Sample records for screen recording software

  1. That's Infotainment!: How to Create Your Own Screencasts

    ERIC Educational Resources Information Center

    Kroski, Ellyssa

    2009-01-01

    Screencasts are videos that record the actions that take place on the computer screen, most often including a narrative audio track, in order to demonstrate various computer-related tasks, such as how to use a software program or navigate a certain Web site. All that is needed is a standard microphone and screen recording software, which can be…

  2. ScreenRecorder: A Utility for Creating Screenshot Video Using Only Original Equipment Manufacturer (OEM) Software on Microsoft Windows Systems

    DTIC Science & Technology

    2015-01-01

    class within Microsoft Visual Studio . 2 It has been tested on and is compatible with Microsoft Vista, 7, and 8 and Visual Studio Express 2008...the ScreenRecorder utility assumes a basic understanding of compiling and running C++ code within Microsoft Visual Studio . This report does not...of Microsoft Visual Studio , the ScreenRecorder utility was developed as a C++ class that can be compiled as a library (static or dynamic) to be

  3. Development and use of behavior and social interaction software installed on Palm handheld for observation of a child's social interactions with the environment.

    PubMed

    Sarkar, Archana; Dutta, Arup; Dhingra, Usha; Dhingra, Pratibha; Verma, Priti; Juyal, Rakesh; Black, Robert E; Menon, Venugopal P; Kumar, Jitendra; Sazawal, Sunil

    2006-08-01

    In settings in developing countries, children often socialize with multiple socializing agents (peers, siblings, neighbors) apart from their parents, and thus, a measurement of a child's social interactions should be expanded beyond parental interactions. Since the environment plays a role in shaping a child's development, the measurement of child-socializing agents' interactions is important. We developed and used a computerized observational software Behavior and Social Interaction Software (BASIS) with a preloaded coding scheme installed on a handheld Palm device to record complex observations of interactions between children and socializing agents. Using BASIS, social interaction assessments were conducted on 573 preschool children for 1 h in their natural settings. Multiple screens with a set of choices in each screen were designed that included the child's location, broad activity, state, and interactions with child-socializing agents. Data were downloaded onto a computer and systematically analyzed. BASIS, installed on Palm OS (M-125), enabled the recording of the complex interactions of child-socializing agents that could not be recorded with manual forms. Thus, this tool provides an innovative and relatively accurate method for the systematic recording of social interactions in an unrestricted environment.

  4. Mobile Care (Moca) for Remote Diagnosis and Screening

    PubMed Central

    Celi, Leo Anthony; Sarmenta, Luis; Rotberg, Jhonathan; Marcelo, Alvin; Clifford, Gari

    2010-01-01

    Moca is a cell phone-facilitated clinical information system to improve diagnostic, screening and therapeutic capabilities in remote resource-poor settings. The software allows transmission of any medical file, whether a photo, x-ray, audio or video file, through a cell phone to (1) a central server for archiving and incorporation into an electronic medical record (to facilitate longitudinal care, quality control, and data mining), and (2) a remote specialist for real-time decision support (to leverage expertise). The open source software is designed as an end-to-end clinical information system that seamlessly connects health care workers to medical professionals. It is integrated with OpenMRS, an existing open source medical records system commonly used in developing countries. PMID:21822397

  5. Empirical Data Collection and Analysis Using Camtasia and Transana

    ERIC Educational Resources Information Center

    Thorsteinsson, Gisli; Page, Tom

    2009-01-01

    One of the possible techniques for collecting empirical data is video recordings of a computer screen with specific screen capture software. This method for collecting empirical data shows how students use the BSCWII (Be Smart Cooperate Worldwide--a web based collaboration/groupware environment) to coordinate their work and collaborate in…

  6. Observations on online educational materials for powder diffraction crystallography software.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toby, B. H.

    2010-10-01

    This article presents a series of approaches used to educate potential users of crystallographic software for powder diffraction. The approach that has been most successful in the author's opinion is the web lecture, where an audio presentation is coupled to a video-like record of the contents of the presenter's computer screen.

  7. Designing Colorectal Cancer Screening Decision Support: A Cognitive Engineering Enterprise.

    PubMed

    Militello, Laura G; Saleem, Jason J; Borders, Morgan R; Sushereba, Christen E; Haverkamp, Donald; Wolf, Steven P; Doebbeling, Bradley N

    2016-03-01

    Adoption of clinical decision support has been limited. Important barriers include an emphasis on algorithmic approaches to decision support that do not align well with clinical work flow and human decision strategies, and the expense and challenge of developing, implementing, and refining decision support features in existing electronic health records (EHRs). We applied decision-centered design to create a modular software application to support physicians in managing and tracking colorectal cancer screening. Using decision-centered design facilitates a thorough understanding of cognitive support requirements from an end user perspective as a foundation for design. In this project, we used an iterative design process, including ethnographic observation and cognitive task analysis, to move from an initial design concept to a working modular software application called the Screening & Surveillance App. The beta version is tailored to work with the Veterans Health Administration's EHR Computerized Patient Record System (CPRS). Primary care providers using the beta version Screening & Surveillance App more accurately answered questions about patients and found relevant information more quickly compared to those using CPRS alone. Primary care providers also reported reduced mental effort and rated the Screening & Surveillance App positively for usability.

  8. Designing Colorectal Cancer Screening Decision Support: A Cognitive Engineering Enterprise

    PubMed Central

    Militello, Laura G.; Saleem, Jason J.; Borders, Morgan R.; Sushereba, Christen E.; Haverkamp, Donald; Wolf, Steven P.; Doebbeling, Bradley N.

    2016-01-01

    Adoption of clinical decision support has been limited. Important barriers include an emphasis on algorithmic approaches to decision support that do not align well with clinical work flow and human decision strategies, and the expense and challenge of developing, implementing, and refining decision support features in existing electronic health records (EHRs). We applied decision-centered design to create a modular software application to support physicians in managing and tracking colorectal cancer screening. Using decision-centered design facilitates a thorough understanding of cognitive support requirements from an end user perspective as a foundation for design. In this project, we used an iterative design process, including ethnographic observation and cognitive task analysis, to move from an initial design concept to a working modular software application called the Screening & Surveillance App. The beta version is tailored to work with the Veterans Health Administration’s EHR Computerized Patient Record System (CPRS). Primary care providers using the beta version Screening & Surveillance App more accurately answered questions about patients and found relevant information more quickly compared to those using CPRS alone. Primary care providers also reported reduced mental effort and rated the Screening & Surveillance App positively for usability. PMID:26973441

  9. Screencasts

    ERIC Educational Resources Information Center

    Yee, Kevin; Hargis, Jace

    2010-01-01

    This article discusses the benefits of screencasts and its instructional uses. Well-known for some years to advanced technology users, Screen Capture Software (SCS) offers the promise of recording action on the computer desktop together with voiceover narration, all combined into a single movie file that can be shared, emailed, or uploaded.…

  10. An experience of qualified preventive screening: shiraz smart screening software.

    PubMed

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  11. Evaluation of a New Patient Record System Using the Optical Card

    PubMed Central

    Brown, J.H.U.; Vallbona, Carlos; Shoda, Junji; Albin, Jean

    1989-01-01

    A new form of patient record has been devised in which a laser imprinted card is coupled to a p.c. for data input and output. Entry of data is simple and recall of any datum requires only a keystroke. Any part of the data can be readily accessed through a software system which encompasses a variety of screens and menus to summarize and combine data. The complete system has been under test in a community health clinic and at NASA and results to date are satisfactory. Preliminary evaluation indicates that the system has no hardware problems, that the software is suitable for the purpose, that patients carry the card and return with it at succeeding visits, that physicians accept that card for a medical record and are pleased with the speed of access and the organization of the data.

  12. Desktop software to identify patients eligible for recruitment into a clinical trial: using SARMA to recruit to the ROAD feasibility trial.

    PubMed

    Treweek, Shaun; Pearson, Ewan; Smith, Natalie; Neville, Ron; Sargeant, Paul; Boswell, Brian; Sullivan, Frank

    2010-01-01

    Recruitment to trials in primary care is often difficult, particularly when practice staff need to identify study participants with acute conditions during consultations. The Scottish Acute Recruitment Management Application (SARMA) system is linked to general practice electronic medical record (EMR) systems and is designed to provide recruitment support to multi-centre trials by screening patients against trial inclusion criteria and alerting practice staff if the patient appears eligible. For patients willing to learn more about the trial, the software allows practice staff to send the patient's contact details to the research team by text message. To evaluate the ability of the software to support trial recruitment. Software evaluation embedded in a randomised controlled trial. Five general practices in Tayside and Fife, Scotland. SARMA was used to support recruitment to a feasibility trial (the Response to Oral Agents in Diabetes, or ROAD trial) looking at users of oral therapy in diabetes. The technical performance of the software and its utility as a recruitment tool were evaluated. The software was successfully installed at four of the five general practices and recruited 11 of the 29 participants for ROAD (other methods were letter and direct invitation by a practice nurse) and had a recruitment return of 35% (11 of 31 texts sent led to a recruitment). Screen failures were relatively low (7 of 31 referred). Practice staff members were positive about the system. An automated recruitment tool can support primary care trials in Scotland and has the potential to support recruitment in other jurisdictions. It offers a low-cost supplement to other trial recruitment methods and is likely to have a much lower screen failure rate than blanket approaches such as mailshots and newspaper campaigns.

  13. Portable Electromyograph

    NASA Technical Reports Server (NTRS)

    De Luca, Gianluca; De Luca, Carlo J.; Bergman, Per

    2004-01-01

    A portable electronic apparatus records electromyographic (EMG) signals in as many as 16 channels at a sampling rate of 1,024 Hz in each channel. The apparatus (see figure) includes 16 differential EMG electrodes (each electrode corresponding to one channel) with cables and attachment hardware, reference electrodes, an input/output-and-power-adapter unit, a 16-bit analog-to-digital converter, and a hand-held computer that contains a removable 256-MB flash memory card. When all 16 EMG electrodes are in use, full-bandwidth data can be recorded in each channel for as long as 8 hours. The apparatus is powered by a battery and is small enough that it can be carried in a waist pouch. The computer is equipped with a small screen that can be used to display the incoming signals on each channel. Amplitude and time adjustments of this display can be made easily by use of touch buttons on the screen. The user can also set up a data-acquisition schedule to conform to experimental protocols or to manage battery energy and memory efficiently. Once the EMG data have been recorded, the flash memory card is removed from the EMG apparatus and placed in a flash-memory- card-reading external drive unit connected to a personal computer (PC). The PC can then read the data recorded in the 16 channels. Preferably, before further analysis, the data should be stored in the hard drive of the PC. The data files are opened and viewed on the PC by use of special- purpose software. The software for operation of the apparatus resides in a random-access memory (RAM), with backup power supplied by a small internal lithium cell. A backup copy of this software resides on the flash memory card. In the event of loss of both main and backup battery power and consequent loss of this software, the backup copy can be used to restore the RAM copy after power has been restored. Accessories for this device are also available. These include goniometers, accelerometers, foot switches, and force gauges.

  14. Data recording and trend display during anaesthesia using 'MacLab'.

    PubMed

    Kennedy, R R

    1991-08-01

    A single screen display of variables monitored during anaesthesia may be ergonomically superior to the 'stack' of monitors seen in many anaesthetising locations. A system based on a MacLab (Analogue Digital Instruments) analogue-to-digital convertor used in conjunction with a Macintosh computer was evaluated. The system was configured to provide trend displays of up to eight variables on a single screen. It was found to be a useful adjunct to monitoring during anaesthesia. Advantages of this system are low cost, flexibility, and the quality of the software and support provided. Limitations of this and other similar systems are discussed.

  15. Natural 3D content on glasses-free light-field 3D cinema

    NASA Astrophysics Data System (ADS)

    Balogh, Tibor; Nagy, Zsolt; Kovács, Péter Tamás.; Adhikarla, Vamsi K.

    2013-03-01

    This paper presents a complete framework for capturing, processing and displaying the free viewpoint video on a large scale immersive light-field display. We present a combined hardware-software solution to visualize free viewpoint 3D video on a cinema-sized screen. The new glasses-free 3D projection technology can support larger audience than the existing autostereoscopic displays. We introduce and describe our new display system including optical and mechanical design considerations, the capturing system and render cluster for producing the 3D content, and the various software modules driving the system. The indigenous display is first of its kind, equipped with front-projection light-field HoloVizio technology, controlling up to 63 MP. It has all the advantages of previous light-field displays and in addition, allows a more flexible arrangement with a larger screen size, matching cinema or meeting room geometries, yet simpler to set-up. The software system makes it possible to show 3D applications in real-time, besides the natural content captured from dense camera arrangements as well as from sparse cameras covering a wider baseline. Our software system on the GPU accelerated render cluster, can also visualize pre-recorded Multi-view Video plus Depth (MVD4) videos on this light-field glasses-free cinema system, interpolating and extrapolating missing views.

  16. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents.

    PubMed

    Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise

    2013-06-04

    Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study is its generalizability. Future research should address this limitation and may explore alternative approaches to software documentation, such as modular manuals or participatory design.

  17. Privacy-preserving screen capture: towards closing the loop for health IT usability.

    PubMed

    Cooley, Joseph; Smith, Sean

    2013-08-01

    As information technology permeates healthcare (particularly provider-facing systems), maximizing system effectiveness requires the ability to document and analyze tricky or troublesome usage scenarios. However, real-world health IT systems are typically replete with privacy-sensitive data regarding patients, diagnoses, clinicians, and EMR user interface details; instrumentation for screen capture (capturing and recording the scenario depicted on the screen) needs to respect these privacy constraints. Furthermore, real-world health IT systems are typically composed of modules from many sources, mission-critical and often closed-source; any instrumentation for screen capture can rely neither on access to structured output nor access to software internals. In this paper, we present a tool to help solve this problem: a system that combines keyboard video mouse (KVM) capture with automatic text redaction (and interactively selectable unredaction) to produce precise technical content that can enrich stakeholder communications and improve end-user influence on system evolution. KVM-based capture makes our system both application-independent and OS-independent because it eliminates software-interface dependencies on capture targets. Using a corpus of EMR screenshots, we present empirical measurements of redaction effectiveness and processing latency to demonstrate system performances. We discuss how these techniques can translate into instrumentation systems that improve real-world health IT deployments. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. OPEN-SOURCE SOFTWARE IN DENTISTRY: A SYSTEMATIC REVIEW.

    PubMed

    Chruściel-Nogalska, Małgorzata; Smektała, Tomasz; Tutak, Marcin; Sporniak-Tutak, Katarzyna; Olszewski, Raphael

    2017-01-01

    Technological development and the need for electronic health records management resulted in the need for a computer with dedicated, commercial software in daily dental practice. The alternative for commercial software may be open-source solutions. Therefore, this study reviewed the current literature on the availability and use of open-source software (OSS) in dentistry. A comprehensive database search was performed on February 1, 2017. Only articles published in peer-reviewed journals with a focus on the use or description of OSS were retrieved. The level of evidence, according to Oxford EBM Centre Levels of Evidence Scale was classified for all studies. Experimental studies underwent additional quality reporting assessment. The screening and evaluation process resulted in twenty-one studies from 1,940 articles found, with 10 of them being experimental studies. None of the articles provided level 1 evidence, and only one study was considered high quality following quality assessment. Twenty-six different OSS programs were described in the included studies of which ten were used for image visualization, five were used for healthcare records management, four were used for educations processes, one was used for remote consultation and simulation, and six were used for general purposes. Our analysis revealed that the dental literature on OSS consists of scarce, incomplete, and methodologically low quality information.

  19. Screen Design Principles of Computer-Aided Instructional Software for Elementary School Students

    ERIC Educational Resources Information Center

    Berrin, Atiker; Turan, Bülent Onur

    2017-01-01

    This study aims to present primary school students' views about current educational software interfaces, and to propose principles for educational software screens. The study was carried out with a general screening model. Sample group of the study consisted of sixth grade students in Sehit Ögretmen Hasan Akan Elementary School. In this context,…

  20. "Diagnosis by behavioral observation" home-videosomnography - a rigorous ethnographic approach to sleep of children with neurodevelopmental conditions.

    PubMed

    Ipsiroglu, Osman S; Hung, Yi-Hsuan Amy; Chan, Forson; Ross, Michelle L; Veer, Dorothee; Soo, Sonja; Ho, Gloria; Berger, Mai; McAllister, Graham; Garn, Heinrich; Kloesch, Gerhard; Barbosa, Adriano Vilela; Stockler, Sylvia; McKellin, William; Vatikiotis-Bateson, Eric

    2015-01-01

    Advanced video technology is available for sleep-laboratories. However, low-cost equipment for screening in the home setting has not been identified and tested, nor has a methodology for analysis of video recordings been suggested. We investigated different combinations of hardware/software for home-videosomnography (HVS) and established a process for qualitative and quantitative analysis of HVS-recordings. A case vignette (HVS analysis for a 5.5-year-old girl with major insomnia and several co-morbidities) demonstrates how methodological considerations were addressed and how HVS added value to clinical assessment. We suggest an "ideal set of hardware/software" that is reliable, affordable (∼$500) and portable (=2.8 kg) to conduct non-invasive HVS, which allows time-lapse analyses. The equipment consists of a net-book, a camera with infrared optics, and a video capture device. (1) We present an HVS-analysis protocol consisting of three steps of analysis at varying replay speeds: (a) basic overview and classification at 16× normal speed; (b) second viewing and detailed descriptions at 4-8× normal speed, and (c) viewing, listening, and in-depth descriptions at real-time speed. (2) We also present a custom software program that facilitates video analysis and note-taking (Annotator(©)), and Optical Flow software that automatically quantifies movement for internal quality control of the HVS-recording. The case vignette demonstrates how the HVS-recordings revealed the dimension of insomnia caused by restless legs syndrome, and illustrated the cascade of symptoms, challenging behaviors, and resulting medications. The strategy of using HVS, although requiring validation and reliability testing, opens the floor for a new "observational sleep medicine," which has been useful in describing discomfort-related behavioral movement patterns in patients with communication difficulties presenting with challenging/disruptive sleep/wake behaviors.

  1. Can an alert in primary care electronic medical records increase participation in a population-based screening programme for colorectal cancer? COLO-ALERT, a randomised clinical trial

    PubMed Central

    2014-01-01

    Background Colorectal cancer is an important public health problem in Spain. Over the last decade, several regions have carried out screening programmes, but population participation rates remain below recommended European goals. Reminders on electronic medical records have been identified as a low-cost and high-reach strategy to increase participation. Further knowledge is needed about their effect in a population-based screening programme. The main aim of this study is to evaluate the effectiveness of an electronic reminder to promote the participation in a population-based colorectal cancer screening programme. Secondary aims are to learn population’s reasons for refusing to take part in the screening programme and to find out the health professionals’ opinion about the official programme implementation and on the new computerised tool. Methods/Design This is a parallel randomised trial with a cross-sectional second stage. Participants: all the invited subjects to participate in the public colorectal cancer screening programme that includes men and women aged between 50–69, allocated to the eleven primary care centres of the study and all their health professionals. The randomisation unit will be the primary care physician. The intervention will consist of activating an electronic reminder, in the patient’s electronic medical record, in order to promote colorectal cancer screening, during a synchronous medical appointment, throughout the year that the intervention takes place. A comparison of the screening rates will then take place, using the faecal occult blood test of the patients from the control and the intervention groups. We will also take a questionnaire to know the opinions of the health professionals. The main outcome is the screening status at the end of the study. Data will be analysed with an intention-to-treat approach. Discussion We expect that the introduction of specific reminders in electronic medical records, as a tool to facilitate and encourage direct referral by physicians and nurse practitioners to perform colorectal cancer screening will mean an increase in participation of the target population. The introduction of this new software tool will have good acceptance and increase compliance with recommendations from health professionals. Trial registration Clinical Trials.gov identifier NCT01877018 PMID:24685117

  2. Evaluation of automated image analysis software for the detection of diabetic retinopathy to reduce the ophthalmologists' workload.

    PubMed

    Soto-Pedre, Enrique; Navea, Amparo; Millan, Saray; Hernaez-Ortega, Maria C; Morales, Jesús; Desco, Maria C; Pérez, Pablo

    2015-02-01

    To assess the safety and workload reduction of an automated 'disease/no disease' grading system for diabetic retinopathy (DR) within a systematic screening programme. Single 45° macular field image per eye was obtained from consecutive patients attending a regional primary care based DR screening programme in Valencia (Spain). The sensitivity and specificity of automated system operating as 'one or more than one microaneurysm detection for disease presence' grader were determined relative to a manual grading as gold standard. Data on age, gender and diabetes mellitus were also recorded. A total of 5278 patients with diabetes were screened. The median age and duration of diabetes was 69 years and 6.9 years, respectively. Estimated prevalence of DR was 15.6%. The software classified 43.9% of the patients as having no DR and 26.1% as having ungradable images. Detection of DR was achieved with 94.5% sensitivity (95% CI 92.6- 96.5) and 68.8% specificity (95%CI 67.2-70.4). The overall accuracy of the automated system was 72.5% (95%CI 71.1-73.9). The present retinal image processing algorithm that can act as prefilter to flag out images with pathological lesions can be implemented in practice. Our results suggest that it could be considered when implementing DR screening programmes. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Surgical Videos with Synchronised Vertical 2-Split Screens Recording the Surgeons' Hand Movement.

    PubMed

    Kaneko, Hiroki; Ra, Eimei; Kawano, Kenichi; Yasukawa, Tsutomu; Takayama, Kei; Iwase, Takeshi; Terasaki, Hiroko

    2015-01-01

    To improve the state-of-the-art teaching system by creating surgical videos with synchronised vertical 2-split screens. An ultra-compact, wide-angle point-of-view camcorder (HX-A1, Panasonic) was mounted on the surgical microscope focusing mostly on the surgeons' hand movements. In combination with the regular surgical videos obtained from the CCD camera in the surgical microscope, synchronised vertical 2-split-screen surgical videos were generated with the video-editing software. Using synchronised vertical 2-split-screen videos, residents of the ophthalmology department could watch and learn how assistant surgeons controlled the eyeball, while the main surgeons performed scleral buckling surgery. In vitrectomy, the synchronised vertical 2-split-screen videos showed the surgeons' hands holding the instruments and moving roughly and boldly, in contrast to the very delicate movements of the vitrectomy instruments inside the eye. Synchronised vertical 2-split-screen surgical videos are beneficial for the education of young surgical trainees when learning surgical skills including the surgeons' hand movements. © 2015 S. Karger AG, Basel.

  4. [Prenatal risk calculation: comparison between Fast Screen pre I plus software and ViewPoint software. Evaluation of the risk calculation algorithms].

    PubMed

    Morin, Jean-François; Botton, Eléonore; Jacquemard, François; Richard-Gireme, Anouk

    2013-01-01

    The Fetal medicine foundation (FMF) has developed a new algorithm called Prenatal Risk Calculation (PRC) to evaluate Down syndrome screening based on free hCGβ, PAPP-A and nuchal translucency. The peculiarity of this algorithm is to use the degree of extremeness (DoE) instead of the multiple of the median (MoM). The biologists measuring maternal seric markers on Kryptor™ machines (Thermo Fisher Scientific) use Fast Screen pre I plus software for the prenatal risk calculation. This software integrates the PRC algorithm. Our study evaluates the data of 2.092 patient files of which 19 show a fœtal abnormality. These files have been first evaluated with the ViewPoint software based on MoM. The link between DoE and MoM has been analyzed and the different calculated risks compared. The study shows that Fast Screen pre I plus software gives the same risk results as ViewPoint software, but yields significantly fewer false positive results.

  5. Building a virtual ligand screening pipeline using free software: a survey.

    PubMed

    Glaab, Enrico

    2016-03-01

    Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. © The Author 2015. Published by Oxford University Press.

  6. Building a virtual ligand screening pipeline using free software: a survey

    PubMed Central

    2016-01-01

    Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. PMID:26094053

  7. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents

    PubMed Central

    Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R.; Lemieux-Charles, Louise

    2015-01-01

    Research problem Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. Research question What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Literature review Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. Methodology We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. Results and discussion The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study is its generalizability. Future research should address this limitation and may explore alternative approaches to software documentation, such as modular manuals or participatory design. PMID:26190888

  8. Comparative analysis of data base management systems

    NASA Technical Reports Server (NTRS)

    Smith, R.

    1983-01-01

    A study to determine if the Remote File Inquiry (RFI) system would handle the future requirements of the user community is discussed. RFI is a locally written and locally maintained on-line query/update package. The current and future on-line requirements of the user community were studied. Additional consideration was given to the types of data structuring the users required. The survey indicated the features of greatest benefit were: sort, subtotals, totals, record selection, storage of queries, global updating and the ability to page break. The major deficiencies were: one level of hierarchy, excessive response time, software unreliability, difficult to add, delete and modify records, complicated error messages and the lack of ability to perform interfield comparisons. Missing features users required were: formatted screens, interfield comparions, interfield arithmetic, multiple file access, security and data integrity. The survey team recommended Kennedy Space Center move forward to state-of-the-art software, a Data Base Management System which is thoroughly tested and easy to implement and use.

  9. Measurement of Visual Reaction Times Using Hand-held Mobile Devices

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.; Arsintescu, Lucia; Flynn-Evans, Erin

    2015-01-01

    Modern mobile devices provide a convenient platform for collecting research data in the field. But,because the working of these devices is often cloaked behind multiple layers of proprietary system software, it can bedifficult to assess the accuracy of the data they produce, particularly in the case of timing. We have been collecting datain a simple visual reaction time experiment, as part of a fatigue testing protocol known as the Psychomotor Vigilance Test (PVT). In this protocol, subjects run a 5-minute block consisting of a sequence of trials in which a visual stimulus appears after an unpredictable variable delay. The subject is required to tap the screen as soon as possible after the appearance of the stimulus. In order to validate the reaction times reported by our program, we had subjects perform the task while a high-speed video camera recorded both the display screen, and a side view of the finger (observed in a mirror). Simple image-processing methods were applied to determine the frames in which the stimulus appeared and disappeared, and in which the finger made and broke contact with the screen. The results demonstrate a systematic delay between the initial contact by the finger and the detection of the touch by the software, having a value of 80 +- 20 milliseconds.

  10. Remote Control and Monitoring of VLBI Experiments by Smartphones

    NASA Astrophysics Data System (ADS)

    Ruztort, C. H.; Hase, H.; Zapata, O.; Pedreros, F.

    2012-12-01

    For the remote control and monitoring of VLBI operations, we developed a software optimized for smartphones. This is a new tool based on a client-server architecture with a Web interface optimized for smartphone screens and cellphone networks. The server uses variables of the Field System and its station specific parameters stored in the shared memory. The client running on the smartphone by a Web interface analyzes and visualizes the current status of the radio telescope, receiver, schedule, and recorder. In addition, it allows commands to be sent remotely to the Field System computer and displays the log entries. The user has full access to the entire operation process, which is important in emergency cases. The software also integrates a webcam interface.

  11. Metadata management for high content screening in OMERO

    PubMed Central

    Li, Simon; Besson, Sébastien; Blackburn, Colin; Carroll, Mark; Ferguson, Richard K.; Flynn, Helen; Gillen, Kenneth; Leigh, Roger; Lindner, Dominik; Linkert, Melissa; Moore, William J.; Ramalingam, Balaji; Rozbicki, Emil; Rustici, Gabriella; Tarkowska, Aleksandra; Walczysko, Petr; Williams, Eleanor; Allan, Chris; Burel, Jean-Marie; Moore, Josh; Swedlow, Jason R.

    2016-01-01

    High content screening (HCS) experiments create a classic data management challenge—multiple, large sets of heterogeneous structured and unstructured data, that must be integrated and linked to produce a set of “final” results. These different data include images, reagents, protocols, analytic output, and phenotypes, all of which must be stored, linked and made accessible for users, scientists, collaborators and where appropriate the wider community. The OME Consortium has built several open source tools for managing, linking and sharing these different types of data. The OME Data Model is a metadata specification that supports the image data and metadata recorded in HCS experiments. Bio-Formats is a Java library that reads recorded image data and metadata and includes support for several HCS screening systems. OMERO is an enterprise data management application that integrates image data, experimental and analytic metadata and makes them accessible for visualization, mining, sharing and downstream analysis. We discuss how Bio-Formats and OMERO handle these different data types, and how they can be used to integrate, link and share HCS experiments in facilities and public data repositories. OME specifications and software are open source and are available at https://www.openmicroscopy.org. PMID:26476368

  12. Metadata management for high content screening in OMERO.

    PubMed

    Li, Simon; Besson, Sébastien; Blackburn, Colin; Carroll, Mark; Ferguson, Richard K; Flynn, Helen; Gillen, Kenneth; Leigh, Roger; Lindner, Dominik; Linkert, Melissa; Moore, William J; Ramalingam, Balaji; Rozbicki, Emil; Rustici, Gabriella; Tarkowska, Aleksandra; Walczysko, Petr; Williams, Eleanor; Allan, Chris; Burel, Jean-Marie; Moore, Josh; Swedlow, Jason R

    2016-03-01

    High content screening (HCS) experiments create a classic data management challenge-multiple, large sets of heterogeneous structured and unstructured data, that must be integrated and linked to produce a set of "final" results. These different data include images, reagents, protocols, analytic output, and phenotypes, all of which must be stored, linked and made accessible for users, scientists, collaborators and where appropriate the wider community. The OME Consortium has built several open source tools for managing, linking and sharing these different types of data. The OME Data Model is a metadata specification that supports the image data and metadata recorded in HCS experiments. Bio-Formats is a Java library that reads recorded image data and metadata and includes support for several HCS screening systems. OMERO is an enterprise data management application that integrates image data, experimental and analytic metadata and makes them accessible for visualization, mining, sharing and downstream analysis. We discuss how Bio-Formats and OMERO handle these different data types, and how they can be used to integrate, link and share HCS experiments in facilities and public data repositories. OME specifications and software are open source and are available at https://www.openmicroscopy.org. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Is routine alcohol screening and brief intervention feasible in a New Zealand primary care environment.

    PubMed

    Gifford, Heather; Paton, Sue; Cvitanovic, Lynley; McMenamin, John; Newton, Chloe

    2012-05-11

    To test the feasibility of a systemised ABC alcohol screening and brief intervention (SBI) approach in general practice in a New Zealand region. Data were collected on patients over 15 years who had their alcohol status recorded using the AUDIT tool. A concurrent independent process evaluation was conducted to assess effectiveness of ABC alcohol SBI related training and implementation of intervention. In an 8-month period, general practices in the Whanganui region documented alcohol consumption of 43% of their patients. Of the 43% of patients screened 24% were drinking contrary to ALAC's low risk drinking advice. Of these, 36% received brief advice or referral. Success of the approach can be attributed to the use of the Patient Dashboard reminder software and linked alcohol recording form. Other success factors included the use of a clinical champion and project leader, education and training, funding for extra GP and nurse assessment time and linking of the ABC alcohol SBI approach to existing services. Primary care in Whanganui has demonstrated the capacity to routinely query patient alcohol use and offer brief advice. If the approach was more widely adopted, there is considerable scope for general practice nationally to address potentially harmful patient alcohol use.

  14. Pilot Study of an Open-source Image Analysis Software for Automated Screening of Conventional Cervical Smears.

    PubMed

    Sanyal, Parikshit; Ganguli, Prosenjit; Barui, Sanghita; Deb, Prabal

    2018-01-01

    The Pap stained cervical smear is a screening tool for cervical cancer. Commercial systems are used for automated screening of liquid based cervical smears. However, there is no image analysis software used for conventional cervical smears. The aim of this study was to develop and test the diagnostic accuracy of a software for analysis of conventional smears. The software was developed using Python programming language and open source libraries. It was standardized with images from Bethesda Interobserver Reproducibility Project. One hundred and thirty images from smears which were reported Negative for Intraepithelial Lesion or Malignancy (NILM), and 45 images where some abnormality has been reported, were collected from the archives of the hospital. The software was then tested on the images. The software was able to segregate images based on overall nuclear: cytoplasmic ratio, coefficient of variation (CV) in nuclear size, nuclear membrane irregularity, and clustering. 68.88% of abnormal images were flagged by the software, as well as 19.23% of NILM images. The major difficulties faced were segmentation of overlapping cell clusters and separation of neutrophils. The software shows potential as a screening tool for conventional cervical smears; however, further refinement in technique is required.

  15. Data and animal management software for large-scale phenotype screening.

    PubMed

    Ching, Keith A; Cooke, Michael P; Tarantino, Lisa M; Lapp, Hilmar

    2006-04-01

    The mouse N-ethyl-N-nitrosourea (ENU) mutagenesis program at the Genomics Institute of the Novartis Research Foundation (GNF) uses MouseTRACS to analyze phenotype screens and manage animal husbandry. MouseTRACS is a Web-based laboratory informatics system that electronically records and organizes mouse colony operations, prints cage cards, tracks inventory, manages requests, and reports Institutional Animal Care and Use Committee (IACUC) protocol usage. For efficient phenotype screening, MouseTRACS identifies mutants, visualizes data, and maps mutations. It displays and integrates phenotype and genotype data using likelihood odds ratio (LOD) plots of genetic linkage between genotype and phenotype. More detailed mapping intervals show individual single nucleotide polymorphism (SNP) markers in the context of phenotype. In addition, dynamically generated pedigree diagrams and inventory reports linked to screening results summarize the inheritance pattern and the degree of penetrance. MouseTRACS displays screening data in tables and uses standard charts such as box plots, histograms, scatter plots, and customized charts looking at clustered mice or cross pedigree comparisons. In summary, MouseTRACS enables the efficient screening, analysis, and management of thousands of animals to find mutant mice and identify novel gene functions. MouseTRACS is available under an open source license at http://www.mousetracs.sourceforge.net.

  16. Automated Software System to Promote Anticoagulation and Reduce Stroke Risk: Cluster-Randomized Controlled Trial.

    PubMed

    Holt, Tim A; Dalton, Andrew; Marshall, Tom; Fay, Matthew; Qureshi, Nadeem; Kirkpatrick, Susan; Hislop, Jenny; Lasserson, Daniel; Kearley, Karen; Mollison, Jill; Yu, Ly-Mee; Hobbs, F D Richard; Fitzmaurice, David

    2017-03-01

    Oral anticoagulants (OAC) substantially reduce risk of stroke in atrial fibrillation, but uptake is suboptimal. Electronic health records enable automated identification of people at risk but not receiving treatment. We investigated the effectiveness of a software tool (AURAS-AF [Automated Risk Assessment for Stroke in Atrial Fibrillation]) designed to identify such individuals during routine care through a cluster-randomized trial. Screen reminders appeared each time the electronic health records of an eligible patient was accessed until a decision had been taken over OAC treatment. Where OAC was not started, clinicians were prompted to indicate a reason. Control practices continued usual care. The primary outcome was the proportion of eligible individuals receiving OAC at 6 months. Secondary outcomes included rates of cardiovascular events and reports of adverse effects of the software on clinical decision-making. Forty-seven practices were randomized. The mean proportion-prescribed OAC at 6 months was 66.3% (SD=9.3) in the intervention arm and 63.9% (9.5) in the control arm (adjusted difference 1.21% [95% confidence interval -0.72 to 3.13]). Incidence of recorded transient ischemic attack was higher in the intervention practices (median 10.0 versus 2.3 per 1000 patients with atrial fibrillation; P =0.027), but at 12 months, we found a lower incidence of both all cause stroke ( P =0.06) and hemorrhage ( P =0.054). No adverse effects of the software were reported. No significant change in OAC prescribing occurred. A greater rate of diagnosis of transient ischemic attack (possibly because of improved detection or overdiagnosis) was associated with a reduction (of borderline significance) in stroke and hemorrhage over 12 months. URL: http://www.isrctn.com. Unique Identifier: ISRCTN55722437. © 2017 American Heart Association, Inc.

  17. The Role and Design of Screen Images in Software Documentation.

    ERIC Educational Resources Information Center

    van der Meij, Hans

    2000-01-01

    Discussion of learning a new computer software program focuses on how to support the joint handling of a manual, input devices, and screen display. Describes a study that examined three design styles for manuals that included screen images to reduce split-attention problems and discusses theory versus practice and cognitive load theory.…

  18. Modification of infant hypothyroidism and phenylketonuria screening program using electronic tools.

    PubMed

    Taheri, Behjat; Haddadpoor, Asefeh; Mirkhalafzadeh, Mahmood; Mazroei, Fariba; Aghdak, Pezhman; Nasri, Mehran; Bahrami, Gholamreza

    2017-01-01

    Congenital hypothyroidism and phenylketonuria (PKU) are the most common cause for preventable mental retardation in infants worldwide. Timely diagnosis and treatment of these disorders can have lasting effects on the mental development of newborns. However, there are several problems at different stages of screening programs that along with imposing heavy costs can reduce the precision of the screening, increasing the chance of undiagnosed cases which in turn can have damaging consequences for the society. Therefore, given these problems and the importance of information systems in facilitating the management and improving the quality of health care the aim of this study was to improve the screening process of hypothyroidism and PKU in infants with the help of electronic resources. The current study is a qualitative, action research designed to improve the quality of screening, services, performance, implementation effectiveness, and management of hypothyroidism and PKU screening program in Isfahan province. To this end, web-based software was designed. Programming was carried out using Delphi.net software and used SQL Server 2008 for database management. Given the weaknesses, problems, and limitations of hypothyroidism and PKU screening program, and the importance of these diseases in a national scale, this study resulted in design of hypothyroidism and PKU screening software for infants in Isfahan province. The inputs and outputs of the software were designed in three levels including Health Care Centers in charge of the screening program, provincial reference lab, and health and treatment network of Isfahan province. Immediate registration of sample data at the time and location of sampling, providing the provincial reference Laboratory and Health Centers of different eparchies with the ability to instantly observe, monitor, and follow-up on the samples at any moment, online verification of samples by reference lab, creating a daily schedule for reference lab, and receiving of the results from analysis equipment; and entering the results into the database without the need for user input are among the features of this software. The implementation of hypothyroidism screening software led to an increase in the quality and efficiency of the screening program; minimized the risk of human error in the process and solved many of the previous limitations of the screening program which were the main goals for implementation of this software. The implementation of this software also resulted in improvement in precision and quality of services provided for these two diseases and better accuracy and precision for data inputs by providing the possibility of entering the sample data at the place and time of sampling which then resulted in the possibility of management based on precise data and also helped develop a comprehensive database and improved the satisfaction of service recipients.

  19. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  20. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  1. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  2. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  3. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  4. Quick and Easy: Use Screen Capture Software to Train and Communicate

    ERIC Educational Resources Information Center

    Schuster, Ellen

    2011-01-01

    Screen capture (screen cast) software can be used to develop short videos for training purposes. Developing videos is quick and easy. This article describes how these videos are used as tools to reinforce face-to-face and interactive TV curriculum training in a nutrition education program. Advantages of developing these videos are shared.…

  5. MOLA: a bootable, self-configuring system for virtual screening using AutoDock4/Vina on computer clusters.

    PubMed

    Abreu, Rui Mv; Froufe, Hugo Jc; Queiroz, Maria João Rp; Ferreira, Isabel Cfr

    2010-10-28

    Virtual screening of small molecules using molecular docking has become an important tool in drug discovery. However, large scale virtual screening is time demanding and usually requires dedicated computer clusters. There are a number of software tools that perform virtual screening using AutoDock4 but they require access to dedicated Linux computer clusters. Also no software is available for performing virtual screening with Vina using computer clusters. In this paper we present MOLA, an easy-to-use graphical user interface tool that automates parallel virtual screening using AutoDock4 and/or Vina in bootable non-dedicated computer clusters. MOLA automates several tasks including: ligand preparation, parallel AutoDock4/Vina jobs distribution and result analysis. When the virtual screening project finishes, an open-office spreadsheet file opens with the ligands ranked by binding energy and distance to the active site. All results files can automatically be recorded on an USB-flash drive or on the hard-disk drive using VirtualBox. MOLA works inside a customized Live CD GNU/Linux operating system, developed by us, that bypass the original operating system installed on the computers used in the cluster. This operating system boots from a CD on the master node and then clusters other computers as slave nodes via ethernet connections. MOLA is an ideal virtual screening tool for non-experienced users, with a limited number of multi-platform heterogeneous computers available and no access to dedicated Linux computer clusters. When a virtual screening project finishes, the computers can just be restarted to their original operating system. The originality of MOLA lies on the fact that, any platform-independent computer available can he added to the cluster, without ever using the computer hard-disk drive and without interfering with the installed operating system. With a cluster of 10 processors, and a potential maximum speed-up of 10x, the parallel algorithm of MOLA performed with a speed-up of 8,64× using AutoDock4 and 8,60× using Vina.

  6. [A personal computer-based system for online monitoring of neurologic intensive care patients].

    PubMed

    Stoll, M; Hamann, G; Jost, V; Schimrigk, K

    1992-03-01

    In the management of neurological intensive care patients with an intracranial space-consuming process the measurement and recording of intracranial pressure together with arterial blood pressure is of special interest. These parameters can be used to monitor the treatment of brain edema and hypertension. Intracranial pressure measurement is also important in the diagnosis of the various subtypes of hydrocephalus. Not only the absolute figures, but also the recognition of specific pressure-patterns is of particular clinical and scientific interest. This new, easily installed and inexpensive system comprises a PC and a conventional monitor, which are connected by an AD-conversion card. Our software, specially developed for this system demonstrates, stores and prints the online-course and the trend of the measurements. In addition it is also possible to view the online-course of conspicuous parts of the trend curve retrospectively and to use these values for statistical analyses. Object-orientated software development techniques were used for flexible graphic output on the screen, printer or to a file. Though developed for this specific purpose, this system is also suitable for recording continuous, longer-term measurements in general.

  7. A service for the application of data quality information to NASA earth science satellite records

    NASA Astrophysics Data System (ADS)

    Armstrong, E. M.; Xing, Z.; Fry, C.; Khalsa, S. J. S.; Huang, T.; Chen, G.; Chin, T. M.; Alarcon, C.

    2016-12-01

    A recurring demand in working with satellite-based earth science data records is the need to apply data quality information. Such quality information is often contained within the data files as an array of "flags", but can also be represented by more complex quality descriptions such as combinations of bit flags, or even other ancillary variables that can be applied as thresholds to the geophysical variable of interest. For example, with Level 2 granules from the Group for High Resolution Sea Surface Temperature (GHRSST) project up to 6 independent variables could be used to screen the sea surface temperature measurements on a pixel-by-pixel basis. Quality screening of Level 3 data from the Soil Moisture Active Passive (SMAP) instrument can be become even more complex, involving 161 unique bit states or conditions a user can screen for. The application of quality information is often a laborious process for the user until they understand the implications of all the flags and bit conditions, and requires iterative approaches using custom software. The Virtual Quality Screening Service, a NASA ACCESS project, is addressing these issues and concerns. The project has developed an infrastructure to expose, apply, and extract quality screening information building off known and proven NASA components for data extraction and subset-by-value, data discovery, and exposure to the user of granule-based quality information. Further sharing of results through well-defined URLs and web service specifications has also been implemented. The presentation will focus on overall description of the technologies and informatics principals employed by the project. Examples of implementations of the end-to-end web service for quality screening with GHRSST and SMAP granules will be demonstrated.

  8. Eddy-current inspection of shuttle heat exchanger tube welds

    NASA Technical Reports Server (NTRS)

    Dodd, Casius V.; Scott, G. W.; Chitwood, L. D.

    1990-01-01

    The goal of this project was to develop the system necessary to demonstrate in the laboratory that an eddy current system can inspect the tubes and welds described, screening for the existence of flaws equal in size to, or larger than, the target flaw. The laboratory system was to include the probe necessary to traverse the tubing, the electronics to drive (i.e., electrically excite) the probe and receive and process signals from it, a data display, data recording, and playback devices, and microprocessor software or firmware necessary to operate the system.

  9. EPICS-based control and data acquisition for the APS slope profiler (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sullivan, Joseph; Assoufid, Lahsen; Qian, Jun; Jemian, Peter R.; Mooney, Tim; Rivers, Mark L.; Goetze, Kurt; Sluiter, Ronald L.; Lang, Keenan

    2016-09-01

    The motion control, data acquisition and analysis system for APS Slope Measuring Profiler was implemented using the Experimental Physics and Industrial Control System (EPICS). EPICS was designed as a framework with software tools and applications that provide a software infrastructure used in building distributed control systems to operate devices such as particle accelerators, large experiments and major telescopes. EPICS was chosen to implement the APS Slope Measuring Profiler because it is also applicable to single purpose systems. The control and data handling capability available in the EPICS framework provides the basic functionality needed for high precision X-ray mirror measurement. Those built in capabilities include hardware integration of high-performance motion control systems (3-axis gantry and tip-tilt stages), mirror measurement devices (autocollimator, laser spot camera) and temperature sensors. Scanning the mirror and taking measurements was accomplished with an EPICS feature (the sscan record) which synchronizes motor positioning with measurement triggers and data storage. Various mirror scanning modes were automatically configured using EPICS built-in scripting. EPICS tools also provide low-level image processing (areaDetector). Operation screens were created using EPICS-aware GUI screen development tools.

  10. Does handwriting on a tablet screen affect students' graphomotor execution? A comparison between Grades Two and Nine.

    PubMed

    Alamargot, Denis; Morin, Marie-France

    2015-12-01

    We sought to ascertain how handwriting with a plastic-tipped pen on the screen of a digital tablet affects graphomotor execution in students, compared with handwriting on paper with a ballpoint pen. We predicted that the modification to propriokinesthetic feedback induced by the screen/plastic tip combination would differently disturb younger and older students, who rely on perceptual feedback either to form letters (former) or to adjust movement execution (latter). Twenty-eight students from Grades Two and Nine were asked to handwrite the alphabet and their names and surnames under the two conditions. Kinematics were recorded using the tablet, controlled by Eye and Pen software. Results showed that handwriting on the tablet surface with a plastic-tipped pen primarily affected pen pauses in the second graders and pen movements in the ninth graders, suggesting a disturbance in segment trajectory calculation in the younger participants and reduced control of muscular adjustment in the older children. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Remote Internet access to advanced analytical facilities: a new approach with Web-based services.

    PubMed

    Sherry, N; Qin, J; Fuller, M Suominen; Xie, Y; Mola, O; Bauer, M; McIntyre, N S; Maxwell, D; Liu, D; Matias, E; Armstrong, C

    2012-09-04

    Over the past decade, the increasing availability of the World Wide Web has held out the possibility that the efficiency of scientific measurements could be enhanced in cases where experiments were being conducted at distant facilities. Examples of early successes have included X-ray diffraction (XRD) experimental measurements of protein crystal structures at synchrotrons and access to scanning electron microscopy (SEM) and NMR facilities by users from institutions that do not possess such advanced capabilities. Experimental control, visual contact, and receipt of results has used some form of X forwarding and/or VNC (virtual network computing) software that transfers the screen image of a server at the experimental site to that of the users' home site. A more recent development is a web services platform called Science Studio that provides teams of scientists with secure links to experiments at one or more advanced research facilities. The software provides a widely distributed team with a set of controls and screens to operate, observe, and record essential parts of the experiment. As well, Science Studio provides high speed network access to computing resources to process the large data sets that are often involved in complex experiments. The simple web browser and the rapid transfer of experimental data to a processing site allow efficient use of the facility and assist decision making during the acquisition of the experimental results. The software provides users with a comprehensive overview and record of all parts of the experimental process. A prototype network is described involving X-ray beamlines at two different synchrotrons and an SEM facility. An online parallel processing facility has been developed that analyzes the data in near-real time using stream processing. Science Studio and can be expanded to include many other analytical applications, providing teams of users with rapid access to processed results along with the means for detailed discussion of their significance.

  12. [Development of integrated support software for clinical nutrition].

    PubMed

    Siquier Homar, Pedro; Pinteño Blanco, Manel; Calleja Hernández, Miguel Ángel; Fernández Cortés, Francisco; Martínez Sotelo, Jesús

    2015-09-01

    to develop an integrated computer software application for specialized nutritional support, integrated in the electronic clinical record, which detects automatically and early those undernourished patients or at risk of developing undernourishment, determining points of opportunity for improvement and evaluation of the results. the quality standards published by the Nutrition Work Group of the Spanish Society of Hospital Pharmacy (SEFH) and the recommendations by the Pharmacy Group of the Spanish Society of Parenteral and Enteral Nutrition (SENPE) have been taken into account. According to these quality standards, the nutritional support has to include the following healthcare stages or sub-processes: nutritional screening, nutritional assessment, plan for nutritional care, prescription, preparation and administration. this software allows to conduct, in an automated way, a specific nutritional assessment for those patients with nutritional risk, implementing, if necessary, a nutritional treatment plan, conducting follow-up and traceability of outcomes derived from the implementation of improvement actions, and quantifying to what extent our practice is close to the established standard. this software allows to standardize the specialized nutritional support from a multidisciplinary point of view, introducing the concept of quality control per processes, and including patient as the main customer. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  13. Positive Emotions Associated with "Counter-Strike" Game Playing.

    PubMed

    Shin, Mirim; Heard, Rob; Suo, Chao; Chow, Chin Moi

    2012-10-01

    Digital game playing engages people for long periods of time. The pleasure offered by digital games may explain the players' consumption of this activity. Games may elicit both positive and negative emotions, which can be measured by encephalography (EEG). The EEG alpha asymmetry index (AI) is different in positive and negative emotions and so may be used to distinguish positive from negative emotions that occur during gaming. We hypothesized that the "Counter-Strike" (CS) game (Valve Software, Bellevue, WA) is pleasurable and demonstrable with a positive EEG AI. Twelve male participants ages 18-30 years underwent EEG recordings continuously during and postgame. EEG was also recorded pregame for control conditions of baseline (sitting on a chair staring at a blank wall), movement (moving fingers on the computer keyboard with a blank screen), sound (listening to the sound of the CS game with a blank screen), and screen (watching the CS game without playing). Self-ratings of emotional responses were completed at pre-, during, and postgame. A significant decrease in the EEG AI was observed under the screen condition compared with baseline, whereas an increase was observed postgame compared with the screen condition. The participants demonstrated a positive EEG AI following the "shoot" events (shoot opponents) and negative emotions after the "being shot" events. Subjective ratings of emotional response indicated happiness during and postgame, but anger and arousal were reported only during the game. The overall results are consistent with the hypothesis that predominantly positive emotional reactions are elicited from playing the CS game and concur with positive subjective ratings of happiness. Future studies may explore the relationship of game pleasure and obsessive game play.

  14. Selection of the optimum font type and size interface for on screen continuous reading by young adults: an ergonomic approach.

    PubMed

    Banerjee, Jayeeta; Bhattacharyya, Moushum

    2011-12-01

    There is a rapid shifting of media: from printed paper to computer screens. This transition is modifying the process of how we read and understand text. The efficiency of reading is dependent on how ergonomically the visual information is presented. Font types and size characteristics have been shown to affect reading. A detailed investigation of the effect of the font type and size on reading on computer screens has been carried out by using subjective, objective and physiological evaluation methods on young adults. A group of young participants volunteered for this study. Two types of fonts were used: Serif fonts (Times New Roman, Georgia, Courier New) and Sans serif fonts (Verdana, Arial, Tahoma). All fonts were presented in 10, 12 and 14 point sizes. This study used a 6 X 3 (font type X size) design matrix. Participants read 18 passages of approximately the same length and reading level on a computer monitor. Reading time, ranking and overall mental workload were measured. Eye movements were recorded by a binocular eye movement recorder. Reading time was minimum for Courier New l4 point. The participants' ranking was highest and mental workload was least for Verdana 14 point. The pupil diameter, fixation duration and gaze duration were least for Courier New 14 point. The present study recommends using 14 point sized fonts for reading on computer screen. Courier New is recommended for fast reading while for on screen presentation Verdana is recommended. The outcome of this study will help as a guideline to all the PC users, software developers, web page designers and computer industry as a whole.

  15. ENCoRE: an efficient software for CRISPR screens identifies new players in extrinsic apoptosis.

    PubMed

    Trümbach, Dietrich; Pfeiffer, Susanne; Poppe, Manuel; Scherb, Hagen; Doll, Sebastian; Wurst, Wolfgang; Schick, Joel A

    2017-11-25

    As CRISPR/Cas9 mediated screens with pooled guide libraries in somatic cells become increasingly established, an unmet need for rapid and accurate companion informatics tools has emerged. We have developed a lightweight and efficient software to easily manipulate large raw next generation sequencing datasets derived from such screens into informative relational context with graphical support. The advantages of the software entitled ENCoRE (Easy NGS-to-Gene CRISPR REsults) include a simple graphical workflow, platform independence, local and fast multithreaded processing, data pre-processing and gene mapping with custom library import. We demonstrate the capabilities of ENCoRE to interrogate results from a pooled CRISPR cellular viability screen following Tumor Necrosis Factor-alpha challenge. The results not only identified stereotypical players in extrinsic apoptotic signaling but two as yet uncharacterized members of the extrinsic apoptotic cascade, Smg7 and Ces2a. We further validated and characterized cell lines containing mutations in these genes against a panel of cell death stimuli and involvement in p53 signaling. In summary, this software enables bench scientists with sensitive data or without access to informatic cores to rapidly interpret results from large scale experiments resulting from pooled CRISPR/Cas9 library screens.

  16. Screen Miniatures as Icons for Backward Navigation in Content-Based Software.

    ERIC Educational Resources Information Center

    Boling, Elizabeth; Ma, Guoping; Tao, Chia-Wen; Askun, Cengiz; Green, Tim; Frick, Theodore; Schaumburg, Heike

    Users of content-based software programs, including hypertexts and instructional multimedia, rely on the navigation functions provided by the designers of those program. Typical navigation schemes use abstract symbols (arrows) to label basic navigational functions like moving forward or backward through screen displays. In a previous study, the…

  17. Flux Tower Eddy Covariance and Meteorological Measurements for Barrow, Alaska: 2012-2016

    DOE Data Explorer

    Dengel, Sigrid; Torn, Margaret; Billesbach, David

    2017-08-24

    The dataset contains half-hourly eddy covariance flux measurements and determinations, companion meteorological measurements, and ancillary data from the flux tower (US-NGB) on the Barrow Environmental Observatory at Barrow (Utqiagvik), Alaska for the period 2012 through 2016. Data have been processed using EddyPro software and screened by the contributor. The flux tower sits in an Arctic coastal tundra ecosystem. This dataset updates a previous dataset by reprocessing a longer period of record in the same manner. Related dataset "Eddy-Covariance and auxiliary measurements, NGEE-Barrow, 2012-2013" DOI:10.5440/1124200.

  18. A Process for Evaluating Student Records Management Software. ERIC/AE Digest.

    ERIC Educational Resources Information Center

    Vecchioli, Lisa

    This digest provides practical advice on evaluating software for managing student records. An evaluation of record-keeping software should start with a process to identify all of the individual needs the software produce must meet in order to be considered for purchase. The first step toward establishing an administrative computing system is…

  19. Records Inventory Data Collection Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Brian A.

    1995-03-01

    DATALINK was created to provide an easy to use data collection program for records management software products. It provides several useful tools for capturing and validating record index data in the field. It also allows users to easily create a comma delimited, ASCII text file for data export into most records management software products.

  20. Mining collections of compounds with Screening Assistant 2

    PubMed Central

    2012-01-01

    Background High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. Results We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Conclusions Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/. PMID:23327565

  1. Mining collections of compounds with Screening Assistant 2.

    PubMed

    Guilloux, Vincent Le; Arrault, Alban; Colliandre, Lionel; Bourg, Stéphane; Vayer, Philippe; Morin-Allory, Luc

    2012-08-31

    High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/.

  2. Use of a secure Internet Web site for collaborative medical research.

    PubMed

    Marshall, W W; Haley, R W

    2000-10-11

    Researchers who collaborate on clinical research studies from diffuse locations need a convenient, inexpensive, secure way to record and manage data. The Internet, with its World Wide Web, provides a vast network that enables researchers with diverse types of computers and operating systems anywhere in the world to log data through a common interface. Development of a Web site for scientific data collection can be organized into 10 steps, including planning the scientific database, choosing a database management software system, setting up database tables for each collaborator's variables, developing the Web site's screen layout, choosing a middleware software system to tie the database software to the Web site interface, embedding data editing and calculation routines, setting up the database on the central server computer, obtaining a unique Internet address and name for the Web site, applying security measures to the site, and training staff who enter data. Ensuring the security of an Internet database requires limiting the number of people who have access to the server, setting up the server on a stand-alone computer, requiring user-name and password authentication for server and Web site access, installing a firewall computer to prevent break-ins and block bogus information from reaching the server, verifying the identity of the server and client computers with certification from a certificate authority, encrypting information sent between server and client computers to avoid eavesdropping, establishing audit trails to record all accesses into the Web site, and educating Web site users about security techniques. When these measures are carefully undertaken, in our experience, information for scientific studies can be collected and maintained on Internet databases more efficiently and securely than through conventional systems of paper records protected by filing cabinets and locked doors. JAMA. 2000;284:1843-1849.

  3. Application of Plagiarism Screening Software in the Chemical Engineering Curriculum

    ERIC Educational Resources Information Center

    Cooper, Matthew E.; Bullard, Lisa G.

    2014-01-01

    Plagiarism is an area of increasing concern for written ChE assignments, such as laboratory and design reports, due to ease of access to text and other materials via the internet. This study examines the application of plagiarism screening software to four courses in a university chemical engineering curriculum. The effectiveness of plagiarism…

  4. DATALINK. Records Inventory Data Collection Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, B.

    1995-03-01

    DATALINK was created to provide an easy to use data collection program for records management software products. It provides several useful tools for capturing and validating record index data in the field. It also allows users to easily create a comma delimited, ASCII text file for data export into most records management software products.

  5. 78 FR 21314 - Medicare and State Health Care Programs: Fraud and Abuse; Electronic Health Records Safe Harbor...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... health records software or information technology and training services. The final rule for this safe... health records software or information technology and training services. In the same issue of the Federal..., licenses, and intellectual property related to electronic health records software; connectivity services...

  6. “Diagnosis by Behavioral Observation” Home-Videosomnography – A Rigorous Ethnographic Approach to Sleep of Children with Neurodevelopmental Conditions

    PubMed Central

    Ipsiroglu, Osman S.; Hung, Yi-Hsuan Amy; Chan, Forson; Ross, Michelle L.; Veer, Dorothee; Soo, Sonja; Ho, Gloria; Berger, Mai; McAllister, Graham; Garn, Heinrich; Kloesch, Gerhard; Barbosa, Adriano Vilela; Stockler, Sylvia; McKellin, William; Vatikiotis-Bateson, Eric

    2015-01-01

    Introduction: Advanced video technology is available for sleep-laboratories. However, low-cost equipment for screening in the home setting has not been identified and tested, nor has a methodology for analysis of video recordings been suggested. Methods: We investigated different combinations of hardware/software for home-videosomnography (HVS) and established a process for qualitative and quantitative analysis of HVS-recordings. A case vignette (HVS analysis for a 5.5-year-old girl with major insomnia and several co-morbidities) demonstrates how methodological considerations were addressed and how HVS added value to clinical assessment. Results: We suggest an “ideal set of hardware/software” that is reliable, affordable (∼$500) and portable (=2.8 kg) to conduct non-invasive HVS, which allows time-lapse analyses. The equipment consists of a net-book, a camera with infrared optics, and a video capture device. (1) We present an HVS-analysis protocol consisting of three steps of analysis at varying replay speeds: (a) basic overview and classification at 16× normal speed; (b) second viewing and detailed descriptions at 4–8× normal speed, and (c) viewing, listening, and in-depth descriptions at real-time speed. (2) We also present a custom software program that facilitates video analysis and note-taking (Annotator©), and Optical Flow software that automatically quantifies movement for internal quality control of the HVS-recording. The case vignette demonstrates how the HVS-recordings revealed the dimension of insomnia caused by restless legs syndrome, and illustrated the cascade of symptoms, challenging behaviors, and resulting medications. Conclusion: The strategy of using HVS, although requiring validation and reliability testing, opens the floor for a new “observational sleep medicine,” which has been useful in describing discomfort-related behavioral movement patterns in patients with communication difficulties presenting with challenging/disruptive sleep/wake behaviors. PMID:25852578

  7. 360° Film Brings Bombed Church to Life

    NASA Astrophysics Data System (ADS)

    Kwiatek, K.

    2011-09-01

    This paper explores how a computer-generated reconstruction of a church can be adapted to create a panoramic film that is presented in a panoramic viewer and also on a wrap-around projection system. It focuses on the fundamental principles of creating 360º films, not only in 3D modelling software, but also presents how to record 360º video using panoramic cameras inside the heritage site. These issues are explored in a case study of Charles Church in Plymouth, UK that was bombed in 1941 and has never been rebuilt. The generation of a 3D model of the bombed church started from the creation of five spherical panoramas and through the use of Autodesk ImageModeler software. The processed files were imported and merged together in Autodesk 3ds Max where a visualisation of the ruin was produced. A number of historical images were found and this collection enabled the process of a virtual reconstruction of the site. The aspect of merging two still or two video panoramas (one from 3D modelling software, the other one recorded on the site) from the same locations or with the same trajectories is also discussed. The prototype of 360º non-linear film tells a narrative of a wartime wedding that occurred in this church. The film was presented on two 360º screens where members of the audience could make decisions on whether to continue the ceremony or whether to run away when the bombing of the church starts. 3D modelling software made this possible to render a number of different alternati ves (360º images and 360º video). Immersive environments empower the visitor to imagine the building before it was destroyed.

  8. [Evaluation and impact on the use of information and communication technology in the clinical management and agreed shared monitoring of pressure ulcers].

    PubMed

    Bueno Yáñez, Olga; Rodríguez Arrieta, Jimena; Bagüés Bafaluy, Miren I; Calvo Aguirre, Juan José

    2015-01-01

    Tackling the huge problem of Pressure Ulcers (PU), involves looking for new recording methods and strategies, as well as the standardization of the assessment and intervention criteria. In this context, a specific software application for PU management has been developed and was used for assessing its acceptability, usefulness and applicability by professional nurses from three residential homes for the elderly over a period of one year. A software application is designed and evaluated. This software application allows health professionals to: Manage and monitor PUs.; to determine the risk of PUs; and perform a nutritional status screen, based on a comprehensive data collection, processing and interpretation. It also allows health professionals to exchange data between themselves and at different care levels, which could provide a new approach based on the use of ICT as a tool for an agreement to shared care. This approach has an important journey ahead in terms of its assessment, to which we attempt to contribute through this article. Three centres and 69 residents are taking part in this project. During these processes, 27 nutritional status screens and 22 PU risk assessments, as well as the monitoring of 230 PUs have been performed. Nurses professionals think that the system is useful, easy to use, and perceive that it improves patient monitoring, but not relationship between professionals. Moreover, they would like to makethe web a more powerful part of the application and to speed up the procedures. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  9. Captivating Open University Students with Online Literature Search Tutorials Created Using Screen Capture Software

    ERIC Educational Resources Information Center

    Wales, Tim; Robertson, Penny

    2008-01-01

    Purpose: The aim of this paper is to share the experiences and challenges faced by the Open University Library (OUL) in using screen capture software to develop online literature search tutorials. Design/methodology/approach: A summary of information literacy support at the OUL is provided as background information to explain the decision to…

  10. Exploring the feasibility of smart phone microphone for measurement of acoustic voice parameters and voice pathology screening.

    PubMed

    Uloza, Virgilijus; Padervinskis, Evaldas; Vegiene, Aurelija; Pribuisiene, Ruta; Saferis, Viktoras; Vaiciukynas, Evaldas; Gelzinis, Adas; Verikas, Antanas

    2015-11-01

    The objective of this study is to evaluate the reliability of acoustic voice parameters obtained using smart phone (SP) microphones and investigate the utility of use of SP voice recordings for voice screening. Voice samples of sustained vowel/a/obtained from 118 subjects (34 normal and 84 pathological voices) were recorded simultaneously through two microphones: oral AKG Perception 220 microphone and SP Samsung Galaxy Note3 microphone. Acoustic voice signal data were measured for fundamental frequency, jitter and shimmer, normalized noise energy (NNE), signal to noise ratio and harmonic to noise ratio using Dr. Speech software. Discriminant analysis-based Correct Classification Rate (CCR) and Random Forest Classifier (RFC) based Equal Error Rate (EER) were used to evaluate the feasibility of acoustic voice parameters classifying normal and pathological voice classes. Lithuanian version of Glottal Function Index (LT_GFI) questionnaire was utilized for self-assessment of the severity of voice disorder. The correlations of acoustic voice parameters obtained with two types of microphones were statistically significant and strong (r = 0.73-1.0) for the entire measurements. When classifying into normal/pathological voice classes, the Oral-NNE revealed the CCR of 73.7% and the pair of SP-NNE and SP-shimmer parameters revealed CCR of 79.5%. However, fusion of the results obtained from SP voice recordings and GFI data provided the CCR of 84.60% and RFC revealed the EER of 7.9%, respectively. In conclusion, measurements of acoustic voice parameters using SP microphone were shown to be reliable in clinical settings demonstrating high CCR and low EER when distinguishing normal and pathological voice classes, and validated the suitability of the SP microphone signal for the task of automatic voice analysis and screening.

  11. Pilot study on the use of data mining to identify cochlear implant candidates.

    PubMed

    Grisel, Jedidiah J; Schafer, Erin; Lam, Anne; Griffin, Terry

    2018-05-01

    The goal of this pilot study was to determine the clinical utility of data-mining software that screens for cochlear implant (CI) candidacy. The Auditory Implant Initiative developed a software module that screens for CI candidates via integration with a software system (Noah 4) that serves as a depository for hearing test data. To identify candidates, patient audiograms from one practice were exported into the screening module. Candidates were tracked to determine if any eventually underwent implantation. After loading 4836 audiograms from the Noah 4 system, the screening module identified 558 potential CI candidates. After reviewing the data for the potential candidates, 117 were targeted and invited to an educational event. Following the event, a total of six candidates were evaluated, and two were implanted. This objective approach to identifying candidates has the potential to address the gross underutilization of CIs by removing any bias or lack of knowledge regarding the management of severe to profound sensorineural hearing loss with CIs. The screening module was an effective tool for identifying potential CI candidates at one ENT practice. On a larger scale, the screening module has the potential to impact thousands of CI candidates worldwide.

  12. Real-Time Monitoring of Scada Based Control System for Filling Process

    NASA Astrophysics Data System (ADS)

    Soe, Aung Kyaw; Myint, Aung Naing; Latt, Maung Maung; Theingi

    2008-10-01

    This paper is a design of real-time monitoring for filling system using Supervisory Control and Data Acquisition (SCADA). The monitoring of production process is described in real-time using Visual Basic.Net programming under Visual Studio 2005 software without SCADA software. The software integrators are programmed to get the required information for the configuration screens. Simulation of components is expressed on the computer screen using parallel port between computers and filling devices. The programs of real-time simulation for the filling process from the pure drinking water industry are provided.

  13. Video Screen Capture Basics

    ERIC Educational Resources Information Center

    Dunbar, Laura

    2014-01-01

    This article is an introduction to video screen capture. Basic information of two software programs, QuickTime for Mac and BlueBerry Flashback Express for PC, are also discussed. Practical applications for video screen capture are given.

  14. Graph Visualization for RDF Graphs with SPARQL-EndPoints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukumar, Sreenivas R; Bond, Nathaniel

    2014-07-11

    RDF graphs are hard to visualize as triples. This software module is a web interface that connects to a SPARQL endpoint and retrieves graph data that the user can explore interactively and seamlessly. The software written in python and JavaScript has been tested to work on screens as little as the smart phones to large screens such as EVEREST.

  15. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  16. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  17. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  18. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  19. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  20. DATALINK: Records inventory data collection software. User`s guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, B.A.

    1995-03-01

    DATALINK was created to provide an easy to use data collection program for records management software products. It provides several useful tools for capturing and validating record index data in the field. It also allows users to easily create a comma delimited, ASCII text file for data export into most records management software products. It runs on virtually any computer us MS-DOS.

  1. A usability evaluation of medical software at an expert conference setting.

    PubMed

    Bond, Raymond Robert; Finlay, Dewar D; Nugent, Chris D; Moore, George; Guldenring, Daniel

    2014-01-01

    A usability test was employed to evaluate two medical software applications at an expert conference setting. One software application is a medical diagnostic tool (electrocardiogram [ECG] viewer) and the other is a medical research tool (electrode misplacement simulator [EMS]). These novel applications have yet to be adopted by the healthcare domain, thus, (1) we wanted to determine the potential user acceptance of these applications and (2) we wanted to determine the feasibility of evaluating medical diagnostic and medical research software at a conference setting as opposed to the conventional laboratory setting. The medical diagnostic tool (ECG viewer) was evaluated using seven delegates and the medical research tool (EMS) was evaluated using 17 delegates that were recruited at the 2010 International Conference on Computing in Cardiology. Each delegate/participant was required to use the software and undertake a set of predefined tasks during the session breaks at the conference. User interactions with the software were recorded using screen-recording software. The 'think-aloud' protocol was also used to elicit verbal feedback from the participants whilst they attempted the pre-defined tasks. Before and after each session, participants completed a pre-test and a post-test questionnaire respectively. The average duration of a usability session at the conference was 34.69 min (SD=10.28). However, taking into account that 10 min was dedicated to the pre-test and post-test questionnaires, the average time dedication to user interaction of the medical software was 24.69 min (SD=10.28). Given we have shown that usability data can be collected at conferences, this paper details the advantages of conference-based usability studies over the laboratory-based approach. For example, given delegates gather at one geographical location, a conference-based usability evaluation facilitates recruitment of a convenient sample of international subject experts. This would otherwise be very expensive to arrange. A conference-based approach also allows for data to be collected over a few days as opposed to months by avoiding administration duties normally involved in laboratory based approach, e.g. mailing invitation letters as part of a recruitment campaign. Following analysis of the user video recordings, 41 (previously unknown) use errors were identified in the advanced ECG viewer and 29 were identified in the EMS application. All use errors were given a consensus severity rating from two independent usability experts. Out of a rating scale of 4 (where 1=cosmetic and 4=critical), the average severity rating for the ECG viewer was 2.24 (SD=1.09) and the average severity rating for the EMS application was 2.34 (SD=0.97). We were also able to extract task completion rates and times from the video recordings to determine the effectiveness of the software applications. For example, six out of seven tasks were completed by all participants when using both applications. This statistic alone suggests both applications already have a high degree of usability. As well as extracting data from the video recordings, we were also able to extract data from the questionnaires. Using a semantic differential scale (where 1=poor and 5=excellent), delegates highly rated the 'responsiveness', 'usefulness', 'learnability' and the 'look and feel' of both applications. This study has shown the potential user acceptance and user-friendliness of the novel EMS and the ECG viewer applications within the healthcare domain. It has also shown that both medical diagnostic software and medical research software can be evaluated for their usability at an expert conference setting. The primary advantage of a conference-based usability evaluation over a laboratory-based evaluation is the high concentration of experts at one location, which is convenient, less time consuming and less expensive. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. VisualEyes: a modular software system for oculomotor experimentation.

    PubMed

    Guo, Yi; Kim, Eun H; Kim, Eun; Alvarez, Tara; Alvarez, Tara L

    2011-03-25

    Eye movement studies have provided a strong foundation forming an understanding of how the brain acquires visual information in both the normal and dysfunctional brain.(1) However, development of a platform to stimulate and store eye movements can require substantial programming, time and costs. Many systems do not offer the flexibility to program numerous stimuli for a variety of experimental needs. However, the VisualEyes System has a flexible architecture, allowing the operator to choose any background and foreground stimulus, program one or two screens for tandem or opposing eye movements and stimulate the left and right eye independently. This system can significantly reduce the programming development time needed to conduct an oculomotor study. The VisualEyes System will be discussed in three parts: 1) the oculomotor recording device to acquire eye movement responses, 2) the VisualEyes software written in LabView, to generate an array of stimuli and store responses as text files and 3) offline data analysis. Eye movements can be recorded by several types of instrumentation such as: a limbus tracking system, a sclera search coil, or a video image system. Typical eye movement stimuli such as saccadic steps, vergent ramps and vergent steps with the corresponding responses will be shown. In this video report, we demonstrate the flexibility of a system to create numerous visual stimuli and record eye movements that can be utilized by basic scientists and clinicians to study healthy as well as clinical populations.

  3. An Innovative Multimedia Approach to Laboratory Safety

    NASA Technical Reports Server (NTRS)

    Anderson, M. B.; Constant, K. P.

    1996-01-01

    A new approach for teaching safe laboratory practices has been developed for materials science laboratories at Iowa State university. Students are required to complete a computerized safety tutorial and pass an exam before working in the laboratory. The safety tutorial includes sections on chemical, electrical, radiation, and high temperature safety. The tutorial makes use of a variety of interactions, including 'assembly' interactions where a student is asked to drag and drop items with the mouse (either labels or pictures) to an appropriate place on the screen (sometimes in a specific order). This is extremely useful for demonstrating safe lab practices and disaster scenarios. Built into the software is a record tracking scheme so that a professor can access a file that records which students have completed the tutorial and their scores on the exam. This paper will describe the development and assessment of the safety tutorials.

  4. A labview-based GUI for the measurement of otoacoustic emissions.

    PubMed

    Wu, Ye; McNamara, D M; Ziarani, A K

    2006-01-01

    This paper presents the outcome of a software development project aimed at creating a stand-alone user-friendly signal processing algorithm for the estimation of distortion product otoacoustic emission (OAE) signals. OAE testing is one of the most commonly used methods of first screening of newborns' hearing. Most of the currently available commercial devices rely upon averaging long strings of data and subsequent discrete Fourier analysis to estimate low level OAE signals from within the background noise in the presence of the strong stimuli. The main shortcoming of the presently employed technology is the need for long measurement time and its low noise immunity. The result of the software development project presented here is a graphical user interface (GUI) module that implements a recently introduced adaptive technique of OAE signal estimation. This software module is easy to use and is freely disseminated on the Internet for the use of the hearing research community. This GUI module allows loading of the a priori recorded OAE signals into the workspace, and provides the user with interactive instructions for the OAE signal estimation. Moreover, the user can generate simulated OAE signals to objectively evaluate the performance capability of the implemented signal processing technique.

  5. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  6. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  7. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  8. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  9. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  10. [Evaluation of a registration card for logging electrocardiographic records into standard personal computers].

    PubMed

    Pizzuti, A; Baralis, G; Bassignana, A; Antonielli, E; Di Leo, M

    1997-01-01

    The MS200 Cardioscope, from MRT Micro as., Norway, is a 12 channel ECG card to be directly inserted into a standard personal computer (PC). The standard ISA Bus compatible half length card comes with a set of 10 cables with electrodes and the software for recording, displaying and saving ECG signals. The system is supplied with DOS or Windows software. The goal of the present work was to evaluate the affordability and usability of the MS200 in a clinical setting. We tested the 1.5 DOS version of the software. In 30 patients with various cardiac diseases the ECG signal has been recorded with MS200 and with standard Hellige CardioSmart equipment. The saved ECGs were recalled and printed using an Epson Stylus 800 ink-jet printer. Two cardiologists reviewed the recordings for a looking at output quality, amplitude and speed precision, artifacts, etc. 1) Installation: the card has proven to be totally compatible with the hardware; no changes in default settings had to be made. 2) Usage: the screens are clear; the commands and menus are intuitive and easy to use. Due to the boot-strap and software loading procedures and, most important, off-line printing, the time needed to obtain a complete ECG printout has been longer than that of the reference machine. 3) Archiving and retrieval of ECG: the ECG curves can be saved in original or compressed form: selecting the latter, the noise and non-ECG information is filtered away and the space consumption on disk is reduced: on average, 20 Kb are needed for 10 seconds of signal. The MS200 can be run on a Local Area Network and is prepared for integrating with an existing informative system: we are currently testing the system in this scenery. 4) MS200 includes options for on-line diagnosis, a technology we have not tested in the present work. 5) The only setting allowed for printing full pages is letter size (A4): the quality of printouts is good, with a resolution of 180 DPI. In conclusion, the MS200 system seems reliable and safe. In the configuration we tested, it cannot substitute a dedicated ECG equipment: from this point of view, a smaller PCMCIA-type card with a battery-operated notebook PC will be more suitable for clinical uses. Nevertheless, the possibility to log and track ECG records, integrated into the department informative system, may provide a valuable tool for improving access to medical information.

  11. Automated Risk Assessment for Stroke in Atrial Fibrillation (AURAS-AF)--an automated software system to promote anticoagulation and reduce stroke risk: study protocol for a cluster randomised controlled trial.

    PubMed

    Holt, Tim A; Fitzmaurice, David A; Marshall, Tom; Fay, Matthew; Qureshi, Nadeem; Dalton, Andrew R H; Hobbs, F D Richard; Lasserson, Daniel S; Kearley, Karen; Hislop, Jenny; Jin, Jing

    2013-11-13

    Patients with atrial fibrillation (AF) are at significantly increased risk of stroke. Oral anticoagulants (OACs) substantially reduce this risk, with gains seen across the spectrum of baseline risk. Despite the benefit to patients, OAC prescribing remains suboptimal in the United Kingdom (UK). We will investigate whether an automated software system, operating within primary care electronic medical records, can improve the management of AF by identifying patients eligible for OAC therapy and increasing uptake of this treatment. We will conduct a cluster randomised controlled trial, involving general practices using the Egton Medical Information Systems (EMIS) Web clinical system. We will randomise practices to use an electronic software tool or to continue with usual care. The tool will a) produce (and continually refresh) a list of patients with AF who are eligible for OAC therapy--practices will invite these patients to discuss therapy at the start of the trial--and b) generate electronic screen reminders in the medical records of those eligible, appearing throughout the trial. The software will run for 6 months in 23 intervention practices. A total of 23 control practices will manage their AF register in line with the usual care offered. The primary outcome is change in proportion of eligible patients with AF who have been prescribed OAC therapy after six months. Secondary outcomes are incidence of stroke, transient ischaemic attack, other major thromboembolism, major haemorrhage and reports of inappropriate OAC prescribing in the data collection sample--those deemed eligible for OACs. We will conduct a process evaluation in parallel with the randomised trial. We will use qualitative methods to examine patient and practitioner views of the intervention and its impact on primary care practice, including its time implications. AURAS-AF will investigate whether a simple intervention, using electronic primary care records, can improve OAC uptake in a high risk group for stroke. Given previous concerns about safety, especially surrounding inappropriate prescribing, we will also examine whether electronic reminders safely impact care in this clinical area. http://ISRCTN 55722437.

  12. A diabetes dashboard and physician efficiency and accuracy in accessing data needed for high-quality diabetes care.

    PubMed

    Koopman, Richelle J; Kochendorfer, Karl M; Moore, Joi L; Mehr, David R; Wakefield, Douglas S; Yadamsuren, Borchuluun; Coberly, Jared S; Kruse, Robin L; Wakefield, Bonnie J; Belden, Jeffery L

    2011-01-01

    We compared use of a new diabetes dashboard screen with use of a conventional approach of viewing multiple electronic health record (EHR) screens to find data needed for ambulatory diabetes care. We performed a usability study, including a quantitative time study and qualitative analysis of information-seeking behaviors. While being recorded with Morae Recorder software and "think-aloud" interview methods, 10 primary care physicians first searched their EHR for 10 diabetes data elements using a conventional approach for a simulated patient, and then using a new diabetes dashboard for another. We measured time, number of mouse clicks, and accuracy. Two coders analyzed think-aloud and interview data using grounded theory methodology. The mean time needed to find all data elements was 5.5 minutes using the conventional approach vs 1.3 minutes using the diabetes dashboard (P <.001). Physicians correctly identified 94% of the data requested using the conventional method, vs 100% with the dashboard (P <.01). The mean number of mouse clicks was 60 for conventional searching vs 3 clicks with the diabetes dashboard (P <.001). A common theme was that in everyday practice, if physicians had to spend too much time searching for data, they would either continue without it or order a test again. Using a patient-specific diabetes dashboard improves both the efficiency and accuracy of acquiring data needed for high-quality diabetes care. Usability analysis tools can provide important insights into the value of optimizing physician use of health information technologies.

  13. SWToolbox: A surface-water tool-box for statistical analysis of streamflow time series

    USGS Publications Warehouse

    Kiang, Julie E.; Flynn, Kate; Zhai, Tong; Hummel, Paul; Granato, Gregory

    2018-03-07

    This report is a user guide for the low-flow analysis methods provided with version 1.0 of the Surface Water Toolbox (SWToolbox) computer program. The software combines functionality from two software programs—U.S. Geological Survey (USGS) SWSTAT and U.S. Environmental Protection Agency (EPA) DFLOW. Both of these programs have been used primarily for computation of critical low-flow statistics. The main analysis methods are the computation of hydrologic frequency statistics such as the 7-day minimum flow that occurs on average only once every 10 years (7Q10), computation of design flows including biologically based flows, and computation of flow-duration curves and duration hydrographs. Other annual, monthly, and seasonal statistics can also be computed. The interface facilitates retrieval of streamflow discharge data from the USGS National Water Information System and outputs text reports for a record of the analysis. Tools for graphing data and screening tests are available to assist the analyst in conducting the analysis.

  14. Development of an automated large-scale protein-crystallization and monitoring system for high-throughput protein-structure analyses.

    PubMed

    Hiraki, Masahiko; Kato, Ryuichi; Nagai, Minoru; Satoh, Tadashi; Hirano, Satoshi; Ihara, Kentaro; Kudo, Norio; Nagae, Masamichi; Kobayashi, Masanori; Inoue, Michio; Uejima, Tamami; Oda, Shunichiro; Chavas, Leonard M G; Akutsu, Masato; Yamada, Yusuke; Kawasaki, Masato; Matsugaki, Naohiro; Igarashi, Noriyuki; Suzuki, Mamoru; Wakatsuki, Soichi

    2006-09-01

    Protein crystallization remains one of the bottlenecks in crystallographic analysis of macromolecules. An automated large-scale protein-crystallization system named PXS has been developed consisting of the following subsystems, which proceed in parallel under unified control software: dispensing precipitants and protein solutions, sealing crystallization plates, carrying robot, incubators, observation system and image-storage server. A sitting-drop crystallization plate specialized for PXS has also been designed and developed. PXS can set up 7680 drops for vapour diffusion per hour, which includes time for replenishing supplies such as disposable tips and crystallization plates. Images of the crystallization drops are automatically recorded according to a preprogrammed schedule and can be viewed by users remotely using web-based browser software. A number of protein crystals were successfully produced and several protein structures could be determined directly from crystals grown by PXS. In other cases, X-ray quality crystals were obtained by further optimization by manual screening based on the conditions found by PXS.

  15. Screening_mgmt: a Python module for managing screening data.

    PubMed

    Helfenstein, Andreas; Tammela, Päivi

    2015-02-01

    High-throughput screening is an established technique in drug discovery and, as such, has also found its way into academia. High-throughput screening generates a considerable amount of data, which is why specific software is used for its analysis and management. The commercially available software packages are often beyond the financial limits of small-scale academic laboratories and, furthermore, lack the flexibility to fulfill certain user-specific requirements. We have developed a Python module, screening_mgmt, which is a lightweight tool for flexible data retrieval, analysis, and storage for different screening assays in one central database. The module reads custom-made analysis scripts and plotting instructions, and it offers a graphical user interface to import, modify, and display the data in a uniform manner. During the test phase, we used this module for the management of 10,000 data points of various origins. It has provided a practical, user-friendly tool for sharing and exchanging information between researchers. © 2014 Society for Laboratory Automation and Screening.

  16. Evaluation of nutritional care of hospitalized children in a tertiary pediatric hospital.

    PubMed

    De Longueville, Caroline; Robert, Martine; Debande, Marjorie; Podlubnai, Sylviane; Defourny, Sophie; Namane, Sid-Ali; Pace, Aude; Brans, Camille; Cayrol, Elodie; Goyens, Philippe; De Laet, Corinne

    2018-06-01

    Hospitalized children are at risk of malnutrition. The aim of the present study was to evaluate a clinical practice in a tertiary hospital. The nutritional team developed a specific software for screening of malnutrition and risk of malnutrition (Evalnut) that provides also recommendations for the nutritional management of the patient. The data recorded into this program and the tool itself were analyzed and optimizations are highlighted. A retrospective study analyzed the data collected in 2015 during 4931 consecutive hospitalizations (3984 children) at the University Children's Hospital Queen Fabiola. Pivot tables analysis (Excel) of the database of the screening tool was compared with the clinical practice of the dietitians. First data processing excluded records with abnormal or missing values. Impact of nutritional care analysis needs at least 2 evaluations and a positive patient's height trend. In case of height equality, only length of hospital stays less than 2 weeks were kept. This study highlighted inaccurate database records related to imperfections of the computer program, missing or erroneous measures and incomplete encoding. First analysis on 3219 valid hospitalizations showed statistical correlations. Prevalence of malnutrition on admission was 33%, split into 14,5% acute malnutrition, 15% chronic malnutrition and 3,5% mixed malnutrition. Overall, 30,3% of the children were categorized at risk of developing malnutrition during their stay. Positive impact of nutritional management on the resulting nutritional status was demonstrated on the second data selection (352 hospitalizations): WFH median (interquartile range) increased from 96,1% (87,1-106,4) on admission to 96,9% (89,1-106,1) (p < 0,01) on discharge. An optimization of the existing software was finally proposed. In our hospital, the dietitians are the most aware on the importance of nutritional assessment and management during hospitalization. Encouraging results are obtained. Inclusion of a nutritional program in the medical file is useful to raise interest amongst caregivers and is particularly valuable for the nutritional follow up of the patients by the nutrition team. Copyright © 2018 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  17. CycloPs: generating virtual libraries of cyclized and constrained peptides including nonnatural amino acids.

    PubMed

    Duffy, Fergal J; Verniere, Mélanie; Devocelle, Marc; Bernard, Elise; Shields, Denis C; Chubb, Anthony J

    2011-04-25

    We introduce CycloPs, software for the generation of virtual libraries of constrained peptides including natural and nonnatural commercially available amino acids. The software is written in the cross-platform Python programming language, and features include generating virtual libraries in one-dimensional SMILES and three-dimensional SDF formats, suitable for virtual screening. The stand-alone software is capable of filtering the virtual libraries using empirical measurements, including peptide synthesizability by standard peptide synthesis techniques, stability, and the druglike properties of the peptide. The software and accompanying Web interface is designed to enable the rapid generation of large, structurally diverse, synthesizable virtual libraries of constrained peptides quickly and conveniently, for use in virtual screening experiments. The stand-alone software, and the Web interface for evaluating these empirical properties of a single peptide, are available at http://bioware.ucd.ie .

  18. Touch Interaction with 3D Geographical Visualization on Web: Selected Technological and User Issues

    NASA Astrophysics Data System (ADS)

    Herman, L.; Stachoň, Z.; Stuchlík, R.; Hladík, J.; Kubíček, P.

    2016-10-01

    The use of both 3D visualization and devices with touch displays is increasing. In this paper, we focused on the Web technologies for 3D visualization of spatial data and its interaction via touch screen gestures. At the first stage, we compared the support of touch interaction in selected JavaScript libraries on different hardware (desktop PCs with touch screens, tablets, and smartphones) and software platforms. Afterward, we realized simple empiric test (within-subject design, 6 participants, 2 simple tasks, LCD touch monitor Acer and digital terrain models as stimuli) focusing on the ability of users to solve simple spatial tasks via touch screens. An in-house testing web tool was developed and used based on JavaScript, PHP, and X3DOM languages and Hammer.js libraries. The correctness of answers, speed of users' performances, used gestures, and a simple gesture metric was recorded and analysed. Preliminary results revealed that the pan gesture is most frequently used by test participants and it is also supported by the majority of 3D libraries. Possible gesture metrics and future developments including the interpersonal differences are discussed in the conclusion.

  19. Type 2 Diabetes Mellitus Screening and Risk Factors Using Decision Tree: Results of Data Mining.

    PubMed

    Habibi, Shafi; Ahmadi, Maryam; Alizadeh, Somayeh

    2015-03-18

    The aim of this study was to examine a predictive model using features related to the diabetes type 2 risk factors. The data were obtained from a database in a diabetes control system in Tabriz, Iran. The data included all people referred for diabetes screening between 2009 and 2011. The features considered as "Inputs" were: age, sex, systolic and diastolic blood pressure, family history of diabetes, and body mass index (BMI). Moreover, we used diagnosis as "Class". We applied the "Decision Tree" technique and "J48" algorithm in the WEKA (3.6.10 version) software to develop the model. After data preprocessing and preparation, we used 22,398 records for data mining. The model precision to identify patients was 0.717. The age factor was placed in the root node of the tree as a result of higher information gain. The ROC curve indicates the model function in identification of patients and those individuals who are healthy. The curve indicates high capability of the model, especially in identification of the healthy persons. We developed a model using the decision tree for screening T2DM which did not require laboratory tests for T2DM diagnosis.

  20. Office Computer Software: A Comprehensive Review of Software Programs.

    ERIC Educational Resources Information Center

    Secretary, 1992

    1992-01-01

    Describes types of software including system software, application software, spreadsheets, accounting software, graphics packages, desktop publishing software, database, desktop and personal information management software, project and records management software, groupware, and shareware. (JOW)

  1. High-throughput image analysis of tumor spheroids: a user-friendly software application to measure the size of spheroids automatically and accurately.

    PubMed

    Chen, Wenjin; Wong, Chung; Vosburgh, Evan; Levine, Arnold J; Foran, David J; Xu, Eugenia Y

    2014-07-08

    The increasing number of applications of three-dimensional (3D) tumor spheroids as an in vitro model for drug discovery requires their adaptation to large-scale screening formats in every step of a drug screen, including large-scale image analysis. Currently there is no ready-to-use and free image analysis software to meet this large-scale format. Most existing methods involve manually drawing the length and width of the imaged 3D spheroids, which is a tedious and time-consuming process. This study presents a high-throughput image analysis software application - SpheroidSizer, which measures the major and minor axial length of the imaged 3D tumor spheroids automatically and accurately; calculates the volume of each individual 3D tumor spheroid; then outputs the results in two different forms in spreadsheets for easy manipulations in the subsequent data analysis. The main advantage of this software is its powerful image analysis application that is adapted for large numbers of images. It provides high-throughput computation and quality-control workflow. The estimated time to process 1,000 images is about 15 min on a minimally configured laptop, or around 1 min on a multi-core performance workstation. The graphical user interface (GUI) is also designed for easy quality control, and users can manually override the computer results. The key method used in this software is adapted from the active contour algorithm, also known as Snakes, which is especially suitable for images with uneven illumination and noisy background that often plagues automated imaging processing in high-throughput screens. The complimentary "Manual Initialize" and "Hand Draw" tools provide the flexibility to SpheroidSizer in dealing with various types of spheroids and diverse quality images. This high-throughput image analysis software remarkably reduces labor and speeds up the analysis process. Implementing this software is beneficial for 3D tumor spheroids to become a routine in vitro model for drug screens in industry and academia.

  2. Splash: a software tool for stereotactic planning of recording chamber placement and electrode trajectories.

    PubMed

    Sperka, Daniel J; Ditterich, Jochen

    2011-01-01

    While computer-aided planning of human neurosurgeries is becoming more and more common, animal researchers still largely rely on paper atlases for planning their approach before implanting recording chambers to perform invasive recordings of neural activity, which makes this planning process tedious and error-prone. Here we present SPLASh (Stereotactic PLAnning Software), an interactive software tool for the stereotactic planning of recording chamber placement and electrode trajectories. SPLASh has been developed for monkey cortical recordings and relies on a combination of structural MRIs and electronic brain atlases. Since SPLASh is based on the neuroanatomy software Caret, it should also be possible to use it for other parts of the brain or other species for which Caret atlases are available. The tool allows the user to interactively evaluate different possible placements of recording chambers and to simulate electrode trajectories.

  3. Splash: A Software Tool for Stereotactic Planning of Recording Chamber Placement and Electrode Trajectories

    PubMed Central

    Sperka, Daniel J.; Ditterich, Jochen

    2011-01-01

    While computer-aided planning of human neurosurgeries is becoming more and more common, animal researchers still largely rely on paper atlases for planning their approach before implanting recording chambers to perform invasive recordings of neural activity, which makes this planning process tedious and error-prone. Here we present SPLASh (Stereotactic PLAnning Software), an interactive software tool for the stereotactic planning of recording chamber placement and electrode trajectories. SPLASh has been developed for monkey cortical recordings and relies on a combination of structural MRIs and electronic brain atlases. Since SPLASh is based on the neuroanatomy software Caret, it should also be possible to use it for other parts of the brain or other species for which Caret atlases are available. The tool allows the user to interactively evaluate different possible placements of recording chambers and to simulate electrode trajectories. PMID:21472085

  4. EDRMS for Academic Records Management: A Design Study in a Malaysian University

    ERIC Educational Resources Information Center

    Miah, Shah Jahan; Samsudin, Ahmad Zam Hariro

    2017-01-01

    Higher education institutes such as universities suffer from a range of issues in managing their academic records and relevant digital contents. Many universities nowadays use specific software applications for their effective mechanism in records management. The effective provision of enterprises records management (ERM) software for managing…

  5. PrimerSuite: A High-Throughput Web-Based Primer Design Program for Multiplex Bisulfite PCR.

    PubMed

    Lu, Jennifer; Johnston, Andrew; Berichon, Philippe; Ru, Ke-Lin; Korbie, Darren; Trau, Matt

    2017-01-24

    The analysis of DNA methylation at CpG dinucleotides has become a major research focus due to its regulatory role in numerous biological processes, but the requisite need for assays which amplify bisulfite-converted DNA represents a major bottleneck due to the unique design constraints imposed on bisulfite-PCR primers. Moreover, a review of the literature indicated no available software solutions which accommodated both high-throughput primer design, support for multiplex amplification assays, and primer-dimer prediction. In response, the tri-modular software package PrimerSuite was developed to support bisulfite multiplex PCR applications. This software was constructed to (i) design bisulfite primers against multiple regions simultaneously (PrimerSuite), (ii) screen for primer-primer dimerizing artefacts (PrimerDimer), and (iii) support multiplex PCR assays (PrimerPlex). Moreover, a major focus in the development of this software package was the emphasis on extensive empirical validation, and over 1300 unique primer pairs have been successfully designed and screened, with over 94% of them producing amplicons of the expected size, and an average mapping efficiency of 93% when screened using bisulfite multiplex resequencing. The potential use of the software in other bisulfite-based applications such as methylation-specific PCR is under consideration for future updates. This resource is freely available for use at PrimerSuite website (www.primer-suite.com).

  6. ‘If I feel something wrong, then I will get a mammogram’: understanding barriers and facilitators for mammography screening among Chilean women

    PubMed Central

    Püschel, Klaus; Thompson, Beti; Coronado, Gloria; Gonzalez, Karla; Rain, Carolina; Rivera, Soledad

    2010-01-01

    Background. Breast cancer is the leading cause of cancer among women in Chile and in many Latin American countries. Breast cancer screening is an effective strategy to reduce mortality, but it has a very low compliance among Chilean women. Objective. To understand barriers and facilitators for breast cancer screening in a group of Chilean women aged 50–70. Methods. Following the Predisposing, Enabling and Reinforcing (PRECEDE) framework, seven focus groups (N = 48 women) were conducted with women that have had diverse experiences with breast cancer and screening practices. Information was collected using field notes and audio and video recording. Following the grounded theory model, a sequential process of open, axial and selective coding was used for the information analysis. Atlas ti 5.5 software was used for coding and segmenting the data obtained from the interviews. Results. The presence of symptoms and/or the finding of lumps through breast self-examination (BSE) were the main predisposing factors for getting a mammogram. Secrecy, embarrassment and fatalism about breast cancer were significant cultural factors that influenced the decision to seek mammogram screening. Confidence in medical staff and dignity in the treatment at the clinic were important enabling factors. The main reinforcing factors for getting the test were a sense of fulfilment by doing something good for themselves and getting timely information about the results. Conclusions. Primary health care providers should use culturally appropriate strategies to better inform women about the importance of mammography screening and the limitations of BSE for preventing advanced breast cancer. PMID:19897514

  7. Software for improved field surveys of nesting marine turtles.

    PubMed

    Anastácio, R; Gonzalez, J M; Slater, K; Pereira, M J

    2017-09-07

    Field data are still recorded on paper in many worldwide beach surveys of nesting marine turtles. The data must be subsequently transferred into an electronic database, and this can introduce errors in the dataset. To minimize such errors, the "Turtles" software was developed and piloted to record field data by one software user accompanying one Tortuguero in Akumal beaches, Quintana Roo, Mexico, from June 1 st to July 31 st during the night patrols. Comparisons were made between exported data from the software with the paper forms entered into a database (henceforth traditional). Preliminary assessment indicated that the software user tended to record a greater amount of metrics (i.e., an average of 18.3 fields ± 5.4 sd vs. 8.6 fields ± 2.1 sd recorded by the traditional method). The traditional method introduce three types of "errors" into a dataset: missing values in relevant fields (40.1%), different answers for the same value (9.8%), and inconsistent data (0.9%). Only 5.8% of these (missing values) were found with the software methodology. Although only tested by a single user, the software may suggest increased efficacy and warrants further examination to accurately assess the merit of replacing traditional methods of data recording for beach monitoring programmes.

  8. The Software Design Document: More than a User's Manual.

    ERIC Educational Resources Information Center

    Bowers, Dennis

    1989-01-01

    Discusses the value of creating design documentation for computer software so that it may serve as a model for similar design efforts. Components of the software design document are described, including program flowcharts, graphic representation of screen displays, storyboards, and evaluation procedures. An example is given using HyperCard. (three…

  9. Improving the quality of EHR recording in primary care: a data quality feedback tool.

    PubMed

    van der Bij, Sjoukje; Khan, Nasra; Ten Veen, Petra; de Bakker, Dinny H; Verheij, Robert A

    2017-01-01

    Electronic health record (EHR) data are used to exchange information among health care providers. For this purpose, the quality of the data is essential. We developed a data quality feedback tool that evaluates differences in EHR data quality among practices and software packages as part of a larger intervention. The tool was applied in 92 practices in the Netherlands using different software packages. Practices received data quality feedback in 2010 and 2012. We observed large differences in the quality of recording. For example, the percentage of episodes of care that had a meaningful diagnostic code ranged from 30% to 100%. Differences were highly related to the software package. A year after the first measurement, the quality of recording had improved significantly and differences decreased, with 67% of the physicians indicating that they had actively changed their recording habits based on the results of the first measurement. About 80% found the feedback helpful in pinpointing recording problems. One of the software vendors made changes in functionality as a result of the feedback. Our EHR data quality feedback tool is capable of highlighting differences among practices and software packages. As such, it also stimulates improvements. As substantial variability in recording is related to the software package, our study strengthens the evidence that data quality can be improved substantially by standardizing the functionalities of EHR software packages. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Software for Improved Extraction of Data From Tape Storage

    NASA Technical Reports Server (NTRS)

    Cheng, Chiu-Fu

    2003-01-01

    A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are used at Stennis Space Center. The original software could be activated by a command- line interface only; the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

  11. Software for Improved Extraction of Data From Tape Storage

    NASA Technical Reports Server (NTRS)

    Cheng, Chiu-Fu

    2002-01-01

    A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

  12. SMART trial: A randomized clinical trial of self-monitoring in behavioral weight management-design and baseline findings

    PubMed Central

    Burke, Lora E.; Styn, Mindi A.; Glanz, Karen; Ewing, Linda J.; Elci, Okan U.; Conroy, Margaret B.; Sereika, Susan M.; Acharya, Sushama D.; Music, Edvin; Keating, Alison L.; Sevick, Mary Ann

    2009-01-01

    Background The primary form of treatment for obesity today is behavioral therapy. Self-monitoring diet and physical activity plays an important role in interventions targeting behavior and weight change. The SMART weight loss trial examined the impact of replacing the standard paper record used for self-monitoring with a personal digital assistant (PDA). This paper describes the design, methods, intervention, and baseline sample characteristics of the SMART trial. Methods The SMART trial used a 3-group design to determine the effects of different modes of self-monitoring on short- and long-term weight loss and on adherence to self-monitoring in a 24-month intervention. Participants were randomized to one of three conditions (1) use of a standard paper record (PR); (2) use of a PDA with dietary and physical activity software (PDA); or (3), use of a PDA with the same software plus a customized feedback program (PDA + FB). Results We screened 704 individuals and randomized 210. There were statistically but not clinically significant differences among the three cohorts in age, education, HDL cholesterol, blood glucose and systolic blood pressure. At 24 months, retention rate for the first of three cohorts was 90%. Conclusions To the best of our knowledge, the SMART trial is the first large study to compare different methods of self-monitoring in a behavioral weight loss intervention and to compare the use of PDAs to conventional paper records. This study has the potential to reveal significant details about self-monitoring patterns and whether technology can improve adherence to this vital intervention component. PMID:19665588

  13. Estimating the Overdiagnosis Fraction in Cancer Screening | Division of Cancer Prevention

    Cancer.gov

    By Stuart G. Baker, 2017 Introduction This software supports the mathematical investigation into estimating the fraction of cancers detected on screening that are overdiagnosed. References Baker SG and Prorok PC. Estimating the overdiagnosis fraction in cancer screening. Requirement Mathematica Version 11 or later. |

  14. Evidence-based development and first usability testing of a social serious game based multi-modal system for early screening for atypical socio-cognitive development.

    PubMed

    Gyori, Miklos; Borsos, Zsófia; Stefanik, Krisztina

    2015-01-01

    At current, screening for, and diagnosis of, autism spectrum disorders (ASD) are based on purely behavioral data; established screening tools rely on human observation and ratings of relevant behaviors. The research and development project in the focus of this paper is aimed at designing, creating and evaluating a social serious game based multi-modal, interactive software system for screening for high functioning cases of ASD at kindergarten age. The aims of this paper are (1) to summarize the evidence-based design process and (2) to present results from the first usability test of the system. Game topic, candidate responses, and candidate game contents were identified via an iterative literature review. On this basis, the 1st partial prototype of the fully playable game has been created, with complete data recording functionality but without the decision making component. A first usability test was carried out on this prototype (n=13). Overall results were unambiguously promising. Although sporadic difficulties in, and slightly negative attitudes towards, using the game occasionally arose, these were confined to non-target-group children only. The next steps of development include (1) completing the game design; (2) carrying out first large-n field test; (3) creating the first prototype of the decision making component.

  15. Effects of Social Injustice on Breast Health–Seeking Behaviors of Low-Income Women

    PubMed Central

    Bowen, Shelly-Ann; Williams, Edith M.; Stoneberg-Cooper, Chayah M.; Glover, Saundra H.; Williams, Michelle S.; Byrd, Michael D.

    2014-01-01

    Purpose The study uses qualitative research to gain a better understanding of what occurs after low-income women receive an abnormal breast screening and the factors that influence their decisions and behavior. A heuristic model is presented for understanding this complexity. Design Qualitative research methods used to elicited social and cultural themes related to breast cancer screening follow-up. Setting Individual telephone interviews were conducted with 16 women with confirmed breast anomaly. Participants Low-income women screened through a national breast cancer early detection program. Method Grounded theory using selective coding was employed to elicit factors that influenced the understanding and follow-up of an abnormal breast screening result. Interviews were digitally recorded, transcribed, and uploaded into NVivo 8, a qualitative management and analysis software package. Results For women (16, or 72% of case management referrals) below 250% of the poverty level, the impact of social and economic inequities creates a psychosocial context underlined by structural and cultural barriers to treatment that forecasts the mechanism that generates differences in health outcomes. The absence of insurance due to underemployment and unemployment and inadequate public infrastructure intensified emotional stress impacting participants’ health decisions. Conclusion The findings that emerged offer explanations of how consistent patterns of social injustice impact treatment decisions in a high-risk vulnerable population that have implications for health promotion research and systems-level program improvement and development. PMID:23448411

  16. Automatic Generation of Overlays and Offset Values Based on Visiting Vehicle Telemetry and RWS Visuals

    NASA Technical Reports Server (NTRS)

    Dunne, Matthew J.

    2011-01-01

    The development of computer software as a tool to generate visual displays has led to an overall expansion of automated computer generated images in the aerospace industry. These visual overlays are generated by combining raw data with pre-existing data on the object or objects being analyzed on the screen. The National Aeronautics and Space Administration (NASA) uses this computer software to generate on-screen overlays when a Visiting Vehicle (VV) is berthing with the International Space Station (ISS). In order for Mission Control Center personnel to be a contributing factor in the VV berthing process, computer software similar to that on the ISS must be readily available on the ground to be used for analysis. In addition, this software must perform engineering calculations and save data for further analysis.

  17. 78 FR 21308 - Medicare Program; Physicians' Referrals to Health Care Entities With Which They Have Financial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... electronic health records software and directly related training services, using our authority at section... electronic health records software or information technology and training services. As set forth at 42 CFR...), we explained that we interpreted ``software, information technology and training services necessary...

  18. Approaches to virtual screening and screening library selection.

    PubMed

    Wildman, Scott A

    2013-01-01

    The ease of access to virtual screening (VS) software in recent years has resulted in a large increase in literature reports. Over 300 publications in the last year report the use of virtual screening techniques to identify new chemical matter or present the development of new virtual screening techniques. The increased use is accompanied by a corresponding increase in misuse and misinterpretation of virtual screening results. This review aims to identify many of the common difficulties associated with virtual screening and allow researchers to better assess the reliability of their virtual screening effort.

  19. 76 FR 39315 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security/ALL-030 Use of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... Terrorist Screening Database System of Records AGENCY: Privacy Office, DHS. ACTION: Notice of proposed... Use of the Terrorist Screening Database System of Records'' and this proposed rulemaking. In this... Use of the Terrorist Screening Database (TSDB) System of Records.'' DHS is maintaining a mirror copy...

  20. A Diabetes Dashboard and Physician Efficiency and Accuracy in Accessing Data Needed for High-Quality Diabetes Care

    PubMed Central

    Koopman, Richelle J.; Kochendorfer, Karl M.; Moore, Joi L.; Mehr, David R.; Wakefield, Douglas S.; Yadamsuren, Borchuluun; Coberly, Jared S.; Kruse, Robin L.; Wakefield, Bonnie J.; Belden, Jeffery L.

    2011-01-01

    PURPOSE We compared use of a new diabetes dashboard screen with use of a conventional approach of viewing multiple electronic health record (EHR) screens to find data needed for ambulatory diabetes care. METHODS We performed a usability study, including a quantitative time study and qualitative analysis of information-seeking behaviors. While being recorded with Morae Recorder software and “think-aloud” interview methods, 10 primary care physicians first searched their EHR for 10 diabetes data elements using a conventional approach for a simulated patient, and then using a new diabetes dashboard for another. We measured time, number of mouse clicks, and accuracy. Two coders analyzed think-aloud and interview data using grounded theory methodology. RESULTS The mean time needed to find all data elements was 5.5 minutes using the conventional approach vs 1.3 minutes using the diabetes dashboard (P <.001). Physicians correctly identified 94% of the data requested using the conventional method, vs 100% with the dashboard (P <.01). The mean number of mouse clicks was 60 for conventional searching vs 3 clicks with the diabetes dashboard (P <.001). A common theme was that in everyday practice, if physicians had to spend too much time searching for data, they would either continue without it or order a test again. CONCLUSIONS Using a patient-specific diabetes dashboard improves both the efficiency and accuracy of acquiring data needed for high-quality diabetes care. Usability analysis tools can provide important insights into the value of optimizing physician use of health information technologies. PMID:21911758

  1. DigiSeis—A software component for digitizing seismic signals using the PC sound card

    NASA Astrophysics Data System (ADS)

    Amin Khan, Khalid; Akhter, Gulraiz; Ahmad, Zulfiqar

    2012-06-01

    An innovative software-based approach to develop an inexpensive experimental seismic recorder is presented. This approach requires no hardware as the built-in PC sound card is used for digitization of seismic signals. DigiSeis, an ActiveX component is developed to capture the digitized seismic signals from the sound card and deliver them to applications for processing and display. A seismic recorder application software SeisWave is developed over this component, which provides real-time monitoring and display of seismic events picked by a pair of external geophones. This recorder can be used as an educational aid for conducting seismic experiments. It can also be connected with suitable seismic sensors to record earthquakes. The software application and the ActiveX component are available for download. This component can be used to develop seismic recording applications according to user specific requirements.

  2. Using Docker Compose for the Simple Deployment of an Integrated Drug Target Screening Platform.

    PubMed

    List, Markus

    2017-06-10

    Docker virtualization allows for software tools to be executed in an isolated and controlled environment referred to as a container. In Docker containers, dependencies are provided exactly as intended by the developer and, consequently, they simplify the distribution of scientific software and foster reproducible research. The Docker paradigm is that each container encapsulates one particular software tool. However, to analyze complex biomedical data sets, it is often necessary to combine several software tools into elaborate workflows. To address this challenge, several Docker containers need to be instantiated and properly integrated, which complicates the software deployment process unnecessarily. Here, we demonstrate how an extension to Docker, Docker compose, can be used to mitigate these problems by providing a unified setup routine that deploys several tools in an integrated fashion. We demonstrate the power of this approach by example of a Docker compose setup for a drug target screening platform consisting of five integrated web applications and shared infrastructure, deployable in just two lines of codes.

  3. The Toxicity Estimation Software Tool (T.E.S.T.)

    EPA Science Inventory

    The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to estimate toxicological values for aquatic and mammalian species considering acute and chronic endpoints for screening purposes within TSCA and REACH programs.

  4. [Targeted newborn screening for sickle-cell anemia: Sickling test (Emmel test) boundaries in the prenatal assessment in West African area].

    PubMed

    Diallo, D A; Guindo, A; Touré, B A; Sarro, Y S; Sima, M; Tessougué, O; Baraika, M A; Guindo, P; Traoré, M; Diallo, M; Dorie, A

    2018-05-01

    Newborn screening for sickle cell anemia is necessary in Africa where the disease is more frequent. Hemoglobin electrophoresis is used for screening, but is limited by a high cost and difficult access. Sickling test (Emmel test), which is more affordable and technically more accessible, is often requested for prenatal assessment of pregnant women in West African areas to reserve screening for newborns from mothers in whom the positive sickling test attests the presence of hemoglobin S. This study aims to evaluate the number of undetected sickle cell anemia newborns by a screening policy targeting only newborns from mothers in whom a sickling test would have been positive. From 2010 to 2012, in Bamako, Mali, West Africa, 2489 newborns were routinely screened for sickle cell anemia at the umbilical cord or heel by isoelectrofocusing and, if necessary, by high-performance liquid chromatography. These newborns were born from 2420 mothers whose hemoglobin was studied by isoelectrofocusing. The data was recorded and processed using Excel software version 14.0.0. We calculated the frequency of the sickle cell gene in mothers and newborns as well as the number of SCA newborns from heterozygous or C homozygous mothers. Of the 2489 newborns, 16 had sickle cell anemia (6 SS and 10 SC); 198 had the sickle cell trait; 139 were AC and 1 was CC. Of the 10 newborns with SC profile, 3 were born from mothers not carrying the S gene but the C gene of hemoglobin and in which an Emmel test would have been negative. Targeted newborn screening, based on the results of sickling test in pregnant women, would misdiagnose more than one of six sickle cell anemia newborns who would not benefit from early care. Cost-effectiveness studies of routine newborn screening for sickle cell anemia should lead to a better screening strategy in contexts where hemoglobin S and other hemoglobin defect genes coexist. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... of public domain computer software. (a) General. This section prescribes the procedures for... software under section 805 of Public Law 101-650, 104 Stat. 5089 (1990). Documents recorded in the...

  6. Virtual screening using MTiOpenScreen and PyRx 0,8 revealed ZINC95486216 as a human acetylcholinesterase inhibitor candidate

    NASA Astrophysics Data System (ADS)

    Sulistyo Dwi K., P.; Arindra Trisna, W.; Vindri Catur P., W.; Wijayanti, Erna; Ichsan, Mochammad

    2016-03-01

    One of the efforts to prevent Alzheimer's disease becomes more severe is by inhibiting the activity of Human acetylcholinesterase enzyme (PDB ID: 4BDT). In this study, virtual screening againts 885 natural compounds from AfroDB has been done using MTIOpenScreen and this step has been successful in identifying ZINC15121024 (-12,9) and ZINC95486216 (-12,7) as the top rank compounds. This data then strengthened by the results of second docking step using Autodock software that has been integrated in PyRx 0.8 software. From this stage, ZINC95486216 (-11,3 kcal/mol) is a compound with the most negative binding affinity compared with four Alzheimer's drugs that have been officially used to date including Rivastigmine (-6,3 Kcal/mol), Donepenzil (-7.9 kcal/mol), Galantamine (-8.4 kcal/mol), and Huprine W (-7.3 kcal/mol). In addition, based on the results of the 2D and 3D visualization using LigPlus and PyMol softwares, respectively, known that the five compounds above are equally capable of binding to several amino acids (Trp 286, Phe295, and Tyr341) located in the active site of Human Acetylcholinesterase enzyme.

  7. 24 CFR 5.903 - What special authority is there to obtain access to criminal records?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... criminal conviction records, may be a basis for applicant screening, lease enforcement or eviction, as... determination whether such criminal conviction records may be a basis for applicant screening, lease enforcement...) Screening. If you are an owner of covered housing, you may request that the PHA in the jurisdiction of the...

  8. DOVIS 2.0: an efficient and easy to use parallel virtual screening tool based on AutoDock 4.0.

    PubMed

    Jiang, Xiaohui; Kumar, Kamal; Hu, Xin; Wallqvist, Anders; Reifman, Jaques

    2008-09-08

    Small-molecule docking is an important tool in studying receptor-ligand interactions and in identifying potential drug candidates. Previously, we developed a software tool (DOVIS) to perform large-scale virtual screening of small molecules in parallel on Linux clusters, using AutoDock 3.05 as the docking engine. DOVIS enables the seamless screening of millions of compounds on high-performance computing platforms. In this paper, we report significant advances in the software implementation of DOVIS 2.0, including enhanced screening capability, improved file system efficiency, and extended usability. To keep DOVIS up-to-date, we upgraded the software's docking engine to the more accurate AutoDock 4.0 code. We developed a new parallelization scheme to improve runtime efficiency and modified the AutoDock code to reduce excessive file operations during large-scale virtual screening jobs. We also implemented an algorithm to output docked ligands in an industry standard format, sd-file format, which can be easily interfaced with other modeling programs. Finally, we constructed a wrapper-script interface to enable automatic rescoring of docked ligands by arbitrarily selected third-party scoring programs. The significance of the new DOVIS 2.0 software compared with the previous version lies in its improved performance and usability. The new version makes the computation highly efficient by automating load balancing, significantly reducing excessive file operations by more than 95%, providing outputs that conform to industry standard sd-file format, and providing a general wrapper-script interface for rescoring of docked ligands. The new DOVIS 2.0 package is freely available to the public under the GNU General Public License.

  9. Applying Minimal Manual Principles for Documentation of Graphical User Interfaces.

    ERIC Educational Resources Information Center

    Nowaczyk, Ronald H.; James, E. Christopher

    1993-01-01

    Investigates the need to include computer screens in documentation for software using a graphical user interface. Describes the uses and purposes of "minimal manuals" and their principles. Studies student reaction to their use of one of three on-screen manuals: screens, icon, and button. Finds some benefit for including icon and button…

  10. Designing a Visual Factors-Based Screen Display Interface: The New Role of the Graphic Technologist.

    ERIC Educational Resources Information Center

    Faiola, Tony; DeBloois, Michael L.

    1988-01-01

    Discusses the role of the graphic technologist in preparing computer screen displays for interactive videodisc systems, and suggests screen design guidelines. Topics discussed include the grid system; typography; visual factors research; color; course mobility through branching and software menus; and a model of course integration. (22 references)…

  11. Recording Computer-Based Demonstrations and Board Work

    ERIC Educational Resources Information Center

    Spencer, Neil H.

    2010-01-01

    This article describes how a demonstration of statistical (or other) software can be recorded without expensive video equipment and saved as a presentation to be displayed with software such as Microsoft PowerPoint. Work carried out on a tablet PC, for example, can also be recorded in this fashion.

  12. Cervical cancer screening in Middle Eastern and Asian migrants to Australia: a record linkage study.

    PubMed

    Aminisani, Nayyereh; Armstrong, Bruce K; Canfell, Karen

    2012-12-01

    Australia's organized cervical screening program recommends two-yearly screening for women aged 18-69 years and reminder letters are sent at 27 months. Cervical screening registers hold comprehensive information on screening, but not country of birth. A linkage study was performed in order to assess cervical screening behavior in migrants. To assess screening participation, we linked year 2000 records for 12,541 Middle Eastern/Asian-born women 20-54 years of age, and an age and area matched random sample of 12,143 Australian-born women in the New South Wales (NSW) Midwives Data Collection (MDC), which records country of birth, to screening register records. Screening behavior after 2000 was assessed in women without a recorded prior cervical abnormality. The odds ratios for being screened at least once within a 3 year period, with reference to Australian-born women and adjusted for age, parity, socioeconomic status and smoking, were 0.88 (95% CI: 0.81-0.97) and 0.74 (95% CI: 0.70-0.79) in women born in the Middle East and Asia, respectively. Screening increased with increasing socioeconomic status (SES), absence of smoking and greater parity in Australian-born women but little, if at all, in migrant women. In a sensitivity analysis in which hospital admitted patients were the source of population samples, some patterns were sufficiently different to suggest that selection for illness can affect the strength and direction of associations in linked data. Migrant women from Asian and Middle-eastern countries are less likely than Australian-born women to participate in cervical screening at the recommended interval. Their likelihood of screening is also less related to socioeconomic status, smoking and parity than that in Australian-born women. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Challenges and Opportunities to Improve Cervical Cancer Screening Rates in US Health Centers through Patient-Centered Medical Home Transformation

    PubMed Central

    Makaroff, Laura; Chung, Michelle; Lin, Sue C.

    2015-01-01

    Over the last 50 years, the incidence of cervical cancer has dramatically decreased. However, health disparities in cervical cancer screening (CCS) persist for women from racial and ethnic minorities and those residing in rural and poor communities. For more than 45 years, federally funded health centers (HCs) have been providing comprehensive, culturally competent, and quality primary health care services to medically underserved communities and vulnerable populations. To enhance the quality of care and to ensure more women served at HCs are screened for cervical cancer, over eight HCs received funding to support patient-centered medical home (PCMH) transformation with goals to increase CCS rates. The study conducted a qualitative analysis using Atlas.ti software to describe the barriers and challenges to CCS and PCMH transformation, to identify potential solutions and opportunities, and to examine patterns in barriers and solutions proposed by HCs. Interrater reliability was assessed using Cohen's Kappa. The findings indicated that HCs more frequently described patient-level barriers to CCS, including demographic, cultural, and health belief/behavior factors. System-level barriers were the next commonly cited, particularly failure to use the full capability of electronic medical records (EMRs) and problems coordinating with external labs or providers. Provider-level barriers were least frequently cited. PMID:25685561

  14. Reduced vision and refractive errors, results from a school vision screening program in Kanchanpur District of far western Nepal.

    PubMed

    Awasthi, S; Pant, B P; Dhakal, H P

    2010-01-01

    At present there is no data available on reduced vision and refractive errors in school children of far western Nepal. So, school screening records were used to obtain data useful for planning of refractive services. Data are provided from school screening conducted by Geta Eye Hospital during February/March 2008. The cases with complete data sets on visual acuity, refractive error and age were included and analyzed using computer software. Of 1165 children (mean age 11.6 ± 2.5 years) examined, 98.8% (n = 1151) had uncorrected visual acuity of 6/9 and better in at least one eye whereas 1.2% (n = 14) had acuity 6/12 and worse in both eyes. Among them, either eye of 9 children improved to 6/9 and better with correction. However, visual acuity was 6/12 and worse in both eyes of 5 children even after correction. There were 24 children with refractive errors (myopia, 1.54%; n = 18 and hypermetropia, 0.51%; n = 6) in at least one eye. The spherical equivalent refraction was not significantly different with age and gender. The incidence of reduced vision and refractive errors among school children of this semi rural district were low.

  15. Technology-assisted title and abstract screening for systematic reviews: a retrospective evaluation of the Abstrackr machine learning tool.

    PubMed

    Gates, Allison; Johnson, Cydney; Hartling, Lisa

    2018-03-12

    Machine learning tools can expedite systematic review (SR) processes by semi-automating citation screening. Abstrackr semi-automates citation screening by predicting relevant records. We evaluated its performance for four screening projects. We used a convenience sample of screening projects completed at the Alberta Research Centre for Health Evidence, Edmonton, Canada: three SRs and one descriptive analysis for which we had used SR screening methods. The projects were heterogeneous with respect to search yield (median 9328; range 5243 to 47,385 records; interquartile range (IQR) 15,688 records), topic (Antipsychotics, Bronchiolitis, Diabetes, Child Health SRs), and screening complexity. We uploaded the records to Abstrackr and screened until it made predictions about the relevance of the remaining records. Across three trials for each project, we compared the predictions to human reviewer decisions and calculated the sensitivity, specificity, precision, false negative rate, proportion missed, and workload savings. Abstrackr's sensitivity was > 0.75 for all projects and the mean specificity ranged from 0.69 to 0.90 with the exception of Child Health SRs, for which it was 0.19. The precision (proportion of records correctly predicted as relevant) varied by screening task (median 26.6%; range 14.8 to 64.7%; IQR 29.7%). The median false negative rate (proportion of records incorrectly predicted as irrelevant) was 12.6% (range 3.5 to 21.2%; IQR 12.3%). The workload savings were often large (median 67.2%, range 9.5 to 88.4%; IQR 23.9%). The proportion missed (proportion of records predicted as irrelevant that were included in the final report, out of the total number predicted as irrelevant) was 0.1% for all SRs and 6.4% for the descriptive analysis. This equated to 4.2% (range 0 to 12.2%; IQR 7.8%) of the records in the final reports. Abstrackr's reliability and the workload savings varied by screening task. Workload savings came at the expense of potentially missing relevant records. How this might affect the results and conclusions of SRs needs to be evaluated. Studies evaluating Abstrackr as the second reviewer in a pair would be of interest to determine if concerns for reliability would diminish. Further evaluations of Abstrackr's performance and usability will inform its refinement and practical utility.

  16. 36 CFR 1235.50 - What specifications and standards for transfer apply to electronic records?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electronic records in a format that is independent of specific hardware or software. Except as specified in... a request from NARA to provide the software to decompress the records. (3) Agencies interested in... organization. Acceptable transfer formats include the Geography Markup Language (GML) as defined by the Open...

  17. Aquatic Acoustic Metrics Interface Utility for Underwater Sound Monitoring and Analysis

    PubMed Central

    Ren, Huiying; Halvorsen, Michele B.; Deng, Zhiqun Daniel; Carlson, Thomas J.

    2012-01-01

    Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. In this paper, we provide a detailed description of a new software package, the Aquatic Acoustic Metrics Interface (AAMI), specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals. In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame. The features of the AAMI software are discussed, and several case studies are presented to illustrate its functionality. PMID:22969353

  18. Aquatic Acoustic Metrics Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2012-12-18

    Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. The new Aquatic Acoustic Metrics Interface Utility Software (AAMI) is specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals.more » In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame.« less

  19. Requirements for prototyping an educational electronic health record: experiences and future directions.

    PubMed

    Kushniruk, Andre; Borycki, Elizabeth; Kuo, Mu-Hsing; Parapini, Eric; Wang, Shu Lin; Ho, Kendall

    2014-01-01

    Electronic health records and related technologies are being increasingly deployed throughout the world. It is expected that upon graduation health professionals will be able to use these technologies in effective and efficient ways. However, educating health professional students about such technologies has lagged behind. There is a need for software that will allow medical, nursing and health informatics students access to this important software to learn how it works and how to use it effectively. Furthermore, electronic health record educational software that is accessed should provide a range of functions including allowing instructors to build patient cases. Such software should also allow for simulation of a course of a patient's stay and the ability to allow instructors to monitor student use of electronic health records. In this paper we describe our work in developing the requirements for an educational electronic health record to support education about this important technology. We also describe a prototype system being developed based on the requirements gathered.

  20. Validation of PC-based Sound Card with Biopac for Digitalization of ECG Recording in Short-term HRV Analysis.

    PubMed

    Maheshkumar, K; Dilara, K; Maruthy, K N; Sundareswaren, L

    2016-07-01

    Heart rate variability (HRV) analysis is a simple and noninvasive technique capable of assessing autonomic nervous system modulation on heart rate (HR) in healthy as well as disease conditions. The aim of the present study was to compare (validate) the HRV using a temporal series of electrocardiograms (ECG) obtained by simple analog amplifier with PC-based sound card (audacity) and Biopac MP36 module. Based on the inclusion criteria, 120 healthy participants, including 72 males and 48 females, participated in the present study. Following standard protocol, 5-min ECG was recorded after 10 min of supine rest by Portable simple analog amplifier PC-based sound card as well as by Biopac module with surface electrodes in Leads II position simultaneously. All the ECG data was visually screened and was found to be free of ectopic beats and noise. RR intervals from both ECG recordings were analyzed separately in Kubios software. Short-term HRV indexes in both time and frequency domain were used. The unpaired Student's t-test and Pearson correlation coefficient test were used for the analysis using the R statistical software. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV. Correlation analysis revealed perfect positive correlation (r = 0.99, P < 0.001) between the values in time and frequency domain obtained by the devices. On the basis of the results of the present study, we suggest that the calculation of HRV values in the time and frequency domains by RR series obtained from the PC-based sound card is probably as reliable as those obtained by the gold standard Biopac MP36.

  1. Prete-moi Ton Logiciel pour Ecrire un Mot (Lend Me Your Software Program So I Can Write a Letter).

    ERIC Educational Resources Information Center

    Mangenot, Francois

    1993-01-01

    A brief discussion and description of one commercially available software package ("Pour Ecrire un Mot") for writing letters of various types uses the love letter as an example of the software's functioning. Answers to the prompting questions on the screen determine the few variable parameters of the text to be generated. (four…

  2. Evidence-based development of a diagnosis-dependent therapy planning system and its implementation in modern diagnostic software.

    PubMed

    Ahlers, M O; Jakstat, H A

    2005-07-01

    The prerequisite for structured individual therapy of craniomandibular dysfunctions is differential diagnostics. Suggestions for the structured recording of findings and their structured evaluation beyond the global diagnosis of "craniomandibular disorders" have been published. Only this structured approach enables computerization of the diagnostic process. The respective software is available for use in practice (CMDcheck for CMD screening, CMDfact for the differential diagnostics). Based on this structured diagnostics, knowledge-based therapy planning is also conceivable. The prerequisite for this would be a model of achieving consensus on the indicated forms of therapy related to the diagnosis. Therefore, a procedure for evidence-based achievement of consensus on suitable forms of therapy in CMD was developed first in multicentric cooperation, and then implemented in corresponding software. The clinical knowledge of experienced specialists was included consciously for the consensus achievement process. At the same time, anonymized mathematical statistical evaluations were used for control and objectification. Different examiners form different departments of several universities working independently of one another assigned the theoretically conceiveable therapeutic alternatives to the already published diagnostic scheme. After anonymization, the correlation of these assignments was then calculated mathematically. For achieving consensus in those cases for which no agreement initally existed, agreement was subsequently arrived at in the course of a consensus conference on the basis of literature evaluations and the discussion of clinical case examples. This consensus in turn finally served as the basis of a therapy planner implemented in the above-mentioned diagnostic software CMDfact. Contributing to quality assurance, the principles of programming this assistant as well as the interface for linking into the diagnostic software are documented and also published here.

  3. Guidance and Control Software Project Data - Volume 4: Configuration Management and Quality Assurance Documents

    NASA Technical Reports Server (NTRS)

    Hayhurst, Kelly J. (Editor)

    2008-01-01

    The Guidance and Control Software (GCS) project was the last in a series of software reliability studies conducted at Langley Research Center between 1977 and 1994. The technical results of the GCS project were recorded after the experiment was completed. Some of the support documentation produced as part of the experiment, however, is serving an unexpected role far beyond its original project context. Some of the software used as part of the GCS project was developed to conform to the RTCA/DO-178B software standard, "Software Considerations in Airborne Systems and Equipment Certification," used in the civil aviation industry. That standard requires extensive documentation throughout the software development life cycle, including plans, software requirements, design and source code, verification cases and results, and configuration management and quality control data. The project documentation that includes this information is open for public scrutiny without the legal or safety implications associated with comparable data from an avionics manufacturer. This public availability has afforded an opportunity to use the GCS project documents for DO-178B training. This report provides a brief overview of the GCS project, describes the 4-volume set of documents and the role they are playing in training, and includes configuration management and quality assurance documents from the GCS project. Volume 4 contains six appendices: A. Software Accomplishment Summary for the Guidance and Control Software Project; B. Software Configuration Index for the Guidance and Control Software Project; C. Configuration Management Records for the Guidance and Control Software Project; D. Software Quality Assurance Records for the Guidance and Control Software Project; E. Problem Report for the Pluto Implementation of the Guidance and Control Software Project; and F. Support Documentation Change Reports for the Guidance and Control Software Project.

  4. Achromatized transmission-type holographic screen for a multiview stereoscopic image system

    NASA Astrophysics Data System (ADS)

    Hwang, Seon-Ho; Bobrinev, V. I.; Son, Jung-Young; Shestak, S. A.; Jeon, Hyung-Wook

    1997-09-01

    The main drawback of the use of transmission-type holographic screens is poor color reproduction caused by their high spectral dispersion. For overcoming this drawback, a long, narrow diffusing slit is used as an object when recording the screen. The necessary size and position of the slit relative to the photoplate and to the recording and reconstruction beams are determined by the phase relations of the beams. By use of the slit, holographic screens of 30 cm 40 cm are recorded with a diverging reference beam and are used to display a multiview full-color stereoscopic image. The images displayed on the screen show no sign of color separation except near the edges of the screen. The image brightness on the screen is high enough that it can be watched in a normally illuminated room.

  5. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  6. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.

  7. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices

    NASA Astrophysics Data System (ADS)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.

  8. Identification of Volunteer Screening Practices for Selected Ohio Youth Organizations.

    ERIC Educational Resources Information Center

    Henderson, Jan; Schmiesing, Ryan J.

    2001-01-01

    Interviews with eight coordinators of youth organization volunteers indicated that most used position descriptions, applications, reference checks, and interviews as screening tools; only four checked motor vehicle records and three checked criminal records. Consistent policies and advanced screening devices were recommended. (SK)

  9. Identification of drug interactions in hospitals--computerized screening vs. bedside recording.

    PubMed

    Blix, H S; Viktil, K K; Moger, T A; Reikvam, A

    2008-04-01

    Managing drug interactions in hospitalized patients is important and challenging. The objective of the study was to compare two methods for identification of drug interactions (DDIs)--computerized screening and prospective bedside recording--with regard to capability of identifying DDIs. Patient characteristics were recorded for patients admitted to five hospitals. By bedside evaluation drug-related problems, including DDIs, were prospectively recorded by pharmacists and discussed in multidisciplinary teams. A computer screening programme was used to identify DDIs retrospectively--dividing DDIs into four classes: A, avoid; B, avoid/take precautions; C, take precautions; D, no action needed. Among 827 patients, computer screening identified DDIs in 544 patients (66%); 351 had DDIs introduced in hospital. The 1513 computer-identified DDIs had the following distribution: type A 78; type B 915; type C 38; type D 482. By bedside evaluation, 99 DDIs were identified in 73 patients (9%). The proportions of computer recorded DDIs which were also identified at the bedside were: 5%, 8%, 8%, 2% DDIs of types A, B, C and D respectively. In 10 patients, DDIs not registered by computer screening were identified by bedside evaluation. The drugs most frequently involved in DDIs, identified by computerized screening were acetylsalicylic acid, warfarin, furosemide and digitoxin compared with warfarin, simvastatin, theophylline and carbamazepine, by bedside evaluation. Despite an active prospective bedside search for DDIs, this approach identified less than one in 10 of the DDIs recorded by computer screening, including those regarded as hazardous. However, computer screening overestimates considerably when the objective is to identify clinically relevant DDIs.

  10. NASA Software Documentation Standard

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The NASA Software Documentation Standard (hereinafter referred to as "Standard") is designed to support the documentation of all software developed for NASA; its goal is to provide a framework and model for recording the essential information needed throughout the development life cycle and maintenance of a software system. The NASA Software Documentation Standard can be applied to the documentation of all NASA software. The Standard is limited to documentation format and content requirements. It does not mandate specific management, engineering, or assurance standards or techniques. This Standard defines the format and content of documentation for software acquisition, development, and sustaining engineering. Format requirements address where information shall be recorded and content requirements address what information shall be recorded. This Standard provides a framework to allow consistency of documentation across NASA and visibility into the completeness of project documentation. The basic framework consists of four major sections (or volumes). The Management Plan contains all planning and business aspects of a software project, including engineering and assurance planning. The Product Specification contains all technical engineering information, including software requirements and design. The Assurance and Test Procedures contains all technical assurance information, including Test, Quality Assurance (QA), and Verification and Validation (V&V). The Management, Engineering, and Assurance Reports is the library and/or listing of all project reports.

  11. Can clinical governance deliver quality improvement in Australian general practice and primary care? A systematic review of the evidence.

    PubMed

    Phillips, Christine B; Pearce, Christopher M; Hall, Sally; Travaglia, Joanne; de Lusignan, Simon; Love, Tom; Kljakovic, Marjan

    2010-11-15

    To review the literature on different models of clinical governance and to explore their relevance to Australian primary health care, and their potential contributions on quality and safety. 25 electronic databases, scanning reference lists of articles and consultation with experts in the field. We searched publications in English after 1999, but a search of the German language literature for a specific model type was also undertaken. The grey literature was explored through a hand search of the medical trade press and websites of relevant national and international clearing houses and professional or industry bodies. 11 software packages commonly used in Australian general practice were reviewed for any potential contribution to clinical governance. 19 high-quality studies that assessed outcomes were included. All abstracts were screened by one researcher, and 10% were screened by a second researcher to crosscheck screening quality. Studies were reviewed and coded by four reviewers, with all studies being rated using standard critical appraisal tools such as the Strengthening the Reporting of Observational Studies in Epidemiology checklist. Two researchers reviewed the Australian general practice software. Interviews were conducted with 16 informants representing service, regional primary health care, national and international perspectives. Most evidence supports governance models which use targeted, peer-led feedback on the clinician's own practice. Strategies most used in clinical governance models were audit, performance against indicators, and peer-led reflection on evidence or performance. The evidence base for clinical governance is fragmented, and focuses mainly on process rather than outcomes. Few publications address models that enhance safety, efficiency, sustainability and the economics of primary health care. Locally relevant clinical indicators, the use of computerised medical record systems, regional primary health care organisations that have the capacity to support the uptake of clinical governance at the practice level, and learning from the Aboriginal community-controlled sector will help integrate clinical governance into primary care.

  12. Information management and analysis system for groundwater data in Thailand

    NASA Astrophysics Data System (ADS)

    Gill, D.; Luckananurung, P.

    1992-01-01

    The Ground Water Division of the Thai Department of Mineral Resources maintains a large archive of groundwater data with information on some 50,000 water wells. Each well file contains information on well location, well completion, borehole geology, water levels, water quality, and pumping tests. In order to enable efficient use of this information a computer-based system for information management and analysis was created. The project was sponsored by the United Nations Development Program and the Thai Department of Mineral Resources. The system was designed to serve users who lack prior training in automated data processing. Access is through a friendly user/system dialogue. Tasks are segmented into a number of logical steps, each of which is managed by a separate screen. Selective retrieval is possible by four different methods of area definition and by compliance with user-specified constraints on any combination of database variables. The main types of outputs are: (1) files of retrieved data, screened according to users' specifications; (2) an assortment of pre-formatted reports; (3) computed geochemical parameters and various diagrams of water chemistry derived therefrom; (4) bivariate scatter diagrams and linear regression analysis; (5) posting of data and computed results on maps; and (6) hydraulic aquifer characteristics as computed from pumping tests. Data are entered directly from formatted screens. Most records can be copied directly from hand-written documents. The database-management program performs data integrity checks in real time, enabling corrections at the time of input. The system software can be grouped into: (1) database administration and maintenance—these functions are carried out by the SIR/DBMS software package; (2) user communication interface for task definition and execution control—the interface is written in the operating system command language (VMS/DCL) and in FORTRAN 77; and (3) scientific data-processing programs, written in FORTRAN 77. The system was implemented on a DEC MicroVAX II computer.

  13. Effects of Iterative Reconstruction Algorithms on Computer-assisted Detection (CAD) Software for Lung Nodules in Ultra-low-dose CT for Lung Cancer Screening.

    PubMed

    Nomura, Yukihiro; Higaki, Toru; Fujita, Masayo; Miki, Soichiro; Awaya, Yoshikazu; Nakanishi, Toshio; Yoshikawa, Takeharu; Hayashi, Naoto; Awai, Kazuo

    2017-02-01

    This study aimed to evaluate the effects of iterative reconstruction (IR) algorithms on computer-assisted detection (CAD) software for lung nodules in ultra-low-dose computed tomography (ULD-CT) for lung cancer screening. We selected 85 subjects who underwent both a low-dose CT (LD-CT) scan and an additional ULD-CT scan in our lung cancer screening program for high-risk populations. The LD-CT scans were reconstructed with filtered back projection (FBP; LD-FBP). The ULD-CT scans were reconstructed with FBP (ULD-FBP), adaptive iterative dose reduction 3D (AIDR 3D; ULD-AIDR 3D), and forward projected model-based IR solution (FIRST; ULD-FIRST). CAD software for lung nodules was applied to each image dataset, and the performance of the CAD software was compared among the different IR algorithms. The mean volume CT dose indexes were 3.02 mGy (LD-CT) and 0.30 mGy (ULD-CT). For overall nodules, the sensitivities of CAD software at 3.0 false positives per case were 78.7% (LD-FBP), 9.3% (ULD-FBP), 69.4% (ULD-AIDR 3D), and 77.8% (ULD-FIRST). Statistical analysis showed that the sensitivities of ULD-AIDR 3D and ULD-FIRST were significantly higher than that of ULD-FBP (P < .001). The performance of CAD software in ULD-CT was improved by using IR algorithms. In particular, the performance of CAD in ULD-FIRST was almost equivalent to that in LD-FBP. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Virtual Environment TBI Screen (VETS)

    DTIC Science & Technology

    2014-10-01

    balance challenges performed on a modified Wii Balance Board . Implementation of this device will enhance current approaches in TBI and mild TBI (i.e...TBI) screen (VETS) device in measuring standing balance . This system consists of software, a Wii balance board , and a large screen television that...Validate Wii ™ Balance Board relative to NeuroCom forceplate ! Running Wii Balance Board validation protocol. ! Milestone Achieved:

  15. Large Scale Screening of Low Cost Ferritic Steel Designs For Advanced Ultra Supercritical Boiler Using First Principles Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, Lizhi

    Advanced Ultra Supercritical Boiler (AUSC) requires materials that can operate in corrosive environment at temperature and pressure as high as 760°C (or 1400°F) and 5000psi, respectively, while at the same time maintain good ductility at low temperature. We develop automated simulation software tools to enable fast large scale screening studies of candidate designs. While direct evaluation of creep rupture strength and ductility are currently not feasible, properties such as energy, elastic constants, surface energy, interface energy, and stack fault energy can be used to assess their relative ductility and creeping strength. We implemented software to automate the complex calculations tomore » minimize human inputs in the tedious screening studies which involve model structures generation, settings for first principles calculations, results analysis and reporting. The software developed in the project and library of computed mechanical properties of phases found in ferritic steels, many are complex solid solutions estimated for the first time, will certainly help the development of low cost ferritic steel for AUSC.« less

  16. From Classroom to Computer Screen: NWLP Software. A Set of Computerized Garment-Related Bilingual (English and Chinese) Literacy Lessons.

    ERIC Educational Resources Information Center

    Whu, Lin Fai; Zhang, Ai Ling

    This document describes how National Workplace Literacy Program (NWLP) software was developed for Chinese garment workers in New York City. First, it discusses the goal of the workplace literacy program and the nature of the population served. Then, it indicates how NWLP software was designed to supplement the NWLP curriculum and to reinforce the…

  17. Retina Image Screening and Analysis Software Version 2.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tobin, Jr., Kenneth W.; Karnowski, Thomas P.; Aykac, Deniz

    2009-04-01

    The software allows physicians or researchers to ground-truth images of retinas, identifying key physiological features and lesions that are indicative of disease. The software features methods to automatically detect the physiological features and lesions. The software contains code to measure the quality of images received from a telemedicine network; create and populate a database for a telemedicine network; review and report the diagnosis of a set of images; and also contains components to transmit images from a Zeiss camera to the network through SFTP.

  18. Web Extensible Display Manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slominski, Ryan; Larrieu, Theodore L.

    Jefferson Lab's Web Extensible Display Manager (WEDM) allows staff to access EDM control system screens from a web browser in remote offices and from mobile devices. Native browser technologies are leveraged to avoid installing and managing software on remote clients such as browser plugins, tunnel applications, or an EDM environment. Since standard network ports are used firewall exceptions are minimized. To avoid security concerns from remote users modifying a control system, WEDM exposes read-only access and basic web authentication can be used to further restrict access. Updates of monitored EPICS channels are delivered via a Web Socket using a webmore » gateway. The software translates EDM description files (denoted with the edl suffix) to HTML with Scalable Vector Graphics (SVG) following the EDM's edl file vector drawing rules to create faithful screen renderings. The WEDM server parses edl files and creates the HTML equivalent in real-time allowing existing screens to work without modification. Alternatively, the familiar drag and drop EDM screen creation tool can be used to create optimized screens sized specifically for smart phones and then rendered by WEDM.« less

  19. Our experiences with development of digitised video streams and their use in animal-free medical education.

    PubMed

    Cervinka, Miroslav; Cervinková, Zuzana; Novák, Jan; Spicák, Jan; Rudolf, Emil; Peychl, Jan

    2004-06-01

    Alternatives and their teaching are an essential part of the curricula at the Faculty of Medicine. Dynamic screen-based video recordings are the most important type of alternative models employed for teaching purposes. Currently, the majority of teaching materials for this purpose are based on PowerPoint presentations, which are very popular because of their high versatility and visual impact. Furthermore, current developments in the field of image capturing devices and software enable the use of digitised video streams, tailored precisely to the specific situation. Here, we demonstrate that with reasonable financial resources, it is possible to prepare video sequences and to introduce them into the PowerPoint presentation, thereby shaping the teaching process according to individual students' needs and specificities.

  20. Toward Software Both Seen and Heard.

    ERIC Educational Resources Information Center

    Lazzaro, Joseph J.

    1996-01-01

    Visually impaired users are hampered by current PC software written for graphical user interfaces. Screen readers that vocalize displayed text require standardization that remains missing in the programming industry; the readers cannot interpret many cues in the Windows environment. More programming standards and adaptive technology for computers…

  1. Toolkit of Available EPA Green Infrastructure Modeling Software: Watershed Management Optimization Support Tool (WMOST)

    EPA Science Inventory

    Watershed Management Optimization Support Tool (WMOST) is a software application designed tofacilitate integrated water resources management across wet and dry climate regions. It allows waterresources managers and planners to screen a wide range of practices across their watersh...

  2. CellProfiler and KNIME: open source tools for high content screening.

    PubMed

    Stöter, Martin; Niederlein, Antje; Barsacchi, Rico; Meyenhofer, Felix; Brandl, Holger; Bickle, Marc

    2013-01-01

    High content screening (HCS) has established itself in the world of the pharmaceutical industry as an essential tool for drug discovery and drug development. HCS is currently starting to enter the academic world and might become a widely used technology. Given the diversity of problems tackled in academic research, HCS could experience some profound changes in the future, mainly with more imaging modalities and smart microscopes being developed. One of the limitations in the establishment of HCS in academia is flexibility and cost. Flexibility is important to be able to adapt the HCS setup to accommodate the multiple different assays typical of academia. Many cost factors cannot be avoided, but the costs of the software packages necessary to analyze large datasets can be reduced by using Open Source software. We present and discuss the Open Source software CellProfiler for image analysis and KNIME for data analysis and data mining that provide software solutions which increase flexibility and keep costs low.

  3. 28 CFR 802.4 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Administration COURT SERVICES AND OFFENDER SUPERVISION AGENCY FOR THE DISTRICT OF COLUMBIA DISCLOSURE OF RECORDS... proprietary interest in the information. (e) Computer software means tools by which records are created, stored, and retrieved. Normally, computer software, including source code, object code, and listings of...

  4. Astronaut Health Participant Summary Application

    NASA Technical Reports Server (NTRS)

    Johnson, Kathy; Krog, Ralph; Rodriguez, Seth; Wear, Mary; Volpe, Robert; Trevino, Gina; Eudy, Deborah; Parisian, Diane

    2011-01-01

    The Longitudinal Study of Astronaut Health (LSAH) Participant Summary software captures data based on a custom information model designed to gather all relevant, discrete medical events for its study participants. This software provides a summarized view of the study participant s entire medical record. The manual collapsing of all the data in a participant s medical record into a summarized form eliminates redundancy, and allows for the capture of entire medical events. The coding tool could be incorporated into commercial electronic medical record software for use in areas like public health surveillance, hospital systems, clinics, and medical research programs.

  5. Contribution of Electronic Medical Records to the Management of Rare Diseases.

    PubMed

    Bremond-Gignac, Dominique; Lewandowski, Elisabeth; Copin, Henri

    2015-01-01

    Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR) in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients' data with ophthalmology-specific EMR. Ophthalmology-specific EMR software (Softalmo software Corilus) was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease.

  6. Contribution of Electronic Medical Records to the Management of Rare Diseases

    PubMed Central

    Bremond-Gignac, Dominique; Lewandowski, Elisabeth; Copin, Henri

    2015-01-01

    Purpose. Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR) in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients' data with ophthalmology-specific EMR. Methods. Ophthalmology-specific EMR software (Softalmo software Corilus) was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. Results. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. Discussion. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Conclusion. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease. PMID:26539543

  7. A Proven Method for Meeting Export Control Objectives in Postal and Shipping Sectors

    DTIC Science & Technology

    2015-02-01

    Mellon University for the operation of the Software Engineering Institute, a federally funded research and development center sponsored by the United...Export Control at USPS 5 3.3 Objectives for Improving Export Screening at USPS 6 4 Development of the New Screening Process 7 4.1 “Walking the Model...Export Screening Development Process 10 Figure 2: Induction and Processing of International Mail 10 Figure 3: The Export Screening Process 11

  8. P1198: software for tracing decision behavior in lending to small businesses.

    PubMed

    Andersson, P

    2001-05-01

    This paper describes a process-tracing software program specially designed to capture decision behavior in lending to small businesses. The source code was written in Lotus Notes. The software runs in a Web browser and consists of two interacting systems: a database and a user interface. The database includes three realistic loan applications. The user interface consists of different but interacting screens that enable the participant to operate the software. Log files register the decision behavior of the participant. An empirical example is presented in order to show the software's potential in providing insights into judgment and decision making. The implications of the software are discussed.

  9. CellSegm - a MATLAB toolbox for high-throughput 3D cell segmentation

    PubMed Central

    2013-01-01

    The application of fluorescence microscopy in cell biology often generates a huge amount of imaging data. Automated whole cell segmentation of such data enables the detection and analysis of individual cells, where a manual delineation is often time consuming, or practically not feasible. Furthermore, compared to manual analysis, automation normally has a higher degree of reproducibility. CellSegm, the software presented in this work, is a Matlab based command line software toolbox providing an automated whole cell segmentation of images showing surface stained cells, acquired by fluorescence microscopy. It has options for both fully automated and semi-automated cell segmentation. Major algorithmic steps are: (i) smoothing, (ii) Hessian-based ridge enhancement, (iii) marker-controlled watershed segmentation, and (iv) feature-based classfication of cell candidates. Using a wide selection of image recordings and code snippets, we demonstrate that CellSegm has the ability to detect various types of surface stained cells in 3D. After detection and outlining of individual cells, the cell candidates can be subject to software based analysis, specified and programmed by the end-user, or they can be analyzed by other software tools. A segmentation of tissue samples with appropriate characteristics is also shown to be resolvable in CellSegm. The command-line interface of CellSegm facilitates scripting of the separate tools, all implemented in Matlab, offering a high degree of flexibility and tailored workflows for the end-user. The modularity and scripting capabilities of CellSegm enable automated workflows and quantitative analysis of microscopic data, suited for high-throughput image based screening. PMID:23938087

  10. CellSegm - a MATLAB toolbox for high-throughput 3D cell segmentation.

    PubMed

    Hodneland, Erlend; Kögel, Tanja; Frei, Dominik Michael; Gerdes, Hans-Hermann; Lundervold, Arvid

    2013-08-09

    : The application of fluorescence microscopy in cell biology often generates a huge amount of imaging data. Automated whole cell segmentation of such data enables the detection and analysis of individual cells, where a manual delineation is often time consuming, or practically not feasible. Furthermore, compared to manual analysis, automation normally has a higher degree of reproducibility. CellSegm, the software presented in this work, is a Matlab based command line software toolbox providing an automated whole cell segmentation of images showing surface stained cells, acquired by fluorescence microscopy. It has options for both fully automated and semi-automated cell segmentation. Major algorithmic steps are: (i) smoothing, (ii) Hessian-based ridge enhancement, (iii) marker-controlled watershed segmentation, and (iv) feature-based classfication of cell candidates. Using a wide selection of image recordings and code snippets, we demonstrate that CellSegm has the ability to detect various types of surface stained cells in 3D. After detection and outlining of individual cells, the cell candidates can be subject to software based analysis, specified and programmed by the end-user, or they can be analyzed by other software tools. A segmentation of tissue samples with appropriate characteristics is also shown to be resolvable in CellSegm. The command-line interface of CellSegm facilitates scripting of the separate tools, all implemented in Matlab, offering a high degree of flexibility and tailored workflows for the end-user. The modularity and scripting capabilities of CellSegm enable automated workflows and quantitative analysis of microscopic data, suited for high-throughput image based screening.

  11. Automated touch screen device for recording complex rodent behaviors

    PubMed Central

    Mabrouk, O.S.; Dripps, I.J.; Ramani, S.; Chang, C.; Han, J.L.; Rice, KC; Jutkiewicz, E.M.

    2016-01-01

    Background Monitoring mouse behavior is a critical step in the development of modern pharmacotherapies. New Method Here we describe the application of a novel method that utilizes a touch display computer (tablet) and software to detect, record, and report fine motor behaviors. A consumer-grade tablet device is placed in the bottom of a specially made acrylic cage allowing the animal to walk on the device (MouseTrapp). We describe its application in open field (for general locomotor studies) which measures step lengths and velocity. The device can perform light-dark (anxiety) tests by illuminating half of the screen and keeping the other half darkened. A divider is built into the lid of the device allowing the animal free access to either side. Results Treating mice with amphetamine and the delta opioid peptide receptor agonist SNC80 stimulated locomotor activity on the device. Amphetamine increased step velocity but not step length during its peak effect (40–70 min after treatment), thus indicating detection of subtle amphetamine-induced effects. Animals showed a preference (74% of time spent) for the darkened half compared to the illuminated side. Comparison with Existing Method Animals were videotaped within the chamber to compare quadrant crosses to detected motion on the device. The slope, duration and magnitude of quadrant crosses tightly correlated with overall locomotor activity as detected by Mousetrapp. Conclusions We suggest that modern touch display devices such as MouseTrapp will be an important step toward automation of behavioral analyses for characterizing phenotypes and drug effects. PMID:24952323

  12. Automated registration of tail bleeding in rats.

    PubMed

    Johansen, Peter B; Henriksen, Lars; Andresen, Per R; Lauritzen, Brian; Jensen, Kåre L; Juhl, Trine N; Tranholm, Mikael

    2008-05-01

    An automated system for registration of tail bleeding in rats using a camera and a user-designed PC-based software program has been developed. The live and processed images are displayed on the screen and are exported together with a text file for later statistical processing of the data allowing calculation of e.g. number of bleeding episodes, bleeding times and bleeding areas. Proof-of-principle was achieved when the camera captured the blood stream after infusion of rat whole blood into saline. Suitability was assessed by recording of bleeding profiles in heparin-treated rats, demonstrating that the system was able to capture on/off bleedings and that the data transfer and analysis were conducted successfully. Then, bleeding profiles were visually recorded by two independent observers simultaneously with the automated recordings after tail transection in untreated rats. Linear relationships were found in the number of bleedings, demonstrating, however, a statistically significant difference in the recording of bleeding episodes between observers. Also, the bleeding time was longer for visual compared to automated recording. No correlation was found between blood loss and bleeding time in untreated rats, but in heparinized rats a correlation was suggested. Finally, the blood loss correlated with the automated recording of bleeding area. In conclusion, the automated system has proven suitable for replacing visual recordings of tail bleedings in rats. Inter-observer differences can be eliminated, monotonous repetitive work avoided, and a higher through-put of animals in less time achieved. The automated system will lead to an increased understanding of the nature of bleeding following tail transection in different rodent models.

  13. Using a Geographic Information System to Improve Childhood Lead-Screening Efforts

    PubMed Central

    2013-01-01

    The Idaho Division of Public Health conducted a pilot study to produce a lead-exposure–risk map to help local and state agencies better target childhood lead-screening efforts. Priority lead-screening areas, at the block group level, were created by using county tax assessor data and geographic information system software. A series of maps were produced, indicating childhood lead-screening prevalence in areas in which there was high potential for exposure to lead. These maps could enable development of more systematically targeted and cost-effective childhood lead-screening efforts. PMID:23764346

  14. Laboratory Connections: Review of Two Commercial Interfacing Packages.

    ERIC Educational Resources Information Center

    Powers, Michael H.

    1989-01-01

    Evaluates two Apple II interfacing packages designed to measure pH: (1) "Experiments in Chemistry" by HRM Software and (2) "Voltage Plotter III" by Vernier Software. Provides characteristics and screen dumps of each package. Reports both systems are suitable for high school or beginning college laboratories. (MVL)

  15. Prototyping with Data Dictionaries for Requirements Analysis.

    DTIC Science & Technology

    1985-03-01

    statistical packages and software for screen layout. These items work at a higher level than another category of prototyping tool, program generators... Program generators are software packages which, when given specifications, produce source listings, usually in a high order language such as COBCL...with users and this will not happen if he must stop to develcp a detailed program . [Ref. 241] Hardware as well as software should be considered in

  16. Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

    PubMed

    Funaki, Ayumu; Ohkubo, Masaki; Wada, Shinichi; Murao, Kohei; Matsumoto, Toru; Niizuma, Shinji

    2012-07-01

    With the wide dissemination of computed tomography (CT) screening for lung cancer, measuring the nodule volume accurately with computer-aided volumetry software is increasingly important. Many studies for determining the accuracy of volumetry software have been performed using a phantom with artificial nodules. These phantom studies are limited, however, in their ability to reproduce the nodules both accurately and in the variety of sizes and densities required. Therefore, we propose a new approach of using computer-simulated nodules based on the point spread function measured in a CT system. The validity of the proposed method was confirmed by the excellent agreement obtained between computer-simulated nodules and phantom nodules regarding the volume measurements. A practical clinical evaluation of the accuracy of volumetry software was achieved by adding simulated nodules onto clinical lung images, including noise and artifacts. The tested volumetry software was revealed to be accurate within an error of 20 % for nodules >5 mm and with the difference between nodule density and background (lung) (CT value) being 400-600 HU. Such a detailed analysis can provide clinically useful information on the use of volumetry software in CT screening for lung cancer. We concluded that the proposed method is effective for evaluating the performance of computer-aided volumetry software.

  17. A research strategy for the dynamic study of students' concepts and problem solving strategies using science software

    NASA Astrophysics Data System (ADS)

    Krajcik, Joseph S.; Simmons, Patricia E.; Lunetta, Vincent N.

    Microcomputers and appropriate software have the potential to help students learn. They can also serve as appropriate media for investigating how students learn. In this article we describe a research strategy examining learning and behavior when students interacted with microcomputers and software. Results from two preliminary studies illustrate the strategy.A major feature of the strategy included recording students interacting with microcomputer software interfaced with a VCR. The VCR recorded the video output from a microcomputer and students' verbal commentary via microphone input. This technique allowed students' comments about their observations, perceptions, predictions, explanations, and decisions to be recorded simultaneously with their computer input and the display on the microcomputer monitor.The research strategy described can provide important information about cognitive and affective behaviors of students engaged in using instructional software. Research studies utilizing this strategy can enhance our understanding of how students develop and employ important concepts and scientific relationships, how students develop problem-solving skills and solve problems, and how they interact with instructional software. Results of such studies have important implications for teaching and for the design of instructional software.

  18. Exploring faculty perceptions towards electronic health records for nursing education.

    PubMed

    Kowitlawakul, Y; Chan, S W C; Wang, L; Wang, W

    2014-12-01

    The use of electronic health records in nursing education is rapidly increasing worldwide. The successful implementation of electronic health records for nursing education software program relies on students as well as nursing faculty members. This study aimed to explore the experiences and perceptions of nursing faculty members using electronic health records for nursing education software program, and to identify the influential factors for successful implementation of this technology. This exploratory qualitative study was conducted using in-depth individual interviews at a university in Singapore. Seven faculty members participated in the study. The data were gathered and analysed at the end of the semester in the 2012/2013 academic year. The participants' perceptions of the software program were organized into three main categories: innovation, transition and integration. The participants perceived this technology as innovative, with both values and challenges for the users. In addition, using the new software program was perceived as transitional process. The integration of this technology required time from faculty members and students, as well as support from administrators. The software program had only been implemented for 2-3 months at the time of the interviews. Consequently, the participants might have lacked the necessary skill and competence and confidence to implement it successfully. In addition, the unequal exposure to the software program might have had an impact on participants' perceptions. The findings show that the integration of electronic health records into nursing education curricula is dependent on the faculty members' experiences with the new technology, as well as their perceptions of it. Hence, cultivating a positive attitude towards the use of new technologies is important. Electronic health records are significant applications of health information technology. Health informatics competency should be included as a required competency component in faculty professional development policy and programmes. © 2014 International Council of Nurses.

  19. Design and implementation of a privacy preserving electronic health record linkage tool in Chicago

    PubMed Central

    Cashy, John P; Jackson, Kathryn L; Pah, Adam R; Goel, Satyender; Boehnke, Jörn; Humphries, John Eric; Kominers, Scott Duke; Hota, Bala N; Sims, Shannon A; Malin, Bradley A; French, Dustin D; Walunas, Theresa L; Meltzer, David O; Kaleba, Erin O; Jones, Roderick C; Galanter, William L

    2015-01-01

    Objective To design and implement a tool that creates a secure, privacy preserving linkage of electronic health record (EHR) data across multiple sites in a large metropolitan area in the United States (Chicago, IL), for use in clinical research. Methods The authors developed and distributed a software application that performs standardized data cleaning, preprocessing, and hashing of patient identifiers to remove all protected health information. The application creates seeded hash code combinations of patient identifiers using a Health Insurance Portability and Accountability Act compliant SHA-512 algorithm that minimizes re-identification risk. The authors subsequently linked individual records using a central honest broker with an algorithm that assigns weights to hash combinations in order to generate high specificity matches. Results The software application successfully linked and de-duplicated 7 million records across 6 institutions, resulting in a cohort of 5 million unique records. Using a manually reconciled set of 11 292 patients as a gold standard, the software achieved a sensitivity of 96% and a specificity of 100%, with a majority of the missed matches accounted for by patients with both a missing social security number and last name change. Using 3 disease examples, it is demonstrated that the software can reduce duplication of patient records across sites by as much as 28%. Conclusions Software that standardizes the assignment of a unique seeded hash identifier merged through an agreed upon third-party honest broker can enable large-scale secure linkage of EHR data for epidemiologic and public health research. The software algorithm can improve future epidemiologic research by providing more comprehensive data given that patients may make use of multiple healthcare systems. PMID:26104741

  20. Design and implementation of a privacy preserving electronic health record linkage tool in Chicago.

    PubMed

    Kho, Abel N; Cashy, John P; Jackson, Kathryn L; Pah, Adam R; Goel, Satyender; Boehnke, Jörn; Humphries, John Eric; Kominers, Scott Duke; Hota, Bala N; Sims, Shannon A; Malin, Bradley A; French, Dustin D; Walunas, Theresa L; Meltzer, David O; Kaleba, Erin O; Jones, Roderick C; Galanter, William L

    2015-09-01

    To design and implement a tool that creates a secure, privacy preserving linkage of electronic health record (EHR) data across multiple sites in a large metropolitan area in the United States (Chicago, IL), for use in clinical research. The authors developed and distributed a software application that performs standardized data cleaning, preprocessing, and hashing of patient identifiers to remove all protected health information. The application creates seeded hash code combinations of patient identifiers using a Health Insurance Portability and Accountability Act compliant SHA-512 algorithm that minimizes re-identification risk. The authors subsequently linked individual records using a central honest broker with an algorithm that assigns weights to hash combinations in order to generate high specificity matches. The software application successfully linked and de-duplicated 7 million records across 6 institutions, resulting in a cohort of 5 million unique records. Using a manually reconciled set of 11 292 patients as a gold standard, the software achieved a sensitivity of 96% and a specificity of 100%, with a majority of the missed matches accounted for by patients with both a missing social security number and last name change. Using 3 disease examples, it is demonstrated that the software can reduce duplication of patient records across sites by as much as 28%. Software that standardizes the assignment of a unique seeded hash identifier merged through an agreed upon third-party honest broker can enable large-scale secure linkage of EHR data for epidemiologic and public health research. The software algorithm can improve future epidemiologic research by providing more comprehensive data given that patients may make use of multiple healthcare systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Analyzing gene perturbation screens with nested effects models in R and bioconductor.

    PubMed

    Fröhlich, Holger; Beissbarth, Tim; Tresch, Achim; Kostka, Dennis; Jacob, Juby; Spang, Rainer; Markowetz, F

    2008-11-01

    Nested effects models (NEMs) are a class of probabilistic models introduced to analyze the effects of gene perturbation screens visible in high-dimensional phenotypes like microarrays or cell morphology. NEMs reverse engineer upstream/downstream relations of cellular signaling cascades. NEMs take as input a set of candidate pathway genes and phenotypic profiles of perturbing these genes. NEMs return a pathway structure explaining the observed perturbation effects. Here, we describe the package nem, an open-source software to efficiently infer NEMs from data. Our software implements several search algorithms for model fitting and is applicable to a wide range of different data types and representations. The methods we present summarize the current state-of-the-art in NEMs. Our software is written in the R language and freely avail-able via the Bioconductor project at http://www.bioconductor.org.

  2. 28 CFR 904.1 - Purpose and authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...

  3. 28 CFR 904.1 - Purpose and authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...

  4. 28 CFR 904.1 - Purpose and authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...

  5. 28 CFR 904.1 - Purpose and authority.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...

  6. 28 CFR 904.1 - Purpose and authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...

  7. Exploring attitudes and preferences for dementia screening in Britain: contributions from carers and the general public.

    PubMed

    Martin, Steven; Fleming, Jane; Cullum, Sarah; Dening, Tom; Rait, Greta; Fox, Chris; Katona, Cornelius; Brayne, Carol; Lafortune, Louise

    2015-09-09

    Dementia is becoming one of the most important emerging public health concerns in a generation. In societal approaches to the mitigation of major disease 'burden', population screening can sometimes provide an effective approach to improving detection of disease and outcomes. However the acceptability of a systematic population screening programme for dementia, to the British public, is not known. A Patient and Public Involvement (PPI) event was organised to give members of the public from the East of England an opportunity to offer their perspectives and to comment on the findings of a systematic literature review looking at attitudes and preferences towards screening for dementia. The event was attended by 36 members of the public and eight national Alzheimer's Society Research Network volunteers. The morning discussion contained a presentation, which defined population screening for attendees but contained no reference to the findings of the review. In the afternoon, findings of the review were presented and a discussion on the results was facilitated. The discussions were recorded, transcribed and subjected to thematic analysis. The NVivo qualitative data software was used to facilitate this process. A total of 23 key themes emerged in relation to the carer and general population. The most frequent themes which emerged were the low levels of understanding and awareness around the dementia syndrome; the acceptability and validity of any tests; costs to the National Health Service (NHS); an individual's existing health status existing health status; financial/profit motive for screening; the inability to change prognosis; and the importance and availability of support. Factors such as personal beliefs, experiences and attitudes to health impact on decisions to be screened for dementia. A number of additional concerns were raised which were not previously identified in the systematic literature review. These were around the economic incentives for screening (profit motive), the provision of social support, and the economic/social impacts of screening programmes. This may reflect cultural differences in health and social care funding models between Britain and other countries where previous research was conducted.

  8. Software Engineering Laboratory Series: Proceedings of the Twentieth Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  9. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 15

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  10. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 14

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  11. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 13

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  12. Risk factors and distribution of oncogenic strains of human papilloma virus in women presenting for cervical cancer screening in Port Harcourt, Nigeria.

    PubMed

    Kennedy, Nyengidiki Tamunomie; Ikechukwu, Durugbo; Goddy, Bassey

    2016-01-01

    Human papilloma virus(HPV) accounts for most cases of cervical cancer with high risk HPV(hrHPV) genotypes largely responsible. The objective is to ascertain the distribution of oncogenic strains of human papilloma virus genotypes and predisposing risk factors in women presenting for cervical cancer screening in Nigeria. A cross-sectional study of 80 women who presented for cervical cancer screening. The biodata of the participants, the presence of risk factors to HPV were recorded and hrHPV were identified using PCR technique. The information obtained was processed using the SPSS version 20 software. Results were presented in tables, test of significance and association done using student's t-test and Odds ratio, with P value < 0.05 as significant. The age range of patients was 19-62 years with prevalence of hrHPV of 10%. HrHPV are more in patients with more than one life time sexual partner (OR 1.26,95%CI 0.13-29.99), multiple sexual partners (OR 1.55, 95% CI 0.28-8.70), early coitarche (OR 1.57, 95% CI 0.14-15.00) and previous STI (OR 150, 95%CI 9.53-1979. 62). Four hrHPV genotypes: 16, 18, 31 and 35 were detected. HPV genotype 18 was predominant in Port Harcourt, Nigeria. High risk sexual behaviours are associated with acquisition of hrHPV.

  13. Giga-pixel fluorescent imaging over an ultra-large field-of-view using a flatbed scanner.

    PubMed

    Göröcs, Zoltán; Ling, Yuye; Yu, Meng Dai; Karahalios, Dimitri; Mogharabi, Kian; Lu, Kenny; Wei, Qingshan; Ozcan, Aydogan

    2013-11-21

    We demonstrate a new fluorescent imaging technique that can screen for fluorescent micro-objects over an ultra-wide field-of-view (FOV) of ~532 cm(2), i.e., 19 cm × 28 cm, reaching a space-bandwidth product of more than 2 billion. For achieving such a large FOV, we modified the hardware and software of a commercially available flatbed scanner, and added a custom-designed absorbing fluorescent filter, a two-dimensional array of external light sources for computer-controlled and high-angle fluorescent excitation. We also re-programmed the driver of the scanner to take full control of the scanner hardware and achieve the highest possible exposure time, gain and sensitivity for detection of fluorescent micro-objects through the gradient index self-focusing lens array that is positioned in front of the scanner sensor chip. For example, this large FOV of our imaging platform allows us to screen more than 2.2 mL of undiluted whole blood for detection of fluorescent micro-objects within <5 minutes. This high-throughput fluorescent imaging platform could be useful for rare cell research and cytometry applications by enabling rapid screening of large volumes of optically dense media. Our results constitute the first time that a flatbed scanner has been converted to a fluorescent imaging system, achieving a record large FOV.

  14. A Computer Supported Teamwork Project for People with a Visual Impairment.

    ERIC Educational Resources Information Center

    Hale, Greg

    2000-01-01

    Discussion of the use of computer supported teamwork (CSTW) in team-based organizations focuses on problems that visually impaired people have reading graphical user interface software via screen reader software. Describes a project that successfully used email for CSTW, and suggests issues needing further research. (LRW)

  15. Influence of Smartphones and Software on Acoustic Voice Measures

    PubMed Central

    GRILLO, ELIZABETH U.; BROSIOUS, JENNA N.; SORRELL, STACI L.; ANAND, SUPRAJA

    2016-01-01

    This study assessed the within-subject variability of voice measures captured using different recording devices (i.e., smartphones and head mounted microphone) and software programs (i.e., Analysis of Dysphonia in Speech and Voice (ADSV), Multi-dimensional Voice Program (MDVP), and Praat). Correlations between the software programs that calculated the voice measures were also analyzed. Results demonstrated no significant within-subject variability across devices and software and that some of the measures were highly correlated across software programs. The study suggests that certain smartphones may be appropriate to record daily voice measures representing the effects of vocal loading within individuals. In addition, even though different algorithms are used to compute voice measures across software programs, some of the programs and measures share a similar relationship. PMID:28775797

  16. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    PubMed

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  17. Does sharing the electronic health record in the consultation enhance patient involvement? A mixed-methods study using multichannel video recording and in-depth interviews in primary care.

    PubMed

    Milne, Heather; Huby, Guro; Buckingham, Susan; Hayward, James; Sheikh, Aziz; Cresswell, Kathrin; Pinnock, Hilary

    2016-06-01

    Sharing the electronic health-care record (EHR) during consultations has the potential to facilitate patient involvement in their health care, but research about this practice is limited. We used multichannel video recordings to identify examples and examine the practice of screen-sharing within 114 primary care consultations. A subset of 16 consultations was viewed by the general practitioner and/or patient in 26 reflexive interviews. Screen-sharing emerged as a significant theme and was explored further in seven additional patient interviews. Final analysis involved refining themes from interviews and observation of videos to understand how screen-sharing occurred, and its significance to patients and professionals. Eighteen (16%) of 114 videoed consultations involved instances of screen-sharing. Screen-sharing occurred in six of the subset of 16 consultations with interviews and was a significant theme in 19 of 26 interviews. The screen was shared in three ways: 'convincing' the patient of a diagnosis or treatment; 'translating' between medical and lay understandings of disease/medication; and by patients 'verifying' the accuracy of the EHR. However, patients and most GPs perceived the screen as the doctor's domain, not to be routinely viewed by the patient. Screen-sharing can facilitate patient involvement in the consultation, depending on the way in which sharing comes about, but the perception that the record belongs to the doctor is a barrier. To exploit the potential of sharing the screen to promote patient involvement, there is a need to reconceptualise and redesign the EHR. © 2014 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  18. Cockpit Ocular Recording System (CORS)

    NASA Technical Reports Server (NTRS)

    Rothenheber, Edward; Stokes, James; Lagrossa, Charles; Arnold, William; Dick, A. O.

    1990-01-01

    The overall goal was the development of a Cockpit Ocular Recording System (CORS). Four tasks were used: (1) the development of the system; (2) the experimentation and improvement of the system; (3) demonstrations of the working system; and (4) system documentation. Overall, the prototype represents a workable and flexibly designed CORS system. For the most part, the hardware use for the prototype system is off-the-shelf. All of the following software was developed specifically: (1) setup software that the user specifies the cockpit configuration and identifies possible areas in which the pilot will look; (2) sensing software which integrates the 60 Hz data from the oculometer and heat orientation sensing unit; (3) processing software which applies a spatiotemporal filter to the lookpoint data to determine fixation/dwell positions; (4) data recording output routines; and (5) playback software which allows the user to retrieve and analyze the data. Several experiments were performed to verify the system accuracy and quantify system deficiencies. These tests resulted in recommendations for any future system that might be constructed.

  19. A real-time detector system for precise timing of audiovisual stimuli.

    PubMed

    Henelius, Andreas; Jagadeesan, Sharman; Huotilainen, Minna

    2012-01-01

    The successful recording of neurophysiologic signals, such as event-related potentials (ERPs) or event-related magnetic fields (ERFs), relies on precise information of stimulus presentation times. We have developed an accurate and flexible audiovisual sensor solution operating in real-time for on-line use in both auditory and visual ERP and ERF paradigms. The sensor functions independently of the used audio or video stimulus presentation tools or signal acquisition system. The sensor solution consists of two independent sensors; one for sound and one for light. The microcontroller-based audio sensor incorporates a novel approach to the detection of natural sounds such as multipart audio stimuli, using an adjustable dead time. This aids in producing exact markers for complex auditory stimuli and reduces the number of false detections. The analog photosensor circuit detects changes in light intensity on the screen and produces a marker for changes exceeding a threshold. The microcontroller software for the audio sensor is free and open source, allowing other researchers to customise the sensor for use in specific auditory ERP/ERF paradigms. The hardware schematics and software for the audiovisual sensor are freely available from the webpage of the authors' lab.

  20. PRISM Software: Processing and Review Interface for Strong‐Motion Data

    USGS Publications Warehouse

    Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter

    2017-01-01

    A continually increasing number of high‐quality digital strong‐motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey, as well as data from regional seismic networks within the United States, calls for automated processing of strong‐motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong‐motion records. When used without AQMS, PRISM provides batch‐processing capabilities. The PRISM software is platform independent (coded in Java), open source, and does not depend on any closed‐source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a review tool, which is a graphical user interface for manual review, edit, and processing. To facilitate use by non‐NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand‐alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible to accommodate implementation of new processing techniques. All the computing features have been thoroughly tested.

  1. Self-Report Versus Medical Record for Mammography Screening Among Minority Women.

    PubMed

    Nandy, Karabi; Menon, Usha; Szalacha, Laura A; Park, HanJong; Lee, Jongwon; Lee, Eunice E

    2016-12-01

    Self-report is the most common means of obtaining mammography screening data. The purpose of this study was to assess the accuracy of minority women's self-reported mammography by comparing their self-reported dates of mammograms with those in their medical records from a community-based randomized control trial. We found that out of 192 women, 116 signed the Health Information Portability and Accountability Act form and, among these, 97 had medical records that could be verified (97 / 116 = 83.6%). Ninety-two records matched where both sources confirmed a mammogram; 48 of 92 (52.2%) matched perfectly on self-reported date of mammogram. Complexities in the verification process warrant caution when verifying self-reported mammography screening in minority populations. In spite of some limitations, our findings support the usage of self-reported data on mammography as a validated tool for other researchers investigating mammography screening among minority women who continue to have low screening rates. © The Author(s) 2016.

  2. Database Access Manager for the Software Engineering Laboratory (DAMSEL) user's guide

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Operating instructions for the Database Access Manager for the Software Engineering Laboratory (DAMSEL) system are presented. Step-by-step instructions for performing various data entry and report generation activities are included. Sample sessions showing the user interface display screens are also included. Instructions for generating reports are accompanied by sample outputs for each of the reports. The document groups the available software functions by the classes of users that may access them.

  3. Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.

    PubMed

    Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne

    2014-08-01

    To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.

  4. The agreement between self-reported cervical smear abnormalities and screening programme records.

    PubMed

    Canfell, Karen; Beral, Valerie; Green, Jane; Cameron, Rebecca; Baker, Krys; Brown, Anna

    2006-01-01

    The Million Women Study is a cohort study of women aged 50-64 years in England and Scotland. As a component of the follow-up questionnaire, participants were asked to indicate if they had an abnormal cervical smear in the previous five years. This study compared self-reported cervical abnormalities with screening records obtained from the National Health Service Cervical Screening Programme. For 1944 randomly selected Million Women Study participants in Oxfordshire, screening records were assessed over a six-year period prior to the date of self-reporting. The six-year period was chosen to allow for errors in the recall of timing of abnormal smears. A total of 68 women (3.5%) had a record of at least one equivocal or abnormal smear within the last six years, whereas 49 women (2.5%) self-reported an abnormality. There was a strong trend for an increased probability of self-reporting a history of an abnormal smear as the severity of the recorded abnormality increased (P <0.001). For women with an NHS record of borderline dyskaryosis, mild dyskaryosis, or moderate dyskaryosis/severe dyskaryosis/invasive cancer, the proportions reporting an abnormality were 40%, 58% and 77%, respectively. For women with negative and inadequate smears, the proportion self-reporting an abnormality were 0.6% and 0.7%, respectively. These results indicate that among women whose screening programme records show an abnormal smear, the proportion self-reporting an abnormality increases with the severity of the recorded lesion. Almost all women with a record of negative or inadequate smear(s) correctly interpret the result and do not self-report an abnormality.

  5. Software Engineering Laboratory Series: Proceedings of the Twenty-First Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  6. Software Engineering Laboratory Series: Proceedings of the Twenty-Second Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  7. Water Distribution System Risk Tool for Investment Planning (WaterRF Report 4332)

    EPA Science Inventory

    Product Description/Abstract The product consists of the Pipe Risk Screening Tool (PRST), and a report on the development and use of the tool. The PRST is a software-based screening aid to identify and rank candidate pipes for actions that range from active monitoring (including...

  8. Touch Screen Tablets and Emergent Literacy

    ERIC Educational Resources Information Center

    Neumann, Michelle M.; Neumann, David L.

    2014-01-01

    The use of touch screen tablets by young children is increasing in the home and in early childhood settings. The simple tactile interface and finger-based operating features of tablets may facilitate preschoolers' use of tablet application software and support their educational development in domains such as literacy. This article reviews…

  9. 78 FR 78751 - Medicare Program; Physicians' Referrals to Health Care Entities With Which They Have Financial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... records software or information technology and training services. The final rule for this exception was... involving interoperable electronic health records software or information technology and training services... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services 42 CFR Part 411...

  10. Activation of a medical emergency team using an electronic medical recording-based screening system*.

    PubMed

    Huh, Jin Won; Lim, Chae-Man; Koh, Younsuck; Lee, Jury; Jung, Youn-Kyung; Seo, Hyun-Suk; Hong, Sang-Bum

    2014-04-01

    To evaluate the efficacy of a medical emergency team activated using 24-hour monitoring by electronic medical record-based screening criteria followed by immediate intervention by a skilled team. Retrospective cohort study. Academic tertiary care hospital with approximately 2,700 beds. A total of 3,030 events activated by a medical emergency team from March 1, 2008, to February 28, 2010. None. We collected data for all medical emergency team activations: patient characteristics, trigger type for medical emergency team (electronic medical record-based screening vs calling criteria), interventions during each event, outcomes of the medical emergency team intervention, and 28-day mortality after medical emergency team activation. We analyzed data for 2009, when the medical emergency team functioned 24 hours a day, 7 days a week (period 2), compared with that for 2008, when the medical emergency team functioned 12 hours a day, 7 days a week (period 1). The commonest cause of medical emergency team activation was respiratory distress (43.6%), and the medical emergency team performed early goal-directed therapy (21.3%), respiratory care (19.9%), and difficult airway management (12.3%). For patients on general wards, 51.3% (period 1) and 38.4% (period 2) of medical emergency team activations were triggered by the electronic medical record-based screening system (electronic medical record-triggered group). In 23.4%, activation occurred because of an abnormality in laboratory screening criteria. The commonest activation criterion from electronic medical record-based screening was respiratory rate (39.4%). Over half the patients were treated in the general ward, and one third of the patients were transferred to the ICU. The electronic medical record-triggered group had lower ICU admission with an odds ratio of 0.35 (95% CI, 0.22-0.55). In surgical patients, the electronic medical record-triggered group showed the lower 28-day mortality (10.5%) compared with the call-triggered group (26.7%) or the double-triggered group (33.3%) (odds ratio 0.365 with 95% CI, 0.154-0.867, p = 0.022). We successful managed the medical emergency team with electronic medical record-based screening criteria and a skilled intervention team. The electronic medical record-triggered group had lower ICU admission than the call-triggered group or the double-triggered group. In surgical patients, the electronic medical record-triggered group showed better outcome than other groups.

  11. Fluorescent screens and image processing for the APS linac test stand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, W.; Ko, K.

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image processing will also be discussed.

  12. [CompuRecord--A perioperative information management-system for anesthesia].

    PubMed

    Martin, J; Ederle, D; Milewski, P

    2002-08-01

    Since 1977 procedures for automatic documentation of anesthesias have repeatedly been described. Because of a limited arrangement of the desk top and because of its focussing on intraoperative documentation only a widespread introduction could not be established so far. Todays systems are offered with graphically orientated desktops which can be operated by intuition. The CompuRecord(R)-System (Philips Healthcare) is a perioperative management system for anaesthesia. It is constructed with modular components, recording the complete anaesthesiological care of a patient from preanaesthesiological assessment to the recovery room. Additional modules allow an economical check, provide for quality management and exportation of a core data base. Except for the original software all other components of the system including the net work components are IT standard products allowing reduced costs for supplementation, expansion and support. The advantage of an automatical documentation system of anaesthesia is frequent and detailed recording of anaesthesiological data as well as the possibility of a meticulous calculation of cost for each patient. The anaesthesiologist's time used for documentation is reduced remarkably with a limited and reasonable amount of data to be recorded. This leaves more time of attention for the patient himself. Time necessary for training is kept low with the touch screens of the CompuRecord(R) - System, which can be operated intuitively. Primary to purchase an exact analysis of process and of subsequent costs should be done. Standardized documentation allows to establish Standard Operating Procedures in a department of Anaesthesia. Using the given systems an implementation is possible already today despite restricted resources of man power.

  13. The effect of electronic health record software design on resident documentation and compliance with evidence-based medicine.

    PubMed

    Rodriguez Torres, Yasaira; Huang, Jordan; Mihlstin, Melanie; Juzych, Mark S; Kromrei, Heidi; Hwang, Frank S

    2017-01-01

    This study aimed to determine the role of electronic health record software in resident education by evaluating documentation of 30 elements extracted from the American Academy of Ophthalmology Dry Eye Syndrome Preferred Practice Pattern. The Kresge Eye Institute transitioned to using electronic health record software in June 2013. We evaluated the charts of 331 patients examined in the resident ophthalmology clinic between September 1, 2011, and March 31, 2014, for an initial evaluation for dry eye syndrome. We compared documentation rates for the 30 evidence-based elements between electronic health record chart note templates among the ophthalmology residents. Overall, significant changes in documentation occurred when transitioning to a new version of the electronic health record software with average compliance ranging from 67.4% to 73.6% (p < 0.0005). Electronic Health Record A had high compliance (>90%) in 13 elements while Electronic Health Record B had high compliance (>90%) in 11 elements. The presence of dialog boxes was responsible for significant changes in documentation of adnexa, puncta, proptosis, skin examination, contact lens wear, and smoking exposure. Significant differences in documentation were correlated with electronic health record template design rather than individual resident or residents' year in training. Our results show that electronic health record template design influences documentation across all resident years. Decreased documentation likely results from "mouse click fatigue" as residents had to access multiple dialog boxes to complete documentation. These findings highlight the importance of EHR template design to improve resident documentation and integration of evidence-based medicine into their clinical notes.

  14. Molecular modeling, simulation and virtual screening of MurD ligase protein from Salmonella typhimurium LT2.

    PubMed

    Samal, Himanshu Bhusan; Das, Jugal Kishore; Mahapatra, Rajani Kanta; Suar, Mrutyunjay

    2015-01-01

    The Mur enzymes of the peptidoglycan biosynthesis pathway constitute ideal targets for the design of new classes of antimicrobial inhibitors in Gram-negative bacteria. We built a homology model of MurD of Salmonella typhimurium LT2 using MODELLER (9v12) software. 'The homology model was subjected to energy minimization by molecular dynamics (MD) simulation study with GROMACS software for a simulation time of 20 ns in water environment. The model was subjected for virtual screening study from the Zinc Database using Dockblaster software. Inhibition assay for the best inhibitor, 3-(amino methyl)-n-(4-methoxyphenyl) aniline, by flow cytometric analysis revealed the effective inhibition of peptidoglycan biosynthesis. Results from this study provide new insights for the molecular understanding and development of new antibacterial drugs against the pathogen. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Diabetic Retinopathy Screening and Monitoring of Early Stage Disease in Australian General Practice: Tackling Preventable Blindness within a Chronic Care Model.

    PubMed

    Crossland, Lisa; Askew, Deborah; Ware, Robert; Cranstoun, Peter; Mitchell, Paul; Bryett, Andrew; Jackson, Claire

    2016-01-01

    Diabetic retinopathy (DR) is the leading cause of preventable blindness in Australia. Up to 50% of people with proliferative DR who do not receive timely treatment will become legally blind within five years. Innovative and accessible screening, involving a variety of primary care providers, will become increasingly important if patients with diabetes are to receive optimal eye care. An open controlled trial design was used. Five intervention practices in urban, regional, and rural Australia partnered with ophthalmologists via telehealth undertook DR screening and monitoring of type 2 diabetes patients and were compared with control practices undertaking usual care 2011-2014. Recorded screening rates were 100% across intervention practices, compared with 22-53% in control practices. 31/577 (5%) of patients in the control practices were diagnosed with mild-moderate DR, of whom 9 (29%) had appropriate follow-up recorded. This was compared with 39/447 (9%) of patients in the intervention group, of whom 37 (95%) had appropriate follow-up recorded. General practice-based DR screening via Annual Cycle of Care arrangements is effective across differing practice locations. It offers improved recording of screening outcomes for Australians with type 2 diabetes and better follow-up of those with screen abnormalities.

  16. Real time computer data system for the 40 x 80 ft wind tunnel facility at Ames Research Center

    NASA Technical Reports Server (NTRS)

    Cambra, J. M.; Tolari, G. P.

    1974-01-01

    The wind tunnel realtime computer system is a distributed data gathering system that features a master computer subsystem, a high speed data gathering subsystem, a quick look dynamic analysis and vibration control subsystem, an analog recording back-up subsystem, a pulse code modulation (PCM) on-board subsystem, a communications subsystem, and a transducer excitation and calibration subsystem. The subsystems are married to the master computer through an executive software system and standard hardware and FORTRAN software interfaces. The executive software system has four basic software routines. These are the playback, setup, record, and monitor routines. The standard hardware interfaces along with the software interfaces provide the system with the capability of adapting to new environments.

  17. Usability and utility evaluation of the web-based "Should I Start Insulin?" patient decision aid for patients with type 2 diabetes among older people.

    PubMed

    Lee, Yew Kong; Lee, Ping Yein; Ng, Chirk Jenn; Teo, Chin Hai; Abu Bakar, Ahmad Ihsan; Abdullah, Khatijah Lim; Khoo, Ee Ming; Hanafi, Nik Sherina; Low, Wah Yun; Chiew, Thiam Kian

    2018-01-01

    This study aimed to evaluate the usability (ease of use) and utility (impact on user's decision-making process) of a web-based patient decision aid (PDA) among older-age users. A pragmatic, qualitative research design was used. We recruited patients with type 2 diabetes who were at the point of making a decision about starting insulin from a tertiary teaching hospital in Malaysia in 2014. Computer screen recording software was used to record the website browsing session and in-depth interviews were conducted while playing back the website recording. The interviews were analyzed using the framework approach to identify usability and utility issues. Three cycles of iteration were conducted until no more major issues emerged. Thirteen patients participated: median age 65 years old, 10 men, and nine had secondary education/diploma, four were graduates/had postgraduate degree. Four usability issues were identified (navigation between pages and sections, a layout with open display, simple language, and equipment preferences). For utility, participants commented that the website influenced their decision about insulin in three ways: it had provided information about insulin, it helped them deliberate choices using the option-attribute matrix, and it allowed them to involve others in their decision making by sharing the PDA summary printout.

  18. ZebraBeat: a flexible platform for the analysis of the cardiac rate in zebrafish embryos

    NASA Astrophysics Data System (ADS)

    de Luca, Elisa; Zaccaria, Gian Maria; Hadhoud, Marwa; Rizzo, Giovanna; Ponzini, Raffaele; Morbiducci, Umberto; Santoro, Massimo Mattia

    2014-05-01

    Heartbeat measurement is important in assesssing cardiac function because variations in heart rhythm can be the cause as well as an effect of hidden pathological heart conditions. Zebrafish (Danio rerio) has emerged as one of the most useful model organisms for cardiac research. Indeed, the zebrafish heart is easily accessible for optical analyses without conducting invasive procedures and shows anatomical similarity to the human heart. In this study, we present a non-invasive, simple, cost-effective process to quantify the heartbeat in embryonic zebrafish. To achieve reproducibility, high throughput and flexibility (i.e., adaptability to any existing confocal microscope system and with a user-friendly interface that can be easily used by researchers), we implemented this method within a software program. We show here that this platform, called ZebraBeat, can successfully detect heart rate variations in embryonic zebrafish at various developmental stages, and it can record cardiac rate fluctuations induced by factors such as temperature and genetic- and chemical-induced alterations. Applications of this methodology may include the screening of chemical libraries affecting heart rhythm and the identification of heart rhythm variations in mutants from large-scale forward genetic screens.

  19. Educational Software Employing Group Competition Using an Interactive Electronic Whiteboard

    ERIC Educational Resources Information Center

    Otsuki, Yoko; Bandoh, Hirokazu; Kato, Naoki; Indurkhya, Bipin; Nakagawa, Masaki

    2004-01-01

    This article presents a design of educational software employing group competition using a large interactive electronic whiteboard, and a report on its experimental use. Group competition and collaboration are useful methods to cultivate originality and communication skills. To share the same space, the same large screen, and face-to-face…

  20. Designing Better Camels: Developing Effective Documentation for Computer Software.

    ERIC Educational Resources Information Center

    Zacher, Candace M.

    This guide to the development of effective documentation for users of computer software begins by identifying five types of documentation, i.e., training manuals, user guides, tutorials, on-screen help comments, and troubleshooting manuals. Six steps in the development process are then outlined and briefly described: (1) planning and preparation;…

  1. Captivate MenuBuilder: Creating an Online Tutorial for Teaching Software

    ERIC Educational Resources Information Center

    Yelinek, Kathryn; Tarnowski, Lynn; Hannon, Patricia; Oliver, Susan

    2008-01-01

    In this article, the authors, students in an instructional technology graduate course, describe a process to create an online tutorial for teaching software. They created the tutorial for a cyber school's use. Five tutorial modules were linked together through one menu screen using the MenuBuilder feature in the Adobe Captivate program. The…

  2. Software Graphical User Interface For Analysis Of Images

    NASA Technical Reports Server (NTRS)

    Leonard, Desiree M.; Nolf, Scott R.; Avis, Elizabeth L.; Stacy, Kathryn

    1992-01-01

    CAMTOOL software provides graphical interface between Sun Microsystems workstation and Eikonix Model 1412 digitizing camera system. Camera scans and digitizes images, halftones, reflectives, transmissives, rigid or flexible flat material, or three-dimensional objects. Users digitize images and select from three destinations: work-station display screen, magnetic-tape drive, or hard disk. Written in C.

  3. CD Recorders.

    ERIC Educational Resources Information Center

    Falk, Howard

    1998-01-01

    Discussion of CD (compact disc) recorders describes recording applications, including storing large graphic files, creating audio CDs, and storing material downloaded from the Internet; backing up files; lifespan; CD recording formats; continuous recording; recording software; recorder media; vulnerability of CDs; basic computer requirements; and…

  4. Fragment-Based Docking: Development of the CHARMMing Web User Interface as a Platform for Computer-Aided Drug Design

    PubMed Central

    2015-01-01

    Web-based user interfaces to scientific applications are important tools that allow researchers to utilize a broad range of software packages with just an Internet connection and a browser.1 One such interface, CHARMMing (CHARMM interface and graphics), facilitates access to the powerful and widely used molecular software package CHARMM. CHARMMing incorporates tasks such as molecular structure analysis, dynamics, multiscale modeling, and other techniques commonly used by computational life scientists. We have extended CHARMMing’s capabilities to include a fragment-based docking protocol that allows users to perform molecular docking and virtual screening calculations either directly via the CHARMMing Web server or on computing resources using the self-contained job scripts generated via the Web interface. The docking protocol was evaluated by performing a series of “re-dockings” with direct comparison to top commercial docking software. Results of this evaluation showed that CHARMMing’s docking implementation is comparable to many widely used software packages and validates the use of the new CHARMM generalized force field for docking and virtual screening. PMID:25151852

  5. Fragment-based docking: development of the CHARMMing Web user interface as a platform for computer-aided drug design.

    PubMed

    Pevzner, Yuri; Frugier, Emilie; Schalk, Vinushka; Caflisch, Amedeo; Woodcock, H Lee

    2014-09-22

    Web-based user interfaces to scientific applications are important tools that allow researchers to utilize a broad range of software packages with just an Internet connection and a browser. One such interface, CHARMMing (CHARMM interface and graphics), facilitates access to the powerful and widely used molecular software package CHARMM. CHARMMing incorporates tasks such as molecular structure analysis, dynamics, multiscale modeling, and other techniques commonly used by computational life scientists. We have extended CHARMMing's capabilities to include a fragment-based docking protocol that allows users to perform molecular docking and virtual screening calculations either directly via the CHARMMing Web server or on computing resources using the self-contained job scripts generated via the Web interface. The docking protocol was evaluated by performing a series of "re-dockings" with direct comparison to top commercial docking software. Results of this evaluation showed that CHARMMing's docking implementation is comparable to many widely used software packages and validates the use of the new CHARMM generalized force field for docking and virtual screening.

  6. Ligand-based virtual screening and inductive learning for identification of SIRT1 inhibitors in natural products.

    PubMed

    Sun, Yunan; Zhou, Hui; Zhu, Hongmei; Leung, Siu-wai

    2016-01-25

    Sirtuin 1 (SIRT1) is a nicotinamide adenine dinucleotide-dependent deacetylase, and its dysregulation can lead to ageing, diabetes, and cancer. From 346 experimentally confirmed SIRT1 inhibitors, an inhibitor structure pattern was generated by inductive logic programming (ILP) with DMax Chemistry Assistant software. The pattern contained amide, amine, and hetero-aromatic five-membered rings, each of which had a hetero-atom and an unsubstituted atom at a distance of 2. According to this pattern, a ligand-based virtual screening of 1 444 880 active compounds from Chinese herbs identified 12 compounds as inhibitors of SIRT1. Three compounds (ZINC08790006, ZINC08792229, and ZINC08792355) had high affinity (-7.3, -7.8, and -8.6 kcal/mol, respectively) for SIRT1 as estimated by molecular docking software AutoDock Vina. This study demonstrated a use of ILP and background knowledge in machine learning to facilitate virtual screening.

  7. Ligand-based virtual screening and inductive learning for identification of SIRT1 inhibitors in natural products

    NASA Astrophysics Data System (ADS)

    Sun, Yunan; Zhou, Hui; Zhu, Hongmei; Leung, Siu-Wai

    2016-01-01

    Sirtuin 1 (SIRT1) is a nicotinamide adenine dinucleotide-dependent deacetylase, and its dysregulation can lead to ageing, diabetes, and cancer. From 346 experimentally confirmed SIRT1 inhibitors, an inhibitor structure pattern was generated by inductive logic programming (ILP) with DMax Chemistry Assistant software. The pattern contained amide, amine, and hetero-aromatic five-membered rings, each of which had a hetero-atom and an unsubstituted atom at a distance of 2. According to this pattern, a ligand-based virtual screening of 1 444 880 active compounds from Chinese herbs identified 12 compounds as inhibitors of SIRT1. Three compounds (ZINC08790006, ZINC08792229, and ZINC08792355) had high affinity (-7.3, -7.8, and -8.6 kcal/mol, respectively) for SIRT1 as estimated by molecular docking software AutoDock Vina. This study demonstrated a use of ILP and background knowledge in machine learning to facilitate virtual screening.

  8. Combinatorial electrochemical synthesis and screening of Pt-WO3 catalysts for electro-oxidation of methanol

    NASA Astrophysics Data System (ADS)

    Jayaraman, Shrisudersan; Baeck, Sung-Hyeon; Jaramillo, Thomas F.; Kleiman-Shwarsctein, Alan; McFarland, Eric W.

    2005-06-01

    An automated system for high-throughput electrochemical synthesis and screening of fuel cell electro-oxidation catalysts is described. This system consists of an electrode probe that contains counter and reference electrodes that can be positioned inside an array of electrochemical cells created within a polypropylene block. The electrode probe is attached to an automated of X-Y-Z motion system. An externally controlled potentiostat is used to apply the electrochemical potential to the catalyst substrate. The motion and electrochemical control are integrated using a user-friendly software interface. During automated synthesis the deposition potential and/or current may be controlled by a pulse program triggered by the software using a data acquisition board. The screening includes automated experiments to obtain cyclic voltammograms. As an example, a platinum-tungsten oxide (Pt-WO3) library was synthesized and characterized for reactivity towards methanol electro-oxidation.

  9. Localization-based super-resolution imaging meets high-content screening.

    PubMed

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  10. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  11. Nine Easy Steps to Avoiding Software Copyright Infringement.

    ERIC Educational Resources Information Center

    Gamble, Lanny R.; Anderson, Larry S.

    1989-01-01

    To avoid microcomputer software copyright infringement, administrators must be aware of the law, read the software agreements, maintain good records, submit all software registration cards, provide secure storage, post warnings, be consistent when establishing and enforcing policies, consider a site license, and ensure the legality of currently…

  12. Evaluation of a novel electronic genetic screening and clinical decision support tool in prenatal clinical settings.

    PubMed

    Edelman, Emily A; Lin, Bruce K; Doksum, Teresa; Drohan, Brian; Edelson, Vaughn; Dolan, Siobhan M; Hughes, Kevin; O'Leary, James; Vasquez, Lisa; Copeland, Sara; Galvin, Shelley L; DeGroat, Nicole; Pardanani, Setul; Gregory Feero, W; Adams, Claire; Jones, Renee; Scott, Joan

    2014-07-01

    "The Pregnancy and Health Profile" (PHP) is a free prenatal genetic screening and clinical decision support (CDS) software tool for prenatal providers. PHP collects family health history (FHH) during intake and provides point-of-care risk assessment for providers and education for patients. This pilot study evaluated patient and provider responses to PHP and effects of using PHP in practice. PHP was implemented in four clinics. Surveys assessed provider confidence and knowledge and patient and provider satisfaction with PHP. Data on the implementation process were obtained through semi-structured interviews with administrators. Quantitative survey data were analyzed using Chi square test, Fisher's exact test, paired t tests, and multivariate logistic regression. Open-ended survey questions and interviews were analyzed using qualitative thematic analysis. Of the 83% (513/618) of patients that provided feedback, 97% felt PHP was easy to use and 98% easy to understand. Thirty percent (21/71) of participating physicians completed both pre- and post-implementation feedback surveys [13 obstetricians (OBs) and 8 family medicine physicians (FPs)]. Confidence in managing genetic risks significantly improved for OBs on 2/6 measures (p values ≤0.001) but not for FPs. Physician knowledge did not significantly change. Providers reported value in added patient engagement and reported mixed feedback about the CDS report. We identified key steps, resources, and staff support required to implement PHP in a clinical setting. To our knowledge, this study is the first to report on the integration of patient-completed, electronically captured and CDS-enabled FHH software into primary prenatal practice. PHP is acceptable to patients and providers. Key to successful implementation in the future will be customization options and interoperability with electronic health records.

  13. Results obtained with a low cost software-based audiometer for hearing screening.

    PubMed

    Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis

    2013-07-01

     The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening.  To evaluate the TS audiometer for conducting audiometric screening.  A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated.  For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively.  The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

  14. Considerations for choosing an electronic medical record for an ophthalmology practice.

    PubMed

    DeBry, P W

    2001-04-01

    To give a brief overview of issues pertinent to selecting an ophthalmic electronic medical record (EMR) program and to outline the company demographics and software capabilities of the major vendors in this area. Software companies shipping an EMR package were contacted to obtain information on their software and company demographics. The focus was on companies selectively marketing to ophthalmology practices, and, therefore, most were selected based on their representation at the 1998 and/or 1999 American Academy of Ophthalmology meeting. Software companies that responded to repeated inquiries in a timely fashion were included. Sixteen companies were evaluated. Electronic medical records packages ranged from $3000 to $80 000 (mean, approximately $30 000). Company demographics revealed a range from 1 to 1600 employees (mean, 204). Most of these companies have been in business for 6 years or less (range, 1-15 years; mean, 6 years). My opinions concerning various aspects of the EMR are presented. There is a wide range of EMR products available for the ophthalmology practice. Computer technology has matured to a point at which the graphical demands of the ophthalmology EMR can be satisfied. Weaknesses do exist in the inherent difficulty of recording an ophthalmology encounter, the relative adolescence of software companies, and the lack of standards in the industry.

  15. ALSC 2011 Notable Videos, Recordings & Interactive Software

    ERIC Educational Resources Information Center

    School Library Journal, 2011

    2011-01-01

    This article presents the Notable Children's Videos, Recordings, and Interactive Software for Kids lists which are compiled annually by committees of the Association for Library Service to children (ALSC), a division of the American Library Association (ALA). These lists were released in January 2011 at the ALA Midwinter meeting in San Diego,…

  16. SignalPlant: an open signal processing software platform.

    PubMed

    Plesinger, F; Jurco, J; Halamek, J; Jurak, P

    2016-07-01

    The growing technical standard of acquisition systems allows the acquisition of large records, often reaching gigabytes or more in size as is the case with whole-day electroencephalograph (EEG) recordings, for example. Although current 64-bit software for signal processing is able to process (e.g. filter, analyze, etc) such data, visual inspection and labeling will probably suffer from rather long latency during the rendering of large portions of recorded signals. For this reason, we have developed SignalPlant-a stand-alone application for signal inspection, labeling and processing. The main motivation was to supply investigators with a tool allowing fast and interactive work with large multichannel records produced by EEG, electrocardiograph and similar devices. The rendering latency was compared with EEGLAB and proves significantly faster when displaying an image from a large number of samples (e.g. 163-times faster for 75  ×  10(6) samples). The presented SignalPlant software is available free and does not depend on any other computation software. Furthermore, it can be extended with plugins by third parties ensuring its adaptability to future research tasks and new data formats.

  17. Self-report versus Medical Records for Assessing Cancer-Preventive Services Delivery

    PubMed Central

    Ferrante, Jeanne M.; Ohman-Strickland, Pamela; Hahn, Karissa A.; Hudson, Shawna V.; Shaw, Eric K.; Crosson, Jesse C.; Crabtree, Benjamin F.

    2010-01-01

    Accurate measurement of cancer-preventive behaviors is important for quality improvement, research studies, and public health surveillance. Findings differ, however, depending on whether patient self-report or medical records are used as the data source. We evaluated concordance between patient self-report and medical records on risk factors, cancer screening, and behavioral counseling among primary care patients. Data from patient surveys and medical records were compared from 742 patients in 25 New Jersey primary care practices participating at baseline in SCOPE (supporting colorectal cancer outcomes through participatory enhancements), an intervention trial to improve colorectal cancer screening in primary care offices. Sensitivity, specificity, and rates of agreement describe concordance between self-report and medical records for risk factors (personal or family history of cancer, smoking), cancer screening (breast, cervical, colorectal, prostate), and counseling (cancer screening recommendations, diet or weight loss, exercise, smoking cessation). Rates of agreement ranged from 41% (smoking cessation counseling) to 96% (personal history of cancer). Cancer screening agreement ranged from 61% (Pap and prostate-specific antigen) to 83% (colorectal endoscopy) with self-report rates greater than medical record rates. Counseling was also reported more frequently by self-report (83% by patient self-report versus 34% by medical record for smoking cessation counseling). Deciding which data source to use will depend on the outcome of interest, whether the data is used for clinical decision making, performance tracking, or population surveillance; the availability of resources; and whether a false positive or a false negative is of more concern. PMID:18990740

  18. SpotMetrics: An Open-Source Image-Analysis Software Plugin for Automatic Chromatophore Detection and Measurement.

    PubMed

    Hadjisolomou, Stavros P; El-Haddad, George

    2017-01-01

    Coleoid cephalopods (squid, octopus, and sepia) are renowned for their elaborate body patterning capabilities, which are employed for camouflage or communication. The specific chromatic appearance of a cephalopod, at any given moment, is a direct result of the combined action of their intradermal pigmented chromatophore organs and reflecting cells. Therefore, a lot can be learned about the cephalopod coloration system by video recording and analyzing the activation of individual chromatophores in time. The fact that adult cephalopods have small chromatophores, up to several hundred thousand in number, makes measurement and analysis over several seconds a difficult task. However, current advancements in videography enable high-resolution and high framerate recording, which can be used to record chromatophore activity in more detail and accuracy in both space and time domains. In turn, the additional pixel information and extra frames per video from such recordings result in large video files of several gigabytes, even when the recording spans only few minutes. We created a software plugin, "SpotMetrics," that can automatically analyze high resolution, high framerate video of chromatophore organ activation in time. This image analysis software can track hundreds of individual chromatophores over several hundred frames to provide measurements of size and color. This software may also be used to measure differences in chromatophore activation during different behaviors which will contribute to our understanding of the cephalopod sensorimotor integration system. In addition, this software can potentially be utilized to detect numbers of round objects and size changes in time, such as eye pupil size or number of bacteria in a sample. Thus, we are making this software plugin freely available as open-source because we believe it will be of benefit to other colleagues both in the cephalopod biology field and also within other disciplines.

  19. Internet-Based Cervical Cancer Screening Program

    DTIC Science & Technology

    2008-05-01

    information technology have facilitated the Internet transmission and archival storage of digital images and other clinical information . The combination of...Phase included: 1) development of hardware, software, and interfaces between computerized scanning device and Internet - linked servers and reading...AD_________________ Award Number: W81XWH-04-C-0083 TITLE: Internet -Based Cervical Cancer Screening

  20. Capture Their Attention: Capturing Lessons Using Screen Capture Software

    ERIC Educational Resources Information Center

    Drumheller, Kristina; Lawler, Gregg

    2011-01-01

    When students miss classes for university activities such as athletic and academic events, they inevitably miss important class material. Students can get notes from their peers or visit professors to find out what they missed, but when students miss new and challenging material these steps are sometimes not enough. Screen capture and recording…

  1. Processing and review interface for strong motion data (PRISM) software, version 1.0.0—Methodology and automated processing

    USGS Publications Warehouse

    Jones, Jeanne; Kalkan, Erol; Stephens, Christopher

    2017-02-23

    A continually increasing number of high-quality digital strong-motion records from stations of the National Strong-Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the United States, call for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong-motion records. When used without AQMS, PRISM provides batch-processing capabilities. The PRISM version 1.0.0 is platform independent (coded in Java), open source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine and a review tool that has a graphical user interface (GUI) to manually review, edit, and process records. To facilitate use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible in order to accommodate new processing techniques. This report provides a thorough description and examples of the record processing features supported by PRISM. All the computing features of PRISM have been thoroughly tested.

  2. Automated documentation error detection and notification improves anesthesia billing performance.

    PubMed

    Spring, Stephen F; Sandberg, Warren S; Anupama, Shaji; Walsh, John L; Driscoll, William D; Raines, Douglas E

    2007-01-01

    Documentation of key times and events is required to obtain reimbursement for anesthesia services. The authors installed an information management system to improve record keeping and billing performance but found that a significant number of their records still could not be billed in a timely manner, and some records were never billed at all because they contained documentation errors. Computer software was developed that automatically examines electronic anesthetic records and alerts clinicians to documentation errors by alphanumeric page and e-mail. The software's efficacy was determined retrospectively by comparing billing performance before and after its implementation. Staff satisfaction with the software was assessed by survey. After implementation of this software, the percentage of anesthetic records that could never be billed declined from 1.31% to 0.04%, and the median time to correct documentation errors decreased from 33 days to 3 days. The average time to release an anesthetic record to the billing service decreased from 3.0+/-0.1 days to 1.1+/-0.2 days. More than 90% of staff found the system to be helpful and easier to use than the previous manual process for error detection and notification. This system allowed the authors to reduce the median time to correct documentation errors and the number of anesthetic records that were never billed by at least an order of magnitude. The authors estimate that these improvements increased their department's revenue by approximately $400,000 per year.

  3. Software tools for interactive instruction in radiologic anatomy.

    PubMed

    Alvarez, Antonio; Gold, Garry E; Tobin, Brian; Desser, Terry S

    2006-04-01

    To promote active learning in an introductory Radiologic Anatomy course through the use of computer-based exercises. DICOM datasets from our hospital PACS system were transferred to a networked cluster of desktop computers in a medical school classroom. Medical students in the Radiologic Anatomy course were divided into four small groups and assigned to work on a clinical case for 45 minutes. The groups used iPACS viewer software, a free DICOM viewer, to view images and annotate anatomic structures. The classroom instructor monitored and displayed each group's work sequentially on the master screen by running SynchronEyes, a software tool for controlling PC desktops remotely. Students were able to execute the assigned tasks using the iPACS software with minimal oversight or instruction. Course instructors displayed each group's work on the main display screen of the classroom as the students presented the rationale for their decisions. The interactive component of the course received high ratings from the students and overall course ratings were higher than in prior years when the course was given solely in lecture format. DICOM viewing software is an excellent tool for enabling students to learn radiologic anatomy from real-life clinical datasets. Interactive exercises performed in groups can be powerful tools for stimulating students to learn radiologic anatomy.

  4. An Aquatic Acoustic Metrics Interface Utility for Underwater Sound Monitoring and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Huiying; Halvorsen, Michele B.; Deng, Zhiqun

    Fishes and other marine mammals suffer a range of potential effects from intense sound sources generated by anthropogenic underwater processes such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording devices (USR) were built to monitor the acoustic sound pressure waves generated by those anthropogenic underwater activities, so the relevant processing software becomes indispensable for analyzing the audio files recorded by these USRs. However, existing software packages did not meet performance and flexibility requirements. In this paper, we provide a detailed description of a new software package, named Aquatic Acoustic Metrics Interface (AAMI), which is a Graphicalmore » User Interface (GUI) designed for underwater sound monitoring and analysis. In addition to the general functions, such as loading and editing audio files recorded by USRs, the software can compute a series of acoustic metrics in physical units, monitor the sound's influence on fish hearing according to audiograms from different species of fishes and marine mammals, and batch process the sound files. The detailed applications of the software AAMI will be discussed along with several test case scenarios to illustrate its functionality.« less

  5. NASA software documentation standard software engineering program

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The NASA Software Documentation Standard (hereinafter referred to as Standard) can be applied to the documentation of all NASA software. This Standard is limited to documentation format and content requirements. It does not mandate specific management, engineering, or assurance standards or techniques. This Standard defines the format and content of documentation for software acquisition, development, and sustaining engineering. Format requirements address where information shall be recorded and content requirements address what information shall be recorded. This Standard provides a framework to allow consistency of documentation across NASA and visibility into the completeness of project documentation. This basic framework consists of four major sections (or volumes). The Management Plan contains all planning and business aspects of a software project, including engineering and assurance planning. The Product Specification contains all technical engineering information, including software requirements and design. The Assurance and Test Procedures contains all technical assurance information, including Test, Quality Assurance (QA), and Verification and Validation (V&V). The Management, Engineering, and Assurance Reports is the library and/or listing of all project reports.

  6. VecScreen_plus_taxonomy: imposing a tax(onomy) increase on vector contamination screening.

    PubMed

    Schäffer, Alejandro A; Nawrocki, Eric P; Choi, Yoon; Kitts, Paul A; Karsch-Mizrachi, Ilene; McVeigh, Richard

    2018-03-01

    Nucleic acid sequences in public databases should not contain vector contamination, but many sequences in GenBank do (or did) contain vectors. The National Center for Biotechnology Information uses the program VecScreen to screen submitted sequences for contamination. Additional tools are needed to distinguish true-positive (contamination) from false-positive (not contamination) VecScreen matches. A principal reason for false-positive VecScreen matches is that the sequence and the matching vector subsequence originate from closely related or identical organisms (for example, both originate in Escherichia coli). We collected information on the taxonomy of sources of vector segments in the UniVec database used by VecScreen. We used that information in two overlapping software pipelines for retrospective analysis of contamination in GenBank and for prospective analysis of contamination in new sequence submissions. Using the retrospective pipeline, we identified and corrected over 8000 contaminated sequences in the nonredundant nucleotide database. The prospective analysis pipeline has been in production use since April 2017 to evaluate some new GenBank submissions. Data on the sources of UniVec entries were included in release 10.0 (ftp://ftp.ncbi.nih.gov/pub/UniVec/). The main software is freely available at https://github.com/aaschaffer/vecscreen_plus_taxonomy. aschaffe@helix.nih.gov. Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2017. This work is written by US Government employees and are in the public domain in the US.

  7. Software for Collaborative Use of Large Interactive Displays

    NASA Technical Reports Server (NTRS)

    Trimble, Jay; Shab, Thodore; Wales, Roxana; Vera, Alonso; Tollinger, Irene; McCurdy, Michael; Lyubimov, Dmitriy

    2006-01-01

    The MERBoard Collaborative Workspace, which is currently being deployed to support the Mars Exploration Rover (MER) Missions, is the first instantiation of a new computing architecture designed to support collaborative and group computing using computing devices situated in NASA mission operations room. It is a software system for generation of large-screen interactive displays by multiple users

  8. Physical Therapy Machine

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Loredan Biomedical, Inc.'s LIDO, a computerized physical therapy system, was purchased by NASA in 1985 for evaluation as a Space Station Freedom exercise program. In 1986, while involved in an ARC muscle conditioning project, Malcom Bond, Loredan's chairman, designed an advanced software package for NASA which became the basis for LIDOSOFT software used in the commercially available system. The system employs a "proprioceptive" software program which perceives internal body conditions, induces perturbations to muscular effort and evaluates the response. Biofeedback on a screen allows a patient to observe his own performance.

  9. Gray scale enhances display readability of bitmapped documents

    NASA Astrophysics Data System (ADS)

    Ostberg, Olov; Disfors, Dennis; Feng, Yingduo

    1994-05-01

    Bitmapped images of high resolution, say 300 dpi rastered documents, stored in the memory of a PC are at best only borderline readable on the PC's display screen (say a 72 dpi VGA monitor). Results from a series of exploratory psycho-physical experiments, using the Adobe PhotoshopR software, show that the readability can be significantly enhanced by making use of the monitor's capability to display shades of gray. It is suggested that such a gray scale adaptation module should be bundled to all software products for electronic document management. In fact, fax modems are already available in which this principle is employed, hereby making it possible to read incoming fax documents directly on the screen.

  10. Feasibility of utilizing a commercial eye tracker to assess electronic health record use during patient simulation.

    PubMed

    Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu

    2016-09-01

    Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.

  11. Impact of an electronic health record alert in primary care on increasing hepatitis c screening and curative treatment for baby boomers.

    PubMed

    Konerman, Monica A; Thomson, Mary; Gray, Kristen; Moore, Meghan; Choxi, Hetal; Seif, Elizabeth; Lok, Anna S F

    2017-12-01

    Despite effective treatment for chronic hepatitis C, deficiencies in diagnosis and access to care preclude disease elimination. Screening of baby boomers remains low. The aims of this study were to assess the impact of an electronic health record-based prompt on hepatitis C virus (HCV) screening rates in baby boomers in primary care and access to specialty care and treatment among those newly diagnosed. We implemented an electronic health record-based "best practice advisory" (BPA) that prompted primary care providers to perform HCV screening for patients seen in primary care clinic (1) born between 1945 and 1965, (2) who lacked a prior diagnosis of HCV infection, and (3) who lacked prior documented anti-HCV testing. The BPA had associated educational materials, order set, and streamlined access to specialty care for newly diagnosed patients. Pre-BPA and post-BPA screening rates were compared, and care of newly diagnosed patients was analyzed. In the 3 years prior to BPA implementation, 52,660 baby boomers were seen in primary care clinics and 28% were screened. HCV screening increased from 7.6% for patients with a primary care provider visit in the 6 months prior to BPA to 72% over the 1 year post-BPA. Of 53 newly diagnosed patients, all were referred for specialty care, 11 had advanced fibrosis or cirrhosis, 20 started treatment, and 9 achieved sustained virologic response thus far. Implementation of an electronic health record-based prompt increased HCV screening rates among baby boomers in primary care by 5-fold due to efficiency in determining needs for HCV screening and workflow design. Streamlined access to specialty care enabled patients with previously undiagnosed advanced disease to be cured. This intervention can be easily integrated into electronic health record systems to increase HCV diagnosis and linkage to care. (Hepatology 2017;66:1805-1813). © 2017 by the American Association for the Study of Liver Diseases.

  12. Large-scale virtual screening on public cloud resources with Apache Spark.

    PubMed

    Capuccini, Marco; Ahmed, Laeeq; Schaal, Wesley; Laure, Erwin; Spjuth, Ola

    2017-01-01

    Structure-based virtual screening is an in-silico method to screen a target receptor against a virtual molecular library. Applying docking-based screening to large molecular libraries can be computationally expensive, however it constitutes a trivially parallelizable task. Most of the available parallel implementations are based on message passing interface, relying on low failure rate hardware and fast network connection. Google's MapReduce revolutionized large-scale analysis, enabling the processing of massive datasets on commodity hardware and cloud resources, providing transparent scalability and fault tolerance at the software level. Open source implementations of MapReduce include Apache Hadoop and the more recent Apache Spark. We developed a method to run existing docking-based screening software on distributed cloud resources, utilizing the MapReduce approach. We benchmarked our method, which is implemented in Apache Spark, docking a publicly available target receptor against [Formula: see text]2.2 M compounds. The performance experiments show a good parallel efficiency (87%) when running in a public cloud environment. Our method enables parallel Structure-based virtual screening on public cloud resources or commodity computer clusters. The degree of scalability that we achieve allows for trying out our method on relatively small libraries first and then to scale to larger libraries. Our implementation is named Spark-VS and it is freely available as open source from GitHub (https://github.com/mcapuccini/spark-vs).Graphical abstract.

  13. Feasibility of simultaneous computed tomographic colonography and fully automated bone mineral densitometry in a single examination.

    PubMed

    Summers, Ronald M; Baecher, Nicolai; Yao, Jianhua; Liu, Jiamin; Pickhardt, Perry J; Choi, J Richard; Hill, Suvimol

    2011-01-01

    To show the feasibility of calculating the bone mineral density (BMD) from computed tomographic colonography (CTC) scans using fully automated software. Automated BMD measurement software was developed that measures the BMD of the first and second lumbar vertebrae on computed tomography and calculates the mean of the 2 values to provide a per patient BMD estimate. The software was validated in a reference population of 17 consecutive women who underwent quantitative computed tomography and in a population of 475 women from a consecutive series of asymptomatic patients enrolled in a CTC screening trial conducted at 3 medical centers. The mean (SD) BMD was 133.6 (34.6) mg/mL (95% confidence interval, 130.5-136.7; n = 475). In women aged 42 to 60 years (n = 316) and 61 to 79 years (n = 159), the mean (SD) BMDs were 143.1 (33.5) and 114.7 (28.3) mg/mL, respectively (P < 0.0001). Fully automated BMD measurements were reproducible for a given patient with 95% limits of agreement of -9.79 to 8.46 mg/mL for the mean difference between paired assessments on supine and prone CTC. Osteoporosis screening can be performed simultaneously with screening for colorectal polyps.

  14. Computer Decision Support to Improve Autism Screening and Care in Community Pediatric Clinics

    ERIC Educational Resources Information Center

    Bauer, Nerissa S.; Sturm, Lynne A.; Carroll, Aaron E.; Downs, Stephen M.

    2013-01-01

    An autism module was added to an existing computer decision support system (CDSS) to facilitate adherence to recommended guidelines for screening for autism spectrum disorders in primary care pediatric clinics. User satisfaction was assessed by survey and informal feedback at monthly meetings between clinical staff and the software team. To assess…

  15. MATLAB-based automated patch-clamp system for awake behaving mice

    PubMed Central

    Siegel, Jennifer J.; Taylor, William; Chitwood, Raymond A.; Johnston, Daniel

    2015-01-01

    Automation has been an important part of biomedical research for decades, and the use of automated and robotic systems is now standard for such tasks as DNA sequencing, microfluidics, and high-throughput screening. Recently, Kodandaramaiah and colleagues (Nat Methods 9: 585–587, 2012) demonstrated, using anesthetized animals, the feasibility of automating blind patch-clamp recordings in vivo. Blind patch is a good target for automation because it is a complex yet highly stereotyped process that revolves around analysis of a single signal (electrode impedance) and movement along a single axis. Here, we introduce an automated system for blind patch-clamp recordings from awake, head-fixed mice running on a wheel. In its design, we were guided by 3 requirements: easy-to-use and easy-to-modify software; seamless integration of behavioral equipment; and efficient use of time. The resulting system employs equipment that is standard for patch recording rigs, moderately priced, or simple to make. It is written entirely in MATLAB, a programming environment that has an enormous user base in the neuroscience community and many available resources for analysis and instrument control. Using this system, we obtained 19 whole cell patch recordings from neurons in the prefrontal cortex of awake mice, aged 8–9 wk. Successful recordings had series resistances that averaged 52 ± 4 MΩ and required 5.7 ± 0.6 attempts to obtain. These numbers are comparable with those of experienced electrophysiologists working manually, and this system, written in a simple and familiar language, will be useful to many cellular electrophysiologists who wish to study awake behaving mice. PMID:26084901

  16. A Speech Recognition-based Solution for the Automatic Detection of Mild Cognitive Impairment from Spontaneous Speech

    PubMed Central

    Tóth, László; Hoffmann, Ildikó; Gosztolya, Gábor; Vincze, Veronika; Szatlóczki, Gréta; Bánréti, Zoltán; Pákáski, Magdolna; Kálmán, János

    2018-01-01

    Background: Even today the reliable diagnosis of the prodromal stages of Alzheimer’s disease (AD) remains a great challenge. Our research focuses on the earliest detectable indicators of cognitive de-cline in mild cognitive impairment (MCI). Since the presence of language impairment has been reported even in the mild stage of AD, the aim of this study is to develop a sensitive neuropsychological screening method which is based on the analysis of spontaneous speech production during performing a memory task. In the future, this can form the basis of an Internet-based interactive screening software for the recognition of MCI. Methods: Participants were 38 healthy controls and 48 clinically diagnosed MCI patients. The provoked spontaneous speech by asking the patients to recall the content of 2 short black and white films (one direct, one delayed), and by answering one question. Acoustic parameters (hesitation ratio, speech tempo, length and number of silent and filled pauses, length of utterance) were extracted from the recorded speech sig-nals, first manually (using the Praat software), and then automatically, with an automatic speech recogni-tion (ASR) based tool. First, the extracted parameters were statistically analyzed. Then we applied machine learning algorithms to see whether the MCI and the control group can be discriminated automatically based on the acoustic features. Results: The statistical analysis showed significant differences for most of the acoustic parameters (speech tempo, articulation rate, silent pause, hesitation ratio, length of utterance, pause-per-utterance ratio). The most significant differences between the two groups were found in the speech tempo in the delayed recall task, and in the number of pauses for the question-answering task. The fully automated version of the analysis process – that is, using the ASR-based features in combination with machine learning - was able to separate the two classes with an F1-score of 78.8%. Conclusion: The temporal analysis of spontaneous speech can be exploited in implementing a new, auto-matic detection-based tool for screening MCI for the community. PMID:29165085

  17. A Speech Recognition-based Solution for the Automatic Detection of Mild Cognitive Impairment from Spontaneous Speech.

    PubMed

    Toth, Laszlo; Hoffmann, Ildiko; Gosztolya, Gabor; Vincze, Veronika; Szatloczki, Greta; Banreti, Zoltan; Pakaski, Magdolna; Kalman, Janos

    2018-01-01

    Even today the reliable diagnosis of the prodromal stages of Alzheimer's disease (AD) remains a great challenge. Our research focuses on the earliest detectable indicators of cognitive decline in mild cognitive impairment (MCI). Since the presence of language impairment has been reported even in the mild stage of AD, the aim of this study is to develop a sensitive neuropsychological screening method which is based on the analysis of spontaneous speech production during performing a memory task. In the future, this can form the basis of an Internet-based interactive screening software for the recognition of MCI. Participants were 38 healthy controls and 48 clinically diagnosed MCI patients. The provoked spontaneous speech by asking the patients to recall the content of 2 short black and white films (one direct, one delayed), and by answering one question. Acoustic parameters (hesitation ratio, speech tempo, length and number of silent and filled pauses, length of utterance) were extracted from the recorded speech signals, first manually (using the Praat software), and then automatically, with an automatic speech recognition (ASR) based tool. First, the extracted parameters were statistically analyzed. Then we applied machine learning algorithms to see whether the MCI and the control group can be discriminated automatically based on the acoustic features. The statistical analysis showed significant differences for most of the acoustic parameters (speech tempo, articulation rate, silent pause, hesitation ratio, length of utterance, pause-per-utterance ratio). The most significant differences between the two groups were found in the speech tempo in the delayed recall task, and in the number of pauses for the question-answering task. The fully automated version of the analysis process - that is, using the ASR-based features in combination with machine learning - was able to separate the two classes with an F1-score of 78.8%. The temporal analysis of spontaneous speech can be exploited in implementing a new, automatic detection-based tool for screening MCI for the community. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Family Members of Patients with Abdominal Aortic Aneurysms are at Increased Risk for Aneurysms: Analysis of 618 Probands and their Families from the Liège AAA Family Study

    PubMed Central

    Sakalihasan, Natzi; Defraigne, Jean-Olivier; Kerstenne, Marie-Ange; Cheramy-Bien, Jean-Paul; Smelser, Diane T.; Tromp, Gerard; Kuivaniemi, Helena

    2014-01-01

    Background The objectives were to answer the following questions using a well-characterized population in Liège, Belgium: 1) what percentage of abdominal aortic aneurysm (AAA) patients have a positive family history for AAA, 2) what is the prevalence of AAAs among relatives of AAA patients; and 3) do familial and sporadic AAA cases differ in clinical characteristics. Methods and Results Unrelated AAA patients diagnosed at the Cardiovascular Surgery Department, University Hospital of Liège, Belgium, between 1999 and 2012 were invited to the study. A detailed family history was obtained in interviews and recorded using Progeny software. In the initial interview 62 (10%) of the 618 AAA patients reported a positive family history for AAA. We divided the 618 patients into two study groups: Group I: 296 AAA patients (268; 91% males) were followed up with computerized tomography combined with positron emission tomography, and Group II: 322 AAA patients (295; 92% males) whose families were invited to ultrasonography screening. Ultrasonography screening identified 24 new AAAs among 186 relatives (≥ 50 years) of 144 families yielding a prevalence of 13%. The highest prevalence (25%) was found among brothers. By combining the number of AAAs found by ultrasonography screening with those diagnosed previously the observed lifetime prevalence of AAA was estimated to be 32% in brothers. The familial AAA cases were more likely to have a ruptured AAA than the sporadic cases (8% vs. 2.4%; P<0.0001). Conclusions The findings confirm previously found high prevalence of AAA among brothers, support genetic contribution to AAA pathogenesis and provide rationale for targeted screening of relatives of AAA patients. PMID:24365082

  19. Family members of patients with abdominal aortic aneurysms are at increased risk for aneurysms: analysis of 618 probands and their families from the Liège AAA Family Study.

    PubMed

    Sakalihasan, Natzi; Defraigne, Jean-Olivier; Kerstenne, Marie-Ange; Cheramy-Bien, Jean-Paul; Smelser, Diane T; Tromp, Gerard; Kuivaniemi, Helena

    2014-05-01

    The objectives were to answer the following questions with the help of a well-characterized population in Liège, Belgium: 1) what percentage of patients with abdominal aortic aneurysm (AAA) have a positive family history for AAA? 2) what is the prevalence of AAAs among relatives of patients with AAA? and 3) do familial and sporadic AAA cases differ in clinical characteristics? Patients with unrelated AAA diagnosed at the Cardiovascular Surgery Department, University Hospital of Liège, Belgium, between 1999 and 2012 were invited to the study. A detailed family history was obtained in interviews and recorded using Progeny software. We divided the 618 patients into 2 study groups: group I, 296 patients with AAA (268; 91% men) were followed up with computerized tomography combined with positron emission tomography; and group II, 322 patients with AAA (295; 92% men) whose families were invited to ultrasonographic screening. In the initial interview, 62 (10%) of the 618 patients with AAA reported a positive family history for AAA. Ultrasonographic screening identified 24 new AAAs among 186 relatives (≥50 years) of 144 families yielding a prevalence of 13%. The highest prevalence (25%) was found among brothers. By combining the number of AAAs found by ultrasonographic screening with those diagnosed previously the observed lifetime prevalence of AAA was estimated to be 32% in brothers. The familial AAA cases were more likely to have a ruptured AAA than the sporadic cases (8% vs. 2.4%; P < 0.0001). The findings confirm previously found high prevalence of AAA among brothers, support genetic contribution to AAA pathogenesis, and provide rationale for targeted screening of relatives of patients with AAA. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. [Computerized monitoring for integrated cervical screening. Rationale, methods and indicators of participation].

    PubMed

    Bucchi, L; Pierri, C; Caprara, L; Cortecchia, S; De Lillo, M; Bondi, A

    2003-02-01

    This paper presents a computerised system for the monitoring of integrated cervical screening, i.e. the integration of spontaneous Pap smear practice into organised screening. The general characteristics of the system are described, including background and rationale (integrated cervical screening in European countries, impact of integration on monitoring, decentralised organization of screening and levels of monitoring), general methods (definitions, sections, software description, and setting of application), and indicators of participation (distribution by time interval since previous Pap smear, distribution by screening sector--organised screening centres vs public and private clinical settings--, distribution by time interval between the last two Pap smears, and movement of women between the two screening sectors). Also, the paper reports the results of the application of these indicators in the general database of the Pathology Department of Imola Health District in northern Italy.

  1. Changing case Order to Optimise patterns of Performance in mammography Screening (CO-OPS): study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background X-ray mammography remains the predominant test for screening for breast cancer, with the aim of reducing breast cancer mortality. In the English NHS Breast Screening Programme each woman’s mammograms are examined separately by two expert readers. The two readers read each batch in the same order and each indicates if there should be recall for further tests. This is a highly skilled, pressurised, repetitive and frequently intellectually unchallenging activity where readers examine one or more batches of 30–50 women’s mammograms in each session. A vigilance decrement or performance decrease over time has been observed in similar repetitive visual tasks such as radar operation. Methods/Design The CO-OPS study is a pragmatic, multi-centre, two-arm, double blind cluster randomised controlled trial of a computer software intervention designed to reduce the effects of a vigilance decrement in breast cancer screening. The unit of randomisation is the batch. Intervention batches will be examined in the opposite order by the two readers (one forwards, one backwards). Control batches will be read in the same order as one another, as is current standard practice. The hypothesis is that cancer detection rates will be higher in the intervention group because each readers’ peak performance will occur when examining different women’s mammograms. The trial will take place in 44 English breast screening centres for 1 year and 4 months. The primary outcome is cancer detection rate, which will be extracted from computer records after 1 year of the trial. The secondary outcomes include rate of disagreement between readers (a more statistically powerful surrogate for cancer detection rate), recall rate, positive predictive value, and interval cancer rate (cancers found between screening rounds which will be measured three years after the end of the trial). Discussion This is the first trial of an intervention to ameliorate a vigilance decrement in breast cancer screening. Trial registration ISRCTN46603370 (submitted: 24 October 2012, date of registration: 26 March 2013). PMID:24411004

  2. Food Intake Recording Software System, version 4 (FIRSSt4): A self-completed 24-h dietary recall for children

    USDA-ARS?s Scientific Manuscript database

    The Food Intake Recording Software System, version 4 (FIRSSt4), is a web-based 24-h dietary recall (24 hdr) self-administered by children based on the Automated Self-Administered 24-h recall (ASA24) (a self-administered 24 hdr for adults). The food choices in FIRSSt4 are abbreviated to include only ...

  3. Doing Our Homework: A Pre-Employment Screening Checklist for Better Head Start Hiring.

    ERIC Educational Resources Information Center

    McSherry, Jim; Caruso, Karen; Cagnetta, Mary

    1999-01-01

    Provides a checklist for screening potential Head Start employees. Components include checks for criminal record, credit history, motor vehicle records, social security number tracing, previous address research, education verification, work and personal reference interview, and professional license verification. (KB)

  4. The making of the mechanical universe

    NASA Technical Reports Server (NTRS)

    Blinn, James

    1989-01-01

    The Mechanical Universe project required the production of over 550 different animated scenes, totaling about 7 and 1/2 hours of screen time. The project required the use of a wide range of techniques and motivated the development of several different software packages. A documentation is presented of many aspects of the project, encompassing artistic design issues, scientific simulations, software engineering, and video engineering.

  5. User's manual for the VAX-Gerber link software package. Revision 1. 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isobe, G.W.

    1985-10-01

    This manual provides a user the information necessary to run the VAX-Gerber link software package. It is expected that the user already knows how to login to the VAX, and is familiar with the Gerber Photo Plotter. It is also highly desirable that the user be familiar with the full screen editor on the VAX, EDT.

  6. Network of fully integrated multispecialty hospital imaging systems

    NASA Astrophysics Data System (ADS)

    Dayhoff, Ruth E.; Kuzmak, Peter M.

    1994-05-01

    The Department of Veterans Affairs (VA) DHCP Imaging System records clinically significant diagnostic images selected by medical specialists in a variety of departments, including radiology, cardiology, gastroenterology, pathology, dermatology, hematology, surgery, podiatry, dental clinic, and emergency room. These images are displayed on workstations located throughout a medical center. All images are managed by the VA's hospital information system, allowing integrated displays of text and image data across medical specialties. Clinicians can view screens of `thumbnail' images for all studies or procedures performed on a selected patient. Two VA medical centers currently have DHCP Imaging Systems installed, and others are planned. All VA medical centers and other VA facilities are connected by a wide area packet-switched network. The VA's electronic mail software has been modified to allow inclusion of binary data such as images in addition to the traditional text data. Testing of this multimedia electronic mail system is underway for medical teleconsultation.

  7. LabPatch, an acquisition and analysis program for patch-clamp electrophysiology.

    PubMed

    Robinson, T; Thomsen, L; Huizinga, J D

    2000-05-01

    An acquisition and analysis program, "LabPatch," has been developed for use in patch-clamp research. LabPatch controls any patch-clamp amplifier, acquires and records data, runs voltage protocols, plots and analyzes data, and connects to spreadsheet and database programs. Controls within LabPatch are grouped by function on one screen, much like an oscilloscope front panel. The software is mouse driven, so that the user need only point and click. Finally, the ability to copy data to other programs running in Windows 95/98, and the ability to keep track of experiments using a database, make LabPatch extremely versatile. The system requirements include Windows 95/98, at least a 100-MHz processor and 16 MB RAM, a data acquisition card, digital-to-analog converter, and a patch-clamp amplifier. LabPatch is available free of charge at http://www.fhs.mcmaster.ca/huizinga/.

  8. Computer capillaroscopy as a new cardiological diagnostics method

    NASA Astrophysics Data System (ADS)

    Gurfinkel, Youri I.; Korol, Oleg A.; Kufal, George E.

    1998-04-01

    The blood flow in capillary vessels plays an important role in sustaining the vital activity of the human organism. The computerized capillaroscope is used for the investigations of nailfold (eponychium) capillary blood flow. An important advantage of the instrument is the possibility of performing non-invasive investigations, i.e., without damage to skin or vessels and causing no pain or unpleasant sensations. The high-class equipment and software allow direct observation of capillary blood flow dynamics on a computer screen at a 700 - 1300 times magnification. For the first time in the clinical practice, it has become possible to precisely measure the speed of capillary blood flow, as well as the frequency of aggregate formation (glued together in clots of blood particles). In addition, provision is made for automatic measurement of capillary size and wall thickness and automatic recording of blood aggregate images for further visual study, documentation, and electronic database management.

  9. TOPEX Software Document Series. Volume 5; Rev. 1; TOPEX GDR Processing

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey; Lockwood, Dennis; Hancock, David W., III

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Geophysical Data Record (GDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  10. 47 CFR 32.2690 - Intangibles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS... purpose computer software and for network software. Subsidiary records for this account shall also include..., not including software, having a life of one year or less shall be charged directly to Account 6564...

  11. Recording and assessment of evoked potentials with electrode arrays.

    PubMed

    Miljković, N; Malešević, N; Kojić, V; Bijelić, G; Keller, T; Popović, D B

    2015-09-01

    In order to optimize procedure for the assessment of evoked potentials and to provide visualization of the flow of action potentials along the motor systems, we introduced array electrodes for stimulation and recording and developed software for the analysis of the recordings. The system uses a stimulator connected to an electrode array for the generation of evoked potentials, an electrode array connected to the amplifier, A/D converter and computer for the recording of evoked potentials, and a dedicated software application. The method has been tested for the assessment of the H-reflex on the triceps surae muscle in six healthy humans. The electrode array with 16 pads was positioned over the posterior aspect of the thigh, while the recording electrode array with 16 pads was positioned over the triceps surae muscle. The stimulator activated all the pads of the stimulation electrode array asynchronously, while the signals were recorded continuously at all the recording sites. The results are topography maps (spatial distribution of evoked potentials) and matrices (spatial visualization of nerve excitability). The software allows the automatic selection of the lowest stimulation intensity to achieve maximal H-reflex amplitude and selection of the recording/stimulation pads according to predefined criteria. The analysis of results shows that the method provides rich information compared with the conventional recording of the H-reflex with regard the spatial distribution.

  12. Fluidica CFD software for fluids instruction

    NASA Astrophysics Data System (ADS)

    Colonius, Tim

    2008-11-01

    Fluidica is an open-source freely available Matlab graphical user interface (GUI) to to an immersed-boundary Navier- Stokes solver. The algorithm is programmed in Fortran and compiled into Matlab as mex-function. The user can create external flows about arbitrarily complex bodies and collections of free vortices. The code runs fast enough for complex 2D flows to be computed and visualized in real-time on the screen. This facilitates its use in homework and in the classroom for demonstrations of various potential-flow and viscous flow phenomena. The GUI has been written with the goal of allowing the student to learn how to use the software as she goes along. The user can select which quantities are viewed on the screen, including contours of various scalars, velocity vectors, streamlines, particle trajectories, streaklines, and finite-time Lyapunov exponents. In this talk, we demonstrate the software in the context of worked classroom examples demonstrating lift and drag, starting vortices, separation, and vortex dynamics.

  13. Nuclear Test Depth Determination with Synthetic Modelling: Global Analysis from PNEs to DPRK-2016

    NASA Astrophysics Data System (ADS)

    Rozhkov, Mikhail; Stachnik, Joshua; Baker, Ben; Epiphansky, Alexey; Bobrov, Dmitry

    2016-04-01

    Seismic event depth determination is critical for the event screening process at the International Data Center, CTBTO. A thorough determination of the event depth can be conducted mostly through additional special analysis because the IDC's Event Definition Criteria is based, in particular, on depth estimation uncertainties. This causes a large number of events in the Reviewed Event Bulletin to have depth constrained to the surface making the depth screening criterion not applicable. Further it may result in a heavier workload to manually distinguish between subsurface and deeper crustal events. Since the shape of the first few seconds of signal of very shallow events is very sensitive to the depth phases, cross correlation between observed and theoretic seismograms can provide a basis for the event depth estimation, and so an expansion to the screening process. We applied this approach mostly to events at teleseismic and partially regional distances. The approach was found efficient for the seismic event screening process, with certain caveats related mostly to poorly defined source and receiver crustal models which can shift the depth estimate. An adjustable teleseismic attenuation model (t*) for synthetics was used since this characteristic is not known for most of the rays we studied. We studied a wide set of historical records of nuclear explosions, including so called Peaceful Nuclear Explosions (PNE) with presumably known depths, and recent DPRK nuclear tests. The teleseismic synthetic approach is based on the stationary phase approximation with hudson96 program, and the regional modelling was done with the generalized ray technique by Vlastislav Cerveny modified to account for the complex source topography. The software prototype is designed to be used for the Expert Technical Analysis at the IDC. With this, the design effectively reuses the NDC-in-a-Box code and can be comfortably utilized by the NDC users. The package uses Geotool as a front-end for data retrieval and pre-processing. After the event database is compiled, the control is passed to the driver software, running the external processing and plotting toolboxes, which controls the final stage and produces the final result. The modules are mostly Python coded, C-coded (Raysynth3D complex topography regional synthetics) and FORTRAN coded synthetics from the CPS330 software package by Robert Herrmann of Saint Louis University. The extension of this single station depth determination method is under development and uses joint information from all stations participating in processing. It is based on simultaneous depth and moment tensor determination for both short and long period seismic phases. A novel approach recently developed for microseismic event location utilizing only phase waveform information was migrated to a global scale. It should provide faster computation as it does not require intensive synthetic modelling, and might benefit processing noisy signals. A consistent depth estimate for all recent nuclear tests was produced for the vast number of IMS stations (primary and auxiliary) used in processing.

  14. Analysis on composition rules of Chinese patent drugs treating pain-related diseases based on data mining method.

    PubMed

    Tang, Shi-Huan; Shen, Dan; Yang, Hong-Jun

    2017-08-24

    To analyze the composition rules of oral prescriptions in the treatment of headache, stomachache and dysmenorrhea recorded in National Standard for Chinese Patent Drugs (NSCPD) enacted by Ministry of Public Health of China and then make comparison between them to better understand pain treatment in different regions of human body. Constructed NSCPD database had been constructed in 2014. Prescriptions treating the three pain-related diseases were searched and screened from the database. Then data mining method such as association rules analysis and complex system entropy method integrated in the data mining software Traditional Chinese Medicine Inheritance Support System (TCMISS) were applied to process the data. Top 25 drugs with high frequency in the treatment of each disease were selected, and 51, 33 and 22 core combinations treating headache, stomachache and dysmenorrhea respectively were mined out as well. The composition rules of the oral prescriptions for treating headache, stomachache and dysmenorrhea recorded in NSCPD has been summarized. Although there were similarities between them, formula varied according to different locations of pain. It can serve as an evidence and reference for clinical treatment and new drug development.

  15. Eye Carduino: A Car Control System using Eye Movements

    NASA Astrophysics Data System (ADS)

    Kumar, Arjun; Nagaraj, Disha; Louzardo, Joel; Hegde, Rajeshwari

    2011-12-01

    Modern automotive systems are rapidly becoming highly of transportation, but can be a web integrated media centre. This paper explains the implementation of a vehicle control defined and characterized by embedded electronics and software. With new technologies, the vehicle industry is facing new opportunities and also new challenges. Electronics have improved the performance of vehicles and at the same time, new more complex applications are introduced. Examples of high level applications include adaptive cruise control and electronic stability programs (ESP). Further, a modern vehicle does not have to be merely a means using only eye movements. The EyeWriter's native hardware and software work to return the co-ordinates of where the user is looking. These co-ordinates are then used to control the car. A centre-point is defined on the screen. The higher on the screen the user's gaze is, the faster the car will accelerate. Braking is done by looking below centre. Steering is done by looking left and right on the screen.

  16. Development of x-ray imaging technique for liquid screening at airport

    NASA Astrophysics Data System (ADS)

    Sulaiman, Nurhani binti; Srisatit, Somyot

    2016-01-01

    X-ray imaging technology is a viable option to recognize flammable liquids for the purposes of aviation security. In this study, an X-ray imaging technology was developed whereby, the image viewing system was built with the use of a digital camera coupled with a gadolinium oxysulfide (GOS) fluorescent screen. The camera was equipped with a software for remote control setting of the camera via a USB cable which allows the images to be captured. The image was analysed to determine the average grey level using a software designed by Microsoft Visual Basic 6.0. The data was obtained for various densities of liquid thickness of 4.5 cm, 6.0 cm and 7.5 cm respectively for X-ray energies ranging from 70 to 200 kVp. In order to verify the reliability of the constructed calibration data, the system was tested with a few types of unknown liquids. The developed system could be conveniently employed for security screening in order to discriminate between a threat and an innocuous liquid.

  17. Automated phenotype pattern recognition of zebrafish for high-throughput screening.

    PubMed

    Schutera, Mark; Dickmeis, Thomas; Mione, Marina; Peravali, Ravindra; Marcato, Daniel; Reischl, Markus; Mikut, Ralf; Pylatiuk, Christian

    2016-07-03

    Over the last years, the zebrafish (Danio rerio) has become a key model organism in genetic and chemical screenings. A growing number of experiments and an expanding interest in zebrafish research makes it increasingly essential to automatize the distribution of embryos and larvae into standard microtiter plates or other sample holders for screening, often according to phenotypical features. Until now, such sorting processes have been carried out by manually handling the larvae and manual feature detection. Here, a prototype platform for image acquisition together with a classification software is presented. Zebrafish embryos and larvae and their features such as pigmentation are detected automatically from the image. Zebrafish of 4 different phenotypes can be classified through pattern recognition at 72 h post fertilization (hpf), allowing the software to classify an embryo into 2 distinct phenotypic classes: wild-type versus variant. The zebrafish phenotypes are classified with an accuracy of 79-99% without any user interaction. A description of the prototype platform and of the algorithms for image processing and pattern recognition is presented.

  18. 48 CFR 352.227-14 - Rights in Data-Exceptional Circumstances.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....] Computer database or database means a collection of recorded information in a form capable of, and for the... databases or computer software documentation. Computer software documentation means owner's manuals, user's... nature (including computer databases and computer software documentation). This term does not include...

  19. Development of a web-based tool for automated processing and cataloging of a unique combinatorial drug screen.

    PubMed

    Dalecki, Alex G; Wolschendorf, Frank

    2016-07-01

    Facing totally resistant bacteria, traditional drug discovery efforts have proven to be of limited use in replenishing our depleted arsenal of therapeutic antibiotics. Recently, the natural anti-bacterial properties of metal ions in synergy with metal-coordinating ligands have shown potential for generating new molecule candidates with potential therapeutic downstream applications. We recently developed a novel combinatorial screening approach to identify compounds with copper-dependent anti-bacterial properties. Through a parallel screening technique, the assay distinguishes between copper-dependent and independent activities against Mycobacterium tuberculosis with hits being defined as compounds with copper-dependent activities. These activities must then be linked to a compound master list to process and analyze the data and to identify the hit molecules, a labor intensive and mistake-prone analysis. Here, we describe a software program built to automate this analysis in order to streamline our workflow significantly. We conducted a small, 1440 compound screen against M. tuberculosis and used it as an example framework to build and optimize the software. Though specifically adapted to our own needs, it can be readily expanded for any small- to medium-throughput screening effort, parallel or conventional. Further, by virtue of the underlying Linux server, it can be easily adapted for chemoinformatic analysis of screens through packages such as OpenBabel. Overall, this setup represents an easy-to-use solution for streamlining processing and analysis of biological screening data, as well as offering a scaffold for ready functionality expansion. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. How to identify students for school-based depression intervention: can school record review be substituted for universal depression screening?

    PubMed

    Kuo, Elena S; Vander Stoep, Ann; Herting, Jerald R; Grupp, Katherine; McCauley, Elizabeth

    2013-02-01

    Early identification and intervention are critical for reducing the adverse effects of depression on academic and occupational performance. Cost-effective approaches are needed for identifying adolescents at high depression risk. This study evaluated the utility of school record review versus universal school-based depression screening for determining eligibility for an indicated depression intervention program implemented in the middle school setting. Algorithms derived from grades, attendance, suspensions, and basic demographic information were evaluated with regard to their ability to predict students' depression screening scores. The school information-based algorithms proved poor proxies for individual students' depression screening results. However, school records showed promise for identifying low, medium, and high-yield subgroups on the basis of which efficient screening targeting decisions could be made. Study results will help to guide school nurses who coordinate indicated depression intervention programs in school settings as they evaluate options of approaches for determining which students are eligible for participation. © 2012 Wiley Periodicals, Inc.

  1. Portable open-path optical remote sensing (ORS) Fourier transform infrared (FTIR) instrumentation miniaturization and software for point and click real-time analysis

    NASA Astrophysics Data System (ADS)

    Zemek, Peter G.; Plowman, Steven V.

    2010-04-01

    Advances in hardware have miniaturized the emissions spectrometer and associated optics, rendering them easily deployed in the field. Such systems are also suitable for vehicle mounting, and can provide high quality data and concentration information in minutes. Advances in software have accompanied this hardware evolution, enabling the development of portable point-and-click OP-FTIR systems that weigh less than 16 lbs. These systems are ideal for first-responders, military, law enforcement, forensics, and screening applications using optical remote sensing (ORS) methodologies. With canned methods and interchangeable detectors, the new generation of OP-FTIR technology is coupled to the latest forward reference-type model software to provide point-and-click technology. These software models have been established for some time. However, refined user-friendly models that use active, passive, and solar occultation methodologies now allow the user to quickly field-screen and quantify plumes, fence-lines, and combustion incident scenarios in high-temporal-resolution. Synthetic background generation is now redundant as the models use highly accurate instrument line shape (ILS) convolutions and several other parameters, in conjunction with radiative transfer model databases to model a single calibration spectrum to collected sample spectra. Data retrievals are performed directly on single beam spectra using non-linear classical least squares (NLCLS). Typically, the Hitran line database is used to generate the initial calibration spectrum contained within the software.

  2. Development of a Software Safety Process and a Case Study of Its Use

    NASA Technical Reports Server (NTRS)

    Knight, J. C.

    1996-01-01

    Research in the year covered by this reporting period has been primarily directed toward: continued development of mock-ups of computer screens for operator of a digital reactor control system; development of a reactor simulation to permit testing of various elements of the control system; formal specification of user interfaces; fault-tree analysis including software; evaluation of formal verification techniques; and continued development of a software documentation system. Technical results relating to this grant and the remainder of the principal investigator's research program are contained in various reports and papers.

  3. Software design for analysis of multichannel intracardial and body surface electrocardiograms.

    PubMed

    Potse, Mark; Linnenbank, André C; Grimbergen, Cornelis A

    2002-11-01

    Analysis of multichannel ECG recordings (body surface maps (BSMs) and intracardial maps) requires special software. We created a software package and a user interface on top of a commercial data analysis package (MATLAB) by a combination of high-level and low-level programming. Our software was created to satisfy the needs of a diverse group of researchers. It can handle a large variety of recording configurations. It allows for interactive usage through a fast and robust user interface, and batch processing for the analysis of large amounts of data. The package is user-extensible, includes routines for both common and experimental data processing tasks, and works on several computer platforms. The source code is made intelligible using software for structured documentation and is available to the users. The package is currently used by more than ten research groups analysing ECG data worldwide.

  4. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching.

    PubMed

    Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W

    2010-04-01

    The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

  5. SpotMetrics: An Open-Source Image-Analysis Software Plugin for Automatic Chromatophore Detection and Measurement

    PubMed Central

    Hadjisolomou, Stavros P.; El-Haddad, George

    2017-01-01

    Coleoid cephalopods (squid, octopus, and sepia) are renowned for their elaborate body patterning capabilities, which are employed for camouflage or communication. The specific chromatic appearance of a cephalopod, at any given moment, is a direct result of the combined action of their intradermal pigmented chromatophore organs and reflecting cells. Therefore, a lot can be learned about the cephalopod coloration system by video recording and analyzing the activation of individual chromatophores in time. The fact that adult cephalopods have small chromatophores, up to several hundred thousand in number, makes measurement and analysis over several seconds a difficult task. However, current advancements in videography enable high-resolution and high framerate recording, which can be used to record chromatophore activity in more detail and accuracy in both space and time domains. In turn, the additional pixel information and extra frames per video from such recordings result in large video files of several gigabytes, even when the recording spans only few minutes. We created a software plugin, “SpotMetrics,” that can automatically analyze high resolution, high framerate video of chromatophore organ activation in time. This image analysis software can track hundreds of individual chromatophores over several hundred frames to provide measurements of size and color. This software may also be used to measure differences in chromatophore activation during different behaviors which will contribute to our understanding of the cephalopod sensorimotor integration system. In addition, this software can potentially be utilized to detect numbers of round objects and size changes in time, such as eye pupil size or number of bacteria in a sample. Thus, we are making this software plugin freely available as open-source because we believe it will be of benefit to other colleagues both in the cephalopod biology field and also within other disciplines. PMID:28298896

  6. WFF TOPEX Software Documentation Altimeter Instrument File (AIF) Processing, October 1998. Volume 3

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey; Lockwood, Dennis

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  7. Operative record using intraoperative digital data in neurosurgery.

    PubMed

    Houkin, K; Kuroda, S; Abe, H

    2000-01-01

    The purpose of this study was to develop a new method for more efficient and accurate operative records using intra-operative digital data in neurosurgery, including macroscopic procedures and microscopic procedures under an operating microscope. Macroscopic procedures were recorded using a digital camera and microscopic procedures were also recorded using a microdigital camera attached to an operating microscope. Operative records were then recorded digitally and filed in a computer using image retouch software and database base software. The time necessary for editing of the digital data and completing the record was less than 30 minutes. Once these operative records are digitally filed, they are easily transferred and used as database. Using digital operative records along with digital photography, neurosurgeons can document their procedures more accurately and efficiently than by the conventional method (handwriting). A complete digital operative record is not only accurate but also time saving. Construction of a database, data transfer and desktop publishing can be achieved using the intra-operative data, including intra-operative photographs.

  8. 10 CFR 602.19 - Records and data.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... software used to compile, manage, and analyze data; (2) Define all technical characteristics necessary for reading or processing the records; (3) Define file and record content and codes; (4) Describe update...

  9. 10 CFR 602.19 - Records and data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... software used to compile, manage, and analyze data; (2) Define all technical characteristics necessary for reading or processing the records; (3) Define file and record content and codes; (4) Describe update...

  10. 10 CFR 602.19 - Records and data.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... software used to compile, manage, and analyze data; (2) Define all technical characteristics necessary for reading or processing the records; (3) Define file and record content and codes; (4) Describe update...

  11. 10 CFR 602.19 - Records and data.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... software used to compile, manage, and analyze data; (2) Define all technical characteristics necessary for reading or processing the records; (3) Define file and record content and codes; (4) Describe update...

  12. 10 CFR 602.19 - Records and data.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... software used to compile, manage, and analyze data; (2) Define all technical characteristics necessary for reading or processing the records; (3) Define file and record content and codes; (4) Describe update...

  13. Reverse screening methods to search for the protein targets of chemopreventive compounds

    NASA Astrophysics Data System (ADS)

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-05-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.

  14. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds.

    PubMed

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.

  15. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds

    PubMed Central

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction. PMID:29868550

  16. Enhancing DSN Operations Efficiency with the Discrepancy Reporting Management System (DRMS)

    NASA Technical Reports Server (NTRS)

    Chatillon, Mark; Lin, James; Cooper, Tonja M.

    2003-01-01

    The DRMS is the Discrepancy Reporting Management System used by the Deep Space Network (DSN). It uses a web interface and is a management tool designed to track and manage: data outage incidents during spacecraft tracks against equipment and software known as DRs (discrepancy Reports), to record "out of pass" incident logs against equipment and software in a Station Log, to record instances where equipment has be restarted or reset as Reset records, and to electronically record equipment readiness status across the DSN. Tracking and managing these items increases DSN operational efficiency by providing: the ability to establish the operational history of equipment items, data on the quality of service provided to the DSN customers, the ability to measure service performance, early insight into processes, procedures and interfaces that may need updating or changing, and the capability to trace a data outage to a software or hardware change. The items listed above help the DSN to focus resources on areas of most need.

  17. Development and Implementation of the DHAPP Military eHealth Information Network System.

    PubMed

    Kratz, Mary; Thomas, Anne; Hora, Ricardo; Vera, Delphis; Lutz, Mickey; Johnson, Mark D

    2017-01-01

    As the Joint United Nations Programme on HIV/AIDS, the Global Fund, and the US President's Emergency Plan for AIDS Relief focus on reaching 90-90-90 goals, military health systems are scaling up to meet the data demands of these ambitious objectives. Since 2008, the US Department of Defense HIV/AIDS Prevention Program (DHAPP) has been working with military partners in 14 countries on implementation and adoption of a Military eHealth Information Network (MeHIN). Each country implementation plan followed a structured process using international eHealth standards. DHAPP worked with the private sector to develop a commercial-off-the-shelf (COTS) electronic medical record (EMR) for the collection of data, including patient demographic information, clinical notes for general medical care, HIV encounters, voluntary medical male circumcision, and tuberculosis screening information. The COTS software approach provided a zero-dollar software license and focused on sharing a single version of the EMR across countries, so that all countries could benefit from software enhancements and new features over time. DHAPP also worked with the public sector to modify open source disease surveillance tools and open access of HIV training materials. Important lessons highlight challenges to eHealth implementation, including a paucity of technology infrastructure, military leadership rotations, and the need for basic computer skills building. While not simple, eHealth systems can be built and maintained with requisite security, flexibility, and reporting capabilities that provide critical information to improve the health of individuals and organizations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Analysis of clinical decision support system malfunctions: a case series and survey

    PubMed Central

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-01-01

    Objective To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. Materials and Methods We identified and investigated several CDSS malfunctions at Brigham and Women’s Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. Results We identified four CDSS malfunctions at Brigham and Women’s Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. Discussion CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. Conclusion CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. PMID:27026616

  19. Coverage of the Victorian newborn screening programme in 2003: a retrospective population study.

    PubMed

    Jaques, Alice M; Collins, Veronica R; Pitt, James; Halliday, Jane L

    2008-09-01

    To assess the coverage of the newborn screening (NBS) program in Victoria, Australia, and identify potential predictors of not being screened. Victoria, Australia, 2003. The Victorian NBS program screens for phenylketonuria (PKU), cystic fibrosis, congenital hypothyroidism and more than 20 metabolic conditions, such as medium chain acyl-coenzyme A dehydrogenase (MCAD) deficiency. Victorian birth records (n = 63,018) were linked to Victorian NBS records (n = 62,876) using probabilistic record linkage. Binary logistic regression was used to identify potential predictors of not being screened. Uptake of NBS was 99.4% (62,643/63,018), resulting in 0.6% (375) of livebirths not matched to a NBS test. Neonatal death was the most significant factor associated with not being screened (relative risk (RR) = 407, 95%Cl = 314 to 526). After adjustment, surviving livebirths had an increased likelihood of not being matched to a NBS record if they: were transferred between hospitals (odds ratio (OR) = 2.4, 95% confidence interval (Cl) 1.5 to 3.9); were born at home (OR = 12.1, 95%Cl 6.3 to 23.3); resided in rural Victoria (OR = 2.6, 95%Cl 1.5 to 4.3); stayed in hospital for one day or less (OR = 4.6, 95%Cl 2.8 to 7.6); or whose mothers were primiparous (OR = 1.5, 95%Cl 1.1 to 2.1). NBS uptake is extremely high in Victoria with over 99% of livebirths screened. Particular risk factors for not having NBS have now been identified, which could lead to changes around monitoring neonates who are not born in a hospital, or leave/transfer hospital, before the NBS period (48-72 hours). Future studies could determine whether those not screened had opted-out or were not offered NBS.

  20. A cost-effectiveness analysis of screening for silent atrial fibrillation after ischaemic stroke.

    PubMed

    Levin, Lars-Åke; Husberg, Magnus; Sobocinski, Piotr Doliwa; Kull, Viveka Frykman; Friberg, Leif; Rosenqvist, Mårten; Davidson, Thomas

    2015-02-01

    The purpose of this study was to estimate the cost-effectiveness of two screening methods for detection of silent AF, intermittent electrocardiogram (ECG) recordings using a handheld recording device, at regular time intervals for 30 days, and short-term 24 h continuous Holter ECG, in comparison with a no-screening alternative in 75-year-old patients with a recent ischaemic stroke. The long-term (20-year) costs and effects of all alternatives were estimated with a decision analytic model combining the result of a clinical study and epidemiological data from Sweden. The structure of a cost-effectiveness analysis was used in this study. The short-term decision tree model analysed the screening procedure until the onset of anticoagulant treatment. The second part of the decision model followed a Markov design, simulating the patients' health states for 20 years. Continuous 24 h ECG recording was inferior to intermittent ECG in terms of cost-effectiveness, due to both lower sensitivity and higher costs. The base-case analysis compared intermittent ECG screening with no screening of patients with recent stroke. The implementation of the screening programme on 1000 patients resulted over a 20-year period in 11 avoided strokes and the gain of 29 life-years, or 23 quality-adjusted life years, and cost savings of €55 400. Screening of silent AF by intermittent ECG recordings in patients with a recent ischaemic stroke is a cost-effective use of health care resources saving costs and lives and improving the quality of life. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  1. Computational challenges and human factors influencing the design and use of clinical research participant eligibility pre-screening tools

    PubMed Central

    2012-01-01

    Background Clinical trials are the primary mechanism for advancing clinical care and evidenced-based practice, yet challenges with the recruitment of participants for such trials are widely recognized as a major barrier to these types of studies. Data warehouses (DW) store large amounts of heterogenous clinical data that can be used to enhance recruitment practices, but multiple challenges exist when using a data warehouse for such activities, due to the manner of collection, management, integration, analysis, and dissemination of the data. A critical step in leveraging the DW for recruitment purposes is being able to match trial eligibility criteria to discrete and semi-structured data types in the data warehouse, though trial eligibility criteria tend to be written without concern for their computability. We present the multi-modal evaluation of a web-based tool that can be used for pre-screening patients for clinical trial eligibility and assess the ability of this tool to be practically used for clinical research pre-screening and recruitment. Methods The study used a validation study, usability testing, and a heuristic evaluation to evaluate and characterize the operational characteristics of the software as well as human factors affecting its use. Results Clinical trials from the Division of Cardiology and the Department of Family Medicine were used for this multi-modal evaluation, which included a validation study, usability study, and a heuristic evaluation. From the results of the validation study, the software demonstrated a positive predictive value (PPV) of 54.12% and 0.7%, respectively, and a negative predictive value (NPV) of 73.3% and 87.5%, respectively, for two types of clinical trials. Heuristic principles concerning error prevention and documentation were characterized as the major usability issues during the heuristic evaluation. Conclusions This software is intended to provide an initial list of eligible patients to a clinical study coordinators, which provides a starting point for further eligibility screening by the coordinator. Because this software has a high “rule in” ability, meaning that it is able to remove patients who are not eligible for the study, the use of an automated tool built to leverage an existing enterprise DW can be beneficial to determining eligibility and facilitating clinical trial recruitment through pre-screening. While the results of this study are promising, further refinement and study of this and related approaches to automated eligibility screening, including comparison to other approaches and stakeholder perceptions, are needed and future studies are planned to address these needs. PMID:22646313

  2. Computational challenges and human factors influencing the design and use of clinical research participant eligibility pre-screening tools.

    PubMed

    Pressler, Taylor R; Yen, Po-Yin; Ding, Jing; Liu, Jianhua; Embi, Peter J; Payne, Philip R O

    2012-05-30

    Clinical trials are the primary mechanism for advancing clinical care and evidenced-based practice, yet challenges with the recruitment of participants for such trials are widely recognized as a major barrier to these types of studies. Data warehouses (DW) store large amounts of heterogenous clinical data that can be used to enhance recruitment practices, but multiple challenges exist when using a data warehouse for such activities, due to the manner of collection, management, integration, analysis, and dissemination of the data. A critical step in leveraging the DW for recruitment purposes is being able to match trial eligibility criteria to discrete and semi-structured data types in the data warehouse, though trial eligibility criteria tend to be written without concern for their computability. We present the multi-modal evaluation of a web-based tool that can be used for pre-screening patients for clinical trial eligibility and assess the ability of this tool to be practically used for clinical research pre-screening and recruitment. The study used a validation study, usability testing, and a heuristic evaluation to evaluate and characterize the operational characteristics of the software as well as human factors affecting its use. Clinical trials from the Division of Cardiology and the Department of Family Medicine were used for this multi-modal evaluation, which included a validation study, usability study, and a heuristic evaluation. From the results of the validation study, the software demonstrated a positive predictive value (PPV) of 54.12% and 0.7%, respectively, and a negative predictive value (NPV) of 73.3% and 87.5%, respectively, for two types of clinical trials. Heuristic principles concerning error prevention and documentation were characterized as the major usability issues during the heuristic evaluation. This software is intended to provide an initial list of eligible patients to a clinical study coordinators, which provides a starting point for further eligibility screening by the coordinator. Because this software has a high "rule in" ability, meaning that it is able to remove patients who are not eligible for the study, the use of an automated tool built to leverage an existing enterprise DW can be beneficial to determining eligibility and facilitating clinical trial recruitment through pre-screening. While the results of this study are promising, further refinement and study of this and related approaches to automated eligibility screening, including comparison to other approaches and stakeholder perceptions, are needed and future studies are planned to address these needs.

  3. The Accutension Stetho, an automated auscultatory device to validate automated sphygmomanometer readings in individual patients.

    PubMed

    Alpert, Bruce S

    2018-04-06

    The aim of this report is to describe a new device that can validate, by automated auscultation, individual blood pressure (BP) readings taken by automated sphygmomanometers.The Accutension Stetho utilizes a smartphone application in conjunction with a specially designed stethoscope that interfaces directly into the smartphone via the earphone jack. The Korotkoff sounds are recorded by the application and are analyzed by the operator on the screen of the smartphone simultaneously with the images from the sphygmomanometer screen during BP estimation. Current auscultatory validation standards require at least 85 subjects and strict statistical criteria for passage. A device that passes can make no guarantee of accuracy on individual patients. The Accutension Stetho is an inexpensive smartphone/stethoscope kit combination that estimates precise BP values by auscultation to confirm the accuracy of an automated sphygmomanometer's readings on individual patients. This should be of great value for both professional and, in certain circumstances, self-measurement BP. Patients will avoid both unnecessary treatment and errors of underestimation of BP, in which the patient requires therapy. The Stetho's software has been validated in an independent ANSI/AAMI/ISO standard study. The Stetho has been shown to perform without difficulty in multiple deflation-based devices by many manufacturers.

  4. Assessing collaborative computing: development of the Collaborative-Computing Observation Instrument (C-COI)

    NASA Astrophysics Data System (ADS)

    Israel, Maya; Wherfel, Quentin M.; Shehab, Saadeddine; Ramos, Evan A.; Metzger, Adam; Reese, George C.

    2016-07-01

    This paper describes the development, validation, and uses of the Collaborative Computing Observation Instrument (C-COI), a web-based analysis instrument that classifies individual and/or collaborative behaviors of students during computing problem-solving (e.g. coding, programming). The C-COI analyzes data gathered through video and audio screen recording software that captures students' computer screens as they program, and their conversations with their peers or adults. The instrument allows researchers to organize and quantify these data to track behavioral patterns that could be further analyzed for deeper understanding of persistence and/or collaborative interactions. The article provides a rationale for the C-COI including the development of a theoretical framework for measuring collaborative interactions in computer-mediated environments. This theoretical framework relied on the computer-supported collaborative learning literature related to adaptive help seeking, the joint problem-solving space in which collaborative computing occurs, and conversations related to outcomes and products of computational activities. Instrument development and validation also included ongoing advisory board feedback from experts in computer science, collaborative learning, and K-12 computing as well as classroom observations to test out the constructs in the C-COI. These processes resulted in an instrument with rigorous validation procedures and a high inter-rater reliability.

  5. Guidance and Control Software Project Data - Volume 3: Verification Documents

    NASA Technical Reports Server (NTRS)

    Hayhurst, Kelly J. (Editor)

    2008-01-01

    The Guidance and Control Software (GCS) project was the last in a series of software reliability studies conducted at Langley Research Center between 1977 and 1994. The technical results of the GCS project were recorded after the experiment was completed. Some of the support documentation produced as part of the experiment, however, is serving an unexpected role far beyond its original project context. Some of the software used as part of the GCS project was developed to conform to the RTCA/DO-178B software standard, "Software Considerations in Airborne Systems and Equipment Certification," used in the civil aviation industry. That standard requires extensive documentation throughout the software development life cycle, including plans, software requirements, design and source code, verification cases and results, and configuration management and quality control data. The project documentation that includes this information is open for public scrutiny without the legal or safety implications associated with comparable data from an avionics manufacturer. This public availability has afforded an opportunity to use the GCS project documents for DO-178B training. This report provides a brief overview of the GCS project, describes the 4-volume set of documents and the role they are playing in training, and includes the verification documents from the GCS project. Volume 3 contains four appendices: A. Software Verification Cases and Procedures for the Guidance and Control Software Project; B. Software Verification Results for the Pluto Implementation of the Guidance and Control Software; C. Review Records for the Pluto Implementation of the Guidance and Control Software; and D. Test Results Logs for the Pluto Implementation of the Guidance and Control Software.

  6. 48 CFR 252.204-7014 - Limitations on the Use or Disclosure of Information by Litigation Support Contractors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Computer software does not include computer data bases or computer software documentation. Litigation... includes technical data and computer software, but does not include information that is lawfully, publicly available without restriction. Technical data means recorded information, regardless of the form or method...

  7. 25 CFR 543.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... software upgrades, data storage media replacement, etc.). The information recorded must be used when...., draw objects and back-up draw objects); and (ii) Random number generator software. (Additional information technology security standards can be found in § 543.16 of this part.) (2) The game software...

  8. 25 CFR 543.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... software upgrades, data storage media replacement, etc.). The information recorded must be used when...., draw objects and back-up draw objects); and (ii) Random number generator software. (Additional information technology security standards can be found in § 543.16 of this part.) (2) The game software...

  9. 32 CFR 295.3 - Definition of OIG records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., decisions, or procedures of the OIG. Normally, computer software, including source code, object code, and... the underlying data which is processed and produced by such software and which may in some instances be stored with the software.) Exceptions to this position are outlined in § 295.4(c). (3) Anything...

  10. 32 CFR 295.3 - Definition of OIG records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., decisions, or procedures of the OIG. Normally, computer software, including source code, object code, and... the underlying data which is processed and produced by such software and which may in some instances be stored with the software.) Exceptions to this position are outlined in § 295.4(c). (3) Anything...

  11. 32 CFR 295.3 - Definition of OIG records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., decisions, or procedures of the OIG. Normally, computer software, including source code, object code, and... the underlying data which is processed and produced by such software and which may in some instances be stored with the software.) Exceptions to this position are outlined in § 295.4(c). (3) Anything...

  12. 32 CFR 295.3 - Definition of OIG records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., decisions, or procedures of the OIG. Normally, computer software, including source code, object code, and... the underlying data which is processed and produced by such software and which may in some instances be stored with the software.) Exceptions to this position are outlined in § 295.4(c). (3) Anything...

  13. 32 CFR 295.3 - Definition of OIG records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., decisions, or procedures of the OIG. Normally, computer software, including source code, object code, and... the underlying data which is processed and produced by such software and which may in some instances be stored with the software.) Exceptions to this position are outlined in § 295.4(c). (3) Anything...

  14. 12 CFR 749.3 - Vital records center.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....3 Vital records center. A vital records center is defined as a storage facility, which may include... must maintain or contract with a third party to maintain any equipment or software for its vital...

  15. 12 CFR 749.3 - Vital records center.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....3 Vital records center. A vital records center is defined as a storage facility, which may include... must maintain or contract with a third party to maintain any equipment or software for its vital...

  16. 12 CFR 749.3 - Vital records center.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....3 Vital records center. A vital records center is defined as a storage facility, which may include... must maintain or contract with a third party to maintain any equipment or software for its vital...

  17. 12 CFR 749.3 - Vital records center.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....3 Vital records center. A vital records center is defined as a storage facility, which may include... must maintain or contract with a third party to maintain any equipment or software for its vital...

  18. 12 CFR 749.3 - Vital records center.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....3 Vital records center. A vital records center is defined as a storage facility, which may include... must maintain or contract with a third party to maintain any equipment or software for its vital...

  19. PRISM, Processing and Review Interface for Strong Motion Data Software

    NASA Astrophysics Data System (ADS)

    Kalkan, E.; Jones, J. M.; Stephens, C. D.; Ng, P.

    2016-12-01

    A continually increasing number of high-quality digital strong-motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the U.S., calls for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. PRISM automates the processing of strong-motion records by providing batch-processing capabilities. The PRISM software is platform-independent (coded in Java), open-source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a graphical user interface (GUI) for manual review and processing. To facilitate the use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and GUI components) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X and Windows. PRISM was designed to be flexible and extensible in order to accommodate implementation of new processing techniques. Input to PRISM currently is limited to data files in the Consortium of Organizations for Strong-Motion Observation Systems (COSMOS) V0 format, so that all retrieved acceleration time series need to be converted to this format. Output products include COSMOS V1, V2 and V3 files as: (i) raw acceleration time series in physical units with mean removed (V1), (ii) baseline-corrected and filtered acceleration, velocity, and displacement time series (V2), and (iii) response spectra, Fourier amplitude spectra and common earthquake-engineering intensity measures (V3). A thorough description of the record processing features supported by PRISM is presented with examples and validation results. All computing features have been thoroughly tested.

  20. Strategies for Using Plagiarism Software in the Screening of Incoming Journal Manuscripts: Recommendations Based on a Recent Literature Survey.

    PubMed

    Lykkesfeldt, Jens

    2016-08-01

    In recent years, several online tools have appeared capable of identifying potential plagiarism in science. While such tools may help to maintain or even increase the originality and ethical quality of the scientific literature, no apparent consensus exists among editors on the degree of plagiarism or self-plagiarism necessary to reject or retract manuscripts. In this study, two entire volumes of published original papers and reviews from Basic & Clinical Pharmacology & Toxicology were retrospectively scanned for similarity in anonymized form using iThenticate software to explore measures to predictively identify true plagiarism and self-plagiarism and to potentially provide guidelines for future screening of incoming manuscripts. Several filters were applied, all of which appeared to lower the noise from irrelevant hits. The main conclusions were that plagiarism software offers a unique opportunity to screen for plagiarism easily but also that it has to be employed with caution as automated or uncritical use is far too unreliable to allow a fair basis for judging the degree of plagiarism in a manuscript. This remains the job of senior editors. Whereas a few cases of self-plagiarism that would not likely have been accepted with today's guidelines were indeed identified, no cases of fraud or serious plagiarism were found. Potential guidelines are discussed. © 2016 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  1. Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings.

    PubMed

    Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S

    2015-02-01

    The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia. © 2014 John Wiley & Sons Ltd.

  2. gr-MRI: A software package for magnetic resonance imaging using software defined radios

    NASA Astrophysics Data System (ADS)

    Hasselwander, Christopher J.; Cao, Zhipeng; Grissom, William A.

    2016-09-01

    The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5 Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately 2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500 kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs.

  3. Deriving the Cost of Software Maintenance for Software Intensive Systems

    DTIC Science & Technology

    2011-08-29

    more of software maintenance). Figure 4. SEER-SEM Maintenance Effort by Year Report (Reifer, Allen, Fersch, Hitchings, Judy , & Rosa, 2010...understand the linear relationship between two variables. The formula for the simple Pearson product-moment correlation is represented in Equation 5...standardization is required across the software maintenance community in order to ensure that the data being recorded can be employed beyond the agency or

  4. Studying Upper-Limb Amputee Prosthesis Use to Inform Device Design

    DTIC Science & Technology

    2016-10-01

    study of the resulting videos led to a new prosthetics-use taxonomy that is generalizable to various levels of amputation and terminal devices. The...taxonomy was applied to classification of the recorded videos via custom tagging software with midi controller interface. The software creates...a motion capture studio and video cameras to record accurate and detailed upper body motion during a series of standardized tasks. These tasks are

  5. [Assessment of a software application tool for managing nursing care processes in the period 2005-2010].

    PubMed

    Medina-Valverde, M José; Rodríguez-Borrego, M Aurora; Luque-Alcaraz, Olga; de la Torre-Barbero, M José; Parra-Perea, Julia; Moros-Molina, M del Pilar

    2012-01-01

    To identify problems and critical points in the software application. Assessment of the implementation of the software tool "Azahar" used to manage nursing care processes. The monitored population consisted of nurses who were users of the tool, at the Hospital and those who benefited from it in Primary Care. Each group was selected randomly and the number was determined by data saturation. A qualitative approach was employed using in-depth interviews and group discussion as data collection techniques. The nurses considered that the most beneficial and useful application of the tool was the initial assessment and the continuity of care release forms, as well as the recording of all data on the nursing process to ensure quality. The disadvantages and weaknesses identified were associated with the continuous variability in their daily care. The nurses related an increase in workload with the impossibility of entering the records into the computer, making paper records, thus duplicating the recording process. Likewise, they consider that the operating system of the software should be improved in terms of simplicity and functionality. The simplicity of the tool and the adjustment of workloads would favour its use and as a result, continuity of care. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  6. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes.

    PubMed

    Popelka, Stanislav; Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe.

  7. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes

    PubMed Central

    Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe. PMID:27087805

  8. 15. Photographic copy of construction drawing DP28827 (from record group ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Photographic copy of construction drawing DP-28827 (from record group of Civil Engineering, Hill Air Force Base, Utah). Dec. 16, 1940. 8x10 negative and print. STANDARD BLACK POWDER SCREENING BUILDING. ROOF FRAMING PLAN & DETAILS. - Ogden Arsenal, Black Powder Screening Building, 7745 Navajo Way, Layton, Davis County, UT

  9. An Electronic Health Record Data-driven Model for Identifying Older Adults at Risk of Unintentional Falls

    PubMed Central

    Baus, Adam; Coben, Jeffrey; Zullig, Keith; Pollard, Cecil; Mullett, Charles; Taylor, Henry; Cochran, Jill; Jarrett, Traci; Long, Dustin

    2017-01-01

    Screening for risk of unintentional falls remains low in the primary care setting because of the time constraints of brief office visits. National studies suggest that physicians caring for older adults provide recommended fall risk screening only 30 to 37 percent of the time. Given prior success in developing methods for repurposing electronic health record data for the identification of fall risk, this study involves building a model in which electronic health record data could be applied for use in clinical decision support to bolster screening by proactively identifying patients for whom screening would be beneficial and targeting efforts specifically to those patients. The final model, consisting of priority and extended measures, demonstrates moderate discriminatory power, indicating that it could prove useful in a clinical setting for identifying patients at risk of falls. Focus group discussions reveal important contextual issues involving the use of fall-related data and provide direction for the development of health systems–level innovations for the use of electronic health record data for fall risk identification. PMID:29118679

  10. A Symphony of Software.

    ERIC Educational Resources Information Center

    Currents, 2002

    2002-01-01

    Offers a descriptive table of databases that help higher education institutions orchestrate advancement operations. Information includes vendor, contact, software, price, database engine/server platform, recommended reporting tools, record capacity, and client type. (EV)

  11. Military Health Service System Ambulatory Work Unit (AWU).

    DTIC Science & Technology

    1988-04-01

    E-40 BBC-4 Ambulatory Work Unit Distribution Screen Passes BBC - Neurosurgery Clinic .... ............. . E-40 BBD -I Initial Record...Screen Failures BBD - Ophthalmology Clinic ... ............ E-41 BBD -2 Distribution Screen Failures BBD - Ophthalmology Clinic ............ E-41 BBD -3...Descriptive Statistics Distribution Screen Passes BBD - Ophthalmology Clinic ............ E-42 BBD -4 Ambulatory Work Unit Distribution Screen Passes BBD

  12. Mothers' screening histories influence daughters' vaccination uptake: an analysis of linked cervical screening and human papillomavirus vaccination records in the North West of England.

    PubMed

    Spencer Nee Pilkington, Angela M; Brabin, Loretta; Verma, Arpana; Roberts, Stephen A

    2013-04-01

    Achieving high human papillomavirus (HPV) vaccine coverage is important because cervical screening coverage is declining. As key decision makers, mothers' experiences of, and participation in, the cervical screening programme could affect vaccination consent. We investigate whether mother's screening history influences daughter's participation in the HPV vaccination programme. Mothers' cervical screening records from the National Health Authority Information System were linked to the daughters' HPV vaccination records from the Child Health System in North West England by address. Odds ratios for daughter's vaccination were computed using Logistic Regression, adjusting for age, Primary Care Trust and vaccine cohort (AOR). Daughters in both the routine and catch up programmes were more likely to have initiated vaccination and completed the course if their mothers had attended screening. The association was strongest when mothers had attended within the last 5 years (AOR in routine group: 3.5 (95% confidence interval (CI) 3.1-4.0) for initiation and 2.2 (1.6-2.9) for retention). Mothers who had personally decided to cease screening were less likely to have vaccinated daughters than those who had ceased for medical indications. Daughters were more likely to have been vaccinated if their mothers had received an abnormal smear result. Daughter's HPV vaccination uptake was associated with mother's cervical screening attendance. Daughters of mothers who are not engaged with preventive services are less likely to be vaccinated and may be less likely to engage with screening. This makes mothers central to health interventions to promote both cervical screening and HPV vaccination. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. An interactive, multi-touch videowall for scientific data exploration

    NASA Astrophysics Data System (ADS)

    Blower, Jon; Griffiths, Guy; van Meersbergen, Maarten; Lusher, Scott; Styles, Jon

    2014-05-01

    The use of videowalls for scientific data exploration is rising as hardware becomes cheaper and the availability of software and multimedia content grows. Most videowalls are used primarily for outreach and communication purposes, but there is increasing interest in using large display screens to support exploratory visualization as an integral part of scientific research. In this PICO presentation we will present a brief overview of a new videowall system at the University of Reading, which is designed specifically to support interactive, exploratory visualization activities in climate science and Earth Observation. The videowall consists of eight 42-inch full-HD screens (in 4x2 formation), giving a total resolution of about 16 megapixels. The display is managed by a videowall controller, which can direct video to the screen from up to four external laptops, a purpose-built graphics workstation, or any combination thereof. A multi-touch overlay provides the capability for the user to interact directly with the data. There are many ways to use the videowall, and a key technical challenge is to make the most of the touch capabilities - touch has the potential to greatly reduce the learning curve in interactive data exploration, but most software is not yet designed for this purpose. In the PICO we will present an overview of some ways in which the wall can be employed in science, seeking feedback and discussion from the community. The system was inspired by an existing and highly-successful system (known as the "Collaboratorium") at the Netherlands e-Science Center (NLeSC). We will demonstrate how we have adapted NLeSC's visualization software to our system for touch-enabled multi-screen climate data exploration.

  14. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    PubMed

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  15. From cheminformatics to structure-based design: Web services and desktop applications based on the NAOMI library.

    PubMed

    Bietz, Stefan; Inhester, Therese; Lauck, Florian; Sommer, Kai; von Behren, Mathias M; Fährrolfes, Rainer; Flachsenberg, Florian; Meyder, Agnes; Nittinger, Eva; Otto, Thomas; Hilbig, Matthias; Schomburg, Karen T; Volkamer, Andrea; Rarey, Matthias

    2017-11-10

    Nowadays, computational approaches are an integral part of life science research. Problems related to interpretation of experimental results, data analysis, or visualization tasks highly benefit from the achievements of the digital era. Simulation methods facilitate predictions of physicochemical properties and can assist in understanding macromolecular phenomena. Here, we will give an overview of the methods developed in our group that aim at supporting researchers from all life science areas. Based on state-of-the-art approaches from structural bioinformatics and cheminformatics, we provide software covering a wide range of research questions. Our all-in-one web service platform ProteinsPlus (http://proteins.plus) offers solutions for pocket and druggability prediction, hydrogen placement, structure quality assessment, ensemble generation, protein-protein interaction classification, and 2D-interaction visualization. Additionally, we provide a software package that contains tools targeting cheminformatics problems like file format conversion, molecule data set processing, SMARTS editing, fragment space enumeration, and ligand-based virtual screening. Furthermore, it also includes structural bioinformatics solutions for inverse screening, binding site alignment, and searching interaction patterns across structure libraries. The software package is available at http://software.zbh.uni-hamburg.de. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. The Western Aeronautical Test Range. Chapter 10 Tools

    NASA Technical Reports Server (NTRS)

    Knudtson, Kevin; Park, Alice; Downing, Robert; Sheldon, Jack; Harvey, Robert; Norcross, April

    2011-01-01

    The Western Aeronautical Test Range (WATR) staff at the NASA Dryden Flight Research Center is developing a translation software called Chapter 10 Tools in response to challenges posed by post-flight processing data files originating from various on-board digital recorders that follow the Range Commanders Council Inter-Range Instrumentation Group (IRIG) 106 Chapter 10 Digital Recording Standard but use differing interpretations of the Standard. The software will read the date files regardless of the vendor implementation of the source recorder, displaying data, identifying and correcting errors, and producing a data file that can be successfully processed post-flight

  17. GAPscreener: an automatic tool for screening human genetic association literature in PubMed using the support vector machine technique.

    PubMed

    Yu, Wei; Clyne, Melinda; Dolan, Siobhan M; Yesupriya, Ajay; Wulf, Anja; Liu, Tiebin; Khoury, Muin J; Gwinn, Marta

    2008-04-22

    Synthesis of data from published human genetic association studies is a critical step in the translation of human genome discoveries into health applications. Although genetic association studies account for a substantial proportion of the abstracts in PubMed, identifying them with standard queries is not always accurate or efficient. Further automating the literature-screening process can reduce the burden of a labor-intensive and time-consuming traditional literature search. The Support Vector Machine (SVM), a well-established machine learning technique, has been successful in classifying text, including biomedical literature. The GAPscreener, a free SVM-based software tool, can be used to assist in screening PubMed abstracts for human genetic association studies. The data source for this research was the HuGE Navigator, formerly known as the HuGE Pub Lit database. Weighted SVM feature selection based on a keyword list obtained by the two-way z score method demonstrated the best screening performance, achieving 97.5% recall, 98.3% specificity and 31.9% precision in performance testing. Compared with the traditional screening process based on a complex PubMed query, the SVM tool reduced by about 90% the number of abstracts requiring individual review by the database curator. The tool also ascertained 47 articles that were missed by the traditional literature screening process during the 4-week test period. We examined the literature on genetic associations with preterm birth as an example. Compared with the traditional, manual process, the GAPscreener both reduced effort and improved accuracy. GAPscreener is the first free SVM-based application available for screening the human genetic association literature in PubMed with high recall and specificity. The user-friendly graphical user interface makes this a practical, stand-alone application. The software can be downloaded at no charge.

  18. Roles of the eye care workforce for task sharing in management of diabetic retinopathy in Cambodia

    PubMed Central

    Shah, Mufarriq; Ormsby, Gail M.; Noor, Ayesha; Chakrabarti, Rahul; Mörchen, Manfred; Islam, Fakir M Amirul; Harper, C Alex; Keeffe, Jill E

    2018-01-01

    AIM To identify the current roles of eye and health care workers in eye care delivery and investigate their potential roles in screening and detection for management of diabetic retinopathy (DR) through task sharing. METHODS Purposive sampling of 24 participants including health administrators, members from non-government organizations and all available eye care workers in Takeo province were recruited. This cross sectional mixed method study comprised a survey and in-depth interviews. Data were collected from medical records at Caritas Takeo Eye Hospital (CTEH) and Kiri Vong District Referral Hospital Vision Centre, and a survey and interviews with participants were done to explore the potential roles for task sharing in DR management. Qualitative data were transcribed into a text program and then entered into N-Vivo (version 10) software for data management and analysis. RESULTS From 2009 to 2012, a total of 105 178 patients were examined and 14 030 eye surgeries were performed in CTEH by three ophthalmologists supported by ophthalmic nurses in operating and eye examination for patients. Between January 2011 and September 2012, 151 patients (72 males) with retinal pathology including 125 (83%) with DR visited CTEH. In addition 170 patients with diabetes were referred to CTEH for eye examinations from Mo Po Tsyo screening programs for people with diabetes. Factors favouring task sharing included high demand for eye care services and scarcity of ophthalmologists. CONCLUSION Task sharing and team work for eye care services is functional. Participants favor the potential role of ophthalmic nurses in screening for DR through task sharing. PMID:29375999

  19. Attitudes of physicians, patients, and village health workers toward glaucoma and diabetic retinopathy in rural China: a focus group study.

    PubMed

    Yan, Xixi; Liu, Tianyu; Gruber, Layla; He, Mingguang; Congdon, Nathan

    2012-06-01

    OBJECTIVE To understand the knowledge and attitudes of rural Chinese physicians, patients, and village health workers (VHWs) toward diabetic eye disease and glaucoma. METHODS Focus groups for each of the 3 stakeholders were conducted in 3 counties (9 groups). The focus groups were recorded, transcribed, and coded using specialized software. Responses to questions about barriers to compliance and interventions to remove these barriers were also ranked and scored. RESULTS Among 22 physicians, 23 patients, and 25 VHWs, knowledge about diabetic eye disease was generally good, but physicians and patients understood glaucoma only as an acutely symptomatic disease of relatively low prevalence. Physicians did not favor routine pupillary dilation to detect asymptomatic disease, expressing concerns about workflow and danger and inconvenience to patients. Providers believed that cost was the main barrier to patient compliance, whereas patients ranked poorly trained physicians as more important. All 3 stakeholder groups ranked financial interventions to improve compliance (eg, direct payment, lotteries, and contracts) low and preferred patient education and telephone contact by nurses. All the groups somewhat doubted the ability of VHWs to screen for eye disease accurately, but patients were generally willing to pay for VHW screening. The VHWs were uncertain about the value of eye care training but might accept it if accompanied by equipment. They did not rank payment for screening services as important. CONCLUSIONS Misconceptions about glaucoma's asymptomatic nature and an unwillingness to routinely examine asymptomatic patients must be addressed in training programs. Home contact by nurses and patient education may be the most appropriate interventions to improve compliance.

  20. The use of a smartphone application for fast lung cancer risk assessment†.

    PubMed

    Szanto, Zalan; Benko, Istvan; Jakab, Laszlo; Szalai, Gabor; Vereczkei, Andras

    2017-06-01

    The overall prognosis of lung cancer is poor: Only every 8 patient survives 5 years after diagnosis. This outcome is partly attributable to late diagnosis. To implement a screening program for early diagnosis, selection of high-risk individuals is essential. Our aim was to construct a personalized lung cancer risk assessment tool using geographic localization to lead the high-risk individuals to the local health care provider. A smartphone application was created for Android and iOS mobile platforms using a risk assessment questionnaire. The software provides immediate classification into low, moderate and high-risk groups. The high-risk group is directed to the nearest screening centre based on GPS location. The complete test data set is recorded on a collection server database for further analysis. The application was downloaded 13 890 times and completed by 89 500 persons over a period of 20 months. The mean age of the tested users was 36.91 years (9-93 years); the majority were men living in an urban area (62.3%). The test was completed by 38 850 active smokers and 26 710 persons who reported having already quit smoking, resulting in 30 072 moderate and 10 740 high-risk users. This free application is an active communication tool for most smartphone owners. It helps those who might need further medical attention. The affected users can be easily connected and localized via the smartphone, which helps recruit individuals into screening programs. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  2. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  3. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  4. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  5. TOPEX SDR Processing, October 1998. Volume 4

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey E.; Lockwood, Dennis W.

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  6. Development of MATLAB software to control data acquisition from a multichannel systems multi-electrode array.

    PubMed

    Messier, Erik

    2016-08-01

    A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.

  7. Test Methods for Telemetry Systems and Subsystems. Volume 5: Test Methods for Digital Recorder/Reproducer Systems and Recorder Memory Modules

    DTIC Science & Technology

    2016-09-26

    serial communications program ( Hyper terminal) Configure METS for PCM 1 Mbps and MIL-STD-1553 10-Hz rate 4 Configure the host software to...Verify recorder stopped 44 Issue . LOOP . Verify recorder goes into record and play in read after write mode 45 Issue .STOP, Verify recorder

  8. VA's Integrated Imaging System on three platforms.

    PubMed

    Dayhoff, R E; Maloney, D L; Majurski, W J

    1992-01-01

    The DHCP Integrated Imaging System provides users with integrated patient data including text, image and graphics data. This system has been transferred from its original two screen DOS-based MUMPS platform to an X window workstation and a Microsoft Windows-based workstation. There are differences between these various platforms that impact on software design and on software development strategy. Data structures and conventions were used to isolate hardware, operating system, imaging software, and user-interface differences between platforms in the implementation of functionality for text and image display and interaction. The use of an object-oriented approach greatly increased system portability.

  9. VA's Integrated Imaging System on three platforms.

    PubMed Central

    Dayhoff, R. E.; Maloney, D. L.; Majurski, W. J.

    1992-01-01

    The DHCP Integrated Imaging System provides users with integrated patient data including text, image and graphics data. This system has been transferred from its original two screen DOS-based MUMPS platform to an X window workstation and a Microsoft Windows-based workstation. There are differences between these various platforms that impact on software design and on software development strategy. Data structures and conventions were used to isolate hardware, operating system, imaging software, and user-interface differences between platforms in the implementation of functionality for text and image display and interaction. The use of an object-oriented approach greatly increased system portability. PMID:1482983

  10. Smart roadside initiative : system design document.

    DOT National Transportation Integrated Search

    2015-09-01

    This document describes the software design for the Smart Roadside Initiative (SRI) for the delivery of capabilities related to wireless roadside inspections, electronic screening/virtual weigh stations, universal electronic commercial vehicle identi...

  11. Technical note: The US Dobson station network data record prior to 2015, re-evaluation of NDACC and WOUDC archived records with WinDobson processing software

    NASA Astrophysics Data System (ADS)

    Evans, Robert D.; Petropavlovskikh, Irina; McClure-Begley, Audra; McConville, Glen; Quincy, Dorothy; Miyagawa, Koji

    2017-10-01

    The United States government has operated Dobson ozone spectrophotometers at various sites, starting during the International Geophysical Year (1 July 1957 to 31 December 1958). A network of stations for long-term monitoring of the total column content (thickness of the ozone layer) of the atmosphere was established in the early 1960s and eventually grew to 16 stations, 14 of which are still operational and submit data to the United States of America's National Oceanic and Atmospheric Administration (NOAA). Seven of these sites are also part of the Network for the Detection of Atmospheric Composition Change (NDACC), an organization that maintains its own data archive. Due to recent changes in data processing software the entire dataset was re-evaluated for possible changes. To evaluate and minimize potential changes caused by the new processing software, the reprocessed data record was compared to the original data record archived in the World Ozone and UV Data Center (WOUDC) in Toronto, Canada. The history of the observations at the individual stations, the instruments used for the NOAA network monitoring at the station, the method for reducing zenith-sky observations to total ozone, and calibration procedures were re-evaluated using data quality control tools built into the new software. At the completion of the evaluation, the new datasets are to be published as an update to the WOUDC and NDACC archives, and the entire dataset is to be made available to the scientific community. The procedure for reprocessing Dobson data and the results of the reanalysis on the archived record are presented in this paper. A summary of historical changes to 14 station records is also provided.

  12. Endocrine Disruptor Screening Program Tier 1 Assessments

    EPA Pesticide Factsheets

    EPA has completed weight-of-evidence (WoE) assessments under the Endocrine Distruptor Screening Program (EDSP) for 52 pesticides included in the final list of chemicals for Tier 1 screening. See weight of evidence reports and data evaluation records.

  13. Development of x-ray imaging technique for liquid screening at airport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sulaiman, Nurhani binti, E-mail: nhani.sulaiman@gmail.com; Srisatit, Somyot, E-mail: somyot.s@chula.ac.th

    2016-01-22

    X-ray imaging technology is a viable option to recognize flammable liquids for the purposes of aviation security. In this study, an X-ray imaging technology was developed whereby, the image viewing system was built with the use of a digital camera coupled with a gadolinium oxysulfide (GOS) fluorescent screen. The camera was equipped with a software for remote control setting of the camera via a USB cable which allows the images to be captured. The image was analysed to determine the average grey level using a software designed by Microsoft Visual Basic 6.0. The data was obtained for various densities ofmore » liquid thickness of 4.5 cm, 6.0 cm and 7.5 cm respectively for X-ray energies ranging from 70 to 200 kVp. In order to verify the reliability of the constructed calibration data, the system was tested with a few types of unknown liquids. The developed system could be conveniently employed for security screening in order to discriminate between a threat and an innocuous liquid.« less

  14. Impact of socioeconomic deprivation on screening for cardiovascular disease risk in a primary prevention population: a cross-sectional study.

    PubMed

    Lang, Sarah-Jane; Abel, Gary A; Mant, Jonathan; Mullis, Ricky

    2016-03-21

    Investigate the association between socioeconomic deprivation and completeness of cardiovascular disease (CVD) risk factor recording in primary care, uptake of screening in people with incomplete risk factor recording and with actual CVD risk within the screened subgroup. Cross-sectional study. Nine UK general practices. 7987 people aged 50-74 years with no CVD diagnosis. CVD risk was estimated using the Framingham equation from data extracted from primary care electronic health records. Where there was insufficient information to calculate risk, patients were invited to attend a screening assessment. Proportion of patients for whom clinical data were sufficiently complete to enable CVD risk to be calculated; proportion of patients invited to screening who attended; proportion of patients who attended screening whose 10-year risk of a cardiovascular event was high (>20%). For each outcome, a set of logistic regression models were run. Crude and adjusted ORs were estimated for person-level deprivation, age, gender and smoking status. We included practice-level deprivation as a continuous variable and practice as a random effect to account for clustering. People who had lower Indices of Multiple Deprivation (IMD) scores (less deprived) had significantly worse routine CVD risk factor recording (adjusted OR 0.97 (0.95 to 1.00) per IMD decile; p=0.042). Screening attendance was poorer in those with more deprivation (adjusted OR 0.89 (0.86 to 0.91) per IMD decile; p<0.001). Among those who attended screening, the most deprived were more likely to have CVD risk >20% (OR 1.09 (1.03 to 1.15) per IMD decile; p=0.004). Our data suggest that those who had the most to gain from screening were least likely to attend, potentially exacerbating existing health inequalities. Future research should focus on tailoring the delivery of CVD screening to ensure engagement of socioeconomically deprived groups. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Clinical records anonymisation and text extraction (CRATE): an open-source software system.

    PubMed

    Cardinal, Rudolf N

    2017-04-26

    Electronic medical records contain information of value for research, but contain identifiable and often highly sensitive confidential information. Patient-identifiable information cannot in general be shared outside clinical care teams without explicit consent, but anonymisation/de-identification allows research uses of clinical data without explicit consent. This article presents CRATE (Clinical Records Anonymisation and Text Extraction), an open-source software system with separable functions: (1) it anonymises or de-identifies arbitrary relational databases, with sensitivity and precision similar to previous comparable systems; (2) it uses public secure cryptographic methods to map patient identifiers to research identifiers (pseudonyms); (3) it connects relational databases to external tools for natural language processing; (4) it provides a web front end for research and administrative functions; and (5) it supports a specific model through which patients may consent to be contacted about research. Creation and management of a research database from sensitive clinical records with secure pseudonym generation, full-text indexing, and a consent-to-contact process is possible and practical using entirely free and open-source software.

  16. Method and system for rendering and interacting with an adaptable computing environment

    DOEpatents

    Osbourn, Gordon Cecil [Albuquerque, NM; Bouchard, Ann Marie [Albuquerque, NM

    2012-06-12

    An adaptable computing environment is implemented with software entities termed "s-machines", which self-assemble into hierarchical data structures capable of rendering and interacting with the computing environment. A hierarchical data structure includes a first hierarchical s-machine bound to a second hierarchical s-machine. The first hierarchical s-machine is associated with a first layer of a rendering region on a display screen and the second hierarchical s-machine is associated with a second layer of the rendering region overlaying at least a portion of the first layer. A screen element s-machine is linked to the first hierarchical s-machine. The screen element s-machine manages data associated with a screen element rendered to the display screen within the rendering region at the first layer.

  17. A web implementation: the good and the not-so-good.

    PubMed

    Bergsneider, C; Piraino, D; Fuerst, M

    2001-06-01

    E-commerce, e-mail, e-greeting, e-this, and e-that everywhere you turn there is a new "e" word for an internet or Web application. We, at the Cleveland Clinic Foundation, have been "e-nlightened" and will discuss in this report the implementation of a web-based radiology information system (RIS) in our radiology division or "e-radiology" division. The application, IDXRad Version 10.0 from IDX Corp, Burlington, VT, is in use at the Cleveland Clinic Foundation and has both intranet (for use in Radiology) and internet (referring physician viewing) modules. We will concentrate on the features of using a web browser for the application's front-end, including easy prototyping for screen review, easier mock-ups of demonstrations by vendors and developers, and easier training as more people become web-addicted. Project communication can be facilitated with an internal project web page, and use of the web browser can accommodate quicker turnaround of software upgrades as the software code is centrally located. Compared with other technologies, including client/server, there is a smaller roll out cost when using a standard web browser. However, the new technology requires a change and changes are never implemented without challenges. A seasoned technologist using a legacy system can enter data quicker using function keys than using a graphical user interface and pointing and clicking through a series of pop-up windows. Also, effective use of a web browser depends on intuitive design for it to be easily implemented and accepted by the user. Some software packages will not work on both of the popular web browsers and then are tailored to specific release levels. As computer-based patient records become a standard, patient confidentiality must be enforced. The technical design and application security features that support the web-based software package will be discussed. Also web technologies have their own implementation issues.

  18. ScreenMasker: An Open-source Gaze-contingent Screen Masking Environment.

    PubMed

    Orlov, Pavel A; Bednarik, Roman

    2016-09-01

    The moving-window paradigm, based on gazecontingent technic, traditionally used in a studies of the visual perceptual span. There is a strong demand for new environments that could be employed by non-technical researchers. We have developed an easy-to-use tool with a graphical user interface (GUI) allowing both execution and control of visual gaze-contingency studies. This work describes ScreenMasker, an environment that allows create gaze-contingent textured displays used together with stimuli presentation software. ScreenMasker has an architecture that meets the requirements of low-latency real-time eye-movement experiments. It also provides a variety of settings and functions. Effective rendering times and performance are ensured by means of GPU processing under CUDA technology. Performance tests show ScreenMasker's latency to be 67-74 ms on a typical office computer, and high-end 144-Hz screen latencies of about 25-28 ms. ScreenMasker is an open-source system distributed under the GNU Lesser General Public License and is available at https://github.com/PaulOrlov/ScreenMasker .

  19. Waveform Generator Signal Processing Software

    DOT National Transportation Integrated Search

    1988-09-01

    This report describes the software that was developed to process test waveforms that were recorded by crash test data acquisition systems. The test waveforms are generated by an electronic waveform generator developed by MGA Research Corporation unde...

  20. Proceedings of the 19th Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of applications software. The goals of the SEL are: (1) to understand the software development process in the GSFC environment; (2) to measure the effects of various methodologies, tools, and models on this process; and (3) to identify and then to apply successful development practices. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that include this document.

  1. Automated, Quantitative Cognitive/Behavioral Screening of Mice: For Genetics, Pharmacology, Animal Cognition and Undergraduate Instruction

    PubMed Central

    Gallistel, C. R.; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-01-01

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer. PMID:24637442

  2. Automated, quantitative cognitive/behavioral screening of mice: for genetics, pharmacology, animal cognition and undergraduate instruction.

    PubMed

    Gallistel, C R; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-02-26

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer.

  3. Software manual for operating particle displacement tracking data acquisition and reduction system

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.

    1991-01-01

    The software manual is presented. The necessary steps required to record, analyze, and reduce Particle Image Velocimetry (PIV) data using the Particle Displacement Tracking (PDT) technique are described. The new PDT system is an all electronic technique employing a CCD video camera and a large memory buffer frame-grabber board to record low velocity (less than or equal to 20 cm/s) flows. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine 2-D velocity vectors. All the PDT data acquisition, analysis, and data reduction software is written to run on an 80386 PC.

  4. [The planning of resource support of secondary medical care in hospital].

    PubMed

    Kungurov, N V; Zil'berberg, N V

    2010-01-01

    The Ural Institute of dermatovenerology and immunopathology developed and implemented the software concerning the personalized total recording of medical services and pharmaceuticals. The Institute also presents such software as listing of medical services, software module of calculation of financial costs of implementing full standards of secondary medical care in case of chronic dermatopathy, reference book of standards of direct specific costs on laboratory and physiotherapy services, reference book of pharmaceuticals, testing systems and consumables. The unified information system of management recording is a good technique to substantiate the costs of the implementation of standards of medical care, including high-tech care with taking into account the results of total calculation of provided medical services.

  5. Development of the electronic health records for nursing education (EHRNE) software program.

    PubMed

    Kowitlawakul, Yanika; Wang, Ling; Chan, Sally Wai-Chi

    2013-12-01

    This paper outlines preliminary research of an innovative software program that enables the use of an electronic health record in a nursing education curriculum. The software application program is called EHRNE, which stands for Electronic Heath Record for Nursing Education. The aim of EHRNE is to enhance student's learning of health informatics when they are working in the simulation laboratory. Integrating EHRNE into the nursing curriculum exposes students to electronic health records before they go into the workplace. A qualitative study was conducted using focus group interviews of nine nursing students. Nursing students' perceptions of using the EHRNE application were explored. The interviews were audio-taped and transcribed verbatim. The data was analyzed following the Colaizzi (1978) guideline. Four main categories that related to the EHRNE application were identified from the interviews: functionality, data management, timing and complexity, and accessibility. The analysis of the data revealed advantages and limitations of using EHRNE in the classroom setting. Integrating the EHRNE program into the curriculum will promote students' awareness of electronic documentation and enhance students' learning in the simulation laboratory. Preliminary findings suggested that before integrating the EHRNE program into the nursing curriculum, educational sessions for both students and faculty outlining the software's purpose, advantages, and limitations were needed. Following the educational sessions, further investigation of students' perceptions and learning using the EHRNE program is recommended. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Examining the Role of Electronic Medical Record Generated Provider Reminders on Provider Offering of Breast Cancer Screening Services

    ERIC Educational Resources Information Center

    Beverley, Charles St. Clare, Jr.

    2013-01-01

    Introduction: Breast cancer affects the lives of millions of women each year in the United States. Early detection by mammography screening can reduce the risk for advanced stages of breast cancer and improve the probability of long-term survival in women. Electronic medical records (EMRs) have been identified as a successful approach for…

  7. Pointright: a system to redirect mouse and keyboard control among multiple machines

    DOEpatents

    Johanson, Bradley E [Palo Alto, CA; Winograd, Terry A [Stanford, CA; Hutchins, Gregory M [Mountain View, CA

    2008-09-30

    The present invention provides a software system, PointRight, that allows for smooth and effortless control of pointing and input devices among multiple displays. With PointRight, a single free-floating mouse and keyboard can be used to control multiple screens. When the cursor reaches the edge of a screen it seamlessly moves to the adjacent screen and keyboard control is simultaneously redirected to the appropriate machine. Laptops may also redirect their keyboard and pointing device, and multiple pointers are supported simultaneously. The system automatically reconfigures itself as displays go on, go off, or change the machine they display.

  8. Innovations: clinical computing: an audio computer-assisted self-interviewing system for research and screening in public mental health settings.

    PubMed

    Bertollo, David N; Alexander, Mary Jane; Shinn, Marybeth; Aybar, Jalila B

    2007-06-01

    This column describes the nonproprietary software Talker, used to adapt screening instruments to audio computer-assisted self-interviewing (ACASI) systems for low-literacy populations and other populations. Talker supports ease of programming, multiple languages, on-site scoring, and the ability to update a central research database. Key features include highly readable text display, audio presentation of questions and audio prompting of answers, and optional touch screen input. The scripting language for adapting instruments is briefly described as well as two studies in which respondents provided positive feedback on its use.

  9. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    NASA Astrophysics Data System (ADS)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  10. Hepatitis B maternal screening, infant vaccination, and infant prophylaxis practices in North Carolina.

    PubMed

    Pierce, R L; Smith, S; Rowe-West, B; Sterritt, B

    1999-06-01

    To determine if the Advisory Committee on Immunization Practices hepatitis B screening, vaccination, and prophylaxis recommendations were being followed in North Carolina, and to establish a baseline hepatitis B seroprevalence rate. A survey of mother and infant birthing facility medical records. Four birthing facilities selected from each of the 7 districts in North Carolina (a total of 28 facilities). A probability proportional to size survey design was used to select 4763 mother-infant record pairs. All records came from the 1996 birth cohort. Maternal hepatitis B screening status, infant vaccination status, infants prophylaxis status, hepatitis B seroprevalence rate, demographic and clinical predictors for maternal infection, failure to receive prenatal care or for whom status was unknown, failure to screen, and failure to vaccinate. Ninety-two percent of pregnant women were screened for hepatitis B surface antigen. Eighty-six percent of infants received dose 1 of the hepatitis B vaccine. Four of the 9 infants with mothers who were hepatitis B surface antigen-positive did not receive both vaccine and hepatitis B immune globulin. The hepatitis B seroprevalence rate was 0.2%. Mothers who were not screened for infection were 3.4 times more likely to have infants who were not vaccinated. White mothers were twice as likely not to have their child vaccinated as mothers of other races. Not all infants with hepatitis B-infected mothers were receiving vaccine and hepatitis B immune globulin as recommended. Seroprevalence of hepatitis B infection may be lower in North Carolina than in other states. Hepatitis B laboratory test results should be included in every mother's medical record.

  11. Measuring Resident Physicians' Performance of Preventive Care

    PubMed Central

    Palonen, Katri P; Allison, Jeroan J; Heudebert, Gustavo R; Willett, Lisa L; Kiefe, Catarina I; Wall, Terry C; Houston, Thomas K

    2006-01-01

    BACKGROUND The Accreditation Council for Graduate Medical Education has suggested various methods for evaluation of practice-based learning and improvement competency, but data on implementation of these methods are limited. OBJECTIVE To compare medical record review and patient surveys on evaluating physician performance in preventive services in an outpatient resident clinic. DESIGN Within an ongoing quality improvement project, we collected baseline performance data on preventive services provided for patients at the University of Alabama at Birmingham (UAB) Internal Medicine Residents' ambulatory clinic. PARTICIPANTS Seventy internal medicine and medicine-pediatrics residents from the UAB Internal Medicine Residency program. MEASUREMENTS Resident- and clinic-level comparisons of aggregated patient survey and chart documentation rates of (1) screening for smoking status, (2) advising smokers to quit, (3) cholesterol screening, (4) mammography screening, and (5) pneumonia vaccination. RESULTS Six hundred and fifty-nine patient surveys and 761 charts were abstracted. At the clinic level, rates for screening of smoking status, recommending mammogram, and for cholesterol screening were similar (difference <5%) between the 2 methods. Higher rates for pneumonia vaccination (76% vs 67%) and advice to quit smoking (66% vs 52%) were seen on medical record review versus patient surveys. However, within-resident (N=70) comparison of 2 methods of estimating screening rates contained significant variability. The cost of medical record review was substantially higher ($107 vs $17/physician). CONCLUSIONS Medical record review and patient surveys provided similar rates for selected preventive health measures at the clinic level, with the exception of pneumonia vaccination and advising to quit smoking. A large variation among individual resident providers was noted. PMID:16499544

  12. Real time 3D structural and Doppler OCT imaging on graphics processing units

    NASA Astrophysics Data System (ADS)

    Sylwestrzak, Marcin; Szlag, Daniel; Szkulmowski, Maciej; Gorczyńska, Iwona; Bukowska, Danuta; Wojtkowski, Maciej; Targowski, Piotr

    2013-03-01

    In this report the application of graphics processing unit (GPU) programming for real-time 3D Fourier domain Optical Coherence Tomography (FdOCT) imaging with implementation of Doppler algorithms for visualization of the flows in capillary vessels is presented. Generally, the time of the data processing of the FdOCT data on the main processor of the computer (CPU) constitute a main limitation for real-time imaging. Employing additional algorithms, such as Doppler OCT analysis, makes this processing even more time consuming. Lately developed GPUs, which offers a very high computational power, give a solution to this problem. Taking advantages of them for massively parallel data processing, allow for real-time imaging in FdOCT. The presented software for structural and Doppler OCT allow for the whole processing with visualization of 2D data consisting of 2000 A-scans generated from 2048 pixels spectra with frame rate about 120 fps. The 3D imaging in the same mode of the volume data build of 220 × 100 A-scans is performed at a rate of about 8 frames per second. In this paper a software architecture, organization of the threads and optimization applied is shown. For illustration the screen shots recorded during real time imaging of the phantom (homogeneous water solution of Intralipid in glass capillary) and the human eye in-vivo is presented.

  13. Software Update.

    ERIC Educational Resources Information Center

    Currents, 2000

    2000-01-01

    A chart of 40 alumni-development database systems provides information on vendor/Web site, address, contact/phone, software name, price range, minimum suggested workstation/suggested server, standard reports/reporting tools, minimum/maximum record capacity, and number of installed sites/client type. (DB)

  14. SEER*Stat Software

    Cancer.gov

    If you have access to SEER Research Data, use SEER*Stat to analyze SEER and other cancer-related databases. View individual records and produce statistics including incidence, mortality, survival, prevalence, and multiple primary. Tutorials and related analytic software tools are available.

  15. Identification of Patient Safety Risks Associated with Electronic Health Records: A Software Quality Perspective.

    PubMed

    Virginio, Luiz A; Ricarte, Ivan Luiz Marques

    2015-01-01

    Although Electronic Health Records (EHR) can offer benefits to the health care process, there is a growing body of evidence that these systems can also incur risks to patient safety when developed or used improperly. This work is a literature review to identify these risks from a software quality perspective. Therefore, the risks were classified based on the ISO/IEC 25010 software quality model. The risks identified were related mainly to the characteristics of "functional suitability" (i.e., software bugs) and "usability" (i.e., interface prone to user error). This work elucidates the fact that EHR quality problems can adversely affect patient safety, resulting in errors such as incorrect patient identification, incorrect calculation of medication dosages, and lack of access to patient data. Therefore, the risks presented here provide the basis for developers and EHR regulating bodies to pay attention to the quality aspects of these systems that can result in patient harm.

  16. Performance of automated and manual coding systems for occupational data: a case study of historical records.

    PubMed

    Patel, Mehul D; Rose, Kathryn M; Owens, Cindy R; Bang, Heejung; Kaufman, Jay S

    2012-03-01

    Occupational data are a common source of workplace exposure and socioeconomic information in epidemiologic research. We compared the performance of two occupation coding methods, an automated software and a manual coder, using occupation and industry titles from U.S. historical records. We collected parental occupational data from 1920-40s birth certificates, Census records, and city directories on 3,135 deceased individuals in the Atherosclerosis Risk in Communities (ARIC) study. Unique occupation-industry narratives were assigned codes by a manual coder and the Standardized Occupation and Industry Coding software program. We calculated agreement between coding methods of classification into major Census occupational groups. Automated coding software assigned codes to 71% of occupations and 76% of industries. Of this subset coded by software, 73% of occupation codes and 69% of industry codes matched between automated and manual coding. For major occupational groups, agreement improved to 89% (kappa = 0.86). Automated occupational coding is a cost-efficient alternative to manual coding. However, some manual coding is required to code incomplete information. We found substantial variability between coders in the assignment of occupations although not as large for major groups.

  17. Analysis of clinical decision support system malfunctions: a case series and survey.

    PubMed

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-11-01

    To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. We identified and investigated several CDSS malfunctions at Brigham and Women's Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. We identified four CDSS malfunctions at Brigham and Women's Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  18. Real-time classification of signals from three-component seismic sensors using neural nets

    NASA Astrophysics Data System (ADS)

    Bowman, B. C.; Dowla, F.

    1992-05-01

    Adaptive seismic data acquisition systems with capabilities of signal discrimination and event classification are important in treaty monitoring, proliferation, and earthquake early detection systems. Potential applications include monitoring underground chemical explosions, as well as other military, cultural, and natural activities where characteristics of signals change rapidly and without warning. In these applications, the ability to detect and interpret events rapidly without falling behind the influx of the data is critical. We developed a system for real-time data acquisition, analysis, learning, and classification of recorded events employing some of the latest technology in computer hardware, software, and artificial neural networks methods. The system is able to train dynamically, and updates its knowledge based on new data. The software is modular and hardware-independent; i.e., the front-end instrumentation is transparent to the analysis system. The software is designed to take advantage of the multiprocessing environment of the Unix operating system. The Unix System V shared memory and static RAM protocols for data access and the semaphore mechanism for interprocess communications were used. As the three-component sensor detects a seismic signal, it is displayed graphically on a color monitor using X11/Xlib graphics with interactive screening capabilities. For interesting events, the triaxial signal polarization is computed, a fast Fourier Transform (FFT) algorithm is applied, and the normalized power spectrum is transmitted to a backpropagation neural network for event classification. The system is currently capable of handling three data channels with a sampling rate of 500 Hz, which covers the bandwidth of most seismic events. The system has been tested in laboratory setting with artificial events generated in the vicinity of a three-component sensor.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheu, R; Ghafar, R; Powers, A

    Purpose: Demonstrate the effectiveness of in-house software in ensuring EMR workflow efficiency and safety. Methods: A web-based dashboard system (WBDS) was developed to monitor clinical workflow in real time using web technology (WAMP) through ODBC (Open Database Connectivity). Within Mosaiq (Elekta Inc), operational workflow is driven and indicated by Quality Check Lists (QCLs), which is triggered by automation software IQ Scripts (Elekta Inc); QCLs rely on user completion to propagate. The WBDS retrieves data directly from the Mosaig SQL database and tracks clinical events in real time. For example, the necessity of a physics initial chart check can be determinedmore » by screening all patients on treatment who have received their first fraction and who have not yet had their first chart check. Monitoring similar “real” events with our in-house software creates a safety net as its propagation does not rely on individual users input. Results: The WBDS monitors the following: patient care workflow (initial consult to end of treatment), daily treatment consistency (scheduling, technique, charges), physics chart checks (initial, EOT, weekly), new starts, missing treatments (>3 warning/>5 fractions, action required), and machine overrides. The WBDS can be launched from any web browser which allows the end user complete transparency and timely information. Since the creation of the dashboards, workflow interruptions due to accidental deletion or completion of QCLs were eliminated. Additionally, all physics chart checks were completed timely. Prompt notifications of treatment record inconsistency and machine overrides have decreased the amount of time between occurrence and execution of corrective action. Conclusion: Our clinical workflow relies primarily on QCLs and IQ Scripts; however, this functionality is not the panacea of safety and efficiency. The WBDS creates a more thorough system of checks to provide a safer and near error-less working environment.« less

  20. Automated quality checks on repeat prescribing.

    PubMed Central

    Rogers, Jeremy E; Wroe, Christopher J; Roberts, Angus; Swallow, Angela; Stables, David; Cantrill, Judith A; Rector, Alan L

    2003-01-01

    BACKGROUND: Good clinical practice in primary care includes periodic review of repeat prescriptions. Markers of prescriptions that may need review have been described, but manually checking all repeat prescriptions against the markers would be impractical. AIM: To investigate the feasibility of computerising the application of repeat prescribing quality checks to electronic patient records in United Kingdom (UK) primary care. DESIGN OF STUDY: Software performance test against benchmark manual analysis of cross-sectional convenience sample of prescribing documentation. SETTING: Three general practices in Greater Manchester, in the north west of England, during a 4-month period in 2001. METHOD: A machine-readable drug information resource, based on the British National Formulary (BNF) as the 'gold standard' for valid drug indications, was installed in three practices. Software raised alerts for each repeat prescribed item where the electronic patient record contained no valid indication for the medication. Alerts raised by the software in two practices were analysed manually. Clinical reaction to the software was assessed by semi-structured interviews in three practices. RESULTS: There was no valid indication in the electronic medical records for 14.8% of repeat prescribed items. Sixty-two per cent of all alerts generated were incorrect. Forty-three per cent of all incorrect alerts were as a result of errors in the drug information resource, 44% to locally idiosyncratic clinical coding, 8% to the use of the BNF without adaptation as a gold standard, and 5% to the inability of the system to infer diagnoses that, although unrecorded, would be 'obvious' to a clinical reading the record. The interviewed clinicians supported the goals of the software. CONCLUSION: Using electronic records for secondary decision support purposes will benefit from (and may require) both more consistent electronic clinical data collection across multiple sites, and reconciling clinicians' willingness to infer unstated but 'obvious' diagnoses with the machine's inability to do the same. PMID:14702902

  1. Designing an algorithm to preserve privacy for medical record linkage with error-prone data.

    PubMed

    Pal, Doyel; Chen, Tingting; Zhong, Sheng; Khethavath, Praveen

    2014-01-20

    Linking medical records across different medical service providers is important to the enhancement of health care quality and public health surveillance. In records linkage, protecting the patients' privacy is a primary requirement. In real-world health care databases, records may well contain errors due to various reasons such as typos. Linking the error-prone data and preserving data privacy at the same time are very difficult. Existing privacy preserving solutions for this problem are only restricted to textual data. To enable different medical service providers to link their error-prone data in a private way, our aim was to provide a holistic solution by designing and developing a medical record linkage system for medical service providers. To initiate a record linkage, one provider selects one of its collaborators in the Connection Management Module, chooses some attributes of the database to be matched, and establishes the connection with the collaborator after the negotiation. In the Data Matching Module, for error-free data, our solution offered two different choices for cryptographic schemes. For error-prone numerical data, we proposed a newly designed privacy preserving linking algorithm named the Error-Tolerant Linking Algorithm, that allows the error-prone data to be correctly matched if the distance between the two records is below a threshold. We designed and developed a comprehensive and user-friendly software system that provides privacy preserving record linkage functions for medical service providers, which meets the regulation of Health Insurance Portability and Accountability Act. It does not require a third party and it is secure in that neither entity can learn the records in the other's database. Moreover, our novel Error-Tolerant Linking Algorithm implemented in this software can work well with error-prone numerical data. We theoretically proved the correctness and security of our Error-Tolerant Linking Algorithm. We have also fully implemented the software. The experimental results showed that it is reliable and efficient. The design of our software is open so that the existing textual matching methods can be easily integrated into the system. Designing algorithms to enable medical records linkage for error-prone numerical data and protect data privacy at the same time is difficult. Our proposed solution does not need a trusted third party and is secure in that in the linking process, neither entity can learn the records in the other's database.

  2. Australian immunisation registers: established foundations and opportunities for improvement.

    PubMed

    Chin, L K; Crawford, N W; Rowles, G; Buttery, J P

    2012-04-19

    The National Immunisation Program Schedule in Australia is formulated and funded nationally under the population-wide Medicare system. The policy is implemented by the eight state and territory jurisdictions. The national immunisation registers consist of the Australian Childhood Immunisation Register (ACIR), and, more recently, the National Human Papillomavirus (HPV) Vaccination Program Register. Moreover, a variety of jurisdiction-based registers and primary care practice software systems exist, which interact with the national registers. General practitioners can obtain reports listing patients under seven years attending their practice and recorded as 'not fully immunised', and immunisation coverage rates for their practice linked to government incentives through Medicare. A 2011 report documents national coverage of 91.8% fully immunised at 12 months, and 92.6% at 24 months. The HPV register provides information on vaccination coverage with the potential to link with a register of cervical cancer screening results. Limitations of current national register include inability to easily access immunisation histories beyond seven years of age, and issues of underreporting and timeliness, which impact significantly the immunisation coverage estimates. The linkage of these registers with healthcare outcome data will further enhance public health outcomes by enabling rapid, population-level vaccine safety and effectiveness investigations in a nation with a track record as an 'early adopter' of new childhood vaccines.

  3. Cardiac registers: the adult cardiac surgery register.

    PubMed

    Bridgewater, Ben

    2010-09-01

    AIMS OF THE SCTS ADULT CARDIAC SURGERY DATABASE: To measure the quality of care of adult cardiac surgery in GB and Ireland and provide information for quality improvement and research. Feedback of structured data to hospitals, publication of named hospital and surgeon mortality data, publication of benchmarked activity and risk adjusted clinical outcomes through intermittent comprehensive database reports, annual screening of all hospital and individual surgeon risk adjusted mortality rates by the professional society. All NHS hospitals in England, Scotland and Wales with input from some private providers and hospitals in Ireland. 1994-ongoing. Consecutive patients, unconsented. Current number of records: 400000. Adult cardiac surgery operations excluding cardiac transplantation and ventricular assist devices. 129 fields covering demographic factors, pre-operative risk factors, operative details and post-operative in-hospital outcomes. Entry onto local software systems by direct key board entry or subsequent transcription from paper records, with subsequent electronic upload to the central cardiac audit database. Non-financial incentives at hospital level. Local validation processes exist in the hospitals. There is currently no external data validation process. All cause mortality is obtained through linkage with Office for National Statistics. No other linkages exist at present. Available for research and audit by application to the SCTS database committee at http://www.scts.org.

  4. Craniux: A LabVIEW-Based Modular Software Framework for Brain-Machine Interface Research

    DTIC Science & Technology

    2011-01-01

    open-source BMI software solu- tions are currently available, we feel that the Craniux software package fills a specific need in the realm of BMI...data, such as cortical source imaging using EEG or MEG recordings. It is with these characteristics in mind that we feel the Craniux software package...S. Adee, “Dean Kamen’s ‘luke arm’ prosthesis readies for clinical trials,” IEEE Spectrum, February 2008, http://spectrum .ieee.org/biomedical

  5. Software-recorded and self-reported duration of computer use in relation to the onset of severe arm-wrist-hand pain and neck-shoulder pain.

    PubMed

    Ijmker, Stefan; Huysmans, Maaike A; van der Beek, Allard J; Knol, Dirk L; van Mechelen, Willem; Bongers, Paulien M; Blatter, Birgitte M

    2011-07-01

    In both science and media, the adverse effects of a long duration of computer use at work on musculoskeletal health have long been debated. Until recently, the duration of computer use was mainly measured by self-reports, and studies using more objective measures, such as software-recorded computer duration, were lacking. The objective of this study was to examine the association between duration of computer use at work, measured with software and self-reports, and the onset of severe arm-wrist-hand and neck-shoulder symptoms. A 2-year follow-up study was conducted between 2004 and 2006 among 1951 office workers in The Netherlands. Self-reported computer duration and other risk factors were collected at baseline and at 1-year follow-up. Computer use at work was recorded continuously with computer software for 1009 participants. Outcome questionnaires were obtained at baseline and every 3 months during follow-up. Cases were identified based on the transition within 3 months of no or minor symptoms to severe symptoms. Self-reported duration of computer use was positively associated with the onset of both arm-wrist-hand (RR 1.9, 95% CI 1.1 to 3.1 for more than 4 h/day of total computer use at work) and neck-shoulder symptoms (RR 1.5, 95% CI 1.1 to 2.0 for more than 4 h/day of mouse use at work). The recorded duration of computer use did not show any statistically significant association with the outcomes. In the present study, no association was found between the software-recorded duration of computer use at work and the onset of severe arm-wrist-hand and neck-shoulder symptoms using an exposure window of 3 months. In contrast, a positive association was found between the self-reported duration of computer use at work and the onset of severe arm-wrist-hand and neck-shoulder symptoms. The different findings for recorded and self-reported computer duration could not be explained satisfactorily.

  6. Anthrax outbreaks in the humans - livestock and wildlife interface areas of Northern Tanzania: a retrospective record review 2006-2016.

    PubMed

    Mwakapeje, Elibariki Reuben; Høgset, Sol; Fyumagwa, Robert; Nonga, Hezron Emmanuel; Mdegela, Robinson Hammerthon; Skjerve, Eystein

    2018-01-05

    Anthrax outbreaks in Tanzania have been reported from the human, livestock and wildlife sectors over several years, and is among the notifiable diseases. Despite frequent anthrax outbreaks, there is no comprehensive dataset indicating the magnitude and distribution of the disease in susceptible species. This study is a retrospective review of anthrax outbreaks from the human, livestock, and wildlife surveillance systems from 2006 to 2016. The objectives were to identify hotspot districts, describe anthrax epidemiology in the hotspot areas, evaluate the efficiency of the anthrax response systems and identify potential areas for further observational studies. We prepared a spreadsheet template for a retrospective comprehensive record review at different surveillance levels in Tanzania. We captured data elements including demographic characteristics of different species, the name of health facility, and date of anthrax diagnosis. Also, we collected data on the date of specimen collection, species screened, type of laboratory test, laboratory results and the outcome recorded at the end of treatment in humans. After establishing the database, we produced maps in Quantum GIS software and transferred cleaned data to Stata software for supportive statistical analysis. Anthrax reported incidences over 4 years in humans were much higher in the Arusha region (7.88/100,000) followed by Kilimanjaro region (6.64/100,000) than other regions of Tanzania Mainland. The health facility based review from hotspot districts in parts of Arusha and Kilimanjaro regions from 2006 to 2016, identified 330 human anthrax cases from the selected health facilities in the two regions. Out of 161 livestock and 57 wildlife specimen tested, 103 and 18 respectively, were positive for anthrax. This study revealed that there is gross under-reporting in the existing surveillance systems which is an obstacle for estimating a true burden of anthrax in the hotspot districts. Repeated occurrences of anthrax in livestock, wildlife and humans in the same locations at the same time calls for the need to strengthen links and promote inter-disciplinary and multi-sectoral collaboration to enhance prevention and control measures under a One Health approach.

  7. Novel KCNQ2 channel activators discovered using fluorescence-based and automated patch-clamp-based high-throughput screening techniques

    PubMed Central

    Yue, Jin-feng; Qiao, Guan-hua; Liu, Ni; Nan, Fa-jun; Gao, Zhao-bing

    2016-01-01

    Aim: To establish an improved, high-throughput screening techniques for identifying novel KCNQ2 channel activators. Methods: KCNQ2 channels were stably expressed in CHO cells (KCNQ2 cells). Thallium flux assay was used for primary screening, and 384-well automated patch-clamp IonWorks Barracuda was used for hit validation. Two validated activators were characterized using a conventional patch-clamp recording technique. Results: From a collection of 80 000 compounds, the primary screening revealed a total of 565 compounds that potentiated the fluorescence signals in thallium flux assay by more than 150%. When the 565 hits were examined in IonWorks Barracuda, 38 compounds significantly enhanced the outward currents recorded in KCNQ2 cells, and were confirmed as KCNQ2 activators. In the conventional patch-clamp recordings, two validated activators ZG1732 and ZG2083 enhanced KCNQ2 currents with EC50 values of 1.04±0.18 μmol/L and 1.37±0.06 μmol/L, respectively. Conclusion: The combination of thallium flux assay and IonWorks Barracuda assay is an efficient high-throughput screening (HTS) route for discovering KCNQ2 activators. PMID:26725738

  8. Discrete Element Modeling (DEM) of Triboelectrically Charged Particles: Revised Experiments

    NASA Technical Reports Server (NTRS)

    Hogue, Michael D.; Calle, Carlos I.; Curry, D. R.; Weitzman, P. S.

    2008-01-01

    In a previous work, the addition of basic screened Coulombic electrostatic forces to an existing commercial discrete element modeling (DEM) software was reported. Triboelectric experiments were performed to charge glass spheres rolling on inclined planes of various materials. Charge generation constants and the Q/m ratios for the test materials were calculated from the experimental data and compared to the simulation output of the DEM software. In this paper, we will discuss new values of the charge generation constants calculated from improved experimental procedures and data. Also, planned work to include dielectrophoretic, Van der Waals forces, and advanced mechanical forces into the software will be discussed.

  9. Low-cost data analysis systems for processing multispectral scanner data

    NASA Technical Reports Server (NTRS)

    Whitely, S. L.

    1976-01-01

    The basic hardware and software requirements are described for four low cost analysis systems for computer generated land use maps. The data analysis systems consist of an image display system, a small digital computer, and an output recording device. Software is described together with some of the display and recording devices, and typical costs are cited. Computer requirements are given, and two approaches are described for converting black-white film and electrostatic printer output to inexpensive color output products. Examples of output products are shown.

  10. Using Digital Acoustic Recording Tags to Detect Marine Mammals on Navy Ranges and Study their Responses to Naval Sonar

    DTIC Science & Technology

    2011-02-01

    written in C and assembly languages. 2) executable code for the low-power wakeup controller in the tag. This software is responsible for the VHF...used in the tag software. The multi-rate processing in the new tag necessitated a more complex task- scheduling software architecture. The effort of

  11. Endoscopic Stone Measurement During Ureteroscopy.

    PubMed

    Ludwig, Wesley W; Lim, Sunghwan; Stoianovici, Dan; Matlaga, Brian R

    2018-01-01

    Currently, stone size cannot be accurately measured while performing flexible ureteroscopy (URS). We developed novel software for ureteroscopic, stone size measurement, and then evaluated its performance. A novel application capable of measuring stone fragment size, based on the known distance of the basket tip in the ureteroscope's visual field, was designed and calibrated in a laboratory setting. Complete URS procedures were recorded and 30 stone fragments were extracted and measured using digital calipers. The novel software program was applied to the recorded URS footage to obtain ureteroscope-derived stone size measurements. These ureteroscope-derived measurements were then compared with the actual-measured fragment size. The median longitudinal and transversal errors were 0.14 mm (95% confidence interval [CI] 0.1, 0.18) and 0.09 mm (95% CI 0.02, 0.15), respectively. The overall software accuracy and precision were 0.17 and 0.15 mm, respectively. The longitudinal and transversal measurements obtained by the software and digital calipers were highly correlated (r = 0.97 and 0.93). Neither stone size nor stone type was correlated with error measurements. This novel method and software reliably measured stone fragment size during URS. The software ultimately has the potential to make URS safer and more efficient.

  12. Descriptions of Free and Freeware Software in the Mathematics Teaching

    NASA Astrophysics Data System (ADS)

    Antunes de Macedo, Josue; Neves de Almeida, Samara; Voelzke, Marcos Rincon

    2016-05-01

    This paper presents the analysis and the cataloging of free and freeware mathematical software available on the internet, a brief explanation of them, and types of licenses for use in teaching and learning. The methodology is based on the qualitative research. Among the different types of software found, it stands out in algebra, the Winmat, that works with linear algebra, matrices and linear systems. In geometry, the GeoGebra, which can be used in the study of functions, plan and spatial geometry, algebra and calculus. For graphing, can quote the Graph and Graphequation. With Graphmatica software, it is possible to build various graphs of mathematical equations on the same screen, representing cartesian equations, inequalities, parametric among other functions. The Winplot allows the user to build graphics in two and three dimensions functions and mathematical equations. Thus, this work aims to present the teachers some free math software able to be used in the classroom.

  13. gr-MRI: A software package for magnetic resonance imaging using software defined radios.

    PubMed

    Hasselwander, Christopher J; Cao, Zhipeng; Grissom, William A

    2016-09-01

    The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately $2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs. Copyright © 2016. Published by Elsevier Inc.

  14. Wearable Notification via Dissemination Service in a Pervasive Computing Environment

    DTIC Science & Technology

    2015-09-01

    context, state, and environment in a manner that would be transparent to a Soldier’s common operations. 15. SUBJECT TERMS pervasive computing, Android ...of user context shifts, i.e., changes in the user’s position, history , workflow, or resource interests. If the PCE is described as a 2-component...convenient viewing on the Glass’s screen just above the line of sight. All of the software developed uses Google’s Android open-source software stack

  15. Workflow in interventional radiology: uterine fibroid embolization (UFE)

    NASA Astrophysics Data System (ADS)

    Lindisch, David; Neumuth, Thomas; Burgert, Oliver; Spies, James; Cleary, Kevin

    2008-03-01

    Workflow analysis can be used to record the steps taken during clinical interventions with the goal of identifying bottlenecks and streamlining the procedure efficiency. In this study, we recorded the workflow for uterine fibroid embolization (UFE) procedures in the interventional radiology suite at Georgetown University Hospital in Washington, DC, USA. We employed a custom client/server software architecture developed by the Innovation Center for Computer Assisted Surgery (ICCAS) at the University of Leipzig, Germany. This software runs in a JAVA environment and enables an observer to record the actions taken by the physician and surgical team during these interventions. The data recorded is stored as an XML document, which can then be further processed. We recorded data from 30 patients and found a mean intervention time of 01:49:46 (+/- 16:04) minutes. The critical intervention step, the embolization, had a mean time of 00:15:42 (+/- 05:49) minutes, which was only 15% of the total intervention time.

  16. Computer Reconstruction of Spirit Predicament

    NASA Image and Video Library

    2009-11-04

    A screen shot from software used by the Mars Exploration Rover team for assessing movements by Spirit and Opportunity illustrates the degree to which Spirit wheels have become embedded in soft material at the location called Troy.

  17. Network Solutions.

    ERIC Educational Resources Information Center

    Vietzke, Robert; And Others

    1996-01-01

    This special section explains the latest developments in networking technologies, profiles school districts benefiting from successful implementations, and reviews new products for building networks. Highlights include ATM (asynchronous transfer mode), cable modems, networking switches, Internet screening software, file servers, network management…

  18. Pack-Year Cigarette Smoking History for Determination of Lung Cancer Screening Eligibility. Comparison of the Electronic Medical Record versus a Shared Decision-making Conversation.

    PubMed

    Modin, Hannah E; Fathi, Joelle T; Gilbert, Christopher R; Wilshire, Candice L; Wilson, Andrew K; Aye, Ralph W; Farivar, Alexander S; Louie, Brian E; Vallières, Eric; Gorden, Jed A

    2017-08-01

    Implementation of lung cancer screening programs is occurring across the United States. Programs vary in approaches to patient identification and shared decision-making. The eligibility of persons referred to screening programs, the outcomes of eligibility determination during shared decision-making, and the potential for the electronic medical record (EMR) to identify eligible individuals have not been well described. Our objectives were to assess the eligibility of individuals referred for lung cancer screening and compare information extracted from the EMR to information derived from a shared decision-making conversation for the determination of eligibility for lung cancer screening. We performed a retrospective analysis of individuals referred to a centralized lung cancer screening program serving a five-hospital health services system in Seattle, Washington between October 2014 and January 2016. Demographics, referral, and outcomes data were collected. A pack-year smoking history derived from the EMR was compared with the pack-year history obtained during a shared decision-making conversation performed by a licensed nurse professional representing the lung cancer screening program. A total of 423 individuals were referred to the program, of whom 59.6% (252 of 423) were eligible. Of those, 88.9% (224 of 252) elected screening. There was 96.2% (230 of 239) discordance in pack-year smoking history between the EMR and the shared decision-making conversation. The EMR underreported pack-years of smoking for 85.2% (196 of 230) of the participants, with a median difference of 29.2 pack-years. If identification of eligible individuals relied solely on the accuracy of the pack-year smoking history recorded in the EMR, 53.6% (128 of 239) would have failed to meet the 30-pack-year threshold for screening. Many individuals referred for lung cancer screening may be ineligible. Overreliance on the EMR for identification of individuals at risk may lead to missed opportunities for appropriate lung cancer screening.

  19. [Screening for malnutrition among hospitalized patients in a Colombian University Hospital].

    PubMed

    Cruz, Viviana; Bernal, Laura; Buitrago, Giancarlo; Ruiz, Álvaro J

    2017-04-01

    On admission, 30 to 50% of hospitalized patients have some degree of malnutrition, which is associated with longer length of stay, higher rates of complications, mortality and greater costs. To determine the frequency of screening for risk of malnutrition in medical records and assess the usefulness of the Malnutrition Screening Tool (MST). In a cross-sectional study, we searched for malnutrition screening in medical records, and we applied the MST tool to hospitalized patients at the Internal Medicine Wards of San Ignacio University Hospital. Of 295 patients included, none had been screened for malnutrition since hospital admission. Sixty one percent were at nutritional risk, with a higher prevalence among patients with HIV (85.7%), cancer (77.5%) and pneumonia. A positive MST result was associated with a 3.2 days increase in length of hospital stay (p = 0.024). The prevalence of malnutrition risk in hospitalized patients is high, but its screening is inadequate and it is underdiagnosed. The MST tool is simple, fast, low-cost, and has a good diagnostic performance.

  20. Design of a projection display screen with vanishing color shift for rear-projection HDTV

    NASA Astrophysics Data System (ADS)

    Liu, Xiu; Zhu, Jin-lin

    1996-09-01

    Using bi-convex cylinder lens with matrix structure, the transmissive projection display screen with high contrast and wider viewing angle has been widely used in large rear projection TV and video projectors, it obtained a inhere color shift and puzzled the designer of display screen for RGB projection tube in-line adjustment. Based on the method of light beam racing, the general software of designing projection display screen has been developed and the computer model of vanishing color shift for rear projection HDTV has bee completed. This paper discussed the practical designing method to vanish the defect of color shift and mentioned the relations between the primary optical parameters of display screen and relative geometry sizes of lens' surface. The distributions of optical gain to viewing angle and the influences on engineering design are briefly analyzed.

  1. Use of a geographic information system (GIS) for targeting radon screening programs in South Dakota

    PubMed Central

    Kearfott, Kimberlee J.; Whetstone, Zachary D.; Rafique Mir, Khwaja M.

    2016-01-01

    Because 222Rn is a progeny of 238U, the relative abundance of uranium may be used to predict the areas that have the potential for high indoor radon concentration and therefore determine the best areas to conduct future surveys. Geographic Information System (GIS) mapping software was used to construct maps of South Dakota that included levels of uranium concentrations in soil and stream water and uranium deposits. Maps of existing populations and the types of land were also generated. Existing data about average indoor radon levels by county taken from a databank were included for consideration. Although the soil and stream data and existing recorded average indoor radon levels were sparse, it was determined that the most likely locations of elevated indoor radon would be in the northwest and southwest corners of the state. Indoor radon levels were only available for 9 out of 66 counties in South Dakota. This sparcity of data precluded a study of correlation of radon to geological features, but further motivates the need for more testing in the state. Only actual measurements should be used to determine levels of indoor radon because of the strong roles home construction and localized geology play in radon concentration. However, the data visualization method demonstrated here is potentially useful for directing resources relating to radon screening campaigns. PMID:26472478

  2. GeoBoost: accelerating research involving the geospatial metadata of virus GenBank records.

    PubMed

    Tahsin, Tasnia; Weissenbacher, Davy; O'Connor, Karen; Magge, Arjun; Scotch, Matthew; Gonzalez-Hernandez, Graciela

    2018-05-01

    GeoBoost is a command-line software package developed to address sparse or incomplete metadata in GenBank sequence records that relate to the location of the infected host (LOIH) of viruses. Given a set of GenBank accession numbers corresponding to virus GenBank records, GeoBoost extracts, integrates and normalizes geographic information reflecting the LOIH of the viruses using integrated information from GenBank metadata and related full-text publications. In addition, to facilitate probabilistic geospatial modeling, GeoBoost assigns probability scores for each possible LOIH. Binaries and resources required for running GeoBoost are packed into a single zipped file and freely available for download at https://tinyurl.com/geoboost. A video tutorial is included to help users quickly and easily install and run the software. The software is implemented in Java 1.8, and supported on MS Windows and Linux platforms. gragon@upenn.edu. Supplementary data are available at Bioinformatics online.

  3. Workflow in interventional radiology: nerve blocks and facet blocks

    NASA Astrophysics Data System (ADS)

    Siddoway, Donald; Ingeholm, Mary Lou; Burgert, Oliver; Neumuth, Thomas; Watson, Vance; Cleary, Kevin

    2006-03-01

    Workflow analysis has the potential to dramatically improve the efficiency and clinical outcomes of medical procedures. In this study, we recorded the workflow for nerve block and facet block procedures in the interventional radiology suite at Georgetown University Hospital in Washington, DC, USA. We employed a custom client/server software architecture developed by the Innovation Center for Computer Assisted Surgery (ICCAS) at the University of Leipzig, Germany. This software runs in an internet browser, and allows the user to record the actions taken by the physician during a procedure. The data recorded during the procedure is stored as an XML document, which can then be further processed. We have successfully gathered data on a number if cases using a tablet PC, and these preliminary results show the feasibility of using this software in an interventional radiology setting. We are currently accruing additional cases and when more data has been collected we will analyze the workflow of these procedures to look for inefficiencies and potential improvements.

  4. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    NASA Astrophysics Data System (ADS)

    Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti

    2015-04-01

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  5. The benefits of hydrotherapy to patients with spinal cord injuries.

    PubMed

    Ellapen, Terry J; Hammill, Henriëtte V; Swanepoel, Mariëtte; Strydom, Gert L

    2018-01-01

    Many patients with spinal cord injury (PWSCI) lead sedentary lifestyles, experiencing poor quality of life and medical challenges. PWSCI don't like to participate in land-based-exercises because it's tedious to perform the same exercises, decreasing their rehabilitative compliance and negatively impacting their well-being. An alternative exercise environment and exercises may alleviate boredom, enhancing compliance. Discuss the benefits of hydrotherapy to PWSCI concerning underwater gait-kinematics, thermoregulatory and cardiovascular responses and spasticity. A literature surveillance was conducted between 1998 and 2017, through the Crossref meta-database and Google Scholar, according to the PRISMA procedures. Key search words were water-therapy, aquatic-therapy, hydrotherapy, spinal cord injury, rehabilitation, human, kinematics, underwater gait, cardiorespiratory, thermoregulation and spasticity. The quality of each paper was evaluated using a modified Downs and Black Appraisal Scale. The participants were records pertaining to PWSCI and hydrotherapy. The outcomes of interest were: hydrotherapy interventions, the impact of hydrotherapy on gait-kinematics, thermoregulation during water submersion and cardiorespiratory function of PWSCI. Omitted records included: non-English publications from before 1998 or unrelated to hydrotherapy and PWSCI. The record screening admissibility was performed as follows: the title screen, the abstract screen and the full text screen. Literature search identified 1080 records. Upon application of the exclusion criteria, 92 titles, 29 abstracts and 17 full text records were eligible. Only 15 records were selected to be included in this clinical commentary. Evidence shows a paucity of randomised control trials (RCT) conducted in this field. Hydrotherapy improves PWSCI underwater gait-kinematics, cardiorespiratory and thermoregulatory responses and reduces spasticity.

  6. The benefits of hydrotherapy to patients with spinal cord injuries

    PubMed Central

    Strydom, Gert L.

    2018-01-01

    Background Many patients with spinal cord injury (PWSCI) lead sedentary lifestyles, experiencing poor quality of life and medical challenges. PWSCI don’t like to participate in land-based-exercises because it’s tedious to perform the same exercises, decreasing their rehabilitative compliance and negatively impacting their well-being. An alternative exercise environment and exercises may alleviate boredom, enhancing compliance. Objectives Discuss the benefits of hydrotherapy to PWSCI concerning underwater gait-kinematics, thermoregulatory and cardiovascular responses and spasticity. Methodology A literature surveillance was conducted between 1998 and 2017, through the Crossref meta-database and Google Scholar, according to the PRISMA procedures. Key search words were water-therapy, aquatic-therapy, hydrotherapy, spinal cord injury, rehabilitation, human, kinematics, underwater gait, cardiorespiratory, thermoregulation and spasticity. The quality of each paper was evaluated using a modified Downs and Black Appraisal Scale. The participants were records pertaining to PWSCI and hydrotherapy. The outcomes of interest were: hydrotherapy interventions, the impact of hydrotherapy on gait-kinematics, thermoregulation during water submersion and cardiorespiratory function of PWSCI. Omitted records included: non-English publications from before 1998 or unrelated to hydrotherapy and PWSCI. The record screening admissibility was performed as follows: the title screen, the abstract screen and the full text screen. Results Literature search identified 1080 records. Upon application of the exclusion criteria, 92 titles, 29 abstracts and 17 full text records were eligible. Only 15 records were selected to be included in this clinical commentary. Evidence shows a paucity of randomised control trials (RCT) conducted in this field. Conclusion Hydrotherapy improves PWSCI underwater gait-kinematics, cardiorespiratory and thermoregulatory responses and reduces spasticity. PMID:29850439

  7. Antioxidant capacity of human saliva and periodontal screening assessment in healthy adults.

    PubMed

    Tartaglia, Gianluca Martino; Gagliano, Nicoletta; Zarbin, Luca; Tolomeo, Giorgia; Sforza, Chiarella

    2017-06-01

    Saliva plays a pivotal role as an antioxidant system, and saliva antioxidant levels are reduced in patients with periodontal disease. Recently, a biochemical test able to determine saliva antioxidant levels was proposed as predictive for oral cavity diseases, but it was not clinically tested. In this preliminary study, we evaluated the relationships between Periodontal Screening and Recordings characteristics of patients and saliva antioxidant levels measures. Thirty-nine patients (12 men, 27 women; mean age, 46 years, SD 17) attending the dental hygiene unit of a Private Clinic underwent a Periodontal Screening and Recordings examination and a saliva antioxidant levels measurement using a biochemical commercial test. The results of the clinical periodontal examination were compared to those obtained by the saliva test. Approximately 70% of patients showed a low saliva antioxidant levels value, while the other patients had Optimal/Normal values. Thirteen patients (33%) resulted positive to Periodontal Screening and Recordings test. Using Periodontal Screening and Recordings values as gold standard, the saliva antioxidant levels test correctly classified 52.6% of patients; sensitivity was 84.6%, specificity was 36%. The saliva antioxidant levels test had a good sensitivity when compared to the gold standard; this finding corroborates the hypothesis that alterations of the oral antioxidant levels are related to periodontal disease. The reduced specificity shows that saliva antioxidant levels test could detect alterations predisposing to periodontal disease before clinically evident aspects. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. NASA Records Database

    NASA Technical Reports Server (NTRS)

    Callac, Christopher; Lunsford, Michelle

    2005-01-01

    The NASA Records Database, comprising a Web-based application program and a database, is used to administer an archive of paper records at Stennis Space Center. The system begins with an electronic form, into which a user enters information about records that the user is sending to the archive. The form is smart : it provides instructions for entering information correctly and prompts the user to enter all required information. Once complete, the form is digitally signed and submitted to the database. The system determines which storage locations are not in use, assigns the user s boxes of records to some of them, and enters these assignments in the database. Thereafter, the software tracks the boxes and can be used to locate them. By use of search capabilities of the software, specific records can be sought by box storage locations, accession numbers, record dates, submitting organizations, or details of the records themselves. Boxes can be marked with such statuses as checked out, lost, transferred, and destroyed. The system can generate reports showing boxes awaiting destruction or transfer. When boxes are transferred to the National Archives and Records Administration (NARA), the system can automatically fill out NARA records-transfer forms. Currently, several other NASA Centers are considering deploying the NASA Records Database to help automate their records archives.

  9. Educational Video Recording and Editing for The Hand Surgeon

    PubMed Central

    Rehim, Shady A.; Chung, Kevin C.

    2016-01-01

    Digital video recordings are increasingly used across various medical and surgical disciplines including hand surgery for documentation of patient care, resident education, scientific presentations and publications. In recent years, the introduction of sophisticated computer hardware and software technology has simplified the process of digital video production and improved means of disseminating large digital data files. However, the creation of high quality surgical video footage requires basic understanding of key technical considerations, together with creativity and sound aesthetic judgment of the videographer. In this article we outline the practical steps involved with equipment preparation, video recording, editing and archiving as well as guidance for the choice of suitable hardware and software equipment. PMID:25911212

  10. [Software-based visualization of patient flow at a university eye clinic].

    PubMed

    Greb, O; Abou Moulig, W; Hufendiek, K; Junker, B; Framme, C

    2017-03-01

    This article presents a method for visualization and navigation of patient flow in outpatient eye clinics with a high level of complexity. A network-based software solution was developed targeting long-term process optimization by structural analysis and temporal coordination of process navigation. Each examination unit receives a separate waiting list of patients in which the patient flow for every patient is recorded in a timeline. Time periods and points in time can be executed by mouse clicks and the desired diagnostic procedure can be entered. Recent progress in any of these diagnostic requests, as well as a variety of information on patient progress are collated and drawn into the corresponding timeline which can be viewed by any of the personnel involved. The software called TimeElement has been successfully tested in the practical implemenation for several months. As an example the patient flow regarding time stamps of defined events for intravitreous injections on 250 patients was recorded and an average attendance time of 169.71 min was found, whereby the time was also automatically recorded for each individual stage. Recording of patient flow data is a fundamental component of patient flow management, waiting time reduction, patient flow navigation with time and coordination in particular regarding timeline-based visualization for each individual patient. Long-term changes in process management can be planned and evaluated by comparing patient flow data. As using the software itself causes structural changes within the organization, a questionnaire is being planned for appraisal by the personnel involved.

  11. Helios: History and Anatomy of a Successful In-House Enterprise High-Throughput Screening and Profiling Data Analysis System.

    PubMed

    Gubler, Hanspeter; Clare, Nicholas; Galafassi, Laurent; Geissler, Uwe; Girod, Michel; Herr, Guy

    2018-06-01

    We describe the main characteristics of the Novartis Helios data analysis software system (Novartis, Basel, Switzerland) for plate-based screening and profiling assays, which was designed and built about 11 years ago. It has been in productive use for more than 10 years and is one of the important standard software applications running for a large user community at all Novartis Institutes for BioMedical Research sites globally. A high degree of automation is reached by embedding the data analysis capabilities into a software ecosystem that deals with the management of samples, plates, and result data files, including automated data loading. The application provides a series of analytical procedures, ranging from very simple to advanced, which can easily be assembled by users in very flexible ways. This also includes the automatic derivation of a large set of quality control (QC) characteristics at every step. Any of the raw, intermediate, and final results and QC-relevant quantities can be easily explored through linked visualizations. Links to global assay metadata management, data warehouses, and an electronic lab notebook system are in place. Automated transfer of relevant data to data warehouses and electronic lab notebook systems are also implemented.

  12. Mobile applications for handheld devices to screen and randomize acute stroke patients in clinical trials.

    PubMed

    Qureshi, Ai; Connelly, B; Abbott, Ei; Maland, E; Kim, J; Blake, J

    2012-08-01

    The availability of internet connectivity and mobile application software used by low-power handheld devices makes smart phones of unique value in time-sensitive clinical trials. Trial-specific applications can be downloaded by investigators from various mobile software distribution platforms or web applications delivered over HTTP. The Antihypertensive Treatment in Acute Cerebral Hemorrhage (ATACH) II investigators in collaboration with MentorMate released the ATACH-II Patient Recruitment mobile application available on iPhone, Android, and Blackberry in 2011. The mobile application provides tools for pre-screening, assessment of eligibility, and randomization of patients. Since the release of ATACH-II mobile application, the CLEAR-IVH (Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage) trial investigators have also adopted such a mobile application. The video-conferencing capabilities of the most recent mobile devices open up additional opportunities to involve central coordinating centers in the recruitment process in real time.

  13. Blade counting tool with a 3D borescope for turbine applications

    NASA Astrophysics Data System (ADS)

    Harding, Kevin G.; Gu, Jiajun; Tao, Li; Song, Guiju; Han, Jie

    2014-07-01

    Video borescopes are widely used for turbine and aviation engine inspection to guarantee the health of blades and prevent blade failure during running. When the moving components of a turbine engine are inspected with a video borescope, the operator must view every blade in a given stage. The blade counting tool is video interpretation software that runs simultaneously in the background during inspection. It identifies moving turbine blades in a video stream, tracks and counts the blades as they move across the screen. This approach includes blade detection to identify blades in different inspection scenarios and blade tracking to perceive blade movement even in hand-turning engine inspections. The software is able to label each blade by comparing counting results to a known blade count for the engine type and stage. On-screen indications show the borescope user labels for each blade and how many blades have been viewed as the turbine is rotated.

  14. Recording blood pressure and eGFR in primary care after the Belgrade screening study.

    PubMed

    Lezaic, Visnja; Marinkovic, Jelena; Milutinovic, Zoran; Jovanovic-Vasiljevic, Nada; Vujicic, Vesna; Pejovic, Branka; Kalabic, Snezana; Djukanovic, Ljubica

    2018-11-01

    In 2009, Belgrade nephrologists and general practitioners from thirteen health centers carried out screening for chronic kidney disease (CKD). Three years later, medical records of patients from four health centers participating in the screening study were retrospectively analyzed in order to check whether general practitioners had continued to control patients at risk for CKD in accordance with the recommendations provided. The study included 460 patients who visited their doctor at least once in the three-year period. Data on blood pressure, ACEI use, estimated glomerular filtration rate (eGFR) and comorbidities were taken from patients' medical records. Blood pressure was not recorded in any of the three years in 42.8% and eGFR in 36.7% of the patients, but blood pressure was registered every year in 7.8% and eGFR in 4.3% of them. Over the three years, the relative number of patients with recorded blood pressure decreased from 41.7% to 17.8%, and with recorded eGFR from 41.7% to 21.5%. Multivariate linear regression found that Health Center, systolic and diastolic blood pressure and presence of hypertension were negatively associated with number of years with recorded blood pressure. Health Center, systolic blood pressure and sum of years with recorded eGFR below 60 ml/min/1.73m 2 were associated with number of years with recorded eGFR. Under-recording of blood pressure and eGFR in primary care health centers suggests lack of adherence to current guidelines and insufficient care of CKD patients. This implies the necessity for continuous education of physicians.

  15. Discussing uncertainty and risk in primary care: recommendations of a multi-disciplinary panel regarding communication around prostate cancer screening.

    PubMed

    Wilkes, Michael; Srinivasan, Malathi; Cole, Galen; Tardif, Richard; Richardson, Lisa C; Plescia, Marcus

    2013-11-01

    Shared decision making improves value-concordant decision-making around prostate cancer screening (PrCS). Yet, PrCS discussions remain complex, challenging and often emotional for physicians and average-risk men. In July 2011, the Centers for Disease Control and Prevention convened a multidisciplinary expert panel to identify priorities for funding agencies and development groups to promote evidence-based, value-concordant decisions between men at average risk for prostate cancer and their physicians. Two-day multidisciplinary expert panel in Atlanta, Georgia, with structured discussions and formal consensus processes. Sixteen panelists represented diverse specialties (primary care, medical oncology, urology), disciplines (sociology, communication, medical education, clinical epidemiology) and market sectors (patient advocacy groups, Federal funding agencies, guideline-development organizations). Panelists used guiding interactional and evaluation models to identify and rate strategies that might improve PrCS discussions and decisions for physicians, patients and health systems/society. Efficacy was defined as the likelihood of each strategy to impact outcomes. Effort was defined as the relative amount of effort to develop, implement and sustain the strategy. Each strategy was rated (1-7 scale; 7 = maximum) using group process software (ThinkTank(TM)). For each group, intervention strategies were grouped as financial/regulatory, educational, communication or attitudinal levers. For each strategy, barriers were identified. Highly ranked strategies to improve value-concordant shared decision-making (SDM) included: changing outpatient clinic visit reimbursement to reward SDM; development of evidence-based, technology-assisted, point-of-service tools for physicians and patients; reframing confusing prostate cancer screening messages; providing pre-visit decision support interventions; utilizing electronic health records to promote benchmarking/best practices; providing additional training for physicians around value-concordant decision-making; and using re-accreditation to promote training. Conference outcomes present an expert consensus of strategies likely to improve value-concordant prostate cancer screening decisions. In addition, the methodology used to obtain agreement provides a model of successful collaboration around this and future controversial cancer screening issues, which may be of interest to funding agencies, educators and policy makers.

  16. The Archival View of Technology: Resources for the Scholar of the Future.

    ERIC Educational Resources Information Center

    Zeidberg, David S.

    1999-01-01

    Archivists need to apply traditional principles of records management to electronic documents if these records are to survive for research by future scholars. Additionally, archivists must ensure that the electronic records preserved remain accessible as hardware and software change over time. (Author/AEF)

  17. Screening, Brief Intervention, and Referral to Treatment for Older Adults With Substance Misuse

    PubMed Central

    Hazlett, Robert W.; Hedgecock, Deborah K.; Duchene, Darran M.; Burns, L. Vance; Gum, Amber M.

    2015-01-01

    Objectives. We compared substance use and SBIRT (Screening, Brief Intervention, and Referral to Treatment) services received for older adults screened by the Florida BRITE (BRief Intervention and Treatment of Elders) Project, across 4 categories of service providers. Methods. Staff from 29 agencies screened for substance use risk in 75 sites across 18 Florida counties. Clients at no or low risk received feedback about screening; moderate risk led to brief intervention, moderate or high risk led to brief treatment, and highest severity led to referral to treatment. Six-month follow-ups were conducted with a random sample of clients. Results. Over 5 years (September 15, 2006–September 14, 2011), 85 001 client screenings were recorded. Of these, 8165 clients were at moderate or high risk. Most received brief intervention for alcohol or medication misuse. Differences were observed across 4 categories of agencies. Health educators screening solely within medical sites recorded fewer positive screens than those from mental health, substance abuse, or aging services that screened in a variety of community-based and health care sites. Six-month follow-ups revealed a significant decrease in substance use. Conclusions. The Florida BRITE Project demonstrated that SBIRT can be extended to nonmedical services that serve older adults. PMID:24832147

  18. "On-screen" writing and composing: two years experience with Manuscript Manager, Apple II and IBM-PC versions.

    PubMed

    Offerhaus, L

    1989-06-01

    The problems of the direct composition of a biomedical manuscript on a personal computer are discussed. Most word processing software is unsuitable because literature references, once stored, cannot be rearranged if major changes are necessary. These obstacles have been overcome in Manuscript Manager, a combination of word processing and database software. As it follows Council of Biology Editors and Vancouver rules, the printouts should be technically acceptable to most leading biomedical journals.

  19. Advanced human machine interaction for an image interpretation workstation

    NASA Astrophysics Data System (ADS)

    Maier, S.; Martin, M.; van de Camp, F.; Peinsipp-Byma, E.; Beyerer, J.

    2016-05-01

    In recent years, many new interaction technologies have been developed that enhance the usability of computer systems and allow for novel types of interaction. The areas of application for these technologies have mostly been in gaming and entertainment. However, in professional environments, there are especially demanding tasks that would greatly benefit from improved human machine interfaces as well as an overall improved user experience. We, therefore, envisioned and built an image-interpretation-workstation of the future, a multi-monitor workplace comprised of four screens. Each screen is dedicated to a complex software product such as a geo-information system to provide geographic context, an image annotation tool, software to generate standardized reports and a tool to aid in the identification of objects. Using self-developed systems for hand tracking, pointing gestures and head pose estimation in addition to touchscreens, face identification, and speech recognition systems we created a novel approach to this complex task. For example, head pose information is used to save the position of the mouse cursor on the currently focused screen and to restore it as soon as the same screen is focused again while hand gestures allow for intuitive manipulation of 3d objects in mid-air. While the primary focus is on the task of image interpretation, all of the technologies involved provide generic ways of efficiently interacting with a multi-screen setup and could be utilized in other fields as well. In preliminary experiments, we received promising feedback from users in the military and started to tailor the functionality to their needs

  20. Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software.

    PubMed

    Dos Reis, Felipe Jose Jandre; de Barros E Silva, Veronica; de Lucena, Raphaela Nunes; Mendes Cardoso, Bruno Alexandre; Nogueira, Leandro Calazans

    2016-01-01

    Pain drawings have frequently been used for clinical information and research. The aim of this study was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings. Our secondary objective was to verify the reliability when using computers with different screen sizes, both with and without mouse hardware. Pain drawings were completed by patients with chronic neck pain or neck-shoulder-arm pain. Four independent examiners participated in the study. Examiners A and B used the same computer with a 16-inch screen and wired mouse hardware. Examiner C used a notebook with a 16-inch screen and no mouse hardware, and Examiner D used a computer with an 11.6-inch screen and a wireless mouse. Image measurements were obtained using GIMP and NIH ImageJ computer programs. The length of all the images was measured using GIMP software to a set scale in ImageJ. Thus, each marked area was encircled and the total surface area (cm(2) ) was calculated for each pain drawing measurement. A total of 117 areas were identified and 52 pain drawings were analyzed. The intrarater reliability between all examiners was high (ICC = 0.989). The inter-rater reliability was also high. No significant differences were observed when using different screen sizes or when using or not using the mouse hardware. This suggests that the precision of these measurements is acceptable for the use of this method as a measurement tool in clinical practice and research. © 2014 World Institute of Pain.

  1. Software engineering and Ada in design

    NASA Technical Reports Server (NTRS)

    Oneill, Don

    1986-01-01

    Modern software engineering promises significant reductions in software costs and improvements in software quality. The Ada language is the focus for these software methodology and tool improvements. The IBM FSD approach, including the software engineering practices that guide the systematic design and development of software products and the management of the software process are examined. The revised Ada design language adaptation is revealed. This four level design methodology is detailed including the purpose of each level, the management strategy that integrates the software design activity with the program milestones, and the technical strategy that maps the Ada constructs to each level of design. A complete description of each design level is provided along with specific design language recording guidelines for each level. Finally, some testimony is offered on education, tools, architecture, and metrics resulting from project use of the four level Ada design language adaptation.

  2. Late Responders to Online Self-Report U.S. Air Force Occupational Health Screenings

    DTIC Science & Technology

    Health screening surveys play a key role in understanding military personnels perceived climate of their organization. These screenings provide...recorded after the final reminder email resulted in similar outcomes, and the extra week of data collection did not change results for either sample.

  3. An optogenetics- and imaging-assisted simultaneous multiple patch-clamp recording system for decoding complex neural circuits

    PubMed Central

    Wang, Guangfu; Wyskiel, Daniel R; Yang, Weiguo; Wang, Yiqing; Milbern, Lana C; Lalanne, Txomin; Jiang, Xiaolong; Shen, Ying; Sun, Qian-Quan; Zhu, J Julius

    2015-01-01

    Deciphering neuronal circuitry is central to understanding brain function and dysfunction, yet it remains a daunting task. To facilitate the dissection of neuronal circuits, a process requiring functional analysis of synaptic connections and morphological identification of interconnected neurons, we present here a method for stable simultaneous octuple patch-clamp recordings. This method allows physiological analysis of synaptic interconnections among 4–8 simultaneously recorded neurons and/or 10–30 sequentially recorded neurons, and it allows anatomical identification of >85% of recorded interneurons and >99% of recorded principal neurons. We describe how to apply the method to rodent tissue slices; however, it can be used on other model organisms. We also describe the latest refinements and optimizations of mechanics, electronics, optics and software programs that are central to the realization of a combined single- and two-photon microscopy–based, optogenetics- and imaging-assisted, stable, simultaneous quadruple–viguple patch-clamp recording system. Setting up the system, from the beginning of instrument assembly and software installation to full operation, can be completed in 3–4 d. PMID:25654757

  4. Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models.

    PubMed

    Sweeney, Sunya; Smith, Derek K; Messersmith, Marion

    2015-08-01

    One method of articulating digital models is to use a digitized interocclusal record. However, the accuracy of different interocclusal record materials to articulate digital models has yet to be evaluated. A plastic typodont was modified with reference points for interarch measurements and articulated in maximum intercuspal position on a semiadjustable hinge articulator. Twenty-five interocclusal records of each of the 5 experimental materials (Regisil Rigid, Dentsply, York, Pa; Futar Scan, Kettenbach, Huntington Beach, Calif; Byte Right, Motion View Software, Chattanooga, Tenn; Aluwax, Aluwax Dental Products, Allendale, Mich; and Beauty Pink wax, Miltex, York, Pa) were made on the mounted typodont and digitized using an Ortho Insight 3D laser surface scanner (Motion View Software). Motion View Software was used to articulate the digital models by matching points from the models to the digitized interocclusal records. The distances between corresponding interarch markers were measured and compared with the measurements taken on the physical typodont (gold standard). Polyvinyl siloxane materials were significantly more likely to lead to successful articulation than were the other interocclusal record materials. Statistical analysis showed a significant effect of the bite registration material on the probability of success of the articulation (P <0.005). Polyvinyl siloxane is a more accurate interocclusal recording material when articulating digital models according to the process described in this study. Using a bite registration to articulate digital models should be considered the first step in the articulation process, with a likely residual need to manipulate the models manually. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. Biblio-Link and Pro-Cite: The Searcher's Workstation.

    ERIC Educational Resources Information Center

    Hoyle, Norman; McNamara, Kathleen

    1987-01-01

    Describes the Biblio-Link and Pro-Cite software packages, which can be used together to create local databases with downloaded records, or to reorganize and repackage downloaded records for client reports. (CLB)

  6. Computer Bits: Child Care Center Management Software Buying Guide Update.

    ERIC Educational Resources Information Center

    Neugebauer, Roger

    1987-01-01

    Compares seven center management programs used for basic financial and data management tasks such as accounting, payroll and attendance records, and mailing lists. Describes three other specialized programs and gives guidelines for selecting the best software for a particular center. (NH)

  7. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting.

    PubMed

    van der Waal, Daniëlle; den Heeten, Gerard J; Pijnappel, Ruud M; Schuur, Klaas H; Timmers, Johanna M H; Verbeek, André L M; Broeders, Mireille J M

    2015-01-01

    The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation. Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50-75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]). Based on the BI-RADS classification, 40.8% of the women had 'heterogeneously or extremely dense' breasts. The median volumetric percent density was 12.1% (IQR: 9.6-16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4-10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04-5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra. Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized.

  8. GAPscreener: An automatic tool for screening human genetic association literature in PubMed using the support vector machine technique

    PubMed Central

    Yu, Wei; Clyne, Melinda; Dolan, Siobhan M; Yesupriya, Ajay; Wulf, Anja; Liu, Tiebin; Khoury, Muin J; Gwinn, Marta

    2008-01-01

    Background Synthesis of data from published human genetic association studies is a critical step in the translation of human genome discoveries into health applications. Although genetic association studies account for a substantial proportion of the abstracts in PubMed, identifying them with standard queries is not always accurate or efficient. Further automating the literature-screening process can reduce the burden of a labor-intensive and time-consuming traditional literature search. The Support Vector Machine (SVM), a well-established machine learning technique, has been successful in classifying text, including biomedical literature. The GAPscreener, a free SVM-based software tool, can be used to assist in screening PubMed abstracts for human genetic association studies. Results The data source for this research was the HuGE Navigator, formerly known as the HuGE Pub Lit database. Weighted SVM feature selection based on a keyword list obtained by the two-way z score method demonstrated the best screening performance, achieving 97.5% recall, 98.3% specificity and 31.9% precision in performance testing. Compared with the traditional screening process based on a complex PubMed query, the SVM tool reduced by about 90% the number of abstracts requiring individual review by the database curator. The tool also ascertained 47 articles that were missed by the traditional literature screening process during the 4-week test period. We examined the literature on genetic associations with preterm birth as an example. Compared with the traditional, manual process, the GAPscreener both reduced effort and improved accuracy. Conclusion GAPscreener is the first free SVM-based application available for screening the human genetic association literature in PubMed with high recall and specificity. The user-friendly graphical user interface makes this a practical, stand-alone application. The software can be downloaded at no charge. PMID:18430222

  9. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting

    PubMed Central

    van der Waal, Daniëlle; den Heeten, Gerard J.; Pijnappel, Ruud M.; Schuur, Klaas H.; Timmers, Johanna M. H.; Verbeek, André L. M.; Broeders, Mireille J. M.

    2015-01-01

    Introduction The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation. Materials and Methods Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50–75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]). Results Based on the BI-RADS classification, 40.8% of the women had ‘heterogeneously or extremely dense’ breasts. The median volumetric percent density was 12.1% (IQR: 9.6–16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4–10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04–5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra. Conclusion Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized. PMID:26335569

  10. Managing, profiling and analyzing a library of 2.6 million compounds gathered from 32 chemical providers.

    PubMed

    Monge, Aurélien; Arrault, Alban; Marot, Christophe; Morin-Allory, Luc

    2006-08-01

    The data for 3.8 million compounds from structural databases of 32 providers were gathered and stored in a single chemical database. Duplicates are removed using the IUPAC International Chemical Identifier. After this, 2.6 million compounds remain. Each database and the final one were studied in term of uniqueness, diversity, frameworks, 'drug-like' and 'lead-like' properties. This study also shows that there are more than 87 000 frameworks in the database. It contains 2.1 million 'drug-like' molecules among which, more than one million are 'lead-like'. This study has been carried out using 'ScreeningAssistant', a software dedicated to chemical databases management and screening sets generation. Compounds are stored in a MySQL database and all the operations on this database are carried out by Java code. The druglikeness and leadlikeness are estimated with 'in-house' scores using functions to estimate convenience to properties; unicity using the InChI code and diversity using molecular frameworks and fingerprints. The software has been conceived in order to facilitate the update of the database. 'ScreeningAssistant' is freely available under the GPL license.

  11. Presenting and discussing nuchal translucency screening for fetal abnormality in the UK.

    PubMed

    Pilnick, Alison M; Fraser, Diane M; James, David K

    2004-03-01

    to investigate the relationship between information giving by midwives and decision-making by women offered nuchal translucency (NT) screening. To establish how risk figures are discussed in practice, with the intention of relating this to the existing, and often critical, literature on women's accounts of antenatal screening. a qualitative study following women through the process of being offered and deciding to undergo NT screening. Tape recording of consultations, analysed in their entirety, was combined with post-screening interviews. a large teaching hospital in the UK. fourteen pregnant women eligible for NT screening at the time of recruitment. (i) tape recordings of consultations between community midwives and pregnant women where nuchal translucency screening was offered; (ii) tape recordings of consultations between hospital midwives and pregnant women immediately post-screening; (iii) individual face-to-face interviews with pregnant women between two and six weeks after the screening, carried out by the first author. NT screening was in general well received, particularly by those women who had undergone serum screening with previous pregnancies. However, communicating the nature of a risk figure is an interactionally complex process. A large amount of interactional work is required by midwives both before and after screening to ensure that women comprehend this information. Despite the emphasis placed in these consultations on understanding the purpose of NT screening and the status of the results, women often framed their decision to undergo NT screening in terms of it being a formality, or of presuming that all was well. This sometimes created practical and personal difficulties in terms of decision-making. previous sociological and psychological research has tended to be critical of midwives in terms of ensuring informed choice in screening, but this research is often based on post hoc accounts. Examining actual consultations with these accounts helps to illustrate the other factors that affect women's perceptions of testing, and the way in which risk, choice and decision-making are introduced and discussed in practice. Encouraging women to consider what action they might take on the basis of a personally unfavourable NT result in advance of undergoing the scan may help them to decide whether the information gained will be useful to them. Recognising the complex interactional work required in making sure that women understand the nature of the results that will be obtained is an important issue for the education and training of midwives.

  12. Automated toxicological screening reports of modified Agilent MSD Chemstation combined with Microsoft Visual Basic application programs.

    PubMed

    Choe, Sanggil; Kim, Suncheun; Choi, Hyeyoung; Choi, Hwakyoung; Chung, Heesun; Hwang, Bangyeon

    2010-06-15

    Agilent GC-MS MSD Chemstation offers automated library search report for toxicological screening using total ion chromatogram (TIC) and mass spectroscopy in normal mode. Numerous peaks appear in the chromatogram of biological specimen such as blood or urine and often large migrating peaks obscure small target peaks, in addition, any target peaks of low abundance regularly give wrong library search result or low matching score. As a result, retention time and mass spectrum of all the peaks in the chromatogram have to be checked to see if they are relevant. These repeated actions are very tedious and time-consuming to toxicologists. MSD Chemstation software operates using a number of macro files which give commands and instructions on how to work on and extract data from the chromatogram and spectroscopy. These macro files are developed by the own compiler of the software. All the original macro files can be modified and new macro files can be added to the original software by users. To get more accurate results with more convenient method and to save time for data analysis, we developed new macro files for reports generation and inserted new menus in the Enhanced Data Analysis program. Toxicological screening reports generated by these new macro files are in text mode or graphic mode and these reports can be generated with three different automated subtraction options. Text reports have Brief mode and Full mode and graphic reports have the option with or without mass spectrum mode. Matched mass spectrum and matching score for detected compounds are printed in reports by modified library searching modules. We have also developed an independent application program named DrugMan. This program manages drug groups, lists and parameters that are in use in MSD Chemstation. The incorporation of DrugMan with modified macro modules provides a powerful tool for toxicological screening and save a lot of valuable time on toxicological work. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  13. [Central online quality assurance in radiology: an IT solution exemplified by the German Breast Cancer Screening Program].

    PubMed

    Czwoydzinski, J; Girnus, R; Sommer, A; Heindel, W; Lenzen, H

    2011-09-01

    Physical-technical quality assurance is one of the essential tasks of the National Reference Centers in the German Breast Cancer Screening Program. For this purpose the mammography units are required to transfer the measured values of the constancy tests on a daily basis and all phantom images created for this purpose on a weekly basis to the reference centers. This is a serious logistical challenge. To meet these requirements, we developed an innovative software tool. By the end of 2005, we had already developed web-based software (MammoControl) allowing the transmission of constancy test results via entry forms. For automatic analysis and transmission of the phantom images, we then introduced an extension (MammoControl DIANA). This was based on Java, Java Web Start, the NetBeans Rich Client Platform, the Pixelmed Java DICOM Toolkit and the ImageJ library. MammoControl DIANA was designed to run locally in the mammography units. This allows automated on-site image analysis. Both results and compressed images can then be transmitted to the reference center. We developed analysis modules for the daily and monthly consistency tests and additionally for a homogeneity test. The software we developed facilitates the immediate availability of measurement results, phantom images, and DICOM header data in all reference centers. This allows both targeted guidance and short response time in the case of errors. We achieved a consistent IT-based evaluation with standardized tools for the entire screening program in Germany. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Electronic Health Record for Intensive Care based on Usual Windows Based Software.

    PubMed

    Reper, Arnaud; Reper, Pascal

    2015-08-01

    In Intensive Care Units, the amount of data to be processed for patients care, the turn over of the patients, the necessity for reliability and for review processes indicate the use of Patient Data Management Systems (PDMS) and electronic health records (EHR). To respond to the needs of an Intensive Care Unit and not to be locked with proprietary software, we developed an EHR based on usual software and components. The software was designed as a client-server architecture running on the Windows operating system and powered by the access data base system. The client software was developed using Visual Basic interface library. The application offers to the users the following functions: medical notes captures, observations and treatments, nursing charts with administration of medications, scoring systems for classification, and possibilities to encode medical activities for billing processes. Since his deployment in September 2004, the EHR was used to care more than five thousands patients with the expected software reliability and facilitated data management and review processes. Communications with other medical software were not developed from the start, and are realized by the use of basic functionalities communication engine. Further upgrade of the system will include multi-platform support, use of typed language with static analysis, and configurable interface. The developed system based on usual software components was able to respond to the medical needs of the local ICU environment. The use of Windows for development allowed us to customize the software to the preexisting organization and contributed to the acceptability of the whole system.

  15. A Framework for Evaluating the Software Product Quality of Pregnancy Monitoring Mobile Personal Health Records.

    PubMed

    Idri, Ali; Bachiri, Mariam; Fernández-Alemán, José Luis

    2016-03-01

    Stakeholders' needs and expectations are identified by means of software quality requirements, which have an impact on software product quality. In this paper, we present a set of requirements for mobile personal health records (mPHRs) for pregnancy monitoring, which have been extracted from literature and existing mobile apps on the market. We also use the ISO/IEC 25030 standard to suggest the requirements that should be considered during the quality evaluation of these mPHRs. We then go on to design a checklist in which we contrast the mPHRs for pregnancy monitoring requirements with software product quality characteristics and sub-characteristics in order to calculate the impact of these requirements on software product quality, using the ISO/IEC 25010 software product quality standard. The results obtained show that the requirements related to the user's actions and the app's features have the most impact on the external sub-characteristics of the software product quality model. The only sub-characteristic affected by all the requirements is Appropriateness of Functional suitability. The characteristic Operability is affected by 95% of the requirements while the lowest degrees of impact were identified for Compatibility (15%) and Transferability (6%). Lastly, the degrees of the impact of the mPHRs for pregnancy monitoring requirements are discussed in order to provide appropriate recommendations for the developers and stakeholders of mPHRs for pregnancy monitoring.

  16. Mapping HL7 CDA R2 Formatted Mass Screening Data to OpenEHR Archetypes.

    PubMed

    Kobayashi, Shinji; Kume, Naoto; Yoshihara, Hiroyuki

    2017-01-01

    Mass screening of adults was performed to manage employee healthcare. The screening service defined the data collection format as HL7 Clinical Document Architecture (CDA) R2. To capture mass screening data for nationwide electronic health records (her), we programmed a model within the CDA format and mapped the data items to the ISO13606/openEHR archetype for semantic interoperabiilty.

  17. Re-Writing the Construction History of Boughton House (northamptonshire, Uk) with the Help of DOCU-TOOLS®

    NASA Astrophysics Data System (ADS)

    Schuster, J. C.

    2017-08-01

    The tablet-based software docu-tools digitize the documentation of buildings, simplifies construction and facility management and the data analysis in building and construction-history research. As a plan-based software, `pins' can be set to record data (images, audio, text etc.), each data point containing a time and date stamp. Once a pin is set and information recorded, it can never be deleted from the system, creating clear contentious-free documentation. Reports to any/all data recorded can immediately be generated through various templates in order to share, document, analyze and archive the information gathered. The software both digitizes building condition assessment, as well as simplifies the fully documented management and solving of problems and monitoring of a building. Used both in the construction industry and for documenting and analyzing historic buildings, docu-tools is a versatile and flexible tool that has become integral to my work as a building historian working on the conservation and curating of the historic built environment in Europe. I used the software at Boughton House, Northamptonshire, UK, during a one-year research project into the construction history of the building. The details of how docu-tools was used during this project will be discussed in this paper.

  18. Perfusion Electronic Record Documentation Using Epic Systems Software.

    PubMed

    Riley, Jeffrey B; Justison, George A

    2015-12-01

    The authors comment on Steffens and Gunser's article describing the University of Wisconsin adoption of the Epic anesthesia record to include perfusion information from the cardiopulmonary bypass patient experience. We highlight the current-day lessons and the valuable quality and safety principles the Wisconsin-Epic model anesthesia-perfusion record provides.

  19. Software for real-time localization of baleen whale calls using directional sonobuoys: A case study on Antarctic blue whales.

    PubMed

    Miller, Brian S; Calderan, Susannah; Gillespie, Douglas; Weatherup, Graham; Leaper, Russell; Collins, Kym; Double, Michael C

    2016-03-01

    Directional frequency analysis and recording (DIFAR) sonobuoys can allow real-time acoustic localization of baleen whales for underwater tracking and remote sensing, but limited availability of hardware and software has prevented wider usage. These software limitations were addressed by developing a module in the open-source software PAMGuard. A case study is presented demonstrating that this software provides greater efficiency and accessibility than previous methods for detecting, localizing, and tracking Antarctic blue whales in real time. Additionally, this software can easily be extended to track other low and mid frequency sounds including those from other cetaceans, pinnipeds, icebergs, shipping, and seismic airguns.

  20. Industrial Waste Management Evaluation Model Version 3.1

    EPA Pesticide Factsheets

    IWEM is a screening level ground water model designed to simulate contaminant fate and transport. IWEM v3.1 is the latest version of the IWEM software, which includes additional tools to evaluate the beneficial use of industrial materials

  1. Cameras instead of sieves for aggregate characterization : research spotlight

    DOT National Transportation Integrated Search

    2012-01-01

    Michigan researchers explored the use of cameras and software that may eventually replace the use of screen sieves in sizing and assessing crushed aggregate for pavement construction. This research explored approaches to imaging aggregate as a way to...

  2. Pile Driving

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Machine-oriented structural engineering firm TERA, Inc. is engaged in a project to evaluate the reliability of offshore pile driving prediction methods to eventually predict the best pile driving technique for each new offshore oil platform. Phase I Pile driving records of 48 offshore platforms including such information as blow counts, soil composition and pertinent construction details were digitized. In Phase II, pile driving records were statistically compared with current methods of prediction. Result was development of modular software, the CRIPS80 Software Design Analyzer System, that companies can use to evaluate other prediction procedures or other data bases.

  3. Efficient radiologic reading environment by using an open-source macro program as connection software.

    PubMed

    Lee, Young Han

    2012-01-01

    The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. Post-processing open-source software for the CBCT monitoring of periapical lesions healing following endodontic treatment: technical report of two cases.

    PubMed

    Villoria, Eduardo M; Lenzi, Antônio R; Soares, Rodrigo V; Souki, Bernardo Q; Sigurdsson, Asgeir; Marques, Alexandre P; Fidel, Sandra R

    2017-01-01

    To describe the use of open-source software for the post-processing of CBCT imaging for the assessment of periapical lesions development after endodontic treatment. CBCT scans were retrieved from endodontic records of two patients. Three-dimensional virtual models, voxel counting, volumetric measurement (mm 3 ) and mean intensity of the periapical lesion were performed with ITK-SNAP v. 3.0 software. Three-dimensional models of the lesions were aligned and overlapped through the MeshLab software, which performed an automatic recording of the anatomical structures, based on the best fit. Qualitative and quantitative analyses of the changes in lesions size after treatment were performed with the 3DMeshMetric software. The ITK-SNAP v. 3.0 showed the smaller value corresponding to the voxel count and the volume of the lesion segmented in yellow, indicating reduction in volume of the lesion after the treatment. A higher value of the mean intensity of the segmented image in yellow was also observed, which suggested new bone formation. Colour mapping and "point value" tool allowed the visualization of the reduction of periapical lesions in several regions. Researchers and clinicians in the monitoring of endodontic periapical lesions have the opportunity to use open-source software.

  5. Use of GDNF-Releasing Nanofiber Nerve Guide Conduits for the Repair of Conus Medullaris/Cauda Equina Injury in the Non-Human Primate

    DTIC Science & Technology

    2013-10-01

    functional assessments using locomotor testing, urodynamic recordings, electromyography of the pelvic floor , and pain behavioral testing. At 18...selection, trained staff to perform the behavioral screening and evaluation, as well as successfully implementing our procedures for animal enrollment and...to the start of surgical procedures, each enrolled rhesus macaque underwent extensive screening and training . Behavioral records and profiles were

  6. Computer-Assisted Telephone Screening: A New System for Patient Evaluation and Recruitment

    PubMed Central

    Radcliffe, Jeanne M.; Latham, Georgia S.; Sunderland, Trey; Lawlor, Brian A.

    1990-01-01

    Recruitment of subjects for research studies is a time consuming process for any research coordinator. This paper introduces three computerized databases designed to help screen potential research candidates by telephone. The three programs discussed are designed to evaluate specific populations: geriatric patients (i.e. Alzheimer's patients), patients with affective disorders and normal volunteers. The interview content, software development, and the utility of these programs is discussed with particular focus on how they can be helpful in the research setting.

  7. The TI-99/4A Software.

    ERIC Educational Resources Information Center

    Wrege, Rachael; And Others

    1982-01-01

    Describes the software modules produced by Texas Instruments for use with the TI-99/4A home computer. Among the modules described are: Personal Real Estate, Programing Aids, Home Financial Decisions, Music Maker, Weight Control and Nutrition, Early Learning Fun, and Tax/Investment Record Keeping. (JL)

  8. User-friendly tools on handheld devices for observer performance study

    NASA Astrophysics Data System (ADS)

    Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi

    2012-02-01

    ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.

  9. Documenting the decision structure in software development

    NASA Technical Reports Server (NTRS)

    Wild, J. Christian; Maly, Kurt; Shen, Stewart N.

    1990-01-01

    Current software development paradigms focus on the products of the development process. Much of the decision making process which produces these products is outside the scope of these paradigms. The Decision-Based Software Development (DBSD) paradigm views the design process as a series of interrelated decisions which involve the identification and articulation of problems, alternates, solutions and justifications. Decisions made by programmers and analysts are recorded in a project data base. Unresolved problems are also recorded and resources for their resolution are allocated by management according to the overall development strategy. This decision structure is linked to the products affected by the relevant decision and provides a process oriented view of the resulted system. Software maintenance uses this decision view of the system to understand the rationale behind the decisions affecting the part of the system to be modified. D-HyperCase, a prototype Decision-Based Hypermedia System is described and results of applying the DBSD approach during its development are presented.

  10. Designing an Algorithm to Preserve Privacy for Medical Record Linkage With Error-Prone Data

    PubMed Central

    Pal, Doyel; Chen, Tingting; Khethavath, Praveen

    2014-01-01

    Background Linking medical records across different medical service providers is important to the enhancement of health care quality and public health surveillance. In records linkage, protecting the patients’ privacy is a primary requirement. In real-world health care databases, records may well contain errors due to various reasons such as typos. Linking the error-prone data and preserving data privacy at the same time are very difficult. Existing privacy preserving solutions for this problem are only restricted to textual data. Objective To enable different medical service providers to link their error-prone data in a private way, our aim was to provide a holistic solution by designing and developing a medical record linkage system for medical service providers. Methods To initiate a record linkage, one provider selects one of its collaborators in the Connection Management Module, chooses some attributes of the database to be matched, and establishes the connection with the collaborator after the negotiation. In the Data Matching Module, for error-free data, our solution offered two different choices for cryptographic schemes. For error-prone numerical data, we proposed a newly designed privacy preserving linking algorithm named the Error-Tolerant Linking Algorithm, that allows the error-prone data to be correctly matched if the distance between the two records is below a threshold. Results We designed and developed a comprehensive and user-friendly software system that provides privacy preserving record linkage functions for medical service providers, which meets the regulation of Health Insurance Portability and Accountability Act. It does not require a third party and it is secure in that neither entity can learn the records in the other’s database. Moreover, our novel Error-Tolerant Linking Algorithm implemented in this software can work well with error-prone numerical data. We theoretically proved the correctness and security of our Error-Tolerant Linking Algorithm. We have also fully implemented the software. The experimental results showed that it is reliable and efficient. The design of our software is open so that the existing textual matching methods can be easily integrated into the system. Conclusions Designing algorithms to enable medical records linkage for error-prone numerical data and protect data privacy at the same time is difficult. Our proposed solution does not need a trusted third party and is secure in that in the linking process, neither entity can learn the records in the other’s database. PMID:25600786

  11. Alcohol Screening among Opioid Agonist Patients in a Primary Care Clinic and an Opioid Treatment Program.

    PubMed

    Klimas, Jan; Muench, John; Wiest, Katharina; Croff, Raina; Rieckman, Traci; McCarty, Dennis

    2015-01-01

    Problem alcohol use is associated with adverse health and economic outcomes, especially among people in opioid agonist treatment. Screening, brief intervention, and referral to treatment (SBIRT) are effective in reducing alcohol use; however, issues involved in SBIRT implementation among opioid agonist patients are unknown. To assess identification and treatment of alcohol use disorders, we reviewed clinical records of opioid agonist patients screened for an alcohol use disorder in a primary care clinic (n = 208) and in an opioid treatment program (n = 204) over a two-year period. In the primary care clinic, 193 (93%) buprenorphine patients completed an annual alcohol screening and six (3%) had elevated AUDIT scores. In the opioid treatment program, an alcohol abuse or dependence diagnosis was recorded for 54 (27%) methadone patients. Practitioner focus groups were completed in the primary care (n = 4 physicians) and the opioid treatment program (n = 11 counselors) to assess experience with and attitudes towards screening opioid agonist patients for alcohol use disorders. Focus groups suggested that organizational, structural, provider, patient, and community variables hindered or fostered alcohol screening. Alcohol screening is feasible among opioid agonist patients. Effective implementation, however, requires physician training and systematic changes in workflow.

  12. Nutritional Screening of Children: A Manual for Screening & Followup.

    ERIC Educational Resources Information Center

    Bureau of Community Health Services (DHHS/PHS), Rockville, MD.

    This manual shows health providers how to perform precisely and expertly each step of several procedures used in screening children for nutritional problems. It is intended for all health providers who are involved in weighing and measuring children, recording and plotting measurements on growth charts, taking blood samples to test for iron…

  13. 77 FR 42323 - Notice of Proposed Information Collection for Public Comment; Screening and Eviction for Drug...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-18

    ... Information Collection for Public Comment; Screening and Eviction for Drug Abuse and Other Criminal Activity... collection requirements consist of PHA screening requirements to obtain criminal conviction records from law enforcement agencies to prevent admission of criminals into the public housing and Section 8 programs and to...

  14. Criminal Record Checks of Public School Employment Applicants.

    ERIC Educational Resources Information Center

    Titus, Richard M.; DeFrances, Carol J.

    This examination of preemployment screening in the American public school focuses on how legislation and other factors influence the kind of screening that is conducted, what problems schools have had to deal with in carrying out the screening, and what administrative and legislative changes may be suggested. A total of 1,122 public school…

  15. DockoMatic 2.0: high throughput inverse virtual screening and homology modeling.

    PubMed

    Bullock, Casey; Cornia, Nic; Jacob, Reed; Remm, Andrew; Peavey, Thomas; Weekes, Ken; Mallory, Chris; Oxford, Julia T; McDougal, Owen M; Andersen, Timothy L

    2013-08-26

    DockoMatic is a free and open source application that unifies a suite of software programs within a user-friendly graphical user interface (GUI) to facilitate molecular docking experiments. Here we describe the release of DockoMatic 2.0; significant software advances include the ability to (1) conduct high throughput inverse virtual screening (IVS); (2) construct 3D homology models; and (3) customize the user interface. Users can now efficiently setup, start, and manage IVS experiments through the DockoMatic GUI by specifying receptor(s), ligand(s), grid parameter file(s), and docking engine (either AutoDock or AutoDock Vina). DockoMatic automatically generates the needed experiment input files and output directories and allows the user to manage and monitor job progress. Upon job completion, a summary of results is generated by Dockomatic to facilitate interpretation by the user. DockoMatic functionality has also been expanded to facilitate the construction of 3D protein homology models using the Timely Integrated Modeler (TIM) wizard. The wizard TIM provides an interface that accesses the basic local alignment search tool (BLAST) and MODELER programs and guides the user through the necessary steps to easily and efficiently create 3D homology models for biomacromolecular structures. The DockoMatic GUI can be customized by the user, and the software design makes it relatively easy to integrate additional docking engines, scoring functions, or third party programs. DockoMatic is a free comprehensive molecular docking software program for all levels of scientists in both research and education.

  16. SARS: Safeguards Accounting and Reporting Software

    NASA Astrophysics Data System (ADS)

    Mohammedi, B.; Saadi, S.; Ait-Mohamed, S.

    In order to satisfy the requirements of the SSAC (State System for Accounting and Control of nuclear materials), for recording and reporting objectives; this computer program comes to bridge the gape between nuclear facilities operators and national inspection verifying records and delivering reports. The SARS maintains and generates at-facility safeguards accounting records and generates International Atomic Energy Agency (IAEA) safeguards reports based on accounting data input by the user at any nuclear facility. A database structure is built and BORLAND DELPHI programming language has been used. The software is designed to be user-friendly, to make extensive and flexible management of menus and graphs. SARS functions include basic physical inventory tacking, transaction histories and reporting. Access controls are made by different passwords.

  17. Observing Arctic Sea Ice from Bow to Screen: Introducing Ice Watch, the Data Network of Near Real-Time and Historic Observations from the Arctic Shipborne Sea Ice Standardization Tool (ASSIST)

    NASA Astrophysics Data System (ADS)

    Orlich, A.; Hutchings, J. K.; Green, T. M.

    2013-12-01

    The Ice Watch Program is an open source forum to access in situ Arctic sea ice conditions. It provides the research community and additional stakeholders a convenient resource to monitor sea ice and its role in understanding the Arctic as a system by implementing a standardized observation protocol and hosting a multi-service data portal. International vessels use the Arctic Shipborne Sea Ice Standardization Tool (ASSIST) software to report near-real time sea ice conditions while underway. Essential observations of total ice concentration, distribution of multi-year ice and other ice types, as well as their respective stage of melt are reported. These current and historic sea ice conditions are visualized on interactive maps and in a variety of statistical analyses, and with all data sets available to download for further investigation. The summer of 2012 was the debut of the ASSIST software and the Ice Watch campaign, with research vessels from six nations reporting from a wide spatio-temporal scale spanning from the Beaufort Sea, across the North Pole and Arctic Basin, the coast of Greenland and into the Kara and Barents Seas during mid-season melt and into the first stages of freeze-up. The 2013 summer field season sustained the observation and data archiving record, with participation from some of the same cruises as well as other geographic and seasonal realms covered by new users. These results are presented to illustrate the evolution of the program, increased participation and critical statistics of ice regime change and record of melt and freeze processes revealed by the data. As an ongoing effort, Ice Watch/ASSIST aims to standardize observations of Arctic-specific sea ice features and conditions while utilizing nomenclature and coding based on the World Meteorological Organization (WMO) standards and the Antarctic Sea Ice and Processes & Climate (ASPeCt) protocol. Instigated by members of the CliC Sea Ice Working Group, the program has evolved with coordination from the International Arctic Research Center, software development by the Geographic Information Network of Alaska, and funding support from the Japanese Aerospace Exploration Agency (JAXA), the Japan Agency for Marine-Earth Science & Technology (JAMSTEC), and the National Science Foundation (NSF).

  18. Impact of Ada and object-oriented design in the flight dynamics division at Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Waligora, Sharon; Bailey, John; Stark, Mike

    1995-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of applications software. The goals of the SEL are (1) to understand the software development process in the GSFC environment; (2) to measure the effects of various methodologies, tools, and models on this process; and (3) to identify and then to apply successful development practices. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  19. GCS programmer's manual

    NASA Technical Reports Server (NTRS)

    Lowman, Douglas S.; Withers, B. Edward; Shagnea, Anita M.; Dent, Leslie A.; Hayhurst, Kelly J.

    1990-01-01

    A variety of instructions to be used in the development of implementations of software for the Guidance and Control Software (GCS) project is described. This document fulfills the Radio Technical Commission for Aeronautics RTCA/DO-178A guidelines, 'Software Considerations in Airborne Systems and Equipment Certification' requirements for document No. 4, which specifies the information necessary for understanding and programming the host computer, and document No. 12, which specifies the software design and implementation standards that are applicable to the software development and testing process. Information on the following subjects is contained: activity recording, communication protocol, coding standards, change management, error handling, design standards, problem reporting, module testing logs, documentation formats, accuracy requirements, and programmer responsibilities.

  20. The software system development for the TAMU real-time fan beam scatterometer data processors

    NASA Technical Reports Server (NTRS)

    Clark, B. V.; Jean, B. R.

    1980-01-01

    A software package was designed and written to process in real-time any one quadrature channel pair of radar scatterometer signals form the NASA L- or C-Band radar scatterometer systems. The software was successfully tested in the C-Band processor breadboard hardware using recorded radar and NERDAS (NASA Earth Resources Data Annotation System) signals as the input data sources. The processor development program and the overall processor theory of operation and design are described. The real-time processor software system is documented and the results of the laboratory software tests, and recommendations for the efficient application of the data processing capabilities are presented.

  1. A qualitative study of anticipated barriers and facilitators to the implementation of nurse-delivered alcohol screening, brief intervention, and referral to treatment for hospitalized patients in a Veterans Affairs medical center

    PubMed Central

    2012-01-01

    Background Unhealthy alcohol use includes the spectrum of alcohol consumption from risky drinking to alcohol use disorders. Routine alcohol screening, brief intervention (BI) and referral to treatment (RT) are commonly endorsed for improving the identification and management of unhealthy alcohol use in outpatient settings. However, factors which might impact screening, BI, and RT implementation in inpatient settings, particularly if delivered by nurses, are unknown, and must be identified to effectively plan randomized controlled trials (RCTs) of nurse-delivered BI. The purpose of this study was to identify the potential barriers and facilitators associated with nurse-delivered alcohol screening, BI and RT for hospitalized patients. Methods We conducted audio-recorded focus groups with nurses from three medical-surgical units at a large urban Veterans Affairs Medical Center. Transcripts were analyzed using modified grounded theory techniques to identify key themes regarding anticipated barriers and facilitators to nurse-delivered screening, BI and RT in the inpatient setting. Results A total of 33 medical-surgical nurses (97% female, 83% white) participated in one of seven focus groups. Nurses consistently anticipated the following barriers to nurse-delivered screening, BI, and RT for hospitalized patients: (1) lack of alcohol-related knowledge and skills; (2) limited interdisciplinary collaboration and communication around alcohol-related care; (3) inadequate alcohol assessment protocols and poor integration with the electronic medical record; (4) concerns about negative patient reaction and limited patient motivation to address alcohol use; (5) questionable compatibility of screening, BI and RT with the acute care paradigm and nursing role; and (6) logistical issues (e.g., lack of time/privacy). Suggested facilitators of nurse-delivered screening, BI, and RT focused on provider- and system-level factors related to: (1) improved provider knowledge, skills, communication, and collaboration; (2) expanded processes of care and nursing roles; and (3) enhanced electronic medical record features. Conclusions RCTs of nurse-delivered alcohol BI for hospitalized patients should include consideration of the following elements: comprehensive provider education on alcohol screening, BI and RT; record-keeping systems which efficiently document and plan alcohol-related care; a hybrid model of implementation featuring active roles for interdisciplinary generalists and specialists; and ongoing partnerships to facilitate generation of additional evidence for BI efficacy in hospitalized patients. PMID:23186245

  2. Lecture-Capture Software and the Teaching of Soils

    NASA Astrophysics Data System (ADS)

    Brevik, Eric C.

    2014-05-01

    Several companies now offer software that can record academic lectures and place them on password-protected course websites for future review by students. Using lecture-capture software offers several advantages for the instructor and the students, including: 1) The ability for students who miss class for legitimate reasons (e.g., participation in school-sanctioned extra-curricular activities, illness or family emergencies) to get lecture materials by logging into the class website. This provides these students with a more complete exposure to the material than simply copying a classmate's notes. 2) The instructor is able to direct students who miss class for legitimate reasons to the recorded lecture rather than needing to spend time going over the material with those students and that recap does not end up being rushed. 3) The ability to address course conflicts for graduating seniors by allowing them to take the lecture portion of the class via recorded lecture. 4) Students who desire more in-depth learning are able to go back to selected portions of previous lectures to review and reconsider a topic of discussion or to fill in vague sections of their notes. There are also potential disadvantages to the use of lecture-capture software, including: 1) decreased student attendance in class because they feel they can watch class later at a time of their own choosing, 2) additional time spent by the instructor dealing with the technology, and 3) problems with hardware or software during class time that prevents recording a given day's lecture. These problems can often be addressed or justified relatively easily. If problem 1 is of concern to an instructor it can be addressed by blocking online access to individual students who have a poor record of class attendance. In the case of problem 2, the extra time spent with the technology is often offset by a reduction in time answering questions from students who have missed class. Problem 3 does happen, but in the author's experience it is fairly rare, representing less than 5% of class sessions per semester. Student comments have been overwhelmingly favorable towards the use of captured lectures since the technology was first adopted in the author's classes in 2009.

  3. Simplified three microphone acoustic test method

    USDA-ARS?s Scientific Manuscript database

    Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that could provide a quick comparison for rapid identifi...

  4. 78 FR 63135 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... system. The NPRM also proposed to require replacing the operational program software of certain... condition would not be adequately addressed by the proposed action. The manufacturer has issued new service... software of certain indicating/recording systems. The NPRM was prompted by numerous operator reports of...

  5. Improving Airline Safety

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Under a NASA-Ames Space Act Agreement, Coryphaeus Software and Simauthor, Inc., developed an Aviation Performance Measuring System (APMS). This software, developed for the aerospace and airline industry, enables the replay of Digital Flight Data Recorder (DFDR) data in a flexible, user-configurable, real-time, high fidelity 3D (three dimensional) environment.

  6. metAlignID: a high-throughput software tool set for automated detection of trace level contaminants in comprehensive LECO two-dimensional gas chromatography time-of-flight mass spectrometry data.

    PubMed

    Lommen, Arjen; van der Kamp, Henk J; Kools, Harrie J; van der Lee, Martijn K; van der Weg, Guido; Mol, Hans G J

    2012-11-09

    A new alternative data processing tool set, metAlignID, is developed for automated pre-processing and library-based identification and concentration estimation of target compounds after analysis by comprehensive two-dimensional gas chromatography with mass spectrometric detection. The tool set has been developed for and tested on LECO data. The software is developed to run multi-threaded (one thread per processor core) on a standard PC (personal computer) under different operating systems and is as such capable of processing multiple data sets simultaneously. Raw data files are converted into netCDF (network Common Data Form) format using a fast conversion tool. They are then preprocessed using previously developed algorithms originating from metAlign software. Next, the resulting reduced data files are searched against a user-composed library (derived from user or commercial NIST-compatible libraries) (NIST=National Institute of Standards and Technology) and the identified compounds, including an indicative concentration, are reported in Excel format. Data can be processed batch wise. The overall time needed for conversion together with processing and searching of 30 raw data sets for 560 compounds is routinely within an hour. The screening performance is evaluated for detection of pesticides and contaminants in raw data obtained after analysis of soil and plant samples. Results are compared to the existing data-handling routine based on proprietary software (LECO, ChromaTOF). The developed software tool set, which is freely downloadable at www.metalign.nl, greatly accelerates data-analysis and offers more options for fine-tuning automated identification toward specific application needs. The quality of the results obtained is slightly better than the standard processing and also adds a quantitative estimate. The software tool set in combination with two-dimensional gas chromatography coupled to time-of-flight mass spectrometry shows great potential as a highly-automated and fast multi-residue instrumental screening method. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. The time course of cancer detection performance

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, Sian; Clarke, Aileen; Wallis, Matthew; Wheaton, Margot; Duncan, Alison; Gale, Alastair G.

    2011-03-01

    The purpose of this study was to measure how mammography readers' performance varies with time of day and time spent reading. This was investigated in screening practice and when reading an enriched case set. In screening practice records of time and date that each case was read, along with outcome (whether the woman was recalled for further tests, and biopsy results where performed) was extracted from records from one breast screening centre in UK (4 readers). Patterns of performance with time spent reading was also measured using an enriched test set (160 cases, 41% malignant, read three times by eight radiologists). Recall rates varied with time of day, with different patterns for each reader. Recall rates decreased as the reading session progressed both when reading the enriched test set and in screening practice. Further work is needed to expand this work to a greater number of breast screening centres, and to determine whether these patterns of performance over time can be used to optimize overall performance.

  8. Comparison of alphabetical versus categorical display format for medication order entry in a simulated touch screen anesthesia information management system: an experiment in clinician-computer interaction in anesthesia.

    PubMed

    Marian, Anil A; Dexter, Franklin; Tucker, Peter; Todd, Michael M

    2012-05-29

    Anesthesia information management system (AIMS) records should be designed and configured to facilitate the accurate and prompt recording of multiple drugs administered coincidentally or in rapid succession. We proposed two touch-screen display formats for use with our department's new EPIC touch-screen AIMS. In one format, medication "buttons" were arranged in alphabetical order (i.e. A-C, D-H etc.). In the other, buttons were arranged in categories (Common, Fluids, Cardiovascular, Coagulation etc.). Both formats were modeled on an iPad screen to resemble the AIMS interface. Anesthesia residents, anesthesiologists, and Certified Registered Nurse Anesthetists (n = 60) were then asked to find and touch the correct buttons for a series of medications whose names were displayed to the side of the entry screen. The number of entries made within 2 minutes was recorded. This was done 3 times for each format, with the 1st format chosen randomly. Data were analyzed from the third trials with each format to minimize differences in learning. The categorical format had a mean of 5.6 more drugs entered using the categorical method in two minutes than the alphabetical format (95% confidence interval [CI] 4.5 to 6.8, P < 0.0001). The findings were the same regardless of the order of testing (i.e. alphabetical-categorical vs. categorical - alphabetical) and participants' years of clinical experience. Most anesthesia providers made no (0) errors for most trials (N = 96/120 trials, lower 95% limit 73%, P < 0.0001). There was no difference in error rates between the two formats (P = 0.53). The use of touch-screen user interfaces in healthcare is increasingly common. Arrangement of drugs names in a categorical display format in the medication order-entry touch screen of an AIMS can result in faster data entry compared to an alphabetical arrangement of drugs. Results of this quality improvement project were used in our department's design of our final intraoperative electronic anesthesia record. This testing approach using cognitive and usability engineering methods can be used to objectively design and evaluate many aspects of the clinician-computer interaction in electronic health records.

  9. Comparison of alphabetical versus categorical display format for medication order entry in a simulated touch screen anesthesia information management system: an experiment in clinician-computer interaction in anesthesia

    PubMed Central

    2012-01-01

    Background Anesthesia information management system (AIMS) records should be designed and configured to facilitate the accurate and prompt recording of multiple drugs administered coincidentally or in rapid succession. Methods We proposed two touch-screen display formats for use with our department’s new EPIC touch-screen AIMS. In one format, medication “buttons” were arranged in alphabetical order (i.e. A-C, D-H etc.). In the other, buttons were arranged in categories (Common, Fluids, Cardiovascular, Coagulation etc.). Both formats were modeled on an iPad screen to resemble the AIMS interface. Anesthesia residents, anesthesiologists, and Certified Registered Nurse Anesthetists (n = 60) were then asked to find and touch the correct buttons for a series of medications whose names were displayed to the side of the entry screen. The number of entries made within 2 minutes was recorded. This was done 3 times for each format, with the 1st format chosen randomly. Data were analyzed from the third trials with each format to minimize differences in learning. Results The categorical format had a mean of 5.6 more drugs entered using the categorical method in two minutes than the alphabetical format (95% confidence interval [CI] 4.5 to 6.8, P < 0.0001). The findings were the same regardless of the order of testing (i.e. alphabetical-categorical vs. categorical - alphabetical) and participants’ years of clinical experience. Most anesthesia providers made no (0) errors for most trials (N = 96/120 trials, lower 95% limit 73%, P < 0.0001). There was no difference in error rates between the two formats (P = 0.53). Conclusions The use of touch-screen user interfaces in healthcare is increasingly common. Arrangement of drugs names in a categorical display format in the medication order-entry touch screen of an AIMS can result in faster data entry compared to an alphabetical arrangement of drugs. Results of this quality improvement project were used in our department’s design of our final intraoperative electronic anesthesia record. This testing approach using cognitive and usability engineering methods can be used to objectively design and evaluate many aspects of the clinician-computer interaction in electronic health records. PMID:22643058

  10. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective ofmore » the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.« less

  11. Modern Corneal Eye-Banking Using a Software-Based IT Management Solution.

    PubMed

    Kern, C; Kortuem, K; Wertheimer, C; Nilmayer, O; Dirisamer, M; Priglinger, S; Mayer, W J

    2018-01-01

    Increasing government legislation and regulations in manufacturing have led to additional documentation regarding the pharmaceutical product requirements of corneal grafts in the European Union. The aim of this project was to develop a software within a hospital information system (HIS) to support the documentation process, to improve the management of the patient waiting list and to increase informational flow between the clinic and eye bank. After an analysis of the current documentation process, a new workflow and software were implemented in our electronic health record (EHR) system. The software takes over most of the documentation and reduces the time required for record keeping. It guarantees real-time tracing of all steps during human corneal tissue processing from the start of production until allocation during surgery and includes follow-up within the HIS. Moreover, listing of the patient for surgery as well as waiting list management takes place in the same system. The new software for corneal eye banking supports the whole process chain by taking over both most of the required documentation and the management of the transplant waiting list. It may provide a standardized IT-based solution for German eye banks working within the same HIS.

  12. How Do I Start a Property Records System?

    ERIC Educational Resources Information Center

    Whyman, Wynne

    2003-01-01

    A property records system organizes data to be utilized by a camp's facilities department and integrated into other areas. Start by deciding what records to keep and allotting the time. Then develop consistent procedures, including organizing data, creating a catalog, making back-up copies, and integrating procedures. Use software tools. A good…

  13. Golden Oldies: Using Digital Recording to Capture History

    ERIC Educational Resources Information Center

    Langhorst, Eric

    2008-01-01

    Analog audio recording has been around for a long time, but today's digital technology makes the process even easier, thanks to inexpensive equipment and free editing software. This year, the author's students at South Valley Junior High in Liberty, Missouri, will embark on an oral history project in which they will record their own family…

  14. The applicability of holography in forensic identification: a fusion of the traditional optical technique and digital technique.

    PubMed

    Biwasaka, Hitoshi; Saigusa, Kiyoshi; Aoki, Yasuhiro

    2005-03-01

    In this study, the applicability of holography in the 3-dimensional recording of forensic objects such as skulls and mandibulae, and the accuracy of the reconstructed 3-D images, were examined. The virtual holographic image, which records the 3-dimensional data of the original object, is visually observed on the other side of the holographic plate, and reproduces the 3-dimensional shape of the object well. Another type of holographic image, the real image, is focused on a frosted glass screen, and cross-sectional images of the object can be observed. When measuring the distances between anatomical reference points using an image-processing software, the average deviations in the holographic images as compared to the actual objects were less than 0.1 mm. Therefore, holography could be useful as a 3-dimensional recording method of forensic objects. Two superimposition systems using holographic images were examined. In the 2D-3D system, the transparent virtual holographic image of an object is directly superimposed onto the digitized photograph of the same object on the LCD monitor. On the other hand, in the video system, the holographic image captured by the CCD camera is superimposed onto the digitized photographic image using a personal computer. We found that the discrepancy between the outlines of the superimposed holographic and photographic dental images using the video system was smaller than that using the 2D-3D system. Holography seemed to perform comparably to the computer graphic system; however, a fusion with the digital technique would expand the utility of holography in superimposition.

  15. Data acquisition software for DIRAC experiment

    NASA Astrophysics Data System (ADS)

    Olshevsky, V.; Trusov, S.

    2001-08-01

    The structure and basic processes of data acquisition software of the DIRAC experiment for the measurement of π +π - atom lifetime are described. The experiment is running on the PS accelerator of CERN. The developed software allows one to accept, record and distribute up to 3 Mbytes of data to consumers in one accelerator supercycle of 14.4 s duration. The described system is successfully in use in the experiment since its startup in 1998.

  16. Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    PubMed

    Machado, Ana; Oliveira, Ana; Jácome, Cristina; Pereira, Marco; Moreira, José; Rodrigues, João; Aparício, José; Jesus, Luis M T; Marques, Alda

    2018-04-01

    The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of a new CALT for learning pulmonary auscultation. Computerized Lung Auscultation-Sound Software (CLASS) usability was assessed by eight physiotherapy students using computer screen recordings, think-aloud reports, and facial expressions. Time spent in each task, frequency of messages and facial expressions, number of clicks and problems reported were counted. The timelines of the three methods used were matched/synchronized and analyzed. The tasks exercises and annotation of respiratory sounds were the ones requiring more clicks (median 132, interquartile range [23-157]; 93 [53-155]; 91 [65-104], respectively) and where most errors (19; 37; 15%, respectively) and problems (n = 7; 6; 3, respectively) were reported. Each participant reported a median of 6 problems, with a total of 14 different problems found, mainly related with CLASS functionalities (50%). Smile was the only facial expression presented in all tasks (n = 54). CLASS is the only CALT available that meets all the required features for learning pulmonary auscultation. The combination of the three usability methods identified advantages/disadvantages of CLASS and offered guidance for future developments, namely in annotations and exercises. This will allow the improvement of CLASS and enhance students' activities for learning pulmonary auscultation skills.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basavatia, A; Kalnicki, S; Garg, M

    Purpose: To implement a clinically useful palm vein pattern recognition biometric system to treat the correct treatment plan to the correct patient each and every time and to check-in the patient into the department to access the correct medical record. Methods: A commercially available hand vein scanning system was paired to Aria and utilized an ADT interface from the hospital electronic health system. Integration at two points in Aria, version 11 MR2, first at the appointment tracker screen for the front desk medical record access and second at the queue screen on the 4D treatment console took place for patientmore » daily time-out. A test patient was utilized to check accuracy of identification as well as to check that no unintended interactions take place between the 4D treatment console and the hand vein scanning system. This system has been in clinical use since December 2013. Results: Since implementation, 445 patients have been enrolled into our biometric system. 95% of patients learn the correct methodology of hand placement on the scanner in the first try. We have had two instances of patient not found because of a bad initial scan. We simply erased the scanned metric and the patient enrolled again in those cases. The accuracy of the match is 100% for each patient, we have not had one patient misidentified. We can state this because we still use patient photo and date of birth as identifiers. A QA test patient is run monthly to check the integrity of the system. Conclusion: By utilizing palm vein scans along with the date of birth and patient photo, another means of patient identification now exits. This work indicates the successful implementation of technology in the area of patient safety by closing the gap of treating the wrong plan to a patient in radiation oncology. FOJP Service Corporation covered some of the costs of the hardware and software of the palm vein pattern recognition biometric system.« less

  18. Realization of Intelligent Measurement and Control System for Limb Rehabilitation Based on PLC and Touch Screen

    NASA Astrophysics Data System (ADS)

    Liu, Xiangquan

    According to the treatment needs of patients with limb movement disorder, on the basis of the limb rehabilitative training prototype, function of measure and control system are analyzed, design of system hardware and software is completed. The touch screen which is adopt as host computer and man-machine interaction window is responsible for sending commands and training information display; The PLC which is adopt as slave computer is responsible for receiving control command from touch screen, collecting the sensor data, regulating torque and speed of motor by analog output according to the different training mode, realizing ultimately active and passive training for limb rehabilitation therapy.

  19. Large Scale Bacterial Colony Screening of Diversified FRET Biosensors

    PubMed Central

    Litzlbauer, Julia; Schifferer, Martina; Ng, David; Fabritius, Arne; Thestrup, Thomas; Griesbeck, Oliver

    2015-01-01

    Biosensors based on Förster Resonance Energy Transfer (FRET) between fluorescent protein mutants have started to revolutionize physiology and biochemistry. However, many types of FRET biosensors show relatively small FRET changes, making measurements with these probes challenging when used under sub-optimal experimental conditions. Thus, a major effort in the field currently lies in designing new optimization strategies for these types of sensors. Here we describe procedures for optimizing FRET changes by large scale screening of mutant biosensor libraries in bacterial colonies. We describe optimization of biosensor expression, permeabilization of bacteria, software tools for analysis, and screening conditions. The procedures reported here may help in improving FRET changes in multiple suitable classes of biosensors. PMID:26061878

  20. Dysferlin quantification in monocytes for rapid screening for dysferlinopathies.

    PubMed

    Sánchez-Chapul, Laura; Ángel-Muñoz, Miguel Del; Ruano-Calderón, Luis; Luna-Angulo, Alexandra; Coral-Vázquez, Ramón; Hernández-Hernández, Óscar; Magaña, Jonathan J; León-Hernández, Saúl R; Escobar-Cedillo, Rosa E; Vargas, Steven

    2016-12-01

    In this study, we determined normal levels of dysferlin expression in CD14 + monocytes by flow cytometry (FC) as a screening tool for dysferlinopathies. Monocytes from 183 healthy individuals and 29 patients were immunolabeled, run on an FACScalibur flow cytometer, and analyzed by FlowJo software. The relative quantity of dysferlin was expressed as mean fluorescence intensity (MFI). Performance of this diagnostic test was assessed by calculating likelihood ratios at different MFI cut-off points, which allowed definition of 4 disease classification groups in a simplified algorithm. The MFI value may differentiate patients with dysferlinopathy from healthy individuals; it may be a useful marker for screening purposes. Muscle Nerve 54: 1064-1071, 2016. © 2016 Wiley Periodicals, Inc.

  1. Upgrading of data acquisition software for centralized radiation monitoring system in Malaysian Nuclear Agency

    NASA Astrophysics Data System (ADS)

    Yussup, F.; Ibrahim, M. M.; Haris, M. F.; Soh, S. C.; Hasim, H.; Azman, A.; Razalim, F. A. A.; Yapp, R.; Ramli, A. A. M.

    2016-01-01

    With the growth of technology, many devices and equipments can be connected to the network and internet to enable online data acquisition for real-time data monitoring and control from monitoring devices located at remote sites. Centralized radiation monitoring system (CRMS) is a system that enables area radiation level at various locations in Malaysian Nuclear Agency (Nuklear Malaysia) to be monitored centrally by using a web browser. The Local Area Network (LAN) in Nuclear Malaysia is utilized in CRMS as a communication media for data acquisition of the area radiation levels from radiation detectors. The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software upgrading on the system server that is responsible to acquire and record the area radiation readings from the detectors. The recorded readings are called in a web programming to be displayed on a website. Besides the main feature which is acquiring the area radiation levels in Nuclear Malaysia centrally, the upgrading involves new features such as uniform time interval for data recording and exporting, warning system and dose triggering.

  2. Image manipulation: Fraudulence in digital dental records: Study and review

    PubMed Central

    Chowdhry, Aman; Sircar, Keya; Popli, Deepika Bablani; Tandon, Ankita

    2014-01-01

    Introduction: In present-day times, freely available software allows dentists to tweak their digital records as never before. But, there is a fine line between acceptable enhancements and scientific delinquency. Aims and Objective: To manipulate digital images (used in forensic dentistry) of casts, lip prints, and bite marks in order to highlight tampering techniques and methods of detecting and preventing manipulation of digital images. Materials and Methods: Digital image records of forensic data (casts, lip prints, and bite marks photographed using Samsung Techwin L77 digital camera) were manipulated using freely available software. Results: Fake digital images can be created either by merging two or more digital images, or by altering an existing image. Discussion and Conclusion: Retouched digital images can be used for fraudulent purposes in forensic investigations. However, tools are available to detect such digital frauds, which are extremely difficult to assess visually. Thus, all digital content should mandatorily have attached metadata and preferably watermarking in order to avert their malicious re-use. Also, computer alertness, especially about imaging software's, should be promoted among forensic odontologists/dental professionals. PMID:24696587

  3. Metronome LKM: An open source virtual keyboard driver to measure experiment software latencies.

    PubMed

    Garaizar, Pablo; Vadillo, Miguel A

    2017-10-01

    Experiment software is often used to measure reaction times gathered with keyboards or other input devices. In previous studies, the accuracy and precision of time stamps has been assessed through several means: (a) generating accurate square wave signals from an external device connected to the parallel port of the computer running the experiment software, (b) triggering the typematic repeat feature of some keyboards to get an evenly separated series of keypress events, or (c) using a solenoid handled by a microcontroller to press the input device (keyboard, mouse button, touch screen) that will be used in the experimental setup. Despite the advantages of these approaches in some contexts, none of them can isolate the measurement error caused by the experiment software itself. Metronome LKM provides a virtual keyboard to assess an experiment's software. Using this open source driver, researchers can generate keypress events using high-resolution timers and compare the time stamps collected by the experiment software with those gathered by Metronome LKM (with nanosecond resolution). Our software is highly configurable (in terms of keys pressed, intervals, SysRq activation) and runs on 2.6-4.8 Linux kernels.

  4. Physically Based Rendering in the Nightshade NG Visualization Platform

    NASA Astrophysics Data System (ADS)

    Berglund, Karrie; Larey-Williams, Trystan; Spearman, Rob; Bogard, Arthur

    2015-01-01

    This poster describes our work on creating a physically based rendering model in Nightshade NG planetarium simulation and visualization software (project website: NightshadeSoftware.org). We discuss techniques used for rendering realistic scenes in the universe and dealing with astronomical distances in real time on consumer hardware. We also discuss some of the challenges of rewriting the software from scratch, a project which began in 2011.Nightshade NG can be a powerful tool for sharing data and visualizations. The desktop version of the software is free for anyone to download, use, and modify; it runs on Windows and Linux (and eventually Mac). If you are looking to disseminate your data or models, please stop by to discuss how we can work together.Nightshade software is used in literally hundreds of digital planetarium systems worldwide. Countless teachers and astronomy education groups run the software on flat screens. This wide use makes Nightshade an effective tool for dissemination to educators and the public.Nightshade NG is an especially powerful visualization tool when projected on a dome. We invite everyone to enter our inflatable dome in the exhibit hall to see this software in a 3D environment.

  5. Identification of fidgety movements and prediction of CP by the use of computer-based video analysis is more accurate when based on two video recordings.

    PubMed

    Adde, Lars; Helbostad, Jorunn; Jensenius, Alexander R; Langaas, Mette; Støen, Ragnhild

    2013-08-01

    This study evaluates the role of postterm age at assessment and the use of one or two video recordings for the detection of fidgety movements (FMs) and prediction of cerebral palsy (CP) using computer vision software. Recordings between 9 and 17 weeks postterm age from 52 preterm and term infants (24 boys, 28 girls; 26 born preterm) were used. Recordings were analyzed using computer vision software. Movement variables, derived from differences between subsequent video frames, were used for quantitative analysis. Sensitivities, specificities, and area under curve were estimated for the first and second recording, or a mean of both. FMs were classified based on the Prechtl approach of general movement assessment. CP status was reported at 2 years. Nine children developed CP of whom all recordings had absent FMs. The mean variability of the centroid of motion (CSD) from two recordings was more accurate than using only one recording, and identified all children who were diagnosed with CP at 2 years. Age at assessment did not influence the detection of FMs or prediction of CP. The accuracy of computer vision techniques in identifying FMs and predicting CP based on two recordings should be confirmed in future studies.

  6. Open source electronic health record and patient data management system for intensive care.

    PubMed

    Massaut, Jacques; Reper, Pascal

    2008-01-01

    In Intensive Care Units, the amount of data to be processed for patients care, the turn over of the patients, the necessity for reliability and for review processes indicate the use of Patient Data Management Systems (PDMS) and electronic health records (EHR). To respond to the needs of an Intensive Care Unit and not to be locked with proprietary software, we developed a PDMS and EHR based on open source software and components. The software was designed as a client-server architecture running on the Linux operating system and powered by the PostgreSQL data base system. The client software was developed in C using GTK interface library. The application offers to the users the following functions: medical notes captures, observations and treatments, nursing charts with administration of medications, scoring systems for classification, and possibilities to encode medical activities for billing processes. Since his deployment in February 2004, the PDMS was used to care more than three thousands patients with the expected software reliability and facilitated data management and review processes. Communications with other medical software were not developed from the start, and are realized by the use of the Mirth HL7 communication engine. Further upgrade of the system will include multi-platform support, use of typed language with static analysis, and configurable interface. The developed system based on open source software components was able to respond to the medical needs of the local ICU environment. The use of OSS for development allowed us to customize the software to the preexisting organization and contributed to the acceptability of the whole system.

  7. Improving detection of familial hypercholesterolaemia in primary care using electronic audit and nurse‐led clinics

    PubMed Central

    Neely, Dermot; Humphries, Steve E.; Saunders, Tanya; Gray, Val; Gordon, Louise; Payne, Jules; Carter, Slade; Neuwirth, Clare; Rees, Alan; Gallagher, Hazel

    2015-01-01

    Abstract Rationale, aims and objectives In the UK fewer than 15% of familial hypercholesterolemia (FH) cases are diagnosed, representing a major gap in coronary heart disease prevention. We wished to support primary care doctors within the Medway Clinical Commissioning Group (CCG) to implement NICE guidance (CG71) and consider the possibility of FH in adults who have raised total cholesterol concentrations, thereby improving the detection of people with FH. Methods Utilizing clinical decision support software (Audit+) we developed an FH Audit Tool and implemented a systematic audit of electronic medical records within GP practices, first identifying all patients diagnosed with FH or possible FH and next electronically flagging patients with a recorded total cholesterol of >7.5 mmol L−1 or LDL‐C > 4.9 mmol L−1 (in adults), for further assessment. After a 2‐year period, a nurse‐led clinic was introduced to screen more intensely for new FH index cases. We evaluated if these interventions increased the prevalence of FH closer to the expected prevalence from epidemiological studies. Results The baseline prevalence of FH within Medway CCG was 0.13% (1 in 750 persons). After 2 years, the recorded prevalence of diagnosed FH increased by 0.09% to 0.22% (1 in 450 persons). The nurse advisor programme ran for 9 months (October 2013–July 2014) and during this time, the recorded prevalence of patients diagnosed with FH increased to 0.28% (1 in 357 persons) and the prevalence of patients ‘at risk and unscreened’ reduced from 0.58% to 0.14%. Conclusions Our study shows that two simple interventions increased the detection of FH. This systematic yet simple electronic case‐finding programme with nurse‐led review allowed the identification of new index cases, more than doubling the recorded prevalence of detected disease to 1 in 357 (0.28%). This study shows that primary care has an important role in identifying patients with this condition. PMID:26608940

  8. Improvement of the user interface of multimedia applications by automatic display layout

    NASA Astrophysics Data System (ADS)

    Lueders, Peter; Ernst, Rolf

    1995-03-01

    Multimedia research has mainly focussed on real-time data capturing and display combined with compression, storage and transmission of these data. However, there is another problem considering real-time selecting and arranging a possibly large amount of data from multiple media on the computer screen together with textual and graphical data of regular software. This problem has already been known from complex software systems, such as CASE and hypertest, and will even be aggravated in multimedia systems. The aim of our work is to alleviate the user from the burden of continuously selecting, placing and sizing windows and their contents, but without introducing solutions limited to only few applications. We present an experimental system which controls the computer screen contents and layouts, directed by a user and/or tool provided information filter and prioritization. To be application independent, the screen layout is based on general layout optimization algorithms adapted from the VLSI layout which are controlled by application specific objective functions. In this paper, we discuss the problems of a comprehensible screen layout including the stability of optical information in time, the information filtering, the layout algorithms and the adaptation of the objective function to include a specific application. We give some examples of different standard applications with layout problems ranging from hierarchical graph layout to window layout. The results show that the automatic tool independent display layout will be possible in a real time interactive environment.

  9. A strategy for screening and identifying mycotoxins in herbal medicine using ultra-performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry.

    PubMed

    Fang, Lian-xiang; Xiong, Ai-zhen; Wang, Rui; Ji, Shen; Yang, Li; Wang, Zheng-tao

    2013-09-01

    The objective of this study was to develop an effective strategy for screening and identifying mycotoxins in herbal medicine (HM). Here, Imperatae Rhizoma, a commonly used Chinese herb, was selected as a model HM. A crude drug contaminated with fungi was analyzed by comparing with uncontaminated ones. Ultra-performance LC coupled to tandem quadrupole TOF-MS (UPLC-Q-TOF-MS) with collision energy function was applied to analyze different samples from Imperatae Rhizoma. Then, MarkerLynx(TM) software was employed to screen the excess components in analytes, compared with control samples, and those selected markers were likely to be the metabolites of fungi. Furthermore, each of the accurate masses of the markers obtained from MarkerLynx(TM) was then searched in a mycotoxins/fungal metabolites database established in advance. The molecular formulas with relative mass error between the measured and theoretical mass within 5 ppm were chosen and then applied to MassFragment(TM) analysis for further confirmation of their structures. With the use of this approach, five mycotoxins that have never been reported in HM were identified in contaminated Imperatae Rhizoma. The results demonstrate the potential of UPLC-Q-TOF-MS coupled with the MarkerLynx(TM) software and MassFragment(TM) tool as an efficient and convenient method to screen and identify mycotoxins in herbal materials and aid in the quality control of HM. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Using Semantic Templates to Study Vulnerabilities Recorded in Large Software Repositories

    ERIC Educational Resources Information Center

    Wu, Yan

    2011-01-01

    Software vulnerabilities allow an attacker to reduce a system's Confidentiality, Availability, and Integrity by exposing information, executing malicious code, and undermine system functionalities that contribute to the overall system purpose and need. With new vulnerabilities discovered everyday in a variety of applications and user environments,…

  11. Archiving a Software Development Project

    DTIC Science & Technology

    2013-04-01

    an ongoing monitoring system that identifies attempts and requests for retrieval, and ensures that the attempts and requests cannot proceed without...Intelligence Division Peter Fisher has worked as a consultant, systems analyst, software developer and project manager in Australia, Holland, the USA...4 3.1.3 DRMS – Defence Records Management System

  12. 48 CFR 52.227-14 - Rights in Data-General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... database or database means a collection of recorded information in a form capable of, and for the purpose... enable the computer program to be produced, created, or compiled. (2) Does not include computer databases... databases and computer software documentation). This term does not include computer software or financial...

  13. 48 CFR 52.227-14 - Rights in Data-General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... database or database means a collection of recorded information in a form capable of, and for the purpose... enable the computer program to be produced, created, or compiled. (2) Does not include computer databases... databases and computer software documentation). This term does not include computer software or financial...

  14. 48 CFR 52.227-14 - Rights in Data-General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... database or database means a collection of recorded information in a form capable of, and for the purpose... enable the computer program to be produced, created, or compiled. (2) Does not include computer databases... databases and computer software documentation). This term does not include computer software or financial...

  15. 48 CFR 52.227-14 - Rights in Data-General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... database or database means a collection of recorded information in a form capable of, and for the purpose... enable the computer program to be produced, created, or compiled. (2) Does not include computer databases... databases and computer software documentation). This term does not include computer software or financial...

  16. Data Capture and Analysis Using the BBC Microcomputer--an Interfacing Project Applied to Enzyme Kinetics.

    ERIC Educational Resources Information Center

    Jones, Lawrence; Graham, Ian

    1986-01-01

    Reviews the main principles of interfacing and discusses the software developed to perform kinetic data capture and analysis with a BBC microcomputer linked to a recording spectrophotometer. Focuses on the steps in software development. Includes results of a lactate dehydrogenase assay. (ML)

  17. Development of a tool for documenting, tracking, recording, and analyzing improvements to intersection sites and roadway departures in curve locations.

    DOT National Transportation Integrated Search

    2015-04-01

    The principal objectives and scope of this project were to provide a software tracking tool to improve : decision-making for highway safety. A literature search revealed that purchasing and customizing : existing software was not feasible and a new s...

  18. Radioactive Decay: Audio Data Collection

    ERIC Educational Resources Information Center

    Struthers, Allan

    2009-01-01

    Many phenomena generate interesting audible time series. This data can be collected and processed using audio software. The free software package "Audacity" is used to demonstrate the process by recording, processing, and extracting click times from an inexpensive radiation detector. The high quality of the data is demonstrated with a simple…

  19. 76 FR 52970 - In the Matter of Certain Biometric Scanning Devices, Components Thereof, Associated Software, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-720] In the Matter of Certain Biometric... accessing its Internet server at http://www.usitc.gov . The public record for this investigation may be... certain biometric scanning devices, components thereof, associated software, and products containing the...

  20. Software for objective comparison of vocal acoustic features over weeks of audio recording: KLFromRecordingDays

    NASA Astrophysics Data System (ADS)

    Soderstrom, Ken; Alalawi, Ali

    KLFromRecordingDays allows measurement of Kullback-Leibler (KL) distances between 2D probability distributions of vocal acoustic features. Greater KL distance measures reflect increased phonological divergence across the vocalizations compared. The software has been used to compare *.wav file recordings made by Sound Analysis Recorder 2011 of songbird vocalizations pre- and post-drug and surgical manipulations. Recordings from individual animals in *.wav format are first organized into subdirectories by recording day and then segmented into individual syllables uttered and acoustic features of these syllables using Sound Analysis Pro 2011 (SAP). KLFromRecordingDays uses syllable acoustic feature data output by SAP to a MySQL table to generate and compare "template" (typically pre-treatment) and "target" (typically post-treatment) probability distributions. These distributions are a series of virtual 2D plots of the duration of each syllable (as x-axis) to each of 13 other acoustic features measured by SAP for that syllable (as y-axes). Differences between "template" and "target" probability distributions for each acoustic feature are determined by calculating KL distance, a measure of divergence of the target 2D distribution pattern from that of the template. KL distances and the mean KL distance across all acoustic features are calculated for each recording day and output to an Excel spreadsheet. Resulting data for individual subjects may then be pooled across treatment groups and graphically summarized and used for statistical comparisons. Because SAP-generated MySQL files are accessed directly, data limits associated with spreadsheet output are avoided, and the totality of vocal output over weeks may be objectively analyzed all at once. The software has been useful for measuring drug effects on songbird vocalizations and assessing recovery from damage to regions of vocal motor cortex. It may be useful in studies employing other species, and as part of speech therapies tracking progress in producing distinct speech sounds in isolation.

Top