Sample records for screen reader software

  1. Toward Software Both Seen and Heard.

    ERIC Educational Resources Information Center

    Lazzaro, Joseph J.

    1996-01-01

    Visually impaired users are hampered by current PC software written for graphical user interfaces. Screen readers that vocalize displayed text require standardization that remains missing in the programming industry; the readers cannot interpret many cues in the Windows environment. More programming standards and adaptive technology for computers…

  2. High-throughput measurements of biochemical responses using the plate::vision multimode 96 minilens array reader.

    PubMed

    Huang, Kuo-Sen; Mark, David; Gandenberger, Frank Ulrich

    2006-01-01

    The plate::vision is a high-throughput multimode reader capable of reading absorbance, fluorescence, fluorescence polarization, time-resolved fluorescence, and luminescence. Its performance has been shown to be quite comparable with other readers. When the reader is integrated into the plate::explorer, an ultrahigh-throughput screening system with event-driven software and parallel plate-handling devices, it becomes possible to run complicated assays with kinetic readouts in high-density microtiter plate formats for high-throughput screening. For the past 5 years, we have used the plate::vision and the plate::explorer to run screens and have generated more than 30 million data points. Their throughput, performance, and robustness have speeded up our drug discovery process greatly.

  3. Accelerated Reader: Evaluation Report and Executive Summary

    ERIC Educational Resources Information Center

    Gorard, Stephen; Siddiqui, Nadia; See, Beng Huat

    2015-01-01

    Accelerated Reader (AR) is a whole-group reading management and monitoring program that aims to foster the habit of independent reading among primary and early secondary age pupils. The internet-based software initially screens pupils according to their reading levels, and suggests books that match their reading age and reading interest. Pupils…

  4. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection.

    PubMed

    van Zelst, J C M; Tan, T; Platel, B; de Jong, M; Steenbakkers, A; Mourits, M; Grivegnee, A; Borelli, C; Karssemeijer, N; Mann, R M

    2017-04-01

    To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n=40) with >1year of follow up, benign (n=30) lesions that were either biopsied or remained stable, and malignant lesions (n=20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p=0.001). Sensitivity of all readers improved (range 5.2-10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4-5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    PubMed

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  6. A Computer Supported Teamwork Project for People with a Visual Impairment.

    ERIC Educational Resources Information Center

    Hale, Greg

    2000-01-01

    Discussion of the use of computer supported teamwork (CSTW) in team-based organizations focuses on problems that visually impaired people have reading graphical user interface software via screen reader software. Describes a project that successfully used email for CSTW, and suggests issues needing further research. (LRW)

  7. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    PubMed

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  8. Changing case Order to Optimise patterns of Performance in mammography Screening (CO-OPS): study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background X-ray mammography remains the predominant test for screening for breast cancer, with the aim of reducing breast cancer mortality. In the English NHS Breast Screening Programme each woman’s mammograms are examined separately by two expert readers. The two readers read each batch in the same order and each indicates if there should be recall for further tests. This is a highly skilled, pressurised, repetitive and frequently intellectually unchallenging activity where readers examine one or more batches of 30–50 women’s mammograms in each session. A vigilance decrement or performance decrease over time has been observed in similar repetitive visual tasks such as radar operation. Methods/Design The CO-OPS study is a pragmatic, multi-centre, two-arm, double blind cluster randomised controlled trial of a computer software intervention designed to reduce the effects of a vigilance decrement in breast cancer screening. The unit of randomisation is the batch. Intervention batches will be examined in the opposite order by the two readers (one forwards, one backwards). Control batches will be read in the same order as one another, as is current standard practice. The hypothesis is that cancer detection rates will be higher in the intervention group because each readers’ peak performance will occur when examining different women’s mammograms. The trial will take place in 44 English breast screening centres for 1 year and 4 months. The primary outcome is cancer detection rate, which will be extracted from computer records after 1 year of the trial. The secondary outcomes include rate of disagreement between readers (a more statistically powerful surrogate for cancer detection rate), recall rate, positive predictive value, and interval cancer rate (cancers found between screening rounds which will be measured three years after the end of the trial). Discussion This is the first trial of an intervention to ameliorate a vigilance decrement in breast cancer screening. Trial registration ISRCTN46603370 (submitted: 24 October 2012, date of registration: 26 March 2013). PMID:24411004

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    The system is developed to collect, process, store and present the information provided by the radio frequency identification (RFID) devices. The system contains three parts, the application software, the database and the web page. The application software manages multiple RFID devices, such as readers and portals, simultaneously. It communicates with the devices through application programming interface (API) provided by the device vendor. The application software converts data collected by the RFID readers and portals to readable information. It is capable of encrypting data using 256 bits advanced encryption standard (AES). The application software has a graphical user interface (GUI). Themore » GUI mimics the configurations of the nucler material storage sites or transport vehicles. The GUI gives the user and system administrator an intuitive way to read the information and/or configure the devices. The application software is capable of sending the information to a remote, dedicated and secured web and database server. Two captured screen samples, one for storage and transport, are attached. The database is constructed to handle a large number of RFID tag readers and portals. A SQL server is employed for this purpose. An XML script is used to update the database once the information is sent from the application software. The design of the web page imitates the design of the application software. The web page retrieves data from the database and presents it in different panels. The user needs a user name combined with a password to access the web page. The web page is capable of sending e-mail and text messages based on preset criteria, such as when alarm thresholds are excceeded. A captured screen sample is attached. The application software is designed to be installed on a local computer. The local computer is directly connected to the RFID devices and can be controlled locally or remotely. There are multiple local computers managing different sites or transport vehicles. The control from remote sites and information transmitted to a central database server is through secured internet. The information stored in the central databaser server is shown on the web page. The users can view the web page on the internet. A dedicated and secured web and database server (https) is used to provide information security.« less

  10. A Sign Language Screen Reader for Deaf

    NASA Astrophysics Data System (ADS)

    El Ghoul, Oussama; Jemni, Mohamed

    Screen reader technology has appeared first to allow blind and people with reading difficulties to use computer and to access to the digital information. Until now, this technology is exploited mainly to help blind community. During our work with deaf people, we noticed that a screen reader can facilitate the manipulation of computers and the reading of textual information. In this paper, we propose a novel screen reader dedicated to deaf. The output of the reader is a visual translation of the text to sign language. The screen reader is composed by two essential modules: the first one is designed to capture the activities of users (mouse and keyboard events). For this purpose, we adopted Microsoft MSAA application programming interfaces. The second module, which is in classical screen readers a text to speech engine (TTS), is replaced by a novel text to sign (TTSign) engine. This module converts text into sign language animation based on avatar technology.

  11. The use of lower resolution viewing devices for mammographic interpretation: implications for education and training.

    PubMed

    Chen, Yan; James, Jonathan J; Turnbull, Anne E; Gale, Alastair G

    2015-10-01

    To establish whether lower resolution, lower cost viewing devices have the potential to deliver mammographic interpretation training. On three occasions over eight months, fourteen consultant radiologists and reporting radiographers read forty challenging digital mammography screening cases on three different displays: a digital mammography workstation, a standard LCD monitor, and a smartphone. Standard image manipulation software was available for use on all three devices. Receiver operating characteristic (ROC) analysis and ANOVA (Analysis of Variance) were used to determine the significance of differences in performance between the viewing devices with/without the application of image manipulation software. The effect of reader's experience was also assessed. Performance was significantly higher (p < .05) on the mammography workstation compared to the other two viewing devices. When image manipulation software was applied to images viewed on the standard LCD monitor, performance improved to mirror levels seen on the mammography workstation with no significant difference between the two. Image interpretation on the smartphone was uniformly poor. Film reader experience had no significant effect on performance across all three viewing devices. Lower resolution standard LCD monitors combined with appropriate image manipulation software are capable of displaying mammographic pathology, and are potentially suitable for delivering mammographic interpretation training. • This study investigates potential devices for training in mammography interpretation. • Lower resolution standard LCD monitors are potentially suitable for mammographic interpretation training. • The effect of image manipulation tools on mammography workstation viewing is insignificant. • Reader experience had no significant effect on performance in all viewing devices. • Smart phones are not suitable for displaying mammograms.

  12. Easy PC Astronomy

    NASA Astrophysics Data System (ADS)

    Duffett-Smith, Peter

    1996-11-01

    Easy PC Astronomy is the perfect book for everyone who wants to make easy and accurate astronomical calculations. The author supplies a simple but powerful script language called AstroScript on a disk, ready to use on any IBM PC-type computer. Equipped with this software, readers can compute complex but interesting astronomical results within minutes: from the time of moonrise or moonset anywhere in the world on any date, to the display of a lunar or solar eclipse on the computer screen--all within a few minutes of opening the book! The Sky Graphics feature of the software displays a detailed image of the sky as seen from any point on earth--at any time in the future or past--showing the constellations, planets, and a host of other features. Readers need no expert knowledge of astronomy, math or programming; the author provides full details of the calculations and formulas, which the reader can absorb or ignore as desired, and a comprehensive glossary of astronomical terms. Easy PC Astronomy is of immediate practical use to beginning and advanced amateur astronomers, students at all levels, science teachers, and research astronomers. Peter Duffett-Smith is at the Cavendish Laboratory of the University of Cambridge and is the author of Astronomy with Your Personal Computer (Cambridge University Press, 1990) and Practical Astronomy with Your Calculator (Cambridge University Press, 1989).

  13. Effects of text-to-speech software use on the reading proficiency of high school struggling readers.

    PubMed

    Park, Hye Jin; Takahashi, Kiriko; Roberts, Kelly D; Delise, Danielle

    2017-01-01

    The literature highlights the benefits of text-to-speech (TTS) software when used as an assistive technology facilitating struggling readers' access to print. However, the effects of TTS software use, upon students' unassisted reading proficiency, have remained relatively unexplored. The researchers utilized an experimental design to investigate whether 9th grade struggling readers who use TTS software to read course materials demonstrate significant improvements in unassisted reading performance. A total of 164 students of 30 teachers in Hawaii participated in the study. Analyses of covariance results indicated that the TTS intervention had a significant, positive effect on student reading vocabulary and reading comprehension after 10 weeks of TTS software use (average 582 minutes). There are several limitations to the study; however, the current study opens up for discussions and need for further studies investigating TTS software as a viable reading intervention for adolescent struggling readers.

  14. Bimodal Reading: Benefits of a Talking Computer for Average and Less Skilled Readers.

    ERIC Educational Resources Information Center

    Montali, Julie; Lewandowski, Lawrence

    1996-01-01

    Eighteen average readers and 18 less-skilled readers (grades 8 and 9) were presented with social studies and science passages via a computer either visually (on screen), auditorily (read by digitized voice), or bimodally (on screen, highlighted while being voiced). Less-skilled readers demonstrated comprehension in the bimodal condition equivalent…

  15. THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER.

    PubMed

    Hansson, Jonny; Månsson, Lars Gunnar; Båth, Magnus

    2016-06-01

    The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Usability and Accessibility of eBay by Screen Reader

    NASA Astrophysics Data System (ADS)

    Buzzi, Maria Claudia; Buzzi, Marina; Leporini, Barbara; Akhter, Fahim

    The evolution of Information and Communication Technology and the rapid growth of the Internet have fuelled a great diffusion of eCommerce websites. Usually these sites have complex layouts crowded with active elements, and thus are difficult to navigate via screen reader. Interactive environments should be properly designed and delivered to everyone, including the blind, who usually use screen readers to interact with their computers. In this paper we investigate the interaction of blind users with eBay, a popular eCommerce website, and discuss how using the W3C Accessible Rich Internet Applications (WAI-ARIA) suite could improve the user experience when navigating via screen reader.

  17. Ubiquitous Accessibility for People with Visual Impairments: Are We There Yet?

    PubMed Central

    Billah, Syed Masum; Ashok, Vikas; Porter, Donald E.; Ramakrishnan, IV

    2017-01-01

    Ubiquitous access is an increasingly common vision of computing, wherein users can interact with any computing device or service from anywhere, at any time. In the era of personal computing, users with visual impairments required special-purpose, assistive technologies, such as screen readers, to interact with computers. This paper investigates whether technologies like screen readers have kept pace with, or have created a barrier to, the trend toward ubiquitous access, with a specific focus on desktop computing as this is still the primary way computers are used in education and employment. Towards that, the paper presents a user study with 21 visually-impaired participants, specifically involving the switching of screen readers within and across different computing platforms, and the use of screen readers in remote access scenarios. Among the findings, the study shows that, even for remote desktop access—an early forerunner of true ubiquitous access—screen readers are too limited, if not unusable. The study also identifies several accessibility needs, such as uniformity of navigational experience across devices, and recommends potential solutions. In summary, assistive technologies have not made the jump into the era of ubiquitous access, and multiple, inconsistent screen readers create new practical problems for users with visual impairments. PMID:28782061

  18. Ubiquitous Accessibility for People with Visual Impairments: Are We There Yet?

    PubMed

    Billah, Syed Masum; Ashok, Vikas; Porter, Donald E; Ramakrishnan, I V

    2017-05-01

    Ubiquitous access is an increasingly common vision of computing, wherein users can interact with any computing device or service from anywhere, at any time. In the era of personal computing, users with visual impairments required special-purpose, assistive technologies, such as screen readers, to interact with computers. This paper investigates whether technologies like screen readers have kept pace with, or have created a barrier to, the trend toward ubiquitous access, with a specific focus on desktop computing as this is still the primary way computers are used in education and employment. Towards that, the paper presents a user study with 21 visually-impaired participants, specifically involving the switching of screen readers within and across different computing platforms, and the use of screen readers in remote access scenarios. Among the findings, the study shows that, even for remote desktop access-an early forerunner of true ubiquitous access-screen readers are too limited, if not unusable. The study also identifies several accessibility needs, such as uniformity of navigational experience across devices, and recommends potential solutions. In summary, assistive technologies have not made the jump into the era of ubiquitous access, and multiple, inconsistent screen readers create new practical problems for users with visual impairments.

  19. Accessibility of Mobile Devices for Visually Impaired Users: An Evaluation of the Screen-Reader VoiceOver.

    PubMed

    Smaradottir, Berglind; Håland, Jarle; Martinez, Santiago

    2017-01-01

    A mobile device's touchscreen allows users to use a choreography of hand gestures to interact with the user interface. A screen reader on a mobile device is designed to support the interaction of visually disabled users while using gestures. This paper presents an evaluation of VoiceOver, a screen reader in Apple Inc. products. The evaluation was a part of the research project "Visually impaired users touching the screen - a user evaluation of assistive technology".

  20. MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses.

    PubMed

    Bokhart, Mark T; Nazari, Milad; Garrard, Kenneth P; Muddiman, David C

    2018-01-01

    A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. Graphical Abstract ᅟ.

  1. Impact of the Thinking Reader[R] Software Program on Grade 6 Reading Vocabulary, Comprehension, Strategies, and Motivation: Final Report. NCEE 2010-4035

    ERIC Educational Resources Information Center

    Drummond, Kathryn; Chinen, Marjorie; Duncan, Teresa Garcia; Miller, H. Ray; Fryer, Lindsay; Zmach, Courtney; Culp, Katherine

    2011-01-01

    "Thinking Reader" is a software program for students in Grades 5-8 that incorporates elements commonly identified in policy reports as being key components of effective adolescent literacy instruction. This evaluation of the impact of "Thinking Reader" use by Grade 6 students focused on two confirmatory research questions about…

  2. Demonstration of Multi- and Single-Reader Sample Size Program for Diagnostic Studies software.

    PubMed

    Hillis, Stephen L; Schartz, Kevin M

    2015-02-01

    The recently released software Multi- and Single-Reader Sample Size Sample Size Program for Diagnostic Studies , written by Kevin Schartz and Stephen Hillis, performs sample size computations for diagnostic reader-performance studies. The program computes the sample size needed to detect a specified difference in a reader performance measure between two modalities, when using the analysis methods initially proposed by Dorfman, Berbaum, and Metz (DBM) and Obuchowski and Rockette (OR), and later unified and improved by Hillis and colleagues. A commonly used reader performance measure is the area under the receiver-operating-characteristic curve. The program can be used with typical common reader-performance measures which can be estimated parametrically or nonparametrically. The program has an easy-to-use step-by-step intuitive interface that walks the user through the entry of the needed information. Features of the software include the following: (1) choice of several study designs; (2) choice of inputs obtained from either OR or DBM analyses; (3) choice of three different inference situations: both readers and cases random, readers fixed and cases random, and readers random and cases fixed; (4) choice of two types of hypotheses: equivalence or noninferiority; (6) choice of two output formats: power for specified case and reader sample sizes, or a listing of case-reader combinations that provide a specified power; (7) choice of single or multi-reader analyses; and (8) functionality in Windows, Mac OS, and Linux.

  3. Paired split-plot designs of multireader multicase studies.

    PubMed

    Chen, Weijie; Gong, Qi; Gallas, Brandon D

    2018-07-01

    The widely used multireader multicase ROC study design for comparing imaging modalities is the fully crossed (FC) design: every reader reads every case of both modalities. We investigate paired split-plot (PSP) designs that may allow for reduced cost and increased flexibility compared with the FC design. In the PSP design, case images from two modalities are read by the same readers, thereby the readings are paired across modalities. However, within each modality, not every reader reads every case. Instead, both the readers and the cases are partitioned into a fixed number of groups and each group of readers reads its own group of cases-a split-plot design. Using a [Formula: see text]-statistic based variance analysis for AUC (i.e., area under the ROC curve), we show analytically that precision can be gained by the PSP design as compared with the FC design with the same number of readers and readings. Equivalently, we show that the PSP design can achieve the same statistical power as the FC design with a reduced number of readings. The trade-off for the increased precision in the PSP design is the cost of collecting a larger number of truth-verified patient cases than the FC design. This means that one can trade-off between different sources of cost and choose a least burdensome design. We provide a validation study to show the iMRMC software can be reliably used for analyzing data from both FC and PSP designs. Finally, we demonstrate the advantages of the PSP design with a reader study comparing full-field digital mammography with screen-film mammography.

  4. Application of thermoluminescence for detection of cascade shower 1: Hardware and software of reader system

    NASA Technical Reports Server (NTRS)

    Akashi, M.; Kawaguchi, S.; Watanabe, Z.; Misaki, A.; Niwa, M.; Okamoto, Y.; Fujinaga, T.; Ichimura, M.; Shibata, T.; Dake, S.

    1985-01-01

    A reader system for the detection of cascade showers via luminescence induced by heating sensitive material (BaSO4:Eu) is developed. The reader system is composed of following six instruments: (1) heater, (2) light guide, (3) image intensifier, (4) CCD camera, (5) image processor, (6) microcomputer. The efficiency of these apparatuses and software application for image analysis is reported.

  5. MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses

    NASA Astrophysics Data System (ADS)

    Bokhart, Mark T.; Nazari, Milad; Garrard, Kenneth P.; Muddiman, David C.

    2018-01-01

    A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. [Figure not available: see fulltext.

  6. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    PubMed

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  7. Non-visual Web Browsing: Beyond Web Accessibility

    PubMed Central

    Ramakrishnan, I.V.; Ashok, Vikas

    2017-01-01

    People with vision impairments typically use screen readers to browse the Web. To facilitate non-visual browsing, web sites must be made accessible to screen readers, i.e., all the visible elements in the web site must be readable by the screen reader. But even if web sites are accessible, screen-reader users may not find them easy to use and/or easy to navigate. For example, they may not be able to locate the desired information without having to listen to a lot of irrelevant contents. These issues go beyond web accessibility and directly impact web usability. Several techniques have been reported in the accessibility literature for making the Web usable for screen reading. This paper is a review of these techniques. Interestingly, the review reveals that understanding the semantics of the web content is the overarching theme that drives these techniques for improving web usability. PMID:29202137

  8. Non-visual Web Browsing: Beyond Web Accessibility.

    PubMed

    Ramakrishnan, I V; Ashok, Vikas; Billah, Syed Masum

    2017-07-01

    People with vision impairments typically use screen readers to browse the Web. To facilitate non-visual browsing, web sites must be made accessible to screen readers, i.e., all the visible elements in the web site must be readable by the screen reader. But even if web sites are accessible, screen-reader users may not find them easy to use and/or easy to navigate. For example, they may not be able to locate the desired information without having to listen to a lot of irrelevant contents. These issues go beyond web accessibility and directly impact web usability. Several techniques have been reported in the accessibility literature for making the Web usable for screen reading. This paper is a review of these techniques. Interestingly, the review reveals that understanding the semantics of the web content is the overarching theme that drives these techniques for improving web usability.

  9. Fractal Analysis of Visual Search Activity for Mass Detection During Mammographic Screening

    DOE PAGES

    Alamudun, Folami T.; Yoon, Hong-Jun; Hudson, Kathy; ...

    2017-02-21

    Purpose: The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. Methods: The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus data for this study. The fractal dimension of the readers’ visual scanning patternsmore » was computed with the Minkowski–Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Results: Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the visual scanning pattern complexity when screening for breast cancer. No higher order effects were found to be significant. Conclusions: Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics.« less

  10. Using an Interactive Singing Software Program: A Comparative Study of Struggling Middle School Readers

    ERIC Educational Resources Information Center

    Biggs, Marie C.; Homan, Susan P.; Dedrick, Robert; Minick, Vanessa; Rasinski, Timothy

    2008-01-01

    Software that teaches users to sing in tune and in rhythm while providing real-time pitch tracking was used in a study of struggling middle school readers. The software, Carry-a-Tune (CAT) was originally developed to improve singing; however, since it involves a repeated reading format, we used it to determine its effect on comprehension and…

  11. Ultra-low current biosensor output detection using portable electronic reader

    NASA Astrophysics Data System (ADS)

    Yahaya, N. A. N.; Rajapaksha, R. D. A. A.; Uda, M. N. Afnan; Hashim, U.

    2017-09-01

    Generally, the electrical biosensor usually shows extremely low current signal output around pico ampere to microampere range. In this research, electronic reader with amplifier has been demonstrated to detect ultra low current via the biosensor. The operational amplifier Burr-Brown OPA 128 and Arduino Uno board were used to construct the portable electronic reader. There are two cascaded inverting amplifier were used to detect ultra low current through the biosensor from pico amperes (pA) to nano amperes ranges (nA). A small known input current was form by applying variable voltage between 0.1V to 5.0V across a 5GΩ high resistor to check the amplifier circuit. The amplifier operation was measured with the high impedance current source and has been compared with the theoretical measurement. The Arduino Uno was used to convert the analog signal to digital signal and process the data to display on reader screen. In this project, Proteus software was used to design and test the circuit. Then it was implemented together with Arduino Uno board. Arduino board was programmed using C programming language to make whole circuit communicate each order. The current was measured then it shows a small difference values compared to theoretical values, which is approximately 14pA.

  12. How quickly do breast screeners learn their skills?

    NASA Astrophysics Data System (ADS)

    Nevisi, Hossein; Dong, Leng; Chen, Yan; Gale, Alastair G.

    2017-03-01

    The UK's Breast Screening Programme is 27 years old and many experienced breast radiologists are now retiring, coupled with an influx of new screening personnel. It is important to the ongoing Programme that new mammography readers are quickly up to the skill level of experienced readers. This raises the question of how quickly the necessary cancer detection skills are learnt. All breast screening radiologists in the UK read educational training sets of challenging FFDM images (the PERFORMS® scheme) yearly to maintain and improve their performance in real life screening. Data were examined from the PERFORMS® annual scheme for 54 new screeners, 55 screeners who have been screening for one year and also for more experienced screeners (597 screeners). Not surprisingly, significant differences in cancer detection rate were found between new readers and both of the other groups. Additionally, the performance of 48 new readers who have now been screening for about a year and have taken part twice in the PERFORMS® scheme were further examined where again a significant difference in cancer detection was found. These data imply that cancer detection skills are learnt quickly in the first year of screening. Information was also examined concerning the volume of cases participants read and other factors.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alamudun, Folami T.; Yoon, Hong-Jun; Hudson, Kathy

    Purpose: The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. Methods: The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus data for this study. The fractal dimension of the readers’ visual scanning patternsmore » was computed with the Minkowski–Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Results: Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the visual scanning pattern complexity when screening for breast cancer. No higher order effects were found to be significant. Conclusions: Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics.« less

  14. Impact of Different Study Populations on Reader Behavior and Performance Metrics: Initial Results

    PubMed Central

    Gallas, Brandon D.; Pisano, Etta; Cole, Elodia; Myers, Kyle

    2017-01-01

    The FDA recently completed a study on design methodologies surrounding the Validation of Imaging Premarket Evaluation and Regulation called VIPER. VIPER consisted of five large reader sub-studies to compare the impact of different study populations on reader behavior as seen by sensitivity, specificity, and AUC, the area under the ROC curve (receiver operating characteristic curve). The study investigated different prevalence levels and two kinds of sampling of non-cancer patients: a screening population and a challenge population. The VIPER study compared full-field digital mammography (FFDM) to screen-film mammography (SFM) for women with heterogeneously dense or extremely dense breasts. All cases and corresponding images were sampled from Digital Mammographic Imaging Screening Trial (DMIST) archives. There were 20 readers (American Board Certified radiologists) for each sub-study, and instead of every reader reading every case (fully-crossed study), readers and cases were split into groups to reduce reader workload and the total number of observations (split-plot study). For data collection, readers first decided whether or not they would recall a patient. Following that decision, they provided an ROC score for how close or far that patient was from the recall decision threshold. Performance results for FFDM show that as prevalence increases to 50%, there is a moderate increase in sensitivity and decrease in specificity, whereas AUC is mainly flat. Regarding precision, the statistical efficiency (ratio of variances) of sensitivity and specificity relative to AUC are 0.66 at best and decrease with prevalence. Analyses comparing modalities and the study populations (screening vs. challenge) are still ongoing. PMID:28845078

  15. Computerized trainings in four groups of struggling readers: Specific effects on word reading and comprehension.

    PubMed

    Potocki, Anna; Magnan, Annie; Ecalle, Jean

    2015-01-01

    Four groups of poor readers were identified among a population of students with learning disabilities attending a special class in secondary school: normal readers; specific poor decoders; specific poor comprehenders, and general poor readers (deficits in both decoding and comprehension). These students were then trained with a software program designed to encourage either their word decoding skills or their text comprehension skills. After 5 weeks of training, we observed that the students experiencing word reading deficits and trained with the decoding software improved primarily in the reading fluency task while those exhibiting comprehension deficits and trained with the comprehension software showed improved performance in listening and reading comprehension. But interestingly, the latter software also led to improved performance on the word recognition task. This result suggests that, for these students, training interventions focused at the text level and its comprehension might be more beneficial for reading in general (i.e., for the two components of reading) than word-level decoding trainings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Retinal Imaging Techniques for Diabetic Retinopathy Screening

    PubMed Central

    Goh, James Kang Hao; Cheung, Carol Y.; Sim, Shaun Sebastian; Tan, Pok Chien; Tan, Gavin Siew Wei; Wong, Tien Yin

    2016-01-01

    Due to the increasing prevalence of diabetes mellitus, demand for diabetic retinopathy (DR) screening platforms is steeply increasing. Early detection and treatment of DR are key public health interventions that can greatly reduce the likelihood of vision loss. Current DR screening programs typically employ retinal fundus photography, which relies on skilled readers for manual DR assessment. However, this is labor-intensive and suffers from inconsistency across sites. Hence, there has been a recent proliferation of automated retinal image analysis software that may potentially alleviate this burden cost-effectively. Furthermore, current screening programs based on 2-dimensional fundus photography do not effectively screen for diabetic macular edema (DME). Optical coherence tomography is becoming increasingly recognized as the reference standard for DME assessment and can potentially provide a cost-effective solution for improving DME detection in large-scale DR screening programs. Current screening techniques are also unable to image the peripheral retina and require pharmacological pupil dilation; ultra-widefield imaging and confocal scanning laser ophthalmoscopy, which address these drawbacks, possess great potential. In this review, we summarize the current DR screening methods using various retinal imaging techniques, and also outline future possibilities. Advances in retinal imaging techniques can potentially transform the management of patients with diabetes, providing savings in health care costs and resources. PMID:26830491

  17. Retinal Imaging Techniques for Diabetic Retinopathy Screening.

    PubMed

    Goh, James Kang Hao; Cheung, Carol Y; Sim, Shaun Sebastian; Tan, Pok Chien; Tan, Gavin Siew Wei; Wong, Tien Yin

    2016-02-01

    Due to the increasing prevalence of diabetes mellitus, demand for diabetic retinopathy (DR) screening platforms is steeply increasing. Early detection and treatment of DR are key public health interventions that can greatly reduce the likelihood of vision loss. Current DR screening programs typically employ retinal fundus photography, which relies on skilled readers for manual DR assessment. However, this is labor-intensive and suffers from inconsistency across sites. Hence, there has been a recent proliferation of automated retinal image analysis software that may potentially alleviate this burden cost-effectively. Furthermore, current screening programs based on 2-dimensional fundus photography do not effectively screen for diabetic macular edema (DME). Optical coherence tomography is becoming increasingly recognized as the reference standard for DME assessment and can potentially provide a cost-effective solution for improving DME detection in large-scale DR screening programs. Current screening techniques are also unable to image the peripheral retina and require pharmacological pupil dilation; ultra-widefield imaging and confocal scanning laser ophthalmoscopy, which address these drawbacks, possess great potential. In this review, we summarize the current DR screening methods using various retinal imaging techniques, and also outline future possibilities. Advances in retinal imaging techniques can potentially transform the management of patients with diabetes, providing savings in health care costs and resources. © 2016 Diabetes Technology Society.

  18. Standalone medical device software: The evolving regulatory framework.

    PubMed

    McCarthy, Avril D; Lawford, Patricia V

    2014-01-01

    The paper provides an introduction to the regulatory landscape affecting a particular category of medical technology, namely standalone software-sometimes referred to as 'software as a medical device'. To aid the reader's comprehension of an often complex area, six case studies are outlined and discussed before the paper continues to provide detail of how software with a medical purpose in its own right can potentially be classified as a medical device. The reader is provided an appreciation of how to go about classifying such software and references to support the developer new to the field in locating detailed regulatory support documents and contact points for advice.

  19. Shapelet analysis of pupil dilation for modeling visuo-cognitive behavior in screening mammography

    NASA Astrophysics Data System (ADS)

    Alamudun, Folami; Yoon, Hong-Jun; Hammond, Tracy; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia

    2016-03-01

    Our objective is to improve understanding of visuo-cognitive behavior in screening mammography under clinically equivalent experimental conditions. To this end, we examined pupillometric data, acquired using a head-mounted eye-tracking device, from 10 image readers (three breast-imaging radiologists and seven Radiology residents), and their corresponding diagnostic decisions for 100 screening mammograms. The corpus of mammograms comprised cases of varied pathology and breast parenchymal density. We investigated the relationship between pupillometric fluctuations, experienced by an image reader during mammographic screening, indicative of changes in mental workload, the pathological characteristics of a mammographic case, and the image readers' diagnostic decision and overall task performance. To answer these questions, we extract features from pupillometric data, and additionally applied time series shapelet analysis to extract discriminative patterns in changes in pupil dilation. Our results show that pupillometric measures are adequate predictors of mammographic case pathology, and image readers' diagnostic decision and performance with an average accuracy of 80%.

  20. Orthographic learning and the role of text-to-speech software in Dutch disabled readers.

    PubMed

    Staels, Eva; Van den Broeck, Wim

    2015-01-01

    In this study, we examined whether orthographic learning can be demonstrated in disabled readers learning to read in a transparent orthography (Dutch). In addition, we tested the effect of the use of text-to-speech software, a new form of direct instruction, on orthographic learning. Both research goals were investigated by replicating Share's self-teaching paradigm. A total of 65 disabled Dutch readers were asked to read eight stories containing embedded homophonic pseudoword targets (e.g., Blot/Blod), with or without the support of text-to-speech software. The amount of orthographic learning was assessed 3 or 7 days later by three measures of orthographic learning. First, the results supported the presence of orthographic learning during independent silent reading by demonstrating that target spellings were correctly identified more often, named more quickly, and spelled more accurately than their homophone foils. Our results support the hypothesis that all readers, even poor readers of transparent orthographies, are capable of developing word-specific knowledge. Second, a negative effect of text-to-speech software on orthographic learning was demonstrated in this study. This negative effect was interpreted as the consequence of passively listening to the auditory presentation of the text. We clarify how these results can be interpreted within current theoretical accounts of orthographic learning and briefly discuss implications for remedial interventions. © Hammill Institute on Disabilities 2013.

  1. The classification of normal screening mammograms

    NASA Astrophysics Data System (ADS)

    Ang, Zoey Z. Y.; Rawashdeh, Mohammad A.; Heard, Robert; Brennan, Patrick C.; Lee, Warwick; Lewis, Sarah J.

    2016-03-01

    Rationale and objectives: To understand how breast screen readers classify the difficulty of normal screening mammograms using common lexicon describing normal appearances. Cases were also assessed on their suitability for a single reader strategy. Materials and Methods: 15 breast readers were asked to interpret a test set of 29 normal screening mammogram cases and classify them by rating the difficulty of the case on a five-point Likert scale, identifying the salient features and assessing their suitability for single reading. Using the False Positive Fractions from a previous study, the 29 cases were classified into 10 "low", 10 "medium" and nine "high" difficulties. Data was analyzed with descriptive statistics. Spearman's correlation was used to test the strength of association between the difficulty of the cases and the readers' recommendation for single reading strategy. Results: The ratings from readers in this study corresponded to the known difficulty level of cases for the 'low' and 'high' difficulty cases. Uniform ductal pattern and density, symmetrical mammographic features and the absence of micro-calcifications were the main reasons associated with 'low' difficulty cases. The 'high' difficulty cases were described as having `dense breasts'. There was a statistically significant negative correlation between the difficulty of the cases and readers' recommendation for single reading (r = -0.475, P = 0.009). Conclusion: The findings demonstrated potential relationships between certain mammographic features and the difficulty for readers to classify mammograms as 'normal'. The standard Australian practice of double reading was deemed more suitable for most cases. There was an inverse moderate association between the difficulty of the cases and the recommendations for single reading.

  2. Orthographic Learning and the Role of Text-to-Speech Software in Dutch Disabled Readers

    ERIC Educational Resources Information Center

    Staels, Eva; Van den Broeck, Wim

    2015-01-01

    In this study, we examined whether orthographic learning can be demonstrated in disabled readers learning to read in a transparent orthography (Dutch). In addition, we tested the effect of the use of text-to-speech software, a new form of direct instruction, on orthographic learning. Both research goals were investigated by replicating Share's…

  3. The Accelerated Reader: An Analysis of the Software's Strengths and Weaknesses and How It Can Be Used to Its Best Potential.

    ERIC Educational Resources Information Center

    Poock, Melanie M.

    1998-01-01

    Describes Accelerated Reader (AR), a computer software program that promotes reading; discusses AR hardware requirements; explains how it is used for book selection and testing in schools; assesses the program's strengths and weaknesses; and describes how Grant and Madison Elementary Schools (Muscatine, Iowa) have used the program effectively.…

  4. A Comparative Study on Java Technologies for Focus and Cursor Handling in Accessible Dynamic Interactions.

    PubMed

    Jitngernmadan, Prajaks; Miesenberger, Klaus

    2015-01-01

    For an interactive application, supporting and guiding the user in fulfilling tasks is most important. The behavior of the application that will guide users through the procedures until they finish the task has to be designed intuitively and well guiding, especially if the users has only restricted or no access to the visual and spatial arrangement on the screen. Therefore, the focus/cursor management plays an important role for orientation and navigating through the interaction. In the frame of ongoing research on a software tool supporting blind people in more efficiently doing mathematical calculations, we researched how Java technologies support implementing an accessible Graphical User Interface (GUI) with an additional focus on usable accessibility in terms of guiding blind users through the process of solving mathematical calculations. We used Java Swing [1] and Eclipse SWT [2] APIs for creating a series of prototypes. We tested a) accessibility and usability of the prototypes for blind people when using screen reader software and refreshable Braille display and b) the implementation support to developers provided by both technologies. It turned out that Eclipse SWT API delivered best results under Windows operating system.

  5. Enhanced Recognition of Written Words and Enjoyment of Reading in Struggling Beginner Readers through Whole-Word Multimedia Software

    ERIC Educational Resources Information Center

    Karemaker, Arjette; Pitchford, Nicola J.; O'Malley, Claire

    2010-01-01

    The effectiveness of a reading intervention using the whole-word multimedia software "Oxford Reading Tree (ORT) for Clicker" was compared to a reading intervention using traditional ORT Big Books. Developing literacy skills and attitudes towards learning to read were assessed in a group of 17 struggling beginner readers aged 5-6 years. Each child…

  6. Consensus review of discordant findings maximizes cancer detection rate in double-reader screening mammography: Irish National Breast Screening Program experience.

    PubMed

    Shaw, Colette M; Flanagan, Fidema L; Fenlon, Helen M; McNicholas, Michelle M

    2009-02-01

    To assesses consensus review of discordant screening mammography findings in terms of its sensitivity, safety, and effect on overall performance in the first 6 years of operation of the Irish National Breast Screening Program (NBSP). Women who participated in the Irish NBSP gave written informed consent for use of their data for auditing purposes. Local ethics committee approval was obtained. The study population consisted of women who participated in the Irish NBSP and underwent initial screening mammography at one of the two screening centers serving the eastern part of Ireland between 2000 and 2005. Independent double reading of mammograms was performed. When the readers disagreed regarding referral, the case was reviewed by a consensus panel. Of the 128 569 screenings performed, 1335 (1%) were discussed by consensus. Of the 1335 cases discussed by consensus, 606 (45.39%) were recalled for further assessment. This resulted in an overall recall rate of 4.41%. In those recalled to assessment, 71 cases of malignant disease were diagnosed (ductal carcinoma in situ, n = 24; invasive cancer, n = 47). The remaining 729 patients were returned to biennial screening. Of these 729 patients, seven had false-negative findings that were identified in the subsequent screening round. Use of the highest reader recall method, in which a patient is recalled if her findings are deemed abnormal by either reader, could potentially increase the cancer detection rate by 0.6 per 1000 women screened but would increase the recall rate by 12.69% and the number of false-positive findings by 15.37%. The consensus panel identified 71 (7.33%) of 968 cancers diagnosed. Consensus review substantially reduced the number of cases recalled and was associated with a low false-negative rate.

  7. Diagnostic performance of an automated analysis software for the diagnosis of Alzheimer’s dementia with 18F FDG PET

    PubMed Central

    Partovi, Sasan; Yuh, Roger; Pirozzi, Sara; Lu, Ziang; Couturier, Spencer; Grosse, Ulrich; Schluchter, Mark D; Nelson, Aaron; Jones, Robert; O’Donnell, James K; Faulhaber, Peter

    2017-01-01

    The objective of this study was to assess the ability of a quantitative software-aided approach to improve the diagnostic accuracy of 18F FDG PET for Alzheimer’s dementia over visual analysis alone. Twenty normal subjects (M:F-12:8; mean age 80.6 years) and twenty mild AD subjects (M:F-12:8; mean age 70.6 years) with 18F FDG PET scans were obtained from the ADNI database. Three blinded readers interpreted these PET images first using a visual qualitative approach and then using a quantitative software-aided approach. Images were classified on two five-point scales based on normal/abnormal (1-definitely normal; 5-definitely abnormal) and presence of AD (1-definitely not AD; 5-definitely AD). Diagnostic sensitivity, specificity, and accuracy for both approaches were compared based on the aforementioned scales. The sensitivity, specificity, and accuracy for the normal vs. abnormal readings of all readers combined were higher when comparing the software-aided vs. visual approach (sensitivity 0.93 vs. 0.83 P = 0.0466; specificity 0.85 vs. 0.60 P = 0.0005; accuracy 0.89 vs. 0.72 P<0.0001). The specificity and accuracy for absence vs. presence of AD of all readers combined were higher when comparing the software-aided vs. visual approach (specificity 0.90 vs. 0.70 P = 0.0008; accuracy 0.81 vs. 0.72 P = 0.0356). Sensitivities of the software-aided and visual approaches did not differ significantly (0.72 vs. 0.73 P = 0.74). The quantitative software-aided approach appears to improve the performance of 18F FDG PET for the diagnosis of mild AD. It may be helpful for experienced 18F FDG PET readers analyzing challenging cases. PMID:28123864

  8. The time course of cancer detection performance

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, Sian; Clarke, Aileen; Wallis, Matthew; Wheaton, Margot; Duncan, Alison; Gale, Alastair G.

    2011-03-01

    The purpose of this study was to measure how mammography readers' performance varies with time of day and time spent reading. This was investigated in screening practice and when reading an enriched case set. In screening practice records of time and date that each case was read, along with outcome (whether the woman was recalled for further tests, and biopsy results where performed) was extracted from records from one breast screening centre in UK (4 readers). Patterns of performance with time spent reading was also measured using an enriched test set (160 cases, 41% malignant, read three times by eight radiologists). Recall rates varied with time of day, with different patterns for each reader. Recall rates decreased as the reading session progressed both when reading the enriched test set and in screening practice. Further work is needed to expand this work to a greater number of breast screening centres, and to determine whether these patterns of performance over time can be used to optimize overall performance.

  9. Benefits of Structured After-School Literacy Tutoring by University Students for Struggling Elementary Readers

    ERIC Educational Resources Information Center

    Lindo, Endia J.; Weiser, Beverly; Cheatham, Jennifer P.; Allor, Jill H.

    2018-01-01

    This study examines the effectiveness of minimally trained tutors providing a highly structured tutoring intervention for struggling readers. We screened students in Grades K-6 for participation in an after-school tutoring program. We randomly assigned those students not meeting the benchmark on a reading screening measure to either a tutoring…

  10. Impact of different study populations on reader behavior and performance metrics: initial results

    NASA Astrophysics Data System (ADS)

    Gallas, Brandon D.; Pisano, Etta; Cole, Elodia; Myers, Kyle

    2017-03-01

    The FDA recently completed a study on design methodologies surrounding the Validation of Imaging Premarket Evaluation and Regulation called VIPER. VIPER consisted of five large reader sub-studies to compare the impact of different study populations on reader behavior as seen by sensitivity, specificity, and AUC, the area under the ROC curve (receiver operating characteristic curve). The study investigated different prevalence levels and two kinds of sampling of non-cancer patients: a screening population and a challenge population. The VIPER study compared full-field digital mammography (FFDM) to screenfilm mammography (SFM) for women with heterogeneously dense or extremely dense breasts. All cases and corresponding images were sampled from Digital Mammographic Imaging Screening Trial (DMIST) archives. There were 20 readers (American Board Certified radiologists) for each sub-study, and instead of every reader reading every case (fully-crossed study), readers and cases were split into groups to reduce reader workload and the total number of observations (split-plot study). For data collection, readers first decided whether or not they would recall a patient. Following that decision, they provided an ROC score for how close or far that patient was from the recall decision threshold. Performance results for FFDM show that as prevalence increases to 50%, there is a moderate increase in sensitivity and decrease in specificity, whereas AUC is mainly flat. Regarding precision, the statistical efficiency (ratio of variances) of sensitivity and specificity relative to AUC are 0.66 at best and decrease with prevalence. Analyses comparing modalities and the study populations (screening vs. challenge) are still ongoing.

  11. Monoscopic versus stereoscopic photography in screening for clinically significant macular edema.

    PubMed

    Welty, Christopher J; Agarwal, Anita; Merin, Lawrence M; Chomsky, Amy

    2006-01-01

    The purpose of the study was to determine whether monoscopic photography could serve as an accurate tool when used to screen for clinically significant macular edema. In a masked randomized fashion, two readers evaluated monoscopic and stereoscopic retinal photographs of 100 eyes. The photographs were evaluated first individually for probable clinically significant macular edema based on the Early Treatment Diabetic Retinopathy Study criteria and then as stereoscopic pairs. Graders were evaluated for sensitivity and specificity individually and in combination. Individually, reader one had a sensitivity of 0.93 and a specificity of 0.77, and reader two had a sensitivity of 0.88 and a specificity of 0.94. In combination, the readers had a sensitivity of 0.91 and a specificity of 0.86. They correlated on 0.76 of the stereoscopic readings and 0.92 of the monoscopic readings. These results indicate that the use of monoscopic retinal photography may be an accurate screening tool for clinically significant macular edema.

  12. Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program: validation of results in a large multireader, multicase study.

    PubMed

    Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I

    2016-12-01

    Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience. All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no CESM experience but were experienced breast radiologists, and three were residents. All readers provided a BI-RADS score for the low-energy CESM images first, after which the score could be adjusted when viewing the entire CESM exam. BI-RADS 1-3 were considered benign and BI-RADS 4-5 malignant. With this cutoff, we calculated sensitivity, specificity and area under the ROC curve. CESM increased diagnostic accuracy in all readers. The performance for all readers using CESM was: sensitivity 96.9 % (+3.9 %), specificity 69.7 % (+33.8 %) and area under the ROC curve 0.833 (+0.188). CESM is superior to conventional mammography, with excellent problem-solving capabilities in women referred from the breast cancer screening program. Previous results were confirmed even in a larger panel of readers with varying CESM experience. • CESM is consistently superior to conventional mammography • CESM increases diagnostic accuracy regardless of a reader's experience • CESM is an excellent problem-solving tool in recalls from screening programs.

  13. Editing Wikipedia content by screen reader: easier interaction with the Accessible Rich Internet Applications suite.

    PubMed

    Buzzi, Marina; Leporini, Barbara

    2009-07-01

    This study aims to improve Wikipedia usability for the blind and promote the application of standards relating to Web accessibility and usability. First, accessibility and usability of Wikipedia home, search result and edit pages are analysed using the JAWS screen reader; next, suggestions for improving interaction are proposed and a new Wikipedia editing interface built. Most of the improvements were obtained using the Accessible Rich Internet Applications (WAI-ARIA) suite, developed by the World Wide Web Consortium (W3C) within the framework of the Web Accessibility Initiative (WAI). Last, a scenario of use compares interaction of blind people with the original and the modified interfaces. Our study highlights that although all contents are accessible via screen reader, usability issues exist due to the user's difficulties when interacting with the interface. The scenario of use shows how building an editing interface with the W3C WAI-ARIA suite eliminates many obstacles that can prevent blind users from actively contributing to Wikipedia. The modified Wikipedia editing page is simpler to use via a screen reader than the original one because ARIA ensures a page overview, rapid navigation, and total control of what is happening in the interface.

  14. Access to digital library databases in higher education: design problems and infrastructural gaps.

    PubMed

    Oswal, Sushil K

    2014-01-01

    After defining accessibility and usability, the author offers a broad survey of the research studies on digital content databases which have thus far primarily depended on data drawn from studies conducted by sighted researchers with non-disabled users employing screen readers and low vision devices. This article aims at producing a detailed description of the difficulties confronted by blind screen reader users with online library databases which now hold most of the academic, peer-reviewed journal and periodical content essential for research and teaching in higher education. The approach taken here is borrowed from descriptive ethnography which allows the author to create a complete picture of the accessibility and usability problems faced by an experienced academic user of digital library databases and screen readers. The author provides a detailed analysis of the different aspects of accessibility issues in digital databases under several headers with a special focus on full-text PDF files. The author emphasizes that long-term studies with actual, blind screen reader users employing both qualitative and computerized research tools can yield meaningful data for the designers and developers to improve these databases to a level that they begin to provide an equal access to the blind.

  15. Readability, Suitability and Health Content Assessment of Cancer Screening Announcements in Municipal Newspapers in Japan.

    PubMed

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Hiroko; Kiuchi, Takahiro

    2015-01-01

    The objective of this study was to assess the readability, suitability, and health content of cancer screening information in municipal newspapers in Japan. Suitability Assessment of Materials (SAM) and the framework of Health Belief Model (HBM) were used for assessment of municipal newspapers that were published in central Tokyo (23 wards) from January to December 2013. The mean domain SAM scores of content, literacy demand, and layout/typography were considered superior. The SAM scores of interaction with readers, an indication of the models of desirable actions, and elaboration to enhance readers' self-efficacy were low. According to the HBM coding, messages of medical/clinical severity, of social severity, of social benefits, and of barriers of fear were scarce. The articles were generally well written and suitable. However, learning stimulation/motivation was scarce and the HBM constructs were not fully addressed. Articles can be improved to motivate readers to obtain cancer screening by increasing interaction with readers, introducing models of desirable actions and devices to raise readers' self-efficacy, and providing statements of perceived barriers of fear for pain and time constraints, perceived severity, and social benefits and losses.

  16. Breaking off Engagement: Readers' Disengagement as a Function of Reader and Text Characteristics

    ERIC Educational Resources Information Center

    Goedecke, Patricia J.; Dong, Daqi; Shi, Genghu; Feng, Shi; Risko, Evan; Olney, Andrew M.; D'Mello, Sidney K.; Graesser, Arthur C.

    2015-01-01

    Engagement during reading can be measured by the amount of time readers invest in the reading process. It is hypothesized that disengagement is marked by a decrease in time investment as compared with the demands made on the reader by the text. In this study, self-paced reading times for screens of text were predicted by a text complexity score…

  17. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.

    PubMed

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia.

  18. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia

    PubMed Central

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia. PMID:28800632

  19. An evaluation of automated chest radiography reading software for tuberculosis screening among public- and private-sector patients.

    PubMed

    Rahman, Md Toufiq; Codlin, Andrew J; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera; Creswell, Jacob

    2017-05-01

    Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert).Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receiver operating characteristic curve (AUC), and calculated the potential Xpert tests saved.A total of 18 036 individuals were enrolled. TB prevalence by Xpert was 15%. The radiologist graded 49% of CXRs as abnormal, resulting in 91% sensitivity and 58% specificity. At a similar sensitivity, CAR had a lower specificity (41%), saving fewer (36%) Xpert tests. The AUC for CAR was 0.74 (95% CI 0.73-0.75). CAR performance declined with increasing age. The radiologist grading was superior across all sub-analyses.Using CAR can save Xpert tests, but the radiologist's specificity was superior. Differentiated CAR thresholds may be required for different populations. Access to, and costs of, human readers must be considered when deciding to use CAR software. More studies are needed to evaluate CAR using different screening approaches. Copyright ©ERS 2017.

  20. An evaluation of automated chest radiography reading software for tuberculosis screening among public- and private-sector patients

    PubMed Central

    Rahman, Md Toufiq; Codlin, Andrew J.; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera

    2017-01-01

    Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert). Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receiver operating characteristic curve (AUC), and calculated the potential Xpert tests saved. A total of 18 036 individuals were enrolled. TB prevalence by Xpert was 15%. The radiologist graded 49% of CXRs as abnormal, resulting in 91% sensitivity and 58% specificity. At a similar sensitivity, CAR had a lower specificity (41%), saving fewer (36%) Xpert tests. The AUC for CAR was 0.74 (95% CI 0.73–0.75). CAR performance declined with increasing age. The radiologist grading was superior across all sub-analyses. Using CAR can save Xpert tests, but the radiologist's specificity was superior. Differentiated CAR thresholds may be required for different populations. Access to, and costs of, human readers must be considered when deciding to use CAR software. More studies are needed to evaluate CAR using different screening approaches. PMID:28529202

  1. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  2. Effect of Two Different Screen Readers' Programs on Developing Using the Internet Skills of Blind Middle School Students

    ERIC Educational Resources Information Center

    Mostafa, Akram Fathy; Bin Mta'en, Isa Bin Yahya

    2017-01-01

    Research aims to know the effect of two different designs of screen readers' programs on using the internet skills of blind middle school students, and the research sample consisted of (8) students from El-thoghr middle school students (Fousol El-Noor)-Jeddah where the student has been divided into two experimental groups each of (4) students. To…

  3. Identification of a small-molecule ligand of the epigenetic reader protein Spindlin1 via a versatile screening platform

    PubMed Central

    Wagner, Tobias; Greschik, Holger; Burgahn, Teresa; Schmidtkunz, Karin; Schott, Anne-Kathrin; McMillan, Joel; Baranauskienė, Lina; Xiong, Yan; Fedorov, Oleg; Jin, Jian; Oppermann, Udo; Matulis, Daumantas; Schüle, Roland; Jung, Manfred

    2016-01-01

    Epigenetic modifications of histone tails play an essential role in the regulation of eukaryotic transcription. Writer and eraser enzymes establish and maintain the epigenetic code by creating or removing posttranslational marks. Specific binding proteins, called readers, recognize the modifications and mediate epigenetic signalling. Here, we present a versatile assay platform for the investigation of the interaction between methyl lysine readers and their ligands. This can be utilized for the screening of small-molecule inhibitors of such protein–protein interactions and the detailed characterization of the inhibition. Our platform is constructed in a modular way consisting of orthogonal in vitro binding assays for ligand screening and verification of initial hits and biophysical, label-free techniques for further kinetic characterization of confirmed ligands. A stability assay for the investigation of target engagement in a cellular context complements the platform. We applied the complete evaluation chain to the Tudor domain containing protein Spindlin1 and established the in vitro test systems for the double Tudor domain of the histone demethylase JMJD2C. We finally conducted an exploratory screen for inhibitors of the interaction between Spindlin1 and H3K4me3 and identified A366 as the first nanomolar small-molecule ligand of a Tudor domain containing methyl lysine reader. PMID:26893353

  4. Playing with Plug-ins

    ERIC Educational Resources Information Center

    Thompson, Douglas E.

    2013-01-01

    In today's complex music software packages, many features can remain unexplored and unused. Software plug-ins--available in most every music software package, yet easily overlooked in the software's basic operations--are one such feature. In this article, I introduce readers to plug-ins and offer tips for purchasing plug-ins I have…

  5. Bar-Code System for a Microbiological Laboratory

    NASA Technical Reports Server (NTRS)

    Law, Jennifer; Kirschner, Larry

    2007-01-01

    A bar-code system has been assembled for a microbiological laboratory that must examine a large number of samples. The system includes a commercial bar-code reader, computer hardware and software components, plus custom-designed database software. The software generates a user-friendly, menu-driven interface.

  6. An experience of qualified preventive screening: shiraz smart screening software.

    PubMed

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  7. Cancer Cases from ACRIN Digital Mammographic Imaging Screening Trial: Radiologist Analysis with Use of a Logistic Regression Model1

    PubMed Central

    Pisano, Etta D.; Acharyya, Suddhasatta; Cole, Elodia B.; Marques, Helga S.; Yaffe, Martin J.; Blevins, Meredith; Conant, Emily F.; Hendrick, R. Edward; Baum, Janet K.; Fajardo, Laurie L.; Jong, Roberta A.; Koomen, Marcia A.; Kuzmiak, Cherie M.; Lee, Yeonhee; Pavic, Dag; Yoon, Sora C.; Padungchaichote, Wittaya; Gatsonis, Constantine

    2009-01-01

    Purpose: To determine which factors contributed to the Digital Mammographic Imaging Screening Trial (DMIST) cancer detection results. Materials and Methods: This project was HIPAA compliant and institutional review board approved. Seven radiologist readers reviewed the film hard-copy (screen-film) and digital mammograms in DMIST cancer cases and assessed the factors that contributed to lesion visibility on both types of images. Two multinomial logistic regression models were used to analyze the combined and condensed visibility ratings assigned by the readers to the paired digital and screen-film images. Results: Readers most frequently attributed differences in DMIST cancer visibility to variations in image contrast—not differences in positioning or compression—between digital and screen-film mammography. The odds of a cancer being more visible on a digital mammogram—rather than being equally visible on digital and screen-film mammograms—were significantly greater for women with dense breasts than for women with nondense breasts, even with the data adjusted for patient age, lesion type, and mammography system (odds ratio, 2.28; P < .0001). The odds of a cancer being more visible at digital mammography—rather than being equally visible at digital and screen-film mammography—were significantly greater for lesions imaged with the General Electric digital mammography system than for lesions imaged with the Fischer (P = .0070) and Fuji (P = .0070) devices. Conclusion: The significantly better diagnostic accuracy of digital mammography, as compared with screen-film mammography, in women with dense breasts demonstrated in the DMIST was most likely attributable to differences in image contrast, which were most likely due to the inherent system performance improvements that are available with digital mammography. The authors conclude that the DMIST results were attributable primarily to differences in the display and acquisition characteristics of the mammography devices rather than to reader variability. PMID:19703878

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Houssami, Nehmat

    This study aimed to evaluate the accuracy of radiographers’ screen-reading mammograms. Currently, radiologist workforce shortages may be compromising the BreastScreen Australia screening program goal to detect early breast cancer. The solution to a similar problem in the United Kingdom has successfully encouraged radiographers to take on the role as one of two screen-readers. Prior to consideration of this strategy in Australia, educational and experiential differences between radiographers in the United Kingdom and Australia emphasise the need for an investigation of Australian radiographers’ screen-reading accuracy. Ten radiographers employed by the Westmead Breast Cancer Institute with a range of radiographic (median =more » 28 years), mammographic (median = 13 years) and BreastScreen (median = 8 years) experience were recruited to blindly and independently screen-read an image test set of 500 mammograms, without formal training. The radiographers indicated the presence of an abnormality using BI-RADS®. Accuracy was determined by comparison with the gold standard of known outcomes of pathology results, interval matching and client 6-year follow-up. Individual sensitivity and specificity levels ranged between 76.0% and 92.0%, and 74.8% and 96.2% respectively. Pooled screen-reader accuracy across the radiographers estimated sensitivity as 82.2% and specificity as 89.5%. Areas under the reading operating characteristic curve ranged between 0.842 and 0.923. This sample of radiographers in an Australian setting have adequate accuracy levels when screen-reading mammograms. It is expected that with formal screen-reading training, accuracy levels will improve, and with support, radiographers have the potential to be one of the two screen-readers in the BreastScreen Australia program, contributing to timeliness and improved program outcomes.« less

  9. Acute Brain Imaging in Children: Can MRI Replace CT as a Screening Tool?

    PubMed

    Wagner, Matthias W; Kontzialis, Marinos; Seeburg, Daniel; Stern, Steven E; Oshmyansky, Alexander; Poretti, Andrea; Huisman, Thierry A G M

    2016-01-01

    To determine if axial T2-weighted imaging can serve as screening tool for pediatric brain imaging. We retrospectively evaluated consecutive brain magnetic resonance imaging (MRI) data of 161 children (74 girls) with a mean age of 7.44 ± 5.71 years. Standard of reference was the final report of neuroradiology attendings. Three readers with different levels of experience were blinded for clinical diagnoses and study indications. First, readers studied only the axial T2-weighted screening sequence. Second, they studied all available anatomical and functional MRI sequences as performed per standard protocol for each clinical indication. The readings were classified as normal or abnormal. Sensitivity and specificity were measured. Axial T2 screening yielded a sensitivity of 77-88% and a specificity of 92%. The full studies/data sets had a sensitivity of 89-95% and a specificity of 86-93%. Nineteen of 167 studies were acquired for acute and 148 of 167 studies for nonacute clinical indication. Twenty-five false-negative diagnoses paneled in three groups were made by all readers together. Readers misread four of 19 studies with acute and 21 of 148 studies with nonacute clinical indication. Four of 21 misread studies with nonacute indications harbored unexpected findings needing management. Axial T2 screening can detect pediatric brain abnormalities with high sensitivity and specificity and can possibly replace CT as screening tool if the reading physician is aware of possible limitations/pitfalls. The level of experience influences sensitivity and specificity. Adding diffusion-weighted imaging and susceptibility-weighted imaging to a 3-dimensional T2-weighted sequence would most likely further increase sensitivity and specificity. Copyright © 2015 by the American Society of Neuroimaging.

  10. Double versus single reading of mammograms in a breast cancer screening programme: a cost-consequence analysis.

    PubMed

    Posso, Margarita C; Puig, Teresa; Quintana, Ma Jesus; Solà-Roca, Judit; Bonfill, Xavier

    2016-09-01

    To assess the costs and health-related outcomes of double versus single reading of digital mammograms in a breast cancer screening programme. Based on data from 57,157 digital screening mammograms from women aged 50-69 years, we compared costs, false-positive results, positive predictive value and cancer detection rate using four reading strategies: double reading with and without consensus and arbitration, and single reading with first reader only and second reader only. Four highly trained radiologists read the mammograms. Double reading with consensus and arbitration was 15 % (Euro 334,341) more expensive than single reading with first reader only. False-positive results were more frequent at double reading with consensus and arbitration than at single reading with first reader only (4.5 % and 4.2 %, respectively; p < 0.001). The positive predictive value (9.3 % and 9.1 %; p = 0.812) and cancer detection rate were similar for both reading strategies (4.6 and 4.2 per 1000 screens; p = 0.283). Our results suggest that changing to single reading of mammograms could produce savings in breast cancer screening. Single reading could reduce the frequency of false-positive results without changing the cancer detection rate. These results are not conclusive and cannot be generalized to other contexts with less trained radiologists. • Double reading of digital mammograms is more expensive than single reading. • Compared to single reading, double reading yields a higher proportion of false-positive results. • The cancer detection rate was similar for double and single readings. • Single reading may be a cost-effective strategy in breast cancer screening programmes.

  11. Custodial Management in the Information Age.

    ERIC Educational Resources Information Center

    Harris, Jim, Sr.

    1999-01-01

    Explains how computerizing the custodial department can be achieved through bar coding, hand-held readers, and the appropriate software packages. Software programs that aid cleaning management, track assets, and manage stock are discussed. (GR)

  12. TOPEX Software Document Series. Volume 5; Rev. 1; TOPEX GDR Processing

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey; Lockwood, Dennis; Hancock, David W., III

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Geophysical Data Record (GDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  13. Electrophoretic display technologies for e-book readers: system integration aspects

    NASA Astrophysics Data System (ADS)

    Gentric, Philippe

    2011-03-01

    Emerging screen technologies, such as Electrophoretic Displays (EPD) used in E-book Readers, are changing product power requirements due to their advantageous properties such as bi-stability (effective "zero power" static display) and reflective mode of operation (no backlight). We will first review the emerging screen technologies under the angle of system and IC design impact. We will explain power management consequences for IC design, with a focus on Application Engine SOCs for the wireless/portable markets.

  14. Web usability evaluation with screen reader users: implementation of the partial concurrent thinking aloud technique.

    PubMed

    Federici, Stefano; Stefano, Federici; Borsci, Simone; Stamerra, Gianluca

    2010-08-01

    A verbal protocol technique, adopted for a web usability evaluation, requires that the users are able to perform a double task: surfing and talking. Nevertheless, when blind users surf by using a screen reader and talk about the way they interact with the computer, the evaluation is influenced by a structural interference: users are forced to think aloud and listen to the screen reader at the same time. The aim of this study is to build up a verbal protocol technique for samples of visual impaired users in order to overcome the limits of concurrent and retrospective protocols. The technique we improved, called partial concurrent thinking aloud (PCTA), integrates a modified set of concurrent verbalization and retrospective analysis. One group of 6 blind users and another group of 6 sighted users evaluated the usability of a website using PCTA. By estimating the number of necessary users by the means of an asymptotic test, it was found out that the two groups had an equivalent ability of identifying usability problems, both over 80%. The result suggests that PCTA, while respecting the properties of classic verbal protocols, also allows to overcome the structural interference and the limits of concurrent and retrospective protocols when used with screen reader users. In this way, PCTA reduces the efficiency difference of usability evaluation between blind and sighted users.

  15. Can a limited double reading/second opinion of initially recalled breast ultrasound screening examinations improve radiologists' performances?

    NASA Astrophysics Data System (ADS)

    Gur, David; Harnist, Kimberly; Gizienski, Terri-Ann; Zuley, Margarita; Hakim, Christiane; Lu, Amy; Sumkin, Jules; Abrams, Gordon; Ganott, Marie A.; Kelly, Amy E.; Tyma, Cathy S.; Chang, Thomas; BÓ§hm-Vélez, Marcella; Sobolewski, Robin

    2018-03-01

    Interpretations of breast ultrasound screening examinations result in high recall rates and large inter-radiologist variability, frequently leading to "conservative" recommendations. Double reading of all breast ultrasound screening examinations is cost prohibitive, but double reading of only "initially recalled" cases may prove efficacious. We assessed changes in recommendations, if any, by providing a consensus second opinion in a limited subset of examinations initially recommended for recall. We performed a retrospective reader study with 197 ultrasound examinations (97 not recalled and 100 recalled clinically). First, we generated a consensus "second opinion" consisting of the majority vote of three independent readings of each case by experienced ultrasound interpreters. During the reader study that followed, if the reader recommended a "recall" and the "consensus second opinion" did not, a message to that effect was displayed and the reader was asked to re-review the exam and re-assess if, knowing the second opinion, a re-rating of the case was warranted. We compared performance levels pre- and post- the second opinion. The second opinion resulted in "no recall" recommendations of 141 cases in the entire set, including four cancer cases missed by all three readers. On average, radiologists received "warning" messages in 30 cases (range 15-50), or in 15% of cases. Rating changes (downgrades to no recall) occurred in 36 of these cases. These changes resulted in a possible recall rate reduction of 28% in prompted cases or 14% overall recall reduction, while increasing the false negative rate by only one case missed by 2 readers ( 1%).

  16. Double Reading in Breast Cancer Screening: Cohort Evaluation in the CO-OPS Trial.

    PubMed

    Taylor-Phillips, Sian; Jenkinson, David; Stinton, Chris; Wallis, Matthew G; Dunn, Janet; Clarke, Aileen

    2018-04-10

    Purpose To investigate the effect of double readings by a second radiologist on recall rates, cancer detection, and characteristics of cancers detected in the National Health Service Breast Screening Program in England. Materials and Methods In this retrospective analysis, 805 206 women were evaluated through screening and diagnostic test results by extracting 1 year of routine data from 33 English breast screening centers. Centers used double reading of digital mammograms, with arbitration if there were discrepant interpretations. Information on reader decisions, with results of follow-up tests, were used to explore the effect of the second reader. The statistical tests used were the test for equality of proportions, the χ 2 test for independence, and the t test. Results The first reader recalled 4.76% of women (38 295 of 805 206 women; 95% confidence interval [CI]: 4.71%, 4.80%). Two readers recalled 6.19% of women in total (49 857 of 805 206 women; 95% CI: 6.14%, 6.24%), but arbitration of discordant readings reduced the recall rate to 4.08% (32 863 of 805 206 women; 95% CI: 4.04%, 4.12%; P < .001). A total of 7055 cancers were detected, of which 627 (8.89%; 95% CI: 8.22%, 9.55%; P < .001) were detected by the second reader only. These additional cancers were more likely to be ductal carcinoma in situ (30.5% [183 of 600] vs 22.0% [1344 of 6114]; P < .001), and additional invasive cancers were smaller (mean size, 14.2 vs 16.7 mm; P < .001), had fewer involved nodes, and were likely to be lower grade. Conclusion Double reading with arbitration reduces recall and increases cancer detection compared with single reading. Cancers detected only by the second reader were smaller, of lower grade, and had less nodal involvement. © RSNA, 2018.

  17. Spatial Identification of Passive Radio Frequency Identification Tags Using Software Defined Radios

    DTIC Science & Technology

    2012-03-01

    75 3.4 Experiment Configurations . . . . . . . . . . . . . . . . . . . . 77 4.1 Simulation Enviromental Elements . . . . . . . . . . . . . . . . 79...tabletop zReader 20cm Tag vertical offset from reader z 10 cm 3dB angle of sensor antenna theat3db 0.698 radians Table 4.1: Simulation Enviromental

  18. Technology Tips: A Potpourri.

    ERIC Educational Resources Information Center

    Cuoco, Albert A.; And Others, Eds.

    1994-01-01

    Contains tips from readers about using technology in the classroom, including notebook computers, classroom sets of calculators, geometry software, LOGO software, publisher discounts, curriculum materials in CD-ROM, and volunteer help in computers and computer networking for schools. (MKR)

  19. Supporting Struggling Readers in Secondary School Science Classes

    ERIC Educational Resources Information Center

    Roberts, Kelly D.; Takahashi, Kiriko; Park, Hye-Jin; Stodden, Robert A.

    2012-01-01

    Many secondary school students struggle to read complex expository text such as science textbooks. This article provides step-by-step guidance on how to foster expository reading for struggling readers in secondary school science classes. Two strategies are introduced: Text-to-Speech (TTS) Software as a reading compensatory strategy and the…

  20. WFF TOPEX Software Documentation Altimeter Instrument File (AIF) Processing, October 1998. Volume 3

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey; Lockwood, Dennis

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  1. Computational assessment of mammography accreditation phantom images and correlation with human observer analysis

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Lau, Kristen C.; Schiabel, Homero; Maidment, D. A.

    2015-03-01

    Routine performance of basic test procedures and dose measurements are essential for assuring high quality of mammograms. International guidelines recommend that breast care providers ascertain that mammography systems produce a constant high quality image, using as low a radiation dose as is reasonably achievable. The main purpose of this research is to develop a framework to monitor radiation dose and image quality in a mixed breast screening and diagnostic imaging environment using an automated tracking system. This study presents a module of this framework, consisting of a computerized system to measure the image quality of the American College of Radiology mammography accreditation phantom. The methods developed combine correlation approaches, matched filters, and data mining techniques. These methods have been used to analyze radiological images of the accreditation phantom. The classification of structures of interest is based upon reports produced by four trained readers. As previously reported, human observers demonstrate great variation in their analysis due to the subjectivity of human visual inspection. The software tool was trained with three sets of 60 phantom images in order to generate decision trees using the software WEKA (Waikato Environment for Knowledge Analysis). When tested with 240 images during the classification step, the tool correctly classified 88%, 99%, and 98%, of fibers, speck groups and masses, respectively. The variation between the computer classification and human reading was comparable to the variation between human readers. This computerized system not only automates the quality control procedure in mammography, but also decreases the subjectivity in the expert evaluation of the phantom images.

  2. TOPEX SDR Processing, October 1998. Volume 4

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey E.; Lockwood, Dennis W.

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  3. Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

    PubMed

    Enomoto, Yukiko; Yamauchi, Keita; Asano, Takahiko; Otani, Katharina; Iwama, Toru

    2018-01-01

    Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p < 0.001). Additional clinical findings were seen on CBCT images of 70.4% of patients after MAR correction. Conclusion MAR software improved image quality of CBCT images degraded by metal artifacts.

  4. Protocols and programs for high-throughput growth and aging phenotyping in yeast.

    PubMed

    Jung, Paul P; Christian, Nils; Kay, Daniel P; Skupin, Alexander; Linster, Carole L

    2015-01-01

    In microorganisms, and more particularly in yeasts, a standard phenotyping approach consists in the analysis of fitness by growth rate determination in different conditions. One growth assay that combines high throughput with high resolution involves the generation of growth curves from 96-well plate microcultivations in thermostated and shaking plate readers. To push the throughput of this method to the next level, we have adapted it in this study to the use of 384-well plates. The values of the extracted growth parameters (lag time, doubling time and yield of biomass) correlated well between experiments carried out in 384-well plates as compared to 96-well plates or batch cultures, validating the higher-throughput approach for phenotypic screens. The method is not restricted to the use of the budding yeast Saccharomyces cerevisiae, as shown by consistent results for other species selected from the Hemiascomycete class. Furthermore, we used the 384-well plate microcultivations to develop and validate a higher-throughput assay for yeast Chronological Life Span (CLS), a parameter that is still commonly determined by a cumbersome method based on counting "Colony Forming Units". To accelerate analysis of the large datasets generated by the described growth and aging assays, we developed the freely available software tools GATHODE and CATHODE. These tools allow for semi-automatic determination of growth parameters and CLS behavior from typical plate reader output files. The described protocols and programs will increase the time- and cost-efficiency of a number of yeast-based systems genetics experiments as well as various types of screens.

  5. Changing behavior and accuracy with time on task in mammography screening

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, Sian; Jenkinson, David; Stinton, Chris; Wallis, Matthew G.; Clarke, Aileen

    2017-03-01

    Background: The vigilance decrement and prevalence effect both describe changes to speed and accuracy with time on task. Whilst there is much laboratory based research on these effects, little is known about whether they occur in real world mammography practice. Methods: The Changing Case Order to Optimise Patterns of Performance in Screening (CO-OPS) trial randomised 37,724 batches containing 1.2 million women attending breast screening to intervention or control (222,208 from the Midlands of England). In the control arm the batch was examined in the same order by both readers, in the intervention arm it was examined in a different order by both readers. Time taken, recall decision by both readers, and cancers detected were recorded for each case, and used to examine patterns of performance with time on task. Results: 49,575 women were recalled and 10,484 had cancer detected. Median time taken to examine each case was 35 seconds (out of cases where time taken was 10 minutes or less). The intervention did not affect overall cancer detection rates or recall rates. A more detailed analysis of the Midlands data indicates cancer detection rate did not change when reading up to 60 cases in a batch, but recall rate reduced. Time taken per case reduced with time on task, from a median 41 seconds when examining the second case in the batch to 28.5 seconds examining the 60th case. Conclusion: Reader behavior and performance systematically changes with time on task in breast screening.

  6. Designing the user interface: strategies for effective human-computer interaction

    NASA Astrophysics Data System (ADS)

    Shneiderman, B.

    1998-03-01

    In revising this popular book, Ben Shneiderman again provides a complete, current and authoritative introduction to user-interface design. The user interface is the part of every computer system that determines how people control and operate that system. When the interface is well designed, it is comprehensible, predictable, and controllable; users feel competent, satisfied, and responsible for their actions. Shneiderman discusses the principles and practices needed to design such effective interaction. Based on 20 years experience, Shneiderman offers readers practical techniques and guidelines for interface design. He also takes great care to discuss underlying issues and to support conclusions with empirical results. Interface designers, software engineers, and product managers will all find this book an invaluable resource for creating systems that facilitate rapid learning and performance, yield low error rates, and generate high user satisfaction. Coverage includes the human factors of interactive software (with a new discussion of diverse user communities), tested methods to develop and assess interfaces, interaction styles such as direct manipulation for graphical user interfaces, and design considerations such as effective messages, consistent screen design, and appropriate color.

  7. Breast screening: the use of consensus opinion for all recalls.

    PubMed

    Matcham, N J; Ridley, N T F; Taylor, S J; Cook, J-L; Scolding, J

    2004-06-01

    The quality of a breast-screening programme is measured not only by it's cancer detection rates (sensitivity), but also by it's recall rates and positive predictive values (specificity). False positive screens, which lead to assessments with benign outcomes, can cause psychological and physical morbidity in previously well women. In 1999 the Wiltshire breast-screening programme adopted a novel recall strategy whereby all films marked for recall are subject to consensus opinion--even women "recalled" by both original readers may be returned to routine screening. Since 1999 our recall rates have fallen from above to below the national averages (prevalent 7.2% and incident 3.0% in 2001/02). Specificity has increased over the same period such that approximately one in seven women assessed will be diagnosed with cancer. The consensus meetings provide a forum for teaching and are very popular with our film readers, who all report reduced levels of stress. Copyright 2003 Elsevier Ltd.

  8. Analytical Design of Evolvable Software for High-Assurance Computing

    DTIC Science & Technology

    2001-02-14

    Mathematical expression for the Total Sum of Squares which measures the variability that results when all values are treated as a combined sample coming from...primarily interested in background on software design and high-assurance computing, research in software architecture generation or evaluation...respectively. Those readers solely interested in the validation of a software design approach should at the minimum read Chapter 6 followed by Chapter

  9. [Establishment of an in vitro screening model for steroid 5 alpha-reductase inhibitors with the microplate reader].

    PubMed

    Wu, Jian-Hui; Sun, Zu-Yue

    2013-06-01

    To establish an in vitro screening model for steroid 5 alpha-reductase inhibitors using the microplate reader. Steroid 5 alpha-reductase was obtained from the liver of female rats, an in vitro screening model for steroid 5 alpha-reductase inhibitors established using the 96-well plate and microplate reader after determination of the enzymatic activity, and the reliability of the model verified with the known 5 alpha-reductase inhibitors epristeride and finasteride. Added to the 96-well plate were the final concentrations of testosterone (0-40 micromol/L), NADPH (22 micromol/L), epristeride (0-60 nmol/L) or finasteride (0-60 nmol/ L) and steroid 5 alpha-reductase (20 microl), the total volume of each well adjusted to 200 microl with Tris-Hcl buffer. The 96-well plate was placed in the microplate reader, mixed and incubated at 37 degrees C, followed by detection of the A340nm value at 0 and 10 min and analysis of the data. The Km value of steroid 5 alpha-reductase was 3.794 micromol/L, with a Vmax of 0.271 micromol/(L. min). The Ki of epristeride was 148.2 nmol/L, with an IC50 of 31.5 nmol/L, and the enzymatic reaction kinetic curve suggested that epristeride was an uncompetitive enzyme inhibitor. The Ki of finasteride was 158. 8 nmol/L, with an IC50 of 13.6 nmol/L. The enzymatic reaction kinetic curve showed that both epristeride and finasteride were competitive enzyme inhibitors, similar to those reported in the published literature. A screening model was successfully established, which could rapidly and effectively screen steroid 5 alpha-reductase inhibitors in vitro.

  10. Example Elaboration as a Neglected Instructional Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Girill, T R

    Over the last decade an unfolding cognitive-psychology research program on how learners use examples to develop effective problem solving expertise has yielded well-established empirical findings. Chi et al., Renkl, Reimann, and Neubert (in various papers) have confirmed statistically significant differences in how good and poor learners inferentially elaborate (self explain) example steps as they study. Such example elaboration is highly relevant to software documentation and training, yet largely neglected in the current literature. This paper summarizes the neglected research on example use and puts its neglect in a disciplinary perspective. The author then shows that differences in support for examplemore » elaboration in commercial software documentation reveal previously over looked usability issues. These issues involve example summaries, using goals and goal structures to reinforce example elaborations, and prompting readers to recognize the role of example parts. Secondly, I show how these same example elaboration techniques can build cognitive maturity among underperforming high school students who study technical writing. Principle based elaborations, condition elaborations, and role recognition of example steps all have their place in innovative, high school level, technical writing exercises, and all promote far transfer problem solving. Finally, I use these studies to clarify the constructivist debate over what writers and readers contribute to text meaning. I argue that writers can influence how readers elaborate on examples, and that because of the great empirical differences in example study effectiveness (and reader choices) writers should do what they can (through within text design features) to encourage readers to elaborate examples in the most successful ways. Example elaboration is a uniquely effective way to learn from worked technical examples. This paper summarizes years of research that clarifies example elaboration. I then show how example elaboration can make complex software documentation more useful, improve the benefits of technical writing exercises for underperforming students, and enlighten the general discussion of how writers can and should help their readers.« less

  11. Automated chest-radiography as a triage for Xpert testing in resource-constrained settings: a prospective study of diagnostic accuracy and costs

    NASA Astrophysics Data System (ADS)

    Philipsen, R. H. H. M.; Sánchez, C. I.; Maduskar, P.; Melendez, J.; Peters-Bax, L.; Peter, J. G.; Dawson, R.; Theron, G.; Dheda, K.; van Ginneken, B.

    2015-07-01

    Molecular tests hold great potential for tuberculosis (TB) diagnosis, but are costly, time consuming, and HIV-infected patients are often sputum scarce. Therefore, alternative approaches are needed. We evaluated automated digital chest radiography (ACR) as a rapid and cheap pre-screen test prior to Xpert MTB/RIF (Xpert). 388 suspected TB subjects underwent chest radiography, Xpert and sputum culture testing. Radiographs were analysed by computer software (CAD4TB) and specialist readers, and abnormality scores were allocated. A triage algorithm was simulated in which subjects with a score above a threshold underwent Xpert. We computed sensitivity, specificity, cost per screened subject (CSS), cost per notified TB case (CNTBC) and throughput for different diagnostic thresholds. 18.3% of subjects had culture positive TB. For Xpert alone, sensitivity was 78.9%, specificity 98.1%, CSS $13.09 and CNTBC $90.70. In a pre-screening setting where 40% of subjects would undergo Xpert, CSS decreased to $6.72 and CNTBC to $54.34, with eight TB cases missed and throughput increased from 45 to 113 patients/day. Specialists, on average, read 57% of radiographs as abnormal, reducing CSS ($8.95) and CNTBC ($64.84). ACR pre-screening could substantially reduce costs, and increase daily throughput with few TB cases missed. These data inform public health policy in resource-constrained settings.

  12. The Potential Role of Grid-Like Software in Bedside Chest Radiography in Improving Image Quality and Dose Reduction: An Observer Preference Study.

    PubMed

    Ahn, Su Yeon; Chae, Kum Ju; Goo, Jin Mo

    2018-01-01

    To compare the observer preference of image quality and radiation dose between non-grid, grid-like, and grid images. Each of the 38 patients underwent bedside chest radiography with and without a grid. A grid-like image was generated from a non-grid image using SimGrid software (Samsung Electronics Co. Ltd.) employing deep-learning-based scatter correction technology. Two readers recorded the preference for 10 anatomic landmarks and the overall appearance on a five-point scale for a pair of non-grid and grid-like images, and a pair of grid-like and grid images, respectively, which were randomly presented. The dose area product (DAP) was also recorded. Wilcoxon's rank sum test was used to assess the significance of preference. Both readers preferred grid-like images to non-grid images significantly ( p < 0.001); with a significant difference in terms of the preference for grid images to grid-like images ( p = 0.317, 0.034, respectively). In terms of anatomic landmarks, both readers preferred grid-like images to non-grid images ( p < 0.05). No significant differences existed between grid-like and grid images except for the preference for grid images in proximal airways by two readers, and in retrocardiac lung and thoracic spine by one reader. The median DAP were 1.48 (range, 1.37-2.17) dGy * cm 2 in grid images and 1.22 (range, 1.11-1.78) dGy * cm 2 in grid-like images with a significant difference ( p < 0.001). The SimGrid software significantly improved the image quality of non-grid images to a level comparable to that of grid images with a relatively lower level of radiation exposure.

  13. Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements.

    PubMed

    McCloskey, Kate; Ponsonby, Anne-Louise; Carlin, John B; Jachno, Kim; Cheung, Michael; Skilton, Michael R; Koleff, Jane; Vuillermin, Peter; Burgner, David

    2014-06-03

    Aortic intima-media thickness measured by transabdominal ultrasound (aIMT) is an intermediate phenotype of cardiovascular risk. We aimed to (1) investigate the reproducibility of aIMT in a population-derived cohort of infants; (2) establish the distribution of aIMT in early infancy; (3) compare measurement by edge-detection software to that by manual sonographic calipers; and (4) assess the effect of individual and environmental variables on image quality. Participants were term infants recruited to a population-derived birth cohort study. Transabdominal ultrasound was performed at six weeks of age by one of two trained operators. Thirty participants had ultrasounds performed by both operators on the same day. Data were collected on environmental (infant sleeping, presence of a sibling, use of sucrose, timing during study visit) and individual (post-conception age, weight, gender) variables. Two readers assessed image quality and measured aIMT by edge-detection software and a subset by manual sonographic calipers. Measurements were repeated by the same reader and between readers to obtain intra-observer and inter-observer reliability. Aortic IMT was measured successfully using edge-detection in 814 infants, and 290 of these infants also had aIMT measured using manual sonographic calipers. The intra-reader intra-class correlation (ICC) (n = 20) was 0.90 (95% CI 0.76, 0.96), mean difference 1.5 μm (95% LOA -39, 59). The between reader ICC using edge-detection (n = 20) was 0.92 (95% CI 0.82, 0.97) mean difference 2 μm (95% LOA -45.0, 49.0) and with manual caliper measurement (n = 290) the ICC was 0.84 (95% CI 0.80, 0.87) mean difference 5 μm (95% LOA -51.8, 61.8). Edge-detection measurements were greater than those from manual sonographic calipers (mean aIMT 618 μm (50) versus mean aIMT 563 μm (49) respectively; p < 0.001, mean difference 44 μm, 95% LOA -54, 142). With the exception of infant crying (p = 0.001), no associations were observed between individual and environmental variables and image quality. In a population-derived cohort of term infants, aIMT measurement has a high level of intra and inter-reader reproducibility. Measurement of aIMT using edge-detection software gives higher inter-reader ICC than manual sonographic calipers. Image quality is not substantially affected by individual and environmental factors.

  14. Advanced Chemistry Collection, 2nd Edition

    NASA Astrophysics Data System (ADS)

    2001-11-01

    Software requirements are given in Table 3. Some programs have additional special requirements. Please see the individual program abstracts at JCE Online or the documentation included on the CD-ROM for more specific information. Table 3. General software requirements for the Advanced Chemistry Collection.

    ComputerSystemOther Software(Required by one or more programs)
    Mac OS compatibleSystem 7.6.1 or higherAcrobat Reader (included)Mathcad; Mathematica;MacMolecule2; QuickTime 4; HyperCard Player
    Windows CompatibleWindows 2000, 98, 95, NT 4Acrobat Reader (included)Mathcad; Mathematica;PCMolecule2; QuickTime 4;HyperChem; Excel

    Literature Cited

    1. General Chemistry Collection, 5th ed.; J. Chem. Educ. Software, 2001, SP16.
    2. Advanced Chemistry Collection; J. Chem. Educ. Software, 2001, SP28.

  15. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    PubMed Central

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473

  16. A comparative analysis of standard microtiter plate reading versus imaging in cellular assays.

    PubMed

    Bushway, Paul J; Mercola, Mark; Price, Jeffrey H

    2008-08-01

    We evaluated the performance of two plate readers (the Beckman Coulter [Fullerton, CA] DTX and the PerkinElmer [Wellesley, MA] EnVision) and a plate imager (the General Electric [Fairfield, CT] IN Cell 1000 Analyzer) in a primary fluorescent cellular screen of 10,000 Molecular Libraries Screening Center Network library compounds for up- and down-regulation of vascular cell adhesion molecule (VCAM)-1, which has been shown to be up-regulated in atherothrombotic vascular disease and is a general indicator of chronic inflammatory disease. Prior to screening, imaging of a twofold, six-step titration of fluorescent cells in a 384-well test plate showed greater consistency, sensitivity, and dynamic range of signal detection curves throughout the detection range, as compared to the plate readers. With the same 384-well test plate, the detection limits for fluorescent protein-labeled cells on the DTX and EnVision instruments were 2,250 and 560 fluorescent cells per well, respectively, as compared to 280 on the IN Cell 1000. During VCAM screening, sensitivity was critical for detection of antagonists, which reduced brightness of the primary immunofluorescence readout; inhibitor controls yielded Z' values of 0.41 and 0.16 for the IN Cell 1000 and EnVision instruments, respectively. The best 1% of small molecule inhibitors from all platforms were visually confirmed using images from the IN Cell 1000. The EnVision and DTX plate readers mutually identified approximately 57% and 21%, respectively, of the VCAM-1 inhibitors visually confirmed in the IN Cell best 1% of inhibitors. Furthermore, the plate reader hits were largely exclusive, with only 6% agreement across all platforms (three hits out of 47). Taken together, the imager outperformed the plate readers at hit detection in this bimodal assay because of superior sensitivity and had the advantage of speeding hit confirmation during post-acquisition analysis.

  17. Real-time inference of word relevance from electroencephalogram and eye gaze

    NASA Astrophysics Data System (ADS)

    Wenzel, M. A.; Bogojeski, M.; Blankertz, B.

    2017-10-01

    Objective. Brain-computer interfaces can potentially map the subjective relevance of the visual surroundings, based on neural activity and eye movements, in order to infer the interest of a person in real-time. Approach. Readers looked for words belonging to one out of five semantic categories, while a stream of words passed at different locations on the screen. It was estimated in real-time which words and thus which semantic category interested each reader based on the electroencephalogram (EEG) and the eye gaze. Main results. Words that were subjectively relevant could be decoded online from the signals. The estimation resulted in an average rank of 1.62 for the category of interest among the five categories after a hundred words had been read. Significance. It was demonstrated that the interest of a reader can be inferred online from EEG and eye tracking signals, which can potentially be used in novel types of adaptive software, which enrich the interaction by adding implicit information about the interest of the user to the explicit interaction. The study is characterised by the following novelties. Interpretation with respect to the word meaning was necessary in contrast to the usual practice in brain-computer interfacing where stimulus recognition is sufficient. The typical counting task was avoided because it would not be sensible for implicit relevance detection. Several words were displayed at the same time, in contrast to the typical sequences of single stimuli. Neural activity was related with eye tracking to the words, which were scanned without restrictions on the eye movements.

  18. New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment.

    PubMed

    Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David

    2017-03-01

    The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.

  19. CT colonography: automated measurement of colonic polyps compared with manual techniques--human in vitro study.

    PubMed

    Taylor, Stuart A; Slater, Andrew; Halligan, Steve; Honeyfield, Lesley; Roddie, Mary E; Demeshski, Jamshid; Amin, Hamdam; Burling, David

    2007-01-01

    To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. Institutional review board approval was obtained for the study; written consent for use of the surgical specimen was obtained. A colectomy specimen containing 27 polyps from a 16-year-old male patient with familial adenomatous polyposis was insufflated, submerged in a container with solution, and scanned at four-section multi-detector row computed tomography (CT). A histopathologist measured the maximum dimension of all polyps in the opened specimen. Digital photographs and line drawings were produced to aid CT-histologic measurement correlation. A novice (radiographic technician) and an experienced (radiologist) observer independently estimated polyp diameter with three methods: manual two-dimensional (2D) and manual three-dimensional (3D) measurement with software calipers and automated measurement with software (automatic). Data were analyzed with paired t tests and Bland-Altman limits of agreement. Seven polyps (

  20. "Do I Have to Leave?" Beyond Linear Text: Struggling Readers' Motivation with an Innovative Musical Program

    ERIC Educational Resources Information Center

    Bennett, Susan V.; Calderone, Cynthia; Dedrick, Robert F.; Gunn, AnnMarie Alberton

    2015-01-01

    In this mixed method research, we examined the effects of reading and singing software program (RSSP) as a reading intervention on struggling readers' reading achievement as measured by the Florida Comprehensive Assessment Test, the high stakes state test administered in the state of Florida, at one elementary school. Our team defined struggling…

  1. Promoting Reading: Using eBooks with Gifted and Advanced Readers

    ERIC Educational Resources Information Center

    Weber, Christine L.; Cavanaugh, Terence W.

    2006-01-01

    eBooks are textual documents that have been converted and "published" in an electronic format and are displayed on eBook readers, devices, or computers using eBook software programs. This new form of book is a relatively recent addition to book styles and offers students, teachers, and schools an additional tool for the teaching of reading and the…

  2. Using Computer Technology To Aid the Disabled Reader.

    ERIC Educational Resources Information Center

    Balajthy, Ernest

    When matched for achievement level and educational objectives, computer technology can be particularly effective with at-risk students. Computer-assisted instructional software is the most widely available type of software. An exciting development pertinent to literacy education is the development of the "electronic book" (also called…

  3. Basic Internet Software Toolkit.

    ERIC Educational Resources Information Center

    Buchanan, Larry

    1998-01-01

    Once schools are connected to the Internet, the next step is getting network workstations configured for Internet access. This article describes a basic toolkit comprising software currently available on the Internet for free or modest cost. Lists URLs for Web browser, Telnet, FTP, file decompression, portable document format (PDF) reader,…

  4. The Relationship between Good Readers' Attention, Reading Fluency and Reading Comprehension

    ERIC Educational Resources Information Center

    Yildiz, Mustafa; Çetinkaya, Ezgi

    2017-01-01

    This study aimed to examine the relationship between fourth-graders' reading fluency, reading comprehension and attention. It was conducted using the relational screening model and included 132 fourth-graders with grade level adequate reading skills. The study results showed that good readers' attention had significant effects on reading speed,…

  5. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other.

    PubMed

    Kok, P; Pitman, A G; Cawson, J N; Gledhill, S; Kremer, S; Lawson, J; Mehta, K; Mercuri, V; Shnier, D; Taft, R; Zentner, L

    2010-08-01

    The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from <1 year to >20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i.e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.50-0.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and any of the diagnostic accuracy measures in our group of readers. In particular, there was no correlation between diagnostic accuracy and memory performance. There was no association between visual memory performance and diagnostic accuracy as a screening mammographer in our group of eight representative readers. Whether a radiologist has a good or a bad visual memory for cases, and in particular mammograms, should not impact on his or her performance as a radiologist and mammogram reader.

  6. Can ultrasound be used as the primary imaging in children with suspected Crohn disease?

    PubMed

    Tsai, Timothy L; Marine, Megan B; Wanner, Matthew R; Cooper, Matthew L; Steiner, Steven J; Ouyang, Fangqian; Gregory Jennings, S; Karmazyn, Boaz

    2017-07-01

    There is growing literature on the use of ultrasound (US) for evaluation of Crohn disease in adults, but few studies have been conducted on children. Several studies demonstrated high accuracy of US in the diagnosis of Crohn disease. Using US as the primary screening imaging modality for Crohn disease can reduce health care costs, the need for sedation and ionizing radiation exposure. The aim of our study is to determine if US can be used for screening evaluation of pediatric Crohn disease. A prospective cohort study of pediatric patients undergoing MR enterography (MRE) for suspected or known history of Crohn disease was performed, with gray-scale and Doppler US of the terminal ileum done immediately before or after MRE. US images were interpreted by two radiologists (Reader 1 and Reader 2) not involved in image acquisition, in blinded and randomized fashion. US findings of Crohn disease including bowel wall thickening, wall stratification, increased vascularity on Doppler, lymphadenopathy, fat infiltration and extraintestinal complications were evaluated. MRE findings of terminal ileitis were considered the reference standard. Demographic data, body mass index (BMI), symptoms, and laboratory, endoscopic and histopathological data were obtained from electronic medical records. Forty-one patients (mean age: 13.7 years: 4.6-18.9 years) were evaluated. Mean BMI was 21.2 (range: 13-40.2); 10 patients (24.3%) were either overweight or obese. Final diagnoses were Crohn disease (n=24), ulcerative colitis (n=4) and normal/non-inflammatory bowel disease-related diagnoses (n=13). US demonstrated sensitivity of 67% and 78% and specificity of 78% and 83%, by Reader 1 and Reader 2, respectively. MRE sensitivity and specificity were 75% and 100%, respectively, compared to final clinicopathological diagnosis. Interobserver agreement between Reader 1 and Reader 2 was good (0.6< kappa <0.8). In screening for Crohn disease in children, US has limited sensitivity for detecting terminal ileitis.

  7. Classification of breast cancer in ultrasound imaging using a generic deep learning analysis software: a pilot study.

    PubMed

    Becker, Anton S; Mueller, Michael; Stoffel, Elina; Marcon, Magda; Ghafoor, Soleen; Boss, Andreas

    2018-02-01

    To train a generic deep learning software (DLS) to classify breast cancer on ultrasound images and to compare its performance to human readers with variable breast imaging experience. In this retrospective study, all breast ultrasound examinations from January 1, 2014 to December 31, 2014 at our institution were reviewed. Patients with post-surgical scars, initially indeterminate, or malignant lesions with histological diagnoses or 2-year follow-up were included. The DLS was trained with 70% of the images, and the remaining 30% were used to validate the performance. Three readers with variable expertise also evaluated the validation set (radiologist, resident, medical student). Diagnostic accuracy was assessed with a receiver operating characteristic analysis. 82 patients with malignant and 550 with benign lesions were included. Time needed for training was 7 min (DLS). Evaluation time for the test data set were 3.7 s (DLS) and 28, 22 and 25 min for human readers (decreasing experience). Receiver operating characteristic analysis revealed non-significant differences (p-values 0.45-0.47) in the area under the curve of 0.84 (DLS), 0.88 (experienced and intermediate readers) and 0.79 (inexperienced reader). DLS may aid diagnosing cancer on breast ultrasound images with an accuracy comparable to radiologists, and learns better and faster than a human reader with no prior experience. Further clinical trials with dedicated algorithms are warranted. Advances in knowledge: DLS can be trained classify cancer on breast ultrasound images high accuracy even with comparably few training cases. The fast evaluation speed makes real-time image analysis feasible.

  8. Quality Improvement With Discrete Event Simulation: A Primer for Radiologists.

    PubMed

    Booker, Michael T; O'Connell, Ryan J; Desai, Bhushan; Duddalwar, Vinay A

    2016-04-01

    The application of simulation software in health care has transformed quality and process improvement. Specifically, software based on discrete-event simulation (DES) has shown the ability to improve radiology workflows and systems. Nevertheless, despite the successful application of DES in the medical literature, the power and value of simulation remains underutilized. For this reason, the basics of DES modeling are introduced, with specific attention to medical imaging. In an effort to provide readers with the tools necessary to begin their own DES analyses, the practical steps of choosing a software package and building a basic radiology model are discussed. In addition, three radiology system examples are presented, with accompanying DES models that assist in analysis and decision making. Through these simulations, we provide readers with an understanding of the theory, requirements, and benefits of implementing DES in their own radiology practices. Copyright © 2016 American College of Radiology. All rights reserved.

  9. ADAM -- Unix Version

    NASA Astrophysics Data System (ADS)

    Chipperfield, A. J.

    This document describes the use of the Starlink Software Environment, ADAM, on Unix. It is primarily of use to programmers but the early sections contain information useful to any user. It is assumed that the reader is familiar with the concepts of ADAM programming and that the Starlink software is installed in the standard way.

  10. COMPILATION OF SATURATED AND UNSATURATED ZONE MODELING SOFTWARE

    EPA Science Inventory

    The full report provides readers an overview of available ground-water modeling programs and related software. It is an update of EPA/600/R-93/118 and EPA/600/R-94/028, two previous reports from the same program at the International Ground Water Modeling Center (IGWMC) in Colora...

  11. The Educational Software/Website Effectiveness Survey

    ERIC Educational Resources Information Center

    Furner, Joseph M.; Daigle, Debra

    2004-01-01

    In today's growing technological age of educational software and interactive Internet teaching/learning websites, it is important to note that educators must take the time to see that the interactive electronic experiences their students are involved meet the appropriate standards, hence been evaluated. This article provides the readers with an…

  12. A microplate reader-based method to quantify NADH-cytochrome b5 reductase activity for diagnosis of recessive congenital methaemoglobinemia.

    PubMed

    Kedar, Prabhakar; Desai, Anand; Warang, Prashant; Colah, Roshan

    2017-05-01

    Congenital methemoglobinemia due to NADH-cytochrome b5 reductase 3 (CYB5R3) deficiencies is an autosomal recessive disorder that occurs sporadically worldwide, A sensitive, accurate, and rapid analysis of NADH-CYB5R enzyme concentrations is necessary for the diagnosis of RCM. Here we present an alternative microplate method that is based on a standard 96-well microplate format and microplate reader that simplify the quantification of NADH-CYB5R activity. TECAN (Infinite 200 PRO series) microplate reader with Tecan's proven Magellan™ software measured the NADH-CYB5R enzyme activity in 250 normal controls and previously diagnosed 25 cases of RCM due to NADH-CYB5R deficiency in the Indian population using 96-well microplates using 200 μl of total reaction mixture and also compared with standard spectrophotometric assay. We have also studied stability of the hemolysate stored at 4 and -20°C temperature. Enzyme activity in all 25 samples ranged from 6.09 to 10.07 IU/g Hb (mean ± SD: 8.08 ± 1.99 IU/g Hb) where as normal control ranged (n = 250) between 13.42 and 21.58 IU/g Hb) (mean ± SD: 17.5 ± 4.08 IU/g of Hb). Data obtained from the microplate reader were compared with standard spectrophotometer method and found 100% concordance using both methods. Microplate method allows differentiating between normal, deficient and intermediate enzyme activity. It was observed that samples had significant loss of activity when stored at 4°C and retained stable activity at -20°C for 1 week time. Our new method, incorporating a whole process of enzyme assay into a microplate format is readily applicable and allows rapid monitoring of enzyme assay. It is readily applicable to quantitative assay on pediatric sample as well as large number of samples for population screening.

  13. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    NASA Astrophysics Data System (ADS)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  14. [Chemical databases and virtual screening].

    PubMed

    Rognan, Didier; Bonnet, Pascal

    2014-12-01

    A prerequisite to any virtual screening is the definition of compound libraries to be screened. As we describe here, various sources are available. The selection of the proper library is usually project-dependent but at least as important as the screening method itself. This review details the main compound libraries that are available for virtual screening and guide the reader to the best possible selection according to its needs. © 2014 médecine/sciences – Inserm.

  15. Step-by-step guide to building an inexpensive 3D printed motorized positioning stage for automated high-content screening microscopy.

    PubMed

    Schneidereit, Dominik; Kraus, Larissa; Meier, Jochen C; Friedrich, Oliver; Gilbert, Daniel F

    2017-06-15

    High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl - - and Ca 2+ -imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Understanding the Nature and Impact of Young Readers' Literacy Interactions with Talking Books and during Adult Reading Support

    ERIC Educational Resources Information Center

    Wood, Clare; Pillinger, Claire; Jackson, Emma

    2010-01-01

    This paper reports an extended analysis of the study reported in [Wood, C. (2005). "Beginning readers' use of 'talking books' software can affect their reading strategies." "Journal of Research in Reading, 28," 170-182.], in which five and six-year-old children received either six sessions using specially designed talking books or six sessions of…

  17. Efficacy of a First-Grade Responsiveness-to-Intervention Prevention Model for Struggling Readers

    ERIC Educational Resources Information Center

    Gilbert, Jennifer K.; Compton, Donald L.; Fuchs, Douglas; Fuchs, Lynn S.; Bouton, Bobette; Barquero, Laura A.; Cho, Eunsoo

    2013-01-01

    This randomized control trial examined the efficacy of a multitiered supplemental tutoring program within a first-grade responsiveness-to-intervention prevention model. Struggling first-grade readers (n = 649) were screened and progress monitored at the start of the school year. Those identified as unresponsive to general education Tier 1 (n =…

  18. GEOSAT Follow-On (GFO) Altimeter Document Series. Volume 5; Version 1; GFO Radar Altimeter Processing at Wallops Flight Facility

    NASA Technical Reports Server (NTRS)

    Lockwood, Dennis W.; Conger, A. M.

    2003-01-01

    This document is a compendium of the WFF GFO Software Development Team's knowledge regarding of GDO CAL/VAL Data. It includes many elements of a requirements document, a software specification document, a software design document, and a user's guide. In the more technical sections, this document assumes the reader is familiar with GFO and its CAL/VAL Data.

  19. The “voice” has it: screen reader adoption and switching behavior among vision impaired persons in India

    PubMed Central

    Pal, Joyojeet; Cutrell, Edward

    2013-01-01

    We present results from a mixed methods study of screen reader use and switching behavior among people with vision impairments in India. We examine loyalty and experimentation with screen readers and find that the main drivers of adoption for early users differ significantly from the factors that drive continued use by advanced users. We discuss the factor that emerges as one of the strongest stated drivers of early adoption, TTS “voice” quality, particularly a “human-sounding voice” as one of the key features differentiating free/open source (FOSS) products from more expensive proprietary products. While the initial preferences are driven by voice quality, application support becomes more important over time as users speed up their sound settings and become more comfortable with the resultant non-human-sounding speech. We discuss these findings from two theoretical perspectives – first, through the application of the economics of behavior switching, and second, vis-à-vis novice and expert approaches toward new product adoption. We argue that these findings further our understanding of initial user comfort related to assistive technology adoption, and the impact of early technology choices on long-term technology switching behavior. PMID:24620705

  20. Breast cancers missed by screening radiologists can be detected by reading mammograms at a distance.

    PubMed

    Schreutelkamp, Ineke L; Kwee, Robert M; Veekmans, Peter; Adriaensen, Miraude E A P M

    2018-05-03

    During locally organized quality assurance evaluation sessions for screening radiologists, we noticed that individual screening radiologists did miss tumours which in our opinion could be detected at a distance. To determine whether tumours missed by individual screening radiologists can be detected at a distance. Twenty-eight screening mammograms of 28 females (mean age 63 years, range 49-73) with a pathologically proven malignant tumour missed by individual screening radiologists were mixed with 56 normal screening mammograms of 56 females (mean age 63 years, range 53-74). This test set was independently assessed by a senior screening radiologist and by a radiology resident without prior training in screening mammography at 1.5 m distance from the screen display. Readers were unaware of the prevalence of pathologically proven malignant tumours in the test set. Primary outcome was whether the reader would recall the woman. The senior screening radiologist recalled 28 of 28 women with a pathologically proven malignant tumour (sensitivity of 100%) and 16 of 56 women without pathology (specificity of 71%). The radiology resident recalled 25 of 28 women with a pathologically proven malignant tumour (sensitivity of 89%) and 10 of 56 women without pathology (specificity of 82%). Some malignant tumours missed by an individual screening radiologist can be detected from 1.5 m distance. Therefore, we recommend that screening radiologists consciously take a distant view before closely evaluating the mammogram in detail.

  1. Securing PCs and Data in Libraries and Schools: A Handbook with Menuing, Anti-Virus, and Other Protective Software.

    ERIC Educational Resources Information Center

    Benson, Allen C.

    This handbook is designed to help readers identify and eliminate security risks, with sound recommendations and library-tested security software. Chapter 1 "Managing Your Facilities and Assessing Your Risks" addresses fundamental management responsibilities including planning for a secure system, organizing computer-related information, assessing…

  2. Design, Development, and Testing of a Network Frequency Selection Service (NFSS)

    DTIC Science & Technology

    1994-02-14

    mercial simulation software (Sim++), word processor ( FrameMaker ), editor (Gnu Emacs), software ver- sion control (Revision Control System (RCS)), system...of FrameMaker ".mif" files. When viewed using FrameMaker or a PostScript reader, each page of results appears as two columns by four rows of graphics

  3. Implementation of a 5-Minute Magnetic Resonance Imaging Screening Protocol for Prostate Cancer in Men With Elevated Prostate-Specific Antigen Before Biopsy.

    PubMed

    Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios

    2018-03-01

    The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.

  4. In vivo imaging and quantitative analysis of changes in axon length using transgenic zebrafish embryos.

    PubMed

    Kanungo, Jyotshnabala; Lantz, Susan; Paule, Merle G

    2011-01-01

    We describe an imaging procedure to measure axon length in zebrafish embryos in vivo. Automated fluorescent image acquisition was performed with the ImageXpress Micro high content screening reader and further analysis of axon lengths was performed on archived images using AcuityXpress software. We utilized the Neurite Outgrowth Application module with a customized protocol (journal) to measure the axons. Since higher doses of ethanol (2-2.5%, v/v) have been shown to deform motor neurons and axons during development, here we used ethanol to treat transgenic [hb9:GFP (green fluorescent protein)] zebrafish embryos at 28 hpf (hours post-fertilization). These embryos express GFP in the motor neurons and their axons. Embryos after ethanol treatment were arrayed in 384-well plates for automated fluorescent image acquisition in vivo. Average axon lengths of high dose ethanol-treated embryos were significantly lower than the control. Another experiment showed that there was no significant difference in the axon lengths between the embryos grown for 24h at 22°C and 28.5°C. These test experiments demonstrate that using axon development as an end-point, compound screening can be performed in a time-efficient manner. Published by Elsevier Inc.

  5. HCS road: an enterprise system for integrated HCS data management and analysis.

    PubMed

    Jackson, Donald; Lenard, Michael; Zelensky, Alexander; Shaikh, Mohammad; Scharpf, James V; Shaginaw, Richard; Nawade, Mahesh; Agler, Michele; Cloutier, Normand J; Fennell, Myles; Guo, Qi; Wardwell-Swanson, Judith; Zhao, Dandan; Zhu, Yingjie; Miller, Christopher; Gill, James

    2010-08-01

    The effective analysis and interpretation of high-content screening (HCS) data requires joining results to information on experimental treatments and controls, normalizing data, and selecting hits or fitting concentration-response curves. HCS data have unique requirements that are not supported by traditional high-throughput screening databases, including the ability to designate separate positive and negative controls for different measurements in multiplexed assays; the ability to capture information on the cell lines, fluorescent reagents, and treatments in each assay; the ability to store and use individual-cell and image data; and the ability to support HCS readers and software from multiple vendors along with third-party image analysis tools. To address these requirements, the authors developed an enterprise system for the storage and processing of HCS images and results. This system, HCS Road, supports target identification, lead discovery, lead evaluation, and lead profiling activities. A dedicated client supports experimental design, data review, and core analyses and displays images together with results for assay development, hit assessment, and troubleshooting. Data can be exported to third-party applications for further analysis and exploration. HCS Road provides a single source for high-content results across the organization, regardless of the group or instrument that produced them.

  6. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    PubMed Central

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  7. Evaluation of a proximity card authentication system for health care settings.

    PubMed

    Fontaine, Jacqueline; Zheng, Kai; Van De Ven, Cosmas; Li, Huiyang; Hiner, James; Mitchell, Kathy; Gendler, Stephen; Hanauer, David A

    2016-08-01

    Multiple users access computer workstations in busy clinical settings, requiring many logins throughout the day as users switch from one computer to another. This can lead to workflow inefficiencies as well as security concerns resulting from users sharing login sessions to save time. Proximity cards and readers have the potential to improve efficiency and security by allowing users to access clinical workstations simply by bringing the card near the reader, without the need for manual entry of a username and password. To assess the perceived impact of proximity cards and readers for rapid user authentication to clinical workstations in the setting of an existing electronic health record with single sign-on software already installed. Questionnaires were administered to clinical faculty and staff five months before and three months after the installation of proximity card readers in an inpatient birthing center and an outpatient obstetrics clinic. Open-ended feedback was also collected and qualitatively analyzed. There were 71 and 33 responses to the pre- and post-implementation surveys, respectively. There was a significant increase in the perceived speed of login with the proximity cards, and a significant decrease in the self-reported occurrence of shared login sessions between users. Feedback regarding the system was mostly positive, although several caveats were noted, including minimal benefit when used with an obstetric application that did not support single sign-on. Proximity cards and readers, along with single sign-on software, have the potential to enhance workflow efficiency by allowing for faster login times and diminish security concerns by reducing shared logins on clinical workstations. The positive feedback was used by our health system leadership to support the expanded implementation of the proximity card readers throughout the clinical setting. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. The Effectiveness of Synthetic Phonics in the Development of Early Reading Skills among Struggling Young ESL Readers

    ERIC Educational Resources Information Center

    Jamaludin, Khairul Azhar; Alias, Norlidah; Mohd Khir, Roselina Johari; DeWitt, Dorothy; Kenayathula, Husaina Banu

    2016-01-01

    A quasi-experimental research design was used to investigate the effectiveness of synthetic phonics in the development of early reading skills among struggling young English as a second language (ESL) readers in a rural school. The pretest and posttest, adapted from the Phonological Awareness Literacy Screening (PALS) for Preschool Students and…

  9. Teleretinal screening for diabetic retinopathy in six Los Angeles urban safety-net clinics: initial findings.

    PubMed

    Ogunyemi, Omolola; Terrien, Elizabeth; Eccles, Alicia; Patty, Lauren; George, Sheba; Fish, Allison; Teklehaimanot, Senait; Ilapakurthi, Ramarao; Aimiuwu, Otaren; Baker, Richard

    2011-01-01

    Diabetic retinopathy is a leading cause of blindness in US adults. This paper presents initial results of a teleretinal screening project for diabetic retinopathy involving six Los Angeles safety net clinics. A total of 1,943 patients have been screened for diabetic retinopathy by three ophthalmologist readers, with 416 receiving a recommendation for referral to specialty care. Of the cases recommended for referral, 24 had proliferative diabetic retinopathy, 62 had severe non-proliferative diabetic retinopathy (NPDR), 60 had moderate NPDR, 19 had mild NPDR, 138 had a non-diabetic condition, such as glaucoma, 63 had clinically significant macular edema without retinopathy and 50 had non-gradable images. Between 3% and 12.2% of retinal images taken at the clinics were assessed by readers as inadequate for any interpretation. The study shows the feasibility and challenges of teleretinal screening for diabetic retinopathy in urban areas facing specialist shortages and an overburdened, under-resourced safety net care-delivery system.

  10. High content screening in microfluidic devices

    PubMed Central

    Cheong, Raymond; Paliwal, Saurabh; Levchenko, Andre

    2011-01-01

    Importance of the field Miniaturization is key to advancing the state-of-the-art in high content screening (HCS), in order to enable dramatic cost savings through reduced usage of expensive biochemical reagents and to enable large-scale screening on primary cells. Microfluidic technology offers the potential to enable HCS to be performed with an unprecedented degree of miniaturization. Areas covered in this review This perspective highlights a real-world example from the authors’ work of HCS assays implemented in a highly miniaturized microfluidic format. Advantages of this technology are discussed, including cost savings, high throughput screening on primary cells, improved accuracy, the ability to study complex time-varying stimuli, and ease of automation, integration, and scaling. What the reader will gain The reader will understand the capabilities of a new microfluidics-based platform for HCS, and the advantages it provides over conventional plate-based HCS. Take home message Microfluidics technology will drive significant advancements and broader usage and applicability of HCS in drug discovery. PMID:21852997

  11. Teleretinal Screening for Diabetic Retinopathy in Six Los Angeles Urban Safety-Net Clinics: Initial Findings

    PubMed Central

    Ogunyemi, Omolola; Terrien, Elizabeth; Eccles, Alicia; Patty, Lauren; George, Sheba; Fish, Allison; Teklehaimanot, Senait; Ilapakurthi, Ramarao; Aimiuwu, Otaren; Baker, Richard

    2011-01-01

    Diabetic retinopathy is a leading cause of blindness in US adults. This paper presents initial results of a teleretinal screening project for diabetic retinopathy involving six Los Angeles safety net clinics. A total of 1,943 patients have been screened for diabetic retinopathy by three ophthalmologist readers, with 416 receiving a recommendation for referral to specialty care. Of the cases recommended for referral, 24 had proliferative diabetic retinopathy, 62 had severe non-proliferative diabetic retinopathy (NPDR), 60 had moderate NPDR, 19 had mild NPDR, 138 had a non-diabetic condition, such as glaucoma, 63 had clinically significant macular edema without retinopathy and 50 had non-gradable images. Between 3% and 12.2% of retinal images taken at the clinics were assessed by readers as inadequate for any interpretation. The study shows the feasibility and challenges of teleretinal screening for diabetic retinopathy in urban areas facing specialist shortages and an overburdened, under-resourced safety net care-delivery system. PMID:22195163

  12. An Interactive and Automated Software Development Environment.

    DTIC Science & Technology

    1982-12-01

    four levels. Each DFD has an accompanying textual description to aid the reader in understanding the diagram. Both the data flows and the operations...students using the SDW for major software developments. Students in the software engineering courses use the SDW as a pedagogical tool for learning the...the SDWE. For thiz reason, the modified SDWE Algorithmic Design is included as Appendix F. 172 Ui 4.4 Desigin RL the ProQiect Data Baes The Project

  13. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.

    PubMed

    Mathieu, Kelsey B; Ai, Hua; Fox, Patricia S; Godoy, Myrna Cobos Barco; Munden, Reginald F; de Groot, Patricia M; Pan, Tinsu

    2014-03-06

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground-glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back-projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast-to-noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening.

  14. Automated extraction of chemical structure information from digital raster images

    PubMed Central

    Park, Jungkap; Rosania, Gus R; Shedden, Kerby A; Nguyen, Mandee; Lyu, Naesung; Saitou, Kazuhiro

    2009-01-01

    Background To search for chemical structures in research articles, diagrams or text representing molecules need to be translated to a standard chemical file format compatible with cheminformatic search engines. Nevertheless, chemical information contained in research articles is often referenced as analog diagrams of chemical structures embedded in digital raster images. To automate analog-to-digital conversion of chemical structure diagrams in scientific research articles, several software systems have been developed. But their algorithmic performance and utility in cheminformatic research have not been investigated. Results This paper aims to provide critical reviews for these systems and also report our recent development of ChemReader – a fully automated tool for extracting chemical structure diagrams in research articles and converting them into standard, searchable chemical file formats. Basic algorithms for recognizing lines and letters representing bonds and atoms in chemical structure diagrams can be independently run in sequence from a graphical user interface-and the algorithm parameters can be readily changed-to facilitate additional development specifically tailored to a chemical database annotation scheme. Compared with existing software programs such as OSRA, Kekule, and CLiDE, our results indicate that ChemReader outperforms other software systems on several sets of sample images from diverse sources in terms of the rate of correct outputs and the accuracy on extracting molecular substructure patterns. Conclusion The availability of ChemReader as a cheminformatic tool for extracting chemical structure information from digital raster images allows research and development groups to enrich their chemical structure databases by annotating the entries with published research articles. Based on its stable performance and high accuracy, ChemReader may be sufficiently accurate for annotating the chemical database with links to scientific research articles. PMID:19196483

  15. Making Visible the Coding Process: Using Qualitative Data Software in a Post-Structural Study

    ERIC Educational Resources Information Center

    Ryan, Mary

    2009-01-01

    Qualitative research methods require transparency to ensure the "trustworthiness" of the data analysis. The intricate processes of organising, coding and analysing the data are often rendered invisible in the presentation of the research findings, which requires a "leap of faith" for the reader. Computer assisted data analysis software can be used…

  16. Doing Qualitative Research Using Your Computer: A Practical Guide

    ERIC Educational Resources Information Center

    Hahn, Chris

    2008-01-01

    This book is a practical, hands-on guide to using commonly available everyday technology, including Microsoft software, to manage and streamline research projects. It uses straight-forward, everyday language to walk readers through this process, drawing on a wide range of examples to demonstrate how easy it is to use such software. This guide is…

  17. Estimating the monetary value of willingness to pay for E-book reader's attributes using partially confounded factorial conjoint choice experiment

    NASA Astrophysics Data System (ADS)

    Yong, Chin-Khian

    2013-09-01

    A partially confounded factorial conjoint choice experiments design was used to examine the monetary value of the willingness to pay for E-book Reader's attributes. Conjoint analysis is an efficient, cost-effective, and most widely used quantitative method in marketing research to understand consumer preferences and value trade-off. Value can be interpreted by customer or consumer as the received of multiple benefits from a price that was paid. The monetary value of willingness to pay for battery life, internal memory, external memory, screen size, text to Speech, touch screen, and converting handwriting to digital text of E-book reader were estimated in this study. Due to the significant interaction effect of the attributes with the price, the monetary values for the seven attributes were found to be different at different values of odds of purchasing versus not purchasing. The significant interactions effects were one of the main contribution of the partially confounded factorial conjoint choice experiment.

  18. How Strong and Weak Readers Perform on the Developmental Eye Movement Test (DEM): Norms for Latvian School-Aged Children

    ERIC Educational Resources Information Center

    Serdjukova, Jelena; Ekimane, Lasma; Valeinis, Janis; Skilters, Jurgis; Krumina, Gunta

    2017-01-01

    The aim of our study was to determine DEM test performance norms for school-aged children in Latvia, assess how DEM test results correlate with children's reading rates, compare test performance between strong and weak readers. A modified DEM test and a newly developed reading test were administered to 1487 children during a screening survey. Our…

  19. Teleretinal screening for diabetic retinopathy in six Los Angeles urban safety-net clinics: final study results.

    PubMed

    Ogunyemi, Omolola; George, Sheba; Patty, Lauren; Teklehaimanot, Senait; Baker, Richard

    2013-01-01

    In a previous paper, we presented initial findings from a study on the feasibility and challenges of implementing teleretinal screening for diabetic retinopathy in an urban safety net setting facing eyecare specialist shortages. This paper presents some final results from that study, which involved six South Los Angeles safety net clinics. A total of 2,732 unique patients were screened for diabetic retinopathy by three ophthalmologist readers, with 1035 receiving a recommendation for referral to specialty care. Referrals included 48 for proliferative diabetic retinopathy, 115 for severe non-proliferative diabetic retinopathy (NPDR), 247 for moderate NPDR, 246 for mild NPDR, 97 for clinically significant macular edema, and 282 for a non-diabetic condition, such as glaucoma. Image quality was also assessed, with ophthalmologist readers grading 4% to 13% of retinal images taken at the different clinics as being inadequate for any diagnostic interpretation.

  20. Teleretinal Screening for Diabetic Retinopathy in Six Los Angeles Urban Safety-Net Clinics: Final Study Results

    PubMed Central

    Ogunyemi, Omolola; George, Sheba; Patty, Lauren; Teklehaimanot, Senait; Baker, Richard

    2013-01-01

    In a previous paper, we presented initial findings from a study on the feasibility and challenges of implementing teleretinal screening for diabetic retinopathy in an urban safety net setting facing eyecare specialist shortages. This paper presents some final results from that study, which involved six South Los Angeles safety net clinics. A total of 2,732 unique patients were screened for diabetic retinopathy by three ophthalmologist readers, with 1035 receiving a recommendation for referral to specialty care. Referrals included 48 for proliferative diabetic retinopathy, 115 for severe non-proliferative diabetic retinopathy (NPDR), 247 for moderate NPDR, 246 for mild NPDR, 97 for clinically significant macular edema, and 282 for a non-diabetic condition, such as glaucoma. Image quality was also assessed, with ophthalmologist readers grading 4% to 13% of retinal images taken at the different clinics as being inadequate for any diagnostic interpretation. PMID:24551394

  1. Diagnosing Dyslexia: The Screening of Auditory Laterality.

    ERIC Educational Resources Information Center

    Johansen, Kjeld

    A study investigated whether a correlation exists between the degree and nature of left-brain laterality and specific reading and spelling difficulties. Subjects, 50 normal readers and 50 reading disabled persons native to the island of Bornholm, had their auditory laterality screened using pure-tone audiometry and dichotic listening. Results…

  2. A smartphone colorimetric reader integrated with an ambient light sensor and a 3D printed attachment for on-site detection of zearalenone.

    PubMed

    Chen, Yuan; Fu, Qiangqiang; Li, Dagang; Xie, Jun; Ke, Dongxu; Song, Qifang; Tang, Yong; Wang, Hong

    2017-11-01

    Smartphone biosensors could be cost-effective, portable instruments to be used for the readout of liquid colorimetric assays. However, current reported smartphone colorimetric readers have relied on photos of liquid assays captured using a camera, and then analyzed using software programs. This approach results in a relatively low accuracy and low generality. In this work, we reported a novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays. The portable and low-cost ($0.15) reader utilized a simplified electronic and light path design. Furthermore, our reported smartphone colorimetric reader can be compatible with different smartphones. As a proof of principle, the utility of this device was demonstrated using it in conjunction with an enzyme-linked immunosorbent assay to detect zearalenone. Results were consistent with those obtained using a professional microplate reader. The developed smartphone colorimetric reader was capable of providing scalable, cost-effective, and accurate results for liquid colorimetric assays that related to clinical diagnoses, environment pollution, and food testing. Graphical abstract A novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays.

  3. Graphical Methods: A Review of Current Methods and Computer Hardware and Software. Technical Report No. 27.

    ERIC Educational Resources Information Center

    Bessey, Barbara L.; And Others

    Graphical methods for displaying data, as well as available computer software and hardware, are reviewed. The authors have emphasized the types of graphs which are most relevant to the needs of the National Center for Education Statistics (NCES) and its readers. The following types of graphs are described: tabulations, stem-and-leaf displays,…

  4. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines

    PubMed Central

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-01-01

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines. PMID:28837058

  5. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study

    PubMed Central

    Mathieu, Kelsey B.; Ai, Hua; Fox, Patricia S.; Godoy, Myrna Cobos Barco; Munden, Reginald F.; de Groot, Patricia M.

    2014-01-01

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground‐glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model‐based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back‐projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast‐to‐noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening. PACS numbers: 87.57.Q‐, 87.57.nf PMID:24710436

  6. Screen Design Principles of Computer-Aided Instructional Software for Elementary School Students

    ERIC Educational Resources Information Center

    Berrin, Atiker; Turan, Bülent Onur

    2017-01-01

    This study aims to present primary school students' views about current educational software interfaces, and to propose principles for educational software screens. The study was carried out with a general screening model. Sample group of the study consisted of sixth grade students in Sehit Ögretmen Hasan Akan Elementary School. In this context,…

  7. Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules.

    PubMed

    Milanese, Gianluca; Eberhard, Matthias; Martini, Katharina; Vittoria De Martini, Ilaria; Frauenfelder, Thomas

    2018-04-01

    To evaluate whether vessel-suppressed computed tomography (VSCT) can be reliably used for semi-automated volumetric measurements of solid pulmonary nodules, as compared to standard CT (SCT) MATERIAL AND METHODS: Ninety-three SCT were elaborated by dedicated software (ClearRead CT, Riverain Technologies, Miamisburg, OH, USA), that allows subtracting vessels from lung parenchyma. Semi-automated volumetric measurements of 65 solid nodules were compared between SCT and VSCT. The measurements were repeated by two readers. For each solid nodule, volume measured on SCT by Reader 1 and Reader 2 was averaged and the average volume between readers acted as standard of reference value. Concordance between measurements was assessed using Lin's Concordance Correlation Coefficient (CCC). Limits of agreement (LoA) between readers and CT datasets were evaluated. Standard of reference nodule volume ranged from 13 to 366 mm 3 . The mean overestimation between readers was 3 mm 3 and 2.9 mm 3 on SCT and VSCT, respectively. Semi-automated volumetric measurements on VSCT showed substantial agreement with the standard of reference (Lin's CCC = 0.990 for Reader 1; 0.985 for Reader 2). The upper and lower LoA between readers' measurements were (16.3, -22.4 mm 3 ) and (15.5, -21.4 mm 3 ) for SCT and VSCT, respectively. VSCT datasets are feasible for the measurements of solid nodules, showing an almost perfect concordance between readers and with measurements on SCT. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Reader performance in visual assessment of breast density using visual analogue scales: Are some readers more predictive of breast cancer?

    NASA Astrophysics Data System (ADS)

    Rayner, Millicent; Harkness, Elaine F.; Foden, Philip; Wilson, Mary; Gadde, Soujanya; Beetles, Ursula; Lim, Yit Y.; Jain, Anil; Bundred, Sally; Barr, Nicky; Evans, D. Gareth; Howell, Anthony; Maxwell, Anthony; Astley, Susan M.

    2018-03-01

    Mammographic breast density is one of the strongest risk factors for breast cancer, and is used in risk prediction and for deciding appropriate imaging strategies. In the Predicting Risk Of Cancer At Screening (PROCAS) study, percent density estimated by two readers on Visual Analogue Scales (VAS) has shown a strong relationship with breast cancer risk when assessed against automated methods. However, this method suffers from reader variability. This study aimed to assess the performance of PROCAS readers using VAS, and to identify those most predictive of breast cancer. We selected the seven readers who had estimated density on over 6,500 women including at least 100 cancer cases, analysing their performance using multivariable logistic regression and Receiver Operator Characteristic (ROC) analysis. All seven readers showed statistically significant odds ratios (OR) for cancer risk according to VAS score after adjusting for classical risk factors. The OR was greatest for reader 18 at 1.026 (95% Cl 1.018-1.034). Adjusted Area Under the ROC Curves (AUCs) were statistically significant for all readers, but greatest for reader 14 at 0.639. Further analysis of the VAS scores for these two readers showed reader 14 had higher sensitivity (78.0% versus 42.2%), whereas reader 18 had higher specificity (78.0% versus 46.0%). Our results demonstrate individual differences when assigning VAS scores; one better identified those with increased risk, whereas another better identified low risk individuals. However, despite their different strengths, both readers showed similar predictive abilities overall. Standardised training for VAS may improve reader variability and consistency of VAS scoring.

  9. Formal Methods for Life-Critical Software

    NASA Technical Reports Server (NTRS)

    Butler, Ricky W.; Johnson, Sally C.

    1993-01-01

    The use of computer software in life-critical applications, such as for civil air transports, demands the use of rigorous formal mathematical verification procedures. This paper demonstrates how to apply formal methods to the development and verification of software by leading the reader step-by-step through requirements analysis, design, implementation, and verification of an electronic phone book application. The current maturity and limitations of formal methods tools and techniques are then discussed, and a number of examples of the successful use of formal methods by industry are cited.

  10. Provider software buyer's guide.

    PubMed

    1994-03-01

    To help long term care providers find new ways to improve quality of care and efficiency, Provider magazine presents the fourth annual listing of software firms marketing computer programs for all areas of nursing facility operations. On the following five pages, more than 80 software firms display their wares, with programs such as minimum data set and care planning, dietary, accounting and financials, case mix, and medication administration records. The guide also charts compatible hardware, integration ability, telephone numbers, company contacts, and easy-to-use reader service numbers.

  11. 5th Annual Provider Software Buyer's Guide.

    PubMed

    1995-03-01

    To help long term care providers find new ways to improve quality of care and efficiency, PROVIDER presents the fifth annual listing of software firms marketing computer programs for all areas of long term care operations. On the following five pages, more than 70 software firms display their wares, with programs such as minimum data set and care planning, dietary, accounting and financials, case mix, and medication administration records. The guide also charts compatible hardware, integration ability, telephone numbers, company contacts, and easy-to-use reader service numbers.

  12. Provider software buyer's guide.

    PubMed

    1993-03-01

    To help long term care providers find new ways to improve quality of care and efficiency. Provider magazine presents the third annual listing of software firms marketing computer programs for all areas of nursing facility operations. On the following five pages, more than 80 software firms display their wares, with programs such as minimum data set and care planning, dietary, accounting and financials, case mix, and medication administration records. The guide also charts compatible hardware, integration ability, telephone numbers, company contacts, and easy-to-use reader service numbers.

  13. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Westmead Breast Cancer Institute, Westmead, New South Wales

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed toolmore » applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.« less

  14. Benefits of Automatic Duplexing Fact Sheet

    EPA Pesticide Factsheets

    This resource provides a how-to duplex guide, informs the reader on the benefits and cost savings from automatic duplexing, and several off the shelf print management software options for your facility.

  15. Screening for Breast Cancer.

    PubMed

    Niell, Bethany L; Freer, Phoebe E; Weinfurtner, Robert Jared; Arleo, Elizabeth Kagan; Drukteinis, Jennifer S

    2017-11-01

    The goal of screening is to detect breast cancers when still curable to decrease breast cancer-specific mortality. Breast cancer screening in the United States is routinely performed with mammography, supplemental digital breast tomosynthesis, ultrasound, and/or MR imaging. This article aims to review the most commonly used breast imaging modalities for screening, discuss how often and when to begin screening with specific imaging modalities, and examine the pros and cons of screening. By the article's end, the reader will be better equipped to have informed discussions with patients and medical professionals regarding the benefits and disadvantages of breast cancer screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Breast screening: What can the interval cancer review teach us? Are we perhaps being a bit too hard on ourselves?

    PubMed

    Lekanidi, Katerina; Dilks, Phil; Suaris, Tamara; Kennett, Steffan; Purushothaman, Hema

    2017-09-01

    The aim of this study was to determine the features that make interval cancers apparent on the preceding screening mammogram and determine whether changes in the ways of performing the interval cancer review will affect the true interval cancer rate. This study was approved by the clinical governance committee. Mammograms of women diagnosed with an interval cancer were included in the study if they had been allocated to either the "suspicious signs" group or "subtle signs" group, during the historic interval cancer review. Three radiologists, individually and blinded to the site of interval cancer, reviewed the mammograms and documented the presence, site, characteristics and classification of any abnormality. Findings were compared with the appearances of the abnormality at the site of subsequent cancer development by a different breast radiologist. The chi-squared test was used in the analysis of the results, seeking associations between recall concordance and cancer mammographic or histological characteristics. 111/590 interval cancers fulfilled the study inclusion criteria. In 17% of the cases none of the readers identified the relevant abnormality on the screening mammogram. 1/3 readers identified the relevant lesion in 22% of the cases, 2/3 readers in 28% of cases and all 3 readers in 33% of cases. The commonest unanimously recalled abnormality was microcalcification and the most challenging mammographic abnormality to detect was asymmetric density. We did not find any statistically significant association between recall concordance and time to interval cancer, position of lesion in the breast, breast density or cancer grade. Even the simple step of performing an independent blinded review of interval cancers reduces the rate of interval cancers classified as missed by up to 39%. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Variable size computer-aided detection prompts and mammography film reader decisions

    PubMed Central

    Gilbert, Fiona J; Astley, Susan M; Boggis, Caroline RM; McGee, Magnus A; Griffiths, Pamela M; Duffy, Stephen W; Agbaje, Olorunsola F; Gillan, Maureen GC; Wilson, Mary; Jain, Anil K; Barr, Nicola; Beetles, Ursula M; Griffiths, Miriam A; Johnson, Jill; Roberts, Rita M; Deans, Heather E; Duncan, Karen A; Iyengar, Geeta

    2008-01-01

    Introduction The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision. Methods Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests. Results There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05). Conclusions For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision. PMID:18724867

  18. Variable size computer-aided detection prompts and mammography film reader decisions.

    PubMed

    Gilbert, Fiona J; Astley, Susan M; Boggis, Caroline Rm; McGee, Magnus A; Griffiths, Pamela M; Duffy, Stephen W; Agbaje, Olorunsola F; Gillan, Maureen Gc; Wilson, Mary; Jain, Anil K; Barr, Nicola; Beetles, Ursula M; Griffiths, Miriam A; Johnson, Jill; Roberts, Rita M; Deans, Heather E; Duncan, Karen A; Iyengar, Geeta

    2008-01-01

    The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision. Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests. There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05). For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision.

  19. [Prenatal risk calculation: comparison between Fast Screen pre I plus software and ViewPoint software. Evaluation of the risk calculation algorithms].

    PubMed

    Morin, Jean-François; Botton, Eléonore; Jacquemard, François; Richard-Gireme, Anouk

    2013-01-01

    The Fetal medicine foundation (FMF) has developed a new algorithm called Prenatal Risk Calculation (PRC) to evaluate Down syndrome screening based on free hCGβ, PAPP-A and nuchal translucency. The peculiarity of this algorithm is to use the degree of extremeness (DoE) instead of the multiple of the median (MoM). The biologists measuring maternal seric markers on Kryptor™ machines (Thermo Fisher Scientific) use Fast Screen pre I plus software for the prenatal risk calculation. This software integrates the PRC algorithm. Our study evaluates the data of 2.092 patient files of which 19 show a fœtal abnormality. These files have been first evaluated with the ViewPoint software based on MoM. The link between DoE and MoM has been analyzed and the different calculated risks compared. The study shows that Fast Screen pre I plus software gives the same risk results as ViewPoint software, but yields significantly fewer false positive results.

  20. Alternatives for Developing User Documentation for Applications Software

    DTIC Science & Technology

    1991-09-01

    style that is designed to match adult reading behaviors, using reader-based writing techniques, developing effective graphics , creating reference aids...involves research, analysis, design , and testing. The writer must have a solid understanding of the technical aspects of the document being prepared, good...ABSTRACT The preparation of software documentation is an iterative process that involves research, analysis, design , and testing. The writer must have

  1. Development of a national electronic interval cancer review for breast screening

    NASA Astrophysics Data System (ADS)

    Halling-Brown, M. D.; Patel, M. N.; Wallis, M. G.; Young, K. C.

    2018-03-01

    Reviewing interval cancers and prior screening mammograms are a key measure to monitor screening performance. Radiological analysis of the imaging features in prior mammograms and retrospective classification are an important educational tool for readers to improve individual performance. The requirements of remote, collaborative image review sessions, such as those required to run a remote interval cancer review, are variable and demand a flexible and configurable software solution that is not currently available on commercial workstations. The wide range of requirements for both collection and remote review of interval cancers has precipitated the creation of extensible medical image viewers and accompanying systems. In order to allow remote viewing, an application has been designed to allow workstation-independent, PACS-less viewing and interaction with medical images in a remote, collaborative manner, providing centralised reporting and web-based feedback. A semi-automated process, which allows the centralisation of interval cancer cases, has been developed. This stand-alone, flexible image collection toolkit provides the extremely important function of bespoke, ad-hoc image collection at sites where there is no dedicated hardware. Web interfaces have been created which allow a national or regional administrator to organise, coordinate and administer interval cancer review sessions and deploy invites to session members to participate. The same interface allows feedback to be analysed and distributed. The eICR provides a uniform process for classifying interval cancers across the NHSBSP, which facilitates rapid access to a robust 'external' review for patients and their relatives seeking answers about why their cancer was 'missed'.

  2. Initial clinical results with a new needle screen storage phosphor system in chest radiograms.

    PubMed

    Körner, M; Wirth, S; Treitl, M; Reiser, M; Pfeifer, K-J

    2005-11-01

    To evaluate image quality and anatomical detail depiction in dose-reduced digital plain chest radiograms using a new needle screen storage phosphor (NIP) in comparison to full dose conventional powder screen storage phosphor (PIP) images. 24 supine chest radiograms were obtained with PIP at standard dose and compared to follow-up studies of the same patients obtained with NIP with dose reduced to 50 % of the PIP dose (all imaging systems: AGFA-Gevaert, Mortsel, Belgium). In both systems identical versions of post-processing software supplied by the manufacturer were used with matched parameters. Six independent readers blinded to both modality and dose evaluated the images for depiction and differentiation of defined anatomical regions (peripheral lung parenchyma, central lung parenchyma, hilum, heart, diaphragm, upper mediastinum, and bone). All NIP images were compared to the corresponding PIP images using a five-point scale (- 2, clearly inferior to + 2, clearly superior). Overall image quality was rated for each PIP and NIP image separately (1, not usable to 5, excellent). PIP and dose reduced NIP images were rated equivalent. Mean image noise impression was only slightly higher on NIP images. Mean image quality for NIP showed no significant differences (p > 0.05, Mann-Whitney U test). With the use of the new needle structured storage phosphors in chest radiography, dose reduction of up to 50 % is possible without detracting from image quality or detail depiction. Especially in patients with multiple follow-up studies the overall dose can be decreased significantly.

  3. SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souri, S; Ahmed, Y; Cao, Y

    2014-06-15

    Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, amore » pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.« less

  4. Building a virtual ligand screening pipeline using free software: a survey.

    PubMed

    Glaab, Enrico

    2016-03-01

    Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. © The Author 2015. Published by Oxford University Press.

  5. Building a virtual ligand screening pipeline using free software: a survey

    PubMed Central

    2016-01-01

    Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. PMID:26094053

  6. A comparison of ROC inferred from FROC and conventional ROC

    NASA Astrophysics Data System (ADS)

    McEntee, Mark F.; Littlefair, Stephen; Pietrzyk, Mariusz W.

    2014-03-01

    This study aims to determine whether receiver operating characteristic (ROC) scores inferred from free-response receiver operating characteristic (FROC) were equivalent to conventional ROC scores for the same readers and cases. Forty-five examining radiologists of the American Board of Radiology independently reviewed 47 PA chest radiographs under at least two conditions. Thirty-seven cases had abnormal findings and 10 cases had normal findings. Half the readers were asked to first locate any visualized lung nodules, mark them and assign a level of confidence [the FROC mark-rating pair] and second give an overall to the entire image on the same scale [the ROC score]. The second half of readers gave the ROC rating first followed by the FROC mark-rating pairs. A normal image was represented with number 1 and malignant lesions with numbers 2-5. A jackknife free-response receiver operating characteristic (JAFROC), and inferred ROC (infROC) was calculated from the mark-rating pairs using JAFROC V4.1 software. ROC based on the overall rating of the image calculated using DBM MRMC software, which was also used to compare infROC and ROC AUCs treating the methods as modalities. Pearson's correlations coefficient and linear regression were used to examine their relationship using SPSS, version 21.0; (SPSS, Chicago, IL). The results of this study showed no significant difference between the ROC and Inferred ROC AUCs (p≤0.25). While Pearson's correlation coefficient was 0.7 (p≤0.01). Inter-reader correlation calculated from Obuchowski- Rockette covariance's ranged from 0.43-0.86 while intra-reader agreement was greater than previously reported ranging from 0.68-0.82.

  7. Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests.

    PubMed

    Obuchowski, N A

    2001-10-15

    Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement. Copyright 2001 John Wiley & Sons, Ltd.

  8. [Physiological and hygienic assessment of perception of the information from electronic device for reading (reader)].

    PubMed

    Kuchma, V R; Teksheva, L M; Vyatleva, O A; Kurgansky, A M

    2013-01-01

    A comparison of the legibility of the three different media: paper personal computer (LCD) and the e-reader in schoolchildren (12-14 years of age) was performed. Comprehensive assessment of the reading performance (speed of reading aloud, the number of errors in reading, and integral indicator of the degree of difficulty of visual task), its physiological value (according to data of EEG, EOG and ECG), and subjective preference of type of media by the schoolchildren showed that by the sum of signs e-reader occupies an intermediate position between printed text and the computer screen. The effect of increased emotional intensity of using e-reader (increased motivation), which is manifested in the preservation of the sympathetic nervous system activation after the reading, was obtained. The necessity of additional research has been shown.

  9. Factors Affecting the Reading Media Used by Visually Impaired Adults

    ERIC Educational Resources Information Center

    Goudiras, Dimitrios B.; Papadopoulos, Konstantinos S.; Koutsoklenis, Athanasios Ch.; Papageorgiou, Virginia E.; Stergiou, Maria S.

    2009-01-01

    The aim of this study was to examine reading media (braille, cassettes, screen-reader, screen-magnifier, large print, low vision aids, CCTV) used by visually impaired adults. This article reports the results of a research project involving 100 people with visual impairment. The participants were interviewed and asked to fill in a questionnaire to…

  10. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    PubMed

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  11. XGAP: a uniform and extensible data model and software platform for genotype and phenotype experiments

    PubMed Central

    2010-01-01

    We present an extensible software model for the genotype and phenotype community, XGAP. Readers can download a standard XGAP (http://www.xgap.org) or auto-generate a custom version using MOLGENIS with programming interfaces to R-software and web-services or user interfaces for biologists. XGAP has simple load formats for any type of genotype, epigenotype, transcript, protein, metabolite or other phenotype data. Current functionality includes tools ranging from eQTL analysis in mouse to genome-wide association studies in humans. PMID:20214801

  12. XGAP: a uniform and extensible data model and software platform for genotype and phenotype experiments.

    PubMed

    Swertz, Morris A; Velde, K Joeri van der; Tesson, Bruno M; Scheltema, Richard A; Arends, Danny; Vera, Gonzalo; Alberts, Rudi; Dijkstra, Martijn; Schofield, Paul; Schughart, Klaus; Hancock, John M; Smedley, Damian; Wolstencroft, Katy; Goble, Carole; de Brock, Engbert O; Jones, Andrew R; Parkinson, Helen E; Jansen, Ritsert C

    2010-01-01

    We present an extensible software model for the genotype and phenotype community, XGAP. Readers can download a standard XGAP (http://www.xgap.org) or auto-generate a custom version using MOLGENIS with programming interfaces to R-software and web-services or user interfaces for biologists. XGAP has simple load formats for any type of genotype, epigenotype, transcript, protein, metabolite or other phenotype data. Current functionality includes tools ranging from eQTL analysis in mouse to genome-wide association studies in humans.

  13. Double reading.

    PubMed

    Kopans, D B

    2000-07-01

    Clearly, the cost of double reading varies with the approach used. The Massachusetts General Hospital method can only lead to an increase in recalls and the costs that these engender (anxiety for the women recalled, trauma from any biopsies obtained, and the actual monetary costs of additional imaging and interventions). It is of interest that one potential cost, the concern that women recalled may be reluctant to participate again in screening, does not seem to be the case. Women who are recalled appear to be more likely to participate in future screening. Double interpretation where there must be a consensus between the interpreting radiologists, and if this cannot be reached a third arbiter, is the most labor intensive, but can reduce the number of recalls in a double reading system. Computer systems have been developed to act as a second reader. The films must be digitized and then fed through the reader, but studies suggest that the computer can identify cancers that may be overlooked by a human reader. The challenge is to do this without too many false-positive calls. If the radiologist finds the false-positives are too numerous and distracting, then the system is not used. As digital mammographic systems proliferate, and computer algorithms become more sophisticated, the second human reader will likely be replaced by a computer-aided detection system and double reading will become the norm.

  14. ONRASIA Scientific Information Bulletin. Volume 17, Number 4, October-December 1992

    DTIC Science & Technology

    1992-12-01

    Corporate Software Planning Oki’s Software Improvement Environment and Engineering Div. Strategy - Effective Management - Improvement of Informa- Mr...a CCITT-supported implementation phase. -- David K fore we have effectively implemented ISO Standard high-level language Kahaner, ONRASIA them...power with a system fo- putation) Result cused on their specific needs. Result Effective speed should be (Readers can write to me or to 150 times VP-400

  15. Attacking Software Crisis: A Macro Approach.

    DTIC Science & Technology

    1985-03-01

    Advisor X0774R.. Dyns, Second Reader W.R. Greer r. armn, Department of AAministrative Sciences Kneale rf. mrh- Dean of Information and Policy siences ...was at least originally intended to have practical value, that is, to satisfy some real need. Even the recent wave of game software for microcomputer...Comparing Online an" Offline Programming Performance, Communications of the ACM, January, 1968. 31. Schwartz, ,J. "Analyzing Large-Scale System

  16. Parallel Worlds: Agile and Waterfall Differences and Similarities

    DTIC Science & Technology

    2013-10-01

    development model , and it is deliberately shorter than the Agile Overview as most readers are assumed to be from the Traditional World. For a more in...process of DODI 5000 does not forbid the iterative incremental software development model with frequent end-user interaction, it requires heroics on...added). Today, many of the DOD’s large IT programs therefore continue to adopt program structures and software development models closely

  17. Selecting At-Risk First-Grade Readers for Early Intervention: Eliminating False Positives and Exploring the Promise of a Two-Stage Gated Screening Process

    ERIC Educational Resources Information Center

    Compton, Donald L.; Fuchs, Douglas; Fuchs, Lynn S.; Bouton, Bobette; Gilbert, Jennifer K.; Barquero, Laura A.; Cho, Eunsoo; Crouch, Robert C.

    2010-01-01

    The purposes of this study were (a) to identify measures that when added to a base 1st-grade screening battery help eliminate false positives and (b) to investigate gains in efficiency associated with a 2-stage gated screening procedure. We tested 355 children in the fall of 1st grade and assessed for reading difficulty at the end of 2nd grade.…

  18. Exploiting PubChem for Virtual Screening

    PubMed Central

    Xie, Xiang-Qun

    2011-01-01

    Importance of the field PubChem is a public molecular information repository, a scientific showcase of the NIH Roadmap Initiative. The PubChem database holds over 27 million records of unique chemical structures of compounds (CID) derived from nearly 70 million substance depositions (SID), and contains more than 449,000 bioassay records with over thousands of in vitro biochemical and cell-based screening bioassays established, with targeting more than 7000 proteins and genes linking to over 1.8 million of substances. Areas covered in this review This review builds on recent PubChem-related computational chemistry research reported by other authors while providing readers with an overview of the PubChem database, focusing on its increasing role in cheminformatics, virtual screening and toxicity prediction modeling. What the reader will gain These publicly available datasets in PubChem provide great opportunities for scientists to perform cheminformatics and virtual screening research for computer-aided drug design. However, the high volume and complexity of the datasets, in particular the bioassay-associated false positives/negatives and highly imbalanced datasets in PubChem, also creates major challenges. Several approaches regarding the modeling of PubChem datasets and development of virtual screening models for bioactivity and toxicity predictions are also reviewed. Take home message Novel data-mining cheminformatics tools and virtual screening algorithms are being developed and used to retrieve, annotate and analyze the large-scale and highly complex PubChem biological screening data for drug design. PMID:21691435

  19. Pilot Study of an Open-source Image Analysis Software for Automated Screening of Conventional Cervical Smears.

    PubMed

    Sanyal, Parikshit; Ganguli, Prosenjit; Barui, Sanghita; Deb, Prabal

    2018-01-01

    The Pap stained cervical smear is a screening tool for cervical cancer. Commercial systems are used for automated screening of liquid based cervical smears. However, there is no image analysis software used for conventional cervical smears. The aim of this study was to develop and test the diagnostic accuracy of a software for analysis of conventional smears. The software was developed using Python programming language and open source libraries. It was standardized with images from Bethesda Interobserver Reproducibility Project. One hundred and thirty images from smears which were reported Negative for Intraepithelial Lesion or Malignancy (NILM), and 45 images where some abnormality has been reported, were collected from the archives of the hospital. The software was then tested on the images. The software was able to segregate images based on overall nuclear: cytoplasmic ratio, coefficient of variation (CV) in nuclear size, nuclear membrane irregularity, and clustering. 68.88% of abnormal images were flagged by the software, as well as 19.23% of NILM images. The major difficulties faced were segmentation of overlapping cell clusters and separation of neutrophils. The software shows potential as a screening tool for conventional cervical smears; however, further refinement in technique is required.

  20. Patent review.

    PubMed

    Roy, Anuradha

    2011-05-01

    The section on patent review will be focused in the areas of interest to the readers of CCHTS. The search was conducted using the following key words: combinatorial chemistry, high throughput screening, drug repurposing, chemical library, high content screening, drug discovery and natural products. All patents highlighted here are identified by the patent number issued either by the World Intellectual Property Organization or by a regional patent office.

  1. Patent review.

    PubMed

    Roy, Anuradha; McGee, James E

    2011-08-01

    The section on patent review will be focused in the areas of interest to the readers of CCHTS. The search was conducted using the following key words: combinatorial chemistry, high throughput screening, drug repurposing, chemical library, high content screening, drug discovery and natural products. All patents highlighted here are identified by the patent number issued either by the World Intellectual Property Organization or by a regional patent office.

  2. Analysis of components of variance in multiple-reader studies of computer-aided diagnosis with different tasks

    NASA Astrophysics Data System (ADS)

    Beiden, Sergey V.; Wagner, Robert F.; Campbell, Gregory; Metz, Charles E.; Chan, Heang-Ping; Nishikawa, Robert M.; Schnall, Mitchell D.; Jiang, Yulei

    2001-06-01

    In recent years, the multiple-reader, multiple-case (MRMC) study paradigm has become widespread for receiver operating characteristic (ROC) assessment of systems for diagnostic imaging and computer-aided diagnosis. We review how MRMC data can be analyzed in terms of the multiple components of the variance (case, reader, interactions) observed in those studies. Such information is useful for the design of pivotal studies from results of a pilot study and also for studying the effects of reader training. Recently, several of the present authors have demonstrated methods to generalize the analysis of multiple variance components to the case where unaided readers of diagnostic images are compared with readers who receive the benefit of a computer assist (CAD). For this case it is necessary to model the possibility that several of the components of variance might be reduced when readers incorporate the computer assist, compared to the unaided reading condition. We review results of this kind of analysis on three previously published MRMC studies, two of which were applications of CAD to diagnostic mammography and one was an application of CAD to screening mammography. The results for the three cases are seen to differ, depending on the reader population sampled and the task of interest. Thus, it is not possible to generalize a particular analysis of variance components beyond the tasks and populations actually investigated.

  3. Artefacts found in computed radiography.

    PubMed

    Cesar, L J; Schueler, B A; Zink, F E; Daly, T R; Taubel, J P; Jorgenson, L L

    2001-02-01

    Artefacts on radiographic images are distracting and may compromise accurate diagnosis. Although most artefacts that occur in conventional radiography have become familiar, computed radiography (CR) systems produce artefacts that differ from those found in conventional radiography. We have encountered a variety of artefacts in CR images that were produced from four different models plate reader. These artefacts have been identified and traced to the imaging plate, plate reader, image processing software or laser printer or to operator error. Understanding the potential sources of CR artefacts will aid in identifying and resolving problems quickly and help prevent future occurrences.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarez, P; Gonzalez, S; McDonald, L

    Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE).more » The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.« less

  5. ConfocalVR: Immersive Visualization Applied to Confocal Microscopy.

    PubMed

    Stefani, Caroline; Lacy-Hulbert, Adam; Skillman, Thomas

    2018-06-24

    ConfocalVR is a virtual reality (VR) application created to improve the ability of researchers to study the complexity of cell architecture. Confocal microscopes take pictures of fluorescently labeled proteins or molecules at different focal planes to create a stack of 2D images throughout the specimen. Current software applications reconstruct the 3D image and render it as a 2D projection onto a computer screen where users need to rotate the image to expose the full 3D structure. This process is mentally taxing, breaks down if you stop the rotation, and does not take advantage of the eye's full field of view. ConfocalVR exploits consumer-grade virtual reality (VR) systems to fully immerse the user in the 3D cellular image. In this virtual environment the user can: 1) adjust image viewing parameters without leaving the virtual space, 2) reach out and grab the image to quickly rotate and scale the image to focus on key features, and 3) interact with other users in a shared virtual space enabling real-time collaborative exploration and discussion. We found that immersive VR technology allows the user to rapidly understand cellular architecture and protein or molecule distribution. We note that it is impossible to understand the value of immersive visualization without experiencing it first hand, so we encourage readers to get access to a VR system, download this software, and evaluate it for yourself. The ConfocalVR software is available for download at http://www.confocalvr.com, and is free for nonprofits. Copyright © 2018. Published by Elsevier Ltd.

  6. MRMC analysis of agreement studies

    NASA Astrophysics Data System (ADS)

    Gallas, Brandon D.; Anam, Amrita; Chen, Weijie; Wunderlich, Adam; Zhang, Zhiwei

    2016-03-01

    The purpose of this work is to present and evaluate methods based on U-statistics to compare intra- or inter-reader agreement across different imaging modalities. We apply these methods to multi-reader multi-case (MRMC) studies. We measure reader-averaged agreement and estimate its variance accounting for the variability from readers and cases (an MRMC analysis). In our application, pathologists (readers) evaluate patient tissue mounted on glass slides (cases) in two ways. They evaluate the slides on a microscope (reference modality) and they evaluate digital scans of the slides on a computer display (new modality). In the current work, we consider concordance as the agreement measure, but many of the concepts outlined here apply to other agreement measures. Concordance is the probability that two readers rank two cases in the same order. Concordance can be estimated with a U-statistic and thus it has some nice properties: it is unbiased, asymptotically normal, and its variance is given by an explicit formula. Another property of a U-statistic is that it is symmetric in its inputs; it doesn't matter which reader is listed first or which case is listed first, the result is the same. Using this property and a few tricks while building the U-statistic kernel for concordance, we get a mathematically tractable problem and efficient software. Simulations show that our variance and covariance estimates are unbiased.

  7. Microterminal/Microfiche System for Computer-Based Instruction: Hardware and Software Development.

    DTIC Science & Technology

    1980-10-01

    Circuit Description and Schematic of Adaptor Module 57 Appendix C Circuit Description The schematics for circuitry used in the microfiche viewer and the...composed of four major components and associated interfaces. The major components are (a) mirroterminal. (Is) microfiche reader. (0) memory module , and (d...sensing of the position of the platen containing the microfiche so that frame locations can be verified by the microterminal software. The memory module is

  8. Automated image quality evaluation of T2 -weighted liver MRI utilizing deep learning architecture.

    PubMed

    Esses, Steven J; Lu, Xiaoguang; Zhao, Tiejun; Shanbhogue, Krishna; Dane, Bari; Bruno, Mary; Chandarana, Hersh

    2018-03-01

    To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T 2 -weighted (T 2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T 2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T 2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T 2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T 2 WI of the liver. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728. © 2017 International Society for Magnetic Resonance in Medicine.

  9. A Novel Marking Reader for Progressive Addition Lenses Based on Gabor Holography.

    PubMed

    Perucho, Beatriz; Picazo-Bueno, José Angel; Micó, Vicente

    2016-05-01

    Progressive addition lenses (PALs) are marked with permanent engraved marks (PEMs) at standardized locations. Permanent engraved marks are very useful through the manufacturing and mounting processes, act as locator marks to re-ink the removable marks, and contain useful information about the PAL. However, PEMs are often faint and weak, obscured by scratches, partially occluded, and difficult to recognize on tinted lenses or with antireflection or scratch-resistant coatings. The aim of this article is to present a new generation of portable marking reader based on an extremely simplified concept for visualization and identification of PEMs in PALs. Permanent engraved marks on different PALs are visualized using classical Gabor holography as underlying principle. Gabor holography allows phase sample visualization with adjustable magnification and can be implemented in either classical or digital versions. Here, visual Gabor holography is used to provide a magnified defocused image of the PEMs onto a translucent visualization screen where the PEM is clearly identified. Different types of PALs (conventional, personalized, old and scratched, sunglasses, etc.) have been tested to visualize PEMs with the proposed marking reader. The PEMs are visible in every case, and variable magnification factor can be achieved simply moving up and down the PAL in the instrument. In addition, a second illumination wavelength is also tested, showing the applicability of this novel marking reader for different illuminations. A new concept of marking reader ophthalmic instrument has been presented and validated in the laboratory. The configuration involves only a commercial-grade laser diode and a visualization screen for PEM identification. The instrument is portable, economic, and easy to use, and it can be used for identifying patient's current PAL model and for marking removable PALs again or finding test points regardless of the age of the PAL, its scratches, tints, or coatings.

  10. Prostate and Colon Cancer Screening Messages in Popular Magazines

    PubMed Central

    Katz, Mira L; Sheridan, Stacey; Pignone, Michael; Lewis, Carmen; Battle, Jamila; Gollop, Claudia; O'Malley, Michael

    2004-01-01

    OBJECTIVES To 1) compare the number of articles published about prostate, colon, and breast cancer in popular magazines during the past 2 decades, and 2) evaluate the content of in-depth prostate and colon cancer screening articles identified from 1996 to 2001. DESIGN We used a searchable database to identify the number of prostate, colon, and breast cancer articles published in three magazines with the highest circulation from six categories. In addition, we performed a systematic review on the in-depth (≥2 pages) articles on prostate and colon cancer screening that appeared from 1996 through 2001. RESULTS Although the number of magazine articles on prostate and colon cancer published in the 1990s increased compared to the 1980s, the number of articles is approximately one third of breast cancer articles. There were 36 in-depth articles from 1996 to 2001 in which prostate or colon cancer screening were mentioned. Over 90% of the articles recommended screening. However, of those articles, only 76% (25/33; 95% confidence interval [CI], 58% to 89%) cited screening guidelines. The benefits of screening were mentioned in 89% (32/36; 95% CI, 74% to 97%) but the harms were only found in 58% (21/36; 95% CI, 41% to 75%). Only 28% (10/36; 95% CI, 14% to 45%) of the articles provided all the necessary information needed for the reader to make an informed decision. CONCLUSIONS In-depth articles about prostate and colon cancer in popular magazines do not appear as frequently as articles about breast cancer. The available articles on prostate and colon cancer screening often do not provide the information necessary for the reader to make an informed decision about screening. PMID:15242469

  11. Design and Development of a Clinical Risk Management Tool Using Radio Frequency Identification (RFID)

    PubMed Central

    Pourasghar, Faramarz; Tabrizi, Jafar Sadegh; Yarifard, Khadijeh

    2016-01-01

    Background: Patient safety is one of the most important elements of quality of healthcare. It means preventing any harm to the patients during medical care process. Objective: This paper introduces a cost-effective tool in which the Radio Frequency Identification (RFID) technology is used to identify medical errors in hospital. Methods: The proposed clinical error management system (CEMS) is consisted of a reader device, a transfer/receiver device, a database and managing software. The reader device works using radio waves and is wireless. The reader sends and receives data to/from the database via the transfer/receiver device which is connected to the computer via USB port. The database contains data about patients’ medication orders. Results: The CEMS has the ability to identify the clinical errors before they occur and then warns the care-giver with voice and visual messages to prevent the error. This device reduces the errors and thus improves the patient safety. Conclusion: A new tool including software and hardware was developed in this study. Application of this tool in clinical settings can help the nurses prevent medical errors. It can also be a useful tool for clinical risk management. Using this device can improve the patient safety to a considerable extent and thus improve the quality of healthcare. PMID:27147802

  12. Design and Development of a Clinical Risk Management Tool Using Radio Frequency Identification (RFID).

    PubMed

    Pourasghar, Faramarz; Tabrizi, Jafar Sadegh; Yarifard, Khadijeh

    2016-04-01

    Patient safety is one of the most important elements of quality of healthcare. It means preventing any harm to the patients during medical care process. This paper introduces a cost-effective tool in which the Radio Frequency Identification (RFID) technology is used to identify medical errors in hospital. The proposed clinical error management system (CEMS) is consisted of a reader device, a transfer/receiver device, a database and managing software. The reader device works using radio waves and is wireless. The reader sends and receives data to/from the database via the transfer/receiver device which is connected to the computer via USB port. The database contains data about patients' medication orders. The CEMS has the ability to identify the clinical errors before they occur and then warns the care-giver with voice and visual messages to prevent the error. This device reduces the errors and thus improves the patient safety. A new tool including software and hardware was developed in this study. Application of this tool in clinical settings can help the nurses prevent medical errors. It can also be a useful tool for clinical risk management. Using this device can improve the patient safety to a considerable extent and thus improve the quality of healthcare.

  13. Evaluating the Interpretations and Use of Curriculum-Based Measurement in Reading and Word Lists for Universal Screening in First and Second Grade

    ERIC Educational Resources Information Center

    January, Stacy-Ann A.; Ardoin, Scott P.; Christ, Theodore J.; Eckert, Tanya L.; White, Mary Jane

    2016-01-01

    Universal screening in elementary schools often includes administering curriculum-based measurement in reading (CBM-R); but in first grade, nonsense word fluency (NWF) and, to a lesser extent, word identification fluency (WIF) are used because of concerns that CBM-R is too difficult for emerging readers. This study used Kane's argument-based…

  14. Sight-Word Practice in a Flash!

    ERIC Educational Resources Information Center

    Erwin, Robin W., Jr.

    2016-01-01

    For learners who need sight-word practice, including young students and struggling readers, digital flash cards may promote automatic word recognition when used as a supplemental activity to regular reading instruction. A novel use of common presentation software efficiently supports this practice strategy.

  15. The Role and Design of Screen Images in Software Documentation.

    ERIC Educational Resources Information Center

    van der Meij, Hans

    2000-01-01

    Discussion of learning a new computer software program focuses on how to support the joint handling of a manual, input devices, and screen display. Describes a study that examined three design styles for manuals that included screen images to reduce split-attention problems and discusses theory versus practice and cognitive load theory.…

  16. An operations manual for the digital data system

    NASA Technical Reports Server (NTRS)

    Jones, Michael G.

    1988-01-01

    The Digital Data System (DDS) was designed to incorporate the analog-to-digital conversion process into the initial data acquisition stage and to store the data in a digital format. This conversion is done as part of the acquisition process. Consequently, the data are ready to be analyzed as soon as the test is completed. This capability permits the researcher to alter test parameters during the course of the experiment based on the information acquired in a prior portion of the test. The DDS is currently able to simultaneously acquire up to 10 channels of data. The purpose of this document is fourfold: (1) to describe the capabilities of the hardware in sufficient detail to allow the reader to determine whether the DDS is the optimum system for a particular experiment; (2) to present some of the more significant software developed to provide analyses within a short time of the completion of data acquisition; (3) to provide the reader with sample runs of major software routines to demonstrate their convenience and simple usage; and (4) a portion of the document is used to describe software which uses an FFT-box to provide a means of comparison against which the DDS can be checked.

  17. Multireader multicase reader studies with binary agreement data: simulation, analysis, validation, and sizing.

    PubMed

    Chen, Weijie; Wunderlich, Adam; Petrick, Nicholas; Gallas, Brandon D

    2014-10-01

    We treat multireader multicase (MRMC) reader studies for which a reader's diagnostic assessment is converted to binary agreement (1: agree with the truth state, 0: disagree with the truth state). We present a mathematical model for simulating binary MRMC data with a desired correlation structure across readers, cases, and two modalities, assuming the expected probability of agreement is equal for the two modalities ([Formula: see text]). This model can be used to validate the coverage probabilities of 95% confidence intervals (of [Formula: see text], [Formula: see text], or [Formula: see text] when [Formula: see text]), validate the type I error of a superiority hypothesis test, and size a noninferiority hypothesis test (which assumes [Formula: see text]). To illustrate the utility of our simulation model, we adapt the Obuchowski-Rockette-Hillis (ORH) method for the analysis of MRMC binary agreement data. Moreover, we use our simulation model to validate the ORH method for binary data and to illustrate sizing in a noninferiority setting. Our software package is publicly available on the Google code project hosting site for use in simulation, analysis, validation, and sizing of MRMC reader studies with binary agreement data.

  18. Modification of infant hypothyroidism and phenylketonuria screening program using electronic tools.

    PubMed

    Taheri, Behjat; Haddadpoor, Asefeh; Mirkhalafzadeh, Mahmood; Mazroei, Fariba; Aghdak, Pezhman; Nasri, Mehran; Bahrami, Gholamreza

    2017-01-01

    Congenital hypothyroidism and phenylketonuria (PKU) are the most common cause for preventable mental retardation in infants worldwide. Timely diagnosis and treatment of these disorders can have lasting effects on the mental development of newborns. However, there are several problems at different stages of screening programs that along with imposing heavy costs can reduce the precision of the screening, increasing the chance of undiagnosed cases which in turn can have damaging consequences for the society. Therefore, given these problems and the importance of information systems in facilitating the management and improving the quality of health care the aim of this study was to improve the screening process of hypothyroidism and PKU in infants with the help of electronic resources. The current study is a qualitative, action research designed to improve the quality of screening, services, performance, implementation effectiveness, and management of hypothyroidism and PKU screening program in Isfahan province. To this end, web-based software was designed. Programming was carried out using Delphi.net software and used SQL Server 2008 for database management. Given the weaknesses, problems, and limitations of hypothyroidism and PKU screening program, and the importance of these diseases in a national scale, this study resulted in design of hypothyroidism and PKU screening software for infants in Isfahan province. The inputs and outputs of the software were designed in three levels including Health Care Centers in charge of the screening program, provincial reference lab, and health and treatment network of Isfahan province. Immediate registration of sample data at the time and location of sampling, providing the provincial reference Laboratory and Health Centers of different eparchies with the ability to instantly observe, monitor, and follow-up on the samples at any moment, online verification of samples by reference lab, creating a daily schedule for reference lab, and receiving of the results from analysis equipment; and entering the results into the database without the need for user input are among the features of this software. The implementation of hypothyroidism screening software led to an increase in the quality and efficiency of the screening program; minimized the risk of human error in the process and solved many of the previous limitations of the screening program which were the main goals for implementation of this software. The implementation of this software also resulted in improvement in precision and quality of services provided for these two diseases and better accuracy and precision for data inputs by providing the possibility of entering the sample data at the place and time of sampling which then resulted in the possibility of management based on precise data and also helped develop a comprehensive database and improved the satisfaction of service recipients.

  19. CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results

    PubMed Central

    Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290

  20. Expert system verification and validation study: ES V/V Workshop

    NASA Technical Reports Server (NTRS)

    French, Scott; Hamilton, David

    1992-01-01

    The primary purpose of this document is to build a foundation for applying principles of verification and validation (V&V) of expert systems. To achieve this, some V&V as applied to conventionally implemented software is required. Part one will discuss the background of V&V from the perspective of (1) what is V&V of software and (2) V&V's role in developing software. Part one will also overview some common analysis techniques that are applied when performing V&V of software. All of these materials will be presented based on the assumption that the reader has little or no background in V&V or in developing procedural software. The primary purpose of part two is to explain the major techniques that have been developed for V&V of expert systems.

  1. Simulation Insights Using "R"

    ERIC Educational Resources Information Center

    Kostadinov, Boyan

    2013-01-01

    This article attempts to introduce the reader to computational thinking and solving problems involving randomness. The main technique being employed is the Monte Carlo method, using the freely available software "R for Statistical Computing." The author illustrates the computer simulation approach by focusing on several problems of…

  2. Research and design on system of asset management based on RFID

    NASA Astrophysics Data System (ADS)

    Guan, Peng; Du, HuaiChang; Jing, Hua; Zhang, MengYue; Zhang, Meng; Xu, GuiXian

    2011-10-01

    By analyzing the problems in the current assets management, this thesis proposing RFID technology will be applied to asset management in order to improve the management level of automation and information. This paper designed the equipment identification based on 433MHz RFID tag and reader which was deeply studied on the basis of RFID tag and card reader circuits, and this paper also illustrates the system of asset management. The RS232 converts Ethernet is a innovative technology to transfer data to PC monitor software, and implement system of asset management based on WEB techniques (PHP and MySQL).

  3. Quick and Easy: Use Screen Capture Software to Train and Communicate

    ERIC Educational Resources Information Center

    Schuster, Ellen

    2011-01-01

    Screen capture (screen cast) software can be used to develop short videos for training purposes. Developing videos is quick and easy. This article describes how these videos are used as tools to reinforce face-to-face and interactive TV curriculum training in a nutrition education program. Advantages of developing these videos are shared.…

  4. E-Books in Higher Education: Nearing the End of the Era of Hype?

    ERIC Educational Resources Information Center

    Nelson, Mark R.

    2008-01-01

    This article looks at some of the hype and the reality of e-books in higher education. An e-book is an electronic book that can be read digitally on a computer screen, a special e-book reader, a personal digital assistant (PDA), or even a mobile phone. In other words, e-books are consumed on a screen rather than on paper. However, underlying this…

  5. The Ins and Outs of Access Control.

    ERIC Educational Resources Information Center

    Longworth, David

    1999-01-01

    Presents basic considerations when school districts plan to acquire an access-control system for their education facilities. Topics cover cards and readers, controllers, software, automation, card technology, expandability, price, specification of needs beyond the canned specifications already supplied, and proper usage training to cardholders.…

  6. Consuming Web Services: A Yahoo! Newsfeed Reader

    ERIC Educational Resources Information Center

    Dadashzadeh, Mohammad

    2010-01-01

    Service Oriented Architecture (SOA) shows demonstrable signs of simplifying software integration. It provides the necessary framework for building applications that can be integrated and can reduce the cost of integration significantly. Organizations are beginning to architect new integration solutions following the SOA approach. As such,…

  7. UK Naval Dockyards Asbestosis Study: radiological methods in the surveillance of workers exposed to asbestos

    PubMed Central

    Sheers, G.; Rossiter, C. E.; Gilson, J. C.; Mackenzie, F. A. F.

    1978-01-01

    ABSTRACT In a survey of the effects of exposure to asbestos in the UK Naval Dockyards, small- and large-film chest radiographs of 674 men have been examined. These films have been read under survey conditions by two readers using a simple screening classification, and also in a controlled trial by five readers using the full ILO U/C classification. Comparison between the reading methods showed a deficiency, independent of the size of film, of at least 30% in the detection of asbestos-related radiographic abnormalities when the screening classification was used. For adequate diagnostic sensitivity the ILO U/C classification appears to be essential. There was a deficiency of 43% in significant abnormalities observed by a majority of readers in the small films when directly compared with large film readings. This deficiency could be reduced to 7% by using readings of the small films at any level of abnormality by any of the five readers. When the ILO U/C readings were related to the clinical diagnoses, the only abnormality missed was a small pleural plaque. Films with previously agreed coding were inserted at intervals during the reading trial and helped to maintain the consistency of reading. Right oblique views were taken for 1884 men, in addition to the full-sized postero-anterior view, but the contribution provided by this view proved insufficient to justify its use in large surveys. The cost of a survey when small films are used as a screening method is reduced to between one-third and one-half of the cost when large films are used, assuming that the abnormality rate is not more than 5%. However, this cost advantage for small films is likely to be overtaken by the development of automatic large-film units. The radiation dose when small films are used is increased by a factor of about 20, but is within the prescribed safety level. It is concluded that at least three readers should be involved, using the full ILO U/C classification. Small films may be of particular use in a large-scale survey, in which the abnormality rate is expected to be low, and which might otherwise be too expensive. A sensitive reading method and a high standard of film quality are essential factors in the use of this technique. PMID:698132

  8. 3D movies for teaching seafloor bathymetry, plate tectonics, and ocean circulation in large undergraduate classes

    NASA Astrophysics Data System (ADS)

    Peterson, C. D.; Lisiecki, L. E.; Gebbie, G.; Hamann, B.; Kellogg, L. H.; Kreylos, O.; Kronenberger, M.; Spero, H. J.; Streletz, G. J.; Weber, C.

    2015-12-01

    Geologic problems and datasets are often 3D or 4D in nature, yet projected onto a 2D surface such as a piece of paper or a projection screen. Reducing the dimensionality of data forces the reader to "fill in" that collapsed dimension in their minds, creating a cognitive challenge for the reader, especially new learners. Scientists and students can visualize and manipulate 3D datasets using the virtual reality software developed for the immersive, real-time interactive 3D environment at the KeckCAVES at UC Davis. The 3DVisualizer software (Billen et al., 2008) can also operate on a desktop machine to produce interactive 3D maps of earthquake epicenter locations and 3D bathymetric maps of the seafloor. With 3D projections of seafloor bathymetry and ocean circulation proxy datasets in a virtual reality environment, we can create visualizations of carbon isotope (δ13C) records for academic research and to aid in demonstrating thermohaline circulation in the classroom. Additionally, 3D visualization of seafloor bathymetry allows students to see features of seafloor most people cannot observe first-hand. To enhance lessons on mid-ocean ridges and ocean basin genesis, we have created movies of seafloor bathymetry for a large-enrollment undergraduate-level class, Introduction to Oceanography. In the past four quarters, students have enjoyed watching 3D movies, and in the fall quarter (2015), we will assess how well 3D movies enhance learning. The class will be split into two groups, one who learns about the Mid-Atlantic Ridge from diagrams and lecture, and the other who learns with a supplemental 3D visualization. Both groups will be asked "what does the seafloor look like?" before and after the Mid-Atlantic Ridge lesson. Then the whole class will watch the 3D movie and respond to an additional question, "did the 3D visualization enhance your understanding of the Mid-Atlantic Ridge?" with the opportunity to further elaborate on the effectiveness of the visualization.

  9. Echelle Data Reduction Cookbook

    NASA Astrophysics Data System (ADS)

    Clayton, Martin

    This document is the first version of the Starlink Echelle Data Reduction Cookbook. It contains scripts and procedures developed by regular or heavy users of the existing software packages. These scripts are generally of two types; templates which readers may be able to modify to suit their particular needs and utilities which carry out a particular common task and can probably be used `off-the-shelf'. In the nature of this subject the recipes given are quite strongly tied to the software packages, rather than being science-data led. The major part of this document is divided into two sections dealing with scripts to be used with IRAF and with Starlink software (SUN/1).

  10. Agent-based models of cellular systems.

    PubMed

    Cannata, Nicola; Corradini, Flavio; Merelli, Emanuela; Tesei, Luca

    2013-01-01

    Software agents are particularly suitable for engineering models and simulations of cellular systems. In a very natural and intuitive manner, individual software components are therein delegated to reproduce "in silico" the behavior of individual components of alive systems at a given level of resolution. Individuals' actions and interactions among individuals allow complex collective behavior to emerge. In this chapter we first introduce the readers to software agents and multi-agent systems, reviewing the evolution of agent-based modeling of biomolecular systems in the last decade. We then describe the main tools, platforms, and methodologies available for programming societies of agents, possibly profiting also of toolkits that do not require advanced programming skills.

  11. Curling Up With a Good E-Book: Mother-Child Shared Story Reading on Screen or Paper Affects Embodied Interaction and Warmth

    PubMed Central

    Yuill, Nicola; Martin, Alex F.

    2016-01-01

    This study compared changes in cognitive, affective, and postural aspects of interaction during shared mother and child book reading on screen and on paper. Readers commonly express strong preferences for reading on paper, but several studies have shown marginal, if any, effects of text medium on cognitive outcomes such as recall. Shared reading with a parent is an engaging, affective and embodied experience across time, as well as a cognitive task, so it is important to understand how paper vs. screen affects broader aspects of these shared experiences. Mid-childhood sees a steep rise in screen use alongside a shift from shared to independent reading. We assessed how the medium of paper or screen might alter children’s shared reading experiences at this transitional age. Twenty-four 7- to 9-year-old children and their mothers were videotaped sharing a story book for 8 min in each of four conditions: mother or child as reader, paper, or tablet screen as medium. We rated videotapes for interaction warmth and child engagement by minute and analyzed dyadic postural synchrony, mothers’ commentaries and quality of children’s recall, also interviewing participants about their experiences of reading and technology. We found no differences in recall quality but interaction warmth was lower for screen than for paper, and dropped over time, notably when children read on screen. Interactions also differed between mother-led and child-led reading. We propose that mother - child posture for paper reading supported more shared activity and argue that cultural affordances of screens, together with physical differences between devices, support different behaviors that affect shared engagement, with implications for the design and use of digital technology at home and at school. We advocate studying embodied and affective aspects of shared reading to understand the overall implications of screens in children’s transition to independent reading. PMID:28018283

  12. Incidental renal tumours on low-dose CT lung cancer screening exams.

    PubMed

    Pinsky, Paul F; Dunn, Barbara; Gierada, David; Nath, P Hrudaya; Munden, Reginald; Berland, Lincoln; Kramer, Barnett S

    2017-06-01

    Introduction Renal cancer incidence has increased markedly in the United States in recent decades, largely due to incidentally detected tumours from computed tomography imaging. Here, we analyze the potential for low-dose computed tomography lung cancer screening to detect renal cancer. Methods The National Lung Screening Trial randomized subjects to three annual screens with either low-dose computed tomography or chest X-ray. Eligibility criteria included 30 + pack-years, current smoking or quit within 15 years, and age 55-74. Subjects were followed for seven years. Low-dose computed tomography screening forms collected information on lung cancer and non-lung cancer abnormalities, including abnormalities below the diaphragm. A reader study was performed on a sample of National Lung Screening Trial low-dose computed tomography images assessing presence of abnormalities below the diaphragms and abnormalities suspicious for renal cancer. Results There were 26,722 and 26,732 subjects enrolled in the low-dose computed tomography and chest X-ray arms, respectively, and there were 104 and 85 renal cancer cases diagnosed, respectively (relative risk = 1.22, 95% CI: 0.9-1.5). From 75,126 low-dose computed tomography screens, there were 46 renal cancer diagnoses within one year. Abnormalities below the diaphragm rates were 39.1% in screens with renal cancer versus 4.1% in screens without (P < 0.001). Cases with abnormalities below the diaphragms had shorter median time to diagnosis than those without (71 vs. 160 days, P = 0.004). In the reader study, 64% of renal cancer cases versus 13% of non-cases had abnormalities below the diaphragms; 55% of cases and 0.8% of non-cases had a finding suspicious for renal cancer (P < 0.001). Conclusion Low-dose computed tomography screens can potentially detect renal cancers. The benefits to harms tradeoff of incidental detection of renal tumours on low-dose computed tomography is unknown.

  13. Curling Up With a Good E-Book: Mother-Child Shared Story Reading on Screen or Paper Affects Embodied Interaction and Warmth.

    PubMed

    Yuill, Nicola; Martin, Alex F

    2016-01-01

    This study compared changes in cognitive, affective, and postural aspects of interaction during shared mother and child book reading on screen and on paper. Readers commonly express strong preferences for reading on paper, but several studies have shown marginal, if any, effects of text medium on cognitive outcomes such as recall. Shared reading with a parent is an engaging, affective and embodied experience across time, as well as a cognitive task, so it is important to understand how paper vs. screen affects broader aspects of these shared experiences. Mid-childhood sees a steep rise in screen use alongside a shift from shared to independent reading. We assessed how the medium of paper or screen might alter children's shared reading experiences at this transitional age. Twenty-four 7- to 9-year-old children and their mothers were videotaped sharing a story book for 8 min in each of four conditions: mother or child as reader, paper, or tablet screen as medium. We rated videotapes for interaction warmth and child engagement by minute and analyzed dyadic postural synchrony, mothers' commentaries and quality of children's recall, also interviewing participants about their experiences of reading and technology. We found no differences in recall quality but interaction warmth was lower for screen than for paper, and dropped over time, notably when children read on screen. Interactions also differed between mother-led and child-led reading. We propose that mother - child posture for paper reading supported more shared activity and argue that cultural affordances of screens, together with physical differences between devices, support different behaviors that affect shared engagement, with implications for the design and use of digital technology at home and at school. We advocate studying embodied and affective aspects of shared reading to understand the overall implications of screens in children's transition to independent reading.

  14. Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images.

    PubMed

    Gabriele, Alex; Marco, Valeria; Gatto, Laura; Paoletti, Giulia; Di Vito, Luca; Castriota, Fausto; Romagnoli, Enrico; Ricciardi, Andrea; Prati, Francesco

    2014-10-01

    The optical coherence tomography (OCT) evaluation of the stent anatomy requires the inspection of sequential cross section (CS). However stent coils cannot be appreciated in the conventional format as the OCT CS simply display stent struts, that are poorly representative of the stent architecture. The aim of the present study was to validate a new software (Carpet View), which unfolds the stented segment, reconstructing it as an open structure and displaying the stent meshwork. 21 patients were studied with frequency domain OCT after the deployment of different stents: seven bio-absorbable scaffolds (Dream), seven bare metal stent (Vision/Multilink8), seven drug eluting stent (Cre8). Conventional CS reconstructions were post-processed with the Carpet View software and analyzed by the same reader twice (intra-observer variability) and by two different readers (inter-observer variability). A small average difference in the number of all struts was obtained with the two methods (conventional vs carpet view reconstruction). Using the carpet view, high intra-observer and inter-observer correlations were found for the number of struts obtained in each coil. The Pearson correlation values were 0.98 (p = 0.0001) and 0.96 (p = 0.0001) respectively. The same number of coils was found when analyses were repeated by the same reader or by a different reader whilst mild differences in the count of stent junctions were reported. The Carpet View can be used to address the stent geometry with high reproducibility. This approach enables the matching of the same stent portion during serial time points and promises to improve the stent assessment.

  15. Location Based Service in Indoor Environment Using Quick Response Code Technology

    NASA Astrophysics Data System (ADS)

    Hakimpour, F.; Zare Zardiny, A.

    2014-10-01

    Today by extensive use of intelligent mobile phones, increased size of screens and enriching the mobile phones by Global Positioning System (GPS) technology use of location based services have been considered by public users more than ever.. Based on the position of users, they can receive the desired information from different LBS providers. Any LBS system generally includes five main parts: mobile devices, communication network, positioning system, service provider and data provider. By now many advances have been gained in relation to any of these parts; however the users positioning especially in indoor environments is propounded as an essential and critical issue in LBS. It is well known that GPS performs too poorly inside buildings to provide usable indoor positioning. On the other hand, current indoor positioning technologies such as using RFID or WiFi network need different hardware and software infrastructures. In this paper, we propose a new method to overcome these challenges. This method is using the Quick Response (QR) Code Technology. QR Code is a 2D encrypted barcode with a matrix structure which consists of black modules arranged in a square grid. Scanning and data retrieving process from QR Code is possible by use of different camera-enabled mobile phones only by installing the barcode reader software. This paper reviews the capabilities of QR Code technology and then discusses the advantages of using QR Code in Indoor LBS (ILBS) system in comparison to other technologies. Finally, some prospects of using QR Code are illustrated through implementation of a scenario. The most important advantages of using this new technology in ILBS are easy implementation, spending less expenses, quick data retrieval, possibility of printing the QR Code on different products and no need for complicated hardware and software infrastructures.

  16. A Novel RFID-Based Sensing Method for Low-Cost Bolt Loosening Monitoring.

    PubMed

    Wu, Jian; Cui, Xingmei; Xu, Yunpeng

    2016-01-28

    In coal mines, bolt loosening in the cage guide is affected by the harsh environmental factors and cage hoist vibration, leading to significant threats to work safety. It is crucial, to this effect, to successfully detect the status of multipoint bolts of guide structures. This paper proposes a system to monitor bolt status in harsh environments established based on the RFID technique. A proof-of-concept model was demonstrated consisting of a bolt gearing system, passive UHF RFID tags, a reader, and monitoring software. A tinfoil metal film is fixed on the retaining plate and an RFID tag bonded to a large gear, with the bolt to be detected fixed in the center of a smaller gear. The radio-frequency signal cannot be received by the reader if the tag is completely obscured by the tinfoil, and if the bolt is loose, the tag's antenna is exposed when the gear revolves. A radio-frequency signal that carries corresponding bolt's information is transmitted by the RFID tag to the RFID reader due to coil coupling, identifying loose bolt location and reporting them in the software. Confirmatory test results revealed that the system indeed successfully detects bolt loosening and comparative test results (based on a reed switch multipoint bolt loosening monitor system) provided valuable information regarding the strengths and weaknesses of the proposed system.

  17. A Novel RFID-Based Sensing Method for Low-Cost Bolt Loosening Monitoring

    PubMed Central

    Wu, Jian; Cui, Xingmei; Xu, Yunpeng

    2016-01-01

    In coal mines, bolt loosening in the cage guide is affected by the harsh environmental factors and cage hoist vibration, leading to significant threats to work safety. It is crucial, to this effect, to successfully detect the status of multipoint bolts of guide structures. This paper proposes a system to monitor bolt status in harsh environments established based on the RFID technique. A proof-of-concept model was demonstrated consisting of a bolt gearing system, passive UHF RFID tags, a reader, and monitoring software. A tinfoil metal film is fixed on the retaining plate and an RFID tag bonded to a large gear, with the bolt to be detected fixed in the center of a smaller gear. The radio-frequency signal cannot be received by the reader if the tag is completely obscured by the tinfoil, and if the bolt is loose, the tag’s antenna is exposed when the gear revolves. A radio-frequency signal that carries corresponding bolt’s information is transmitted by the RFID tag to the RFID reader due to coil coupling, identifying loose bolt location and reporting them in the software. Confirmatory test results revealed that the system indeed successfully detects bolt loosening and comparative test results (based on a reed switch multipoint bolt loosening monitor system) provided valuable information regarding the strengths and weaknesses of the proposed system. PMID:26828498

  18. The correlation of background parenchymal enhancement in the contralateral breast with patient and tumor characteristics of MRI-screen detected breast cancers.

    PubMed

    Vreemann, Suzan; Gubern-Mérida, Albert; Borelli, Cristina; Bult, Peter; Karssemeijer, Nico; Mann, Ritse M

    2018-01-01

    Higher background parenchymal enhancement (BPE) could be used for stratification of MRI screening programs since it might be related to a higher breast cancer risk. Therefore, the purpose of this study is to correlate BPE to patient and tumor characteristics in women with unilateral MRI-screen detected breast cancer who participated in an intermediate and high risk screening program. As BPE in the affected breast may be difficult to discern from enhancing cancer, we assumed that BPE in the contralateral breast is a representative measure for BPE in women with unilateral breast cancer. This retrospective study was approved by our local institutional board and a waiver for consent was granted. MR-examinations of women with unilateral breast cancers screen-detected on breast MRI were evaluated by two readers. BPE in the contralateral breast was rated according to BI-RADS. Univariate analyses were performed to study associations. Observer variability was computed. Analysis included 77 breast cancers in 76 patients (age: 48±9.8 years), including 62 invasive and 15 pure ductal carcinoma in-situ cases. A negative association between BPE and tumor grade (p≤0.016) and a positive association with progesterone status (p≤0.021) was found. The correlation was stronger when only considering invasive disease. Inter-reader agreement was substantial. Lower BPE in the contralateral breast in women with unilateral breast cancer might be associated to higher tumor grade and progesterone receptor negativity. Great care should be taken using BPE for stratification of patients to tailored screening programs.

  19. Experimental statistics for biological sciences.

    PubMed

    Bang, Heejung; Davidian, Marie

    2010-01-01

    In this chapter, we cover basic and fundamental principles and methods in statistics - from "What are Data and Statistics?" to "ANOVA and linear regression," which are the basis of any statistical thinking and undertaking. Readers can easily find the selected topics in most introductory statistics textbooks, but we have tried to assemble and structure them in a succinct and reader-friendly manner in a stand-alone chapter. This text has long been used in real classroom settings for both undergraduate and graduate students who do or do not major in statistical sciences. We hope that from this chapter, readers would understand the key statistical concepts and terminologies, how to design a study (experimental or observational), how to analyze the data (e.g., describe the data and/or estimate the parameter(s) and make inference), and how to interpret the results. This text would be most useful if it is used as a supplemental material, while the readers take their own statistical courses or it would serve as a great reference text associated with a manual for any statistical software as a self-teaching guide.

  20. Methodology of the determination of the uncertainties by using the biometric device the broadway 3D

    NASA Astrophysics Data System (ADS)

    Jasek, Roman; Talandova, Hana; Adamek, Milan

    2016-06-01

    The biometric identification by face is among one of the most widely used methods of biometric identification. Due to it provides a faster and more accurate identification; it was implemented into area of security 3D face reader by Broadway manufacturer was used to measure. It is equipped with the 3D camera system, which uses the method of structured light scanning and saves the template into the 3D model of face. The obtained data were evaluated by software Turnstile Enrolment Application (TEA). The measurements were used 3D face reader the Broadway 3D. First, the person was scanned and stored in the database. Thereafter person has already been compared with the stored template in the database for each method. Finally, a measure of reliability was evaluated for the Broadway 3D face reader.

  1. School and Community Screening Shows Malawi, Africa, to Have a High Prevalence of Latent Rheumatic Heart Disease.

    PubMed

    Sims Sanyahumbi, Amy; Sable, Craig A; Beaton, Andrea; Chimalizeni, Yamikani; Guffey, Danielle; Hosseinipour, Mina; Karlsten, Melissa; Kazembe, Peter N; Kennedy, Neil; Minard, Charles G; Penny, Daniel J

    2016-12-01

    Rheumatic heart disease (RHD) is the largest cardiac cause of morbidity and mortality in the world's youth. Early detection of RHD through echocardiographic screening in asymptomatic children may identify an early stage of disease, when secondary prophylaxis has the greatest chance of stopping disease progression. Latent RHD signifies echocardiographic evidence of RHD with no known history of acute rheumatic fever and no clinical symptoms. Determine the prevalence of latent RHD among children ages 5-16 in Lilongwe, Malawi. This is a cross-sectional study in which children ages 5 through 16 were screened for RHD using echocardiography. Screening was conducted in 3 schools and surrounding communities in the Lilongwe district of Malawi between February and April 2014. Children were diagnosed as having no, borderline, or definite RHD as defined by World Heart Federation criteria. The primary reader completed offline reads of all studies. A second reader reviewed all of the studies diagnosed as RHD, plus a selection of normal studies. A third reader served as tiebreaker for discordant diagnoses. The distribution of results was compared between gender, location, and age categories using Fisher's exact test. The prevalence of latent RHD was 3.4% (95% CI = 2.45, 4.31), with 0.7% definite RHD and 2.7% borderline RHD. There was no significant differences in prevalence between gender (P = .44), site (P = .6), urban vs. peri-urban (P = .75), or age (P = .79). Of those with definite RHD, all were diagnosed because of pathologic mitral regurgitation (MR) and 2 morphologic features of the mitral valve. Of those with borderline RHD, most met the criteria by having pathological MR (92.3%). Malawi has a high rate of latent RHD, which is consistent with other results from sub-Saharan Africa. This study strongly supports the need for a RHD prevention and control program in Malawi. © 2016 Wiley Periodicals, Inc.

  2. Virtual Screening with AutoDock: Theory and Practice

    PubMed Central

    Cosconati, Sandro; Forli, Stefano; Perryman, Alex L.; Harris, Rodney; Goodsell, David S.; Olson, Arthur J.

    2011-01-01

    Importance to the field Virtual screening is a computer-based technique for identifying promising compounds to bind to a target molecule of known structure. Given the rapidly increasing number of protein and nucleic acid structures, virtual screening continues to grow as an effective method for the discovery of new inhibitors and drug molecules. Areas covered in this review We describe virtual screening methods that are available in the AutoDock suite of programs, and several of our successes in using AutoDock virtual screening in pharmaceutical lead discovery. What the reader will gain A general overview of the challenges of virtual screening is presented, along with the tools available in the AutoDock suite of programs for addressing these challenges. Take home message Virtual screening is an effective tool for the discovery of compounds for use as leads in drug discovery, and the free, open source program AutoDock is an effective tool for virtual screening. PMID:21532931

  3. Optical Encoding Technology for Viral Screening Panels Final Report CRADA No TC02132.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenhoff, R.; Haushalter, R.

    This was a collaborative effort between Lawrence Livermore National Security, LLC, Lawrence Livermore National Laboratory (LLNL) and Parallel Synthesis Technologies, Inc. (PSTI), to develop Optical Encoding Technology for Viral Screening Panels. The goal for this effort was to prepare a portable bead reader system that would enable the development of viral and bacterial screening panels which could be used for the detection of any desired set of bacteria or viruses in any location. The main objective was to determine if the combination of a bead-based, PCR suspension array technology, formulated from Parallume encoded beads and PSTI’s multiplex assay reader systemmore » (MARS), could provide advantages in terms of the number of simultaneously measured samples, portability, ruggedness, ease of use, accuracy, precision or cost as compared to the Luminexbased system developed at LLNL. The project underwent several no cost extensions however the overall goal of demonstrating the utility of this new system was achieved. As a result of the project a significant change to the type of bead PSTI used for the suspension system was implemented allowing better performance than the commercial Luminex system.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Sennett, Charlene A.; Giger, Maryellen L.

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patientsmore » (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.« less

  5. Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Sennett, Charlene A.; Giger, Maryellen L.

    2014-01-15

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patientsmore » (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.« less

  6. The Microcomputer in the Library: VI. Implementation and Future Development.

    ERIC Educational Resources Information Center

    Leggate, Peter; Dyer, Hilary

    1986-01-01

    This sixth article in a series discusses planning for the installation and implementation of automated systems in the library, workstation design and location, scheduling of software implementation, security, data input, staff and reader training, job design, impact of automation on library procedures, evaluation of system performance, and future…

  7. Music Software and Young Children: Fun and Focused Instruction

    ERIC Educational Resources Information Center

    Peters, G. David

    2009-01-01

    Readers have experienced the acceleration in music technology developments in recent years. The ease with which students and teacher can access digital audio files, video clips of music performances, and online instructional resources is impressive. Creativity "environments" were developed in a game-like format for children to experiment with…

  8. Implicature, Pragmatics, and Documentation: A Comparative Study

    ERIC Educational Resources Information Center

    Wright, David

    2008-01-01

    This study investigates the link between the linguistic principles of implicature and pragmatics and software documentation. When implicatures are created in conversation or text, the listener or reader is required to fill in missing information not overtly stated. This information is usually filled in on the basis of previous knowledge or…

  9. Viewing Files | Smokefree 60+

    Cancer.gov

    In addition to standard HTML webpages, our website contains files in other formats. You may need additional software or browser plug-ins to view some of these files. The following list shows each format along with links to the corresponding freely available plug-ins or viewers. Documents  Adobe Acrobat Reader (.pdf)

  10. Quantitative digital image analysis of chromogenic assays for high throughput screening of alpha-amylase mutant libraries.

    PubMed

    Shankar, Manoharan; Priyadharshini, Ramachandran; Gunasekaran, Paramasamy

    2009-08-01

    An image analysis-based method for high throughput screening of an alpha-amylase mutant library using chromogenic assays was developed. Assays were performed in microplates and high resolution images of the assay plates were read using the Virtual Microplate Reader (VMR) script to quantify the concentration of the chromogen. This method is fast and sensitive in quantifying 0.025-0.3 mg starch/ml as well as 0.05-0.75 mg glucose/ml. It was also an effective screening method for improved alpha-amylase activity with a coefficient of variance of 18%.

  11. Improving Science Communication with Responsive Web Design

    NASA Astrophysics Data System (ADS)

    Hilverda, M.

    2013-12-01

    Effective science communication requires clarity in both content and presentation. Content is increasingly being viewed via the Web across a broad range of devices, which can vary in screen size, resolution, and pixel density. Readers access the same content from desktop computers, tablets, smartphones, and wearable computing devices. Creating separate presentation formats optimized for each device is inefficient and unrealistic as new devices continually enter the marketplace. Responsive web design is an approach that puts content first within a presentation design that responds automatically to its environment. This allows for one platform to be maintained that can be used effectively for every screen. The layout adapts to screens of all sizes ensuring easy viewing of content for readers regardless of their device. Responsive design is accomplished primarily by the use of media queries within style sheets, which allows for changes to layout properties to be defined based on media types (i.e. screen, print) and resolution. Images and other types of multimedia can also be defined to scale automatically to fit different screen dimensions, although some media types require additional effort for proper implementation. Hardware changes, such as high pixel density screens, also present new challenges for effective presentation of content. High pixel density screens contain a greater number of pixels within a screen area increasing the pixels per inch (PPI) compared to standard screens. The result is increased clarity for text and vector media types, but often decreased clarity for standard resolution raster images. Media queries and other custom solutions can assist by specifying higher resolution images for high pixel density screens. Unfortunately, increasing image resolution results in significantly more data being transferred to the device. Web traffic on mobile devices such as smartphones and tablets is on a steady growth trajectory and many mobile devices around the world use low-bandwidth connections. Communicating science effectively includes efficient delivery of the information to the reader. To meet this criteria, responsive designs should also incorporate "mobile first" elements such as serving ideal image sizes (a low resolution cell phone does not need to receive a large desktop image) and a focus on fast, readable content delivery. The technical implementation of responsive web design is constantly changing as new web standards and approaches become available. However, fundamental design principles such as grid layouts, clear typography, and proper use of white space should be an important part of content delivery within any responsive design. This presentation will discuss current responsive design approaches for improving scientific communication across multiple devices, operating systems, and bandwidth capacities. The presentation will also include example responsive designs for scientific papers and websites. Implementing a responsive design approach with a focus on content and fundamental design principles is an important step to ensuring scientific information remains clear and accessible as screens and devices continue to evolve.

  12. The influence of reading expertise in mirror-letter perception: Evidence from beginning and expert readers

    PubMed Central

    Duñabeitia, Jon Andoni; Dimitropoulou, María; Estévez, Adelina; Carreiras, Manuel

    2013-01-01

    The visual word recognition system recruits neuronal systems originally developed for object perception which are characterized by orientation insensitivity to mirror reversals. It has been proposed that during reading acquisition beginning readers have to “unlearn” this natural tolerance to mirror reversals in order to efficiently discriminate letters and words. Therefore, it is supposed that this unlearning process takes place in a gradual way and that reading expertise modulates mirror-letter discrimination. However, to date no supporting evidence for this has been obtained. We present data from an eye-movement study that investigated the degree of sensitivity to mirror-letters in a group of beginning readers and a group of expert readers. Participants had to decide which of the two strings presented on a screen corresponded to an auditorily presented word. Visual displays always included the correct target word and one distractor word. Results showed that those distractors that were the same as the target word except for the mirror lateralization of two internal letters attracted participants’ attention more than distractors created by replacement of two internal letters. Interestingly, the time course of the effects was found to be different for the two groups, with beginning readers showing a greater tolerance (decreased sensitivity) to mirror-letters than expert readers. Implications of these findings are discussed within the framework of preceding evidence showing how reading expertise modulates letter identification. PMID:24273596

  13. Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips

    NASA Astrophysics Data System (ADS)

    Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang

    2016-02-01

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.

  14. Analyzing Dental Implant Sites From Cone Beam Computed Tomography Scans on a Tablet Computer: A Comparative Study Between iPad and 3 Display Systems.

    PubMed

    Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya

    2017-06-01

    The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.

  15. Screening, separation, and evaluation of xanthine oxidase inhibitors from Paeonia lactiflora using chromatography combined with a multi-mode microplate reader.

    PubMed

    Wang, Jing; Shi, Dongfang; Zheng, Meizhu; Ma, Bing; Cui, Jing; Liu, Chunming; Liu, Chengyu

    2017-11-01

    Natural products have become one of the most important resources for discovering novel xanthine oxidase inhibitors, which are commonly employed in the treatment of hyperuricemia and gout. However, to date, few reports exist regarding the use of monoterpene glycosides as xanthine oxidase inhibitors. Thus, we herein report the use of ultrafiltration coupled with liquid chromatography in the screening of monoterpene glycoside xanthine oxidase inhibitors from the extract of Paeonia lactiflora (P. lactiflora), and both high-performance counter-current chromatography and medium-pressure liquid chromatography were employed to separate the main constituents. Furthermore, the xanthine oxidase inhibitory activities and the mechanisms of inhibition of the isolated compounds were evaluated using a multi-mode microplate reader by Molecular Devices. As a result, three monoterpene glycosides were separated by combined high-performance counter-current chromatography and medium-pressure liquid chromatography in purities of 90.4, 98.0, and 86.3%, as determined by liquid chromatography. These three compounds were identified as albiflorin, paeoniflorin, and 1-O-β-ᴅ-glucopyranosyl-8-O-benzoylpaeonisuffrone by electrospray ionization tandem mass spectrometry, and albiflorin and paeoniflorin were screened as potential xanthine oxidase inhibitors by ultrafiltration with liquid chromatography. The evaluation results of xanthine oxidase inhibitory activity corresponded with the screening results, as only albiflorin and paeoniflorin exhibited xanthine oxidase inhibitory activity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development of an automated MODS plate reader to detect early growth of Mycobacterium tuberculosis.

    PubMed

    Comina, G; Mendoza, D; Velazco, A; Coronel, J; Sheen, P; Gilman, R H; Moore, D A J; Zimic, M

    2011-06-01

    In this work, an automated microscopic observation drug susceptibility (MODS) plate reader has been developed. The reader automatically handles MODS plates and after autofocussing digital images are acquired of the characteristic microscopic cording structures of Mycobacterium tuberculosis, which are the identification method utilized in the MODS technique to detect tuberculosis and multidrug resistant tuberculosis. In conventional MODS, trained technicians manually move the MODS plate on the stage of an inverted microscope while trying to locate and focus upon the characteristic microscopic cording colonies. In centres with high tuberculosis diagnostic demand, sufficient time may not be available to adequately examine all cultures. An automated reader would reduce labour time and the handling of M. tuberculosis cultures by laboratory personnel. Two hundred MODS culture images (100 from tuberculosis positive and 100 from tuberculosis negative sputum samples confirmed by a standard MODS reading using a commercial microscope) were acquired randomly using the automated MODS plate reader. A specialist analysed these digital images with the help of a personal computer and designated them as M. tuberculosis present or absent. The specialist considered four images insufficiently clear to permit a definitive reading. The readings from the 196 valid images resulted in a 100% agreement with the conventional nonautomated standard reading. The automated MODS plate reader combined with open-source MODS pattern recognition software provides a novel platform for high throughput automated tuberculosis diagnosis. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

  17. Validation of the Explorer® 2.0 test coupled to e-Reader® for the screening of antimicrobials in muscle from different animal species.

    PubMed

    Mata, Luis; Sanz, David; Razquin, Pedro

    2014-01-01

    The Explorer(®) 2.0 tube test is a microbial inhibition test for the screening of antimicrobial residues in food samples. The new e-Reader(®) device coupled to Explorer(®) 2.0 operates by incubation at a selected temperature, determination of the endpoint of the assay and interpretation to generate results. This system was validated for muscle samples according to the European Commission Decision 2002/657/EC. Sensitivity towards 25 substances from several groups of antimicrobials was investigated in a first step. Detection capabilities for six substances representing the six major antimicrobial groups were also determined in bovine muscle. The detection capabilities for amoxicillin (10 µg l(-1)), cefalexin (200 µg l(-1)), doxycyclin (100 µg l(-1)), sulfamethazine (100 µg l(-1)), tylosin (100 µg l(-1)) and neomycin (200 µg l(-1)) were in all cases at or below the maximum residue limit (MRL). Specificity and applicability of the test were demonstrated with muscle samples from four animal species (bovine, porcine, ovine and poultry) and results were found to be satisfactory. Ruggedness was evaluated on negative and spiked samples with sulfamethazine as a representative antimicrobial. Neither false-positives nor false-negatives were detected when varying the sample volume, the time of pre-incubation, the temperature of incubation and the batch of the test. These results prove that Explorer(®) 2.0 coupled to e-Reader(®) is a valuable tool for the screening of a broad range of antimicrobials in muscle. This new methodology simplifies the analysis and increases the accuracy of interpretation of the test results since the endpoint of the assay is automatically determined and results are interpreted objectively.

  18. ENCoRE: an efficient software for CRISPR screens identifies new players in extrinsic apoptosis.

    PubMed

    Trümbach, Dietrich; Pfeiffer, Susanne; Poppe, Manuel; Scherb, Hagen; Doll, Sebastian; Wurst, Wolfgang; Schick, Joel A

    2017-11-25

    As CRISPR/Cas9 mediated screens with pooled guide libraries in somatic cells become increasingly established, an unmet need for rapid and accurate companion informatics tools has emerged. We have developed a lightweight and efficient software to easily manipulate large raw next generation sequencing datasets derived from such screens into informative relational context with graphical support. The advantages of the software entitled ENCoRE (Easy NGS-to-Gene CRISPR REsults) include a simple graphical workflow, platform independence, local and fast multithreaded processing, data pre-processing and gene mapping with custom library import. We demonstrate the capabilities of ENCoRE to interrogate results from a pooled CRISPR cellular viability screen following Tumor Necrosis Factor-alpha challenge. The results not only identified stereotypical players in extrinsic apoptotic signaling but two as yet uncharacterized members of the extrinsic apoptotic cascade, Smg7 and Ces2a. We further validated and characterized cell lines containing mutations in these genes against a panel of cell death stimuli and involvement in p53 signaling. In summary, this software enables bench scientists with sensitive data or without access to informatic cores to rapidly interpret results from large scale experiments resulting from pooled CRISPR/Cas9 library screens.

  19. Audit feedback on reading performance of screening mammograms: An international comparison.

    PubMed

    Hofvind, S; Bennett, R L; Brisson, J; Lee, W; Pelletier, E; Flugelman, A; Geller, B

    2016-09-01

    Providing feedback to mammography radiologists and facilities may improve interpretive performance. We conducted a web-based survey to investigate how and why such feedback is undertaken and used in mammographic screening programmes. The survey was sent to representatives in 30 International Cancer Screening Network member countries where mammographic screening is offered. Seventeen programmes in 14 countries responded to the survey. Audit feedback was aimed at readers in 14 programmes, and facilities in 12 programmes. Monitoring quality assurance was the most common purpose of audit feedback. Screening volume, recall rate, and rate of screen-detected cancers were typically reported performance measures. Audit reports were commonly provided annually, but more frequently when target guidelines were not reached. The purpose, target audience, performance measures included, form and frequency of the audit feedback varied amongst mammographic screening programmes. These variations may provide a basis for those developing and improving such programmes. © The Author(s) 2016.

  20. Screen Miniatures as Icons for Backward Navigation in Content-Based Software.

    ERIC Educational Resources Information Center

    Boling, Elizabeth; Ma, Guoping; Tao, Chia-Wen; Askun, Cengiz; Green, Tim; Frick, Theodore; Schaumburg, Heike

    Users of content-based software programs, including hypertexts and instructional multimedia, rely on the navigation functions provided by the designers of those program. Typical navigation schemes use abstract symbols (arrows) to label basic navigational functions like moving forward or backward through screen displays. In a previous study, the…

  1. Ethical, financial, and legal considerations to implementing emergency department HIV screening: a report from the 2007 conference of the National Emergency Department HIV Testing Consortium.

    PubMed

    Waxman, Michael J; Popick, Rachel S; Merchant, Roland C; Rothman, Richard E; Shahan, Judy B; Almond, Gregory

    2011-07-01

    We seek to identify and analyze, from a group of participants experienced with HIV screening, the perceived challenges and solutions to the ethical, financial, and legal considerations of emergency department (ED)-based HIV screening. We performed a qualitative analysis of the focus group discussions from the ethical, financial, and legal considerations portion of the inaugural National Emergency Department HIV Testing Consortium conference. Four groups composed of 20 to 25 consortium participants engaged in semistructured, facilitated focus group discussions. The focus group discussions were audiotaped and transcribed. A primary reader identified major themes and subthemes and representative quotes from the transcripts and summarized the discussions. Secondary and tertiary readers reviewed the themes, subthemes, and summaries for accuracy. The focus group discussions centered on the following themes. Ethical considerations included appropriateness of HIV screening in the ED and ethics of key elements of the 2006 Centers for Disease Control and Prevention HIV testing recommendations. Financial considerations included models of payment and support, role of health care insurance, financial ethics and downstream financial burdens, and advocacy approaches. Legal considerations included the adequacy of obtaining consent, partner notification, disclosure of HIV results, difficulties in addressing special populations, failure of not performing universal screening, failure to notify a person of being tested, failure to notify someone of their test results, liability of inaccurate tests, and failure to link to care. This qualitative analysis provides a broadly useful foundation to the ethical, financial, and legal considerations of implementing HIV screening programs in EDs throughout the United States. Copyright © 2011. Published by Mosby, Inc.

  2. An Investigation of the Effects of Reader Characteristics on Reading Comprehension Of a General Chemistry Text

    NASA Astrophysics Data System (ADS)

    Neiles, Kelly Y.

    There is great concern in the scientific community that students in the United States, when compared with other countries, are falling behind in their scientific achievement. Increasing students' reading comprehension of scientific text may be one of the components involved in students' science achievement. To investigate students' reading comprehension this quantitative study examined the effects of different reader characteristics, namely, students' logical reasoning ability, factual chemistry knowledge, working memory capacity, and schema of the chemistry concepts, on reading comprehension of a chemistry text. Students' reading comprehension was measured through their ability to encode the text, access the meanings of words (lexical access), make bridging and elaborative inferences, and integrate the text with their existing schemas to make a lasting mental representation of the text (situational model). Students completed a series of tasks that measured the reader characteristic and reading comprehension variables. Some of the variables were measured using new technologies and software to investigate different cognitive processes. These technologies and software included eye tracking to investigate students' lexical accessing and a Pathfinder program to investigate students' schema of the chemistry concepts. The results from this study were analyzed using canonical correlation and regression analysis. The canonical correlation analysis allows for the ten variables described previously to be included in one multivariate analysis. Results indicate that the relationship between the reader characteristic variables and the reading comprehension variables is significant. The resulting canonical function accounts for a greater amount of variance in students' responses then any individual variable. Regression analysis was used to further investigate which reader characteristic variables accounted for the differences in students' responses for each reading comprehension variable. The results from this regression analysis indicated that the two schema measures (measured by the Pathfinder program) accounted for the greatest amount of variance in four of the reading comprehension variables (encoding the text, bridging and elaborative inferences, and delayed recall of a general summary). This research suggest that providing students with background information on chemistry concepts prior to having them read the text may result in better understanding and more effective incorporation of the chemistry concepts into their schema.

  3. Directional Radio-Frequency Identification Tag Reader

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J.; Taylor, John D.; Henderson, John J.

    2004-01-01

    A directional radio-frequency identification (RFID) tag reader has been designed to facilitate finding a specific object among many objects in a crowded room. The device could be an adjunct to an electronic inventory system that tracks RFID-tagged objects as they move through reader-equipped doorways. Whereas commercial RFID-tag readers do not measure directions to tagged objects, the device is equipped with a phased-array antenna and a received signal-strength indicator (RSSI) circuit for measuring direction. At the beginning of operation, it is set to address only the RFID tag of interest. It then continuously transmits a signal to interrogate that tag while varying the radiation pattern of the antenna. It identifies the direction to the tag as the radiation pattern direction of peak strength of the signal returned by the tag. An approximate distance to the tag is calculated from the peak signal strength. The direction and distance can be displayed on a screen. A prototype containing a Yagi antenna was found to be capable of detecting a 915.5-MHz tag at a distance of approximately equal to 15 ft (approximately equal to 4.6 m).

  4. The effect of prevalence of disease on performance of residents and fellows during training for interpreting DBT in a test-train-test observer study

    NASA Astrophysics Data System (ADS)

    Hakim, Christiane M.; Chang Sen, Lauren; Degnan, Andrew; Delic, Joseph; Pai, Sarah; Sagreiya, Hersh; Sparrow, Mark; Thomas, Ernestine; Yannes, Michael; Gur, David

    2017-03-01

    There are no data on the effect of disease prevalence during training for interpreting digital breast tomosynthesis (DBT) based screening examinations on the performance of residents and fellows. We assessed the performance of six residents (four after one breast imaging rotation and two after two rotations) and two fellows in breast imaging when interpreting DBT screening examinations in a multi-case, mode balanced, test- train-test retrospective reader study (127 training and 160 testing cases). Half were trained with feedback of verified truth after reviewing each case with low prevalence of disease (13/127) and half with high prevalence (52/128). The pre- and post- training dataset was the same. Performance measures were compared (sensitivity, specificity and AUC). Readers trained with the low prevalence set decreased the overall recall rate of non-cancer cases (FPF from 0.21 to 0.13, <0.001), and of cases with known malignancies (TPF from 0.70 to 0.61, p=0.004, due primarily to one clearly outlier reader). Readers trained with the high prevalence increased the overall recall rate (albeit, not statistically significant) of non-cancer cases (FPF from 0.16 to 0.18, p=0.07), and a borderline significant increase of cancer cases (TPF from 0.61 to 0.66, p=0.04). Fellows post six months of specialty training in each group had no significant changes in sensitivity, specificity, or AUC after training (smallest p>0.07). Both residents with two rotations experience had significant changes in sensitivity and specificity (highest p<0.028), but not in AUC. Early training with low disease prevalence of "what not to recall" should be included during training.

  5. Smartphone, tablet computer and e-reader use by people with vision impairment.

    PubMed

    Crossland, Michael D; Silva, Rui S; Macedo, Antonio F

    2014-09-01

    Consumer electronic devices such as smartphones, tablet computers, and e-book readers have become far more widely used in recent years. Many of these devices contain accessibility features such as large print and speech. Anecdotal experience suggests people with vision impairment frequently make use of these systems. Here we survey people with self-identified vision impairment to determine their use of this equipment. An internet-based survey was advertised to people with vision impairment by word of mouth, social media, and online. Respondents were asked demographic information, what devices they owned, what they used these devices for, and what accessibility features they used. One hundred and thirty-two complete responses were received. Twenty-six percent of the sample reported that they had no vision and the remainder reported they had low vision. One hundred and seven people (81%) reported using a smartphone. Those with no vision were as likely to use a smartphone or tablet as those with low vision. Speech was found useful by 59% of smartphone users. Fifty-one percent of smartphone owners used the camera and screen as a magnifier. Forty-eight percent of the sample used a tablet computer, and 17% used an e-book reader. The most frequently cited reason for not using these devices included cost and lack of interest. Smartphones, tablet computers, and e-book readers can be used by people with vision impairment. Speech is used by people with low vision as well as those with no vision. Many of our (self-selected) group used their smartphone camera and screen as a magnifier, and others used the camera flash as a spotlight. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  6. High-throughput measurements of the optical redox ratio using a commercial microplate reader.

    PubMed

    Cannon, Taylor M; Shah, Amy T; Walsh, Alex J; Skala, Melissa C

    2015-01-01

    There is a need for accurate, high-throughput, functional measures to gauge the efficacy of potential drugs in living cells. As an early marker of drug response in cells, cellular metabolism provides an attractive platform for high-throughput drug testing. Optical techniques can noninvasively monitor NADH and FAD, two autofluorescent metabolic coenzymes. The autofluorescent redox ratio, defined as the autofluorescence intensity of NADH divided by that of FAD, quantifies relative rates of cellular glycolysis and oxidative phosphorylation. However, current microscopy methods for redox ratio quantification are time-intensive and low-throughput, limiting their practicality in drug screening. Alternatively, high-throughput commercial microplate readers quickly measure fluorescence intensities for hundreds of wells. This study found that a commercial microplate reader can differentiate the receptor status of breast cancer cell lines (p < 0.05) based on redox ratio measurements without extrinsic contrast agents. Furthermore, microplate reader redox ratio measurements resolve response (p < 0.05) and lack of response (p > 0.05) in cell lines that are responsive and nonresponsive, respectively, to the breast cancer drug trastuzumab. These studies indicate that the microplate readers can be used to measure the redox ratio in a high-throughput manner and are sensitive enough to detect differences in cellular metabolism that are consistent with microscopy results.

  7. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    NASA Astrophysics Data System (ADS)

    Duan, G.; Zhao, X.; Seren, H. R.; Chen, C.; Zhang, X.

    2015-12-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen.

  8. Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): analysis of interchangeability.

    PubMed

    Lou, Junyang; Obuchowski, Nancy A; Krishnaswamy, Amar; Popovic, Zoran; Flamm, Scott D; Kapadia, Samir R; Svensson, Lars G; Bolen, Michael A; Desai, Milind Y; Halliburton, Sandra S; Tuzcu, E Murat; Schoenhagen, Paul

    2015-01-01

    Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P < .001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  9. HDF Update

    NASA Technical Reports Server (NTRS)

    Pourmal, Elena

    2016-01-01

    The HDF Group maintains and evolves HDF software used by NASA ESDIS program to manage remote sense data. In this talk we will discuss new features of HDF (Virtual Datasets, Single writerMultiple reader access, Community supported HDF5 compression filters) that address storage and IO performance requirements of the applications that work with the ESDIS data products.

  10. How to Get from Cupertino to Boca Raton.

    ERIC Educational Resources Information Center

    Troxel, Duane K.; Chiavacci, Jim

    1985-01-01

    Describes seven methods to transfer data from Apple computer disks to IBM computer disks and vice versa: print out data and retype; use a commercial software package, optical-character reader, homemade cable, or modem to pass or transfer data directly; pay commercial data-transfer service; or store files on mainframe and download. (MBR)

  11. CrossTalk: The Journal of Defense Software Engineering. Volume 24, Number 3, May/June 2011

    DTIC Science & Technology

    2011-05-01

    performance to match peak capacity. Selection. Supportive devices (e.g. prosthesis , text readers) Motives Assessment of people’s motives to work...iden- tified limitation. An example might be to assign a team member with an innate ability to communicate with people and get them to feel comfortable

  12. Network Simulation Training Instructor's Guide and Student Handouts. Series #B01038.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This training material provides the reader with information on the installation of and instruction in the use of the on-line Novell Netware V2.15 training software, and consists of an Instructor's Guide and Student Handouts. The instructor's guide includes the following sections: system requirements; installation; starting the tutorial; completing…

  13. Fiction and Non-Fiction Reading and Comprehension in Preferred Books

    ERIC Educational Resources Information Center

    Topping, Keith J.

    2015-01-01

    Are the books preferred and most enjoyed by children harder than other books they read? Are non-fiction books read and understood at the same level of difficulty as fiction books? The Accelerated Reader software offers computerized comprehension quizzes of real books individually chosen by children, giving children (and teachers, librarians, and…

  14. Stories about Struggling Readers and Technology

    ERIC Educational Resources Information Center

    Anderson, Rebecca; Balajthy, Ernest

    2009-01-01

    Educators have moved on from older models of technology-based education that focused on the attributes and basic uses of the hardware and software available to them. Now they are finding the necessary creative and innovative ways to harness technology's power for school and community educational improvement. In this column, the authors tell four…

  15. A Pipeline for 3D Digital Optical Phenotyping Plant Root System Architecture

    NASA Astrophysics Data System (ADS)

    Davis, T. W.; Shaw, N. M.; Schneider, D. J.; Shaff, J. E.; Larson, B. G.; Craft, E. J.; Liu, Z.; Kochian, L. V.; Piñeros, M. A.

    2017-12-01

    This work presents a new pipeline for digital optical phenotyping the root system architecture of agricultural crops. The pipeline begins with a 3D root-system imaging apparatus for hydroponically grown crop lines of interest. The apparatus acts as a self-containing dark room, which includes an imaging tank, motorized rotating bearing and digital camera. The pipeline continues with the Plant Root Imaging and Data Acquisition (PRIDA) software, which is responsible for image capturing and storage. Once root images have been captured, image post-processing is performed using the Plant Root Imaging Analysis (PRIA) command-line tool, which extracts root pixels from color images. Following the pre-processing binarization of digital root images, 3D trait characterization is performed using the next-generation RootReader3D software. RootReader3D measures global root system architecture traits, such as total root system volume and length, total number of roots, and maximum rooting depth and width. While designed to work together, the four stages of the phenotyping pipeline are modular and stand-alone, which provides flexibility and adaptability for various research endeavors.

  16. Mining collections of compounds with Screening Assistant 2

    PubMed Central

    2012-01-01

    Background High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. Results We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Conclusions Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/. PMID:23327565

  17. Mining collections of compounds with Screening Assistant 2.

    PubMed

    Guilloux, Vincent Le; Arrault, Alban; Colliandre, Lionel; Bourg, Stéphane; Vayer, Philippe; Morin-Allory, Luc

    2012-08-31

    High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/.

  18. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen dye.

    PubMed

    Moreno, Luis A; Cox, Kendra L

    2010-11-05

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows for optimal utilization of the microplate. Additionally, the software allows importing micro plate sample configurations created in Excel and saved in comma separated values, or "csv" format. Microplate measuring configurations can be saved and recalled by the software for convenience and increased productivity. Data results can be output to a standard report, to Excel, or to an optional Report Generator Program.

  19. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen Dye

    PubMed Central

    Moreno, Luis A.; Cox, Kendra L.

    2010-01-01

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows for optimal utilization of the microplate. Additionally, the software allows importing micro plate sample configurations created in Excel and saved in comma separated values, or "csv" format. Microplate measuring configurations can be saved and recalled by the software for convenience and increased productivity. Data results can be output to a standard report, to Excel, or to an optional Report Generator Program. PMID:21189464

  20. Multireader multicase reader studies with binary agreement data: simulation, analysis, validation, and sizing

    PubMed Central

    Chen, Weijie; Wunderlich, Adam; Petrick, Nicholas; Gallas, Brandon D.

    2014-01-01

    Abstract. We treat multireader multicase (MRMC) reader studies for which a reader’s diagnostic assessment is converted to binary agreement (1: agree with the truth state, 0: disagree with the truth state). We present a mathematical model for simulating binary MRMC data with a desired correlation structure across readers, cases, and two modalities, assuming the expected probability of agreement is equal for the two modalities (P1=P2). This model can be used to validate the coverage probabilities of 95% confidence intervals (of P1, P2, or P1−P2 when P1−P2=0), validate the type I error of a superiority hypothesis test, and size a noninferiority hypothesis test (which assumes P1=P2). To illustrate the utility of our simulation model, we adapt the Obuchowski–Rockette–Hillis (ORH) method for the analysis of MRMC binary agreement data. Moreover, we use our simulation model to validate the ORH method for binary data and to illustrate sizing in a noninferiority setting. Our software package is publicly available on the Google code project hosting site for use in simulation, analysis, validation, and sizing of MRMC reader studies with binary agreement data. PMID:26158051

  1. Application of Plagiarism Screening Software in the Chemical Engineering Curriculum

    ERIC Educational Resources Information Center

    Cooper, Matthew E.; Bullard, Lisa G.

    2014-01-01

    Plagiarism is an area of increasing concern for written ChE assignments, such as laboratory and design reports, due to ease of access to text and other materials via the internet. This study examines the application of plagiarism screening software to four courses in a university chemical engineering curriculum. The effectiveness of plagiarism…

  2. Designing and Implementing an OVERFLOW Reader for ParaView and Comparing Performance Between Central Processing Units and Graphical Processing Units

    NASA Technical Reports Server (NTRS)

    Chawner, David M.; Gomez, Ray J.

    2010-01-01

    In the Applied Aerosciences and CFD branch at Johnson Space Center, computational simulations are run that face many challenges. Two of which are the ability to customize software for specialized needs and the need to run simulations as fast as possible. There are many different tools that are used for running these simulations and each one has its own pros and cons. Once these simulations are run, there needs to be software capable of visualizing the results in an appealing manner. Some of this software is called open source, meaning that anyone can edit the source code to make modifications and distribute it to all other users in a future release. This is very useful, especially in this branch where many different tools are being used. File readers can be written to load any file format into a program, to ease the bridging from one tool to another. Programming such a reader requires knowledge of the file format that is being read as well as the equations necessary to obtain the derived values after loading. When running these CFD simulations, extremely large files are being loaded and having values being calculated. These simulations usually take a few hours to complete, even on the fastest machines. Graphics processing units (GPUs) are usually used to load the graphics for computers; however, in recent years, GPUs are being used for more generic applications because of the speed of these processors. Applications run on GPUs have been known to run up to forty times faster than they would on normal central processing units (CPUs). If these CFD programs are extended to run on GPUs, the amount of time they would require to complete would be much less. This would allow more simulations to be run in the same amount of time and possibly perform more complex computations.

  3. How to Act When Research Misconduct Is Not Detected by Software but Revealed by the Author of the Plagiarized Article.

    PubMed

    Baydik, Olga D; Gasparyan, Armen Yuri

    2016-10-01

    The detection of plagiarism in scholarly articles is a complex process. It requires not just quantitative analysis with the similarity recording by anti-plagiarism software but also assessment of the readers' opinion, pointing to the theft of ideas, methodologies, and graphics. In this article we describe a blatant case of plagiarism by Chinese authors, who copied a Russian article from a non-indexed and not widely visible Russian journal, and published their own report in English in an open-access journal indexed by Scopus and Web of Science and archived in PubMed Central. The details of copying in the translated English article were presented by the Russian author to the chief editor of the index journal, consultants from Scopus, anti-plagiarism experts, and the administrator of the Committee on Publication Ethics (COPE). The correspondents from Scopus and COPE pointed to the decisive role of the editors' of the English journal who may consider further actions if plagiarism is confirmed. After all, the chief editor of the English journal retracted the article on grounds of plagiarism and published a retraction note, although no details of the complexity of the case were reported. The case points to the need for combining anti-plagiarism efforts and actively seeking opinion of non-native English-speaking authors and readers who may spot intellectual theft which is not always detected by software.

  4. Three-Dimensional Root Phenotyping with a Novel Imaging and Software Platform1[C][W][OA

    PubMed Central

    Clark, Randy T.; MacCurdy, Robert B.; Jung, Janelle K.; Shaff, Jon E.; McCouch, Susan R.; Aneshansley, Daniel J.; Kochian, Leon V.

    2011-01-01

    A novel imaging and software platform was developed for the high-throughput phenotyping of three-dimensional root traits during seedling development. To demonstrate the platform’s capacity, plants of two rice (Oryza sativa) genotypes, Azucena and IR64, were grown in a transparent gellan gum system and imaged daily for 10 d. Rotational image sequences consisting of 40 two-dimensional images were captured using an optically corrected digital imaging system. Three-dimensional root reconstructions were generated and analyzed using a custom-designed software, RootReader3D. Using the automated and interactive capabilities of RootReader3D, five rice root types were classified and 27 phenotypic root traits were measured to characterize these two genotypes. Where possible, measurements from the three-dimensional platform were validated and were highly correlated with conventional two-dimensional measurements. When comparing gellan gum-grown plants with those grown under hydroponic and sand culture, significant differences were detected in morphological root traits (P < 0.05). This highly flexible platform provides the capacity to measure root traits with a high degree of spatial and temporal resolution and will facilitate novel investigations into the development of entire root systems or selected components of root systems. In combination with the extensive genetic resources that are now available, this platform will be a powerful resource to further explore the molecular and genetic determinants of root system architecture. PMID:21454799

  5. Is there a systematic bias of apparent diffusion coefficient (ADC) measurements of the breast if measured on different workstations? An inter- and intra-reader agreement study.

    PubMed

    Clauser, Paola; Marcon, Magda; Maieron, Marta; Zuiani, Chiara; Bazzocchi, Massimo; Baltzer, Pascal A T

    2016-07-01

    To evaluate the influence of post-processing systems, intra- and inter-reader agreement on the variability of apparent diffusion coefficient (ADC) measurements in breast lesions. Forty-one patients with 41 biopsy-proven breast lesions gave their informed consent and were included in this prospective IRB-approved study. Magnetic resonance imaging (MRI) examinations were performed at 1.5 T using an EPI-DWI sequence, with b-values of 0 and 1000 s/mm(2). Two radiologists (R1, R2) reviewed the images in separate sessions and measured the ADC for lesion, using MRI-workstation (S-WS), PACS-workstation (P-WS) and a commercial DICOM viewer (O-SW). Agreement was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plots and coefficient of variation (CV). Thirty-one malignant, two high-risk and eight benign mass-like lesions were analysed. Intra-reader agreement was almost perfect (ICC-R1 = 0.974; ICC-R2 = 0.990) while inter-reader agreement was substantial (ICC from 0.615 to 0.682). Bland-Altman plots revealed a significant bias in ADC values measured between O-SW and S-WS (P = 0.025), no further systematic differences were identified. CV varied from 6.8 % to 7.9 %. Post-processing systems may have a significant, although minor, impact on ADC measurements in breast lesions. While intra-reader agreement is high, the main source of ADC variability seems to be caused by inter-reader variation. • ADC provides quantitative information on breast lesions independent from the system used. • ADC measurement using different workstations and software systems is generally reliable. • Systematic, but minor, differences may occur between different post-processing systems. • Inter-reader agreement of ADC measurements exceeded intra-reader agreement.

  6. Annotated Bibliography of Enabling Technologies for the Small Aircraft Transportation System

    NASA Technical Reports Server (NTRS)

    ONeil, Patrick D.; Tarry, Scott E.

    2002-01-01

    The following collection of research summaries are submitted as fulfillment of a request from NASA LaRC to conduct research into existing enabling technologies that support the development of the Small Aircraft Transportation System aircraft and accompanying airspace management infrastructure. Due to time and fiscal constraints, the included studies focus primarily on visual systems and architecture, flight control design, instrumentation and display, flight deck design considerations, Human-Machine Interface issues, and supporting augmentation technologies and software. This collation of summaries is divided in sections in an attempt to group similar technologies and systems. However, the reader is advised that many of these studies involve multiple technologies and systems that span across many categories. Because of this fact, studies are not easily categorized into single sections. In an attempt to help the reader more easily identify topics of interest, a SATS application description is provided for each summary. In addition, a list of acronyms provided at the front of the report to aid the reader.

  7. Fractal analysis of radiologists' visual scanning pattern in screening mammography

    NASA Astrophysics Data System (ADS)

    Alamudun, Folami T.; Yoon, Hong-Jun; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia

    2015-03-01

    Several researchers have investigated radiologists' visual scanning patterns with respect to features such as total time examining a case, time to initially hit true lesions, number of hits, etc. The purpose of this study was to examine the complexity of the radiologists' visual scanning pattern when viewing 4-view mammographic cases, as they typically do in clinical practice. Gaze data were collected from 10 readers (3 breast imaging experts and 7 radiology residents) while reviewing 100 screening mammograms (24 normal, 26 benign, 50 malignant). The radiologists' scanpaths across the 4 mammographic views were mapped to a single 2-D image plane. Then, fractal analysis was applied on the composite 4- view scanpaths. For each case, the complexity of each radiologist's scanpath was measured using fractal dimension estimated with the box counting method. The association between the fractal dimension of the radiologists' visual scanpath, case pathology, case density, and radiologist experience was evaluated using fixed effects ANOVA. ANOVA showed that the complexity of the radiologists' visual search pattern in screening mammography is dependent on case specific attributes (breast parenchyma density and case pathology) as well as on reader attributes, namely experience level. Visual scanning patterns are significantly different for benign and malignant cases than for normal cases. There is also substantial inter-observer variability which cannot be explained only by experience level.

  8. Limitations of Sensory-Motor Screening for Reading Problems in the First Grade.

    ERIC Educational Resources Information Center

    Sautter, Scott W.; Barth, Jeffrey T.

    1991-01-01

    Several assessment procedures were analyzed to determine their ability to discriminate below-average from above-average readers among 50 first graders. Results indicated that language tests were more successful in classifying reading skills than were sensory-motor and perceptual procedures. Clear cut asymmetrical hemispheric specializations,…

  9. 78 FR 33731 - Propamocarb; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-05

    ... Modeling System (PRZM/EXAMS) and Screening Concentration in Ground Water (SCI- GROW) models, the estimated... Classification System (NAICS) codes is not intended to be exhaustive, but rather provides a guide to help readers... to the notice of filing. Based upon review of the data supporting the petition, EPA has revised the...

  10. Unplanned Nutrition Education in the Schools: Sugar in Elementary Reading Texts.

    ERIC Educational Resources Information Center

    D'Onofrio, Carol N.; Singer, Rosalind

    1983-01-01

    Analysis of the foods described or pictured in over 1,600 readers, prereaders, and reading workbooks for the primary grades revealed an undue emphasis on sweets. Reading texts should be screened for unintentional messages about nutrition and sugary foods, and revised to reflect national dietary goals. (Author/PP)

  11. Multisensory Modalities for Blending and Segmenting among Early Readers

    ERIC Educational Resources Information Center

    Lee, Lay Wah

    2016-01-01

    With the advent of touch-screen interfaces on the tablet computer, multisensory elements in reading instruction have taken on a new dimension. This computer assisted language learning research aimed to determine whether specific technology features of a tablet computer can add to the functionality of multisensory instruction in early reading…

  12. Lights, Camera, Read! Arizona Reading Program Manual.

    ERIC Educational Resources Information Center

    Arizona State Dept. of Library, Archives and Public Records, Phoenix.

    This document is the manual for the Arizona Reading Program (ARP) 2003 entitled "Lights, Camera, Read!" This theme spotlights books that were made into movies, and allows readers to appreciate favorite novels and stories that have progressed to the movie screen. The manual consists of eight sections. The Introduction includes welcome…

  13. 78 FR 42072 - Consumer Advisory Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-15

    ... people with disabilities. You can listen to the audio and use a screen reader to read displayed documents...://accessibleevent.com . The Web page prompts for an Event Code which is 005202376. To learn about the features of... accommodations for people with disabilities are available upon request. The request should include a detailed...

  14. Effects of time-temperature profiles on glow curves of germanium-doped optical fibre

    NASA Astrophysics Data System (ADS)

    Lam, S. E.; Alawiah, A.; Bradley, D. A.; Mohd Noor, N.

    2017-08-01

    The Germanium (Ge) doped silica optical fibres have demonstrated the great potential to be developed as a thermoluminescent (TL) dosimeter that can be used in various applications in radiotherapy, diagnostic radiology, UV dosimetry system and food irradiation industry. Different time-temperature profile (TTP) parameters of the TL reader have been employed by many researchers in various of TL studies. Nevertheless, none of those studies adequately addressed the effects of the reader's preheat temperature and heating rate on the kinetic parameters of the TL glow curve specifically, the Ge-doped silica optical fibres. This research addresses the issue of TTP parameters with special attention to the determination of the kinetic parameters of the glow curve. The glow curve responses were explored and the kinetic parameters were analyzed by the WinGCF software, to show the effect of the preheat temperature and heating rate of the reader on Ge-doped fibre irradiated with 18 Gy of 6 MV photons radiation. The effect of TTP parameters was discussed and compared against the commercial fibre and tailored made fibre of 6 mol% Ge-doped of flat and cylindrical shape. The deconvolution of glow peaks and the kinetic parameters were obtained by the WinGCF software. This enables to fit accurately (1.5%

  15. That's Infotainment!: How to Create Your Own Screencasts

    ERIC Educational Resources Information Center

    Kroski, Ellyssa

    2009-01-01

    Screencasts are videos that record the actions that take place on the computer screen, most often including a narrative audio track, in order to demonstrate various computer-related tasks, such as how to use a software program or navigate a certain Web site. All that is needed is a standard microphone and screen recording software, which can be…

  16. Captivating Open University Students with Online Literature Search Tutorials Created Using Screen Capture Software

    ERIC Educational Resources Information Center

    Wales, Tim; Robertson, Penny

    2008-01-01

    Purpose: The aim of this paper is to share the experiences and challenges faced by the Open University Library (OUL) in using screen capture software to develop online literature search tutorials. Design/methodology/approach: A summary of information literacy support at the OUL is provided as background information to explain the decision to…

  17. A system for the real-time display of radar and video images of targets

    NASA Technical Reports Server (NTRS)

    Allen, W. W.; Burnside, W. D.

    1990-01-01

    Described here is a software and hardware system for the real-time display of radar and video images for use in a measurement range. The main purpose is to give the reader a clear idea of the software and hardware design and its functions. This system is designed around a Tektronix XD88-30 graphics workstation, used to display radar images superimposed on video images of the actual target. The system's purpose is to provide a platform for tha analysis and documentation of radar images and their associated targets in a menu-driven, user oriented environment.

  18. Reconceptualising Pedagogy: Students' Hypertext Stories with Pictures and Words.

    ERIC Educational Resources Information Center

    Russell, Glenn

    Hypertext software permits students to write non-linear stories which include pictures and words. The characteristics of these stories may be affected by student and teacher understandings of how pictures and words may be combined to produce meanings for the reader. The use of images and words in comic books and children's picture-books contribute…

  19. Experimental Evaluation of Computer Assisted Self-Assessment of Reading Comprehension: Effects on Reading Achievement and Attitude.

    ERIC Educational Resources Information Center

    Vollands, Stacy R.; And Others

    A study evaluated the effect software for self-assessment and management of reading practice had on reading achievement and motivation in two primary schools in Aberdeen, Scotland. The program utilized was The Accelerated Reader (AR) which was designed to enable curriculum based assessment of reading comprehension within the classroom. Students…

  20. A New Spin on Miscue Analysis: Using Spider Charts to Web Reading Processes

    ERIC Educational Resources Information Center

    Wohlwend, Karen E.

    2012-01-01

    This article introduces a way of seeing miscue analysis data through a "spider chart", a readily available digital graphing tool that provides an effective way to visually represent readers' complex coordination of interrelated cueing systems. A spider chart is a standard feature in recent spreadsheet software that puts a new spin on miscue…

  1. Pilot study on the use of data mining to identify cochlear implant candidates.

    PubMed

    Grisel, Jedidiah J; Schafer, Erin; Lam, Anne; Griffin, Terry

    2018-05-01

    The goal of this pilot study was to determine the clinical utility of data-mining software that screens for cochlear implant (CI) candidacy. The Auditory Implant Initiative developed a software module that screens for CI candidates via integration with a software system (Noah 4) that serves as a depository for hearing test data. To identify candidates, patient audiograms from one practice were exported into the screening module. Candidates were tracked to determine if any eventually underwent implantation. After loading 4836 audiograms from the Noah 4 system, the screening module identified 558 potential CI candidates. After reviewing the data for the potential candidates, 117 were targeted and invited to an educational event. Following the event, a total of six candidates were evaluated, and two were implanted. This objective approach to identifying candidates has the potential to address the gross underutilization of CIs by removing any bias or lack of knowledge regarding the management of severe to profound sensorineural hearing loss with CIs. The screening module was an effective tool for identifying potential CI candidates at one ENT practice. On a larger scale, the screening module has the potential to impact thousands of CI candidates worldwide.

  2. Screening CT Angiography of the Aorta, Visceral Branch Vessels, and Pelvic Arteries in Fibromuscular Dysplasia.

    PubMed

    Bolen, Michael A; Brinza, Ellen; Renapurkar, Rahul D; Kim, Esther S H; Gornik, Heather L

    2017-05-01

    This study sought to evaluate the diagnostic yield of a dedicated computed tomography angiography (CTA) protocol of the chest, abdomen, and pelvis in patients with fibromuscular dysplasia (FMD). FMD is an uncommon vascular disease that may result in stenosis, dissection, or aneurysm of nearly all arterial distributions, typically affecting medium-sized arteries. Findings from the United States Registry for Fibromuscular Dysplasia have suggested the potential need to perform screening imaging of the aorta and medium branch vessels. A total of 113 consecutive patients enrolled in our institutional FMD registry who received a tailored CTA protocol at our institution between March 2013 and June 2015 were included in this study. Arterial phase contrast-enhanced images were obtained on a dual-source scanner using high pitch and electrocardiogram trigger. Images were analyzed by 2 readers. Abnormalities including beading, aneurysm, dissection, and stenosis/occlusion were noted in aortic, renal, mesenteric, and iliac distributions. The most commonly affected vessels were the renal arteries (n = 76 [67%]), followed by the lower extremity/iliac arteries (n = 37 [32%]). Aortic abnormalities were less frequently encountered (n = 3 [3%]), including 1 case with mild dilation (4.2 cm) of the ascending aorta and 2 cases of dissection involving the descending aorta, 1 with mild dilation (4.4 cm). Incremental findings beyond those known at patient intake were commonly noted, including new areas of arterial beading (n = 55 [49%]), new aneurysms (n = 21 [19%]), and new dissections (n = 3 [3%]). Reformatted images were crucial, affecting final assessment in 56% of cases evaluated by reader 1 and 36% evaluated by reader 2. Screening chest, abdomen, and pelvis CTA in patients with FMD showed substantial and incremental diagnostic yield. Reformatted images should routinely be included in imaging analysis. Abnormalities in the aorta were not common, so screening of the thoracic aorta may not be indicated. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Analyzing longitudinal data with the linear mixed models procedure in SPSS.

    PubMed

    West, Brady T

    2009-09-01

    Many applied researchers analyzing longitudinal data share a common misconception: that specialized statistical software is necessary to fit hierarchical linear models (also known as linear mixed models [LMMs], or multilevel models) to longitudinal data sets. Although several specialized statistical software programs of high quality are available that allow researchers to fit these models to longitudinal data sets (e.g., HLM), rapid advances in general purpose statistical software packages have recently enabled analysts to fit these same models when using preferred packages that also enable other more common analyses. One of these general purpose statistical packages is SPSS, which includes a very flexible and powerful procedure for fitting LMMs to longitudinal data sets with continuous outcomes. This article aims to present readers with a practical discussion of how to analyze longitudinal data using the LMMs procedure in the SPSS statistical software package.

  4. Real-Time Monitoring of Scada Based Control System for Filling Process

    NASA Astrophysics Data System (ADS)

    Soe, Aung Kyaw; Myint, Aung Naing; Latt, Maung Maung; Theingi

    2008-10-01

    This paper is a design of real-time monitoring for filling system using Supervisory Control and Data Acquisition (SCADA). The monitoring of production process is described in real-time using Visual Basic.Net programming under Visual Studio 2005 software without SCADA software. The software integrators are programmed to get the required information for the configuration screens. Simulation of components is expressed on the computer screen using parallel port between computers and filling devices. The programs of real-time simulation for the filling process from the pure drinking water industry are provided.

  5. iPads in Breast Imaging – A Phantom Study

    PubMed Central

    Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.

    2014-01-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126

  6. Video Screen Capture Basics

    ERIC Educational Resources Information Center

    Dunbar, Laura

    2014-01-01

    This article is an introduction to video screen capture. Basic information of two software programs, QuickTime for Mac and BlueBerry Flashback Express for PC, are also discussed. Practical applications for video screen capture are given.

  7. Graph Visualization for RDF Graphs with SPARQL-EndPoints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukumar, Sreenivas R; Bond, Nathaniel

    2014-07-11

    RDF graphs are hard to visualize as triples. This software module is a web interface that connects to a SPARQL endpoint and retrieves graph data that the user can explore interactively and seamlessly. The software written in python and JavaScript has been tested to work on screens as little as the smart phones to large screens such as EVEREST.

  8. A Non-imaging High Throughput Approach to Chemical Library Screening at the Unmodified Adenosine-A3 Receptor in Living Cells.

    PubMed

    Arruda, Maria Augusta; Stoddart, Leigh A; Gherbi, Karolina; Briddon, Stephen J; Kellam, Barrie; Hill, Stephen J

    2017-01-01

    Recent advances in fluorescent ligand technology have enabled the study of G protein-coupled receptors in their native environment without the need for genetic modification such as addition of N-terminal fluorescent or bioluminescent tags. Here, we have used a non-imaging plate reader (PHERAstar FS) to monitor the binding of fluorescent ligands to the human adenosine-A 3 receptor (A 3 AR; CA200645 and AV039), stably expressed in CHO-K1 cells. To verify that this method was suitable for the study of other GPCRs, assays at the human adenosine-A 1 receptor, and β 1 and β 2 adrenoceptors (β 1 AR and β 2 AR; BODIPY-TMR-CGP-12177) were also carried out. Affinity values determined for the binding of the fluorescent ligands CA200645 and AV039 to A 3 AR for a range of classical adenosine receptor antagonists were consistent with A 3 AR pharmacology and correlated well ( R 2 = 0.94) with equivalent data obtained using a confocal imaging plate reader (ImageXpress Ultra). The binding of BODIPY-TMR-CGP-12177 to the β 1 AR was potently inhibited by low concentrations of the β 1 -selective antagonist CGP 20712A (pK i 9.68) but not by the β 2 -selective antagonist ICI 118551(pK i 7.40). Furthermore, in experiments conducted in CHO K1 cells expressing the β 2 AR this affinity order was reversed with ICI 118551 showing the highest affinity (pK i 8.73) and CGP20712A (pK i 5.68) the lowest affinity. To determine whether the faster data acquisition of the non-imaging plate reader (~3 min per 96-well plate) was suitable for high throughput screening (HTS), we screened the LOPAC library for inhibitors of the binding of CA200645 to the A 3 AR. From the initial 1,263 compounds evaluated, 67 hits (defined as those that inhibited the total binding of 25 nM CA200645 by ≥40%) were identified. All compounds within the library that had medium to high affinity for the A 3 AR (pK i ≥6) were successfully identified. We found three novel compounds in the library that displayed unexpected sub-micromolar affinity for the A 3 AR. These were K114 (pK i 6.43), retinoic acid p -hydroxyanilide (pK i 6.13) and SU 6556 (pK i 6.17). Molecular docking of these latter three LOPAC library members provided a plausible set of binding poses within the vicinity of the established orthosteric A 3 AR binding pocket. A plate reader based library screening using an untagged receptor is therefore possible using fluorescent ligand opening the possibility of its use in compound screening at natively expressed receptors.

  9. The 1-min Screening Test for Reading Problems in College Students: Psychometric Properties of the 1-min TIL.

    PubMed

    Fernandes, Tânia; Araújo, Susana; Sucena, Ana; Reis, Alexandra; Castro, São Luís

    2017-02-01

    Reading is a central cognitive domain, but little research has been devoted to standardized tests for adults. We, thus, examined the psychometric properties of the 1-min version of Teste de Idade de Leitura (Reading Age Test; 1-min TIL), the Portuguese version of Lobrot L3 test, in three experiments with college students: typical readers in Experiment 1A and B, dyslexic readers and chronological age controls in Experiment 2. In Experiment 1A, test-retest reliability and convergent validity were evaluated in 185 students. Reliability was >.70, and phonological decoding underpinned 1-min TIL. In Experiment 1B, internal consistency was assessed by presenting two 45-s versions of the test to 19 students, and performance in these versions was significantly associated (r = .78). In Experiment 2, construct validity, criterion validity and clinical utility of 1-min TIL were investigated. A multiple regression analysis corroborated construct validity; both phonological decoding and listening comprehension were reliable predictors of 1-min TIL scores. Logistic regression and receiver operating characteristics analyses revealed the high accuracy of this test in distinguishing dyslexic from typical readers. Therefore, the 1-min TIL, which assesses reading comprehension and potential reading difficulties in college students, has the necessary psychometric properties to become a useful screening instrument in neuropsychological assessment and research. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. [Organized breast cancer screening].

    PubMed

    Rouëssé, Jacques; Sancho-Garnier, Hélèn

    2014-02-01

    Breast screening programs are increasingly controversial, especially regarding two points: the number of breast cancer deaths they avoid, and the problem of over-diagnosis and over-treatment. The French national breast cancer screening program was extended to cover the whole country in 2004. Ten years later it is time to examine the risk/benefit ratio of this program and to discuss the need for change. Like all forms of cancer management, screening must be regularly updated, taking into account the state of the art, new evidence, and uncertainties. All screening providers should keep themselves informed of the latest findings. In the French program, women aged 50-74 with no major individual or familial risk factors for breast cancer are offered screening mammography and clinical breast examination every two years. Images considered non suspicious of malignancy by a first reader are re-examined by a second reader. The devices and procedures are subjected to quality controls. Participating radiologists (both public and private) are required to read at least 500 mammographies per year. The program's national participation rate was 52.7 % in 2012. When individual screening outside of the national program is taken into account (nearly 15 % of women), coverage appears close to the European recommendation of 65 %. Breast cancer mortality has been falling in France by 0.6 % per year for over 30 years, starting before mass screening was implemented, and by 1.5 % since 2005. This decline can be attributed in part to earlier diagnosis and better treatment, so that the specific impact of screening cannot easily be measured. Over-treatment, defined as the detection and treatment of low-malignancy tumors that would otherwise not have been detected in a person's lifetime, is a major negative effect of screening, but its frequency is not precisely known (reported to range from 1 % to 30 %). In view of these uncertainties, it would be advisable to modify the program in order to increase its efficiency, by targeting populations at a higher risk than the women currently included, and to reduce the number of mammograms done outside the program, as they are not subject to the same quality controls. Risks could be reduced by increasing the sensitivity of mammography and the specificity of the readings. Moreover, it is mandatory to inform women of both the benefits and risks of screening, in compliance with the principle of enabling patients to make a free and informed choice.

  11. Antibiogramj: A tool for analysing images from disk diffusion tests.

    PubMed

    Alonso, C A; Domínguez, C; Heras, J; Mata, E; Pascual, V; Torres, C; Zarazaga, M

    2017-05-01

    Disk diffusion testing, known as antibiogram, is widely applied in microbiology to determine the antimicrobial susceptibility of microorganisms. The measurement of the diameter of the zone of growth inhibition of microorganisms around the antimicrobial disks in the antibiogram is frequently performed manually by specialists using a ruler. This is a time-consuming and error-prone task that might be simplified using automated or semi-automated inhibition zone readers. However, most readers are usually expensive instruments with embedded software that require significant changes in laboratory design and workflow. Based on the workflow employed by specialists to determine the antimicrobial susceptibility of microorganisms, we have designed a software tool that, from images of disk diffusion tests, semi-automatises the process. Standard computer vision techniques are employed to achieve such an automatisation. We present AntibiogramJ, a user-friendly and open-source software tool to semi-automatically determine, measure and categorise inhibition zones of images from disk diffusion tests. AntibiogramJ is implemented in Java and deals with images captured with any device that incorporates a camera, including digital cameras and mobile phones. The fully automatic procedure of AntibiogramJ for measuring inhibition zones achieves an overall agreement of 87% with an expert microbiologist; moreover, AntibiogramJ includes features to easily detect when the automatic reading is not correct and fix it manually to obtain the correct result. AntibiogramJ is a user-friendly, platform-independent, open-source, and free tool that, up to the best of our knowledge, is the most complete software tool for antibiogram analysis without requiring any investment in new equipment or changes in the laboratory. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion.

    PubMed

    Dibble, Elizabeth H; Lourenco, Ana P; Baird, Grayson L; Ward, Robert C; Maynard, A Stanley; Mainiero, Martha B

    2018-01-01

    To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 × 2 (cases and controls) × 2 breasts × 2 imaging techniques × 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p < .001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. • Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. • Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. • Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.

  13. Comparison of variability in breast density assessment by BI-RADS category according to the level of experience.

    PubMed

    Eom, Hye-Joung; Cha, Joo Hee; Kang, Ji-Won; Choi, Woo Jung; Kim, Han Jun; Go, EunChae

    2018-05-01

    Background Only few studies have assessed variability in the results obtained by the readers with different experience levels in comparison with automated volumetric breast density measurements. Purpose To examine the variations in breast density assessment according to BI-RADS categories among readers with different experience levels and to compare it with the results of automated quantitative measurements. Material and Methods Density assignment was done for 1000 screening mammograms by six readers with three different experience levels (breast-imaging experts, general radiologists, and students). Agreement level between the results obtained by the readers and the Volpara automated volumetric breast density measurements was assessed. The agreement analysis using two categories-non-dense and dense breast tissue-was also performed. Results Intra-reader agreement for experts, general radiologists, and students were almost perfect or substantial (k = 0.74-0.95). The agreement between visual assessments of the breast-imaging experts and volumetric assessments by Volpara was substantial (k = 0.77). The agreement was moderate between the experts and general radiologists (k = 0.67) and slight between the students and Volpara (k = 0.01). The agreement for the two category groups (nondense and dense) was almost perfect between the experts and Volpara (k = 0.83). The agreement was substantial between the experts and general radiologists (k = 0.78). Conclusion We observed similar high agreement levels between visual assessments of breast density performed by radiologists and the volumetric assessments. However, agreement levels were substantially lower for the untrained readers.

  14. Do You Hear What I See? Assessing Accessibility of Digital Commons and CONTENTdm

    ERIC Educational Resources Information Center

    Walker, Wendy; Keenan, Teressa

    2015-01-01

    This article discusses the accessibility of two content management systems, Berkeley Electronic Press's Digital Commons and OCLC's CONTENTdm, widely used in libraries to host institutional repository and digital collections content. Based on observations by a visually impaired student who used the JAWS screen reader to view the design and display…

  15. Comparing the Readability of Text Displays on Paper, E-Book Readers, and Small Screen Devices

    ERIC Educational Resources Information Center

    Baker, Rebecca Dawn

    2010-01-01

    Science fiction has long promised the digitalization of books. Characters in films and television routinely check their palm-sized (or smaller) electronic displays for fast-scrolling information. However, this very technology, increasingly prevalent in today's world, has not been embraced universally. While the convenience of pocket-sized…

  16. A Conceptual Framework for Emergent Digital Literacy

    ERIC Educational Resources Information Center

    Neumann, Michelle M.; Finger, Glenn; Neumann, David L.

    2017-01-01

    As we progress in the 21st century, children learn to become proficient readers and writers of both digital and non-digital texts. Knowledge, skills, and understandings of literacy emerge through sociocultural interactions with non-digital tools (e.g., paper-printed books) and digital tools (e.g., touch screen tablets). However, debate is ongoing…

  17. Multitasking operating systems for microprocessors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cramer, T.

    1981-01-01

    Microprocessors, because of their low cost, low power consumption, and small size, have caused an explosion in the number of innovative computer applications. Although there is a great deal of variation in microprocessor applications software, there is relatively little variation in the operating-system-level software from one application to the next. Nonetheless, operating system software, especially when multitasking is involved, can be very time consuming and expensive to develop. The major microprocessor manufacturers have acknowledged the need for operating systems in microprocessor applications and are now supplying real-time multitasking operating system software that is adaptable to a wide variety of usermore » systems. Use of this existing operating system software will decrease the number of redundant operating system development efforts, thus freeing programmers to work on more creative and productive problems. This paper discusses the basic terminology and concepts involved with multitasking operating systems. It is intended to provide a general understanding of the subject, so that the reader will be prepared to evaluate specific operating system software according to his or her needs. 2 references.« less

  18. Fourth Workshop on Sustainable Software for Science: Practice and Experiences (WSSSPE4)

    NASA Astrophysics Data System (ADS)

    Katz, Daniel S.; Niemeyer, Kyle E.; Gesing, Sandra; Hwang, Lorraine; Bangerth, Wolfgang; Hettrick, Simon; Idaszak, Ray; Salac, Jean; Hong, Neil Chue; Núñez-Corrales, Santiago; Allen, Alice; Geiger, R. Stuart; Miller, Jonah; Chen, Emily; Dubey, Anshu; Lago, Patricia

    This article summarizes motivations, organization, and activities of the Fourth Workshop on Sustainable Software for Science: Practice and Experiences (WSSSPE4). The WSSSPE series promotes sustainable research software by positively impacting principles and best practices, careers, learning, and credit. This article discusses the code of conduct; the mission and vision statements that were drafted at the workshop and finalized shortly after it; the keynote and idea papers, position papers, experience papers, demos, and lightning talks presented during the workshop; and a panel discussion on best practices. The main part of the article discusses the set of working groups that formed during the meeting, along with contact information for readers who may want to join a group. Finally, it discusses a survey of the workshop attendees.

  19. Acceptance testing and commissioning of Kodak Directview CR-850 digital radiography system.

    PubMed

    Bezak, E; Nelligan, R A

    2006-03-01

    This Technical Paper describes Acceptance Testing and Commissioning of the Kodak DirectView CR-850 digital radiography system installed at the Royal Adelaide Hospital. The first of its type installed in Australia, the system is a "dry" image processor, for which no chemicals are required to develop images. Rather, latent radiographic images are stored on photostimulable phosphor screens, which are scanned and displayed by a reader unit. The image can be digitally processed and enhanced before it is forwarded to a storage device, printer or workstation display, thereby alleviating the need to re-expose patients to achieve satisfactory quality images. The phosphor screens are automatically erased, ready for re-use. Results are reported of tests carried out using the optional "Total Quality Tool" quality assurance package installed with the system. This package includes analysis and reporting software which provides for simple testing and reporting of many important characteristics of the system, such as field uniformity, aspect ratio, line and pixel positions, image and system noise, exposure response, scan linearity, modulation transfer function (MTF) and image artefacts. Acceptance Tests were performed for kV and MV exposures. Resolution for MV exposures was at least 0.8 l/mm, and measured phantom dimensions were within 1.05% of expected magnification. Reproducibility between cassettes was within 1.6%. The mean pixel values on the central axis were close to linear for MV exposures from 3 to 10 MU and reached saturation level at around 20 MU for 6 MV and around 30 MV for 23 MV beams. Noise levels were below 0.2 %.

  20. Programming for physicians: A free online course.

    PubMed

    Kubben, Pieter L

    2016-01-01

    This article is an introduction for clinical readers into programming and computational thinking using the programming language Python. Exercises can be done completely online without any need for installation of software. Participants will be taught the fundamentals of programming, which are necessarily independent of the sort of application (stand-alone, web, mobile, engineering, and statistical/machine learning) that is to be developed afterward.

  1. Notice and Credits Page - NOAA's National Weather Service

    Science.gov Websites

    - Visolve is a software application (free for personal use) that transforms colors of the computer display Mac OS X 10.2 or later. (Purchase) - A 30-day free trial of eyePilot is available from eyePilot web site - http://www.colorhelper.com/ Java Java Virtual Machine - free download from java.com Adobe Reader

  2. My Virtual Reading Coach: "An Analysis of Usage and Impact," 2013-14. Technical Note. Volume 3, Number 2

    ERIC Educational Resources Information Center

    Urdegar, Steven M.

    2014-01-01

    My Virtual Reading Coach (MVRC) is an online program for students who have been identified as struggling readers. It is used as an intervention within the Response to Intervention (RtI) framework, as well as for students with disabilities. The software addresses reading sub-skills (i.e., comprehension, fluency, phonemic awareness, phonics, and…

  3. Cargo Movement Operations System (CMOS). Draft Software Programmer’s Manual

    DTIC Science & Technology

    1990-07-12

    NO ( ] COMMENT DISPOSITION: ACCEPT [ ] REJECT [ ] COMMENT STATUS: OPEN [ ] CLOSED [ ] Cmnt Page Paragraph No. No. Number Comment 1. 3-4 3.2 Change...reader in locating pertinent information. CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO ( ] COMMENT DISPOSITION: COMMENT...NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN ( ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: SPM-0006 PROGRAM

  4. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    PubMed

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  5. Optical characterization of display screens by speckle-contrast measurements

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2012-10-01

    In recent years, the flat-panel display (FPD) technology has undergone great development. Currently, FPDs are present in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surface which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider images shown in these types of displays to have more vivid colours compared with matte-screen displays. However, external light sources may cause unpleasant reflections on the glossy screens. These reflections can be reduced by a matte treatment in the front surface of FPDs. In this work, we present a method to characterize the front surface of FPDs using laser speckle patterns. We characterized three FPDs: a Samsung XL2370 LCD monitor of 23" with matte screen, a Toshiba Satellite A100 laptop of 15.4" with glossy screen, and a Papyre electronic book reader. The results show great differences in speckle contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs which have different types of front surfaces.

  6. Comparison Between Digital and Synthetic 2D Mammograms in Breast Density Interpretation.

    PubMed

    Alshafeiy, Taghreed I; Wadih, Antoine; Nicholson, Brandi T; Rochman, Carrie M; Peppard, Heather R; Patrie, James T; Harvey, Jennifer A

    2017-07-01

    The purpose of this study was to compare assessments of breast density on synthetic 2D images as compared with digital 2D mammograms. This retrospective study included consecutive women undergoing screening with digital 2D mammography and tomosynthesis during May 2015 with a negative or benign outcome. In separate reading sessions, three radiologists with 5-25 years of clinical experience and 1 year of experience with synthetic 2D mammography read digital 2D and synthetic 2D images and assigned breast density categories according to the 5th edition of BI-RADS. Inter- and intrareader agreement was assessed for each BI-RADS density assessment and combined dense and nondense categories using percent agreement and Cohen kappa coefficient for consensus and all reads. A total of 309 patients met study inclusion criteria. Agreement between consensus BI-RADS density categories assigned for digital and synthetic 2D mammography was 80.3% (95% CI, 75.4-84.5%) with κ = 0.73 (95% CI, 0.66-0.79). For combined dense and nondense categories, agreement reached 91.9% (95% CI, 88.2-94.7%). For consensus readings, similar numbers of patients were shifted between nondense and dense categories (11 and 14, respectively) with the synthetic 2D compared with digital 2D mammography. Interreader differences were apparent; assignment to dense categories was greater with digital 2D mammography for reader 1 (odds ratio [OR], 1.26; p = 0.002), the same for reader 2 (OR, 0.91; p = 0.262), and greater with synthetic 2D mammography for reader 3 (OR, 0.86; p = 0.033). Overall, synthetic 2D mammography is comparable with digital 2D mammography in assessment of breast density, though there is some variability by reader. Practices can readily adopt synthetic 2D mammography without concern that it will affect density assessment and subsequent recommendations for supplemental screening.

  7. High-throughput spectral and lifetime-based FRET screening in living cells to identify small-molecule effectors of SERCA

    PubMed Central

    Schaaf, Tory M.; Peterson, Kurt C.; Grant, Benjamin D.; Bawaskar, Prachi; Yuen, Samantha; Li, Ji; Muretta, Joseph M.; Gillispie, Gregory D.; Thomas, David D.

    2017-01-01

    A robust high-throughput screening (HTS) strategy has been developed to discover small-molecule effectors targeting the sarco/endoplasmic reticulum calcium ATPase (SERCA), based on a fluorescence microplate reader that records both the nanosecond decay waveform (lifetime mode) and the complete emission spectrum (spectral mode), with high precision and speed. This spectral unmixing plate reader (SUPR) was used to screen libraries of small molecules with a fluorescence resonance energy transfer (FRET) biosensor expressed in living cells. Ligand binding was detected by FRET associated with structural rearrangements of green (GFP, donor) and red (RFP, acceptor) fluorescent proteins fused to the cardiac-specific SERCA2a isoform. The results demonstrate accurate quantitation of FRET along with high precision of hit identification. Fluorescence lifetime analysis resolved SERCA’s distinct structural states, providing a method to classify small-molecule chemotypes on the basis of their structural effect on the target. The spectral analysis was also applied to flag interference by fluorescent compounds. FRET hits were further evaluated for functional effects on SERCA’s ATPase activity via both a coupled-enzyme assay and a FRET-based calcium sensor. Concentration-response curves indicated excellent correlation between FRET and function. These complementary spectral and lifetime FRET detection methods offer an attractive combination of precision, speed, and resolution for HTS. PMID:27899691

  8. Test set readings predict clinical performance to a limited extent: preliminary findings

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.

    2013-03-01

    Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.

  9. Implementation of a computer database testing and analysis program.

    PubMed

    Rouse, Deborah P

    2007-01-01

    The author is the coordinator of a computer software database testing and analysis program implemented in an associate degree nursing program. Computer software database programs help support the testing development and analysis process. Critical thinking is measurable and promoted with their use. The reader of this article will learn what is involved in procuring and implementing a computer database testing and analysis program in an academic nursing program. The use of the computerized database for testing and analysis will be approached as a method to promote and evaluate the nursing student's critical thinking skills and to prepare the nursing student for the National Council Licensure Examination.

  10. Computer output microfilm (FR80) systems software documentation, volume 2

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The system consists of a series of programs which convert digital data from magnetic tapes into alpha-numeric characters, graphic plots, and imagery that is recorded on the face of a cathode ray tube. A special camera photographs the face of the tube on microfilm for subsequent display on a film reader. The applicable documents which apply to this system are delineated. The functional relationship between the system software, the standard insert routines, and the applications programs is described; all the applications programs are described in detail. Instructions for locating those documents are presented along with test preparations sheets for all baseline and/or program modification acceptance tests.

  11. Development of an automated film-reading system for ballistic ranges

    NASA Technical Reports Server (NTRS)

    Yates, Leslie A.

    1992-01-01

    Software for an automated film-reading system that uses personal computers and digitized shadowgraphs is described. The software identifies pixels associated with fiducial-line and model images, and least-squares procedures are used to calculate the positions and orientations of the images. Automated position and orientation readings for sphere and cone models are compared to those obtained using a manual film reader. When facility calibration errors are removed from these readings, the accuracy of the automated readings is better than the pixel resolution, and it is equal to, or better than, the manual readings. The effects of film-reading and facility-calibration errors on calculated aerodynamic coefficients is discussed.

  12. Selecting reusable components using algebraic specifications

    NASA Technical Reports Server (NTRS)

    Eichmann, David A.

    1992-01-01

    A significant hurdle confronts the software reuser attempting to select candidate components from a software repository - discriminating between those components without resorting to inspection of the implementation(s). We outline a mixed classification/axiomatic approach to this problem based upon our lattice-based faceted classification technique and Guttag and Horning's algebraic specification techniques. This approach selects candidates by natural language-derived classification, by their interfaces, using signatures, and by their behavior, using axioms. We briefly outline our problem domain and related work. Lattice-based faceted classifications are described; the reader is referred to surveys of the extensive literature for algebraic specification techniques. Behavioral support for reuse queries is presented, followed by the conclusions.

  13. Software for universal noiseless coding

    NASA Technical Reports Server (NTRS)

    Rice, R. F.; Schlutsmeyer, A. P.

    1981-01-01

    An overview is provided of the universal noiseless coding algorithms as well as their relationship to the now available FORTRAN implementations. It is suggested that readers considering investigating the utility of these algorithms for actual applications should consult both NASA's Computer Software Management and Information Center (COSMIC) and descriptions of coding techniques provided by Rice (1979). Examples of applying these techniques have also been given by Rice (1975, 1979, 1980). Attention is given to reversible preprocessing, general implementation instructions, naming conventions, and calling arguments. A general applicability of the considered algorithms to solving practical problems is obtained because most real data sources can be simply transformed into the required form by appropriate preprocessing.

  14. All over the map: An interobserver agreement study of tumor location based on the PI-RADSv2 sector map.

    PubMed

    Greer, Matthew D; Shih, Joanna H; Barrett, Tristan; Bednarova, Sandra; Kabakus, Ismail; Law, Yan Mee; Shebel, Haytham; Merino, Maria J; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris

    2018-01-17

    Prostate imaging reporting and data system version 2 (PI-RADSv2) recommends a sector map for reporting findings of prostate cancer mulitparametric MRI (mpMRI). Anecdotally, radiologists may demonstrate inconsistent reproducibility with this map. To evaluate interobserver agreement in defining prostate tumor location on mpMRI using the PI-RADSv2 sector map. Retrospective. Thirty consecutive patients who underwent mpMRI between October, 2013 and March, 2015 and who subsequently underwent prostatectomy with whole-mount processing. 3T mpMRI with T 2 W, diffusion-weighted imaging (DWI) (apparent diffusion coefficient [ADC] and b-2000), dynamic contrast-enhanced (DCE). Six radiologists (two high, two intermediate, and two low experience) from six institutions participated. Readers were blinded to lesion location and detected up to four lesions as per PI-RADSv2 guidelines. Readers marked the long-axis of lesions, saved screen-shots of each lesion, and then marked the lesion location on the PI-RADSv2 sector map. Whole-mount prostatectomy specimens registered to the MRI served as ground truth. Index lesions were defined as the highest grade lesion or largest lesion if grades were equivalent. Agreement was calculated for the exact, overlap, and proportion of agreement. Readers detected an average of 1.9 lesions per patient (range 1.6-2.3). 96.3% (335/348) of all lesions for all readers were scored PI-RADS ≥3. Readers defined a median of 2 (range 1-18) sectors per lesion. Agreement for detecting index lesions by screen shots was 83.7% (76.1%-89.9%) vs. 71.0% (63.1-78.3%) overlap agreement on the PI-RADS sector map (P < 0.001). Exact agreement for defining sectors of detected index lesions was only 21.2% (95% confidence interval [CI]: 14.4-27.7%) and rose to 49.0% (42.4-55.3%) when overlap was considered. Agreement on defining the same level of disease (ie, apex, mid, base) was 61.4% (95% CI 50.2-71.8%). Readers are highly likely to detect the same index lesion on mpMRI, but exhibit poor reproducibility when attempting to define tumor location on the PI-RADSv2 sector map. The poor agreement of the PI-RADSv2 sector map raises concerns its utility in clinical practice. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Screening_mgmt: a Python module for managing screening data.

    PubMed

    Helfenstein, Andreas; Tammela, Päivi

    2015-02-01

    High-throughput screening is an established technique in drug discovery and, as such, has also found its way into academia. High-throughput screening generates a considerable amount of data, which is why specific software is used for its analysis and management. The commercially available software packages are often beyond the financial limits of small-scale academic laboratories and, furthermore, lack the flexibility to fulfill certain user-specific requirements. We have developed a Python module, screening_mgmt, which is a lightweight tool for flexible data retrieval, analysis, and storage for different screening assays in one central database. The module reads custom-made analysis scripts and plotting instructions, and it offers a graphical user interface to import, modify, and display the data in a uniform manner. During the test phase, we used this module for the management of 10,000 data points of various origins. It has provided a practical, user-friendly tool for sharing and exchanging information between researchers. © 2014 Society for Laboratory Automation and Screening.

  16. Optical characterization of display screens by speckle patterns

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2013-10-01

    In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.

  17. Automatic neutron dosimetry system based on fluorescent nuclear track detector technology.

    PubMed

    Akselrod, M S; Fomenko, V V; Bartz, J A; Haslett, T L

    2014-10-01

    For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Identifying Preschool Children at Risk of Later Reading Difficulties: Evaluation of Two Emergent Literacy Screening Tools

    ERIC Educational Resources Information Center

    Wilson, Shauna B.; Lonigan, Christopher J.

    2010-01-01

    Emergent literacy skills are predictive of children's early reading success, and literacy achievement in early schooling declines more rapidly for children who are below-average readers. It is therefore important for teachers to identify accurately children at risk for later reading difficulty so children can be exposed to effective emergent…

  19. ELISA test for anti-neutrophil cytoplasm antibodies detection evaluated by a computer screen photo-assisted technique.

    PubMed

    Filippini, D; Tejle, K; Lundström, I

    2005-08-15

    The computer screen photo-assisted technique (CSPT), a method for substance classification based on spectral fingerprinting, which involves just a computer screen and a web camera as measuring platform is used here for the evaluation of a prospective enzyme-linked immunosorbent assay (ELISA). A anti-neutrophil cytoplasm antibodies (ANCA-ELISA) test, typically used for diagnosing patients suffering from chronic inflammatory disorders in the skin, joints, blood vessels and other tissues is comparatively tested with a standard microplate reader and CSPT, yielding equivalent results at a fraction of the instrumental costs. The CSPT approach is discussed as a distributed measuring platform allowing decentralized measurements in routine applications, whereas keeping centralized information management due to its natural network embedded operation.

  20. Documentation of Decision-Aiding Software: Introductory Guide

    DTIC Science & Technology

    1980-02-01

    for the Manager ( New York: Holt, ’ 6 ( Simply put, the discipline assists planners and deci- sion makers in choosing between alternative courses of...con- ducting international negotiations on tanker safety; g. use by Headquarters, U.S. Marine Corps as an orga- nizing vehicle for the preparation of...literature on decision analysis. For an introductory treatment the reader should refer to Howard Raiffa, Decision Analysis (Reading, Massachusetts

  1. Applications of Text Analytics in the Intelligence Community

    DTIC Science & Technology

    2016-06-01

    TEXT ANALYTICS IN THE INTELLIGENCE COMMUNITY by Daniel M. Hall June 2016 Thesis Advisor: Johannes O. Royset Second Reader: Jon Alt THIS...Master’s thesis 4. TITLE AND SUBTITLE APPLICATIONS OF TEXT ANALYTICS IN THE INTELLIGENCE COMMUNITY 5. FUNDING NUMBERS 6. AUTHOR(S) Daniel M...DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) We evaluate Anseri, a commercial text analytics software, and its ability to assist a

  2. Programming for physicians: A free online course

    PubMed Central

    Kubben, Pieter L.

    2016-01-01

    This article is an introduction for clinical readers into programming and computational thinking using the programming language Python. Exercises can be done completely online without any need for installation of software. Participants will be taught the fundamentals of programming, which are necessarily independent of the sort of application (stand-alone, web, mobile, engineering, and statistical/machine learning) that is to be developed afterward. PMID:27127694

  3. New Developments in Breast Cancer Screening and Treatment.

    PubMed

    Tilstra, Sarah; McNeil, Melissa

    2017-01-01

    The clinical update serves as a brief review of recently published, high-impact, and potentially practice-changing journal articles summarized for our readers. In this clinical update, we selected top recent articles regarding breast health that may change the clinical practice of women's health providers. We identified articles by reviewing high-impact medical and women's health journals as well as national practice guidelines. Three of our articles are dedicated to the rapid changes in breast cancer screening. With regard to breast cancer treatment, we focused on two articles that impact who we treat with traditional aggressive regimens.

  4. CycloPs: generating virtual libraries of cyclized and constrained peptides including nonnatural amino acids.

    PubMed

    Duffy, Fergal J; Verniere, Mélanie; Devocelle, Marc; Bernard, Elise; Shields, Denis C; Chubb, Anthony J

    2011-04-25

    We introduce CycloPs, software for the generation of virtual libraries of constrained peptides including natural and nonnatural commercially available amino acids. The software is written in the cross-platform Python programming language, and features include generating virtual libraries in one-dimensional SMILES and three-dimensional SDF formats, suitable for virtual screening. The stand-alone software is capable of filtering the virtual libraries using empirical measurements, including peptide synthesizability by standard peptide synthesis techniques, stability, and the druglike properties of the peptide. The software and accompanying Web interface is designed to enable the rapid generation of large, structurally diverse, synthesizable virtual libraries of constrained peptides quickly and conveniently, for use in virtual screening experiments. The stand-alone software, and the Web interface for evaluating these empirical properties of a single peptide, are available at http://bioware.ucd.ie .

  5. Eye movement analysis of reading from computer displays, eReaders and printed books.

    PubMed

    Zambarbieri, Daniela; Carniglia, Elena

    2012-09-01

    To compare eye movements during silent reading of three eBooks and a printed book. The three different eReading tools were a desktop PC, iPad tablet and Kindle eReader. Video-oculographic technology was used for recording eye movements. In the case of reading from the computer display the recordings were made by a video camera placed below the computer screen, whereas for reading from the iPad tablet, eReader and printed book the recording system was worn by the subject and had two cameras: one for recording the movement of the eyes and the other for recording the scene in front of the subject. Data analysis provided quantitative information in terms of number of fixations, their duration, and the direction of the movement, the latter to distinguish between fixations and regressions. Mean fixation duration was different only in reading from the computer display, and was similar for the Tablet, eReader and printed book. The percentage of regressions with respect to the total amount of fixations was comparable for eReading tools and the printed book. The analysis of eye movements during reading an eBook from different eReading tools suggests that subjects' reading behaviour is similar to reading from a printed book. © 2012 The College of Optometrists.

  6. The initial data products from the EUVE software - A photon's journey through the End-to-End System

    NASA Technical Reports Server (NTRS)

    Antia, Behram

    1993-01-01

    The End-to-End System (EES) is a unique collection of software modules created for use at the Center for EUV Astrophysics. The 'pipeline' is a shell script which executes selected EES modules and creates initial data products: skymaps, data sets for individual sources (called 'pigeonholes') and catalogs of sources. This article emphasizes the data from the all-sky survey, conducted between July 22, 1992 and January 21, 1993. A description of each of the major data products will be given and, as an example of how the pipeline works, the reader will follow a photon's path through the software pipeline into a pigeonhole. These data products are the primary goal of the EUVE all-sky survey mission, and so their relative importance for the follow-up science will also be discussed.

  7. Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography.

    PubMed

    Haider, Irfanullah; Morgan, Matthew; McGow, Anna; Stein, Matthew; Rezvani, Maryam; Freer, Phoebe; Hu, Nan; Fajardo, Laurie; Winkler, Nicole

    2018-06-12

    To evaluate perceptual difference in breast density classification using synthesized mammography (SM) compared with standard or full-field digital mammography (FFDM) for screening. This institutional review board-approved, retrospective, multireader study evaluated breast density on 200 patients who underwent baseline screening mammogram during which both SM and FFDM were obtained contemporaneously from June 1, 2016, through November 30, 2016. Qualitative breast density was independently assigned by seven readers initially evaluating FFDM alone. Then, in a separate session, these same readers assigned breast density using synthetic views alone on the same 200 patients. The readers were again blinded to each other's assignment. Qualitative density assessment was based on BI-RADS fifth edition. Interreader agreement was evaluated with κ statistic using 95% confidence intervals. Testing for homogeneity in paired proportions was performed using McNemar's test with a level of significance of .05. For patients across the SM and standard 2-D data set, diagnostic testing with McNemar's test with P = 0.32 demonstrates that the minimal density transitions across FFDM and SM are not statistically significant density shifts. Taking clinical significance into account, only 8 of 200 (4%) patients had clinically significant transition (dense versus not dense). There was substantial interreader agreement with overall κ in FFDM of 0.71 (minimum 0.53, maximum 0.81) and overall SM κ average of 0.63 (minimum 0.56, maximum 0.87). Overall subjective breast density assignment by radiologists on SM is similar to density assignment on standard 2-D mammogram. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. High-throughput image analysis of tumor spheroids: a user-friendly software application to measure the size of spheroids automatically and accurately.

    PubMed

    Chen, Wenjin; Wong, Chung; Vosburgh, Evan; Levine, Arnold J; Foran, David J; Xu, Eugenia Y

    2014-07-08

    The increasing number of applications of three-dimensional (3D) tumor spheroids as an in vitro model for drug discovery requires their adaptation to large-scale screening formats in every step of a drug screen, including large-scale image analysis. Currently there is no ready-to-use and free image analysis software to meet this large-scale format. Most existing methods involve manually drawing the length and width of the imaged 3D spheroids, which is a tedious and time-consuming process. This study presents a high-throughput image analysis software application - SpheroidSizer, which measures the major and minor axial length of the imaged 3D tumor spheroids automatically and accurately; calculates the volume of each individual 3D tumor spheroid; then outputs the results in two different forms in spreadsheets for easy manipulations in the subsequent data analysis. The main advantage of this software is its powerful image analysis application that is adapted for large numbers of images. It provides high-throughput computation and quality-control workflow. The estimated time to process 1,000 images is about 15 min on a minimally configured laptop, or around 1 min on a multi-core performance workstation. The graphical user interface (GUI) is also designed for easy quality control, and users can manually override the computer results. The key method used in this software is adapted from the active contour algorithm, also known as Snakes, which is especially suitable for images with uneven illumination and noisy background that often plagues automated imaging processing in high-throughput screens. The complimentary "Manual Initialize" and "Hand Draw" tools provide the flexibility to SpheroidSizer in dealing with various types of spheroids and diverse quality images. This high-throughput image analysis software remarkably reduces labor and speeds up the analysis process. Implementing this software is beneficial for 3D tumor spheroids to become a routine in vitro model for drug screens in industry and academia.

  9. User-friendly tools on handheld devices for observer performance study

    NASA Astrophysics Data System (ADS)

    Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi

    2012-02-01

    ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.

  10. PrimerSuite: A High-Throughput Web-Based Primer Design Program for Multiplex Bisulfite PCR.

    PubMed

    Lu, Jennifer; Johnston, Andrew; Berichon, Philippe; Ru, Ke-Lin; Korbie, Darren; Trau, Matt

    2017-01-24

    The analysis of DNA methylation at CpG dinucleotides has become a major research focus due to its regulatory role in numerous biological processes, but the requisite need for assays which amplify bisulfite-converted DNA represents a major bottleneck due to the unique design constraints imposed on bisulfite-PCR primers. Moreover, a review of the literature indicated no available software solutions which accommodated both high-throughput primer design, support for multiplex amplification assays, and primer-dimer prediction. In response, the tri-modular software package PrimerSuite was developed to support bisulfite multiplex PCR applications. This software was constructed to (i) design bisulfite primers against multiple regions simultaneously (PrimerSuite), (ii) screen for primer-primer dimerizing artefacts (PrimerDimer), and (iii) support multiplex PCR assays (PrimerPlex). Moreover, a major focus in the development of this software package was the emphasis on extensive empirical validation, and over 1300 unique primer pairs have been successfully designed and screened, with over 94% of them producing amplicons of the expected size, and an average mapping efficiency of 93% when screened using bisulfite multiplex resequencing. The potential use of the software in other bisulfite-based applications such as methylation-specific PCR is under consideration for future updates. This resource is freely available for use at PrimerSuite website (www.primer-suite.com).

  11. High-content screening in microfluidic devices.

    PubMed

    Cheong, Raymond; Paliwal, Saurabh; Levchenko, Andre

    2010-08-01

    Miniaturization is the key to advancing the state of the art in high-content screening (HCS) in order to enable dramatic cost savings through reduced usage of expensive biochemical reagents and to enable large-scale screening on primary cells. Microfluidic technology offers the potential to enable HCS to be performed with an unprecedented degree of miniaturization. This perspective highlights a real-world example from the authors’ work of HCS assays implemented in a highly miniaturized microfluidic format. The advantages of this technology are discussed, including cost savings, high-throughput screening on primary cells, improved accuracy, the ability to study complex time-varying stimuli, and ease of automation, integration and scaling. The reader will understand the capabilities of anew microfluidics-based platform for HCS and the advantages it provides over conventional plate-based HCS. Microfluidics technology will drive significant advancements and broader usage and applicability of HCS in drug discovery.

  12. CT-scout based, semi-automated vertebral morphometry after digital image enhancement.

    PubMed

    Glinkowski, Wojciech M; Narloch, Jerzy

    2017-09-01

    Radiographic diagnosis of osteoporotic vertebral fracture is necessary to reduce its substantial associated morbidity. Computed tomography (CT) scout has recently been demonstrated as a reliable technique for vertebral fracture diagnosis. Software assistance may help to overcome some limitations of that diagnostics. We aimed to evaluate whether digital image enhancement improved the capacity of one of the existing software to detect fractures semi-automatically. CT scanograms of patients suffering from osteoporosis, with or without vertebral fractures were analyzed. The original set of CT scanograms were triplicated and digitally modified to improve edge detection using three different techniques: SHARPENING, UNSHARP MASKING, and CONVOLUTION. The manual morphometric analysis identified 1485 vertebrae, 200 of which were classified as fractured. Unadjusted morphometry (AUTOMATED with no digital enhancement) found 63 fractures, 33 of which were true positive (i.e., it correctly identified 52% of the fractures); SHARPENING detected 57 fractures (30 true positives, 53%); UNSHARP MASKING yielded 30 (13 true positives, 43%); and CONVOLUTION found 24 fractures (9 true positives, 38%). The intra-reader reliability for height ratios did not significantly improve with image enhancement (kappa ranged 0.22-0.41 for adjusted measurements and 0.16-0.38 for unadjusted). Similarly, the inter-reader agreement for prevalent fractures did not significantly improve with image enhancement (kappa 0.29-0.56 and -0.01 to 0.23 for adjusted and unadjusted measurements, respectively). Our results suggest that digital image enhancement does not improve software-assisted vertebral fracture detection by CT scout. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The Software Design Document: More than a User's Manual.

    ERIC Educational Resources Information Center

    Bowers, Dennis

    1989-01-01

    Discusses the value of creating design documentation for computer software so that it may serve as a model for similar design efforts. Components of the software design document are described, including program flowcharts, graphic representation of screen displays, storyboards, and evaluation procedures. An example is given using HyperCard. (three…

  14. NCLB Keeps Some Great Teaching Candidates out Forever

    ERIC Educational Resources Information Center

    Wakefield, Dara

    2007-01-01

    In this article, the author presents the story of Hope--an education student who, despite many successes, was consistently unable to pass the reading portion of a screening test (Praxis I) that is a prerequisite to student teaching in her home state of Georgia. Hope's only trouble was the fact that she was a slow reader due to attention deficit…

  15. Screen Time: Alumni Magazines Have Their Designs on Mobile Devices

    ERIC Educational Resources Information Center

    Walker, Theresa

    2011-01-01

    Alumni magazines have their designs on mobile devices. The efforts are tied together, no matter the platform, by a desire for the magazine to be where its readers are and a spirit of experimentation that is akin to what is happening with social media. None of the magazine editors went into this process with any numerical expectations for…

  16. Eye Movement Control during Reading: II. Frequency of Refixating a Word. Technical Report No. 469.

    ERIC Educational Resources Information Center

    McConkie, G. W.; And Others

    As part of a series of studies describing the oculomotor behavior of skilled readers, a study investigated whether a word refixation curve exists. Subjects, 66 college students fixating over 40,000 times, read lines of text from a computer screen and were instructed to read for meaning without regard to errors. Results of eye movement control…

  17. Converting Optically Scanned Regular or Irregular Tables to a Standardised Markup Format to Be Accessible to Vision-Impaired

    ERIC Educational Resources Information Center

    Nazemi, Azadeh; Murray, Iain; Fernaando, Chandrika; McMeekin, David A.

    2016-01-01

    Documents use tables to communicate multidimensional information clearly, summarise and present data in an easy-to-interpret way. Tabular information in scanned PDF due to its nature without further processing is not accessible for vision-impaired people who use assistive technology such as screen readers. The lack of access to table contents…

  18. Videotex in Education: Current Developments in Screen Design, Data Structure, and Access Control.

    ERIC Educational Resources Information Center

    Kerr, Stephen T.

    This four-section paper begins with a brief description of videotex and the paths its development has followed during its short lifespan. The second section examines how videotex systems should present and display information, and how such information should be internally organized so that it is maximally useful for the reader/user. The analysis,…

  19. Reading on the Computer Screen: Does Font Type Have Effects on Web Text Readability?

    ERIC Educational Resources Information Center

    Ali, Ahmad Zamzuri Mohamad; Wahid, Rahani; Samsudin, Khairulanuar; Idris, Muhammad Zaffwan

    2013-01-01

    Reading on the World Wide Web has become a daily habit nowadays. This can be seen from the perspective of changes in readers' tendency to be more interested in materials from the internet, than printed media. Taking these developments into account, it is important for web-based instructional designers to choose the appropriate font, especially for…

  20. The Combination Design of Enabling Technologies in Group Learning: New Study Support Service for Visually Impaired University Students

    ERIC Educational Resources Information Center

    Tangsri, Chatcai; Na-Takuatoong, Onjaree; Sophatsathit, Peraphon

    2013-01-01

    This article aims to show how the process of new service technology-based development improves the current study support service for visually impaired university students. Numerous studies have contributed to improving assisted aid technology such as screen readers, the development and the use of audiobooks, and technology that supports individual…

  1. Active imagination and the analysis of film.

    PubMed

    Izod, J

    2000-04-01

    The emotions aroused by the pleasure-generating mechanisms of the cinema are usually benign because they refer to a virtual world. Experiencing affects aroused by fictions can resemble being drawn into a rehearsal for a possible, imagined future that just might (but more likely never will) occur in the individual's life in the real world. Movie-goers, no less than the readers of novels, actively engage with the symbols that film makers inscribe in the screen text. In so doing, they take a measure of control over elements of the fiction. Screened fiction has thus the potential to help the individual grow in self-awareness. Shifting its focus to the work of the film critic, the paper argues that, suitably adapted to the requirements of working with a pre-recorded film or tape, Jung's concept of the active imagination helps us to model, license, limit and endorse the subjective element in textual analysis. Because the method proposed makes it possible formally to recognize that the interpretation of fiction is inevitably integrated with the analyst's personality, interpretation is always a matter of a reader bringing a text into being rather than disinterring a pre-existing object.

  2. Southern Salish Sea Habitat Map Series: Admiralty Inlet

    USGS Publications Warehouse

    Cochrane, Guy R.; Dethier, Megan N.; Hodson, Timothy O.; Kull, Kristine K.; Golden, Nadine E.; Ritchie, Andrew C.; Moegling, Crescent; Pacunski, Robert E.; Cochrane, Guy R.

    2015-01-01

    This publication includes four map sheets, explanatory text, and a descriptive pamphlet. Each map sheet is published as a portable document format (PDF) file. ESRI ArcGIS compatible geotiffs (for example, bathymetry) and shapefiles (for example video observation points) will be available for download in the data catalog associated with this publication (Cochrane, 2015). An ArcGIS Project File with the symbology used to generate the map sheets is also provided. For those who do not own the full suite of ESRI GIS and mapping software, the data can be read using ESRI ArcReader, a free viewer that is available at http://www.esri.com/software/arcgis/arcreader/index.html.

  3. Improved accuracy in ground-based facilities - Development of an automated film-reading system for ballistic ranges

    NASA Technical Reports Server (NTRS)

    Yates, Leslie A.

    1992-01-01

    Software for an automated film-reading system that uses personal computers and digitized shadowgraphs is described. The software identifies pixels associated with fiducial-line and model images, and least-squares procedures are used to calculate the positions and orientations of the images. Automated position and orientation readings for sphere and cone models are compared to those obtained using a manual film reader. When facility calibration errors are removed from these readings, the accuracy of the automated readings is better than the pixel resolution, and it is equal to, or better than, the manual readings. The effects of film-reading and facility-calibration errors on calculated aerodynamic coefficients is discussed.

  4. Coloring the FITS Universe

    NASA Astrophysics Data System (ADS)

    Levay, Z. G.

    2004-12-01

    A new, freely-available accessory for Adobe's widely-used Photoshop image editing software makes it much more convenient to produce presentable images directly from FITS data. It merges a fully-functional FITS reader with an intuitive user interface and includes fully interactive flexibility in scaling data. Techniques for producing attractive images from astronomy data using the FITS plugin will be presented, including the assembly of full-color images. These techniques have been successfully applied to producing colorful images for public outreach with data from the Hubble Space Telescope and other major observatories. Now it is much less cumbersome for students or anyone not experienced with specialized astronomical analysis software, but reasonably familiar with digital photography, to produce useful and attractive images.

  5. TRIIG - Time-lapse reproduction of images through interactive graphics. [digital processing of quality hard copy

    NASA Technical Reports Server (NTRS)

    Buckner, J. D.; Council, H. W.; Edwards, T. R.

    1974-01-01

    Description of the hardware and software implementing the system of time-lapse reproduction of images through interactive graphics (TRIIG). The system produces a quality hard copy of processed images in a fast and inexpensive manner. This capability allows for optimal development of processing software through the rapid viewing of many image frames in an interactive mode. Three critical optical devices are used to reproduce an image: an Optronics photo reader/writer, the Adage Graphics Terminal, and Polaroid Type 57 high speed film. Typical sources of digitized images are observation satellites, such as ERTS or Mariner, computer coupled electron microscopes for high-magnification studies, or computer coupled X-ray devices for medical research.

  6. Evaluating and Mitigating the Impact of Complexity in Software Models

    DTIC Science & Technology

    2015-12-01

    Internal use:* Permission to reproduce this material and to prepare derivative works from this material for internal use is granted, provided the...introduction) provides our motivation to study complexity and the essential re- search questions that we address in this effort. Some background information... provides the reader with a basis for the work and related areas explored. Section 2 (The Impact of Complexity) discusses the impact of model-based

  7. Estimating the Overdiagnosis Fraction in Cancer Screening | Division of Cancer Prevention

    Cancer.gov

    By Stuart G. Baker, 2017 Introduction This software supports the mathematical investigation into estimating the fraction of cancers detected on screening that are overdiagnosed. References Baker SG and Prorok PC. Estimating the overdiagnosis fraction in cancer screening. Requirement Mathematica Version 11 or later. |

  8. Structural basis of O-GlcNAc recognition by mammalian 14-3-3 proteins.

    PubMed

    Toleman, Clifford A; Schumacher, Maria A; Yu, Seok-Ho; Zeng, Wenjie; Cox, Nathan J; Smith, Timothy J; Soderblom, Erik J; Wands, Amberlyn M; Kohler, Jennifer J; Boyce, Michael

    2018-06-05

    O-GlcNAc is an intracellular posttranslational modification that governs myriad cell biological processes and is dysregulated in human diseases. Despite this broad pathophysiological significance, the biochemical effects of most O-GlcNAcylation events remain uncharacterized. One prevalent hypothesis is that O-GlcNAc moieties may be recognized by "reader" proteins to effect downstream signaling. However, no general O-GlcNAc readers have been identified, leaving a considerable gap in the field. To elucidate O-GlcNAc signaling mechanisms, we devised a biochemical screen for candidate O-GlcNAc reader proteins. We identified several human proteins, including 14-3-3 isoforms, that bind O-GlcNAc directly and selectively. We demonstrate that 14-3-3 proteins bind O-GlcNAc moieties in human cells, and we present the structures of 14-3-3β/α and γ bound to glycopeptides, providing biophysical insights into O-GlcNAc-mediated protein-protein interactions. Because 14-3-3 proteins also bind to phospho-serine and phospho-threonine, they may integrate information from O-GlcNAc and O-phosphate signaling pathways to regulate numerous physiological functions.

  9. RETRACTED: Effect of intranasal oxytocin administration on psychiatric symptoms: A meta-analysis of placebo-controlled studies.

    PubMed

    Hofmann, Stefan G; Fang, Angela; Brager, Daniel N

    2015-08-30

    This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This article has been retracted at the request of the authors and Editor-in-Chief of the journal. It was brought to the authors' attention that there were several significant data analytic errors linked to the data entry and the software program that was used in the published meta-analysis comparing the effect of intranasal oxytocin versus placebo administration on psychiatric symptoms. Correcting these errors changed the main result of this study. The authors greatly apologize to the journal, the reviewers, and readers for the errors in the original article, and would like to thank the readers who brought the errors to their attention. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Automatic Generation of Overlays and Offset Values Based on Visiting Vehicle Telemetry and RWS Visuals

    NASA Technical Reports Server (NTRS)

    Dunne, Matthew J.

    2011-01-01

    The development of computer software as a tool to generate visual displays has led to an overall expansion of automated computer generated images in the aerospace industry. These visual overlays are generated by combining raw data with pre-existing data on the object or objects being analyzed on the screen. The National Aeronautics and Space Administration (NASA) uses this computer software to generate on-screen overlays when a Visiting Vehicle (VV) is berthing with the International Space Station (ISS). In order for Mission Control Center personnel to be a contributing factor in the VV berthing process, computer software similar to that on the ISS must be readily available on the ground to be used for analysis. In addition, this software must perform engineering calculations and save data for further analysis.

  11. The suitability of gray-scale electronic readers for dermatology journals.

    PubMed

    Choi, Jae Eun; Kim, Dai Hyun; Seo, Soo Hong; Kye, Young Chul; Ahn, Hyo Hyun

    2014-12-01

    The rapid development of information and communication technology has replaced traditional books by electronic versions. Most print dermatology journals have been replaced with electronic journals (e-journals), which are readily used by clinicians and medical students. The objectives of this study were to determine whether e-readers are appropriate for reading dermatology journals, to conduct an attitude study of both medical personnel and students, and to find a way of improving e-book use in the field of dermatology. All articles in the Korean Journal of Dermatology published from January 2010 to December 2010 were utilized in this study. Dermatology house officers, student trainees in their fourth year of medical school, and interns at Korea University Medical Center participated in the study. After reading the articles with Kindle 2, their impressions and evaluations were recorded using a questionnaire with a 5-point Likert scale. The results demonstrated that gray-scale e-readers might not be suitable for reading dermatology journals, especially for case reports compared to the original articles. Only three of the thirty-one respondents preferred e-readers to printed papers. The most common suggestions from respondents to encourage usage of e-books in the field of dermatology were the introduction of a color display, followed by the use of a touch screen system, a cheaper price, and ready-to-print capabilities. In conclusion, our study demonstrated that current e-readers might not be suitable for reading dermatology journals. However, they may be utilized in selected situations according to the type and topic of the papers.

  12. The Suitability of Gray-Scale Electronic Readers for Dermatology Journals

    PubMed Central

    Choi, Jae Eun; Kim, Dai Hyun; Seo, Soo Hong; Kye, Young Chul

    2014-01-01

    Background The rapid development of information and communication technology has replaced traditional books by electronic versions. Most print dermatology journals have been replaced with electronic journals (e-journals), which are readily used by clinicians and medical students. Objective The objectives of this study were to determine whether e-readers are appropriate for reading dermatology journals, to conduct an attitude study of both medical personnel and students, and to find a way of improving e-book use in the field of dermatology. Methods All articles in the Korean Journal of Dermatology published from January 2010 to December 2010 were utilized in this study. Dermatology house officers, student trainees in their fourth year of medical school, and interns at Korea University Medical Center participated in the study. After reading the articles with Kindle 2, their impressions and evaluations were recorded using a questionnaire with a 5-point Likert scale. Results The results demonstrated that gray-scale e-readers might not be suitable for reading dermatology journals, especially for case reports compared to the original articles. Only three of the thirty-one respondents preferred e-readers to printed papers. The most common suggestions from respondents to encourage usage of e-books in the field of dermatology were the introduction of a color display, followed by the use of a touch screen system, a cheaper price, and ready-to-print capabilities. Conclusion In conclusion, our study demonstrated that current e-readers might not be suitable for reading dermatology journals. However, they may be utilized in selected situations according to the type and topic of the papers. PMID:25473221

  13. Three-dimensional portable document format: a simple way to present 3-dimensional data in an electronic publication.

    PubMed

    Danz, Jan C; Katsaros, Christos

    2011-08-01

    Three-dimensional (3D) models of teeth and soft and hard tissues are tessellated surfaces used for diagnosis, treatment planning, appliance fabrication, outcome evaluation, and research. In scientific publications or communications with colleagues, these 3D data are often reduced to 2-dimensional pictures or need special software for visualization. The portable document format (PDF) offers a simple way to interactively display 3D surface data without additional software other than a recent version of Adobe Reader (Adobe, San Jose, Calif). The purposes of this article were to give an example of how 3D data and their analyses can be interactively displayed in 3 dimensions in electronic publications, and to show how they can be exported from any software for diagnostic reports and communications among colleagues. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Pharmacophore screening of the protein data bank for specific binding site chemistry.

    PubMed

    Campagna-Slater, Valérie; Arrowsmith, Andrew G; Zhao, Yong; Schapira, Matthieu

    2010-03-22

    A simple computational approach was developed to screen the Protein Data Bank (PDB) for putative pockets possessing a specific binding site chemistry and geometry. The method employs two commonly used 3D screening technologies, namely identification of cavities in protein structures and pharmacophore screening of chemical libraries. For each protein structure, a pocket finding algorithm is used to extract potential binding sites containing the correct types of residues, which are then stored in a large SDF-formatted virtual library; pharmacophore filters describing the desired binding site chemistry and geometry are then applied to screen this virtual library and identify pockets matching the specified structural chemistry. As an example, this approach was used to screen all human protein structures in the PDB and identify sites having chemistry similar to that of known methyl-lysine binding domains that recognize chromatin methylation marks. The selected genes include known readers of the histone code as well as novel binding pockets that may be involved in epigenetic signaling. Putative allosteric sites were identified on the structures of TP53BP1, L3MBTL3, CHEK1, KDM4A, and CREBBP.

  15. Instruments for Reading Direct-Marked Data-Matrix Symbols

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F.; Corder, Eric L.

    2006-01-01

    Improved optoelectronic instruments (specially configured digital cameras) for reading direct-marked data-matrix symbols on the surfaces of optically reflective objects (including specularly reflective ones) are undergoing development. Data-matrix symbols are two-dimensional binary patterns that are used, like common bar codes, for automated identification of objects. The first data-matrix symbols were checkerboard-like patterns of black-and-white rectangles, typically existing in the forms of paint, ink, or detachable labels. The major advantage of direct marking (the marks are more durable than are painted or printed symbols or detachable labels) is offset by a major disadvantage (the marks generated by some marking methods do not provide sufficient contrast to be readable by optoelectronic instruments designed to read black-and-white data-matrix symbols). Heretofore, elaborate lighting, lensing, and software schemes have been tried in efforts to solve the contrast problem in direct-mark matrix- symbol readers. In comparison with prior readers based on those schemes, the readers now undergoing development are expected to be more effective while costing less. All of the prior direct-mark matrix-symbol readers are designed to be aimed perpendicularly to marked target surfaces, and they tolerate very little angular offset. However, the reader now undergoing development not only tolerates angular offset but depends on angular offset as a means of obtaining the needed contrast, as described below. The prototype reader (see Figure 1) includes an electronic camera in the form of a charge-coupled-device (CCD) image detector equipped with a telecentric lens. It also includes a source of collimated visible light and a source of collimated infrared light for illuminating a target. The visible and infrared illumination complement each other: the visible illumination is more useful for aiming the reader toward a target, while the infrared illumination is more useful for reading symbols on highly reflective surfaces. By use of beam splitters, the visible and infrared collimated lights are introduced along the optical path of the telecentric lens, so that the target is illuminated and viewed from the same direction.

  16. Approaches to virtual screening and screening library selection.

    PubMed

    Wildman, Scott A

    2013-01-01

    The ease of access to virtual screening (VS) software in recent years has resulted in a large increase in literature reports. Over 300 publications in the last year report the use of virtual screening techniques to identify new chemical matter or present the development of new virtual screening techniques. The increased use is accompanied by a corresponding increase in misuse and misinterpretation of virtual screening results. This review aims to identify many of the common difficulties associated with virtual screening and allow researchers to better assess the reliability of their virtual screening effort.

  17. The UGRID Reader - A ParaView Plugin for the Visualization of Unstructured Climate Model Data in NetCDF Format

    NASA Astrophysics Data System (ADS)

    Brisc, Felicia; Vater, Stefan; Behrens, Joern

    2016-04-01

    We present the UGRID Reader, a visualization software component that implements the UGRID Conventions into Paraview. It currently supports the reading and visualization of 2D unstructured triangular, quadrilateral and mixed triangle/quadrilateral meshes, while the data can be defined per cell or per vertex. The Climate and Forecast Metadata Conventions (CF Conventions) have been set for many years as the standard framework for climate data written in NetCDF format. While they allow storing unstructured data simply as data defined at a series of points, they do not currently address the topology of the underlying unstructured mesh. However, it is often necessary to have additional mesh topology information, i.e. is it a one dimensional network, a 2D triangular mesh or a flexible mixed triangle/quadrilateral mesh, a 2D mesh with vertical layers, or a fully unstructured 3D mesh. The UGRID Conventions proposed by the UGRID Interoperability group are attempting to fill in this void by extending the CF Conventions with topology specifications. As the UGRID Conventions are increasingly popular with an important subset of the CF community, they warrant the development of a customized tool for the visualization and exploration of UGRID-conforming data. The implementation of the UGRID Reader has been designed corresponding to the ParaView plugin architecture. This approach allowed us to tap into the powerful reading and rendering capabilities of ParaView, while the reader is easy to install. We aim at parallelism to be able to process large data sets. Furthermore, our current application of the reader is the visualization of higher order simulation output which demands for a special representation of the data within a cell.

  18. Acute non-contact anterior cruciate ligament tears are associated with relatively increased vastus medialis to semimembranosus cross-sectional area ratio: a case-control retrospective MR study.

    PubMed

    Wieschhoff, Ged G; Mandell, Jacob C; Czuczman, Gregory J; Nikac, Violeta; Shah, Nehal; Smith, Stacy E

    2017-11-01

    Hamstring muscle deficiency is increasingly recognized as a risk factor for anterior cruciate ligament (ACL) tears. The purpose of this study is to evaluate the vastus medialis to semimembranosus cross-sectional area (VM:SM CSA) ratio on magnetic resonance imaging (MRI) in patients with ACL tears compared to controls. One hundred knee MRIs of acute ACL tear patients and 100 age-, sex-, and side-matched controls were included. Mechanism of injury, contact versus non-contact, was determined for each ACL tear subject. The VM:SM CSA was measured on individual axial slices with a novel method using image-processing software. One reader measured all 200 knees and the second reader measured 50 knees at random to assess inter-reader variability. The intraclass correlation coefficient (ICC) was calculated to evaluate for correlation between readers. T-tests were performed to evaluate for differences in VM:SM CSA ratios between the ACL tear group and control group. The ICC for agreement between the two readers was 0.991 (95% confidence interval 0.984-0.995). Acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.44 vs. 1.28; p = 0.005). Non-contact acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.48 vs. 1.20; p = 0.003), whereas contact acute ACL tear patients do not (1.23 vs. 1.26; p = 0.762). Acute non-contact ACL tears are associated with increased VM:SM CSA ratios, which may imply a relative deficiency in hamstring strength. This study also demonstrates a novel method of measuring the relative CSA of muscles on MRI.

  19. Software Measurement Guidebook

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This Software Measurement Guidebook is based on the extensive experience of several organizations that have each developed and applied significant measurement programs over a period of at least 10 years. The lessons derived from those experiences reflect not only successes but also failures. By applying those lessons, an organization can minimize, or at least reduce, the time, effort, and frustration of introducing a software measurement program. The Software Measurement Guidebook is aimed at helping organizations to begin or improve a measurement program. It does not provide guidance for the extensive application of specific measures (such as how to estimate software cost or analyze software complexity) other than by providing examples to clarify points. It does contain advice for establishing and using an effective software measurement program and for understanding some of the key lessons that other organizations have learned. Some of that advice will appear counterintuitive, but it is all based on actual experience. Although all of the information presented in this guidebook is derived from specific experiences of mature measurement programs, the reader must keep in mind that the characteristics of every organization are unique. Some degree of measurement is critical for all software development and maintenance organizations, and most of the key rules captured in this report will be generally applicable. Nevertheless, each organization must strive to understand its own environment so that the measurement program can be tailored to suit its characteristics and needs.

  20. Using Docker Compose for the Simple Deployment of an Integrated Drug Target Screening Platform.

    PubMed

    List, Markus

    2017-06-10

    Docker virtualization allows for software tools to be executed in an isolated and controlled environment referred to as a container. In Docker containers, dependencies are provided exactly as intended by the developer and, consequently, they simplify the distribution of scientific software and foster reproducible research. The Docker paradigm is that each container encapsulates one particular software tool. However, to analyze complex biomedical data sets, it is often necessary to combine several software tools into elaborate workflows. To address this challenge, several Docker containers need to be instantiated and properly integrated, which complicates the software deployment process unnecessarily. Here, we demonstrate how an extension to Docker, Docker compose, can be used to mitigate these problems by providing a unified setup routine that deploys several tools in an integrated fashion. We demonstrate the power of this approach by example of a Docker compose setup for a drug target screening platform consisting of five integrated web applications and shared infrastructure, deployable in just two lines of codes.

  1. The Toxicity Estimation Software Tool (T.E.S.T.)

    EPA Science Inventory

    The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to estimate toxicological values for aquatic and mammalian species considering acute and chronic endpoints for screening purposes within TSCA and REACH programs.

  2. Breast density evaluation using spectral mammography, radiologist reader assessment and segmentation techniques: a retrospective study based on left and right breast comparison

    PubMed Central

    Molloi, Sabee; Ding, Huanjun; Feig, Stephen

    2015-01-01

    Purpose The purpose of this study was to compare the precision of mammographic breast density measurement using radiologist reader assessment, histogram threshold segmentation, fuzzy C-mean segmentation and spectral material decomposition. Materials and Methods Spectral mammography images from a total of 92 consecutive asymptomatic women (50–69 years old) who presented for annual screening mammography were retrospectively analyzed for this study. Breast density was estimated using 10 radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm and spectral material decomposition. The breast density correlation between left and right breasts was used to assess the precision of these techniques to measure breast composition relative to dual-energy material decomposition. Results In comparison to the other techniques, the results of breast density measurements using dual-energy material decomposition showed the highest correlation. The relative standard error of estimate for breast density measurements from left and right breasts using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm and dual-energy material decomposition was calculated to be 1.95, 2.87, 2.07 and 1.00, respectively. Conclusion The results indicate that the precision of dual-energy material decomposition was approximately factor of two higher than the other techniques with regard to better correlation of breast density measurements from right and left breasts. PMID:26031229

  3. Readership survey. A big welcome for Diagnostics in Africa.

    PubMed

    Chinnock, P

    1994-09-01

    Targeted to physicians, Africa Health is circulated free to 5600 readers in 23 African countries. Diagnostics in Africa (DIA) is a young publication included as a supplement of Africa Health aimed at laboratory personnel. Readers of DIA were surveyed in the first two issues to find out what they thought of the supplement, how it could be improved, and which problems they currently faced in their work. 98 questionnaires were returned from twelve African countries. 46% of respondents were qualified in laboratory science and 41% were physicians; the others were unqualified laboratory staff and other medical personnel. 73% responded that DIA was very useful and 27% useful, with 80% finding the articles of appropriate depth and complexity. Respondents would like to read about clinical chemistry, histopathology/histology, immunology, management issues, serology, and education/professional development, and would particularly enjoy material in the form of readers' letters and quizzes. Readers responded variously that they were regularly exposed to either Medicine Digest, Dialogue on Diarrhea, Postgraduate Doctor, Labmedica, Lancet, International Diabetes Digest, New England Journal of Medicine, British Medical Journal, or ARI News. Problems typically faced in their work include lack of resources, problems related to HIV testing/screening, poor access to literature, problems with professional development, and difficulty understanding the theory and practice of Western blot tests. These findings confirm assessments of the situation in Africa's medical labs which led to the launching of DIA.

  4. Assistive lesion-emphasis system: an assistive system for fundus image readers

    PubMed Central

    Rangrej, Samrudhdhi B.; Sivaswamy, Jayanthi

    2017-01-01

    Abstract. Computer-assisted diagnostic (CAD) tools are of interest as they enable efficient decision-making in clinics and the screening of diseases. The traditional approach to CAD algorithm design focuses on the automated detection of abnormalities independent of the end-user, who can be an image reader or an expert. We propose a reader-centric system design wherein a reader’s attention is drawn to abnormal regions in a least-obtrusive yet effective manner, using saliency-based emphasis of abnormalities and without altering the appearance of the background tissues. We present an assistive lesion-emphasis system (ALES) based on the above idea, for fundus image-based diabetic retinopathy diagnosis. Lesion-saliency is learnt using a convolutional neural network (CNN), inspired by the saliency model of Itti and Koch. The CNN is used to fine-tune standard low-level filters and learn high-level filters for deriving a lesion-saliency map, which is then used to perform lesion-emphasis via a spatially variant version of gamma correction. The proposed system has been evaluated on public datasets and benchmarked against other saliency models. It was found to outperform other saliency models by 6% to 30% and boost the contrast-to-noise ratio of lesions by more than 30%. Results of a perceptual study also underscore the effectiveness and, hence, the potential of ALES as an assistive tool for readers. PMID:28560245

  5. Screen printed flexible radiofrequency identification tag for oxygen monitoring.

    PubMed

    Martínez-Olmos, A; Fernández-Salmerón, J; Lopez-Ruiz, N; Rivadeneyra Torres, A; Capitan-Vallvey, L F; Palma, A J

    2013-11-19

    In this work, a radiofrequency identification (RFID) tag with an optical indicator for the measurement of gaseous oxygen is described. It consists of an O2 sensing membrane of PtOEP together with a full electronic system for RFID communication, all printed on a flexible substrate. The membrane is excited by an LED at 385 nm wavelength and the intensity of the luminescence generated is registered by means of a digital color detector. The output data corresponding to the red coordinate of the RGB color space is directly related to the concentration of O2, and it is sent to a microcontroller. The RFID tag is designed and implemented by screen printing on a flexible substrate for the wireless transmission of the measurement to a remote reader. It can operate in both active and passive mode, obtaining the power supply from the electromagnetic waves of the RFID reader or from a small battery, respectively. This system has been fully characterized and calibrated including temperature drifts, showing a high-resolution performance that allows measurement of very low values of oxygen content. Therefore this system is perfectly suitable for its use in modified atmosphere packaging where the oxygen concentration is reduced below 2%. As the reading of the O2 concentration inside the envelope is carried out with an external RFID reader using wireless communication, there is no need for perforations for probes or wires, so the packaging remains completely closed. With the presented device, a limit of detection of 40 ppm and a resolution as low as 0.1 ppm of O2 can be reached with a low power consumption of 3.55 mA.

  6. Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue.

    PubMed

    Jiang, Yulei; Inciardi, Marc F; Edwards, Alexandra V; Papaioannou, John

    2018-05-24

    The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.

  7. Virtual screening using MTiOpenScreen and PyRx 0,8 revealed ZINC95486216 as a human acetylcholinesterase inhibitor candidate

    NASA Astrophysics Data System (ADS)

    Sulistyo Dwi K., P.; Arindra Trisna, W.; Vindri Catur P., W.; Wijayanti, Erna; Ichsan, Mochammad

    2016-03-01

    One of the efforts to prevent Alzheimer's disease becomes more severe is by inhibiting the activity of Human acetylcholinesterase enzyme (PDB ID: 4BDT). In this study, virtual screening againts 885 natural compounds from AfroDB has been done using MTIOpenScreen and this step has been successful in identifying ZINC15121024 (-12,9) and ZINC95486216 (-12,7) as the top rank compounds. This data then strengthened by the results of second docking step using Autodock software that has been integrated in PyRx 0.8 software. From this stage, ZINC95486216 (-11,3 kcal/mol) is a compound with the most negative binding affinity compared with four Alzheimer's drugs that have been officially used to date including Rivastigmine (-6,3 Kcal/mol), Donepenzil (-7.9 kcal/mol), Galantamine (-8.4 kcal/mol), and Huprine W (-7.3 kcal/mol). In addition, based on the results of the 2D and 3D visualization using LigPlus and PyMol softwares, respectively, known that the five compounds above are equally capable of binding to several amino acids (Trp 286, Phe295, and Tyr341) located in the active site of Human Acetylcholinesterase enzyme.

  8. The Analysis of Fourth Grade Primary Students' Reader Self-Perceptions in Terms of Gender and Preschool Educational Background

    ERIC Educational Resources Information Center

    Sagirli, Muhittin; Okur, Burçin

    2017-01-01

    The aim of this study was to analyse perceptions of fourth grade primary school students on their reading ability. In study, screening model was used as a quantitative research method. The sample of this research was selected by convenience sampling. The sample consisted of 556 fourth grade students who received education in 8 public schools in…

  9. Understanding On-Screen Reading Behaviors in Academic Contexts: A Case Study of Five Graduate English-as-a-Second-Language Students

    ERIC Educational Resources Information Center

    Chou, I-Chia

    2012-01-01

    Undoubtedly, new areas of functionality for electronic texts will come to the fore and create new reading habits and expectations for dealing and interacting with text as electronic texts become dominant in the academic world. These new forms of reading will gradually become as natural as the different activities readers now take for granted, such…

  10. The Evolution of Reading in the Age of Digitisation: An Integrative Framework for Reading Research

    ERIC Educational Resources Information Center

    Mangen, Anne; Weel, Adriaan

    2016-01-01

    In the course of digitisation, the range of substrates for textual reading is being expanded to include a number of screen-based technologies and reading devices, such as e-readers (e.g. Kindle) and tablets (e.g. iPad). These technologies have distinctly different affordances than paper has. Given that textual reading is at the same time likely to…

  11. DOVIS 2.0: an efficient and easy to use parallel virtual screening tool based on AutoDock 4.0.

    PubMed

    Jiang, Xiaohui; Kumar, Kamal; Hu, Xin; Wallqvist, Anders; Reifman, Jaques

    2008-09-08

    Small-molecule docking is an important tool in studying receptor-ligand interactions and in identifying potential drug candidates. Previously, we developed a software tool (DOVIS) to perform large-scale virtual screening of small molecules in parallel on Linux clusters, using AutoDock 3.05 as the docking engine. DOVIS enables the seamless screening of millions of compounds on high-performance computing platforms. In this paper, we report significant advances in the software implementation of DOVIS 2.0, including enhanced screening capability, improved file system efficiency, and extended usability. To keep DOVIS up-to-date, we upgraded the software's docking engine to the more accurate AutoDock 4.0 code. We developed a new parallelization scheme to improve runtime efficiency and modified the AutoDock code to reduce excessive file operations during large-scale virtual screening jobs. We also implemented an algorithm to output docked ligands in an industry standard format, sd-file format, which can be easily interfaced with other modeling programs. Finally, we constructed a wrapper-script interface to enable automatic rescoring of docked ligands by arbitrarily selected third-party scoring programs. The significance of the new DOVIS 2.0 software compared with the previous version lies in its improved performance and usability. The new version makes the computation highly efficient by automating load balancing, significantly reducing excessive file operations by more than 95%, providing outputs that conform to industry standard sd-file format, and providing a general wrapper-script interface for rescoring of docked ligands. The new DOVIS 2.0 package is freely available to the public under the GNU General Public License.

  12. Space Telecommunications Radio System (STRS) Definitions and Acronyms

    NASA Technical Reports Server (NTRS)

    Briones, Janette C.; Handler, Louis M.; Johnson, Sandra K.; Nappier, Jennifer; Gnepp, Steven; Kacpura, Thomas J.; Reinhart, Richard C.; Hall, Charles S.; Mortensen, Dale

    2008-01-01

    Software-defined radio is a relatively new technology area, and industry consensus on terminology is not always consistent. Confusion exists when the various organizations and standards bodies define different radio terms associated with the actual amount of reconfigurability of the radios. The Space Telecommunications Radio System (STRS) Definitions and Acronyms Document provides the readers of the STRS documents a common understanding of the terminology used and how they will be applied to the STRS architecture.

  13. Integrating Distributed Interactive Simulations With the Project Darkstar Open-Source Massively Multiplayer Online Game (MMOG) Middleware

    DTIC Science & Technology

    2009-09-01

    be complete MMOG solutions such as Multiverse are not within the scope of this thesis, though it is recommended that readers compare this type of...software to the middleware described here ( Multiverse , 2009). 1. University of Munster: Real-Time Framework The Real-Time Framework (RTF) project is...10, 2009, from http://wiki.secondlife.com/wiki/MMOX Multiverse . (2009). Multiverse platform architecture. Retrieved September 9, 2009, from http

  14. Evaluating and Mitigating Software Supply Chain Security Risks

    DTIC Science & Technology

    2010-05-01

    is returned for all employees. The risk associated with this defect is high; variants of it have been used in attacks that caused credit card data to...via Common Access Card (CAC) readers). 29 | CMU/SEI-2010-TN-016 4.2.1 Supplier Capability Because the project is already in development, the...ClearCase, Windows, Linux and Solaris, network administration, TCP/IP, X/Motif, DII COE, Simple Net- work Management Protocol (SNMP), Agent Technology

  15. Assessing the Acceptance and Functional Value of the Asymmetrical Software Kit (ASK) at the Tactical Level

    DTIC Science & Technology

    2007-12-01

    www.istheory.yorku.ca/theoryofreasonedaction.htm on 07 Dec 2007. 28 I . Ajzen , Residual Effects of Past on Later Behavior: Habituation and Reasoned...for Intelligence analysis at the Tactical level. 51 LIST OF REFERENCES Ajzen , I ., Residual Effects of Past on Later Behavior: Habituation and...Advisor: Douglas Borer Second Reader: Richard Bergin THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188

  16. Building a Better Model: A Comprehensive Breast Cancer Risk Model Incorporating Breast Density to Stratify Risk and Apply Resources

    DTIC Science & Technology

    2014-10-01

    variability with well trained readers. Figure 7: comparison between the PD (percent density using Cumulus area) and the automatic PD. The...evaluation of outlier correction, comparison of several different software methods, precision measurement, and evaluation of variation by mammography...chart review for selected cases (month 4-6). Comparison of information from the Breast Cancer Database and medical records showed good consistency

  17. Coronal and Intraradicular Appearances Affect Radiographic Perception of the Periapical Region.

    PubMed

    Strong, Julie W; Woodmansey, Karl F; Khademi, John A; Hatton, John F

    2017-05-01

    The influence of the radiographic appearances of the coronal and intraradicular areas on periapical radiographic interpretation has been minimally evaluated in dentistry and endodontics. The purpose of this study was to evaluate the effects that the coronal and intraradicular radiographic appearance has on endodontists' radiographic interpretations of periapical areas. In a split-group study design using an online survey format, 2 pairs of digital periapical radiographic images were evaluated by 2 groups (A and B) of endodontist readers for the presence of a periapical finding. The images in each pair were identical except that 1 image of each image pairs had coronal restorations and/or root canal fillings altered using Adobe Photoshop software (Adobe Systems, San Jose, CA). The periapical areas were not altered. Using a 5-point Likert scale, the endodontist readers were asked to "Please evaluate the periapical area(s)." A Mann-Whitney U test was used to statistically evaluate the difference between the groups. Significance was set at P < .01. There were 417 readers in group A and 442 readers in group B. The Mann-Whitney U test showed a significant difference in the responses between the groups for both image pairs (P < .01). Because the periapical areas of the image pairs were unaltered, the differing coronal and intraradicular areas of the radiographs appear to have influenced endodontists' interpretations of the periapical areas. This finding has implications for all radiographic outcome assessments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Applying Minimal Manual Principles for Documentation of Graphical User Interfaces.

    ERIC Educational Resources Information Center

    Nowaczyk, Ronald H.; James, E. Christopher

    1993-01-01

    Investigates the need to include computer screens in documentation for software using a graphical user interface. Describes the uses and purposes of "minimal manuals" and their principles. Studies student reaction to their use of one of three on-screen manuals: screens, icon, and button. Finds some benefit for including icon and button…

  19. Designing a Visual Factors-Based Screen Display Interface: The New Role of the Graphic Technologist.

    ERIC Educational Resources Information Center

    Faiola, Tony; DeBloois, Michael L.

    1988-01-01

    Discusses the role of the graphic technologist in preparing computer screen displays for interactive videodisc systems, and suggests screen design guidelines. Topics discussed include the grid system; typography; visual factors research; color; course mobility through branching and software menus; and a model of course integration. (22 references)…

  20. Comparison of requirements and capabilities of major multipurpose software packages.

    PubMed

    Igo, Robert P; Schnell, Audrey H

    2012-01-01

    The aim of this chapter is to introduce the reader to commonly used software packages and illustrate their input requirements, analysis options, strengths, and limitations. We focus on packages that perform more than one function and include a program for quality control, linkage, and association analyses. Additional inclusion criteria were (1) programs that are free to academic users and (2) currently supported, maintained, and developed. Using those criteria, we chose to review three programs: Statistical Analysis for Genetic Epidemiology (S.A.G.E.), PLINK, and Merlin. We will describe the required input format and analysis options. We will not go into detail about every possible program in the packages, but we will give an overview of the packages requirements and capabilities.

  1. Tabular data and graphical images in support of the U.S. Geological Survey National Oil and Gas Assessment -- San Joaquin Basin (5010): Chapter 28 in Petroleum systems and geologic assessment of oil and gas in the San Joaquin Basin Province, California

    USGS Publications Warehouse

    Klett, T.R.; Le, P.A.

    2007-01-01

    This chapter describes data used in support of the assessment process. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD–ROM. Computers and software may import the data without transcription from the portable document format (.pdf) files of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).

  2. Chapter 2: Tabular Data and Graphical Images in Support of the U.S. Geological Survey National Oil and Gas Assessment - The Wind River Basin Province

    USGS Publications Warehouse

    Klett, T.R.; Le, P.A.

    2007-01-01

    This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files) because of the number and variety of platforms and software available.

  3. Augmented Reality in Scientific Publications-Taking the Visualization of 3D Structures to the Next Level.

    PubMed

    Wolle, Patrik; Müller, Matthias P; Rauh, Daniel

    2018-03-16

    The examination of three-dimensional structural models in scientific publications allows the reader to validate or invalidate conclusions drawn by the authors. However, either due to a (temporary) lack of access to proper visualization software or a lack of proficiency, this information is not necessarily available to every reader. As the digital revolution is quickly progressing, technologies have become widely available that overcome the limitations and offer to all the opportunity to appreciate models not only in 2D, but also in 3D. Additionally, mobile devices such as smartphones and tablets allow access to this information almost anywhere, at any time. Since access to such information has only recently become standard practice, we want to outline straightforward ways to incorporate 3D models in augmented reality into scientific publications, books, posters, and presentations and suggest that this should become general practice.

  4. Evaluating the decision accuracy and speed of clinical data visualizations.

    PubMed

    Pieczkiewicz, David S; Finkelstein, Stanley M

    2010-01-01

    Clinicians face an increasing volume of biomedical data. Assessing the efficacy of systems that enable accurate and timely clinical decision making merits corresponding attention. This paper discusses the multiple-reader multiple-case (MRMC) experimental design and linear mixed models as means of assessing and comparing decision accuracy and latency (time) for decision tasks in which clinician readers must interpret visual displays of data. These tools can assess and compare decision accuracy and latency (time). These experimental and statistical techniques, used extensively in radiology imaging studies, offer a number of practical and analytic advantages over more traditional quantitative methods such as percent-correct measurements and ANOVAs, and are recommended for their statistical efficiency and generalizability. An example analysis using readily available, free, and commercial statistical software is provided as an appendix. While these techniques are not appropriate for all evaluation questions, they can provide a valuable addition to the evaluative toolkit of medical informatics research.

  5. Introduction to multifractal detrended fluctuation analysis in matlab.

    PubMed

    Ihlen, Espen A F

    2012-01-01

    Fractal structures are found in biomedical time series from a wide range of physiological phenomena. The multifractal spectrum identifies the deviations in fractal structure within time periods with large and small fluctuations. The present tutorial is an introduction to multifractal detrended fluctuation analysis (MFDFA) that estimates the multifractal spectrum of biomedical time series. The tutorial presents MFDFA step-by-step in an interactive Matlab session. All Matlab tools needed are available in Introduction to MFDFA folder at the website www.ntnu.edu/inm/geri/software. MFDFA are introduced in Matlab code boxes where the reader can employ pieces of, or the entire MFDFA to example time series. After introducing MFDFA, the tutorial discusses the best practice of MFDFA in biomedical signal processing. The main aim of the tutorial is to give the reader a simple self-sustained guide to the implementation of MFDFA and interpretation of the resulting multifractal spectra.

  6. Introduction to Multifractal Detrended Fluctuation Analysis in Matlab

    PubMed Central

    Ihlen, Espen A. F.

    2012-01-01

    Fractal structures are found in biomedical time series from a wide range of physiological phenomena. The multifractal spectrum identifies the deviations in fractal structure within time periods with large and small fluctuations. The present tutorial is an introduction to multifractal detrended fluctuation analysis (MFDFA) that estimates the multifractal spectrum of biomedical time series. The tutorial presents MFDFA step-by-step in an interactive Matlab session. All Matlab tools needed are available in Introduction to MFDFA folder at the website www.ntnu.edu/inm/geri/software. MFDFA are introduced in Matlab code boxes where the reader can employ pieces of, or the entire MFDFA to example time series. After introducing MFDFA, the tutorial discusses the best practice of MFDFA in biomedical signal processing. The main aim of the tutorial is to give the reader a simple self-sustained guide to the implementation of MFDFA and interpretation of the resulting multifractal spectra. PMID:22675302

  7. Applied and implied semantics in crystallographic publishing

    PubMed Central

    2012-01-01

    Background Crystallography is a data-rich, software-intensive scientific discipline with a community that has undertaken direct responsibility for publishing its own scientific journals. That community has worked actively to develop information exchange standards allowing readers of structure reports to access directly, and interact with, the scientific content of the articles. Results Structure reports submitted to some journals of the International Union of Crystallography (IUCr) can be automatically validated and published through an efficient and cost-effective workflow. Readers can view and interact with the structures in three-dimensional visualization applications, and can access the experimental data should they wish to perform their own independent structure solution and refinement. The journals also layer on top of this facility a number of automated annotations and interpretations to add further scientific value. Conclusions The benefits of semantically rich information exchange standards have revolutionised the scholarly publishing process for crystallography, and establish a model relevant to many other physical science disciplines. PMID:22932420

  8. Tutorial: Crystal orientations and EBSD — Or which way is up?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Britton, T.B., E-mail: b.britton@imperial.ac.uk; Jiang, J.; Guo, Y.

    2016-07-15

    Electron backscatter diffraction (EBSD) is an automated technique that can measure the orientation of crystals in a sample very rapidly. There are many sophisticated software packages that present measured data. Unfortunately, due to crystal symmetry and differences in the set-up of microscope and EBSD software, there may be accuracy issues when linking the crystal orientation to a particular microstructural feature. In this paper we outline a series of conventions used to describe crystal orientations and coordinate systems. These conventions have been used to successfully demonstrate that a consistent frame of reference is used in the sample, unit cell, pole figuremore » and diffraction pattern frames of reference. We establish a coordinate system rooted in measurement of the diffraction pattern and subsequently link this to all other coordinate systems. A fundamental outcome of this analysis is to note that the beamshift coordinate system needs to be precisely defined for consistent 3D microstructure analysis. This is supported through a series of case studies examining particular features of the microscope settings and/or unambiguous crystallographic features. These case studies can be generated easily in most laboratories and represent an opportunity to demonstrate confidence in use of recorded orientation data. Finally, we include a simple software tool, written in both MATLAB® and Python, which the reader can use to compare consistency with their own microscope set-up and which may act as a springboard for further offline analysis. - Highlights: • Presentation of conventions used to describe crystal orientations • Three case studies that outline how conventions are consistent • Demonstrates a pathway for calibration and validation of EBSD based orientation measurements • EBSD computer code supplied for validation by the reader.« less

  9. Utility of hand-held devices in diagnosis and triage of cardiovascular emergencies. Observations during implementation of a PACS-based system in an acute aortic syndrome (AAS) network.

    PubMed

    Matar, Ralph; Renapurkar, Rahul; Obuchowski, Nancy; Menon, Venu; Piraino, David; Schoenhagen, Paul

    2015-01-01

    Prompt diagnosis and early referral to specialized centers is critical for patients presenting with cardiovascular emergencies, including acute aortic syndromes (AAS). Prior data has suggested that mobile access to imaging studies with hand-held devices can accelerate diagnosis and management. We conducted a study to determine the diagnostic accuracy of a hand-held device compared to conventional dedicated work-stations for diagnosing a spectrum of cardiovascular emergencies, predominantly acute aortic pathology. This study included 104 cases who underwent computed tomography (CT)-scan during "on-call'' hours between January, 2013 and August, 2014 for suspected AAS. Assessment was performed on a hand-held device independently by two readers using an iPhone5 connected via secure connection to web-based PACS servers. The subsequent interpretation from a dedicated workstation coupled with the diagnosis at the time of discharge was used as the reference standard for determining the presence or absence of an acute abnormality. Sensitivity and Specificity were calculated on a per patient basis. Readers' sensitivity and specificity using the hand-held device to diagnose acute chest pathology were calculated. Hand-held device evaluation was determined to have a sensitivity of 85.2% and a specificity of 98.6% by reader A and a sensitivity of 96.3% and specificity of 100% by reader B. Of 103 cases interpreted by both readers, the readers agreed about the diagnosis in 98 cases (95.1%). This study demonstrates that hand-held devices can be a potential useful tool to assist in diagnosis and triage of patients presenting with cardiovascular emergencies. Further studies are needed to assess the impact of screen size and resolution. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Multi-modality 3D breast imaging with X-Ray tomosynthesis and automated ultrasound.

    PubMed

    Sinha, Sumedha P; Roubidoux, Marilyn A; Helvie, Mark A; Nees, Alexis V; Goodsitt, Mitchell M; LeCarpentier, Gerald L; Fowlkes, J Brian; Chalek, Carl L; Carson, Paul L

    2007-01-01

    This study evaluated the utility of 3D automated ultrasound in conjunction with 3D digital X-Ray tomosynthesis for breast cancer detection and assessment, to better localize and characterize lesions in the breast. Tomosynthesis image volumes and automated ultrasound image volumes were acquired in the same geometry and in the same view for 27 patients. 3 MQSA certified radiologists independently reviewed the image volumes, visually correlating the images from the two modalities with in-house software. More sophisticated software was used on a smaller set of 10 cases, which enabled the radiologist to draw a 3D box around the suspicious lesion in one image set and isolate an anatomically correlated, similarly boxed region in the other modality image set. In the primary study, correlation was found to be moderately useful to the readers. In the additional study, using improved software, the median usefulness rating increased and confidence in localizing and identifying the suspicious mass increased in more than half the cases. As automated scanning and reading software techniques advance, superior results are expected.

  11. Cost-effective and business-beneficial computer validation for bioanalytical laboratories.

    PubMed

    McDowall, Rd

    2011-07-01

    Computerized system validation is often viewed as a burden and a waste of time to meet regulatory requirements. This article presents a different approach by looking at validation in a bioanalytical laboratory from the business benefits that computer validation can bring. Ask yourself the question, have you ever bought a computerized system that did not meet your initial expectations? This article will look at understanding the process to be automated, the paper to be eliminated and the records to be signed to meet the requirements of the GLP or GCP and Part 11 regulations. This paper will only consider commercial nonconfigurable and configurable software such as plate readers and LC-MS/MS data systems rather than LIMS or custom applications. Two streamlined life cycle models are presented. The first one consists of a single document for validation of nonconfigurable software. The second is for configurable software and is a five-stage model that avoids the need to write functional and design specifications. Both models are aimed at managing the risk each type of software poses whist reducing the amount of documented evidence required for validation.

  12. Evaluation of Screening for Retinopathy of Prematurity by ROPtool or a Lay Reader.

    PubMed

    Abbey, Ashkan M; Besirli, Cagri G; Musch, David C; Andrews, Chris A; Capone, Antonio; Drenser, Kimberly A; Wallace, David K; Ostmo, Susan; Chiang, Michael; Lee, Paul P; Trese, Michael T

    2016-02-01

    To determine if (1) tortuosity assessment by a computer program (ROPtool, developed at the University of North Carolina, Chapel Hill, and Duke University, and licensed by FocusROP) that traces retinal blood vessels and (2) assessment by a lay reader are comparable with assessment by a panel of 3 retinopathy of prematurity (ROP) experts for remote clinical grading of vascular abnormalities such as plus disease. Validity and reliability analysis of diagnostic tools. Three hundred thirty-five fundus images of prematurely born infants. Three hundred thirty-five fundus images of prematurely born infants were obtained by neonatal intensive care unit nurses. A panel of 3 ROP experts graded 84 images showing vascular dilatation, tortuosity, or both and 251 images showing no evidence of vascular abnormalities. These images were sent electronically to an experienced lay reader who independently graded them for vascular abnormalities. The images also were analyzed using the ROPtool, which assigns a numerical value to the level of vascular abnormality and tortuosity present in each of 4 quadrants or sectors. The ROPtool measurements of vascular abnormalities were graded and compared with expert panel grades with a receiver operating characteristic (ROC) curve. Grades between human readers were cross-tabulated. The area under the ROC curve was calculated for the ROPtool, and sensitivity and specificity were computed for the lay reader. Measurements of vascular abnormalities by ROPtool and grading of vascular abnormalities by 3 ROP experts and 1 experienced lay reader. The ROC curve for ROPtool's tortuosity assessment had an area under the ROC curve of 0.917. Using a threshold value of 4.97 for the second most tortuous quadrant, ROPtool's sensitivity was 91% and its specificity was 82%. Lay reader sensitivity and specificity were 99% and 73%, respectively, and had high reliability (κ, 0.87) in repeated measurements. ROPtool had very good accuracy for detection of vascular abnormalities suggestive of plus disease when compared with expert physician graders. The lay reader's results showed excellent sensitivity and good specificity when compared with those of the expert graders. These options for remote reading of images to detect vascular abnormalities deserve consideration in the quest to use telemedicine with remote reading for efficient delivery of high-quality care and to detect infants requiring bedside examination. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heusinkveld, Harm J.; Westerink, Remco H.S., E-mail: R.Westerink@uu.nl

    Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca{sup 2+}]{sub i}, e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca{sup 2+}]{sub i} are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca{sup 2+}]{sub i} in plate reader systems, though the results of such plate reader-based measurements have beenmore » questioned. In view of the increasing use of plate reader systems for measurements of [Ca{sup 2+}]{sub i} a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca{sup 2+}]{sub i}. Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with caveats and limitations that require further investigation. - Research Highlights: > The use of plate readers for high-throughput screening of intracellular Ca{sup 2+} is associated with many pitfalls and limitations. > Single cell fluorescent microscopy is recommended for measurements of intracellular Ca{sup 2+}. > Dual-wavelength dyes (Fura-2) are preferred over single-wavelength dyes (Fluo-4) for measurements of intracellular Ca{sup 2+}. > Probenecid prevents dye leakage but abolishes depolarization-evoked Ca{sup 2+} influx, severely hampering measurements of Ca{sup 2+}. > In general, care should be taken when interpreting data from high-throughput kinetic measurements.« less

  14. A review of radio frequency identification technology for the anatomic pathology or biorepository laboratory: Much promise, some progress, and more work needed.

    PubMed

    Lou, Jerry J; Andrechak, Gary; Riben, Michael; Yong, William H

    2011-01-01

    Patient safety initiatives throughout the anatomic laboratory and in biorepository laboratories have mandated increasing emphasis on the need for accurately identifying and tracking biospecimen assets throughout their production lifecycle and for archiving/retrieval purposes. However, increasing production volume along with complex workflow characteristics, reliance on manual production processes, and required asset movement to disparate destinations throughout asset lifecycles continue to challenge laboratory efforts. Radio Frequency Identification (RFID) technology, use of radio waves to communicate data between electronic tags attached to objects and a reader, shows significant potential to facilitate and overcome these hurdles. Advantages over traditional barcode labeling include readability without direct line-of-sight alignment to the reader, ability to read multiple tags simultaneously, higher data storage capacity, faster data transmission rate, and capacity to perform multiple read-writes of data to the tag. Most importantly, use of radio waves decreases the need to manually scan each asset, and at each step, identification or tracking event is needed. Temperature monitoring by on-board sensors and three-dimensional position tracking are additional potential benefits of using RFID technology. To date, barriers to implementation of RFID systems in the anatomic laboratory include increased associated costs of tags and readers, system software, data security concerns, lack of specific data standards for stored information, and potential for technological obsolescence during decades of specimen storage. Novel RFID production techniques and increased production capacity are projected to lower costs of some tags to a few cents each. Potentially, information security concerns can be addressed by techniques such as shielding, data encryption, and tag pseudonyms. Commitment by stakeholder groups to develop RFID tag data standards for anatomic pathology and biorepository laboratories could avoid or mitigate the "islands of data" dilemma presented by barcode usage where there are innumerable standards and a consequent paucity of hardware or software "plug and play" interoperability. Work remains to be done to establish the durability and appropriate shielding of individual tag types for use in harsh laboratory environmental conditions, and for long-term archival storage. Finally, given the requirements for long-term storage of biospecimen assets, consideration should be given to ways of mitigating data isolation due to eventual technological obsolescence of a particular RFID technology or software.

  15. A review of radio frequency identification technology for the anatomic pathology or biorepository laboratory: Much promise, some progress, and more work needed

    PubMed Central

    Lou, Jerry J.; Andrechak, Gary; Riben, Michael; Yong, William H.

    2011-01-01

    Patient safety initiatives throughout the anatomic laboratory and in biorepository laboratories have mandated increasing emphasis on the need for accurately identifying and tracking biospecimen assets throughout their production lifecycle and for archiving/retrieval purposes. However, increasing production volume along with complex workflow characteristics, reliance on manual production processes, and required asset movement to disparate destinations throughout asset lifecycles continue to challenge laboratory efforts. Radio Frequency Identification (RFID) technology, use of radio waves to communicate data between electronic tags attached to objects and a reader, shows significant potential to facilitate and overcome these hurdles. Advantages over traditional barcode labeling include readability without direct line-of-sight alignment to the reader, ability to read multiple tags simultaneously, higher data storage capacity, faster data transmission rate, and capacity to perform multiple read-writes of data to the tag. Most importantly, use of radio waves decreases the need to manually scan each asset, and at each step, identification or tracking event is needed. Temperature monitoring by on-board sensors and three-dimensional position tracking are additional potential benefits of using RFID technology. To date, barriers to implementation of RFID systems in the anatomic laboratory include increased associated costs of tags and readers, system software, data security concerns, lack of specific data standards for stored information, and potential for technological obsolescence during decades of specimen storage. Novel RFID production techniques and increased production capacity are projected to lower costs of some tags to a few cents each. Potentially, information security concerns can be addressed by techniques such as shielding, data encryption, and tag pseudonyms. Commitment by stakeholder groups to develop RFID tag data standards for anatomic pathology and biorepository laboratories could avoid or mitigate the “islands of data” dilemma presented by barcode usage where there are innumerable standards and a consequent paucity of hardware or software “plug and play” interoperability. Work remains to be done to establish the durability and appropriate shielding of individual tag types for use in harsh laboratory environmental conditions, and for long-term archival storage. Finally, given the requirements for long-term storage of biospecimen assets, consideration should be given to ways of mitigating data isolation due to eventual technological obsolescence of a particular RFID technology or software. PMID:21886890

  16. Magnetic Resonance Imaging in Patients With Mechanical Low Back Pain Using a Novel Rapid-Acquisition Three-Dimensional SPACE Sequence at 1.5-T: A Pilot Study Comparing Lumbar Stenosis Assessment With Routine Two-Dimensional Magnetic Resonance Sequences.

    PubMed

    Swami, Vimarsha G; Katlariwala, Mihir; Dhillon, Sukhvinder; Jibri, Zaid; Jaremko, Jacob L

    2016-11-01

    To minimize the burden of overutilisation of lumbar spine magnetic resonance imaging (MRI) on a resource-constrained public healthcare system, it may be helpful to image some patients with mechanical low-back pain (LBP) using a simplified rapid MRI screening protocol at 1.5-T. A rapid-acquisition 3-dimensional (3D) SPACE (Sampling Perfection with Application-optimized Contrasts using different flip angle Evolution) sequence can demonstrate common etiologies of LBP. We compared lumbar spinal canal stenosis (LSCS) and neural foraminal stenosis (LNFS) assessment on 3D SPACE against conventional 2-dimensional (2D) MRI. We prospectively performed 3D SPACE and 2D spin-echo MRI sequences (axial or sagittal T1-weighted or T2-weighted) at 1.5-T in 20 patients. Two blinded readers assessed levels L3-4, L4-5 and L5-S1 using: 1) morphologic grading systems, 2) global impression on the presence or absence of clinically significant stenosis (n = 60 disc levels for LSCS, n = 120 foramina for LNFS). Reliability statistics were calculated. Acquisition time was ∼5 minutes for SPACE and ∼20 minutes for 2D MRI sequences. Interobserver agreement of LSCS was substantial to near perfect on both sequences (morphologic grading: kappa [k] = 0.71 SPACE, k = 0.69 T2-weighted; global impression: k = 0.85 SPACE, k = 0.78 T2-weighted). LNFS assessment had superior interobserver reliability using SPACE than T1-weighted (k = 0.54 vs 0.37). Intersequence agreement of findings between SPACE and 2D MRI was substantial to near perfect by global impression (LSCS: k = 0.78 Reader 1, k = 0.85 Reader 2; LNFS: k = 0.63 Reader 1, k = 0.66 Reader 2). 3D SPACE was acquired in one-quarter the time as the conventional 2D MRI protocol, had excellent agreement with 2D MRI for stenosis assessment, and had interobserver reliability superior to 2D MRI. These results justify future work to explore the role of 3D SPACE in a rapid MRI screening protocol at 1.5-T for mechanical LBP. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. A comparison of image interpretation times in full field digital mammography and digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Astley, Susan; Connor, Sophie; Lim, Yit; Tate, Catriona; Entwistle, Helen; Morris, Julie; Whiteside, Sigrid; Sergeant, Jamie; Wilson, Mary; Beetles, Ursula; Boggis, Caroline; Gilbert, Fiona

    2013-03-01

    Digital Breast Tomosynthesis (DBT) provides three-dimensional images of the breast that enable radiologists to discern whether densities are due to overlapping structures or lesions. To aid assessment of the cost-effectiveness of DBT for screening, we have compared the time taken to interpret DBT images and the corresponding two-dimensional Full Field Digital Mammography (FFDM) images. Four Consultant Radiologists experienced in reading FFDM images (4 years 8 months to 8 years) with training in DBT interpretation but more limited experience (137-407 cases in the past 6 months) were timed reading between 24 and 32 two view FFDM and DBT cases. The images were of women recalled from screening for further assessment and women under surveillance because of a family history of breast cancer. FFDM images were read before DBT, according to local practice. The median time for readers to interpret FFDM images was 17.0 seconds, with an interquartile range of 12.3-23.6 seconds. For DBT, the median time was 66.0 seconds, and the interquartile range was 51.1-80.5 seconds. The difference was statistically significant (p<0.001). Reading times were significantly longer in family history clinics (p<0.01). Although it took approximately four times as long to interpret DBT than FFDM images, the cases were more complex than would be expected for routine screening, and with higher mammographic density. The readers were relatively inexperienced in DBT interpretation and may increase their speed over time. The difference in times between clinics may be due to increased throughput at assessment, or decreased density.

  18. Microfluidic device for novel breast cancer screening by blood test using miRNA beacon probe.

    PubMed

    Salim, Bindu; Athira, M V; Kandaswamy, A; Vijayakumar, Madhulika; Saravanan, T; Sairam, Thiagarajan

    2017-09-30

    Breast cancer is identified as the highest cause of death in women suffering from cancer. Early diagnosis is the key to increase the survival of breast cancer victims. Molecular diagnosis using biomarkers have advanced much in the recent years. The cost involved in such diagnosis is not affordable for most of the population. The concept being investigated here is to realize a simple diagnosis system for screening cancer by way of a blood test utilizing a miRNA based biomarker with a complementary molecular beacon probe. A microfluidic platform was designed and attached with a fluorescence reader, which is portable and cost effective. Experiments were performed with 51 blood samples of which 30 were healthy and 21 were positive for breast cancer, collected against institutional human ethical clearance, IHEC 16/180-7-9-2016. miRNA 21 was chosen as the biomarker because it is overexpressed 4-fold in the serum of breast cancer patients. This work involved design of an experiment to prove the concept of miRNA over expression followed by detection of miRNA 21 using the microfluidic platform attached with a fluorescence reader and validation of the results using quantitative Real Time Polymerase Chain Reaction (qRT-PCR). The results obtained from the microfluidic device concurred with qRT-PCR results. The device is suitable for point-of-care application in a mass-screening programme. The study also has revealed that the stage of the cancer could be indicated by this test, which will be further useful for deciding a therapeutic regime.

  19. Assessment Environment for Complex Systems Software Guide

    NASA Technical Reports Server (NTRS)

    2013-01-01

    This Software Guide (SG) describes the software developed to test the Assessment Environment for Complex Systems (AECS) by the West Virginia High Technology Consortium (WVHTC) Foundation's Mission Systems Group (MSG) for the National Aeronautics and Space Administration (NASA) Aeronautics Research Mission Directorate (ARMD). This software is referred to as the AECS Test Project throughout the remainder of this document. AECS provides a framework for developing, simulating, testing, and analyzing modern avionics systems within an Integrated Modular Avionics (IMA) architecture. The purpose of the AECS Test Project is twofold. First, it provides a means to test the AECS hardware and system developed by MSG. Second, it provides an example project upon which future AECS research may be based. This Software Guide fully describes building, installing, and executing the AECS Test Project as well as its architecture and design. The design of the AECS hardware is described in the AECS Hardware Guide. Instructions on how to configure, build and use the AECS are described in the User's Guide. Sample AECS software, developed by the WVHTC Foundation, is presented in the AECS Software Guide. The AECS Hardware Guide, AECS User's Guide, and AECS Software Guide are authored by MSG. The requirements set forth for AECS are presented in the Statement of Work for the Assessment Environment for Complex Systems authored by NASA Dryden Flight Research Center (DFRC). The intended audience for this document includes software engineers, hardware engineers, project managers, and quality assurance personnel from WVHTC Foundation (the suppliers of the software), NASA (the customer), and future researchers (users of the software). Readers are assumed to have general knowledge in the field of real-time, embedded computer software development.

  20. Assembly and evaluation of a training module and dataset with feedback for improved interpretation of digital breast tomosynthesis examinations

    NASA Astrophysics Data System (ADS)

    Gur, David; Zuley, Margarita L.; Sumkin, Jules H.; Hakim, Christiane M.; Chough, Denise M.; Lovy, Linda; Sobran, Cynthia; Logue, Durwin; Zheng, Bin; Klym, Amy H.

    2012-02-01

    The FDA recently approved Digital Breast Tomosynthesis (DBT) for use in screening for the early detection of breast cancer. However, MQSA qualification for interpreting DBT through training was noted as important. Performance issues related to training are largely unknown. Therefore, we assembled a unique computerized training module to assess radiologists' performances before and after using the training module. Seventy-one actual baseline mammograms (no priors) with FFDM and DBT images were assembled to be read before and after training with the developed module. Fifty examinations of FFDM and DBT images enriched with positive findings were assembled for the training module. Depicted findings were carefully reviewed, summarized, and entered into a specially designed training database where findings were identified by case number and synchronized to the display of the related FFDM plus DBT examinations on a clinical workstation. Readers reported any findings using screening BIRADS (0, 1, or 2) followed by instantaneous feedback of the verified truth. Six radiologists participated in the study and reader average sensitivity and specificity were compared before and after training. Average sensitivity improved and specificity remained relatively the same after training. Performance changes may be affected by disease prevalence in the training set.

  1. Prete-moi Ton Logiciel pour Ecrire un Mot (Lend Me Your Software Program So I Can Write a Letter).

    ERIC Educational Resources Information Center

    Mangenot, Francois

    1993-01-01

    A brief discussion and description of one commercially available software package ("Pour Ecrire un Mot") for writing letters of various types uses the love letter as an example of the software's functioning. Answers to the prompting questions on the screen determine the few variable parameters of the text to be generated. (four…

  2. Automated image-based phenotypic analysis in zebrafish embryos

    PubMed Central

    Vogt, Andreas; Cholewinski, Andrzej; Shen, Xiaoqiang; Nelson, Scott; Lazo, John S.; Tsang, Michael; Hukriede, Neil A.

    2009-01-01

    Presently, the zebrafish is the only vertebrate model compatible with contemporary paradigms of drug discovery. Zebrafish embryos are amenable to automation necessary for high-throughput chemical screens, and optical transparency makes them potentially suited for image-based screening. However, the lack of tools for automated analysis of complex images presents an obstacle to utilizing the zebrafish as a high-throughput screening model. We have developed an automated system for imaging and analyzing zebrafish embryos in multi-well plates regardless of embryo orientation and without user intervention. Images of fluorescent embryos were acquired on a high-content reader and analyzed using an artificial intelligence-based image analysis method termed Cognition Network Technology (CNT). CNT reliably detected transgenic fluorescent embryos (Tg(fli1:EGFP)y1) arrayed in 96-well plates and quantified intersegmental blood vessel development in embryos treated with small molecule inhibitors of anigiogenesis. The results demonstrate it is feasible to adapt image-based high-content screening methodology to measure complex whole organism phenotypes. PMID:19235725

  3. Summer Research Program (1992). Summer Faculty Research Program (SFRP) Reports. Volume 4. Rome Laboratory

    DTIC Science & Technology

    1992-12-01

    cm 2 heat flux which must be transferred by the buoyancy-induced gas flow. A survey of electronic cooling literature can easily demonstrate how large...Toward Implementation of a Certification Framework for Reusable Dr. Allen S. Parrish Software Modules 15 Data Association Problems in Multisensor Data...next section and the reader is referred to [5] for additional details of the analysis. Then the method is applied to a dipole element with straight

  4. Airborne Navigation Remote Map Reader Evaluation.

    DTIC Science & Technology

    1986-03-01

    EVALUATION ( James C. Byrd Intergrated Controls/Displays Branch SAvionics Systems Division Directorate of Avionics Engineering SMarch 1986 Final Report...Resolution 15 3.2 Accuracy 15 3.3 Symbology 15 3.4 Video Standard 18 3.5 Simulator Control Box 18 3.6 Software 18 3.7 Display Performance 21 3.8 Reliability 24...can be selected depending on the detail required and will automatically be presented at his present position. .The French RMR uses a Flying Spot Scanner

  5. Incorporating 3-dimensional models in online articles.

    PubMed

    Cevidanes, Lucia H S; Ruellas, Antonio C O; Jomier, Julien; Nguyen, Tung; Pieper, Steve; Budin, Francois; Styner, Martin; Paniagua, Beatriz

    2015-05-01

    The aims of this article are to introduce the capability to view and interact with 3-dimensional (3D) surface models in online publications, and to describe how to prepare surface models for such online 3D visualizations. Three-dimensional image analysis methods include image acquisition, construction of surface models, registration in a common coordinate system, visualization of overlays, and quantification of changes. Cone-beam computed tomography scans were acquired as volumetric images that can be visualized as 3D projected images or used to construct polygonal meshes or surfaces of specific anatomic structures of interest. The anatomic structures of interest in the scans can be labeled with color (3D volumetric label maps), and then the scans are registered in a common coordinate system using a target region as the reference. The registered 3D volumetric label maps can be saved in .obj, .ply, .stl, or .vtk file formats and used for overlays, quantification of differences in each of the 3 planes of space, or color-coded graphic displays of 3D surface distances. All registered 3D surface models in this study were saved in .vtk file format and loaded in the Elsevier 3D viewer. In this study, we describe possible ways to visualize the surface models constructed from cone-beam computed tomography images using 2D and 3D figures. The 3D surface models are available in the article's online version for viewing and downloading using the reader's software of choice. These 3D graphic displays are represented in the print version as 2D snapshots. Overlays and color-coded distance maps can be displayed using the reader's software of choice, allowing graphic assessment of the location and direction of changes or morphologic differences relative to the structure of reference. The interpretation of 3D overlays and quantitative color-coded maps requires basic knowledge of 3D image analysis. When submitting manuscripts, authors can now upload 3D models that will allow readers to interact with or download them. Such interaction with 3D models in online articles now will give readers and authors better understanding and visualization of the results. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  6. Qualitative Versus Quantitative Mammographic Breast Density Assessment: Applications for the US and Abroad

    PubMed Central

    Destounis, Stamatia; Arieno, Andrea; Morgan, Renee; Roberts, Christina; Chan, Ariane

    2017-01-01

    Mammographic breast density (MBD) has been proven to be an important risk factor for breast cancer and an important determinant of mammographic screening performance. The measurement of density has changed dramatically since its inception. Initial qualitative measurement methods have been found to have limited consistency between readers, and in regards to breast cancer risk. Following the introduction of full-field digital mammography, more sophisticated measurement methodology is now possible. Automated computer-based density measurements can provide consistent, reproducible, and objective results. In this review paper, we describe various methods currently available to assess MBD, and provide a discussion on the clinical utility of such methods for breast cancer screening. PMID:28561776

  7. Clinical comparison of CR and screen film for imaging the critically ill neonate

    NASA Astrophysics Data System (ADS)

    Andriole, Katherine P.; Brasch, Robert C.; Gooding, Charles A.; Gould, Robert G.; Cohen, Pierre A.; Rencken, Ingo R.; Huang, H. K.

    1996-05-01

    A clinical comparison of computed radiography (CR) versus screen-film for imaging the critically-ill neonate is performed, utilizing a modified (hybrid) film cassette containing a CR (standard ST-V) imaging plate, a conventional screen and film, allowing simultaneous acquisition of perfectly matched CR and plain film images. For 100 portable neonatal chest and abdominal projection radiographs, plain film was subjectively compared to CR hardcopy. Three pediatric radiologists graded overall image quality on a scale of one (poor) to five (excellent), as well as visualization of various anatomic structures (i.e., lung parenchyma, pulmonary vasculature, tubes/lines) and pathological findings (i.e., pulmonary interstitial emphysema, pleural effusion, pneumothorax). Results analyzed using a combined kappa statistic of the differences between scores from each matched set, combined over the three readers showed no statistically significant difference in overall image quality between screen- film and CR (p equals 0.19). Similarly, no statistically significant difference was seen between screen-film and CR for anatomic structure visualization and for visualization of pathological findings. These results indicate that the image quality of CR is comparable to plain film, and that CR may be a suitable alternative to screen-film imaging for portable neonatal chest and abdominal examinations.

  8. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.

  9. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices

    NASA Astrophysics Data System (ADS)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.

  10. Molecular Modeling on the PC (by Matthew F. Schlecht)

    NASA Astrophysics Data System (ADS)

    Rioux, Reviewed Frank

    2000-06-01

    "Computeraided molecular modeling doesn't exist for its own sake, but to contribute to scientific endeavor, and enable the scientist to work smarter." This is the last sentence of Schlecht's preface and it says something very important about contemporary scientific research in the academic and industrial venues. Owing to the accelerating improvement in computer technology (hardware and software) and its widespread availability, molecular modeling has become a reliable and important tool in chemical research. Consequently, experimentalists have incorporated molecular modeling techniques in their research, and partnerships with computational chemists have become common. This is a wellorganized and thorough monograph that devotes its attention to one type of molecular modeling, molecular mechanics, and one molecular modeling software package, PCMODEL. Schlecht targets two reader-user groups, the novice and the journeyman modeler, and articulates three goals. He wants to provide the novice with an introduction to molecular mechanics, and after that with some practical examples of the use of empirical force field calculations. His third goal is to provide the journeyman modeler with a reference work that will aid "further study and practice". These are potentially conflicting goals, but Schlecht is, in my opinion, successful because of the way his book is organized. A comprehensive treatment such as this one is not meant to be read from cover to cover, because it is both an exposition of basic principles and a user's manual. Therefore, the novice and the experienced modeler will undoubtedly use this book in different ways. For example, a novice modeler might be advised to read the Preface and Chapter 1, which together provide a broad introduction to the historical development and goals of molecular mechanics. From there the novice could go to Chapter 5 and read section 5.1 on the components of the molecular mechanics force field, which is presented in 22 pages with plenty of graphical support. The reader is now ready to move to Chapter 6 on applications and work through the 32 exercises (Chapters 3 and 4 have an additional 11 exercises) designed to illustrate the current uses of molecular modeling in academic and industrial research. Chapter 3 (Input and Output), Chapter 4 (File Formats), and the balance of Chapter 5 can be consulted as needed. For example, Chapter 5 contains 160 pages on the evolution of the various empirical force fields in use today and important information in each case on parameterization and implementation. Besides finding a clearly written, wellorganized, thorough presentation, the reader will appreciate a number of other important features. There are numerous references (993) to the primary literature covering the field of molecular mechanics from its beginnings to mid1997, when the book went to press. There is a complete glossary of PCMODEL commands, and a comprehensive and valuable glossary (77 pages) of frequently used computer terms. There are 392 figures (many of them screen captures) providing illustrations of the PCMODEL interface in use and examples of input and output files. To aid the reader/user in obtaining expertise as a modeler, a diskette containing all the structure files for all the exercises accompanies the text. In addition, the author provides, on the same diskette, a browserreadable HTML file that contains links to a large number of pertinent resources on the World Wide Web. In summary, Molecular Modeling on the PC, by Matthew Schlecht, is a very impressive contribution to the molecular modeling literature. Schlecht's book should be in every college and university library and in the personal libraries of those who want to learn more about molecular mechanics or who anticipate its use in their teaching or research.

  11. Effects of Iterative Reconstruction Algorithms on Computer-assisted Detection (CAD) Software for Lung Nodules in Ultra-low-dose CT for Lung Cancer Screening.

    PubMed

    Nomura, Yukihiro; Higaki, Toru; Fujita, Masayo; Miki, Soichiro; Awaya, Yoshikazu; Nakanishi, Toshio; Yoshikawa, Takeharu; Hayashi, Naoto; Awai, Kazuo

    2017-02-01

    This study aimed to evaluate the effects of iterative reconstruction (IR) algorithms on computer-assisted detection (CAD) software for lung nodules in ultra-low-dose computed tomography (ULD-CT) for lung cancer screening. We selected 85 subjects who underwent both a low-dose CT (LD-CT) scan and an additional ULD-CT scan in our lung cancer screening program for high-risk populations. The LD-CT scans were reconstructed with filtered back projection (FBP; LD-FBP). The ULD-CT scans were reconstructed with FBP (ULD-FBP), adaptive iterative dose reduction 3D (AIDR 3D; ULD-AIDR 3D), and forward projected model-based IR solution (FIRST; ULD-FIRST). CAD software for lung nodules was applied to each image dataset, and the performance of the CAD software was compared among the different IR algorithms. The mean volume CT dose indexes were 3.02 mGy (LD-CT) and 0.30 mGy (ULD-CT). For overall nodules, the sensitivities of CAD software at 3.0 false positives per case were 78.7% (LD-FBP), 9.3% (ULD-FBP), 69.4% (ULD-AIDR 3D), and 77.8% (ULD-FIRST). Statistical analysis showed that the sensitivities of ULD-AIDR 3D and ULD-FIRST were significantly higher than that of ULD-FBP (P < .001). The performance of CAD software in ULD-CT was improved by using IR algorithms. In particular, the performance of CAD in ULD-FIRST was almost equivalent to that in LD-FBP. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Desktop software to identify patients eligible for recruitment into a clinical trial: using SARMA to recruit to the ROAD feasibility trial.

    PubMed

    Treweek, Shaun; Pearson, Ewan; Smith, Natalie; Neville, Ron; Sargeant, Paul; Boswell, Brian; Sullivan, Frank

    2010-01-01

    Recruitment to trials in primary care is often difficult, particularly when practice staff need to identify study participants with acute conditions during consultations. The Scottish Acute Recruitment Management Application (SARMA) system is linked to general practice electronic medical record (EMR) systems and is designed to provide recruitment support to multi-centre trials by screening patients against trial inclusion criteria and alerting practice staff if the patient appears eligible. For patients willing to learn more about the trial, the software allows practice staff to send the patient's contact details to the research team by text message. To evaluate the ability of the software to support trial recruitment. Software evaluation embedded in a randomised controlled trial. Five general practices in Tayside and Fife, Scotland. SARMA was used to support recruitment to a feasibility trial (the Response to Oral Agents in Diabetes, or ROAD trial) looking at users of oral therapy in diabetes. The technical performance of the software and its utility as a recruitment tool were evaluated. The software was successfully installed at four of the five general practices and recruited 11 of the 29 participants for ROAD (other methods were letter and direct invitation by a practice nurse) and had a recruitment return of 35% (11 of 31 texts sent led to a recruitment). Screen failures were relatively low (7 of 31 referred). Practice staff members were positive about the system. An automated recruitment tool can support primary care trials in Scotland and has the potential to support recruitment in other jurisdictions. It offers a low-cost supplement to other trial recruitment methods and is likely to have a much lower screen failure rate than blanket approaches such as mailshots and newspaper campaigns.

  13. Virtual Environment TBI Screen (VETS)

    DTIC Science & Technology

    2014-10-01

    balance challenges performed on a modified Wii Balance Board . Implementation of this device will enhance current approaches in TBI and mild TBI (i.e...TBI) screen (VETS) device in measuring standing balance . This system consists of software, a Wii balance board , and a large screen television that...Validate Wii ™ Balance Board relative to NeuroCom forceplate ! Running Wii Balance Board validation protocol. ! Milestone Achieved:

  14. Large Scale Screening of Low Cost Ferritic Steel Designs For Advanced Ultra Supercritical Boiler Using First Principles Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, Lizhi

    Advanced Ultra Supercritical Boiler (AUSC) requires materials that can operate in corrosive environment at temperature and pressure as high as 760°C (or 1400°F) and 5000psi, respectively, while at the same time maintain good ductility at low temperature. We develop automated simulation software tools to enable fast large scale screening studies of candidate designs. While direct evaluation of creep rupture strength and ductility are currently not feasible, properties such as energy, elastic constants, surface energy, interface energy, and stack fault energy can be used to assess their relative ductility and creeping strength. We implemented software to automate the complex calculations tomore » minimize human inputs in the tedious screening studies which involve model structures generation, settings for first principles calculations, results analysis and reporting. The software developed in the project and library of computed mechanical properties of phases found in ferritic steels, many are complex solid solutions estimated for the first time, will certainly help the development of low cost ferritic steel for AUSC.« less

  15. From Classroom to Computer Screen: NWLP Software. A Set of Computerized Garment-Related Bilingual (English and Chinese) Literacy Lessons.

    ERIC Educational Resources Information Center

    Whu, Lin Fai; Zhang, Ai Ling

    This document describes how National Workplace Literacy Program (NWLP) software was developed for Chinese garment workers in New York City. First, it discusses the goal of the workplace literacy program and the nature of the population served. Then, it indicates how NWLP software was designed to supplement the NWLP curriculum and to reinforce the…

  16. MSiReader: an open-source interface to view and analyze high resolving power MS imaging files on Matlab platform.

    PubMed

    Robichaud, Guillaume; Garrard, Kenneth P; Barry, Jeremy A; Muddiman, David C

    2013-05-01

    During the past decade, the field of mass spectrometry imaging (MSI) has greatly evolved, to a point where it has now been fully integrated by most vendors as an optional or dedicated platform that can be purchased with their instruments. However, the technology is not mature and multiple research groups in both academia and industry are still very actively studying the fundamentals of imaging techniques, adapting the technology to new ionization sources, and developing new applications. As a result, there important varieties of data file formats used to store mass spectrometry imaging data and, concurrent to the development of MSi, collaborative efforts have been undertaken to introduce common imaging data file formats. However, few free software packages to read and analyze files of these different formats are readily available. We introduce here MSiReader, a free open source application to read and analyze high resolution MSI data from the most common MSi data formats. The application is built on the Matlab platform (Mathworks, Natick, MA, USA) and includes a large selection of data analysis tools and features. People who are unfamiliar with the Matlab language will have little difficult navigating the user-friendly interface, and users with Matlab programming experience can adapt and customize MSiReader for their own needs.

  17. Blood-threshold CMR volume analysis of functional univentricular heart.

    PubMed

    Secchi, Francesco; Alì, Marco; Petrini, Marcello; Pluchinotta, Francesca Romana; Cozzi, Andrea; Carminati, Mario; Sardanelli, Francesco

    2018-05-01

    To validate a blood-threshold (BT) segmentation software for cardiac magnetic resonance (CMR) cine images in patients with functional univentricular heart (FUH). We evaluated retrospectively 44 FUH patients aged 25 ± 8 years (mean ± standard deviation). For each patient, the epicardial contour of the single ventricle was manually segmented on cine images by two readers and an automated BT algorithm was independently applied to calculate end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and cardiac mass (CM). Aortic flow analysis (AFA) was performed on through-plane images to obtain forward volumes and used as a benchmark. Reproducibility was tested in a subgroup of 24 randomly selected patients. Wilcoxon, Spearman, and Bland-Altman statistics were used. No significant difference was found between SV (median 57.7 ml; interquartile range 47.9-75.6) and aortic forward flow (57.4 ml; 48.9-80.4) (p = 0.123), with a high correlation (r = 0.789, p < 0.001). Intra-reader reproducibility was 86% for SV segmentation, and 96% for AFA. Inter-reader reproducibility was 85 and 96%, respectively. The BT segmentation provided an accurate and reproducible assessment of heart function in FUH patients.

  18. MSiReader: An Open-Source Interface to View and Analyze High Resolving Power MS Imaging Files on Matlab Platform

    NASA Astrophysics Data System (ADS)

    Robichaud, Guillaume; Garrard, Kenneth P.; Barry, Jeremy A.; Muddiman, David C.

    2013-05-01

    During the past decade, the field of mass spectrometry imaging (MSI) has greatly evolved, to a point where it has now been fully integrated by most vendors as an optional or dedicated platform that can be purchased with their instruments. However, the technology is not mature and multiple research groups in both academia and industry are still very actively studying the fundamentals of imaging techniques, adapting the technology to new ionization sources, and developing new applications. As a result, there important varieties of data file formats used to store mass spectrometry imaging data and, concurrent to the development of MSi, collaborative efforts have been undertaken to introduce common imaging data file formats. However, few free software packages to read and analyze files of these different formats are readily available. We introduce here MSiReader, a free open source application to read and analyze high resolution MSI data from the most common MSi data formats. The application is built on the Matlab platform (Mathworks, Natick, MA, USA) and includes a large selection of data analysis tools and features. People who are unfamiliar with the Matlab language will have little difficult navigating the user-friendly interface, and users with Matlab programming experience can adapt and customize MSiReader for their own needs.

  19. Retina Image Screening and Analysis Software Version 2.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tobin, Jr., Kenneth W.; Karnowski, Thomas P.; Aykac, Deniz

    2009-04-01

    The software allows physicians or researchers to ground-truth images of retinas, identifying key physiological features and lesions that are indicative of disease. The software features methods to automatically detect the physiological features and lesions. The software contains code to measure the quality of images received from a telemedicine network; create and populate a database for a telemedicine network; review and report the diagnosis of a set of images; and also contains components to transmit images from a Zeiss camera to the network through SFTP.

  20. Web Extensible Display Manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slominski, Ryan; Larrieu, Theodore L.

    Jefferson Lab's Web Extensible Display Manager (WEDM) allows staff to access EDM control system screens from a web browser in remote offices and from mobile devices. Native browser technologies are leveraged to avoid installing and managing software on remote clients such as browser plugins, tunnel applications, or an EDM environment. Since standard network ports are used firewall exceptions are minimized. To avoid security concerns from remote users modifying a control system, WEDM exposes read-only access and basic web authentication can be used to further restrict access. Updates of monitored EPICS channels are delivered via a Web Socket using a webmore » gateway. The software translates EDM description files (denoted with the edl suffix) to HTML with Scalable Vector Graphics (SVG) following the EDM's edl file vector drawing rules to create faithful screen renderings. The WEDM server parses edl files and creates the HTML equivalent in real-time allowing existing screens to work without modification. Alternatively, the familiar drag and drop EDM screen creation tool can be used to create optimized screens sized specifically for smart phones and then rendered by WEDM.« less

  1. Receiver-operating-characteristic analysis of an automated program for analyzing striatal uptake of 123I-ioflupane SPECT images: calibration using visual reads.

    PubMed

    Kuo, Phillip Hsin; Avery, Ryan; Krupinski, Elizabeth; Lei, Hong; Bauer, Adam; Sherman, Scott; McMillan, Natalie; Seibyl, John; Zubal, George

    2013-03-01

    A fully automated objective striatal analysis (OSA) program that quantitates dopamine transporter uptake in subjects with suspected Parkinson's disease was applied to images from clinical (123)I-ioflupane studies. The striatal binding ratios or alternatively the specific binding ratio (SBR) of the lowest putamen uptake was computed, and receiver-operating-characteristic (ROC) analysis was applied to 94 subjects to determine the best discriminator using this quantitative method. Ninety-four (123)I-ioflupane SPECT scans were analyzed from patients referred to our clinical imaging department and were reconstructed using the manufacturer-supplied reconstruction and filtering parameters for the radiotracer. Three trained readers conducted independent visual interpretations and reported each case as either normal or showing dopaminergic deficit (abnormal). The same images were analyzed using the OSA software, which locates the striatal and occipital structures and places regions of interest on the caudate and putamen. Additionally, the OSA places a region of interest on the occipital region that is used to calculate the background-subtracted SBR. The lower SBR of the 2 putamen regions was taken as the quantitative report. The 33 normal (bilateral comma-shaped striata) and 61 abnormal (unilateral or bilateral dopaminergic deficit) studies were analyzed to generate ROC curves. Twenty-nine of the scans were interpreted as normal and 59 as abnormal by all 3 readers. For 12 scans, the 3 readers did not unanimously agree in their interpretations (discordant). The ROC analysis, which used the visual-majority-consensus interpretation from the readers as the gold standard, yielded an area under the curve of 0.958 when using 1.08 as the threshold SBR for the lowest putamen. The sensitivity and specificity of the automated quantitative analysis were 95% and 89%, respectively. The OSA program delivers SBR quantitative values that have a high sensitivity and specificity, compared with visual interpretations by trained nuclear medicine readers. Such a program could be a helpful aid for readers not yet experienced with (123)I-ioflupane SPECT images and if further adapted and validated may be useful to assess disease progression during pharmaceutical testing of therapies.

  2. Toolkit of Available EPA Green Infrastructure Modeling Software: Watershed Management Optimization Support Tool (WMOST)

    EPA Science Inventory

    Watershed Management Optimization Support Tool (WMOST) is a software application designed tofacilitate integrated water resources management across wet and dry climate regions. It allows waterresources managers and planners to screen a wide range of practices across their watersh...

  3. Chapter 3: Tabular Data and Graphical Images in Support of the U.S. Geological Survey National Oil and Gas Assessment - Western Gulf Province, Smackover-Austin-Eagle Ford Composite Total Petroleum System (504702)

    USGS Publications Warehouse

    Klett, T.R.; Le, P.A.

    2006-01-01

    This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).

  4. Analyzing clinical phonological data using Phon

    PubMed Central

    McAllister Byun, Tara

    2016-01-01

    In this paper, we describe how Phon, a software program for the transcription and analysis of phonological data, can be applied to facilitate clinical phonological analyses. We begin with a summary of the types of analyses that are frequently used in the assessment and management of speech sound disorders. We then discuss challenges inherent to the transcription and analysis of clinical phonological data. For each challenge, we discuss solutions currently available within Phon, and offer an outlook on future methodological and technical developments in the area of clinical phonology. This paper includes a step-by-step introduction to Phon suitable for readers who lack previous experience with the software. We conclude with a discussion of data sharing and its vital role in advancing research and intervention practices in the area of speech development and disorders. PMID:27111269

  5. CellProfiler and KNIME: open source tools for high content screening.

    PubMed

    Stöter, Martin; Niederlein, Antje; Barsacchi, Rico; Meyenhofer, Felix; Brandl, Holger; Bickle, Marc

    2013-01-01

    High content screening (HCS) has established itself in the world of the pharmaceutical industry as an essential tool for drug discovery and drug development. HCS is currently starting to enter the academic world and might become a widely used technology. Given the diversity of problems tackled in academic research, HCS could experience some profound changes in the future, mainly with more imaging modalities and smart microscopes being developed. One of the limitations in the establishment of HCS in academia is flexibility and cost. Flexibility is important to be able to adapt the HCS setup to accommodate the multiple different assays typical of academia. Many cost factors cannot be avoided, but the costs of the software packages necessary to analyze large datasets can be reduced by using Open Source software. We present and discuss the Open Source software CellProfiler for image analysis and KNIME for data analysis and data mining that provide software solutions which increase flexibility and keep costs low.

  6. Development of Drugs for Epstein - Barr virus using High-Throughput in silico Virtual Screening

    PubMed Central

    Li, Ning; Thompson, Scott; Jiang, Hualiang; Lieberman, Paul M.; Luo, Cheng

    2010-01-01

    Importance of the field Epstein-Barr virus (EBV) is a ubiquitious human herpesvirus that is causally associated with endemic forms of Burkitt’s lymphoma (BL), nasopharyngeal carcinoma, and lymphoproliferative disease in immunosuppressed individuals. On a global scale, EBV infects over 90% of the adult population and is responsible for ~1% of all human cancers. To date, there is no efficacious drug or therapy for the treatment of EBV infection and EBV-related diseases. Areas covered in this review In this review, we discuss the existing anti-EBV inhibitors and those under development. We discuss the value of different molecular targets, including EBV lytic DNA replication enzymes, as well as proteins that are expressed exclusively during latent infection, like EBNA1 and LMP1. Since the atomic structure of the EBNA1 DNA binding domain has been described, it is an attractive target for in silico methods of drug design and small molecule screening. We discuss the use of computational methods that can greatly facilitate the development of novel inhibitors and how in silico screening methods can be applied to target proteins with known structures, like EBNA1, to treat EBV infection and disease. What the reader will gain The reader will be familiarized with the problems in targeting of EBV for inhibition by small molecules and how computational methods can greatly facilitate this process. Take home message Despite the impressive efficacy of nucleoside analogues for the treatment of herpesvirus lytic infection, there remain few effective treatments for latent infections. Since EBV-latent infection persists within and contributes to the formation of EBV-associated cancers, targeting EBV latent proteins is an unmet medical need. High throughput in silico screening can accelerate the process of drug discovery for novel and selective agents that inhibit EBV latent infection and associated disease. PMID:22822721

  7. Chapter 17: Bioimage Informatics for Systems Pharmacology

    PubMed Central

    Li, Fuhai; Yin, Zheng; Jin, Guangxu; Zhao, Hong; Wong, Stephen T. C.

    2013-01-01

    Recent advances in automated high-resolution fluorescence microscopy and robotic handling have made the systematic and cost effective study of diverse morphological changes within a large population of cells possible under a variety of perturbations, e.g., drugs, compounds, metal catalysts, RNA interference (RNAi). Cell population-based studies deviate from conventional microscopy studies on a few cells, and could provide stronger statistical power for drawing experimental observations and conclusions. However, it is challenging to manually extract and quantify phenotypic changes from the large amounts of complex image data generated. Thus, bioimage informatics approaches are needed to rapidly and objectively quantify and analyze the image data. This paper provides an overview of the bioimage informatics challenges and approaches in image-based studies for drug and target discovery. The concepts and capabilities of image-based screening are first illustrated by a few practical examples investigating different kinds of phenotypic changes caEditorsused by drugs, compounds, or RNAi. The bioimage analysis approaches, including object detection, segmentation, and tracking, are then described. Subsequently, the quantitative features, phenotype identification, and multidimensional profile analysis for profiling the effects of drugs and targets are summarized. Moreover, a number of publicly available software packages for bioimage informatics are listed for further reference. It is expected that this review will help readers, including those without bioimage informatics expertise, understand the capabilities, approaches, and tools of bioimage informatics and apply them to advance their own studies. PMID:23633943

  8. Assessment of the Potential for Color Overlays to Enhance the Reading Skills of Enlisted Navy Recruits

    DTIC Science & Technology

    2006-07-30

    as an intervention . Readers with MIS symptoms read significantly faster with their chosen overlay than without it. These findings justify further...recent years, the techniques for routine diagnosis and effective intervention methods for MIS have been improved and developed. Although Irlen is...The British Royal Navy, for example, screens for MIS on a case-by-case basis and provides overlays and filters as intervention . Furthermore

  9. A Proven Method for Meeting Export Control Objectives in Postal and Shipping Sectors

    DTIC Science & Technology

    2015-02-01

    Mellon University for the operation of the Software Engineering Institute, a federally funded research and development center sponsored by the United...Export Control at USPS 5 3.3 Objectives for Improving Export Screening at USPS 6 4 Development of the New Screening Process 7 4.1 “Walking the Model...Export Screening Development Process 10 Figure 2: Induction and Processing of International Mail 10 Figure 3: The Export Screening Process 11

  10. P1198: software for tracing decision behavior in lending to small businesses.

    PubMed

    Andersson, P

    2001-05-01

    This paper describes a process-tracing software program specially designed to capture decision behavior in lending to small businesses. The source code was written in Lotus Notes. The software runs in a Web browser and consists of two interacting systems: a database and a user interface. The database includes three realistic loan applications. The user interface consists of different but interacting screens that enable the participant to operate the software. Log files register the decision behavior of the participant. An empirical example is presented in order to show the software's potential in providing insights into judgment and decision making. The implications of the software are discussed.

  11. A freely available real-time operating system well suited for astronomy and the physical sciences

    NASA Astrophysics Data System (ADS)

    Pedretti, Ettore; Monnier, John D.; Thureau, Nathalie D.; Berger, David H.

    2006-06-01

    This paper wants to be a practical example in building a real-time data-acquisition and control system from scratch using relatively non-expensive PC hardware and open-source software. The practical example of building the control system for the Michigan Infrared Combiner (MIRC) at the CHARA interferometer will be used to give the reader a 'hands-on' experience in installing and configuring the RTAI-Fusion real-time operating system and developing a complete control system with it.

  12. LAMP2GO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Priye, Aashish

    2017-06-08

    The app is a unique image analysis software and acts as a fluorescence reader for multiplexed nucleic acid amplification reactions. If the reaction is positive, a bright fluorescent signal is emitted from the solution depending on the choice of fluorophore molecule. The app reads the Red, blue and green (RGB) channels of the emitted signal and transforms it to yield the chromaticity (x and y) and luminance of the signal. This new representation of signal is far superior to the RGB system in determining the signal color and intensity.

  13. A generic interface element for COMET-AR

    NASA Technical Reports Server (NTRS)

    Mccleary, Susan L.; Aminpour, Mohammad A.

    1995-01-01

    The implementation of an interface element capability within the COMET-AR software system is described. The report is intended for use by both users of currently implemented interface elements and developers of new interface element formulations. Guidance on the use of COMET-AR is given. A glossary is provided as an Appendix to this report for readers unfamiliar with the jargon of COMET-AR. A summary of the currently implemented interface element formulation is presented in Section 7.3 of this report.

  14. Creating a VAPEPS database: A VAPEPS tutorial

    NASA Technical Reports Server (NTRS)

    Graves, George

    1989-01-01

    A procedural method is outlined for creating a Vibroacoustic Payload Environment Prediction System (VAPEPS) Database. The method of presentation employs flowcharts of sequential VAPEPS Commands used to create a VAPEPS Database. The commands are accompanied by explanatory text to the right of the command in order to minimize the need for repetitive reference to the VAPEPS user's manual. The method is demonstrated by examples of varying complexity. It is assumed that the reader has acquired a basic knowledge of the VAPEPS software program.

  15. Development and Application of a High Throughput Protein Unfolding Kinetic Assay

    PubMed Central

    Wang, Qiang; Waterhouse, Nicklas; Feyijinmi, Olusegun; Dominguez, Matthew J.; Martinez, Lisa M.; Sharp, Zoey; Service, Rachel; Bothe, Jameson R.; Stollar, Elliott J.

    2016-01-01

    The kinetics of folding and unfolding underlie protein stability and quantification of these rates provides important insights into the folding process. Here, we present a simple high throughput protein unfolding kinetic assay using a plate reader that is applicable to the studies of the majority of 2-state folding proteins. We validate the assay by measuring kinetic unfolding data for the SH3 (Src Homology 3) domain from Actin Binding Protein 1 (AbpSH3) and its stabilized mutants. The results of our approach are in excellent agreement with published values. We further combine our kinetic assay with a plate reader equilibrium assay, to obtain indirect estimates of folding rates and use these approaches to characterize an AbpSH3-peptide hybrid. Our high throughput protein unfolding kinetic assays allow accurate screening of libraries of mutants by providing both kinetic and equilibrium measurements and provide a means for in-depth ϕ-value analyses. PMID:26745729

  16. Using a Geographic Information System to Improve Childhood Lead-Screening Efforts

    PubMed Central

    2013-01-01

    The Idaho Division of Public Health conducted a pilot study to produce a lead-exposure–risk map to help local and state agencies better target childhood lead-screening efforts. Priority lead-screening areas, at the block group level, were created by using county tax assessor data and geographic information system software. A series of maps were produced, indicating childhood lead-screening prevalence in areas in which there was high potential for exposure to lead. These maps could enable development of more systematically targeted and cost-effective childhood lead-screening efforts. PMID:23764346

  17. Laboratory Connections: Review of Two Commercial Interfacing Packages.

    ERIC Educational Resources Information Center

    Powers, Michael H.

    1989-01-01

    Evaluates two Apple II interfacing packages designed to measure pH: (1) "Experiments in Chemistry" by HRM Software and (2) "Voltage Plotter III" by Vernier Software. Provides characteristics and screen dumps of each package. Reports both systems are suitable for high school or beginning college laboratories. (MVL)

  18. Electronic p-Chip-Based System for Identification of Glass Slides and Tissue Cassettes in Histopathology Laboratories.

    PubMed

    Mandecki, Wlodek; Qian, Jay; Gedzberg, Katie; Gruda, Maryanne; Rodriguez, Efrain Frank; Nesbitt, Leslie; Riben, Michael

    2018-01-01

    The tagging system is based on a small, electronic, wireless, laser-light-activated microtransponder named "p-Chip." The p-Chip is a silicon integrated circuit, the size of which is 600 μm × 600 μm × 100 μm. Each p-Chip contains a unique identification code stored within its electronic memory that can be retrieved with a custom reader. These features allow the p-Chip to be used as an unobtrusive and scarcely noticeable ID tag on glass slides and tissue cassettes. The system is comprised of p-Chip-tagged sample carriers, a dedicated benchtop p-Chip ID reader that can accommodate both objects, and an additional reader (the Wand), with an adapter for reading IDs of glass slides stored vertically in drawers. On slides, p-Chips are attached with adhesive to the center of the short edge, and on cassettes - embedded directly into the plastic. ID readout is performed by bringing the reader to the proximity of the chip. Standard histopathology laboratory protocols were used for testing. Very good ID reading efficiency was observed for both glass slides and cassettes. When processed slides are stored in vertical filing drawers, p-Chips remain readable without the need to remove them from the storage location, thereby improving the speed of searches in collections. On the cassettes, the ID continues to be readable through a thin layer of paraffin. Both slides and tissue cassettes can be read with the same reader, reducing the need for redundant equipment. The p-Chip is stable to all chemical challenges commonly used in the histopathology laboratory, tolerates temperature extremes, and remains durable in long-term storage. The technology is compatible with laboratory information management systems software systems. The p-Chip system is very well suited for identification of glass slides and cassettes in the histopathology laboratory.

  19. Electronic p-Chip-Based System for Identification of Glass Slides and Tissue Cassettes in Histopathology Laboratories

    PubMed Central

    Mandecki, Wlodek; Qian, Jay; Gedzberg, Katie; Gruda, Maryanne; Rodriguez, Efrain “Frank”; Nesbitt, Leslie; Riben, Michael

    2018-01-01

    Background: The tagging system is based on a small, electronic, wireless, laser-light-activated microtransponder named “p-Chip.” The p-Chip is a silicon integrated circuit, the size of which is 600 μm × 600 μm × 100 μm. Each p-Chip contains a unique identification code stored within its electronic memory that can be retrieved with a custom reader. These features allow the p-Chip to be used as an unobtrusive and scarcely noticeable ID tag on glass slides and tissue cassettes. Methods: The system is comprised of p-Chip-tagged sample carriers, a dedicated benchtop p-Chip ID reader that can accommodate both objects, and an additional reader (the Wand), with an adapter for reading IDs of glass slides stored vertically in drawers. On slides, p-Chips are attached with adhesive to the center of the short edge, and on cassettes – embedded directly into the plastic. ID readout is performed by bringing the reader to the proximity of the chip. Standard histopathology laboratory protocols were used for testing. Results: Very good ID reading efficiency was observed for both glass slides and cassettes. When processed slides are stored in vertical filing drawers, p-Chips remain readable without the need to remove them from the storage location, thereby improving the speed of searches in collections. On the cassettes, the ID continues to be readable through a thin layer of paraffin. Both slides and tissue cassettes can be read with the same reader, reducing the need for redundant equipment. Conclusions: The p-Chip is stable to all chemical challenges commonly used in the histopathology laboratory, tolerates temperature extremes, and remains durable in long-term storage. The technology is compatible with laboratory information management systems software systems. The p-Chip system is very well suited for identification of glass slides and cassettes in the histopathology laboratory. PMID:29692946

  20. Prototyping with Data Dictionaries for Requirements Analysis.

    DTIC Science & Technology

    1985-03-01

    statistical packages and software for screen layout. These items work at a higher level than another category of prototyping tool, program generators... Program generators are software packages which, when given specifications, produce source listings, usually in a high order language such as COBCL...with users and this will not happen if he must stop to develcp a detailed program . [Ref. 241] Hardware as well as software should be considered in

  1. Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

    PubMed

    Funaki, Ayumu; Ohkubo, Masaki; Wada, Shinichi; Murao, Kohei; Matsumoto, Toru; Niizuma, Shinji

    2012-07-01

    With the wide dissemination of computed tomography (CT) screening for lung cancer, measuring the nodule volume accurately with computer-aided volumetry software is increasingly important. Many studies for determining the accuracy of volumetry software have been performed using a phantom with artificial nodules. These phantom studies are limited, however, in their ability to reproduce the nodules both accurately and in the variety of sizes and densities required. Therefore, we propose a new approach of using computer-simulated nodules based on the point spread function measured in a CT system. The validity of the proposed method was confirmed by the excellent agreement obtained between computer-simulated nodules and phantom nodules regarding the volume measurements. A practical clinical evaluation of the accuracy of volumetry software was achieved by adding simulated nodules onto clinical lung images, including noise and artifacts. The tested volumetry software was revealed to be accurate within an error of 20 % for nodules >5 mm and with the difference between nodule density and background (lung) (CT value) being 400-600 HU. Such a detailed analysis can provide clinically useful information on the use of volumetry software in CT screening for lung cancer. We concluded that the proposed method is effective for evaluating the performance of computer-aided volumetry software.

  2. Analyzing gene perturbation screens with nested effects models in R and bioconductor.

    PubMed

    Fröhlich, Holger; Beissbarth, Tim; Tresch, Achim; Kostka, Dennis; Jacob, Juby; Spang, Rainer; Markowetz, F

    2008-11-01

    Nested effects models (NEMs) are a class of probabilistic models introduced to analyze the effects of gene perturbation screens visible in high-dimensional phenotypes like microarrays or cell morphology. NEMs reverse engineer upstream/downstream relations of cellular signaling cascades. NEMs take as input a set of candidate pathway genes and phenotypic profiles of perturbing these genes. NEMs return a pathway structure explaining the observed perturbation effects. Here, we describe the package nem, an open-source software to efficiently infer NEMs from data. Our software implements several search algorithms for model fitting and is applicable to a wide range of different data types and representations. The methods we present summarize the current state-of-the-art in NEMs. Our software is written in the R language and freely avail-able via the Bioconductor project at http://www.bioconductor.org.

  3. Characteristics of the group of radiologists that benefits the most using Breast Screen Reader Assessment Strategy (BREAST)

    NASA Astrophysics Data System (ADS)

    Ganesan, A.; Alakhras, M.; Brennan, P. C.; Lee, W.; Tapia, K.; Mello-Thoms, C.

    2018-03-01

    Purpose: To determine the impact of Breast Screen Reader Assessment Strategy (BREAST) over time in improving radiologists' breast cancer detection performance, and to identify the group of radiologists that benefit the most by using BREAST as a training tool. Materials and Methods: Thirty-six radiologists who completed three case-sets offered by BREAST were included in this study. The case-sets were arranged in radiologists' chronological order of completion and five performance measures (sensitivity, specificity, location sensitivity, receiver operating characteristics area under the curve (ROC AUC) and jackknife alternative free-response receiver operating characteristic (JAFROC) figure-of-merit (FOM)), available from BREAST, were compared between case-sets to determine the level of improvement achieved. The radiologists were then grouped based on their characteristics and the above performance measures between the case-sets were compared. Paired t-tests or Wilcoxon signed-rank tests with statistical significance set at p < 0.05 were used to compare the performance measures. Results: Significant improvement was demonstrated in radiologists' case-set performance in terms of location sensitivity and JAFROC FOM over the years, and radiologists' location sensitivity and JAFROC FOM showed significant improvement irrespective of their characteristics. In terms of ROC AUC, significant improvement was shown for radiologists who were reading screen mammograms for more than 7 years and spent more than 9 hours per week reading mammograms. Conclusion: Engaging with case-sets appears to enhance radiologists' performance suggesting the important value of initiatives such as BREAST. However, such performance enhancement was not shown for everyone, highlighting the need to tailor the BREAST platform to benefit all radiologists.

  4. MoKey: A versatile exergame creator for everyday usage.

    PubMed

    Eckert, Martina; López, Marcos; Lázaro, Carlos; Meneses, Juan

    2017-11-27

    Currently, virtual applications for physical exercises are highly appreciated as rehabilitation instruments. This article presents a middleware called "MoKey" (Motion Keyboard), which converts standard off-the-shelf software into exergames (exercise games). A configurable set of gestures, captured by a motion capture camera, is translated into the key strokes required by the chosen software. The present study assesses the tool regarding usability and viability on a heterogeneous group of 11 participants, aged 5 to 51, with moderate to severe disabilities, and mostly bound to a wheelchair. In comparison with FAAST (The Flexible Action and Articulated Skeleton Toolkit), MoKey achieved better results in terms of ease of use and computational load. The viability as an exergame creator tool was proven with help of four applications (PowerPoint®, e-book reader, Skype®, and Tetris). Success rates of up to 91% have been achieved, subjective perception was rated with 4.5 points (from 0-5). The middleware provides increased motivation due to the use of favorite software and the advantage of exploiting it for exercise. Used together with communication software or online games, social inclusion can be stimulated. The therapists can employ the tool to monitor the correctness and progress of the exercises.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klise, Katherine A.; Murray, Regan; Bynum, Michael

    Water utilities are vulnerable to a wide variety of human-caused and natural disasters. These disruptive events can result in loss of water service, contaminated water, pipe breaks, and failed equipment. Furthermore, long term changes in water supply and customer demand can have a large impact on the operating conditions of the network. The ability to maintain drinking water service during and following these types of events is critical. Simulation and analysis tools can help water utilities explore how their network will respond to disruptive events and plan effective mitigation strategies. The U.S. Environmental Protection Agency and Sandia National Laboratories aremore » developing new software tools to meet this need. The Water Network Tool for Resilience (WNTR, pronounced winter) is a Python package designed to help water utilities investigate resilience of water distribution systems over a wide range of hazardous scenarios and to evaluate resilience-enhancing actions. The following documentation includes installation instructions and examples, description of software features, and software license. It is assumed that the reader is familiar with the Python Programming Language. References are included for additional background on software components. Online documentation, hosted at http://wntr.readthedocsio/, will be updated as new features are added. The online version includes API documentation and information for developers.« less

  6. Sensor Placement Optimization using Chama

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klise, Katherine A.; Nicholson, Bethany L.; Laird, Carl Damon

    Continuous or regularly scheduled monitoring has the potential to quickly identify changes in the environment. However, even with low - cost sensors, only a limited number of sensors can be deployed. The physical placement of these sensors, along with the sensor technology and operating conditions, can have a large impact on the performance of a monitoring strategy. Chama is an open source Python package which includes mixed - integer, stochastic programming formulations to determine sensor locations and technology that maximize monitoring effectiveness. The methods in Chama are general and can be applied to a wide range of applications. Chama ismore » currently being used to design sensor networks to monitor airborne pollutants and to monitor water quality in water distribution systems. The following documentation includes installation instructions and examples, description of software features, and software license. The software is intended to be used by regulatory agencies, industry, and the research community. It is assumed that the reader is familiar with the Python Programming Language. References are included for addit ional background on software components. Online documentation, hosted at http://chama.readthedocs.io/, will be updated as new features are added. The online version includes API documentation .« less

  7. An optical authentication system based on imaging of excitation-selected lanthanide luminescence.

    PubMed

    Carro-Temboury, Miguel R; Arppe, Riikka; Vosch, Tom; Sørensen, Thomas Just

    2018-01-01

    Secure data encryption relies heavily on one-way functions, and copy protection relies on features that are difficult to reproduce. We present an optical authentication system based on lanthanide luminescence from physical one-way functions or physical unclonable functions (PUFs). They cannot be reproduced and thus enable unbreakable encryption. Further, PUFs will prevent counterfeiting if tags with unique PUFs are grafted onto products. We have developed an authentication system that comprises a hardware reader, image analysis, and authentication software and physical keys that we demonstrate as an anticounterfeiting system. The physical keys are PUFs made from random patterns of taggants in polymer films on glass that can be imaged following selected excitation of particular lanthanide(III) ions doped into the individual taggants. This form of excitation-selected imaging ensures that by using at least two lanthanide(III) ion dopants, the random patterns cannot be copied, because the excitation selection will fail when using any other emitter. With the developed reader and software, the random patterns are read and digitized, which allows a digital pattern to be stored. This digital pattern or digital key can be used to authenticate the physical key in anticounterfeiting or to encrypt any message. The PUF key was produced with a staggering nominal encoding capacity of 7 3600 . Although the encoding capacity of the realized authentication system reduces to 6 × 10 104 , it is more than sufficient to completely preclude counterfeiting of products.

  8. HAZPAC; an interactive map of Pacific Rim natural hazards, population, and infrastructure

    USGS Publications Warehouse

    Bemis, B.L.; Goss, H.V.; Yurkovich, E.S.; Perron, T.J.; Howell, D.G.

    2002-01-01

    This is an online version of a CD-ROM publication. The text files that describe using this publication make reference to software provided on the disc. For this online version the software can be downloaded for free from Adobe Systems and Environmental Systems Research Institute, Inc. (ESRI). Welcome to HAZPAC! HAZPAC is an interactive map about natural hazard risk in the Pacific Rim region. It is intended to communicate to a broad audience the ideas of 'Crowding the Rim,' which is an international, public-private partnership that fosters collaborative solutions for regional risks. HAZPAC, which stands for 'HAZards of the PACific,' uses Geographic Information System (GIS) technology to help people visualize the socioeconomic connections and shared hazard vulnerabilities among Pacific Rim countries, as well as to explore the general nature of risk. Please refer to the 'INTRODUCTION TO HAZPAC' section of the readme file below to determine which HAZPAC project will be right for you. Once you have decided which HAZPAC project is suitable for you, please refer to the 'GETTING STARTED' sections in the readme file for some basic information that will help you begin using HAZPAC. Also, we highly recommend that you follow the Tutorial exercises in the project-specific HAZPAC User Guides. The User Guides are PDF (Portable Document Format) files that must be read with Adobe Acrobat Reader (a free copy of Acrobat Reader is available using the link near the bottom of this page).

  9. Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology.

    PubMed

    Axelsen, M B; Stoltenberg, M; Poggenborg, R P; Kubassova, O; Boesen, M; Bliddal, H; Hørslev-Petersen, K; Hanson, L G; Østergaard, M

    2012-03-01

    To determine whether dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) evaluated using semi-automatic image processing software can accurately assess synovial inflammation in rheumatoid arthritis (RA) knee joints. In 17 RA patients undergoing knee surgery, the average grade of histological synovial inflammation was determined from four biopsies obtained during surgery. A preoperative series of T(1)-weighted dynamic fast low-angle shot (FLASH) MR images was obtained. Parameters characterizing contrast uptake dynamics, including the initial rate of enhancement (IRE), were generated by the software in three different areas: (I) the entire slice (Whole slice); (II) a manually outlined region of interest (ROI) drawn quickly around the joint, omitting large artefacts such as blood vessels (Quick ROI); and (III) a manually outlined ROI following the synovial capsule of the knee joint (Precise ROI). Intra- and inter-reader agreement was assessed using the intra-class correlation coefficient (ICC). The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho) = 0.70, p = 0.001 and rho = 0.74, p = 0.001, respectively). Intra- and inter-reader ICCs were very high (0.93-1.00). No Whole slice parameters were correlated to histology. DCE-MRI provides fast and accurate assessment of synovial inflammation in RA patients. Manual outlining of the joint to omit large artefacts is necessary.

  10. Reader interactome of epigenetic histone marks in birds.

    PubMed

    Bluhm, Alina; Casas-Vila, Nuria; Scheibe, Marion; Butter, Falk

    2016-02-01

    Lysine methylation is part of the posttranscriptional histone code employed to recruit modification specific readers to chromatin. Unbiased, quantitative mass spectrometry approaches combined with peptide pull-downs have been used to study histone methylation-dependent binders in mammalian cells. Here, we extend the study to birds by investigating the interaction partners for H3K4me3, H3K9me3, H3K27me3 and H3K36me3 in chicken (Gallus gallus) and zebra finch (Taeniopygia guttata) using label-free quantitative proteomics. In general, we find very strong overlap in interaction partners for the trimethyl marks in birds compared to mammals, underscoring the known conserved function of these modifications. In agreement with their epigenetic role, we find binding of PHF2 and members of the TFIID, SAGA, SET1 and NURF complex to the activation mark H3K4me3. Our data furthermore supports the existence of a LID complex in vertebrates recruited to the H3K4me3 mark. The repressive marks are bound by the HP1 proteins and the EED subunit of the PRC2 complex as well as by WIZ. Like reported in the previous mammalian screens, we found ZNF462, ZNF828 and POGZ enriched at H3K9me3. However, we noted some unexpected differences. N-PAC (also known as GLYR1), an H3K36me3 interactor in mammals, is reproducible not enriched at this modification in our screen in birds. This initial finding suggests that despite strong conservation of the histone tail sequence, a few species-specific differences in epigenetic readers may have evolved between birds and mammals. All MS data have been deposited in the ProteomeXchange with identifier PXD002282 (http://proteomecentral.proteomexchange.org/dataset/PXD002282). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Database Access Manager for the Software Engineering Laboratory (DAMSEL) user's guide

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Operating instructions for the Database Access Manager for the Software Engineering Laboratory (DAMSEL) system are presented. Step-by-step instructions for performing various data entry and report generation activities are included. Sample sessions showing the user interface display screens are also included. Instructions for generating reports are accompanied by sample outputs for each of the reports. The document groups the available software functions by the classes of users that may access them.

  12. Information management and information technologies: keys to professional and business success.

    PubMed

    Otten, K W

    1984-01-01

    Personal computers, spreadsheets, decision support software, electronic mail and video disks are just a few of the innovations of information technology which attract the attention of information professionals and managers alike: they are all concerned with the rapidly changing face of information technology and how to cope with a changing competitive environment, personally, and for the benefit of their companies. This paper is the first in a monthly series which tries to illuminate some of the factors and changes which shape our future as professionals and managers. In so doing, it guides and motivates the reader to become "information literate," a prerequisite for personal advancement in an information-based economy. This first paper outlines the relationship between technological innovations, use of information tools and information management and what to consider in order to benefit from the information revolution. It explains the risks of becoming professionally obsolete and alerts the reader to get personally involved to remain or become "information and computer literate."

  13. WRAP low level waste restricted waste management (LLW RWM) glovebox acceptance test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1997-11-24

    On April 22, 1997, the Low Level Waste Restricted Waste Management (LLW RWM) glovebox was tested using acceptance test procedure 13027A-87. Mr. Robert L. Warmenhoven served as test director, Mr. Kendrick Leist acted as test operator and test witness, and Michael Lane provided miscellaneous software support. The primary focus of the glovebox acceptance test was to examine glovebox control system interlocks, operator Interface Unit (OIU) menus, alarms, and messages. Basic drum port and lift table control sequences were demonstrated. OIU menus, messages, and alarm sequences were examined, with few exceptions noted. Barcode testing was bypassed, due to the lack ofmore » installed equipment as well as the switch from basic reliance on fixed bar code readers to the enhanced use of portable bar code readers. Bar code testing was completed during performance of the LLW RWM OTP. Mechanical and control deficiencies were documented as Test Exceptions during performance of this Acceptance Test. These items are attached as Appendix A to this report.« less

  14. A CCD-based reader combined with CdS quantum dot-labeled lateral flow strips for ultrasensitive quantitative detection of CagA

    NASA Astrophysics Data System (ADS)

    Gui, Chen; Wang, Kan; Li, Chao; Dai, Xuan; Cui, Daxiang

    2014-02-01

    Immunochromatographic assays are widely used to detect many analytes. CagA is proved to be associated closely with initiation of gastric carcinoma. Here, we reported that a charge-coupled device (CCD)-based test strip reader combined with CdS quantum dot-labeled lateral flow strips for quantitative detection of CagA was developed, which used 365-nm ultraviolet LED as the excitation light source, and captured the test strip images through an acquisition module. Then, the captured image was transferred to the computer and was processed by a software system. A revised weighted threshold histogram equalization (WTHE) image processing algorithm was applied to analyze the result. CdS quantum dot-labeled lateral flow strips for detection of CagA were prepared. One hundred sera samples from clinical patients with gastric cancer and healthy people were prepared for detection, which demonstrated that the device could realize rapid, stable, and point-of-care detection, with a sensitivity of 20 pg/mL.

  15. Decision-making and cancer screening: a qualitative study of older adults with multiple chronic conditions.

    PubMed

    Gross, Cary P; Fried, Terri R; Tinetti, Mary E; Ross, Joseph S; Genao, Inginia; Hossain, Sabina; Wolf, Elizabeth; Lewis, Carmen L

    2015-03-01

    To understand how older persons with multiple chronic conditions (MCC) approach decisions about cancer screening. We conducted interviews with adults >65 years old with at least two chronic conditions who were taking ≥five medications daily. Patients were first asked how age and multimorbidity influence their cancer screening decisions. After showing them an educational prompt that explained the relationship between life expectancy and the benefits of cancer screening, respondents were then asked about screening in the context of specific health scenarios. Using grounded theory, three independent readers coded responses for salient themes. Sample size was determined by thematic saturation. Most respondents (26 of 28) initially indicated that their overall health or medical conditions do not influence their cancer screening decisions. After viewing the educational prompt, respondents described two broad approaches to cancer screening in the setting of increasing age or multi-morbidity. The first was a "benefits versus harms" approach in which participants weighed direct health benefits (e.g. reducing cancer incidence or mortality) and harms (e.g. complications or inconvenience). The second was a heuristic approach. Some heuristics favored screening, such as a persistent belief in unspecified benefits from screening, value of knowledge about cancer status, and not wanting to "give up", whereas other heuristics discouraged screening, such as fatalism or a reluctance to learn about their cancer status. When considering cancer screening, some older persons with MCC employ heuristics which circumvent the traditional quantitative comparison of risks and benefits, providing an important challenge to informed decision making. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Assertions of Japanese Websites for and Against Cancer Screening: a Text Mining Analysis

    PubMed

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2017-04-01

    Background: Cancer screening rates are lower in Japan than in Western countries such as the United States and the United Kingdom. While health professionals publish pro-cancer-screening messages online to encourage proactive seeking for screening, anti-screening activists use the same medium to warn readers against following guidelines. Contents of pro- and anti-cancer-screening sites may contribute to readers’ acceptance of one or the other position. We aimed to use a text-mining method to examine frequently appearing contents on sites for and against cancer screening. Methods: We conducted online searches in December 2016 using two major search engines in Japan (Google Japan and Yahoo! Japan). Targeted websites were classified as “pro”, “anti”, or “neutral” depending on their claims, with the author(s) classified as “health professional”, “mass media”, or “layperson”. Text-mining analyses were conducted, and statistical analysis was performed using the chi-square test. Results: Of the 169 websites analyzed, the top-three most frequently appearing content topics in pro sites were reducing mortality via cancer screening, benefits of early detection, and recommendations for obtaining detailed examination. The top three most frequent in anti-sites were harm from radiation exposure, non-efficacy of cancer screening, and lack of necessity of early detection. Anti-sites also frequently referred to a well-known Japanese radiologist, Makoto Kondo, who rejects the standard forms of cancer care. Conclusion: Our findings should enable authors of pro-cancer-screening sites to write to counter misleading anti-cancer-screening messages and facilitate dissemination of accurate information. Creative Commons Attribution License

  17. An in vitro AChE inhibition assay combined with UF-HPLC-ESI-Q-TOF/MS approach for screening and characterizing of AChE inhibitors from roots of Coptis chinensis Franch.

    PubMed

    Zhao, Hengqiang; Zhou, Siduo; Zhang, Minmin; Feng, Jinhong; Wang, Shanshan; Wang, Daijie; Geng, Yanling; Wang, Xiao

    2016-02-20

    In this study, an in vitro acetylcholinesterase (AChE) inhibition assay based on microplate reader combined with ultrafiltration high performance liquid chromatography-electrospray quadrupole time of flight mass (UF-HPLC-ESI-Q-TOF/MS) was developed for the rapid screening and identification of acetylcholinesterase inhibitors (AChEI) from roots of Coptis chinensis Franch. Incubation conditions such as enzyme concentration, incubation time, incubation temperature and co-solvent was optimized so as to get better screening results. Five alkaloids including columbamine, jatrorrhizine, coptisine, palmatine and berberine were found with AChE inhibition activity in the 80% ethanol extract of C. chinensis Franch. The screened compounds were identified by HPLC-DAD-ESI-Q-TOF/MS compared with the reference stands and literatures. The screened results were verified by in vitro AChE inhibition assays, palmatine showed the best AChE inhibitory activities with IC50 values of 36.6μM among the five compounds. Results of the present study indicated that the combinative method using in vitro AChE inhibition assay and UF-HPLC-ESI-Q-TOF/MS could be widely applied for rapid screening and identification of AChEI from complex TCM extract. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Postmortem validation of breast density using dual-energy mammography

    PubMed Central

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548

  19. Postmortem validation of breast density using dual-energy mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less

  20. Increasing Navigation Speed at Endoluminal CT Colonography Reduces Colonic Visualization and Polyp Identification.

    PubMed

    Plumb, Andrew A; Phillips, Peter; Spence, Graeme; Mallett, Susan; Taylor, Stuart A; Halligan, Steve; Fanshawe, Thomas

    2017-08-01

    Purpose To investigate the effect of increasing navigation speed on the visual search and decision making during polyp identification for computed tomography (CT) colonography Materials and Methods Institutional review board permission was obtained to use deidentified CT colonography data for this prospective reader study. After obtaining informed consent from the readers, 12 CT colonography fly-through examinations that depicted eight polyps were presented at four different fixed navigation speeds to 23 radiologists. Speeds ranged from 1 cm/sec to 4.5 cm/sec. Gaze position was tracked by using an infrared eye tracker, and readers indicated that they saw a polyp by clicking a mouse. Patterns of searching and decision making by speed were investigated graphically and by multilevel modeling. Results Readers identified polyps correctly in 56 of 77 (72.7%) of viewings at the slowest speed but in only 137 of 225 (60.9%) of viewings at the fastest speed (P = .004). They also identified fewer false-positive features at faster speeds (42 of 115; 36.5%) of videos at slowest speed, 89 of 345 (25.8%) at fastest, P = .02). Gaze location was highly concentrated toward the central quarter of the screen area at faster speeds (mean gaze points at slowest speed vs fastest speed, 86% vs 97%, respectively). Conclusion Faster navigation speed at endoluminal CT colonography led to progressive restriction of visual search patterns. Greater speed also reduced both true-positive and false-positive colorectal polyp identification. © RSNA, 2017 Online supplemental material is available for this article.

  1. Water Distribution System Risk Tool for Investment Planning (WaterRF Report 4332)

    EPA Science Inventory

    Product Description/Abstract The product consists of the Pipe Risk Screening Tool (PRST), and a report on the development and use of the tool. The PRST is a software-based screening aid to identify and rank candidate pipes for actions that range from active monitoring (including...

  2. Touch Screen Tablets and Emergent Literacy

    ERIC Educational Resources Information Center

    Neumann, Michelle M.; Neumann, David L.

    2014-01-01

    The use of touch screen tablets by young children is increasing in the home and in early childhood settings. The simple tactile interface and finger-based operating features of tablets may facilitate preschoolers' use of tablet application software and support their educational development in domains such as literacy. This article reviews…

  3. Empirical Data Collection and Analysis Using Camtasia and Transana

    ERIC Educational Resources Information Center

    Thorsteinsson, Gisli; Page, Tom

    2009-01-01

    One of the possible techniques for collecting empirical data is video recordings of a computer screen with specific screen capture software. This method for collecting empirical data shows how students use the BSCWII (Be Smart Cooperate Worldwide--a web based collaboration/groupware environment) to coordinate their work and collaborate in…

  4. Microplate-based method to screen inhibitors of isozymes of cyclic nucleotide phosphodiesterase fused to SUMO.

    PubMed

    Chen, Chunyan; Liu, Miaomiao; Wu, Jing; Yang, Xiaolan; Hu, Xiaolei; Pu, Jun; Long, Gaobo; Xie, Yanling; Jiang, Hairong; Yuan, Yonghua; Liao, Fei

    2014-12-01

    The feasibility for microplate-based screening of inhibitors of isozymes of cyclic nucleotide phosphodiesterase (PDE) was tested via the coupled action of a phosphatase on adenosine-5'-monophosphate and an improved malachite green assay of phosphate. Human full-length PDE4B2 and truncated mutant (152-528aa) were expressed in Escherichia coli via fusion to SUMO, which after purification through Ni-NTA column exhibited specific activities >0.017 U mg(-1). In the presence of proteins <30 mg L(-1), absorbance for 10 µΜ phosphate was measurable; a PDE isozyme of specific activity over 0.008 U mg(-1) after reaction for 20 min thus suited for microplate-based screening of inhibitors. By using Biotek ELX 800 microplate reader, affinities of two forms of PEDE4B2 for cAMP, rolipram and papaverine varied over three magnitudes and were consistent with those by routine assay, respectively. Hence, the proposed method was promising for high-throughput-screening of inhibitors of phosphate-releasing enzymes bearing specific activities over 0.008 U mg(-1).

  5. Keys to a drug-free workplace

    NASA Astrophysics Data System (ADS)

    Fortuna, Joseph J.; Fortuna, Patricia B.

    1997-01-01

    What does it take to establish a drug free work place. Are technologies available other than urine testing for pre- employment screening and monitoring of employees. Various methods are now available to screen for illicit drug residues on items handled by individuals. The residues can be acquired from the surfaces of items such as telephones, door knobs, steering wheels, lockers, clothing, identification cards, etc. Test kits are also available for urine testing at NIDA threshold levels. Analysis of hair, saliva, and sweat is now possible. How good ar these methods and kits. What value are they to the public. What are the legal concerns facing employers. What do the screening test show. These questions and others are addressed in this paper. The authors review for the reader how drug abuse by US workers costs businesses. The paper then addresses the various aspects of the DOT regulations to determine why urine analysis (UA) is insufficient to eliminate drug abuse. The authors present applications of screening technologies in addition to UA. Finally, the authors provide a conclusion of findings and recommendations for businesses that truly want or need drug free work places.

  6. Fluorescent screens and image processing for the APS linac test stand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, W.; Ko, K.

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image processing will also be discussed.

  7. Prototype Packaged Databases and Software in Health

    PubMed Central

    Gardenier, Turkan K.

    1980-01-01

    This paper describes the recent demand for packaged databases and software for health applications in light of developments in mini-and micro-computer technology. Specific features for defining prospective user groups are discussed; criticisms generated for large-scale epidemiological data use as a means of replacing clinical trials and associated controls are posed to the reader. The available collaborative efforts for access and analysis of jointly structured health data are stressed, with recommendations for new analytical techniques specifically geared to monitoring data such as the CTSS (Cumulative Transitional State Score) generated for tacking ongoing patient status over time in clinical trials. Examples of graphic display are given from the Domestic Information Display System (DIDS) which is a collaborative multi-agency effort to computerize and make accessible user-specified U.S. and local maps relating to health, environment, socio-economic and energy data.

  8. Chapter 6. Tabular data and graphical images in support of the U.S. Geological Survey National Oil and Gas Assessment-East Texas basin and Louisiana-Mississippi salt basins provinces, Jurassic Smackover interior salt basins total petroleum system (504902), Travis Peak and Hosston formations.

    USGS Publications Warehouse

    ,

    2006-01-01

    This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on the CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).

  9. Chapter 3. Tabular data and graphical images in support of the U.S. Geological Survey National Oil and Gas Assessment--East Texas basin and Louisiana-Mississippi salt basins provinces, Jurassic Smackover Interior salt basins total petroleum system (504902), Cotton Valley group.

    USGS Publications Warehouse

    Klett, T.R.; Le, P.A.

    2006-01-01

    This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on the CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).

  10. Freely available compound data sets and software tools for chemoinformatics and computational medicinal chemistry applications

    PubMed Central

    Bajorath, Jurgen

    2012-01-01

    We have generated a number of  compound data sets and programs for different types of applications in pharmaceutical research. These data sets and programs were originally designed for our research projects and are made publicly available. Without consulting original literature sources, it is difficult to understand specific features of data sets and software tools, basic ideas underlying their design, and applicability domains. Currently, 30 different entries are available for download from our website. In this data article, we provide an overview of the data and tools we make available and designate the areas of research for which they should be useful. For selected data sets and methods/programs, detailed descriptions are given. This article should help interested readers to select data and tools for specific computational investigations. PMID:24358818

  11. Labview Interface Concepts Used in NASA Scientific Investigations and Virtual Instruments

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Parker, Bradford H.; Rapchun, David A.; Jones, Hollis H.; Cao, Wei

    2001-01-01

    This article provides an overview of several software control applications developed for NASA using LabVIEW. The applications covered here include (1) an Ultrasonic Measurement System for nondestructive evaluation of advanced structural materials, an Xray Spectral Mapping System for characterizing the quality and uniformity of developing photon detector materials, (2) a Life Testing System for these same materials, (3) and the instrument panel for an aircraft mounted Cloud Absorption Radiometer that measures the light scattered by clouds in multiple spectral bands. Many of the software interface concepts employed are explained. Panel layout and block diagram (code) strategies for each application are described. In particular, some of the more unique features of the applications' interfaces and source code are highlighted. This article assumes that the reader has a beginner-to-intermediate understanding of LabVIEW methods.

  12. Designing Colorectal Cancer Screening Decision Support: A Cognitive Engineering Enterprise.

    PubMed

    Militello, Laura G; Saleem, Jason J; Borders, Morgan R; Sushereba, Christen E; Haverkamp, Donald; Wolf, Steven P; Doebbeling, Bradley N

    2016-03-01

    Adoption of clinical decision support has been limited. Important barriers include an emphasis on algorithmic approaches to decision support that do not align well with clinical work flow and human decision strategies, and the expense and challenge of developing, implementing, and refining decision support features in existing electronic health records (EHRs). We applied decision-centered design to create a modular software application to support physicians in managing and tracking colorectal cancer screening. Using decision-centered design facilitates a thorough understanding of cognitive support requirements from an end user perspective as a foundation for design. In this project, we used an iterative design process, including ethnographic observation and cognitive task analysis, to move from an initial design concept to a working modular software application called the Screening & Surveillance App. The beta version is tailored to work with the Veterans Health Administration's EHR Computerized Patient Record System (CPRS). Primary care providers using the beta version Screening & Surveillance App more accurately answered questions about patients and found relevant information more quickly compared to those using CPRS alone. Primary care providers also reported reduced mental effort and rated the Screening & Surveillance App positively for usability.

  13. Designing Colorectal Cancer Screening Decision Support: A Cognitive Engineering Enterprise

    PubMed Central

    Militello, Laura G.; Saleem, Jason J.; Borders, Morgan R.; Sushereba, Christen E.; Haverkamp, Donald; Wolf, Steven P.; Doebbeling, Bradley N.

    2016-01-01

    Adoption of clinical decision support has been limited. Important barriers include an emphasis on algorithmic approaches to decision support that do not align well with clinical work flow and human decision strategies, and the expense and challenge of developing, implementing, and refining decision support features in existing electronic health records (EHRs). We applied decision-centered design to create a modular software application to support physicians in managing and tracking colorectal cancer screening. Using decision-centered design facilitates a thorough understanding of cognitive support requirements from an end user perspective as a foundation for design. In this project, we used an iterative design process, including ethnographic observation and cognitive task analysis, to move from an initial design concept to a working modular software application called the Screening & Surveillance App. The beta version is tailored to work with the Veterans Health Administration’s EHR Computerized Patient Record System (CPRS). Primary care providers using the beta version Screening & Surveillance App more accurately answered questions about patients and found relevant information more quickly compared to those using CPRS alone. Primary care providers also reported reduced mental effort and rated the Screening & Surveillance App positively for usability. PMID:26973441

  14. Molecular modeling, simulation and virtual screening of MurD ligase protein from Salmonella typhimurium LT2.

    PubMed

    Samal, Himanshu Bhusan; Das, Jugal Kishore; Mahapatra, Rajani Kanta; Suar, Mrutyunjay

    2015-01-01

    The Mur enzymes of the peptidoglycan biosynthesis pathway constitute ideal targets for the design of new classes of antimicrobial inhibitors in Gram-negative bacteria. We built a homology model of MurD of Salmonella typhimurium LT2 using MODELLER (9v12) software. 'The homology model was subjected to energy minimization by molecular dynamics (MD) simulation study with GROMACS software for a simulation time of 20 ns in water environment. The model was subjected for virtual screening study from the Zinc Database using Dockblaster software. Inhibition assay for the best inhibitor, 3-(amino methyl)-n-(4-methoxyphenyl) aniline, by flow cytometric analysis revealed the effective inhibition of peptidoglycan biosynthesis. Results from this study provide new insights for the molecular understanding and development of new antibacterial drugs against the pathogen. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Reader variability in breast density estimation from full-field digital mammograms: the effect of image postprocessing on relative and absolute measures.

    PubMed

    Keller, Brad M; Nathan, Diane L; Gavenonis, Sara C; Chen, Jinbo; Conant, Emily F; Kontos, Despina

    2013-05-01

    Mammographic breast density, a strong risk factor for breast cancer, may be measured as either a relative percentage of dense (ie, radiopaque) breast tissue or as an absolute area from either raw (ie, "for processing") or vendor postprocessed (ie, "for presentation") digital mammograms. Given the increasing interest in the incorporation of mammographic density in breast cancer risk assessment, the purpose of this study is to determine the inherent reader variability in breast density assessment from raw and vendor-processed digital mammograms, because inconsistent estimates could to lead to misclassification of an individual woman's risk for breast cancer. Bilateral, mediolateral-oblique view, raw, and processed digital mammograms of 81 women were retrospectively collected for this study (N = 324 images). Mammographic percent density and absolute dense tissue area estimates for each image were obtained from two radiologists using a validated, interactive software tool. The variability of interreader agreement was not found to be affected by the image presentation style (ie, raw or processed, F-test: P > .5). Interreader estimates of relative and absolute breast density are strongly correlated (Pearson r > 0.84, P < .001) but systematically different (t-test, P < .001) between the two readers. Our results show that mammographic density may be assessed with equal reliability from either raw or vendor postprocessed images. Furthermore, our results suggest that the primary source of density variability comes from the subjectivity of the individual reader in assessing the absolute amount of dense tissue present in the breast, indicating the need to use standardized tools to mitigate this effect. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  16. Observations on online educational materials for powder diffraction crystallography software.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toby, B. H.

    2010-10-01

    This article presents a series of approaches used to educate potential users of crystallographic software for powder diffraction. The approach that has been most successful in the author's opinion is the web lecture, where an audio presentation is coupled to a video-like record of the contents of the presenter's computer screen.

  17. Educational Software Employing Group Competition Using an Interactive Electronic Whiteboard

    ERIC Educational Resources Information Center

    Otsuki, Yoko; Bandoh, Hirokazu; Kato, Naoki; Indurkhya, Bipin; Nakagawa, Masaki

    2004-01-01

    This article presents a design of educational software employing group competition using a large interactive electronic whiteboard, and a report on its experimental use. Group competition and collaboration are useful methods to cultivate originality and communication skills. To share the same space, the same large screen, and face-to-face…

  18. Designing Better Camels: Developing Effective Documentation for Computer Software.

    ERIC Educational Resources Information Center

    Zacher, Candace M.

    This guide to the development of effective documentation for users of computer software begins by identifying five types of documentation, i.e., training manuals, user guides, tutorials, on-screen help comments, and troubleshooting manuals. Six steps in the development process are then outlined and briefly described: (1) planning and preparation;…

  19. Captivate MenuBuilder: Creating an Online Tutorial for Teaching Software

    ERIC Educational Resources Information Center

    Yelinek, Kathryn; Tarnowski, Lynn; Hannon, Patricia; Oliver, Susan

    2008-01-01

    In this article, the authors, students in an instructional technology graduate course, describe a process to create an online tutorial for teaching software. They created the tutorial for a cyber school's use. Five tutorial modules were linked together through one menu screen using the MenuBuilder feature in the Adobe Captivate program. The…

  20. Software Graphical User Interface For Analysis Of Images

    NASA Technical Reports Server (NTRS)

    Leonard, Desiree M.; Nolf, Scott R.; Avis, Elizabeth L.; Stacy, Kathryn

    1992-01-01

    CAMTOOL software provides graphical interface between Sun Microsystems workstation and Eikonix Model 1412 digitizing camera system. Camera scans and digitizes images, halftones, reflectives, transmissives, rigid or flexible flat material, or three-dimensional objects. Users digitize images and select from three destinations: work-station display screen, magnetic-tape drive, or hard disk. Written in C.

  1. Fragment-Based Docking: Development of the CHARMMing Web User Interface as a Platform for Computer-Aided Drug Design

    PubMed Central

    2015-01-01

    Web-based user interfaces to scientific applications are important tools that allow researchers to utilize a broad range of software packages with just an Internet connection and a browser.1 One such interface, CHARMMing (CHARMM interface and graphics), facilitates access to the powerful and widely used molecular software package CHARMM. CHARMMing incorporates tasks such as molecular structure analysis, dynamics, multiscale modeling, and other techniques commonly used by computational life scientists. We have extended CHARMMing’s capabilities to include a fragment-based docking protocol that allows users to perform molecular docking and virtual screening calculations either directly via the CHARMMing Web server or on computing resources using the self-contained job scripts generated via the Web interface. The docking protocol was evaluated by performing a series of “re-dockings” with direct comparison to top commercial docking software. Results of this evaluation showed that CHARMMing’s docking implementation is comparable to many widely used software packages and validates the use of the new CHARMM generalized force field for docking and virtual screening. PMID:25151852

  2. Fragment-based docking: development of the CHARMMing Web user interface as a platform for computer-aided drug design.

    PubMed

    Pevzner, Yuri; Frugier, Emilie; Schalk, Vinushka; Caflisch, Amedeo; Woodcock, H Lee

    2014-09-22

    Web-based user interfaces to scientific applications are important tools that allow researchers to utilize a broad range of software packages with just an Internet connection and a browser. One such interface, CHARMMing (CHARMM interface and graphics), facilitates access to the powerful and widely used molecular software package CHARMM. CHARMMing incorporates tasks such as molecular structure analysis, dynamics, multiscale modeling, and other techniques commonly used by computational life scientists. We have extended CHARMMing's capabilities to include a fragment-based docking protocol that allows users to perform molecular docking and virtual screening calculations either directly via the CHARMMing Web server or on computing resources using the self-contained job scripts generated via the Web interface. The docking protocol was evaluated by performing a series of "re-dockings" with direct comparison to top commercial docking software. Results of this evaluation showed that CHARMMing's docking implementation is comparable to many widely used software packages and validates the use of the new CHARMM generalized force field for docking and virtual screening.

  3. Ligand-based virtual screening and inductive learning for identification of SIRT1 inhibitors in natural products.

    PubMed

    Sun, Yunan; Zhou, Hui; Zhu, Hongmei; Leung, Siu-wai

    2016-01-25

    Sirtuin 1 (SIRT1) is a nicotinamide adenine dinucleotide-dependent deacetylase, and its dysregulation can lead to ageing, diabetes, and cancer. From 346 experimentally confirmed SIRT1 inhibitors, an inhibitor structure pattern was generated by inductive logic programming (ILP) with DMax Chemistry Assistant software. The pattern contained amide, amine, and hetero-aromatic five-membered rings, each of which had a hetero-atom and an unsubstituted atom at a distance of 2. According to this pattern, a ligand-based virtual screening of 1 444 880 active compounds from Chinese herbs identified 12 compounds as inhibitors of SIRT1. Three compounds (ZINC08790006, ZINC08792229, and ZINC08792355) had high affinity (-7.3, -7.8, and -8.6 kcal/mol, respectively) for SIRT1 as estimated by molecular docking software AutoDock Vina. This study demonstrated a use of ILP and background knowledge in machine learning to facilitate virtual screening.

  4. Ligand-based virtual screening and inductive learning for identification of SIRT1 inhibitors in natural products

    NASA Astrophysics Data System (ADS)

    Sun, Yunan; Zhou, Hui; Zhu, Hongmei; Leung, Siu-Wai

    2016-01-01

    Sirtuin 1 (SIRT1) is a nicotinamide adenine dinucleotide-dependent deacetylase, and its dysregulation can lead to ageing, diabetes, and cancer. From 346 experimentally confirmed SIRT1 inhibitors, an inhibitor structure pattern was generated by inductive logic programming (ILP) with DMax Chemistry Assistant software. The pattern contained amide, amine, and hetero-aromatic five-membered rings, each of which had a hetero-atom and an unsubstituted atom at a distance of 2. According to this pattern, a ligand-based virtual screening of 1 444 880 active compounds from Chinese herbs identified 12 compounds as inhibitors of SIRT1. Three compounds (ZINC08790006, ZINC08792229, and ZINC08792355) had high affinity (-7.3, -7.8, and -8.6 kcal/mol, respectively) for SIRT1 as estimated by molecular docking software AutoDock Vina. This study demonstrated a use of ILP and background knowledge in machine learning to facilitate virtual screening.

  5. Combinatorial electrochemical synthesis and screening of Pt-WO3 catalysts for electro-oxidation of methanol

    NASA Astrophysics Data System (ADS)

    Jayaraman, Shrisudersan; Baeck, Sung-Hyeon; Jaramillo, Thomas F.; Kleiman-Shwarsctein, Alan; McFarland, Eric W.

    2005-06-01

    An automated system for high-throughput electrochemical synthesis and screening of fuel cell electro-oxidation catalysts is described. This system consists of an electrode probe that contains counter and reference electrodes that can be positioned inside an array of electrochemical cells created within a polypropylene block. The electrode probe is attached to an automated of X-Y-Z motion system. An externally controlled potentiostat is used to apply the electrochemical potential to the catalyst substrate. The motion and electrochemical control are integrated using a user-friendly software interface. During automated synthesis the deposition potential and/or current may be controlled by a pulse program triggered by the software using a data acquisition board. The screening includes automated experiments to obtain cyclic voltammograms. As an example, a platinum-tungsten oxide (Pt-WO3) library was synthesized and characterized for reactivity towards methanol electro-oxidation.

  6. Localization-based super-resolution imaging meets high-content screening.

    PubMed

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  7. Segmentation and automated measurement of chronic wound images: probability map approach

    NASA Astrophysics Data System (ADS)

    Ahmad Fauzi, Mohammad Faizal; Khansa, Ibrahim; Catignani, Karen; Gordillo, Gayle; Sen, Chandan K.; Gurcan, Metin N.

    2014-03-01

    estimated 6.5 million patients in the United States are affected by chronic wounds, with more than 25 billion US dollars and countless hours spent annually for all aspects of chronic wound care. There is need to develop software tools to analyze wound images that characterize wound tissue composition, measure their size, and monitor changes over time. This process, when done manually, is time-consuming and subject to intra- and inter-reader variability. In this paper, we propose a method that can characterize chronic wounds containing granulation, slough and eschar tissues. First, we generate a Red-Yellow-Black-White (RYKW) probability map, which then guides the region growing segmentation process. The red, yellow and black probability maps are designed to handle the granulation, slough and eschar tissues, respectively found in wound tissues, while the white probability map is designed to detect the white label card for measurement calibration purpose. The innovative aspects of this work include: 1) Definition of a wound characteristics specific probability map for segmentation, 2) Computationally efficient regions growing on 4D map; 3) Auto-calibration of measurements with the content of the image. The method was applied on 30 wound images provided by the Ohio State University Wexner Medical Center, with the ground truth independently generated by the consensus of two clinicians. While the inter-reader agreement between the readers is 85.5%, the computer achieves an accuracy of 80%.

  8. Quantitative evaluation of the memory bias effect in ROC studies with PET/CT

    NASA Astrophysics Data System (ADS)

    Kallergi, Maria; Pianou, Nicoletta; Georgakopoulos, Alexandros; Kafiri, Georgia; Pavlou, Spiros; Chatziioannou, Sofia

    2012-02-01

    PURPOSE. The purpose of the study was to evaluate the memory bias effect in ROC experiments with tomographic data and, specifically, in the evaluation of two different PET/CT protocols for the detection and diagnosis of recurrent thyroid cancer. MATERIALS AND METHODS. Two readers participated in an ROC experiment that evaluated tomographic images from 43 patients followed up for thyroid cancer recurrence. Readers evaluated first whole body PET/CT scans of the patients and then a combination of whole body and high-resolution head and neck scans of the same patients. The second set was read twice. Once within 48 hours of the first set and the second time at least a month later. The detection and diagnostic performances of the readers in the three reading sessions were assessed with the DBMMRMC and LABMRMC software using the area under the ROC curve as a performance index. Performances were also evaluated by comparing the number and the size of the detected abnormal foci among the three readings. RESULTS. There was no performance difference between first and second treatments. There were statistically significant differences between first and third, and second and third treatments showing that memory can seriously affect the outcome of ROC studies. CONCLUSION. Despite the fact that tomographic data involve numerous image slices per patient, the memory bias effect is present and substantial and should be carefully eliminated from analogous ROC experiments.

  9. Computational Thermodynamics of Materials Zi-Kui Liu and Yi Wang

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devanathan, Ram

    This authoritative volume introduces the reader to computational thermodynamics and the use of this approach to the design of material properties by tailoring the chemical composition. The text covers applications of this approach, introduces the relevant computational codes, and offers exercises at the end of each chapter. The book has nine chapters and two appendices that provide background material on computer codes. Chapter 1 covers the first and second laws of thermodynamics, introduces the spinodal as the limit of stability, and presents the Gibbs-Duhem equation. Chapter 2 focuses on the Gibbs energy function. Starting with a homogeneous system with amore » single phase, the authors proceed to phases with variable compositions, and polymer blends. The discussion includes the contributions of external electric and magnetic fields to the Gibbs energy. Chapter 3 deals with phase equilibria in heterogeneous systems, the Gibbs phase rule, and phase diagrams. Chapter 4 briefly covers experimental measurements of thermodynamic properties used as input for thermodynamic modeling by Calculation of Phase Diagrams (CALPHAD). Chapter 5 discusses the use of density functional theory to obtain thermochemical data and fill gaps where experimental data is missing. The reader is introduced to the Vienna Ab Initio Simulation Package (VASP) for density functional theory and the YPHON code for phonon calculations. Chapter 6 introduces the modeling of Gibbs energy of phases with the CALPHAD method. Chapter 7 deals with chemical reactions and the Ellingham diagram for metal-oxide systems and presents the calculation of the maximum reaction rate from equilibrium thermodynamics. Chapter 8 is devoted to electrochemical reactions and Pourbaix diagrams with application examples. Chapter 9 concludes this volume with the application of a model of multiple microstates to Ce and Fe3Pt. CALPHAD modeling is briefly discussed in the context of genomics of materials. The book introduces basic thermodynamic concepts clearly and directs readers to appropriate references for advanced concepts and details of software implementation. The list of references is quite comprehensive. The authors make liberal use of diagrams to illustrate key concepts. The two Appendices at the end discuss software requirements and the file structure, and present templates for special quasi-random structures. There is also a link to download pre-compiled binary files of the YPHON code for Linux or Microsoft Windows systems. The exercises at the end of the chapters assume that the reader has access to VASP, which is not freeware. Readers without access to this code can work on a limited number of exercises. However, results from other first principles codes can be organized in the YPHON format as explained in the Appendix. This book will serve as an excellent reference on computational thermodynamics and the exercises provided at the end of each chapter make it valuable as a graduate level textbook. Reviewer: Ram Devanathan is Acting Director of Earth Systems Science Division, Pacific Northwest National Laboratory, USA.« less

  10. Chapter 24: Programmatic Interfaces - IDL VOlib

    NASA Astrophysics Data System (ADS)

    Miller, C. J.

    In this chapter, we describe a library for working with the VO using IDL (the Interactive Data Language). IDL is a software environment for data analysis, visualization, and cross-platform application development. It has wide-usage in astronomy, including NASA (e.g. http://seadas.gsfc.nasa.gov/), the Sloan Digital Sky Survey (http://www.sdss.org), and the Spitzer Infrared Spectrograph Instrument (http://ssc.spitzer.caltech.edu/archanaly/contributed/smart/). David Stern, the founder of Research Systems, Inc. (RSI), began the development of IDL while working with NASA's Mars Mariner 7 and 9 data at the Laboratory for Atmospheric and Space Physics at the University of Colorado. In 1981, IDL was rewritten in assembly language and FORTRAN for VAX/VMS. IDL's usage has expanded over the last decade into the fields of medical imaging and engineering, among many others. IDL's programming style carries over much of this FORTRAN-legacy, and has a familiar feel to many astronomers who learned their trade using FORTRAN. The spread of IDL-usage amongst astronomers can in part be attributed to the wealth of publicly astronomical libraries. The Goddard Space Flight Center (GSFC) maintains a list of astronomy-related IDL libraries, including the well known Astronomy User's Library (hereafter ASTROLIB2). We will use some of these GSFC IDL libraries. We note that while IDL is a licensed-software product, the source code of user-written procedures are typically freely available to the community. To make the most out of this section as a reader, it is important that many of the data discovery, access, and analysis protocols are understood before reading this chapter. In the next section, we provide an overview of some of the NVO terminology with which the reader should be familiar. The IDL library discussed here is specifically for use with the Virtual Observatory and is named VOlib. IDL's VOlib is available at http://nvo.noao.edu and is included with the software distrubution for this book.

  11. Results obtained with a low cost software-based audiometer for hearing screening.

    PubMed

    Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis

    2013-07-01

     The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening.  To evaluate the TS audiometer for conducting audiometric screening.  A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated.  For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively.  The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

  12. Effects of a Periodic Disturbance on Structure and Mixing in Turbulent Shear Layers and Wakes

    DTIC Science & Technology

    1985-01-01

    needs to be separated into four different cases corresponding to initial locations in one of four quadrants about the vortex center. The four cases are...replaced with a pair of two-inch honey- combs spaced two inches apart. Each honeycomb had a chopper screen on the downstream end. The reader is refered to...34 " ’ -... ’ ’ .... oe -13- . relevant information on the absorption method are discussed in Appendix A. During the absorption runs, four

  13. Computers in health care for the 21st century.

    PubMed

    O'Desky, R I; Ball, M J; Ball, E E

    1990-03-01

    As the world enters the last decade of the 20th Century, there is a great deal of speculation about the effect of computers on the future delivery of health care. In this article, the authors attempt to identify some of the evolving computer technologies and anticipate what effect they will have by the year 2000. Rather than listing potential accomplishments, each of the affected areas: hardware, software, health care systems and communications, are presented in an evolutionary manner so the reader can better appreciate where we have been and where we are going.

  14. Desktop system for accounting, audit, and research in A&E.

    PubMed Central

    Taylor, C J; Brain, S G; Bull, F; Crosby, A C; Ferguson, D G

    1997-01-01

    The development of a database for audit, research, and accounting in accident and emergency (A&E) is described. The system uses a desktop computer, an optical scanner, sophisticated optical mark reader software, and workload management data. The system is highly flexible, easy to use, and at a cost of around 16,000 pounds affordable for larger departments wishing to move towards accounting. For smaller departments, it may be an alternative to full computerisation. Images Figure 1 Figure 2 Figure 3 Figure 5 Figure 6 PMID:9132200

  15. The effect of radiation dose reduction on computer-aided detection (CAD) performance in a low-dose lung cancer screening population.

    PubMed

    Young, Stefano; Lo, Pechin; Kim, Grace; Brown, Matthew; Hoffman, John; Hsu, William; Wahi-Anwar, Wasil; Flores, Carlos; Lee, Grace; Noo, Frederic; Goldin, Jonathan; McNitt-Gray, Michael

    2017-04-01

    Lung cancer screening with low-dose CT has recently been approved for reimbursement, heralding the arrival of such screening services worldwide. Computer-aided detection (CAD) tools offer the potential to assist radiologists in detecting nodules in these screening exams. In lung screening, as in all CT exams, there is interest in further reducing radiation dose. However, the effects of continued dose reduction on CAD performance are not fully understood. In this work, we investigated the effect of reducing radiation dose on CAD lung nodule detection performance in a screening population. The raw projection data files were collected from 481 patients who underwent low-dose screening CT exams at our institution as part of the National Lung Screening Trial (NLST). All scans were performed on a multidetector scanner (Sensation 64, Siemens Healthcare, Forchheim Germany) according to the NLST protocol, which called for a fixed tube current scan of 25 effective mAs for standard-sized patients and 40 effective mAs for larger patients. The raw projection data were input to a reduced-dose simulation software to create simulated reduced-dose scans corresponding to 50% and 25% of the original protocols. All raw data files were reconstructed at the scanner with 1 mm slice thickness and B50 kernel. The lungs were segmented semi-automatically, and all images and segmentations were input to an in-house CAD algorithm trained on higher dose scans (75-300 mAs). CAD findings were compared to a reference standard generated by an experienced reader. Nodule- and patient-level sensitivities were calculated along with false positives per scan, all of which were evaluated in terms of the relative change with respect to dose. Nodules were subdivided based on size and solidity into categories analogous to the LungRADS assessment categories, and sub-analyses were performed. From the 481 patients in this study, 82 had at least one nodule (prevalence of 17%) and 399 did not (83%). A total of 118 nodules were identified. Twenty-seven nodules (23%) corresponded to LungRADS category 4 based on size and composition, while 18 (15%) corresponded to LungRADS category 3 and 73 (61%) corresponded to LungRADS category 2. For solid nodules ≥8 mm, patient-level median sensitivities were 100% at all three dose levels, and mean sensitivities were 72%, 63%, and 63% at original, 50%, and 25% dose, respectively. Overall mean patient-level sensitivities for nodules ranging from 3 to 45 mm were 38%, 37%, and 38% at original, 50%, and 25% dose due to the prevalence of smaller nodules and nonsolid nodules in our reference standard. The mean false-positive rates were 3, 5, and 13 per case. CAD sensitivity decreased very slightly for larger nodules as dose was reduced, indicating that reducing the dose to 50% of original levels may be investigated further for use in CT screening. However, the effect of dose was small relative to the effect of the nodule size and solidity characteristics. The number of false positives per scan increased substantially at 25% dose, illustrating the importance of tuning CAD algorithms to very challenging, high-noise screening exams. © 2017 American Association of Physicists in Medicine.

  16. Internet-Based Cervical Cancer Screening Program

    DTIC Science & Technology

    2008-05-01

    information technology have facilitated the Internet transmission and archival storage of digital images and other clinical information . The combination of...Phase included: 1) development of hardware, software, and interfaces between computerized scanning device and Internet - linked servers and reading...AD_________________ Award Number: W81XWH-04-C-0083 TITLE: Internet -Based Cervical Cancer Screening

  17. Capture Their Attention: Capturing Lessons Using Screen Capture Software

    ERIC Educational Resources Information Center

    Drumheller, Kristina; Lawler, Gregg

    2011-01-01

    When students miss classes for university activities such as athletic and academic events, they inevitably miss important class material. Students can get notes from their peers or visit professors to find out what they missed, but when students miss new and challenging material these steps are sometimes not enough. Screen capture and recording…

  18. Exploratory visualization software for reporting environmental survey results.

    PubMed

    Fisher, P; Arnot, C; Bastin, L; Dykes, J

    2001-08-01

    Environmental surveys yield three principal products: maps, a set of data tables, and a textual report. The relationships between these three elements, however, are often cumbersome to present, making full use of all the information in an integrated and systematic sense difficult. The published paper report is only a partial solution. Modern developments in computing, particularly in cartography, GIS, and hypertext, mean that it is increasingly possible to conceive of an easier and more interactive approach to the presentation of such survey results. Here, we present such an approach which links map and tabular datasets arising from a vegetation survey, allowing users ready access to a complex dataset using dynamic mapping techniques. Multimedia datasets equipped with software like this provide an exciting means of quick and easy visual data exploration and comparison. These techniques are gaining popularity across the sciences as scientists and decision-makers are presented with increasing amounts of diverse digital data. We believe that the software environment actively encourages users to make complex interrogations of the survey information, providing a new vehicle for the reader of an environmental survey report.

  19. Detailed analysis of complex single molecule FRET data with the software MASH

    NASA Astrophysics Data System (ADS)

    Hadzic, Mélodie C. A. S.; Kowerko, Danny; Börner, Richard; Zelger-Paulus, Susann; Sigel, Roland K. O.

    2016-04-01

    The processing and analysis of surface-immobilized single molecule FRET (Förster resonance energy transfer) data follows systematic steps (e.g. single molecule localization, clearance of different sources of noise, selection of the conformational and kinetic model, etc.) that require a solid knowledge in optics, photophysics, signal processing and statistics. The present proceeding aims at standardizing and facilitating procedures for single molecule detection by guiding the reader through an optimization protocol for a particular experimental data set. Relevant features were determined from single molecule movies (SMM) imaging Cy3- and Cy5-labeled Sc.ai5γ group II intron molecules synthetically recreated, to test the performances of four different detection algorithms. Up to 120 different parameterizations per method were routinely evaluated to finally establish an optimum detection procedure. The present protocol is adaptable to any movie displaying surface-immobilized molecules, and can be easily reproduced with our home-written software MASH (multifunctional analysis software for heterogeneous data) and script routines (both available in the download section of www.chem.uzh.ch/rna).

  20. Development of Microtiter Plate Culture Method for Rapid Screening of ε-Poly-L-Lysine-Producing Strains.

    PubMed

    Liu, Yong-Juan; Chen, Xu-Sheng; Zhao, Jun-Jie; Pan, Long; Mao, Zhong-Gui

    2017-12-01

    ε-Poly-L-lysine (ε-PL) produced by Streptomyces albulus possesses a broad spectrum of antimicrobial activity and is widely used as a food preservative. To extensively screen ε-PL-overproducing strain, we developed an integrated high-throughput screening assay using ribosome engineering technology. The production protocol was scaled down to 24- and 48-deep-well microtiter plates (MTPs). The microplate reader assay was used to monitor ε-PL production. A good correlation was observed between the fermentation results obtained in both 24-(48)-deep-well MTPs and conventional Erlenmeyer flasks. Using this protocol, the production of ε-PL in an entire MTP was determined in <5 min without compromising on accuracy. The high-yielding strain selected through this protocol was also tested in Erlenmeyer flasks. The result showed that the ε-PL production of the high-yielding mutants was nearly 45% higher than that of the parent stain. Thus, development of this protocol is expected to accelerate the selection of ε-PL-overproducing strains.

Top