jenny; Caro, Daniel H.

    2014-01-01

    Reports of international large-scale assessments tend to evaluate and compare education system performance based on absolute scores. And policymakers refer to high-performing and economically prosperous education systems to enhance their own systemic features. But socioeconomic differences between systems compromise the plausibility of those…

  18. Management of heart failure in the new era: the role of scores.

    PubMed

    Mantegazza, Valentina; Badagliacca, Roberto; Nodari, Savina; Parati, Gianfranco; Lombardi, Carolina; Di Somma, Salvatore; Carluccio, Erberto; Dini, Frank Lloyd; Correale, Michele; Magrì, Damiano; Agostoni, Piergiuseppe

    2016-08-01

    Heart failure is a widespread syndrome involving several organs, still characterized by high mortality and morbidity, and whose clinical course is heterogeneous and hardly predictable.In this scenario, the assessment of heart failure prognosis represents a fundamental step in clinical practice. A single parameter is always unable to provide a very precise prognosis. Therefore, risk scores based on multiple parameters have been introduced, but their clinical utility is still modest. In this review, we evaluated several prognostic models for acute, right, chronic, and end-stage heart failure based on multiple parameters. In particular, for chronic heart failure we considered risk scores essentially based on clinical evaluation, comorbidities analysis, baroreflex sensitivity, heart rate variability, sleep disorders, laboratory tests, echocardiographic imaging, and cardiopulmonary exercise test parameters. What is at present established is that a single parameter is not sufficient for an accurate prediction of prognosis in heart failure because of the complex nature of the disease. However, none of the scoring systems available is widely used, being in some cases complex, not user-friendly, or based on expensive or not easily available parameters. We believe that multiparametric scores for risk assessment in heart failure are promising but their widespread use needs to be experienced.

  19. Nurse-led epistaxis management within the emergency department.

    PubMed

    Hakim, Navid; Mummadi, Sangha Mitra; Jolly, Karan; Dawson, Julian; Darr, Adnan

    2018-01-11

    the incidence of epistaxis has increased secondary to increased life expectancy and morbidities. This study sought to assess the knowledge, practice and opinion relating to adequacy of training of advanced nurse practitioners (ANPs) and staff nurses (SNs) in the emergency department. a national survey was distributed over an 8-week period; this included a 3-point scoring system based on the National Institute for Health and Care Excellence Clinical Knowledge Summaries guidance on epistaxis management to assess overall performance. analysis included 109 ANPs and 101 SNs; 12% of ANPs achieved the maximum score, 40% scored 2, 25% scored 1, and 23% scored 0, while 14% of SNs achieved the maximum score, 24% scored 2, 29% scored 1, and 32% scored 0. Overall 88% of respondents advocated further training. significant deficits in knowledge regarding epistaxis management were highlighted. Further training could help to empower patients in basic first aid measures, subsequently reducing admissions rates.

  20. Evaluation of interobserver variability and diagnostic performance of developed MRI-based radiological scoring system for invasive placenta previa.

    PubMed

    Ueno, Yoshiko; Maeda, Tetsuo; Tanaka, Utaru; Tanimura, Kenji; Kitajima, Kazuhiro; Suenaga, Yuko; Takahashi, Satoru; Yamada, Hideto; Sugimura, Kazuro

    2016-09-01

    To evaluate the interobserver variability and diagnostic performance of a developed magnetic resonance imaging (MRI)-based scoring system for invasive placenta previa. Prenatal MR images of 70 women were retrospectively evaluated, 18 of whom were diagnosed with invasive placenta. The six MR features (dark band on T2 -weighted images, intraplacental abnormal vascularity, placental bulge, heterogeneous placenta, myometrial thinning, and placental protrusion sign) were scored on 5-point Likert scale separately, and the cumulative radiological score (CRS) was defined as the sum of each score. Two more experienced radiologists (readers A and B) and two less experienced residents (readers C and D) calculated the CRS. Interobserver variability was assessed by measuring the intraclass correlation coefficient. Diagnostic performance was evaluated by means of receiver operating characteristic (ROC) analysis. Interobserver variability for CRS was excellent for the more experienced radiologists (0.85), and good for all readers (0.72) and the less experienced residents (0.66). The area under the ROC curve (Az) and accuracy (Acc) for CRS were significantly higher or equivalent to those of other MR features for all readers (Az and Acc for reader A; CRS, 0.92, 91.4%; intraplacental T2 dark band, 0.83, P = 0.009, 81.4%, P = 0.03; intraplacental abnormal vascularity, 0.9, P = 0.3, 90.0%, P = 1.00; placental bulge, 0.81, P = 0.0008, 80.0%, P = 0.02; heterogeneous placenta, 0.85, P = 0.11, 74.3%, P = 0.002; myometrial thinning, 0.84, P = 0.06, 60.0%, P < 0.0001; placental protrusion sign, 0.81, P = 0.01, 81.4%, P = 0.26). This developed MRI-based scoring system demonstrated excellent or good interobserver variability, and good diagnostic performance for invasive placenta previa. J. Magn. Reson. Imaging 2016;44:573-583. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Statistical analysis to assess automated level of suspicion scoring methods in breast ultrasound

    NASA Astrophysics Data System (ADS)

    Galperin, Michael

    2003-05-01

    A well-defined rule-based system has been developed for scoring 0-5 the Level of Suspicion (LOS) based on qualitative lexicon describing the ultrasound appearance of breast lesion. The purposes of the research are to asses and select one of the automated LOS scoring quantitative methods developed during preliminary studies in benign biopsies reduction. The study has used Computer Aided Imaging System (CAIS) to improve the uniformity and accuracy of applying the LOS scheme by automatically detecting, analyzing and comparing breast masses. The overall goal is to reduce biopsies on the masses with lower levels of suspicion, rather that increasing the accuracy of diagnosis of cancers (will require biopsy anyway). On complex cysts and fibroadenoma cases experienced radiologists were up to 50% less certain in true negatives than CAIS. Full correlation analysis was applied to determine which of the proposed LOS quantification methods serves CAIS accuracy the best. This paper presents current results of applying statistical analysis for automated LOS scoring quantification for breast masses with known biopsy results. It was found that First Order Ranking method yielded most the accurate results. The CAIS system (Image Companion, Data Companion software) is developed by Almen Laboratories and was used to achieve the results.

  2. Predicting the need for massive transfusion in trauma patients: the Traumatic Bleeding Severity Score.

    PubMed

    Ogura, Takayuki; Nakamura, Yoshihiko; Nakano, Minoru; Izawa, Yoshimitsu; Nakamura, Mitsunobu; Fujizuka, Kenji; Suzukawa, Masayuki; Lefor, Alan T

    2014-05-01

    The ability to easily predict the need for massive transfusion may improve the process of care, allowing early mobilization of resources. There are currently no clear criteria to activate massive transfusion in severely injured trauma patients. The aims of this study were to create a scoring system to predict the need for massive transfusion and then to validate this scoring system. We reviewed the records of 119 severely injured trauma patients and identified massive transfusion predictors using statistical methods. Each predictor was converted into a simple score based on the odds ratio in a multivariate logistic regression analysis. The Traumatic Bleeding Severity Score (TBSS) was defined as the sum of the component scores. The predictive value of the TBSS for massive transfusion was then validated, using data from 113 severely injured trauma patients. Receiver operating characteristic curve analysis was performed to compare the results of TBSS with the Trauma-Associated Severe Hemorrhage score and the Assessment of Blood Consumption score. In the development phase, five predictors of massive transfusion were identified, including age, systolic blood pressure, the Focused Assessment with Sonography for Trauma scan, severity of pelvic fracture, and lactate level. The maximum TBSS is 57 points. In the validation study, the average TBSS in patients who received massive transfusion was significantly greater (24.2 [6.7]) than the score of patients who did not (6.2 [4.7]) (p < 0.01). The area under the receiver operating characteristic curve, sensitivity, and specificity for a TBSS greater than 15 points was 0.985 (significantly higher than the other scoring systems evaluated at 0.892 and 0.813, respectively), 97.4%, and 96.2%, respectively. The TBSS is simple to calculate using an available iOS application and is accurate in predicting the need for massive transfusion. Additional multicenter studies are needed to further validate this scoring system and further assess its utility. Prognostic study, level III.

  3. PQScal (Power Quality Score Calculation for Distribution Systems with DER Integration)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power Quality is of great importance to evaluate the “health” of a distribution system, especially when the distributed energy resource (DER) penetration becomes more significant. The individual components that make up power quality, such as voltage magnitude and unbalance, can be measured in simulations or in the field, however, a comprehensive method to incorporate all of these values into a single score doesn't exist. As a result, we propose a methodology to quantify the power quality health using the single number value, named as Power Quality Score (PQS). The PQS is dependent on six metrics that are developed based onmore » both components that directly impact power quality and those are often reference in the context of power quality. These six metrics are named as System Average Voltage Magnitude Violation Index (SAVMVI), System Average Voltage Fluctuation Index (SAVFI), System Average Voltage Unbalance Index (SAVUI), System Control Device Operation Index (SCDOI), System Reactive Power Demand Index (SRPDI) and System Energy Loss Index (SELI). This software tool, PQScal, is developed based on this novel PQS methodology. Besides of traditional distribution systems, PQScal can also measure the power quality for distribution systems with various DER penetrations. PQScal has been tested on two utility distribution feeders with distinct model characteristics and its effectiveness has been proved. In sum, PQScal can help utilities or other parties to measure the power quality of distribution systems with DER integration easily and effectively.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bekelman, Justin E., E-mail: bekelman@uphs.upenn.edu; Department of Medical Ethics and Health Policy, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania; Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, Pennsylvania

    Purpose: To present the principles and rationale of the Proton Priority System (PROPS), a priority points framework that assigns higher scores to patients thought to more likely benefit from proton therapy, and the distribution of PROPS scores by patient characteristics Methods and Materials: We performed multivariable logistic regression to evaluate the association between PROPS scores and receipt of proton therapy, adjusted for insurance status, gender, race, geography, and the domains that inform the PROPS score. Results: Among 1529 adult patients considered for proton therapy prioritization during our Center's ramp-up phase of treatment availability, PROPS scores varied by age, diagnosis, site,more » and other PROPS domains. In adjusted analyses, receipt of proton therapy was lower for patients with non-Medicare relative to Medicare health insurance (commercial vs Medicare: adjusted odds ratio [OR] 0.47, 95% confidence interval [CI] 0.34-0.64; managed care vs Medicare: OR 0.40, 95% CI 0.28-0.56; Medicaid vs Medicare: OR 0.24, 95% CI 0.13-0.44). Proton Priority System score and age were not significantly associated with receipt of proton therapy. Conclusions: The Proton Priority System is a rationally designed and transparent system for allocation of proton therapy slots based on the best available evidence and expert opinion. Because the actual allocation of treatment slots depends mostly on insurance status, payers may consider incorporating PROPS, or its underlying principles, into proton therapy coverage policies.« less

  5. The Role of Scoring Systems and Urine Dipstick in Prediction of Rhabdomyolysis-induced Acute Kidney Injury: a Systematic Review.

    PubMed

    Safari, Saeed; Yousefifard, Mahmoud; Hashemi, Behrooz; Baratloo, Alireza; Forouzanfar, Mohammad Mehdi; Rahmati, Farhad; Motamedi, Maryam; Najafi, Iraj

    2016-05-01

    During the past decade, using serum biomarkers and clinical decision rules for early prediction of rhabdomyolysis-induced acute kidney injury (AKI) has received much attention from researchers. This study aimed to broadly review the value of scoring systems and urine dipstick in prediction of rhabdomyolysis-induced AKI. The study was designed based on the guidelines of the Meta-analysis of Observational Studies in Epidemiology statement. Search was done in electronic databases of MEDLINE, EMBASE, Cochrane Library, Scopus, and Google Scholar by 2 independent reviewers. Studies evaluating AKI risk factors in rhabdomyolysis patients with the aim of developing a scoring model as well as those assessing the role of urine dipstick in these patients were included. Of the 5997 articles found, 143 were potentially relevant studies. After studying their full texts, 6 articles were entered into the systematic review. Two studies had developed or validated scoring systems of the "rule of thumb," and the AKI index, and the Mangled Extremity Severity Score. Four studies were on the predictive value of urine dipstick in risk prediction of rhabdomyolysis-induced AKI, with favorable results. The findings of this systematic review showed that based on the available resources, using the prediction rules and urine dipstick could be considered as valuable screening tools for detection of patients at risk for AKI following rhabdomyolysis. Yet, the external validity of the mentioned tools should be assessed before their general application in routine practice.

  6. Acid-base alterations in heatstroke.

    PubMed

    Bouchama, A; De Vol, E B

    2001-04-01

    To analyze the acid-base balance during heatstroke. Retrospective study. Heatstroke Center, Makkah, Saudi Arabia. Hundred nine consecutive heatstroke patients (mean age 55 +/- 12 years) with rectal temperature from 40 to 43.4 degrees C following exposure to hot weather. Arterial blood gases collected prospectively and analyzed using 95% confidence limits established by controlled experimental studies. Severity of heatstroke on admission assessed by Simplified Acute Physiology Score and Organ System Failure score. Metabolic acidosis was the predominant acid-base change followed by respiratory alkalosis (81 and 55% of the patients, respectively). The prevalence of metabolic acidosis (but not respiratory alkalosis) was significantly associated with the degree of hyperthermia: 63, 95 and 100% at 41, 42 and 43 degrees C, respectively (p < 0.0001). Patients with metabolic acidosis had a large anion gap (24 +/- 5). Arterial partial pressure of oxygen (PaO2), systolic blood pressure and Organ System Failure score were similar with or without metabolic acidosis. Although the acute physiology score was higher in patients with, than without, metabolic acidosis (15.7 +/- 3.7 vs 9.8 +/- 4.4, p < 0.001), there was no significant difference in neurologic morbidity and mortality (7.9 vs 1.1%, 5.6 vs 0%, p = 0.776 and 0.581, respectively). We conclude that metabolic acidosis is the predominant response in heatstroke.

  7. Monte Carlo simulation of expert judgments on human errors in chemical analysis--a case study of ICP-MS.

    PubMed

    Kuselman, Ilya; Pennecchi, Francesca; Epstein, Malka; Fajgelj, Ales; Ellison, Stephen L R

    2014-12-01

    Monte Carlo simulation of expert judgments on human errors in a chemical analysis was used for determination of distributions of the error quantification scores (scores of likelihood and severity, and scores of effectiveness of a laboratory quality system in prevention of the errors). The simulation was based on modeling of an expert behavior: confident, reasonably doubting and irresolute expert judgments were taken into account by means of different probability mass functions (pmfs). As a case study, 36 scenarios of human errors which may occur in elemental analysis of geological samples by ICP-MS were examined. Characteristics of the score distributions for three pmfs of an expert behavior were compared. Variability of the scores, as standard deviation of the simulated score values from the distribution mean, was used for assessment of the score robustness. A range of the score values, calculated directly from elicited data and simulated by a Monte Carlo method for different pmfs, was also discussed from the robustness point of view. It was shown that robustness of the scores, obtained in the case study, can be assessed as satisfactory for the quality risk management and improvement of a laboratory quality system against human errors. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Cloud-Based Service Information System for Evaluating Quality of Life after Breast Cancer Surgery.

    PubMed

    Kao, Hao-Yun; Wu, Wen-Hsiung; Liang, Tyng-Yeu; Lee, King-The; Hou, Ming-Feng; Shi, Hon-Yi

    2015-01-01

    Although recent studies have improved understanding of quality of life (QOL) outcomes of breast conserving surgery, few have used longitudinal data for more than two time points, and few have examined predictors of QOL over two years. Additionally, the longitudinal data analyses in such studies rarely apply the appropriate statistical methodology to control for censoring and inter-correlations arising from repeated measures obtained from the same patient pool. This study evaluated an internet-based system for measuring longitudinal changes in QOL and developed a cloud-based system for managing patients after breast conserving surgery. This prospective study analyzed 657 breast cancer patients treated at three tertiary academic hospitals. Related hospital personnel such as surgeons and other healthcare professionals were also interviewed to determine the requirements for an effective cloud-based system for surveying QOL in breast cancer patients. All patients completed the SF-36, Quality of Life Questionnaire (QLQ-C30) and its supplementary breast cancer measure (QLQ-BR23) at baseline, 6 months, 1 year, and 2 years postoperatively. The 95% confidence intervals for differences in responsiveness estimates were derived by bootstrap estimation. Scores derived by these instruments were interpreted by generalized estimating equation before and after surgery. All breast cancer surgery patients had significantly improved QLQ-C30 and QLQ-BR23 subscale scores throughout the 2-year follow-up period (p<0.05). During the study period, QOL generally had a negative association with advanced age, high Charlson comorbidity index score, tumor stage III or IV, previous chemotherapy, and long post-operative LOS. Conversely, QOL was positively associated with previous radiotherapy and hormone therapy. Additionally, patients with high scores for preoperative QOL tended to have high scores for QLQ-C30, QLQ-BR23 and SF-36 subscales. Based on the results of usability testing, the five constructs were rated on a Likert scale from 1-7 as follows: system usefulness (5.6±1.8), ease of use (5.6±1.5), information quality (5.4±1.4), interface quality (5.5±1.4), and overall satisfaction (5.5±1.6). The current trend in clinical medicine is applying therapies and interventions that improve QOL. Therefore, a potentially vast amount of internet-based QOL data is available for use in defining patient populations that may benefit from therapeutic intervention. Additionally, before undergoing breast conserving surgery, patients should be advised that their postoperative QOL depends not only on the success of the surgery, but also on their preoperative functional status.

  9. Cloud-Based Service Information System for Evaluating Quality of Life after Breast Cancer Surgery

    PubMed Central

    Kao, Hao-Yun; Wu, Wen-Hsiung; Liang, Tyng-Yeu; Lee, King-The; Hou, Ming-Feng; Shi, Hon-Yi

    2015-01-01

    Objective Although recent studies have improved understanding of quality of life (QOL) outcomes of breast conserving surgery, few have used longitudinal data for more than two time points, and few have examined predictors of QOL over two years. Additionally, the longitudinal data analyses in such studies rarely apply the appropriate statistical methodology to control for censoring and inter-correlations arising from repeated measures obtained from the same patient pool. This study evaluated an internet-based system for measuring longitudinal changes in QOL and developed a cloud-based system for managing patients after breast conserving surgery. Methods This prospective study analyzed 657 breast cancer patients treated at three tertiary academic hospitals. Related hospital personnel such as surgeons and other healthcare professionals were also interviewed to determine the requirements for an effective cloud-based system for surveying QOL in breast cancer patients. All patients completed the SF-36, Quality of Life Questionnaire (QLQ-C30) and its supplementary breast cancer measure (QLQ-BR23) at baseline, 6 months, 1 year, and 2 years postoperatively. The 95% confidence intervals for differences in responsiveness estimates were derived by bootstrap estimation. Scores derived by these instruments were interpreted by generalized estimating equation before and after surgery. Results All breast cancer surgery patients had significantly improved QLQ-C30 and QLQ-BR23 subscale scores throughout the 2-year follow-up period (p<0.05). During the study period, QOL generally had a negative association with advanced age, high Charlson comorbidity index score, tumor stage III or IV, previous chemotherapy, and long post-operative LOS. Conversely, QOL was positively associated with previous radiotherapy and hormone therapy. Additionally, patients with high scores for preoperative QOL tended to have high scores for QLQ-C30, QLQ-BR23 and SF-36 subscales. Based on the results of usability testing, the five constructs were rated on a Likert scale from 1–7 as follows: system usefulness (5.6±1.8), ease of use (5.6±1.5), information quality (5.4±1.4), interface quality (5.5±1.4), and overall satisfaction (5.5±1.6). Conclusions The current trend in clinical medicine is applying therapies and interventions that improve QOL. Therefore, a potentially vast amount of internet-based QOL data is available for use in defining patient populations that may benefit from therapeutic intervention. Additionally, before undergoing breast conserving surgery, patients should be advised that their postoperative QOL depends not only on the success of the surgery, but also on their preoperative functional status. PMID:26422018

  10. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group

    PubMed Central

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H.; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A. N.; Lübbert, Michael; Greenberg, Peter L.; Bennett, John M.; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L.; Ohyashiki, Kazuma; Le Beau, Michelle M.; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R.; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-01-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%–20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34+) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34+ peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34+ blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). PMID:25344522

  11. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies.

    PubMed

    Panzer, Stephanie; Mc Coy, Mark R; Hitzl, Wolfgang; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zink, Albert R; Augat, Peter

    2015-01-01

    The purpose of this study was to develop a checklist for standardized assessment of soft tissue preservation in human mummies based on whole-body computed tomography examinations, and to add a scoring system to facilitate quantitative comparison of mummies. Computed tomography examinations of 23 mummies from the Capuchin Catacombs of Palermo, Sicily (17 adults, 6 children; 17 anthropogenically and 6 naturally mummified) and 7 mummies from the crypt of the Dominican Church of the Holy Spirit of Vilnius, Lithuania (5 adults, 2 children; all naturally mummified) were used to develop the checklist following previously published guidelines. The scoring system was developed by assigning equal scores for checkpoints with equivalent quality. The checklist was evaluated by intra- and inter-observer reliability. The finalized checklist was applied to compare the groups of anthropogenically and naturally mummified bodies. The finalized checklist contains 97 checkpoints and was divided into two main categories, "A. Soft Tissues of Head and Musculoskeletal System" and "B. Organs and Organ Systems", each including various subcategories. The complete checklist had an intra-observer reliability of 98% and an inter-observer reliability of 93%. Statistical comparison revealed significantly higher values in anthropogenically compared to naturally mummified bodies for the total score and for three subcategories. In conclusion, the developed checklist allows for a standardized assessment and documentation of soft tissue preservation in whole-body computed tomography examinations of human mummies. The scoring system facilitates a quantitative comparison of the soft tissue preservation status between single mummies or mummy collections.

  12. Enhancing Retrieval with Hyperlinks: A General Model Based on Propositional Argumentation Systems.

    ERIC Educational Resources Information Center

    Picard, Justin; Savoy, Jacques

    2003-01-01

    Discusses the use of hyperlinks for improving information retrieval on the World Wide Web and proposes a general model for using hyperlinks based on Probabilistic Argumentation Systems. Topics include propositional logic, knowledge, and uncertainty; assumptions; using hyperlinks to modify document score and rank; and estimating the popularity of a…

  13. Effects of an Intelligent Web-Based English Instruction System on Students' Academic Performance

    ERIC Educational Resources Information Center

    Jia, J.; Chen, Y.; Ding, Z.; Bai, Y.; Yang, B.; Li, M.; Qi, J.

    2013-01-01

    This research conducted quasi-experiments in four middle schools to evaluate the long-term effects of an intelligent web-based English instruction system, Computer Simulation in Educational Communication (CSIEC), on students' academic attainment. The analysis of regular examination scores and vocabulary test validates the positive impact of CSIEC,…

  14. Forecasting the value of credit scoring

    NASA Astrophysics Data System (ADS)

    Saad, Shakila; Ahmad, Noryati; Jaffar, Maheran Mohd

    2017-08-01

    Nowadays, credit scoring system plays an important role in banking sector. This process is important in assessing the creditworthiness of customers requesting credit from banks or other financial institutions. Usually, the credit scoring is used when customers send the application for credit facilities. Based on the score from credit scoring, bank will be able to segregate the "good" clients from "bad" clients. However, in most cases the score is useful at that specific time only and cannot be used to forecast the credit worthiness of the same applicant after that. Hence, bank will not know if "good" clients will always be good all the time or "bad" clients may become "good" clients after certain time. To fill up the gap, this study proposes an equation to forecast the credit scoring of the potential borrowers at a certain time by using the historical score related to the assumption. The Mean Absolute Percentage Error (MAPE) is used to measure the accuracy of the forecast scoring. Result shows the forecast scoring is highly accurate as compared to actual credit scoring.

  15. Management of Coronary Artery Disease in South Asian Populations: Why and How to Prevent and Treat Differently.

    PubMed

    Ahmed, Emad; El-Menyar, Ayman

    2016-03-01

    The South Asian (SA) population constitutes one of the largest ethnic groups in the world. Several studies that compared host and migrant populations around the world indicate that SAs have a higher risk of developing cardiovascular disease (CVD) than their native-born counterparts. Herein, we review the literature to address the role of the screening tools, scoring systems, and guidelines for primary, secondary, and tertiary prevention in these populations. Management based on screening for the CVD risk factors in a high-risk population such as SAs can improve health care outcomes. There are many scoring tools for calculating 10-year CVD risk; however, each scoring system has its limitations in this particular ethnicity. Further work is needed to establish a unique scoring and guidelines in SAs. © The Author(s) 2015.

  16. A proposed method for world weightlifting championships team selection.

    PubMed

    Chiu, Loren Z F

    2009-08-01

    The caliber of competitors at the World Weightlifting Championships (WWC) has increased greatly over the past 20 years. As the WWC are the primary qualifiers for Olympic slots (1996 to present), it is imperative for a nation to select team members who will finish with a high placing and score team points. Previous selection methods were based on a simple percentage system. Analysis of the results from the 2006 and 2007 WWC indicates a curvilinear trend in each weight class, suggesting a simple percentage system will not maximize the number of team points earned. To maximize team points, weightlifters should be selected based on their potential to finish in the top 25. A 5-tier ranking system is proposed that should ensure the athletes with the greatest potential to score team points are selected.

  17. A simple scoring system for predicting early major complications in spine surgery: the cumulative effect of age and size of surgery.

    PubMed

    Brasil, Albert Vincent Berthier; Teles, Alisson R; Roxo, Marcelo Ricardo; Schuster, Marcelo Neutzling; Zauk, Eduardo Ballverdu; Barcellos, Gabriel da Costa; Costa, Pablo Ramon Fruett da; Ferreira, Nelson Pires; Kraemer, Jorge Luiz; Ferreira, Marcelo Paglioli; Gobbato, Pedro Luis; Worm, Paulo Valdeci

    2016-10-01

    To analyze the cumulative effect of risk factors associated with early major complications in postoperative spine surgery. Retrospective analysis of 583 surgically-treated patients. Early "major" complications were defined as those that may lead to permanent detrimental effects or require further significant intervention. A balanced risk score was built using multiple logistic regression. Ninety-two early major complications occurred in 76 patients (13%). Age > 60 years and surgery of three or more levels proved to be significant independent risk factors in the multivariate analysis. The balanced scoring system was defined as: 0 points (no risk factor), 2 points (1 factor) or 4 points (2 factors). The incidence of early major complications in each category was 7% (0 points), 15% (2 points) and 29% (4 points) respectively. This balanced scoring system, based on two risk factors, represents an important tool for both surgical indication and for patient counseling before surgery.

  18. Variations in the perception of trauma-related complications between attending surgeons, surgery residents, critical care nurses, and medical students.

    PubMed

    Dissanaike, Sharmila; Berry, Matthew; Ginos, Jason; Paige, Robert; McNabb, Wendi; Griswold, John

    2009-06-01

    The morbidity and mortality conference (M&M) is a key component of the performance improvement process. The audience response system (ARS) has been shown to improve audience participation and promote more truthful responses in various settings. We implemented the ARS in our trauma M&M and evaluated the responses we received from different categories of participants. This was a prospective observational study undertaken between November 2006 and July 2007. Cases were graded based on the American College of Surgeons scoring system. We evaluated the responses of attending surgeons, residents, critical care nurses, and medical students using the ARS. We had 695 responses for complications and 936 responses for deaths. Residents consistently scored complications as more severe than other groups (P = .03). There was no difference in the scoring of deaths. Surgical residents assign higher severity to trauma-related complications than other groups when using an anonymous automated scoring system.

  19. SPIDERplan: A tool to support decision-making in radiation therapy treatment plan assessment.

    PubMed

    Ventura, Tiago; Lopes, Maria do Carmo; Ferreira, Brigida Costa; Khouri, Leila

    2016-01-01

    In this work, a graphical method for radiotherapy treatment plan assessment and comparison, named SPIDERplan, is proposed. It aims to support plan approval allowing independent and consistent comparisons of different treatment techniques, algorithms or treatment planning systems. Optimized plans from modern radiotherapy are not easy to evaluate and compare because of their inherent multicriterial nature. The clinical decision on the best treatment plan is mostly based on subjective options. SPIDERplan combines a graphical analysis with a scoring index. Customized radar plots based on the categorization of structures into groups and on the determination of individual structures scores are generated. To each group and structure, an angular amplitude is assigned expressing the clinical importance defined by the radiation oncologist. Completing the graphical evaluation, a global plan score, based on the structures score and their clinical weights, is determined. After a necessary clinical validation of the group weights, SPIDERplan efficacy, to compare and rank different plans, was tested through a planning exercise where plans had been generated for a nasal cavity case using different treatment planning systems. SPIDERplan method was applied to the dose metrics achieved by the nasal cavity test plans. The generated diagrams and scores successfully ranked the plans according to the prescribed dose objectives and constraints and the radiation oncologist priorities, after a necessary clinical validation process. SPIDERplan enables a fast and consistent evaluation of plan quality considering all targets and organs at risk.

  20. The tissue microarray data exchange specification: Extending TMA DES to provide flexible scoring and incorporate virtual slides

    PubMed Central

    Wright, Alexander; Lyttleton, Oliver; Lewis, Paul; Quirke, Philip; Treanor, Darren

    2011-01-01

    Background: Tissue MicroArrays (TMAs) are a high throughput technology for rapid analysis of protein expression across hundreds of patient samples. Often, data relating to TMAs is specific to the clinical trial or experiment it is being used for, and not interoperable. The Tissue Microarray Data Exchange Specification (TMA DES) is a set of eXtensible Markup Language (XML)-based protocols for storing and sharing digitized Tissue Microarray data. XML data are enclosed by named tags which serve as identifiers. These tag names can be Common Data Elements (CDEs), which have a predefined meaning or semantics. By using this specification in a laboratory setting with increasing demands for digital pathology integration, we found that the data structure lacked the ability to cope with digital slide imaging in respect to web-enabled digital pathology systems and advanced scoring techniques. Materials and Methods: By employing user centric design, and observing behavior in relation to TMA scoring and associated data, the TMA DES format was extended to accommodate the current limitations. This was done with specific focus on developing a generic tool for handling any given scoring system, and utilizing data for multiple observations and observers. Results: DTDs were created to validate the extensions of the TMA DES protocol, and a test set of data containing scores for 6,708 TMA core images was generated. The XML was then read into an image processing algorithm to utilize the digital pathology data extensions, and scoring results were easily stored alongside the existing multiple pathologist scores. Conclusions: By extending the TMA DES format to include digital pathology data and customizable scoring systems for TMAs, the new system facilitates the collaboration between pathologists and organizations, and can be used in automatic or manual data analysis. This allows complying systems to effectively communicate complex and varied scoring data. PMID:21572508

  1. Risk Factors for Venous Thromboembolism in Pediatric Trauma Patients and Validation of a Novel Scoring System: The Risk of Clots in Kids with Trauma (ROCKIT score)

    PubMed Central

    Yen, Jennifer; Van Arendonk, Kyle J.; Streiff, Michael B.; McNamara, LeAnn; Stewart, F. Dylan; Conner G, Kim G; Thompson, Richard E.; Haut, Elliott R.; Takemoto, Clifford M.

    2017-01-01

    OBJECTIVES Identify risk factors for venous thromboembolism (VTE) and develop a VTE risk assessment model for pediatric trauma patients. DESIGN, SETTING, AND PATIENTS We performed a retrospective review of patients 21 years and younger who were hospitalized following traumatic injuries at the John Hopkins level 1 adult and pediatric trauma center (1987-2011). The clinical characteristics of patients with and without VTE were compared, and multivariable logistic regression analysis was used to identify independent risk factors for VTE. Weighted risk assessment scoring systems were developed based on these and previously identified factors from patients in the National Trauma Data Bank (NTDB 2008-2010); the scoring systems were validated in this cohort from Johns Hopkins as well as a cohort of pediatric admissions from the NTDB (2011-2012). MAIN RESULTS Forty-nine of 17,366 pediatric trauma patients (0.28%) were diagnosed with VTE after admission to our trauma center. After adjusting for potential confounders, VTE was independently associated with older age, surgery, blood transfusion, higher Injury Severity Score (ISS), and lower Glasgow Coma Scale (GCS) score. These and additional factors were identified in 402,329 pediatric patients from the NTDB from 2008-2010; independent risk factors from the logistic regression analysis of this NTDB cohort were selected and incorporated into weighted risk assessment scoring systems. Two models were developed and were cross-validated in 2 separate pediatric trauma cohorts: 1) 282,535 patients in the NTDB from 2011 to 2012 2) 17,366 patients from Johns Hopkins. The receiver operator curve using these models in the validation cohorts had area under the curves that ranged 90% to 94%. CONCLUSIONS VTE is infrequent after trauma in pediatric patients. We developed weighted scoring systems to stratify pediatric trauma patients at risk for VTE. These systems may have potential to guide risk-appropriate VTE prophylaxis in children after trauma. PMID:26963757

  2. Differential diagnosis between benign and malignant soft tissue tumors utilizing ultrasound parameters.

    PubMed

    Morii, Takeshi; Kishino, Tomonori; Shimamori, Naoko; Motohashi, Mitsue; Ohnishi, Hiroaki; Honya, Keita; Aoyagi, Takayuki; Tajima, Takashi; Ichimura, Shoichi

    2018-01-01

    Preoperative discrimination between benign and malignant soft tissue tumors is critical for the prevention of excess application of magnetic resonance imaging and biopsy as well as unplanned resection. Although ultrasound, including power Doppler imaging, is an easy, noninvasive, and cost-effective modality for screening soft tissue tumors, few studies have investigated reliable discrimination between benign and malignant soft tissue tumors. To establish a modality for discrimination between benign and malignant soft tissue tumors using ultrasound, we extracted the significant risk factors for malignancy based on ultrasound information from 40 malignant and 56 benign pathologically diagnosed soft tissue tumors and established a scoring system based on these risk factors. The maximum size, tumor margin, and vascularity evaluated using ultrasound were extracted as significant risk factors. Using the odds ratio from a multivariate regression model, a scoring system was established. Receiver operating characteristic analyses revealed a high area under the curve value (0.85), confirming the accuracy of the scoring system. Ultrasound is a useful modality for establishing the differential diagnosis between benign and malignant soft tissue tumors.

  3. Screening Internet websites for educational potential in undergraduate medical education.

    PubMed

    Burd, Andrew; Chiu, Tor; McNaught, Carmel

    2004-01-01

    This paper addresses the difficulty of finding suitable websites to support undergraduate medical students in learning key concepts and skills in plastic surgery in particular, and other areas of undergraduate medical education in general. Based on a model of the pedagogical elements contained in educational websites, the authors developed a short objective scoring system with five criteria. Pre-university students were used to find websites in plastic surgery. One hundred and fifty of those that were still in place after a year were evaluated using the objective scoring system. Sixty of these were then selected and were subjectively evaluated by final year medical students in terms of their perceived educational potential. There was only a moderate correlation between the objective and subjective scores. Our conclusion is that it does not seem possible to construct any objective system of medical website evaluation. The discussion of the results of this study focuses on the issues involved in finding suitable web-based material and the diversity between students. New strategies such as formally organized consortia involving agreements between medical schools may evolve.

  4. Which AIS based scoring system is the best predictor of outcome in orthopaedic blunt trauma patients?

    PubMed

    Harwood, Paul J; Giannoudis, Peter V; Probst, Christian; Van Griensven, Martijn; Krettek, Christian; Pape, Hans-Christoph

    2006-02-01

    Abbreviated Injury Scale (AIS)-based systems-the Injury Severity Score (ISS), New Injury Severity Score (NISS), and AISmax-are used to assess trauma patients. The merits of each in predicting outcome are controversial. A large prospective database was used to assess their predictive capacity using receiver operator characteristic curves. In all, 10,062 adult, blunt-trauma patients met the inclusion criteria. All systems were significant outcome predictors for sepsis, multiple organ failure (MOF), length of hospital stay, length of intensive care unit (ICU) admission and mortality (p < 0.0001). NISS was a significantly better predictor than the ISS for mortality (p < 0.0001). NISS was equivalent to the AISmax for mortality prediction and superior in patients with orthopaedic injuries. NISS was significantly better for sepsis, MOF, ICU stay, and total hospital stay (p < 0.0001). NISS is superior or equivalent to the ISS and AISmax for prediction of all investigated outcomes in a population of blunt trauma patients. As NISS is easier to calculate, its use is recommended to stratify patients for clinical and research purposes.

  5. The Comparison of Iranian Normative Reference Data with Five Countries ‎Across Variables in Eight Rorschach Comprehensive System (CS) Clusters

    PubMed Central

    Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali

    2016-01-01

    Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-‎patient Iranian children respond to the Rorschach test. We compared this especial sample to ‎international normative reference values for the Comprehensive System (CS).‎ Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public ‎schools. Using five child and adolescent samples from five countries, we compared Iranian ‎Normative Reference Data- based on reference means and standard deviations for each sample.‎ Results: Findings revealed that how the scores in each sample were distributed and how the samples were ‎compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported ‎all descriptive statistics such as reference mean and standard deviation for all variables.‎ Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We ‎discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences ‎about psychopathology in children and adolescents.‎ PMID:27928247

  6. An Inmate Classification System Based on PCL: SV Factor Scores in a Sample of Prison Inmates

    ERIC Educational Resources Information Center

    Wogan, Michael; Mackenzie, Marci

    2007-01-01

    Psychopaths represent a significant management challenge in a prison population. A sample of ninety-five male inmates from three medium security prisons was tested using the Hare Psychopathy Checklist: Screening Version (PCL:SV). Using traditional criteria, 22% of the inmates were classified as psychopaths. Scores on the two factor dimensions of…

  7. A Quality-Based Payment Strategy for Nursing Home Care in Minnesota

    ERIC Educational Resources Information Center

    Kane, Robert L.; Arling, Greg; Mueller, Christine; Held, Robert; Cooke, Valerie

    2007-01-01

    This article describes a pay-for-performance system developed for Minnesota nursing homes. In effect, nursing homes can retain a greater proportion of the difference between their costs and the average costs on the basis of their quality scores. The quality score is a derived and weighted composite measure currently composed of five elements:…

  8. Microcomputer Applications for Library Instruction: Automation of Test and Assignment Scoring, and Student Record Keeping.

    ERIC Educational Resources Information Center

    Sugranes, Maria R.; Snider, Larry C.

    1985-01-01

    Describes the development of an automated library instruction records management system using microcomputer technology. Development described includes assessment of need, exploration of options, system design, and operational development. System products are identified and operational results are reported based on actual system performance.…

  9. Comparison of scoring systems for nonvariceal upper gastrointestinal bleeding: a multicenter prospective cohort study.

    PubMed

    Yang, Hae Min; Jeon, Seong Woo; Jung, Jin Tae; Lee, Dong Wook; Ha, Chang Yoon; Park, Kyung Sik; Lee, Si Hyung; Yang, Chang Heon; Park, Jun Hyung; Park, Youn Sun

    2016-01-01

    The Glasgow-Blatchford score (GBS) and Rockall score (RS) are widely used to assess risk in patients with upper gastrointestinal bleeding (UGIB). We compared both scoring systems and evaluated their clinical usefulness. Between February 2011 and December 2013, 1584 patients with nonvariceal UGIB were included in the study. A prospective study was conducted to compare the performance of the GBS, pre-RS, and full RS. We compared the performance of these scores using receiver operating characteristic curves. For prediction of the need for hospital-based intervention, the GBS was similar to the full RS (area under the receiver operating characteristic curves [AUROC] 0.705 vs 0.727; P = 0.282) and superior to the pre-RS (AUROC 0.705 vs 0.601; P < 0.0001). In predicting death, the full RS was superior to the GBS (AUROC 0.758 vs 0.644; P = 0.0006) and similar to the pre-RS (AUROC 0.758 vs 0.754; P = 0.869). In predicting rebleeding, the full RS was superior to both GBS (AUROC 0.642 vs 0.585; P = 0.031) and pre-RS (AUROC 0.642 vs 0.593; P = 0.0003). Of 1584 patients, 13 (0.8%) scored 0 on the GBS. Therapeutic intervention was not performed in any of these patients. The GBS is more useful than the pre-RS for predicting the need for hospital-based intervention. A cutoff value of 0 for low-risk patients who might be suitable for outpatient management is useful. The full RS is helpful in predicting death. None of the systems accurately predict rebleeding with a low AUROC. ( cris.nih.go.kr/KCT0000514). © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  10. Logistical Consideration in Computer-Based Screening of Astronaut Applicants

    NASA Technical Reports Server (NTRS)

    Galarza, Laura

    2000-01-01

    This presentation reviews the logistical, ergonomic, and psychometric issues and data related to the development and operational use of a computer-based system for the psychological screening of astronaut applicants. The Behavioral Health and Performance Group (BHPG) at the Johnson Space Center upgraded its astronaut psychological screening and selection procedures for the 1999 astronaut applicants and subsequent astronaut selection cycles. The questionnaires, tests, and inventories were upgraded from a paper-and-pencil system to a computer-based system. Members of the BHPG and a computer programmer designed and developed needed interfaces (screens, buttons, etc.) and programs for the astronaut psychological assessment system. This intranet-based system included the user-friendly computer-based administration of tests, test scoring, generation of reports, the integration of test administration and test output to a single system, and a complete database for past, present, and future selection data. Upon completion of the system development phase, four beta and usability tests were conducted with the newly developed system. The first three tests included 1 to 3 participants each. The final system test was conducted with 23 participants tested simultaneously. Usability and ergonomic data were collected from the system (beta) test participants and from 1999 astronaut applicants who volunteered the information in exchange for anonymity. Beta and usability test data were analyzed to examine operational, ergonomic, programming, test administration and scoring issues related to computer-based testing. Results showed a preference for computer-based testing over paper-and -pencil procedures. The data also reflected specific ergonomic, usability, psychometric, and logistical concerns that should be taken into account in future selection cycles. Conclusion. Psychological, psychometric, human and logistical factors must be examined and considered carefully when developing and using a computer-based system for psychological screening and selection.

  11. French adaptation of the new Knee Society Scoring System for total knee arthroplasty.

    PubMed

    Debette, C; Parratte, S; Maucort-Boulch, D; Blanc, G; Pauly, V; Lustig, S; Servien, E; Neyret, P; Argenson, J N

    2014-09-01

    In November 2011, the Knee Society published its new KSS score to evaluate objective clinical data and also patient expectations, satisfaction and knee function during various physical activities before and after total knee arthroplasty (TKA). We undertook the French cross-cultural adaptation of this scoring system according to current recommendations. The French version of the new KSS score is a consistent, feasible, reliable and discriminating score. Eighty patients with knee osteoarthritis were recruited from two centers: one group of 40 patients had a TKA indication, while the other group of 40 patients had an indication for conservative treatment. After the new KSS score was translated and back-translated, it was compared to three other validated instruments (KOOS, AMIQUAL and SF-12) to determine construct validity, discriminating power, feasibility in terms of response rate and existence of floor or ceiling effect, internal consistency with Chronbach's alpha and reliability based on reproducibility and sensitivity to change (responsiveness). Due to missing data, two cases were eliminated. We found that the score could discriminate between groups; it had a nearly 100% response rate, a ceiling effect in the "expectations" domain, satisfactory Chronbach's alpha, excellent reproducibility and good responsiveness. These results confirm that the French version of the new KSS score is reliable, feasible, discriminating, consistent and responsive. The novelty of this scoring system resides in the "expectations" and "satisfaction" domains, its availability as a self-assessment questionnaire and the evaluation of function during various activities. Level III. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. A robust fingerprint matching algorithm based on compatibility of star structures

    NASA Astrophysics Data System (ADS)

    Cao, Jia; Feng, Jufu

    2009-10-01

    In fingerprint verification or identification systems, most minutiae-based matching algorithms suffered from the problems of non-linear distortion and missing or faking minutiae. Local structures such as triangle or k-nearest structure are widely used to reduce the impact of non-linear distortion, but are suffered from missing and faking minutiae. In our proposed method, star structure is used to present local structure. A star structure contains various number of minutiae, thus, it is more robust with missing and faking minutiae. Our method consists of four steps: 1) Constructing star structures at minutia level; 2) Computing similarity score for each structure pair, and eliminating impostor matched pairs which have the low scores. As it is generally assumed that there is only linear distortion in local area, the similarity is defined by rotation and shifting. 3) Voting for remained matched pairs according to the compatibility between them, and eliminating impostor matched pairs which gain few votes. The concept of compatibility is first introduced by Yansong Feng [4], the original definition is only based on triangles. We define the compatibility for star structures to adjust to our proposed algorithm. 4) Computing the matching score, based on the number of matched structures and their voting scores. The score also reflects the fact that, it should get higher score if minutiae match in more intensive areas. Experiments evaluated on FVC 2004 show both effectiveness and efficiency of our methods.

  13. Histological and reference system for the analysis of mouse intervertebral disc.

    PubMed

    Tam, Vivian; Chan, Wilson C W; Leung, Victor Y L; Cheah, Kathryn S E; Cheung, Kenneth M C; Sakai, Daisuke; McCann, Matthew R; Bedore, Jake; Séguin, Cheryle A; Chan, Danny

    2018-01-01

    A new scoring system based on histo-morphology of mouse intervertebral disc (IVD) was established to assess changes in different mouse models of IVD degeneration and repair. IVDs from mouse strains of different ages, transgenic mice, or models of artificially induced IVD degeneration were assessed. Morphological features consistently observed in normal, and early/later stages of degeneration were categorized into a scoring system focused on nucleus pulposus (NP) and annulus fibrosus (AF) changes. "Normal NP" exhibited a highly cellularized cell mass that decreased with natural ageing and in disc degeneration. "Normal AF" consisted of distinct concentric lamellar structures, which was disrupted in severe degeneration. NP/AF clefts indicated more severe changes. Consistent scores were obtained between experienced and new users. Altogether, our scoring system effectively differentiated IVD changes in various strains of wild-type and genetically modified mice and in induced models of IVD degeneration, and is applicable from the post-natal stage to the aged mouse. This scoring tool and reference resource addresses a pressing need in the field for studying IVD changes and cross-study comparisons in mice, and facilitates a means to normalize mouse IVD assessment between different laboratories. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:233-243, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Testing the Efficacy of Global Biodiversity Hotspots for Insect Conservation: The Case of South African Katydids.

    PubMed

    Bazelet, Corinna S; Thompson, Aileen C; Naskrecki, Piotr

    2016-01-01

    The use of endemism and vascular plants only for biodiversity hotspot delineation has long been contested. Few studies have focused on the efficacy of global biodiversity hotspots for the conservation of insects, an important, abundant, and often ignored component of biodiversity. We aimed to test five alternative diversity measures for hotspot delineation and examine the efficacy of biodiversity hotspots for conserving a non-typical target organism, South African katydids. Using a 1° fishnet grid, we delineated katydid hotspots in two ways: (1) count-based: grid cells in the top 10% of total, endemic, threatened and/or sensitive species richness; vs. (2) score-based: grid cells with a mean value in the top 10% on a scoring system which scored each species on the basis of its IUCN Red List threat status, distribution, mobility and trophic level. We then compared katydid hotspots with each other and with recognized biodiversity hotspots. Grid cells within biodiversity hotspots had significantly higher count-based and score-based diversity than non-hotspot grid cells. There was a significant association between the three types of hotspots. Of the count-based measures, endemic species richness was the best surrogate for the others. However, the score-based measure out-performed all count-based diversity measures. Species richness was the least successful surrogate of all. The strong performance of the score-based method for hotspot prediction emphasizes the importance of including species' natural history information for conservation decision-making, and is easily adaptable to other organisms. Furthermore, these results add empirical support for the efficacy of biodiversity hotspots in conserving non-target organisms.

  15. Testing the Efficacy of Global Biodiversity Hotspots for Insect Conservation: The Case of South African Katydids

    PubMed Central

    Bazelet, Corinna S.; Thompson, Aileen C.; Naskrecki, Piotr

    2016-01-01

    The use of endemism and vascular plants only for biodiversity hotspot delineation has long been contested. Few studies have focused on the efficacy of global biodiversity hotspots for the conservation of insects, an important, abundant, and often ignored component of biodiversity. We aimed to test five alternative diversity measures for hotspot delineation and examine the efficacy of biodiversity hotspots for conserving a non-typical target organism, South African katydids. Using a 1° fishnet grid, we delineated katydid hotspots in two ways: (1) count-based: grid cells in the top 10% of total, endemic, threatened and/or sensitive species richness; vs. (2) score-based: grid cells with a mean value in the top 10% on a scoring system which scored each species on the basis of its IUCN Red List threat status, distribution, mobility and trophic level. We then compared katydid hotspots with each other and with recognized biodiversity hotspots. Grid cells within biodiversity hotspots had significantly higher count-based and score-based diversity than non-hotspot grid cells. There was a significant association between the three types of hotspots. Of the count-based measures, endemic species richness was the best surrogate for the others. However, the score-based measure out-performed all count-based diversity measures. Species richness was the least successful surrogate of all. The strong performance of the score-based method for hotspot prediction emphasizes the importance of including species’ natural history information for conservation decision-making, and is easily adaptable to other organisms. Furthermore, these results add empirical support for the efficacy of biodiversity hotspots in conserving non-target organisms. PMID:27631131

  16. The ADOPT-LC score: a novel predictive index of in-hospital mortality of cirrhotic patients following surgical procedures, based on a national survey.

    PubMed

    Sato, Masaya; Tateishi, Ryosuke; Yasunaga, Hideo; Horiguchi, Hiromasa; Matsui, Hiroki; Yoshida, Haruhiko; Fushimi, Kiyohide; Koike, Kazuhiko

    2017-03-01

    We aimed to develop a model for predicting in-hospital mortality of cirrhotic patients following major surgical procedures using a large sample of patients derived from a Japanese nationwide administrative database. We enrolled 2197 cirrhotic patients who underwent elective (n = 1973) or emergency (n = 224) surgery. We analyzed the risk factors for postoperative mortality and established a scoring system for predicting postoperative mortality in cirrhotic patients using a split-sample method. In-hospital mortality rates following elective or emergency surgery were 4.7% and 20.5%, respectively. In multivariate analysis, patient age, Child-Pugh (CP) class, Charlson Comorbidity Index (CCI), and duration of anesthesia in elective surgery were significantly associated with in-hospital mortality. In emergency surgery, CP class and duration of anesthesia were significant factors. Based on multivariate analysis in the training set (n = 987), the Adequate Operative Treatment for Liver Cirrhosis (ADOPT-LC) score that used patient age, CP class, CCI, and duration of anesthesia to predict in-hospital mortality following elective surgery was developed. This scoring system was validated in the testing set (n = 986) and produced an area under the curve of 0.881. We also developed iOS/Android apps to calculate ADOPT-LC scores to allow easy access to the current evidence in daily clinical practice. Patient age, CP class, CCI, and duration of anesthesia were identified as important risk factors for predicting postoperative mortality in cirrhotic patients. The ADOPT-LC score effectively predicts in-hospital mortality following elective surgery and may assist decisions regarding surgical procedures in cirrhotic patients based on a quantitative risk assessment. © 2016 The Authors Hepatology Research published by John Wiley & Sons Australia, Ltd on behalf of Japan Society of Hepatology.

  17. Automated Measurement of Visual Acuity in Pediatric Ophthalmic Patients Using Principles of Game Design and Tablet Computers.

    PubMed

    Aslam, Tariq M; Tahir, Humza J; Parry, Neil R A; Murray, Ian J; Kwak, Kun; Heyes, Richard; Salleh, Mahani M; Czanner, Gabriela; Ashworth, Jane

    2016-10-01

    To report on the utility of a computer tablet-based method for automated testing of visual acuity in children based on the principles of game design. We describe the testing procedure and present repeatability as well as agreement of the score with accepted visual acuity measures. Reliability and validity study. Setting: Manchester Royal Eye Hospital Pediatric Ophthalmology Outpatients Department. Total of 112 sequentially recruited patients. For each patient 1 eye was tested with the Mobile Assessment of Vision by intERactIve Computer for Children (MAVERIC-C) system, consisting of a software application running on a computer tablet, housed in a bespoke viewing chamber. The application elicited touch screen responses using a game design to encourage compliance and automatically acquire visual acuity scores of participating patients. Acuity was then assessed by an examiner with a standard chart-based near ETDRS acuity test before the MAVERIC-C assessment was repeated. Reliability of MAVERIC-C near visual acuity score and agreement of MAVERIC-C score with near ETDRS chart for visual acuity. Altogether, 106 children (95%) completed the MAVERIC-C system without assistance. The vision scores demonstrated satisfactory reliability, with test-retest VA scores having a mean difference of 0.001 (SD ±0.136) and limits of agreement of 2 SD (LOA) of ±0.267. Comparison with the near EDTRS chart showed agreement with a mean difference of -0.0879 (±0.106) with LOA of ±0.208. This study demonstrates promising utility for software using a game design to enable automated testing of acuity in children with ophthalmic disease in an objective and accurate manner. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Who to handover: a case-control study of a novel scoring system to prioritise handover of internal medicine inpatients.

    PubMed

    Bittman, Jesse; Tam, Penny; Little, Chris; Khan, Nadia

    2017-06-01

    Handover of patients between care providers is a critical event in patient care. There is, however, little evidence to guide the handover process, including determining which patients to handover. Compare the ability of gestalt-based handover with two structured scores, the modified early warning score (MEWS) and our novel iHAND clinical decision support system, to predict which patients will be assessed by a physician overnight. This case-control study included 90 inpatients, comprising 32 patients assessed overnight (cases) and 58 patients not assessed overnight (controls) at a teaching hospital in British Columbia, Canada (May 2012). Gestalt, MEWS and iHAND scores were analysed against patients seen overnight using logistic regression and receiver-operating characteristic (ROC) curves. Neither current gestalt-based handover practice (odds ratio (OR) 1.50, 95% CI 0.89 to 3.83) nor MEWS (OR 0.96, 95% CI 0.75 to 1.24, area under the ROC curve (AUC) 0.61, 95% CI 0.49 to 0.73) were significantly associated with need to be seen overnight. The iHAND score was associated with need to be seen (OR 1.93, 95% CI 1.24 to 3.02, AUC 0.70, 95% CI 0.60 to 0.81). The iHAND score had moderate ability to predict which patients required assessment overnight, while MEWS score and current gestalt approach correlated poorly, suggesting the iHAND score may help prioritisation of patients likely to be seen overnight for handover. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Psoriasis image representation using patch-based dictionary learning for erythema severity scoring.

    PubMed

    George, Yasmeen; Aldeen, Mohammad; Garnavi, Rahil

    2018-06-01

    Psoriasis is a chronic skin disease which can be life-threatening. Accurate severity scoring helps dermatologists to decide on the treatment. In this paper, we present a semi-supervised computer-aided system for automatic erythema severity scoring in psoriasis images. Firstly, the unsupervised stage includes a novel image representation method. We construct a dictionary, which is then used in the sparse representation for local feature extraction. To acquire the final image representation vector, an aggregation method is exploited over the local features. Secondly, the supervised phase is where various multi-class machine learning (ML) classifiers are trained for erythema severity scoring. Finally, we compare the proposed system with two popular unsupervised feature extractor methods, namely: bag of visual words model (BoVWs) and AlexNet pretrained model. Root mean square error (RMSE) and F1 score are used as performance measures for the learned dictionaries and the trained ML models, respectively. A psoriasis image set consisting of 676 images, is used in this study. Experimental results demonstrate that the use of the proposed procedure can provide a setup where erythema scoring is accurate and consistent. Also, it is revealed that dictionaries with large number of atoms and small patch sizes yield the best representative erythema severity features. Further, random forest (RF) outperforms other classifiers with F1 score 0.71, followed by support vector machine (SVM) and boosting with 0.66 and 0.64 scores, respectively. Furthermore, the conducted comparative studies confirm the effectiveness of the proposed approach with improvement of 9% and 12% over BoVWs and AlexNet based features, respectively. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  20. The JAGUAR Score Predicts 1-Month Disability/Death in Ischemic Stroke Patient Ineligible for Recanalization Therapy.

    PubMed

    Widhi Nugroho, Aryandhito; Arima, Hisatomi; Takashima, Naoyuki; Fujii, Takako; Shitara, Satoshi; Miyamatsu, Naomi; Sugimoto, Yoshihisa; Nagata, Satoru; Komori, Masaru; Kita, Yoshikuni; Miura, Katsuyuki; Nozaki, Kazuhiko

    2018-06-22

    Most available scoring system to predict outcome after acute ischemic stroke (AIS) were established in Western countries. We aimed to develop a simple prediction score of 1-month severe disability/death after onset in AIS patients ineligible for recanalization therapy based on readily and widely obtainable on-admission clinical, laboratory and radiological examinations in Asian developing countries. Using the Shiga Stroke Registry, a large population-based registry in Japan, multivariable logistic regression analysis was conducted in 1617 AIS patients ineligible for recanalization therapy to yield ß-coefficients of significant predictors of 1-month modified Rankin Scale score of 5-6, which were then multiplied by a specific constant and rounded to nearest integer to develop 0-10 points system. Model discrimination and calibration were evaluated in the original and bootstrapped population. Japan Coma Scale score (J), age (A), random glucose (G), untimely onset-to-arrival time (U), atrial fibrillation (A), and preadmission dependency status according to the modified Rankin Scale score (R), were recognized as independent predictors of outcome. Each of their β-coefficients was multiplied by 1.3 creating the JAGUAR score. Its area under the curve (95% confidence interval) was .901 (.880- .922) and .901 (.900- .901) in the original and bootstrapped population, respectively. It was found to have good calibration in both study population (P = .27). The JAGUAR score can be an important prediction tool of severe disability/death in AIS patients ineligible for recanalization therapy that can be applied on admission with no complicated calculation and multimodal neuroimaging necessary, thus suitable for Asian developing countries. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Validation of a Predictive Scoring System for Deep Sternal Wound Infection after Bilateral Internal Thoracic Artery Grafting in a Cohort of French Patients.

    PubMed

    Perrotti, Andrea; Gatti, Giuseppe; Dorigo, Enrica; Sinagra, Gianfranco; Pappalardo, Aniello; Chocron, Sidney

    The Gatti score is a weighted scoring system based on risk factors for deep sternal wound infection (DSWI) that was created in an Italian center to predict DSWI risk after bilateral internal thoracic artery (BITA) grafting. No external evaluation based on validation samples derived from other surgical centers has been performed. The aim of this study is to perform this validation. During 2015, BITA grafts were used as skeletonized conduits in all 255 consecutive patients with multi-vessel coronary disease who underwent isolated coronary bypass surgery at the Department of Thoracic and Cardio-Vascular Surgery, University Hospital Jean Minjoz, Besançon, France. Baseline characteristics, operative data, and immediate outcomes of every patient were collected prospectively. A DSWI risk score was assigned to each patient pre-operatively. The discrimination power of both models, pre-operative and combined, of the Gatti score was assessed with the calculation of the area under the receiver operating characteristic curve. Fourteen (5.5%) patients had DSWI. Major differences both as the baseline characteristics of patients and surgical techniques were found between this series and the original series from which the Gatti score was derived. The area under the receiver operating characteristic curve was 0.78 (95% confidence interval: 0.64-0.92) for the pre-operative model and 0.84 (95% confidence interval: 0.69-0.98) for the combined model. The Gatti score has proven to be effective even in a cohort of French patients despite major differences from the original Italian series. Multi-center validation studies must be performed before introducing the score into clinical practice.

  2. Novel pathologic scoring tools predict end-stage kidney disease in light chain (AL) amyloidosis.

    PubMed

    Rubinstein, Samuel; Cornell, Robert F; Du, Liping; Concepcion, Beatrice; Goodman, Stacey; Harrell, Shelton; Horst, Sara; Lenihan, Daniel; Slosky, David; Fogo, Agnes; Langone, Anthony

    2017-09-01

    Light chain (AL) amyloidosis frequently involves the kidney, causing significant morbidity and mortality. A pathologic scoring system with prognostic utility has not been developed. We hypothesized that the extent of amyloid deposition and degree of scarring injury on kidney biopsy, could provide prognostic value, and aimed to develop pathologic scoring tools based on these features. This is a case-control study of 39 patients treated for AL amyloidosis with biopsy-proven kidney involvement at a large academic medical center. Our novel scoring tools, composite scarring injury score (CSIS) and amyloid score (AS) were applied to each kidney biopsy. The primary outcome was progression to dialysis-dependent end-stage kidney disease (ESKD) using a 12-month landmark analysis. At 12 months, nine patients had progressed to ESKD. Patients with an AS ≥7.5 had a significantly higher cumulative incidence of ESKD than those with AS <7.5 (p = .04, 95% CI 0.13-0.64). Using a 12-month landmark analysis, AS correlated with progression to ESKD. These data suggest that a kidney biopsy, in addition to providing diagnostic information, can be the basis for a pathologic scoring system with prognostic significance.

  3. A multistage gene normalization system integrating multiple effective methods.

    PubMed

    Li, Lishuang; Liu, Shanshan; Li, Lihua; Fan, Wenting; Huang, Degen; Zhou, Huiwei

    2013-01-01

    Gene/protein recognition and normalization is an important preliminary step for many biological text mining tasks. In this paper, we present a multistage gene normalization system which consists of four major subtasks: pre-processing, dictionary matching, ambiguity resolution and filtering. For the first subtask, we apply the gene mention tagger developed in our earlier work, which achieves an F-score of 88.42% on the BioCreative II GM testing set. In the stage of dictionary matching, the exact matching and approximate matching between gene names and the EntrezGene lexicon have been combined. For the ambiguity resolution subtask, we propose a semantic similarity disambiguation method based on Munkres' Assignment Algorithm. At the last step, a filter based on Wikipedia has been built to remove the false positives. Experimental results show that the presented system can achieve an F-score of 90.1%, outperforming most of the state-of-the-art systems.

  4. How do Medical Societies Select Science for Conference Presentation? How Should They?

    PubMed Central

    Kuczmarski, Thomas M.; Raja, Ali S.; Pallin, Daniel J.

    2015-01-01

    Introduction Nothing has been published to describe the practices of medical societies in choosing abstracts for presentations at their annual meetings. We surveyed medical societies to determine their practices, and also present a theoretical analysis of the topic. Methods We contacted a convenience sample of large U.S. medical conferences, and determined their approach to choosing abstracts. We obtained information from web sites, telephone, and email. Our theoretical analysis compares values-based and empirical approaches for scoring system development. Results We contacted 32 societies and obtained data on 28 (response rate 88%). We excluded one upon learning that research was not presented at its annual meeting, leaving 27 for analysis. Only 2 (7%) made their abstract scoring process available to submitters. Reviews were blinded in most societies (21;78%), and all but one asked reviewers to recuse themselves for conflict of interest (96%). All required ≥3 reviewers. Of the 24 providing information on how scores were generated, 21 (88%) reported using a single gestalt score, and three used a combined score created from pooled domain-specific sub-scores. We present a framework for societies to use in choosing abstracts, and demonstrate its application in the development of a new scoring system. Conclusions Most medical societies use subjective, gestalt methods to select research for presentation at their annual meetings and do not disclose to submitters the details of how abstracts are chosen. We present a new scoring system that is transparent to submitters and reviewers alike with an accompanying statement of values and ground rules. We discuss the challenges faced in selecting abstracts for a large scientific meeting and share the values and practical considerations that undergird the new system. PMID:26265966

  5. How do Medical Societies Select Science for Conference Presentation? How Should They?

    PubMed

    Kuczmarski, Thomas M; Raja, Ali S; Pallin, Daniel J

    2015-07-01

    Nothing has been published to describe the practices of medical societies in choosing abstracts for presentations at their annual meetings. We surveyed medical societies to determine their practices, and also present a theoretical analysis of the topic. We contacted a convenience sample of large U.S. medical conferences, and determined their approach to choosing abstracts. We obtained information from web sites, telephone, and email. Our theoretical analysis compares values-based and empirical approaches for scoring system development. We contacted 32 societies and obtained data on 28 (response rate 88%). We excluded one upon learning that research was not presented at its annual meeting, leaving 27 for analysis. Only 2 (7%) made their abstract scoring process available to submitters. Reviews were blinded in most societies (21;78%), and all but one asked reviewers to recuse themselves for conflict of interest (96%). All required ≥3 reviewers. Of the 24 providing information on how scores were generated, 21 (88%) reported using a single gestalt score, and three used a combined score created from pooled domain-specific sub-scores. We present a framework for societies to use in choosing abstracts, and demonstrate its application in the development of a new scoring system. Most medical societies use subjective, gestalt methods to select research for presentation at their annual meetings and do not disclose to submitters the details of how abstracts are chosen. We present a new scoring system that is transparent to submitters and reviewers alike with an accompanying statement of values and ground rules. We discuss the challenges faced in selecting abstracts for a large scientific meeting and share the values and practical considerations that undergird the new system.

  6. Centile-based early warning scores derived from statistical distributions of vital signs.

    PubMed

    Tarassenko, Lionel; Clifton, David A; Pinsky, Michael R; Hravnak, Marilyn T; Woods, John R; Watkinson, Peter J

    2011-08-01

    To develop an early warning score (EWS) system based on the statistical properties of the vital signs in at-risk hospitalised patients. A large dataset comprising 64,622 h of vital-sign data, acquired from 863 acutely ill in-hospital patients using bedside monitors, was used to investigate the statistical properties of the four main vital signs. Normalised histograms and cumulative distribution functions were plotted for each of the four variables. A centile-based alerting system was modelled using the aggregated database. The means and standard deviations of our population's vital signs are very similar to those published in previous studies. When compared with EWS systems based on a future outcome, the cut-off values in our system are most different for respiratory rate and systolic blood pressure. With four-hourly observations in a 12-h shift, about 1 in 8 at-risk patients would trigger our alerting system during the shift. A centile-based EWS system will identify patients with abnormal vital signs regardless of their eventual outcome and might therefore be more likely to generate an alert when presented with patients with redeemable morbidity or avoidable mortality. We are about to start a stepped-wedge clinical trial gradually introducing an electronic version of our EWS system on the trauma wards in a teaching hospital. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. A simple prediction score for developing a hospital-acquired infection after acute ischemic stroke.

    PubMed

    Friedant, Adam J; Gouse, Brittany M; Boehme, Amelia K; Siegler, James E; Albright, Karen C; Monlezun, Dominique J; George, Alexander J; Beasley, Timothy Mark; Martin-Schild, Sheryl

    2015-03-01

    Hospital-acquired infections (HAIs) are a major cause of morbidity and mortality in acute ischemic stroke patients. Although prior scoring systems have been developed to predict pneumonia in ischemic stroke patients, these scores were not designed to predict other infections. We sought to develop a simple scoring system for any HAI. Patients admitted to our stroke center (July 2008-June 2012) were retrospectively assessed. Patients were excluded if they had an in-hospital stroke, unknown time from symptom onset, or delay from symptom onset to hospital arrival greater than 48 hours. Infections were diagnosed via clinical, laboratory, and imaging modalities using standard definitions. A scoring system was created to predict infections based on baseline patient characteristics. Of 568 patients, 84 (14.8%) developed an infection during their stays. Patients who developed infection were older (73 versus 64, P < .0001), more frequently diabetic (43.9% versus 29.1%, P = .0077), and had more severe strokes on admission (National Institutes of Health Stroke Scale [NIHSS] score 12 versus 5, P < .0001). Ranging from 0 to 7, the overall infection score consists of age 70 years or more (1 point), history of diabetes (1 point), and NIHSS score (0-4 conferred 0 points, 5-15 conferred 3 points, >15 conferred 5 points). Patients with an infection score of 4 or more were at 5 times greater odds of developing an infection (odds ratio, 5.67; 95% confidence interval, 3.28-9.81; P < .0001). In our sample, clinical, laboratory, and imaging information available at admission identified patients at risk for infections during their acute hospitalizations. If validated in other populations, this score could assist providers in predicting infections after ischemic stroke. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. The Cord Blood Apgar: a novel scoring system to optimize selection of banked cord blood grafts for transplantation

    PubMed Central

    Page, Kristin M.; Zhang, Lijun; Mendizabal, Adam; Wease, Stephen; Carter, Shelly; Shoulars, Kevin; Gentry, Tracy; Balber, Andrew E.; Kurtzberg, Joanne

    2012-01-01

    BACKGROUND Engraftment failure and delays, likely due to diminished cord blood unit (CBU) potency, remain major barriers to the overall success of unrelated umbilical cord blood transplantation (UCBT). To address this problem, we developed and retrospectively validated a novel scoring system, the Cord Blood Apgar (CBA), which is predictive of engraftment after UCBT. STUDY DESIGN AND METHODS In a single-center retrospective study, utilizing a database of 435 consecutive single cord myeloablative UCBTs performed between January 1, 2000, to December 31, 2008, precryopreservation and postthaw graft variables (total nucleated cell, CD34+, colony-forming units, mononuclear cell content, and volume) were initially correlated with neutrophil engraftment. Subsequently, based on the magnitude of hazard ratios (HRs) in univariate analysis, a weighted scoring system to predict CBU potency was developed using a randomly selected training data set and internally validated on the remaining data set. RESULTS The CBA assigns transplanted CBUs three scores: a precryopreservation score (PCS), a postthaw score (PTS), and a composite score (CS), which incorporates the PCS and PTS values. CBA-PCS scores, which could be used for initial unit selection, were predictive of neutrophil (CBA-PCS ≥ 7.75 vs. <7.75, HR 3.5; p < 0.0001) engraftment. Likewise, CBA-PTS and CS scores were strongly predictive of Day 42 neutrophil engraftment (CBA-PTS ≥ 9.5 vs. <9.5, HR 3.16, p < 0.0001; CBA-CS ≥ 17.75 vs. <17.75, HR 4.01, p < 0.0001). CONCLUSION The CBA is strongly predictive of engraftment after UCBT and shows promise for optimizing screening of CBU donors for transplantation. In the future, a segment could be assayed for the PTS score providing data to apply the CS for final CBU selection. PMID:21810098

  9. Effectiveness of a computer-aided neuroanatomy program for entry-level physical therapy students: anatomy and clinical examination of the dorsal column-medial lemniscal system.

    PubMed

    McKeough, D Michael; Mattern-Baxter, Katrin; Barakatt, Edward

    2010-01-01

    The purpose of this study was to determine if a computer-aided instruction learning module improves students' knowledge of the neuroanatomy/physiology and clinical examination of the dorsal column-medial lemniscal (DCML) system. Sixty-one physical therapy students enrolled in a clinical neurology course in entry-level PT educational programs at two universities participated in the study. Students from University-1 (U1;) had not had a previous neuroanatomy course, while students from University-2 (U2;) had taken a neuroanatomy course in the previous semester. Before and after working with the learning module, students took a paper-and-pencil test on the neuroanatomy/physiology and clinical examination of the DCML system. Kruskal-Wallis one-way ANOVA and Mann-Whitney tests were used to determine if differences existed between neuroanatomy/physiology examination scores and clinical examination scores before and after taking the learning module, and between student groups based on university attended. For students from U1, neuroanatomy/physiology post-test scores improved significantly over pre-test scores (p < 0.001), while post-test scores of students from U2 did not (p = 0.60). Neuroanatomy/physiology pre-test scores from U2 were significantly better than those from U1 (p < 0.001); there was no significant difference in post-test scores (p = 0.062). Clinical examination pre-test and post-test scores from U2 were significantly better than those from U1 (p < 0.001). Clinical examination post-test scores improved significantly from the pre-test scores for both U1 (p < 0.001) and U2 (p < 0.001).

  10. Development of expert system for biobased polymer material selection: food packaging application.

    PubMed

    Sanyang, M L; Sapuan, S M

    2015-10-01

    Biobased food packaging materials are gaining more attention owing to their intrinsic biodegradable nature and renewability. Selection of suitable biobased polymers for food packaging applications could be a tedious task with potential mistakes in choosing the best materials. In this paper, an expert system was developed using Exsys Corvid software to select suitable biobased polymer materials for packaging fruits, dry food and dairy products. If - Then rule based system was utilized to accomplish the material selection process whereas a score system was formulated to facilitate the ranking of selected materials. The expert system selected materials that satisfied all constraints and selection results were presented in suitability sequence depending on their scores. The expert system selected polylactic acid (PLA) as the most suitable material.

  11. The correlation between brain gray matter volume and empathizing and systemizing quotients in healthy children.

    PubMed

    Sassa, Yuko; Taki, Yasuyuki; Takeuchi, Hikaru; Hashizume, Hiroshi; Asano, Michiko; Asano, Kohei; Wakabayashi, Akio; Kawashima, Ryuta

    2012-05-01

    The abilities to empathize and to systemize, two fundamental dimensions of cognitive style, are characterized by apparent individual differences. These abilities are typically measured using an empathizing quotient (EQ) and a systemizing quotient (SQ) questionnaire, respectively. The purpose of this study was to reveal any correlations between EQ and SQ scores and regional gray matter volumes in healthy children by applying voxel-based morphometry to magnetic resonance images. We collected MRIs of brain structure and administered children's versions of the EQ and SQ questionnaires (EQ-C and SQ-C, respectively) to 261 healthy children aged 5-15 years. Structural MRI data were segmented, normalized, and smoothed using an optimized voxel-based morphometric analysis. Next, we analyzed the correlation between regional gray matter volume and EQ-C and SQ-C scores adjusting for age, sex, and intracranial volume. The EQ-C scores showed significant positive correlations with the regional gray matter volumes of the left fronto-opercular and superior temporal cortices, including the precentral gyrus, the inferior frontal gyrus, the superior temporal gyrus, and the insula, which are functionally related to empathic processing. Additionally, SQ-C scores showed a significant negative correlation with the regional gray matter volume of the left posterior parietal cortex, which is functionally involved in selective attention processing. Our findings suggest that individual differences in cognitive style pertaining to empathizing or systemizing abilities could be explained by differences in the volume of brain structures that are functionally relevant to empathizing and systemizing. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Derivation and Evaluation of a Risk-Scoring Tool to Predict Participant Attrition in a Lifestyle Intervention Project.

    PubMed

    Jiang, Luohua; Yang, Jing; Huang, Haixiao; Johnson, Ann; Dill, Edward J; Beals, Janette; Manson, Spero M; Roubideaux, Yvette

    2016-05-01

    Participant attrition in clinical trials and community-based interventions is a serious, common, and costly problem. In order to develop a simple predictive scoring system that can quantify the risk of participant attrition in a lifestyle intervention project, we analyzed data from the Special Diabetes Program for Indians Diabetes Prevention Program (SDPI-DP), an evidence-based lifestyle intervention to prevent diabetes in 36 American Indian and Alaska Native communities. SDPI-DP participants were randomly divided into a derivation cohort (n = 1600) and a validation cohort (n = 801). Logistic regressions were used to develop a scoring system from the derivation cohort. The discriminatory power and calibration properties of the system were assessed using the validation cohort. Seven independent factors predicted program attrition: gender, age, household income, comorbidity, chronic pain, site's user population size, and average age of site staff. Six factors predicted long-term attrition: gender, age, marital status, chronic pain, site's user population size, and average age of site staff. Each model exhibited moderate to fair discriminatory power (C statistic in the validation set: 0.70 for program attrition, and 0.66 for long-term attrition) and excellent calibration. The resulting scoring system offers a low-technology approach to identify participants at elevated risk for attrition in future similar behavioral modification intervention projects, which may inform appropriate allocation of retention resources. This approach also serves as a model for other efforts to prevent participant attrition.

  13. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Identification and Evaluation of Medical Translator Mobile Applications Using an Adapted APPLICATIONS Scoring System.

    PubMed

    Khander, Amrin; Farag, Sara; Chen, Katherine T

    2017-12-22

    With an increasing number of patients requiring translator services, many providers are turning to mobile applications (apps) for assistance. However, there have been no published reviews of medical translator apps. To identify and evaluate medical translator mobile apps using an adapted APPLICATIONS scoring system. A list of apps was identified from the Apple iTunes and Google Play stores, using the search term, "medical translator." Apps not found on two different searches, not in an English-based platform, not used for translation, or not functional after purchase, were excluded. The remaining apps were evaluated using an adapted APPLICATIONS scoring system, which included both objective and subjective criteria. App comprehensiveness was a weighted score defined by the number of non-English languages included in each app relative to the proportion of non-English speakers in the United States. The Apple iTunes and Google Play stores. Medical translator apps identified using the search term "medical translator." Main Outcomes and Measures: Compilation of medical translator apps for provider usage. A total of 524 apps were initially found. After applying the exclusion criteria, 20 (8.2%) apps from the Google Play store and 26 (9.2%) apps from the Apple iTunes store remained for evaluation. The highest scoring apps, Canopy Medical Translator, Universal Doctor Speaker, and Vocre Translate, scored 13.5 out of 18.7 possible points. A large proportion of apps initially found did not function as medical translator apps. Using the APPLICATIONS scoring system, we have identified and evaluated medical translator apps for providers who care for non-English speaking patients.

  15. The use of standardized patients in the plastic surgery residency curriculum: teaching core competencies with objective structured clinical examinations.

    PubMed

    Davis, Drew; Lee, Gordon

    2011-07-01

    As of 2006, the Accreditation Council for Graduate Medical Education had defined six "core competencies" of residency education: interpersonal communication skills, medical knowledge, patient care, professionalism, practice-based learning and improvement, and systems-based practice. Objective structured clinical examinations using standardized patients are becoming effective educational tools, and the authors developed a novel use of the examinations in plastic surgery residency education that assesses all six competencies. Six plastic surgery residents, two each from postgraduate years 4, 5, and 6, participated in the plastic surgery-specific objective structured clinical examination that focused on melanoma. The examination included a 30-minute videotaped encounter with a standardized patient actor and a postencounter written exercise. The residents were scored on their performance in all six core competencies by the standardized patients and faculty experts on a three-point scale (1 = novice, 2 = moderately skilled, and 3 = proficient). Resident performance was averaged for each postgraduate year, stratified according to core competency, and scored from a total of 100 percent. Residents overall scored well in interpersonal communications skills (84 percent), patient care (83 percent), professionalism (86 percent), and practice-based learning (84 percent). Scores in medical knowledge showed a positive correlation with level of training (86 percent). All residents scored comparatively lower in systems-based practice (65 percent). The residents reported unanimously that the objective structured clinical examination was realistic and educational. The objective structured clinical examination provided comprehensive and meaningful feedback and identified areas of strengths and weakness for the residents and for the teaching program. The examination is an effective assessment tool for the core competencies and a valuable adjunct to residency training.

  16. Evaluation of an inflammation-based prognostic score (GPS) in patients with metastatic breast cancer.

    PubMed

    Al Murri, A M; Bartlett, J M S; Canney, P A; Doughty, J C; Wilson, C; McMillan, D C

    2006-01-30

    Prediction of outcome in patients with metastatic breast cancer remains problematical. The present study evaluated the value of an inflammation-based score (Glasgow Prognostic Score, GPS) in patients with metastatic breast cancer. The GPS was constructed as follows: patients with both an elevated C-reactive protein (>10 mg l(-1)) and hypoalbuminaemia (<35 g l(-1)) were allocated a score of 2. Patients in whom only one or none of these biochemical abnormalities was present were allocated a score of 1 or 0, respectively. In total, 96 patients were studied. During follow-up 51 patients died of their cancer. On multivariate analysis of the GPS and treatment received, only the GPS (HR 2.26, 95% CI 1.45-3.52, P<0.001) remained significantly associated with cancer-specific survival. The presence of a systemic inflammatory response (the GPS) appears to be a useful indicator of poor outcome independent of treatment in patients with metastatic breast cancer.

  17. Improving Emergency Department Triage Classification with Computerized Clinical Decision Support at a Pediatric Hospital

    ERIC Educational Resources Information Center

    Kunisch, Joseph Martin

    2012-01-01

    Background: The Emergency Severity Index (ESI) is an emergency department (ED) triage classification system based on estimated patient-specific resource utilization. Rules for a computerized clinical decision support (CDS) system based on a patient's chief complaint were developed and tested using a stochastic model for predicting ESI scores.…

  18. Impact of a new simplified disability scoring system for adult patients with localized scleroderma.

    PubMed

    Okiyama, Naoko; Asano, Yoshihide; Hamaguchi, Yasuhito; Jinnin, Masatoshi; Motegi, Sei-Ichiro; Koizumi, Haruka; Hasegawa, Minoru; Ishikawa, Osamu; Sato, Shinichi; Takehara, Kazuhiko; Yamamoto, Toshiyuki; Fujimoto, Manabu; Ihn, Hironobu

    2018-04-01

    Localized scleroderma (LoS) involves dermal but not internal inflammation and fibrosis. Cosmetic changes often impact quality of life (QOL), however, impairment of activities of daily living (ADL) in LoS patients has not been investigated. To determine what factor(s) are associated with ADL in adult patients with LoS, we performed a retrospective observational study in 177 Japanese adult LoS patients using a novel LoS disability score based on Barthel's indices of ADL: feeding, bathing, grooming, dressing, bowels, bladder, toilet use, transfers, mobility and stairs. LoS disability scores increased in proportion to the number of affected body parts but were not correlated to age and duration of illness. The presence of leg lesions significantly impaired ADL of LoS patients compared with lesions on other body parts. Patients treated with systemic medications, who tended to have multiple lesions, presented higher LoS disability scores than those without systemic treatments. Our study proposes that physicians evaluate ADL, not only QOL, in LoS patients. Our findings using LoS disability scoring indicate that multiple affected body parts and leg lesions are risk factors for ADL impairment. © 2018 Japanese Dermatological Association.

  19. Promoting Systems Thinking through Biology Lessons

    NASA Astrophysics Data System (ADS)

    Riess, Werner; Mischo, Christoph

    2010-04-01

    This study's goal was to analyze various teaching approaches within the context of natural science lessons, especially in biology. The main focus of the paper lies on the effectiveness of different teaching methods in promoting systems thinking in the field of Education for Sustainable Development. The following methods were incorporated into the study: special lessons designed to promote systems thinking, a computer-simulated scenario on the topic "ecosystem forest," and a combination of both special lessons and the computer simulation. These groups were then compared to a control group. A questionnaire was used to assess systems thinking skills of 424 sixth-grade students of secondary schools in Germany. The assessment differentiated between a conceptual understanding (measured as achievement score) and a reflexive justification (measured as justification score) of systems thinking. The following control variables were used: logical thinking, grades in school, memory span, and motivational goal orientation. Based on the pretest-posttest control group design, only those students who received both special instruction and worked with the computer simulation showed a significant increase in their achievement scores. The justification score increased in the computer simulation condition as well as in the combination of computer simulation and lesson condition. The possibilities and limits of promoting various forms of systems thinking by using realistic computer simulations are discussed.

  20. Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations.

    PubMed

    Barili, Fabio; Pacini, Davide; D'Ovidio, Mariangela; Ventura, Martina; Alamanni, Francesco; Di Bartolomeo, Roberto; Grossi, Claudio; Davoli, Marina; Fusco, Danilo; Perucci, Carlo; Parolari, Alessandro

    2016-02-01

    Contemporary scores for estimating perioperative death have been proposed to also predict also long-term death. The aim of the study was to evaluate the performance of the updated European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons Predicted Risk of Mortality score, and the Age, Creatinine, Left Ventricular Ejection Fraction score for predicting long-term mortality in a contemporary cohort of isolated aortic valve replacement (AVR). We also sought to develop for each score a simple algorithm based on predicted perioperative risk to predict long-term survival. Complete data on 1,444 patients who underwent isolated AVR in a 7-year period were retrieved from three prospective institutional databases and linked with the Italian Tax Register Information System. Data were evaluated with performance analyses and time-to-event semiparametric regression. Survival was 83.0% ± 1.1% at 5 years and 67.8 ± 1.9% at 8 years. Discrimination and calibration of all three scores both worsened for prediction of death at 1 year and 5 years. Nonetheless, a significant relationship was found between long-term survival and quartiles of scores (p < 0.0001). The estimated perioperative risk by each model was used to develop an algorithm to predict long-term death. The hazard ratios for death were 1.1 (95% confidence interval, 1.07 to 1.12) for European System for Cardiac Operative Risk Evaluation II, 1.34 (95% CI, 1.28 to 1.40) for the Society of Thoracic Surgeons score, and 1.08 (95% CI, 1.06 to 1.10) for the Age, Creatinine, Left Ventricular Ejection Fraction score. The predicted risk generated by European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons score, and Age, Creatinine, Left Ventricular Ejection Fraction scores cannot also be considered a direct estimate of the long-term risk for death. Nonetheless, the three scores can be used to derive an estimate of long-term risk of death in patients who undergo isolated AVR with the use of a simple algorithm. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. A Method to Calculate and Analyze Residents' Evaluations by Using a Microcomputer Data-Base Management System.

    ERIC Educational Resources Information Center

    Mills, Myron L.

    1988-01-01

    A system developed for more efficient evaluation of graduate medical students' progress uses numerical scoring and a microcomputer database management system as an alternative to manual methods to produce accurate, objective, and meaningful summaries of resident evaluations. (Author/MSE)

  2. Clinical Inquiry: What's the best way to predict the success of a trial of labor after a previous C-section?

    PubMed

    Warren, Johanna B; Hamilton, Andrew

    2015-12-01

    Seven validated prospective scoring systems, and one unvalidated system, predict a successful TOLAC based on a variety of clinical factors. The systems use different outcome statistics, so their predictive accuracy can't be directly compared.

  3. Automated Error Detection in Physiotherapy Training.

    PubMed

    Jovanović, Marko; Seiffarth, Johannes; Kutafina, Ekaterina; Jonas, Stephan M

    2018-01-01

    Manual skills teaching, such as physiotherapy education, requires immediate teacher feedback for the students during the learning process, which to date can only be performed by expert trainers. A machine-learning system trained only on correct performances to classify and score performed movements, to identify sources of errors in the movement and give feedback to the learner. We acquire IMU and sEMG sensor data from a commercial-grade wearable device and construct an HMM-based model for gesture classification, scoring and feedback giving. We evaluate the model on publicly available and self-generated data of an exemplary movement pattern executions. The model achieves an overall accuracy of 90.71% on the public dataset and 98.9% on our dataset. An AUC of 0.99 for the ROC of the scoring method could be achieved to discriminate between correct and untrained incorrect executions. The proposed system demonstrated its suitability for scoring and feedback in manual skills training.

  4. Median Growth Percentiles (MGPs): Assessment of Intertemporal Stability and Correlations with Observational Scores

    ERIC Educational Resources Information Center

    Pivovarova, Margarita; Amrein-Beardsley, Audrey

    2018-01-01

    While states are no longer required to set up teacher evaluation systems based in significant part on student test scores, quite a few continue to use value-added (VAMs) or student growth percentile (SGP) models for that purpose. In this study, we analyzed three years of teacher data to illustrate the performance of teachers' median growth…

  5. What Works Clearinghouse Quick Review: "Incentives, Selection, and Teacher Performance: Evidence from IMPACT"

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2013

    2013-01-01

    This study examined the effect of IMPACT on teacher retention and performance. IMPACT is a high-stakes teacher evaluation system used in the District of Columbia public schools that gives teachers scores reflecting their performance in the classroom and the achievement of their students. Based on these scores, teachers were assigned to one of four…

  6. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group.

    PubMed

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A N; Lübbert, Michael; Greenberg, Peter L; Bennett, John M; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L; Ohyashiki, Kazuma; Le Beau, Michelle M; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-02-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%-20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34(+)) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34(+) peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34(+) blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). Copyright© Ferrata Storti Foundation.

  7. Diagnosing Appendicitis: Evidence-Based Review of the Diagnostic Approach in 2014

    PubMed Central

    Shogilev, Daniel J.; Duus, Nicolaj; Odom, Stephen R.; Shapiro, Nathan I.

    2014-01-01

    Introduction Acute appendicitis is the most common abdominal emergency requiring emergency surgery. However, the diagnosis is often challenging and the decision to operate, observe or further work-up a patient is often unclear. The utility of clinical scoring systems (namely the Alvarado score), laboratory markers, and the development of novel markers in the diagnosis of appendicitis remains controversial. This article presents an update on the diagnostic approach to appendicitis through an evidence-based review. Methods We performed a broad Medline search of radiological imaging, the Alvarado score, common laboratory markers, and novel markers in patients with suspected appendicitis. Results Computed tomography (CT) is the most accurate mode of imaging for suspected cases of appendicitis, but the associated increase in radiation exposure is problematic. The Alvarado score is a clinical scoring system that is used to predict the likelihood of appendicitis based on signs, symptoms and laboratory data. It can help risk stratify patients with suspected appendicitis and potentially decrease the use of CT imaging in patients with certain Alvarado scores. White blood cell (WBC), C-reactive protein (CRP), granulocyte count and proportion of polymorphonuclear (PMN) cells are frequently elevated in patients with appendicitis, but are insufficient on their own as a diagnostic modality. When multiple markers are used in combination their diagnostic utility is greatly increased. Several novel markers have been proposed to aid in the diagnosis of appendicitis; however, while promising, most are only in the preliminary stages of being studied. Conclusion While CT is the most accurate mode of imaging in suspected appendicitis, the accompanying radiation is a concern. Ultrasound may help in the diagnosis while decreasing the need for CT in certain circumstances. The Alvarado Score has good diagnostic utility at specific cutoff points. Laboratory markers have very limited diagnostic utility on their own but show promise when used in combination. Further studies are warranted for laboratory markers in combination and to validate potential novel markers. PMID:25493136

  8. Multiattribute health utility scoring for the computerized adaptive measure CAT-5D-QOL was developed and validated.

    PubMed

    Kopec, Jacek A; Sayre, Eric C; Rogers, Pamela; Davis, Aileen M; Badley, Elizabeth M; Anis, Aslam H; Abrahamowicz, Michal; Russell, Lara; Rahman, Md Mushfiqur; Esdaile, John M

    2015-10-01

    The CAT-5D-QOL is a previously reported item response theory (IRT)-based computerized adaptive tool to measure five domains (attributes) of health-related quality of life. The objective of this study was to develop and validate a multiattribute health utility (MAHU) scoring method for this instrument. The MAHU scoring system was developed in two stages. In phase I, we obtained standard gamble (SG) utilities for 75 hypothetical health states in which only one domain varied (15 states per domain). In phase II, we obtained SG utilities for 256 multiattribute states. We fit a multiplicative regression model to predict SG utilities from the five IRT domain scores. The prediction model was constrained using data from phase I. We validated MAHU scores by comparing them with the Health Utilities Index Mark 3 (HUI3) and directly measured utilities and by assessing between-group discrimination. MAHU scores have a theoretical range from -0.842 to 1. In the validation study, the scores were, on average, higher than HUI3 utilities and lower than directly measured SG utilities. MAHU scores correlated strongly with the HUI3 (Spearman ρ = 0.78) and discriminated well between groups expected to differ in health status. Results reported here provide initial evidence supporting the validity of the MAHU scoring system for the CAT-5D-QOL. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Facial Aesthetic Outcomes of Cleft Surgery: Assessment of Discrete Lip and Nose Images Compared with Digital Symmetry Analysis.

    PubMed

    Deall, Ciara E; Kornmann, Nirvana S S; Bella, Husam; Wallis, Katy L; Hardwicke, Joseph T; Su, Ting-Li; Richard, Bruce M

    2016-10-01

    High-quality aesthetic outcomes are of paramount importance to children growing up after cleft lip and palate surgery. Establishing a validated and reliable assessment tool for cleft professionals and families will facilitate cleft units, surgeons, techniques, and protocols to be audited and compared with greater confidence. This study used exemplar images across a five-point aesthetic scale, identified in a pilot project, to score lips and noses as separate units and compared these human scores with computer-based SymNose symmetry scores. Forty-five assessors (17 cleft surgeons nationally and 28 other cleft professionals from the UK South West Tri-centre units), scored 25 standardized photographs, uploaded randomly onto a Web-based platform, twice. Each photograph was shown in three forms: lip and nose together, and separately cropped images of nose only and lip only. The same images were analyzed using the SymNose software program. Scoring lips gave the best intrarater and interrater reliabilities. Nose scores were more variable. Lip scoring associated most closely with the whole-image score. SymNose ranking of the lip images related highly to the same ranking by humans (p = 0.001). The exemplar images maintained their established previous ranking. Images illustrating the aesthetic outcome grades are confirmed. The lip score is reliable and seems to dominate in the whole-image score. Noses are much harder to score reliably. It appears that SymNose can score lip images very effectively by symmetry. Further use of SymNose will be investigated, and families of children with cleft will trial the scoring system. Therapeutic, III.

  10. Assessment of fatty degeneration of the gluteal muscles in patients with THA using MRI: reliability and accuracy of the Goutallier and quartile classification systems.

    PubMed

    Engelken, Florian; Wassilew, Georgi I; Köhlitz, Torsten; Brockhaus, Sebastian; Hamm, Bernd; Perka, Carsten; Diederichs, und Gerd

    2014-01-01

    The purpose of this study was to quantify the performance of the Goutallier classification for assessing fatty degeneration of the gluteus muscles from magnetic resonance (MR) images and to compare its performance to a newly proposed system. Eighty-four hips with clinical signs of gluteal insufficiency and 50 hips from asymptomatic controls were analyzed using a standard classification system (Goutallier) and a new scoring system (Quartile). Interobserver reliability and intraobserver repeatability were determined, and accuracy was assessed by comparing readers' scores with quantitative estimates of the proportion of intramuscular fat based on MR signal intensities (gold standard). The existing Goutallier classification system and the new Quartile system performed equally well in assessing fatty degeneration of the gluteus muscles, both showing excellent levels of interrater and intrarater agreement. While the Goutallier classification system has the advantage of being widely known, the benefit of the Quartile system is that it is based on more clearly defined grades of fatty degeneration. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. A risk prediction model for determining appropriateness of CEA in patients with asymptomatic carotid artery stenosis.

    PubMed

    Conrad, Mark F; Kang, Jeanwan; Mukhopadhyay, Shankha; Patel, Virendra I; LaMuraglia, Glenn M; Cambria, Richard P

    2013-10-01

    The benefit of carotid endarterectomy (CEA) over medical therapy in patients with asymptomatic carotid artery stenosis is predicated upon a life expectancy of at least 5 years after the procedure. The goal of this study was to create a scoring system for prediction of 5-year survival after CEA that can be used to triage patients with ACAS. All patients who underwent CEA for severe asymptomatic carotid stenosis from 1989 to 2005 were identified. Long-term survival was determined by a review of hospital records and the social security death index. Because all patients had at least 5-year follow-up, a logistic regression of predictors of survival at 5 years was performed and the odds ratios associated with particular significant comorbidities were used to create a scoring system to predict survival. The scoring system was then validated within the cohort using the Hosmer-Lemeshow Test and a derivation/validation receiver operating characteristic (ROC) curve. There were 2004 CEA performed in 1791 patients. The average follow-up was 130 ± 49 months. The clinical profile of the cohort data included 84% hypertension, 56% coronary artery disease (CAD), 24% diabetes, and 71% on statins. The 30-day stroke rate was 1.1% and the death rate was 0.7%. The actual 5-year survival was 73%. Logistic regression yielded the following predictors of mortality: age (by decade) (odds ratio [OR] = 1.8, P < 0.0001), CAD (OR = 1.5, P = 0.0007), chronic obstructive pulmonary disease (OR = 2.5; P < 0.0001), diabetes (OR = 1.7, P < 0.0001), neck radiation (OR = 2.6, P = 0.005), no statin (OR = 2.1, P < 0.0001), and creatinine more than 1.5 (OR = 2.6, P < 0.0001). These variables were then assigned a hierarchal point scoring system in accordance with the OR value. The 5-year survival based on the scoring system was as follows: 0 to 5 points = 92.5%, 6 to 8 points = 83.6%, 9 to 11 points = 63.7%, 12 to 14 points = 46.5%, and more than 15 points = 33.8%. The Hosmer-Lemeshow test validated the scoring system (P = 0.26) and there was no difference in the ROC curves (C statistic = 0.74 vs 0.73). This validated scoring system can be a useful tool for determining which patients are likely to benefit most from CEA based on the probability of long-term survival. Given that the 5-year survival of patients in the medical arm of the asymptomatic CEA trials was 60% to 70%, it is reasonable to conclude that patients who score 0 to 8 points are excellent candidates for CEA whereas most patients with ≥12 points should be managed with medical therapy alone.

  12. Resources, indicators, data management, dissemination and use in health information systems in sub-Saharan Africa: results of a questionnaire-based survey.

    PubMed

    Mbondji, Peter Ebongue; Kebede, Derege; Soumbey-Alley, Edoh William; Zielinski, Chris; Kouvividila, Wenceslas; Lusamba-Dikassa, Paul-Samson

    2014-05-01

    To describe the status of health information systems in 14 sub-Saharan African countries of the World Health Organization African Region. A questionnaire-based survey. Fourteen sub-Saharan African countries of the African Region. Key informants in the ministries of health, national statistics offices, health programmes, donors and technical agencies. State of resources, indicators, data sources, data management, information products, dissemination and use of health information. The highest average score was in the identification and harmonisation of indicators (73%), reflecting successful efforts to identify priority indicators and reach international consensus on indicators for several diseases. This was followed by information products (63%), which indicated the availability of accurate and reliable data. The lowest score (41%) was in data management, the ability to collect, store, analyse and distribute data, followed by resources - policy and planning, human and financial resources, and infrastructure (53%). Data sources (e.g. censuses, surveys) were on average inadequate with a score of 56%. The average score for dissemination and use of health information was 57%, which indicated limited or inadequate use of data for advocacy, planning and decision-making. National health information systems are weak in the surveyed countries and much more needs to be done to improve the quality and relevance of data, and their management, sharing and use for policy-making and decision-making. © The Royal Society of Medicine.

  13. Development of a partial least squares-artificial neural network (PLS-ANN) hybrid model for the prediction of consumer liking scores of ready-to-drink green tea beverages.

    PubMed

    Yu, Peigen; Low, Mei Yin; Zhou, Weibiao

    2018-01-01

    In order to develop products that would be preferred by consumers, the effects of the chemical compositions of ready-to-drink green tea beverages on consumer liking were studied through regression analyses. Green tea model systems were prepared by dosing solutions of 0.1% green tea extract with differing concentrations of eight flavour keys deemed to be important for green tea aroma and taste, based on a D-optimal experimental design, before undergoing commercial sterilisation. Sensory evaluation of the green tea model system was carried out using an untrained consumer panel to obtain hedonic liking scores of the samples. Regression models were subsequently trained to objectively predict the consumer liking scores of the green tea model systems. A linear partial least squares (PLS) regression model was developed to describe the effects of the eight flavour keys on consumer liking, with a coefficient of determination (R 2 ) of 0.733, and a root-mean-square error (RMSE) of 3.53%. The PLS model was further augmented with an artificial neural network (ANN) to establish a PLS-ANN hybrid model. The established hybrid model was found to give a better prediction of consumer liking scores, based on its R 2 (0.875) and RMSE (2.41%). Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Multi-institutional validation of a web-based core competency assessment system.

    PubMed

    Tabuenca, Arnold; Welling, Richard; Sachdeva, Ajit K; Blair, Patrice G; Horvath, Karen; Tarpley, John; Savino, John A; Gray, Richard; Gulley, Julie; Arnold, Teresa; Wolfe, Kevin; Risucci, Donald A

    2007-01-01

    The Association of Program Directors in Surgery and the Division of Education of the American College of Surgeons developed and implemented a web-based system for end-of-rotation faculty assessment of ACGME core competencies of residents. This study assesses its reliability and validity across multiple programs. Each assessment included ratings (1-5 scale) on 23 items reflecting the 6 core competencies. A total of 4241 end-of-rotation assessments were completed for 332 general surgery residents (> or =5 evaluations each) at 5 sites during the 2004-2005 and 2005-2006 academic years. The mean rating for each resident on each item was computed for each academic year. The mean rating of items representing each competency was computed for each resident. Additional data included USMLE and ABSITE scores, PGY, and status in program (categorical, designated preliminary, and undesignated preliminary). Coefficient alpha was greater than 0.90 for each competency score. Mean ratings for each competency increased significantly (p < 0.01) as a function of PGY. Mean ratings for professionalism and interpersonal/communication skills (IPC) were significantly higher than all other competencies at all PGY levels. Competency ratings of PGY 1 residents correlated significantly with USMLE Step I, ranging from (r = 0.26, p < 0.01) for Professionalism to (r = 0.41, p < 0.001) for Systems-Based Practice. Ratings of Knowledge (r = 0.31, p < 0.01), Practice-Based Learning & Improvement (PBLI; r = 0.22, p < 0.05), and Systems-Based Practice (r = 0.20, p < 0.05) correlated significantly with 2005 ABSITE Total Percentile. Ratings of all competencies correlated significantly with the 2006 ABSITE Total Percentile Score (range: r = 0.20, p < 0.05 for professionalism to r = 0.35, p < 0.001 for knowledge). Categorical and designated preliminary residents received significantly higher ratings (p < 0.05) than nondesignated preliminaries for knowledge, patient care, PBLI, and systems-based practice only. Faculty ratings of core competencies are internally consistent. The pattern of statistically significant correlations between competency ratings and USMLE and ABSITE scores supports the postdictive and concurrent validity, respectively, of faculty perceptions of resident knowledge. The pattern of increased ratings as a function of PGY supports the construct validity of faculty ratings of resident core competencies.

  15. Time Burden of Standardized Hip Questionnaires.

    PubMed

    Chughtai, Morad; Khlopas, Anton; Mistry, Jaydev B; Gwam, Chukwuweike U; Elmallah, Randa K; Mont, Michael A

    2016-04-01

    Many standardized scales and questionnaires have been developed to assess outcomes of patients undergoing total hip arthroplasty (THA). However, these surveys can be a burden to both patients and orthopaedists as some are time-inefficient. In addition, there is a paucity of reports assessing the time it takes to complete them. In this study we aimed to: (1) assess how long it takes to complete the most common standardized hip questionnaires; (2) determine the presence of variation in completion time; and (3) evaluate the effects of age, gender, and level of education on completion time. Based on a previous study, we selected the seven most commonly used hip scoring systems-Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), Larson Score, Short-form 36 (SF-36), modified Merle d'Aubigne and Postel Score (MDA), and Lower Extremity Functional Scale (LEFS). The standardized scales and questionnaires were randomly administered to 70 subjects. The subjects were unaware that they were being timed during completion of the questionnaire. We obtained the coefficients of variation of time for each questionnaire. The mean time to complete the questionnaire was then stratified and compared based on age, gender, and level of education. The mean time to complete each of the systems is listed in ascending order: Modified Merle d'Aubigne and Postel Score (MDA), Lower Extremity Functional Scale (LEFS), Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Larson Score, Hip Disability and Osteoarthritis Outcome Score (HOOS), and Short-form 36 (SF-36). The WOMAC and Larson Score coefficients of variation were the largest, and the HOOS and MDA were the smallest. There was a significantly higher mean time to completion in those who were above or equal to the age of 55 years as compared to those who were below the age of 55 (227 vs. 166 seconds). There was no significant association found in time of completion between gender or education level. Standardized scales and questionnaire which assess THA patients can be burdensome and time-inefficient, which may lead to task-induced fatigue. This may result in inaccurate THA patient assessments, which do not reflect the patient's true state. Future studies should aim to create an encompassing questionnaire that is time efficient and can replace all currently used validated systems.

  16. Animal-Based Measures to Assess the Welfare of Extensively Managed Ewes

    PubMed Central

    Hemsworth, Paul; Doyle, Rebecca

    2017-01-01

    Simple Summary The aim of this study was to assess the reliability and practicality of 10 animal-based welfare measures for extensively managed ewes, which were derived from the scientific literature, previous welfare protocols and through consultation with veterinarians and animal welfare scientists. Measures were examined on 100 Merino ewes, which were individually identified and repeatedly examined at mid-pregnancy, mid-lactation and weaning. Body condition score, fleece condition, skin lesions, tail length, dag score and lameness are proposed for on-farm use in welfare assessments of extensive sheep production systems. These six welfare measures, which address the main welfare concerns for extensively managed ewes, can be reliably and feasibly measured in the field. Abstract The reliability and feasibility of 10 animal-based measures of ewe welfare were examined for use in extensive sheep production systems. Measures were: Body condition score (BCS), rumen fill, fleece cleanliness, fleece condition, skin lesions, tail length, dag score, foot-wall integrity, hoof overgrowth and lameness, and all were examined on 100 Merino ewes (aged 2–4 years) during mid-pregnancy, mid-lactation and weaning by a pool of nine trained observers. The measures of BCS, fleece condition, skin lesions, tail length, dag score and lameness were deemed to be reliable and feasible. All had good observer agreement, as determined by the percentage of agreement, Kendall’s coefficient of concordance (W) and Kappa (k) values. When combined, these nutritional and health measures provide a snapshot of the current welfare status of ewes, as well as evidencing previous or potential welfare issues. PMID:29295551

  17. Posterior Urethroplasty Complexity and Prognosis Can be Described by a Novel Method: Posterior Urethral Stenosis Score.

    PubMed

    Wang, Lin; Lv, Xiangguo; Jin, Chongrui; Guo, Hailin; Shu, Huiquan; Fu, Qiang; Sa, Yinglong

    2018-02-01

    To develop a standardized PU-score (posterior urethral stenosis score), with the goal of using this scoring system as a preliminary predictor of surgical complexity and prognosis of posterior urethral stenosis. We retrospectively reviewed records of all patients who underwent posterior urethral surgery at our institution from 2013 to 2015. The PU-score is based on 5 components, namely etiology (1 or 2 points), location (1-3 points), length (1-3 points), urethral fistula (1 or 2 points), and posterior urethral false passage (1 point). We calculated the score of all patients and analyzed its association with surgical complexity, stenosis recurrence, intraoperative blood loss, erectile dysfunction, and urinary incontinence. There were 144 patients who underwent low complexity urethral surgery (direct vision internal urethrotomy, anastomosis with or without crural separation) with a mean score of 5.1 points, whereas 143 underwent high complexity urethroplasty (anastomosis with inferior pubectomy or urethrorectal fistula repair, perineal or scrotum skin flap urethroplasty, bladder flap urethroplasty) with a mean score of 6.9 points. The increase of PU-score was predictive of higher surgical complexity (P = .000), higher recurrence (P = .002), more intraoperative blood loss (P = .000), and decrease of preoperative (P = .037) or postoperative erectile function (P = .047). However, no association was observed between PU-score and urinary incontinence (P = .213). The PU-score is a novel and meaningful scoring system that describes the essential factors in determining the complexity and prognosis for posterior urethral stenosis. Copyright © 2017. Published by Elsevier Inc.

  18. Telemedicine-based system for quality management and peer review in radiology.

    PubMed

    Morozov, Sergey; Guseva, Ekaterina; Ledikhova, Natalya; Vladzymyrskyy, Anton; Safronov, Dmitry

    2018-06-01

    Quality assurance is the key component of modern radiology. A telemedicine-based quality assurance system helps to overcome the "scoring" approach and makes the quality control more accessible and objective. A concept for quality assurance in radiology is developed. Its realization is a set of strategies, actions, and tools. The latter is based on telemedicine-based peer review of 23,199 computed tomography (CT) and magnetic resonance imaging (MRI) images. The conception of the system for quality management in radiology represents a chain of actions: "discrepancies evaluation - routine support - quality improvement activity - discrepancies evaluation". It is realized by an audit methodology, telemedicine, elearning, and other technologies. After a year of systemic telemedicine-based peer reviews, the authors have estimated that clinically significant discrepancies were detected in 6% of all cases, while clinically insignificant ones were found in 19% of cases. Most often, problems appear in musculoskeletal records; 80% of the examinations have diagnostic or technical imperfections. The presence of routine telemedicine support and personalized elearning allowed improving the diagnostics quality. The level of discrepancies has decreased significantly (p < 0.05). The telemedicine-based peer review system allows improving radiology departments' network effectiveness. • "Scoring" approach to radiologists' performance assessment must be changed. • Telemedicine peer review and personalized elearning significantly decrease the number of discrepancies. • Teleradiology allows linking all primary-level hospitals to a common peer review network.

  19. Adding an alcohol-related risk score to an existing categorical risk classification for older adults: sensitivity to group differences.

    PubMed

    Wilson, Sandra R; Fink, Arlene; Verghese, Shinu; Beck, John C; Nguyen, Khue; Lavori, Philip

    2007-03-01

    To evaluate a new alcohol-related risk score for research use. Using data from a previously reported trial of a screening and education system for older adults (Computerized Alcohol-Related Problems Survey), secondary analyses were conducted comparing the ability of two different measures of risk to detect post-intervention group differences: the original categorical outcome measure and a new, finely grained quantitative risk score based on the same research-based risk factors. Three primary care group practices in southern California. Six hundred sixty-five patients aged 65 and older. A previously calculated, three-level categorical classification of alcohol-related risk and a newly developed quantitative risk score. Mean post-intervention risk scores differed between the three experimental conditions: usual care, patient report, and combined report (P<.001). The difference between the combined report and usual care was significant (P<.001) and directly proportional to baseline risk. The three-level risk classification did not reveal approximately 57.3% of the intervention effect detected by the risk score. The risk score also was sufficiently sensitive to detect the intervention effect within the subset of hypertensive patients (n=112; P=.001). As an outcome measure in intervention trials, the finely grained risk score is more sensitive than the trinary risk classification. The additional clinical value of the risk score relative to the categorical measure needs to be determined.

  20. A novel scoring system for gastric cancer risk assessment based on the expression of three CLIP4 DNA methylation-associated genes

    PubMed Central

    Hu, Chenggong; Zhou, Yongfang; Liu, Chang; Kang, Yan

    2018-01-01

    Gastric cancer (GC) is the fifth most common cancer and the third leading cause of cancer-associated mortality worldwide. In the current study, comprehensive bioinformatic analyses were performed to develop a novel scoring system for GC risk assessment based on CAP-Gly domain containing linker protein family member 4 (CLIP4) DNA methylation status. Two GC datasets with methylation sequencing information and mRNA expression profiling were downloaded from the The Cancer Genome Atlas and Gene Expression Omnibus databases. Differentially expressed genes (DEGs) between the CLIP4 hypermethylation and CLIP4 hypomethylation groups were screened using the limma package in R 3.3.1, and survival analysis of these DEGs was performed using the survival package. A risk scoring system was established via regression factor-weighted gene expression based on linear combination to screen the most important genes associated with CLIP4 methylation and prognosis. Genes associated with high/low-risk value were selected using the limma package. Functional enrichment analysis of the top 500 DEGs that positively and negatively associated with risk values was performed using DAVID 6.8 online and the gene set enrichment analysis (GSEA) software. In total, 35 genes were identified to be that significantly associated with prognosis and CLIP4 DNA methylation, and three prognostic signature genes, claudin-11 (CLDN11), apolipoprotein D (APOD), and chordin like 1 (CHRDL1), were used to establish a risk assessment system. The prognostic scoring system exhibited efficiency in classifying patients with different prognoses, where the low-risk groups had significantly longer overall survival times than those in the high-risk groups. CLDN11, APOD and CHRDL1 exhibited reduced expression in the hypermethylation and low-risk groups compare with the hypomethylation and high-risk groups, respectively. Multivariate Cox analysis indicated that risk value could be used as an independent prognostic factor. In functional analysis, six functional gene ontology terms and five GSEA pathways were associated with CLDN11, APOD and CHRDL1. The results established the credibility of the scoring system in this study. Additionally, these three genes, which were significantly associated with CLIP4 DNA methylation and GC risk assessment, were identified as potential prognostic biomarkers. PMID:29901187

  1. Physical therapy for facial paralysis: a tailored treatment approach.

    PubMed

    Brach, J S; VanSwearingen, J M

    1999-04-01

    Bell palsy is an acute facial paralysis of unknown etiology. Although recovery from Bell palsy is expected without intervention, clinical experience suggests that recovery is often incomplete. This case report describes a classification system used to guide treatment and to monitor recovery of an individual with facial paralysis. The patient was a 71-year-old woman with complete left facial paralysis secondary to Bell palsy. Signs and symptoms were assessed using a standardized measure of facial impairment (Facial Grading System [FGS]) and questions regarding functional limitations. A treatment-based category was assigned based on signs and symptoms. Rehabilitation involved muscle re-education exercises tailored to the treatment-based category. In 14 physical therapy sessions over 13 months, the patient had improved facial impairments (initial FGS score= 17/100, final FGS score= 68/100) and no reported functional limitations. Recovery from Bell palsy can be a complicated and lengthy process. The use of a classification system may help simplify the rehabilitation process.

  2. Validation of the Lupus Nephritis Clinical Indices in Childhood-Onset Systemic Lupus Erythematosus.

    PubMed

    Mina, Rina; Abulaban, Khalid; Klein-Gitelman, Marisa S; Eberhard, Barbara A; Ardoin, Stacy P; Singer, Nora; Onel, Karen; Tucker, Lori; O'neil, Kathleen; Wright, Tracey; Brooks, Elizabeth; Rouster-Stevens, Kelly; Jung, Lawrence; Imundo, Lisa; Rovin, Brad; Witte, David; Ying, Jun; Brunner, Hermine I

    2016-02-01

    To validate clinical indices of lupus nephritis activity and damage when used in children against the criterion standard of kidney biopsy findings. In 83 children requiring kidney biopsy, the Systemic Lupus Erythematosus Disease Activity Index renal domain (SLEDAI-R), British Isles Lupus Assessment Group index renal domain (BILAG-R), Systemic Lupus International Collaborating Clinics (SLICC) renal activity score (SLICC-RAS), and SLICC Damage Index renal domain (SDI-R) were measured. Fixed effects and logistic models were calculated to predict International Society of Nephrology/Renal Pathology Society (ISN/RPS) class; low-to-moderate versus high lupus nephritis activity (National Institutes of Health [NIH] activity index [AI]) score: ≤10 versus >10; tubulointerstitial activity index (TIAI) score: ≤5 versus >5; or the absence versus presence of lupus nephritis chronicity (NIH chronicity index) score: 0 versus ≥1. There were 10, 50, and 23 patients with ISN/RPS class I/II, III/IV, and V, respectively. Scores of the clinical indices did not differentiate among patients by ISN/RPS class. The SLEDAI-R and SLICC-RAS but not the BILAG-R differed with lupus nephritis activity status defined by NIH-AI scores, while only the SLEDAI-R scores differed between lupus nephritis activity status based on TIAI scores. The sensitivity and specificity of the SDI-R to capture lupus nephritis chronicity was 23.5% and 91.7%, respectively. Despite being designed to measure lupus nephritis activity, SLICC-RAS and SLEDAI-R scores significantly differed with lupus nephritis chronicity status. Current clinical indices of lupus nephritis fail to discriminate ISN/RPS class in children. Despite its shortcomings, the SLEDAI-R appears best for measuring lupus nephritis activity in a clinical setting. The SDI-R is a poor correlate of lupus nephritis chronicity. © 2016, American College of Rheumatology.

  3. Airborne Turbulence Detection System Certification Tool Set

    NASA Technical Reports Server (NTRS)

    Hamilton, David W.; Proctor, Fred H.

    2006-01-01

    A methodology and a corresponding set of simulation tools for testing and evaluating turbulence detection sensors has been presented. The tool set is available to industry and the FAA for certification of radar based airborne turbulence detection systems. The tool set consists of simulated data sets representing convectively induced turbulence, an airborne radar simulation system, hazard tables to convert the radar observable to an aircraft load, documentation, a hazard metric "truth" algorithm, and criteria for scoring the predictions. Analysis indicates that flight test data supports spatial buffers for scoring detections. Also, flight data and demonstrations with the tool set suggest the need for a magnitude buffer.

  4. Intelligibility in microbial complex systems: Wittgenstein and the score of life.

    PubMed

    Baquero, Fernando; Moya, Andrés

    2012-01-01

    Knowledge in microbiology is reaching an extreme level of diversification and complexity, which paradoxically results in a strong reduction in the intelligibility of microbial life. In our days, the "score of life" metaphor is more accurate to express the complexity of living systems than the classic "book of life." Music and life can be represented at lower hierarchical levels by music scores and genomic sequences, and such representations have a generational influence in the reproduction of music and life. If music can be considered as a representation of life, such representation remains as unthinkable as life itself. The analysis of scores and genomic sequences might provide mechanistic, phylogenetic, and evolutionary insights into music and life, but not about their real dynamics and nature, which is still maintained unthinkable, as was proposed by Wittgenstein. As complex systems, life or music is composed by thinkable and only showable parts, and a strategy of half-thinking, half-seeing is needed to expand knowledge. Complex models for complex systems, based on experiences on trans-hierarchical integrations, should be developed in order to provide a mixture of legibility and imageability of biological processes, which should lead to higher levels of intelligibility of microbial life.

  5. Intelligibility in microbial complex systems: Wittgenstein and the score of life

    PubMed Central

    Baquero, Fernando; Moya, Andrés

    2012-01-01

    Knowledge in microbiology is reaching an extreme level of diversification and complexity, which paradoxically results in a strong reduction in the intelligibility of microbial life. In our days, the “score of life” metaphor is more accurate to express the complexity of living systems than the classic “book of life.” Music and life can be represented at lower hierarchical levels by music scores and genomic sequences, and such representations have a generational influence in the reproduction of music and life. If music can be considered as a representation of life, such representation remains as unthinkable as life itself. The analysis of scores and genomic sequences might provide mechanistic, phylogenetic, and evolutionary insights into music and life, but not about their real dynamics and nature, which is still maintained unthinkable, as was proposed by Wittgenstein. As complex systems, life or music is composed by thinkable and only showable parts, and a strategy of half-thinking, half-seeing is needed to expand knowledge. Complex models for complex systems, based on experiences on trans-hierarchical integrations, should be developed in order to provide a mixture of legibility and imageability of biological processes, which should lead to higher levels of intelligibility of microbial life. PMID:22919679

  6. Decision analysis for a data collection system of patient-controlled analgesia with a multi-attribute utility model.

    PubMed

    Lee, I-Jung; Huang, Shih-Yu; Tsou, Mei-Yung; Chan, Kwok-Hon; Chang, Kuang-Yi

    2010-10-01

    Data collection systems are very important for the practice of patient-controlled analgesia (PCA). This study aimed to evaluate 3 PCA data collection systems and selected the most favorable system with the aid of multiattribute utility (MAU) theory. We developed a questionnaire with 10 items to evaluate the PCA data collection system and 1 item for overall satisfaction based on MAU theory. Three systems were compared in the questionnaire, including a paper record, optic card reader and personal digital assistant (PDA). A pilot study demonstrated a good internal and test-retest reliability of the questionnaire. A weighted utility score combining the relative importance of individual items assigned by each participant and their responses to each question was calculated for each system. Sensitivity analyses with distinct weighting protocols were conducted to evaluate the stability of the final results. Thirty potential users of a PCA data collection system were recruited in the study. The item "easy to use" had the highest median rank and received the heaviest mean weight among all items. MAU analysis showed that the PDA system had a higher utility score than that in the other 2 systems. Sensitivity analyses revealed that both inverse and reciprocal weighting processes favored the PDA system. High correlations between overall satisfaction and MAU scores from miscellaneous weighting protocols suggested a good predictive validity of our MAU-based questionnaire. The PDA system was selected as the most favorable PCA data collection system by the MAU analysis. The item "easy to use" was the most important attribute of the PCA data collection system. MAU theory can evaluate alternatives by taking into account individual preferences of stakeholders and aid in better decision-making. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  7. Milestone-Based Assessments Are Superior to Likert-Type Assessments in Illustrating Trainee Progression

    PubMed Central

    Bartlett, Kathleen W.; Whicker, Shari A.; Bookman, Jack; Narayan, Aditee P.; Staples, Betty B.; Hering, Holly; McGann, Kathleen A.

    2015-01-01

    Background The Pediatrics Milestone Project uses behavioral anchors, narrative descriptions of observable behaviors, to describe learner progression through the Accreditation Council for Graduate Medical Education competencies. Starting June 2014, pediatrics programs were required to submit milestone reports for their trainees semiannually. Likert-type scale assessment tools were not designed to inform milestone reporting, creating a challenge for Clinical Competency Committees. Objective To determine if milestone-based assessments better stratify trainees by training level compared to Likert-type assessments. Methods We compared assessment results for 3 subcompetencies after changing from a 5-point Likert scale to milestone-based behavioral anchors in July 2013. Program leadership evaluated the new system by (1) comparing PGY-1 mean scores on Likert-type versus milestone-based assessments; and (2) comparing mean scores on the Likert-type versus milestone-based assessments across PGY levels. Results Mean scores for PGY-1 residents were significantly higher on the prior year's Likert-type assessments than milestone-based assessments for all 3 subcompetencies (P < .01). Stratification by PGY level was not observed with Likert-type assessments (eg, interpersonal and communication skills 1 [ICS1] mean score for PGY-1, 3.99 versus PGY-3, 3.98; P  =  .98). In contrast, milestone-based assessments demonstrated stratification by PGY level (eg, the ICS1 mean score was 3.06 for PGY-1, 3.83 for PGY-2, and 3.99 for PGY-3; P < .01 for PGY-1 versus PGY-3). Significantly different means by trainee level were noted across 21 subcompetencies on milestone-based assessments (P < .01 for PGY-1 versus PGY-3). Conclusions Initial results indicate milestone-based assessments stratify trainee performance by level better than Likert-type assessments. Average PGY-level scores from milestone-based assessments may ultimately provide guidance for determining whether trainees are progressing at the expected pace. PMID:26217427

  8. Physician-Owned Surgical Hospitals Outperform Other Hospitals in Medicare Value-Based Purchasing Program.

    PubMed

    Ramirez, Adriana G; Tracci, Margaret C; Stukenborg, George J; Turrentine, Florence E; Kozower, Benjamin D; Jones, R Scott

    2016-10-01

    The Hospital Value-Based Purchasing Program measures value of care provided by participating Medicare hospitals and creates financial incentives for quality improvement and fosters increased transparency. Limited information is available comparing hospital performance across health care business models. The 2015 Hospital Value-Based Purchasing Program results were used to examine hospital performance by business model. General linear modeling assessed differences in mean total performance score, hospital case mix index, and differences after adjustment for differences in hospital case mix index. Of 3,089 hospitals with total performance scores, categories of representative health care business models included 104 physician-owned surgical hospitals, 111 University HealthSystem Consortium, 14 US News & World Report Honor Roll hospitals, 33 Kaiser Permanente, and 124 Pioneer accountable care organization affiliated hospitals. Estimated mean total performance scores for physician-owned surgical hospitals (64.4; 95% CI, 61.83-66.38) and Kaiser Permanente (60.79; 95% CI, 56.56-65.03) were significantly higher compared with all remaining hospitals, and University HealthSystem Consortium members (36.8; 95% CI, 34.51-39.17) performed below the mean (p < 0.0001). Significant differences in mean hospital case mix index included physician-owned surgical hospitals (mean 2.32; p < 0.0001), US News & World Report honorees (mean 2.24; p = 0.0140), and University HealthSystem Consortium members (mean 1.99; p < 0.0001), and Kaiser Permanente hospitals had lower case mix value (mean 1.54; p < 0.0001). Re-estimation of total performance scores did not change the original results after adjustment for differences in hospital case mix index. The Hospital Value-Based Purchasing Program revealed superior hospital performance associated with business model. Closer inspection of high-value hospitals can guide value improvement and policy-making decisions for all Medicare Value-Based Purchasing Program Hospitals. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Assessment of resident operative performance using a real-time mobile Web system: preparing for the milestone age.

    PubMed

    Wagner, Justin P; Chen, David C; Donahue, Timothy R; Quach, Chi; Hines, O Joe; Hiatt, Jonathan R; Tillou, Areti

    2014-01-01

    To satisfy trainees' operative competency requirements while improving feedback validity and timeliness using a mobile Web-based platform. The Southern Illinois University Operative Performance Rating Scale (OPRS) was embedded into a website formatted for mobile devices. From March 2013 to February 2014, faculty members were instructed to complete the OPRS form while providing verbal feedback to the operating resident at the conclusion of each procedure. Submitted data were compiled automatically within a secure Web-based spreadsheet. Conventional end-of-rotation performance (CERP) evaluations filed 2006 to 2013 and OPRS performance scores were compared by year of training using serial and independent-samples t tests. The mean CERP scores and OPRS overall resident operative performance scores were directly compared using a linear regression model. OPRS mobile site analytics were reviewed using a Web-based reporting program. Large university-based general surgery residency program. General Surgery faculty used the mobile Web OPRS system to rate resident performance. Residents and the program director reviewed evaluations semiannually. Over the study period, 18 faculty members and 37 residents logged 176 operations using the mobile OPRS system. There were 334 total OPRS website visits. Median time to complete an evaluation was 45 minutes from the end of the operation, and faculty spent an average of 134 seconds on the site to enter 1 assessment. In the 38,506 CERP evaluations reviewed, mean performance scores showed a positive linear trend of 2% change per year of training (p = 0.001). OPRS overall resident operative performance scores showed a significant linear (p = 0.001), quadratic (p = 0.001), and cubic (p = 0.003) trend of change per year of clinical training, reflecting the resident operative experience in our training program. Differences between postgraduate year-1 and postgraduate year-5 overall performance scores were greater with the OPRS (mean = 0.96, CI: 0.55-1.38) than with CERP measures (mean = 0.37, CI: 0.34-0.41). Additionally, there were consistent increases in each of the OPRS subcategories. In contrast to CERPs, the OPRS fully satisfies the Accreditation Council for Graduate Medical Education and American Board of Surgery operative assessment requirements. The mobile Web platform provides a convenient interface, broad accessibility, automatic data compilation, and compatibility with common database and statistical software. Our mobile OPRS system encourages candid feedback dialog and generates a comprehensive review of individual and group-wide operative proficiency in real time. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. The Automated Assessment of Postural Stability: Balance Detection Algorithm.

    PubMed

    Napoli, Alessandro; Glass, Stephen M; Tucker, Carole; Obeid, Iyad

    2017-12-01

    Impaired balance is a common indicator of mild traumatic brain injury, concussion and musculoskeletal injury. Given the clinical relevance of such injuries, especially in military settings, it is paramount to develop more accurate and reliable on-field evaluation tools. This work presents the design and implementation of the automated assessment of postural stability (AAPS) system, for on-field evaluations following concussion. The AAPS is a computer system, based on inexpensive off-the-shelf components and custom software, that aims to automatically and reliably evaluate balance deficits, by replicating a known on-field clinical test, namely, the Balance Error Scoring System (BESS). The AAPS main innovation is its balance error detection algorithm that has been designed to acquire data from a Microsoft Kinect ® sensor and convert them into clinically-relevant BESS scores, using the same detection criteria defined by the original BESS test. In order to assess the AAPS balance evaluation capability, a total of 15 healthy subjects (7 male, 8 female) were required to perform the BESS test, while simultaneously being tracked by a Kinect 2.0 sensor and a professional-grade motion capture system (Qualisys AB, Gothenburg, Sweden). High definition videos with BESS trials were scored off-line by three experienced observers for reference scores. AAPS performance was assessed by comparing the AAPS automated scores to those derived by three experienced observers. Our results show that the AAPS error detection algorithm presented here can accurately and precisely detect balance deficits with performance levels that are comparable to those of experienced medical personnel. Specifically, agreement levels between the AAPS algorithm and the human average BESS scores ranging between 87.9% (single-leg on foam) and 99.8% (double-leg on firm ground) were detected. Moreover, statistically significant differences in balance scores were not detected by an ANOVA test with alpha equal to 0.05. Despite some level of disagreement between human and AAPS-generated scores, the use of an automated system yields important advantages over currently available human-based alternatives. These results underscore the value of using the AAPS, that can be quickly deployed in the field and/or in outdoor settings with minimal set-up time. Finally, the AAPS can record multiple error types and their time course with extremely high temporal resolution. These features are not achievable by humans, who cannot keep track of multiple balance errors with such a high resolution. Together, these results suggest that computerized BESS calculation may provide more accurate and consistent measures of balance than those derived from human experts.

  11. Self-reported well-being score modelling and prediction: Proof-of-concept of an approach based on linear dynamic systems.

    PubMed

    Xinyang Li; Poli, Riccardo; Valenza, Gaetano; Scilingo, Enzo Pasquale; Citi, Luca

    2017-07-01

    Assessment and recognition of perceived well-being has wide applications in the development of assistive healthcare systems for people with physical and mental disorders. In practical data collection, these systems need to be less intrusive, and respect users' autonomy and willingness as much as possible. As a result, self-reported data are not necessarily available at all times. Conventional classifiers, which usually require feature vectors of a prefixed dimension, are not well suited for this problem. To address the issue of non-uniformly sampled measurements, in this study we propose a method for the modelling and prediction of self-reported well-being scores based on a linear dynamic system. Within the model, we formulate different features as observations, making predictions even in the presence of inconsistent and irregular data. We evaluate the proposed method with synthetic data, as well as real data from two patients diagnosed with cancer. In the latter, self-reported scores from three well-being-related scales were collected over a period of approximately 60 days. Prompted each day, the patients had the choice whether to respond or not. Results show that the proposed model is able to track and predict the patients' perceived well-being dynamics despite the irregularly sampled data.

  12. The New York State risk score for predicting in-hospital/30-day mortality following percutaneous coronary intervention.

    PubMed

    Hannan, Edward L; Farrell, Louise Szypulski; Walford, Gary; Jacobs, Alice K; Berger, Peter B; Holmes, David R; Stamato, Nicholas J; Sharma, Samin; King, Spencer B

    2013-06-01

    This study sought to develop a percutaneous coronary intervention (PCI) risk score for in-hospital/30-day mortality. Risk scores are simplified linear scores that provide clinicians with quick estimates of patients' short-term mortality rates for informed consent and to determine the appropriate intervention. Earlier PCI risk scores were based on in-hospital mortality. However, for PCI, a substantial percentage of patients die within 30 days of the procedure after discharge. New York's Percutaneous Coronary Interventions Reporting System was used to develop an in-hospital/30-day logistic regression model for patients undergoing PCI in 2010, and this model was converted into a simple linear risk score that estimates mortality rates. The score was validated by applying it to 2009 New York PCI data. Subsequent analyses evaluated the ability of the score to predict complications and length of stay. A total of 54,223 patients were used to develop the risk score. There are 11 risk factors that make up the score, with risk factor scores ranging from 1 to 9, and the highest total score is 34. The score was validated based on patients undergoing PCI in the previous year, and accurately predicted mortality for all patients as well as patients who recently suffered a myocardial infarction (MI). The PCI risk score developed here enables clinicians to estimate in-hospital/30-day mortality very quickly and quite accurately. It accurately predicts mortality for patients undergoing PCI in the previous year and for MI patients, and is also moderately related to perioperative complications and length of stay. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Design, implementation, and psychometric analysis of a scoring instrument for simulated pediatric resuscitation: a report from the EXPRESS pediatric investigators.

    PubMed

    Donoghue, Aaron; Ventre, Kathleen; Boulet, John; Brett-Fleegler, Marisa; Nishisaki, Akira; Overly, Frank; Cheng, Adam

    2011-04-01

    Robustly tested instruments for quantifying clinical performance during pediatric resuscitation are lacking. Examining Pediatric Resuscitation Education through Simulation and Scripting Collaborative was established to conduct multicenter trials of simulation education in pediatric resuscitation, evaluating performance with multiple instruments, one of which is the Clinical Performance Tool (CPT). We hypothesize that the CPT will measure clinical performance during simulated pediatric resuscitation in a reliable and valid manner. Using a pediatric resuscitation scenario as a basis, a scoring system was designed based on Pediatric Advanced Life Support algorithms comprising 21 tasks. Each task was scored as follows: task not performed (0 points); task performed partially, incorrectly, or late (1 point); and task performed completely, correctly, and within the recommended time frame (2 points). Study teams at 14 children's hospitals went through the scenario twice (PRE and POST) with an interposed 20-minute debriefing. Both scenarios for each of eight study teams were scored by multiple raters. A generalizability study, based on the PRE scores, was conducted to investigate the sources of measurement error in the CPT total scores. Inter-rater reliability was estimated based on the variance components. Validity was assessed by repeated measures analysis of variance comparing PRE and POST scores. Sixteen resuscitation scenarios were reviewed and scored by seven raters. Inter-rater reliability for the overall CPT score was 0.63. POST scores were found to be significantly improved compared with PRE scores when controlled for within-subject covariance (F1,15 = 4.64, P < 0.05). The variance component ascribable to rater was 2.4%. Reliable and valid measures of performance in simulated pediatric resuscitation can be obtained from the CPT. Future studies should examine the applicability of trichotomous scoring instruments to other clinical scenarios, as well as performance during actual resuscitations.

  14. Validation study of an electronic method of condensed outcomes tools reporting in orthopaedics.

    PubMed

    Farr, Jack; Verma, Nikhil; Cole, Brian J

    2013-12-01

    Patient-reported outcomes (PRO) instruments are a vital source of data for evaluating the efficacy of medical treatments. Historically, outcomes instruments have been designed, validated, and implemented as paper-based questionnaires. The collection of paper-based outcomes information may result in patients becoming fatigued as they respond to redundant questions. This problem is exacerbated when multiple PRO measures are provided to a single patient. In addition, the management and analysis of data collected in paper format involves labor-intensive processes to score and render the data analyzable. Computer-based outcomes systems have the potential to mitigate these problems by reformatting multiple outcomes tools into a single, user-friendly tool.The study aimed to determine whether the electronic outcomes system presented produces results comparable with the test-retest correlations reported for the corresponding orthopedic paper-based outcomes instruments.The study is designed as a crossover study based on consecutive orthopaedic patients arriving at one of two designated orthopedic knee clinics.Patients were assigned to complete either a paper or a computer-administered questionnaire based on a similar set of questions (Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee form, 36-Item Short Form survey, version 1, Lysholm Knee Scoring Scale). Each patient completed the same surveys using the other instrument, so that all patients had completed both paper and electronic versions. Correlations between the results from the two modes were studied and compared with test-retest data from the original validation studies.The original validation studies established test-retest reliability by computing correlation coefficients for two administrations of the paper instrument. Those correlation coefficients were all in the range of 0.7 to 0.9, which was deemed satisfactory. The present study computed correlation coefficients between the paper and electronic modes of administration. These correlation coefficients demonstrated similar results with an overall value of 0.86.On the basis of the correlation coefficients, the electronic application of commonly used knee outcome scores compare variably to the traditional paper variants with a high rate of test-retest correlation. This equivalence supports the use of the condensed electronic outcomes system and validates comparison of scores between electronic and paper modes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Capturing, Codifying and Scoring Complex Data for Innovative, Computer-Based Items.

    ERIC Educational Resources Information Center

    Luecht, Richard M.

    The Microsoft Certification Program (MCP) includes many new computer-based item types, based on complex cases involving the Windows 2000 (registered) operating system. This Innovative Item Technology (IIT) has presented challenges beyond traditional psychometric considerations such as capturing and storing the relevant response data from…

  16. Anomaly Detection and Life Pattern Estimation for the Elderly Based on Categorization of Accumulated Data

    NASA Astrophysics Data System (ADS)

    Mori, Taketoshi; Ishino, Takahito; Noguchi, Hiroshi; Shimosaka, Masamichi; Sato, Tomomasa

    2011-06-01

    We propose a life pattern estimation method and an anomaly detection method for elderly people living alone. In our observation system for such people, we deploy some pyroelectric sensors into the house and measure the person's activities all the time in order to grasp the person's life pattern. The data are transferred successively to the operation center and displayed to the nurses in the center in a precise way. Then, the nurses decide whether the data is the anomaly or not. In the system, the people whose features in their life resemble each other are categorized as the same group. Anomalies occurred in the past are shared in the group and utilized in the anomaly detection algorithm. This algorithm is based on "anomaly score." The "anomaly score" is figured out by utilizing the activeness of the person. This activeness is approximately proportional to the frequency of the sensor response in a minute. The "anomaly score" is calculated from the difference between the activeness in the present and the past one averaged in the long term. Thus, the score is positive if the activeness in the present is higher than the average in the past, and the score is negative if the value in the present is lower than the average. If the score exceeds a certain threshold, it means that an anomaly event occurs. Moreover, we developed an activity estimation algorithm. This algorithm estimates the residents' basic activities such as uprising, outing, and so on. The estimation is shown to the nurses with the "anomaly score" of the residents. The nurses can understand the residents' health conditions by combining these two information.

  17. Instrumented sparring vest to aid in martial arts scoring.

    PubMed

    Harrigan, Katie; Logan, Rachel; Sluti, Anne; Rogge, Renee

    2006-01-01

    Competitors in certain martial arts, such as Taekwondo, are required to wear protective vests during competition. This article outlines the design and fabrication of an instrumented martial arts sparring vest that will aid in martial arts scoring, which is currently a work in progress. After fabrication, this instrumented vest and associated system will not only provide the same protection as before modification, but will also report the location and force magnitude of strikes applied to the vest. This will aid in scoring of martial arts competitions, as it will determine if a strike is forceful enough to be considered deliberate and therefore is a valid point-scoring strike. This will make scoring of competitions unbiased and equal for all competitors, something that is difficult to achieve based solely on a judge's assessment by observation. The system will also indicate the probable injury resulting from a strike, for example, no injury, bruising or bone fracture. If a competitor's strike force is excessive and serious injury could result, the system will indicate this so action can be taken, such as penalty or disqualification of a competitor. Both tissue testing and force testing will be conducted prior to vest fabrication to determine estimates of forces that will damage tissue and typical forces experienced during competition. After testing is complete, the system will be fabricated and the testing results will be implemented into the associated software.

  18. The 2014 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma: Definition of Grading Patterns and Proposal for a New Grading System.

    PubMed

    Epstein, Jonathan I; Egevad, Lars; Amin, Mahul B; Delahunt, Brett; Srigley, John R; Humphrey, Peter A

    2016-02-01

    In November, 2014, 65 prostate cancer pathology experts, along with 17 clinicians including urologists, radiation oncologists, and medical oncologists from 19 different countries gathered in a consensus conference to update the grading of prostate cancer, last revised in 2005. The major conclusions were: (1) Cribriform glands should be assigned a Gleason pattern 4, regardless of morphology; (2) Glomeruloid glands should be assigned a Gleason pattern 4, regardless of morphology; (3) Grading of mucinous carcinoma of the prostate should be based on its underlying growth pattern rather than grading them all as pattern 4; and (4) Intraductal carcinoma of the prostate without invasive carcinoma should not be assigned a Gleason grade and a comment as to its invariable association with aggressive prostate cancer should be made. Regarding morphologies of Gleason patterns, there was clear consensus on: (1) Gleason pattern 4 includes cribriform, fused, and poorly formed glands; (2) The term hypernephromatoid cancer should not be used; (3) For a diagnosis of Gleason pattern 4, it needs to be seen at 10x lens magnification; (4) Occasional/seemingly poorly formed or fused glands between well-formed glands is insufficient for a diagnosis of pattern 4; (5) In cases with borderline morphology between Gleason pattern 3 and pattern 4 and crush artifacts, the lower grade should be favored; (6) Branched glands are allowed in Gleason pattern 3; (7) Small solid cylinders represent Gleason pattern 5; (8) Solid medium to large nests with rosette-like spaces should be considered to represent Gleason pattern 5; and (9) Presence of unequivocal comedonecrosis, even if focal is indicative of Gleason pattern 5. It was recognized by both pathologists and clinicians that despite the above changes, there were deficiencies with the Gleason system. The Gleason grading system ranges from 2 to 10, yet 6 is the lowest score currently assigned. When patients are told that they have a Gleason score 6 out of 10, it implies that their prognosis is intermediate and contributes to their fear of having a more aggressive cancer. Also, in the literature and for therapeutic purposes, various scores have been incorrectly grouped together with the assumption that they have a similar prognosis. For example, many classification systems consider Gleason score 7 as a single score without distinguishing 3+4 versus 4+3, despite studies showing significantly worse prognosis for the latter. The basis for a new grading system was proposed in 2013 by one of the authors (J.I.E.) based on data from Johns Hopkins Hospital resulting in 5 prognostically distinct Grade Groups. This new system was validated in a multi-institutional study of over 20,000 radical prostatectomy specimens, over 16,000 needle biopsy specimens, and over 5,000 biopsies followed by radiation therapy. There was broad (90%) consensus for the adoption of this new prostate cancer Grading system in the 2014 consensus conference based on: (1) the new classification provided more accurate stratification of tumors than the current system; (2) the classification simplified the number of grading categories from Gleason scores 2 to 10, with even more permutations based on different pattern combinations, to Grade Groups 1 to 5; (3) the lowest grade is 1 not 6 as in Gleason, with the potential to reduce overtreatment of indolent cancer; and (4) the current modified Gleason grading, which forms the basis for the new grade groups, bears little resemblance to the original Gleason system. The new grades would, for the foreseeable future, be used in conjunction with the Gleason system [ie. Gleason score 3+3=6 (Grade Group 1)]. The new grading system and the terminology Grade Groups 1-5 have also been accepted by the World Health Organization for the 2016 edition of Pathology and Genetics: Tumours of the Urinary System and Male Genital Organs.

  19. Separating the Signal from the Noise: An Examination of Student and Teacher Scores Based on Student Learning Objectives (SLOs) in One State

    ERIC Educational Resources Information Center

    Buckley, Katie Hills

    2015-01-01

    Despite the prevalence of student learning objectives (SLOs) in teacher evaluation systems throughout the United States, research on the validity of student and teacher SLO scores used for high-stakes decisions is lacking. For this reason, this dissertation is comprised of two chapters that examine student and teacher-level SLO performance data…

  20. Checklists for powder inhaler technique: a review and recommendations.

    PubMed

    Basheti, Iman A; Bosnic-Anticevich, Sinthia Z; Armour, Carol L; Reddel, Helen K

    2014-07-01

    Turbuhaler and Diskus are commonly used powder inhaler devices for patients with respiratory disease. Their effectiveness is limited in part by a patient's ability to use them correctly. This has led to numerous studies being conducted over the last decade to assess the correct use of these devices by patients and health care professionals. These studies have generally used device-specific checklists to assess technique, this being the most feasible and accessible method for assessment. However, divergence between the checklists and scoring systems for the same device in different studies makes direct comparison of results difficult and at times inappropriate. Little evidence is available to assess the relative importance of different criteria; however, brief patient training based on specific inhaler technique checklists leads to significant improvement in asthma outcomes. This paper reviews common checklists and scoring systems used for Turbuhaler and Diskus, discusses the problem of heterogeneity between different checklists, and finally recommends suitable checklists and scoring systems for these devices based on the literature and previous findings. Only when similar checklists are used across different research studies will accurate comparisons and meta-analysis be possible. Copyright © 2014 by Daedalus Enterprises.

  1. Do Examinees Understand Score Reports for Alternate Methods of Scoring Computer Based Tests?

    ERIC Educational Resources Information Center

    Whittaker, Tiffany A.; Williams, Natasha J.; Dodd, Barbara G.

    2011-01-01

    This study assessed the interpretability of scaled scores based on either number correct (NC) scoring for a paper-and-pencil test or one of two methods of scoring computer-based tests: an item pattern (IP) scoring method and a method based on equated NC scoring. The equated NC scoring method for computer-based tests was proposed as an alternative…

  2. Open-Source Logic-Based Automated Sleep Scoring Software using Electrophysiological Recordings in Rats

    PubMed Central

    Gross, Brooks A.; Walsh, Christine M.; Turakhia, Apurva A.; Booth, Victoria; Mashour, George; Poe, Gina R.

    2009-01-01

    Manual state scoring of physiological recordings in sleep studies is time-consuming, resulting in a data backlog, research delays and increased personnel costs. We developed MATLAB-based software to automate scoring of sleep/waking states in rats, potentially extendable to other animals, from a variety of recording systems. The software contains two programs, Sleep Scorer and Auto-Scorer, for manual and automated scoring. Auto-Scorer is a logic-based program that displays power spectral densities of an electromyographic signal and σ, δ, and θ frequency bands of an electroencephalographic signal, along with the δ/θ ratio and σ ×θ, for every epoch. The user defines thresholds from the training file state definitions which the Auto-Scorer uses with logic to discriminate the state of every epoch in the file. Auto-Scorer was evaluated by comparing its output to manually scored files from 6 rats under 2 experimental conditions by 3 users. Each user generated a training file, set thresholds, and autoscored the 12 files into 4 states (waking, non-REM, transition-to-REM, and REM sleep) in ¼ the time required to manually score the file. Overall performance comparisons between Auto-Scorer and manual scoring resulted in a mean agreement of 80.24 +/− 7.87%, comparable to the average agreement among 3 manual scorers (83.03 +/− 4.00%). There was no significant difference between user-user and user-Auto-Scorer agreement ratios. These results support the use of our open-source Auto-Scorer, coupled with user review, to rapidly and accurately score sleep/waking states from rat recordings. PMID:19615408

  3. Management of benign papilloma without atypia diagnosed at ultrasound-guided core needle biopsy: Scoring system for predicting malignancy.

    PubMed

    Ahn, Soo Kyung; Han, Wonshik; Moon, Hyeong-Gon; Kim, Min Kyoon; Noh, Dong-Young; Jung, Bong-Wha; Kim, Sung-Won; Ko, Eunyoung

    2018-01-01

    The management of benign intraductal papilloma diagnosed on core needle biopsy (CNB) remains unclear. This study was designed to evaluate factors predicting malignancy in patients diagnosed with benign papilloma without atypia at ultrasound-guided CNB and to develop a scoring system predicting malignancy based on clinical, radiological and pathological factors on further excisional biopsy. The study enrolled patients diagnosed with benign papillomas (including benign and atypical papillary lesions) at CNB. Multivariate analysis was used to identify relevant clinical, radiological and pathological factors that may predict malignancy. A total of 520 CNBs were diagnosed with benign or atypical papilloma. Of these, 452 were benign papilloma without atypia. Of the 250 lesions subsequently excised surgically from 234 women, 17 (6.8%) were diagnosed with malignancy. Multivariate analysis revealed that bloody nipple discharge, size on imaging ≥15 mm, BI-RADS≥4b, peripheral location and palpability were independent predictors of malignancy. A scoring system was developed based on logistic regression models and beta coefficients for each variable. The area under the ROC curve was 0.947 (95% CI: 0.913-0.981, p < 0.001) and a negative predictive value was 100%. In a validation set of 62 patients, an area under the ROC curve was 0.926 (95% CI: 0.857-0.995, p < 0.001). A scoring system predicting malignancy in patients diagnosed by CNB with benign papilloma without atypia was developed. This system was able to identify a subset of patients with lesions likely to be benign, indicating that imaging follow-up rather than surgical excision may be appropriate. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  4. Introduction to an Open Source Internet-Based Testing Program for Medical Student Examinations

    PubMed Central

    2009-01-01

    The author developed a freely available open source internet-based testing program for medical examination. PHP and Java script were used as the programming language and postgreSQL as the database management system on an Apache web server and Linux operating system. The system approach was that a super user inputs the items, each school administrator inputs the examinees' information, and examinees access the system. The examinee's score is displayed immediately after examination with item analysis. The set-up of the system beginning with installation is described. This may help medical professors to easily adopt an internet-based testing system for medical education. PMID:20046457

  5. Introduction to an open source internet-based testing program for medical student examinations.

    PubMed

    Lee, Yoon-Hwan

    2009-12-20

    The author developed a freely available open source internet-based testing program for medical examination. PHP and Java script were used as the programming language and postgreSQL as the database management system on an Apache web server and Linux operating system. The system approach was that a super user inputs the items, each school administrator inputs the examinees' information, and examinees access the system. The examinee's score is displayed immediately after examination with item analysis. The set-up of the system beginning with installation is described. This may help medical professors to easily adopt an internet-based testing system for medical education.

  6. Instance-Based Question Answering

    DTIC Science & Technology

    2006-12-01

    answer clustering, composition, and scoring. Moreover, with the effort dedicated to improving monolingual system performance, system parameters are...text collections: document type, manual or automatic annotations (if any), and stylistic and notational differences in technical terms. Monolingual ...forum in which cross language retrieval systems and question answering systems are tested for various Eu- ropean languages. The CLEF QA monolingual task

  7. Evaluating the usability of speech recognition to create clinical documentation using a commercial electronic health record.

    PubMed

    Hodgson, Tobias; Magrabi, Farah; Coiera, Enrico

    2018-05-01

    To conduct a usability study exploring the value of using speech recognition (SR) for clinical documentation tasks within an electronic health record (EHR) system. Thirty-five emergency department clinicians completed a system usability scale (SUS) questionnaire. The study was undertaken after participants undertook randomly allocated clinical documentation tasks using keyboard and mouse (KBM) or SR. SUS scores were analyzed and the results with KBM were compared to SR results. Significant difference in SUS scores between EHR system use with and without SR were observed (KBM 67, SR 61; P = 0.045; CI, 0.1 to 12.0). Nineteen of 35 participants scored higher for EHR with KBM, 11 higher for EHR with SR and 5 gave the same score for both. Factor analysis showed no significant difference in scores for the sub-element of usability (EHR with KBM 65, EHR with SR 62; P = 0.255; CI, -2.6 to 9.5). Scores for the sub-element of learnability were significantly different (KBM 72, SR 55; P < 0.001; CI, 9.8 to 23.5). A significant correlation was found between the perceived usability of the two system configurations (EHR with KBM or SR) and the efficiency of documentation (time to document) (P = 0.002; CI, 10.5 to -0.1) but not with safety (number of errors) (P = 0.90; CI, -2.3 to 2.6). SR was associated with significantly reduced overall usability scores, even though it is often positioned as ease of use technology. SR was perceived to impose larger costs in terms of learnability via training and support requirements for EHR based documentation when compared to using KBM. Lower usability scores were significantly associated with longer documentation times. The usability of EHR systems with any input modality is an area that requires continued development. The addition of an SR component to an EHR system may cause a significant reduction in terms of perceived usability by clinicians. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Merit-Based Incentive Payment System: Meaningful Changes in the Final Rule Brings Cautious Optimism.

    PubMed

    Manchikanti, Laxmaiah; Helm Ii, Standiford; Calodney, Aaron K; Hirsch, Joshua A

    2017-01-01

    The Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) eliminated the flawed Sustainable Growth Rate (SGR) act formula - a longstanding crucial issue of concern for health care providers and Medicare beneficiaries. MACRA also included a quality improvement program entitled, "The Merit-Based Incentive Payment System, or MIPS." The proposed rule of MIPS sought to streamline existing federal quality efforts and therefore linked 4 distinct programs into one. Three existing programs, meaningful use (MU), Physician Quality Reporting System (PQRS), value-based payment (VBP) system were merged with the addition of Clinical Improvement Activity category. The proposed rule also changed the name of MU to Advancing Care Information, or ACI. ACI contributes to 25% of composite score of the four programs, PQRS contributes 50% of the composite score, while VBP system, which deals with resource use or cost, contributes to 10% of the composite score. The newest category, Improvement Activities or IA, contributes 15% to the composite score. The proposed rule also created what it called a design incentive that drives movement to delivery system reform principles with the inclusion of Advanced Alternative Payment Models (APMs).Following the release of the proposed rule, the medical community, as well as Congress, provided substantial input to Centers for Medicare and Medicaid Services (CMS),expressing their concern. American Society of Interventional Pain Physicians (ASIPP) focused on 3 important aspects: delay the implementation, provide a 3-month performance period, and provide ability to submit meaningful quality measures in a timely and economic manner. The final rule accepted many of the comments from various organizations, including several of those specifically emphasized by ASIPP, with acceptance of 3-month reporting period, as well as the ability to submit non-MIPS measures to improve real quality and make the system meaningful. CMS also provided a mechanism for physicians to avoid penalties for non-reporting with reporting of just a single patient. In summary, CMS has provided substantial flexibility with mechanisms to avoid penalties, reporting for 90 continuous days, increasing the low volume threshold, changing the reporting burden and data thresholds and, finally, coordination between performance categories. The final rule has made MIPS more meaningful with bonuses for exceptional performance, the ability to report for 90 days, and to report on 50% of the patients in 2017 and 60% of the patients in 2018. The final rule also reduced the quality measures to 6, including only one outcome or high priority measure with elimination of cross cutting measure requirement. In addition, the final rule reduced the burden of ACI, improved the coordination of performance, reduced improvement activities burden from 60 points to 40 points, and finally improved coordination between performance categories. Multiple concerns remain regarding the reduction in scoring for quality improvement in future years, increase in proportion of MIPS scoring for resource use utilizing flawed, claims based methodology and the continuation of the disproportionate importance of ACI, an expensive program that can be onerous for providers which in many ways has not lived up to its promise. Key words: Medicare Access and CHIP Reauthorization Act of 2015, merit-based incentive payment system, quality performance measures, resource use, improvement activities, advancing care information performance category.

  9. [Scoring systems in intensive care medicine : principles, models, application and limits].

    PubMed

    Fleig, V; Brenck, F; Wolff, M; Weigand, M A

    2011-10-01

    Scoring systems are used in all diagnostic areas of medicine. Several parameters are evaluated and rated with points according to their value in order to simplify a complex clinical situation with a score. The application ranges from the classification of disease severity through determining the number of staff for the intensive care unit (ICU) to the evaluation of new therapies under study conditions. Since the introduction of scoring systems in the 1980's a variety of different score models has been developed. The scoring systems that are employed in intensive care and are discussed in this article can be categorized into prognostic scores, expenses scores and disease-specific scores. Since the introduction of compulsory recording of two scoring systems for accounting in the German diagnosis-related groups (DRG) system, these tools have gained more importance for all intensive care physicians. Problems remain in the valid calculation of scores and interpretation of the results.

  10. Algorithmic approach to patients presenting with heartburn and epigastric pain refractory to empiric proton pump inhibitor therapy.

    PubMed

    Roorda, Andrew K; Marcus, Samuel N; Triadafilopoulos, George

    2011-10-01

    Reflux-like dyspepsia (RLD), where predominant epigastric pain is associated with heartburn and/or regurgitation, is a common clinical syndrome in both primary and specialty care. Because symptom frequency and severity vary, overlap among gastroesophageal reflux disease (GERD), non-erosive reflux disease (NERD), and RLD, is quite common. The chronic and recurrent nature of RLD and its variable response to proton pump inhibitor (PPI) therapy remain problematic. To examine the prevalence of GERD, NERD, and RLD in a community setting using an algorithmic approach and to assess the potential, reproducibility, and validity of a multi-factorial scoring system in discriminating patients with RLD from those with GERD or NERD. Using a novel algorithmic approach, we evaluated an outpatient, community-based cohort referred to a gastroenterologist because of epigastric pain and heartburn that were only partially relieved by PPI. After an initial symptom evaluation (for epigastric pain, heartburn, regurgitation, dysphagia), an endoscopy and distal esophageal biopsies were performed, followed by esophageal motility and 24-h ambulatory pH monitoring to assess esophageal function and pathological acid exposure. A scoring system based on presence of symptoms and severity of findings was devised. Data was collected in two stages: subjects in the first stage were designated as the derivation cohort; subjects in the second stage were labeled the validation cohort. The total cohort comprised 159 patients (59 males, 100 females; mean age 52). On endoscopy, 30 patients (19%) had complicated esophagitis (CE) and 11 (7%) had Barrett's esophagus (BE) and were classified collectively as patients with GERD. One-hundred and eighteen (74%) patients had normal esophagus. Of these, 94 (59%) had one or more of the following: hiatal hernia, positive biopsy, abnormal pH, and/or abnormal motility studies and were classified as patients with NERD. The remaining 24 patients (15%) had normal functional studies and were classified as patients with RLD. Utilizing the scoring system a total score was calculated for each patient and effectively distinguished patients with GERD (mean score 9), NERD (mean score 6), and RLD (mean score 3). Receiver operating characteristic (ROC) curves confirmed the optimization of the model, particularly in RLD (P = 0.0001, 95% CI: 0.91-0.98). In a community cohort of patients presenting with heartburn and epigastric pain partly refractory to empiric PPI therapy, the prevalence of CE was 19%, BE 7%, NERD 59%, and RLD 15%. An algorithmic approach coupled with a novel scoring system, effectively distinguishes GERD from NERD and RLD and facilitates further management decisions. This novel and simple scoring system is both reproducible and validated as a diagnostic aid in evaluating patients presenting with both epigastric pain and heartburn.

  11. Tumour border configuration in colorectal cancer: proposal for an alternative scoring system based on the percentage of infiltrating margin.

    PubMed

    Karamitopoulou, Eva; Zlobec, Inti; Koelzer, Viktor Hendrik; Langer, Rupert; Dawson, Heather; Lugli, Alessandro

    2015-10-01

    Information on tumour border configuration (TBC) in colorectal cancer (CRC) is currently not included in most pathology reports, owing to lack of reproducibility and/or established evaluation systems. The aim of this study was to investigate whether an alternative scoring system based on the percentage of the infiltrating component may represent a reliable method for assessing TBC. Two hundred and fifteen CRCs with complete clinicopathological data were evaluated by two independent observers, both 'traditionally' by assigning the tumours into pushing/infiltrating/mixed categories, and alternatively by scoring the percentage of infiltrating margin. With the pushing/infiltrating/mixed pattern method, interobserver agreement (IOA) was moderate (κ = 0.58), whereas with the percentage of infiltrating margins method, IOA was excellent (intraclass correlation coefficient of 0.86). A higher percentage of infiltrating margin correlated with adverse features such as higher grade (P = 0.0025), higher pT (P = 0.0007), pN (P = 0.0001) and pM classification (P = 0.0063), high-grade tumour budding (P < 0.0001), lymphatic invasion (P < 0.0001), vascular invasion (P = 0.0032), and shorter survival (P = 0.0008), and was significantly associated with an increased probability of lymph node metastasis (P < 0.001). Information on TBC gives additional prognostic value to pathology reports on CRC. The novel proposed scoring system, by using the percentage of infiltrating margin, outperforms the 'traditional' way of reporting TBC. Additionally, it is reproducible and simple to apply, and can therefore be easily integrated into daily diagnostic practice. © 2015 John Wiley & Sons Ltd.

  12. Impaired or Not Impaired, That Is the Question: Navigating the Challenges Associated with Using Canadian Normative Data in a Comprehensive Test Battery That Contains American Tests

    PubMed Central

    Chevalier, Thérèse M.; Stewart, Garth; Nelson, Monty; McInerney, Robert J.; Brodie, Norman

    2016-01-01

    It has been well documented that IQ scores calculated using Canadian norms are generally 2–5 points lower than those calculated using American norms on the Wechsler IQ scales. However, recent findings have demonstrated that the difference may be significantly larger for individuals with certain demographic characteristics, and this has prompted discussion about the appropriateness of using the Canadian normative system with a clinical population in Canada. This study compared the interpretive effects of applying the American and Canadian normative systems in a clinical sample. We used a multivariate analysis of variance (ANOVA) to calculate differences between IQ and Index scores in a clinical sample, and mixed model ANOVAs to assess the pattern of differences across age and ability level. As expected, Full Scale IQ scores calculated using Canadian norms were systematically lower than those calculated using American norms, but differences were significantly larger for individuals classified as having extremely low or borderline intellectual functioning when compared with those who scored in the average range. Implications of clinically different conclusions for up to 52.8% of patients based on these discrepancies highlight a unique dilemma facing Canadian clinicians, and underscore the need for caution when choosing a normative system with which to interpret WAIS-IV results in the context of a neuropsychological test battery in Canada. Based on these findings, we offer guidelines for best practice for Canadian clinicians when interpreting data from neuropsychological test batteries that include different normative systems, and suggestions to assist with future test development. PMID:27246955

  13. Effects of Boron-Based Gel on Radiation-Induced Dermatitis in Breast Cancer: A Double-Blind, Placebo-Controlled Trial.

    PubMed

    Aysan, Erhan; Idiz, Ufuk Oguz; Elmas, Leyla; Saglam, Esra Kaytan; Akgun, Zuleyha; Yucel, Serap Baskaya

    2017-06-01

    This study is aimed to evaluate the effects of boron on radiation-induced skin reactions (RISR) in breast cancer patients. After 47 patients with invasive ductal carcinoma underwent radiotherapy, 23 (49%) received a boron-based gel, and 24 (51%) received placebo. Assessments were performed according to the Radiation Therapy Oncology Group (RTOG) skin scale and a Five-Point Horizontal Scale (FPHS). At the end of the fifth week of radiotherapy, the RTOG scores in the boron group were significantly lower than those in the placebo group (p = .024). The FPHS score was higher in the placebo group than in the boron group, and this difference was not statistically significant (p = .079). Using the RTOG scoring system, we revealed that the application of a boron-based gel diminished RISR. The mechanism of action is unclear but may be related to antioxidant, wound healing, and thermal degradation effects of boron.

  14. Automatic Summarization of MEDLINE Citations for Evidence–Based Medical Treatment: A Topic-Oriented Evaluation

    PubMed Central

    Fiszman, Marcelo; Demner-Fushman, Dina; Kilicoglu, Halil; Rindflesch, Thomas C.

    2009-01-01

    As the number of electronic biomedical textual resources increases, it becomes harder for physicians to find useful answers at the point of care. Information retrieval applications provide access to databases; however, little research has been done on using automatic summarization to help navigate the documents returned by these systems. After presenting a semantic abstraction automatic summarization system for MEDLINE citations, we concentrate on evaluating its ability to identify useful drug interventions for fifty-three diseases. The evaluation methodology uses existing sources of evidence-based medicine as surrogates for a physician-annotated reference standard. Mean average precision (MAP) and a clinical usefulness score developed for this study were computed as performance metrics. The automatic summarization system significantly outperformed the baseline in both metrics. The MAP gain was 0.17 (p < 0.01) and the increase in the overall score of clinical usefulness was 0.39 (p < 0.05). PMID:19022398

  15. [Utility of axial images in an early Alzheimer disease diagnosis support system (VSRAD)].

    PubMed

    Goto, Masami; Aoki, Shigeki; Abe, Osamu; Masumoto, Tomohiko; Watanabe, Yasushi; Satake, Yoshiroh; Nishida, Katsuji; Ino, Kenji; Yano, Keiichi; Iida, Kyohhito; Mima, Kazuo; Ohtomo, Kuni

    2006-09-20

    In recent years, voxel-based morphometry (VBM) has become a popular tool for the early diagnosis of Alzheimer disease. The Voxel-Based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), a VBM system that uses MRI, has been reported to be clinically useful. The able-bodied person database (DB) of VSRAD, which employs sagittal plane imaging, is not suitable for analysis by axial plane imaging. However, axial plane imaging is useful for avoiding motion artifacts from the eyeball. Therefore, we created an able-bodied person DB by axial plane imaging and examined its utility. We also analyzed groups of able-bodied persons and persons with dementia by axial plane imaging and reviewed the validity. After using the DB of axial plane imaging, the Z-score of the intrahippocampal region improved by 8 in 13 instances. In all brains, the Z-score improved by 13 in all instances.

  16. New methods for analyzing semantic graph based assessments in science education

    NASA Astrophysics Data System (ADS)

    Vikaros, Lance Steven

    This research investigated how the scoring of semantic graphs (known by many as concept maps) could be improved and automated in order to address issues of inter-rater reliability and scalability. As part of the NSF funded SENSE-IT project to introduce secondary school science students to sensor networks (NSF Grant No. 0833440), semantic graphs illustrating how temperature change affects water ecology were collected from 221 students across 16 schools. The graphing task did not constrain students' use of terms, as is often done with semantic graph based assessment due to coding and scoring concerns. The graphing software used provided real-time feedback to help students learn how to construct graphs, stay on topic and effectively communicate ideas. The collected graphs were scored by human raters using assessment methods expected to boost reliability, which included adaptations of traditional holistic and propositional scoring methods, use of expert raters, topical rubrics, and criterion graphs. High levels of inter-rater reliability were achieved, demonstrating that vocabulary constraints may not be necessary after all. To investigate a new approach to automating the scoring of graphs, thirty-two different graph features characterizing graphs' structure, semantics, configuration and process of construction were then used to predict human raters' scoring of graphs in order to identify feature patterns correlated to raters' evaluations of graphs' topical accuracy and complexity. Results led to the development of a regression model able to predict raters' scoring with 77% accuracy, with 46% accuracy expected when used to score new sets of graphs, as estimated via cross-validation tests. Although such performance is comparable to other graph and essay based scoring systems, cross-context testing of the model and methods used to develop it would be needed before it could be recommended for widespread use. Still, the findings suggest techniques for improving the reliability and scalability of semantic graph based assessments without requiring constraint of how ideas are expressed.

  17. Fun cube based brain gym cognitive function assessment system.

    PubMed

    Zhang, Tao; Lin, Chung-Chih; Yu, Tsang-Chu; Sun, Jing; Hsu, Wen-Chuin; Wong, Alice May-Kuen

    2017-05-01

    The aim of this study is to design and develop a fun cube (FC) based brain gym (BG) cognitive function assessment system using the wireless sensor network and multimedia technologies. The system comprised (1) interaction devices, FCs and a workstation used as interactive tools for collecting and transferring data to the server, (2) a BG information management system responsible for managing the cognitive games and storing test results, and (3) a feedback system used for conducting the analysis of cognitive functions to assist caregivers in screening high risk groups with mild cognitive impairment. Three kinds of experiments were performed to evaluate the developed FC-based BG cognitive function assessment system. The experimental results showed that the Pearson correlation coefficient between the system's evaluation outcomes and the traditional Montreal Cognitive Assessment scores was 0.83. The average Technology Acceptance Model 2 score was close to six for 31 elderly subjects. Most subjects considered that the brain games are interesting and the FC human-machine interface is easy to learn and operate. The control group and the cognitive impairment group had statistically significant difference with respect to the accuracy of and the time taken for the brain cognitive function assessment games, including Animal Naming, Color Search, Trail Making Test, Change Blindness, and Forward / Backward Digit Span. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Reliability of patient specific instrumentation in total knee arthroplasty.

    PubMed

    Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David

    2015-12-01

    The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.

  19. Commonly used severity scores are not good predictors of mortality in sepsis from severe leptospirosis: a series of ten patients.

    PubMed

    Velissaris, Dimitrios; Karanikolas, Menelaos; Flaris, Nikolaos; Fligou, Fotini; Marangos, Markos; Filos, Kriton S

    2012-01-01

    Introduction. Severe leptospirosis, also known as Weil's disease, can cause multiorgan failure with high mortality. Scoring systems for disease severity have not been validated for leptospirosis, and there is no documented method to predict mortality. Methods. This is a case series on 10 patients admitted to ICU for multiorgan failure from severe leptospirosis. Data were collected retrospectively, with approval from the Institution Ethics Committee. Results. Ten patients with severe leptospirosis were admitted in the Patras University Hospital ICU in a four-year period. Although, based on SOFA scores, predicted mortality was over 80%, seven of 10 patients survived and were discharged from the hospital in good condition. There was no association between SAPS II or SOFA scores and mortality, but survivors had significantly lower APACHE II scores compared to nonsurvivors. Conclusion. Commonly used severity scores do not seem to be useful in predicting mortality in severe leptospirosis. Early ICU admission and resuscitation based on a goal-directed therapy protocol are recommended and may reduce mortality. However, this study is limited by retrospective data collection and small sample size. Data from large prospective studies are needed to validate our findings.

  20. Prediction for Intravenous Immunoglobulin Resistance by Using Weighted Genetic Risk Score Identified From Genome-Wide Association Study in Kawasaki Disease.

    PubMed

    Kuo, Ho-Chang; Wong, Henry Sung-Ching; Chang, Wei-Pin; Chen, Ben-Kuen; Wu, Mei-Shin; Yang, Kuender D; Hsieh, Kai-Sheng; Hsu, Yu-Wen; Liu, Shih-Feng; Liu, Xiao; Chang, Wei-Chiao

    2017-10-01

    Intravenous immunoglobulin (IVIG) is the treatment of choice in Kawasaki disease (KD). IVIG is used to prevent cardiovascular complications related to KD. However, a proportion of KD patients have persistent fever after IVIG treatment and are defined as IVIG resistant. To develop a risk scoring system based on genetic markers to predict IVIG responsiveness in KD patients, a total of 150 KD patients (126 IVIG responders and 24 IVIG nonresponders) were recruited for this study. A genome-wide association analysis was performed to compare the 2 groups and identified risk alleles for IVIG resistance. A weighted genetic risk score was calculated by the natural log of the odds ratio multiplied by the number of risk alleles. Eleven single-nucleotide polymorphisms were identified by genome-wide association study. The KD patients were categorized into 3 groups based on their calculated weighted genetic risk score. Results indicated a significant association between weighted genetic risk score (groups 3 and 4 versus group 1) and the response to IVIG (Fisher's exact P value 4.518×10 - 03 and 8.224×10 - 10 , respectively). This is the first weighted genetic risk score study based on a genome-wide association study in KD. The predictive model integrated the additive effects of all 11 single-nucleotide polymorphisms to provide a prediction of the responsiveness to IVIG. © 2017 The Authors.

  1. Associations of genetic risk scores based on adult adiposity pathways with childhood growth and adiposity measures.

    PubMed

    Monnereau, Claire; Vogelezang, Suzanne; Kruithof, Claudia J; Jaddoe, Vincent W V; Felix, Janine F

    2016-08-18

    Results from genome-wide association studies (GWAS) identified many loci and biological pathways that influence adult body mass index (BMI). We aimed to identify if biological pathways related to adult BMI also affect infant growth and childhood adiposity measures. We used data from a population-based prospective cohort study among 3,975 children with a mean age of 6 years. Genetic risk scores were constructed based on the 97 SNPs associated with adult BMI previously identified with GWAS and on 28 BMI related biological pathways based on subsets of these 97 SNPs. Outcomes were infant peak weight velocity, BMI at adiposity peak and age at adiposity peak, and childhood BMI, total fat mass percentage, android/gynoid fat ratio, and preperitoneal fat area. Analyses were performed using linear regression models. A higher overall adult BMI risk score was associated with infant BMI at adiposity peak and childhood BMI, total fat mass, android/gynoid fat ratio, and preperitoneal fat area (all p-values < 0.05). Analyses focused on specific biological pathways showed that the membrane proteins genetic risk score was associated with infant peak weight velocity, and the genetic risk scores related to neuronal developmental processes, hypothalamic processes, cyclicAMP, WNT-signaling, membrane proteins, monogenic obesity and/or energy homeostasis, glucose homeostasis, cell cycle, and muscle biology pathways were associated with childhood adiposity measures (all p-values <0.05). None of the pathways were associated with childhood preperitoneal fat area. A genetic risk score based on 97 SNPs related to adult BMI was associated with peak weight velocity during infancy and general and abdominal fat measurements at the age of 6 years. Risk scores based on genetic variants linked to specific biological pathways, including central nervous system and hypothalamic processes, influence body fat development from early life onwards.

  2. STEM-based workbook: Enhancing students' STEM competencies on lever system

    NASA Astrophysics Data System (ADS)

    Sejati, Binar Kasih; Firman, Harry; Kaniawati, Ida

    2017-05-01

    Twenty-first century is a century of technology, a rapid development of scientific studies and technology make them relied heavily on each other. This research investigated about the effect of STEM-based workbook in enhancing students' STEM competencies in terms of knowledge understanding, problem solving skill, innovative abilities, and responsibility. The workbook was tried on 24 students that applied engineering design processes together with mathematics and science knowledge to design and create an egg cracker. The result showed that the implementation of STEM-based workbook on lever system in human body is effective to improve students' STEM competencies, it can be proven by students' result on their knowledge understanding improvement which can be seen from normalized gain () score is 0.41 and categorized as medium improvement, students' problem solving skill is also improving where it obtained a medium improvement with normalized gain as much as 0.45. Innovative abilities also encountered an the improvement, the workbook analysis obtained a higher score which means students can be more innovative after finishing their workbook. Last, students' responsibility is keep improving day by day, students' effort gain the highest score it means that the students become more responsible after implementation of STEM-based workbook. All of the results are supported with the response of students towards STEM-based workbook implementation which showed positive response in all indicators.

  3. Validity of Walk Score® as a measure of neighborhood walkability in Japan.

    PubMed

    Koohsari, Mohammad Javad; Sugiyama, Takemi; Hanibuchi, Tomoya; Shibata, Ai; Ishii, Kaori; Liao, Yung; Oka, Koichiro

    2018-03-01

    Objective measures of environmental attributes have been used to understand how neighborhood environments relate to physical activity. However, this method relies on detailed spatial data, which are often not easily available. Walk Score® is a free, publicly available web-based tool that shows how walkable a given location is based on objectively-derived proximity to several types of local destinations and street connectivity. To date, several studies have tested the concurrent validity of Walk Score as a measure of neighborhood walkability in the USA and Canada. However, it is unknown whether Walk Score is a valid measure in other regions. The current study examined how Walk Score is correlated with objectively-derived attributes of neighborhood walkability, for residential addresses in Japan. Walk Scores were obtained for 1072 residential addresses in urban and rural areas in Japan. Five environmental attributes (residential density, intersection density, number of local destinations, sidewalk availability, and access to public transportation) were calculated using geographic information systems for each address. Pearson's correlation coefficients between Walk Score and these environmental attributes were calculated (conducted in May 2017). Significant positive correlations were observed between Walk Score and environmental attributes relevant to walking. Walk Score was most closely associated with intersection density ( r  = 0.82) and with the number of local destinations ( r  = 0.77). Walk Score appears to be a valid measure of neighborhood walkability in Japan. Walk Score will allow urban designers and public health practitioners to identify walkability of local areas without relying on detailed geographic data.

  4. Simulation-based coefficients for adjusting climate impact on energy consumption of commercial buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Na; Makhmalbaf, Atefe; Srivastava, Viraj

    This paper presents a new technique for and the results of normalizing building energy consumption to enable a fair comparison among various types of buildings located near different weather stations across the U.S. The method was developed for the U.S. Building Energy Asset Score, a whole-building energy efficiency rating system focusing on building envelope, mechanical systems, and lighting systems. The Asset Score is calculated based on simulated energy use under standard operating conditions. Existing weather normalization methods such as those based on heating and cooling degrees days are not robust enough to adjust all climatic factors such as humidity andmore » solar radiation. In this work, over 1000 sets of climate coefficients were developed to separately adjust building heating, cooling, and fan energy use at each weather station in the United States. This paper also presents a robust, standardized weather station mapping based on climate similarity rather than choosing the closest weather station. This proposed simulated-based climate adjustment was validated through testing on several hundreds of thousands of modeled buildings. Results indicated the developed climate coefficients can isolate and adjust for the impacts of local climate for asset rating.« less

  5. A Modified Radiosurgery-Based Arteriovenous Malformation Grading Scale and Its Correlation With Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wegner, Rodney E.; Oysul, Kaan; Pollock, Bruce E.

    Purpose: The Pittsburgh radiosurgery-based arteriovenous malformation (AVM) grading scale was developed to predict patient outcomes after radiosurgery and was later modified with location as a two-tiered variable (deep vs. other). The purpose of this study was to test the modified radiosurgery-based AVM score in a separate set of AVM patients managed with radiosurgery. Methods and Materials: The AVM score is calculated as follows: AVM score = (0.1)(volume, cc) + (0.02)(age, years) + (0.5)(location; frontal/temporal/parietal/occipital/intraventricular/corpus callosum/cerebellar = 0, basal ganglia/thalamus/brainstem = 1). Testing of the modified system was performed on 293 patients having AVM radiosurgery from 1992 to 2004 at themore » University of Pittsburgh with dose planning based on a combination of stereotactic angiography and MRI. The median patient age was 38 years, the median AVM volume was 3.3 cc, and 57 patients (19%) had deep AVMs. The median modified AVM score was 1.25. The median patient follow-up was 39 months. Results: The modified AVM scale correlated with the percentage of patients with AVM obliteration without new deficits ({<=}1.00, 62%; 1.01-1.50, 51%; 1.51-2.00, 53%; and >2.00, 32%; F = 11.002, R{sup 2} = 0.8117, p = 0.001). Linear regression also showed a statistically significant correlation between outcome and dose prescribed to the margin (F = 25.815, p <0.001). Conclusions: The modified radiosurgery-based AVM grading scale using location as a two-tiered variable correlated with outcomes when tested on a cohort of patients who underwent both angiography and MRI for dose planning. This system can be used to guide choices among observation, endovascular, surgical, and radiosurgical management strategies for individual AVM patients.« less

  6. Measuring Equity in Access to Pharmaceutical Services Using Concentration Curve; Model Development.

    PubMed

    Davari, Majid; Khorasani, Elahe; Bakhshizade, Zahra; Jafarian Jazi, Marzie; Ghaffari Darab, Mohsen; Maracy, Mohammad Reza

    2015-01-01

    This paper has two objectives. First, it establishes a model for scoring the access to pharmaceutical services. Second, it develops a model for measuring socioeconomic indicators independent of the time and place of study. These two measures are used for measuring equity in access to pharmaceutical services using concentration curve. We prepared an open-ended questionnaire and distributed it to academic experts to get their ideas to form access indicators and assign score to each indicator based on the pharmaceutical system. An extensive literature review was undertaken for the selection of indicators in order to determine the socioeconomic status (SES) of individuals. Experts' opinions were also considered for scoring these indicators. These indicators were weighted by the Stepwise Adoption of Weights and were used to develop a model for measuring SES independent of the time and place of study. Nine factors were introduced for assessing the access to pharmaceutical services, based on pharmaceutical systems in middle-income countries. Five indicators were selected for determining the SES of individuals. A model for income classification based on poverty line was established. Likewise, a model for scoring home status based on national minimum wage was introduced. In summary, five important findings emerged from this study. These findings may assist researchers in measuring equity in access to pharmaceutical services and also could help them to apply a model for determining SES independent of the time and place of study. These also could provide a good opportunity for researchers to compare the results of various studies in a reasonable way; particularly in middle-income countries.

  7. A Genomic Score Prognostic of Outcome in Trauma Patients

    PubMed Central

    Warren, H Shaw; Elson, Constance M; Hayden, Douglas L; Schoenfeld, David A; Cobb, J Perren; Maier, Ronald V; Moldawer, Lyle L; Moore, Ernest E; Harbrecht, Brian G; Pelak, Kimberly; Cuschieri, Joseph; Herndon, David N; Jeschke, Marc G; Finnerty, Celeste C; Brownstein, Bernard H; Hennessy, Laura; Mason, Philip H; Tompkins, Ronald G

    2009-01-01

    Traumatic injuries frequently lead to infection, organ failure, and death. Health care providers rely on several injury scoring systems to quantify the extent of injury and to help predict clinical outcome. Physiological, anatomical, and clinical laboratory analytic scoring systems (Acute Physiology and Chronic Health Evaluation [APACHE], Injury Severity Score [ISS]) are utilized, with limited success, to predict outcome following injury. The recent development of techniques for measuring the expression level of all of a person’s genes simultaneously may make it possible to develop an injury scoring system based on the degree of gene activation. We hypothesized that a peripheral blood leukocyte gene expression score could predict outcome, including multiple organ failure, following severe blunt trauma. To test such a scoring system, we measured gene expression of peripheral blood leukocytes from patients within 12 h of traumatic injury. cRNA derived from whole blood leukocytes obtained within 12 h of injury provided gene expression data for the entire genome that were used to create a composite gene expression score for each patient. Total blood leukocytes were chosen because they are active during inflammation, which is reflective of poor outcome. The gene expression score combines the activation levels of all the genes into a single number which compares the patient’s gene expression to the average gene expression in uninjured volunteers. Expression profiles from healthy volunteers were averaged to create a reference gene expression profile which was used to compute a difference from reference (DFR) score for each patient. This score described the overall genomic response of patients within the first 12 h following severe blunt trauma. Regression models were used to compare the association of the DFR, APACHE, and ISS scores with outcome. We hypothesized that patients with a total gene response more different from uninjured volunteers would tend to have poorer outcome than those more similar. Our data show that for measures of poor outcome, such as infections, organ failures, and length of hospital stay, this is correct. DFR scores were associated significantly with adverse outcome, including multiple organ failure, duration of ventilation, length of hospital stay, and infection rate. The association remained significant after adjustment for injury severity as measured by APACHE or ISS. A single score representing changes in gene expression in peripheral blood leukocytes within hours of severe blunt injury is associated with adverse clinical outcomes that develop later in the hospital course. Assessment of genome-wide gene expression provides useful clinical information that is different from that provided by currently utilized anatomic or physiologic scores. PMID:19593405

  8. The use of children's drawings in the evaluation and treatment of child sexual, emotional, and physical abuse.

    PubMed

    Peterson, L W; Hardin, M; Nitsch, M J

    1995-05-01

    Primary care physicians can be instrumental in the initial identification of potential sexual, emotional, and physical abuse of children. We reviewed the use of children's artwork as a method of communicating individual and family functioning. A quantitative method of analyzing children's artwork provides more reliability and validity than some methods used previously. A new scoring system was developed that uses individual human figure drawings and kinetic family drawings. This scoring system was based on research with 842 children (341 positively identified as sexually molested, 252 positively not sexually molested but having emotional or behavioral problems, and 249 "normal" public school children). This system is more comprehensive than previous systems of assessment of potential abuse.

  9. Systematic screening of common wastewater-marking pharmaceuticals in urban aquatic environments: implications for environmental risk control.

    PubMed

    Zhou, Haidong; Zhang, Qingjun; Wang, Xuelian; Zhang, Qianqian; Ma, Lixin; Zhan, Yong

    2014-01-01

    In this report, we refer to pharmaceuticals that are widespread in the urban aquatic environment and that mainly originate from wastewater treatment plants or non-point source sewage as "wastewater-marking pharmaceuticals" (WWMPs). To some extent, they reflect the condition or trend of water contamination and also contribute to aquatic environmental risk assessment. The method reported here for screening typical WWMPs was proposed based on academic concerns about them and their concentrations present in the urban aquatic environment, as well as their properties of accumulation, persistence, eco-toxicity and related environmental risks caused by them. The screening system consisted of an initial screening system and a further screening system. In the former, pharmaceuticals were categorised into different evaluation levels, and in the latter, each pharmaceutical was given a normalised final evaluation score, which was the sum of every score for its properties of accumulation, persistence, eco-toxicity and environmental risk in the aquatic environment. The system was applied to 126 pharmaceuticals frequently detected in the aquatic environment. In the initial screening procedure, five pharmaceuticals were classified into the "high" category, 16 pharmaceuticals into the "medium" category, 15 pharmaceuticals into the "low" category and 90 pharmaceuticals into the "very low" category. Subsequently, further screening were conducted on 36 pharmaceuticals considered as being of "high", "medium" and "low" categories in the former system. We identified 7 pharmaceuticals with final evaluation scores of 1-10, 10 pharmaceuticals with scores of 11-15, 15 pharmaceuticals with scores from 16 to 20 and 4 pharmaceuticals with scores above 21. The results showed that this screening system could contribute to the effective selection of target WWMPs, which would be important for spatial-temporal dynamics, transference and pollution control of pharmaceuticals in the urban aquatic environment. However, there remains a number of pharmaceutical parameters with measured data gaps, such as organic carbon adsorption coefficients and bioconcentration factors, which, if filled, would improve the accuracy of the screening system.

  10. Knowledge based ranking algorithm for comparative assessment of post-closure care needs of closed landfills.

    PubMed

    Sizirici, Banu; Tansel, Berrin; Kumar, Vivek

    2011-06-01

    Post-closure care (PCC) activities at landfills include cap maintenance; water quality monitoring; maintenance and monitoring of the gas collection/control system, leachate collection system, groundwater monitoring wells, and surface water management system; and general site maintenance. The objective of this study was to develop an integrated data and knowledge based decision making tool for preliminary estimation of PCC needs at closed landfills. To develop the decision making tool, 11 categories of parameters were identified as critical areas which could affect future PCC needs. Each category was further analyzed by detailed questions which could be answered with limited data and knowledge about the site, its history, location, and site specific characteristics. Depending on the existing knowledge base, a score was assigned to each question (on a scale 1-10, as 1 being the best and 10 being the worst). Each category was also assigned a weight based on its relative importance on the site conditions and PCC needs. The overall landfill score was obtained from the total weighted sum attained. Based on the overall score, landfill conditions could be categorized as critical, acceptable, or good. Critical condition indicates that the landfill may be a threat to the human health and the environment and necessary steps should be taken. Acceptable condition indicates that the landfill is currently stable and the monitoring should be continued. Good condition indicates that the landfill is stable and the monitoring activities can be reduced in the future. The knowledge base algorithm was applied to two case study landfills for preliminary assessment of PCC performance. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Parametric study of sensor placement for vision-based relative navigation system of multiple spacecraft

    NASA Astrophysics Data System (ADS)

    Jeong, Junho; Kim, Seungkeun; Suk, Jinyoung

    2017-12-01

    In order to overcome the limited range of GPS-based techniques, vision-based relative navigation methods have recently emerged as alternative approaches for a high Earth orbit (HEO) or deep space missions. Therefore, various vision-based relative navigation systems use for proximity operations between two spacecraft. For the implementation of these systems, a sensor placement problem can occur on the exterior of spacecraft due to its limited space. To deal with the sensor placement, this paper proposes a novel methodology for a vision-based relative navigation based on multiple position sensitive diode (PSD) sensors and multiple infrared beacon modules. For the proposed method, an iterated parametric study is used based on the farthest point optimization (FPO) and a constrained extended Kalman filter (CEKF). Each algorithm is applied to set the location of the sensors and to estimate relative positions and attitudes according to each combination by the PSDs and beacons. After that, scores for the sensor placement are calculated with respect to parameters: the number of the PSDs, number of the beacons, and accuracy of relative estimates. Then, the best scoring candidate is determined for the sensor placement. Moreover, the results of the iterated estimation show that the accuracy improves dramatically, as the number of the PSDs increases from one to three.

  12. Evaluation of scoring models for identifying the need for therapeutic intervention of upper gastrointestinal bleeding: A new prediction score model for Japanese patients.

    PubMed

    Iino, Chikara; Mikami, Tatsuya; Igarashi, Takasato; Aihara, Tomoyuki; Ishii, Kentaro; Sakamoto, Jyuichi; Tono, Hiroshi; Fukuda, Shinsaku

    2016-11-01

    Multiple scoring systems have been developed to predict outcomes in patients with upper gastrointestinal bleeding. We determined how well these and a newly established scoring model predict the need for therapeutic intervention, excluding transfusion, in Japanese patients with upper gastrointestinal bleeding. We reviewed data from 212 consecutive patients with upper gastrointestinal bleeding. Patients requiring endoscopic intervention, operation, or interventional radiology were allocated to the therapeutic intervention group. Firstly, we compared areas under the curve for the Glasgow-Blatchford, Clinical Rockall, and AIMS65 scores. Secondly, the scores and factors likely associated with upper gastrointestinal bleeding were analyzed with a logistic regression analysis to form a new scoring model. Thirdly, the new model and the existing model were investigated to evaluate their usefulness. Therapeutic intervention was required in 109 patients (51.4%). The Glasgow-Blatchford score was superior to both the Clinical Rockall and AIMS65 scores for predicting therapeutic intervention need (area under the curve, 0.75 [95% confidence interval, 0.69-0.81] vs 0.53 [0.46-0.61] and 0.52 [0.44-0.60], respectively). Multivariate logistic regression analysis retained seven significant predictors in the model: systolic blood pressure <100 mmHg, syncope, hematemesis, hemoglobin <10 g/dL, blood urea nitrogen ≥22.4 mg/dL, estimated glomerular filtration rate ≤ 60 mL/min per 1.73 m 2 , and antiplatelet medication. Based on these variables, we established a new scoring model with superior discrimination to those of existing scoring systems (area under the curve, 0.85 [0.80-0.90]). We developed a superior scoring model for identifying therapeutic intervention need in Japanese patients with upper gastrointestinal bleeding. © 2016 Japan Gastroenterological Endoscopy Society.

  13. Upper Gastrointestinal Hemorrhage: Development of the Severity Score.

    PubMed

    Chaikitamnuaychok, Rangson; Patumanond, Jayanton

    2012-12-01

    Emergency endoscopy for every patient with upper gastrointestinal hemorrhage is not possible in many medical centers. Simple guidelines to select patients for emergency endoscopy are lacking. The aim of the present report is to develop a simple scoring system to classify upper gastrointestinal hemorrhage (UGIH) severity based on patient clinical profiles at the emergency departments. Retrospective data of patients with UGIH in a university affiliated hospital were analyzed. Patients were criterion-classified into 3 severity levels: mild, moderate and severe. Clinical and laboratory information were compared among the 3 groups. Significant parameters were selected as indicators of severity. Coefficients of significant multivariable parameters were transformed into item scores, which added up as individual severity scores. The scores were used to classify patients into 3 urgency levels: non-urgent, urgent and emergent groups. Score-classification and criterion-classification were compared. Significant parameters in the model were age ≥ 60 years, pulse rate ≥ 100/min, systolic blood pressure < 100 mmHg, hemoglobin < 10 g/dL, blood urea nitrogen ≥ 35 mg/dL, presence of cirrhosis and hepatic failure. The score ranged from 0 to 27, and classifying patients into 3 urgency groups: non-urgent (score < 4, n = 215, 21.2%), urgent (score 4 - 16, n = 677, 66.9%) and emergent (score > 16, n = 121, 11.9%). The score correctly classified 81.4% of the patients into their original (criterion-classified) severity groups. Under-estimation (7.5%) and over-estimation (11.1%) were clinically acceptable. Our UGIH severity scoring system classified patients into 3 urgency groups: non-urgent, urgent and emergent, with clinically acceptable small number of under- and over-estimations. Its discriminative ability and precision should be validated before adopting into clinical practice.

  14. Relationship between the logistic EuroSCORE and the Society of Thoracic Surgeons Predicted Risk of Mortality score in patients implanted with the CoreValve ReValving system--a Bern-Rotterdam Study.

    PubMed

    Piazza, Nicolo; Wenaweser, Peter; van Gameren, Menno; Pilgrim, Thomas; Tzikas, Apostolos; Tsikas, Apostolos; Otten, Amber; Nuis, Rutger; Onuma, Yoshinobu; Cheng, Jin Ming; Kappetein, A Pieter; Boersma, Eric; Juni, Peter; de Jaegere, Peter; Windecker, Stephan; Serruys, Patrick W

    2010-02-01

    Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or "inoperable" patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% +/- 13.9% vs STS 6.7% +/- 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES > or =15%, 16% had an STS > or =10%, and 40% had an LES > or =20% or STS > or =10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  15. Automatic Diagnosis of Obstructive Sleep Apnea/Hypopnea Events Using Respiratory Signals.

    PubMed

    Aydoğan, Osman; Öter, Ali; Güney, Kerim; Kıymık, M Kemal; Tuncel, Deniz

    2016-12-01

    Obstructive sleep apnea is a sleep disorder which may lead to various results. While some studies used real-time systems, there are also numerous studies which focus on diagnosing Obstructive Sleep Apnea via signals obtained by polysomnography from apnea patients who spend the night in sleep laboratory. The mean, frequency and power of signals obtained from patients are frequently used. Obstructive Sleep Apnea of 74 patients were scored in this study. A visual-scoring based algorithm and a morphological filter via Artificial Neural Networks were used in order to diagnose Obstructive Sleep Apnea. After total accuracy of scoring was calculated via both methods, it was compared with visual scoring performed by the doctor. The algorithm used in the diagnosis of obstructive sleep apnea reached an average accuracy of 88.33 %, while Artificial Neural Networks and morphological filter method reached a success of 87.28 %. Scoring success was analyzed after it was grouped based on apnea/hypopnea. It is considered that both methods enable doctors to reduce time and costs in the diagnosis of Obstructive Sleep Apnea as well as ease of use.

  16. Predictive value of Tokuhashi scoring systems in spinal metastases, focusing on various primary tumor groups: evaluation of 448 patients in the Aarhus spinal metastases database.

    PubMed

    Wang, Miao; Bünger, Cody Eric; Li, Haisheng; Wu, Chunsen; Høy, Kristian; Niedermann, Bent; Helmig, Peter; Wang, Yu; Jensen, Anders Bonde; Schättiger, Katrin; Hansen, Ebbe Stender

    2012-04-01

    We conducted a prospective cohort study of 448 patients with spinal metastases from a variety of cancer groups. To determine the specific predictive value of the Tokuhashi scoring system (T12) and its revised version (T15) in spinal metastases of various primary tumors. The life expectancy of patients with spinal metastases is one of the most important factors in selecting the treatment modality. Tokuhashi et al formulated a prognostic scoring system with a total sum of 12 points for preoperative prediction of life expectancy in 1990 and revised it in 2005 to a total sum of 15 points. There is a lack of knowledge about the specific predictive value of those scoring systems in patients with spinal metastases from a variety of cancer groups. We included 448 patients with vertebral metastases who underwent surgical treatment during November 1992 to November 2009 in Aarhus University Hospital NBG. Data were retrieved from Aarhus Metastases Database. Scores based on T12 and T15 were calculated prospectively for each patient. We divided all the patients into different groups dictated by the site of their primary tumor. Predictive value and accuracy rate of the 2 scoring systems were compared in each cancer group. Both the T12 and T15 scoring systems showed statistically significant predictive value when the 448 patients were analyzed in total (T12, P < 0.0001; T15, P < 0.0001). The accuracy rate was significantly higher in T15 (P < 0.0001) than in T12. The further analyses by primary cancer groups showed that the predictive value of T12 and T15 was primarily determined by the prostate (P = 0.0003) and breast group (P = 0.0385). Only T12 displayed predictive value in the colon group (P = 0.0011). Neither of the scoring systems showed significant predictive value in the lung (P > 0.05), renal (P > 0.05), or miscellaneous primary tumor groups (P > 0.05). The accuracy rate of prognosis in T15 was significantly improved in the prostate (P = 0.0032) and breast group (P < 0.0001). Both T12 and T15 showed significant predictive value in patients with spinal metastases. T15 has a statistically higher accuracy rate than T12. Among the various cancer groups, the 2 scoring systems are especially reliable in prostate and breast metastases groups. T15 is recommended as superior to T12 because of its higher accuracy rate.

  17. Locating binding poses in protein-ligand systems using reconnaissance metadynamics

    PubMed Central

    Söderhjelm, Pär; Tribello, Gareth A.; Parrinello, Michele

    2012-01-01

    A molecular dynamics-based protocol is proposed for finding and scoring protein-ligand binding poses. This protocol uses the recently developed reconnaissance metadynamics method, which employs a self-learning algorithm to construct a bias that pushes the system away from the kinetic traps where it would otherwise remain. The exploration of phase space with this algorithm is shown to be roughly six to eight times faster than unbiased molecular dynamics and is only limited by the time taken to diffuse about the surface of the protein. We apply this method to the well-studied trypsin–benzamidine system and show that we are able to refind all the poses obtained from a reference EADock blind docking calculation. These poses can be scored based on the length of time the system remains trapped in the pose. Alternatively, one can perform dimensionality reduction on the output trajectory and obtain a map of phase space that can be used in more expensive free-energy calculations. PMID:22440749

  18. Development of formula varsity race car chassis

    NASA Astrophysics Data System (ADS)

    Abdullah, M. A.; Mansur, M. R.; Tamaldin, N.; Thanaraj, K.

    2013-12-01

    Three chassis designs have been developed using commercial computer aided design (CAD) software. The design is based on the specifications of UTeM Formula VarsityTM 2012 (FV2012). The selection of the design is derived from weighted matrix which consists of reliability, cost, time consumption and weight. The score of the matrix is formulated based on relative weighted factor among the selections. All three designs are then fabricated using selected materials available. The actual cost, time consumption and weight of the chassis's are compared with the theoretical weighted scores. Standard processes of cuttings, fittings and welding are performed in chassis mock up and fabrication. The chassis is later assembled together with suspension systems, steering linkages, brake systems, engine system, and drive shaft systems. Once the chassis is assembled, the studies of driver's ergonomic and part accessibility are performed. The completion in final fittings and assembly of the race car and its reliability demonstrate an outstanding design for manufacturing (DFM) practices of the chassis.

  19. Locating binding poses in protein-ligand systems using reconnaissance metadynamics.

    PubMed

    Söderhjelm, Pär; Tribello, Gareth A; Parrinello, Michele

    2012-04-03

    A molecular dynamics-based protocol is proposed for finding and scoring protein-ligand binding poses. This protocol uses the recently developed reconnaissance metadynamics method, which employs a self-learning algorithm to construct a bias that pushes the system away from the kinetic traps where it would otherwise remain. The exploration of phase space with this algorithm is shown to be roughly six to eight times faster than unbiased molecular dynamics and is only limited by the time taken to diffuse about the surface of the protein. We apply this method to the well-studied trypsin-benzamidine system and show that we are able to refind all the poses obtained from a reference EADock blind docking calculation. These poses can be scored based on the length of time the system remains trapped in the pose. Alternatively, one can perform dimensionality reduction on the output trajectory and obtain a map of phase space that can be used in more expensive free-energy calculations.

  20. A highly sensitive and specific combined clinical and sonographic score to diagnose appendicitis.

    PubMed

    Reddy, Swathi B; Kelleher, Michael; Bokhari, S A Jamal; Davis, Kimberly A; Schuster, Kevin M

    2017-10-01

    Computed tomography (CT) scanning reduces the negative appendectomy rate however it exposes the patient to ionizing radiation. Ultrasound (US) does not carry this risk but may be nondiagnostic. We hypothesized that a clinical-US scoring system would improve diagnostic accuracy. We conducted a retrospective review of all patients (age, >15 years) who presented through the emergency department with suspected appendicitis and underwent initial US. A US score was developed using odds ratios for appendicitis given appendiceal diameter, compressibility, hyperemia, free fluid, and focal or diffuse tenderness. The US score was then combined with the Alvarado score. Final diagnosis of appendicitis was assigned by pathology reports. Three hundred patients who underwent US as initial imaging were identified. Thirty-two patients with evident nonappendiceal pathology on US were excluded. In 114 (38%), the appendix was not visualized and partially visualized in 36 (12%). Fifty-seven (21.3%) had an appendectomy with 1 (1.7%) negative. Six nonvisualized appendicies underwent appendectomy, with no negative cases. Sensitivity and specificity for the sonographic score were 86% and 90%, respectively, at a score of 1.5. The combined score demonstrated 98% sensitivity and 82% specificity at 6.5, and 95% sensitivity, and 87% specificity at a score of 7.5. Sensitivity and specificity were confirmed by bootstrap resampling for validation. Area under receiver operating characteristic (ROC) curves for our new US score were similar to the ROC curve for the Alvarado score (91.9 and 91.1, p = 0.8). The combined US and Alvarado score yielded an area under the ROC curve of 97.1, significantly better than either score alone (p = 0.017 and p < 0.001, respectively). Our scoring system based entirely on US findings was highly sensitive and specific for appendicitis, and it significantly improved when combined with the Alvarado score. After prospective evaluation, the combined US-Alvarado score might replace the need for computed tomography imaging in a majority of patients. Diagnostic Test, Level III.

  1. Design and internal validation of an obstetric early warning score: secondary analysis of the Intensive Care National Audit and Research Centre Case Mix Programme database.

    PubMed

    Carle, C; Alexander, P; Columb, M; Johal, J

    2013-04-01

    We designed and internally validated an aggregate weighted early warning scoring system specific to the obstetric population that has the potential for use in the ward environment. Direct obstetric admissions from the Intensive Care National Audit and Research Centre's Case Mix Programme Database were randomly allocated to model development (n = 2240) or validation (n = 2200) sets. Physiological variables collected during the first 24 h of critical care admission were analysed. Logistic regression analysis for mortality in the model development set was initially used to create a statistically based early warning score. The statistical score was then modified to create a clinically acceptable early warning score. Important features of this clinical obstetric early warning score are that the variables are weighted according to their statistical importance, a surrogate for the FI O2 /Pa O2 relationship is included, conscious level is assessed using a simplified alert/not alert variable, and the score, trigger thresholds and response are consistent with the new non-obstetric National Early Warning Score system. The statistical and clinical early warning scores were internally validated using the validation set. The area under the receiver operating characteristic curve was 0.995 (95% CI 0.992-0.998) for the statistical score and 0.957 (95% CI 0.923-0.991) for the clinical score. Pre-existing empirically designed early warning scores were also validated in the same way for comparison. The area under the receiver operating characteristic curve was 0.955 (95% CI 0.922-0.988) for Swanton et al.'s Modified Early Obstetric Warning System, 0.937 (95% CI 0.884-0.991) for the obstetric early warning score suggested in the 2003-2005 Report on Confidential Enquiries into Maternal Deaths in the UK, and 0.973 (95% CI 0.957-0.989) for the non-obstetric National Early Warning Score. This highlights that the new clinical obstetric early warning score has an excellent ability to discriminate survivors from non-survivors in this critical care data set. Further work is needed to validate our new clinical early warning score externally in the obstetric ward environment. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  2. Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.

    PubMed

    Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina

    2004-10-01

    We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.

  3. Coronary artery calcium: a multi-institutional, multimanufacturer international standard for quantification at cardiac CT.

    PubMed

    McCollough, Cynthia H; Ulzheimer, Stefan; Halliburton, Sandra S; Shanneik, Kaiss; White, Richard D; Kalender, Willi A

    2007-05-01

    To develop a consensus standard for quantification of coronary artery calcium (CAC). A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.

  4. Measuring the impact of diagnostic decision support on the quality of clinical decision making: development of a reliable and valid composite score.

    PubMed

    Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F

    2003-01-01

    Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.

  5. Creation and validation of a novel body condition scoring method for the magellanic penguin (Spheniscus magellanicus) in the zoo setting.

    PubMed

    Clements, Julie; Sanchez, Jessica N

    2015-11-01

    This research aims to validate a novel, visual body scoring system created for the Magellanic penguin (Spheniscus magellanicus) suitable for the zoo practitioner. Magellanics go through marked seasonal fluctuations in body mass gains and losses. A standardized multi-variable visual body condition guide may provide a more sensitive and objective assessment tool compared to the previously used single variable method. Accurate body condition scores paired with seasonal weight variation measurements give veterinary and keeper staff a clearer understanding of an individual's nutritional status. San Francisco Zoo staff previously used a nine-point body condition scale based on the classic bird standard of a single point of keel palpation with the bird restrained in hand, with no standard measure of reference assigned to each scoring category. We created a novel, visual body condition scoring system that does not require restraint to assesses subcutaneous fat and muscle at seven body landmarks using illustrations and descriptive terms. The scores range from one, the least robust or under-conditioned, to five, the most robust, or over-conditioned. The ratio of body weight to wing length was used as a "gold standard" index of body condition and compared to both the novel multi-variable and previously used single-variable body condition scores. The novel multi-variable scale showed improved agreement with weight:wing ratio compared to the single-variable scale, demonstrating greater accuracy, and reliability when a trained assessor uses the multi-variable body condition scoring system. Zoo staff may use this tool to manage both the colony and the individual to assist in seasonally appropriate Magellanic penguin nutrition assessment. © 2015 Wiley Periodicals, Inc.

  6. The rat whole embryo culture assay using the Dysmorphology Score system.

    PubMed

    Zhang, Cindy; Panzica-Kelly, Julie; Augustine-Rauch, Karen

    2013-01-01

    The rat whole embryo culture (WEC) system has been used extensively for characterizing teratogenic properties of test chemicals. In this chapter, we describe the methodology for culturing rat embryos as well as a new morphological score system, the Dysmorphology Score (DMS) system for assessing morphology of mid gestation (gestational day 11) rat embryos. In contrast to the developmental stage focused scoring associated with the Brown and Fabro score system, this new score system assesses the respective degree of severity of dysmorphology, which delineates normal from abnormal morphology of specific embryonic structures and organ systems. This score system generates an approach that allows rapid identification and quantification of adverse developmental findings, making it conducive for characterization of compounds for teratogenic properties and screening activities.

  7. Morphology based scoring of chromosomal instability and its correlation with cell viability.

    PubMed

    Yadav, Shubhlata; Bhatia, Alka

    2017-09-01

    The aim of this study was to devise the quantitative scoring system for Chromosomal instability (CIN) based on morphological indicators like MPM, NB, NPB, CS, La and MN in cancer cell line and to correlate it with cell viability and death. Human hepatocellular carcinoma (HepG2) cells were treated with drugs like Diethylstilbestrol 0-100μM, Griseofulvin 0-40μg/ml, Vincristine sulphate 0-25μg/ml, Mitomycin C 0-600ng/ml, Bleomycin 0-10μg/ml, Doxorubicin 0-30μg/ml for 24h. Following this, the CIN was assessed by counting the morphological indicators like Micronuclei (MN), Nuclear Buds (NB), Nucleoplasmic bridges, Laggards, Multipolar mitosis and chromatin strings/1000 cells in Giemsa stained smears by light microscopy and by determining the percentage of aneuploid cells by flow cytometry. The cell viability was assessed by MTT assay and percentage of apoptotic cells was determined by flow cytometry. The MN and NB were most frequently seen indicators and main determinants of morphological CIN. However, the morphological CIN score did not show any correlation with cell viability and apoptosis. Aneuploidy however was found to correlate positively with cell viability and NB score in our study (P-value <0.05). The study for the 1st time attempted to develop a scoring system for CIN based on morphological parameters. However, a no correlation was observed between the later and cell viability or apoptosis. More robust techniques to quantify CIN may perhaps be more helpful in exploring the true link between CIN and cell viability in future. Copyright © 2017 Elsevier GmbH. All rights reserved.

  8. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  9. Enlisted Personnel Allocation System

    DTIC Science & Technology

    1989-03-01

    hierarchy is further subdivided into two characteristic groupings: intelligence qualifications and physical qualifications. 41 I I 7 -, S- ie p if- i - LL...weighted as 30% of the applicant’s Intelligence Qualifications score). As shown in Figure 6, a step function generates a score based on the...34 There is no aritificial time window imposed on any MOS. Any open training date within the full DEP horizon may be recommended by the optimization

  10. Meaning-Based Scoring: A Systemic Functional Linguistics Model for Automated Test Tasks

    ERIC Educational Resources Information Center

    Gleason, Jesse

    2014-01-01

    Communicative approaches to language teaching that emphasize the importance of speaking (e.g., task-based language teaching) require innovative and evidence-based means of assessing oral language. Nonetheless, research has yet to produce an adequate assessment model for oral language (Chun 2006; Downey et al. 2008). Limited by automatic speech…

  11. A novel scoring system based on common laboratory tests predicts the efficacy of TNF-inhibitor and IL-6 targeted therapy in patients with rheumatoid arthritis: a retrospective, multicenter observational study.

    PubMed

    Nakagawa, Jin; Koyama, Yoshinobu; Kawakami, Atsushi; Ueki, Yukitaka; Tsukamoto, Hiroshi; Horiuchi, Takahiko; Nagano, Shuji; Uchino, Ayumi; Ota, Toshiyuki; Akahoshi, Mitsuteru; Akashi, Koichi

    2017-08-11

    Currently, although several categories of biological disease-modifying antirheumatic drugs (bDMARDs) are available, there are few data informing selection of initial treatment for individual patients with rheumatoid arthritis (RA). Therefore, tumor necrosis factor inhibitor (TNF-i) and tocilizumab (TCZ) are treated as equivalent treatments in the recent disease management recommendations. We focused on two anticytokine therapies, TCZ and TNF-i, and aimed to develop a scoring system that predicts a better treatment for each RA patient before starting an IL-6 or a TNF-i. The expression of IL-6 and TNF-α mRNA in peripheral blood from 45 newly diagnosed RA patients was measured by DNA microarrays to evaluate cytokine activation. Next, laboratory indices immediately before commencing treatment and disease activity score improvement ratio after 6 months in 98 patients treated with TCZ or TNF-i were retrospectively analyzed. Some indices correlated with TCZ efficacy were selected and their cutoff values were defined by receiver operating characteristic (ROC) analysis to develop a scoring system to discriminate between individuals more likely to respond to TCZ or TNF-i. The validity of the scoring system was verified in these 98 patients and an additional 228 patients. There was significant inverse correlation between the expression of IL-6 and TNF-α mRNA in newly diagnosed RA patients. The analysis of 98 patients revealed significant correlation between TCZ efficacy and platelet counts, hemoglobin, aspartate aminotransferase, and alanine aminotransferase; in contrast, there was no similar correlation in the TNF-i group. The cutoff values were defined by ROC analysis to develop a scoring system (1 point/item, maximum of 4 points). A good TCZ response was predicted if the score was ≥2; in contrast, TNF-i seemed to be preferable if the score was ≤1. Similar results were obtained in a validation study of an additional 228 patients. If the case scored ≥3, the good responder rates of TCZ/TNF-i were 75.0%/37.9% (p < 0.01) and the non-responder rates were 3.1%/27.6% (p < 0.01), respectively. The score is easily calculated from common laboratory results. It appears useful for identifying a better treatment at the time of selecting either an IL-6 or a TNF inhibitor.

  12. Spatial analysis of schizotypal personality traits in Chinese male youths: evidence from a GIS-based analysis of Sichuan

    PubMed Central

    2014-01-01

    Background Schizotypal personality traits are associated with schizophrenia spectrum disorders, stating that schizotypal traits may represent a “prodrome” or other developmental precursor of schizophrenia. Genetic and environmental factors both play importanxt roles in the development of schizotypal traits. Different levels of schizotypal traits across regions may be indicative of similar differences in the incidence of schizophrenia. Aim The present study identifying where in a given region, schizotypal personality traits are more or less level of schizotypal personality scores in Chinese male youth of Sichuan province. Not only for research purposes but also for the evaluation of new draft and allocation policy initiatives intended to aid recruitment of mental health employees. Methods Data from the Psychological Selection Systems for Chinese Recruits, a mental health screening system used in China, collected in 2011 (67,558 copies) were used to map spatial distribution of schizotypal personality traits using geostatistics and geographic information system (GIS) techniques. Correlation analyses were conducted to explore the effects of years of education and illiterate rate on schizotypal personality traits. Results Maps for three schizotypal personality clinical scales (dissociative, Dit; neurotic, Net and sensitive, Set) showed similar geographical trends. The highest T scores were distributed mainly in the eastern and northern counties of Sichuan, with scores decreasing successively from east to west, with the eastern counties generally showing higher scores. Correlation analysis showed that t-scores of Set were negatively correlated with years of education, whereas t-scores of Net were negatively correlated with illiteracy rate. Conclusions Schizotypal personality traits in male youth showed specific geographical trends in Sichuan province, providing some evidence that kriging based on GIS can be used to geographically localize genetic and environmental factors associated with schizotypal personality traits. This approach could be used to help allocate public health resources to specific areas and could also have personnel selection applications. PMID:24423022

  13. Evaluation of a prognostic scoring system based on the systemic inflammatory and nutritional status of patients with locally advanced non-small-cell lung cancer treated with chemoradiotherapy.

    PubMed

    Mitsuyoshi, Takamasa; Matsuo, Yukinori; Itou, Hitoshi; Shintani, Takashi; Iizuka, Yusuke; Kim, Young Hak; Mizowaki, Takashi

    2018-01-01

    Systemic inflammation and poor nutritional status have a negative effect on the outcomes of cancer. Here, we analyzed the effects of the pretreatment inflammatory and nutritional status on clinical outcomes of locally advanced non-small-cell lung cancer (NSCLC) patients treated with chemoradiotherapy. We retrospectively reviewed 89 patients with locally advanced NSCLC treated with chemoradiotherapy between July 2006 and June 2013. Serum C-reactive protein (CRP) was assessed as an inflammatory marker, and serum albumin, body mass index (BMI) and skeletal mass index were assessed as nutritional status markers. The relationships between these markers and overall survival (OS) were assessed. The median OS was 24.6 months [95% confidence interval (CI): 19.4-39.3 months]. During follow-up, 58 patients (65%) had disease recurrence and 52 patients (58%) died. In multivariate Cox hazard analysis, CRP levels and BMI approached but did not achieve a significant association with OS (P = 0.062 and 0.094, respectively). Recursive partitioning analysis identified three prognostic groups based on hazard similarity (CRP-BMI scores): 0 = CRP < 0.3 mg/dl, 1 = CRP ≥ 0.3 mg/dl and BMI ≥ 18.5 kg/m2, and 2 = CRP ≥ 0.3 mg/dl and BMI < 18.5 kg/m2. The CRP-BMI score was significantly associated with OS (P = 0.023). Patients with scores of 0, 1 and 2 had median OS of 39.3, 24.5 and 14.5 months, respectively, and the scores also predicted the probability of receiving salvage treatment after recurrence. The CRP-BMI score is thus a simple and useful prognostic marker of clinical outcome for patients with locally advanced NSCLC treated with chemoradiotherapy. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  14. Derivation and validation of a diagnostic score based on case-mix groups to predict 30-day death or urgent readmission.

    PubMed

    van Walraven, Carl; Wong, Jenna; Forster, Alan J

    2012-01-01

    Between 5% and 10% of patients die or are urgently readmitted within 30 days of discharge from hospital. Readmission risk indexes have either excluded acute diagnoses or modelled them as multiple distinct variables. In this study, we derived and validated a score summarizing the influence of acute hospital diagnoses and procedures on death or urgent readmission within 30 days. From population-based hospital abstracts in Ontario, we randomly sampled 200 000 discharges between April 2003 and March 2009 and determined who had been readmitted urgently or died within 30 days of discharge. We used generalized estimating equation modelling, with a sample of 100 000 patients, to measure the adjusted association of various case-mix groups (CMGs-homogenous groups of acute care inpatients with similar clinical and resource-utilization characteristics) with 30-day death or urgent readmission. This final model was transformed into a scoring system that was validated in the remaining 100 000 patients. Patients in the derivation set belonged to 1 of 506 CMGs and had a 6.8% risk of 30-day death or urgent readmission. Forty-seven CMG codes (more than half of which were directly related to chronic diseases) were independently associated with this outcome, which led to a CMG score that ranged from -6 to 7 points. The CMG score was significantly associated with 30-day death or urgent readmission (unadjusted odds ratio for a 1-point increase in CMG score 1.52, 95% confidence interval [CI] 1.49-1.56). Alone, the CMG score was only moderately discriminative (C statistic 0.650, 95% CI 0.644-0.656). However, when the CMG score was added to a validated risk index for death or readmission, the C statistic increased to 0.759 (95% CI 0.753-0.765). The CMG score was well calibrated for 30-day death or readmission. In this study, we developed a scoring system for acute hospital diagnoses and procedures that could be used as part of a risk-adjustment methodology for analyses of postdischarge outcomes.

  15. Scoring systems for outcome prediction in patients with perforated peptic ulcer.

    PubMed

    Thorsen, Kenneth; Søreide, Jon Arne; Søreide, Kjetil

    2013-04-10

    Patients with perforated peptic ulcer (PPU) often present with acute, severe illness that carries a high risk for morbidity and mortality. Mortality ranges from 3-40% and several prognostic scoring systems have been suggested. The aim of this study was to review the available scoring systems for PPU patients, and to assert if there is evidence to prefer one to the other. We searched PubMed for the mesh terms "perforated peptic ulcer", "scoring systems", "risk factors", "outcome prediction", "mortality", "morbidity" and the combinations of these terms. In addition to relevant scores introduced in the past (e.g. Boey score), we included recent studies published between January 2000 and December 2012) that reported on scoring systems for prediction of morbidity and mortality in PPU patients. A total of ten different scoring systems used to predict outcome in PPU patients were identified; the Boey score, the Hacettepe score, the Jabalpur score the peptic ulcer perforation (PULP) score, the ASA score, the Charlson comorbidity index, the sepsis score, the Mannheim Peritonitis Index (MPI), the Acute physiology and chronic health evaluation II (APACHE II), the simplified acute physiology score II (SAPS II), the Mortality probability models II (MPM II), the Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity physical sub-score (POSSUM-phys score). Only four of the scores were specifically constructed for PPU patients. In five studies the accuracy of outcome prediction of different scoring systems was evaluated by receiver operating characteristics curve (ROC) analysis, and the corresponding area under the curve (AUC) among studies compared. Considerable variation in performance both between different scores and between different studies was found, with the lowest and highest AUC reported between 0.63 and 0.98, respectively. While the Boey score and the ASA score are most commonly used to predict outcome for PPU patients, considerable variations in accuracy for outcome prediction were shown. Other scoring systems are hampered by a lack of validation or by their complexity that precludes routine clinical use. While the PULP score seems promising it needs external validation before widespread use.

  16. Comparing traditional and novel injury scoring systems in a US level-I trauma center: an opportunity for improved injury surveillance in low- and middle-income countries.

    PubMed

    Laytin, Adam D; Dicker, Rochelle A; Gerdin, Martin; Roy, Nobhojit; Sarang, Bhakti; Kumar, Vineet; Juillard, Catherine

    2017-07-01

    In most low- and middle-income countries (LMICs), the resources to accurately quantify injury severity using traditional injury scoring systems are limited. Novel injury scoring systems appear to have adequate discrimination for mortality in LMIC contexts, but they have not been rigorously compared where traditional injury scores can be accurately calculated. To determine whether novel injury scoring systems perform as well as traditional ones in a HIC with complete and comprehensive data collection. Data from an American level-I trauma registry collected 2008-2013 were used to compare three traditional injury scoring systems: Injury Severity Score (ISS); Revised Trauma Score (RTS); and Trauma Injury Severity Score (TRISS); and three novel injury scoring systems: Kampala Trauma Score (KTS); Mechanism, GCS, Age and Pressure (MGAP) score; and GCS, Age and Pressure (GAP) score. Logistic regression was used to assess the association between each scoring system and mortality. Standardized regression coefficients (β 2 ), Akaike information criteria, area under the receiver operating characteristics curve, and the calibration line intercept and slope were used to evaluate the discrimination and calibration of each model. Among 18,746 patients, all six scores were associated with hospital mortality. GAP had the highest effect size, and KTS had the lowest median Akaike information criteria. Although TRISS discriminated best, the discrimination of KTS approached that of TRISS and outperformed GAP, MGAP, RTS, and ISS. MGAP was best calibrated, and KTS was better calibrated than RTS, GAP, ISS, or TRISS. The novel injury scoring systems (KTS, MGAP, and GAP), which are more feasible to calculate in low-resource settings, discriminated hospital mortality as well as traditional injury scoring systems (ISS and RTS) and approached the discrimination of a sophisticated, data-intensive injury scoring system (TRISS) in a high-resource setting. Two novel injury scoring systems (KTS and MGAP) surpassed the calibration of TRISS. These novel injury scoring systems should be considered when clinicians and researchers wish to accurately account for injury severity. Implementation of these resource-appropriate tools in LMICs can improve injury surveillance, guiding quality improvement efforts, and supporting advocacy for resource allocation commensurate with the volume and severity of trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. ABCD2 score and BNP level in patients with TIA and cerebral stroke.

    PubMed

    Mortezabeigi, H R; Taghizadeh, A; Talebi, M; Amini, K; Goldust, M

    2013-11-01

    Scoring systems have been designed to help physicians in early prediction of cerebral stroke following Transitional Ischemic Attack (TIA). ABCD2 system is one of these scoring systems. Considering increase of brain natriuretic peptide following cerebral ischemic stroke, BNP level may be associated with incidence of ischemic stroke following TIA. The present study evaluates ABCD2 score, BNP level in patients with TIA and incidence of cerebral stroke. This cross sectional-analytical study evaluated 78 patients with TIA. ABCD2 score was calculated for all patients based on some criteria including age, blood pressure, clinical manifestations (speech/motor disorder), symptoms duration and diabetes. BNP level was measured at the reference laboratory when the patient referred to the treatment center. The patients were followed up for 6 months considering incidence of cerebral stroke and TIA. Mean age of the patients was 66.53 +/- 13.08 years and the sample was consisted of 62.8% male and 37.2% female patients. Mean BNP level and mean ABCD2 score was 611.31 +/- 125.61 and 4.61 +/- 10.99 in all patients, respectively. During follow-up period, TIA recurrence and cerebral stroke were, respectively seen in 11.5 and 3.8% of cases. Mortality was reported in 5.1% of the patients. BNP was significantly higher in cases with recursive TIA (p = 0.03). But, there was not any difference considering ABCD2 score (p = 0.38). BNP is capable of predicting TIA recurrence following first TIA and it can be used in this case.

  18. Automated detection and classification of dice

    NASA Astrophysics Data System (ADS)

    Correia, Bento A. B.; Silva, Jeronimo A.; Carvalho, Fernando D.; Guilherme, Rui; Rodrigues, Fernando C.; de Silva Ferreira, Antonio M.

    1995-03-01

    This paper describes a typical machine vision system in an unusual application, the automated visual inspection of a Casino's playing tables. The SORTE computer vision system was developed at INETI under a contract with the Portuguese Gaming Inspection Authorities IGJ. It aims to automate the tasks of detection and classification of the dice's scores on the playing tables of the game `Banca Francesa' (which means French Banking) in Casinos. The system is based on the on-line analysis of the images captured by a monochrome CCD camera placed over the playing tables, in order to extract relevant information concerning the score indicated by the dice. Image processing algorithms for real time automatic throwing detection and dice classification were developed and implemented.

  19. Integrating patient reported outcome measures and computerized adaptive test estimates on the same common metrics: an example from the assessment of activities in rheumatoid arthritis.

    PubMed

    Doğanay Erdoğan, Beyza; Elhan, Atilla Halİl; Kaskatı, Osman Tolga; Öztuna, Derya; Küçükdeveci, Ayşe Adile; Kutlay, Şehim; Tennant, Alan

    2017-10-01

    This study aimed to explore the potential of an inclusive and fully integrated measurement system for the Activities component of the International Classification of Functioning, Disability and Health (ICF), incorporating four classical scales, including the Health Assessment Questionnaire (HAQ), and a Computerized Adaptive Testing (CAT). Three hundred patients with rheumatoid arthritis (RA) answered relevant questions from four questionnaires. Rasch analysis was performed to create an item bank using this item pool. A further 100 RA patients were recruited for a CAT application. Both real and simulated CATs were applied and the agreement between these CAT-based scores and 'paper-pencil' scores was evaluated with intraclass correlation coefficient (ICC). Anchoring strategies were used to obtain a direct translation from the item bank common metric to the HAQ score. Mean age of 300 patients was 52.3 ± 11.7 years; disease duration was 11.3 ± 8.0 years; 74.7% were women. After testing for the assumptions of Rasch analysis, a 28-item Activities item bank was created. The agreement between CAT-based scores and paper-pencil scores were high (ICC = 0.993). Using those HAQ items in the item bank as anchoring items, another Rasch analysis was performed with HAQ-8 scores as separate items together with anchoring items. Finally a conversion table of the item bank common metric to the HAQ scores was created. A fully integrated and inclusive health assessment system, illustrating the Activities component of the ICF, was built to assess RA patients. Raw score to metric conversions and vice versa were available, giving access to the metric by a simple look-up table. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  20. Universality in the distance between two teams in a football tournament

    NASA Astrophysics Data System (ADS)

    da Silva, Roberto; Dahmen, Silvio R.

    2014-03-01

    Is football (soccer) a universal sport? Beyond the question of geographical distribution, where the answer is most certainly yes, when looked at from a mathematical viewpoint the scoring process during a match can be thought of, in a first approximation, as being modeled by a Poisson distribution. Recently, it was shown that the scoring of real tournaments can be reproduced by means of an agent-based model (da Silva et al. (2013) [24]) based on two simple hypotheses: (i) the ability of a team to win a match is given by the rate of a Poisson distribution that governs its scoring during a match; and (ii) such ability evolves over time according to results of previous matches. In this article we are interested in the question of whether the time series represented by the scores of teams have universal properties. For this purpose we define a distance between two teams as the square root of the sum of squares of the score differences between teams over all rounds in a double-round-robin-system and study how this distance evolves over time. Our results suggest a universal distance distribution of tournaments of different major leagues which is better characterized by an exponentially modified Gaussian (EMG). This result is corroborated by our agent-based model.

  1. A stage is a stage is a stage: a direct comparison of two scoring systems.

    PubMed

    Dawson, Theo L

    2003-09-01

    L. Kohlberg (1969) argued that his moral stages captured a developmental sequence specific to the moral domain. To explore that contention, the author compared stage assignments obtained with the Standard Issue Scoring System (A. Colby & L. Kohlberg, 1987a, 1987b) and those obtained with a generalized content-independent stage-scoring system called the Hierarchical Complexity Scoring System (T. L. Dawson, 2002a), on 637 moral judgment interviews (participants' ages ranged from 5 to 86 years). The correlation between stage scores produced with the 2 systems was .88. Although standard issue scoring and hierarchical complexity scoring often awarded different scores up to Kohlberg's Moral Stage 2/3, from his Moral Stage 3 onward, scores awarded with the two systems predominantly agreed. The author explores the implications for developmental research.

  2. Automated aortic calcium scoring on low-dose chest computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isgum, Ivana; Rutten, Annemarieke; Prokop, Mathias

    Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of themore » chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.« less

  3. Improvement of the Mair scoring system using structural equations modeling for classifying the diagnostic adequacy of cytology material from thyroid lesions.

    PubMed

    Kulkarni, H R; Kamal, M M; Arjune, D G

    1999-12-01

    The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.

  4. What Is the Relationship Between a Preclerkship Portfolio Review and Later Performance in Clerkships?

    PubMed

    O'Brien, Celia Laird; Thomas, John X; Green, Marianne M

    2018-01-01

    Medical educators struggle to find effective ways to assess essential competencies such as communication, professionalism, and teamwork. Portfolio-based assessment provides one method of addressing this problem by allowing faculty reviewers to judge performance, as based on a longitudinal record of student behavior. At the Feinberg School of Medicine, the portfolio system measures behavioral competence using multiple assessments collected over time. This study examines whether a preclerkship portfolio review is a valid method of identifying problematic student behavior affecting later performance in clerkships. The authors divided students into two groups based on a summative preclerkship portfolio review in 2014: students who had concerning behavior in one or more competencies and students progressing satisfactorily. They compared how students in these groups later performed on two clerkship outcomes as of October 2015: final grades in required clerkships, and performance on a clerkship clinical composite score. They used Mann-Whitney tests and multiple linear regression to examine the relationship between portfolio review results and clerkship outcomes. They used USMLE Step 1 to control for knowledge acquisition. Students with concerning behavior preclerkship received significantly lower clerkship grades than students progressing satisfactorily (P = .002). They also scored significantly lower on the clinical composite score (P < .001). Regression analysis indicated concerning behavior was associated with lower clinical composite scores, even after controlling for knowledge acquisition. The results show a preclerkship portfolio review can identify behaviors that impact clerkship performance. A comprehensive portfolio system is a valid way to measure behavioral competencies.

  5. Minefield reconnaissance and detector system

    DOEpatents

    Butler, M.T.; Cave, S.P.; Creager, J.D.; Johnson, C.M.; Mathes, J.B.; Smith, K.J.

    1994-04-26

    A multi-sensor system is described for detecting the presence of objects on the surface of the ground or buried just under the surface, such as anti-personnel or anti-tank mines or the like. A remote sensor platform has a plurality of metal detector sensors and a plurality of short pulse radar sensors. The remote sensor platform is remotely controlled from a processing and control unit and signals from the remote sensor platform are sent to the processing and control unit where they are individually evaluated in separate data analysis subprocess steps to obtain a probability score for each of the pluralities of sensors. These probability scores are combined in a fusion subprocess step by comparing score sets to a probability table which is derived based upon the historical incidence of object present conditions given that score set. A decision making rule is applied to provide an output which is optionally provided to a marker subprocess for controlling a marker device to mark the location of found objects. 7 figures.

  6. Chemical entity recognition in patents by combining dictionary-based and statistical approaches

    PubMed Central

    Akhondi, Saber A.; Pons, Ewoud; Afzal, Zubair; van Haagen, Herman; Becker, Benedikt F.H.; Hettne, Kristina M.; van Mulligen, Erik M.; Kors, Jan A.

    2016-01-01

    We describe the development of a chemical entity recognition system and its application in the CHEMDNER-patent track of BioCreative 2015. This community challenge includes a Chemical Entity Mention in Patents (CEMP) recognition task and a Chemical Passage Detection (CPD) classification task. We addressed both tasks by an ensemble system that combines a dictionary-based approach with a statistical one. For this purpose the performance of several lexical resources was assessed using Peregrine, our open-source indexing engine. We combined our dictionary-based results on the patent corpus with the results of tmChem, a chemical recognizer using a conditional random field classifier. To improve the performance of tmChem, we utilized three additional features, viz. part-of-speech tags, lemmas and word-vector clusters. When evaluated on the training data, our final system obtained an F-score of 85.21% for the CEMP task, and an accuracy of 91.53% for the CPD task. On the test set, the best system ranked sixth among 21 teams for CEMP with an F-score of 86.82%, and second among nine teams for CPD with an accuracy of 94.23%. The differences in performance between the best ensemble system and the statistical system separately were small. Database URL: http://biosemantics.org/chemdner-patents PMID:27141091

  7. Elbow-specific clinical rating systems: extent of established validity, reliability, and responsiveness.

    PubMed

    The, Bertram; Reininga, Inge H F; El Moumni, Mostafa; Eygendaal, Denise

    2013-10-01

    The modern standard of evaluating treatment results includes the use of rating systems. Elbow-specific rating systems are frequently used in studies aiming at elbow-specific pathology. However, proper validation studies seem to be relatively sparse. In addition, these scoring systems might not always be used for appropriate populations of interest. Both of these issues might give rise to invalid conclusions being reported in the literature. Our aim was to investigate the extent to which the available elbow-specific outcome measurement tools have been validated and the quality of the validation itself. We also aimed to provide characteristics of the populations used for validation of these scales to enable clinicians to use them appropriately. A literature search identified 17 studies of 12 different elbow-specific scoring systems. These were assessed for validity, reliability, and responsiveness characteristics. The quality of these assessments was rated according to the Consensus Based Standards for the Selection of Health Measurement Instruments (COSMIN) checklist criteria, a standardized and validated tool developed specifically for this purpose. Currently, the only elbow-specific rating system that is validated using high-quality methodology is the Oxford Elbow Score, a patient-administered outcome measure tool that has been validated on heterogeneous study populations. Other rating systems still have to be proven in the future to be as good as the Oxford Elbow Score for clinical or research purposes. Additional validation studies are needed. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  8. Understanding Building Infrastructure and Building Operation through DOE Asset Score Model: Lessons Learned from a Pilot Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Na; Goel, Supriya; Gorrissen, Willy J.

    2013-06-24

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system to help building owners to evaluate the as-built physical characteristics (including building envelope, the mechanical and electrical systems) and overall building energy efficiency, independent of occupancy and operational choices. The energy asset score breaks down building energy use information by simulating building performance under typical operating and occupancy conditions for a given use type. A web-based modeling tool, the energy asset score tool facilitates the implementation of the asset score system. The tool consists of a simplified user interface built on a centralized simulation enginemore » (EnergyPlus). It is intended to reduce both the implementation cost for the users and increase modeling standardization compared with an approach that requires users to build their own energy models. A pilot project with forty-two buildings (consisting mostly offices and schools) was conducted in 2012. This paper reports the findings. Participants were asked to collect a minimum set of building data and enter it into the asset score tool. Participants also provided their utility bills, existing ENERGY STAR scores, and previous energy audit/modeling results if available. The results from the asset score tool were compared with the building energy use data provided by the pilot participants. Three comparisons were performed. First, the actual building energy use, either from the utility bills or via ENERGY STAR Portfolio Manager, was compared with the modeled energy use. It was intended to examine how well the energy asset score represents a building’s system efficiencies, and how well it is correlated to a building’s actual energy consumption. Second, calibrated building energy models (where they exist) were used to examine any discrepancies between the asset score model and the pilot participant buildings’ [known] energy use pattern. This comparison examined the end use breakdowns and more detailed time series data. Third, ASHRAE 90.1 prototype buildings were also used as an industry standard modeling approach to test the accuracy level of the asset score tool. Our analysis showed that the asset score tool, which uses simplified building simulation, could provide results comparable to a more detailed energy model. The buildings’ as-built efficiency can be reflected in the energy asset score. An analysis between the modeled energy use through the asset score tool and the actual energy use from the utility bills can further inform building owners about the effectiveness of their building’s operation and maintenance.« less

  9. Physiological scoring: an aid to emergency medical services transport decisions?

    PubMed

    Challen, Kirsty; Walter, Darren

    2010-01-01

    Attendance at UK emergency departments is rising steadily despite the proliferation of alternative unscheduled care providers. Evidence is mixed on the willingness of emergency medical services (EMS) providers to decline to transport patients and the safety of incorporating such an option into EMS provision. Physiologically based Early Warning Scores are in use in many hospitals and emergency departments, but not yet have been proven to be of benefit in the prehospital arena. The use of a physiological-social scoring system could safely identify patients calling EMS who might be diverted from the emergency department to an alternative, unscheduled, care provider. This was a retrospective, cohort study of patients with a presenting complaint of "shortness of breath" or "difficulty breathing" transported to the emergency department by EMS. Retrospective calculation of a physiological social score (PMEWS) based on first recorded data from EMS records was performed. Outcome measures of hospital admission and need for physiologically stabilizing treatment in the emergency department also were performed. A total of 215 records were analyzed. One hundred thirty-nine (65%) patients were admitted from the emergency department or received physiologically stabilizing treatment in the emergency department. Area Under the Receiver Operating Characteristic Curve (AUROC) for hospital admission was 0.697 and for admission or physiologically stabilizing treatment was 0.710. No patient scoring<2 was admitted or received stabilizing treatment. Despite significant over-triage, this system could have diverted 79 patients safely from the emergency department to alternative, unscheduled, care providers.

  10. Power and Assessment: A Genealogical Analysis of the CLASS

    ERIC Educational Resources Information Center

    Gaches, Sonya; Hill, Diana

    2017-01-01

    The CLASS (classroom assessment scoring system) has become integrally linked with quality rating and improvement systems (QRIS) throughout the United States and other international locations. This relationship reinforces the neoliberal consumer-based perspectives of quality and devalues localized perspectives. This article challenges the notion of…

  11. Evaluation of the sustainability of contrasted pig farming systems: development of a market conformity tool for pork products based on technological quality traits.

    PubMed

    Gonzàlez, J; Gispert, M; Gil, M; Hviid, M; Dourmad, J Y; de Greef, K H; Zimmer, C; Fàbrega, E

    2014-12-01

    A market conformity tool, based on technological meat quality parameters, was developed within the Q-PorkChains project, to be included in a global sustainability evaluation of pig farming systems. The specific objective of the market conformity tool was to define a scoring system based on the suitability of meat to elaborate the main pork products, according to their market shares based on industry requirements, in different pig farming systems. The tool was based on carcass and meat quality parameters that are commonly used for the assessment of technological quality, which provide representative and repeatable data and are easily measurable. They were the following: cold carcass weight; lean meat percentage; minimum subcutaneous back fat depth at m. gluteus medius level, 45 postmortem and ultimate pH (measured at 24-h postmortem) in m. longissimus lumborum and semimembranosus; meat colour; drip losses and intramuscular fat content in a m. longissimus sample. Five categories of pork products produced at large scale in Europe were considered in the study: fresh meat, cooked products, dry products, specialties and other meat products. For each of the studied farming systems, the technological meat quality requirements, as well as the market shares for each product category within farming system, were obtained from the literature and personal communications from experts. The tool resulted in an overall conformity score that enabled to discriminate among systems according to the degree of matching of the achieved carcass and meat quality with the requirements of the targeted market. In order to improve feasibility, the tool was simplified by selecting ultimate pH at m. longissimus or semimembranosus, minimum fat thickness measured at the left half carcass over m. gluteus medius and intramuscular fat content in a m. longissimus sample as iceberg indicators. The overall suitability scores calculated by using both the complete and the reduced tools presented good correlation and the results obtained were similar. The tool could be considered as robust enough to discriminate among different systems, since it was tested in a wide range of them. It also can be used to detect improvement opportunities to enhance sustainability of pig farming systems. The final objective of the study was achieved, since the market suitability tool could be used in an integrated sustainability analysis of pig farming systems.

  12. [Modified McPeek score in multiple trauma patients. Prospective evaluation of a points system for recording follow-up factors].

    PubMed

    Mathis, S; Kellermann, S; Schmid, S; Mutschlechner, H; Raab, H; Wenzel, V; El Attal, R; Kreutziger, J

    2014-05-01

    Many commonly available trauma scores predict mortality, but to evaluate the success of a certain therapy or for difficult scientific and epidemiological purposes this may be insufficient in the face of improved survival rates. For outcome analysis of multiple trauma patients, the extent of medical resources needed could be an additional outcome measurement. McPeek et al. developed a potential scoring system for elective surgery patients, which was recently modified for multiple trauma patients. The current study investigated if the McPeek score could be prospectively used in multiple trauma patients and whether it could become an additional helpful tool in outcome assessment. Applicability was assessed by practical examples. In this prospective single-centre study at the University Hospital of Innsbruck, Austria, between December 2008 and November 2010 multiple trauma patients (≥ 18 years) with an injury severity score (ISS) ≥ 17 were enrolled. Besides demographic data, prehospital vital parameters and diagnoses, all diagnoses from the trauma, mortality, length of stay in the intensive care unit and the hospital were recorded. The commonly used trauma scores ISS, revised trauma score (RTS), a severity characterization of trauma (ASCOT) and trauma and injury severity score (TRISS) were applied and an observed McPeek score was allocated following end of hospitalization. The McPeek scoring system was used according to the latest modifications. A correlation between trauma scores and the McPeek score was performed. The McPeek score was then predicted by a common trauma score using ordinal regression with the polytomous universal model (PLUM method). By subtracting the predicted from the observed McPeek scores the residual McPeek value was calculated and used for practical examples of outcome analysis with the McPeek scoring system. Out of 406 identified multiple trauma patients during the study phase, 183 had to be excluded due to missing data (mainly prehospital or following transfer). A total of 223 patients (mean ISS 31.2, mean age 47.2 years) were enrolled and assigned to the population-based observed McPeek score (median 4.0). Correlation coefficients were Glasgow coma scale (GCS) 0.59, ISS 0.62, RTS 0.65, TRISS 0.74 and ASCOT 0.77 (p < 0.0001). The TRISS predicted the McPeek score best in ordinal regression (pseudo-R(2) = 0.944, p < 0.0001). The residual McPeek score (observed minus predicted) was used to illustrate the influence of the blood glucose level on admission and the influence of head injury on outcome of multiple injury patients in detail. The modified McPeek score is applicable to multiple trauma patients to assess outcome for scientific or epidemiological purposes. Its main advantage is that it quantifies outcome independently of regional or national circumstances.

  13. A retrospective review of required projects in systems-based practice in a single anesthesiology residency: a 10-year experience.

    PubMed

    Sakai, Tetsuro; Emerick, Trent D; Patel, Rita M

    2015-09-01

    The Accreditation Council for Graduate Medical Education has emphasized in its core competencies and more recently, in its Milestones Project, that residents understand the importance of systems-based practice (SBP). The objectives of the study are to evaluate the quality of residents' SBP projects and to determine the degrees that were subsequently implemented. A retrospective educational observational study. A university-based anesthesiology training institution. One hundred forty-nine anesthesiology residents in their final (postgraduate year 4) year of training who completed SBP projects for the last 10 years (2004-2013). A structured SBP course was provided for postgraduate year 4 anesthesiology residents with deadlines set such as project identification, data collection, and proposal draft. Each resident's written SBP proposal received inputs by 2 members of the department executive steering committee. The SBP projects concluded with oral presentations by each resident to the department executive steering committee, who provided overall scores. All SBP projects were categorized into 7 categories: safety initiatives, economic analysis, process analysis, policy change recommendations, education initiatives, teamwork/communication, and operating room efficiency. Evaluation scores using a Likert scale (1-9, where 9 is the best) were analyzed. The rate of implementation of project ideas within the department based on the presentations to the executive committee was examined. Of 149 projects, policy change recommendations was the most frequently chosen category (46 projects; 30.9%), followed by process analysis (36 projects; 24.2%). The overall evaluation score was 7.6 ± 0.6 (mean ± SD). A total of 53 projects (35.6%) were implemented in the department. There was no statistical difference between SBPs with implementation vs SBPs without implementation in terms of evaluation scores, year of the presentation, or categories. This SBP project has given residents the opportunity to participate in a hospital system change aiming to improve efficiency and safety. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Prognostic Value of AIMS65 Score in Cirrhotic Patients with Upper Gastrointestinal Bleeding.

    PubMed

    Gaduputi, Vinaya; Abdulsamad, Molham; Tariq, Hassan; Rafeeq, Ahmed; Abbas, Naeem; Kumbum, Kavitha; Chilimuri, Sridhar

    2014-01-01

    Introduction. Unlike Rockall scoring system, AIMS65 is based only on clinical and laboratory features. In this study we investigated the correlation between the AIMS65 score and Endoscopic Rockall score, in cirrhotic and noncirrhotic patients. Methods. This is a retrospective study of patients admitted with overt UGIB and undergoing esophagogastroduodenoscopy (EGD). AIMS65 and Rockall scores were calculated at the time of admission. We investigated the correlation between both scores along with stigmata of bleed seen on endoscopy. Results. A total of 1255 patients were studied. 152 patients were cirrhotic while 1103 patients were noncirrhotic. There was significant correlation between AIMS65 and Total Rockall scores in patients of both groups. There was significant correlation between AIMS65 score and Endoscopic Rockall score in noncirrhotics but not cirrhotics. AIMS65 scores in both cirrhotic and noncirrhotic groups were significantly higher in patients who died from UGIB than in patients who did not. Conclusion. We observed statistically significant correlation between AIMS65 score and length of hospitalization and mortality in noncirrhotic patients. We found that AIMS65 score paralleled the endoscopic grading of lesion causing UGIB in noncirrhotics. AIMS65 score correlated only with mortality but not the length of hospitalization or endoscopic stigmata of bleed in cirrhotics.

  15. District health information system assessment: a case study in iran.

    PubMed

    Raeisi, Ahmad Reza; Saghaeiannejad, Sakineh; Karimi, Saeed; Ehteshami, Asghar; Kasaei, Mahtab

    2013-03-01

    Health care managers and personnel should be aware and literate of health information system in order to increase the efficiency and effectiveness in their organization. Since accurate, appropriate, precise, timely, valid information and interpretation of information is required and is the basis for policy planning and decision making in various levels of the organization. This study was conducted to assess the district health information system evolution in Iran according to WHO framework. This research is an applied, descriptive cross sectional study, in which a total of twelve urban and eight rural facilities, and the district health center at Falavarjan region were surveyed by using a questionnaire with 334 items. Content and constructive validity and reliability of the questionnaire were confirmed with correlation coefficient of 0.99. Obtained data were analyzed with SPSS 16 software and descriptive statistics were used to examine measures of WHO compliance. The analysis of data revealed that the mean score of compliance of district health information system framework was 35.75 percent. The maximum score of compliance with district health information system belonged to the data collection process (70 percent). The minimum score of compliance with district health information system belonged to information based decision making process with a score of 10 percent. District Health Information System Criteria in Isfahan province do not completely comply with WHO framework. Consequently, it seems that health system managers engaged with underlying policy and decision making processes at district health level should try to restructure and decentralize district health information system and develop training management programs for their managers.

  16. LANDMARK-BASED SPEECH RECOGNITION: REPORT OF THE 2004 JOHNS HOPKINS SUMMER WORKSHOP.

    PubMed

    Hasegawa-Johnson, Mark; Baker, James; Borys, Sarah; Chen, Ken; Coogan, Emily; Greenberg, Steven; Juneja, Amit; Kirchhoff, Katrin; Livescu, Karen; Mohan, Srividya; Muller, Jennifer; Sonmez, Kemal; Wang, Tianyu

    2005-01-01

    Three research prototype speech recognition systems are described, all of which use recently developed methods from artificial intelligence (specifically support vector machines, dynamic Bayesian networks, and maximum entropy classification) in order to implement, in the form of an automatic speech recognizer, current theories of human speech perception and phonology (specifically landmark-based speech perception, nonlinear phonology, and articulatory phonology). All three systems begin with a high-dimensional multiframe acoustic-to-distinctive feature transformation, implemented using support vector machines trained to detect and classify acoustic phonetic landmarks. Distinctive feature probabilities estimated by the support vector machines are then integrated using one of three pronunciation models: a dynamic programming algorithm that assumes canonical pronunciation of each word, a dynamic Bayesian network implementation of articulatory phonology, or a discriminative pronunciation model trained using the methods of maximum entropy classification. Log probability scores computed by these models are then combined, using log-linear combination, with other word scores available in the lattice output of a first-pass recognizer, and the resulting combination score is used to compute a second-pass speech recognition output.

  17. New integrated information system for pusan national university hospital.

    PubMed

    Kim, Hyung Hoi; Cho, Kyung-Won; Kim, Hye Sook; Kim, Ju-Sim; Kim, Jung Hyun; Han, Sang Pil; Park, Chun Bok; Kim, Seok; Chae, Young Moon

    2011-03-01

    This study presents the information system for Pusan National University Hospital (PNUH), evaluates its performance qualitatively, and conducts economic analysis. Information system for PNUH was designed by component-based development and developed by internet technologies. Order Communication System, Electronic Medical Record, and Clinical Decision Support System were newly developed. The performance of the hospital information system was qualitatively evaluated based on the performance reference model in order to identify problem areas for the old system. The Information Economics approach was used to analyze the economic feasibility of hospital information system in order to account for the intangible benefits. Average performance scores were 3.16 for input layer, 3.35 for process layer, and 3.57 for business layer. In addition, the cumulative benefit to cost ratio was 0.50 in 2011, 1.73 in 2012, 1.76 in 2013, 1.71 in 2014, and 1.71 in 2015. The B/C ratios steadily increase as value items are added. While overall performance scores were reasonably high, doctors were less satisfied with the system, perhaps due to the weak clinical function in the systems. The information economics analysis demonstrated the economic profitability of the information systems if all intangible benefits were included. The second qualitative evaluation survey and economic analysis were proposed to evaluate the changes in performance of the new system.

  18. Validity and reliability of a novel immunosuppressive adverse effects scoring system in renal transplant recipients.

    PubMed

    Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M

    2014-06-12

    After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse effects (p=0.008) in renal transplant recipients receiving tacrolimus and mycophenolic acid compared to the cyclosporine regimen. This finding demonstrated construct validity. Intra-class correlation was 0.81 (95% confidence interval: 0.65-0.90) and Kappa statistic of 0.68 ± 0.25 for all 18 adverse effects and verified substantial inter-rater reliability. This immunosuppressive adverse effects scoring system in stable renal transplant recipients was evaluated and substantiated face, content and construct validity with inter-rater reliability. The scoring system may facilitate prospective, standardized clinical monitoring of immunosuppressive adverse drug effects in stable renal transplant recipients and improve medication adherence.

  19. A preliminary score for the assessment of disease activity in hereditary recurrent fevers: results from the AIDAI (Auto-Inflammatory Diseases Activity Index) Consensus Conference

    PubMed Central

    Piram, Maryam; Frenkel, Joost; Gattorno, Marco; Ozen, Seza; Lachmann, Helen J; Goldbach-Mansky, Raphaela; Hentgen, Véronique; Neven, Bénédicte; Stankovic Stojanovic, Katia; Simon, Anna; Kuemmerle-Deschner, Jasmin; Hoffman, Hal; Stojanov, Silvia; Duquesne, Agnès; Pillet, Pascal; Martini, Alberto; Pouchot, Jacques; Koné-Paut, Isabelle

    2012-01-01

    Background The systemic autoinflammatory disorders (SAID) share many clinical manifestations, albeit with variable patterns, intensity and frequency. A common definition of disease activity would be rational and useful in the management of these lifelong diseases. Moreover, standardised disease activity scores are required for the assessment of new therapies in constant development. The aim of this study was to develop preliminary activity scores for familial Mediterranean fever, mevalonate kinase deficiency, tumour necrosis factor receptor-1-associated periodic syndrome and cryopyrin-associated periodic syndromes (CAPS). Methods The study was conducted using two well-recognised consensus formation methods: the Delphi technique and the nominal group technique. The results from a two-step survey and data from parent/patient interviews were used as preliminary data to develop the agenda for a consensus conference to build a provisional scoring system. Results 24 of 65 experts in SAID from 20 countries answered the web questionnaire and 16 attended the consensus conference. There was consensus agreement to develop separate activity scores for each disease but with a common format based on patient diaries. Fever and disease-specific clinical variables were scored according to their severity. A final score was generated by summing the score of all the variables divided by the number of days over which the diary was completed. Scores varied from 0 to 16 (0–13 in CAPS). These scores were developed for the purpose of clinical studies but could be used in clinical practice. Conclusion Using widely recognised consensus formation techniques, preliminary scores were obtained to measure disease activity in four main SAID. Further prospective validation study of this instrument will follow. PMID:21081528

  20. Preliminary validation of the Knee Inflammation MRI Scoring System (KIMRISS) for grading bone marrow lesions in osteoarthritis of the knee: data from the Osteoarthritis Initiative

    PubMed Central

    Jeffery, Dean; Buller, M; Wichuk, Stephanie; McDougall, Dave; Lambert, Robert GW; Maksymowych, Walter P

    2017-01-01

    Objective Bone marrow lesions (BML) are an MRI feature of osteoarthritis (OA) offering a potential target for therapy. We developed the Knee Inflammation MRI Scoring System (KIMRISS) to semiquantitatively score BML with high sensitivity to small changes, and compared feasibility, reliability and responsiveness versus the established MRI Osteoarthritis Knee Score (MOAKS). Methods KIMRISS incorporates a web-based graphic overlay to facilitate detailed regional BML scoring. Observers scored BML by MOAKS and KIMRISS on sagittal fluid-sensitive sequences. Exercise 1 focused on interobserver reliability in Osteoarthritis Initiative observational data, with 4 readers (two experienced/two new to KIMRISS) scoring BML in 80 patients (baseline/1 year). Exercise 2 focused on responsiveness in an open-label trial of adalimumab, with 2 experienced readers scoring BML in 16 patients (baseline/12 weeks). Results Scoring time was similar for KIMRISS and MOAKS. Interobserver reliability of KIMRISS was equivalent to MOAKS for BML status (ICC=0.84 vs 0.79), but consistently better than MOAKS for change in BML: Exercise 1 (ICC 0.82 vs 0.53), Exercise 2 (ICC 0.90 vs 0.32), and in new readers (0.87–0.92 vs 0.32–0.51). KIMRISS BML was more responsive than MOAKS BML: post-treatment BML improvement in Exercise 2 reached statistical significance for KIMRISS (SRM −0.69, p=0.015), but not MOAKS (SRM −0.12, p=0.625). KIMRISS BML also more strongly correlated to WOMAC scores than MOAKS BML (r=0.80 vs 0.58, p<0.05). Conclusions KIMRISS BML scoring was highly feasible, and was more reliable for assessment of change and more responsive to change than MOAKS BML for expert and new readers. PMID:28123780

  1. Long-term morbidity, mortality, and economics of rheumatoid arthritis.

    PubMed

    Wong, J B; Ramey, D R; Singh, G

    2001-12-01

    To estimate the morbidity, mortality, and lifetime costs of care for rheumatoid arthritis (RA). We developed a Markov model based on the Arthritis, Rheumatism, and Aging Medical Information System Post-Marketing Surveillance Program cohort, involving 4,258 consecutively enrolled RA patients who were followed up for 17,085 patient-years. Markov states of health were based on drug treatment and Health Assessment Questionnaire scores. Costs were based on resource utilization, and utilities were based on visual analog scale-based general health scores. The cohort had a mean age of 57 years, 76.4% were women, and the mean duration of disease was 11.8 years. Compared with a life expectancy of 22.0 years for the general population, this cohort had a life expectancy of 18.6 years and 11.3 quality-adjusted life years. Lifetime direct medical care costs were estimated to be $93,296. Higher costs were associated with higher disability scores. A Markov model can be used to estimate lifelong morbidity, mortality, and costs associated with RA, providing a context in which to consider the potential value of new therapies for the disease.

  2. Development and validation of a surgical-pathologic staging and scoring system for cervical cancer.

    PubMed

    Li, Shuang; Li, Xiong; Zhang, Yuan; Zhou, Hang; Tang, Fangxu; Jia, Yao; Hu, Ting; Sun, Haiying; Yang, Ru; Chen, Yile; Cheng, Xiaodong; Lv, Weiguo; Wu, Li; Zhou, Jin; Wang, Shaoshuai; Huang, Kecheng; Wang, Lin; Yao, Yuan; Yang, Qifeng; Yang, Xingsheng; Zhang, Qinghua; Han, Xiaobing; Lin, Zhongqiu; Xing, Hui; Qu, Pengpeng; Cai, Hongbing; Song, Xiaojie; Tian, Xiaoyu; Shen, Jian; Xi, Ling; Li, Kezhen; Deng, Dongrui; Wang, Hui; Wang, Changyu; Wu, Mingfu; Zhu, Tao; Chen, Gang; Gao, Qinglei; Wang, Shixuan; Hu, Junbo; Kong, Beihua; Xie, Xing; Ma, Ding

    2016-04-12

    Most cervical cancer patients worldwide receive surgical treatments, and yet the current International Federation of Gynecology and Obstetrics (FIGO) staging system do not consider surgical-pathologic data. We propose a more comprehensive and prognostically valuable surgical-pathologic staging and scoring system (SPSs). Records from 4,220 eligible cervical cancer cases (Cohort 1) were screened for surgical-pathologic risk factors. We constructed a surgical-pathologic staging and SPSs, which was subsequently validated in a prospective study of 1,104 cervical cancer patients (Cohort 2). In Cohort 1, seven independent risk factors were associated with patient outcome: lymph node metastasis (LNM), parametrial involvement, histological type, grade, tumor size, stromal invasion, and lymph-vascular space invasion (LVSI). The FIGO staging system was revised and expanded into a surgical-pathologic staging system by including additional criteria of LNM, stromal invasion, and LVSI. LNM was subdivided into three categories based on number and location of metastases. Inclusion of all seven prognostic risk factors improves practical applicability. Patients were stratified into three SPSs risk categories: zero-, low-, and high-score with scores of 0, 1 to 3, and ≥4 (P=1.08E-45; P=6.15E-55). In Cohort 2, 5-year overall survival (OS) and disease-free survival (DFS) outcomes decreased with increased SPSs scores (P=9.04E-15; P=3.23E-16), validating the approach. Surgical-pathologic staging and SPSs show greater homogeneity and discriminatory utility than FIGO staging. Surgical-pathologic staging and SPSs improve characterization of tumor severity and disease invasion, which may more accurately predict outcome and guide postoperative therapy.

  3. Non-localization and localization ROC analyses using clinically based scoring

    NASA Astrophysics Data System (ADS)

    Paquerault, Sophie; Samuelson, Frank W.; Myers, Kyle J.; Smith, Robert C.

    2009-02-01

    We are investigating the potential for differences in study conclusions when assessing the estimated impact of a computer-aided detection (CAD) system on readers' performance. The data utilized in this investigation were derived from a multi-reader multi-case observer study involving one hundred mammographic background images to which fixed-size and fixed-intensity Gaussian signals were added, generating a low- and high-intensity signal sets. The study setting allowed CAD assessment in two situations: when CAD sensitivity was 1) superior or 2) lower than the average reader. Seven readers were asked to review each set in the unaided and CAD-aided reading modes, mark and rate their findings. Using this data, we studied the effect on study conclusion of three clinically-based receiver operating characteristic (ROC) scoring definitions. These scoring definitions included both location-specific and non-location-specific rules. The results showed agreement in the estimated impact of CAD on the overall reader performance. In the study setting where CAD sensitivity is superior to the average reader, the mean difference in AUC between the CAD-aided read and unaided read was 0.049 (95%CIs: -0.027; 0.130) for the image scoring definition that is based on non-location-specific rules, and 0.104 (95%CIs: 0.036; 0.174) and 0.090 (95%CIs: 0.031; 0.155) for image scoring definitions that are based on location-specific rules. The increases in AUC were statistically significant for the location-specific scoring definitions. It was further observed that the variance on these estimates was reduced when using the location-specific scoring definitions compared to that using a non-location-specific scoring definition. In the study setting where CAD sensitivity is equivalent or lower than the average reader, the mean differences in AUC are slightly above 0.01 for all image scoring definitions. These increases in AUC were not statistical significant for any of the image scoring definitions. The results on the variance analysis differed from those observed in the other study setting. This investigation furthers our understanding of the relationships between non-localization-specific and localization-specific ROC assessment methodologies and their relevance to clinical practice.

  4. A Comparison of Diarrheal Severity Scores in the MAL-ED Multisite Community-Based Cohort Study

    PubMed Central

    Lee, Gwenyth O.; Richard, Stephanie A.; Kang, Gagandeep; Houpt, Eric R.; Seidman, Jessica C.; Pendergast, Laura L.; Bhutta, Zulfiqar A.; Ahmed, Tahmeed; Mduma, Estomih R.; Lima, Aldo A.; Bessong, Pascal; Jennifer, Mats Steffi; Hossain, Md. Iqbal; Chandyo, Ram Krishna; Nyathi, Emanuel; Lima, Ila F.; Pascal, John; Soofi, Sajid; Ladaporn, Bodhidatta; Guerrant, Richard L.; Caulfield, Laura E.; Black, Robert E.; Kosek, Margaret N.

    2016-01-01

    ABSTRACT Objectives: There is a lack of consensus on how to measure diarrheal severity. Within the context of a multisite, prospective cohort study, we evaluated the performance of a modified Vesikari score (MAL-ED), 2 previously published scores (Clark and CODA [a diarrheal severity score (Community DiarrheA) published by Lee et al]), and a modified definition of moderate-to-severe diarrhea (MSD) based on dysentery and health care worker diagnosed dehydration. Methods: Scores were built using maternally reported symptoms or fieldworker-reported clinical signs obtained during the first 7 days of a diarrheal episode. The association between these and the risk of hospitalization were tested using receiver operating characteristic analysis. Severity scores were also related to illness etiology, and the likelihood of the episode subsequently becoming prolonged or persistent. Results: Of 10,159 episodes from 1681 children, 143 (4.0%) resulted in hospitalization. The area under the curve of each score as a predictor of hospitalization was 0.84 (95% confidence interval: 0.81, 0.87) (Clark), 0.85 (0.82, 0.88) (MAL-ED), and 0.87 (0.84, 0.89) (CODA). Severity was also associated with etiology and episode duration. Although families were more likely to seek care for severe diarrhea, approximately half of severe cases never reached the health system. Conclusions: Community-based diarrheal severity scores are predictive of relevant child health outcomes. Because they require no assumptions about health care access or utilization, they are useful in refining estimates of the burden of diarrheal disease, in estimating the effect of disease control interventions, and in triaging children for referral in low- and middle-income countries in which the rates of morbidity and mortality after diarrhea remain high. PMID:27347723

  5. Resistance to intravenous immunoglobulin in children with Kawasaki disease

    PubMed Central

    Tremoulet, Adriana H.; Best, Brookie M.; Song, Sungchan; Wang, Susan; Corinaldesi, Elena; Eichenfield, Julia R.; Martin, Danielle D.; Newburger, Jane W.; Burns, Jane C.

    2008-01-01

    Objectives To explore the increased incidence of intravenous immunoglobulin (IVIG) resistance among San Diego County Kawasaki disease (KD) patients in 2006 and to evaluate a scoring system to predict IVIG-resistant patients with KD. Study design We performed a retrospective review of patients with KD treated within 10 days of fever onset. Using multivariate analysis, independent predictors of IVIG-resistance were combined into a scoring system. Results In 2006, 38.3 % of patients with KD in San Diego County were IVIG-resistant, a significant increase over previous years. IVIG-resistance was not associated with a particular brand or lot of IVIG. Resistant patients were diagnosed earlier, had higher % bands, and higher concentrations of C-reactive protein, alanine aminotransferase, and γ-glutamyl transferase (GGT). They also had lower platelet counts and age-adjusted hemoglobin (zHgb) concentrations and were more likely to have aneurysms (p=0.0008). A scoring system developed to predict IVIG-resistant patients using illness day, % bands, GGT, and zHgb, had a sensitivity of 73.3% and specificity of 61.9%. Conclusions An unexplained increase in IVIG-resistance was noted among patients with KD in San Diego County in 2006. Scoring systems based on demographic and laboratory data were insufficiently accurate to be clinically useful in our ethnically diverse population. PMID:18571548

  6. Effect of omega-3 fatty acids on canine atopic dermatitis.

    PubMed

    Mueller, R S; Fieseler, K V; Fettman, M J; Zabel, S; Rosychuk, R A W; Ogilvie, G K; Greenwalt, T L

    2004-06-01

    Twenty-nine dogs were included in a double-blinded, placebo-controlled, randomised trial and were orally supplemented for 10 weeks with either flax oil (200 mg/kg/day), eicosapentaenoic acid (50 mg/kg/day) and docosahexaenoic acid (35 mg/kg/day) in a commercial preparation, or mineral oil as a placebo. For each dog, clinical scores were determined based on a scoring system developed prior to the trial. Total omega-6 and omega-3 intake and the ratio of omega-6:omega-3 (omega-6:3) were calculated before and after the trial. The dogs' clinical scores improved in those supplemented with flax oil and the commercial preparation, but not in the placebo group. No correlation was identified between total fatty acid intake or omega-6:3 ratio and clinical scores. Based on the results of this study, the total intake of fatty acids or the omega-6:3 ratio do not seem to be the main factors in determining the clinical response.

  7. Comparing the Scoring of Human Decomposition from Digital Images to Scoring Using On-site Observations.

    PubMed

    Dabbs, Gretchen R; Bytheway, Joan A; Connor, Melissa

    2017-09-01

    When in forensic casework or empirical research in-person assessment of human decomposition is not possible, the sensible substitution is color photographic images. To date, no research has confirmed the utility of color photographic images as a proxy for in situ observation of the level of decomposition. Sixteen observers scored photographs of 13 human cadavers in varying decomposition stages (PMI 2-186 days) using the Total Body Score system (total n = 929 observations). The on-site TBS was compared with recorded observations from digital color images using a paired samples t-test. The average difference between on-site and photographic observations was -0.20 (t = -1.679, df = 928, p = 0.094). Individually, only two observers, both students with <1 year of experience, demonstrated TBS statistically significantly different than the on-site value, suggesting that with experience, observations of human decomposition based on digital images can be substituted for assessments based on observation of the corpse in situ, when necessary. © 2017 American Academy of Forensic Sciences.

  8. Hierarchically Structured Recommender System for Improving NPS

    ERIC Educational Resources Information Center

    Kuang, Jieyan

    2016-01-01

    Net Promoter System (NPS) is well known as an evaluation measure of the growth engine of big companies in the business area. The ultimate goal of my research is to build an action rules and meta-actions based recommender system for improving NPS scores of 34 companies (clients) dealing with similar businesses in the US and Canada. With the given…

  9. Preliminary report of the Hepatic Encephalopathy Assessment Driving Simulator (HEADS) score.

    PubMed

    Baskin-Bey, Edwina S; Stewart, Charmaine A; Mitchell, Mary M; Bida, John P; Rosenthal, Theodore J; Nyberg, Scott L

    2008-01-01

    Audiovisual simulations of real-life driving (ie, driving simulators) have been used to assess neurologic dysfunction in a variety of medical applications. However, the use of simulated driving to assess neurologic impairment in the setting of liver disease (ie, hepatic encephalopathy) is limited. The aim of this analysis was to develop a scoring system based on simulated driving performance to assess mild cognitive impairment in cirrhotic patients with hepatic encephalopathy. This preliminary analysis was conducted as part of the Hepatic Encephalopathy Assessment Driving Simulator (HEADS) pilot study. Cirrhotic volunteers initially underwent a battery of neuropsychological tests to identify those cirrhotic patients with mild cognitive impairment. Performance during an audiovisually simulated course of on-road driving was then compared between mildly impaired cirrhotic patients and healthy volunteers. A scoring system was developed to quantify the likelihood of cognitive impairment on the basis of data from the simulated on-road driving. Mildly impaired cirrhotic patients performed below the level of healthy volunteers on the driving simulator. Univariate logistic regression and correlation models indicated that several driving simulator variables were significant predictors of cognitive impairment. Five variables (run time, total map performance, number of collisions, visual divided attention response, and average lane position) were incorporated into a quantitative model, the HEADS scoring system. The HEADS score (0-9 points) showed a strong correlation with cognitive impairment as measured by area under the receiver-operator curve (.89). The HEADS system appears to be a promising new tool for the assessment of mild hepatic encephalopathy.

  10. Multiparametric and semiquantitative scoring systems for the evaluation of mouse model histopathology - a systematic review

    PubMed Central

    2013-01-01

    Background Histopathology has initially been and is still used to diagnose infectious, degenerative or neoplastic diseases in humans or animals. In addition to qualitative diagnoses semiquantitative scoring of a lesion`s magnitude on an ordinal scale is a commonly demanded task for histopathologists. Multiparametric, semiquantitative scoring systems for mouse models histopathology are a common approach to handle these questions and to include histopathologic information in biomedical research. Results Inclusion criteria for scoring systems were a first description of a multiparametric, semiquantiative scoring systems which comprehensibly describe an approach to evaluate morphologic lesion. A comprehensive literature search using these criteria identified 153 originally designed semiquantitative scoring systems for the analysis of morphologic changes in mouse models covering almost all organs systems and a wide variety of disease models. Of these, colitis, experimental autoimmune encephalitis, lupus nephritis and collagen induced osteoarthritis colitis were the disease models with the largest number of different scoring systems. Closer analysis of the identified scoring systems revealed a lack of a rationale for the selection of the scoring parameters or a correlation between scoring parameter value and the magnitude of the clinical symptoms in most studies. Conclusion Although a decision for a particular scoring system is clearly dependent on the respective scientific question this review gives an overview on currently available systems and may therefore allow for a better choice for the respective project. PMID:23800279

  11. Size-adjusted Quantitative Gleason Score as a Predictor of Biochemical Recurrence after Radical Prostatectomy.

    PubMed

    Deng, Fang-Ming; Donin, Nicholas M; Pe Benito, Ruth; Melamed, Jonathan; Le Nobin, Julien; Zhou, Ming; Ma, Sisi; Wang, Jinhua; Lepor, Herbert

    2016-08-01

    The risk of biochemical recurrence (BCR) following radical prostatectomy for pathologic Gleason 7 prostate cancer varies according to the proportion of Gleason 4 component. We sought to explore the value of several novel quantitative metrics of Gleason 4 disease for the prediction of BCR in men with Gleason 7 disease. We analyzed a cohort of 2630 radical prostatectomy cases from 1990-2007. All pathologic Gleason 7 cases were identified and assessed for quantity of Gleason pattern 4. Three methods were used to quantify the extent of Gleason 4: a quantitative Gleason score (qGS) based on the proportion of tumor composed of Gleason pattern 4, a size-weighted score (swGS) incorporating the overall quantity of Gleason 4, and a size index (siGS) incorporating the quantity of Gleason 4 based on the index lesion. Associations between the above metrics and BCR were evaluated using Cox proportional hazards regression analysis. qGS, swGS, and siGS were significantly associated with BCR on multivariate analysis when adjusted for traditional Gleason score, age, prostate specific antigen, surgical margin, and stage. Using Harrell's c-index to compare the scoring systems, qGS (0.83), swGS (0.84), and siGS (0.84) all performed better than the traditional Gleason score (0.82). Quantitative measures of Gleason pattern 4 predict BCR better than the traditional Gleason score. In men with Gleason 7 prostate cancer, quantitative analysis of the proportion of Gleason pattern 4 (quantitative Gleason score), as well as size-weighted measurement of Gleason 4 (size-weighted Gleason score), and a size-weighted measurement of Gleason 4 based on the largest tumor nodule significantly improve the predicted risk of biochemical recurrence compared with the traditional Gleason score. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Risk score for first-screening of prevalent undiagnosed chronic kidney disease in Peru: the CRONICAS-CKD risk score.

    PubMed

    Carrillo-Larco, Rodrigo M; Miranda, J Jaime; Gilman, Robert H; Medina-Lezama, Josefina; Chirinos-Pacheco, Julio A; Muñoz-Retamozo, Paola V; Smeeth, Liam; Checkley, William; Bernabe-Ortiz, Antonio

    2017-11-29

    Chronic Kidney Disease (CKD) represents a great burden for the patient and the health system, particularly if diagnosed at late stages. Consequently, tools to identify patients at high risk of having CKD are needed, particularly in limited-resources settings where laboratory facilities are scarce. This study aimed to develop a risk score for prevalent undiagnosed CKD using data from four settings in Peru: a complete risk score including all associated risk factors and another excluding laboratory-based variables. Cross-sectional study. We used two population-based studies: one for developing and internal validation (CRONICAS), and another (PREVENCION) for external validation. Risk factors included clinical- and laboratory-based variables, among others: sex, age, hypertension and obesity; and lipid profile, anemia and glucose metabolism. The outcome was undiagnosed CKD: eGFR < 60 ml/min/1.73m 2 . We tested the performance of the risk scores using the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, positive/negative predictive values and positive/negative likelihood ratios. Participants in both studies averaged 57.7 years old, and over 50% were females. Age, hypertension and anemia were strongly associated with undiagnosed CKD. In the external validation, at a cut-off point of 2, the complete and laboratory-free risk scores performed similarly well with a ROC area of 76.2% and 76.0%, respectively (P = 0.784). The best assessment parameter of these risk scores was their negative predictive value: 99.1% and 99.0% for the complete and laboratory-free, respectively. The developed risk scores showed a moderate performance as a screening test. People with a score of ≥ 2 points should undergo further testing to rule out CKD. Using the laboratory-free risk score is a practical approach in developing countries where laboratories are not readily available and undiagnosed CKD has significant morbidity and mortality.

  13. The New York risk score for in-hospital and 30-day mortality for coronary artery bypass graft surgery.

    PubMed

    Hannan, Edward L; Farrell, Louise Szypulski; Wechsler, Andrew; Jordan, Desmond; Lahey, Stephen J; Culliford, Alfred T; Gold, Jeffrey P; Higgins, Robert S D; Smith, Craig R

    2013-01-01

    Simplified risk scores for coronary artery bypass graft surgery are frequently in lieu of more complicated statistical models and are valuable for informed consent and choice of intervention. Previous risk scores have been based on in-hospital mortality, but a substantial number of patients die within 30 days of the procedure. These deaths should also be accounted for, so we have developed a risk score based on in-hospital and 30-day mortality. New York's Cardiac Surgery Reporting System was used to develop an in-hospital and 30-day logistic regression model for patients undergoing coronary artery bypass graft surgery in 2009, and this model was converted into a simple linear risk score that provides estimated in-hospital and 30-day mortality rates for different values of the score. The accuracy of the risk score in predicting mortality was tested. This score was also validated by applying it to 2008 New York coronary artery bypass graft data. Subsequent analyses evaluated the ability of the risk score to predict complications and length of stay. The overall in-hospital and 30-day mortality rate for the 10,148 patients in the study was 1.79%. There are seven risk factors comprising the score, with risk factor scores ranging from 1 to 5, and the highest possible total score is 23. The score accurately predicted mortality in 2009 as well as in 2008, and was strongly correlated with complications and length of stay. The risk score is a simple way of estimating short-term mortality that accurately predicts mortality in the year the model was developed as well as in the previous year. Perioperative complications and length of stay are also well predicted by the risk score. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. A comparison between modified Alvarado score and RIPASA score in the diagnosis of acute appendicitis.

    PubMed

    Singla, Anand; Singla, Satpaul; Singh, Mohinder; Singla, Deeksha

    2016-12-01

    Acute appendicitis is a common but elusive surgical condition and remains a diagnostic dilemma. It has many clinical mimickers and diagnosis is primarily made on clinical grounds, leading to the evolution of clinical scoring systems for pin pointing the right diagnosis. The modified Alvarado and RIPASA scoring systems are two important scoring systems, for diagnosis of acute appendicitis. We prospectively compared the two scoring systems for diagnosing acute appendicitis in 50 patients presenting with right iliac fossa pain. The RIPASA score correctly classified 88 % of patients with histologically confirmed acute appendicitis compared with 48.0 % with modified Alvarado score, indicating that RIPASA score is more superior to Modified Alvarado score in our clinical settings.

  15. Model for end-stage liver disease-based allocation system for liver transplantation in Argentina: does it work outside the United States?

    PubMed

    McCormack, L; Gadano, A; Lendoire, J; Imventarza, O; Andriani, O; Gil, O; Toselli, L; Bisigniano, L; de Santibañes, E

    2010-09-01

    In July 2005, Argentina was the first country after the United States to adopt the MELD system. The purpose of the present study was to analyse the impact of this new system on the adult liver waiting list (WL). Between 2005 and 2009, 1773 adult patients were listed for liver transplantation: 150 emergencies and 1623 electives. Elective patients were categorized using the MELD system. A prospective database was used to analyse mortality and probability to be transplanted (PTBT) on the WL. The waiting time increased inversely with the MELD score and PTBT positively correlated with MELD score. With scores >/= 18 the PTBT remained over 50%. However, the largest MELD subgroup with <10 points (n = 433) had the lower PTBT (3%). In contrast, patients with T(2) hepatocellular carcinoma benefited excessively with the highest PTBT (84.2%) and the lowest mortality rate (5.4%). The WL mortality increased after MELD adoption (10% vs. 14.8% vs. P < 0.01). Patients with <10 MELD points had >fourfold probability of dying on the WL than PTBT (14.3% vs. 3%; P < 0.0001). After MELD implementation, WL mortality increased and most patients who died had a low MELD score. A comprehensive revision of the MELD system must be performed to include cultural and socio-economical variables that could affect each country individually.

  16. Systems view of adipogenesis via novel omics-driven and tissue-specific activity scoring of network functional modules

    NASA Astrophysics Data System (ADS)

    Nassiri, Isar; Lombardo, Rosario; Lauria, Mario; Morine, Melissa J.; Moyseos, Petros; Varma, Vijayalakshmi; Nolen, Greg T.; Knox, Bridgett; Sloper, Daniel; Kaput, Jim; Priami, Corrado

    2016-07-01

    The investigation of the complex processes involved in cellular differentiation must be based on unbiased, high throughput data processing methods to identify relevant biological pathways. A number of bioinformatics tools are available that can generate lists of pathways ranked by statistical significance (i.e. by p-value), while ideally it would be desirable to functionally score the pathways relative to each other or to other interacting parts of the system or process. We describe a new computational method (Network Activity Score Finder - NASFinder) to identify tissue-specific, omics-determined sub-networks and the connections with their upstream regulator receptors to obtain a systems view of the differentiation of human adipocytes. Adipogenesis of human SBGS pre-adipocyte cells in vitro was monitored with a transcriptomic data set comprising six time points (0, 6, 48, 96, 192, 384 hours). To elucidate the mechanisms of adipogenesis, NASFinder was used to perform time-point analysis by comparing each time point against the control (0 h) and time-lapse analysis by comparing each time point with the previous one. NASFinder identified the coordinated activity of seemingly unrelated processes between each comparison, providing the first systems view of adipogenesis in culture. NASFinder has been implemented into a web-based, freely available resource associated with novel, easy to read visualization of omics data sets and network modules.

  17. Comparison of manual sleep staging with automated neural network-based analysis in clinical practice.

    PubMed

    Caffarel, Jennifer; Gibson, G John; Harrison, J Phil; Griffiths, Clive J; Drinnan, Michael J

    2006-03-01

    We have compared sleep staging by an automated neural network (ANN) system, BioSleep (Oxford BioSignals) and a human scorer using the Rechtschaffen and Kales scoring system. Sleep study recordings from 114 patients with suspected obstructed sleep apnoea syndrome (OSA) were analysed by ANN and by a blinded human scorer. We also examined human scorer reliability by calculating the agreement between the index scorer and a second independent blinded scorer for 28 of the 114 studies. For each study, we built contingency tables on an epoch-by-epoch (30 s epochs) comparison basis. From these, we derived kappa (kappa) coefficients for different combinations of sleep stages. The overall agreement of automatic and manual scoring for the 114 studies for the classification {wake / light-sleep / deep-sleep / REM} was poor (median kappa = 0.305) and only a little better (kappa = 0.449) for the crude {wake / sleep} distinction. For the subgroup of 28 randomly selected studies, the overall agreement of automatic and manual scoring was again relatively low (kappa = 0.331 for {wake light-sleep / deep-sleep REM} and kappa = 0.505 for {wake / sleep}), whereas inter-scorer reliability was higher (kappa = -0.641 for {wake / light-sleep / deep-sleep / REM} and kappa = 0.737 for {wake / sleep}). We conclude that such an ANN-based analysis system is not sufficiently accurate for sleep study analyses using the R&K classification system.

  18. Test/score/report: Simulation techniques for automating the test process

    NASA Technical Reports Server (NTRS)

    Hageman, Barbara H.; Sigman, Clayton B.; Koslosky, John T.

    1994-01-01

    A Test/Score/Report capability is currently being developed for the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) system which will automate testing of the Goddard Space Flight Center (GSFC) Payload Operations Control Center (POCC) and Mission Operations Center (MOC) software in three areas: telemetry decommutation, spacecraft command processing, and spacecraft memory load and dump processing. Automated computer control of the acceptance test process is one of the primary goals of a test team. With the proper simulation tools and user interface, the task of acceptance testing, regression testing, and repeatability of specific test procedures of a ground data system can be a simpler task. Ideally, the goal for complete automation would be to plug the operational deliverable into the simulator, press the start button, execute the test procedure, accumulate and analyze the data, score the results, and report the results to the test team along with a go/no recommendation to the test team. In practice, this may not be possible because of inadequate test tools, pressures of schedules, limited resources, etc. Most tests are accomplished using a certain degree of automation and test procedures that are labor intensive. This paper discusses some simulation techniques that can improve the automation of the test process. The TASS system tests the POCC/MOC software and provides a score based on the test results. The TASS system displays statistics on the success of the POCC/MOC system processing in each of the three areas as well as event messages pertaining to the Test/Score/Report processing. The TASS system also provides formatted reports documenting each step performed during the tests and the results of each step. A prototype of the Test/Score/Report capability is available and currently being used to test some POCC/MOC software deliveries. When this capability is fully operational it should greatly reduce the time necessary to test a POCC/MOC software delivery, as well as improve the quality of the test process.

  19. Understanding latent structures of clinical information logistics: A bottom-up approach for model building and validating the workflow composite score.

    PubMed

    Esdar, Moritz; Hübner, Ursula; Liebe, Jan-David; Hüsers, Jens; Thye, Johannes

    2017-01-01

    Clinical information logistics is a construct that aims to describe and explain various phenomena of information provision to drive clinical processes. It can be measured by the workflow composite score, an aggregated indicator of the degree of IT support in clinical processes. This study primarily aimed to investigate the yet unknown empirical patterns constituting this construct. The second goal was to derive a data-driven weighting scheme for the constituents of the workflow composite score and to contrast this scheme with a literature based, top-down procedure. This approach should finally test the validity and robustness of the workflow composite score. Based on secondary data from 183 German hospitals, a tiered factor analytic approach (confirmatory and subsequent exploratory factor analysis) was pursued. A weighting scheme, which was based on factor loadings obtained in the analyses, was put into practice. We were able to identify five statistically significant factors of clinical information logistics that accounted for 63% of the overall variance. These factors were "flow of data and information", "mobility", "clinical decision support and patient safety", "electronic patient record" and "integration and distribution". The system of weights derived from the factor loadings resulted in values for the workflow composite score that differed only slightly from the score values that had been previously published based on a top-down approach. Our findings give insight into the internal composition of clinical information logistics both in terms of factors and weights. They also allowed us to propose a coherent model of clinical information logistics from a technical perspective that joins empirical findings with theoretical knowledge. Despite the new scheme of weights applied to the calculation of the workflow composite score, the score behaved robustly, which is yet another hint of its validity and therefore its usefulness. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Understanding Variations in Medicare Consumer Assessment of Health Care Providers and Systems Scores: California as an Example

    PubMed Central

    Farley, Donna O; Elliott, Marc N; Haviland, Amelia M; Slaughter, Mary Ellen; Heller, Amy

    2011-01-01

    Objective To understand reasons why California has lower Consumer Assessment of Healthcare Providers and Systems (CAHPS) scores than the rest of the country, including differing patterns of CAHPS scores between Medicare Advantage (MA) and fee-for-service, effects of additional demographic characteristics of beneficiaries, and variation across MA plans within California. Study Design/Data Collection Using 2008 CAHPS survey data for fee-for-service Medicare beneficiaries and MA members, we compared mean case mix adjusted Medicare CAHPS scores for California and the remainder of the nation. Principal Findings California fee-for-service Medicare had lower scores than non-California fee-for-service on 11 of 14 CAHPS measures; California MA had lower scores only for physician services measures and higher scores for other measures. Adding race/ethnicity and urbanity to risk adjustment improved California standing for all measures in both MA and fee-for-service. Within the MA plans, one large plan accounted for the positive performance in California MA; other California plans performed below national averages. Conclusions This study shows that the mix of fee-for-service and MA enrollees, demographic characteristics of populations, and plan-specific factors can all play a role in observed regional variations. Anticipating value-based payments, further study of successful MA plans could generate lessons for enhancing patient experience for the Medicare population. PMID:21644970

  1. Increasing the Mobility of Dismounted Marines. Small Unit Mobility Enhancement Technologies: Unmanned Ground Vehicles Market Survey

    DTIC Science & Technology

    2009-10-01

    DARPA) Legged Squad Support System (LS3) Program. DARPA’s LS3 Program is an effort to develop a walking platform, preferably a quadruped, which...top-scoring UGV’s are track- or wheel-based; only the BigDog is a leg -based system. This presented BigDog with certain advantages (particularly...Technologies, Inc.’s ( DTI ) first location in Ranlo, North Carolina) – is a system capable of wheeled or tracked locomotion and was recently

  2. Geospatial Information System Analysis of Healthcare Need and Telemedicine Delivery in California.

    PubMed

    Kaufman, Taylor; Geraghty, Estella M; Dullet, Navjit; King, Jesse; Kissee, Jamie; Marcin, James P

    2017-05-01

    Geospatial Information Systems (GIS) superimpose data on geographical maps to provide visual representations of data by region. Few studies have used GIS data to investigate if telemedicine services are preferentially provided to communities of greatest need. This study compared the healthcare needs of communities with and without telemedicine services from a university-based telemedicine program. Originating sites for all telemedicine consultations between July 1996 and December 2013 were geocoded using ArcGIS software. ZIP Code Tabulation Areas (ZCTAs) were extracted from the 2010 U.S. Census Bureau's Topologically Integrated Geographic Encoding and Referencing file and assigned a community needs index (CNI) score to reflect the ZCTA community's healthcare needs based on evidence-based barriers to healthcare access. CNI scores were compared across communities with and without active telemedicine services. One hundred ninety-four originating telemedicine clinic sites in California were evaluated. The mean CNI score for ZCTAs with at least one telemedicine clinic was significantly higher (3.32 ± 0.84) than those without a telemedicine site (2.95 ± 0.99) and higher than the mean ZCTAs for all of California (2.99 ± 1.01). Of the 194 telemedicine clinics, 71.4% were located in communities with above average need and 33.2% were located in communities with very high needs. Originating sites receiving telemedicine services from a university-based telemedicine program were located in regions with significantly higher community healthcare needs. Leveraging a geospatial information system to understand community healthcare needs provides an opportunity for payers, hospitals, and patients to be strategic in the allocation of telemedicine services.

  3. The Veterans Affairs Cardiac Risk Score: Recalibrating the Atherosclerotic Cardiovascular Disease Score for Applied Use.

    PubMed

    Sussman, Jeremy B; Wiitala, Wyndy L; Zawistowski, Matthew; Hofer, Timothy P; Bentley, Douglas; Hayward, Rodney A

    2017-09-01

    Accurately estimating cardiovascular risk is fundamental to good decision-making in cardiovascular disease (CVD) prevention, but risk scores developed in one population often perform poorly in dissimilar populations. We sought to examine whether a large integrated health system can use their electronic health data to better predict individual patients' risk of developing CVD. We created a cohort using all patients ages 45-80 who used Department of Veterans Affairs (VA) ambulatory care services in 2006 with no history of CVD, heart failure, or loop diuretics. Our outcome variable was new-onset CVD in 2007-2011. We then developed a series of recalibrated scores, including a fully refit "VA Risk Score-CVD (VARS-CVD)." We tested the different scores using standard measures of prediction quality. For the 1,512,092 patients in the study, the Atherosclerotic cardiovascular disease risk score had similar discrimination as the VARS-CVD (c-statistic of 0.66 in men and 0.73 in women), but the Atherosclerotic cardiovascular disease model had poor calibration, predicting 63% more events than observed. Calibration was excellent in the fully recalibrated VARS-CVD tool, but simpler techniques tested proved less reliable. We found that local electronic health record data can be used to estimate CVD better than an established risk score based on research populations. Recalibration improved estimates dramatically, and the type of recalibration was important. Such tools can also easily be integrated into health system's electronic health record and can be more readily updated.

  4. Use of an adaptive neuro-fuzzy inference system to obtain the correspondence among balance, gait, and depression for Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Woo, Youngkeun; Lee, Juwon; Hwang, Sujin; Hong, Cheol Pyo

    2013-03-01

    The purpose of this study was to investigate the associations between gait performance, postural stability, and depression in patients with Parkinson's disease (PD) by using an adaptive neuro-fuzzy inference system (ANFIS). Twenty-two idiopathic PD patients were assessed during outpatient physical therapy by using three clinical tests: the Berg balance scale (BBS), Dynamic gait index (DGI), and Geriatric depression scale (GDS). Scores were determined from clinical observation and patient interviews, and associations among gait performance, postural stability, and depression in this PD population were evaluated. The DGI showed significant positive correlation with the BBS scores, and negative correlation with the GDS score. We assessed the relationship between the BBS score and the DGI results by using a multiple regression analysis. In this case, the GDS score was not significantly associated with the DGI, but the BBS and DGI results were. Strikingly, the ANFIS-estimated value of the DGI, based on the BBS and the GDS scores, significantly correlated with the walking ability determined by using the DGI in patients with Parkinson's disease. These findings suggest that the ANFIS techniques effectively reflect and explain the multidirectional phenomena or conditions of gait performance in patients with PD.

  5. A real-time stress classification system based on arousal analysis of the nervous system by an F-state machine.

    PubMed

    Martinez, R; Irigoyen, E; Arruti, A; Martin, J I; Muguerza, J

    2017-09-01

    Detection and labelling of an increment in the human stress level is a contribution focused principally on improving the quality of life of people. This work is aimed to develop a biophysical real-time stress identification and classification system, analysing two noninvasive signals, the galvanic skin response and the heart rate variability. An experimental procedure was designed and configured in order to elicit a stressful situation that is similar to those found in real cases. A total of 166 subjects participated in this experimental stage. The set of registered signals of each subject was considered as one experiment. A preliminary qualitative analysis of the signals collected was made, based on previous counselling received from neurophysiologists and psychologists. This study revealed a relationship between changes in the temporal signals and the induced stress states in each subject. To identify and classify such states, a subsequent quantitative analysis was performed in order to determine specific numerical information related to the above mentioned relationship. This second analysis gives the particular details to design the finally proposed classification algorithm, based on a Finite State Machine. The proposed system is able to classify the detected stress stages at three levels: low, medium, and high. Furthermore, the system identifies persistent stress situations or momentary alerts, depending on the subject's arousal. The system reaches an F 1 score of 0.984 in the case of high level, an F 1 score of 0.970 for medium level, and an F 1 score of 0.943 for low level. The resulting system is able to detect and classify different stress stages only based on two non invasive signals. These signals can be collected in people during their monitoring and be processed in a real-time sense, as the system can be previously preconfigured. Therefore, it could easily be implemented in a wearable prototype that could be worn by end users without feeling to be monitored. Besides, due to its low computational, the computation of the signals slopes is easy to do and its deployment in real-time applications is feasible. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Scoring systems for outcome prediction in patients with perforated peptic ulcer

    PubMed Central

    2013-01-01

    Background Patients with perforated peptic ulcer (PPU) often present with acute, severe illness that carries a high risk for morbidity and mortality. Mortality ranges from 3-40% and several prognostic scoring systems have been suggested. The aim of this study was to review the available scoring systems for PPU patients, and to assert if there is evidence to prefer one to the other. Material and methods We searched PubMed for the mesh terms “perforated peptic ulcer”, “scoring systems”, “risk factors”, ”outcome prediction”, “mortality”, ”morbidity” and the combinations of these terms. In addition to relevant scores introduced in the past (e.g. Boey score), we included recent studies published between January 2000 and December 2012) that reported on scoring systems for prediction of morbidity and mortality in PPU patients. Results A total of ten different scoring systems used to predict outcome in PPU patients were identified; the Boey score, the Hacettepe score, the Jabalpur score the peptic ulcer perforation (PULP) score, the ASA score, the Charlson comorbidity index, the sepsis score, the Mannheim Peritonitis Index (MPI), the Acute physiology and chronic health evaluation II (APACHE II), the simplified acute physiology score II (SAPS II), the Mortality probability models II (MPM II), the Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity physical sub-score (POSSUM-phys score). Only four of the scores were specifically constructed for PPU patients. In five studies the accuracy of outcome prediction of different scoring systems was evaluated by receiver operating characteristics curve (ROC) analysis, and the corresponding area under the curve (AUC) among studies compared. Considerable variation in performance both between different scores and between different studies was found, with the lowest and highest AUC reported between 0.63 and 0.98, respectively. Conclusion While the Boey score and the ASA score are most commonly used to predict outcome for PPU patients, considerable variations in accuracy for outcome prediction were shown. Other scoring systems are hampered by a lack of validation or by their complexity that precludes routine clinical use. While the PULP score seems promising it needs external validation before widespread use. PMID:23574922

  7. Identification of Balance Deficits in People with Parkinson Disease; is the Sensory Organization Test Enough?

    PubMed

    Gera, G; Freeman, D L; Blackinton, M T; Horak, F B; King, L

    2016-02-01

    Balance deficits in people with Parkinson's disease can affect any of the multiple systems encompassing balance control. Thus, identification of the specific deficit is crucial in customizing balance rehabilitation. The sensory organization test, a test of sensory integration for balance control, is sometimes used in isolation to identify balance deficits in people with Parkinson's disease. More recently, the Mini-Balance Evaluations Systems Test, a clinical scale that tests multiple domains of balance control, has begun to be used to assess balance in patients with Parkinson's disease. The purpose of our study was to compare the use of Sensory Organization Test and Mini-Balance Evaluations Systems Test in identifying balance deficits in people with Parkinson's disease. 45 participants (27M, 18F; 65.2 ± 8.2 years) with idiopathic Parkinson's disease participated in the cross-sectional study. Balance assessment was performed using the Sensory Organization Test and the Mini-Balance Evaluations Systems Test. People were classified into normal and abnormal balance based on the established cutoff scores (normal balance: Sensory Organization Test >69; Mini-Balance Evaluations Systems Test >73). More subjects were classified as having abnormal balance with the Mini-Balance Evaluations Systems Test (71% abnormal) than with the Sensory Organization Test (24% abnormal) in our cohort of people with Parkinson's disease. There were no subjects with a normal Mini-Balance Evaluations Systems Test score but abnormal Sensory Organization Test score. In contrast, there were 21 subjects who had an abnormal Mini-Balance Evaluations Systems Test score but normal Sensory Organization Test scores. Findings from this study suggest that investigation of sensory integration deficits, alone, may not be able to identify all types of balance deficits found in patients with Parkinson's disease. Thus, a comprehensive approach should be used to test of multiple balance systems to provide customized rehabilitation.

  8. An electrocardiographic scoring system for distinguishing right ventricular outflow tract arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy from idiopathic ventricular tachycardia.

    PubMed

    Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M

    2013-04-01

    Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. The thromboelastometric discrepancy between septic and trauma induced disseminated intravascular coagulation diagnosed by the scoring system from the Japanese association for acute medicine.

    PubMed

    Koami, Hiroyuki; Sakamoto, Yuichiro; Sakurai, Ryota; Ohta, Miho; Imahase, Hisashi; Yahata, Mayuko; Umeka, Mitsuru; Miike, Toru; Nagashima, Futoshi; Iwamura, Takashi; Yamada, Kosuke Chris; Inoue, Satoshi

    2016-08-01

    The aim of this study is to evaluate the hematological differences between septic and traumatic disseminated intravascular coagulation (DIC) using the rotational thromboelastometry (ROTEM).This retrospective study includes all sepsis or severe trauma patients transported to our emergency department who underwent ROTEM from 2013 to 2014. All patients were divided into 2 groups based on the presence of DIC diagnosed by the Japanese Association for Acute Medicine (JAAM) DIC score. We statistically analyzed the demographics, clinical characteristics, laboratory data, ROTEM findings (EXTEM and FIBTEM), and outcome.Fifty-seven patients (30 sepsis and 27 severe trauma) were included in primary analysis. Sepsis cases were significantly older and had higher systemic inflammatory response syndrome (SIRS) scores, whereas there were no significant differences in other parameters including Acute Physiology and Chronic Health Evaluation (APACHE) II score, sequential organ failure assessment (SOFA) score. Twenty-six patients (14 sepsis and 12 severe trauma) were diagnosed with DIC. The Septic DIC (S-DIC) group was significantly older and had higher DIC scores than the traumatic DIC (T-DIC) group. Hematologic examination revealed significantly higher CRP, fibrinogen, lower FDP, DD, and higher FDP/DD ratio were found in the S-DIC group in comparison with the T-DIC group. ROTEM findings showed that the A10, A20, and MCF in the FIBTEM test were significantly higher in the S-DIC group. However, no statistical differences were confirmed in the LI30, LI45, and ML in EXTEM test.The plasma fibrinogen level and fibrinogen based clot firmness in whole-blood test revealed statistical significance between septic and traumatic DIC patients.

  10. Defining High Risk Patients for Endovascular Aneurysm Repair: A National Analysis

    PubMed Central

    Egorova, Natalia; Giacovelli, Jeannine K.; Gelijns, Annetine; Mureebe, Leila; Greco, Giampaolo; Morrissey, Nicholas; Nowygrod, Roman; Moskowitz, Alan; McKinsey, James; Kent, K. Craig

    2011-01-01

    Background Endovascular aneurysm repair (EVAR) is commonly used as a minimally invasive technique for repairing infrarenal aortic aneurysms. There have been recent concerns that a subset of high-risk patients experience unfavorable outcomes with this intervention. To determine whether such a high-risk cohort exists and to identify the characteristics of these patients, we analyzed the outcomes of Medicare patients treated with EVAR from 2000–2006. Methods and Results We identified 66,943 patients who underwent EVAR from Inpatient Medicare database. The overall 30-day mortality was 1.6%. A risk model for perioperative mortality was developed by randomly selecting 44,630 patients; the other 1/3 of the dataset was used to validate the model. The model was deemed reliable (Hosmer-Lemeshow statistics was p=0.25 for the development, p=0.24 for the validation model) and accurate (c=0.735 and c=0.731 for the development and the validation model, respectively). In our scoring system, where scores ranged between 1 and 7, the following were identified as significant baseline factors that predict mortality: renal failure with dialysis (score=7), renal failure without dialysis (score=3), clinically significant lower extremity ischemia (score=5), patient age ≥85 (score=3), 75–84 (score=2), 70–74 (score=1), heart failure (score=3), chronic liver disease (score=3), female gender (score=2), neurological disorders (score=2), , chronic pulmonary disease (score=2), surgeon experience in EVAR<3 procedures (score=1) and hospital annual volume in EVAR <7 procedures (score=1). The majority of Medicare patients who were treated (96.6%, n=64,651) had a score of 9 or less, which correlated with a mortality < 5%. Only 3.4% of patients had a mortality ≥ 5% and 0.8% of patients (n=509) had a score of 13 or higher, which correlated with a mortality >10%. Conclusion We conclude that there is a high-risk cohort of patients that should not be treated with EVAR; however, this cohort is small. Our scoring system, which is based on patient and institutional factors, provides criteria that can be easily used by clinicians to quantify perioperative risk for EVAR candidates. PMID:19782526

  11. How Have State Level Standards-Based Tests Related to Norm-Referenced Tests in Alaska?.

    ERIC Educational Resources Information Center

    Fenton, Ray

    This overview of the Alaska system for test development, scoring, and reporting explored differences and similarities between norm-referenced and standards-based tests. The current Alaska testing program is based on legislation passed in 1997 and 1998, and is designed to meet the requirements of the federal No Child Left Behind Legislation. In…

  12. External validation of the simple clinical score and the HOTEL score, two scores for predicting short-term mortality after admission to an acute medical unit.

    PubMed

    Stræde, Mia; Brabrand, Mikkel

    2014-01-01

    Clinical scores can be of aid to predict early mortality after admission to a medical admission unit. A developed scoring system needs to be externally validated to minimise the risk of the discriminatory power and calibration to be falsely elevated. We performed the present study with the objective of validating the Simple Clinical Score (SCS) and the HOTEL score, two existing risk stratification systems that predict mortality for medical patients based solely on clinical information, but not only vital signs. Pre-planned prospective observational cohort study. Danish 460-bed regional teaching hospital. We included 3046 consecutive patients from 2 October 2008 until 19 February 2009. 26 (0.9%) died within one calendar day and 196 (6.4%) died within 30 days. We calculated SCS for 1080 patients. We found an AUROC of 0.960 (95% confidence interval [CI], 0.932 to 0.988) for 24-hours mortality and 0.826 (95% CI, 0.774-0.879) for 30-day mortality, and goodness-of-fit test, χ(2) = 2.68 (10 degrees of freedom), P = 0.998 and χ(2) = 4.00, P = 0.947, respectively. We included 1470 patients when calculating the HOTEL score. Discriminatory power (AUROC) was 0.931 (95% CI, 0.901-0.962) for 24-hours mortality and goodness-of-fit test, χ(2) = 5.56 (10 degrees of freedom), P = 0.234. We find that both the SCS and HOTEL scores showed an excellent to outstanding ability in identifying patients at high risk of dying with good or acceptable precision.

  13. Ocular manifestation in Marfan syndrome: corneal biomechanical properties relate to increased systemic score points.

    PubMed

    Scheibenberger, Dido; Frings, Andreas; Steinberg, Johannes; Schüler, Helke; Druchkiv, Vasyl; Katz, Toam; von Kodolitsch, Yskert; Linke, Stephan

    2018-06-01

    To evaluate corneal deformation to an air puff as a new noninvasive tool to document disease status in Marfan syndrome (MFS) METHODS: Prospective observational cohort study. We included patients diagnosed with MFS who had their routine cardiovascular follow-up and applied the revised Ghent nosology to define two subgroups according to a high (≥ 7) and a low (< 7 points) systemic score. Dynamic Scheimpflug-based biomechanical analyses (CorvisST® [CST; Oculus GmbH]) were performed. The main outcome measure was the displacement of the corneal apex as given by the parameters highest concavity (HC; in ms), peak distance (PD; in mm), and highest concavity deformation amplitude (DA; mm). Forty-three eyes of 43 individuals (19 female, 24 male; mean age 42.0 ± 12.0 years, range 18-67 years) diagnosed with MFS were included. Applying the Ghent criteria, 21 patients had an advanced systemic score of ≥ 7, and 22 had score points < 7. There were no differences in age or sex between both groups. In contrast, HC was faster (P = 0.004), and PD (P < 0.001) was longer in those individuals with systemic score ≥ 7; maximum DA did not result in a statistically significant difference between the groups (P = 0.250). In vivo noninvasive biomechanical analyses with CST offer a new, non-invasive method to identify pathologic corneal deformation responses in adults with MFS. In the future, corneal deformation to an air puff could thus assist early identification of patients with high Ghent score as an adjunct to existing diagnostic tests.

  14. Firefighter hearing health: an informatics approach to screening, measurement, and research.

    PubMed

    Hong, OiSaeng; Monsen, Karen A; Kerr, Madeleine J; Chin, Dal Lae; Lytton, Amy B; Martin, Karen S

    2012-10-01

    The purpose of this study was to evaluate the use of a standardized interface terminology, the Omaha System, with respect to noise-induced hearing loss (NIHL). A descriptive, correlational design was employed for this secondary analysis with the data from an ongoing hearing protection intervention study. A total of 346 firefighters were included. First, an evidence-based standardized care plan (EB-SCP) for hearing screening was developed and validated by clinical experts. Second, occupational health records were used to compute Omaha System Knowledge, Behavior, and Status outcomes. Third, research data were mapped to Omaha System rating scales. For Knowledge, the mean score was close to 'adequate' (3.7). For Behavior, the mean score was close to 'rarely appropriate' (2.2). For Status, the mean score was close to 'minimal sign/symptom' (4.4). Significant positive relationships were found between Knowledge and Behavior (Spearman's rho =.13, p =.01), and between Behavior and hearing Status (Spearman's rho =.12, p =.02). Findings support the validity of the new Knowledge, Behavior, and hearing Status. Informatics methods such as the standardized NIHL EB-SCP and outcome data sets will create opportunities for clinical decision support and data exchange across various health care settings, thus supporting population-based hearing health assessments and outcomes.

  15. Chi-square-based scoring function for categorization of MEDLINE citations.

    PubMed

    Kastrin, A; Peterlin, B; Hristovski, D

    2010-01-01

    Text categorization has been used in biomedical informatics for identifying documents containing relevant topics of interest. We developed a simple method that uses a chi-square-based scoring function to determine the likelihood of MEDLINE citations containing genetic relevant topic. Our procedure requires construction of a genetic and a nongenetic domain document corpus. We used MeSH descriptors assigned to MEDLINE citations for this categorization task. We compared frequencies of MeSH descriptors between two corpora applying chi-square test. A MeSH descriptor was considered to be a positive indicator if its relative observed frequency in the genetic domain corpus was greater than its relative observed frequency in the nongenetic domain corpus. The output of the proposed method is a list of scores for all the citations, with the highest score given to those citations containing MeSH descriptors typical for the genetic domain. Validation was done on a set of 734 manually annotated MEDLINE citations. It achieved predictive accuracy of 0.87 with 0.69 recall and 0.64 precision. We evaluated the method by comparing it to three machine-learning algorithms (support vector machines, decision trees, naïve Bayes). Although the differences were not statistically significantly different, results showed that our chi-square scoring performs as good as compared machine-learning algorithms. We suggest that the chi-square scoring is an effective solution to help categorize MEDLINE citations. The algorithm is implemented in the BITOLA literature-based discovery support system as a preprocessor for gene symbol disambiguation process.

  16. Pharmacophore-Based Similarity Scoring for DOCK

    PubMed Central

    2015-01-01

    Pharmacophore modeling incorporates geometric and chemical features of known inhibitors and/or targeted binding sites to rationally identify and design new drug leads. In this study, we have encoded a three-dimensional pharmacophore matching similarity (FMS) scoring function into the structure-based design program DOCK. Validation and characterization of the method are presented through pose reproduction, crossdocking, and enrichment studies. When used alone, FMS scoring dramatically improves pose reproduction success to 93.5% (∼20% increase) and reduces sampling failures to 3.7% (∼6% drop) compared to the standard energy score (SGE) across 1043 protein–ligand complexes. The combined FMS+SGE function further improves success to 98.3%. Crossdocking experiments using FMS and FMS+SGE scoring, for six diverse protein families, similarly showed improvements in success, provided proper pharmacophore references are employed. For enrichment, incorporating pharmacophores during sampling and scoring, in most cases, also yield improved outcomes when docking and rank-ordering libraries of known actives and decoys to 15 systems. Retrospective analyses of virtual screenings to three clinical drug targets (EGFR, IGF-1R, and HIVgp41) using X-ray structures of known inhibitors as pharmacophore references are also reported, including a customized FMS scoring protocol to bias on selected regions in the reference. Overall, the results and fundamental insights gained from this study should benefit the docking community in general, particularly researchers using the new FMS method to guide computational drug discovery with DOCK. PMID:25229837

  17. School Centered Evidence Based Accountability

    ERIC Educational Resources Information Center

    Milligan, Charles

    2015-01-01

    Achievement scores drive much of the effort in today's accountability system, however, there is much more that occurs in every school, every day. School Centered Evidence Based Accountability can be used from micro to macro giving School Boards and Administration a process for monitoring the results of the entire school operation effectively and…

  18. A new scoring model for characterization of adnexal masses based on two-dimensional gray-scale and colour Doppler sonographic features

    PubMed Central

    Abbas, A.M.; Zahran, K.M.; Nasr, A.; Kamel, H.S.

    2014-01-01

    Objective: To determine the most discriminating two-dimensional gray-scale and colour Doppler sonographic features that allow differentiation between malignant and benign adnexal masses, and to develop a scoring model that would enable more accurate diagnosis with those features. Methods: A cross sectional prospective study was conducted on patients scheduled for surgery due to presence of adnexal masses at Woman’s Health Center, Assiut University, Egypt between October 2012 and October 2013. All patients were evaluated by 2D ultrasound for morphological features of the masses combined with colour Doppler examination of their vessels. The final diagnosis, based on histopathological analysis, was used as a gold standard. Results: One hundred forty-six patients were recruited, 104 with benign masses, 42 with malignant masses. Features that allowed statistically significant discrimination of benignity from malignancy were; volume of mass, type of mass, presence and thickness of septae, presence and length of papillary projections, location of vessels at colour Doppler and colour score. A scoring model was formulated combining these features together; Assiut Scoring Model (ASM). The cut-off level with the highest accuracy in detection of malignancy, was ≥6, had a sensitivity of 93.5% and specificity of 92.2%. Conclusion: Our Scoring Model; a multiparameter scoring using four gray-scale ultrasound and two colour Doppler features, had shown a high sensitivity and specificity for prediction of malignancy in adnexal masses compared with previous scoring systems. PMID:25009729

  19. A dual-task home-based rehabilitation programme for improving balance control in patients with acquired brain injury: a single-blind, randomized controlled pilot study.

    PubMed

    Peirone, Eliana; Goria, Paolo Filiberto; Anselmino, Arianna

    2014-04-01

    To evaluate the safety, feasibility and effectiveness of a dual-task home-based rehabilitation programme on balance impairments among adult patients with acquired brain injury. Single-blind, randomized controlled pilot study. Single rehabilitation centre. Sixteen participants between 12 and 18 months post-acquired brain injury with balance impairments and a score <10 seconds on the One-Leg Stance Test (eyes open). All participants received 50-minutes individualised traditional physiotherapy sessions three times a week for seven weeks. In addition, the intervention group (N = 8) performed an individualised dual-task home-based programme six days a week for seven weeks. The primary outcome measure was the Balance Evaluation System Test; secondary measures were the Activities-specific Balance Confidence Scale and Goal Attainment Scaling. At the end of the pilot study, the intervention group showed significantly greater improvement in Balance Evaluation System Test scores (17.87, SD 6.05) vs. the control group (5.5, SD 3.53; P = 0.008, r = 0.63). There was no significant difference in improvement in Activities-specific Balance Confidence Scale scores between the intervention group (25.25, SD 25.51) and the control group (7.00, SD 14.73; P = 0.11, r = 0.63). There was no significant improvement in Goal Attainment Scaling scores in the intervention (19.37, SD 9.03) vs. the control group (16.28, SD 6.58; P = 0.093, r = 0.63). This pilot study shows the safety, feasibility and short-term benefit of a dual-task home-based rehabilitation programme to improve balance control in patients with acquired brain injury. A sample size of 26 participants is required for a definitive study.

  20. Improving binding mode and binding affinity predictions of docking by ligand-based search of protein conformations: evaluation in D3R grand challenge 2015

    NASA Astrophysics Data System (ADS)

    Xu, Xianjin; Yan, Chengfei; Zou, Xiaoqin

    2017-08-01

    The growing number of protein-ligand complex structures, particularly the structures of proteins co-bound with different ligands, in the Protein Data Bank helps us tackle two major challenges in molecular docking studies: the protein flexibility and the scoring function. Here, we introduced a systematic strategy by using the information embedded in the known protein-ligand complex structures to improve both binding mode and binding affinity predictions. Specifically, a ligand similarity calculation method was employed to search a receptor structure with a bound ligand sharing high similarity with the query ligand for the docking use. The strategy was applied to the two datasets (HSP90 and MAP4K4) in recent D3R Grand Challenge 2015. In addition, for the HSP90 dataset, a system-specific scoring function (ITScore2_hsp90) was generated by recalibrating our statistical potential-based scoring function (ITScore2) using the known protein-ligand complex structures and the statistical mechanics-based iterative method. For the HSP90 dataset, better performances were achieved for both binding mode and binding affinity predictions comparing with the original ITScore2 and with ensemble docking. For the MAP4K4 dataset, although there were only eight known protein-ligand complex structures, our docking strategy achieved a comparable performance with ensemble docking. Our method for receptor conformational selection and iterative method for the development of system-specific statistical potential-based scoring functions can be easily applied to other protein targets that have a number of protein-ligand complex structures available to improve predictions on binding.

Top