Sample records for screen serum samples

  1. Serum factors and clinical characteristics associated with serum E-Screen activity

    PubMed Central

    Wang, Jue; Trentham-Dietz, Amy; Hemming, Jocelyn D. C.; Hedman, Curtis J.; Sprague, Brian L.

    2013-01-01

    Background The E-Screen bioassay can measure the mitogenicity of human serum and thus may be useful as a biomarker in epidemiologic studies of breast cancer. While the assay’s MCF-7 cells are known to proliferate in response to estrogen, the specific determinants of variation in E-Screen activity in human serum samples are poorly understood. We sought to identify serum molecules and patient characteristics associated with serum E-Screen activity among postmenopausal women. Methods Postmenopausal women (N=219) aged 55–70 with no history of postmenopausal hormone use or breast cancer completed a questionnaire and provided a blood sample. Serum was analyzed for E-Screen activity and a variety of molecules including sex hormones, growth factors, and environmental chemicals. Stepwise selection procedures were used to identify correlates of E-Screen activity. Results Serum samples from all women had detectable E-Screen activity, with a median estradiol equivalents value of 0.027 ng/mL and interquartile range of 0.018–0.036 ng/mL. In the final multivariable-adjusted model, serum E-Screen activity was positively associated with serum estradiol, estrone, IGFBP-3, and testosterone levels (p<0.05), as well as body mass index (p=0.03). Serum E-Screen activity was lower among women with higher SHBG (p<0.0001) and progesterone levels (p=0.03). Conclusion Serum E-Screen activity varies according to levels of endogenous estrogens and other serum molecules. Obesity appears to confer additional serum mitogenicity beyond its impact on the measured hormones and growth factors. Impact By capturing mitogenicity due to a variety of patient and serum factors, the E-Screen may provide advantages for use as a biomarker in breast cancer studies. PMID:23588007

  2. Clinical Validation of a miRNA Blood Test to Identify High-Risk Individuals Eligible for Low-Dose Computed Tomography Screening for Lung Cancer Early Detection

    DTIC Science & Technology

    2015-10-01

    screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) undergoing...screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) that were collected

  3. EDRN Breast and Ovary Cancer CVC, Study 4: Phase 3 Validation of Ovarian Cancer Serum Markers in Preclinical WHI Samples — EDRN Public Portal

    Cancer.gov

    The WHI offers an opportunity to evaluate ovarian cancer markers and screening decision rules developed and validated in EDRN CVC Studies 2 and 3 in women who were not being screened. It is particularly well suited to validation of risk markers, since many serum samples were drawn well before clinical diagnosis of cancer in the WHI cohorts. A strategy is needed to identify from among the general population of women over the age of 50 those at high-risk for a diagnosis of ovarian/fallopian tube cancer so that they can be referred for appropriate surveillance, imaging or surgical consult. Tools to identify high-risk women will be investigated including serum markers CA125, HE4, MSLN, and MMP7 and epidemiologic risk factors. We will optimize decision rules using stored serum samples from the WHI OS and conduct a simulated prospective validation using stored serum samples from the WHI CT. Decision rules to select women for ovarian cancer screening will be investigated as well as decision rules for use in ovarian cancer screening.

  4. Chorionic villus sampling for abnormal screening compared to historical indications: prevalence of abnormal karyotypes.

    PubMed

    Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo

    2012-08-01

    To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.

  5. Potential of cancer screening with serum surface-enhanced Raman spectroscopy and a support vector machine

    NASA Astrophysics Data System (ADS)

    Li, S. X.; Zhang, Y. J.; Zeng, Q. Y.; Li, L. F.; Guo, Z. Y.; Liu, Z. M.; Xiong, H. L.; Liu, S. H.

    2014-06-01

    Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA-SVM methods. The results prove that a RBF kernel PCA-SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample.

  6. Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma

    PubMed Central

    Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.

    2010-01-01

    BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615

  7. [Presence of west Nile virus in northeast Mexico].

    PubMed

    Fernández-Salas, Ildefonso; de Lourdes Garza-Rodríguez, María; Beaty, Barry J; Jiménez, Javier Ramos; Rivas-Estilla, Ana María

    2007-01-01

    To investigate the presence of WNV in birds, horses and humans in northeast Mexico. Serum samples from 33 birds, 24 horses and 237 humans were screened by ELISA for Anti-WNV antibodies. Human serum samples were also screened for WNV RNA using an RT-PCR assay. Positive sera were found in three birds and 15 horses. Forty percent of the human serum samples were positive for IgG antibodies and 0% for IgM antibodies and viral RNA. The results of this study show that WNV is present in northeast Mexico and it is a new emergent infectious agent that represents a challenge for research and prevention programs in Mexico.

  8. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    PubMed Central

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Objective Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Methods Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. Results A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. Conclusion A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC. PMID:26487969

  9. Canine cancer screening via ultraviolet absorbance and fluorescence spectroscopy of serum proteins

    NASA Astrophysics Data System (ADS)

    Dickerson, Bryan D.; Geist, Brian L.; Spillman, William B., Jr.; Robertson, John L.

    2007-11-01

    A cost-effective optical cancer screening and monitoring technique was demonstrated in a pilot study of canine serum samples and was patented for commercialization. Compared to conventional blood chemistry analysis methods, more accurate estimations of the concentrations of albumin, globulins, and hemoglobin in serum were obtained by fitting the near UV absorbance and photoluminescence spectra of diluted serum as a linear combination of component reference spectra. Tracking these serum proteins over the course of treatment helped to monitor patient immune response to carcinoma and therapy. For cancer screening, 70% of dogs with clinical presentation of cancer displayed suppressed serum hemoglobin levels (below 20 mg/dL) in combination with atypical serum protein compositions, that is, albumin levels outside of a safe range (from 4 to 8 g/dL) and globulin levels above or below a more normal range (from 1.7 to 3.7 g/dL). Of the dogs that met these criteria, only 20% were given a false positive label by this cancer screening test.

  10. Detection of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Pools of Sera Negative for Antibodies to HIV-1 and HIV-2

    PubMed Central

    Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc

    1998-01-01

    A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372

  11. Placental Transfer of Maternally-Derived IgA Precludes the Use of Guthrie Card Eluates as a Screening Tool for Primary Immunodeficiency Diseases

    PubMed Central

    Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart

    2012-01-01

    There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases. PMID:22916257

  12. Placental transfer of maternally-derived IgA precludes the use of guthrie card eluates as a screening tool for primary immunodeficiency diseases.

    PubMed

    Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart

    2012-01-01

    There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases.

  13. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    PubMed

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  14. Gastrointestinal parasites of feral cats from Christmas Island.

    PubMed

    Adams, P J; Elliot, A D; Algar, D; Brazell, R I

    2008-01-01

    To investigate the gastrointestinal parasites present in feral cats on Christmas Island, with particular interest in the protozoan parasite Toxoplasma gondii. Faecal and serum samples were collected from 28 and 25 cats respectively that were trapped as part of an ongoing eradication program being run on Christmas Island by the Department of Environment and Conservation. Faecal samples were screened microscopically for helminth and protozoan parasites. Serum samples were screened for antibodies to T gondii using a commercial indirect immunofluorescence assay (IFA) and a latex agglutination test (LAT). The most common helminth parasites detected were Toxocara cati (present in 15 of 28 faecal samples), Strongyloides sp (13/28), Aelurostrongylus abstrusus, (7/28), an unidentified capillarid (6/28) and Ancylostoma sp (4/28). Based on serology, T gondii was the most common parasite detected (protozoan or otherwise) with antibodies detected in 24 serum samples by IFA and 23 serum samples by LAT. Cats on Christmas Island harbour many of the helminth and protozoan parasites reported from feral cats elsewhere in Australia. The high seroprevalence of T gondii in these cats indicates a high level of exposure to the parasite in this environment.

  15. Occurrence of West Nile virus antibodies in wild birds, horses, and humans in Poland.

    PubMed

    Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna

    2015-01-01

    Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland.

  16. Occurrence of West Nile Virus Antibodies in Wild Birds, Horses, and Humans in Poland

    PubMed Central

    Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna

    2015-01-01

    Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland. PMID:25866767

  17. Qualification of serological infectious disease assays for the screening of samples from deceased tissue donors.

    PubMed

    Kitchen, A D; Newham, J A

    2011-05-01

    Whilst some of the assays used for serological screening of post-mortem blood samples from deceased tissue donors in some countries have been specifically validated by the manufacturer for this purpose, a significant number of those currently in use globally have not. Although specificity has previously been considered a problem in the screening of such samples, we believe that ensuring sensitivity is more important. The aim of this study was to validate a broader range of assays for the screening of post-mortem blood samples from deceased tissue donors. Six microplate immunoassays currently in use within National Health Service Blood and Transplant (NHSBT) for the screening of blood, tissue and stem cell donations were included. Representative samples from confirmed positive donors were titrated in screen negative post-mortem samples in parallel with normal pooled negative serum to determine if there was any inhibition with the post-mortem samples. There were no significant differences seen (P < 0.005) between the dilution curves obtained for the positive samples diluted in post-mortem samples and normal pooled sera. Although small numbers of samples were studied, it can be surmised that the post-mortem blood samples from deceased tissue donors, collected according to United Kingdom guidelines, are a suitable substrate for the assays evaluated. No diminution of reactivity was seen when dilution with sera from deceased donors was compared to dilution using pooled serum from live donors. In the absence of genuine low titre positive post-mortem samples, the use of samples spiked with various levels of target material provides a means of qualifying serological screening assays used by NHSBT for the screening of post-mortem blood samples from deceased tissue donors.

  18. Serum allergen-specific immunoglobulin E in atopic and healthy cats: comparison of a rapid screening immunoassay and complete-panel analysis.

    PubMed

    Diesel, Alison; DeBoer, Douglas J

    2011-02-01

    Feline and canine atopic dermatitis are thought to have a similar immunopathogenesis. As with dogs, detection of allergen-specific IgE in cat serum merely supports a diagnosis of feline atopy based on compatible history, clinical signs and elimination of other pruritic dermatoses. In this study, a rapid screening immunoassay (Allercept(®) E-Screen 2nd Generation; Heska AG, Fribourg, Switzerland; ES2G) was compared with a complete-panel serum allergen-specific IgE assay (Allercept(®); Heska AG; CP) in healthy cats with no history of skin disease and in atopic cats. The latter had no diagnosis of external parasitism, infection, food hypersensitivity or other skin disease explaining their pruritus, and expressed cutaneous reaction patterns typically associated with feline allergic skin disease (head, neck or pinnal pruritus, miliary dermatitis, self-induced alopecia, eosinophilic granuloma complex). The proportion of cats positive on either the ES2G or the CP assays was not significantly different between the atopic and healthy cat groups. There was, however, strong agreement between the results of the ES2G and CP assay; overall, the two tests were in agreement for 43 of 49 (88%) serum samples. There was also strong agreement when individual allergen groups were evaluated (agreement noted: indoor, 41 of 49 samples; grasses/weeds, 37 of 49 samples; and trees, 41 of 49 samples). These results indicate that although neither test is diagnostic for feline atopic dermatitis, the screening assay is beneficial for predicting the results of a complete-panel serum allergen-specific IgE assay in cats. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.

  19. A Proposed Method to Predict Preterm Birth Using Clinical Data, Standard Maternal Serum Screening, and Cholesterol

    PubMed Central

    ALLEMAN, Brandon W.; SMITH, Amanda R.; BYERS, Heather M.; BEDELL, Bruce; RYCKMAN, Kelli K.; MURRAY, Jeffrey C.; BOROWSKI, Kristi S.

    2013-01-01

    Objective To create a predictive model for preterm birth (PTB) from available clinical data and serum analytes. Study Design Serum analytes, routine pregnancy screening plus cholesterol and corresponding health information were linked to birth certificate data for a cohort of 2699 Iowa women with serum sampled in the first and second trimester. Stepwise logistic regression was used to select the best predictive model for PTB. Results Serum screening markers remained significant predictors of PTB even after controlling for maternal characteristics. The best predictive model included maternal characteristics, first trimester total cholesterol (TC), TC change between trimesters and second trimester alpha-fetoprotein and inhibin A. The model showed better discriminatory ability than PTB history alone and performed similarly in subgroups of women without past PTB. Conclusions Using clinical and serum screening data a potentially useful predictor of PTB was constructed. Validation and replication in other populations, and incorporation of other measures that identify PTB risk, like cervical length, can be a step towards identifying additional women who may benefit from new or currently available interventions. PMID:23500456

  20. Screening for chromosomal anomalies in the first trimester: does repeat maternal serum screening improve detection rates?

    PubMed

    Spencer, Kevin; Cuckle, Howard S

    2002-10-01

    To assess the within person biological variability of first trimester maternal serum biochemical markers of trisomy 21 across the 10-14 week gestational period. To evaluate whether repeat sampling and testing of free beta-hCG and PAPP-A during this period would result in an improved detection rate. Women presenting at the first trimester OSCAR clinic have blood collected prior to ultrasound dating and nuchal translucency measurement. All samples are analysed for free beta-hCG and PAPP-A before an accurate estimate of gestation is available. In 10% of cases the gestation is prior to the minimum time for NT measurement (11 weeks) and these women are rebooked for a repeat visit to the clinic at the appropriate time. Our fetal database was interrogated to obtain cases in which two maternal blood samples had been collected and analysed in the 10-14 week period. Using data from the marker correlations and statistical modelling, the impact of repeat testing on detection rate for trisomy 21 at a fixed 5% false positive rate, was assessed. 261 pairs of data were available for analysis collected over a 3 year period. The correlation between free beta-hCG in sample 1 and sample 2 was 0.890 and that for PAPP-A was 0.827. The average within person biological variation for free beta-hCG was 21% and 32% for PAPP-A. The increase in detection rate when using both sets of marker data was 3.5% when using serum biochemistry and maternal age, and 1.3% when using nuchal translucency, serum biochemistry and maternal age. Repeat sampling and testing of maternal serum biochemical markers is unlikely to substantially improve first trimester screening performance. Copyright 2002 John Wiley & Sons, Ltd.

  1. Screening the low molecular weight fraction of human serum using ATR-IR spectroscopy.

    PubMed

    Bonnier, Franck; Brachet, Guillaume; Duong, Romain; Sojinrin, Tobiloba; Respaud, Renaud; Aubrey, Nicolas; Baker, Matthew J; Byrne, Hugh J; Chourpa, Igor

    2016-10-01

    Vibrational spectroscopic techniques can detect small variations in molecular content, linked with disease, showing promise for screening and early diagnosis. Biological fluids, particularly blood serum, are potentially valuable for diagnosis purposes. The so-called Low Molecular Weight Fraction (LMWF) contains the associated peptidome and metabolome and has been identified as potentially the most relevant molecular population for disease-associated biomarker research. Although vibrational spectroscopy can deliver a specific chemical fingerprint of the samples, the High Molecular Weight Fraction (HMWF), composed of the most abundant serum proteins, strongly dominates the response and ultimately makes the detection of minor spectral variations a challenging task. Spectroscopic detection of potential serum biomarkers present at relatively low concentrations can be improved using pre-analytical depletion of the HMWF. In the present study, human serum fractionation by centrifugal filtration was used prior to analysis by Attenuated Total Reflection infrared spectroscopy. Using a model sample based on glycine spiked serum, it is demonstrated that the screening of the LMWF can be applied to quantify blinded concentrations up to 50 times lower. Moreover, the approach is easily transferable to different bodily fluids which would support the development of more efficient and suitable clinical protocols exploring vibrational spectroscopy based ex-vivo diagnostic tools. Revealing serum LMWF for spectral serological diagnostic applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Noninvasive prostate cancer screening based on serum surface-enhanced Raman spectroscopy and support vector machine

    NASA Astrophysics Data System (ADS)

    Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao

    2014-09-01

    This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.

  3. Weak cation exchange magnetic beads coupled with matrix-assisted laser desorption ionization-time of flight-mass spectrometry in screening serum protein markers in osteopenia.

    PubMed

    He, Wei-Tao; Liang, Bo-Cheng; Shi, Zhen-Yu; Li, Xu-Yun; Li, Chun-Wen; Shi, Xiao-Lin

    2016-01-01

    The present study aimed at investigating the weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of osteopenia from ten postmenopausal women and ten postmenopausal women without osteopenia as control group, to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were collected from postmenopausal women with osteopenia and postmenopausal women with normal bone mass. Proteins were extracted from serum samples by weak cation exchange magnetic beads technology, and mass spectra acquisition was done by MALDI-TOF-MS. The visualization and comparison of data sets, statistical peak evaluation, model recognition, and discovery of biomarker candidates were handled by the proteinchip data analysis system software(ZJU-PDAS). The diagnostic models were established using genetic arithmetic based support vector machine (SVM). The SVM result with the highest Youden Index was selected as the model. Combinatorial Peaks having the highest accuracy in distinguishing different samples were selected as potential biomarker. From the two group serum samples, a total of 133 differential features were selected. Ten features with significant intensity differences were screened. In the pair-wise comparisons, processing of MALDI-TOF spectra resulted in the identification of ten differential features between postmenopausal women with osteopenia and postmenopausal women with normal bone mass. The difference of features by Youden index showed that the highest features had a mass to charge ratio of 1699 and 3038 Da. A diagnosis model was established with these two peaks as the candidate marker, and the specificity of the model is 100 %, the sensitivity was 90 % by leave-one-out cross validation test. The two groups of specimens in SVM results on the scatter plot could be clearly distinguished. The peak with m/z 3038 in the SVM model was suggested as Secretin by TagIdent tool. To provide further validation, the secretin levels in serum were analyzed using enzyme-linked immunosorbent assays that is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of secretin in human serum.

  4. Sub-tesla-field magnetization of vibrated magnetic nanoreagents for screening tumor markers

    NASA Astrophysics Data System (ADS)

    Chieh, Jen-Jie; Huang, Kai-Wen; Shi, Jin-Cheng

    2015-02-01

    Magnetic nanoreagents (MNRs), consisting of liquid solutions and magnetic nanoparticles (MNPs) coated with bioprobes, have been widely used in biomedical disciplines. For in vitro tests of serum biomarkers, numerous MNR-based magnetic immunoassay methods or schemes have been developed; however, their applications are limited. In this study, a vibrating sample magnetometer (VSM) was used for screening tumor biomarkers based on the same MNRs as those used in other immunoassay methods. The examination mechanism is that examined tumor biomarkers are typically conjugated to the bioprobes coated on MNPs to form magnetic clusters. Consequently, the sub-Tesla-field magnetization (Msub-T) of MNRs, including magnetic clusters, exceeds that of MNRs containing only separate MNPs. For human serum samples, proteins other than the targeted biomarkers induce the formation of magnetic clusters with increased Msub-T because of weak nonspecific binding. In this study, this interference problem was suppressed by the vibration condition in the VSM and analysis. Based on a referenced Msub-T,0 value defined by the average Msub-T value of a normal person's serum samples, including general proteins and few tumor biomarkers, the difference ΔMsub-T between the measured Msub-T and the reference Msub-T,0 determined the expression of only target tumor biomarkers in the tested serum samples. By using common MNRs with an alpha-fetoprotein-antibody coating, this study demonstrated that a current VSM can perform clinical screening of hepatocellular carcinoma.

  5. Systematic forensic toxicological analysis by liquid-chromatography-quadrupole-time-of-flight mass spectrometry in serum and comparison to gas chromatography-mass spectrometry.

    PubMed

    Grapp, Marcel; Kaufmann, Christoph; Streit, Frank; Binder, Lutz

    2018-06-01

    Comprehensive screening procedures for psychoactive agents in body fluids are an essential task in clinical and forensic toxicology. With the continuous emergence and adaption of new psychoactive substances (NPS) keeping a screening method up to date is challenging. To meet these demands, hyphenated high-resolution mass spectrometry has gained interest as extensive and expandable screening approach. Here we present a comprehensive method for systematic toxicological analysis of serum by liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) with data independent acquisition. The potential of this method was demonstrated by analysis of 247 authentic serum- and 12 post-mortem femoral blood samples. Thus 950 compounds, comprising 185 different drugs and metabolites could be identified. For the detected substances, including pharmaceutical substances, illicit drugs as well as NPS, serum concentrations were confirmed ranging from traces to toxic values indicating the capability for forensic toxicological requirements. Positive identification of drugs was achieved by accurate mass measurement (±5ppm for [M+H] + ; ±10ppm for [M-H] - ), retention time (±0.35min), isotopic pattern match (less than 10 m/z RMS [ppm]), isotope match intensity (less than 20% RMS) and the presence of at least two fragment ions. The LC-QTOF-MS procedure was shown to be superior to serum screening by GC-MS, since 240% (335 versus 141) more drugs were identified in serum samples compared to GC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry

    PubMed Central

    Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham

    2013-01-01

    A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507

  7. Use of finger-prick dried blood spots (fpDBS) and capillary electrophoresis for carbohydrate deficient transferrin (CDT) screening in forensic toxicology.

    PubMed

    Bertaso, Anna; Sorio, Daniela; Vandoros, Anthula; De Palo, Elio F; Bortolotti, Federica; Tagliaro, Franco

    2016-10-01

    Continued progress in chronic alcohol abuse investigation requires the development of less invasive procedures for screening purposes. The application of finger-prick and related dried blood spots (fpDBS) for carbohydrate deficient transferrin (CDT) detection appears suitable for this aim. Therefore, the goal of this project was to develop a screening method for CDT using fpDBS with CZE analysis. Blood samples prepared by finger-prick were placed on DBS cards and left to air dry; each dried fpDBS disc was shredded into small pieces and suspended in acid solution (60 μL of HCl 120 mmol/L). After centrifugation (10 min at 1500 × g), the collected sample was adjusted to pH 3.5. After an overnight incubation, the pH was neutralised and an iron rich solution was added. After 1 h, CZE analysis was carried out. A group of 47 individuals was studied. Parallel serum samples were collected from each investigated subject and the %CDT for each sample was measured using HPLC and CZE techniques. The fpDBS transferrin sialo isoform electropherograms were similar to those obtained with serum. Moreover, fpDBS CZE CDT percentage levels demonstrated significant statistical correlation with those obtained from serum for both HPLC and CZE %CDT (p < 0.01; r 2 = 0.8913 and 0.8976, respectively), with %CDT from 0.8 to 13.7% for fpDBS and from 0.7 to 12.7% for serum. The newly developed fpDBS procedure for CDT analysis provides a simple and inexpensive tool for use in population screening. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Oral cancer screening: serum Raman spectroscopic approach

    NASA Astrophysics Data System (ADS)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  9. Socioeconomic barriers to informed decisionmaking regarding maternal serum screening for down syndrome: results of the French National Perinatal Survey of 1998.

    PubMed

    Khoshnood, Babak; Blondel, Béatrice; de Vigan, Catherine; Bréart, Gérard

    2004-03-01

    We sought to evaluate socioeconomic disparities in serum screening for Down syndrome and assess whether such disparities are more likely to reflect limits in access or information or, rather, informed decisionmaking. A nationally representative sample of 12 869 French women completed interviews after giving birth. We found substantial disparities in the likelihood of (1) women not being offered screening, (2) screening not being offered as a result of late prenatal care, and (3) women not knowing whether or not they had undergone screening. Except in the case of nationality, there was essentially no evidence of differences in refusal of testing. Rather than representing informed decisionmaking, socioeconomic disparities in screening for Down syndrome are mostly due to limits in access or to information.

  10. Development and evaluation of an enzyme-labeled antibody test for the rapid detection of hog cholera antibodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, G.C.

    1977-01-01

    A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.

  11. A screening method for biotinidase deficiency in newborns.

    PubMed

    Heard, G S; Secor McVoy, J R; Wolf, B

    1984-01-01

    We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.

  12. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    PubMed

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  13. IL8 and IL16 levels indicate serum and plasma quality.

    PubMed

    Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay

    2018-02-09

    Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.

  14. Silver Nanoscale Hexagonal Column Chips for Detecting Cell-free DNA and Circulating Nucleosomes in Cancer Patients.

    PubMed

    Ito, Hiroaki; Hasegawa, Katsuyuki; Hasegawa, Yuuki; Nishimaki, Tadashi; Hosomichi, Kazuyoshi; Kimura, Satoshi; Ohba, Motoi; Yao, Hiroshi; Onimaru, Manabu; Inoue, Ituro; Inoue, Haruhiro

    2015-05-21

    Blood tests, which are commonly used for cancer screening, generally have low sensitivity. Here, we developed a novel rapid and simple method to generate silver nanoscale hexagonal columns (NHCs) for use in surface-enhanced Raman scattering (SERS). We reported that the intensity of SERS spectra of clinical serum samples obtained from gastrointestinal cancer patients is was significantly higher than that of SERS spectra of clinical serum samples obtained from non-cancer patients. We estimated the combined constituents on silver NHCs by using a field emission-type scanning electron microscope, Raman microscopes, and a 3D laser scanning confocal microscope. We obtained the Raman scattering spectra of samples of physically fractured cells and clinical serum. No spectra were obtained for chemically lysed cultured cells and DNA, RNA, and protein extracted from cultured cells. We believe that our method, which uses SERS with silver NHCs to detect circulating nucleosomes bound by methylated cell-free DNA, may be successfully implemented in blood tests for cancer screening.

  15. Serum Metabonomics of Mild Acute Pancreatitis.

    PubMed

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P < 0.05). Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  16. Based on surface-enhanced Raman spectroscopy analysis of serum albumin in different stages of liver disease for early screening primary liver cancer

    NASA Astrophysics Data System (ADS)

    Liao, Fadian; Ruan, Qiuyong; Lin, Juqiang; Lin, Jinyong; Zeng, Yongyi; Li, Ling; Huang, Zufang; Liu, Nenrong; Chen, Rong

    2014-09-01

    Despite the introduction of high-technology methods of detection and diagnosis, screening of primary liver cancer (PLC) remains imperfect. To diagnosis PLC earlier, Surface-enhanced Raman spectroscopy (SERS) coupled with cellulose-acetate membrane electrophoresis were introduced to separate human serum albumin and SERS spectra. Three groups (15 normal persons' samples, 17 hepatitis/cirrhosis samples, 15 cases of PLC) of serum albumin were tested. Silver colloid was used to obtain SERS spectra of human serum albumin. Principal component analysis (PCA) and linear discriminant analysis (LDA) were also employed for statistical analysis. The mean Raman spectra of three groups and the difference spectra of any two suggested that the albumin has changed in liver patients. Compared to normal groups, some Raman peaks have shifted or even disappeared in hepatitis/cirrhosis and PLCs groups. The sensitivity and specificity between PLCs and normal groups is 80% and 93.3%. Among hepatitis/cirrhosis and normal groups, the sensitivity is 88.2% and specificity is also 93.3%. Besides, the sensitivity and specificity between PLCs and hepatitis/cirrhosis groups is 86.7% and 76.5%. All the above data and results indicated that early screening of PLC is potential by SERS in different stages of liver disease before cancer occurs.

  17. Maternal biochemical serum screening for Down syndrome in pregnancy with human immunodeficiency virus infection.

    PubMed

    Le Meaux, Jean-Patrick; Tsatsaris, Vassilis; Schmitz, Thomas; Fulla, Yvonne; Launay, Odile; Goffinet, François; Azria, Elie

    2008-08-01

    To estimate the influence of human immunodeficiency virus (HIV) infection and antiretroviral therapy on maternal serum markers levels and the false-positive rate with biochemical maternal serum screening for Down syndrome. We performed a 1:1 matched case-control study comparing 132 HIV-infected women with single pregnancy to controls selected among non-HIV-infected women matched on geographical origin and fetal sex. Of HIV-infected women, 47.7% were receiving antiretroviral therapy. Groups did not differ in multiples of the median (MoM) levels of total human chorionic gonadotrophin. The MoM alpha fetoprotein level did not differ between total HIV-infected women and control women but was significantly lower for untreated HIV-positive women compared with control women (0.91 compared with 1.03 MoM, P<.01) and compared with treated HIV-positive women (0.91 compared with 1.18 MoM, P<.01). The false-positive rate of biochemical screening did not differ between groups. Untreated HIV infection is associated with lower maternal serum alpha fetoprotein levels. Nevertheless, the false-positive rate of double-marker second-trimester Down syndrome serum screening did not appear to be affected in our sample of HIV-infected women, whether women were receiving antiretroviral therapy at the time of the test or not.

  18. Antenatal screening for Down syndrome using serum placental growth factor with the combined, quadruple, serum integrated and integrated tests.

    PubMed

    Wald, Nicholas J; Bestwick, Jonathan P; George, Lynne M; Huttly, Wayne J

    2012-01-01

    To estimate the value of first or second trimester placental growth factor (PlGF) as an additional antenatal screening marker for Down syndrome. Nested case-control study. Antenatal screening service. 532 Down syndrome pregnancies and 1,155 matched unaffected pregnancies. Stored maternal serum samples (-40°C) were assayed for PlGF. Monte Carlo simulation was used to estimate the screening performance of PlGF with the Combined, Quadruple, serum Integrated and Integrated tests. Median PlGF levels in affected and unaffected pregnancies and screening performance (detection rates [DR] for specified false-positive rates [FPR] and vice versa). First trimester median PlGF was 15%, 28% and 39% lower in Down syndrome than unaffected pregnancies at 11, 12 and 13 completed weeks' gestation respectively (all p<0.001). Second trimester median PlGF was 31% lower at 14 weeks (p<0.001), and the difference decreased (6% lower at 17 weeks). At a 90% DR with first trimester markers measured at 13 weeks, adding PlGF decreased the FPR from 11.1 to 5.1% using the Combined test, 9.3% to 4.5% using the serum Integrated test, and 3.4% to 1.5% using the Integrated test (or 1.5 to 1.4% with first trimester markers measured at 11 weeks). Adding PlGF to the Quadruple test (measured at 15 weeks) decreased the FPR from 10.0% to 9.6% at a 90% DR. First trimester PlGF measurements improve the performance of antenatal screening for Down syndrome using the Combined, serum Integrated and Integrated tests. Second trimester PlGF measurements are of limited value.

  19. Development and evaluation of a recombinant-glycoprotein-based latex agglutination test for rabies virus antibody assessment.

    PubMed

    Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal

    2014-08-01

    The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.

  20. Multicenter Comparison of Serum and Whole-Blood Specimens for Detection of Aspergillus DNA in High-Risk Hematological Patients

    PubMed Central

    Springer, Jan; Morton, C. O.; Perry, Michael; Heinz, Werner J.; Paholcsek, Melinda; Alzheimer, Mona; Rogers, T. R.; Barnes, Rosemary A.; Einsele, Hermann; White, P. Lewis

    2013-01-01

    Samples from patients at high risk for invasive aspergillosis (IA) were prospectively collected and analyzed for the presence of molecular markers of fungal infection. Serum specimens were screened for galactomannan and Aspergillus DNA, and whole-blood specimens were screened only for Aspergillus DNA. Fungal infections were categorized according to the European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group, National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) criteria. Forty-seven cases (proven and probable IA) and 31 controls (no evidence of IA) were selected retrospectively for this case-control study, comprising 803 samples, in order to determine the performance of whole-blood PCR, serum PCR, and serum galactomannan testing. Although no single assay was able to detect every case of IA, a combination of different assays provided the best performance. There was no significant difference between the use of whole-blood and serum specimens for PCR-based diagnosis of IA, but there was a trend for whole blood to be more sensitive (85% versus 79%) and to yield an earlier positive result (36 days versus 15 days) than for serum. However, DNA extraction from serum specimens is easier and faster than that from whole-blood specimens, and it allows the same specimen to be used for both galactomannan and PCR assays. In conclusion, the appropriate sample type for DNA extraction should be determined by the local requirements and the technical platforms available at each individual center. A combination of biomarker tests offered the best diagnostic utility for detecting IA. PMID:23426930

  1. Multiplexed Analysis of Serum Breast and Ovarian Cancer Markers by Means of Suspension Bead-quantum Dot Microarrays

    NASA Astrophysics Data System (ADS)

    Brazhnik, Kristina; Sokolova, Zinaida; Baryshnikova, Maria; Bilan, Regina; Nabiev, Igor; Sukhanova, Alyona

    Multiplexed analysis of cancer markers is crucial for early tumor diagnosis and screening. We have designed lab-on-a-bead microarray for quantitative detection of three breast cancer markers in human serum. Quantum dots were used as bead-bound fluorescent tags for identifying each marker by means of flow cytometry. Antigen-specific beads reliably detected CA 15-3, CEA, and CA 125 in serum samples, providing clear discrimination between the samples with respect to the antigen levels. The novel microarray is advantageous over the routine single-analyte ones due to the simultaneous detection of various markers. Therefore the developed microarray is a promising tool for serum tumor marker profiling.

  2. A prospective clinical trial to compare the performance of dried blood spots prenatal screening for Down's syndrome with conventional non-invasive testing technology.

    PubMed

    Hu, Huiying; Jiang, Yulin; Zhang, Minghui; Liu, Shanying; Hao, Na; Zhou, Jing; Liu, Juntao; Zhang, Xiaojin; Ma, Liangkun

    2017-03-01

    To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down's syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down's syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down's syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down's syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a "before and after" two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down's syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down's syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down's syndrome and to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. Results demonstrate that fetal cfDNA can significantly reduce false-positive rate close to none while distinguishing all true positives. Thus, we recommend that fetal cfDNA analysis to be utilized as a secondary screening tool atop of the primary blood protein screening to further minimize the capacity of undesirable invasive diagnostic operations.

  3. [Antenatal diagnosis: the revolution of new technologies].

    PubMed

    Fokstuen, Siv; Sloan-Béna, Frédérique; lrion, Olivier

    2014-01-15

    Since ten years, the number of amniocenteses or chorionic villous sampling for maternal anxiety has decreased thanks to the first trimester screening of trisomy 21 by ultrasound and maternal serum analysis. Two new tools have recently revolutionized antenatal screening and diagnosis: Analysing fetal DNA in maternal blood for chromosomes 21, 18 and 13 in order to avoid invasive fetal sampling and genomic comparative hybridization in order to diagnose deletions or duplications not detected by conventional caryotyping. These new technologies are dedicated to high-risk pregnancies, and have limitations. They do not replace ultrasound or first trimester screening. Information and ethics are central in antenatal screening and diagnosis.

  4. Exploring the concurrent presence of hepatitis A virus genome in serum, stool, saliva, and urine samples of hepatitis A patients.

    PubMed

    Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D

    2014-04-01

    The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Sero-prevalence of bovine Johne's disease in buffaloes and cattle population of North India using indigenous ELISA kit based on native Mycobacterium avium subspecies paratuberculosis 'Bison type' genotype of goat origin.

    PubMed

    Singh, S V; Singh, A V; Singh, R; Sharma, S; Shukla, N; Misra, S; Singh, P K; Sohal, J S; Kumar, H; Patil, P K; Misra, P; Sandhu, K S

    2008-09-01

    Present pilot study is the first attempt in the country to estimate sero-prevalence of Bovine Johne's disease (BJD) by screening cattle and buffaloes representing large population belonging to farmer's and farm herds in the home tracts (Uttar Pradesh (UP) and Punjab) of Hariana cattle and Murrah buffaloes in North India. Indigenous and in-house plate ELISA kit (using protoplasmic antigen from native Mycobacterium avium subsp. paratuberculosis 'Bison type' strain of goat origin), originally developed for goats and sheep was standardized in bovines and used for screening. For this study, 33 villages of south and west UP were randomly selected and surveyed from 2001 to 2003. There were 7943 farmer's families having 38,251 livestock, including cattle, buffaloes, goats and sheep (per family 4.8% livestock). Numerically, buffaloes and cattle were 54.7% and 22.1%, respectively. Serum samples were collected from 726 animals (4.2% of 16, 981 livestock with 4375 farmer's families) located in 33 randomly surveyed villages. Serum samples (699), submitted to Epidemiology Department of Veterinary College (Punjab Agricultural University, Ludhiana), in the year 2004 by farmer's and organized farm herds (Buffaloes, 372, Cattle, 327), were screened by this ELISA kit. Soluble protoplasmic antigen was prepared from Map (S 5) 'Bison type' strain isolated from a terminally sick goat with Johne's disease. Of the total 1425 bovine (Buffaloes and cattle) serum samples screened using indigenous ELISA kit, sero-prevalence of Johne's disease was 29.0% (28.6% in buffalo and 29.8% in cattle) in Northern India. State-wise sero-prevalence was 31.9% and 23.3% in UP and Punjab, respectively. In UP, of the 601 randomly sampled buffaloes, sero-prevalence was 40.3% (16.6% in young and 40.9% adults) and 25.5% (10.5% in young and 26.3% adults) in south and west UP, respectively. Of the 125 cattle screened, sero-prevalence was 42.6% (nil in young and 44.4% adults) and 30.0% (nil in young and 30.6% adults) in south and west UP, respectively. Of the 699 serum samples screened from Ludhiana, Punjab, sero-prevalence of BJD was 23.0%. Sero-prevalence was 23.3% (12.1% in young and 24.4% in adults) and 26.9% (27.2% in young and 26.8% in adults) in buffaloes and cattle, respectively. High prevalence of BJD in buffaloes in native tract of Murrah breed, and Hariana breed of cattle correlated with poor per-animal productivity and BJD may be the major cause. Indigenous ELISA kit was rapid, economic and sensitive test for large-scale screening of buffaloes and cattle population against incurable BJD.

  6. Development of Glycoprotein Capture-Based Label-Free Method for the High-throughput Screening of Differential Glycoproteins in Hepatocellular Carcinoma*

    PubMed Central

    Chen, Rui; Tan, Yexiong; Wang, Min; Wang, Fangjun; Yao, Zhenzhen; Dong, Liwei; Ye, Mingliang; Wang, Hongyang; Zou, Hanfa

    2011-01-01

    A robust, reproducible, and high throughput method was developed for the relative quantitative analysis of glycoprotein abundances in human serum. Instead of quantifying glycoproteins by glycopeptides in conventional quantitative glycoproteomics, glycoproteins were quantified by nonglycosylated peptides derived from the glycoprotein digest, which consists of the capture of glycoproteins in serum samples and the release of nonglycopeptides by trypsin digestion of captured glycoproteins followed by two-dimensional liquid chromatography-tandem MS analysis of released peptides. Protein quantification was achieved by comparing the spectrum counts of identified nonglycosylated peptides of glycoproteins between different samples. This method was demonstrated to have almost the same specificity and sensitivity in glycoproteins quantification as capture at glycopeptides level. The differential abundance of proteins present at as low as nanogram per milliliter levels was quantified with high confidence. The established method was applied to the analysis of human serum samples from healthy people and patients with hepatocellular carcinoma (HCC) to screen differential glycoproteins in HCC. Thirty eight glycoproteins were found with substantial concentration changes between normal and HCC serum samples, including α-fetoprotein, the only clinically used marker for HCC diagnosis. The abundance changes of three glycoproteins, i.e. galectin-3 binding protein, insulin-like growth factor binding protein 3, and thrombospondin 1, which were associated with the development of HCC, were further confirmed by enzyme-linked immunosorbent assay. In conclusion, the developed method was an effective approach to quantitatively analyze glycoproteins in human serum and could be further applied in the biomarker discovery for HCC and other cancers. PMID:21474793

  7. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  8. A comprehensive library-based, automated screening procedure for 46 synthetic cannabinoids in serum employing liquid chromatography-quadrupole ion trap mass spectrometry with high-temperature electrospray ionization.

    PubMed

    Huppertz, Laura M; Kneisel, Stefan; Auwärter, Volker; Kempf, Jürgen

    2014-02-01

    Considering the vast variety of synthetic cannabinoids and herbal mixtures - commonly known as 'Spice' or 'K2' - on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up-to-date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography-ion trap-MS (LC-MS(n)) system and a spectra library-based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high-temperature ESI source (IonBooster(TM), Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high-temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS(2)/MS(3) spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut-off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster-source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Isolation and characterization of a novel cervid adenovirus from white-tailed deer (Odocoileus virginianus) fawns in a captive herd

    USDA-ARS?s Scientific Manuscript database

    A novel adenovirus was isolated from buffy coat and serum samples from two captive white-tailed deer (Odocoileus virginianus) fawns. The isolation was incidental finding in the course of screening animals for use in a research study on an unrelated pathogen. In the screening process, virus isolati...

  10. A blood-based screening tool for Alzheimer's disease that spans serum and plasma: findings from TARC and ADNI.

    PubMed

    O'Bryant, Sid E; Xiao, Guanghua; Barber, Robert; Huebinger, Ryan; Wilhelmsen, Kirk; Edwards, Melissa; Graff-Radford, Neill; Doody, Rachelle; Diaz-Arrastia, Ramon

    2011-01-01

    There is no rapid and cost effective tool that can be implemented as a front-line screening tool for Alzheimer's disease (AD) at the population level. To generate and cross-validate a blood-based screener for AD that yields acceptable accuracy across both serum and plasma. Analysis of serum biomarker proteins were conducted on 197 Alzheimer's disease (AD) participants and 199 control participants from the Texas Alzheimer's Research Consortium (TARC) with further analysis conducted on plasma proteins from 112 AD and 52 control participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The full algorithm was derived from a biomarker risk score, clinical lab (glucose, triglycerides, total cholesterol, homocysteine), and demographic (age, gender, education, APOE*E4 status) data. Alzheimer's disease. 11 proteins met our criteria and were utilized for the biomarker risk score. The random forest (RF) biomarker risk score from the TARC serum samples (training set) yielded adequate accuracy in the ADNI plasma sample (training set) (AUC = 0.70, sensitivity (SN) = 0.54 and specificity (SP) = 0.78), which was below that obtained from ADNI cerebral spinal fluid (CSF) analyses (t-tau/Aβ ratio AUC = 0.92). However, the full algorithm yielded excellent accuracy (AUC = 0.88, SN = 0.75, and SP = 0.91). The likelihood ratio of having AD based on a positive test finding (LR+) = 7.03 (SE = 1.17; 95% CI = 4.49-14.47), the likelihood ratio of not having AD based on the algorithm (LR-) = 3.55 (SE = 1.15; 2.22-5.71), and the odds ratio of AD were calculated in the ADNI cohort (OR) = 28.70 (1.55; 95% CI = 11.86-69.47). It is possible to create a blood-based screening algorithm that works across both serum and plasma that provides a comparable screening accuracy to that obtained from CSF analyses.

  11. Diagnostic value of protein chips constructed by lung-cancer-associated markers selected by the T7 phage display library.

    PubMed

    Li, Hong-Mei; Guo, Kang; Yu, Zhuang; Feng, Rui; Xu, Ping

    2015-07-01

    Traditional diagnostic technology with tumor biomarkers is inefficient, expensive and requires a large number of serum samples. The purpose of this study was to construct human lung cancer protein chips with new lung cancer biomarkers screened by the T7-phage display library, and improve the early diagnosis rate of lung cancer. A T7-phage cDNA display library was constructed of fresh samples from 30 lung cancer patients. With biopanning and high-throughput screening, we gained the immunogenic phage clones from the cDNA library. The insert of selected phage was blasted at GeneBank for alignment to find the exact or the most similar known genes. Protein chips were then constructed and used to assay their expression level in lung cancer serum from 217 cases of lung cancer groups:80 cases of benign lung disease and 220 healthy controls. After four rounds of Biopanning and two rounds of enzyme-linked immunosorbent assay, 12 phage monoclonal samples were selected from 2880 phage monoclonal samples. After blasting at GeneBank, six similar genes were used to construct diagnostic protein chips. The protein chips were then used to assay expression level in lung cancer serum. The expression level of six genes in lung cancer groups was significantly higher than those in the other two groups (P < 0.05). In this study, we successfully constructed diagnostic protein chips with biomarkers selected from the lung cancer T7-phage cDNA library, which can be used for the early screening of lung cancer patients.

  12. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  13. Real-time analysis of dual-display phage immobilization and autoantibody screening using quartz crystal microbalance with dissipation monitoring.

    PubMed

    Rajaram, Kaushik; Losada-Pérez, Patricia; Vermeeren, Veronique; Hosseinkhani, Baharak; Wagner, Patrick; Somers, Veerle; Michiels, Luc

    2015-01-01

    Over the last three decades, phage display technology has been used for the display of target-specific biomarkers, peptides, antibodies, etc. Phage display-based assays are mostly limited to the phage ELISA, which is notorious for its high background signal and laborious methodology. These problems have been recently overcome by designing a dual-display phage with two different end functionalities, namely, streptavidin (STV)-binding protein at one end and a rheumatoid arthritis-specific autoantigenic target at the other end. Using this dual-display phage, a much higher sensitivity in screening specificities of autoantibodies in complex serum sample has been detected compared to single-display phage system on phage ELISA. Herein, we aimed to develop a novel, rapid, and sensitive dual-display phage to detect autoantibodies presence in serum samples using quartz crystal microbalance with dissipation monitoring as a sensing platform. The vertical functionalization of the phage over the STV-modified surfaces resulted in clear frequency and dissipation shifts revealing a well-defined viscoelastic signature. Screening for autoantibodies using antihuman IgG-modified surfaces and the dual-display phage with STV magnetic bead complexes allowed to isolate the target entities from complex mixtures and to achieve a large response as compared to negative control samples. This novel dual-display strategy can be a potential alternative to the time consuming phage ELISA protocols for the qualitative analysis of serum autoantibodies and can be taken as a departure point to ultimately achieve a point of care diagnostic system.

  14. Development and application of molecularly imprinted polymer - Mn-doped ZnS quantum dot fluorescent optosensing for cocaine screening in oral fluid and serum.

    PubMed

    Chantada-Vázquez, María Pilar; de-Becerra-Sánchez, Carolina; Fernández-Del-Río, Alba; Sánchez-González, Juan; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2018-05-01

    A molecularly imprinted polymer - Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL -1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL -1 and 0.117mgL -1, respectively; whereas, 0.015mgL -1 (LOD) and 0.050mgL -1 (LOQ) were obtained for serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Weak cation magnetic separation technology and MALDI-TOF-MS in screening serum protein markers in primary type I osteoporosis.

    PubMed

    Shi, X L; Li, C W; Liang, B C; He, K H; Li, X Y

    2015-11-30

    We investigated weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of primary type I osteoporosis. We selected 16 postmenopausal women with osteoporosis and nine postmenopausal women as controls to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were obtained from controls and patients. Serum protein was extracted with the WCX protein chip system; protein fingerprints were examined using MALDI-TOF-MS. The preprocessed and model construction data were handled by the ProteinChip system. The diagnostic models were established using a genetic arithmetic model combined with a support vector machine (SVM). The SVM model with the highest Youden index was selected. Combinations with the highest accuracy in distinguishing different groups of data were selected as potential biomarkers. From the two groups of serum proteins, 123 cumulative MS protein peaks were selected. Significant intensity differences in the protein peaks of 16 postmenopausal women with osteoporosis were screened. The difference in Youden index between the four groups of protein peaks showed that the highest peaks had mass-to-charge ratios of 8909.047, 8690.658, 13745.48, and 15114.52. A diagnosis model was established with these four markers as the candidates, and the model specificity and sensitivity were found to be 100%. Two groups of specimens in the SVM results on the scatterplot were distinguishable. We established a diagnosis model, and provided a new serological method for screening and diagnosis of osteoporosis with high sensitivity and specificity.

  16. Apolipoprotein C-II Is a Potential Serum Biomarker as a Prognostic Factor of Locally Advanced Cervical Cancer After Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harima, Yoko, E-mail: harima@takii.kmu.ac.jp; Ikeda, Koshi; Utsunomiya, Keita

    Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in themore » validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC.« less

  17. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  18. Screening and staging for non-small cell lung cancer by serum laser Raman spectroscopy.

    PubMed

    Wang, Hong; Zhang, Shaohong; Wan, Limei; Sun, Hong; Tan, Jie; Su, Qiucheng

    2018-08-05

    Lung cancer is the leading cause of cancer-related death worldwide. Current clinical screening methods to detect lung cancer are expensive and associated with many complications. Raman spectroscopy is a spectroscopic technique that offers a convenient method to gain molecular information about biological samples. In this study, we measured the serum Raman spectral intensity of healthy volunteers and patients with different stages of non-small cell lung cancer. The purpose of this study was to evaluate the application of serum laser Raman spectroscopy as a low cost alternative method in the screening and staging of non-small cell lung cancer (NSCLC). The Raman spectra of the sera of peripheral venous blood were measured with a LabRAM HR 800 confocal Micro Raman spectrometer for individuals from five groups including 14 healthy volunteers (control group), 23 patients with stage I NSCLC (stage I group), 24 patients with stage II NSCLC (stage II group), 19 patients with stage III NSCLC (stage III group), 11 patients with stage IV NSCLC (stage IV group). Each serum sample was measured 3 times at different spots and the average spectra represented the signal of Raman spectra in each case. The Raman spectrum signal data of the five groups were statistically analyzed by analysis of variance (ANOVA), principal component analysis (PCA), linear discriminant analysis (LDA), and cross-validation. Raman spectral intensity was sequentially reduced in serum samples from control group, stage I group, stage II group and stage III/IV group. The strongest peak intensity was observed in the control group, and the weakest one was found in the stage III/IV group at bands of 848 cm -1 , 999 cm -1 , 1152 cm -1 , 1446 cm -1 and 1658 cm -1 (P < 0.05). Linear discriminant analysis showed that the sensitivity to identify healthy people, stage I, stage II, and stage III/IV NSCLC was 86%, 65%, 75%, and 87%, respectively; the specificity was 95%, 94%, 88%, and 93%, respectively; and the overall accuracy rate was 92% (71/77). The laser Raman spectroscopy can effectively identify patients with stage I, stage II or stage III/IV Non-Small Cell Lung cancer using patient serum samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. EDRN Breast and Ovary Cancer CVC, Study 3: Phase 3 Validation of screening decision rules in preclinical UKCTOCS serial samples — EDRN Public Portal

    Cancer.gov

    We will collaborate with investigators from University College London to test a screening decision rule in preclinical serial samples from the U.K. Collaborative Trial of Ovarian Cancer Screening (UKCTOCS) to learn if the panel can do better than CA125 alone. The UKCTOCS is an ideal setting for retrospective validation of an early detection marker panel and decision rule because it offers serial samples collected annually and use of imaging in women with rising CA125. Multi-modal strategies using serum markers HE4, MSLN, MMP7, and CA125 will be compared to strategies relying exclusively on CA125 and transvaginal sonography (TVS).

  20. [Screening and identification of apolipoprotein A-I as a potential marker for hepatoblastoma in children].

    PubMed

    Guo, Li-Hua; Zhao, Wei; Zhang, Jun-Jie; Zhang, Qian; Fan, Ying-Zhong; Wang, Jia-Xiang

    2016-12-01

    To screen and identify serum biomarkers for childhood hepatoblastoma (HB). The serum samples from 30 children with hepatoblastoma (HB), 20 children with systemic inflammatory response syndrome, and 20 normal children were treated with magnetic bead-based weak cation exchange chromatography. The platform of surface-enhanced laser desorption/ionization-time of flight-mass spectrometry (SELDI-TOF-MS) was used to eliminate the interference of inflammatory factors and to screen out the differentially expressed proteins in serum between tumor group and normal group. After the purification and separation of target proteins were performed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis, matrix-assisted laser desorption/ionization-time of flight-mass spectrometry was used to determine their amino acid sequences. The SwissProt database was searched for matched proteins. Finally, real-time PCR and ELISA were used to verify and measure the expression of target proteins. After SELDI-TOF-MS was used for screening and elimination of the interference of inflammatory factors, a differentially expression protein with a mass-to-charge ratio of 9 348 Da was found in serum between HB group and normal group, and the HB group had significantly lower expression of this protein than the normal group (p<0.05). This protein was identified as apolipoprotein A-1 (Apo A-I). Real-time PCR and ELISA verified the low mRNA and protein expression of Apo A-I in serum in the HB group and high expression in serum in the normal group. Apo A-I can be used as a non-inflammatory protein marker for HB and has a certain value in the early diagnosis of HB.

  1. Bluetongue virus surveillance in the Islamic Republic of Mauritania: Is serotype 26 circulating among cattle and dromedaries?

    PubMed

    Lorusso, Alessio; Baba, Doumbia; Spedicato, Massimo; Teodori, Liana; Bonfini, Barbara; Marcacci, Maurilia; Di Provvido, Andrea; Isselmou, Katia; Marini, Valeria; Carmine, Irene; Scacchia, Massimo; Di Sabatino, Daria; Petrini, Antonio; Bezeid, Beyatt Ahmed; Savini, Giovanni

    2016-06-01

    In March 2013, EDTA-blood and serum samples were collected from 119 cattle and 159 dromedaries at the slaughterhouse of Nouakchott, the capital city of the Islamic Republic of Mauritania. Serum samples were screened for the presence of Bluetongue (BT) antibodies by competitive ELISA (cELISA). Positive samples were then tested by serum-neutralization (SN) to determine BTV serotype. RNA from blood samples was first tested by a genus-specific quantitative RT-PCR assay which is able to detect all 27 existing BTV serotypes (RT-qPCR1-27). Positive samples were further screened by a RT-qPCR assay which, instead, is able to detect the classical 24 BTV serotypes only (RT-qPCR1-24). Of the 278 serum samples tested, 177 (mean=63.7%; 95% CI: 57.9%-69.1%) resulted positive by cELISA. Of these, 69 were from cattle (mean=58.0%; 95% CI: 49.0%-66.5%) and 108 from dromedaries (mean=67.9%; 95% CI: 60.3%-74.7%). BTV-26 neutralizing antibodies were by far the most frequently found as they were detected in 146 animals with titres ranging from 1:10 to 1:80. Out of 278 blood samples, 25 (mean=9.0%; 95% CI: 6.2%-12.9%) were found positive for BTV by RT-qPCR1-27, 20 (mean=16.8%; 95% CI: 11.2%-24.6%) were from cattle and 5 (mean=3.1%; 95% CI: 1.4%-7.1%) from dromedaries. When tested by RT-qPCR1-24 the 25 BTV positive samples were negative. Unfortunately, no genetic information by molecular typing or by next generation sequencing has been obtained as for the very low levels of RNA in the blood samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    PubMed

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  3. Serologic Evidence of Fruit Bat Exposure to Filoviruses, Singapore, 2011-2016.

    PubMed

    Laing, Eric D; Mendenhall, Ian H; Linster, Martin; Low, Dolyce H W; Chen, Yihui; Yan, Lianying; Sterling, Spencer L; Borthwick, Sophie; Neves, Erica Sena; Lim, Julia S L; Skiles, Maggie; Lee, Benjamin P Y-H; Wang, Lin-Fa; Broder, Christopher C; Smith, Gavin J D

    2018-01-01

    To determine whether fruit bats in Singapore have been exposed to filoviruses, we screened 409 serum samples from bats of 3 species by using a multiplex assay that detects antibodies against filoviruses. Positive samples reacted with glycoproteins from Bundibugyo, Ebola, and Sudan viruses, indicating filovirus circulation among bats in Southeast Asia.

  4. Co-infections with Chikungunya and Dengue Viruses, Guatemala, 2015.

    PubMed

    Edwards, Thomas; Signor, Leticia Del Carmen Castillo; Williams, Christopher; Donis, Evelin; Cuevas, Luis E; Adams, Emily R

    2016-11-01

    We screened serum samples referred to the national reference laboratory in Guatemala that were positive for chikungunya or dengue viruses in June 2015. Co-infection with both viruses was detected by reverse transcription PCR in 46 (32%) of 144 samples. Specimens should be tested for both arboviruses to detect co-infections.

  5. Seroprevalence of human T cell leukaemia/lymphoma virus type I (HTLV-I) in pregnant women, patients attending venereological outpatient services and intravenous drug users from Slovenia.

    PubMed

    Poljak, M; Bednarik, J; Rednak, K; Seme, K; Kristancic, L; Celan-Lucu, B

    1998-01-01

    To establish current seroprevalence of human T cell leukaemia/lymphoma virus type I (HTLV-I) infection in some low- and high-risk populations from Slovenia, 10,369 and 869 serum samples collected during Slovenian 1994 unlinked surveys of human immunodeficiency viruses seroprevalence in pregnant women and patients attending venereological outpatient services, respectively, and 219 serum samples collected from Slovenian intravenous drug abusers during 1995 and 1996, were screened for the presence of anti-HTLV-I antibodies using commercial particle agglutination test Serodia HTLV-I (Fujirebio, Tokyo, Japan). Only one sample obtained from a pregnant woman was found repeatedly positive in the screening test. Presence of anti-HTLV-I antibodies in the reactive sample was undoubtedly confirmed with supplemental Western blot test. The prevalence of antibodies to HTLV-I in the Slovenian population might be somewhere between one in 10,000 (0.01%) and one in 15,000 (0.0066%), which is similar or even higher to prevalence rates in other European countries.

  6. Evaluation of the use of pooled serum, pooled muscle tissue fluid (meat juice) and pooled faeces for monitoring pig herds for Salmonella.

    PubMed

    Davies, R H; Heath, P J; Coxon, S M; Sayers, A R

    2003-01-01

    Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.

  7. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  8. First-Trimester Maternal Serum Amino Acids and Acylcarnitines Are Significant Predictors of Gestational Diabetes

    PubMed Central

    Nevalainen, Jaana; Sairanen, Mikko; Appelblom, Heidi; Gissler, Mika; Timonen, Susanna; Ryynänen, Markku

    2016-01-01

    BACKGROUND: Current screening methods for gestational diabetes mellitus (GDM) are insufficient in detecting the risk of GDM in the first trimester of the pregnancy. Recent metabolomic studies have detected altered amino acid and acylcarnitine concentrations in type 2 diabetes (T2D). Because of the similarities between T2D and GDM, the determination of these metabolites may be useful in early screening for GDM. AIM: To evaluate the association between GDM and first-trimester maternal serum concentrations of ten amino acids and 31 acylcarnitines. METHODS: This retrospective case-control study included data from pregnant women screened at Oulu University Hospital between 1.1.2008 and 31.12.2011. A total of 31,146 women participated voluntarily in a first-trimester combined screening (for chromosomal abnormalities). The study population included 69 women who developed GDM during pregnancy and 295 women without diabetes before or after pregnancy. The serum concentrations of ten amino acids and 31 acylcarnitines were analyzed from frozen serum samples taken in the first-trimester screening. Multiple of median (MoM) values were compared between the two groups. RESULTS: In the GDM group, serum levels of arginine were significantly higher (1.13 MoM vs. 0.97 MoM), and those of glycine (0.93 MoM vs. 1.03 MoM) and 3-hydroxy-isovalerylcarnitine (0.86 MoM vs. 1.03 MoM) significantly lower compared to the control group (all p < 0.01). In each case, arginine, glycine, and 3-hydroxy-isovaleryl-carnitine would have detected 46%, 32%, and 39% of GDM cases, with a false-positive rate of 20%. Combining these three metabolites with the first-trimester serum marker pregnancy-associated plasma protein A (PAPP-A) and prior risk (age, BMI, and smoking) achieved a detection rate of 72%. CONCLUSION: There are significant differences in the serum levels of arginine, glycine, and 3-hydroxy-isovalerylcarnitine between controls and women who subsequently develop GDM. These differences were already existent in the first trimester of the pregnancy. The use of metabolites in combination with prior risk and first-trimester PAPP-A represents a reliable method to identify women at risk of GDM. PMID:28278310

  9. Serum galactomannan screening for diagnosis of invasive pulmonary aspergillosis in children after stem cell transplantation or with high-risk leukemia.

    PubMed

    Gefen, Aharon; Zaidman, Irina; Shachor-Meyouhas, Yael; Avidor, Israela; Hakim, Fahed; Weyl Ben-Arush, Myriam; Kassis, Imad

    2015-03-01

    Both transplanted and leukemia patients are at high risk (HR) for invasive pulmonary aspergillosis (IPA). Methods for rapid diagnosis are crucial. Our objective was to investigate the impact of serial serum galactomannan assay (GMA) screening on IPA diagnosis in children. Between January 2010 and December 2011, all children following stem cell transplantation (SCT) or with HR leukemia were prospectively included. Serum samples for GMA were taken once-twice weekly. Results >.5 were considered positive. Patients suspected of having IPA were stratified as possible, probable, and definite. Forty-six children (median age, 8 years) were included, 38 after SCT (32 allogeneic), 8 with HR leukemia. A total of 510 samples were taken; screening period was 1-6 months for 34 patients. GMA was negative in 28 patients, all but one without suspicion of IPA. Eighteen patients had positive GMA: while four (22%) were upgraded to probable IPA, fourteen (78%) were considered as false positives (FP), some associated with piperacillin-tazobactam treatment. GMA sensitivity and specificity were 0.8 and 0.66, respectively; positive- and negative-predictive values (PPV, NPV) were 0.22 and 0.96, respectively. GMA may have a role in evaluating HR children for IPA. Both NPV and FP rates are high. The cost benefit of early detection versus over-diagnosis should be further studied.

  10. IMMUNOCHEMICAL DETERMINATION OF DIOXINS IN SEDIMENT AND SERUM SAMPLES

    EPA Science Inventory

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the gro...

  11. Sensitivity and Specificity of an Operon Immunochromatographic Test in Serum and Whole-Blood Samples for the Diagnosis of Trypanosoma cruzi Infection in Spain, an Area of Nonendemicity

    PubMed Central

    Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio

    2012-01-01

    Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296

  12. Serum chemerin level during the first trimester of pregnancy and the risk of gestational diabetes mellitus.

    PubMed

    Yang, Xuezhou; Quan, Xiaozhen; Lan, Yanli; Ye, Jinhai; Wei, Qipeng; Yin, Xiaofang; Fan, Fangfang; Xing, Hui

    2017-10-01

    To investigate the association between chemerin level in the first trimester of pregnancy and the risk of gestational diabetes mellitus. The blood samples of 212 women at 8-12 weeks of gestation were collected. After screening for gestational diabetes mellitus (GDM), 19 women with GDM and 20 women randomly selected from 144 women with normal glucose tolerance (NGT) were included in the study. Blood samples were collected from these women. Triglycerides, glucose, total cholesterol, and HDL cholesterol, LDL cholesterol, insulin and chemerin were measured. Gestational weight gain and body mass index was assessed. Serum levels of chemerin were significantly elevated during late gestation, and the risk of GDM was positively associated with maternal serum chemerin in the first trimester. Serum chemerin level during the first trimester of pregnancy has the potential to predict risk of GDM.

  13. Serologic Evidence of Fruit Bat Exposure to Filoviruses, Singapore, 2011–2016

    PubMed Central

    Laing, Eric D.; Mendenhall, Ian H.; Linster, Martin; Low, Dolyce H. W.; Chen, Yihui; Yan, Lianying; Sterling, Spencer L.; Borthwick, Sophie; Neves, Erica Sena; Lim, Julia S. L.; Skiles, Maggie; Lee, Benjamin P. Y.-H.; Wang, Lin-Fa; Broder, Christopher C.

    2018-01-01

    To determine whether fruit bats in Singapore have been exposed to filoviruses, we screened 409 serum samples from bats of 3 species by using a multiplex assay that detects antibodies against filoviruses. Positive samples reacted with glycoproteins from Bundibugyo, Ebola, and Sudan viruses, indicating filovirus circulation among bats in Southeast Asia. PMID:29260678

  14. Clinical Performance of Aspergillus PCR for Testing Serum and Plasma: a Study by the European Aspergillus PCR Initiative.

    PubMed

    White, P Lewis; Barnes, Rosemary A; Springer, Jan; Klingspor, Lena; Cuenca-Estrella, Manuel; Morton, C Oliver; Lagrou, Katrien; Bretagne, Stéphane; Melchers, Willem J G; Mengoli, Carlo; Donnelly, J Peter; Heinz, Werner J; Loeffler, Juergen

    2015-09-01

    Aspergillus PCR testing of serum provides technical simplicity but with potentially reduced sensitivity compared to whole-blood testing. With diseases for which screening to exclude disease represents an optimal strategy, sensitivity is paramount. The associated analytical study confirmed that DNA concentrations were greater in plasma than those in serum. The aim of the current investigation was to confirm analytical findings by comparing the performance of Aspergillus PCR testing of plasma and serum in the clinical setting. Standardized Aspergillus PCR was performed on plasma and serum samples concurrently obtained from hematology patients in a multicenter retrospective anonymous case-control study, with cases diagnosed according to European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (19 proven/probable cases and 42 controls). Clinical performance and clinical utility (time to positivity) were calculated for both kinds of samples. The sensitivity and specificity for Aspergillus PCR when testing serum were 68.4% and 76.2%, respectively, and for plasma, they were 94.7% and 83.3%, respectively. Eighty-five percent of serum and plasma PCR results were concordant. On average, plasma PCR was positive 16.8 days before diagnosis and was the earliest indicator of infection in 13 cases, combined with other biomarkers in five cases. On average, serum PCR was positive 10.8 days before diagnosis and was the earliest indicator of infection in six cases, combined with other biomarkers in three cases. These results confirm the analytical finding that the sensitivity of Aspergillus PCR using plasma is superior to that using serum. PCR positivity occurs earlier when testing plasma and provides sufficient sensitivity for the screening of invasive aspergillosis while maintaining methodological simplicity. Copyright © 2015 White et al.

  15. Correlation of serum IgG concentration in foals and refractometry index of the dam's pre- and post-parturient colostrums: an assessment for failure of passive transfer in foals.

    PubMed

    Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Nambo, Yasuo

    2012-11-01

    The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial immunodiffusion (SRID) test (98 samples) and total protein concentration using a temperature-compensating refractometer (98 samples). Colostrum and milk samples were analyzed for refractometry index (RI) using a Brix refractometer (71 samples). DVSTP concentration and DVRI were significantly correlated with serum IgG concentration. The negative predictive values (NPVs) of DVSTP concentration for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 98.2% and 91.3% when the cutoff value is set to 0.4 mg/dl and 0.8 mg/dl, respectively. Furthermore, the NPVs of DVRI for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 97.3% and 96.3% when the cutoff value is set to 6% and 10%, respectively. The results suggest that measurement of DVRI is useful in assessing FPT as an initial "stall-side" screening test, because it is easy, inexpensive to perform and allows for rapid interpretation.

  16. Serum Autoantibodies in Chronic Prostate Inflammation in Prostate Cancer Patients.

    PubMed

    Schlick, Bettina; Massoner, Petra; Lueking, Angelika; Charoentong, Pornpimol; Blattner, Mirjam; Schaefer, Georg; Marquart, Klaus; Theek, Carmen; Amersdorfer, Peter; Zielinski, Dirk; Kirchner, Matthias; Trajanoski, Zlatko; Rubin, Mark A; Müllner, Stefan; Schulz-Knappe, Peter; Klocker, Helmut

    2016-01-01

    Chronic inflammation is frequently observed on histological analysis of malignant and non-malignant prostate specimens. It is a suspected supporting factor for prostate diseases and their progression and a main cause of false positive PSA tests in cancer screening. We hypothesized that inflammation induces autoantibodies, which may be useful biomarkers. We aimed to identify and validate prostate inflammation associated serum autoantibodies in prostate cancer patients and evaluate the expression of corresponding autoantigens. Radical prostatectomy specimens of prostate cancer patients (N = 70) were classified into high and low inflammation groups according to the amount of tissue infiltrating lymphocytes. The corresponding pre-surgery blood serum samples were scrutinized for autoantibodies using a low-density protein array. Selected autoantigens were identified in prostate tissue and their expression pattern analyzed by immunohistochemistry and qPCR. The identified autoantibody profile was cross-checked in an independent sample set (N = 63) using the Luminex-bead protein array technology. Protein array screening identified 165 autoantibodies differentially abundant in the serum of high compared to low inflammation patients. The expression pattern of three corresponding antigens were established in benign and cancer tissue by immunohistochemistry and qPCR: SPAST (Spastin), STX18 (Syntaxin 18) and SPOP (speckle-type POZ protein). Of these, SPAST was significantly increased in prostate tissue with high inflammation. All three autoantigens were differentially expressed in primary and/or castration resistant prostate tumors when analyzed in an inflammation-independent tissue microarray. Cross-validation of the inflammation autoantibody profile on an independent sample set using a Luminex-bead protein array, retrieved 51 of the significantly discriminating autoantibodies. Three autoantibodies were significantly upregulated in both screens, MUT, RAB11B and CSRP2 (p>0.05), two, SPOP and ZNF671, close to statistical significance (p = 0.051 and 0.076). We provide evidence of an inflammation-specific autoantibody profile and confirm the expression of corresponding autoantigens in prostate tissue. This supports evaluation of autoantibodies as non-invasive markers for prostate inflammation.

  17. Serum Autoantibodies in Chronic Prostate Inflammation in Prostate Cancer Patients

    PubMed Central

    Schlick, Bettina; Massoner, Petra; Lueking, Angelika; Charoentong, Pornpimol; Blattner, Mirjam; Schaefer, Georg; Marquart, Klaus; Theek, Carmen; Amersdorfer, Peter; Zielinski, Dirk; Kirchner, Matthias; Trajanoski, Zlatko; Rubin, Mark A.; Müllner, Stefan; Schulz-Knappe, Peter; Klocker, Helmut

    2016-01-01

    Background Chronic inflammation is frequently observed on histological analysis of malignant and non-malignant prostate specimens. It is a suspected supporting factor for prostate diseases and their progression and a main cause of false positive PSA tests in cancer screening. We hypothesized that inflammation induces autoantibodies, which may be useful biomarkers. We aimed to identify and validate prostate inflammation associated serum autoantibodies in prostate cancer patients and evaluate the expression of corresponding autoantigens. Methods Radical prostatectomy specimens of prostate cancer patients (N = 70) were classified into high and low inflammation groups according to the amount of tissue infiltrating lymphocytes. The corresponding pre-surgery blood serum samples were scrutinized for autoantibodies using a low-density protein array. Selected autoantigens were identified in prostate tissue and their expression pattern analyzed by immunohistochemistry and qPCR. The identified autoantibody profile was cross-checked in an independent sample set (N = 63) using the Luminex-bead protein array technology. Results Protein array screening identified 165 autoantibodies differentially abundant in the serum of high compared to low inflammation patients. The expression pattern of three corresponding antigens were established in benign and cancer tissue by immunohistochemistry and qPCR: SPAST (Spastin), STX18 (Syntaxin 18) and SPOP (speckle-type POZ protein). Of these, SPAST was significantly increased in prostate tissue with high inflammation. All three autoantigens were differentially expressed in primary and/or castration resistant prostate tumors when analyzed in an inflammation-independent tissue microarray. Cross-validation of the inflammation autoantibody profile on an independent sample set using a Luminex-bead protein array, retrieved 51 of the significantly discriminating autoantibodies. Three autoantibodies were significantly upregulated in both screens, MUT, RAB11B and CSRP2 (p>0.05), two, SPOP and ZNF671, close to statistical significance (p = 0.051 and 0.076). Conclusions We provide evidence of an inflammation-specific autoantibody profile and confirm the expression of corresponding autoantigens in prostate tissue. This supports evaluation of autoantibodies as non-invasive markers for prostate inflammation. PMID:26863016

  18. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    PubMed Central

    Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L

    2007-01-01

    Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958

  19. Seroprevalence of HDV infection in HBsAg positive population in Ismailia, Egypt.

    PubMed

    Gomaa, Nahed I M; Metwally, Lobna A; Nemr, Nader; Younis, Soha

    2013-01-01

    Hepatitis D virus (HDV) is a defective RNA virus that needs hepatitis B surface antigen (HBsAg) from HBV for transmission. HDV can lead to fulminant hepatitis and the progression of chronic liver damage in patients with chronic hepatitis B. The aim of this study was to determine the seroprevalence of HDV among HBsAg positive individuals in Ismailia, Egypt. Serum samples were collected from 170 HBsAg positive healthy individuals from Suez Canal University blood bank over a one year period. All of them were seeking blood donation and found to be HBsAg positive during viral hepatitis screening workups which is routinely done prior to donation. Serum samples were screened for IgG antibodies to hepatitis delta virus (HDV) using enzyme-linked immunosorbent assay (ELISA) method. Anti-HDV antibodies were detected in 8 (4.7%) individuals aged from 29-43 years. Liver function tests showed that serum ALT and AST levels were elevated in the HBsAglanti-HDV positive cases. It is concluded that the rate of HDV infection in Ismailia is high and further investigation is needed to validate the findings and raise awareness about the risk of dual HBV and HDV infection.

  20. Suspect screening of maternal serum to identify new environmental chemical biomonitoring targets using liquid chromatography-quadrupole time-of-flight mass spectrometry.

    PubMed

    Gerona, Roy R; Schwartz, Jackie M; Pan, Janet; Friesen, Matthew M; Lin, Thomas; Woodruff, Tracey J

    2018-03-01

    The use and advantages of high-resolution mass spectrometry (MS) as a discovery tool for environmental chemical monitoring has been demonstrated for environmental samples but not for biological samples. We developed a method using liquid chromatography-quadrupole time-of-flight MS (LC-QTOF/MS) for discovery of previously unmeasured environmental chemicals in human serum. Using non-targeted data acquisition (full scan MS analysis) we were able to screen for environmental organic acids (EOAs) in 20 serum samples from second trimester pregnant women. We define EOAs as environmental organic compounds with at least one dissociable proton which are utilized in commerce. EOAs include environmental phenols, phthalate metabolites, perfluorinated compounds, phenolic metabolites of polybrominated diphenyl ethers and polychlorinated biphenyls, and acidic pesticides and/or predicted acidic pesticide metabolites. Our validated method used solid phase extraction, reversed-phase chromatography in a C18 column with gradient elution, electrospray ionization in negative polarity and automated tandem MS (MS/MS) data acquisition to maximize true positive rates. We identified "suspect EOAs" using Agilent MassHunter Qualitative Analysis software, to match chemical formulas generated from each sample run with molecular formulas in our unique database of 693 EOAs assembled from multiple environmental literature sources. We found potential matches for 282 (41%) of the EOAs in our database. Sixty-five of these suspect EOAs were detected in at least 75% of the samples; only 19 of these compounds are currently biomonitored in National Health and Nutrition Examination Survey. We confirmed two of three suspect EOAs by LC-QTOF/MS using a targeted method developed through LC-MS/MS, reporting the first confirmation of benzophenone-1 and bisphenol S in pregnant women's sera. Our suspect screening workflow provides an approach to comprehensively scan environmental chemical exposures in humans. This can provide a better source of exposure information to help improve exposure and risk evaluation of industrial chemicals.

  1. Identification of novel serum peptide biomarkers for high-altitude adaptation: a comparative approach

    NASA Astrophysics Data System (ADS)

    Yang, Juan; Li, Wenhua; Liu, Siyuan; Yuan, Dongya; Guo, Yijiao; Jia, Cheng; Song, Tusheng; Huang, Chen

    2016-05-01

    We aimed to identify serum biomarkers for screening individuals who could adapt to high-altitude hypoxia at sea level. HHA (high-altitude hypoxia acclimated; n = 48) and HHI (high-altitude hypoxia illness; n = 48) groups were distinguished at high altitude, routine blood tests were performed for both groups at high altitude and at sea level. Serum biomarkers were identified by comparing serum peptidome profiling between HHI and HHA groups collected at sea level. Routine blood tests revealed the concentration of hemoglobin and red blood cells were significantly higher in HHI than in HHA at high altitude. Serum peptidome profiling showed that ten significantly differentially expressed peaks between HHA and HHI at sea level. Three potential serum peptide peaks (m/z values: 1061.91, 1088.33, 4057.63) were further sequence identified as regions of the inter-α trypsin inhibitor heavy chain H4 fragment (ITIH4 347-356), regions of the inter-α trypsin inhibitor heavy chain H1 fragment (ITIH1 205-214), and isoform 1 of fibrinogen α chain precursor (FGA 588-624). Expression of their full proteins was also tested by ELISA in HHA and HHI samples collected at sea level. Our study provided a novel approach for identifying potential biomarkers for screening people at sea level who can adapt to high altitudes.

  2. Replacing Alpha-Fetoprotein With Alpha-Fetoprotein-L3 Increases the Sensitivity of Prenatal Screening for Trisomy 21.

    PubMed

    Huai, Lei; Leng, Jianhang; Ma, Shenglin; Huang, Fang; Shen, Junya; Ding, Yu

    This study aimed to investigate the serum concentration of alpha-fetoprotein (AFP)-L3 in midterm pregnancies and its potential application in prenatal trisomy screening. The serum samples from 27 women with trisomy 21 fetuses and 800 women with normal fetuses were examined to measure the concentrations of AFP, AFP-L3, human chorionic gonadotropin (hCG), unconjugated estriol (uE3), and inhibin-A. The screening results of various tests consisting of these markers were analyzed. In normal pregnancies within 15-20 weeks of gestation, the medians of serum AFP-L3 were 4.63, 5.70, 5.78, 6.58, 7.03, and 7.25 pg/mL. The median of AFP-L3 MoM in the trisomy 21 group was 0.46, which was significantly lower than the value of 1 in the normal group (P < 0.05). When using a cutoff value of 1/270, the sensitivity of the triple marker test (AFP, hCG, uE3) was improved from 74% to 81% by replacing AFP with AFP-L3, with the false-positive rate slightly increased from 5.4% to 6.8%. Similarly, the sensitivity of the quad marker test (AFP, hCG, uE3, inhibin-A) was improved from 81% to 89% by replacing AFP with AFP-L3, with the false-positive rate slightly increased from 4.6% to 5.6%. Serum AFP-L3 concentration increases along with more weeks of gestation in the midterm pregnancies. Trisomy 21 screening tests with AFP replaced by AFP-L3 have higher sensitivities at the expense of slightly increased false-positive rates. This improvement in screening may help to better prepare the parents and caregivers for the special needs of newborns with trisomy 21.

  3. Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off.

    PubMed

    Schütz, Harald; Auch, Jürgen; Erdmann, Freidoon; Weiler, Günter; Verhoff, Marcel A

    2006-01-01

    Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.

  4. A sensitive time-resolved fluoroimmunoassay for determination of median levels of pregnancy-associated plasma protein a in pregnant women in China.

    PubMed

    Yu, Ting; Gao, Shangxian; Yin, Aihua; Tang, Yongping; Wu, Yingsong; Li, Lili; Li, Ming

    2013-01-01

    Pregnancy-associated plasma protein A (PAPP-A) is an important serum marker for first trimester screening. Its weekly median value varies with ethnicity. A one-step time-resolved fluoroimmunoassay (TRFIA) using two monoclonal antibodies against PAPP-A with Eu(3+) chelates as labels has been developed. Using the assay described here, we evaluated 5,301 normal serum samples from Chinese women at 7-13 weeks of gestation. The detection limit using this assay was 1.2 mIU/L, and the maximum detection range was up to 10,000 mIU/L. The intra-assay and inter-assay coefficients of variation were <3.0% and <5.0%, respectively, and the mean recovery rate was 98.0%. PAPP-A concentrations measured in 516 maternal serum samples correlated well with those obtained by Dissociation-Enhanced Lanthanide Fluorescent Immunoassay (DELFIA) PAPP-A assay (r=0.988, P<0.001). The medians for 7-13 weeks of maternal serum PAPP-A were higher in the women from China compared to reports from other countries. The present assay possesses accuracy and high sensitivity and exhibits great potential for the clinical analysis of PAPP-A. Our investigation on the median concentrations of PAPP-A will help establish reference values that are specific for China and study the importance of ethnic factors in biochemical screening.

  5. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed Central

    Zicker, F.; Smith, P. G.; Luquetti, A. O.; Oliveira, O. S.

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials. PMID:2119903

  6. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed

    Zicker, F; Smith, P G; Luquetti, A O; Oliveira, O S

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials.

  7. Evaluation of Δ(9) -tetrahydrocannabinol detection using DrugWipe5S(®) screening and oral fluid quantification after Quantisal™ collection for roadside drug detection via a controlled study with chronic cannabis users.

    PubMed

    Wille, Sarah M R; Di Fazio, Vincent; Toennes, Stefan W; van Wel, Janelle H P; Ramaekers, Johannes G; Samyn, Nele

    2015-03-01

    Oral fluid (OF) is potentially useful to detect driving under the influence of drugs because of its ease of sampling. While cannabis is the most prevalent drug in Europe, sensitivity issues for Δ(9) -tetrahydrocannabinol (THC) screening and problems during OF collection are observed. The ability of a recently improved OF screening device - the DrugWipe5S(®) , to detect recent THC use in chronic cannabis smokers, was studied. Ten subjects participated in a double-blind placebo-controlled study. The subjects smoked two subsequent doses of THC; 300 µg/kg and 150 µg/kg with a pause of 75 min using a Volcano vapourizer. DrugWipe5S(®) screening and OF collection using the Quantisal™ device were performed at baseline, 5 min after each administration and 80 min after the last inhalation. Blood samples were drawn simultaneously. The screening devices (n = 80) were evaluated visually after 8 min, while the corresponding OF and serum samples were analyzed respectively with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) or gas chromatography-mass spectrometry (GC-MS). Neat OF THC concentrations ranged from 12 361 ng/g 5 min after smoking down to 34 ng/g 80 min later. Under placebo conditions, a median THC concentration of 8 ng/g OF (0-746 ng/g) and < 1 ng/ mL serum (0-7.8 ng/mL) was observed. The DrugWipe5S(®) was positive just after smoking (90%); however, sensitivity rapidly decreased within 1.5 h (50%). Sensitivity of DrugWipe5S(®) should be improved. As chronic cannabis users have high residual THC concentrations in their serum and OF, confirmation cut-offs should be set according to the aim of detecting recent drug use or establishing zero tolerance. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Development of a voltammetric assay, using screen-printed electrodes, for clonazepam and its application to beverage and serum samples.

    PubMed

    Honeychurch, Kevin C; Brooks, Joshua; Hart, John P

    2016-01-15

    This paper describes the development of an electrochemical assay based on screen-printed carbon sensors for the determination of clonazepam in serum and in wine. The cyclic voltammetric behaviour of the drug was investigated and the effects of pH and scan rate on the peak current and peak potential determined. Two reduction peaks were recorded on the initial negative going scan, which were considered to result from the 2e(-), 2 H(+) reduction of the 4,5-azomethine and from the 4e(-), 4 H(+) reduction of the 7-NO2 to a hydroxylamine. On the return positive going scan an oxidation peak was seen, which was considered to result from the 2e(-), 2 H(+) oxidation (O1) of the hydroxylamine to the corresponding nitroso species. At pH 11 the solution of clonazepam was found to turn from clear to yellow in colour and the voltammetric signal of the O1 oxidation process was found to be adsorptive in nature, this was exploited in the development of an adsorptive stripping voltammetric assay. Experimental conditions were then optimised for the differential pulse adsorptive voltammetric measurement of clonazepam in wine and serum samples. It was shown that these analyses could be performed on only 100µL of sample which was deposited on the sensor surface. Mean recoveries of 79.53% (%CV=9.88%) and 88.22% (%CV=14.1%) were calculated for wine fortified with 3.16µg/mL and serum fortified with 12.6µg/mL. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples

    PubMed Central

    Ali, Tamer Awad; Mohamed, Gehad Genidy; Yahya, Ghada A.

    2017-01-01

    This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of lidocaine hydrochloride using modified screen-printed and carbon paste electrodes as end point indicator sensors. The influences of the paste composition, different conditioning parameters and foreign ions on the electrodes performance were investigated and response times of the electrodes were studied. The electrodes showed Nernstian response of 58.9 and 57.5 mV decade-1 in the concentration range of 1×10-7–1×10-2 and 6.2×10-7–1×10-2 mol L-1 for modified screen-printed and carbon paste electrodes, respectively. The electrodes were found to be usable within the pH range of 2.0–8.0 and 2.0-7.5, exhibited a fast response time (about 6 and 4) low detection limit (1×10-7 and 6.2×10-7 mol L-1), long lifetime (6 and 4 months) and good stability for modified screen-printed (Electrode VII) and carbon paste electrodes (Electrode III), respectively. The electrodes were successfully applied for the determination of lidocaine hydrochloride in pure solutions, pharmaceutical preparation and biological fluids (urine and serum) samples. The results obtained applying these potentiometric electrodes were comparable with British pharmacopeia. The method validation parameters were optimized and the method can be applied for routine analysis of lidocaine hydrochloride drug. PMID:28979305

  10. Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples.

    PubMed

    Ali, Tamer Awad; Mohamed, Gehad Genidy; Yahya, Ghada A

    2017-01-01

    This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of lidocaine hydrochloride using modified screen-printed and carbon paste electrodes as end point indicator sensors. The influences of the paste composition, different conditioning parameters and foreign ions on the electrodes performance were investigated and response times of the electrodes were studied. The electrodes showed Nernstian response of 58.9 and 57.5 mV decade -1 in the concentration range of 1×10 -7 -1×10 -2 and 6.2×10 -7 -1×10 -2 mol L -1 for modified screen-printed and carbon paste electrodes, respectively. The electrodes were found to be usable within the pH range of 2.0-8.0 and 2.0-7.5, exhibited a fast response time (about 6 and 4) low detection limit (1×10 -7 and 6.2×10 -7 mol L -1 ), long lifetime (6 and 4 months) and good stability for modified screen-printed (Electrode VII) and carbon paste electrodes (Electrode III), respectively. The electrodes were successfully applied for the determination of lidocaine hydrochloride in pure solutions, pharmaceutical preparation and biological fluids (urine and serum) samples. The results obtained applying these potentiometric electrodes were comparable with British pharmacopeia. The method validation parameters were optimized and the method can be applied for routine analysis of lidocaine hydrochloride drug.

  11. High-throughput Identification of DNA-Encoded IgG Ligands that Distinguish Active and Latent Mycobacterium Tuberculosis Infections

    PubMed Central

    Ndungu, John Maina; Suponitsky-Kroyter, Irena; Cavett, Valerie J.; McEnaney, Patrick J.; MacConnell, Andrew B.; Doran, Todd. M.; Ronacher, Katharina; Stanley, Kim; Utset, Ofelia; Walzl, Gerhard; Paegel, Brian M.; Kodadek, Thomas

    2017-01-01

    The circulating antibody repertoire encodes a patient's health status and pathogen exposure history, but identifying antibodies with diagnostic potential usually requires knowledge of the antigen(s). We previously circumvented this problem by screening libraries of bead-displayed small molecules against case and control serum samples to discover “epitope surrogates” (ligands of IgGs enriched in the case sample). Here, we describe an improved version of this technology that employs DNA-encoded libraries and high-throughput FACS-based screening to discover epitope surrogates that differentiate noninfectious/latent (LTB) patients from infectious/active TB (ATB) patients, which is imperative for proper treatment selection and antibiotic stewardship. Normal control/LTB (10 patients each, NCL) and ATB (10 patients) serum pools were screened against a library (5 × 106 beads, 448k unique compounds) using fluorescent anti-human IgG to label hit compound beads for FACS. Deep sequencing decoded all hit structures and each hit's occurrence frequencies. ATB hits were pruned of NCL hits and prioritized for resynthesis based on occurrence and homology. Several structurally homologous families were identified and 16/21 resynthesized representative hits validated as selective ligands of ATB serum IgGs (p < 0.005). The native secreted TB protein Ag85B (though not the E. coli recombinant form) competed with one of the validated ligands for binding to antibodies, suggesting that it mimics a native Ag85B epitope. The use of DNA-encoded libraries and FACS-based screening in epitope surrogate discovery reveals thousands of potential hit structures. Distilling this list down to several consensus chemical structures yielded a diagnostic panel for ATB composed of thermally stable and economically produced small molecule ligands in place of protein antigens. PMID:27957856

  12. Ratio between serum IL-8 and pepsinogen A/C: a marker for atrophic body gastritis.

    PubMed

    Sanduleanu, S; Bruïne, A D E; Biemond, I; Stridsberg, M; Jonkers, D; Lundqvist, G; Hameeteman, W; Stockbrügger, R W

    2003-02-01

    Elevated serum gastrin and a low pepsinogen A/C ratio are well-recognized markers for atrophic body gastritis (ABG). We have shown that the presence of body atrophy is also associated with elevated serum pro-inflammatory cytokines. This study tested the hypothesis that serum cytokines provide additional information to gastrin and pepsinogens in screening for ABG. Two hundred and twenty-six consecutive patients were investigated on referral for upper gastrointestinal endoscopy: 150 were patients with gastro-oesophageal reflux disease, receiving acid inhibitory medication either with proton pump inhibitors (n = 113) or with histamine2-receptor antagonists (n = 37), and 76 were nontreated controls, who had normal endoscopic findings. Gastric mucosal biopsies were sampled for histological examination (Sydney classification). Serum samples were analyzed for gastrin, chromogranin A (CgA), and pepsinogens A and C by RIA, and for the interleukins (IL)-1beta, IL-6, and IL-8 by ELISA. Subjects with ABG had significantly higher serum gastrin (P < 0.01) and serum CgA (P < 0.01) levels and significantly lower pepsinogen A/C ratios (P < 0.001) than those without ABG. Additionally, serum IL-1beta, IL-6 and, especially, IL-8 levels were significantly higher in the subjects with than in those without ABG (P < 0.0001, for all cytokines). To optimize the detection of body atrophy we defined the ABG index: the ratio between the simultaneously measured IL-8 and pepsinogen A/C. The area under the ROC curve for the ABG index was significantly greater than that for serum gastrin and for serum pepsinogen A/C alone (0.91 +/- 0.029 vs. 0.72 +/- 0.042, and vs. 0.83 +/- 0.031, P = 0.018 and P = 0.049). Using the ABG index at a cut-off value of 1.8 pg mL-1, 91% of the cases were classified correctly. The ratio between serum IL-8 and pepsinogen A/C accurately predicts the presence of ABG. We therefore propose the ABG index as a noninvasive screening test for ABG in population-based studies.

  13. Performance of prenatal screening using maternal serum and ultrasound markers for Down syndrome in Chinese women: a systematic review and meta-analysis.

    PubMed

    Tu, S; Rosenthal, M; Wang, D; Huang, J; Chen, Y

    2016-09-01

    Controversies about the performance of conventional prenatal screening using maternal serum and ultrasound markers (PSMSUM) in detecting Down syndrome (DS) have been raised as a result of a recently available noninvasive prenatal test based on cell-free fetal DNA sequencing. To evaluate the screening performance of PSMSUM in detecting DS in Chinese women. An exhaustive literature search of MEDLINE, Embase, the Cochrane Library, ISI Web of Science and China BioMedical Disc. Primary studies, published from January 2004 to November 2014, which examined the screening accuracy of PSMSUM in pregnant Chinese women, compared with a reference standard, either chromosomal verification or inspection of the newborn. Data were extracted as screening positive/negative results for Down and non-Down syndrome pregnancies, allowing estimation of sensitivities and specificities. Risks of bias within and across studies were assessed. Screening accuracy measures were pooled using a bivariate random effects regression model. Seventy-eight studies, involving six categories of PSMSUM, were included. Second-trimester double serum [pooled sensitivity (SEN) = 0.80, pooled specificity (SPE) = 0.95] and triple-serum (pooled SEN = 0.79, pooled SPE = 0.96) screening were the predominant PSMSUM methods. The screening performances of these methods achieved the national standard but varied enormously across studies. First-trimester combined screening (pooled SEN = 0.92, pooled SPE = 0.93) and second-trimester quadruple serum screening (median SEN = 0.86, median SPE = 0.96) performed better, but were rarely used. Second-trimester maternal serum screening has the potential to achieve satisfactory screening performance in middle- and low-income countries. The reported enormous range in screening performance of second-trimester PSMSUM calls for urgent implementation of methods for performance optimization. Meta-analysis results show good accuracy of maternal serum and ultrasound screening for trisomy 21 in Chinese women. © 2016 Royal College of Obstetricians and Gynaecologists.

  14. Multiplex Immunoassay Profiling of Serum in Psychiatric Disorders.

    PubMed

    Stephen, Laurie; Schwarz, Emanuel; Guest, Paul C

    2017-01-01

    Multiplex immunoassays allow for the rapid profiling of biomarker proteins in biological fluids, using less sample and labour than in single immunoassays. This chapter details the methods to develop and manufacture a 5-plex immunoassay for the Luminex® platform. Although assay development is not included here, the same methods can be used to covalently couple antibodies to the Luminex beads and to label antibodies for the screening of sandwich pairs, if needed. An example will be given for the analysis of five hormones (glucagon-like peptide 1, growth hormone, insulin, leptin and thyroid-stimulating hormone) in serum samples from schizophrenia patients and controls.

  15. Intrathecal oligoclonal IgG bands are infrequently found in neuro-Behçet's disease.

    PubMed

    Saruhan-Direskeneli, Guher; Yentür, S P; Mutlu, Melike; Shugaiv, E; Yesilot, Nilufer; Kürtüncü, M; Akman-Demir, Gulsen

    2013-01-01

    Oligoclonal bands (OCB) of immunoglobulins (IgG) in the cerebrospinal fluid (CSF) provides an evidence for the humoral response and have been screened in the CSF and serum of patients revealing 5 different patterns. In this study, patients with Behçet's disease (BD) are screened in a larger sample to potentially provide information about the possible role of CSF oligoclonal immunoglobulins in the diagnosis of this disease. Paired CSF and serum samples from 121 consecutive BD patients with neurological complaints (43 women and 78 men) were included in this study. Parenchymal NBD was diagnosed in 74 patients, and 22 patients had cerebral venous sinus thrombosis (CVST); of the remaining patients, 18 had primary headache disorders not directly associated with BD, and 7 had a cerebrovascular event. OCB of IgG were detected by isoelectric focusing on agarose and immunoblotting of matched serum and CSF sample pairs. Intrathecal production of IgG only is considered positive (Pattern 2 or 3). In the whole group, only 8 patients had OCB in the CSF showing pattern 2. All these positive cases had parenchymal neuro-BD (10.8% positive and 78.4% negative in parenchymal neuro-BD group). All other groups were negative. The rare presence of oligoclonal IgG bands in CSF can be utilized as another laboratory finding in the diagnosis of NBD.

  16. Performance Characteristics of the Reverse Syphilis Screening Algorithm in a Population With a Moderately High Prevalence of Syphilis.

    PubMed

    Rourk, Angela R; Nolte, Frederick S; Litwin, Christine M

    2016-11-01

    With the recent introduction of automated treponemal tests, a new reverse syphilis algorithm has been proposed and now used by many clinical laboratories. We analyzed the impact of instituting the reverse screening syphilis algorithm in a laboratory that serves a geographic area with a moderately high prevalence of syphilis infection. Serum samples sent for syphilis testing were tested using a treponemal enzyme immunoassay (EIA) as the screening assay. EIA reactive samples were tested by rapid plasma reagin (RPR) and titered to end point if reactive. RPR nonreactive samples were analyzed by the Treponema pallidum particle agglutination test (TP-PA). Pertinent medical records were reviewed for false-reactive screens and samples with evidence of past syphilis infection. Among 10,060 patients tested, 502 (5%) were reactive on the initial EIA screen. The RPR was reactive in 150 (1.5%). TP-PA testing determined that 103 (1.0%) were falsely reactive on initial EIA screen. The reverse screening algorithm, however, identified 242 (2.4%) with evidence of latent, secondary, or past syphilis, 21 of whom had no or unknown prior treatment with antibiotics. Despite a 1.0% false-reactive rate, the reverse syphilis algorithm detected 21 patients with possible latent syphilis that may have gone undetected by traditional syphilis screening. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. The tradition algorithm approach underestimates the prevalence of serodiagnosis of syphilis in HIV-infected individuals.

    PubMed

    Chen, Bin; Peng, Xiuming; Xie, Tiansheng; Jin, Changzhong; Liu, Fumin; Wu, Nanping

    2017-07-01

    Currently, there are three algorithms for screening of syphilis: traditional algorithm, reverse algorithm and European Centre for Disease Prevention and Control (ECDC) algorithm. To date, there is not a generally recognized diagnostic algorithm. When syphilis meets HIV, the situation is even more complex. To evaluate their screening performance and impact on the seroprevalence of syphilis in HIV-infected individuals, we conducted a cross-sectional study included 865 serum samples from HIV-infected patients in a tertiary hospital. Every sample (one per patient) was tested with toluidine red unheated serum test (TRUST), T. pallidum particle agglutination assay (TPPA), and Treponema pallidum enzyme immunoassay (TP-EIA) according to the manufacturer's instructions. The results of syphilis serological testing were interpreted following different algorithms respectively. We directly compared the traditional syphilis screening algorithm with the reverse syphilis screening algorithm in this unique population. The reverse algorithm achieved remarkable higher seroprevalence of syphilis than the traditional algorithm (24.9% vs. 14.2%, p < 0.0001). Compared to the reverse algorithm, the traditional algorithm also had a missed serodiagnosis rate of 42.8%. The total percentages of agreement and corresponding kappa values of tradition and ECDC algorithm compared with those of reverse algorithm were as follows: 89.4%,0.668; 99.8%, 0.994. There was a very good strength of agreement between the reverse and the ECDC algorithm. Our results supported the reverse (or ECDC) algorithm in screening of syphilis in HIV-infected populations. In addition, our study demonstrated that screening of HIV-populations using different algorithms may result in a statistically different seroprevalence of syphilis.

  18. Alkaline phosphatase as a screening test for osteomalacia.

    PubMed

    Chinoy, Muhammad Amin; Javed, Muhammad Imran; Khan, Alamzeb; Sadruddin, Nooruddin

    2011-01-01

    Vitamin D deficiency remains common in children and adults in Pakistan despite adequate sunlight exposure. Diagnosis in adults is usually delayed and is made following pathological fractures that result in significant morbidity. The objective of this study was to see whether Serum Alkaline Phosphatase levels could be used as a screening test for osteomalacia. The Study was conducted at Fatima Hospital, Baqai Medical University, Gadap, Karachi, between July 2002 and June 2005. Serum calcium levels are commonly used to screen patients suspected of osteomalacia, and raised serum alkaline phosphatase (SALP) is considered a diagnostic finding. We used SALP to screen patients who presented with back or non-specific aches and pain of more than six months duration. Three hundred thirty-four (334) patients were screened of which 116 (35%) had raised SALP. Osteomalacia was diagnosed in 92 (79.3%) of these 116 either by plain radiographs, bone biopsy or isotope bone scan. Fifty-four (53.4%) of the 101 cases had a normal level of serum calcium. Osteomalacia is likely to be missed if only serum calcium is used to screen patients. Serum Alkaline Phosphate should be used as the preferred method for screening these patients.

  19. Minimally invasive screening for colitis using attenuated total internal reflectance Fourier transform infrared spectroscopy

    PubMed Central

    Titus, Jitto; Viennois, Emilie; Merlin, Didier; Perera, A. G. Unil

    2016-01-01

    This article describes a rapid, simple and cost-effective technique that could lead to a screening method for colitis without the need for biopsies or in vivo measurements. This screening technique includes the testing of serum using Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) spectroscopy for the colitis-induced increased presence of mannose. Chronic (Interleukin 10 knockout) and acute (Dextran Sodium Sulphate-induced) models for colitis are tested using the ATR-FTIR technique. Arthritis (Collagen Antibody Induced Arthritis) and metabolic syndrome (Toll like receptor 5 knockout) models are also tested as controls. The marker identified as mannose uniquely screens and distinguishes the colitic from the non-colitic samples and the controls. The reference or the baseline spectrum could be the pooled and averaged spectra of non-colitic samples or the subject's previous sample spectrum. This shows the potential of having individualized route maps of disease status, leading to personalized diagnosis and drug management. PMID:27094092

  20. Newborn Screening Guidelines for Congenital Hypothyroidism in India: Recommendations of the Indian Society for Pediatric and Adolescent Endocrinology (ISPAE) - Part I: Screening and Confirmation of Diagnosis.

    PubMed

    Desai, M P; Sharma, R; Riaz, I; Sudhanshu, S; Parikh, R; Bhatia, V

    2018-06-01

    The Indian Society for Pediatric and Adolescent Endocrinology has formulated locally relevant Clinical Practice Guidelines for newborn screening, diagnosis and management of primary congenital hypothyroidism (CH). Screening should be done for every newborn using cord blood, or postnatal blood, ideally at 48 to 72 h of age. On this screen sample, neonates with TSH > 20 mIU/L serum units (or >34 mIU/L for samples taken between 24 to 48 h of age) should be recalled for confirmation. For screen TSH > 40 mIU/L, immediate confirmatory venous T4/FT4 and TSH, and for milder elevation of screen TSH, a second screening TSH at 7 to 10 d of age, should be taken. Preterm and low birth weight infants should undergo screening at 48-72 h postnatal age. Sick babies should be screened at least by 7 d of age. Venous confirmatory TSH >20 mIU/L before age 2 wk and >10 mIU/L after age 2 wk, with low T4 (<10 μg/dL) or FT4 (<1.17 ng/dL) indicate primary CH and treatment initiation. Imaging is recommended by radionuclide scintigraphy and ultrasonography after CH is biochemically confirmed but treatment should not be delayed till scans are performed. Levothyroxine is commenced at 10 to 15 μg/kg in the neonatal period. Serum T4/FT4 is measured at 2 wk and TSH and T4/FT4 at 1 mo, then 2 monthly till 6 mo, 3 monthly from 6 mo-3 y and every 3-6 mo thereafter. Babies with the possibility of transient congenital hypothyroidism should be re-evaluated at age 3 y, to assess the need for lifelong therapy.

  1. Case report: lymphogranuloma venereum proctitis-from rapid screening to molecular confirmation of a masked sexually transmitted disease.

    PubMed

    Markowicz, Mateusz; Grilnberger, Evelyn; Huber, Florian; Leibl, Gabriele; Abrahamian, Heidemarie; Gartner, Manfred; Huber, Monika; Chott, Andreas; Reiter, Michael; Stanek, Gerold

    2013-08-01

    Proctitis caused by Chlamydia trachomatis L2b can manifest with very mild, nonspecific symptoms, and appropriate diagnostic evaluation is crucial. The case report demonstrates that rapid screening test, detection of specific antibodies in serum, and direct pathogen identification by PCR performed on tissue sample or rectal swab allow successful diagnosis of the still emerging sexually transmitted disease among homosexual patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Design of Indigenous ELISA Using Tachyzoites from the RH Strain of Toxoplasma gondii and Comparison with Commercial Kits in Ahvaz, Southwest of Iran, 2015.

    PubMed

    Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman

    2016-10-01

    Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.

  3. Identification of novel serum peptide biomarkers for high-altitude adaptation: a comparative approach

    PubMed Central

    Yang, Juan; Li, Wenhua; Liu, Siyuan; Yuan, Dongya; Guo, Yijiao; Jia, Cheng; Song, Tusheng; Huang, Chen

    2016-01-01

    We aimed to identify serum biomarkers for screening individuals who could adapt to high-altitude hypoxia at sea level. HHA (high-altitude hypoxia acclimated; n = 48) and HHI (high-altitude hypoxia illness; n = 48) groups were distinguished at high altitude, routine blood tests were performed for both groups at high altitude and at sea level. Serum biomarkers were identified by comparing serum peptidome profiling between HHI and HHA groups collected at sea level. Routine blood tests revealed the concentration of hemoglobin and red blood cells were significantly higher in HHI than in HHA at high altitude. Serum peptidome profiling showed that ten significantly differentially expressed peaks between HHA and HHI at sea level. Three potential serum peptide peaks (m/z values: 1061.91, 1088.33, 4057.63) were further sequence identified as regions of the inter-α trypsin inhibitor heavy chain H4 fragment (ITIH4 347–356), regions of the inter-α trypsin inhibitor heavy chain H1 fragment (ITIH1 205–214), and isoform 1 of fibrinogen α chain precursor (FGA 588–624). Expression of their full proteins was also tested by ELISA in HHA and HHI samples collected at sea level. Our study provided a novel approach for identifying potential biomarkers for screening people at sea level who can adapt to high altitudes. PMID:27150491

  4. Segmentectomy for giant pulmonary sclerosing haemangiomas with high serum KL-6 levels

    PubMed Central

    Kuroda, Hiroaki; Mun, Mingyon; Okumura, Sakae; Nakagawa, Ken

    2012-01-01

    We describe a 61-year old female patient with a giant pulmonary sclerosing haemangioma (PSH) and an extremely high preoperative serum KL-6 level. During an annual health screening, the patient showed a posterior mediastinal mass on chest radiography. Chest computed tomography and magnetic resonance imaging revealed a well-circumscribed 60 mm diameter nodule with a marked contrast enhancement in the left lower lobe. The preoperative serum KL-6 level was elevated to 8204 U/ml. We performed a four-port thoracoscopic basal segmentectomy and lymph node sampling for diagnosis and therapy. The postoperative diagnosis showed PSH. The serum KL-6 level decreased dramatically with tumour resection. To the best of our knowledge, this is the first report of a patient with PSH showing a high serum KL-6 level. PMID:22454483

  5. Dendrimer enriched single-use aptasensor for impedimetric detection of activated protein C.

    PubMed

    Erdem, Arzum; Congur, Gulsah

    2014-05-01

    A novel impedimetric aptasensor for detection of human activated protein C (APC) was introduced for the first time in the present study. An enhanced sensor response was obtained using poly(amidoamine) (PAMAM) dendrimer having 16 succinamic acid surface groups (generation 2, G2-PS), that was modified onto the surface of screen printed graphite electrode (G2-PS/SPE). An amino modified DNA aptamer was then immobilized onto the surface of G2-PS modified SPE. The selective interaction of APT with its cognate protein, APC was investigated using different electrochemical techniques; differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The microscopic characterization was consecutively performed before/after each modification/interaction step using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The selectivity of aptasensor was tested in the presence of numerous proteins; protein C, thrombin, bovine serum albumin, factor Va and chromogenic substrate in different buffer mediums. The APC detection in the artificial serum; fetal bovine serum (FBS) was also performed impedimetrically. This dendrimer modified aptasensor technology brings several advantages: being single-use, fast screening with low-cost per measurement and resulting in sensitive detection of APC with the detection limits of 0.74 μg/mL (0.46 pmol in 35 μL sample) in buffer medium, and 2.03 μg/mL (1.27 pmol in 35 μL sample) in serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Gastric adenocarcinoma screening and prevention in the era of new biomarker and endoscopic technologies: a cost-effectiveness analysis.

    PubMed

    Yeh, Jennifer M; Hur, Chin; Ward, Zachary; Schrag, Deborah; Goldie, Sue J

    2016-04-01

    To estimate the cost-effectiveness of noncardia gastric adenocarcinoma (NCGA) screening strategies based on new biomarker and endoscopic technologies. Using an intestinal-type NCGA microsimulation model, we evaluated the following one-time screening strategies for US men: (1) serum pepsinogen to detect gastric atrophy (with endoscopic follow-up of positive screen results), (2) endoscopic screening to detect dysplasia and asymptomatic cancer (with endoscopic mucosal resection (EMR) treatment for detected lesions) and (3) Helicobacter pylori screening and treatment. Screening performance, treatment effectiveness, cancer and cost data were based on published literature and databases. Subgroups included current, former and never smokers. Outcomes included lifetime cancer risk and incremental cost-effectiveness ratios (ICERs), expressed as cost per quality-adjusted-life-year (QALY) gained. Screening the general population at age 50 years reduced the lifetime intestinal-type NCGA risk (0.24%) by 26.4% with serum pepsinogen screening, 21.2% with endoscopy and EMR and 0.2% with H. pylori screening/treatment. Targeting current smokers reduced the lifetime risk (0.35%) by 30.8%, 25.5%, and 0.1%, respectively. For all subgroups, serum pepsinogen screening was more effective and more cost-effective than all other strategies, although its ICER varied from $76,000/QALY (current smokers) to $105,400/QALY (general population). Results were sensitive to H. pylori prevalence, screen age and serum pepsinogen test sensitivity. Probabilistic sensitivity analysis found that at a $100,000/QALY willingness-to-pay threshold, the probability that serum pepsinogen screening was preferred was 0.97 for current smokers. Although not warranted for the general population, targeting high-risk smokers for serum pepsinogen screening may be a cost-effective strategy to reduce intestinal-type NCGA mortality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Survey of prenatal counselling practices regarding aneuploidy risk modification, invasive diagnostic procedure risks, and procedure eligibility criteria in Canadian centres.

    PubMed

    Hull, Danna; Davies, Gregory; Armour, Christine M

    2012-07-01

    To explore prenatal practices related to aneuploidy screening, risk modification, and invasive diagnostic procedures across Canadian centres. We conducted a survey of members of the Canadian Association of Genetic Counsellors, the Canadian College of Medical Genetics, and the Canadian Society of Maternal Fetal Medicine, who provide direct counselling or management of prenatal patients in Canada. Eighty-two of 157 respondents indicated that their centre's definition of advanced maternal age was ≥ 35 years, with 33/157 respondents reporting an advanced maternal age definition of ≥ 40 years. The majority of respondents reported that prenatal serum screening for aneuploidy is provincially funded in their province or territory (121/147). The majority of respondents who reported that prenatal screening is not provincially funded (17/147) were from Quebec (14/17). Thirty-nine of 123 respondents reported that their centre defines increased nuchal translucency as ≥ 3.0 mm, whereas 49/123 reported a definition of ≥ 3.5 mm. Sixty-four of 150 respondents reported that the aneuploidy risk provided by serum screening is modified by a soft marker likelihood ratio, whereas 46/150 respondents reported that both age-related and serum screening risks are modified. Fifty-nine of 124 respondents reported that their centre will modify aneuploidy risk after a normal ultrasound; the most commonly cited negative likelihood ratio was 0.5. The most commonly reported procedure-related risk for chorionic villus sampling was 1/100 (123/147) and for amniocentesis was 1/200 (73/142). This study demonstrates inconsistencies in prenatal practices and access to screening programs across Canada. The information gained from this study will inform policy advisors developing prenatal practice guidelines at both the provincial and national levels.

  8. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.

    PubMed

    Whitehead, S J; Cornes, M P; Ford, C; Gama, R

    2015-01-01

    Exclusion of macroprolactinaemia, a well-recognised interference, as the cause of hyperprolactinaemia is essential to avoid potential misdiagnosis and mismanagement of patients. We have derived gender-specific serum total and post-polyethylene glycol (PEG) precipitation monomeric reference ranges for the recently re-standardised Abbott Architect prolactin assay. Prolactin was measured in serum samples obtained from males (n=49) and females (n=52) using the current Abbott Architect immunoassay pre- and post-PEG precipitation. Gender-specific reference ranges were derived for total and monomeric (post-PEG) prolactin. Routine patients' samples (n=175) with a serum total prolactin >700 mIU/L were screened for macroprolactinaemia to assess classification compared with our previous post-PEG precipitation percentage recovery-based approach. Reference ranges for serum total prolactin were 58-419 mIU/L (male) and 63-561 mIU/L (female). Male and female monomeric prolactin reference ranges were 32-309 mIU/L and 39-422 mIU/L, respectively. Mean (SD) post-PEG percentage recovery of the IS 84/500 prolactin standard was 80 (2.3)%. Of 175 patients' samples screened for macroprolactinaemia, 149 had monomeric prolactin concentrations (median monomeric prolactin=1035 mIU/L; median recovery=83%) above the gender-specific reference range. Monomeric prolactin concentrations (median monomeric prolactin=162 mIU/L; median recovery=20%) in the remaining 26 were within the reference ranges. One patient classified as macroprolactin positive and another classified as macroprolactin negative would not have been identified as such using the previous recovery-based approach. The use of post-PEG monomeric reference ranges not only identifies hyperprolactinaemia due solely to macroprolactinaemia but has the added advantage of identifying patients who have simultaneous true monomeric hyperprolactinaemia and elevated concentrations of macroprolactin. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Preanalytical stability of maternal serum markers hCGβ and PAPP-A.

    PubMed

    Veyrat, Béatrice; Tosetti, François; Morin, Jean-François; Moineau, Marie-Pierre; Piedimonte, Andrée; Clément, Patrice; Dreux, Sophie; Muller, Françoise

    2017-04-01

    Down syndrome maternal serum marker screening is based on a risk calculation including the free β - human chorionic gonadotropin (hCGβ) and pregnancy-associated placenta protein type A (PAPP-A). The aim of this study was to define the pre-analytical conditions of stability of these markers both in whole blood at 15-25 ̊C and, after centrifugation, in serum at 4-8 ̊C. 158 patients were included in the study. Two automated workstations were used for assays, Cobas 8000e602, Roche Diagnostics (58 patients tested) and DELFIAXpress, PerkinElmer (100 patients tested). The stability of markers was studied in whole blood (15-25 ̊C) 2, 4, 6 and 8 hours after sampling and in serum stored after centrifugation at 4-8 ̊C at 24, 72 and 120 hours. Variations were defined by (C T - C 2 )/C 2 , C 2 being the marker concentration at 2 hours and C T the concentration at time T. In whole blood kept for 8 hours at 15-25 ̊C, hCGβ increased by a mean 2.4%, whereas the mean increase of PAPP-A was < 1%. In the serum kept for 5 days at 4-8̊C, the mean increase of hCGβ was 4.2%, with no change in PAPP-A. The impact of these variations on risk calculation is low. In conclusion, maternal serum can be store 8 hours at 15-25̊C in whole blood and 5 days at 4-8̊C after centrifugation and serum separation for Down syndrome maternal serum screening.

  10. Maternal serum alpha-fetoprotein and human chorionic gonadotropin levels in women with human immunodeficiency virus.

    PubMed

    Gross, Susan; Castillo, Wilfrido; Crane, Marilyn; Espinosa, Bialines; Carter, Suzanne; DeVeaux, Richard; Salafia, Carolyn

    2003-04-01

    The purpose of this study was to establish whether there is a correlation between maternal serum genetic screen analyte results in pregnant women with human immunodeficiency virus and corresponding human immunodeficiency virus index values. Medical records of all pregnant women with human immunodeficiency virus who were delivered at Bronx Lebanon Hospital Center from January 2000 through December 2001 were reviewed for maternal serum screen results, viral load, CD4 counts and percent, antiretroviral therapy, opportunistic infections, substance abuse, and other demographic data. Statistical analysis was accomplished with the chi(2) test, Mann-Whitney U test, and Spearman rank correlation test, with a probability value of <.05 considered significant. Of the 98 women with human immunodeficiency virus who were delivered, 49 women (50%) had a maternal serum genetic screen available. Screened and unscreened women had similar severity of human immunodeficiency virus disease, CD4 count and percentage, and viral loads. Serum screen results showed elevations in maternal serum human chorionic gonadotropin (1.43 +/- 1.04 multiples of the median [MoM]; range, 0.2-5.2 MoM) and maternal serum alpha-fetoprotein (1.29 +/- 0.9 MoM; range, 0.5-3.3 MoM) compared with expected values in the general obstetric population. Maternal serum human chorionic gonadotropin was correlated inversely with CD4 count (P =.002) and CD4 percent (P <.0001). Maternal serum alpha-fetoprotein varied directly with viral load (P <.0001). Increasing maternal serum human chorionic gonadotropin and maternal serum alpha-fetoprotein levels in patients with human immunodeficiency virus are correlated with increasing viral load and decreasing CD4 counts.

  11. Antibody screening & identification in the general patient population at a tertiary care hospital in New Delhi, India.

    PubMed

    Makroo, Raj Nath; Bhatia, Aakanksha; Hegde, Vikas; Chowdhry, Mohit; Thakur, Uday Kumar; Rosamma, N L

    2014-09-01

    The development of alloantibodies can significantly complicate transfusion therapy and results in difficulties in cross-matching of blood. Most literature on alloimmunization is limited to multitransfused individuals, with very few studies on the general hospital patients. This study was aimed at assessing the frequency and type of unexpected red cell antibodies in the general patient population at a multispecialty tertiary care centre in New Delhi, India. The results of 49,077 antibody screening tests carried out on patients, from January 2009 to December 2012 were analyzed. The clinical and transfusion records were reviewed. The data were compiled and statistically analysed. A total of 49,077 (29,917; 60.96% males and 19,160; 39.04% females) patient samples were screened for the presence of unexpected antibodies. Antibody screening was positive in 403 patients (0.82%). In the serum samples of 164 patients only autoantibodies were identified, 27 revealed autoantibodies with one or more underlying alloantibodies, while 212 patients had only alloantibody/ies in their serum. The overall alloimmunization rate was 0.49 per cent. Antibodies against the Rh system were the most frequent (64.1%), the most common alloantibody identified being anti E (37.2%), followed by anti D (19.2%). Since clinically significant antibodies are frequently detected in our patient population, antibody screening and if required, identification is the need of the hour. Since antibodies against the common Rh and Kell blood group antigens are the most frequent, provision of Rh and Kell matched red cells may be of protective value.

  12. Second trimester serum cortisol and preterm birth: an analysis by timing and subtype.

    PubMed

    Bandoli, Gretchen; Jelliffe-Pawlowski, Laura L; Feuer, Sky K; Liang, Liang; Oltman, Scott P; Paynter, Randi; Ross, Kharah M; Schetter, Christine Dunkel; Ryckman, Kelli K; Chambers, Christina D

    2018-05-24

    We hypothesized second trimester serum cortisol would be higher in spontaneous preterm births compared to provider-initiated (previously termed 'medically indicated') preterm births. We used a nested case-control design with a sample of 993 women with live births. Cortisol was measured from serum samples collected as part of routine prenatal screening. We tested whether mean-adjusted cortisol fold-change differed by gestational age at delivery or preterm birth subtype using multivariable linear regression. An inverse association between cortisol and gestational age category (trend p = 0.09) was observed. Among deliveries prior to 37 weeks, the mean-adjusted cortisol fold-change values were highest for preterm premature rupture of the membranes (1.10), followed by premature labor (1.03) and provider-initiated preterm birth (1.01), although they did not differ statistically. Cortisol continues to be of interest as a marker of future preterm birth. Augmentation with additional biomarkers should be explored.

  13. Application of Ultrasound-Assisted Surfactant-Enhanced Emulsification Microextraction Based on Solidification of Floating Organic Droplets and High Performance Liquid Chromatography for Preconcentration and Determination of Alprazolam and Chlordiazepoxide in Human Serum Samples.

    PubMed

    Goudarzi, Nasser; Amirnavaee, Monavar; Arab Chamjangali, Mansour; Farsimadan, Sahar

    2017-07-01

    An improved microextraction method is proposed on the basis of ultrasound-assisted surfactant-enhanced emulsification and solidification of a floating organic droplet procedure combined with high performance liquid chromatography for the preconcentration and quantification of alprazolam (ALP) and chlordiazepoxide (CHL) present in a number of human serum samples. Several parameters affecting the extraction efficiency were investigated by the Plackett -Burman factorial design as the screening design. Then the response surface methodology based on the Box-Behnken design was used to optimize the effective parameters in the proposed procedure. The limits of detection for the proposed method were found to be 3.0 and 3.1 ng mL-1 for CHL and ALP, respectively. The calibration curves obtained for the method were linear in the ranges of 10.0-3,500.0 and 10.0-3,000.0 ng mL-1 for CHL and ALP, respectively, with a good determination coefficient. The recoveries of the drugs in the spiked human serum samples were above 93.0%. The developed method was successfully applied to the analysis of these studied drugs in human serum samples. The pre-treatment of the serum samples was performed using acetonitrile to remove the proteins. The proposed procedure was an accurate and reliable one for the determination and preconcentration of these drugs in blood samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Maternal vitamin D deficiency in early pregnancy is not associated with gestational diabetes mellitus development or pregnancy outcomes in Korean pregnant women in a prospective study.

    PubMed

    Park, Sunmin; Yoon, Hyun-Koo; Ryu, Hyun-Mee; Han, You Jung; Lee, Si Won; Park, Bo Kyung; Park, So-Young; Yim, Chang-Hoon; Kim, Sung-Hoon

    2014-01-01

    The association between vitamin D deficiency in the first trimester and GDM development remains controversial in various ethnicities. We prospectively assessed whether pregnant women with vitamin D deficiency during early pregnancy had an increased likelihood of GDM development or poor fetal growth or pregnancy outcomes compared to those with sufficient vitamin D levels. Serum 25-OH-D measurements and fetal ultrasonograms were carried out at 12-14, 20-22, and 32-34 wk in 523 pregnant women. Each woman was screened for GDM at 24-28 wk. There were no differences in serum 25-OH-D levels at 12-14 wk or 22-24 wk of pregnancy between GDM and non-GDM women after adjusting for maternal age, BMI at prepregnancy, BMI at first visit, BMI at GDM screening, gestational age at sampling, previous history of GDM, vitamin D intake, and seasonal variation in sampling. The risk of GDM, insulin resistance, and impaired β-cell function had no association with serum 25-OH-D levels in crude or adjusted logistic regression analysis. GDM was not associated with maternal serum 25-OH-D deficiency during the first trimester or fetal growth during the first and second trimesters. Pregnancy outcomes such as miscarriage, Apgar 1, Apgar 5 and birth weight were independent of maternal serum 25-OH-D levels during the first, second and third trimester of pregnancy. In conclusion, neither GDM prevalence nor fetal growth during pregnancy is associated with vitamin D deficiency at the first trimester in Korean women. Pregnancy outcomes are also independent of maternal vitamin D status.

  15. A new mutation in the AFP gene responsible for a total absence of alpha feto-protein on second trimester maternal serum screening for Down syndrome

    PubMed Central

    Petit, François M; Hébert, Marylise; Picone, Olivier; Brisset, Sophie; Maurin, Marie-Laure; Parisot, Frédéric; Capel, Liliane; Benattar, Clarisse; Sénat, Marie-Victoire; Tachdjian, Gérard; Labrune, Philippe

    2009-01-01

    Alpha feto-protein (AFP) is a major plasma protein produced by the yolk sac and the liver during the fetal period. During the second trimester of pregnancy, APF and βhCG serum concentrations are commonly used for screening Down syndrome. AFP deficiency is rare (estimated to be 1/105 000 newborns) and only one sequence alteration has previously been reported in the AFP gene. We report a new mutation in exon 5 of the AFP gene, leading to a total absence of AFP on 2nd-trimester maternal serum screening for Down syndrome, confirmed on the amniotic fluid. Despite this, fetal development and birth were normal. After PCR-amplification, the whole AFP gene was sequenced. The new mutation was a guanine to adenine transition in position 543 creating a premature stop codon in position 181. In order to search for eventual modifications of the amniotic fluid profile, proteins were separated by electrophoresis and compared with 10 normal amniotic fluids sampled at the same developmental age (18 weeks). In the amniotic fluid of our patient albumin rate was reduced whereas alpha1 and beta protein fractions were increased, suggesting that AFP deficiency may modify the distribution of protein fractions. This observation emphasizes the complex molecular mechanisms of compensation of serum protein deficiency. Studies on other families with AFP deficiency are necessary to confirm this observation. PMID:18854864

  16. [Down syndrome maternal serum screening: results' comments recommended by accredited biologists].

    PubMed

    Muller, F; Dreux, S; Czerkiewicz, I; Bernard, M; Guibourdenche, J; Lacroix, I; Moineau, M-P; Read, M-H; Sault, C; Thibaud, D; Veyrat, B; Bidat, L

    2014-11-01

    Down syndrome maternal serum screening is largely used in France. The aim of this article is to specify and to explain the different comments applied on the reports in order to optimize the management of the patient. These comments represent the consensus of the study group of the biologist accredited for Down syndrome maternal serum screening. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Down syndrome screening in assisted conception twins: an iatrogenic medical challenge.

    PubMed

    Ben-Ami, Ido; Maymon, Ron; Svirsky, Ran; Cuckle, Howard; Jauniaux, Eric

    2013-11-01

    The objective of this study was to provide a critical analysis of the impact of assisted conception on prenatal screening for Down syndrome (DS) in twin pregnancies and the value of various screening modalities for early detection of anomalies. The literature was searched using PubMed and the Cochrane Library focusing on prenatal screening and antenatal care of assisted-conception twin pregnancies. Serum screening alone is of limited value in detecting aneuploid twins, because the unaffected cotwin can "mask" the abnormal serum results of an affected one. In addition, this test can designate the pregnancy as at high risk but not identify the affected fetus. Nuchal translucency (NT) screening is the best available modality and a highly effective screening method for twin pregnancies. Among twins, NT alone has a 69% DS detection rate, first-trimester combined NT and serum biochemistry has a 72% DS detection rate, and an integrated screen will have an 80% DS detection rate at a 5% FPR. The data in the literature concerning the effect of assisted conception on maternal serum screening markers in twin pregnancies are scarce. Down syndrome screening in assisted-conception twins presents clinical and technical challenges. Therefore, assisted-conception twins need close monitoring from conception to delivery, by a practitioner familiar with the available screening modalities and their relative accuracy.

  18. Detection of classical swine fever virus E2 gene in cattle serum samples from cattle herds of Meghalaya.

    PubMed

    Chakraborty, A K; Karam, A; Mukherjee, P; Barkalita, L; Borah, P; Das, S; Sanjukta, R; Puro, K; Ghatak, S; Shakuntala, I; Sharma, I; Laha, R G; Sen, A

    2018-03-01

    The present study focused on the detection and genetic characterisation of 5' untranslated region (5'UTR) and E2 gene of classical swine fever virus (CSFV, family Flaviviridae , genus Pestivirus ) from bovine population of the northeastern region of India. A total of 134 cattle serum samples were collected from organised cattle farms and were screened for CSFV antigen with a commercial antigen capture enzyme linked immunosorbent assay (Ag-ELISA) and reverse transcription-polymerase chain reaction (RT-PCR). A total of 10 samples were positive for CSFV antigen by ELISA, while all of them were positive in PCR for 5'UTR region. Full length E2 region of CSFV were successfully amplified from two positive samples and used for subsequent phylogenetic analysis and determination of protein 3D structure which showed similarity with reported CSFV isolate from Assam of sub-genogroup 2.1, with minor variations in protein structure.

  19. Cancer-associated autoantibodies to MUC1 and MUC4--a blinded case–control study of colorectal cancer in UK collaborative trial of ovarian cancer screening.

    PubMed

    Pedersen, Johannes W; Gentry-Maharaj, Aleksandra; Nøstdal, Alexander; Fourkala, Evangelia-Ourania; Dawnay, Anne; Burnell, Matthew; Zaikin, Alexey; Burchell, Joy; Papadimitriou, Joyce Taylor; Clausen, Henrik; Jacobs, Ian; Menon, Usha; Wandall, Hans H

    2014-05-01

    Recent reports suggest that autoantibodies directed to aberrantly glycosylated mucins, in particular MUC1 and MUC4, are found in patients with colorectal cancer. There is, however, limited information on the autoantibody levels before clinical diagnosis, and their utility in cancer screening in the general population. In our study, we have generated O-glycosylated synthetic MUC1 and MUC4 peptides in vitro, to mimic cancer-associated glycoforms, and displayed these on microarrays. The assay's performance was tested through an initial screening of serum samples taken from patients at the time of colorectal cancer diagnosis and healthy controls. Subsequently, the selected biomarkers were evaluated in a blinded nested case–control study using stored serum samples from among the 50,640 women randomized to the multimodal arm of the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS), where women gave annual blood samples for several years. Cases were 97 postmenopausal women who developed colorectal cancer after recruitment and were age-matched to 97 women without any history of cancer. MUC1-STn and MUC1-Core3 IgG autoantibodies identified cases with 8.2 and 13.4% sensitivity, respectively, at 95% specificity. IgA to MUC4 glycoforms were unable to discriminate between cases and controls in the UKCTOCS sera. Additional analysis was undertaken by combining the data of MUC1-STn and MUC1-Core3 with previously generated data on autoantibodies to p53 peptides, which increased the sensitivity to 32.0% at 95% specificity. These findings suggest that a combination of antibody signatures may have a role as part of a biomarker panel for the early detection of colorectal cancer.

  20. The sero-prevalence of Toxoplasma gondii in British marine mammals.

    PubMed

    Forman, Dan; West, Nathan; Francis, Janet; Guy, Edward

    2009-03-01

    Serum samples from 101 stranded or bycatch cetaceans from British waters were screened for Toxoplasma gondii-specific antibodies using the Sabin Feldman Dye Test. Relatively high seropositivity was recorded in short-beaked Delphinus delphis and this study presents the first documented case of Toxoplasma in a humpback whale Megaptera novaeangliae.

  1. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    PubMed

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be acknowledged. Proteins with shorter serum availability, like S100B, may be superior to proteins such as NF-L in detection of secondary harmful events when monitoring patients with TBI.

  2. Serum expression levels of microRNA-382-3p, -598-3p, -1246 and -184 in breast cancer patients.

    PubMed

    Fu, Lun; Li, Zhaoyun; Zhu, Jie; Wang, Pan; Fan, Guangmin; Dai, Yuechu; Zheng, Zhibao; Liu, Yang

    2016-07-01

    The purpose of the present study was to investigate the serum levels of microRNA (miRNA/miR)-382-3p, -598-3p, -1246 and -184 in breast cancer patients and to assess their feasibility as biomarkers for breast cancer screening. Serum samples were obtained from 100 breast cancer patients and 40 age-matched healthy control subjects in Taizhou Central Hospital (Taizhou, Zhejiang, China) between January 2013 and September 2014. The serum expression levels of miR-382-3p, -598-3p, -1246 and -184 were determined by stem-loop reverse transcription-quantitative polymerase chain reaction. Receiver operating characteristic curves were drawn to evaluate the sensitivity and specificity of the serum miRNA expression levels for the screening of breast cancer. miR-382-3p and -1246 were significantly upregulated in the serum of the breast cancer patients, while miR-598-3p and -184 were significantly downregulated. The sensitivity and specificity to detect breast cancer were as follows: miR-382-3p, 52.0 and 92.5%; miR-598-3p, 95.0 and 85.0%; miR-1246, 93.0 and 75.0%; and miR-184, 87.5 and 71.0%, respectively. The expression levels of the four serum miRNAs were not correlated with the patients' clinical stage. In summary, miR-382-3p, -598-3p, -1246 and -184 are all involved in the development of breast cancer, and are promising biomarkers for breast cancer detection.

  3. Identification and verification of the anabolic steroid boldenone in equine blood and urine by HPLC/ELISA.

    PubMed

    Hagedorn, H W; Schulz, R; Jaeschke, G

    1994-01-01

    An enzyme linked immunosorbent assay (ELISA) was developed to detect the anabolic steroid boldenone in equine blood and urine. The polyclonal antiserum was raised in rabbits, employing boldenone-17-hemisuccinate-bovine serum albumin as antigen. Boldenone-17-hemisuccinate-horseradish peroxidase served as enzyme conjugate. Sensitivity of the assay was 26.0 +/- 3.0 pg/well. Among the endogenous steroids tested only progesterone and testosterone exhibited moderate cross-reactivities, 3.4 and 2.5%, respectively. These cross-reactivities are of no importance for the boldenone assay. For the reduction of background levels, screening for boldenone of equine serum was performed after extraction. Urine samples were determined directly after dilution, omitting hydrolysis of boldenone conjugates. Positive screening results were confirmed by means of two independent HPLC systems combined with off-line detection, employing the boldenone ELISA. Methandienone served as internal standard to ascertain retention factors. In horses treated with boldenone-17-undecylenate the presence of boldenone in serum was confirmed up to 28 days and in unhydrolyzed urine up to 56 days post applicationem.

  4. Detection of autoantibodies against thyroid peroxidase in serum samples of hypothyroid dogs.

    PubMed

    Skopek, Evelyn; Patzl, Martina; Nachreiner, Raymond F

    2006-05-01

    To establish a sensitive test for the detection of autoantibodies against thyroid peroxidase (TPO) in canine serum samples. 365 serum samples from dogs with hypothyroidism as determined on the basis of serum concentrations of total and free triiodothyronine (T3), total and free thyroxine (T4), and thyroid-stimulating hormone, of which 195 (53%) had positive results for at least 1 of 3 thyroid autoantibodies (against thyroglobulin [Tg], T4, or T3) and serum samples from 28 healthy dogs (control samples). TPO was purified from canine thyroid glands by extraction with detergents, ultracentrifugation, and precipitation with ammonium sulfate. Screening for anti-TPO autoantibodies in canine sera was performed by use of an immunoblot assay. Thyroid extract containing TPO was separated electrophoretically, blotted, and probed with canine sera. Alkaline phosphatase-conjugated rabbit anti-dog IgG was used for detection of bound antibodies. TPO bands were observed at 110, 100, and 40 kd. Anti-TPO autoantibodies against the 40-kd fragment were detected in 33 (17%) sera of dogs with positive results for anti-Tg, anti-T4, or anti-T3 autoantibodies but not in sera of hypothyroid dogs without these autoantibodies or in sera of healthy dogs. The immunoblot assay was a sensitive and specific method for the detection of autoantibodies because it also provided information about the antigen. Anti-TPO autoantibodies were clearly detected in a fraction of hypothyroid dogs. The value of anti-TPO autoantibodies for use in early diagnosis of animals with thyroid gland diseases should be evaluated in additional studies.

  5. Human placental growth hormone is increased in maternal serum at 20 weeks of gestation in pregnancies with large-for-gestational-age babies.

    PubMed

    Liao, Shutan; Vickers, Mark H; Taylor, Rennae S; Jones, Beatrix; Fraser, Mhoyra; McCowan, Lesley M E; Baker, Philip N; Perry, Jo K

    2016-12-01

    To investigate the relationship between maternal serum concentrations of placental growth hormone (GH-V), insulin-like growth factor (IGF)-1 and 2, IGF binding proteins (IGFBP)-1 and 3 and birth weight in appropriate-for-gestational-age (AGA), large-for-gestational-age (LGA) and small-for-gestational-age (SGA) cases in a nested case-control study. Maternal serum samples were selected from the Screening for Pregnancy Endpoints (SCOPE) biobank in Auckland, New Zealand. Serum hormone concentrations were determined by ELISA. We found that maternal serum GH-V concentrations at 20 weeks of gestation in LGA pregnancies were significantly higher than in AGA and SGA pregnancies. Maternal GH-V concentrations were positively correlated to birth weights and customized birth weight centiles, while IGFBP-1 concentrations were inversely related to birth weights and customized birth weight centiles. Our findings suggest that maternal serum GH-V and IGFBP-1 concentrations at 20 weeks' gestation are associated with fetal growth.

  6. [Screening for diabetes in France: data from the 2000-2001 cohort of the national medical insurance system].

    PubMed

    Hirtzlin, I; Fagot-Campagna, A; Girard-Le Gallo, I; Vallier, N; Poutignat, N; Weill, A; Le Laidier, S

    2004-04-01

    Type 2 diabetes mellitus may go undiagnosed for several Years while complications are silently developing. In France, from 2 to 3.7% of adults aged 35-65 are unaware they have diabetes. Nevertheless fasting serum glucose is a simple diagnostic test. We described people who underwent opportunist diabetes screening (serum glucose) within 2 Years (2000-2001). We used the administrative EPAS cohort from the employee National Health Insurance System which covers 70% of the total population in France. The data are based on reimbursements of glucose testing and hospitalization among people who did not received reimbursements of treatment for diabetes but used medical services during the 2 Years. The opportunistic screening rate within 2 Years was 48.6% overall and increased with age. Among those 45 Years old or older, it was 71.2%. The screening rate was higher among women than men. Opportunistic screening for diabetes is commonly practised in France, despite the lack of official guidelines. Several hypotheses may explain the discrepancy between common opportunist screening and high prevalence of undiagnosed diabetes: 1). undiagnosed diabetes is mostly present in people who do not use medical services; 2). opportunistic screening is not performed among the most at-risk population; 3). testing is not performed on fasting samples or results are neglected; 4). results of testing are overlooked by doctors/patients; 5). epidemiological studies based on self-report of diagnosis and only one testing overestimate undiagnosed diabetes.

  7. A new approach to epigenome-wide discovery of non-invasive methylation biomarkers for colorectal cancer screening in circulating cell-free DNA using pooled samples.

    PubMed

    Gallardo-Gómez, María; Moran, Sebastian; Páez de la Cadena, María; Martínez-Zorzano, Vicenta Soledad; Rodríguez-Berrocal, Francisco Javier; Rodríguez-Girondo, Mar; Esteller, Manel; Cubiella, Joaquín; Bujanda, Luis; Castells, Antoni; Balaguer, Francesc; Jover, Rodrigo; De Chiara, Loretta

    2018-01-01

    Colorectal cancer is the fourth cause of cancer-related deaths worldwide, though detection at early stages associates with good prognosis. Thus, there is a clear demand for novel non-invasive tests for the early detection of colorectal cancer and premalignant advanced adenomas, to be used in population-wide screening programs. Aberrant DNA methylation detected in liquid biopsies, such as serum circulating cell-free DNA (cfDNA), is a promising source of non-invasive biomarkers. This study aimed to assess the feasibility of using cfDNA pooled samples to identify potential serum methylation biomarkers for the detection of advanced colorectal neoplasia (colorectal cancer or advanced adenomas) using microarray-based technology. cfDNA was extracted from serum samples from 20 individuals with no colorectal findings, 20 patients with advanced adenomas, and 20 patients with colorectal cancer (stages I and II). Two pooled samples were prepared for each pathological group using equal amounts of cfDNA from 10 individuals, sex-, age-, and recruitment hospital-matched. We measured the methylation levels of 866,836 CpG positions across the genome using the MethylationEPIC array. Pooled serum cfDNA methylation data meets the quality requirements. The proportion of detected CpG in all pools (> 99% with detection p value < 0.01) exceeded Illumina Infinium methylation data quality metrics of the number of sites detected. The differential methylation analysis revealed 1384 CpG sites (5% false discovery rate) with at least 10% difference in the methylation level between no colorectal findings controls and advanced neoplasia, the majority of which were hypomethylated. Unsupervised clustering showed that cfDNA methylation patterns can distinguish advanced neoplasia from healthy controls, as well as separate tumor tissue from healthy mucosa in an independent dataset. We also observed that advanced adenomas and stage I/II colorectal cancer methylation profiles, grouped as advanced neoplasia, are largely homogenous and clustered close together. This preliminary study shows the viability of microarray-based methylation biomarker discovery using pooled serum cfDNA samples as an alternative approach to tissue specimens. Our strategy sets an open door for deciphering new non-invasive biomarkers not only for colorectal cancer detection, but also for other types of cancers.

  8. Associations between serum levels of polybrominated diphenyl ether (PBDE) flame retardants and environmental and behavioral factors in pregnant women.

    PubMed

    Buttke, Danielle E; Wolkin, Amy; Stapleton, Heather M; Miranda, Marie Lynn

    2013-03-01

    Polybrominated diphenyl ethers (PBDE) are flame retardants that were previously used in upholstery, fabrics, and household appliances. PBDEs have been linked to adverse health outcomes, including neurotoxicity, thyroid hormone dysregulation, endocrine disruption, and poor semen quality. Because PBDEs pass into placental circulation, maternal exposures can approximate fetal exposures. Our objectives were to determine whether diet and specific human behaviors were significantly associated with PBDE exposures in a cohort of pregnant women. Women between the 34th and 38th week of pregnancy were given a questionnaire about behavioral, environmental, and dietary factors and asked to provide blood samples. Serum PBDE levels were measured using GS-MS and lipid adjusted. An adjusted ordinary least squares regression model was run to identify potential associations between behaviors and serum PBDE levels. Serum concentrations of BDEs 47, 99, 100, and 153 were found above the limit of detection in at least 50% of study participants and used in our models. Associations with serum PBDEs were observed with self-reported hand-to-mouth behaviors, including biting nails and licking fingers. Serum BDE levels of 47, 99, 153, and total PBDEs were also significantly higher in those individuals owning a large-screen TV compared with those who did not. Serum PBDE levels were comparable to levels reported in the general population. Hand-to-mouth behaviors may influence serum PBDE concentrations in adults. Household electronics such as large-screen TVs appear to serve as a significant source of PBDEs in pregnant women. Together, hand-to-mouth behaviors and TV ownership may serve as a route of exposure to PBDEs in adults.

  9. Associations between serum levels of Polybrominated Diphenyl Ether (PBDE) flame retardants and environmental and behavioral factors in pregnant women

    PubMed Central

    Buttke, Danielle E.; Wolkin, Amy; Stapleton, Heather M.; Miranda, Marie Lynn

    2015-01-01

    Background Polybrominated diphenyl ethers (PBDE) are flame retardants that were previously used in upholstery, fabrics, and household appliances. PBDEs have been linked to adverse health outcomes, including neurotoxicity, thyroid hormone dysregulation, endocrine disruption, and poor semen quality. Because PBDEs pass into placental circulation, maternal exposures can approximate fetal exposures. Objectives Our objectives were to determine if diet and specific human behaviors were significantly associated with PBDE exposures in a cohort of pregnant women. Methods Women between the 34th and 38th week of pregnancy were given a questionnaire about behavioral, environmental, and dietary factors and asked to provide blood samples. Serum PBDE levels were measured using GS-MS and lipid adjusted. An adjusted ordinary least squares regression model was run to identify potential associations between behaviors and serum PBDE levels. Results Serum concentrations of BDEs 47, 99, 100, and 153 were found above the limit of detection in at least 50% of study participants and used in our models. Associations with serum PBDEs were observed with self-reported hand-to-mouth behaviors, including biting nails and licking fingers. Serum BDE levels of 47, 99, 153, and total PBDEs were also significantly higher in those individuals owning a large screen TV compared to those who did not. Serum PBDE levels were comparable to levels reported in the general population. Conclusions Hand-to-mouth behaviors may influence serum PBDE concentrations in adults. Household electronics such as large-screen TV’s appear to serve as a significant source of PBDEs in pregnant women. Together, hand-to-mouth behaviors and TV ownership may serve as a route of exposure to PBDEs in adults. PMID:22760441

  10. Monoclonal antibodies specific to sailfish serum albumin: development of an assay for the identification of fish species in the field.

    PubMed

    Rossi, E A; Shepard, S R; Poyer, J C; Hartmann, J X

    1992-06-01

    Balb/c mice were immunized with albumin purified from sailfish (Istiophorus albicans) serum. Hybridomas were produced and screened by ELISA for reactivity with the purified albumins of sailfish, blue marlin (Makaira nigricans) and white marlin (Tetrapturus albidus). Monoclonal antibodies (MAbs) from 16 different clones exhibited activity against sailfish albumin. Thirteen of the MAbs showed cross-reactivity with the marlin species. Three MAbs exhibited distinct specificity for sailfish albumin. One of these species specific MAbs (M2D1) was conjugated to horseradish peroxidase (HRP) in order to construct an ELISA for identification of sailfish from serum. The ELISA for sailfish correctly identified eight sailfish from 26 billfish serum samples. The MAb-peroxidase conjugate was highly specific toward sailfish in that no reaction against heterologous species was detected.

  11. Prevalence of Serum IgG Antibodies to Cystic Echinococcus Antigen among Patients in an Uzbekistan Emergency Hospital.

    PubMed

    Park, Se Jin; Han, Sung Sik; Anvarov, Khikmat; Khajibaev, Abdukhakim; Choi, Min-Ho; Hong, Sung-Tae

    2015-12-01

    Cystic echinococcosis (CE) is one of the most widespread zoonotic helminthiases, which can last an asymptomatic infection for several years. The purpose of this study was to demonstrate serum antibody prevalence of CE among asymptomatic people in Uzbekistan using ELISA. A total of 2,547 serum samples were collected, 66 from confirmed CE patients and 2,481 of patients with other diseases than CE at a hospital in Tashkent, Uzbekistan. The serum samples were screened for CE specific IgG antibodies by ELISA using cystic fluid antigen obtained from sheep. The serum antibody positive rate was 89.4% (59/66) in CE and 3.6% (89/2,481) in other disease patients. The present ELISA recognized 89.4% sensitivity and 96.4% specificity. The ELISA absorbance of positive samples was distributed 0.271-0.971 for CE and 0.273-0.887 for other disease patients. The other disease patients with high absorbance over 0.3 were 50 (2.0%) who were presumed to be active CE patients. The patients in their 40s showed the highest positive rate of 5.2% (P=0.181), and women were 4.4% while men were 3.1% positive (P=0.136). The data confirmed that there are many asymptomatic patients of CE in Tashkent. It is indicated that CE is an endemic disease of public health importance in Uzbekistan.

  12. A data-independent acquisition workflow for qualitative screening of new psychoactive substances in biological samples.

    PubMed

    Kinyua, Juliet; Negreira, Noelia; Ibáñez, María; Bijlsma, Lubertus; Hernández, Félix; Covaci, Adrian; van Nuijs, Alexander L N

    2015-11-01

    Identification of new psychoactive substances (NPS) is challenging. Developing targeted methods for their analysis can be difficult and costly due to their impermanence on the drug scene. Accurate-mass mass spectrometry (AMMS) using a quadrupole time-of-flight (QTOF) analyzer can be useful for wide-scope screening since it provides sensitive, full-spectrum MS data. Our article presents a qualitative screening workflow based on data-independent acquisition mode (all-ions MS/MS) on liquid chromatography (LC) coupled to QTOFMS for the detection and identification of NPS in biological matrices. The workflow combines and structures fundamentals of target and suspect screening data processing techniques in a structured algorithm. This allows the detection and tentative identification of NPS and their metabolites. We have applied the workflow to two actual case studies involving drug intoxications where we detected and confirmed the parent compounds ketamine, 25B-NBOMe, 25C-NBOMe, and several predicted phase I and II metabolites not previously reported in urine and serum samples. The screening workflow demonstrates the added value for the detection and identification of NPS in biological matrices.

  13. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    PubMed

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  14. A Screening Test for Wilson's Disease and its Application to Psychiatric Patients

    PubMed Central

    Cox, Diane Wilson

    1967-01-01

    Varied modes of onset make the early diagnosis of Wilson's disease difficult. A deficiency of serum ceruloplasmin, usually characteristic of the disease, was used as the basis for a screening test. Simple test materials and provision for handling about 50 plasma samples simultaneously made this test feasible for large-scale screening. The screening test was applied to 336 persons hospitalized for psychiatric disorders, to detect patients with Wilson's disease before the classical symptoms appeared. Two patients with ceruloplasmin levels below the normal limits were detected but did not have Wilson's disease. Further application of the screening test to relatives of patients known to have Wilson's disease and to individuals with any symptoms of the disease (hepatic disease, extrapyramidal dysfunction, psychiatric disorders, behaviour problems in children) would aid in early diagnosis and more effective treatment. ImagesFig. 1 PMID:6017170

  15. Development of a qualitative indirect ELISA for the measurement of rabies virus-specific antibodies from vaccinated dogs and cats.

    PubMed

    Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R

    2004-04-01

    A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.

  16. Feasibility of Using Convalescent Plasma Immunotherapy for MERS-CoV Infection, Saudi Arabia.

    PubMed

    Arabi, Yaseen M; Hajeer, Ali H; Luke, Thomas; Raviprakash, Kanakatte; Balkhy, Hanan; Johani, Sameera; Al-Dawood, Abdulaziz; Al-Qahtani, Saad; Al-Omari, Awad; Al-Hameed, Fahad; Hayden, Frederick G; Fowler, Robert; Bouchama, Abderrezak; Shindo, Nahoko; Al-Khairy, Khalid; Carson, Gail; Taha, Yusri; Sadat, Musharaf; Alahmadi, Mashail

    2016-09-01

    We explored the feasibility of collecting convalescent plasma for passive immunotherapy of Middle East respiratory syndrome coronavirus (MERS-CoV) infection by using ELISA to screen serum samples from 443 potential plasma donors: 196 patients with suspected or laboratory-confirmed MERS-CoV infection, 230 healthcare workers, and 17 household contacts exposed to MERS-CoV. ELISA-reactive samples were further tested by indirect fluorescent antibody and microneutralization assays. Of the 443 tested samples, 12 (2.7%) had a reactive ELISA result, and 9 of the 12 had reactive indirect fluorescent antibody and microneutralization assay titers. Undertaking clinical trials of convalescent plasma for passive immunotherapy of MERS-CoV infection may be feasible, but such trials would be challenging because of the small pool of potential donors with sufficiently high antibody titers. Alternative strategies to identify convalescent plasma donors with adequate antibody titers should be explored, including the sampling of serum from patients with more severe disease and sampling at earlier points during illness.

  17. Serum markers for type II diabetes mellitus

    DOEpatents

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D

    2014-03-18

    A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.

  18. Determination of penicillin-G procaine in kidney, muscle, serum, and urine of heavy sows after intramuscular administration

    USDA-ARS?s Scientific Manuscript database

    The United States Department of Agriculture Food Safety and Inspection Service (FSIS) recently adapted the use of the Charm Kidney Inhibition Swab (KIS) test for screening antibiotics on-site, along with a LC-MS/MS method for confirmation of KIS-positive samples. A study with 126 heavy sows (227.0 ...

  19. Sequential cloud-point extraction for toxicological screening analysis of medicaments in human plasma by high pressure liquid chromatography with diode array detector.

    PubMed

    Madej, Katarzyna; Persona, Karolina; Wandas, Monika; Gomółka, Ewa

    2013-10-18

    A complex extraction system with the use of cloud-point extraction technique (CPE) was developed for sequential isolation of basic and acidic/neutral medicaments from human plasma/serum, screened by HPLC/DAD method. Eight model drugs (paracetamol, promazine, chlorpromazine, amitriptyline, salicyclic acid, opipramol, alprazolam and carbamazepine) were chosen for the study of optimal CPE conditions. The CPE technique consists in partition of an aqueous sample with addition of a surfactant into two phases: micelle-rich phase with the isolated compounds and water phase containing a surfactant below the critical micellar concentration, mainly under influence of temperature change. The proposed extraction system consists of two chief steps: isolation of basic compounds (from pH 12) and then isolation of acidic/neutral compounds (from pH 6) using surfactant Triton X-114 as the extraction medium. Extraction recovery varied from 25.2 to 107.9% with intra-day and inter-day precision (RSD %) ranged 0.88-1087 and 5.32-17.96, respectively. The limits of detection for the studied medicaments at λ 254nm corresponded to therapeutic or low toxic plasma concentration levels. Usefulness of the proposed CPE-HPLC/DAD method for toxicological drug screening was tested via its application to analysis of two serum samples taken from patients suspected of drug overdosing. Published by Elsevier B.V.

  20. Acceptability of screening for early detection of liver disease in hazardous/harmful drinkers in primary care.

    PubMed

    Eyles, Caroline; Moore, Michael; Sheron, Nicholas; Roderick, Paul; O'Brien, Wendy; Leydon, Geraldine M

    2013-08-01

    It is estimated that one-quarter of adults in the UK drink at harmful/hazardous levels leading to increased mortality and alcohol liver disease (ALD). The Alcohol Liver Disease Detection Study (ALDDeS) aimed to test out in primary care the feasibility of alcohol misuse screening in adults, using the AUDIT questionnaire, and to assess screening harmful/hazardous alcohol users for ALD using newer non-invasive serum markers of fibrosis. To explore patients' experiences of taking part in ALDDeS and understanding of the delivery and process of screening for ALD using self-report questionnaires and feedback of liver fibrosis risk using levels of non-invasive serum markers. A nested qualitative study based in five primary care practices in the UK. From a sample of patients who were identified as drinking at harmful/hazardous levels, 30 participants were identified by maximum variation sampling for qualitative in-depth interviews. Using the principles of constant comparison the transcribed interviews were thematically analysed. Receiving a postal AUDIT questionnaire was viewed as acceptable by participants. For some completing the AUDIT increased awareness of their hazardous alcohol use and a positive blood test indicating liver fibrosis was a catalyst for behaviour change. For others, a negative blood test result provided a licence to continue drinking at hazardous levels. A limited understanding of safe drinking and of ALD was common. Educational and training needs of primary care professionals must be taken into account, so that patients with marker levels indicating low risk of fibrosis are correctly informed about the likely risks of continuing to drink at the same levels.

  1. Prevalence of Zoonotic and Vector-Borne Infections Among Afghan National Army Recruits in Afghanistan.

    PubMed

    Todd, Catherine S; Mansoor, Ghulam Farooq; Buhler, Cyril; Rahimi, Habiburrahman; Zekria, Rohullah; Fernandez, Stefan; Mikhail, Amy F W; Scott, Paul T; Yingst, Samuel L

    2016-08-01

    To measure prevalence of prior/current Plasmodium vivax and Plasmodium falciparum (PV and PF), Brucella spp. (BR), dengue virus (DENV), Leishmania donovani (visceral leishmaniasis; VL), and Crimean-Congo hemorrhagic fever (CCHF) virus exposure among Afghan National Army (ANA) recruits. Randomly chosen, nationally representative serum samples from consenting men aged 18-40 years and who were screened between February 2010 and January 2011 were tested, with ∼25 samples/province. Samples were screened for PV and PF antigens and VL antibody with rapid diagnostic tests. Reactive malaria screening results were confirmed with polymerase chain reaction assay. Enzyme-linked immunosorbent assays were used to screen for CCHF and DENV antibodies; reactive DENV samples were confirmed with the plaque-reduction neutralization test. BR screening and confirmatory testing was performed with slide and tube agglutination, respectively. Correlates of BR titres >1:80 were analyzed using logistic regression. Of 809 participants contributing specimens, 62% had previously lived outside Afghanistan, predominantly in Pakistan and Iran. CCHF (4.1%, n = 33), DENV (2.1%, n = 17), and VL (1.0%, n = 8) antibody prevalence was low. For PV and PF, only 7 out of 56 reactive samples had detectable nucleic acid. For BR, 8.0% (n = 65) of samples had screening titers >1:40, of which 83.1% had confirmatory titers >1:80. Participants from Kabul and surrounding provinces had lower odds (OR = 0.19, 95% CI: 0.04-1.00) of BR antibody compared with other regions. BR exposure was relatively common with a nearly national distribution, whereas geographic distribution for other pathogens aligned roughly with the expected vector distribution. Public health protection measures should include vector control, food safety, and enhanced diagnostics for acute febrile illness.

  2. Serum expression levels of microRNA-382-3p, −598-3p, −1246 and −184 in breast cancer patients

    PubMed Central

    FU, LUN; LI, ZHAOYUN; ZHU, JIE; WANG, PAN; FAN, GUANGMIN; DAI, YUECHU; ZHENG, ZHIBAO; LIU, YANG

    2016-01-01

    The purpose of the present study was to investigate the serum levels of microRNA (miRNA/miR)-382-3p, −598-3p, −1246 and −184 in breast cancer patients and to assess their feasibility as biomarkers for breast cancer screening. Serum samples were obtained from 100 breast cancer patients and 40 age-matched healthy control subjects in Taizhou Central Hospital (Taizhou, Zhejiang, China) between January 2013 and September 2014. The serum expression levels of miR-382-3p, −598-3p, −1246 and −184 were determined by stem-loop reverse transcription-quantitative polymerase chain reaction. Receiver operating characteristic curves were drawn to evaluate the sensitivity and specificity of the serum miRNA expression levels for the screening of breast cancer. miR-382-3p and −1246 were significantly upregulated in the serum of the breast cancer patients, while miR-598-3p and −184 were significantly downregulated. The sensitivity and specificity to detect breast cancer were as follows: miR-382-3p, 52.0 and 92.5%; miR-598-3p, 95.0 and 85.0%; miR-1246, 93.0 and 75.0%; and miR-184, 87.5 and 71.0%, respectively. The expression levels of the four serum miRNAs were not correlated with the patients' clinical stage. In summary, miR-382-3p, −598-3p, −1246 and −184 are all involved in the development of breast cancer, and are promising biomarkers for breast cancer detection. PMID:27347136

  3. The influence of smoking and parity on serum markers for Down's syndrome screening.

    PubMed

    Tislarić, Dubravka; Brajenović-Milić, Bojana; Ristić, Smiljana; Latin, Visnja; Zuvić-Butorac, Marta; Bacić, Josip; Petek, Marijan; Kapović, Miljenko

    2002-01-01

    To evaluate the impact of smoking and number of previous births on maternal serum levels of alpha-fetoprotein and free beta-subunit of human chorionic gonadotropin (free beta-hCG). The study included 3,252 completed unaffected singleton pregnancies that proceeded beyond 37 weeks' gestation and resulted with a birth of healthy child. Smoking status of mothers and data concerning gravidity and parity were collected at the sampling date. Serum markers were measured between 13 and 22 gestational weeks, corrected for maternal weight, and converted to multiples of median (MoM) for unaffected pregnancy of the corresponding gestational age. Median MoM values for both markers were examined in relation to both: smoking habits and number of previous births. Smokers had significantly decreased free beta-hCG MoM values compared to nonsmokers (p < 0.001). The median levels showed a negative relationship with the number of previous births. The significance of a decreasing trend was proved, both in smokers (p < 0.001) and nonsmokers (p < 0.001). The median maternal serum alpha-fetoprotein MoM values did not show any significant dependence, neither with regard to smoking (p = 0.65) nor with regard to parity (p = 0.07). The recommendable adjustment of serum markers to smoking habits, especially concerning the free beta-hCG levels, would be worthwhile. The evidence of the coexisting influence of parity on serum levels of free beta-hCG, both in smokers and nonsmokers, should perhaps be a stimulus for reconsideration of which corrections the screening performance is dependent on. Copyright 2002 S. Karger AG, Basel

  4. Reproducibility of risk figures in 2nd-trimester maternal serum screening for down syndrome: comparison of 2 laboratories.

    PubMed

    Benn, Peter A; Makowski, Gregory S; Egan, James F X; Wright, Dave

    2006-11-01

    Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.

  5. Autoantibodies to MUC1 glycopeptides cannot be used as a screening assay for early detection of breast, ovarian, lung or pancreatic cancer

    PubMed Central

    Burford, B; Gentry-Maharaj, A; Graham, R; Allen, D; Pedersen, J W; Nudelman, A S; Blixt, O; Fourkala, E O; Bueti, D; Dawnay, A; Ford, J; Desai, R; David, L; Trinder, P; Acres, B; Schwientek, T; Gammerman, A; Reis, C A; Silva, L; Osório, H; Hallett, R; Wandall, H H; Mandel, U; Hollingsworth, M A; Jacobs, I; Fentiman, I; Clausen, H; Taylor-Papadimitriou, J; Menon, U; Burchell, J M

    2013-01-01

    Background: Autoantibodies have been detected in sera before diagnosis of cancer leading to interest in their potential as screening/early detection biomarkers. As we have found autoantibodies to MUC1 glycopeptides to be elevated in early-stage breast cancer patients, in this study we analysed these autoantibodies in large population cohorts of sera taken before cancer diagnosis. Methods: Serum samples from women who subsequently developed breast cancer, and aged-matched controls, were identified from UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS) and Guernsey serum banks to formed discovery and validation sets. These were screened on a microarray platform of 60mer MUC1 glycopeptides and recombinant MUC1 containing 16 tandem repeats. Additional case–control sets comprised of women who subsequently developed ovarian, pancreatic and lung cancer were also screened on the arrays. Results: In the discovery (273 cases, 273 controls) and the two validation sets (UKCTOCS 426 cases, 426 controls; Guernsey 303 cases and 606 controls), no differences were found in autoantibody reactivity to MUC1 tandem repeat peptide or glycoforms between cases and controls. Furthermore, no differences were observed between ovarian, pancreatic and lung cancer cases and controls. Conclusion: This robust, validated study shows autoantibodies to MUC1 peptide or glycopeptides cannot be used for breast, ovarian, lung or pancreatic cancer screening. This has significant implications for research on the use of MUC1 in cancer detection. PMID:23652307

  6. ironPhone: Mobile device-coupled point-of-care diagnostics for assessment of iron status by quantification of serum ferritin.

    PubMed

    Srinivasan, Balaji; O'Dell, Dakota; Finkelstein, Julia L; Lee, Seoho; Erickson, David; Mehta, Saurabh

    2018-01-15

    Iron deficiency (ID) is an urgent public health problem that has devastating effects on maternal and child health. However, due to poor access and affordability, screening and diagnosis for ID is often limited to proxy hemoglobin measurements alone. Here, we report the development and validation of ironPhone, a mobile-device coupled portable diagnostics for quantification of serum ferritin concentrations, an iron status biomarker, within a few minutes, from a drop of fingerprick blood. The ironPhone diagnostic platform comprises of a smartphone accessory, an app, and a disposable lateral flow immunoassay test strip to quantify serum ferritin. For initial validation in the lab, we optimized and evaluated the performance of ironPhone with known ferritin concentrations in spiked buffer and serum samples. Following lab validation, we performed a human validation by collecting fingerprick whole blood samples from 20 participants to assess iron status using ironPhone and compared the results with the laboratory standard IMMULITE 2000 analyzer. Findings from the ironPhone for the buffer and spiked serum samples provided a calibration curve with R 2 values of 0.97 (n=27) and 0.93 (n=12), respectively. On comparison with the laboratory standard IMMULITE analyzer in whole blood samples, a correlation of 0.92 (P<0.0001) was observed with a sensitivity of over 90% for predicting ID (ferritin<15.0µg/L) via the ironPhone, demonstrating its promise for iron status assessment at the point-of-care. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Characterization of immobilization methods of antiviral antibodies in serum for electrochemical biosensors

    NASA Astrophysics Data System (ADS)

    Huy, Tran Quang; Hanh, Nguyen Thi Hong; Van Chung, Pham; Anh, Dang Duc; Nga, Phan Thi; Tuan, Mai Anh

    2011-06-01

    In this paper, we describes different methods to immobilize Japanese encephalitis virus (JEV) antibodies in human serum onto the interdigitated surface of a microelectrode sensor for optimizing electrochemical detection: (1) direct covalent binding to the silanized surface, (2) binding to the silanized surface via a cross-linker of glutaraldehyde (GA), (3) binding to glutaraldehyde/silanized surface via goat anti-human IgG polyclonal antibody and (4) binding to glutaraldehyde/silanized surface via protein A (PrA). Field emission scanning electron microscopy, Fourier transform infrared spectrometry, and fluorescence microscopy are used to verify the characteristics of antibodies on the interdigitated surface after the serum antibodies immobilization. The analyzed results indicate that the use of protein A is an effective choice for immobilization and orientation of antibodies in serum for electrochemical biosensors. This study provides an advantageous immobilization method of serum containing antiviral antibodies to develop electrochemical biosensors for preliminary screening of viruses in clinical samples from outbreaks.

  8. A single, continuous metric to define tiered serum neutralization potency against HIV

    DOE PAGES

    Hraber, Peter Thomas; Korber, Bette Tina Marie; Wagh, Kshitij; ...

    2018-01-19

    HIV-1 Envelope (Env) variants are grouped into tiers by their neutralization-sensitivity phenotype. This helped to recognize that tier 1 neutralization responses can be elicited readily, but do not protect against new infections. Tier 3 viruses are the least sensitive to neutralization. Because most circulating viruses are tier 2, vaccines that elicit neutralization responses against them are needed. While tier classification is widely used for viruses, a way to rate serum or antibody neutralization responses in comparable terms is needed. Logistic regression of neutralization outcomes summarizes serum or antibody potency on a continuous, tier-like scale. It also tests significance of themore » neutralization score, to indicate cases where serum response does not depend on virus tiers. The method can standardize results from different virus panels, and could lead to high-throughput assays, which evaluate a single serum dilution, rather than a dilution series, for more efficient use of limited resources to screen samples from vaccinees.« less

  9. A single, continuous metric to define tiered serum neutralization potency against HIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hraber, Peter Thomas; Korber, Bette Tina Marie; Wagh, Kshitij

    HIV-1 Envelope (Env) variants are grouped into tiers by their neutralization-sensitivity phenotype. This helped to recognize that tier 1 neutralization responses can be elicited readily, but do not protect against new infections. Tier 3 viruses are the least sensitive to neutralization. Because most circulating viruses are tier 2, vaccines that elicit neutralization responses against them are needed. While tier classification is widely used for viruses, a way to rate serum or antibody neutralization responses in comparable terms is needed. Logistic regression of neutralization outcomes summarizes serum or antibody potency on a continuous, tier-like scale. It also tests significance of themore » neutralization score, to indicate cases where serum response does not depend on virus tiers. The method can standardize results from different virus panels, and could lead to high-throughput assays, which evaluate a single serum dilution, rather than a dilution series, for more efficient use of limited resources to screen samples from vaccinees.« less

  10. Indirect electrochemical detection for total bile acids in human serum.

    PubMed

    Zhang, Xiaoqing; Zhu, Mingsong; Xu, Biao; Cui, Yue; Tian, Gang; Shi, Zhenghu; Ding, Min

    2016-11-15

    Bile acids level in serum is a useful index for screening and diagnosis of hepatobiliary diseases. As bile acids concentration is closely related to the degree of hepatobiliary diseases, detecting it is a vital factor to understand the stage of the diseases. The prevalent determination for bile acids is the enzymatic cycling method which has low sensitivity while reagent-consuming. It is desirable to develop a new method with lower cost and higher sensitivity. An indirect electrochemical detection (IED) for bile acids in human serum was established using the screen printed carbon electrode (SPCE). Since bile acids do not show electrochemical signals, they were converted to 3-ketosteroids by 3-α-hydroxysteroid dehydrogenase (3α-HSD) in the presence of nicotinamide adenine dinucleotide (NAD(+)), which was reduced to NADH. NADH could then be oxidized on the surface of SPCE, generating a signal that was used to calculate the total bile acids (TBA) concentration. A good linear calibration for TBA was obtained at the concentration range from 5.00μM to 400μM in human serum. Both the precisions and recoveries were sufficient to be used in a clinical setting. The TBA concentrations in 35 human serum samples by our IED method didn't show significant difference with the result by enzymatic cycling method, using the paired t-test. Moreover, our IED method is reagent-saving, sensitive and cost-effective. Copyright © 2016. Published by Elsevier B.V.

  11. Development and validation of panoptic Meso scale discovery assay to quantify total systemic interleukin-6

    PubMed Central

    Chaturvedi, Shalini; Siegel, Derick; Wagner, Carrie L; Park, Jaehong; van de Velde, Helgi; Vermeulen, Jessica; Fung, Man-Cheong; Reddy, Manjula; Hall, Brett; Sasser, Kate

    2015-01-01

    Aim Interleukin-6 (IL-6), a multifunctional cytokine, exists in several forms ranging from a low molecular weight (MW 20–30 kDa) non-complexed form to high MW (200–450 kDa), complexes. Accurate baseline IL-6 assessment is pivotal to understand clinical responses to IL-6-targeted treatments. Existing assays measure only the low MW, non-complexed IL-6 form. The present work aimed to develop a validated assay to measure accurately total IL-6 (complexed and non-complexed) in serum or plasma as matrix in a high throughput and easily standardized format for clinical testing. Methods Commercial capture and detection antibodies were screened against humanized IL-6 and evaluated in an enzyme-linked immunosorbent assay format. The best antibody combinations were screened to identify an antibody pair that gave minimum background and maximum recovery of IL-6 in the presence of 100% serum matrix. A plate-based total IL-6 assay was developed and transferred to the Meso Scale Discovery (MSD) platform for large scale clinical testing. Results The top-performing antibody pair from 36 capture and four detection candidates was validated on the MSD platform. The lower limit of quantification in human serum samples (n = 6) was 9.77 pg l–1, recovery ranged from 93.13–113.27%, the overall pooled coefficients of variation were 20.12% (inter-assay) and 8.67% (intra-assay). High MW forms of IL-6, in size fractionated serum samples from myelodysplastic syndrome and rheumatoid arthritis patients, were detected by the assay but not by a commercial kit. Conclusion This novel panoptic (sees all forms) IL-6 MSD assay that measures both high and low MW forms may have clinical utility. PMID:25847183

  12. Measurement of yunaconitine and crassicauline A in small-volume blood serum samples by LC-MS/MS: tracing of aconite poisoning in clinical diagnosis.

    PubMed

    Ka-Wing Chung, Karen; Pak-Lam Chen, Sammy; Ng, Sau-Wah; Wing-Lai Mak, Tony; Sze-Yin Leung, Kelvin

    2012-08-15

    Aconite poisoning is one of the most serious types of herb-related medical emergencies. In Hong Kong, many if not most of these poisoning cases are due to confusion in herbal species; that is, the wrong herbs are used in prescriptions. Such human errors, while inevitable perhaps, can be serious, and sometimes fatal. The chemical components responsible for aconite poisoning are yunaconitine and crassicauline A. In the present study, a rapid and sensitive method for the screening and quantification of yunaconitine and crassicauline A in human serum, using LC-MS/MS, was developed and validated. Methyllycaconitine was chosen as the internal standard. The limit of detection (LOD) of yunaconitine and crassicauline A were found to be 0.022 and 0.021 ng/mL, respectively. The limit of quantification (LOQ) was 0.1 ng/mL for both yunaconitine and crassicauline A. The recovery of yunaconitine and crassicauline A ranged from 78.6% to 84.9% and 78.3% to 87.2%, respectively. The matrix effect of yunaconitine and crassicauline A ranged from 110.0% to 130.4% and 121.2 to 130.0%, respectively. Both yunaconitine and crassicauline A were stable in serum for at least 3 months at -20 °C, and the extracts were stable for at least 7 days. For clinical applications, serum samples of two patients confirmed to have had aconite herbs poisoning in 2008 were quantified using the developed method. The result showed that this method can be utilized in clinical routine applications. This screening method expedites the diagnosis in cases of suspected aconite poisoning, thus enabling doctors to treat the condition more quickly and effectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Is maternal serum triple screening a better predictor of Down syndrome in female than in male fetuses?

    PubMed

    Ghidini, A; Spong, C Y; Grier, R E; Walker, C N; Pezzullo, J C

    1998-02-01

    Among euploid gestations, female fetuses have been reported to have significantly lower maternal serum alpha-fetoprotein (MSAFP) and higher human chorionic gonadotropin (hCG) levels than male fetuses. Since in maternal serum triple screening, low MSAFP and high hCG MOM independently confer greater risk of a Down syndrome fetus, we investigated the hypothesis that maternal serum triple screening is more efficacious at detecting female than male Down syndrome fetuses. A database containing all karyotypes from amniocentesis performed between August 1994 and August 1996 was accessed. All trisomy 21 cases were identified. The male-to-female ratio among trisomy 21 fetuses detected at amniocentesis after abnormal maternal serum triple screening was compared with that among trisomy 21 fetuses detected at amniocentesis for advanced maternal age (AMA), which served as the control group. Statistical analysis utilized chi-square, Fisher's exact test, and Student's t-test. A P value of less than 0.05 was considered statistically significant. Forty-nine trisomy 21 fetuses were detected in the women who underwent amniocentesis because of abnormal triple screening and 311 were detected in the control group. The proportion of male fetuses among the triple screening group was not significantly different from that of the AMA group (55 per cent vs. 57 per cent; P=0.9). Our study had a power of 80 per cent to detect a difference of 25 per cent in the male-to-female ratio (alpha=0.05, beta=0.20). The reported differences in MSAFP and hCG levels between male and female euploid fetuses do not appear to affect the sex ratio among Down syndrome fetuses detected because of an abnormal maternal serum triple screening.

  14. Diagnostic potential for gold nanoparticle-based surface-enhanced Raman spectroscopy to provide colorectal cancer screening using blood serum sample

    NASA Astrophysics Data System (ADS)

    Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong

    2011-11-01

    Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.

  15. Diagnostic potential for gold nanoparticle-based surface-enhanced Raman spectroscopy to provide colorectal cancer screening using blood serum sample

    NASA Astrophysics Data System (ADS)

    Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong

    2012-03-01

    Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.

  16. Serum brain-derived neurotrophic factor levels in subjects with major depressive disorder with previous suicide attempt: A population-based study.

    PubMed

    Pedrotti Moreira, Fernanda; Borges, Cristiane Jackson; Wiener, Carolina David; da Silva, Paula Moraes; Portela, Luis Valmor; Lara, Diogo R; da Silva, Ricardo Azevedo; de Mattos Souza, Luciano Dias; Jansen, Karen; Oses, Jean Pierre

    2018-04-01

    Major depressive disorders (MDD) and suicide are significant public health concerns. Recent studies have been demonstrated that alterations in Brain Derived Neurotrophic Factor (BDNF) can be associated with this psychiatric disorders, MDD and suicide. Thus, the aim of this study was to evaluate differences in serum levels in individuals with MDD and with or without suicide attempt (SA), from a population-based sample. This was a paired cross-sectional study nested in a population-based study. The psychopathology screen was performed with the Mini-International Neuropsychiatric Interview (MINI). The total population of the sample consisted of 147 subjects distributed in three groups: 49 healthy controls, 49 subjects with MDD and 49 subjects with MDD and SA (MDD + SA). The BDNF serum levels were significantly reduced in subjects with MDD and MDD + SA compared to the healthy controls. However, there were no significant differences between the MDD and MDD + SA groups with respect to BDNF serum levels. These results suggest that SA did not interfere in the serum levels of BDNF, indicating that this neurotrophin may be related to the diagnosis of MDD and not to suicide attempt. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Micro-RNA Profiling in Human Serum Reveals Compartment-Specific Roles of miR-571 and miR-652 in Liver Cirrhosis

    PubMed Central

    Roderburg, Christoph; Mollnow, Tobias; Bongaerts, Brenda; Elfimova, Natalia; Vargas Cardenas, David; Berger, Katharina; Zimmermann, Henning; Koch, Alexander; Vucur, Mihael; Luedde, Mark; Hellerbrand, Claus; Odenthal, Margarete; Trautwein, Christian; Tacke, Frank; Luedde, Tom

    2012-01-01

    Background and Aims Micro-RNAs (miRNAs) have recently emerged as crucial modulators of molecular processes involved in chronic liver diseases. The few miRNAs with previously proposed roles in liver cirrhosis were identified in screening approaches on liver parenchyma, mostly in rodent models. Therefore, in the present study we performed a systematic screening approach in order to identify miRNAs with altered levels in the serum of patients with chronic liver disease and liver cirrhosis. Methods We performed a systematic, array-based miRNA expression analysis on serum samples from patients with liver cirrhosis. In functional experiments we evaluated the relationship between alterations of miRNA serum levels and their role in distinct cellular compartments involved in hepatic cirrhosis. Results The array analysis and the subsequent confirmation by qPCR in a larger patient cohort identified significant alterations in serum levels of miR-513-3p, miR-571 and miR-652, three previously uncharacterized miRNAs, in patients with alcoholic or hepatitis C induced liver cirrhosis. Of these, miR-571 serum levels closely correlated with disease stages, thus revealing potential as a novel biomarker for hepatic cirrhosis. Further analysis revealed that up-regulation of miR-571 in serum reflected a concordant regulation in cirrhotic liver tissue. In isolated primary human liver cells, miR-571 was up-regulated in human hepatocytes and hepatic stellate cells in response to the pro-fibrogenic cytokine TGF-β. In contrast, alterations in serum levels of miR-652 were stage-independent, reflecting a concordant down-regulation of this miRNA in circulating monocytes of patients with liver cirrhosis, which was inducible by proinflammatory stimuli like bacterial lipopolysaccharide. Conclusion Alterations of miR571 and miR-652 serum levels in patients with chronic liver disease reflect their putative roles in the mediation of fibrogenic and inflammatory processes in distinct cellular compartments involved in the pathogenesis of liver cirrhosis. PMID:22412969

  18. High seroprevalence of antibodies against spotted fever and scrub typhus bacteria in patients with febrile Illness, Kenya.

    PubMed

    Thiga, Jacqueline W; Mutai, Beth K; Eyako, Wurapa K; Ng'ang'a, Zipporah; Jiang, Ju; Richards, Allen L; Waitumbi, John N

    2015-04-01

    Serum samples from patients in Kenya with febrile illnesses were screened for antibodies against bacteria that cause spotted fever, typhus, and scrub typhus. Seroprevalence was 10% for spotted fever group, <1% for typhus group, and 5% for scrub typhus group. Results should help clinicians expand their list of differential diagnoses for undifferentiated fevers.

  19. Determining skeletal maturation using insulin-like growth factor I (IGF-I) test.

    PubMed

    Gupta, Shreya; Jain, Sandhya; Gupta, Puneet; Deoskar, Anuradha

    2012-11-01

    To investigate the validity of Insulin like Growth Factor -1(IGF-1) as a skeletal maturity indicator by comparing serum IGF-1 levels with the stages in cervical vertebral maturation (CVM) and in the middle phalanx of the third finger (MP3). The study population was selected by using simple random sampling technique and consisted of 30 female subjects in the age range of 8-23 years who had blood sample, cephalometric and MP3 radiographs taken on the same day. Serum IGF-I estimation was carried out on the blood samples using chemiluminescence immunoassay (CLIA) method. CVM was evaluated using method by Baccetti et al and MP3 staging was done using Rajagopal & Kansal method. Mean IGF-1 level between the stages was compared by Kruskal-Wallis and Mann Whitney test. Serum IGF-1 levels in females correlate well with skeletal maturity determined by CVM and MP3 stages and increase sharply during early pubertal stages followed by a decrease in late puberty. In addition we hypothesis that serum IGF-1 testing can be undertaken as a preliminary screening test in patients in whom the orthodontist predicts the possibility of using myofunctional appliance but in whom the chronologic age is not suggestive for a growth modification therapy. The finding of the study highlights the fact that the serum IGF-1 estimation can be a valuable tool in assessing skeletal maturation. Copyright © 2012 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

  20. Antineuronal antibodies in idiopathic achalasia and gastro-oesophageal reflux disease

    PubMed Central

    Moses, P L; Ellis, L M; Anees, M R; Ho, W; Rothstein, R I; Meddings, J B; Sharkey, K A; Mawe, G M

    2003-01-01

    Background and aims: The precise aetiology of achalasia is unknown although autoimmunity has been implicated and is supported by several studies. We screened sera from patients with achalasia or gastro-oesophageal reflux disease (GORD) to test for circulating antimyenteric neuronal antibodies. Methods: Serum was obtained from 45 individuals with achalasia, 16 with GORD, and 22 normal controls. Serum was used in immunohistochemistry to label whole mount preparations of ileum and oesophagus of the guinea pig and mouse. Also, sections of superior cervical and dorsal root ganglia, and spinal cord were examined. Results: Positive immunostaining of the myenteric plexus was detected in significantly more achalasia and GORD samples than control samples (achalasia, p<0.001; GORD, p<0.01), and immunoreactivity was significantly more intense with achalasia and GORD serum samples than controls (achalasia, p<0.01; GORD, p<0.05). There was no correlation between intensity of immunoreactivity and duration of achalasia symptoms. In most cases, achalasia and GORD sera stained all ileal submucosal and myenteric neurones, and oesophageal neurones. Immunostaining was not species specific; however, immunostaining was largely specific for enteric neurones. Western blot analysis failed to reveal specific myenteric neuronal proteins that were labelled by antibodies in achalasia or GORD serum. Conclusions: These data suggest that antineuronal antibodies are generated in response to tissue damage or some other secondary phenomenon in achalasia and GORD. We conclude that antineuronal antibodies found in the serum of patients with achalasia represent an epiphenomenon and not a causative factor. PMID:12692044

  1. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  2. A Turkish 3-center study evaluation of serum folic acid and vitamin B12 levels in Alzheimer disease.

    PubMed

    Ulusu, Nuriye Nuray; Yilmaz, Gökhan; Erbayraktar, Zübeyde; Evlice, Ahmet Turan; Aras, Sevgi; Yener, Görsev; Avci, Aslihan

    2015-01-01

    Alzheimer disease, a common proteopathy of advanced age, is characterized by cortical atrophy, neuron degeneration, neuronal loss, and accumulation of extracellular amyloid β plaques. We aimed to investigate serum vitamin B12 and folic acid levels in Alzheimer disease and other dementia patients, as a potential screening test to detect presymptomatic Alzheimer disease in Turkish patients. We evaluated folic acid and vitamin B12 levels in Alzheimer disease patients as well as in other dementia and geriatric patients from Ankara, Dokuz Eylül, and Çukurova university hospitals; 290 female and male geriatric subjects were enrolled. Vitamin B12 and folic acid levels were measured using Roche E170 and Beckman Coulter DXI 800 immunoassays (chemiluminescence) according to the manufacturers' guideline in all centers. We evaluated the results of folic acid and vitamin B12 in Alzheimer disease, other dementias and geriatric patients. No significant difference between the groups regarding the routine control of biochemical parameters was observed. Currently, serum folic and vitamin B12 levels are not diagnostically reliable tests for screening presymptomatic Alzheimer disease. However, the results may statistically be significant if we increase the sample size.

  3. Direct, Label-Free, and Rapid Transistor-Based Immunodetection in Whole Serum.

    PubMed

    Gutiérrez-Sanz, Óscar; Andoy, Nesha M; Filipiak, Marcin S; Haustein, Natalie; Tarasov, Alexey

    2017-09-22

    Transistor-based biosensors fulfill many requirements posed upon transducers for future point-of-care diagnostic devices such as scalable fabrication and label-free and real-time quantification of chemical and biological species with high sensitivity. However, the short Debye screening length in physiological samples (<1 nm) has been a major drawback so far, preventing direct measurements in serum. In this work, we demonstrate how tailoring the sensing surface with short specific biological receptors and a polymer polyethylene glycol (PEG) can strongly enhance the sensor response. In addition, the sensor performance can be dramatically improved if the measurements are performed at elevated temperatures (37 °C instead of 21 °C). With this novel approach, highly sensitive and selective detection of a representative immunosensing parameter-human thyroid-stimulating hormone-is shown over a wide measuring range with subpicomolar detection limits in whole serum. To the best of our knowledge, this is the first demonstration of direct immunodetection in whole serum using transistor-based biosensors, without the need for sample pretreatment, labeling, or washing steps. The presented sensor is low-cost, can be easily integrated into portable diagnostics devices, and offers a competitive performance compared to state-of-the-art central laboratory analyzers.

  4. 3D-Printed Supercapacitor-Powered Electrochemiluminescent Protein Immunoarray

    PubMed Central

    Kadimisetty, Karteek; Mosa, Islam M.; Malla, Spundana; Satterwhite-Warden, Jennifer E.; Kuhns, Tyler; Faria, Ronaldo C.; Lee, Norman H.; Rusling, James F.

    2015-01-01

    Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)32+ (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300–500 fg mL−1 for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training. PMID:26406460

  5. Serum Adenosine Deaminase (ADA) Activity: A Novel Screening Test to Differentiate HIV Monoinfection From HIV-HBV and HIV-HCV Coinfections.

    PubMed

    Abdi, Mohammad; Rahbari, Rizgar; Khatooni, Zahed; Naseri, Nima; Najafi, Adel; Khodadadi, Iraj

    2016-05-01

    CD4(+) cell count, the common HIV infection screening test, is costly and unable to differentiate HIV monoinfection from its concurrent infection with hepatitis B or C virus. We aimed to ascertain diagnostic value of serum adenosine deaminase (ADA) activity as a useful tool to differentiate HIV mono- and co-infection. Blood samples were collected from 30 HIV-HBV and 30 HIV-HCV coinfected patients, 33 HIV positive subjects, and 72 controls. CD4(+) cell count, serum total ADA (tADA), and ADA1, and ADA2 isoenzyme activities were determined and their sensitivity and specificity were computed. tADA and ADA2 activities were significantly higher and CD4(+) counts were markedly lower in all patients compared with controls. Strong inverse agreements between CD4(+) cell counts and both tADA and ADA2 activities were observed. Serum tADA and ADA1 activities showed the highest specificity and the highest sensitivity, respectively, for differentiating HIV monoinfection from HIV-HBV and HIV-HCV coinfections. We showed strong agreement and correlation between CD4(+) cell count and ADA enzyme activity. Based on high ADA sensitivity and specificity, it is concluded that determination of ADA activity might be a novel diagnostic tool to distinguish of HIV monoinfection from its coinfection with HBV or HCV. © 2015 Wiley Periodicals, Inc.

  6. Newborn screening by matrix-assisted laser desorption/ionization mass spectrometry based on parylene-matrix chip.

    PubMed

    Kim, Jo-Il; Noh, Joo-Yoon; Kim, Mira; Park, Jong-Min; Song, Hyun-Woo; Kang, Min-Jung; Pyun, Jae-Chul

    2017-08-01

    Newborn screening for diagnosis of phenylketonuria, homocystinuria, and maple syrup urine disease have been conducted by analyzing the concentration of target amino acids using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) based on parylene-matrix chip. Parylene-matrix chip was applied to MALDI-ToF MS analysis reducing the matrix peaks significantly at low mass-to-charge ratio range (m/z < 500). Reproducibility of inter-spot and intra-spot analyses of amino acids was less than 10%. Methanol extraction was adopted for simple and rapid sample preparation of serum before mass spectrometric analysis showing 13.3 to 45% of extraction efficiency. Calibration curves for diagnosis of neonatal metabolic disorders were obtained by analyzing methanol-extracted serum spiked with target amino acids using MALDI-ToF MS. They showed good linearity (R 2  > 0.98) and the LODs were ranging from 9.0 to 22.9 μg/mL. Effect of proteins in serum was estimated by comparing MALDI-ToF mass spectra of amino acids-spiked serum before and after the methanol extraction. Interference of other amino acids on analysis of target analyte was determined to be insignificant. From these results, MALDI-ToF MS based on parylene-matrix chip could be applicable to medical diagnosis of neonatal metabolic disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    PubMed

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  8. First and second trimester maternal serum inhibin A levels in twins with pre-eclampsia.

    PubMed

    Svirsky, Ran; Maymon, Ron; Melcer, Yaakov; Klog, Esther; Cuckle, Howard

    2016-11-01

    To investigate maternal serum inhibin as a marker of pre-eclampsia (PE) in twins. One hundred forty-three twins and 109 unaffected singleton pregnancies were recruited in the first trimester from the same institution. Blood samples were stored at recruitment and in the second trimester, retrospectively tested for inhibin and values expressed in multiples of the gestation-specific median (MoMs) in singletons, adjusted for maternal weight, as appropriate. The median inhibin level in unaffected twins was 2.04 MoM compared with 1.00 MoM in singletons (P < 0.0001, Wilcoxon Rank Sum Test, one-tailed). Excluding early fetal losses the median in 22 samples from 12 twins with PE was 2.65 MoM compared with 1.99 MoM in 201 samples from 120 unaffected twins (P < 0.02, Wilcoxon Rank Sum Test). This effect was restricted to second trimester samples with medians in cases and controls of 2.86 and 1.91 MoM respectively. Logistic regression of inhibin A together with established PE marker placental growth factor and placental associated plasma protein showed that in the second trimester, it improved screening performance although not reaching statistical significance (P = 0.08). Inhibin A is a potential second trimester marker of PE in twins. It may improve on existing twin screening protocols but more data are required. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.

  9. The hydroxyl-functionalized magnetic particles for purification of glycan-binding proteins.

    PubMed

    Sun, Xiuxuan; Yang, Ganglong; Sun, Shisheng; Quan, Rui; Dai, Weiwei; Li, Bin; Chen, Chao; Li, Zheng

    2009-12-01

    Glycan-protein interactions play important biological roles in biological processes. Although there are some methods such as glycan arrays that may elucidate recognition events between carbohydrates and protein as well as screen the important glycan-binding proteins, there is a lack of simple effectively separate method to purify them from complex samples. In proteomics studies, fractionation of samples can help to reduce their complexity and to enrich specific classes of proteins for subsequent downstream analyses. Herein, a rapid simple method for purification of glycan-binding proteins from proteomic samples was developed using hydroxyl-coated magnetic particles coupled with underivatized carbohydrate. Firstly, the epoxy-coated magnetic particles were further hydroxyl functionalized with 4-hydroxybenzhydrazide, then the carbohydrates were efficiently immobilized on hydroxyl functionalized surface of magnetic particles by formation of glycosidic bond with the hemiacetal group at the reducing end of the suitable carbohydrates via condensation. All conditions of this method were optimized. The magnetic particle-carbohydrate conjugates were used to purify the glycan-binding proteins from human serum. The fractionated glycan-binding protein population was displayed by SDS-PAGE. The result showed that the amount of 1 mg magnetic particles coupled with mannose in acetate buffer (pH 5.4) was 10 micromol. The fractionated glycan-binding protein population in human serum could be eluted from the magnetic particle-mannose conjugates by 0.1% SDS. The methodology could work together with the glycan microarrays for screening and purification of the important GBPs from complex protein samples.

  10. Dried blood spot measurement of pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) from a low-resource setting.

    PubMed

    Browne, J L; Schielen, P C J I; Belmouden, I; Pennings, J L A; Klipstein-Grobusch, K

    2015-06-01

    The objectives of the article is to compare pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) concentrations in dried blood spots (DBSs) with serum of samples obtained from a public hospital in a low-resource setting and to evaluate their stability. Serum and DBS samples were obtained by venipuncture and finger prick from 50 pregnant participants in a cohort study in a public hospital in Accra, Ghana. PAPP-A and β-hCG concentrations from serum and DBS were measured with an AutoDELFIA® (PerkinElmer, PerkinElmer, Turku, Finland) automatic immunoassay. Correlation and Passing-Bablok regression analyses were performed to compare marker levels. High correlation (>0.9) was observed for PAPP-A and β-hCG levels between various sampling techniques. The β-hCG concentration was stable between DBS and serum, PAPP-A concentration consistently lower in DBS. Our findings suggest that β-hCG can be reliably collected from DBS in low-resource tropical settings. The exact conditions of the clinical workflow necessary for reliable PAPP-A measurement in these settings need to be further developed in the future. These findings could have implications for prenatal screening programs feasibility in low-income and middle-income countries, as DBS provides an alternative minimally invasive sampling method, with advantages in sampling technique, stability, logistics, and potential application in low-resource settings. © 2015 John Wiley & Sons, Ltd.

  11. Maternal serum placental growth factor at 12, 22, 32 and 36 weeks' gestation in screening for pre-eclampsia.

    PubMed

    Tsiakkas, A; Cazacu, R; Wright, A; Wright, D; Nicolaides, K H

    2016-04-01

    To examine the distribution of maternal serum placental growth factor (PlGF) at 12, 22, 32 and 36 weeks' gestation in singleton pregnancies which develop pre-eclampsia (PE) and examine the performance of this biomarker in screening for PE. Serum PlGF was measured in 40 212 cases at 11-13 weeks, in 10 282 cases at 19-24 weeks, in 10 400 at 30-34 weeks and 4043 at 35-37 weeks. Bayes' theorem was used to combine the a-priori risk from maternal characteristics and medical history with serum PlGF. The performance of screening for PE requiring delivery < 32, at 32 + 0 to 36 + 6 and ≥ 37 weeks' gestation was estimated. In pregnancies that developed PE, serum PlGF was decreased and the separation in multiples of the median (MoM) values from normal was greater with earlier, compared to later, gestational age at which delivery for PE became necessary. Additionally, the slope of the regression lines of PlGF MoM with gestational age at delivery in pregnancies that developed PE increased with advancing gestational age at screening. The detection rates (DRs), at a false-positive rate (FPR) of 10%, for PE delivering < 32 weeks were 79% and 97% with screening at 12 and 22 weeks, respectively. The DRs for PE delivering at 32 + 0 to 36 + 6 weeks were 57%, 65% and 90% with screening at 12, 22 and 32 weeks. The DRs for PE delivering ≥ 37 weeks were 40%, 37%, 54% and 64% with screening at 12, 22, 32 and 36 weeks, respectively. The performance of combined screening with maternal factors, medical history and PlGF is superior in screening for early, compared to late, PE and improves with advancing gestational age at screening. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  12. Evaluation of the optimal neutrophil gelatinase-associated lipocalin value as a screening biomarker for urinary tract infections in children.

    PubMed

    Kim, Bo Hyun; Yu, Nae; Kim, Hye Ryoun; Yun, Ki Wook; Lim, In Seok; Kim, Tae Hyoung; Lee, Mi-Kyung

    2014-09-01

    Neutrophil gelatinase-associated lipocalin (NGAL) is a promising biomarker in the detection of kidney injury. Early diagnosis of urinary tract infection (UTI), one of the most common infections in children, is important in order to avert long-term consequences. We assessed whether serum NGAL (sNGAL) or urine NGAL (uNGAL) would be reliable markers of UTI and evaluated the appropriate diagnostic cutoff value for the screening of UTI in children. A total of 812 urine specimens and 323 serum samples, collected from pediatric patients, were analyzed. UTI was diagnosed on the basis of culture results and symptoms reported by the patients. NGAL values were measured by using ELISA. NGAL values were more elevated in the UTI cases than in the non-UTI cases, but the difference between the values were not statistically significant (P=0.190 for sNGAL and P=0.064 for uNGAL). The optimal diagnostic cutoff values of sNGAL and uNGAL for UTI screening were 65.25 ng/mL and 5.75 ng/mL, respectively. We suggest that it is not appropriate to use NGAL as a marker for early diagnosis of UTI in children.

  13. Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification.

    PubMed

    Uludag, Yildiz; Tothill, Ibtisam E

    2012-07-17

    Early detection of cancer is vital for the successful treatment of the disease. Hence, a rapid and sensitive diagnosis is essential before the cancer is spread out to the other body organs. Here we describe the development of a point-of-care immunosensor for the detection of the cancer biomarker (total prostate-specific antigen, tPSA) using surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) sensor platforms in human serum samples. K(D) of the antibody used toward PSA was calculated as 9.46 × 10(-10) M, indicating high affinity of the antibody used in developing the assay. By performing a sandwich assay using antibody-modified nanoparticles concentrations of 2.3 ng mL(-1) (Au, 20 nm) and 0.29 ng mL(-1) (8.5 pM) (Au, 40 nm) tPSA in 75% human serum were detected using the developed assay on an SPR sensor chip. The SPR sensor results were found to be comparable to that achieved using a QCM sensor platform, indicating that both systems can be applied for disease biomarkers screening. The clinical applicability of the developed immunoassay can therefore be successfully applied to patient's serum samples. This demonstrates the high potential of the developed sensor devices as platforms for clinical prostate cancer diagnosis and prognosis.

  14. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients.

    PubMed

    Pham, Thuy Anh Vu

    2017-11-01

    The aims of this case control study were to correlate the serum and salivary urea as well as creatinine levels; and to evaluate salivary urea and creatinine as noninvasive alternatives to serum for creatinine estimation in chronic kidney disease (CKD) patients. Blood and saliva samples were collected from 112 CKD patients and 108 subjects without CKD for quantitative analysis of urea and creatinine. Spearman's correlation coefficients between salivary and serum urea as well as creatinine were obtained. Receiver operating characteristic analysis was done to assess the diagnostic tests of salivary urea and creatinine. Cut-off values were determined based on the best trade-off between the sensitivity and specificity for both salivary urea and creatinine. Salivary urea and creatinine concentrations were significantly higher in CKD patients than those in control subjects; and increased by the stages of the severity of the disease. The positive correlation was significantly found between salivary and serum creatinine (r  =  0.90) and between salivary and serum urea (r  =  0.73). Area under the curve for salivary urea was 0.76 and a cut-off value of 14.25 mmol/L gave a sensitivity of 82.9% and specificity of 57.8%. Area under the curve for salivary creatinine was 0.92 and a cut-off value of 0.24 mg/dL gave a sensitivity of 86.5% and specificity of 87.2%. Both salivary urea and creatinine have a high capacity for serum creatinine estimation. Salivary urea and creatinine tests can be used as low-cost, easily accessible and noninvasive tools for screening, diagnosing, monitoring treatment outcomes and ascertaining prognosis of chronic kidney disease.

  15. Webinar Presentation: Suspect Screening of Environmental Organic Acids in Human Serum Using High-resolution Mass Spectrometry (HRMS)

    EPA Pesticide Factsheets

    This presentation, Suspect Screening of Environmental Organic Acids in Human Serum Using High-resolution Mass Spectrometry (HRMS), was given at the NIEHS/EPA Children's Centers 2016 Webinar Series: Exposome held on May 11, 2016.

  16. Identification of patients with nasopharyngeal carcinoma by serum protein profiling using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Zhu, Xiao-Dong; Su, Fang; Liang, Zhong-Guo; Li, Ling; Qu, Song; Liang, Xia; Wang, Qi; Liang, Shi-Xiong; Chen, Long

    2014-08-01

    As diagnosis of nasopharyngeal carcinoma at an early disease stage is important, we attempted to distinguish between patients with nasopharyngeal carcinoma and noncancer controls by using serum protein profiles. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry and CM10 protein chip were used to detect the serum proteomic patterns of 65 patients with nasopharyngeal carcinoma before radiotherapy and 93 noncancer controls. Proteomic spectra of serum samples from 50 nasopharyngeal carcinoma patients and 60 noncancer controls were used as a training set. The validity of the classification tree was then challenged with a blind test set which included another 15 patients with nasopharyngeal carcinoma and 33 noncancer controls. Biomarker Wizard 3.01 and Biomarker Pattern 5.01 were used in combination to analyze the data and to develop diagnostic models. 21 protein peaks were significantly different between nasopharyngeal carcinoma and controls. 4 mass peaks (M4182, M5343, M5913 and M8702 mass/charge ratio) were chosen automatically to construct a classification tree. The classification tree correctly determined 93.8 % (45/48) of the test samples with 93.3 % (14/15) of the nasopharyngeal carcinoma samples and 93.9 % (31/33) of the noncancer samples. Using a combination of serum protein profiles and Epstein-Barr viral capsid antigen immunoglobulin A antibody tests, the diagnostic sensitivity and specificity were increased to 100 and 97 %, respectively. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry could correctly distinguish nasopharyngeal carcinoma from noncancer individuals and showed great potential for the development of a screening test for the detection of nasopharyngeal carcinoma.

  17. Competitive immunoassay for analysis of bisphenol A in children's sera using a specific antibody.

    PubMed

    Yang, Fanfan; Xu, Long; Zhu, Lixin; Zhang, Ying; Meng, Wei; Liu, Renrong

    2016-06-01

    Bisphenol A (BPA) has been reported as a potential estrogenic substance that could affect human health and reproduction. In this study, a monoclonal antibody (Mab) against BPA was produced after the immunization of Balb/c mice with a conjugate of 4,4-bis (4-hydroxyphenyl) valeric acid coupling with keyhole limpet hemocyanin (BVA-KLH). The obtained Mab showed higher affinity against BPA and lower cross-reactivity toward 4,4'-sulfonyldiphenol, diphenolic acid, hydroquinone, salicylic acid, and other common phenolic compounds. Basing on the Mab, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was developed. Under the optimal conditions, the limit of detection (LOD) was found to be 0.1 ng mL(-1) with the linear working range of 0.45-10.56 ng mL(-1). After sample extraction, the fortified serum samples were detected with intra- and inter-assay recovery ranges of 81.2-92.9 and 84.4-94.4 %, respectively. Then, 100 children's sera were screened by ic-ELISA. The result showed that 54 % of the serum samples were BPA-positive. The positive samples were purified by immuno-affinity column (IAC) and further confirmed by high-performance liquid chromatography (HPLC) with fluorescence detector measured at λ ex/λ em 228/310 nm in acetonitrile-water solution (v:v, 40:60). The analysis of the unknown samples showed that ic-ELISA agreed well with the HPLC results. It also revealed that the ELISA developed here could be a useful tool for screening BPA in children's sera before the validation of HPLC.

  18. Clinical Investigation Program Report.

    DTIC Science & Technology

    1981-10-01

    Resident Surgical Instructional Experience. (T) 41 1979 Routine Use of Serum Uric Acid Levels at 36 Weeks Gestation as Screening Test for Preeclampsia as...Title: Routine Use of Serum Uric Acid Levels at 36 Weeks Gestation as Screening Test for Preeclampsia as an Aid to Further Management. Start Date: Jan 80...Knight, MC Key Words: Serum Uric Acid Preeclampsia Ac,-uulative MEDCASE -rEst Accumulative Periodic Jan 81 Cost: OMA Cost: I Revie , Results Continue

  19. Racial and Ethnic Variation in Time to Prostate Biopsy After an Elevated Screening Level of Serum Prostate-specific Antigen.

    PubMed

    Reading, Stephanie R; Porter, Kimberly R; Hsu, Jin-Wen Y; Wallner, Lauren P; Loo, Ronald K; Jacobsen, Steven J

    2016-10-01

    To examine the racial and ethnic variation in time to prostate biopsy after an elevated screening level of serum prostate-specific antigen (PSA). Male members of the Kaiser Permanente of Southern California health plan, 45 years of age or older, with no history of prostate cancer or a prostate biopsy, and at least 1 elevated screening level of serum PSA between January 1, 1998 and December 31, 2007 were retrospectively identified (n = 59,506). All participants were passively followed via electronic health records until their time of prostate biopsy, death, membership disenrollment, or study conclusion (December 31, 2014), whichever was the initial event. Proportional hazard regression analyses were used to estimate the association between time from an elevated screening level of serum PSA to prostate biopsy, adjusting for age, benign prostatic hyperplasia, prostatitis, type 2 diabetes mellitus, hypertension, and Charlson Comorbidity Index score. Median time until biopsy was 0.6 years (214 days), with approximately 41% of participants receiving a prostate biopsy within the study period. Results from the fully adjusted analysis indicated that the non-Hispanic Asian or Pacific Islanders (hazard ratio: 1.10, 95% confidence interval: [1.04, 1.15]) and the non-Hispanic blacks (hazard ratio: 1.04, 95% confidence interval: [1.00, 1.08]) had a slightly shorter time to prostate biopsy after an elevated screening level of serum PSA compared to the non-Hispanic whites. These data suggest that, within an integrated healthcare organization, minimal differences exist between racial and ethnic subgroups in their time to prostate biopsy after an elevated screening level of serum PSA. Copyright © 2016. Published by Elsevier Inc.

  20. Detection of influenza A virus nucleoprotein antibodies in oral fluid specimens from pigs infected under experimental conditions using a blocking ELISA.

    PubMed

    Panyasing, Y; Goodell, C K; Wang, C; Kittawornrat, A; Prickett, J R; Schwartz, K J; Ballagi, A; Lizano, S; Zimmerman, J J

    2014-04-01

    In commercial swine populations, influenza is an important component of the porcine respiratory disease complex (PRDC) and a pathogen with major economic impact. Previously, a commercial blocking ELISA (FlockChek(™) Avian Influenza Virus MultiS-Screen(®) Antibody Test Kit, IDEXX Laboratories, Inc., Westbrook, ME, USA) designed to detect influenza A nucleoprotein (NP) antibodies in avian serum was shown to accurately detect NP antibodies in swine serum. The purpose of this study was to determine whether this assay could detect NP antibodies in swine oral fluid samples. Initially, the procedure for performing the NP-blocking ELISA on oral fluid was modified from the serum testing protocol by changing sample dilution, sample volume, incubation time and incubation temperature. The detection of NP antibody was then evaluated using pen-based oral fluid samples (n = 182) from pigs inoculated with either influenza A virus subtype H1N1 or H3N2 under experimental conditions and followed for 42 days post inoculation (DPI). NP antibodies in oral fluid were detected from DPI 7 to 42 in all inoculated groups, that is, the mean sample-to-negative (S/N) ratio of influenza-inoculated pigs was significantly different (P < 0.0001) from uninoculated controls (unvaccinated or vaccinated-uninoculated groups) through this period. Oral fluid versus serum S/N ratios from the same pen showed a correlation of 0.796 (Pearson's correlation coefficient, P < 0.0001). The results showed that oral fluid samples from influenza virus-infected pigs contained detectable levels of NP antibodies for ≥42 DPI. Future research will be required to determine whether this approach could be used to monitor the circulation of influenza virus in commercial pig populations. © 2012 Blackwell Verlag GmbH.

  1. Thrombospondin Type-1 Domain-Containing 7A in Idiopathic Membranous Nephropathy

    PubMed Central

    Meyer-Schwesinger, Catherine; Seitz-Polski, Barbara; Ma, Hong; Zahner, Gunther; Dolla, Guillaume; Hoxha, Elion; Helmchen, Udo; Dabert-Gay, Anne-Sophie; Debayle, Delphine; Merchant, Michael; Klein, Jon; Salant, David J.; Stahl, Rolf A.K.; Lambeau, Gérard

    2014-01-01

    BACKGROUND Idiopathic membranous nephropathy is an autoimmune disease. In approximately 70% of patients, it is associated with autoantibodies against the phospholipase A2 receptor 1 (PLA2R1). Antigenic targets in the remaining patients are unknown. METHODS Using Western blotting, we screened serum samples from patients with idiopathic membranous nephropathy, patients with other glomerular diseases, and healthy controls for antibodies against human native glomerular proteins. We partially purified a putative new antigen, identified this protein by means of mass spectrometry of digested peptides, and validated the results by analysis of recombinant protein expression, immunoprecipitation, and immunohistochemical analysis. RESULTS Serum samples from 6 of 44 patients in a European cohort and 9 of 110 patients in a Boston cohort with anti-PLA2R1–negative idiopathic membranous nephropathy recognized a glomerular protein that was 250 kD in size. None of the serum samples from the 74 patients with idiopathic membranous nephropathy who were sero-positive for anti-PLA2R1 antibodies, from the 76 patients with other glomerular diseases, and from the 44 healthy controls reacted against this antigen. Although this newly identified antigen is clearly different from PLA2R1, it shares some biochemical features, such as N-glycosylation, membranous location, and reactivity with serum only under nonreducing conditions. Mass spectrometry identified this antigen as thrombospondin type-1 domain-containing 7A (THSD7A). All reactive serum samples recognized recombinant THSD7A and immunoprecipitated THSD7A from glomerular lysates. Moreover, immunohistochemical analyses of biopsy samples from patients revealed localization of THSD7A to podocytes, and IgG eluted from one of these samples was specific for THSD7A. CONCLUSIONS In our cohort, 15 of 154 patients with idiopathic membranous nephropathy had circulating autoantibodies to THSD7A but not to PLA2R1, a finding that suggests a distinct subgroup of patients with this condition. (Funded by the French National Center for Scientific Research and others.) PMID:25394321

  2. HIV‑2 antibody detection after indeterminate or negative HIV‑1 Western blot in Cuba, 2005-2008.

    PubMed

    Díaz, Dervel F; Ortiz, Eva; Martín, Dayamí; Nibot, Carmen; Rizo, Adis; Silva, Eladio

    2012-01-01

    INTRODUCTION Differentiating between HIV-1 and HIV-2 infection is the first step to understanding HIV transmission, epidemiology and pathogenesis in geographical areas where both viruses circulate. In Cuba, positive results in mixed HIV-1/2 screening assays are confirmed by HIV-1 Western blot. Indeterminate results constitute the main limitation of this test and HIV-2 infection is among their possible causes; hence the importance of second-stage screening and confirmatory tests for HIV-2 infection. OBJECTIVE Investigate the contribution of HIV-2 antibodies to negative or indeterminate HIV-1 Western blot results in serum samples from 2005 through 2008 in Cuba. METHODS HIV-2 reactivity was studied using the ELISA DAVIH-VIH-2 diagnostic kit (Cuba) in 1723 serum samples with negative or indeterminate results for HIV-1 Western blot from January 2005 through December 2008. Duplicate sera reactive by ELISA were confirmed by HIV-2 Western blot, results interpreted according to WHO criteria. The epidemiological interview established by Cuba's National Program for Prevention and Control Sexually-Transmitted Diseases and HIV/AIDS was applied to HIV-2 Western blot-positive patients. RESULTS Among all sera studied, HIV-2 ELISA identified 12 reactive serum samples (0.70%) and 1711 non-reactive (99.30%). Western blot analysis of the 12 ELISA-reactive samples confirmed two positive samples (16.67%), 4 negative (33.33%) and 6 indeterminate (50%). Positive samples reacted against the p16, p26, gp36, p53, p56, p68 and gp105 proteins. All 12 ELISA-reactive samples belonged to the HIV-1 Western blot indeterminate group. The two HIV-2-positive samples showed well defined reactivity to gp160, p53, p55 and p34 of HIV-1. HIV-1 seroconversion was observed in all 10 remaining samples during serological followup. CONCLUSIONS Two new HIV-2 seropositive cases were diagnosed using DAVIH-VIH-2 and HIV-2 Western blot in indeterminate HIV-1 Western blot samples. Results support the recommendation that HIV-2 Western blot be included in the diagnostic algorithm for HIV-1/2 to followup negative or indeterminate HIV-1 Western blot results. KEYWORDS Diagnosis, laboratory techniques and procedures, antibodies, HIV-2, Western blot, enzyme-linked immunosorbent assay, algorithm, Cuba.

  3. Ultra-sensitive high performance liquid chromatography-laser-induced fluorescence based proteomics for clinical applications.

    PubMed

    Patil, Ajeetkumar; Bhat, Sujatha; Pai, Keerthilatha M; Rai, Lavanya; Kartha, V B; Chidangil, Santhosh

    2015-09-08

    An ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique has been developed by our group at Manipal, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from volunteers (normal, and different pre-malignant/malignant conditions) were recorded using this set-up. The protein profiles were analyzed using principal component analysis (PCA) to achieve objective detection and classification of malignant, premalignant and healthy conditions with high sensitivity and specificity. The HPLC-LIF protein profiling combined with PCA, as a routine method for screening, diagnosis, and staging of cervical cancer and oral cancer, is discussed in this paper. In recent years, proteomics techniques have advanced tremendously in life sciences and medical sciences for the detection and identification of proteins in body fluids, tissue homogenates and cellular samples to understand biochemical mechanisms leading to different diseases. Some of the methods include techniques like high performance liquid chromatography, 2D-gel electrophoresis, MALDI-TOF-MS, SELDI-TOF-MS, CE-MS and LC-MS techniques. We have developed an ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from healthy and volunteers with different malignant conditions were recorded by using this set-up. The protein profile data were analyzed using principal component analysis (PCA) for objective classification and detection of malignant, premalignant and healthy conditions. The method is extremely sensitive to detect proteins with limit of detection of the order of femto-moles. The HPLC-LIF combined with PCA as a potential proteomic method for the diagnosis of oral cancer and cervical cancer has been discussed in this paper. This article is part of a Special Issue entitled: Proteomics in India. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Investigation of novel biomarkers for predicting the clinical course in patients with ulcerative colitis.

    PubMed

    Hamanaka, Shinsaku; Nakagawa, Tomoo; Hiwasa, Takaki; Ohta, Yuki; Kasamatsu, Shingo; Ishigami, Hideaki; Taida, Takashi; Okimoto, Kenichiro; Saito, Keiko; Maruoka, Daisuke; Matsumura, Tomoaki; Takizawa, Hirotaka; Kashiwado, Koichi; Kobayashi, Sohei; Matsushita, Kazuyuki; Matsubara, Hisahiro; Katsuno, Tatsuro; Arai, Makoto; Kato, Naoya

    2018-06-05

    The clinical course of ulcerative colitis (UC) is characterized by repeated episodes of relapse and remission. We hypothesized that biomarkers that help distinguish refractory UC patients who are in remission using strong anti-immunotherapy could contribute in preventing the overuse of corticosteroids for treatment. Here we clarified novel autoantibodies for UC patients in remission as clinical indicators to distinguish between refractory and non-refractory UC. Antigen proteins recognized by serum antibodies of patients with UC in remission were screened using the protein array method. To validate the results, AlphaLISA was used to analyze the serum antibody titers with candidate protein antigens. Serum samples from 101 healthy controls, 121 patients with UC, and 39 patients with Crohn's disease were analyzed. Of 66 candidate protein antigens screened by ProtoArray™, 6 were selected for this study. The serum titers of anti-poly ADP-ribose glycohydrolase (PARG), anti-transcription elongation factor A protein-like 1 (TCEAL1), and anti-proline-rich 13 (PRR13) antibodies were significantly higher in patients with UC than in healthy controls. Anti-PARG and anti-PRR13 antibody titers were significantly higher in patients with refractory UC than in patients with non-refractory UC. There were no significant differences in any antibody titer between the active and remission phases. The serum titers of anti-PARG, anti-TCEAL1, and anti-PRR13 antibodies were elevated in patients with UC. Anti-PARG and anti-PRR13 antibody titers may be novel clinical indicators for detecting refractory UC in patients in remission. This article is protected by copyright. All rights reserved.

  5. Current pesticide profiles in blood serum of adults in Jiangsu Province of China and a comparison with other countries.

    PubMed

    Chang, Chunxin; Chen, Minjian; Gao, Jiawei; Luo, Jia; Wu, Keqin; Dong, Tianyu; Zhou, Kun; He, Xiaowei; Hu, Weiyue; Wu, Wei; Lu, Chuncheng; Hang, Bo; Meeker, John D; Wang, Xinru; Xia, Yankai

    2017-05-01

    Although various pesticides were used globally, the pesticides profiles in human blood serum remain largely unknown. We determined pesticide exposure profiles using solid-phase extraction and gas chromatography tandem with triple quadrupole mass spectrometry in 200 human blood serum samples from the adult population in Jiangsu Province, China. A systematic and comprehensive literature review was carried out to identify the articles investigating pesticide exposure and compare exposure data. Of the 88 pesticides, 76 were found in the blood serum of the population in Jiangsu Province. To the best of our knowledge, 58 pesticides were reported in human blood serum for the first time, and among these pesticides, parathion-methyl, pyrimethanil, fluacrypyrim, simazine, cloquintocet-mexyl and barban were debatable in more than half of the samples. By statistical comparison of the blood serum levels of pesticides between this study and other countries, we found the levels of several organochlorine pesticides were significantly higher in the female population of Jiangsu Province. Health risks related to the pesticide profiling were then revealed, which identified higher carcinogenic toxicity and teratogenic toxicity risk in the female adults of Jiangsu Province caused by organochlorine pesticide exposure. This study not only provides a high-throughput pesticide screening method for future studies of the exposome, but also presents the first human data on exposure to a number of pesticides. It may provide a knowledge database for the risk assessment and management of the pesticides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Maternal serum alpha-fetoprotein at 12, 22 and 32 weeks' gestation in screening for pre-eclampsia.

    PubMed

    Bredaki, F E; Matalliotakis, M; Wright, A; Wright, D; Nicolaides, K H

    2016-04-01

    To examine the distribution of maternal serum alpha-fetoprotein (AFP) at 12, 22 and 32 weeks' gestation in singleton pregnancies which develop pre-eclampsia (PE) and examine the performance of this biomarker in screening for PE. Serum AFP was measured in 17 071 cases at 11-13 weeks, in 8583 cases at 19-24 weeks and 8609 cases at 30-34 weeks' gestation. Bayes' theorem was used to combine the a-priori risk from maternal characteristics and medical history with AFP. The performance of screening for PE requiring delivery < 32, at 32 + 0 to 36 + 6, < 37 and ≥ 37 weeks' gestation was estimated. In pregnancies that developed PE, serum AFP multiples of the median (MoM) was increased at 11-13 and 19-24 weeks' gestation, but not at 30-34 weeks, and the values were inversely related to gestational age at delivery. Combined screening with maternal factors and serum AFP improved the prediction provided by maternal factors alone for PE delivering < 37 weeks, but not for PE delivering ≥ 37 weeks. The performance of screening for preterm PE was better at 19-24 weeks than at 11-13 weeks and the detection rate (DR) for a given false-positive rate (FPR) was higher for PE delivering < 32 weeks than for PE delivering at 32 + 0 to 36 + 6 weeks. The DRs, at 10% FPR, of combined screening at 11-13 weeks for PE delivering < 32 and at 32 + 0 to 36 + 6 weeks were 54% and 45%, respectively, and these improved to 72% and 53% with screening at 19-24 weeks. Measurement of serum AFP at 11-13 and 19-24 weeks' gestation improves the prediction of preterm PE provided by maternal factors alone. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  7. Serum VEGFR-3 as a potential biomarker in psoriasis.

    PubMed

    Hong, Xia; Jiang, Shan; Marmolejo, Nancy; Vangipuram, Ramya; Ramos-Rojas, Elmira; Yuan, Yulin; Lin, Zuan-Tao; Li, Yaxi; Qiu, Jingyi; Xing, Yikun; Haley, Christopher; Tyring, Stephen K; Wu, Tianfu

    2018-06-29

    To discover novel biomarkers of psoriasis, a target-specific antibody array screening of serum samples from psoriasis patients was initially performed. The results revealed that Vascular endothelial growth factor receptor 3 (VEGFR-3) was significantly elevated in the sera of psoriasis patients, compared to healthy controls. Next, ELISA validation studies in a larger cohort of psoriasis patients (N=73) were conducted which confirmed that serum VEGFR-3 was indeed significantly increased in patients with psoriasis compared to healthy controls (P < 0.001). Furthermore, Receiver operating characteristic (ROC) curve analysis demonstrated that serum VEGFR-3 exhibited potential in distinguishing healthy controls from psoriasis patients: Area Under the Curve (AUC) = 0.85, P < 0.001. In addition, serum levels of VEGFR-3 were correlated with Psoriasis Area Severity Index (PASI) scores (R = 0.32, P = 0.008) in psoriasis patients. Interestingly, serum VEGFR-3 levels were significantly elevated in psoriatic arthritis compared to non-psoriatic arthritis (P = 0.026). A pilot longitudinal study demonstrated that serum levels of VEGFR-3 could reflect disease progression in psoriasis. Collectively, serum VEGFR-3 may have a clinical value in monitoring disease activity of psoriasis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Obstetrical complications associated with abnormal maternal serum markers analytes.

    PubMed

    Gagnon, Alain; Wilson, R Douglas

    2008-10-01

    To review the obstetrical outcomes associated with abnormally elevated or decreased level of one or more of the most frequently measured maternal serum marker analytes used in screening for aneuploidy. To provide guidance to facilitate the management of pregnancies that have abnormal levels of one of more markers and to assess the usefulness of these markers as a screening test. Perinatal outcomes associated with abnormal levels of maternal serum markers analytes are compared with the outcomes of pregnancies with normal levels of the same analytes or the general population. The Cochrane Library and Medline were searched for English-language articles published from 1966 to February 2007, relating to maternal serum markers and perinatal outcomes. Search terms included PAPP-A (pregnancy associated plasma protein A), AFP (alphafetoprotein), hCG (human chorionic gonadotropin), estriol, unconjugated estriol, inhibin, inhibin-A, maternal serum screen, triple marker screen, quadruple screen, integrated prenatal screen, first trimester screen, and combined prenatal screen. All study types were reviewed. Randomized controlled trials were considered evidence of the highest quality, followed by cohort studies. Key individual studies on which the recommendations are based are referenced. Supporting data for each recommendation are summarized with evaluative comments and references. The evidence was evaluated using the guidelines developed by the Canadian Task Force on Preventive Health Care. The evidence collected was reviewed by the Genetics Committee of the Society of Obstetricians and Gynaecologists of Canada. The benefit expected from this guideline is to facilitate early detection of potential adverse pregnancy outcomes when risks are identified at the time of a maternal serum screen. It will help further stratification of risk and provide options for pregnancy management to minimize the impact of pregnancy complications. The potential harms resulting from such practice are associated with the so called false positive (i.e., uncomplicated pregnancies labelled at increased risk for adverse perinatal outcomes), the potential stress associated with such a label, and the investigations performed for surveillance in this situation. No cost-benefit analysis is available to assess costs and savings associated with this guideline. SUMMARY STATEMENTS: 1. An unexplained level of a maternal serum marker analyte is defined as an abnormal level after confirmation of gestational age by ultrasound and exclusion of maternal, fetal, or placental causes for the abnormal level. (III) 2. Abnormally elevated levels of serum markers are associated with adverse pregnancy outcomes in twin pregnancies, after correction for the number of fetuses. Spontaneous or planned mutifetal reductions may result in abnormal elevations of serum markers. (II-2) RECOMMENDATIONS: 1. In the first trimester, an unexplained low PAPP-A (< 0.4 MoM) and/or a low hCG (< 0.5 MoM) are associated with an increased frequency of adverse obstetrical outcomes, and, at present, no specific protocol for treatment is available. (II-2A) In the second trimester, an unexplained elevation of maternal serum AFP (> 2.5 MoM), hCG (> 3.0 MoM), and/or inhibin-A (> or =2.0 MoM) or a decreased level of maternal serum AFP (< 0.25 MoM) and/or unconjugated estriol (< 0.5 MoM) are associated with an increased frequency of adverse obstetrical outcomes, and, at present, no specific protocol for treatment is available. (II-2A) 2. Pregnant woman with an unexplained elevated PAPP-A or hCG in the first trimester and an unexplained low hCG or inhibin-A and an unexplained elevated unconjugated estriol in the second trimester should receive normal antenatal care, as this pattern of analytes is not associated with adverse perinatal outcomes. (II-2A) 3. The combination of second or third trimester placenta previa and an unexplained elevated maternal serum AFP should increase the index of suspicion for placenta accreta, increta, or percreta. (II-2B) An assessment (ultrasound, MRI) of the placental-uterine interface should be performed. Abnormal invasion should be strongly suspected, and the planning of delivery location and technique should be done accordingly. (III-C) 4. A prenatal consultation with the medical genetics department is recommended for low unconjugated estriol levels (<0.3 MoM), as this analyte pattern can be associated with genetic conditions. (II-2B) 5. The clinical management protocol for identification of potential adverse obstetrical outcomes should be guided by one or more abnormal maternal serum marker analyte value rather than the false positive screening results for the trisomy 21 and/or the trisomy 18 screen. (II-2B) 6. Pregnant woman who are undergoing renal dialysis or who have had a renal transplant should be offered maternal serum screening, but interpretation of the result is difficult as the level of serum hCG is not reliable. (II-2A) 7. Abnormal maternal uterine artery Doppler in association with elevated maternal serum AFP, hCG, or inhibin-A or decreased PAPP-A identifies a group of women at greater risk of IUGR and gestational hypertension with proteinuria. Uterine artery Doppler measurements may be used in the evaluation of an unexplained abnormal level of either of these markers. (II-2B) 8. Further research is recommended to identify the best protocol for pregnancy management and surveillance in women identified at increased risk of adverse pregnancy outcomes based on an abnormality of a maternal serum screening analyte. (III-A) 9. In the absence of evidence supporting any specific surveillance protocol, an obstetrician should be consulted in order to establish a fetal surveillance plan specific to the increased obstetrical risks (maternal and fetal) identified. This plan may include enhanced patient education on signs and symptoms of the most common complications, increased frequency of antenatal visits, increased ultrasound (fetal growth, amniotic fluid levels), and fetal surveillance (biophysical profile, arterial and venous Doppler), and cervical length assessment. (III-A) 10. Limited information suggests that, in women with elevated hCG in the second trimester and/or abnormal uterine artery Doppler (at 22-24 weeks), low-dose aspirin (60-81 mg daily) is associated with higher birthweight and lower incidence of gestational hypertension with proteinuria. This therapy may be used in women who are at risk. (II-2B) 11. Further studies are recommended in order to assess the benefits of low-dose aspirin, low molecular weight heparin, or other therapeutic options in pregnancies determined to be at increased risk on the basis of an abnormal maternal serum screening analyte. (III-A) 12. Multiple maternal serum markers screening should not be used at present as a population-based screening method for adverse pregnancy outcomes (such as preeclampsia, placental abruption, and stillbirth) outside an established research protocol, as sensitivity is low, false positive rates are high, and no management protocol has been shown to clearly improve outcomes. (II-2D) When maternal serum screening is performed for the usual clinical indication (fetal aneuploidy and/or neural tube defect), abnormal analyte results can be utilized for the identification of pregnancies at risk and to direct their clinical management. (II-2B) Further studies are recommended to determine the optimal screening method for poor maternal and/or perinatal outcomes. (III-A).

  9. Prospective evaluation of 64 serum autoantibodies as biomarkers for early detection of colorectal cancer in a true screening setting.

    PubMed

    Chen, Hongda; Werner, Simone; Butt, Julia; Zörnig, Inka; Knebel, Phillip; Michel, Angelika; Eichmüller, Stefan B; Jäger, Dirk; Waterboer, Tim; Pawlita, Michael; Brenner, Hermann

    2016-03-29

    Novel blood-based screening tests are strongly desirable for early detection of colorectal cancer (CRC). We aimed to identify and evaluate autoantibodies against tumor-associated antigens as biomarkers for early detection of CRC. 380 clinically identified CRC patients and samples of participants with selected findings from a cohort of screening colonoscopy participants in 2005-2013 (N=6826) were included in this analysis. Sixty-four serum autoantibody markers were measured by multiplex bead-based serological assays. A two-step approach with selection of biomarkers in a training set, and validation of findings in a validation set, the latter exclusively including participants from the screening setting, was applied. Anti-MAGEA4 exhibited the highest sensitivity for detecting early stage CRC and advanced adenoma. Multi-marker combinations substantially increased sensitivity at the price of a moderate loss of specificity. Anti-TP53, anti-IMPDH2, anti-MDM2 and anti-MAGEA4 were consistently included in the best-performing 4-, 5-, and 6-marker combinations. This four-marker panel yielded a sensitivity of 26% (95% CI, 13-45%) for early stage CRC at a specificity of 90% (95% CI, 83-94%) in the validation set. Notably, it also detected 20% (95% CI, 13-29%) of advanced adenomas. Taken together, the identified biomarkers could contribute to the development of a useful multi-marker blood-based test for CRC early detection.

  10. High-throughput sequencing enhanced phage display enables the identification of patient-specific epitope motifs in serum.

    PubMed

    Christiansen, Anders; Kringelum, Jens V; Hansen, Christian S; Bøgh, Katrine L; Sullivan, Eric; Patel, Jigar; Rigby, Neil M; Eiwegger, Thomas; Szépfalusi, Zsolt; de Masi, Federico; Nielsen, Morten; Lund, Ole; Dufva, Martin

    2015-08-06

    Phage display is a prominent screening technique with a multitude of applications including therapeutic antibody development and mapping of antigen epitopes. In this study, phages were selected based on their interaction with patient serum and exhaustively characterised by high-throughput sequencing. A bioinformatics approach was developed in order to identify peptide motifs of interest based on clustering and contrasting to control samples. Comparison of patient and control samples confirmed a major issue in phage display, namely the selection of unspecific peptides. The potential of the bioinformatic approach was demonstrated by identifying epitopes of a prominent peanut allergen, Ara h 1, in sera from patients with severe peanut allergy. The identified epitopes were confirmed by high-density peptide micro-arrays. The present study demonstrates that high-throughput sequencing can empower phage display by (i) enabling the analysis of complex biological samples, (ii) circumventing the traditional laborious picking and functional testing of individual phage clones and (iii) reducing the number of selection rounds.

  11. A Rational Approach for Discovering and Validating Cancer Markers in Very Small Samples Using Mass Spectrometry and ELISA Microarrays

    DOE PAGES

    Zangar, Richard C.; Varnum, Susan M.; Covington, Chandice Y.; ...

    2004-01-01

    Identifying useful markers of cancer can be problematic due to limited amounts of sample. Some samples such as nipple aspirate fluid (NAF) or early-stage tumors are inherently small. Other samples such as serum are collected in larger volumes but archives of these samples are very valuable and only small amounts of each sample may be available for a single study. Also, given the diverse nature of cancer and the inherent variability in individual protein levels, it seems likely that the best approach to screen for cancer will be to determine the profile of a battery of proteins. As a result,more » a major challenge in identifying protein markers of disease is the ability to screen many proteins using very small amounts of sample. In this review, we outline some technological advances in proteomics that greatly advance this capability. Specifically, we propose a strategy for identifying markers of breast cancer in NAF that utilizes mass spectrometry (MS) to simultaneously screen hundreds or thousands of proteins in each sample. The best potential markers identified by the MS analysis can then be extensively characterized using an ELISA microarray assay. Because the microarray analysis is quantitative and large numbers of samples can be efficiently analyzed, this approach offers the ability to rapidly assess a battery of selected proteins in a manner that is directly relevant to traditional clinical assays.« less

  12. Utility of Decision Rules for Transcutaneous Bilirubin Measurements

    PubMed Central

    Burgos, Anthony E.; Flaherman, Valerie; Chung, Esther K.; Simpson, Elizabeth A.; Goyal, Neera K.; Von Kohorn, Isabelle; Dhepyasuwan, Niramol

    2016-01-01

    BACKGROUND: Transcutaneous bilirubin (TcB) meters are widely used for screening newborns for jaundice, with a total serum bilirubin (TSB) measurement indicated when the TcB value is classified as “positive” by using a decision rule. The goal of our study was to assess the clinical utility of 3 recommended TcB screening decision rules. METHODS: Paired TcB/TSB measurements were collected at 34 newborn nursery sites. At 27 sites (sample 1), newborns were routinely screened with a TcB measurement. For sample 2, sites that typically screen with TSB levels also obtained a TcB measurement for the study. Three decision rules to define a positive TcB measurement were evaluated: ≥75th percentile on the Bhutani nomogram, 70% of the phototherapy level, and within 3 mg/dL of the phototherapy threshold. The primary outcome was a TSB level at/above the phototherapy threshold. The rate of false-negative TcB screens and percentage of blood draws avoided were calculated for each decision rule. RESULTS: For sample 1, data were analyzed on 911 paired TcB-TSB measurements from a total of 8316 TcB measurements. False-negative rates were <10% with all decision rules; none identified all 31 newborns with a TSB level at/above the phototherapy threshold. The percentage of blood draws avoided ranged from 79.4% to 90.7%. In sample 2, each rule correctly identified all 8 newborns with TSB levels at/above the phototherapy threshold. CONCLUSIONS: Although all of the decision rules can be used effectively to screen newborns for jaundice, each will “miss” some infants with a TSB level at/above the phototherapy threshold. PMID:27244792

  13. Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples.

    PubMed

    Castro, Andréa Cauduro de; Borges, Luiz Gustavo dos Anjos; Souza, Ricardo da Silva de; Grudzinski, Melina; D'Azevedo, Pedro Alves

    2008-01-01

    Human Immunodeficiency Virus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and immunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS-Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 degrees C, -20 degrees C and -70 degrees C, while the second was composed of two negative and three positive samples stored at 37 degrees C (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.

  14. Newborn Screening Guidelines for Congenital Hypothyroidism in India: Recommendations of the Indian Society for Pediatric and Adolescent Endocrinology (ISPAE) - Part II: Imaging, Treatment and Follow-up.

    PubMed

    Sudhanshu, S; Riaz, I; Sharma, R; Desai, M P; Parikh, R; Bhatia, V

    2018-06-01

    The Indian Society for Pediatric and Adolescent Endocrinology has formulated Clinical Practice Guidelines for newborn screening, diagnosis and management of congenital hypothyroidism (CH). This manuscript, part II addresses management and follow-up. Screening should be done for every newborn using cord blood, or postnatal blood ideally at 48 to 72 h of age. Neonates with screen TSH > 20 mIU/L serum units (or >34 mIU/L for samples taken between 24 and 48 h of age) should be recalled for confirmation. For screen TSH > 40 mIU/L, immediate confirmatory venous T4/FT4 and TSH, and for mildly elevated screen TSH, a second screening TSH at 7 to 10 d of age, should be taken. Preterm and low birth weight infants should undergo screening at 48-72 h age. Sick babies should be screened at least by 7 d of age. Venous confirmatory TSH >20 mIU/L before age 2 wk and >10 mIU/L after age 2 wk, with low T4 (<10 μg/dL) or FT4 (<1.17 ng/dL) indicate primary CH and treatment initiation. Imaging is recommended by radionuclide scintigraphy and ultrasonography after CH is biochemically confirmed but treatment should not be delayed till scans are performed. Levothyroxine is commenced at 10-15 μg/kg in the neonatal period. Serum T4/FT4 is measured at 2 wk and TSH and T4/FT4 at 1 mo, then 2 monthly till 6 mo, 3 monthly from 6 mo-3 y and every 3-6 mo thereafter. Babies with the possibility of transient CH should be re-evaluated at age 3 y, to assess the need for lifelong therapy.

  15. Micro-bead injection spectroscopy for label-free automated determination of immunoglobulin G in human serum.

    PubMed

    Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A

    2018-01-01

    Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were < 9.4 and < 11.7%, for intra and inter-assay precision, respectively, while recovery values for human serum spiked with IgG at high pathological levels were 97.8-101.4%. Comparison to commercial ELISA kit showed no significant difference for tested samples (n = 8). Moreover, time-to-result decreased from several hours to < 5 min and analysis cost decreased 10 times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.

  16. Seroprevalence of Capripoxvirus infection in sheep and goats among different agro-climatic zones of Odisha, India

    PubMed Central

    Hota, Abhishek; Biswal, Sangram; Sahoo, Niranjana; Venkatesan, Gnanavel; Arya, Sargam; Kumar, Amit; Ramakrishnan, Muthannan Andavar; Pandey, Awadh Bihari; Rout, Manoranjan

    2018-01-01

    Aim: The study was undertaken to assess the prevalence of antibodies to Capripoxviruses among small ruminants of Odisha, India. Materials and Methods: A total of 500 random serum samples collected from 214 sheep and 286 goats across 10 agro-climatic zones of Odisha, were screened using whole virus antigen-based indirect ELISA for antibodies against Capripoxviruses. Results were analyzed by suitable statistical methods. Results: Screening of 500 serum samples showed seropositivity of 8.88% and 31.47% in sheep and goats, respectively, for Capripoxviruses. The prevalence rate according to agro-climatic zone ranged from 0% (North Eastern coastal plain zone) to 48.57% (North central plateau zone) for goat pox, and 0% (Western undulating zone and North central plateau) to 22.22% (South Eastern ghat zone) for sheep pox. The difference in prevalence rates among the various agro-climatic zones was statistically significant (p<0.05) for goats, but not for sheep. Antibody prevalence rates among various districts were recorded to be the highest in Jagatsinghpur (30%) for sheep pox and Dhenkanal (80%) for goat pox. Conclusions: The study revealed serological evidence of Capripoxvirus infection in sheep and goat populations in the study area, in the absence of vaccination. Systematic investigation, monitoring, and reporting of outbreaks are necessary to devise control strategies. PMID:29479159

  17. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    PubMed

    Yang, Ruiyue; Dong, Jun; Guo, Hanbang; Li, Hongxia; Wang, Shu; Zhao, Haijian; Zhou, Weiyan; Yu, Songlin; Wang, Mo; Chen, Wenxiang

    2013-01-01

    Serum branched-chain and aromatic amino acids (BCAAs and AAAs) have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  18. Diagnosis of cysticercosis in endemic regions. The Cysticercosis Working Group in Peru.

    PubMed

    Garcia, H H; Martinez, M; Gilman, R; Herrera, G; Tsang, V C; Pilcher, J B; Diaz, F; Verastegui, M; Gallo, C; Porras, M

    1991-08-31

    Taenia solium cysticercosis is a frequent cause of neurological disease in developing countries. Specific diagnosis of cysticercosis is difficult. We obtained serum and/or CSF samples from 204 consecutive patients admitted to a neurological ward in Lima, Peru, and looked for antibodies specific for T solium with the enzyme-linked immunoelectrotransfer blot (EITB) assay. 21 (12%) of 173 serum samples from these patients were EITB-positive. In contrast, only 2 (1.5%) of 135 patients attending a public endoscopy clinic and 1 (1%) of 88 patients attending a private endoscopy clinic were seropositive. 1 (1%) of 98 pregnant women living in a Lima shanty town was EITB-positive. 15 (58%) of 26 neurology patients diagnosed clinically as having cysticercosis were seronegative. Routine screening by EITB of all patients with neurological symptoms from areas of endemic cysticercosis would avoid misdiagnosis of this common and treatable disease.

  19. Diagnosis of cysticercosis in endemic regions

    PubMed Central

    Garcia, H. H.; Martinez, M.; Gilman, R.; Herrera, G.; Tsang, V. C. W.; Pilcher, J. B.; Diaz, F.; Verastegui, M.; Gallo, C.; Porras, M.; Alvarado, M.; Naranjo, J.; Miranda, E.

    2010-01-01

    Taenia solium cysticercosis is a frequent cause of neurological disease in developing countries. Specific diagnosis of cysticercosis is difficult. We obtained serum and/or CSF samples from 204 consecutive patients admitted to a neurological ward in Lima, Peru, and looked for antibodies specific for T solium with the enzyme-linked immunoelectrotransfer blot (EITB) assay. 21 (12%) of 173 serum samples from these patients were EITB-positive. In contrast only 2 (1·5%) of 135 patients attending a public endoscopy clinic and 1 (1%) of 88 patients attending a private endoscopy clinic were seropositive. 1 (1%) of 98 pregnant women living in a Lima shanty town was EITB-positive. 15 (58%) of 26 neurology patients diagnosed clinically as having cysticercosis were seronegative. Routine screening by EITB of all patients with neurological symptoms from areas of endemic cysticercosis would avoid misdiagnosis of this common and treatable disease. PMID:1678809

  20. Relationship between high serum ferritin level and glaucoma in a South Korean population: the Kangbuk Samsung health study.

    PubMed

    Gye, Hyo Jung; Kim, Joon Mo; Yoo, Chungkwon; Shim, Seong Hee; Won, Yu Sam; Sung, Ki Chul; Lee, Mi Yeon; Park, Ki Ho

    2016-12-01

    To investigate the association between serum ferritin levels and glaucoma in a South Korean population. This retrospective cross-sectional study included 164 029 subjects who underwent screening at Kangbuk Samsung Hospital Health Screening Center between August 2012 and July 2013. All subjects underwent a physical examination, answered sociodemographic and behavioural questions, and provided samples for laboratory analyses. A digital fundus photograph of both eyes was taken, and all photographs were reviewed by ophthalmologists. The ophthalmologists determined if an eye had glaucoma based on criteria set forth by the International Society of Geographical and Epidemiological Ophthalmology and the appearance of the retinal nerve fibre layer and optic disc. The mean serum ferritin level was 56.98 ng/mL in women and 223.82 ng/mL in men. After adjusting for age, serum iron, total iron-binding capacity (TIBC), transferrin saturation, white blood cell (WBC) count, high-sensitivity C-reactive protein (HsCRP) and total vitamin D level, males in the highest quartile for serum ferritin level had a higher OR for glaucoma than males in the lowest quartile (OR=1.176, 95% CI 1.030 to 1.342, p=0.016); we did not observe this relationship among women. Other markers of iron metabolism, such as iron level, transferrin saturation and TIBC, and inflammation measures, including WBC, HsCRP and total vitamin D, were not associated with glaucoma. High serum ferritin level was associated with a high risk of glaucoma in men, but not in women. Because serum ferritin is related to oxidative stress and inflammation, it might play a role in glaucoma development. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. 3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray.

    PubMed

    Kadimisetty, Karteek; Mosa, Islam M; Malla, Spundana; Satterwhite-Warden, Jennifer E; Kuhns, Tyler M; Faria, Ronaldo C; Lee, Norman H; Rusling, James F

    2016-03-15

    Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)3(2+) (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300-500f gmL(-1) for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. First Trimester Urine and Serum Metabolomics for Prediction of Preeclampsia and Gestational Hypertension: A Prospective Screening Study.

    PubMed

    Austdal, Marie; Tangerås, Line H; Skråstad, Ragnhild B; Salvesen, Kjell; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone F

    2015-09-08

    Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension). Preeclampsia developed in 26 (4.3%) and gestational hypertension in 21 (3.5%) women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.

  3. Rapid screening of methamphetamines in human serum by headspace solid-phase microextraction using a dodecylsulfate-doped polypyrrole film coupled to ion mobility spectrometry.

    PubMed

    Alizadeh, Naader; Mohammadi, Abdorreza; Tabrizchi, Mahmoud

    2008-03-07

    A simple, rapid and highly sensitive method for simultaneous analysis of methamphetamine (MA) and 3,4-methylenedioxy methamphetamine (MDMA) in human serum was developed using the solid-phase microextraction (SPME) combined with ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS) was applied as a new fiber for SPME. Electrochemically polymerized PPy is formed on the surface of a platinum wire and will contain charge-compensating anion (dodecylsulfate) incorporated during synthesis using cyclic voltammetry (CV) technique. The extraction properties of the fiber to MA and MDMA were examined, using a headspace-SPME (HS-SPME) device and thermal desorption in injection port of IMS. The results show that PPy-DS as a SPME fiber coating is suitable for the successful extraction of these compounds. This method is suitable for the identification and determination of MAs, is not time-consuming, requires small quantities of sample and does not require any derivatization. Parameters like pH, extraction time, ionic strength, and temperature of the sample were studied and optimized to obtain the best extraction results. The HS-SPME-IMS method provided good repeatability (RSDs<7.8 %) for spiked serum samples. The calibration graphs were linear in the range of 20-4000 ng ml(-1) (R(2)>0.99) and detection limits for MDMA and MA were 5 and 8 ng ml(-1), respectively. HS-SPME-IMS of non-spiked serum sample provided a spectrum without any peak from the matrix, supporting an effective sample clean-up. Finally, the proposed method was applied for analysis one of the ecstasy tablet.

  4. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  5. Serum metabolomics differentiating pancreatic cancer from new-onset diabetes

    PubMed Central

    He, Xiangyi; Zhong, Jie; Wang, Shuwei; Zhou, Yufen; Wang, Lei; Zhang, Yongping; Yuan, Yaozong

    2017-01-01

    To establish a screening strategy for pancreatic cancer (PC) based on new-onset diabetic mellitus (NO-DM), serum metabolomics analysis and a search for the metabolic pathways associated with PC related DM were performed. Serum samples from patients with NO-DM (n = 30) and patients with pancreatic cancer and NO-DM were examined by liquid chromatography-mass spectrometry. Data were analyzed using principal components analysis (PCA) and orthogonal projection to latent structures (OPLS) of the most significant metabolites. The diagnostic model was constructed using logistic regression analysis. Metabolic pathways were analyzed using the web-based tool MetPA. PC patients with NO-DM were older and had a lower BMI and shorter duration of DM than those with NO-DM. The metabolomic profiles of patients with PC and NO-DM were significantly different from those of patients with NO-DM in the PCA and OPLS models. Sixty two differential metabolites were identified by the OPLS model. The logistic regression model using a panel of two metabolites including N_Succinyl_L_diaminopimelic_acid and PE (18:2) had high sensitivity (93.3%) and specificity (93.1%) for PC. The top three metabolic pathways associated with PC related DM were valine, leucine and isoleucine biosynthesis and degradation, primary bile acid biosynthesis, and sphingolipid metabolism. In conclusion, screening for PC based on NO-DM using serum metabolomics in combination with clinic characteristics and CA19-9 is a potential useful strategy. Several metabolic pathways differed between PC related DM and type 2 DM. PMID:28418859

  6. Inverse Association between Vitamin D Status and Diabetes in a Clinic Based Sample of Hispanic Adults in Puerto Rico.

    PubMed

    Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M; Palacios, Cristina

    2015-04-01

    Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12-20 ng/ml); insufficient (21-29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels.

  7. Inverse Association between Vitamin D Status and Diabetes in a Clinic Based Sample of Hispanic Adults in Puerto Rico

    PubMed Central

    Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M.; Palacios, Cristina

    2017-01-01

    Background Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Methods Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12–20 ng/ml); insufficient (21–29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. Results A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Conclusion Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels. PMID:28345061

  8. Reduction of novel circulating long-chain fatty acids in colorectal cancer patients is independent of tumor burden and correlates with age

    PubMed Central

    2010-01-01

    Background Serum levels of novel hydroxy polyunsaturated ultra long-chain fatty acids (hPULCFAs) have been previously shown to be reduced in pre-treatment CRC patients compared to disease-free subjects, independent of disease stage. However, whether reduced levels of hPULCFAs result from the presence of cancer is currently unknown, as is the distribution of hPULCFAs in the general population. The following studies were carried out to assess whether conventional therapy would result in restoration of systemic hPULCFAs in CRC patients, and to investigate the relationship between hPULCFA levels and age. Methods Tandem mass spectrometry was used to determine serum levels of the 28 carbon-containing hPULCFA C28H46O4 (CRC-446) in the following cohorts: two independent Japanese CRC populations following surgical tumor removal (n = 86), a North American Caucasian CRC cohort (n = 150) following post-surgery combination chemo/radiation therapy, 990 randomly selected anonymized serum samples from subjects ranging between 11 and 99 years of age, as well as longitudinally collected serum samples from healthy normals (n = 8, up to 90 weeks) and stage IV CRC subjects on combination therapy (n = 12, up to 63 weeks). Results Serum CRC-446 levels in CRC subjects were significantly lower than controls (mean of 0.297 ± 0.07 ug/ml in controls versus 0.092 ± 0.03 in CRCs, p < 0.001), and were unaffected by surgical tumor removal or by chemo/radiation treatment (p > 0.05 between pre vs post surgery). CRC-446 levels showed a strong inverse association with age (p < E-11) across the randomly-selected cohort of 990 subjects, with no correlation observed in the CRC-positive subjects. Longitudinal intra-subject results, however, showed relatively stable CRC-446 levels over the short term of up to 90 weeks in both disease-free subjects and late-stage CRC patients. Conclusions Our findings show that CRC-446 levels are not affected by conventional CRC treatment and inversely correlate with age, which suggest that reduced serum CRC-446 levels likely exist prior to the development of CRC. Extrapolation of the results to a simple screening scenario showed that, compared to fecal blood testing, pre-colonoscopy screening using serum CRC-446 levels would require 80% fewer colonoscopies, would identify risk in subjects under the age of 50, and would result in increased numbers of early cases detected. The precise role these serum metabolites play in the aetiology of cancer development remains to be determined. PMID:21114854

  9. Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking.

    PubMed

    Choi, Eun-Hye; Lee, Sang Kwang; Ihm, Chunhwa; Sohn, Young-Hak

    2014-12-01

    Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. The purpose of this study was to compare the quality, purity, and quantity of DNA isolated from frozen blood samples and DBSs. We optimized a method for extraction and estimation of DNA from blood spots dried on filter paper (3-mm FTA card). A single DBS containing 40 μL blood was used. DNA was efficiently extracted in phosphate-buffered saline (PBS) or Tris-EDTA (TE) buffer by incubation at 37°C overnight. DNA was stable in DBSs that were stored at room temperature or frozen. The housekeeping genes GAPDH and beta-actin were used as positive standards for polymerase chain reaction (PCR) validation of general diagnostic screening. Our simple and convenient DBS storage and extraction methods are suitable for diagnostic screening by using very small volumes of blood collected on filter paper, and can be used in biobanks for blood sample storage.

  10. Variability in assays used for detection of lentiviral infection in bobcats (Lynx rufus), pumas (Puma concolor), and ocelots (Leopardus pardalis)

    USGS Publications Warehouse

    Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.

    2007-01-01

    Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.

  11. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    PubMed

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  12. Seroprevalence of parvovirus B19 antibodies and evidence of viremia among Nigerian patients with sickle cell anemia.

    PubMed

    Iwalokun, Bamidele Abiodun; Iwalokun, Senapon Olusola; Hodonu, Semande Olufunmilayo

    2013-07-01

    Clinical, biochemical and molecular evidence for the sickle cell anemia (SCA) crisis in Nigerian patients arising from parvovirus b19 infection remains inadequate. This study determined the prevalence and correlates of anti-parvovirus b19 antibodies in a population of SCA patients and non-SCA healthy controls in Lagos, Nigeria. In this prospective cross-sectional study, we enrolled 73 confirmed SCA patients from 5 district hospitals in Lagos and 81 sex and age-matched non-SCA healthy controls. Serum sample from each study participant was screened for anti-parvovirus b19 by ELISA and PCR techniques. Standard biomedical assays were also done. Anti-parvovirus b19 IgM and IgG antibodies were detected in 22 (14.3%) and 97 (62.9%) of the 154 sera screened, 13 (17.8%) and 45 (61.6%) in SCA patients; 9 (11.1%) and 52 (64.2%) in non-SCA controls. The overall seronegativity rate was 19.5%. Parvovirus B19 DNA was found in 2 (11.1%) of the 18 IgM seropositive SCA serum samples screened. On the whole, parvovirus b19 infection was more commonly asymptomatic in non-SCA controls but caused significant elevation in liver enzymes in infected SCA patients (P < 0.05). The risk of acute parvovirus b19 infection increased 65 times during unsteady state among the SCA patients. Although no deaths of infected patients were recorded during the study, age below 12 years, hospitalization and overcrowded environment were risk factors for infection. We conclude that parvovirus b19 is common in SCA patients, incurring greater susceptibility to infections.

  13. [User's requests (from a practitioner's perspective)].

    PubMed

    Ohnishi, T

    1997-08-01

    As a practitioner, I have to rely on outside clinical laboratories and affiliated hospitals to perform laboratory tests. In this abstract, I describe specific problems I have encountered with third-party laboratories, and propose solutions for these problems to optimize use of laboratory tests. BLOOD TESTS: The most frequent problem in ordering blood tests is the lack of detailed information regarding sampling conditions. I often have to call laboratories to check whether the sample should be serum or plasma, what volume is needed, whether the sample should be cooled, etc. I propose that clinical laboratories should provide practitioners' manuals that describe specific sampling information. Most laboratories do not keep the data from ultrasonographic tests. The lack of these is most problematic when test results are interpreted differently by laboratories and by practitioners. Retaining the data would also help private laboratories improve the quality of the test by enabling them to compare their interpretations with others'. ANNUAL MEDICAL SCREENING: Even if an abnormal finding is detected at medical screening clinics, the final diagnosis is usually not sent back to the screening facilities. This is highly recommended to establish an official system that mediates the feedback to screening centers. MRI: Due to miscommunication between practitioners and radiologists, the test is sometimes performed inappropriately. A thorough consultation should occur before the test to clarify specific goals for each patient. PATHOLOGICAL TESTS: Interpretation of results is often inconsistent among laboratories. Independent clinical laboratories tend to report results without indicating sample problems, while pathology departments at affiliated hospitals tend to emphasize sample problems instead of diagnosis or suggesting ways to improve sample quality. Mutual communication among laboratories would help standardize the quality of pathological tests.

  14. Screening for antibody to HTLV-III in blood donors of Liguria. Ligurian Committee for the Study of Infections Transmitted through Blood and Blood Products.

    PubMed

    1985-01-01

    Anti-HTLV III had been detected in 12,689 serum samples collected within August 1985 from 12 Transfusion Centres of Liguria. In the course of the first test, carried out by ELISA using disrupted virions as antigen, 12,666 samples (99.81%) resulted non reactive; 14 (0.1%) belonged to the grey-zone and 9 (0.08%) were clearly reactive. The samples of the last two classes were tested again in the same way and, whenever the cases were suspect as positive, by Western-blot technique. All positive cases, but three, were linked with risk factors such as intravenous drug use or drug addicts partners. Even if the prevalence of blood donors anti-HTLV III positive resulted, on the whole, very low (0.063%), the investigations carried out prove the importance of regular screening of blood units for the prevention of HTLV III infection.

  15. Association between serum cholesterol and eating behaviours during early childhood: a cross-sectional study.

    PubMed

    Persaud, Navindra; Maguire, Jonathon L; Lebovic, Gerald; Carsley, Sarah; Khovratovich, Marina; Randall Simpson, Janis A; McCrindle, Brian W; Parkin, Patricia C; Birken, Catherine

    2013-08-06

    Modifiable behaviours during early childhood may provide opportunities to prevent disease processes before adverse outcomes occur. Our objective was to determine whether young children's eating behaviours were associated with increased risk of cardiovascular disease in later life. In this cross-sectional study involving children aged 3-5 years recruited from 7 primary care practices in Toronto, Ontario, we assessed the relation between eating behaviours as assessed by the NutriSTEP (Nutritional Screening Tool for Every Preschooler) questionnaire (completed by parents) and serum levels of non-high-density lipoprotein (HDL) cholesterol, a surrogate marker of cardiovascular risk. We also assessed the relation between dietary intake and serum non-HDL cholesterol, and between eating behaviours and other laboratory indices of cardiovascular risk (low-density lipoprotein [LDL] cholesterol, apolipoprotein B, HDL cholesterol and apoliprotein A1). A total of 1856 children were recruited from primary care practices in Toronto. Of these children, we included 1076 in our study for whom complete data and blood samples were available for analysis. The eating behaviours subscore of the NutriSTEP tool was significantly associated with serum non-HDL cholesterol (p = 0.03); for each unit increase in the eating behaviours subscore suggesting greater nutritional risk, we saw an increase of 0.02 mmol/L (95% confidence interval [CI] 0.002 to 0.05) in serum non-HDL cholesterol. The eating behaviours subscore was also associated with LDL cholesterol and apolipoprotein B, but not with HDL cholesterol or apolipoprotein A1. The dietary intake subscore was not associated with non-HDL cholesterol. Eating behaviours in preschool-aged children are important potentially modifiable determinants of cardiovascular risk and should be a focus for future studies of screening and behavioural interventions.

  16. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  17. Occurrence of retained placenta is preceded by an inflammatory state and alterations of energy metabolism in transition dairy cows.

    PubMed

    Dervishi, Elda; Zhang, Guanshi; Hailemariam, Dagnachew; Dunn, Suzana M; Ametaj, Burim N

    2016-01-01

    Failure to expel fetal membranes within 24 h of calving is a pathological condition defined as retained placenta (RP). The objective of this investigation was to evaluate whether there are alterations in several selected serum variables related to innate immunity and carbohydrate and lipid metabolism that precede occurrence of RP in transition Holstein dairy cows. One hundred multiparous Holstein dairy cows were involved in the study. Blood samples were collected from the coccygeal vein during the -8 to +4 wks around parturition, once per week before the morning feeding. Six healthy control cows (CON) and 6 cows with RP were selected and serum samples at -8, -4, time of diagnosis of disease, and +4 wks relative to parturition were used for analyses. All samples were analyzed for lactate, non-esterified fatty acids (NEFA), β-hydroxybutyrate (BHBA), interleukin-1 (IL-1), interleukin-6 (IL-6), tumor necrosis factor (TNF), haptoglobin (Hp), and serum amyloid A (SAA). Cows with RP had greater concentrations of serum lactate, IL-1, IL-6, TNF, and SAA in comparison with CON cows. Intriguingly, elevated concentrations of all five variables were observed at -8 and -4 wks before the occurrence of RP compared to healthy cows. Cows with RP also had lower DMI and milk production vs CON animals; however milk composition was not affected by RP. Cows with RP showed an activated innate immunity 8 wks prior to diagnosis of disease. Overall results suggest that serum IL-1, IL- 6, and TNF, and lactate can be used as screening biomarkers to indicate cows that might have health issues during the transition period.

  18. Second Trimester Maternal Serum Screening for Fetal Down Syndrome: as a Screening Test for Hemoglobin Bart's Disease: A Prospective Population-based Study.

    PubMed

    Wanapirak, Chanane; Piyamomgkol, Wirawit; Sirichotiyakul, Supatra; Tongprasert, Fuanglada; Srisupundit, Kasemsri; Luewan, Suchaya; Traisrisilp, Kuntharee; Jatavan, Phudit; Tongsong, Theera

    2018-06-21

    To determine the effectiveness of second-trimester maternal serum screening (MSS) for Down syndrome as a screening test for fetal hemoglobin (Hb) Bart's disease among an unselected population. A secondary analysis of a large prospective database (20,254 pregnancies) was conducted to compare the levels of MSS, alpha-fetoprotein (AFP), free beta-human chorionic gonadotropin (hCG) and unconjugated estriol (uE3) between pregnancies with Hb Bart's disease and unaffected pregnancies. The median AFP levels were much higher among affected fetuses, (1.96 vs. 1.12 multiple of the median (MoM); p<0.001), yielding a sensitivity of 81.6% and specificity of 86.4%. Thus, AFP measurement is effective in predicting fetal Hb Bart's disease among an unselected population when using a cut-off value of 1.5 MoM. The serum free b-hCG levels were slightly, but significantly, higher in the affected pregnancies, while the serum uE3 levels were minimally, but significantly, lower among the affected pregnancies. Second trimester maternal serum AFP levels were significantly elevated in cases of fetal Hb Bart's disease. Pregnancies with unexplained elevated serum AFP levels in areas of high prevalence of Hb Bart's disease should always undergo a detailed ultrasound examination to detect any early signs of fetal anemia before development of hydrops fetalis. This article is protected by copyright. All rights reserved.

  19. Use of radioimmunoassay as a screen for antibiotics in confined animal feeding operations and confirmation by liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.

    2000-01-01

    Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid chromatography/mass spectrometry concentrations for chlorotetracycline. Copyright (C) 2000 Elsevier Science B.V.

  20. Second-trimester maternal serum marker screening: maternal serum alpha-fetoprotein, beta-human chorionic gonadotropin, estriol, and their various combinations as predictors of pregnancy outcome.

    PubMed

    Yaron, Y; Cherry, M; Kramer, R L; O'Brien, J E; Hallak, M; Johnson, M P; Evans, M I

    1999-10-01

    We evaluated the value of all 3 common biochemical serum markers, maternal serum alpha-fetoprotein, beta-human chorionic gonadotropin, and unconjugated estriol, and combinations thereof as predictors of pregnancy outcome. A total of 60,040 patients underwent maternal serum screening. All patients had maternal serum alpha-fetoprotein measurements; beta-human chorionic gonadotropin was measured in 45,565 patients, and 24,504 patients had determination of all 3 markers, including unconjugated estriol. The incidences of various pregnancy outcomes were evaluated according to the serum marker levels by using clinically applied cutoff points. In confirmation of previous observations, increased maternal serum alpha-fetoprotein levels (>2.5 multiples of the median) were found to be significantly associated with pregnancy-induced hypertension, miscarriage, preterm delivery, intrauterine growth restriction, intrauterine fetal death, oligohydramnios, and abruptio placentae. Increased beta-human chorionic gonadotropin levels (>2.5 multiples of the median [MoM]) were significantly associated with pregnancy-induced hypertension, miscarriage, preterm delivery, and intrauterine fetal death. Finally, decreased unconjugated estriol levels (<0.5 MoM) were found to be significantly associated with pregnancy-induced hypertension, miscarriage, intrauterine growth restriction, and intrauterine fetal death. As with increased second-trimester maternal serum alpha-fetoprotein levels, increased serum beta-human chorionic gonadotropin and low unconjugated estriol levels are significantly associated with adverse pregnancy outcomes. These are most likely attributed to placental dysfunction. Multiple-marker screening can be used not only for the detection of fetal anomalies and aneu-ploidy but also for detection of high-risk pregnancies.

  1. Human West Nile virus infection in Bosnia and Herzegovina.

    PubMed

    Ahmetagić, Sead; Petković, Jovan; Hukić, Mirsada; Smriko-Nuhanović, Arnela; Piljić, Dilista

    2015-02-01

    To describe the first two cases of West Nile virus (WNV) neuroinvasive infections in Bosnia and Herzegovina. At the Clinic for Infectious Diseases of the University Clinical Centre Tuzla, Bosnia and Herzegovina (BiH), specific screening for WNV infection was performed on patients with neuroinvasive diseases from 1 August to 31 October 2013. Serum samples were tested for the presence of WNV IgM and IgG antibodies using enzyme-linked immunosorbent assay (ELISA); positive serum samples were further analyzed by detection of WNV nucleic acid of two distinct lineages (lineage 1 and lineage 2) in sera by RT-PCR. Three (out of nine) patients met clinical criteria, and two of them had high serum titre of WNV specific IgM antibodies (3.5 and 5.2). Serum RT-PCR testing was negative. Conformation by neutralization testing was not performed. Both cases represented with encephalitis. None of these cases had recent travel history in WNW endemic areas, or history of blood transfusion and organ transplantation, so they represented autochthonous cases. Although there were no previous reports of flavivirus infections in BiH, described cases had high titre of WNV specific antibodies in serum, and negative flavivirus-vaccination history, they were defined as probable cases because recommended testing for case confirmation was not performed. The West Nile virus should be considered a possible causative pathogen in this area, probably in patients with mild influenza-like disease of unknown origin and those with neuroinvasive disease during late summer and early autumn.

  2. An outcomes analysis of five prenatal screening strategies for trisomy 21 in women younger than 35 years.

    PubMed

    Biggio, Joseph R; Morris, T Christopher; Owen, John; Stringer, Jeffery S A

    2004-03-01

    This study was undertaken to examine the cost-effectiveness and procedural-related losses associated with 5 prenatal screening strategies for fetal aneuploidy in women under 35 years old. Five prenatal screening strategies were compared in a decision analysis model: triple screen: maternal age and midtrimester serum alpha-fetoprotein, human chorionic gonadotropin (hCG), and unconjugated estriol; quad screen: triple screen plus serum dimeric inhibin A; first-trimester screen: maternal age, serum pregnancy-associated plasma protein A and free beta-hCG and fetal nuchal translucency at 10 to 14 weeks' gestation; integrated screen: first-trimester screen plus quad screen, but first-trimester results are withheld until the quad screen is completed when a composite result is provided; sequential screen: first-trimester screen plus quad screen, but the first-trimester screen results are provided immediately and prenatal diagnosis offered if positive; later prenatal diagnosis is available if the quad screen is positive. Model estimates were literature derived, and cost estimates also included local sources. The 5 strategies were compared for cost, the numbers of Down syndrome fetuses detected and live births averted, and the number of procedure-related euploid losses. Sensitivity analyses were performed for parameters with imprecise point estimates. In the baseline analysis, sequential screening was the least expensive strategy ($455 million). It detected the most Down syndrome fetuses (n=1213), averted the most Down syndrome live births (n=678), but led to the highest number of procedure-related euploid losses (n=859). The integrated screen had the fewest euploid losses (n=62) and averted the second most Down syndrome live births (n=520). If fewer than 70% of women diagnosed with fetal Down syndrome elect to abort, the quad screen became the least expensive strategy. Although sequential screening was the most cost-effective prenatal screening strategy for fetal trisomy 21, it had the highest procedure-related euploid loss rate. The patient's perspective on detection versus fetal safety may help define the optimal screening strategy.

  3. Sensing CA 15-3 in point-of-care by electropolymerizing O-phenylenediamine (oPDA) on Au-screen printed electrodes.

    PubMed

    Gomes, Rui S; Moreira, Felismina T C; Fernandes, Ruben; Sales, M Goreti F

    2018-01-01

    This work presents an alternative device for cancer screening in liquid biopsies. It combines a biomimetic film (i) with electrochemical detection (ii). The biomimetic film (i) was obtained by electro-polymerizing amine-substituted benzene rings around a CA 15-3 target. This protein target was previously adsorbed on a gold (Au) support and incubated in charged monomers (4-Styrenesulfonate sodium and 3-Hydroxytyraminium chloride). The protein was further eliminated by enzymatic activity, leaving behind vacant sites for subsequent rebinding. Electrochemical detection (ii) was achieved on an Au working electrode, designed on commercial screen-printed electrodes. Raman spectroscopy, atomic force microscopy and ellipsometric readings were used to follow the chemical modification of the Au surface. The ability of the material to rebind CA15-3 was monitored by electrochemical techniques. The device displayed linear responses to CA15-3 ranging from 0.25 to 10.00 U/mL, with detection limits of 0.05 U/mL. Accurate results were obtained by applying the sensor to the analysis of CA15-3 in PBS buffer and in serum samples. This biosensing device displayed successful features for the detection of CA 15-3 and constitutes a promising tool for breast cancer screening procedures in point-of-care applications. Moreover, its scale-up seems feasible as it contains a plastic antibody assembled in situ, in less than 1 minute, and the analysis of serum takes less than 30 minutes.

  4. Prospective evaluation of 64 serum autoantibodies as biomarkers for early detection of colorectal cancer in a true screening setting

    PubMed Central

    Chen, Hongda; Werner, Simone; Butt, Julia; Zörnig, Inka; Knebel, Phillip; Michel, Angelika; Eichmüller, Stefan B.; Jäger, Dirk; Waterboer, Tim; Pawlita, Michael; Brenner, Hermann

    2016-01-01

    Novel blood-based screening tests are strongly desirable for early detection of colorectal cancer (CRC). We aimed to identify and evaluate autoantibodies against tumor-associated antigens as biomarkers for early detection of CRC. 380 clinically identified CRC patients and samples of participants with selected findings from a cohort of screening colonoscopy participants in 2005–2013 (N=6826) were included in this analysis. Sixty-four serum autoantibody markers were measured by multiplex bead-based serological assays. A two-step approach with selection of biomarkers in a training set, and validation of findings in a validation set, the latter exclusively including participants from the screening setting, was applied. Anti-MAGEA4 exhibited the highest sensitivity for detecting early stage CRC and advanced adenoma. Multi-marker combinations substantially increased sensitivity at the price of a moderate loss of specificity. Anti-TP53, anti-IMPDH2, anti-MDM2 and anti-MAGEA4 were consistently included in the best-performing 4-, 5-, and 6-marker combinations. This four-marker panel yielded a sensitivity of 26% (95% CI, 13–45%) for early stage CRC at a specificity of 90% (95% CI, 83–94%) in the validation set. Notably, it also detected 20% (95% CI, 13–29%) of advanced adenomas. Taken together, the identified biomarkers could contribute to the development of a useful multi-marker blood-based test for CRC early detection. PMID:26909861

  5. Sensing CA 15-3 in point-of-care by electropolymerizing O-phenylenediamine (oPDA) on Au-screen printed electrodes

    PubMed Central

    Gomes, Rui S.; Moreira, Felismina T. C.; Fernandes, Ruben

    2018-01-01

    This work presents an alternative device for cancer screening in liquid biopsies. It combines a biomimetic film (i) with electrochemical detection (ii). The biomimetic film (i) was obtained by electro-polymerizing amine-substituted benzene rings around a CA 15–3 target. This protein target was previously adsorbed on a gold (Au) support and incubated in charged monomers (4-Styrenesulfonate sodium and 3-Hydroxytyraminium chloride). The protein was further eliminated by enzymatic activity, leaving behind vacant sites for subsequent rebinding. Electrochemical detection (ii) was achieved on an Au working electrode, designed on commercial screen-printed electrodes. Raman spectroscopy, atomic force microscopy and ellipsometric readings were used to follow the chemical modification of the Au surface. The ability of the material to rebind CA15-3 was monitored by electrochemical techniques. The device displayed linear responses to CA15-3 ranging from 0.25 to 10.00 U/mL, with detection limits of 0.05 U/mL. Accurate results were obtained by applying the sensor to the analysis of CA15-3 in PBS buffer and in serum samples. This biosensing device displayed successful features for the detection of CA 15–3 and constitutes a promising tool for breast cancer screening procedures in point-of-care applications. Moreover, its scale-up seems feasible as it contains a plastic antibody assembled in situ, in less than 1 minute, and the analysis of serum takes less than 30 minutes. PMID:29715330

  6. An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.

    PubMed

    Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu

    2015-10-07

    This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.

  7. Risk of abnormal triple screen for Down syndrome is significantly higher in patients with female fetuses.

    PubMed

    Spong, C Y; Ghidini, A; Stanley-Christian, H; Meck, J M; Seydel, F D; Pezzullo, J C

    1999-04-01

    Previous studies have shown that mid-trimester maternal serum alpha-fetoprotein (AFP) levels are significantly higher and human chorionic gonadotrophin (hCG) levels significantly lower in women with male compared with female fetuses. We have evaluated whether triple-screen criteria are more likely to identify women with female fetuses as at risk for Down syndrome. From the Georgetown University genetics database we obtained the absolute values and corresponding multiples of the median (MoM) for AFP, hCG and unconjugated oestriol (uE3) in singleton gestations for the period database November 1992 July 1996. A Down syndrome risk of 1/270 or greater at mid-trimester was considered as high risk. A total of 977 patients with triple screen and outcome information were identified, including 502 female and 475 male fetuses. Patients with female fetuses were significantly more likely to have lower serum AFP (p=0.003) and a positive triple screen for Down syndrome (72 (14 per cent) versus 45 (9 per cent), p<0.02) than those with male fetuses. The gestational age at triple screen, maternal serum hCG and uE3, race and diabetes were not significantly different between the two groups. Since Down syndrome is less common in female than male fetuses, and the rates of female and male Down syndrome fetuses detected by triple screen and subsequent amniocentesis are not significantly different, the excess of positive mid-trimester maternal serum triple screen in women with female fetuses is likely due to false-positive results.

  8. Medication adherence in patients with apparent resistant hypertension: findings from the SYMPATHY trial.

    PubMed

    de Jager, Rosa L; van Maarseveen, Erik M; Bots, Michiel L; Blankestijn, Peter J

    2018-01-01

    Hypertension is only controlled in approximately 35% of the patients, which could be partially due to nonadherence. Recently, bioanalytical assessment of adherence to blood pressure (BP) lowering drugs has gaining interest. Our aim was to explore possible determinants of nonadherence in treatment resistant hypertension, assessed by objective screening for antihypertensive agents in serum. The secondary aim was to study the effect of adherence on the change in BP. This project was a substudy of SYMPATHY; an open-label randomized-controlled trial to assess the effect of renal denervation on BP 6 months after treatment compared to usual care in patients with resistant hypertension. Stored serum samples were screened for antihypertensive agents to assess adherence at baseline and 6 months after intervention, using liquid chromatography-tandem mass spectrometry. Office and 24-h BP were measured on the same day as blood was sampled. Patients and physicians were unaware of adherence measurements. Ninety-eight baseline and 83 6-month samples were available for analysis. Sixty-eight percent [95% confidence interval (CI) 59-78%] of the patients was nonadherent (n = 67). For every onw pill more prescribed, 0.785 [95%CI 0.529-0.891] prescribed pill was less detected in blood. A decrease of one pill in adherence between baseline and 6 months was associated with a significant rise in office systolic BP of 4 (95%CI 0.230-8.932) mmHg. Objective measurement of BP lowering drugs in serum, as a tool to assess adherence, showed that nonadherence was very common in patients with apparent resistant hypertension. Furthermore, the assessment results were related to (changes in) blood pressure. Our findings provide direct and objective methodology to help the physician to understand and to improve the condition of apparent resistant hypertension. © 2017 The British Pharmacological Society.

  9. A voltammetric method for Fe(iii) in blood serum using a screen-printed electrode modified with a Schiff base ionophore.

    PubMed

    Mittal, Susheel K; Rana, Sonia; Kaur, Navneet; Banks, Craig E

    2018-05-23

    Herein, a potent electrochemical ionophore (SMS-2) based on a Schiff base has been used for the modification of a screen-printed electrode (SPE). The modified disposable electrode can selectively detect ferric ions in an aqueous medium. Redox behavior of the proposed strip was characterized using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Incorporation of the ligand in the ink of the SPE enhanced the analytical performance of the electrode, and its surface modification was confirmed by SEM and EDX analysis. Shifting/quenching of the cathodic peak potential of the ionophore after binding with Fe(iii) ions was used to detect and measure the ferric ion concentration. This sensor can identify Fe(iii) in the detection range from 0.625 μM to 7.5 μM. The modified SPE can selectively detect ferric ions in the presence of many other interfering ions and has been successfully used to determine the Fe(iii) content in blood serum samples. The metal-ionophore complex structure was optimized using DFT calculations to study the energetics of the metal-ionophore interactions.

  10. Diagnostic reference range of κ/λ free light chain ratio to screen for Bence Jones proteinuria is not significantly influenced by GFR.

    PubMed

    Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke

    2016-05-01

    The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The NPC2 protein: A novel dog allergen.

    PubMed

    Khurana, Taruna; Newman-Lindsay, Shoshana; Young, Philip R; Slater, Jay E

    2016-05-01

    Dogs are an important source of indoor allergens that cause rhinoconjunctivitis, urticaria, and asthma in sensitized individuals. Can f 1 is reported as a major dog allergen, but other allergens have also been identified. Identification of immunologically important allergens is important for both the diagnosis and treatment of dog allergy. To identify and characterize the canine NPC2 protein, a novel dog allergen. We screened commercial and laboratory-generated aqueous dog extracts by 2-dimensional polyacrylamide gel electrophoresis with IgE immunoblotting using human serum samples from 71 dog-allergic individuals. A target of interest was excised from the gel and sequenced. Canine NPC2 sequence was generated, and recombinant proteins expressed in yeast and bacteria were used to determine allergenicity. An IgE enzyme-linked immunosorbent assay was used for screening 71 dog-positive and 30 dog-negative serum samples. A 16-kDa protein (pK = 8.5) in dog allergen extracts was recognized by specific IgE. The protein was identified by sequencing as a CE1 protein or NPC2 protein. Human IgE bound to recombinant protein was expressed in both yeast and bacteria. Ten (14%) of 71 individuals had specific IgE to NPC2 protein from bacteria, and 12 (17%) had IgE to NPC2 protein from yeast. Binding of pooled dog-allergic serum IgE to the dust mite protein Der p 2 was partially inhibited by recombinant NPC2 protein. NPC2 protein, a member of the MD-2-related lipid recognition family, is identified as a dog allergen (Can f 7), with an apparent seroprevalence of 10% to 20%. Published by Elsevier Inc.

  12. Broad screening and identification of β-agonists in feed and animal body fluid and tissues using ultra-high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry combined with spectra library search.

    PubMed

    Li, Tingting; Cao, Jingjing; Li, Zhen; Wang, Xian; He, Pingli

    2016-02-01

    Broad screening and identification of β-agonists in feed, serum, urine, muscle and liver samples was achieved in a quick and highly sensitive manner using ultra high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS) combined with a spectra library search. Solid-phase extraction technology was employed for sample purification and enrichment. After extraction and purification, the samples were analyzed using a Q-Orbitrap high-resolution mass spectrometer under full-scan and data-dependent MS/MS mode. The acquired mass spectra were compared with an in-house library (compound library and MS/MS mass spectral library) built with TraceFinder Software which contained the M/Z of the precursor ion, chemical formula, retention time, character fragment ions and the entire MS/MS spectra of 32 β-agonist standards. Screening was achieved by comparing 5 key mass spectral results and positive matches were marked. Using the developed method, the identification results from 10 spiked samples and 238 actual samples indicated that only 2% of acquired mass spectra produced false identities. The method validation results showed that the limit of detection ranged from 0.021-3.854 μg kg(-1)and 0.015-1.198 ng mL(-1) for solid and liquid samples, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Maternal serum alpha-fetoprotein levels are normal in Fanconi anemia: Can it be a lack of postnatal inhibition of AFP gene resulting in the elevation?

    PubMed

    Aslan, Deniz; Karabacak, Recep Onur; Aslan, Oner Deniz

    2017-04-01

    We investigated the feasibility of using serum alpha-fetoprotein (AFP) levels as a screening test for prenatal diagnosis of Fanconi anemia (FA). Serial measurements in maternal serum were recorded. Parents, both heterozygous for FA, had declined prenatal molecular testing. The infant was born with no somatic abnormalities, and FA was confirmed by postnatal molecular analysis. Maternal serum AFP levels during each trimester of pregnancy were normal indicating that these levels cannot be used as a screening test in prenatal diagnosis. Three-year follow-up after birth showed constantly elevated serum levels in the patient from the start, suggesting a lack of postnatal inhibition on AFP gene. © 2016 Wiley Periodicals, Inc.

  14. Rapid DNA extraction protocol for detection of alpha-1 antitrypsin deficiency from dried blood spots by real-time PCR.

    PubMed

    Struniawski, R; Szpechcinski, A; Poplawska, B; Skronski, M; Chorostowska-Wynimko, J

    2013-01-01

    The dried blood spot (DBS) specimens have been successfully employed for the large-scale diagnostics of α1-antitrypsin (AAT) deficiency as an easy to collect and transport alternative to plasma/serum. In the present study we propose a fast, efficient, and cost effective protocol of DNA extraction from dried blood spot (DBS) samples that provides sufficient quantity and quality of DNA and effectively eliminates any natural PCR inhibitors, allowing for successful AAT genotyping by real-time PCR and direct sequencing. DNA extracted from 84 DBS samples from chronic obstructive pulmonary disease patients was genotyped for AAT deficiency variants by real-time PCR. The results of DBS AAT genotyping were validated by serum IEF phenotyping and AAT concentration measurement. The proposed protocol allowed successful DNA extraction from all analyzed DBS samples. Both quantity and quality of DNA were sufficient for further real-time PCR and, if necessary, for genetic sequence analysis. A 100% concordance between AAT DBS genotypes and serum phenotypes in positive detection of two major deficiency S- and Z- alleles was achieved. Both assays, DBS AAT genotyping by real-time PCR and serum AAT phenotyping by IEF, positively identified PI*S and PI*Z allele in 8 out of the 84 (9.5%) and 16 out of 84 (19.0%) patients, respectively. In conclusion, the proposed protocol noticeably reduces the costs and the hand-on-time of DBS samples preparation providing genomic DNA of sufficient quantity and quality for further real-time PCR or genetic sequence analysis. Consequently, it is ideally suited for large-scale AAT deficiency screening programs and should be method of choice.

  15. Performance of a commercial serum ELISA for the detection of antibodies to Neospora caninum in whole and skim milk samples.

    PubMed

    Byrem, T M; Bartlett, P C; Donohue, H; Voisinet, B D; Houseman, J T

    2012-11-23

    Control of Neospora caninum infection in cattle depends on specific, ante-mortem detection of infected animals and limiting their use as breeding stock or by culling. The objective of the present study was to determine appropriate cut-off values and diagnostic performance of a milk ELISA test using whole and skim milk in a commercial serum ELISA test (IDEXX Neospora Ab). Serum and milk samples were obtained from a total of 475 lactating cows from two herds with and two herds without a previous history of N. caninum-associated abortion. Overall seroprevalence determined by the ELISA was 18.3%. Compared to serum ELISA values, correlation and overall performance assessed by receiver operating characteristic analysis was higher when either whole or skim milk samples were diluted 1:2 compared to undiluted or 1:5 diluted samples. Diagnostic performance for analysis of whole and skim milk was compared at cut-off values that achieved a desired operating characteristic of at least 95% specificity. For whole milk diluted 1:2 and a cut-off of 0.14 (S/P ratio), sensitivity and kappa values were 74.7% (95% CI 64.3-83.4) and 0.70 (95% CI 0.61-0.78), respectively. For skim milk diluted 1:2 and a cut-off of 0.30, sensitivity and kappa values were 77.0% (95% CI 66.8-85.4) and 0.72 (95% CI 0.64-0.80), respectively. Using the selected cut-offs, the IDEXX Neospora Ab Test is equally suited for the analysis of whole and skim milk as a screening tool in neosporosis control programs. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. The Prevalence of Brucellosis in Cattle, Goats and Humans in Rural Uganda: A Comparative Study.

    PubMed

    Miller, R; Nakavuma, J L; Ssajjakambwe, P; Vudriko, P; Musisi, N; Kaneene, J B

    2016-12-01

    A cross-sectional study was conducted to determine the presence of brucellosis in cattle, goats and humans in farms from south-western Uganda and identify risk factors associated with brucellosis in these three host groups. Data and serum samples were collected from 768 cattle, 315 goats and 236 humans, with 635 samples of bovine milk, from 70 farms in two different study areas in south-western Uganda. Sera from livestock were tested with the Rose Bengal Plate test, using B. abortus and B. melitensis antigens, and human sera were tested with a commercial IgG/IgM lateral flow assay. Milk samples were tested using the OIE-approved milk ring test. Screening tests for brucellosis were positive in 14% of cattle serum, 29% of bovine milk, 17% of goat serum and 11% of human serum samples. There were significant differences in the test prevalence of brucellosis by study site, with levels higher in the study area near Lake Mburo National Park than in the study area near Queen Elizabeth National Park. Multivariable regression models identified risk factors associated with increasing test positivity at the individual and farm levels for cattle, goats and humans. Positive associations were seen between increasing seropositivity of brucellosis in goats, cattle and humans. Results of multivariable analyses suggest that improvements in farm biosecurity and hygiene may reduce the risk of brucellosis on the farm and suggest a role for ticks in bovine brucellosis. Although cattle are the focus of brucellosis control in Uganda, the significant associations between seropositivity in humans and seropositivity in goats suggest that brucellosis in goats may be an important contributor to the epidemiology of the disease on the farm. © 2015 Blackwell Verlag GmbH.

  17. Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.

    PubMed

    Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J

    2016-10-01

    Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.

  18. Plasma endotoxin core antibody concentration and linear growth are unrelated in rural Malawian children aged 2-5 years.

    PubMed

    Benzoni, Nicole; Korpe, Poonum; Thakwalakwa, Chrissie; Maleta, Ken; Stephenson, Kevin; Manary, Micah; Manary, Mark

    2015-06-24

    Environmental enteropathy is subclinical inflammation of the upper gastrointestinal tract associated with reduced linear growth in developing countries. Usually investigators have used biopsy or a dual sugar absorption test to assess environmental enteropathy. Such tests are time and resource intensive, restricting their utility as screening methods. Serum endotoxin core antibody (EndoCab) concentration is a potential indicator of intestinal inflammation and integrity, and thus may be useful to predict environmental enteropathy. We analyzed the association of serum EndoCab levels versus linear growth and lactulose-mannitol assay results in 2-5 year old rural Malawian children. This was an observational study of 388 rural, asymptomatic Malawian children who had anthropometric measurements taken at least every 3 months since birth. In June and July 2011, dual sugar permeability tests were performed and serum samples were drawn for EndoCab assays. Pearson correlation, Student's t test and multivariable linear regression were used to compare ln EndoCab concentrations with height-for-age z scores (HAZ) at time of sampling and 3 months later. Identical analysis was also performed for ln EndoCab versus measurements from dual sugar permeability testing performed in conjunction with serum sampling. In a subgroup of children with anthropometric data in the months prior to serum sampling, Pearson correlation was used to estimate the relationship between ln EndoCab and recent linear growth. Ln EndoCab concentrations were not correlated with HAZ at time of measurement (B = -0.078, P = 0.14) nor change in HAZ over the subsequent 3 months HAZ (B = -0.018, P = 0.27). EndoCab concentration was not associated with %lactulose excretion (B < 0.001, P = 0.98) nor the lactulose:mannitol ratio (B = 0.021, P = 0.62). Subgroup analysis also did not reveal any significant association between EndoCab and recent growth. EndoCab titers were not correlated with measurements of growth or intestinal permeability in rural pre-school aged Malawian children.

  19. Serum bile acid concentrations in dairy cattle with hepatic lipidosis.

    PubMed

    Garry, F B; Fettman, M J; Curtis, C R; Smith, J A

    1994-01-01

    This study was designed to evaluate serum bile acid measurements as indicatory, of liver function and/or hepatic fat infiltration in dairy cattle. Serum bile acid concentrations were measured in healthy dairy cattle at different stages of lactation after fasting or feeding. Bile acid concentrations were compared with liver fat content and sulfobromophthalein (BSP) half-life (T 1/2). Serum bile acid concentrations were higher in cows in early lactation and with higher daily milk production. Compared with prefasting values, bile acid concentrations were decreased at 8, 14, and 24 hours of fasting. Blood samples from fed cows at 1- to 2-hour intervals had wide and inconsistent variations in bile acid concentration. Because serum bile acids correlated well with BSP T 1/2, it is suggested that both measurements evaluate a similar aspect of liver function. Neither bile acids nor BSP T 1/2 correlated with differences in liver fat content among cows. Because of large variability in serum bile acid concentrations in fed cows and the lack of correlation of measured values with liver fat content, bile acid determinations do not appear useful for showing changes in hepatic function in fed cows with subclinical hepatic lipidosis nor serve as a screening test for this condition.

  20. Maternal serum soluble fms-like tyrosine kinase-1 at 12, 22, 32 and 36 weeks' gestation in screening for pre-eclampsia.

    PubMed

    Tsiakkas, A; Mendez, O; Wright, A; Wright, D; Nicolaides, K H

    2016-04-01

    To examine the distribution of maternal serum soluble fms-like tyrosine kinase-1 (sFlt-1) at 12, 22, 32 and 36 weeks' gestation in singleton pregnancies that develop pre-eclampsia (PE) and examine the performance of this biomarker in screening for PE. Serum sFlt-1 was measured in 7066 cases at 11-13 weeks, 8079 cases at 19-24 weeks, 8472 at 30-34 weeks and 4043 at 35-37 weeks. Bayes' theorem was used to combine the a-priori risk from maternal characteristics and medical history with serum levels of sFlt-1. The performance of screening for PE in women requiring delivery < 32, between 32 + 0 and 36 + 6 and ≥ 37 weeks' gestation was estimated. In pregnancies that developed PE, serum sFlt-1 was increased and the separation in multiples of the median (MoM) values from normal was greater with earlier, compared to later, gestational age at which delivery for PE became necessary. In pregnancies that developed PE, the slope of the regression lines of sFlt-1 MoM with gestational age at delivery increased with advancing gestational age at screening. Measurement of sFlt-1 at 11-13 weeks did not improve the prediction of PE achieved by maternal factors alone, sFlt-1 at 19-24 weeks improved the prediction of PE delivering < 37 weeks but not for PE delivering ≥ 37 weeks, sFlt-1 at 30-34 weeks improved the prediction of PE delivering < 37 and PE delivering ≥ 37 weeks and sFlt-1 at 35-37 weeks improved the prediction of PE delivering ≥ 37 weeks. The detection rates (DRs), at a false-positive rate (FPR) of 10%, of PE delivering < 32 weeks were 52% and 65% with screening at 12 and 22 weeks, respectively. The DRs for PE delivering between 32 + 0 and 36 + 6 weeks were 44%, 44% and 93% with screening at 12, 22 and 32 weeks. The DR for PE delivering ≥ 37 weeks were 37%, 37%, 52% and 69% with screening at 12, 22, 32 and 36 weeks, respectively. The performance of combined screening with maternal factors, medical history and serum sFlt-1 is superior for detection of early, compared to late, PE and improves with advancing gestational age at screening. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  1. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    PubMed Central

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-01

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 μM for methanol and 0.2 μM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement. PMID:24412899

  2. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    PubMed

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  3. Autism Spectrum Disorder Risk in Relation to Maternal Mid-Pregnancy Serum Hormone and Protein Markers from Prenatal Screening in California

    ERIC Educational Resources Information Center

    Windham, Gayle C.; Lyall, Kristen; Anderson, Meredith; Kharrazi, Martin

    2016-01-01

    We examined prenatal screening markers and offspring autism spectrum disorder (ASD) using California statewide data on singleton births in 1996 and 2002. Second trimester levels of unconjugated estriol (uE3), human chorionic gonadotropin (hCG), and maternal serum alpha-fetoprotein (MSAFP) were compared between mothers of children with ASD…

  4. Diagnosis of gastritis caused by Helicobacter pylori in children by means of an ELISA.

    PubMed

    Czinn, S J; Carr, H S; Speck, W T

    1991-01-01

    In this study, the systemic immune response to bacterial cell sonicates of Helicobacter pylori was characterized in children with symptomatic gastroduodenal disease. Isotype-specific antibodies to H. pylori in samples of serum from 16 children with culture-proven disease caused by H. pylori and from 19 controls with negative cultures were measured by ELISA with bacterial cell lysates. The levels in serum of IgA antibody to cell sonicates of H. pylori were significantly higher in the patients with positive cultures than in the controls. Only 45% of patients were infected when the established optical density cutoff was used to discriminate between patients infected and not infected with H. pylori. Levels of IgM antibody in serum were not significantly higher in patients who were infected with H. pylori. On the basis of this survey and of previous work conducted in our laboratory, we conclude that at a serum dilution of 1:800, IgG but not IgA or IgM antibody to H. pylori is useful in the rapid screening of symptomatic children for the presence of H. pylori.

  5. Rapid Immunochromatographic Detection of Serum Anti-α-Galactosidase A Antibodies in Fabry Patients after Enzyme Replacement Therapy.

    PubMed

    Nakano, Sachie; Tsukimura, Takahiro; Togawa, Tadayasu; Ohashi, Toya; Kobayashi, Masahisa; Takayama, Katsuyoshi; Kobayashi, Yukuharu; Abiko, Hiroshi; Satou, Masatsugu; Nakahata, Tohru; Warnock, David G; Sakuraba, Hitoshi; Shibasaki, Futoshi

    2015-01-01

    We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy.

  6. Diagnostic performance of the EMIT-tox benzodiazepine immunoassay, FPIA serum benzodiazepine immunoassay, and radioreceptor assay in suspected acute poisoning.

    PubMed

    Verstraete, A G; Belpaire, F M; Leroux-Roels, G G

    1998-01-01

    We evaluated the diagnostic performance of the EMIT-tox serum benzodiazepine assay adapted to a Hitachi 717 analyzer (EMIT), the Abbott ADx serum benzodiazepine fluorescence polarization immunoassay (FPIA), and a radioreceptor assay (RRA) in 113 patients with suspected acute poisoning. The reference method was high-performance liquid chromatography with ultraviolet detection after solid-phase extraction. For the discrimination between negative and positive samples, the areas under the receiver-operating characteristic (ROC) curves were 0.976, 0.991, and 0.991 for EMIT (cutoff, 50-ng/mL diazepam), FPIA (cutoff, 12-ng/mL nordiazepam), and RRA (cutoff, 50-ng/mL diazepam), respectively. For the discrimination between non-toxic and toxic concentrations, the areas under the ROC curves were 0.896, 0.893, and 0.933, respectively. EMIT (with the cutoff lowered to 50 ng/mL), FPIA, and RRA can be reliably used to screen for the presence of benzodiazepines in serum, but in many cases they cannot discriminate between toxic and nontoxic concentrations.

  7. Comparison of the Abbott Architect i2000 assay, the Roche Modular Analytics E170 assay, and an immunoradiometric assay for serum hepatitis B virus markers.

    PubMed

    Kim, Hyunjung; Oh, Eun-Jee; Kang, Mi-Sook; Kim, Sung Hoon; Park, Yeon-Joon

    2007-01-01

    Serum hepatitis B virus (HBV) markers are the most important data for epidemiological screening and clinical diagnosis of HBV infection, especially in endemic areas. We compared the results of the Roche Modular Analytics E170 assay, the Abbott Architect i2000 assay, and an immunoradiometric assay (IRMA) for HBV surface antigen (HBsAg), anti-HBV surface antigen (anti-HBs), HBV e antigen (HBeAg), and anti-HBV e antigen (anti-HBe). A number of serum samples (264, 263, 224, and 202 for HBsAg, anti-HBs, HBeAg, and anti-HBe, respectively) were studied. For samples giving discrepant results for HBeAg between methods, real-time PCR assays were performed. The concordance rates among the three methods were high for HBsAg (100%) and HBeAg (94.6), but low for anti-HBs (91.6%) and anti-HBe (82.2%). For anti-HBs, which could be measured quantitatively by the Modular E170 and Architect i2000 procedures, discrepant results were observed at low levels of anti-HBs. For anti-HBe, the positive rate was highest with Modular E170 (60.9%) followed by the IRMA kit (54.1%) and Architect i2000 (51.0%). This study shows substantial differences between the assay results by the three methods, which should be taken into account in determinations of serum HBV markers.

  8. Evaluation of serum sialic acid, fucose levels and their ratio in oral squamous cell carcinoma.

    PubMed

    Chinnannavar, Sangamesh Ningappa; Ashok, Lingappa; Vidya, Kodige Chandrashekhar; Setty, Sunil Mysore Kantharaja; Narasimha, Guru Eraiah; Garg, Ranjana

    2015-01-01

    Detection of cancer at the early stage is of utmost importance to decrease the morbidity and mortality of the disease. Apart from the conventional biopsy, minimally invasive methods like serum evaluation are used for screening large populations. Thus, this study aimed to estimate serum levels of sialic acid and fucose and their ratio in oral cancer patients and in healthy control group to evaluate their role in diagnosis. Serum samples were collected from 52 healthy controls (group I) and 52 squamous cell carcinoma patients (group II). Estimation of serum levels of sialic acid and fucose and their ratio was performed. This was correlated histopathologically with the grades of carcinoma. Statistical analysis was done by using analysis of variance (ANOVA) test and unpaired "t" test. Results showed that serum levels of sialic acid and fucose were significantly higher in oral cancer patients compared to normal healthy controls (P < 0.001). The sialic acid to fucose ratio was significantly lower in cancer patients than in normal controls (P < 0.01). However, comparison with histological grading, habits, gender, and age group did not show any significant result. The mean serum sialic acid and fucose levels showed an increasing trend from controls to malignant group and their corresponding ratio showed decreasing trend from controls to malignant group. The ratio of sialic acid to fucose can be a useful diagnostic aid for oral cancer patients.

  9. Elevated levels of serum nidogen-2 in esophageal squamous cell carcinoma.

    PubMed

    Chai, Annie Wai Yeeng; Cheung, Arthur Kwok Leung; Dai, Wei; Ko, Josephine Mun Yee; Lee, Nikki Pui Yue; Chan, Kin Tak; Law, Simon Ying-Kit; Lung, Maria Li

    2018-02-14

    Nidogen-2 (NID2), a secretory basement membrane protein, has been implicated as a potential biomarker in ovarian cancer and hepatocellular carcinoma. In this study, we aimed to investigate the utility of detecting serum NID2 levels for identification of esophageal squamous cell carcinoma (ESCC) patients and prediction of poor survival outcome. Using an in-house NID2 enzyme-linked immunosorbent assay (ELISA), serum samples from 101 ESCC patients and 50 healthy controls were screened for their NID2 levels. The serum NID2 levels in ESCC patients (median 24.4 μg/L) are significantly higher (p= 4.3e-09) than that of the healthy controls (median 15.85 μg/L). The receiver operating characteristic (ROC) curve demonstrated an area under the curve of 0.756. At the threshold of 17.95 μg/L, the sensitivity and specificity achieved are 0.76 and 0.63, respectively. Kaplan-Meier survival analysis revealed that patients with high serum NID2 levels (⩾ 32.6 μg/L) have significantly higher risk of death (HR = 1.984, 95% CI: 1.175-3.349; log-rank p-value = 0.012) compared to those with low serum NID2 levels (< 20.0 μg/L). In conclusion, we show that detecting the elevation of serum NID2 levels has potential diagnostic and prognostic value for ESCC patients.

  10. Sensitivity and specificity of a nested polymerase chain reaction for detection of lentivirus infection in lions (Panthera leo).

    PubMed

    Adams, Hayley; van Vuuren, Moritz; Kania, Stephen; Bosman, Anna-Mari; Keet, Dewald; New, John; Kennedy, Melissa

    2010-12-01

    Feline immunodeficiency virus (FIV) is a lentivirus in the Retroviridae family that causes lifelong infection in domestic cats. The lentivirus of African lions (Panthera leo), referred to as FIVple, is endemic in certain lion populations in eastern and southern Africa. Lentivirus infection leads to immunologic dysfunction and immunosuppressive disease in domestic cats; however, little is known about the pathogenic effects of infection in lions, nor about the epidemiologic impact on free-ranging and captive populations. Whole blood and serum samples were collected opportunistically from free-ranging lions in Kruger National Park, Republic of South Africa (RSA). Whole blood and serum samples were also collected from captive wild lions in the RSA. A nested polymerase chain reaction (PCR) assay for detection of FIV was performed on all whole blood samples. In addition, serum samples were tested for cross-reactive antibodies to domestic feline lentivirus antigens and puma lentivirus synthetic envelope peptide antigen. The PCR assay successfully amplified the lion lentivirus from African lions. The relative sensitivity and relative specificity were 79% and 100%, respectively, and the positive and negative predictive values were 100% and 67%, respectively. This research represents the first study to compare genetic material with antibody-based methods of lentivirus detection on lions in RSA. Using PCR as an additional diagnostic test for FIV in lions will increase screening sensitivity and will allow viral characterization among circulating isolates and monitoring of changes in the viral epidemiology within geographic regions and populations over time.

  11. Seroprevalence of parvovirus B19 antibodies and evidence of viremia among Nigerian patients with sickle cell anemia

    PubMed Central

    Iwalokun, Bamidele Abiodun; Iwalokun, Senapon Olusola; Hodonu, Semande Olufunmilayo

    2013-01-01

    Clinical, biochemical and molecular evidence for the sickle cell anemia (SCA) crisis in Nigerian patients arising from parvovirus b19 infection remains inadequate. This study determined the prevalence and correlates of anti-parvovirus b19 antibodies in a population of SCA patients and non-SCA healthy controls in Lagos, Nigeria. In this prospective cross-sectional study, we enrolled 73 confirmed SCA patients from 5 district hospitals in Lagos and 81 sex and age-matched non-SCA healthy controls. Serum sample from each study participant was screened for anti-parvovirus b19 by ELISA and PCR techniques. Standard biomedical assays were also done. Anti-parvovirus b19 IgM and IgG antibodies were detected in 22 (14.3%) and 97 (62.9%) of the 154 sera screened, 13 (17.8%) and 45 (61.6%) in SCA patients; 9 (11.1%) and 52 (64.2%) in non-SCA controls. The overall seronegativity rate was 19.5%. Parvovirus B19 DNA was found in 2 (11.1%) of the 18 IgM seropositive SCA serum samples screened. On the whole, parvovirus b19 infection was more commonly asymptomatic in non-SCA controls but caused significant elevation in liver enzymes in infected SCA patients (P < 0.05). The risk of acute parvovirus b19 infection increased 65 times during unsteady state among the SCA patients. Although no deaths of infected patients were recorded during the study, age below 12 years, hospitalization and overcrowded environment were risk factors for infection. We conclude that parvovirus b19 is common in SCA patients, incurring greater susceptibility to infections. PMID:23885266

  12. Evaluation of a 5-Marker Blood Test for Colorectal Cancer Early Detection in a Colorectal Cancer Screening Setting.

    PubMed

    Werner, Simone; Krause, Friedemann; Rolny, Vinzent; Strobl, Matthias; Morgenstern, David; Datz, Christian; Chen, Hongda; Brenner, Hermann

    2016-04-01

    In initial studies that included colorectal cancer patients undergoing diagnostic colonoscopy, we had identified a serum marker combination able to detect colorectal cancer with similar diagnostic performance as fecal immunochemical test (FIT). In this study, we aimed to validate the results in participants of a large colorectal cancer screening study conducted in the average-risk, asymptomatic screening population. We tested serum samples from 1,200 controls, 420 advanced adenoma patients, 4 carcinoma in situ patients, and 36 colorectal cancer patients with a 5-marker blood test [carcinoembryonic antigen (CEA)+anti-p53+osteopontin+seprase+ferritin]. The diagnostic performance of individual markers and marker combinations was assessed and compared with stool test results. AUCs for the detection of colorectal cancer and advanced adenomas with the 5-marker blood test were 0.78 [95% confidence interval (CI), 0.68-0.87] and 0.56 (95% CI, 0.53-0.59), respectively, which now is comparable with guaiac-based fecal occult blood test (gFOBT) but inferior to FIT. With cutoffs yielding specificities of 80%, 90%, and 95%, the sensitivities for the detection of colorectal cancer were 64%, 50%, and 42%, and early-stage cancers were detected as well as late-stage cancers. For osteopontin, seprase, and ferritin, the diagnostic performance in the screening setting was reduced compared with previous studies in diagnostic settings while CEA and anti-p53 showed similar diagnostic performance in both settings. Performance of the 5-marker blood test under screening conditions is inferior to FIT even though it is still comparable with the performance of gFOBT. CEA and anti-p53 could contribute to the development of a multiple marker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.

  13. A strategical re-thinking on National Blood Donor Pool: Anti-HBc positivity related re-entry mechanisms.

    PubMed

    Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat

    2016-04-01

    Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.

  14. Promoter methylation of MCAM, ERα and ERβ in serum of early stage prostate cancer patients.

    PubMed

    Brait, Mariana; Banerjee, Mithu; Maldonado, Leonel; Ooki, Akira; Loyo, Myriam; Guida, Elisa; Izumchenko, Evgeny; Mangold, Leslie; Humphreys, Elizabeth; Rosenbaum, Eli; Partin, Alan; Sidransky, David; Hoque, Mohammad Obaidul

    2017-02-28

    Prostate cancer (PC) is the second most common cancer among men worldwide. Currently, the most common non-invasive approach for screening and risk assessment of PC is measuring the level of serum prostate-specific antigen (PSA). However, the sensitivity of PSA is 42.8 % and specificity is 41.1%. As a result, the serum PSA test leads to numerous unneeded biopsies. Therefore, a rigorous search for biomarkers for early detection of PC is ongoing. In this study, we aim to assess a panel of epigenetic markers in an intend to develop an early detection test for PC. The sensitivity and specificity of hypermethylation of MCAM was 66% and 73% respectively which is an improvement from the sensitivity and specificity of PSA. Considering a combination marker panel of MCAM, ERα and ERβ increased the sensitivity to 75% and the specificity became 70% for the minimally invasive early detection test of PC. Sixteen primary matched tumor and serum were analyzed by quantitative methylation specific PCR (QMSP) to determine analytical and clinical sensitivity of the genes tested (SSBP2, MCAM, ERα, ERβ, APC, CCND2, MGMT, GSTP1, p16 and RARβ2). Additionally, serum samples from eighty four cases of PC, thirty controls and seven cases diagnosed as high grade Prostatic Intraepithelial Neoplasia (HGPIN) were analyzed. Promoter methylation of MCAM, ERα and ERβ have a potential to be utilized as biomarker for the early detection of prostate PC as their sensitivity and specificity seem to be better than serum PSA in our cohort of samples. After robust validation in a larger prospective cohort, our findings may reduce the numbers of unwarranted prostate biopsies.

  15. A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.

    PubMed

    Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E

    2014-08-27

    Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Use of a recombinant burkholderia intracellular motility a protein for immunodiagnosis of glanders.

    PubMed

    Kumar, Subodh; Malik, Praveen; Verma, Shailendra Kumar; Pal, Vijai; Gautam, Vandana; Mukhopadhyay, Chiranjay; Rai, Ganga Prasad

    2011-09-01

    Glanders, caused by the Gram-negative, nonmotile bacterium Burkholderia mallei, is a contagious and highly fatal disease of equines. During the last decade, the number of glanders outbreaks has increased steadily. The disease also has high zoonotic significance and B. mallei is listed biological warfare agent. The complement fixation test (CFT) is a routinely used and internationally recognized test to screen equine sera for the glanders. However, discrepant results have been observed using the CFT. The low sensitivity and specificity of the CFT and enzyme-linked immunosorbent assay (ELISA) have been linked to the use of crude test antigens. We expressed a novel recombinant Burkholderia intracellular motility A (rBimA) protein in Escherichia coli for the diagnosis of equine glanders. Purified rBimA was used in an indirect ELISA format. All of the 21 true-positive serum samples used in the study tested positive, whereas only 17 of the 1,524 potentially negative sera tested positive by indirect ELISA, thus exhibiting 100% sensitivity and 98.88% specificity. Also, rBimA protein did not react with melioidosis patient and normal healthy human serum samples, showing its high specificity. The developed assay can be used as a simple and rapid tool for diagnosis of glanders in equine serum samples. An Indian patent (1328/DEL/2010) has been filed for the reagent.

  17. Detection of reticuloendotheliosis virus as a contaminant of fowl pox vaccines.

    PubMed

    Awad, A M; Abd El-Hamid, H S; Abou Rawash, A A; Ibrahim, H H

    2010-11-01

    This study was designed to detect reticuloendotheliosis virus (REV) as a contaminant in fowl pox vaccines. A total of 30 fowl pox vaccine samples were examined for the presence of REV using both in vitro and in vivo methods. In in vitro testing, the fowl pox vaccine samples were inoculated into chicken embryo fibroblast cultures prepared from specific-pathogen-free embryonated chicken eggs, and the cultures were examined using PCR to detect REV. In in vivo testing, each fowl pox vaccine sample was inoculated into 5-d-old specific-pathogen-free chicks, which were kept under observation for up to 12 wk postinoculation; serum samples were collected at 15, 30, and 45 d postinoculation for the detection of REV-specific antibodies using ELISA. Tissue samples were collected at 8 and 12 wk postinoculation for histopathological examination. Of the tested vaccines, only one imported vaccine sample tested positive for REV using PCR. Serum samples collected from chicks infected with the PCR-positive vaccine batch also tested positive for REV-specific antibodies using ELISA. Histopathological examination of the liver, spleen, and bursa of Fabricius demonstrated the presence of tumor cells in these organs, confirming the results obtained using PCR and ELISA, and indicating that the sample was contaminated with REV. These data clearly indicate that the screening of all commercial poultry vaccines for viruses is an important factor in assuring the biosafety of animal vaccines.

  18. Assessment of nucleosides as putative tumor biomarkers in prostate cancer screening by CE-UV.

    PubMed

    Buzatto, Adriana Zardini; de Oliveira Silva, Mariana; Poppi, Ronei Jesus; Simionato, Ana Valéria Colnaghi

    2017-05-01

    Cancer is responsible for millions of deaths worldwide, but most base diseases may be cured if detected early. Screening tests may be used to identify early-stage malignant neoplasms. However, the major screening tool for prostate cancer, the prostate-specific antigen test, has unsuitable sensitivity. Since cancer cells may affect the pattern of consumption and excretion of nucleosides, such biomolecules are putative biomarkers that can be used for diagnosis and treatment evaluation. Using a previously validated method for the analysis of nucleosides in blood serum by capillary electrophoresis with UV-vis spectroscopy detection, we investigated 60 samples from healthy individuals and 42 samples from prostate cancer patients. The concentrations of nucleosides in both groups were compared and a multivariate partial least squares-discriminant analysis classification model was optimized for prediction of prostate cancer. The validation of the model with an independent sample set resulted in the correct classification of 82.4% of the samples, with sensitivity of 90.5% and specificity of 76.7%. A significant downregulation of 5-methyluridine and inosine was observed, which can be indicative of the carcinogenic process. Therefore, such analytes are potential candidates for prostate cancer screening. Graphical Abstract Separation of the studied nucleosides and the internal standard 8-Bromoguanosine by CE-UV (a); classification of the external validation samples (30 from healthy volunteers and 21 from prostate cancer patients) by the developed Partial Least Square - Discriminant Analysis (PLS-DA) model with accuracy of 82.4% (b); Receiver Operating Characteristics (ROC) curve (c); and Variable Importance in the Projection (VIP) values for the studied nucleosides (d). A significant down-regulation of 5- methyluridine (5mU) and inosine (I) was observed, which can be indicative of the presence of prostate tumors.

  19. Delayed Ejaculation and Associated Complaints: Relationship to Ejaculation Times and Serum Testosterone Levels.

    PubMed

    Morgentaler, Abraham; Polzer, Paula; Althof, Stanley; Bolyakov, Alexander; Donatucci, Craig; Ni, Xiao; Patel, Ankur B; Basaria, Shehzad

    2017-09-01

    Although delayed ejaculation (DE) is typically characterized as a persistently longer than anticipated or desired time to ejaculation (or orgasm) during sexual activity, a timing-based definition of DE and its association with serum testosterone has not been established in a large cohort. To examine in an observational study estimated intravaginal ejaculatory latency time (IELT) and masturbatory ejaculation latency time (MELT) in men self-reporting DE, assess the association of IELT and MELT with serum testosterone levels, and determine whether correlation with demographic and sexual parameters exist. Men who resided in the United States, Canada, and Mexico were enrolled from 2011 to 2013. Self-estimated IELT and MELT were captured using an Ejaculatory Function Screening Questionnaire in a sample of 988 men screened for possible inclusion in a randomized clinical trial assessing testosterone replacement therapy for ejaculatory dysfunction (EjD) and who self-reported the presence or absence of DE and symptoms of hypogonadism. Additional comorbid EjDs (ie, anejaculation, perceived decrease in ejaculate volume, and decreased force of ejaculation) were recorded. Men with premature ejaculation were excluded from this analysis. IELT and MELT were compared between men self-reporting DE and men without DE. The associations of IELT and MELT with serum testosterone were measured. IELT, MELT, and total testosterone levels. Sixty-two percent of screened men self-reported DE with or without comorbid EjDs; 38% did not report DE but did report at least one of the other EjDs. Estimated median IELTs were 20.0 minutes for DE vs 15 minutes for no DE (P < .001). Estimated median MELTs were 15.0 minutes for DE vs 8.0 minutes for no DE (P < .001). Ejaculation time was not associated with serum testosterone levels. Younger men and those with less severe erectile dysfunction had longer IELTs and MELTs. Estimated ejaculation times during vaginal intercourse and/or masturbation were not associated with serum testosterone levels in this study; thus, routine androgen evaluation is not indicated in these men. This large systematic analysis attempted to objectively assess the ejaculation latency in men with self-reported DE. Limitations were that ejaculation time estimates were self-reported and were queried only once; the questionnaire did not distinguish between failure to achieve orgasm and ejaculation; and assessment of DE was limited to heterosexual vaginal intercourse and masturbation. IELT and MELT were longer in men with DE, and there was no association of ejaculation times with serum testosterone levels in this study population. Morgentaler A, Polzer P, Althof S, et al. Delayed Ejaculation and Associated Complaints: Relationship to Ejaculation Times and Serum Testosterone Levels. J Sex Med 2017;14:1116-1124. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  20. Utility of metabolic profiling of serum in the diagnosis of pregnancy complications.

    PubMed

    Powell, Katie L; Carrozzi, Anthony; Stephens, Alexandre S; Tasevski, Vitomir; Morris, Jonathan M; Ashton, Anthony W; Dona, Anthony C

    2018-06-01

    Currently there are no clinical screening tests available to identify pregnancies at risk of developing preeclampsia (PET) and/or intrauterine growth restriction (IUGR), both of which are associated with abnormal placentation. Metabolic profiling is now a stable analytical platform used in many laboratories and has successfully been used to identify biomarkers associated with various pathological states. We used nuclear magnetic resonance spectroscopy (NMR) to metabolically profile serum samples collected from 143 pregnant women at 26-41 weeks gestation with pregnancy outcomes of PET, IUGR, PET IUGR or small for gestational age (SGA) that were age-matched to normal pre/term pregnancies. Spectral analysis found no difference in the measured metabolites from normal term, pre-term and SGA samples, and of 25 identified metabolites, only glutamate was marginally different between groups. Of the identified metabolites, 3-methylhistidine, creatinine, acetyl groups and acetate, were determined to be independent predictors of PET and produced area under the curves (AUC) = 0.938 and 0.936 for the discovery and validation sets. Only 3-hydroxybutyrate was determined to be an independent predictor of IUGR, however the model had low predictive power (AUC = 0.623 and 0.581 for the discovery and validation sets). A sub-panel of metabolites had strong predictive power for identifying PET samples in a validation dataset, however prediction of IUGR was more difficult using the identified metabolites. NMR based metabolomics can identify metabolites strongly associated with disease and has the potential to be useful in developing early clinical screening tests for at risk pregnancies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Seroprevalence of Toxoplasma gondii infection Among Β-Thalassemia Major Pediatric Population: Implications for Transfusion Transmissible Toxoplasmosis.

    PubMed

    El-Tantawy, Nora; Darwish, Ahmad; Eissa, Eman

    2018-05-14

    Children with β-thalassemia major who regularly receive blood transfusion are at risk of developing transfusion-transmitted infection. Toxoplasmosis is a common and a serious parasitic disease with high prevalence and could be transmitted through blood transfusion from healthy asymptomatic donors. However, screening Toxoplasma gondii before blood donation has not been considered. To determine the prevalence of T. gondii antibodies among thalassemia children undergoing blood transfusion. In a case-control study, serum samples from 211 thalassemia children and 100 control children were investigated for Toxoplasma IgM and IgG using the enzyme-linked immunosorbent assay (ELISA). Positive serum samples for IgG antibodies to T. gondii were further subjected to IgG avidity ELISA. The seroprevalence of Toxoplasma infection among thalassemia children was 23.2% and 53.6% for IgM and IgG anti-Toxoplasma antibodies, respectively. Whereas in the contro group, the prevalence was 5% and 18% for IgM and IgG anti-Toxoplasma antibodies, respectively. There is a significant statistical difference between thalassemia and control groups regarding the prevalence of toxoplasmosis. From these positive IgG samples, 65.5% have low avidity indicating recent infection while 38.73% have high avidity indicating past infection. Due to the high serologic infection rate of toxoplasmosis among thalassemia pediatric population in this study with no existing effective therapies and no available T. gondii vaccine, appropriate strategies are critical for reducing the risk of that infection. Screening of blood for T. gondii antibodies should be considered before transmission to those children especially in countries with a high prevalence of toxoplasmosis.

  2. First Trimester Maternal Serum Screening Using Biochemical Markers PAPP-A and Free β-hCG for Down Syndrome, Patau Syndrome and Edward Syndrome.

    PubMed

    Shiefa, S; Amargandhi, M; Bhupendra, J; Moulali, S; Kristine, T

    2013-01-01

    The first trimester screening programme offers a noninvasive option for the early detection of aneuploidy pregnancies. This screening is done by a combination of two biochemical markers i.e. serum free β-human chorionic gonadotrophin (free β-hCG) and pregnancy associated plasma protein A (PAPP-A), maternal age and fetal nuchal translucency (NT) thickness at 11 + 0-13 + 6 weeks of gestation. A beneficial consequence of screening is the early diagnosis or trisomies 21, 18 and 13. At 11 + 0-13 + 6 weeks, the relative prevalence of trisomies 18 and 13 to trisomy 21 are found to be one to three and one to seven, respectively. All three trisomies are associated with increased maternal age, increased fetal NT and decreased PAPP-A, but in trisomy 21 serum free β-hCG is increased whereas in trisomies 18 and 13 free β-hCG is decreased.

  3. A round robin approach to the analysis of bisphenol a (BPA) in human blood samples

    PubMed Central

    2014-01-01

    Background Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. Methods Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. Results We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. Conclusions Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. PMID:24690217

  4. Construction of helper plasmid-mediated dual-display phage for autoantibody screening in serum.

    PubMed

    Rajaram, Kaushik; Vermeeren, Veronique; Somers, Klaartje; Somers, Veerle; Michiels, Luc

    2014-01-01

    M13 filamentous bacteriophage has been used in displaying disease-specific antibodies, biomarkers, and peptides. One of the major drawbacks of using phage in diagnostic assays is the aspecific adsorption of proteins leading to a high background signal and decreasing sensitivity. To deal with this, we developed a genetically pure, exchangeable dual-display phage system in which biomarkers and streptavidin-binding protein (SBP) are displayed at opposite ends of the phage. This approach allows for sample purification, using streptavidin-coated magnetic beads resulting in a higher sensitivity of signal detection assays. Our dual-display cassette system approach also allows for easy exchange of both the anchor protein (SBP) and the displayed biomarker. The presented principle is applied for the detection of antibody reactivity against UH-RA.21 which is a good candidate biomarker for rheumatoid arthritis (RA). The applicability of dual-display phage preparation using a helper plasmid system is demonstrated, and its increased sensitivity in phage ELISA assays using patient serum samples is shown.

  5. [Preparation of freeze - drying control materials of IgG antibody against Schistosoma japonicum for immunodetection kits].

    PubMed

    Jin, Huang; Chun-Lian, Tang; Zu-Wu, Tu; Li, Tang; Ke-Hui, Zhang; Qian, Li; Jun, Ye

    2018-04-18

    To prepare freeze-drying control materials of IgG antibody against Schistosoma japonicum for detection kits. The serum samples of schistosomiasis patients from endemic areas and normal people without history of schistosome infection or contact with infested water in Hubei Province were collected. All the sera were detected by the method approved by China Food and Drug Administration and selected for preparation of quality control samples. Totally twelve positive quality control materials, ten negative quality control materials, and one sensitive and one precision quality control materials were screened. According to the positive serum level, the positive degrees of quality control materials were divided into strong, medium and weak levels. The stability could be valid for one year. The freeze-drying quality control materials of IgG antibody against S. japonicum for detection kits are prepared. They are easy to use and have good stability, and therefore, they may meet the requirement of quality control for the detection of schistosomiasis diagnostics kits.

  6. Evaluation of ID-PaGIA syphilis antibody test.

    PubMed

    Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi

    2009-01-01

    Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.

  7. Maternity care and maternal serum screening. Do male and female family physicians care for women differently?

    PubMed

    Woodward, C A; Carroll, J C; Ryan, G; Reid, A J; Permaul-Woods, J A; Arbitman, S; Domb, S B; Fallis, B; Kilthei, J

    1997-06-01

    To examine whether male and female family physicians practise maternity care differently, particularly regarding the maternal serum screening (MSS) program. Mailed survey fielded between October 1994 and March 1995. Ontario family practices. Random sample of 2000 members of the College of Family Physicians of Canada who care for pregnant women. More than 90% of eligible physicians responded. Attitudes toward, knowledge about, and behaviour toward MSS. Women physicians were more likely than men to practise part time, in groups, and in larger communities. Men physicians were more likely to perform deliveries; women were more likely to do shared care. Despite a shorter work week, on average, female physicians cared for more pregnant women than male physicians did. Among those providing intrapartum care, women performed more deliveries, on average, than men. Women physicians were more likely than men to offer MSS to all pregnant patients. Although average time spent discussing MSS before the test was similar, women physicians had better knowledge of when best to do the test and its true-positive rate. All differences reported were statistically significant (P < or = 0.001). Among family physicians caring for pregnant women, women physicians cared for more pregnant women than men did. Both spent similar time discussing MSS with their patients before offering screening, but more women physicians offered MSS to all their patients and were more knowledgeable about MSS than men physicians.

  8. Epitope presentation is an important determinant of the utility of antigens identified from protein arrays in the development of autoantibody diagnostic assays.

    PubMed

    Murphy, Mairead A; O'Connell, David J; O'Kane, Sara L; O'Brien, John K; O'Toole, Sharon; Martin, Cara; Sheils, Orla; O'Leary, John J; Cahill, Dolores J

    2012-08-03

    Autoantibodies represent an attractive biomarker for diagnostic assays principally due to the stability of immunoglobulin in patient serum facilitating measurement with conventional assays. Immune responses to tumorigenesis may facilitate detection of ovarian cancer in the early stages of the disease with identification of a panel of tumour specific autoantibodies. Despite the reporting of many tumour associated autoantibodies using arrays of tumour antigens, this has not led to the advance in diagnostic capability as rapidly as was initially expected. Here we examine the potential diagnostic utility of candidate autoantibody biomarkers identified via screening of serum samples on a high content human protein array from a unique cohort of early stage and late stage ovarian cancer patients. We analyse the performance of autoantibodies to the tumour suppressor protein p53 and the novel autoantigens alpha adducin and endosulfine alpha identified in our array screen. Each antigen has different performance characteristics using conventional ELISA format and Western blot immunoassay. The high attrition rate of promising autoantigens identified by array screening can in part be explained by the presentation of the epitope of the antigen in the subsequent method of validation and this study provides directions on maximising the potential of candidate biomarkers. This article is part of a Special Issue entitled: Translational Proteomics. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  10. Comprehensive identification of Vibrio vulnificus genes required for growth in human serum.

    PubMed

    Carda-Diéguez, M; Silva-Hernández, F X; Hubbard, T P; Chao, M C; Waldor, M K; Amaro, C

    2018-12-31

    Vibrio vulnificus can be a highly invasive pathogen capable of spreading from an infection site to the bloodstream, causing sepsis and death. To survive and proliferate in blood, the pathogen requires mechanisms to overcome the innate immune defenses and metabolic limitations of this host niche. We created a high-density transposon mutant library in YJ016, a strain representative of the most virulent V. vulnificus lineage (or phylogroup) and used transposon insertion sequencing (TIS) screens to identify loci that enable the pathogen to survive and proliferate in human serum. Initially, genes underrepresented for insertions were used to estimate the V. vulnificus essential gene set; comparisons of these genes with similar TIS-based classification of underrepresented genes in other vibrios enabled the compilation of a common Vibrio essential gene set. Analysis of the relative abundance of insertion mutants in the library after exposure to serum suggested that genes involved in capsule biogenesis are critical for YJ016 complement resistance. Notably, homologues of two genes required for YJ016 serum-resistance and capsule biogenesis were not previously linked to capsule biogenesis and are largely absent from other V. vulnificus strains. The relative abundance of mutants after exposure to heat inactivated serum was compared with the findings from the serum screen. These comparisons suggest that in both conditions the pathogen relies on its Na + transporting NADH-ubiquinone reductase (NQR) complex and type II secretion system to survive/proliferate within the metabolic constraints of serum. Collectively, our findings reveal the potency of comparative TIS screens to provide knowledge of how a pathogen overcomes the diverse limitations to growth imposed by serum.

  11. Development of an indirect enzyme-linked immunosorbent assay test for detecting antibodies to chicken astrovirus in chicken sera.

    PubMed

    Skibinska, A; Lee, A; Wylie, M; Smyth, V J; Welsh, M D; Todd, D

    2015-01-01

    The development of an indirect enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of Group B chicken astrovirus (CAstV) infections is described. The test was based on the use of an affinity-purified capsid antigen, specific to CAstV isolate 11672, produced as a glutathione-S-transferase N-terminal fusion protein by a recombinant baculovirus. Strongly positive ELISA signals were elicited against experimentally produced antisera raised to CAstVs from Group B (subgroups i and ii) but were negative for antisera raised to a Group A CAstV. Using a panel of 240 selected serum samples, 99% agreement was observed when the results obtained by ELISA were compared to those from an indirect immunofluorescence test for CAstV 11672. The ELISA test was applied to 68 serum sets comprising 1864 samples, which were obtained from parent and grandparent flocks originating mainly in the UK. Of the 52 sets containing ELISA-positive samples, 24 sets had >75% samples positive and nine sets had <25% samples positive and were regarded as having high and low seropositivities, respectively. Of the 1864 serum samples tested 1090 (58.5%) were ELISA positive and of these, 234 sera (21.5%) produced strongly positive signals, whereas moderately positive and weakly positive signals were produced by 562 (51.5%) and 294 (27%) sera. When used for flock screening purposes, this ELISA test can be used to (i) investigate the occurrence of first-time CAstV infections of parent flocks during lay and the possible adverse effects caused by vertically transmitted CAstV infections on broiler hatchability and performance and (ii) diagnose Group B CAstV infections within specific pathogen free flocks.

  12. Detection of human parvovirus B19 in serum samples from children under 5 years of age with rash-fever illnesses in the Democratic Republic of the Congo.

    PubMed

    Wawina, Tony Bokalanga; Tshiani, Olivier Mbaya; Ahuka, Steve Mundeke; Pukuta, Elisabeth Simbu; Aloni, Michel Ntetani; Kasanga, Christopher Jacob; Muyembe, Jean-Jacques Tamfum

    2017-12-01

    It has been demonstrated that infection with human parvovirus B19 (B19V) is associated with rash-fever illnesses. The present study aimed to investigate B19V as an aetiological agent of rash-fever syndromes in Congolese children confirmed as measles and rubella IgM-negative. An ELISA IgM test and PCR were performed to screen for B19V. A total of 177 archived serum samples were randomly selected from the measles biobank of the National Institute for Biomedical Research (INRB). Samples were investigated for anti-B19V IgM and B19V DNA. These samples originated from children <5years of age with measles-like rashes, previously confirmed as negative for both measles and rubella IgM. Out of 177 serum samples tested by ELISA and 168 tested by PCR, 109 were positive for B19V IgM antibodies (61.6%) and 87 (51.8%) were positive for B19V DNA. Positive samples in both assays were from all provinces of DRC. B19V plays a role in rash-fever illnesses in children under 5 years of age suspected of having measles or rubella infections in DRC. As an aetiological cause of rash and fever syndromes, the present study demonstrates that B19V should also be considered during the laboratory investigation of rash-fever illnesses in DRC, particularly in the paediatric population. There is a need to conduct further studies in order to gain a better understanding of the spatiotemporal pattern of B19V and to define the genotype(s) of B19V circulating in DRC. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. Bronchoalveolar lavage fluid of lung cancer patients: mapping the uncharted waters using proteomics technology.

    PubMed

    Oumeraci, Tonio; Schmidt, Bernd; Wolf, Thomas; Zapatka, Marc; Pich, Andreas; Brors, Benedikt; Eils, Roland; Fleischhacker, Michael; Schlegelberger, Brigitte; von Neuhoff, Nils

    2011-04-01

    The search for proteome-level markers of non-small cell lung cancer (NSCLC) has been mainly limited to serum or cell line screening approaches up to this point. We would like to demonstrate by this proof-of-principle study investigating bronchoalveolar lavage fluid samples from a cohort of NSCLC and control patients, that this readily available biofluid might be a more suitable source for discovering clinically usable NSCLC biomarkers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Cognitive impairment in heart failure: issues of measurement and etiology.

    PubMed

    Riegel, Barbara; Bennett, Jill A; Davis, Andra; Carlson, Beverly; Montague, John; Robin, Howard; Glaser, Dale

    2002-11-01

    Clinicians need easy methods of screening for cognitive impairment in patients with heart failure. If correlates of cognitive impairment could be identified, more patients with early cognitive impairment could be treated before the problem interfered with adherence to treatment. To describe cognitive impairment in patients with heart failure, to explore the usefulness of 4 measures of cognitive impairment, and to assess correlates of cognitive impairment. A descriptive, correlational design was used. Four screening measures of cognition were assessed in 42 patients with heart failure: Commands subtest and Complex Ideational Material subtest of the Boston Diagnostic Aphasia Examination, Mini-Mental State Examination, and Draw-a-Clock Test. Cognitive impairment was defined as performance less than the standardized (T-score) cutoff point on at least 1 of the 4 measures. Possible correlates of cognitive impairment included age, education, hypotension, fluid overload (serum osmolality < 269 mOsm/kg), and dehydration (serum osmolality > or = 295 mOsm/kg). Cognitive impairment was detected in 12 (28.6%) of 42 participants. The 4 screening tests varied in effectiveness, but the Draw-a-Clock Test indicated impairment in 50% of the 12 impaired patients. A summed standardized score for the 4 measures was not significantly associated with age, education, hypotension, fluid overload, or dehydration in this sample. Cognitive impairment is relatively common in patients with heart failure. The Draw-a-Clock Test was most useful in detecting cognitive impairment, although it cannot be used to detect problems with verbal learning or delayed recall and should not be used as the sole screening method for patients with heart failure. Correlates of cognitive impairment require further study.

  15. Validation of serological tests for the detection of antibodies against Treponema pallidum in nonhuman primates.

    PubMed

    Knauf, Sascha; Dahlmann, Franziska; Batamuzi, Emmanuel K; Frischmann, Sieghard; Liu, Hsi

    2015-03-01

    There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs) and two non-treponemal tests (NTTs) were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis) from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA) was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG), however, could be considered as a confirmatory test.

  16. Giardiasis and Poor Vitamin A Status among Aboriginal School Children in Rural Malaysia

    PubMed Central

    Al-Mekhlafi, Hesham M.; Surin, Johari; Sallam, Atiya A.; Abdullah, Ariffin W.; Mahdy, Mohammed A. K.

    2010-01-01

    A cross-sectional study was carried out on 241 primary schoolchildren in Pahang, Malaysia to update their vitamin A status and to investigate the association of poor vitamin A status with their health and socioeconomic factors. All children were screened for intestinal parasitic infections. Blood samples were collected and vitamin A status was assessed. Socioeconomic data were collected by using pre-tested questionnaires. The results showed that 66 (27.4%) children had low serum retinol levels (< 0.70 μmol/L). Giardiasis and severe ascariasis were significantly associated with low serum retinol levels (P = 0.004 and P = 0.018, respectively). Logistic regression confirmed the significant association of giardiasis with low serum retinol (odds ratio = 2.7, 95% confidence interval = 1.3–5.5). In conclusion, vitamin A deficiency is still a public health problem in rural Malaysia. Vitamin A supplementation and treatment of intestinal parasitic infections should be distributed periodically to these children to improve their health and nutritional status. PMID:20810815

  17. Association between serum uric acid levels and obesity among university students (China).

    PubMed

    Duan, Ying; Liang, Wei; Zhu, Lijun; Zhang, Ting; Wang, Linghong; Nie, Zhognhua; Chen, Yan; He, Lianping; Jin, Yuelong; Yao, Yingshui

    2015-06-01

    To evaluate the association between serum uric acid and obesity among university students who participated in routine health screening in 2013. In this cross-sectional study, 3529 subjects were analyzed. Obesity categories were classified by BMI levels references in China. And serum uric acid levels were classified by serum uric acid quartiles. Two-sample T-test and Wilcoxon Rank sum test were used to compare age, biochemical and anthropometric parameters of subjects of two genders. Rank correlation used to analyze relationship between serum uric acid and obesity. There were 1285 males (mean age, 19.8 ± 1.3 years) and 2244 females (mean age, 19.9 ± 1.3 years) in this study. Association between 2nd serum uric acid quartile and normal in male are significant and coefficient was 0.519. The 3rd serum uric acid quartile and normal in female was associated significantly (r = 0.173, p = 0.010). And associations between overweight and 3rd and 4th serum uric acid quartiles in female were significant (r = 0.128, p = 0.038 in 1st quartile and r = 0.282, p = 0.004 in 4th quartile). The 4th serum uric acid quartile and Obesity in two gender groups were significantly associated (r = 0.291, p = 0.000 in male and r = 0.484, p = 0.001 in female). High serum uric acid was positively associated with obesity in overweight and obesity group. However, the association was weak between two variables because serum uric acid influenced obesity with other related factors together. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  18. SERUM BIOMARKERS OF AGING IN THE BROWN NORWAY RAT

    EPA Science Inventory

    Serum biomarkers to identify susceptibility to disease in aged humans are well researched. On the other hand, our understanding of biomarkers in animal models of aging is limited. Hence, we applied a commercially available panel of 58 serum analytes to screen for possible biomark...

  19. What is the true clinical relevance of Simkania negevensis and other emerging Chlamydiales members?

    PubMed

    Vouga, M; Kebbi-Beghdadi, C; Liénard, J; Baskin, L; Baud, D; Greub, G

    2018-05-01

    Waddlia   chondrophila and Simkania negevensis are emerging Chlamydia- related bacteria. Similar to the pathogenic organisms Chlamydia pneumoniae and Chlamydia trachomatis, these emerging bacteria are implicated in human genital infections and respiratory diseases. We used a screening strategy based on a newly developed S. negevensis -specific quantitative real-time PCR (qPCR) and a pan- Chlamydiales qPCR. We could not detect S. negevensis in 458 respiratory, genitourinary, cardiac and hepatic samples tested. One urethral swab was positive for W. chondrophila. We observed a low prevalence of Chlamydiales in respiratory samples (1/200, 0.5%), which suggests that C. pneumoniae is an uncommon respiratory pathogen. Furthermore, we screened 414 human serum samples from Switzerland, England and Israel and observed a low prevalence (<1%) of exposure to S. negevensis. Conversely, humans were commonly exposed to W. chondrophila, with seroprevalences ranging from 8.6% to 32.5%. S. negevensis is not a clinically relevant pathogen, but further research investigating the role of W. chondrophila is needed.

  20. Annual Research Progress Report, Fiscal Year 1980,

    DTIC Science & Technology

    1980-10-01

    Uric Acid Levels at 36 Weeks Gestation as 45 Screening Test for Preeclampsia as an Aid to Further Manage- ment. (0) DEPARTMENT OF PSYCHIATRY...Investigators: CPT Ellis M. Knight, MC Key Words: Serum Uric Acid Preeclampsia Accumulative MEDCASE Est Accumulative Periodic Ap-roved for continuation...Cost: 0 OMA Cost: 0 Review Results Study Objective: To demonstrate that: A. Serum uric acid level is a simple specific screening test for preeclampsia

  1. Searching for microbial protein over-expression in a complex matrix using automated high throughput MS-based proteomics tools.

    PubMed

    Akeroyd, Michiel; Olsthoorn, Maurien; Gerritsma, Jort; Gutker-Vermaas, Diana; Ekkelkamp, Laurens; van Rij, Tjeerd; Klaassen, Paul; Plugge, Wim; Smit, Ed; Strupat, Kerstin; Wenzel, Thibaut; van Tilborg, Marcel; van der Hoeven, Rob

    2013-03-10

    In the discovery of new enzymes genomic and cDNA expression libraries containing thousands of differential clones are generated to obtain biodiversity. These libraries need to be screened for the activity of interest. Removing so-called empty and redundant clones significantly reduces the size of these expression libraries and therefore speeds up new enzyme discovery. Here, we present a sensitive, generic workflow for high throughput screening of successful microbial protein over-expression in microtiter plates containing a complex matrix based on mass spectrometry techniques. MALDI-LTQ-Orbitrap screening followed by principal component analysis and peptide mass fingerprinting was developed to obtain a throughput of ∼12,000 samples per week. Alternatively, a UHPLC-MS(2) approach including MS(2) protein identification was developed for microorganisms with a complex protein secretome with a throughput of ∼2000 samples per week. TCA-induced protein precipitation enhanced by addition of bovine serum albumin is used for protein purification prior to MS detection. We show that this generic workflow can effectively reduce large expression libraries from fungi and bacteria to their minimal size by detection of successful protein over-expression using MS. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. A Pilot Study of Circulating MicroRNA-125b as a Diagnostic and Prognostic Biomarker for Epithelial Ovarian Cancer.

    PubMed

    Zhu, Tao; Gao, Wen; Chen, Xi; Zhang, Ying; Wu, Meijuan; Zhang, Ping; Wang, Shihua

    2017-01-01

    Early diagnosis of epithelial ovarian cancer is critical for patient survival. The objective of this pilot study is to identify a circulating micro (mi)RNA as a potential biomarker for epithelial ovarian cancer. A total of 135 epithelial ovarian cancer patients and 54 benign ovarian tumor patients were recruited for this study. Using customized TaqMan low density miRNA arrays, we first screened expression levels of 48 miRNAs in sera from 18 epithelial ovarian cancer patients and 16 benign ovarian tumor patients. The most significantly and differentially expressed miRNA was then further examined in all serum samples using real-time polymerase chain reaction. Its expression was further analyzed in relationship with clinicopathological factors and patient survival. Array screening data showed that expression levels of serum miRNA-20a, miRNA-125b, miRNA-126, miRNA-355, and let-7c were significantly different between malignant and benign ovarian tumor patients. Subsequent real-time polymerase chain reaction results showed that serum miRNA-125b levels were significantly higher in epithelial ovarian cancer patients compared to benign controls. Moreover, serum miRNA-125b levels were significantly higher in ovarian cancer patients in early stages I and II, and in patients having no residual tumor following surgery, but were not associated with differentiation and histological types of ovarian cancer. Notably, the higher level of miR-125b was significantly positively correlated with progression-free survival (P = 0.035) and marginally, with overall survival (P = 0.069). miRNA-125b plays an important role in the pathogenesis and progression of epithelial ovarian cancer. Circulating miRNA-125b has the potential to become a novel biomarker for early diagnosis and prognosis prediction of epithelial ovarian cancer.

  3. Genome-Scale Screen for DNA Methylation-Based Detection Markers for Ovarian Cancer

    PubMed Central

    Houshdaran, Sahar; Shen, Hui; Widschwendter, Martin; Daxenbichler, Günter; Long, Tiffany; Marth, Christian; Laird-Offringa, Ite A.; Press, Michael F.; Dubeau, Louis; Siegmund, Kimberly D.; Wu, Anna H.; Groshen, Susan; Chandavarkar, Uma; Roman, Lynda D.; Berchuck, Andrew; Pearce, Celeste L.; Laird, Peter W.

    2011-01-01

    Background The identification of sensitive biomarkers for the detection of ovarian cancer is of high clinical relevance for early detection and/or monitoring of disease recurrence. We developed a systematic multi-step biomarker discovery and verification strategy to identify candidate DNA methylation markers for the blood-based detection of ovarian cancer. Methodology/Principal Findings We used the Illumina Infinium platform to analyze the DNA methylation status of 27,578 CpG sites in 41 ovarian tumors. We employed a marker selection strategy that emphasized sensitivity by requiring consistency of methylation across tumors, while achieving specificity by excluding markers with methylation in control leukocyte or serum DNA. Our verification strategy involved testing the ability of identified markers to monitor disease burden in serially collected serum samples from ovarian cancer patients who had undergone surgical tumor resection compared to CA-125 levels. We identified one marker, IFFO1 promoter methylation (IFFO1-M), that is frequently methylated in ovarian tumors and that is rarely detected in the blood of normal controls. When tested in 127 serially collected sera from ovarian cancer patients, IFFO1-M showed post-resection kinetics significantly correlated with serum CA-125 measurements in six out of 16 patients. Conclusions/Significance We implemented an effective marker screening and verification strategy, leading to the identification of IFFO1-M as a blood-based candidate marker for sensitive detection of ovarian cancer. Serum levels of IFFO1-M displayed post-resection kinetics consistent with a reflection of disease burden. We anticipate that IFFO1-M and other candidate markers emerging from this marker development pipeline may provide disease detection capabilities that complement existing biomarkers. PMID:22163280

  4. Comparison of FTIR-ATR and Raman spectroscopy in determination of VLDL triglycerides in blood serum with PLS regression

    NASA Astrophysics Data System (ADS)

    Oleszko, Adam; Hartwich, Jadwiga; Wójtowicz, Anna; Gąsior-Głogowska, Marlena; Huras, Hubert; Komorowska, Małgorzata

    2017-08-01

    Hypertriglyceridemia, related with triglyceride (TG) in plasma above 1.7 mmol/L is one of the cardiovascular risk factors. Very low density lipoproteins (VLDL) are the main TG carriers. Despite being time consuming, demanding well-qualified staff and expensive instrumentation, ultracentrifugation technique still remains the gold standard for the VLDL isolation. Therefore faster and simpler method of VLDL-TG determination is needed. Vibrational spectroscopy, including FT-IR and Raman, is widely used technique in lipid and protein research. The aim of this study was assessment of Raman and FT-IR spectroscopy in determination of VLDL-TG directly in serum with the isolation step omitted. TG concentration in serum and in ultracentrifugated VLDL fractions from 32 patients were measured with reference colorimetric method. FT-IR and Raman spectra of VLDL and serum samples were acquired. Partial least square (PLS) regression was used for calibration and leave-one-out cross validation. Our results confirmed possibility of reagent-free determination of VLDL-TG directly in serum with both Raman and FT-IR spectroscopy. Quantitative VLDL testing by FT-IR and/or Raman spectroscopy applied directly to maternal serum seems to be promising screening test to identify women with increased risk of adverse pregnancy outcomes and patient friendly method of choice based on ease of performance, accuracy and efficiency.

  5. Evaluation of transmission infrared spectroscopy and digital and optical refractometers to identify low immunoglobulin G concentrations in alpaca serum

    PubMed Central

    Elsohaby, Ibrahim; Burns, Jennifer J.; Riley, Christopher B.; McClure, J. Trenton

    2017-01-01

    This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI). PMID:28725112

  6. Evaluation of transmission infrared spectroscopy and digital and optical refractometers to identify low immunoglobulin G concentrations in alpaca serum.

    PubMed

    Elsohaby, Ibrahim; Burns, Jennifer J; Riley, Christopher B; McClure, J Trenton

    2017-07-01

    This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI).

  7. In-depth molecular analysis of a small cohort of human and Aedes mosquito (adults and larvae) samples from Kolkata revealed absence of Zika but high prevalence of dengue virus.

    PubMed

    Sukla, Soumi; Ghosh, Anisa; Saha, Rajdeep; De, Abhishek; Adhya, Samit; Biswas, Subhajit

    2018-06-13

    Zika virus infections have recently been reported in many dengue-endemic areas globally. Both dengue (DENV) and Zika (ZIKV) virus are transmitted by Aedes mosquitoes, raising the possibility of mixed infections in both vector and host. We evaluated DENV and ZIKV prevalence in human and vector samples in Kolkata, a DENV-endemic city. Blood samples were collected from 70 patients presenting dengue-like fever symptoms at a hospital in Kolkata during 2015-16. Serum was obtained and tested for DENV infection by DENV NS1-based ELISA. Adult (n=8) and larval stages (n=12) of Aedes were also collected. A RT-PCR-based screening of both viruses supplemented by amplicon sequencing was performed. Of the 70 samples, 20 DENV NS1-positive serum samples were used for detailed molecular study for DENV infection. Eighteen of these (90 %) were positive by hemi-nested serotype-specific RT-PCR for DENV1/2/3, with four samples showing evidence of DENV2-3 or DENV1-3 mixed infection. None were ZIKV-positive using NS5 or ENV-based PCR, though weak amplification of a DENV1 NS5 sequence was detected in three serum samples indicating cross-reactivity of the primers. All mosquito samples were ZIKV-negative, whereas 5/8 (63 %) of adult mosquitoes and 11/12 (92 %) of larvae were DENV3-positive. Both host and vector samples showed absence of ZIKV but high prevalence of DENV. The high rate of infection of larvae with DENV is suggestive of trans-ovarial transmission that could contribute to the surge of human infections during each post-monsoon season. It would be important to guard against false positives using the available Zika-reporting primer sets.

  8. Seroprevalence of Brucella antibodies in camels in Katsina State, Nigeria.

    PubMed

    Salisu, U S; Kudi, C A; Bale, J O O; Babashani, M; Kaltungo, B Y; Saidu, S N A; Asambe, A; Baba, A Y

    2017-06-01

    A cross-sectional study was carried out to determine the status of Brucella infection in one-humped (Dromedary) camels in the North and Central senatorial districts of Katsina State, Nigeria. Nine hundred and eighty serum samples from live and slaughtered camels were tested. Modified Rose Bengal plate test (RBPT) and serum agglutination test (SAT) with ethylenediaminetetraacetic acid, (EDTA) were used as screening and standard tests, respectively. The prevalence of Brucella antibodies were 110 (11.2%) and 103 (10.5%) for RBPT and SAT, respectively. Of the 472 and 508 serum samples tested from the herds and abattoirs, respectively, 63 (13.3%) and 47 (9.3%) were positive by RBPT while 62 (13.1%) and 41 (8.1%) were positive by SAT, respectively. Based on the results, it was concluded that Brucella antibodies were present in camels in the study area. Poor management practices and mixing of camels with other species of livestock as well as unrestricted movement of camels were proposed to be the reasons for the prevalence of the disease in the study area. In view of the public health importance of the disease, it is recommended that there is the need to develop a strategic plan to decrease spread of brucellosis in the study area.

  9. Toxoplasma serotype is associated with development of ocular toxoplasmosis.

    PubMed

    Shobab, Leila; Pleyer, Uwe; Johnsen, Joerdis; Metzner, Sylvia; James, Erick R; Torun, N; Fay, Michael P; Liesenfeld, Oliver; Grigg, Michael E

    2013-11-01

    Worldwide, ocular toxoplasmosis (OT) is the principal cause of posterior uveitis, a severe, life-altering disease. A Toxoplasma gondii enzyme-linked immunoassay that detects strain-specific antibodies present in serum was used to correlate serotype with disease. Toxoplasma serotypes in consecutive serum samples from German uveitis patients with OT were compared with non-OT seropositive patients with noninfectious autoimmune posterior uveitis. OT patients were tested for association of parasite serotype with age, gender, location, clinical onset, size, visual acuity, or number of lesions (mean follow-up, 3.8 years) to determine association with recurrences. A novel, nonreactive (NR) serotype was detected more frequently in serum samples of OT patients (50/114, 44%) than in non-OT patients (4/56, 7%) (odds ratio, 10.0; 95% confidence interval 3.4-40.8; P < .0001). Non-OT patients were predominantly infected with Type II strains (39/56; 70%), consistent with expected frequencies in Central Europe. Among OT patients, those with NR serotypes experienced more frequent recurrences (P = .037). Polymerase chain reaction detected parasite DNA in 8/60 OT aqueous humor specimens but failed to identify Type II strain alleles. Toxoplasma NR and Type II serotypes predominate in German OT patients. The NR serotype is associated with OT recurrences, underscoring the value of screening for management of disease.

  10. Evaluation of a rapid agglutination method for detection of equine red cell surface antigens (Ca and Aa) as part of pretransfusion testing.

    PubMed

    Owens, Sean D; Snipes, Joy; Magdesian, K Gary; Christopher, Mary M

    2008-03-01

    Blood typing before transfusion minimizes the risk of transfusion reactions and prevents immunization of the recipient against incompatible RBC antigens. The major RBC antigens that warrant identification before packed RBC or whole blood transfusions in horses are Ca and Aa. Standard blood-typing protocols are time-consuming (2.5-3.0 hours) and impractical in emergency settings. The purpose of this study was to determine whether equine RBCs could be typed for Ca and Aa antigens using sera from horses with RBC antibodies in a modified rapid (15 minute) blood-typing protocol. Serum was obtained from a horse with anti-Ca antibodies and from another horse with anti-Aa antibodies. The presence of agglutinating antibodies was confirmed with antibody screening. Venous blood samples, collected in citrate-phosphate-dextrose, were obtained from 21 horses of various breeds. Samples were blood typed in the Veterinary Medical Teaching Hospital Hematology Laboratory using standard methodology. Washed RBCs from each of the 21 horses were incubated individually with anti-Ca and anti-Aa sera at dilutions of 1:4, 1:8, and 1:16 for 15 and 30 minutes at room temperature and 37 degrees C. Of the 21 horses, 13 were identified as Aa+/Ca+, four were Aa+/Ca-, two were Aa-/Ca+, and two were Aa-/Ca-. All 17 Aa-positive horses had a positive agglutination reaction at all dilutions of anti-Aa serum, incubation times, and temperatures, while all Aa-negative horses were negative. Each Ca-positive horse had a positive agglutination reaction at all incubation time points and temperatures up to the 1:16 dilution of the anti-Ca serum. All Ca-negative horses were negative at all times, temperatures, and dilutions of anti-Ca serum. Use of the modified protocol on 26 hospitalized horses resulted in accurate typing, based on complete antibody screens. These results support the hypothesis that equine RBCs can be blood typed using a rapid (15 minute) protocol, at room temperature, for the presence of Ca and Aa antigens using equine-derived antisera. This technique may be beneficial for pretransfusion testing of equine patients in an emergency setting.

  11. Piezoelectric microcantilever serum protein detector

    NASA Astrophysics Data System (ADS)

    Capobianco, Joseph A.

    The development of a serum protein detector will provide opportunities for better screening of at-risk cancer patients, tighter surveillance of disease recurrence and better monitoring of treatment. An integrated system that can process clinical samples for a number of different types of biomarkers would be a useful tool in the early detection of cancer. Also, screening biomarkers such as antibodies in serum would provide clinicians with information regarding the patient's response to treatment. Therefore, the goal of this study is to develop a sensor which can be used for rapid, all-electrical, real-time, label-fee, in-situ, specific quantification of cancer markers, e.g., human epidermal receptor 2 (Her2) or antibodies, in serum. To achieve this end, piezoelectric microcantilever sensors (PEMS) were constructed using an 8 mum thick lead magnesium niobate-lead titanate (PMN-PT) freestanding film as the piezoelectric layer. The desired limit of detection is on the order of pg/mL. In order to achieve this goal the higher frequency lateral extension modes were used. Also, as the driving and sensing of the PEMS is electrical, the PEMS must be insulated in a manner that allows it to function in aqueous solutions. The insulation layer must also be compatible with standardized bioconjugation techniques. Finally, detection of both cancer antigens and antibodies in serum was carried out, and the results were compared to a standard commercialized protocol. PEMS have demonstrated the capability of detecting Her2 at a concentration of 5 pg/mL in diluted human serum (1:40) in less than 1 hour. The approach can be easily translated into the clinical setting because the sensitivity is more than sufficient for monitoring prognosis of breast cancer patients. In addition to Her2 detection, antibodies in serum were assayed in order to demonstrate the feasibility of monitoring the immune response for antibody-dependent cellular cytotoxicity (ADCC) in patients on antibody therapies such as Herceptin and Cetuximab. The PEMS displayed a limit of detection of 100 fg/mL, which was 100 times lower than the current methods of protein detection in serum, such as ELISA. Furthermore, the sensitivity of the PEMS device allows it to be capable of determining the dissociation constant, K d, of selective receptors such as antibodies. Using the dose response trials of Her2, Kd has been deduced for H3 scFv, and Herceptin, a commercial antibody specific for Her2.

  12. Macro TSH in patients with subclinical hypothyroidism.

    PubMed

    Hattori, Naoki; Ishihara, Takashi; Yamagami, Keiko; Shimatsu, Akira

    2015-12-01

    TSH is a sensitive indicator of thyroid function. In subclinical hypothyroidism, however, serum TSH concentrations are elevated despite normal thyroid hormone levels, and macro TSH is one of the causes. This study aimed to clarify the prevalence and nature of macro TSH in patients with subclinical hypothyroidism. We conducted a 2-year cross-sectional observational study. We included 681 patients with subclinical hypothyroidism and 38 patients with overt hypothyroidism (controls). Macro TSH was screened by polyethylene glycol (PEG) method and analysed by gel filtration chromatography and bioassays. Among 681 serum samples, 117 exhibited PEG-precipitable TSH ratios greater than 75% (mean + 1·5 SD in controls) and were subjected to gel filtration chromatography. TSH was eluted at a position greater than 100 kDa in 11 patients with subclinical hypothyroidism (1·62%); these patients were diagnosed with macro TSH. The nature of macro TSH included eight anti-TSH autoantibodies of IgG class, two non-IgG-associated and one human anti-mouse antibody (HAMA). Macro TSH showed low bioactivity. Macro TSH was heterogeneous, but it is mostly comprised of TSH and anti-TSH autoantibodies. When PEG-precipitable TSH exceeds 90% in serum samples with TSH above 10 mU/l, clinicians should strongly suspect the presence of macro TSH and confirm it by gel chromatography. Because macro TSH exhibited low bioactivity, thyroid hormone replacement therapy may not be required in patients with subclinical hypothyroidism due to macro TSH except for those with high serum free TSH levels. © 2014 John Wiley & Sons Ltd.

  13. Diagnostic reliability of an immunochromatographic test for Chagas disease screening at a primary health care centre in a rural endemic area

    PubMed Central

    Mendicino, Diego; Stafuza, Mariana; Colussi, Carlina; del Barco, Mónica; Streiger, Mirtha; Moretti, Edgardo

    2014-01-01

    Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel. PMID:25466624

  14. First evidence of dengue infection in domestic dogs living in different ecological settings in Thailand.

    PubMed

    Thongyuan, Suporn; Kittayapong, Pattamaporn

    2017-01-01

    Dengue is a vector-borne disease transmitted by Aedes mosquitoes. It is considered an important public health problem in many countries worldwide. However, only a few studies have been conducted on primates and domestic animals that could potentially be a reservoir of dengue viruses. Since domestic dogs share both habitats and vectors with humans, this study aimed to investigate whether domestic dogs living in different ecological settings in dengue endemic areas in Thailand could be naturally infected with dengue viruses. Serum samples were collected from domestic dogs in three different ecological settings of Thailand: urban dengue endemic areas of Nakhon Sawan Province; rubber plantation areas of Rayong Province; and Koh Chang, an island tourist spot of Trat Province. These samples were screened for dengue viral genome by using semi-nested RT-PCR. Positive samples were then inoculated in mosquito and dog cell lines for virus isolation. Supernatant collected from cell culture was tested for the presence of dengue viral genome by semi-nested RT-PCR, then double-strand DNA products were double-pass custom-sequenced. Partial nucleotide sequences were aligned with the sequences already recorded in GenBank, and a phylogenetic tree was constructed. In the urban setting, 632 domestic dog serum samples were screened for dengue virus genome by RT-PCR, and six samples (0.95%) tested positive for dengue virus. Four out of six dengue viruses from positive samples were successfully isolated. Dengue virus serotype 2 and serotype 3 were found to have circulated in domestic dog populations. One of 153 samples (0.65%) collected from the rubber plantation area showed a PCR-positive result, and dengue serotype 3 was successfully isolated. Partial gene phylogeny revealed that the isolated dengue viruses were closely related to those strains circulating in human populations. None of the 71 samples collected from the island tourist spot showed a positive result. We concluded that domestic dogs can be infected with dengue virus strains circulating in dengue endemic areas. The role of domestic dogs in dengue transmission needs to be further investigated, i.e., whether they are potential reservoirs or incidental hosts of dengue viruses.

  15. Early Detection of Foot-And-Mouth Disease Virus from Infected Cattle Using A Dry Filter Air Sampling System.

    PubMed

    Pacheco, J M; Brito, B; Hartwig, E; Smoliga, G R; Perez, A; Arzt, J; Rodriguez, L L

    2017-04-01

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to the aerogenous nature of the virus. In the current study, air from rooms housing individual (n = 17) or two groups (n = 4) of cattle experimentally infected with FDMV A24 Cruzeiro of different virulence levels was sampled to assess the feasibility of applying air sampling as a non-invasive, screening tool to identify sources of FMDV infection. Detection of FMDV RNA in air was compared with first detection of clinical signs and FMDV RNA levels in serum and oral fluid. FMDV RNA was detected in room air samples 1-3 days prior (seven animals) or on the same day (four animals) as the appearance of clinical signs in 11 of 12 individually housed cattle. Only in one case clinical signs preceded detection in air samples by one day. Overall, viral RNA in oral fluid or serum preceded detection in air samples by 1-2 days. Six individually housed animals inoculated with attenuated strains did not show clinical signs, but virus was detected in air in one of these cases 3 days prior to first detection in oral fluid. In groups of four cattle housed together, air detection always preceded appearance of clinical signs by 1-2 days and coincided more often with viral shedding in oral fluid than virus in blood. These data confirm that air sampling is an effective non-invasive screening method for detecting FMDV infection in confined to enclosed spaces (e.g. auction barns, milking parlours). This technology could be a useful tool as part of a surveillance strategy during FMD prevention, control or eradication efforts. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  16. The mimic epitopes of Mycobacterium tuberculosis screened by phage display peptide library have serodiagnostic potential for tuberculosis.

    PubMed

    Wang, Li; Deng, Xiangying; Liu, Haican; Zhao, Lanhua; You, Xiaolong; Dai, Pei; Wan, Kanglin; Zeng, Yanhua

    2016-11-01

    Mycobacterium tuberculosis is an obligate pathogenic bacterial species in the family of Mycobacteriaceae and attracts excessive immune responses which cause pathology of the lungs in active tuberculosis. The lack of more sensitive and effective diagnosis reagents advocates a further recognition for the fast diagnostic and immunological measures for tuberculosis. Here, two 12-mer peptides with core sequences of SVSVGMKPSPRP (CS1) and TMGFTAPRFPHY (CS2) were screened from a phage display random peptide library using the purified mixed tuberculosis-positive serum as a target. Enzyme-linked immunosorbent assay (ELISA) and dot immunobinding assay verified that positive phages exhibited strong binding affinity to mixed tuberculosis-positive serum. BLAST analysis showed that the two sequences may be mimotopes of the Mycobacterium tuberculosis The diagnostic potential for two synthetic mimotope peptides CS1 and CS2 was evaluated using different panels of serum samples (n = 181) by ELISA, and the diagnostic parameters were calculated. CS1 and CS2 achieved sensitivity of 89.41% and 85.88%, and specificities were 90.63% and 87.50%, respectively. We hypothesized that the diagnostic based on CS1 and CS2 may become a promising strategy to enhance the detection of Mycobacterium tuberculosis infection due to higher specificity and sensitivity. Therefore, CS1 and CS2 may possess potentials to provide an experimental basis for the diagnosis of tuberculosis. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Vaginal cytokines do not correlate with postmenopausal vulvovaginal symptoms.

    PubMed

    Kollmann, Zahraa; Bersinger, Nick; von Wolff, Michael; Thurman, Andrea R; Archer, David F; Stute, Petra

    2015-04-01

    Exploratory pilot study to determine the correlation between postmenopausal vulvovaginal symptoms and vaginal cytokine levels. Postmenopausal women (n = 34) not using menopausal hormone therapy and presenting with or without symptoms of vulvovaginal irritation were screened. Each participant underwent a vaginal examination and screening for vaginitis. A cervicovaginal lavage (CVL) with sterile saline and a peripheral blood sample were obtained. Main outcome measures were assessed by Luminex® X-map method on the Bio-Plex® platform. Main outcome measures were cervicovaginal and serum interleukin (IL)-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES level. Cervicovaginal cytokines were adjusted to total protein concentration [pg/mcg protein]. Twenty-six postmenopausal women were enrolled (symptomatic: n = 15; asymptomatic: n = 11). There were no significant differences between groups: age, age at menopause, vaginal pH and all CVL and serum cytokines (IL-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES). GM-CSF was the most abundant vaginal cytokine (symptomatic: 146.5 ± 165.6 pg/mcg protein; asymptomatic: 146.0 ± 173.5 pg/mcg protein; p = 0.99). Postmenopausal vulvovaginal symptoms did not correlate with vaginal inflammatory marker. There was no difference in serum or CVL cytokines between symptomatic and asymptomatic postmenopasual women. Vaginal symptoms after menopause are not related to the vaginal cytokine changes associated with loss of estrogen.

  18. Evaluation of the highly sensitive chemiluminescent enzyme immunoassay "Lumipulse HBsAg-HQ" for hepatitis B virus screening.

    PubMed

    Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo

    2017-10-06

    Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.

  19. Rapid Immunochromatographic Detection of Serum Anti-α-Galactosidase A Antibodies in Fabry Patients after Enzyme Replacement Therapy

    PubMed Central

    Nakano, Sachie; Tsukimura, Takahiro; Togawa, Tadayasu; Ohashi, Toya; Kobayashi, Masahisa; Takayama, Katsuyoshi; Kobayashi, Yukuharu; Abiko, Hiroshi; Satou, Masatsugu; Nakahata, Tohru; Warnock, David G.; Sakuraba, Hitoshi; Shibasaki, Futoshi

    2015-01-01

    We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy. PMID:26083343

  20. Radioimmunoassay of lysergic acid diethylamide (LSD) in serum and urine by using antisera of different specificities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Fletcher, S.M.; Moffat, A.C.

    We raised high-titre antisera to two LSD-bovine serum albumin conjugates, one linked via the indole nitrogen, the other via the amide side-chain. The antisera were specific for different parts of the LSD molecule, as demonstrated by cross-reactivity studies with LSD, its metabolites, ergot alkaloids, and closely related compounds. The antisera were used to develop a double-antibody radioimmunoassay with a detection limit of about 0.4 ..mu..g of LSD per liter of unextracted urine or serum. We saw no nonspecific interference by urine, serum, or from a series of commonly used drugs. There was good correlation between immunoassay values obtained with themore » two antisera (r = 0.91). However, the antiserum linked via the indole nitrogen gave consistently higher results for samples from persons who had taken LSD, owing to greater cross-reactivity with LSD metabolites. Radioimmunoassay by use of two such antisera is a more specific screening procedure for LSD abuse than has been available previously. In addition, antisera cross-reacting with LSD metabolites allow measurement of these compounds, for which there is no satisfactory method at the concentrations found in biological fluids in man.« less

  1. [Identification of differential proteins of serum in the patients suffering from coal-burning arsenism].

    PubMed

    Han, Bing; Yang, Qin; Luo, Xin-hua; He, Xiao-fei; Wu, Jun; Cheng, Ming-liang

    2009-06-02

    To compare and analyze the differential expression of proteins between coal-burning arsenism serum and normal human serum and identify the proteins related with arseniasis caused by coal-burning. Serum samples were collected from 6 normal subjects and 6 patients suffering from coal-burning arsenism. 2-DE was performed to separate serum proteins. After silver staining, the differential expression of proteins was analyzed and then identified by matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). There were an average of 779 +/- 35 spots and 865 +/- 30 spots on 2-DE matching of two groups and the matching rate was 90.1% between two groups. From these two groups, 60 different protein spots were identified. Up-regulated expression was observed in 25 proteins and down-regulated expression in 35 proteins in the patient serum group. Among which 35 with differential expression above three times were singled out and MALDI-TOF-MS analysis was carried out on them. Thirteen proteins were identified, including keratin 10, apolipoprotein A-V, transferrin, alpha-1-antitrypsin, human zinc-alpha-2-glycoprotein, mitogen-activated protein kinase 3, vacuolar protein sorting 33A, O-linked GlcNAc transferase and etc. Up-regulated expression was observed in 5 proteins and down-regulated expression in 8 proteins in the patient serum group. The well-resolved and reproducible 2-DE serum patterns of patients suffering from coal-burning arsenism were established and some differentially expressed proteins characterized. These data will be used to screen the biomarker and to further study arseniasis caused by coal-burning.

  2. Evaluation of an automated connective tissue disease screening assay in Korean patients with systemic rheumatic diseases

    PubMed Central

    Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong

    2017-01-01

    This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE. PMID:28273146

  3. Evaluation of an automated connective tissue disease screening assay in Korean patients with systemic rheumatic diseases.

    PubMed

    Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong

    2017-01-01

    This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.

  4. Brucellosis in pregnant women from Pakistan: an observational study.

    PubMed

    Ali, Shahzad; Akhter, Shamim; Neubauer, Heinrich; Scherag, André; Kesselmeier, Miriam; Melzer, Falk; Khan, Iahtasham; El-Adawy, Hosny; Azam, Asima; Qadeer, Saima; Ali, Qurban

    2016-09-02

    Brucella species occasionally cause spontaneous human abortion. Brucella can be transmitted commonly through the ingestion of raw milk or milk products. The objective of this study was to determine the sero-prevalence of and to identify potential risk factors for brucellosis in pregnant women from Rawalpindi, Pakistan. We conducted a cross-sectional study at the Gynecology Outdoor Patient department of the Benazir Bhutto Hospital, Rawalpindi, Pakistan from March to June 2013. Data related to potential risk factors and clinical history was collected by individual interviews on the blood sampling day. The 429 serum samples collected were initially screened by Rose Bengal Plate Agglutination test for the detection of Brucella antibodies. We applied standard descriptive statistics and logistic regression analyses. Twenty five (5.8 %; 95 % confidence interval (CI): 3.8 % -8.5 %) serum samples were found to be seropositive. Brucellosis-related clinical symptoms were recorded in various seropositive cases. Animal contact, raw milk consumption, having an abortion history and the experience of an intrauterine fetal death were associated with seropositivity for brucellosis in univariate analyses (all p <0.05). In multiple logistic regression models only the contact with animals remained as independent and robust risk factor (odds ratio 5.21; 95 % CI: 1.88-13.75; p = 0.001) for seropositivity. Brucellosis is a serious threat for pregnant women and their unborn children in Pakistan. Pregnant women having brucellosis-related symptoms or previous history of abortions, miscarriages, intrauterine fetal death and other brucellosis-related manifestations should be screened for brucellosis - especially those exposed to animals given the increased risk - and medication should be administered according to state of the art.

  5. A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation.

    PubMed

    Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S

    2014-12-01

    Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.

  6. Multiplexed Anti-Toxoplasma IgG, IgM, and IgA Assay on Plasmonic Gold Chips: towards Making Mass Screening Possible with Dye Test Precision

    PubMed Central

    Li, Xiaoyang; Pomares, Christelle; Gonfrier, Géraldine; Koh, Byumseok; Zhu, Shoujun; Gong, Ming

    2016-01-01

    Toxoplasmosis is an infection caused by the protozoan parasite Toxoplasma gondii that can lead to severe sequelae in the fetus during pregnancy. Definitive serologic diagnosis of the infection during gestation is made mostly by detecting T. gondii-specific antibodies, including IgG and IgM, individually in a single serum sample by using commercially available kits. The IgA test is used by some laboratories as an additional marker of acute infection. Most of the commercial tests have failed to reach 100% correlation with the reference method, the Sabin-Feldman dye test for the detection of Toxoplasma IgG antibodies. For Toxoplasma IgM and IgA antibodies, there is no reference method and their evaluation is done by comparing the results of one assay to those of another. There is a need for multiplexed assay platforms, as the serological diagnosis of T. gondii infection does not rely on the detection of a single Ig subtype. Here we describe the development of a plasmonic gold chip with vast fluorescence enhancement in the near-infrared region for simultaneous detection of IgG, IgM, and IgA antibodies against T. gondii in an ∼1-μl serum or whole-blood sample. When 168 samples were tested on this platform, IgG antibody detection sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were all 100%. IgM antibody detection achieved 97.6% sensitivity and 96.9% specificity with a 90.9% PPV and a 99.2% NPV. Thus, the nanoscience-based plasmonic gold platform enables a high-performance, low-cost, multiplexed assay requiring ultrasmall blood volumes, paving the way for the implementation of universal screening for toxoplasmosis infection during gestation. PMID:27008879

  7. Evaluation of inapparent nosocomial severe acute respiratory syndrome coronavirus infection in Vietnam by use of highly specific recombinant truncated nucleocapsid protein-based enzyme-linked immunosorbent assay.

    PubMed

    Yu, Fuxun; Le, Mai Quynh; Inoue, Shingo; Thai, Hong Thi Cam; Hasebe, Futoshi; Del Carmen Parquet, Maria; Morita, Kouichi

    2005-07-01

    Severe acute respiratory syndrome (SARS) is a recently emerged human disease associated with pneumonia. Inapparent infection with SARS coronavirus (CoV) is not well characterized. To develop a safe, simple, and reliable screening method for SARS diagnosis and epidemiological study, two recombinant SARS-CoV nucleocapsid proteins (N' protein and (N)Delta(121) protein) were expressed in Escherichia coli, purified by affinity chromatography, and used as antigens for indirect, immunoglobulin G enzyme-linked immunosorbent assays (ELISA). Serum samples collected from healthy volunteers and SARS patients in Vietnam were used to evaluate the newly developed methods. The N' protein-based ELISA showed a highly nonspecific reaction. The (N)Delta(121) protein-based ELISA, with a nonspecific reaction drastically reduced compared to that of the nearly-whole-length N' protein-based ELISA, resulted in higher rates of positive reactions, higher titers, and earlier detection than the SARS-CoV-infected cell lysate-based ELISA. These results indicate that our newly developed SARS-CoV (N)Delta(121) protein-based ELISA is not only safe but also a more specific and more sensitive method to diagnose SARS-CoV infection and hence a useful tool for large-scale epidemiological studies. To identify inapparent SARS-CoV infections, serum samples collected from health care workers (HCWs) in Vietnam were screened by the (N)Delta(121) protein-based ELISA, and positive samples were confirmed by a virus neutralization test. Four out of 149 HCWs were identified to have inapparent SARS-CoV infection in Vietnam, indicating that subclinical SARS-CoV infection in Vietnam is rare but does exist.

  8. Evaluation of Inapparent Nosocomial Severe Acute Respiratory Syndrome Coronavirus Infection in Vietnam by Use of Highly Specific Recombinant Truncated Nucleocapsid Protein-Based Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Yu, Fuxun; Le, Mai Quynh; Inoue, Shingo; Thai, Hong Thi Cam; Hasebe, Futoshi; del Carmen Parquet, Maria; Morita, Kouichi

    2005-01-01

    Severe acute respiratory syndrome (SARS) is a recently emerged human disease associated with pneumonia. Inapparent infection with SARS coronavirus (CoV) is not well characterized. To develop a safe, simple, and reliable screening method for SARS diagnosis and epidemiological study, two recombinant SARS-CoV nucleocapsid proteins (N′ protein and NΔ121 protein) were expressed in Escherichia coli, purified by affinity chromatography, and used as antigens for indirect, immunoglobulin G enzyme-linked immunosorbent assays (ELISA). Serum samples collected from healthy volunteers and SARS patients in Vietnam were used to evaluate the newly developed methods. The N′ protein-based ELISA showed a highly nonspecific reaction. The NΔ121 protein-based ELISA, with a nonspecific reaction drastically reduced compared to that of the nearly-whole-length N′ protein-based ELISA, resulted in higher rates of positive reactions, higher titers, and earlier detection than the SARS-CoV-infected cell lysate-based ELISA. These results indicate that our newly developed SARS-CoV NΔ121 protein-based ELISA is not only safe but also a more specific and more sensitive method to diagnose SARS-CoV infection and hence a useful tool for large-scale epidemiological studies. To identify inapparent SARS-CoV infections, serum samples collected from health care workers (HCWs) in Vietnam were screened by the NΔ121 protein-based ELISA, and positive samples were confirmed by a virus neutralization test. Four out of 149 HCWs were identified to have inapparent SARS-CoV infection in Vietnam, indicating that subclinical SARS-CoV infection in Vietnam is rare but does exist. PMID:16002634

  9. Trend of human brucellosis over a decade at tertiary care centre in North Karnataka.

    PubMed

    Patil, D P; Ajantha, G S; Shubhada, C; Jain, P A; Kalabhavi, A; Shetty, P C; Hosamani, M; Appannanavar, S; Kulkarni, R D

    2016-01-01

    Brucellosis is an important zoonotic disease. India having a major agrarian population is expected to have a higher prevalence. However, due to lack of laboratory facility or awareness among clinicians, the disease is largely underreported. The aim of this study was to know the prevalence and trend of human brucellosis over a decade, in patients attending a teaching hospital in North Karnataka, and to understand their geographical distribution. The study was conducted from January 2006 to December 2015 at a tertiary care teaching hospital in North Karnataka. A total of 3610 serum samples were evaluated from suspected cases of brucellosis. All serum samples were initially screened by Rose Bengal plate test, and positive samples were further analysed by Serum agglutination test (SAT) using standard Brucella abortus antigen from Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India. A titre above or equal to 1:80 IU/ml was considered as positive. Demographic data such as age, sex and native place of these patients were also analysed. We observed that human brucellosis is present in North Karnataka. The overall seropositivity of brucellosis in suspected cases was 5.1%. The positive titres ranged from 1:80 to 163,840 IU/ml. The majority of the patients were from Gadag, Koppal and Haveri districts of North Karnataka. Our study confirms the presence of human brucellosis in the northern part of Karnataka. Further studies to understand the prevalence of animal brucellosis in these areas will help in implementing prevention measures.

  10. A rapid fluorescence assay for danofloxacin in beef muscle: effect of muscle type on limit of quantitation.

    PubMed

    Schneider, Marilyn J

    2008-08-01

    A simple, rapid fluorescence screening assay was applied to the analysis of beef muscle for danofloxacin at the U.S. tolerance level of 200 ng/g. Muscle samples were homogenized in acetic acid-acetonitrile, the resultant mixture centrifuged, and fluorescence of the supernatants was then measured. The significant difference between the fluorescence of control muscle sample extracts and extracts of samples fortified at 200 ng/g allowed for successful discrimination between the samples. Setting a threshold level at the average 200 ng/g fortified sample extract fluorescence -3sigma allowed for identification of potentially violative samples. Successful analysis of a group of blind fortified samples over a range of concentrations was accomplished in this manner, without any false-negative results. The limits of quantitation for danofloxacin, as well as enrofloxacin, using this assay were determined in three types of beef muscle (hanging tenderloin, neck, and eye round steak), as well as in serum. Significant differences in limits of quantitation were found among the three different muscle types examined, with hanging tenderloin muscle providing the lowest value. This work not only shows the potential for use of the fluorescence screening assay as an alternative to currently used microbial or antibody-based assays for the analysis of danofloxacin in beef muscle, but also suggests that assays using beef muscle may vary in performance depending on the specific muscle selected for analysis.

  11. New method of paired thyrotropin assay as a screening test for neonatal hypothyroidism. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyai, K.; Oura, T.; Kawashima, M.

    1978-11-01

    A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4 to 7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cut-off points were tested. On the basismore » of reference blood samples (serum levels of TSH, 80 ..mu..U/ml in system A and 40 ..mu..U/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.« less

  12. Diagnostic Application of IS900 PCR Using Blood as a Source Sample for the Detection of Mycobacterium avium Subspecies Paratuberculosis in Early and Subclinical Cases of Caprine Paratuberculosis.

    PubMed

    Singh, P K; Singh, S V; Kumar, H; Sohal, J S; Singh, A V

    2010-01-01

    Efficacy of IS900 blood PCR was evaluated for the presence of MAP infection. Serum, fecal, and blood samples of kids, young, and adult goats from farm and farmer's herds in Mathura district were also screened by ELISA, microscopy and culture. Of 111 goats (kids: 40, young: 14, adults: 57) screened, 77.5% were positive by blood PCR. Of 76 goats, 90.8% (kids: 87.5% and adults: 94.4%) were positive by PCR. From 21 kids and 14 young goats, 42.8 and 57.1% were positive. gDNA from goats was genotyped as MAP "Indian Bison type". Of 21 fecal samples of kids examined by microscopy, 66.7% were positive. In ELISA, 9.5 and 57.1% kids were positives as "type I" and "type II" reactors, respectively. Screening 14 young goats by culture of blood clots, 28.6% were positive. Agreement was substantial between PCR and microscopy. It was fair and moderate when PCR and microscopy were compared with type I and type II reactors, respectively. Presence of MAP in non-clinical kids and young goats indicate early or subclinical infection. Blood PCR was rapid, sensitive, and specific assay for detection of MAP in any stage (early, subclinical, and clinical) and age (kids, young, and adult) of goats.

  13. The use of the osmole gap as a screening test for the presence of exogenous substances.

    PubMed

    Purssell, Roy A; Lynd, Larry D; Koga, Yoshikata

    2004-01-01

    The rapid and accurate diagnosis of toxic alcohol poisoning due to methanol (methyl alcohol) [MeOH] and ethylene glycol (EG), is paramount in preventing serious adverse outcomes. The quantitative measurement of specific serum levels of these substances using gas chromatography is expensive, time consuming and generally only available at major tertiary-care facilities. Therefore, because these toxic substances are osmotically active and the measurement of serum osmolality is easily performed and more readily available, the presence of an osmole gap (OG) has been adopted as an alternative screening test. By definition, the OG is the difference between the measured serum osmolality determined using the freezing point depression (Osm(m)) and the calculated serum molarity (Mc), which is estimated from the known and readily measurable osmotically active substances in the serum, in particular sodium, urea, glucose, and potassium and ethanol (alcohol). Thus, the OG=Osm(m)-Mc, and an OG above a specific threshold (the threshold of positivity) suggests the presence of unmeasured osmotically active substances, which could be indicative of a toxic exposure. The objectives of this study were to review the principles of evaluating screening tests, the theory behind the OG as a screening test and the literature upon which the adoption of the OG as a screening test has been based. This review revealed that there have been numerous equations derived and proposed for the estimation of the Mc, with the objective of developing empirical evidence of the best equation for the determination of the OG and ultimately the utility of OG as a screening test. However, the methods and statistical analysis employed have generally been inconsistent with recommended guidelines for screening test evaluation and although many equations have been derived, they have not been appropriately validated. Specific evidence of the clinical utility of the OG requires that a threshold of positivity be definitively established, and the sensitivity and specificity of the OG in patients exposed to either EG or MeOH be measured. However, the majority of studies to date have only evaluated the relationship between the Osm(m) (mmol/kg H2O) and the Mc (mmol/L) in patients that have not been exposed to either MeOH or EG. While some studies have evaluated the relationship between the OG and serum ethanol concentration, these findings cannot be extrapolated to the use of the OG to screen for toxic alcohol exposure. This review shows that there has not been an appropriately designed empirical evaluation of the diagnostic utility of the OG and that its clinical utility remains hypothetical, having been theoretically extrapolated from the non-poisoned population.

  14. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    EPA Pesticide Factsheets

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  15. High-Density Peptide Microarray Analysis of IgG Autoantibody Reactivities in Serum and Cerebrospinal Fluid of Multiple Sclerosis Patients*

    PubMed Central

    Hecker, Michael; Fitzner, Brit; Wendt, Matthias; Lorenz, Peter; Flechtner, Kristin; Steinbeck, Felix; Schröder, Ina; Thiesen, Hans-Jürgen; Zettl, Uwe Klaus

    2016-01-01

    Intrathecal immunoglobulin G (IgG) synthesis and oligoclonal IgG bands in cerebrospinal fluid (CSF) are hallmarks of multiple sclerosis (MS), but the antigen specificities remain enigmatic. Our study is the first investigating the autoantibody repertoire in paired serum and CSF samples from patients with relapsing-remitting MS (RRMS), primary progressive MS (PPMS), and other neurological diseases by the use of high-density peptide microarrays. Protein sequences of 45 presumed MS autoantigens (e.g. MOG, MBP, and MAG) were represented on the microarrays by overlapping 15mer peptides. IgG reactivities were screened against a total of 3991 peptides, including also selected viral epitopes. The measured antibody reactivities were highly individual but correlated for matched serum and CSF samples. We found 54 peptides to be recognized significantly more often by serum or CSF antibodies from MS patients compared with controls (p values <0.05). The results for RRMS and PPMS clearly overlapped. However, PPMS patients presented a broader peptide-antibody signature. The highest signals were detected for a peptide mapping to a region of the Epstein-Barr virus protein EBNA1 (amino acids 392–411), which is homologous to the N-terminal part of human crystallin alpha-B. Our data confirmed several known MS-associated antigens and epitopes, and they delivered additional potential linear epitopes, which await further validation. The peripheral and intrathecal humoral immune response in MS is polyspecific and includes antibodies that are also found in serum of patients with other diseases. Further studies are required to assess the pathogenic relevance of autoreactive and anti-EBNA1 antibodies as well as their combinatorial value as biomarkers for MS. PMID:26831522

  16. Mortality in a complete 4-year follow up of 85-year-old residents of Leiden, classified by serum level of thyrotropin and thyroxine.

    PubMed

    Singer, Richard B

    2006-01-01

    The authors of the source article emphasize the clinical tendency to screen for, detect and treat for thyroid dysfunction in very elderly patients, in which it is a fairly common disorder, often with occult or no symptoms. Published evidence is conflicting on the benefit, if any, of such a program. Accordingly, they devised a prospective, population-based study to determine outcomes, including survival outcome, based on serum levels of thyroid-stimulating hormone (TSH) and thyroxine. A cohort of 558 subjects who had their 85th birthday between September 1997 and September 1999 was enrolled after consent of the subject and screening examination that included serum TSH and thyroxine levels. This represented a 79% sample of all 85-year-old residents of Leiden, the Netherlands. Follow up was complete for survival 4 years to the subject's 89th birthday or prior death, although 70 subjects refused the annual re-examination. Thyroid function, disability, cognitive function and number of chronic diseases were analyzed, in addition to mortality, through Cox regression and other statistical methods. In 67 subjects with abnormally high TSH (>4.8 mIU/ L), the mean annual mortality rate was derived as 64 deaths per 1000 per year. In the 491 subjects with normal TSH or low TSH (<0.3 mIU/L), the mean annual mortality rate was derived at 114 per 1000 per year. Laboratory evidence of hypothyroidism (initially low serum thyroxine) was found in only 37 of the 67 subjects. In the 13% of elderly subjects in Leiden with abnormally high serum TSH levels, the mean annual mortality rate was significantly lower than the mortality rate in the 87% of the elderly patients with normal or low serum TSH. The significance is based on 95% confidence levels of the Poisson distribution. The rate in the group with high TSH levels had 16 deaths in 264 person-years of follow up (FU). The majority with normal or low TSH levels had 193 deaths in 1698 person-years of FU.

  17. Thyroid function in neonatal hypothyroidism.

    PubMed

    Dussault, J H; Letarte, J; Guyda, H; Laberge, C

    1976-10-01

    Various aspects of the thyroid function have been measured in 28 cases of neonatal hypothyroidism detected by means of the Quebec Screening Program for Metabolic Diseases. In all instances the T4 value in the blood of filter paper spot was below 2 SD of the mean of the day, averaging 0.39 +/- 0.04 ng/40 mul (mean +/- SEM) of eluted blood. The T4 value of a second similar sample averaged 0.22 +/- 0.04 ng/mul of eluted blood; this value was significantly lower than the first one. The serum T4 concentration was decreased in all the infants, whereas three of them had a normal serum TSH concentration. At least three groups of patients could be identified: (1) patients with primary thyroid failure, (2) those with secondary or tertiary hypothyrodism, and (3) those with abnormal synthesis of thyroid hormone.

  18. Screening for celiac disease in patients with osteoporosis.

    PubMed

    Legroux-Gérot, Isabelle; Leloire, Olivier; Blanckaert, Franck; Tonnel, François; Grardel, Bruno; Ducrocq, Jean-Louis; Cortet, Bernard

    2009-03-01

    Whether patients with osteoporosis should be screened for celiac disease is controversial. The objective of this study was to measure the prevalence of asymptomatic celiac disease in a cohort of patients with osteoporosis. We studied 140 patients (133 postmenopausal women and 7 men) aged 40-75 years (mean age, 62.9+/-9.4 years) with primary osteoporosis diagnosed by absorptiometry (spine or hip T-score <-2.5SD). We routinely measured serum and urinary calcium, serum phosphate, alkaline phosphatase, 25-OH-vitamin D3, and IgG and IgA antigliadin antibodies. Patients with positive antigliadin antibody tests were tested for antitransglutaminase antibodies. A history of fractures were noted in 52 (37%) patients, with 57 peripheral and 54 vertebral fractures overall. Vitamin D deficiency was found in 60 (43%) patients. IgG antigliadin antibodies were positive in 11 (8%) patients, IgA antigliadin antibodies in 11 (8%) patients, and both antibodies in 4 (3%) patients. Antitransglutaminase antibodies were negative in all patients. No significant differences in laboratory test or absorptiometry results were found between patients with versus without IgA antigliadin antibodies. The T-score at the spine was nonsignificantly lower in patients with than without IgG antigliadin antibodies (-3.17+/-0.49 and -2.82+/-0.77, P=0.076). We found no excess risk of celiac disease in our cohort of patients with osteoporosis. Despite the small sample size, our results cast doubt on the need for celiac-disease screening in osteoporotic patients who have no gastrointestinal symptoms.

  19. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    PubMed

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  20. Field evaluation of two point-of-care tests for syphilis among men who have sex with men, Verona, Italy.

    PubMed

    Zorzi, Antonella; Cordioli, Maddalena; Gios, Lorenzo; Del Bravo, Paola; Toskin, Igor; Peeling, Rosanna W; Blondeel, Karel; Cornaglia, Giuseppe; Kiarie, James; Ballard, Ronald; Mirandola, Massimo

    2017-12-01

    The incidence of HIV and syphilis among men who have sex with men (MSM) in Europe has recently increased. Rapid point-of-care tests (POCTs) for syphilis can improve access to screening. The purpose of this study was to evaluate the performance of two syphilis POCTs compared with laboratory tests among MSM. The study was undertaken in Verona, Italy. Asymptomatic MSM, potentially exposed to syphilis, were enrolled prospectively. The POCTs evaluated were SD Bioline Syphilis 3.0 and Chembio DPP Syphilis Screen & Confirm Assay on both serum and fingerprick blood. The results of the POCTs were read by the naked eye by two independent readers and their concordance assessed. A total of 289 MSM were enrolled in the study. Based on laboratory tests, 35 MSM (12.1%) were TPPA-positive alone and 16 (5.5%) were both Treponema pallidum particle agglutination test (TPPA) and rapid plasma reagin (RPR)-positive. The specificities of both POCTs were above 99% on both serum and fingerstick blood specimens, while sensitivities varied considerably. The sensitivity of the SD Bioline test was lower on fingerprick blood (51.4% and 54.3%, readers 1 and 2, respectively) compared with that on serum (80.0% and 82.9%). In contrast, the Chembio test exhibited similar sensitivity values for serum and fingerprick samples (57.7% and 64.0% on serum vs 65.4% and 69.2% on fingerprick for the treponemal component; 63.6% on both samples by both readers for the non-treponemal component). The positive predictive value ranged between 100% and 93.9% for the treponemal component of both syphilis POCTs, but was lower (76.3%-100%)%) for the non-treponemal component of the Chembio POCT. The negative predictive value surpassed 90% for both tests on both samples. The agreement between readers was very high (>99%). The diagnostic performance of the syphilis POCTs was lower than expected; however, considering the prevalence of syphilis among MSM, POCTs should be recommended to improve syphilis detection among MSM. © World Health Organization [2017]. Licensee BMJ Publishing Group Limited. This is an open access article distributed under the terms of the Creative Commons Attribution IGO License (CC BY 4.0), which permits use, distribution, and reproduction for non-commercial purposes in any medium, provided the original work is properly cited. In any reproduction of this article there should not be any suggestion that WHO or this article endorse any specific organization or products. The use of the WHO logo is not permitted. This notice should be preserved along with the article’s original URL.

  1. Stomach (Gastric) Cancer Screening (PDQ®)—Health Professional Version

    Cancer.gov

    For stomach (gastric) cancer, there is no standard or routine screening test for the general U.S. population. Review the evidence on the benefits and harms of screening for gastric cancer using barium-meal photofluorography, gastric endoscopy, or serum pepsinogen in this expert-reviewed summary.

  2. Terbium-sensitized luminescence screening method for fluoroquinolones in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods commonly used for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay was developed...

  3. The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer.

    PubMed

    Dong, Xueyan; Wang, Guoqing; Zhang, Guoqing; Ni, Zhaohui; Suo, Jian; Cui, Juan; Cui, Ai; Yang, Qing; Xu, Ying; Li, Fan

    2013-03-19

    Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it's highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552.

  4. The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer

    PubMed Central

    2013-01-01

    Background Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. Methods The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. Result We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it’s highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). Conclusions The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552 PMID:23510199

  5. Experience of the Manitoba Perinatal Screening Program, 1965-85.

    PubMed Central

    Fox, J G

    1987-01-01

    The Manitoba Perinatal Screening Program is guided by a committee of medical specialists with skills in the diagnosis and management of disorders of metabolism in the newborn. The program is voluntary and is centralized at Cadham Provincial Laboratory, in Winnipeg. A filter card blood specimen is collected from newborns on discharge from hospital, and a filter card urine sample is collected and mailed to the laboratory by the mother when the infant is about 2 weeks of age. The overall compliance rates for the blood and urine specimens are approximately 100% and 84% respectively. The blood specimen is screened for phenylalanine and other amino acids, thyroxine, galactose, galactose-1-phosphate and biotinidase. The urine specimen is screened for amino acids, including cystine, as well as methylmalonic acid and homocystine. Between 1965 and 1985, 83 cases of metabolic disorders were detected, including 23 cases of primary hypothyroidism, 14 of classic phenylketonuria, 5 of galactosemia variants, 3 of galactosemia, 2 of maple syrup urine disease and 1 of hereditary tyrosinemia. The direct cost per infant screened is $5.50, and the cost:benefit ratio is approximately 7.5:1. Maternal serum alpha-fetoprotein screening is being made available as the necessary supporting clinical facilities become available. On the basis of this experience, the author outlines the components that are important for an effective screening program. PMID:3676929

  6. Second Trimester Maternal Serum Screening

    MedlinePlus

    ... Non-invasive Prenatal Screening (2016) Elsewhere On The Web National Down Syndrome Society Spina Bifida Association Trisomy ... request form. If your question relates to this web site and not to a specific lab test, ...

  7. 4th generation HIV screening in Massachusetts: a partnership between laboratory and program.

    PubMed

    Goodhue, Tammy; Kazianis, Arthur; Werner, Barbara G; Stiles, Tracy; Callis, Barry P; Dawn Fukuda, H; Cranston, Kevin

    2013-12-01

    The Massachusetts Department of Public Health's (MDPH) Office of HIV/AIDS (OHA) and Hinton State Laboratory Institute (HSLI) have offered HIV screening since 1985. Point-of-care screening and serum collection for laboratory-based testing is conducted at clinic and non-clinic-based sites across Massachusetts as part of an integrated communicable disease screening intervention. MDPH aimed to transition to a 4th generation HIV screening-based algorithm for testing all serum specimens collected at OHA-funded programs and submitted to the HSLI to detect acute HIV infections, detect and differentiate HIV-1 and HIV-2 infections, eliminate indeterminate results, reduce cost and turnaround time, and link newly diagnosed HIV+ individuals to care. The HSLI and OHA created a joint project management team to plan and lead the transition. The laboratory transitioned successfully to a 4th generation screening assay as part of a revised diagnostic algorithm. In the 12 months since implementation, a total of 7984 serum specimens were tested with 258 (3.2%) positive for HIV-1 and one positive for HIV-2. Eight were reported as acute HIV-1 infections. These individuals were linked to medical care and partner services in a timely manner. Turnaround time was reduced and the laboratory realized an overall cost savings of approximately 15%. The identification of eight acute HIV infections in the first year underscores the importance of using the most sensitive screening tests available. A multi-disciplinary program and laboratory team was critical to the success of the transition, and the lessons learned may be useful for other jurisdictions. Published by Elsevier B.V.

  8. Analysis of the discriminative methods for diagnosis of benign and malignant solitary pulmonary nodules based on serum markers.

    PubMed

    Wang, Wanping; Liu, Mingyue; Wang, Jing; Tian, Rui; Dong, Junqiang; Liu, Qi; Zhao, Xianping; Wang, Yuanfang

    2014-01-01

    Screening indexes of tumor serum markers for benign and malignant solitary pulmonary nodules (SPNs) were analyzed to find the optimum method for diagnosis. Enzyme-linked immunosorbent assays, an automatic immune analyzer and radioimmunoassay methods were used to examine the levels of 8 serum markers in 164 SPN patients, and the sensitivity for differential diagnosis of malignant or benign SPN was compared for detection using a single plasma marker or a combination of markers. The results for serological indicators that closely relate to benign and malignant SPNs were screened using the Fisher discriminant analysis and a non-conditional logistic regression analysis method, respectively. The results were then verified by the k-means clustering analysis method. The sensitivity when using a combination of serum markers to detect SPN was higher than that using a single marker. By Fisher discriminant analysis, cytokeratin 19 fragments (CYFRA21-1), carbohydrate antigen 125 (CA125), squamous cell carcinoma antigen (SCC) and breast cancer antigen (CA153), which relate to the benign and malignant SPNs, were screened. Through non-conditional logistic regression analysis, CYFRA21-1, SCC and CA153 were obtained. Using the k-means clustering analysis, the cophenetic correlation coefficient (0.940) obtained by the Fisher discriminant analysis was higher than that obtained with logistic regression analysis (0.875). This study indicated that the Fisher discriminant analysis functioned better in screening out serum markers to recognize the benign and malignant SPN. The combined detection of CYFRA21-1, CA125, SCC and CA153 is an effective way to distinguish benign and malignant SPN, and will find an important clinical application in the early diagnosis of SPN. © 2014 S. Karger GmbH, Freiburg.

  9. Trans-Cutaneous Bilirubinometery versus Serum Bilirubin in Neonatal Jaundice.

    PubMed

    Mahram, Manoochehr; Oveisi, Sonia; Jaberi, Najmeh

    2015-12-01

    Hyperbilirubinemia is a common problem in neonates and causes serious complications. Thus, serial measurements of bilirubin should be done. This assessment is done through two methods of laboratory measurement in serum sample and transcutaneous bilirubinometer. This descriptive study compared transcutaneous bilirubin assessment and laboratory serum bilirubin. Bilirubin level was assessed among 256 neonates admitted to the Qods Children's Hospital in Qazvin- Iran, because of neonatal indirect jaundice, through two methods of transcutaneous bilirubinometery from two sites of forehead and sternum and laboratory measurement of bilirubin in serum. The cases were non-hemolytic icteric term neonates weighing 2500 gram or more and had not received phototherapy or other treatments. Neonates with hemolytic forms of jaundice, sepsis and suspicious to metabolic disorders were excluded. Assessments by means of KJ-8000 transcutaneous bilirubinometer from two sites of forehead and sternum and through laboratory measurement of serum bilirubin were registered and analyzed. The results of the current study showed that there was a correlation of 0.82 between serum bilirubin and transcutaneous forehead bilirubin assessment and for the used device sensitivity of 0.844; specificity of 0.842, Youden Index of 0.709 and Shortest of 0.042 for a cut-off of 12.4 in bilirubin of participants. Furthermore, Likelihood Ratio positive and negative (LR) were 5.665 and 0.164, respectively and diagnostic Odds Ratio (LR+/LR-) was 34.56. Transcutaneous bilirubinometery can be considered as a reliable tool to assess bilirubin for the screening of neonatal jaundice in term neonates.

  10. New serum biomarkers for detection of tuberculosis using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Liu, Ji-Yan; Jin, Lei; Zhao, Meng-Yuan; Zhang, Xin; Liu, Chi-Bo; Zhang, Yu-Xiang; Li, Fu-Jian; Zhou, Jian-Min; Wang, Hua-Jun; Li, Ji-Cheng

    2011-10-01

    New technologies for the early detection of tuberculosis (TB) are urgently needed. Pathological changes within an organ might be reflected in proteomic patterns in serum. The aim of the present study was to screen for the potential protein biomarkers in serum for the diagnosis of TB using proteomic fingerprint technology. Proteomic fingerprint technology combining protein chips with surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) was used to profile the serum proteins from 50 patients with TB, 25 patients with lung disease other than TB, and 25 healthy volunteers. The protein fingerprint expression of all the serum samples and the resulting profiles between TB and control groups were analyzed with the Biomarker Wizard system. A total of 30 discriminating m/z peaks were detected that were related to TB (p<0.01). The model of biomarkers constructed by the Biomarker Patterns Software based on the three biomarkers (2024, 8007, and 8598 Da) generated excellent separation between the TB and control groups. The sensitivity was 84.0% and the specificity was 86.0%. Blind test data indicated a sensitivity of 80.0% and a specificity of 84.2%. The data suggested a potential application of SELDI-TOF MS as an effective technology to profile serum proteome, and with pattern analysis, a diagnostic model comprising three potential biomarkers was indicated to differentiate people with TB and healthy controls rapidly and precisely.

  11. Correlations between serum trypsinogen-2 and pancreatic cancer.

    PubMed

    Cao, Jianbiao; Xia, Changhong; Cui, Tingting; Guo, Hanbin; Li, Haoran; Ren, Yongqiang; Wang, Shuai

    2015-01-01

    To investigate associations be- tween serum trypsinogen-2, pancreatitis and pancreatic cancer (PC) and determine cutoff values for PC diagnosis. We recruited 88 patients from Internal Medicine/Surgical Departments of General Military Hospital of Beijing PLA between 12/2009 and 6/2010. Serum samples were collected preoperatively from 23 PC patients, 30 pancreatitis patients and 35 healthy controls. Enzyme-linked immunosorbent assay was used to detect trypsinogen-2 semiquantitatively. Serum trypsinogen-2 levels of PC and pancreatitis patients were significantly higher than those of controls (51.2 ± 80.3, 107.7 ± 98.1 vs. 1.0 ± 0.5, p = 0.03, p < 0.001) and significantly higher in pancreatitis vs. PC patients (107.7 ± 98.1 vs. 51.2 ± 80.3, p = 0.01). Higher Balthazar CT grades correlated with higher trypsinogen-2 in pancreatitis group. ROC curves for trypsinogen-2 revealed optimal cutoff value 1.8 as lower PC detection limit with 95.7% sensitivity and 91.4% specificity, and optimal cutoff value 19.9 for upper PC detection limit with 87.0% sensitivity and 97.1% specificity. Trypsinogen-2 levels correlated with pancreatic injury level. An AUC of 0.73 (95% Cl: 0.59-0.84, p = 0.002) distinguished PC from pancreatitis. Serum trypsinogen-2 is associated with PC and pancreatitis. Levels between 1.8 μg/L and 19.9 μg/L strongly suggest PC. Detection of serum trypsinogen-2 may provide simple, sensitive, specific non-invasive initial screening for early PC diagnosis.

  12. Comparisons of serum miRNA expression profiles in patients with diabetic retinopathy and type 2 diabetes mellitus.

    PubMed

    Ma, Jianping; Wang, Jufang; Liu, Yanfen; Wang, Changyi; Duan, Donghui; Lu, Nanjia; Wang, Kaiyue; Zhang, Lu; Gu, Kaibo; Chen, Sihan; Zhang, Tao; You, Dingyun; Han, Liyuan

    2017-02-01

    The aim of this study was to compare the expression levels of serum miRNAs in diabetic retinopathy and type 2 diabetes mellitus. Serum miRNA expression profiles from diabetic retinopathy cases (type 2 diabetes mellitus patients with diabetic retinopathy) and type 2 diabetes mellitus controls (type 2 diabetes mellitus patients without diabetic retinopathy) were examined by miRNA-specific microarray analysis. Quantitative real-time polymerase chain reaction was used to validate the significantly differentially expressed serum miRNAs from the microarray analysis of 45 diabetic retinopathy cases and 45 age-, sex-, body mass index- and duration-of-diabetes-matched type 2 diabetes mellitus controls. The relative changes in serum miRNA expression levels were analyzed using the 2-ΔΔCt method. A total of 5 diabetic retinopathy cases and 5 type 2 diabetes mellitus controls were included in the miRNA-specific microarray analysis. The serum levels of miR-3939 and miR-1910-3p differed significantly between the two groups in the screening stage; however, quantitative real-time polymerase chain reaction did not reveal significant differences in miRNA expression for 45 diabetic retinopathy cases and their matched type 2 diabetes mellitus controls. Our findings indicate that miR-3939 and miR-1910-3p may not play important roles in the development of diabetic retinopathy; however, studies with a larger sample size are needed to confirm our findings.

  13. Time-resolved luminescence screening method for enrofloxacin in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods currently used in the U.S. for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay ...

  14. Innovative approaches to vitamin A assessment.

    PubMed

    Craft, N E

    2001-05-01

    The health and sight of millions of children are compromised each year as a consequence of vitamin A (VA) deficiency. Serum retinol is the most commonly used indicator of VA status. Unfortunately, its use is impractical for national surveys because it involves collection of venous blood, centrifugation and frozen storage before analysis. To make VA assessment more practical, we have developed approaches incorporating dried blood spots (DBS) or portable instrumentation. DBS have been used as a sample matrix to screen neonates for many biochemical compounds. Until recently, it was not thought that VA was stable in DBS. However, we demonstrated that the measure of DBS retinol correlates well with serum retinol in both healthy adults (r(2) = 0.88-0.90) and compromised populations (r(2) = 0.73-0.84). Compared with serum retinol, the sensitivity and specificity of detecting VA deficiency by DBS retinol range from 73 to 93% and from 90 to 100%, respectively. Although few data are available, retinol binding protein (RBP) can also be measured in DBS. RBP has been used as a surrogate marker for serum retinol. Correlations coefficients (r(2)) between serum RBP and serum retinol range from 0.4 to 0.8. In addition, work has been done to develop portable instrumentation to measure VA status in the field. A fluorometer has been optimized for VA fluorescence and is linear into the deficient range for the direct fluorimetric measurement of serum holo-RBP. Progress is being made to use the instrument to directly measure holo-RBP in a drop of whole blood.

  15. A prospective study of serum soluble CD30 concentration and risk of non-Hodgkin lymphoma

    PubMed Central

    Lan, Qing; Martinez-Maza, Otoniel; Oken, Martin M.; Hocking, William; Huang, Wen-Yi; Baris, Dalsu; Conde, Betty; Rothman, Nathaniel

    2009-01-01

    Prediagnostic serum concentration of soluble CD30 (sCD30), a marker for chronic B-cell stimulation, has been associated with increased risk of developing AIDS-related non-Hodgkin lymphoma (NHL) in a recent study of HIV+ patients. To investigate among healthy persons whether serum sCD30 is associated with NHL risk, we carried out a nested case-control study within the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial. There was a strong dose-response relationship between prediagnostic sCD30 concentration and NHL risk among 234 cases and 234 individually matched controls (odds ratio [95% confidence interval] for second, third, and fourth quartiles vs first quartile: 1.4 [0.8-2.6], 2.2 [1.2-4.1], 4.1 [2.2-7.8]; Ptrend < .001), which persisted among cases diagnosed 6 to 10 years after providing a blood sample. Given that a similar relationship has been observed among HIV+ patients, our findings suggest that chronic B-cell stimulation may be an important mechanism involved in B-cell lymphomagenesis among severely immunocompromised and healthy populations alike. PMID:19638620

  16. Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Shin, Yongho; Lee, Jonghwa; Lee, Jiho; Lee, Junghak; Kim, Eunhye; Liu, Kwang-Hyeon; Lee, Hye Suk; Kim, Jeong-Han

    2018-04-04

    A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were ≥0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 μL) was extracted with acetonitrile (400 μL), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further cleanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation ≤20%).

  17. Multiplex analysis of pro-inflammatory cytokines in serum of Actinobacillus pleuropneumoniae-infected pigs.

    PubMed

    Wyns, H; Croubels, S; Vandekerckhove, M; Demeyere, K; De Backer, P; Goddeeris, B M; Meyer, E

    2015-10-01

    Porcine pleuropneumonia is a severe respiratory disease caused by Actinobacillus (A.) pleuropneumoniae. The aim of the present study was to analyze serum samples of A. pleuropneumoniae-infected pigs for TNF-α, IL-1β and IL-6 using a cytometric bead array (CBA) 3-plex assay and additionally for IL-6 using ELISA. The CBA 3-plex assay was successfully validated for use in serum. The limits of detection varied between 0.012 and 0.333 ng/mL, and the inter- and inter-assay coefficients of variation were <5% and <10%, respectively. Increased levels were observed for all 3 cytokines following experimental infection with A. pleuropneumoniae. Mean peak concentrations of TNF-α and IL-6 were recorded at 12h and at 10h p.i., respectively. For IL-6, similar concentration-time profiles were observed with CBA and ELISA. It is proposed that this immuno-assay can be applied for the screening of immunomodulatory properties of drugs and vaccine adjuvants in infection, inflammation and vaccination. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Anti-hypercholesterolemic effect of kenaf (Hibiscus cannabinus L.) seed on high-fat diet Sprague dawley rats.

    PubMed

    Kai, Ng Shy; Nee, Tee Ai; Ling, Elaine Lai Chia; Ping, Tan Chin; Kamariah, Long; Lin, Nyam Kar

    2015-01-01

    To determine the antihypercholesterolemic effects of kenaf seed samples and compare with the commercial hypocholesterolemic drug on serum lipids profiles and malondialdehyde (MDA) level in the rat. Kenaf seed oil (KSO), microencapsulated kenaf seed oil (MKSO), kenaf seed extract (KSE) and defatted kenaf seed meal (DKSM) were prepared and phytochemicals screening on these samples were done prior in vivo study. Phenolic compounds in KSE were quantified using high performance liquid chromatography. There were 40 (divided in eight diet groups of 5) male Sprague dawley rats adapted to normal standard diet or hypercholesterolemic diet (HD) with or without the treatment of these kenaf samples for 32 days. All the kenaf samples exhibited to contain most of the major phytochemicals. KSE possessed gallic acid, tannic acid, catechin, benzaldehyde, benzoic acid, syringic acid, sinapic acid, ferulic acid, naringin acid, and protocatechuic acid. The significant higher (P<0.05) serum total cholesterol, low density lipoprotein cholesterol and MDA levels in HD group without treatment than the normal control group suggested the hypercholesterolemia was induced by the incorporation of cholesterol into diet. KSE exhibited higher cholesterol-lowering properties due to the significant lower (P<0.05) in serum triglycerides, total cholesterol and MDA levels. KSE showed the highest efficiency of cholesterol-lowering activity, followed by KSO, MKSO and DKSM. DKSM, MKSO, KSO and KSE appeared to have comparable anti-hypercholesterolemic effect with the commercial hypocholesterolemic drug. Hence, kenaf seed could be used as an alternative natural source to replace the synthetic hypocholesterolemic drugs. Copyright © 2015 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.

  19. Decreased expression of glutathione S-transferase pi correlates with poorly differentiated grade in patients with oral squamous cell carcinoma.

    PubMed

    Ma, Hai-long; Yu, Cong; Liu, Ying; Tan, Yi-ran; Qiao, Jin-ke; Yang, Xi; Wang, Li-zhen; Li, Jiang; Chen, Qiong; Chen, Fu-xiang; Zhang, Zhi-yuan; Zhong, Lai-ping

    2015-03-01

    Glutathione S transferase pi (GSTP1) is a member of phase II detoxification enzymes as a major regulator of cell signaling in response to stress, hypoxia, growth factors, and other stimuli. The clinical role of GSTP1 in cancer is still unclear. The aim of this study was to investigate the serum GSTP1 level in patients with oral squamous cell carcinoma (OSCC) and the GSTP1 expression in tissue samples from patients with OSCC and OSCC lines. One hundred and sixty-six patients with OSCC and 120 normal persons were used to screen potential serum peptide biomarkers using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Serum GSTP1 concentration was detected in 18 patients with OSCC and 18 normal persons using ELISA. Immunohistochemistry was used to detect GSTP1 expression in tissue samples from twenty-eight OSCC patients. Western blot and real-time PCR were used to detect GSTP1 expression in nine OSCC lines. Decreased GSTP1 concentration was found in the patients with OSCC compared with the normal persons by MALDI-TOF-MS, which was then confirmed by ELISA (P = 0.019). Decreased GSTP1 mRNA level and protein expression were also found in the OSCC lines. Decreased GSTP1 expression was found correlating with pathological differentiation grade in the tissue samples from OSCC patients, a lower GSTP1 expression indicating a poorer pathological differentiation grade (P = 0.041). These results suggest that decreased GSTP1 expression in patients with OSCC and a lower GSTP1 expression indicating a poorer pathological differentiation grade in OSCC tissue samples. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Computational diagnosis of canine lymphoma

    NASA Astrophysics Data System (ADS)

    Mirkes, E. M.; Alexandrakis, I.; Slater, K.; Tuli, R.; Gorban, A. N.

    2014-03-01

    One out of four dogs will develop cancer in their lifetime and 20% of those will be lymphoma cases. PetScreen developed a lymphoma blood test using serum samples collected from several veterinary practices. The samples were fractionated and analysed by mass spectrometry. Two protein peaks, with the highest diagnostic power, were selected and further identified as acute phase proteins, C-Reactive Protein and Haptoglobin. Data mining methods were then applied to the collected data for the development of an online computer-assisted veterinary diagnostic tool. The generated software can be used as a diagnostic, monitoring and screening tool. Initially, the diagnosis of lymphoma was formulated as a classification problem and then later refined as a lymphoma risk estimation. Three methods, decision trees, kNN and probability density evaluation, were used for classification and risk estimation and several preprocessing approaches were implemented to create the diagnostic system. For the differential diagnosis the best solution gave a sensitivity and specificity of 83.5% and 77%, respectively (using three input features, CRP, Haptoglobin and standard clinical symptom). For the screening task, the decision tree method provided the best result, with sensitivity and specificity of 81.4% and >99%, respectively (using the same input features). Furthermore, the development and application of new techniques for the generation of risk maps allowed their user-friendly visualization.

  1. Exposure of Asian Elephants and Other Exotic Ungulates to Schmallenberg Virus.

    PubMed

    Molenaar, Fieke M; La Rocca, S Anna; Khatri, Meenakshi; Lopez, Javier; Steinbach, Falko; Dastjerdi, Akbar

    2015-01-01

    Schmallenberg virus (SBV) is an emerging Orthobunyavirus, first described in 2011 in cattle in Germany and subsequently spread throughout Europe, affecting mainly ruminant livestock through the induction of foetal malformations. To gain a better understanding of the spectrum of susceptible species and to assess the value of current SBV serological assays, screening of serum samples from exotic artiodactyls and perissodactyls collected at the Living Collections from the Zoological Society of London (Whipsnade and London Zoos) and Chester Zoo was carried out. There was compelling evidence of SBV infection in both zoological collections. The competitive ELISA has proved to be applicable for the detection of SBV in exotic Bovidae, Cervidae, Suidae, Giraffidae and most notably in endangered Asian elephants (Elephas maximus), but unreliable for the screening of Camelidae, for which the plaque reduction neutralisation test was considered the assay of choice.

  2. Gastric Cancer Screening by Combined Determination of Serum Helicobacter pylori Antibody and Pepsinogen Concentrations: ABC Method for Gastric Cancer Screening.

    PubMed

    Chen, Xian-Zhe; Huang, Cheng-Zhi; Hu, Wei-Xian; Liu, Ying; Yao, Xue-Qing

    2018-05-20

    Gastroscopy combined with gastric mucosa biopsies is currently regarded as a gold standard for diagnosis of gastric cancer. However, its application is restricted in clinical practice due to its invasive property. A new noninvasive population screening process combining the assay of anti-Helicobacter pylori antibody and serum pepsinogen (PG) (ABC method) is adopted to recognize the high-risk patients for further endoscopy examination, avoiding the unnecessary gastroscopy for most population and saving the cost consumption for mass screening annually. Nevertheless, controversies exist for the grouping of ABC method and the intervals of gastroscopy surveillance for each group. In this review, we summarized these popular concerned topics for providing useful references to the healthcare practitioner in clinical practice. The PubMed databases were systematically searched from the inception dates to November 22, 2017, using the keywords "Helicobacter pylori," "Pepsinogens," and "Stomach Neoplasms." Original articles and reviews on the topics were selected. Anti-H. pylori antibody and serum PG concentration showed significant changes under the different status of H. pylori infection and the progression of atrophic gastritis, which can be used for risk stratification of gastric cancer in clinic. In addition, anti-H. pylori antibody titer can be used for further risk stratification of gastric cancer contributing to determine better endoscopy surveillance interval. The early detection and diagnosis of gastric cancer benefit from the risk stratification, but the cutoff values for H. pylori antibody and serum PG concentration require further modification.

  3. A Sandwich ELISA for Adducts of Polycyclic Aromatic Hydrocarbons with Human Serum Albumin1

    PubMed Central

    Chung, Ming Kei; Riby, Jacques; Li, He; Iavarone, Anthony T.; Williams, Evan R.; Zheng, Yuxin; Rappaport, Stephen M.

    2010-01-01

    Adducts of benzo[α]pyrene-diolepoxide (BPDE)2 with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive ELISA which employs monoclonal antibody 8E11 to detect benzo[α]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we use 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1 mg samples of HSA or 20 μL of serum/plasma. The assay employs an anti-HSA antibody for detection, which is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is about 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high (coke-oven workers), medium (steel-factory control workers), and low (volunteer subjects) PAH exposures (n = 30). The respective geometric mean levels of BPDE-HSA adducts, i.e., 67.8, 14.7 and 1.93 ng/mg HSA (1,010, 220 and 28.9 fmol BPDE equivalents/mg HSA), were significantly different (p < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available. PMID:20083082

  4. Toxoplasma Serotype Is Associated With Development of Ocular Toxoplasmosis

    PubMed Central

    Shobab, Leila; Pleyer, Uwe; Johnsen, Joerdis; Metzner, Sylvia; James, Erick R.; Torun, N.; Fay, Michael P.; Liesenfeld, Oliver; Grigg, Michael E.

    2013-01-01

    Background. Worldwide, ocular toxoplasmosis (OT) is the principal cause of posterior uveitis, a severe, life-altering disease. A Toxoplasma gondii enzyme-linked immunoassay that detects strain-specific antibodies present in serum was used to correlate serotype with disease. Methods. Toxoplasma serotypes in consecutive serum samples from German uveitis patients with OT were compared with non-OT seropositive patients with noninfectious autoimmune posterior uveitis. OT patients were tested for association of parasite serotype with age, gender, location, clinical onset, size, visual acuity, or number of lesions (mean follow-up, 3.8 years) to determine association with recurrences. Results. A novel, nonreactive (NR) serotype was detected more frequently in serum samples of OT patients (50/114, 44%) than in non-OT patients (4/56, 7%) (odds ratio, 10.0; 95% confidence interval 3.4–40.8; P < .0001). Non-OT patients were predominantly infected with Type II strains (39/56; 70%), consistent with expected frequencies in Central Europe. Among OT patients, those with NR serotypes experienced more frequent recurrences (P = .037). Polymerase chain reaction detected parasite DNA in 8/60 OT aqueous humor specimens but failed to identify Type II strain alleles. Conclusions. Toxoplasma NR and Type II serotypes predominate in German OT patients. The NR serotype is associated with OT recurrences, underscoring the value of screening for management of disease. PMID:23878321

  5. Association between BDNF levels and suicidal behaviour: a systematic review and meta-analysis.

    PubMed

    Eisen, Rebecca B; Perera, Stefan; Banfield, Laura; Anglin, Rebecca; Minuzzi, Luciano; Samaan, Zainab

    2015-12-30

    Suicidal behaviour is a complex phenomenon with a multitude of risk factors. Brain-derived neurotrophic factor (BDNF), a protein crucial to nervous system function, may be involved in suicide risk. The objective of this systematic review is to evaluate and summarize the literature examining the relationship between BDNF levels and suicidal behaviour. A predefined search strategy was used to search MEDLINE, EMBASE, PsychINFO, and CINAHL from inception to December 2015. Studies were included if they investigated the association between BDNF levels and suicidal behaviours (including completed suicide, attempted suicide, or suicidal ideation) by comparing BDNF levels in groups with and without suicidal behaviour. Only the following observational studies were included: case-control and cohort studies. Both clinical- and community-based samples were included. Screening, data extraction, and risk of bias assessment were conducted in duplicate. Six-hundred thirty-one articles were screened, and 14 were included in the review. Three studies that assessed serum BDNF levels in individuals with suicide attempts and controls were combined in a meta-analysis that showed no significant association between serum BDNF and suicide attempts. The remaining 11 studies were not eligible for the meta-analysis and provided inconsistent findings regarding associations between BDNF and suicidal behaviour. The findings of the meta-analysis indicate that there is no significant association between serum BDNF and attempted suicide. The qualitative review of the literature did not provide consistent support for an association between BDNF levels and suicidal behaviour. The evidence has significant methodological limitations. PROSPERO CRD42015015871.

  6. Molecular diagnosis of Toxoplasma gondii infection in Libya.

    PubMed

    Gashout, Aisha; Amro, Ahmad; Erhuma, Mabruk; Al-Dwibe, Hamida; Elmaihub, Eanas; Babba, Hamouda; Nattah, Nabil; Abudher, Abdalhafid

    2016-04-16

    Toxoplasma gondii infections are prevalent in humans and animals throughout Libya. Current diagnosis is based on detection of Toxoplasma-specific IgM and IgG. In this study, we established and optimized a diagnostic PCR assay for molecular diagnosis of T. gondii in Libya. From January to December, 2010, 177 blood and serum samples were collected from suspected patients. This includes: 140 women who have had spontaneous abortions, 26 HIV-positive patients, nine patients with leukemia and lymphoma, and two infants with ocular infection. Samples were screened for anti-Toxoplasma IgG and IgM antibodies before DNA extraction. The surface antigen gene 2 (SAG2) was targeted in a semi-nested PCR to amplify a 999 bp and a 614 bp fragment in the first and the second run respectively. A total of 54/140 (38.5 %) women who have had spontaneous abortions, 23/26 (88 %) HIV patients, 6/9 (66.6 %) of the leukaemia and lymphoma patients, and one child with ocular infection were seropositive for anti-Toxoplasma IgG and/or IgM. Genomic DNA was extracted from 38 selected seropositive samples. The PCR was sensitive enough to detect DNA concentration of 12 ng/μL. PCR analysis was performed for 38 selected seropositive patients (16 women who have had spontaneous abortions, 15 positive HIV patients, six leukaemia patients and one child with ocular infection). Our designed primers were successfully amplified in 22/38 (57.9 %) samples; 5/12 (35.7 %) from serum and 17/26 (65.8 %) from whole blood samples. All PCR positive samples were IgG-positive except two samples which were IgM and IgG & IgM-positive serum samples respectively. The semi-nested PCR confirmed five more samples. These included two leukaemia and two HIV-positive whole blood samples and one serum sample from an aborted woman. The ability of PCR to diagnose active toxoplasmosis is needed in immunocompromised patients and congenital toxoplasmosis cases, especially when serological techniques fail. For the first time in Libya, we established and optimized semi-nested PCR of SAG2 gene. The developed PCR method was able to detect as little as 12 ng/μL of T. gondii DNA and was useful to diagnose the diseases in women who have had spontaneous abortions, HIV-positive patients, patients with leukemia and lymphoma, and infants with ocular infection.

  7. Rapid screening and identification of dominant B cell epitopes of HBV surface antigen by quantum dot-based fluorescence polarization assay

    NASA Astrophysics Data System (ADS)

    Meng, Zhongji; Song, Ruihua; Chen, Yue; Zhu, Yang; Tian, Yanhui; Li, Ding; Cui, Daxiang

    2013-03-01

    A method for quickly screening and identifying dominant B cell epitopes was developed using hepatitis B virus (HBV) surface antigen as a target. Eleven amino acid fragments from HBV surface antigen were synthesized by 9-fluorenylmethoxy carbonyl solid-phase peptide synthesis strategy, and then CdTe quantum dots were used to label the N-terminals of all peptides. After optimizing the factors for fluorescence polarization (FP) immunoassay, the antigenicities of synthetic peptides were determined by analyzing the recognition and combination of peptides and standard antibody samples. The results of FP assays confirmed that 10 of 11 synthetic peptides have distinct antigenicities. In order to screen dominant antigenic peptides, the FP assays were carried out to investigate the antibodies against the 10 synthetic peptides of HBV surface antigen respectively in 159 samples of anti-HBV surface antigen-positive antiserum. The results showed that 3 of the 10 antigenic peptides may be immunodominant because the antibodies against them existed more widely among the samples and their antibody titers were higher than those of other peptides. Using three dominant antigenic peptides, 293 serum samples were detected for HBV infection by FP assays; the results showed that the antibody-positive ratio was 51.9% and the sensitivity and specificity were 84.3% and 98.2%, respectively. In conclusion, a quantum dot-based FP assay is a very simple, rapid, and convenient method for determining immunodominant antigenic peptides and has great potential in applications such as epitope mapping, vaccine designing, or clinical disease diagnosis in the future.

  8. Opc expression, LPS immunotype switch and pilin conversion contribute to serum resistance of unencapsulated meningococci.

    PubMed

    Hubert, Kerstin; Pawlik, Marie-Christin; Claus, Heike; Jarva, Hanna; Meri, Seppo; Vogel, Ulrich

    2012-01-01

    Neisseria meningitidis employs polysaccharides and outer membrane proteins to cope with human serum complement attack. To screen for factors influencing serum resistance, an assay was developed based on a colorimetric serum bactericidal assay. The screening used a genetically modified sequence type (ST)-41/44 clonal complex (cc) strain lacking LPS sialylation, polysaccharide capsule, the factor H binding protein (fHbp) and MutS, a protein of the DNA repair mechanism. After killing of >99.9% of the bacterial cells by serum treatment, the colorimetric assay was used to screen 1000 colonies, of which 35 showed enhanced serum resistance. Three mutant classes were identified. In the first class of mutants, enhanced expression of Opc was identified. Opc expression was associated with vitronectin binding and reduced membrane attack complex deposition confirming recent observations. Lipopolysaccharide (LPS) immunotype switch from immunotype L3 to L8/L1 by lgtA and lgtC phase variation represented the second class. Isogenic mutant analysis demonstrated that in ST-41/44 cc strains the L8/L1 immunotype was more serum resistant than the L3 immunotype. Consecutive analysis revealed that the immunotypes L8 and L1 were frequently observed in ST-41/44 cc isolates from both carriage and disease. Immunotype switch to L8/L1 is therefore suggested to contribute to the adaptive capacity of this meningococcal lineage. The third mutant class displayed a pilE allelic exchange associated with enhanced autoaggregation. The mutation of the C terminal hypervariable region D of PilE included a residue previously associated with increased pilus bundle formation. We suggest that autoaggregation reduced the surface area accessible to serum complement and protected from killing. The study highlights the ability of meningococci to adapt to environmental stress by phase variation and intrachromosomal recombination affecting subcapsular antigens.

  9. Opc Expression, LPS Immunotype Switch and Pilin Conversion Contribute to Serum Resistance of Unencapsulated Meningococci

    PubMed Central

    Hubert, Kerstin; Pawlik, Marie-Christin; Claus, Heike; Jarva, Hanna; Meri, Seppo; Vogel, Ulrich

    2012-01-01

    Neisseria meningitidis employs polysaccharides and outer membrane proteins to cope with human serum complement attack. To screen for factors influencing serum resistance, an assay was developed based on a colorimetric serum bactericidal assay. The screening used a genetically modified sequence type (ST)-41/44 clonal complex (cc) strain lacking LPS sialylation, polysaccharide capsule, the factor H binding protein (fHbp) and MutS, a protein of the DNA repair mechanism. After killing of >99.9% of the bacterial cells by serum treatment, the colorimetric assay was used to screen 1000 colonies, of which 35 showed enhanced serum resistance. Three mutant classes were identified. In the first class of mutants, enhanced expression of Opc was identified. Opc expression was associated with vitronectin binding and reduced membrane attack complex deposition confirming recent observations. Lipopolysaccharide (LPS) immunotype switch from immunotype L3 to L8/L1 by lgtA and lgtC phase variation represented the second class. Isogenic mutant analysis demonstrated that in ST-41/44 cc strains the L8/L1 immunotype was more serum resistant than the L3 immunotype. Consecutive analysis revealed that the immunotypes L8 and L1 were frequently observed in ST-41/44 cc isolates from both carriage and disease. Immunotype switch to L8/L1 is therefore suggested to contribute to the adaptive capacity of this meningococcal lineage. The third mutant class displayed a pilE allelic exchange associated with enhanced autoaggregation. The mutation of the C terminal hypervariable region D of PilE included a residue previously associated with increased pilus bundle formation. We suggest that autoaggregation reduced the surface area accessible to serum complement and protected from killing. The study highlights the ability of meningococci to adapt to environmental stress by phase variation and intrachromosomal recombination affecting subcapsular antigens. PMID:23028802

  10. Serum ALT levels as a surrogate marker for serum HBV DNA levels in HBeAg-negative pregnant women.

    PubMed

    Sangfelt, Per; Von Sydow, Madeleine; Uhnoo, Ingrid; Weiland, Ola; Lindh, Gudrun; Fischler, Björn; Lindgren, Susanne; Reichard, Olle

    2004-01-01

    In Stockholm, Sweden, the majority of pregnant women positive for hepatitis B surface antigen (HBsAg) are hepatitis Be antigen (HBeAg) negative. Newborns to HBeAg positive mothers receive vaccination and hepatitis B immunoglobulin (HBIg). Newborns to HBeAg negative mothers receive vaccine and HBIg only if the mothers have elevated ALT levels. The aim of this study was to retrospectively evaluate ALT levels as a surrogate marker for HBV DNA levels in HBeAg negative carrier mothers. Altogether 8947 pregnant women were screened for HBV markers from 1999 to 2001 at the Virology Department, Karolinska Hospital. Among mothers screened 192 tested positive for HBsAg (2.2%). 13 of these samples could not be retrieved. Of the remaining 179 sera, 8 (4%) tested positive for HBeAg and 171 (95.5%) were HBeAg negative. Among the HBeAg negative mothers, 9 had HBV DNA levels > 10(5) copies/ml, and of these 7 had normal ALT levels indicating low sensitivity of an elevated ALT level as a surrogate marker for high HBV DNA level. Furthermore, no correlation was found between ALT and HBV DNA levels. Hence, it is concluded that the use of ALT as a surrogate marker for high viral replication in HBeAg negative mothers could be questioned.

  11. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    PubMed

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  12. Immunodiagnosis of Echinococcus Infections: Confirmatory Testing and Species Differentiation by a New Commercial Western Blot

    PubMed Central

    Liance, Martine; Janin, Veronique; Bresson-Hadni, Solange; Vuitton, Dominique-Angele; Houin, Rene; Piarroux, Renaud

    2000-01-01

    The Echinococcus Western Blot IgG (LDBIO Diagnostics, Lyon, France), using a whole larval antigen from Echinococcus multilocularis, was evaluated for serodiagnosis and differentiation between two human parasitic infections of worldwide importance: cystic echinococcosis, due to Echinococcus granulosus, and alveolar echinococcosis, due to E. multilocularis. Fifty and 61 serum samples from patients with cystic and alveolar echinococcosis, respectively, were used for assessing diagnostic sensitivity. The sensitivity of the assay was compared with those of screening tests used for these applications. Sera used for assessing cross-reactivities were from 154 patients with other diseases, either parasitic or not. The assay allowed the detection of serum immunoglobulin G antibodies in 97% of Echinococcus-infected patients. It had a higher sensitivity than screening assays for the detection for each echinococcosis. The assay allowed us to correctly distinguish between E. granulosus- and E. multilocularis-infected patients in 76% of cases. It did not allow us to distinguish active from inactive forms of both echinococcoses. The occurrence of cross-reactivities with neurocysticercosis indicates the necessity for retesting sera with species-specific antigens, for rare patients with neurologic disorders. This study shows the usefulness of the commercially available Echinococcus Western Blot IgG for the serological confirmation of human echinococcosis. PMID:11015390

  13. Proxy indicators for identifying iron deficiency among anemic vegetarians in an area prevalent for thalassemia and hemoglobinopathies.

    PubMed

    Wongprachum, Kasama; Sanchaisuriya, Kanokwan; Sanchaisuriya, Pattara; Siridamrongvattana, Sirivara; Manpeun, Suwanna; Schlep, Frank P

    2012-01-01

    The study aimed to determine the proportion of iron deficiency (ID) anemia (IDA) among vegans in northeast Thailand and to explore whether mathematical formulas derived from red blood cell (RBC) indices are applicable for IDA screening in the study population. Blood samples from 234 individuals (age 6-45 years) living in a vegan community were taken. Complete blood cell count, serum ferritin, hemoglobin profiles and DNA analysis for α-thalassemia were determined. Anemia was defined using the WHO criteria adjusted for age and sex. Serum ferritin <15 ng/ml was considered as ID. A number of mathematical formulas derived from RBC indices were applied to screen ID among anemic individuals. Anemia was found in 41.5% (95% CI = 35.1-48.1%) of the study participants. The overall proportion of thalassemia and hemoglobinopathies was 56.4% (95% CI = 49.8-62.9%). Of the anemic participants, 45.4% had ID. Based on the receiver-operating characteristic curve analysis, 4 formulas were applicable for predicting ID among anemic individuals (highest sensitivity of 86.4%). The proposed formulas might be used as proxy indicators for the identification of ID among anemic children and adult vegans if more sophisticated laboratory determinations are not available due to limited financial resources. Copyright © 2012 S. Karger AG, Basel.

  14. A multi-analyte profile of serum proteins to screen for toxicological effects of anticholinesterase insecticides in the rat

    EPA Science Inventory

    The development of high throughput biochemical screens could be useful to assess the broad spectrum of physiological effects of environmental toxicants. To explore the prospect of using a screen in an in vivo exposure scenario, we applied a commercially available multianalyte pro...

  15. Effect of a Hypocretin/Orexin Antagonist on Neurocognitive Performance

    DTIC Science & Technology

    2011-09-01

    physical exam, urine drug and pregnancy screen, and blood draw for hematology and serum chemistry panels. Eligible Participants: 21 participants have...20 5.5 Drug Storage and Accountability...amphetamines, cocaine, cannabis, or any other illicit drugs within 30 days of screening by self report or a urine toxicology screen; 20.) Known

  16. Development of an enrichment method for endogenous phosphopeptide characterization in human serum.

    PubMed

    La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Ferraris, Francesca; Laus, Michele; Piovesana, Susy; Sparnacci, Katia; Laganà, Aldo

    2018-01-01

    The work describes the development of an enrichment method for the analysis of endogenous phosphopeptides in serum. Endogenous peptides can play significant biological roles, and some of them could be exploited as future biomarkers. In this context, blood is one of the most useful biofluids for screening, but a systematic investigation of the endogenous peptides, especially phosphorylated ones, is still lacking, mainly due to the lack of suitable analytical methods. Thus, in this paper, different phosphopeptide enrichment strategies were pursued, based either on metal oxide affinity chromatography (MOAC, in the form of commercial TiO 2 spin columns or magnetic graphitized carbon black-TiO 2 composite), or on immobilized metal ion affinity chromatography (IMAC, in the form of Ti 4+ -IMAC magnetic material or commercial Fe 3+ -IMAC spin columns). While MOAC strategies proved completely unsuccessful, probably due to interfering phospholipids displacing phosphopeptides, the IMAC materials performed very well. Different sample preparation strategies were tested, comprising direct dilution with the loading buffer, organic solvent precipitation, and lipid removal from the matrix, as well as the addition of phosphatase inhibitors during sample handling for maximized endogenous phosphopeptide enrichment. All data were acquired by a shotgun peptidomics approach, in which peptide samples were separated by reversed-phase nanoHPLC hyphenated with high-resolution tandem mass spectrometry. The devised method allowed the identification of 176 endogenous phosphopeptides in fresh serum added with inhibitors by the direct dilution protocol and the Ti 4+ -IMAC magnetic material enrichment, but good results could also be obtained from the commercial Fe 3+ -IMAC spin column adapted to the batch enrichment protocol.

  17. Label-free serum ribonucleic acid analysis for colorectal cancer detection by surface-enhanced Raman spectroscopy and multivariate analysis

    NASA Astrophysics Data System (ADS)

    Chen, Yanping; Chen, Gang; Feng, Shangyuan; Pan, Jianji; Zheng, Xiongwei; Su, Ying; Chen, Yan; Huang, Zufang; Lin, Xiaoqian; Lan, Fenghua; Chen, Rong; Zeng, Haishan

    2012-06-01

    Studies with circulating ribonucleic acid (RNA) not only provide new targets for cancer detection, but also open up the possibility of noninvasive gene expression profiling for cancer. In this paper, we developed a surface-enhanced Raman scattering (SERS), platform for detection and differentiation of serum RNAs of colorectal cancer. A novel three-dimensional (3-D), Ag nanofilm formed by dry MgSO4 aggregated silver nanoparticles, Ag NP, as the SERS-active substrate was presented to effectively enhance the RNA Raman signals. SERS measurements were performed on two groups of serum RNA samples. One group from patients, n=55 with pathologically diagnosed colorectal cancer and the other group from healthy controls, n=45. Tentative assignments of the Raman bands in the normalized SERS spectra demonstrated that there are differential expressions of cancer-related RNAs between the two groups. Linear discriminate analysis, based on principal component analysis, generated features can differentiate the colorectal cancer SERS spectra from normal SERS spectra with sensitivity of 89.1 percent and specificity of 95.6 percent. This exploratory study demonstrated great potential for developing serum RNA SERS analysis into a useful clinical tool for label-free, noninvasive screening and detection of colorectal cancers.

  18. Prevalence of Brucella spp in humans.

    PubMed

    Soares, Catharina de Paula Oliveira Cavalcanti; Teles, José Andreey Almeida; dos Santos, Aldenir Feitosa; Silva, Stemberg Oliveira Firmino; Cruz, Maria Vilma Rocha Andrade; da Silva-Júnior, Francisco Feliciano

    2015-01-01

    to determine the seroprevalence of Brucella spp in humans. this is an observational study, developed with 455 individuals between 18 and 64 years old, who use the Estratégia de Saúde da Família (Brazil's family health strategy). The serum samples of volunteers underwent buffered acid antigen tests, such as screening, agar gel immunodiffusion and slow seroagglutination test in tubes and 2-Mercaptoethanol. among the samples, 1.98% has responded to buffered-acid antigen, 2.85% to agar gel immunodiffusion test and 1.54% to the slow seroagglutination tests on tubes/2-Mercaptoethanol. The prevalence of Brucella spp was 4.4%, represented by the last two tests. the results of this research suggest that the studied population is exposed to Brucella spp infection.

  19. [Design and evaluation of DAVIH VIH-2].

    PubMed

    Martín Alfonso, Dayamí; Silva Cabrera, Eladio; Pérez Guevara, María T; Díaz Herrera, Dervel F; Romero Martínez, Kenia; Díaz Torres, Héctor M; Lubián Caballero, Ana L; Ruiz Gutiérrez, Nancy; Ortiz Losada, Eva

    2007-01-01

    The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100% sensitivity, 99,81% specificity, 99,81% efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba.

  20. Effect of a new marker, ADAM12, on Down risk figures in first trimester screening.

    PubMed

    Valinen, Yrtti; Laitinen, Paivi; Ranta, Jenni; Ignatius, Jaakko; Jarvela, Ilkka; Ryynänen, Markku

    2009-07-01

    To investigate whether incorporating the measurement of ADAM12 in the risk calculation program LifeCycle, can improve Down screening in the first trimester. In a retrospective case control study, maternal serum ADAM12 concentrations were measured and compared in Down syndrome cases (n = 53) and in controls (n = 226) obtained from first trimester (9-12 weeks) screening samples in Oulu and Kuopio University Hospitals. Median concentration ( microg/l), observed and regressed (weight corrected) MoMs of ADAM12 were calculated. There was a significant difference in ADAM12 levels between Downs and controls during the pregnancy weeks 9 + 0 to 10 + 6, but not thereafter. By adding ADAM12 to the marker set used in the risk calculation program, one screening false negative Down syndrome case occurred in the affected population, which did not alter false positive rate. Adding ADAM12 as a parameter in Down screening did not cause radical changes in the risk value. The test might be useful at 9 and 10 weeks in which it might have the potential to improve the performance of the risk assessment especially for women receiving a result close to the high-risk cut-off. The real influence of ADAM12 remains to be elucidated in larger studies incorporating ADAM12 to the risk calculation program.

  1. An Overview on Prenatal Screening for Chromosomal Aberrations.

    PubMed

    Hixson, Lucas; Goel, Srishti; Schuber, Paul; Faltas, Vanessa; Lee, Jessica; Narayakkadan, Anjali; Leung, Ho; Osborne, Jim

    2015-10-01

    This article is a review of current and emerging methods used for prenatal detection of chromosomal aneuploidies. Chromosomal anomalies in the developing fetus can occur in any pregnancy and lead to death prior to or shortly after birth or to costly lifelong disabilities. Early detection of fetal chromosomal aneuploidies, an atypical number of certain chromosomes, can help parents evaluate their pregnancy options. Current diagnostic methods include maternal serum sampling or nuchal translucency testing, which are minimally invasive diagnostics, but lack sensitivity and specificity. The gold standard, karyotyping, requires amniocentesis or chorionic villus sampling, which are highly invasive and can cause abortions. In addition, many of these methods have long turnaround times, which can cause anxiety in mothers. Next-generation sequencing of fetal DNA in maternal blood enables minimally invasive, sensitive, and reasonably rapid analysis of fetal chromosomal anomalies and can be of clinical utility to parents. This review covers traditional methods and next-generation sequencing techniques for diagnosing aneuploidies in terms of clinical utility, technological characteristics, and market potential. © 2015 Society for Laboratory Automation and Screening.

  2. Digital sensing and sizing of vesicular stomatitis virus pseudotypes in complex media: a model for Ebola and Marburg detection.

    PubMed

    Daaboul, George G; Lopez, Carlos A; Chinnala, Jyothsna; Goldberg, Bennett B; Connor, John H; Ünlü, M Selim

    2014-06-24

    Rapid, sensitive, and direct label-free capture and characterization of nanoparticles from complex media such as blood or serum will broadly impact medicine and the life sciences. We demonstrate identification of virus particles in complex samples for replication-competent wild-type vesicular stomatitis virus (VSV), defective VSV, and Ebola- and Marburg-pseudotyped VSV with high sensitivity and specificity. Size discrimination of the imaged nanoparticles (virions) allows differentiation between modified viruses having different genome lengths and facilitates a reduction in the counting of nonspecifically bound particles to achieve a limit-of-detection (LOD) of 5 × 10(3) pfu/mL for the Ebola and Marburg VSV pseudotypes. We demonstrate the simultaneous detection of multiple viruses in a single sample (composed of serum or whole blood) for screening applications and uncompromised detection capabilities in samples contaminated with high levels of bacteria. By employing affinity-based capture, size discrimination, and a "digital" detection scheme to count single virus particles, we show that a robust and sensitive virus/nanoparticle sensing assay can be established for targets in complex samples. The nanoparticle microscopy system is termed the Single Particle Interferometric Reflectance Imaging Sensor (SP-IRIS) and is capable of high-throughput and rapid sizing of large numbers of biological nanoparticles on an antibody microarray for research and diagnostic applications.

  3. Interference in diagnostic tests for brucellosis in cattle recently vaccinated against leptospirosis.

    PubMed

    Naves, Joao Helder Frederico de Faria; Rezende, Lais M; Ramos, Gabriel C; Soares, Pollyanna M; Tavares, Tatiane C F; França, Andre M S; Neves, Saira M N; Silva, Natascha A M; Lima-Ribeiro, Anna M C

    2012-03-01

    The aim of the current study was to verify if cattle vaccinated against leptospirosis may react in diagnostic tests for brucellosis. Sixty cows were divided into 5 groups, each comprising 12 animals. Four groups were given different vaccines against leptospirosis, while the control group received only saline. Two doses of vaccine were given, as recommended by the manufacturers. Serum samples were collected on the first day of immunization (day 0) and on postvaccination days 7, 14, 21, 28, 35, 42, 49, 56, 96, and 126. All the serum samples were tested for brucellosis and leptospirosis. Twenty animals were reactive at least once to the Rose Bengal test, but by day 96, no further reactions were elicited by this test. Twenty-six samples were reactive to the Rose Bengal test, but only 7 remained positive in confirmatory tests: 1 to the 2-mercaptoethanol test, 2 to the fluorescence polarization assay, and 6 to indirect enzyme-linked immunosorbent assays. None of the samples was reactive in the complement fixation test. None of the animals in the control group was reactive. A significant difference was found between the control group and the groups vaccinated against leptospirosis, according to Fisher exact test. However, the groups were found to respond independently of the vaccine brand. The results indicate that cattle vaccinated against leptospirosis may show reactivity on screening tests for brucellosis.

  4. Autoantibody targets in vaccine-associated narcolepsy.

    PubMed

    Häggmark-Månberg, Anna; Zandian, Arash; Forsström, Björn; Khademi, Mohsen; Lima Bomfim, Izaura; Hellström, Cecilia; Arnheim-Dahlström, Lisen; Hallböök, Tove; Darin, Niklas; Lundberg, Ingrid E; Uhlén, Mathias; Partinen, Markku; Schwenk, Jochen M; Olsson, Tomas; Nilsson, Peter

    2016-09-01

    Narcolepsy is a chronic sleep disorder with a yet unknown cause, but the specific loss of hypocretin-producing neurons together with a strong human leukocyte antigen (HLA) association has led to the hypothesis that autoimmune mechanisms might be involved. Here, we describe an extensive effort to profile autoimmunity repertoires in serum with the aim to find disease-related autoantigens. Initially, 57 serum samples from vaccine-associated and sporadic narcolepsy patients and controls were screened for IgG reactivity towards 10 846 fragments of human proteins using planar microarrays. The discovered differential reactivities were verified on suspension bead arrays in the same sample collection followed by further investigation of 14 antigens in 176 independent samples, including 57 narcolepsy patients. Among these 14 antigens, methyltransferase-like 22 (METTL22) and 5'-nucleotidase cytosolic IA (NT5C1A) were recognized at a higher frequency in narcolepsy patients of both sample sets. Upon sequence analysis of the 14 proteins, polymerase family, member 3 (PARP3), acyl-CoA-binding domain containing 7 (ARID4B), glutaminase 2 (GLS2) and cyclin-dependent kinase-like 1 (CDKL1) were found to contain amino acid sequences with homology to proteins found in the H1N1 vaccine. These findings could become useful elements of further clinical assays that aim towards a better phenotypic understanding of narcolepsy and its triggers.

  5. Developments in Screening Tests and Strategies for Colorectal Cancer

    PubMed Central

    Sovich, Justin L.; Sartor, Zachary

    2015-01-01

    Background. Worldwide, colorectal cancer (CRC) is the third most common cancer in men and second most common in women. It is the fourth most common cause of cancer mortality. In the United States, CRC is the third most common cause of cancer and second most common cause of cancer mortality. Incidence and mortality rates have steadily fallen, primarily due to widespread screening. Methods. We conducted keyword searches on PubMed in four categories of CRC screening: stool, endoscopic, radiologic, and serum, as well as news searches in Medscape and Google News. Results. Colonoscopy is the gold standard for CRC screening and the most common method in the United States. Technological improvements continue to be made, including the promising “third-eye retroscope.” Fecal occult blood remains widely used, particularly outside the United States. The first at-home screen, a fecal DNA screen, has also recently been approved. Radiological methods are effective but seldom used due to cost and other factors. Serum tests are largely experimental, although at least one is moving closer to market. Conclusions. Colonoscopy is likely to remain the most popular screening modality for the immediate future, although its shortcomings will continue to spur innovation in a variety of modalities. PMID:26504799

  6. Reverse Fluorescence Enhancement and Colorimetric Bimodal Signal Readout Immunochromatography Test Strip for Ultrasensitive Large-Scale Screening and Postoperative Monitoring.

    PubMed

    Yao, Yingyi; Guo, Weisheng; Zhang, Jian; Wu, Yudong; Fu, Weihua; Liu, Tingting; Wu, Xiaoli; Wang, Hanjie; Gong, Xiaoqun; Liang, Xing-Jie; Chang, Jin

    2016-09-07

    Ultrasensitive and quantitative fast screening of cancer biomarkers by immunochromatography test strip (ICTS) is still challenging in clinic. The gold nanoparticles (NPs) based ICTS with colorimetric readout enables a quick spectrum screening but suffers from nonquantitative performance; although ICTS with fluorescence readout (FICTS) allows quantitative detection, its sensitivity still deserves more efforts and attentions. In this work, by taking advantages of colorimetric ICTS and FICTS, we described a reverse fluorescence enhancement ICTS (rFICTS) with bimodal signal readout for ultrasensitive and quantitative fast screening of carcinoembryonic antigen (CEA). In the presence of target, gold NPs aggregation in T line induced colorimetric readout, allowing on-the-spot spectrum screening in 10 min by naked eye. Meanwhile, the reverse fluorescence enhancement signal enabled more accurately quantitative detection with better sensitivity (5.89 pg/mL for CEA), which is more than 2 orders of magnitude lower than that of the conventional FICTS. The accuracy and stability of the rFICTS were investigated with more than 100 clinical serum samples for large-scale screening. Furthermore, this rFICTS also realized postoperative monitoring by detecting CEA in a patient with colon cancer and comparing with CT imaging diagnosis. These results indicated this rFICTS is particularly suitable for point-of-care (POC) diagnostics in both resource-rich and resource-limited settings.

  7. Screening for hemochromatosis by measuring ferritin levels: a more effective approach

    PubMed Central

    Waalen, Jill; Felitti, Vincent J.; Gelbart, Terri

    2008-01-01

    Because the penetrance of HFE hemochromatosis is low, traditional population screening measuring the transferrin saturation is unlikely to be cost-effective because the majority of subjects detected neither have clinical disease nor are likely to develop it. Three independent studies show that only patients with serum ferritin concentrations more than 1000 μg/L are at risk for cirrhosis, one of the main morbidities of hemochromatosis. Among 29 699 white subjects participating in the Scripps/Kaiser hemochromatosis study, only 59 had serum ferritin levels more than 1000 μg/L; 24 had homozygous mutant or compound heterozygous mutant HFE genotypes. In all but 5 of the other subjects, the causes of elevated ferritin were excessive alcohol intake, cancer, or liver disease. Screening for hemochromatosis with serum ferritin levels will detect the majority of patients who will be clinically affected and may detect other clinically significant disease in patients who do not have hemochromatosis genotypes. Because the ferritin level of the majority of adult homozygotes for HFE mutations does not rise over long periods of time, excluding subjects with serum ferritin levels less than or equal to 1000 μg/L should not result in missed opportunities for early treatment of patients who could benefit. PMID:18025154

  8. Anxiety levels in women undergoing prenatal maternal serum screening for Down syndrome: the effect of a fast reporting system by mobile phone short-message service.

    PubMed

    Cheng, Po-Jen; Wu, Tzong-Lin; Shaw, Sheng-Wen; Chueh, Ho-Yen; Lin, Cheng-Tao; Hsu, Jenn-Jeih; Hsieh, T'sang-T'ang; Soong, Yung-Kuei

    2008-05-01

    To study the effect of fast reporting by mobile phone short-message service (SMS) on anxiety levels in women undergoing prenatal biochemical screening for Down syndrome. From January 2005 to December 2006, 2782 women undergoing prenatal biochemical serum screening were randomized into fast reporting by SMS (group A) or without mobile phone reporting (group B). Anxiety levels were measured with the Spielberger State-Trait Anxiety Inventory (STAI) before prenatal screen testing, before the appointed clinic (when the SMS report had already been given to group A), and 3 days after the appointed clinic (when the full screening report had been given to groups A and B). For screen-negative women, anxiety scores did not differ between groups before prenatal screen testing and 3 days after the appointed clinic. The state-anxiety scores measured on the second occasion had declined significantly in group A. The state-anxiety scores in both groups increased over the 3-week period after being informed of positive screen results. The trait- and state-anxiety scores at all points did not differ between the two groups of screen-positive women. The provision of a routine reporting system plus additional SMS report revealed some overall benefits in reducing anxiety among women with screen-negative result. 2008 John Wiley & Sons, Ltd

  9. Hemochromatosis and Iron Overload Screening (HEIRS) study design for an evaluation of 100,000 primary care-based adults.

    PubMed

    McLaren, Christine E; Barton, James C; Adams, Paul C; Harris, Emily L; Acton, Ronald T; Press, Nancy; Reboussin, David M; McLaren, Gordon D; Sholinsky, Phyliss; Walker, Ann P; Gordeuk, Victor R; Leiendecker-Foster, Catherine; Dawkins, Fitzroy W; Eckfeldt, John H; Mellen, Beverly G; Speechley, Mark; Thomson, Elizabeth

    2003-02-01

    The HEIRS Study will evaluate the prevalence, genetic and environmental determinants, and potential clinical, personal, and societal impact of hemochromatosis and iron overload in a multiethnic, primary care-based sample of 100,000 adults over a 5-year period. Participants are recruited from 5 Field Centers. Laboratory testing and data management and analysis are performed in a Central Laboratory and Coordinating Center, respectively. Participants undergo testing for serum iron measures and common mutations of the hemochromatosis gene ( ) on chromosome 6p and answer questions on demographics, health, and genetic testing attitudes. Participants with elevated values of transferrin saturation and serum ferritin and/or C282Y homozygosity are invited to undergo a comprehensive clinical examination (CCE), as are frequency-matched control subjects. These examinations provide data on personal and family medical history, lifestyle characteristics, physical examination, genetic counseling, and assessment of ethical, legal, and social implications. Primary and secondary causes of iron overload will be distinguished by clinical criteria. Iron overload will be confirmed by quantification of iron stores. Recruiting family members of cases will permit DNA analysis for additional genetic factors that affect iron overload. Of the first 50,520 screened, 51% are white, 24% are African American, 11% are Asian, 11% are Hispanic, and 3% are of other, mixed, or unidentified race; 63% are female and 37% are male. Information from the HEIRS Study will inform policy regarding the feasibility, optimal approach, and potential individual and public health benefits and risks of primary care-based screening for iron overload and hemochromatosis.

  10. Amniotic fluid and maternal serum levels of CA125 in pregnancies affected by Down syndrome: a re-evaluation of the role of CA125 in Down syndrome screening.

    PubMed

    Spencer, K; Muller, F; Aitken, D A

    1997-08-01

    In a study of amniotic fluid from 91 Down syndrome cases and 240 controls, we have shown that the median value of CA125 in pregnancies affected by Down syndrome on the whole reflects those observed in the maternal serum from 106 affected cases and 238 controls. The median MOM for CA125 in amniotic fluid from Down syndrome pregnancies was 1.04 and in maternal serum 1.06, neither value being significantly different from that for the control population. We confirm our previous observation that CA125 is not a marker of Down syndrome and conclude that CA125 has no role to play in Down syndrome screening.

  11. Health Screening: What Tests You Need and When

    MedlinePlus

    ... cancer screening if you are considering having a prostate-specific antigen (PSA) test or digital rectal examination (DRE). Sexually ... regular colonoscopy for cancer of the colon, serum prostatic-specific antigen (PSA) for prostate cancer, mammography for breast cancer, ...

  12. Overnight dexamethasone suppression test: a reliable screen for Cushing's syndrome in the obese.

    PubMed

    Ness-Abramof, Rosane; Nabriski, Dan; Apovian, Caroline M; Niven, Mark; Weiss, Eliahu; Shapiro, Menachem S; Shenkman, Louis

    2002-12-01

    Reevaluation of the validity of the 1-mg overnight dexamethasone suppression test (ODST) as a screening test for Cushing's syndrome in obese patients. Eighty-six obese patients (body mass index, 30 to 53 kg/m(2)) that were referred to a general endocrine outpatient clinic for evaluation of simple obesity, diabetes mellitus, hypertension, polycystic ovary disease, or pituitary tumor. One milligram dexamethasone was administered orally at 11:00 PM, and serum cortisol levels were measured the following morning between 8:00 AM and 9:00 AM. Suppression of serum cortisol to <80 nM (3 micro g/dL) was chosen as the cut-off point for normal suppression. Patients with serum cortisol levels > or =80 nM were evaluated for Cushing's syndrome. Suppression of morning cortisol levels to <80 nM occurred in 79 of the 86 obese patients. Seven patients had serum cortisol levels higher than 80 nM; five were eventually diagnosed with Cushing's syndrome and two were considered false positive results in view of normal 24-hour free urinary cortisol and normal suppression on a low dose dexamethasone suppression test (0.5 mg of dexamethasone every 6 hours for 2 days). We found a false positive rate of 2.3% for the ODST using a cut-off serum cortisol of 80 nM. The ODST is a valid screening test for Cushing's syndrome in the obese population. The false positive rate was 2.3%, even when using a strict cut-off serum cortisol of 80 nM. Abnormal cortisol suppression in obese patients should be investigated and not be considered false positive results.

  13. Do we need to measure total serum IgA to exclude IgA deficiency in coeliac disease?

    PubMed Central

    Sinclair, D; Saas, M; Turk, A; Goble, M; Kerr, D

    2006-01-01

    Background Screening for IgA deficiency in patients with coeliac disease is essential because of the increased incidence of IgA deficiency associated with the disease, which usually relies on the estimation of IgA levels in each case. Aim To devise a method of excluding IgA deficiency without measuring total serum IgA in each case. Materials and methods The optical density readings on enzyme‐linked immunosorbent assay (ELISA) of 608 routine samples received for tissue transglutaminase (TTG) antibody testing for coeliac disease were compared with their total IgA concentrations. Dilution experiments were also carried out to ensure linear relationships between optical density on ELISA and IgA concentrations and to compare the sensitivities for TTG and endomysium antibodies in TTG‐positive samples. Results and discussion A clear relationship was shown between total IgA concentration and TTG optical density readings by ELISA. To ensure a positive TTG result if antibodies are present, it was possible to recommend an optical density level above which all samples have sufficient IgA. Samples with optical density <0.05 should be investigated further by estimating total IgA and, if low, samples should be subjected to immunofluorescence microscopy testing for IgA and IgG endomysium antibodies. Conclusions An easier, more cost‐effective and practical way of excluding IgA deficiency in the investigation on coeliac disease is reported. PMID:16489174

  14. Diagnostic performance of a seven-marker serum protein biosignature for the diagnosis of active TB disease in African primary healthcare clinic attendees with signs and symptoms suggestive of TB.

    PubMed

    Chegou, Novel N; Sutherland, Jayne S; Malherbe, Stephanus; Crampin, Amelia C; Corstjens, Paul L A M; Geluk, Annemieke; Mayanja-Kizza, Harriet; Loxton, Andre G; van der Spuy, Gian; Stanley, Kim; Kotzé, Leigh A; van der Vyver, Marieta; Rosenkrands, Ida; Kidd, Martin; van Helden, Paul D; Dockrell, Hazel M; Ottenhoff, Tom H M; Kaufmann, Stefan H E; Walzl, Gerhard

    2016-09-01

    User-friendly, rapid, inexpensive yet accurate TB diagnostic tools are urgently needed at points of care in resource-limited settings. We investigated host biomarkers detected in serum samples obtained from adults with signs and symptoms suggestive of TB at primary healthcare clinics in five African countries (Malawi, Namibia, South Africa, The Gambia and Uganda), for the diagnosis of TB disease. We prospectively enrolled individuals presenting with symptoms warranting investigation for pulmonary TB, prior to assessment for TB disease. We evaluated 22 host protein biomarkers in stored serum samples using a multiplex cytokine platform. Using a pre-established diagnostic algorithm comprising of laboratory, clinical and radiological findings, participants were classified as either definite TB, probable TB, questionable TB status or non-pulmonary TB. Of the 716 participants enrolled, 185 were definite and 29 were probable TB cases, 6 had questionable TB disease status, whereas 487 had no evidence of TB. A seven-marker biosignature of C reactive protein, transthyretin, IFN-γ, complement factor H, apolipoprotein-A1, inducible protein 10 and serum amyloid A identified on a training sample set (n=491), diagnosed TB disease in the test set (n=210) with sensitivity of 93.8% (95% CI 84.0% to 98.0%), specificity of 73.3% (95% CI 65.2% to 80.1%), and positive and negative predictive values of 60.6% (95% CI 50.3% to 70.1%) and 96.4% (95% CI 90.5% to 98.8%), respectively, regardless of HIV infection status or study site. We have identified a seven-marker host serum protein biosignature for the diagnosis of TB disease irrespective of HIV infection status or ethnicity in Africa. These results hold promise for the development of a field-friendly point-of-care screening test for pulmonary TB. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Enzyme immunoassay of Chlamydia in birds.

    PubMed

    Ruppanner, R; Behymer, D E; DeLong, W J; Franti, C E; Schulz, T

    1984-01-01

    Serum samples from 192 free-living birds (27 species) were tested for antibodies against Chlamydia using the enzyme-linked immunosorbent assay (ELISA); 97 (51%) were seropositive. The highest antibody prevalence was among pheasants (96%), ducks (88%), and blackbirds (86%). None of 41 starlings tested were seropositive. The serotesting of 42 confined pheasants indicated 100% exposure to the organism. The ELISA is a sensitive, rapid serologic method that can be of epidemiologic and diagnostic value for detecting exposure to Chlamydia. The ELISA could also be used for mass-screening of pet birds where chlamydiosis may be considered a potential public health hazard.

  16. Preclinical screening for retinopathy of prematurity risk using IGF1 levels at 3 weeks post-partum.

    PubMed

    Pérez-Muñuzuri, Alejandro; Couce-Pico, Maria Luz; Baña-Souto, Ana; López-Suárez, Olalla; Iglesias-Deus, Alicia; Blanco-Teijeiro, José; Fernández-Lorenzo, José Ramón; Fraga-Bermúdez, José María

    2014-01-01

    Following current recommendations for preventing retinopathy of prematurity (ROP) involves screening a large number of patients. We performed a prospective study to establish a useful screening system for ROP prediction and we have determined that measuring serum levels of IGF1 at week three and the presence of sepsis have a high predictive value for the subsequent development of ROP. A total of 145 premature newborn, with birthweight <1500 g and/or <32 weeks gestational age, were enrolled. 26.9% of them showed some form of retinopathy. A significant association was found between the development of retinopathy and each of the following variables: early gestational age, low birthweight, requiring mechanical ventilation, oxygen treatment, intracranial haemorrhage, sepsis during the first three weeks, bronchopulmonary dysplasia, the need for erythrocyte transfusion, erythropoietin treatment, and low levels of serum IGF1 in the third week. A multiple logistic regression analysis was used to obtain curves for the probability of developing ROP, based on the main factors linked with ROP, namely serum levels of IGF1 and presence of sepsis. Such preclinical screening has the ability to identify patients with high-risk of developing retinopathy and should lead to better prediction for ROP, while at the same time optimising the use of clinical resources, both human and material.

  17. The role of circulating microRNA-126 (miR-126): a novel biomarker for screening prediabetes and newly diagnosed type 2 diabetes mellitus.

    PubMed

    Liu, Yang; Gao, Guangqiang; Yang, Chun; Zhou, Kun; Shen, Baozhong; Liang, Hongyan; Jiang, Xiaofeng

    2014-06-12

    Recent studies suggested an association of endothelial microRNA-126 (miR-126) with type 2 diabetes mellitus (T2DM). In the current study, we examined whether circulating miR-126 is associated with T2DM and pre-diabetic syndrome. The study included 82 subjects with impaired glucose tolerance (IGT), 75 subjects with impaired fasting glucose (IFG), 160 patients with newly diagnosed T2DM, and 138 healthy individuals. Quantitative polymerase chain reaction (qPCR) was used to examine serum miR-126. Serum miR-126 was significantly lower in IGT/IFG subjects and T2DM patients than in healthy controls (p<0.05). After six months of treatment (diet control and exercise in IGT/IFG subjects, insulin plus diet control and exercise in T2DM patients), serum miR-126 increased significantly (p<0.05). An analysis based on serum miR-126 in the sample revealed a significantly higher odds ratio (OR) for the subjects with the lowest 1/3 of serum miR-126 for T2DM (OR: 3.500, 95% confidence interval: 1.901-6.445, p<0.05) than subjects within the highest 1/3 of serum miR-126. Such an association was still apparent after adjusting for other major risk factors. The area under the curve (AUC) for the receiver-operating characteristic (ROC) analysis was 0.792 (95% confidence interval: 0.707-0.877, p<0.001). These results encourage the use of serum miR-126 as a biomarker for pre-diabetes and diabetes mellitus, as well as therapeutic response.

  18. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    PubMed Central

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM, Artacho-Cordón F, Barriuso-Lapresa L, Tusquets I, Dierssen-Sotos T, Aragonés N, Olea N, Kogevinas M, Pollán M. 2016. Total effective xenoestrogen burden in serum samples and risk for breast cancer in a population-based multicase–control study in Spain. Environ Health Perspect 124:1575–1582; http://dx.doi.org/10.1289/EHP157 PMID:27203080

  19. Screening of post-mortem tissue donors for Coxiella burnetii infection after large outbreaks of Q fever in The Netherlands

    PubMed Central

    2014-01-01

    Background After the largest outbreaks of Q fever ever recorded in history occurred in the Netherlands, concern arose that Coxiella may be transmitted via donated tissues of latent or chronically infected donors. The Dutch Health Council recently advised to screen tissue donors, donating high risk tissues, for Coxiella infection. Methods After validation of an enzyme immunoassay (EIA) test for IgG antibodies against phase 2 of C. burnetii for use on post-mortem samples, serum samples of 1033 consecutive Dutch post-mortem tissue donors were tested for IgG antibodies against phase 2 of C. burnetii. Confirmation of reactive results was done by immunofluorescence assay (IFA). All available tissues (corneas, heart valves, skin and bone marrow) from donors with IgG reactivity were tested for presence of Coxiella DNA by PCR. Risk factors for IgG reactivity were investigated. Results After validation of the tests for use on post-mortem samples, 50/1033 donors (4.8%) screened positive for phase 2 anti-Coxiella IgG by EIA, and 31 were confirmed by IFA (3.0%). One donor showed a serological profile compatible with chronic infection. All tested tissues (25 corneas, 6 heart valves, 4 skin and 3 bone marrow) from donors with IgG reactivity tested negative for the presence of Coxiella DNA. Except for living in a postal code area with a high number of Q fever notifications, no risk factors for IgG reactivity were found. Conclusions The strong correlation between notifications and seroprevalence confirms that the used assays are sufficiently specific for use on post-mortem samples, although one has to be aware of differences between batches. Thus, this study provides a validated method for screening tissue donors for infection with Coxiella burnetii that can be used in future outbreaks. PMID:24393298

  20. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

    PubMed

    Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A

    2006-06-01

    To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.

  1. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

    PubMed

    Wang, Linchuan; Chen, Wei; Yu, Yan

    2017-01-01

    To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.

  2. A comparison of serum and plasma cytokine values using a multiplexed assay in cats.

    PubMed

    Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X

    2016-12-01

    Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Prenatal screening for fetal aneuploidy in singleton pregnancies.

    PubMed

    Chitayat, David; Langlois, Sylvie; Douglas Wilson, R

    2011-07-01

    To develop a Canadian consensus document on maternal screening for fetal aneuploidy (e.g., Down syndrome and trisomy 18) in singleton pregnancies. Pregnancy screening for fetal aneuploidy started in the mid 1960s, using maternal age as the screening test. New developments in maternal serum and ultrasound screening have made it possible to offer all pregnant patients a non-invasive screening test to assess their risk of having a fetus with aneuploidy to determine whether invasive prenatal diagnostic testing is necessary. This document reviews the options available for non-invasive screening and makes recommendations for Canadian patients and health care workers. To offer non-invasive screening for fetal aneuploidy (trisomy 13, 18, 21) to all pregnant women. Invasive prenatal diagnosis would be offered to women who screen above a set risk cut-off level on non-invasive screening or to pregnant women whose personal, obstetrical, or family history places them at increased risk. Currently available non-invasive screening options include maternal age combined with one of the following: (1) first trimester screening (nuchal translucency, maternal age, and maternal serum biochemical markers), (2) second trimester serum screening (maternal age and maternal serum biochemical markers), or (3) 2-step integrated screening, which includes first and second trimester serum screening with or without nuchal translucency (integrated prenatal screen, serum integrated prenatal screening, contingent, and sequential). These options are reviewed, and recommendations are made. Studies published between 1982 and 2009 were retrieved through searches of PubMed or Medline and CINAHL and the Cochrane Library, using appropriate controlled vocabulary and key words (aneuploidy, Down syndrome, trisomy, prenatal screening, genetic health risk, genetic health surveillance, prenatal diagnosis). Results were restricted to systematic reviews, randomized controlled trials, and relevant observational studies. There were no language restrictions. Searches were updated on a regular basis and incorporated in the guideline to August 2010. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The previous Society of Obstetricians and Gynaecologists of Canada guidelines regarding prenatal screening were also reviewed in developing this clinical practice guideline. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care. This guideline is intended to reduce the number of prenatal invasive procedures done when maternal age is the only indication. This will have the benefit of reducing the numbers of normal pregnancies lost because of complications of invasive procedures. Any screening test has an inherent false-positive rate, which may result in undue anxiety. It is not possible at this time to undertake a detailed cost-benefit analysis of the implementation of this guideline, since this would require health surveillance and research and health resources not presently available; however, these factors need to be evaluated in a prospective approach by provincial and territorial initiatives. RECOMMENDATIONS 1. All pregnant women in Canada, regardless of age, should be offered, through an informed counselling process, the option of a prenatal screening test for the most common clinically significant fetal aneuploidies in addition to a second trimester ultrasound for dating, assessment of fetal anatomy, and detection of multiples. (I-A) 2. Counselling must be non-directive and must respect a woman's right to accept or decline any or all of the testing or options offered at any point in the process. (III-A) 3. Maternal age alone is a poor minimum standard for prenatal screening for aneuploidy, and it should not be used a basis for recommending invasive testing when non-invasive prenatal screening for aneuploidy is available. (II-2A) 4. Invasive prenatal diagnosis for cytogenetic analysis should not be performed without multiple marker screening results except for women who are at increased risk of fetal aneuploidy (a) because of ultrasound findings, (b) because the pregnancy was conceived by in vitro fertilization with intracytoplasmic sperm injection, or (c) because the woman or her partner has a history of a previous child or fetus with a chromosomal abnormality or is a carrier of a chromosome rearrangement that increases the risk of having a fetus with a chromosomal abnormality. (II-2E) 5. At minimum, any prenatal screen offered to Canadian women who present for care in the first trimester should have a detection rate of 75% with no more than a 3% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 6. The minimum standard for women presenting in the second trimester should be a screen that has a detection rate of 75% with no more than a 5% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 7. First trimester nuchal translucency should be interpreted for risk assessment only when measured by sonographers or sonologists trained and accredited for this service and when there is ongoing quality assurance (II-2A), and it should not be offered as a screen without biochemical markers in singleton pregnancies. (I-E) 8. Evaluation of the fetal nasal bone in the first trimester should not be incorporated as a screen unless it is performed by sonographers or sonologists trained and accredited for this service and there is ongoing quality assurance. (II-2E) 9. For women who undertake first trimester screening, second trimester serum alpha fetoprotein screening and/or ultrasound examination is recommended to screen for open neural tube defects. (II-1A) 10. Timely referral and access is critical for women and should be facilitated to ensure women are able to undergo the type of screening test they have chosen as first trimester screening. The first steps of integrated screening (with or without nuchal translucency), contingent, or sequential screening are performed in an early and relatively narrow time window. (II-1A) 11. Ultrasound dating should be performed if menstrual or conception dating is unreliable. For any abnormal serum screen calculated on the basis of menstrual dating, an ultrasound should be done to confirm gestational age. (II-1A) 12. The presence or absence of soft markers or anomalies in the 18- to 20-week ultrasound can be used to modify the a priori risk of aneuploidy established by age or prior screening. (II-2B) 13. Information such as gestational dating, maternal weight, ethnicity, insulin-dependent diabetes mellitus, and use of assisted reproduction technologies should be provided to the laboratory to improve accuracy of testing. (II-2A) 14. Health care providers should be aware of the screening modalities available in their province or territory. (III-B) 15. A reliable system needs to be in place ensuring timely reporting of results. (III-C) 16. Screening programs should be implemented with resources that support audited screening and diagnostic laboratory services, ultrasound, genetic counselling services, patient and health care provider education, and high quality diagnostic testing, as well as resources for administration, annual clinical audit, and data management. In addition, there must be the flexibility and funding to adjust the program to new technology and protocols. (II-3B).

  4. Quantitative ELISAs for serum soluble LHCGR and hCG-LHCGR complex: potential diagnostics in first trimester pregnancy screening for stillbirth, Down’s syndrome, preterm delivery and preeclampsia

    PubMed Central

    2012-01-01

    Background Soluble LH/hCG receptor (sLHCGR) released from placental explants and transfected cells can be detected in sera from pregnant women. To determine whether sLHCGR has diagnostic potential, quantitative ELISAs were developed and tested to examine the correlation between pregnancy outcome and levels of serum sLHCGR and hCG-sLHCGR complex. Methods Anti-LHCGR poly- and monoclonal antibodies recognizing defined LHCGR epitopes, commerical anti-hCGbeta antibody, together with recombinant LHCGR and yoked hCGbeta-LHCGR standard calibrators were used to develop two ELISAs. These assays were employed to quantify serum sLHCGR and hCG-sLHCGR at first trimester human pregnancy. Results Two ELISAs were developed and validated. Unlike any known biomarker, sLHCGR and hCG-sLHCGR are unique because Down’s syndrome (DS), preeclampsia and preterm delivery are linked to both low (less than or equal to 5 pmol/mL), and high (equal to or greater than 170 pmol/mL) concentrations. At these cut-off values, serum hCG-sLHCGR together with PAPP-A detected additional DS pregnancies (21%) which were negative by free hCGbeta plus PAPP-A screening procedure. Therefore, sLHCGR/hCG-sLHCGR has an additive effect on the current primary biochemical screening of aneuploid pregnancies. More than 88% of pregnancies destined to end in fetal demise (stillbirth) exhibited very low serum hCG-sLHCGR(less than or equal to 5 pmol/mL) compared to controls (median 16.15 pmol/mL, n = 390). The frequency of high hCG-sLHCGR concentrations (equal to or greater than 170 pmol/mL) in pathological pregnancies was at least 3-6-fold higher than that of the control, suggesting possible modulation of the thyrotropic effect of hCG by sLHCGR. Conclusions Serum sLHCGR/hCG-sLHCGR together with PAPP-A, have significant potential as first trimester screening markers for predicting pathological outcomes in pregnancy. PMID:23245345

  5. Population genetics of apolipoprotein A-4, E, and H polymorphisms in Yanomami Indians of northwestern Brazil: associations with lipids, lipoproteins, and carbohydrate metabolism.

    PubMed

    Crews, D E; Kamboh, M I; Mancilha-Carvalho, J J; Kottke, B

    1993-04-01

    Using isoelectric focusing and immunoblotting techniques, we screened 96 serum samples from Yanomami Indians of northwestern Brazil to determine structural variation at three apolipoprotein loci: A4, E, and H. The APO-H locus, which is commonly polymorphic in white and black samples, was found to be monomorphic. At the APO-E locus only two alleles, APOE*3 and APOE*4, rather than the three-allele polymorphism commonly seen in Caucasians, was observed. At the APO-A4 locus no example of the APOA4*2 allele, found in Caucasians, was detected. However, the frequency of the less common APOA4*4 allele was above what has been observed in any other population. We investigated the impact of genetic variation at both polymorphic loci on quantitative differences in lipids, apolipoproteins, serum glucose, glycated hemoglobin, and uric acid. Contrary to the cholesterol-elevating effect of APOE*4 reported elsewhere, in both univariate analyses and after adjustments for age, sex, weight, and height, APOE*4 was associated with about a 4% lower mean serum cholesterol. Only after adjustment was this association statistically significant. The APOE*4 allele was significantly associated with unadjusted APO-A1 and APO-E levels but not with any other dependent variable; associations with adjusted APO-A1, APO-C2, and uric acid also approached standard levels of statistical significance (p < or = 0.05). In univariate analyses the APOA4*4 allele was significantly associated with APO-B, serum glucose, percent glycated hemoglobin, and uric acid, but no significant associations were observed after dependent variables were adjusted for age, sex, weight, and height. These results support the notion that apolipoprotein distributions and their associations with lipid and carbohydrate metabolism show ethnic variability.

  6. NY-ESO-1 autoantibody as a tumor-specific biomarker for esophageal cancer: screening in 1969 patients with various cancers.

    PubMed

    Oshima, Yoko; Shimada, Hideaki; Yajima, Satoshi; Nanami, Tatsuki; Matsushita, Kazuyuki; Nomura, Fumio; Kainuma, Osamu; Takiguchi, Nobuhiro; Soda, Hiroaki; Ueda, Takeshi; Iizasa, Toshihiko; Yamamoto, Naoto; Yamamoto, Hiroshi; Nagata, Matsuo; Yokoi, Sana; Tagawa, Masatoshi; Ohtsuka, Seiko; Kuwajima, Akiko; Murakami, Akihiro; Kaneko, Hironori

    2016-01-01

    Although serum NY-ESO-1 antibodies (s-NY-ESO-1-Abs) have been reported in patients with esophageal carcinoma, this assay system has not been used to study a large series of patients with various other cancers. Serum samples of 1969 cancer patients [esophageal cancer (n = 172), lung cancer (n = 269), hepatocellular carcinoma (n = 91), prostate cancer (n = 358), gastric cancer (n = 313), colorectal cancer (n = 262), breast cancer (n = 365)] and 74 healthy individuals were analyzed using an originally developed enzyme-linked immunosorbent assay system for s-NY-ESO-1-Abs. The optical density cut-off value, determined as the mean plus three standard deviations for serum samples from the healthy controls, was fixed at 0.165. Conventional tumor markers were also evaluated in patients with esophageal carcinoma. The positive rate of s-NY-ESO-1-Abs in patients with esophageal cancer (31 %) was significantly higher than that in the other groups: patients with lung cancer (13 %), patients with hepatocellular carcinoma (11 %), patients with prostate cancer (10 %), patients with gastric cancer (10 %), patients with colorectal cancer (8 %), patients with breast cancer (7 %), and healthy controls (0 %). The positive rate of s-NY-ESO-1-Abs was comparable to that of serum p53 antibodies (33 %), squamous cell carcinoma antigen (36 %), carcinoembryonic antigen (26 %), and CYFRA 21-1 (18 %) and gradually increased with the tumor stage. The positive rate of s-NY-ESO-1-Abs was significantly higher in patients with esophageal cancer than in patients with the other types of cancers. On the basis of its high specificity and sensitivity, even in patients with stage I tumors, s-NY-ESO-1-Abs may be one of the first choices for esophageal cancer.

  7. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    PubMed

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from

  8. Development of gel-filter method for high enrichment of low-molecular weight proteins from serum.

    PubMed

    Chen, Lingsheng; Zhai, Linhui; Li, Yanchang; Li, Ning; Zhang, Chengpu; Ping, Lingyan; Chang, Lei; Wu, Junzhu; Li, Xiangping; Shi, Deshun; Xu, Ping

    2015-01-01

    The human serum proteome has been extensively screened for biomarkers. However, the large dynamic range of protein concentrations in serum and the presence of highly abundant and large molecular weight proteins, make identification and detection changes in the amount of low-molecular weight proteins (LMW, molecular weight ≤ 30kDa) difficult. Here, we developed a gel-filter method including four layers of different concentration of tricine SDS-PAGE-based gels to block high-molecular weight proteins and enrich LMW proteins. By utilizing this method, we identified 1,576 proteins (n = 2) from 10 μL serum. Among them, 559 (n = 2) proteins belonged to LMW proteins. Furthermore, this gel-filter method could identify 67.4% and 39.8% more LMW proteins than that in representative methods of glycine SDS-PAGE and optimized-DS, respectively. By utilizing SILAC-AQUA approach with labeled recombinant protein as internal standard, the recovery rate for GST spiked in serum during the treatment of gel-filter, optimized-DS, and ProteoMiner was 33.1 ± 0.01%, 18.7 ± 0.01% and 9.6 ± 0.03%, respectively. These results demonstrate that the gel-filter method offers a rapid, highly reproducible and efficient approach for screening biomarkers from serum through proteomic analyses.

  9. Infectious bursal disease: outbreak investigation, molecular characterization, and vaccine immunogenicity trial in Ethiopia.

    PubMed

    Mekuriaw, Aregitu; Bitew, Molalegne; Gelaye, Esyas; Mamo, Bedaso; Ayelet, Gelagay

    2017-08-01

    The study was conducted with the objective of isolation and molecular characterization of infectious bursal disease virus (IBDV) circulating in Ethiopia and to assess the immunogenicity of different commercially available live attenuated IBD vaccines and finally to select the appropriate vaccine strain for the existing IBDV. Outbreak samples collected from different poultry farms with IBD infection between 2013 and 2015 were used for the virus isolation and molecular characterization. IBD vaccine immunogenicity test was conducted using four different commercially available live attenuated IBD vaccine strains: namely D78, B2K, LC75, and EXTREM. Day-old Bowman brown chickens purchased from commercial farm in Debre Zeit were used for the experiment. Serum samples were collected at days 14 and 21 and screened for the presence of maternal IBDv antibodies. The screening test result revealed that most of the chickens from vaccinated progeny were positive at the age of day 14 with mean antibody titer of .42, but declined at day 21 to 0.049 below cut-off point (S/P < 0.3). Chickens were divided into five different groups (four vaccinal and one control) and vaccinated at the age of day 21 and boosted after 14 days. Serum samples were collected and all of them were challenged at their 42 days of age with locally isolated very virulent infectious bursal disease virus (vvIBDV). From four of the vaccine strains used for immunogenicity study, the intermediate plus strains (LC75 and EXTREM) found to be superior and efficiently cross protect against the challenge with locally isolated vvIBDV. The development of clinical signs was studied and post-mortem examinations were conducted both on dead and sacrificed birds. From a total of 25 tissue samples processed for virus isolation on chicken fibroblast cell culture, 95% (18/20) of bursa and 80% (4/5) of the spleen samples showed visible cytopathic effect (CPE). The positive samples were tested by PCR and 19 of them had the expected band (643 bp). Further 11 representative samples were sequenced and confirmed that the circulating virus among poultry population in the country is vvIBDV. The study has recommended to produce vaccine using intermediate plus strains to prevent and control currently circulating vvIBDV.

  10. Serological surveillance reveals widespread influenza A H7 and H9 subtypes among chicken flocks in Egypt.

    PubMed

    Afifi, Manal A A; El-Kady, Magdy F; Zoelfakar, Sahar A; Abdel-Moneim, Ahmed Sayed; Abddel-Moneim, Ahmed Sayed

    2013-02-01

    Multiple avian influenza viruses' subtypes are circulating worldwide possessing serious threat to human populations and considered key contributors to the emergence of human influenza pandemics. This study aimed to identify the potential existence of H7 and H9 avian influenza infections circulating among chicken flocks in Egypt. Serum samples were collected from chicken flocks that experienced respiratory distresses and/or variable mortality rates. H7 and H9 virus infections were screened by haemagglutination inhibition assay using chicken erythrocytes. Serum samples were collected from 9 broiler, 12 breeder and 18 layer flocks. Out of 1,225 examined sera, 417 (34 %) from 14 flocks and 605 (49.4 %) from 21 flocks were found positive for H7 and H9, respectively. Prevalence of both H7 and H9 antibodies were higher in layer followed by breeder then broiler flocks. Special consideration should be paid to control influenza viruses in Egypt, as pandemic influenza strains may develop unnoticed given the presence of subclinical infections, and the possibility of re-assortment with the prevailing endemic H5N1 virus strains in Egypt do exist.

  11. Evaluation of a Public-sector, Provider-initiated Cryptococcal Antigen Screening and Treatment Program, Western Cape, South Africa

    PubMed Central

    Smith, Mariette; Smith, Rachel; Osler, Meg; Kelly, Nicola; Cross, Anna; Boulle, Andrew; Meintjes, Graeme; Govender, Nelesh P.

    2016-01-01

    Background Screening for serum cryptococcal antigen (CrAg) may identify those at risk for disseminated cryptococcal disease (DCD), and pre-emptive fluconazole treatment may prevent progression to DCD. In August 2012, the Western Cape Province (WC), South Africa, adopted provider-initiated CrAg screening. We evaluated the implementation and effectiveness of this large-scale public-sector program during its first year, September 1, 2012—August 31, 2013. Methods We used data from the South African National Health Laboratory Service, WC provincial HIV program, and nationwide surveillance data for DCD. We assessed the proportion of eligible patients screened for CrAg (CrAg test done within 30 days of CD4 date) and the prevalence of CrAg positivity. Incidence of DCD among those screened was compared with those not screened. Results Of 4,395 eligible patients, 26.6% (n=1170) were screened. The proportion of patients screened increased from 15.9% in September 2012 to 36.6% in August 2013. The prevalence of positive serum CrAg was 2.1%. Treatment data were available for 13 of 24 CrAg-positive patients; nine of 13 were treated with fluconazole. Nine (0.8%) incident cases of DCD occurred among the 1170 patients who were screened for CrAg vs. 49 (1.5%) incident cases among the 3225 patients not screened (p=0.07). Conclusions Relatively few eligible patients were screened under the WC provider-initiated CrAg screening program. Unscreened patients were nearly twice as likely to develop DCD. CrAg screening can reduce the burden of DCD, but needs to be implemented well. To improve screening rates, countries should consider laboratory-based reflexive screening when possible. PMID:26926942

  12. Molecular characterization of chicken infectious anemia virus from contaminated live-virus vaccines.

    PubMed

    Li, Yang; Hu, Yan; Cui, Shuai; Fu, Jiayuan; Wang, Yixin; Cui, Zhizhong; Fang, Lichun; Chang, Shuang; Zhao, Peng

    2017-05-01

    The aim of this study was to investigate possible causes of the pervasiveness of chicken infectious anemia virus (CIAV) infection in chickens in recent years in China. A total of 14 batches of live-virus vaccines were examined using PCR to detect CIAV contamination, of which only 2 samples (a Newcastle disease vaccine and a fowl pox vaccine) tested positive for CIAV. These Newcastle and fowl pox vaccines were then inoculated into 1-day-old specific-pathogen-free chickens. Serum samples were collected from chickens infected with the PCR-positive vaccines, and these tested positive for CIAV-specific antibodies as tested using ELISA. In addition, DNA samples isolated from the serum samples also tested positive by PCR. The results indicated that the samples were contaminated with CIAV and identified 2 exogenous CIAV strains, designated CIAV-N22 and CIAV-F10, in the respective samples. The full genome sequences of these novel CIAV strains were sequenced and analyzed. Phylogenetic tree analysis indicated that the CIAV-F10 strain might represent a recombinant viral strain arising from the parental CIAV strains JQ690762 and KJ728816. Overall, the results suggested that vaccination with CIAV-contaminated vaccines contributed to the prevalence and spread of CIAV infection in chickens. Furthermore, the CIAV contaminant was likely subsequently transmitted to commercial chickens through congenital transmission. Our findings therefore highlight the need for more extensive screening of live-virus vaccines for poultry in China to reduce the threat of contamination with exogenous viruses. © 2016 Poultry Science Association Inc.

  13. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  14. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  15. Prevalence of hepatitis C infection among intravenous drug users in Shanghai.

    PubMed

    Tao, Yan-Lin; Tang, Yu-Fan; Qiu, Jian-Ping; Cai, Xiao-Feng; Shen, Xiao-Ting; Wang, Ya-Xin; Zhao, Xue-Tao

    2013-08-28

    To characterize the prevalence of hepatitis C virus (HCV) infection among Chinese intravenous drug users (IDUs). A total of 432 adult IDUs (95 women and 337 men) in Shanghai were included in the study. The third-generation Elecsys Anti-HCV assay (Roche Diagnostics GmbH, Sandhofer Strasse 116, D-68305, Mannheim, Germany) was used to screen for antibodies against HCV. The RIBA strip, a supplemental anti-HCV test with high specificity, was performed on all of the samples that tested positive during the initial screening. All of the anti-HCV positive samples were analyzed with a Cobas TaqMan 48 Analyzer (Roche Diagnostics) for direct detection of HCV RNA. All of the HCV RNA-positive samples were sequenced for genotype determination. The preliminary screening identified 262 (60.6%) subjects who were seropositive for HCV. Of the 62 females and 200 males seropositive subjects, 16 (16.7%) and 65 (19.3%), respectively, were confirmed by RIBA, yielding an overall HCV seropositive rate of 18.8%. Four female (6.5%) and 14 male (7.0%) subjects tested positive for HCV RNA, indicating an active infection rate of 4.2% for the entire study population. The 18 HCV RNA-positive serum samples were genotyped. Seven individuals were genotype 1b, and four were genotype 1a. One individual each was infected with genotypes 2a, 2b and 3a. Four subjects were co-infected with multiple strains: two with genotypes 1a and 2a, and two with genotypes 1b and 2a. The active infection rate among HCV-seropositive individuals was 22.2%, which was significantly lower than most estimates. The prevalence of HCV is relatively low among IDUs in Shanghai, with a spontaneous recovery rate much higher than previous estimates.

  16. Serodiagnosis of Human Cysticercosis by Using Antigens from Vesicular Fluid of Taenia crassiceps Cysticerci

    PubMed Central

    Bueno, Ednéia C.; Snege, Miriam; Vaz, Adelaide J.; Leser, Paulo G.

    2001-01-01

    Neurocysticercosis (NC), caused by the presence of Taenia solium metacestodes in tissues, is a severe parasitic infection of the central nervous system with universal distribution. To determine the efficiency of enzyme-linked immunosorbent assay (ELISA) and immunoblot with antigens of T. crassiceps vesicular fluid (Tcra) compared to standard techniques (indirect immunofluorescence test [IFT] and complement fixation test [CFT]) using T. solium cysticerci (Tso) for the serodiagnosis of NC, we studied serum samples from 24 patients with NC, 30 supposedly healthy individuals, 76 blood bank donors, 45 individuals with other non-NC parasitoses, and 97 samples from individuals screened for cysticercosis serology (SC). The sensitivity observed was 100% for ELISA-Tso and ELISA-Tcra, 91.7% for the IFT, and 87.5% for the CFT. The specificity was 90% for ELISA-Tso, 96.7% for ELISA-Tcra, 50% for IFT, and 63.3% for CFT. The efficiency was highest for ELISA-Tcra, followed by ELISA-Tso, IFT, and CFT. Of the 23 samples from SC group, which were reactive to ELISA-Tso and/or ELISA-Tcra, only 3 were positive to immunblot-Tcra (specific peptides of 14- and 18-kDa) and to glycoprotein peptides purified from Tcra antigen (gp-Tcra), showing the low predictive value of ELISA for screening. None of the samples from the remaining groups showed specific reactivity in immunoblot-Tcra. These results demonstrate that ELISA-Tcra can be used as a screening method for the serodiagnosis of NC and support the need for specific tests for confirmation of the results. The immunoblot can be used as a confirmatory test both with Tcra and gp-Tcra, with the latter having an advantage in terms of visualization of the results. PMID:11687454

  17. Serodiagnosis of Tuberculosis in Asian Elephants (Elephas maximus) in Southern India: A Latent Class Analysis

    PubMed Central

    Dendukuri, Nandini; Cheeran, Jacob Varghese; Sukumar, Raman

    2012-01-01

    Background Mycobacterium tuberculosis, a causative agent of chronic tuberculosis disease, is widespread among some animal species too. There is paucity of information on the distribution, prevalence and true disease status of tuberculosis in Asian elephants (Elephas maximus). The aim of this study was to estimate the sensitivity and specificity of serological tests to diagnose M. tuberculosis infection in captive elephants in southern India while simultaneously estimating sero-prevalence. Methodology/Principal Findings Health assessment of 600 elephants was carried out and their sera screened with a commercially available rapid serum test. Trunk wash culture of select rapid serum test positive animals yielded no animal positive for M. tuberculosis isolation. Under Indian field conditions where the true disease status is unknown, we used a latent class model to estimate the diagnostic characteristics of an existing (rapid serum test) and new (four in-house ELISA) tests. One hundred and seventy nine sera were randomly selected for screening in the five tests. Diagnostic sensitivities of the four ELISAs were 91.3–97.6% (95% Credible Interval (CI): 74.8–99.9) and diagnostic specificity were 89.6–98.5% (95% CI: 79.4–99.9) based on the model we assumed. We estimate that 53.6% (95% CI: 44.6–62.8) of the samples tested were free from infection with M. tuberculosis and 15.9% (97.5% CI: 9.8 - to 24.0) tested positive on all five tests. Conclusions/Significance Our results provide evidence for high prevalence of asymptomatic M. tuberculosis infection in Asian elephants in a captive Indian setting. Further validation of these tests would be important in formulating area-specific effective surveillance and control measures. PMID:23166708

  18. Serodiagnosis of tuberculosis in Asian elephants (Elephas maximus) in Southern India: a latent class analysis.

    PubMed

    Verma-Kumar, Shalu; Abraham, David; Dendukuri, Nandini; Cheeran, Jacob Varghese; Sukumar, Raman; Balaji, Kithiganahalli Narayanaswamy

    2012-01-01

    Mycobacterium tuberculosis, a causative agent of chronic tuberculosis disease, is widespread among some animal species too. There is paucity of information on the distribution, prevalence and true disease status of tuberculosis in Asian elephants (Elephas maximus). The aim of this study was to estimate the sensitivity and specificity of serological tests to diagnose M. tuberculosis infection in captive elephants in southern India while simultaneously estimating sero-prevalence. Health assessment of 600 elephants was carried out and their sera screened with a commercially available rapid serum test. Trunk wash culture of select rapid serum test positive animals yielded no animal positive for M. tuberculosis isolation. Under Indian field conditions where the true disease status is unknown, we used a latent class model to estimate the diagnostic characteristics of an existing (rapid serum test) and new (four in-house ELISA) tests. One hundred and seventy nine sera were randomly selected for screening in the five tests. Diagnostic sensitivities of the four ELISAs were 91.3-97.6% (95% Credible Interval (CI): 74.8-99.9) and diagnostic specificity were 89.6-98.5% (95% CI: 79.4-99.9) based on the model we assumed. We estimate that 53.6% (95% CI: 44.6-62.8) of the samples tested were free from infection with M. tuberculosis and 15.9% (97.5% CI: 9.8 - to 24.0) tested positive on all five tests. Our results provide evidence for high prevalence of asymptomatic M. tuberculosis infection in Asian elephants in a captive Indian setting. Further validation of these tests would be important in formulating area-specific effective surveillance and control measures.

  19. Identification of Chemical Features Linked to Thyroperoxidase Inhibition (SOT)

    EPA Science Inventory

    Disruption of maternal serum thyroid hormone (TH) adversely affects fetal neurodevelopment. Therefore, assay development within the US EPA ToxCast program is ongoing to enable screening for chemicals that may disrupt TH, in support of the Endocrine Disruption Screening Program (E...

  20. [The research of establishing discriminant function for patients with angina pectoris by stepwise analysis based on serum inflammatory factors].

    PubMed

    Chen, Zhi-bin; Liang, Yan-bing; Tang, Hao; Wang, Zhong-hua; Zeng, Li-jin; Wu, Jing-guo; Li, Zhen-yu; Ma, Zhong-fu

    2012-12-01

    To improve cost-efficiency, discriminant functions in stepwise method was founded for the differential diagnosis of angina pectoris by detecting the serum level of high-sensitivity C-reactive protein (hs-CRP), macrophage migration inhibitory factor (MIF), interleukin-4 (IL-4) and interleukin-10 (IL-10) in patients with stable angina pectoris (SAP) and unstable angina pectoris (UAP). Thirty-nine SAP patients and 47 UAP patients were enrolled into the study, while 39 healthy volunteers were enrolled into the controlled group forming the entire set of training samples. The serum levels of hs-CRP, MIF, IL-4 and IL-10 were measured by enzyme linked immunosorbent assay (ELISA). Data was analyzed by software to define discriminant functions in the ways of "entering" and "stepwise". Both functions were evaluated by the results of validation. By the way of "enter independent together", the following discriminant functions were defined based on the data of training samples' age, hs-CRP, MIF, IL-4, IL-10: healthy control group =-129.858 + 2.869×age -2.451×hs-CRP + 1.393×MIF + 6.001×IL-4 + 4.848×IL-10; SAP group=-161.037 + 2.896×age-2.022×hs-CRP + 1.662×MIF + 6.703×IL-4 + 6.287×IL-10; UAP group=-199.087 + 2.468×age-1.440×hs-CRP + 3.404×MIF-13.875×IL-4 + 7.752×IL-10. Retrospective validation showed 4.8% of total miss-grouping, while cross-validation showed 5.6% of total miss-grouping. By the way of "stepwise", the above data was screened by software and training samples' age, MIF and IL-10 were suggested to define the following functions: healthy control group = - 125.218 + 2.659 × age + 0.599×MIF + 5.040 × IL-10; SAP group=-157.864 + 2.721×age + 1.008×MIF + 6.468×IL-10; UAP group=- 197.327 + 2.360×age + 2.932×MIF + 7.640×IL-10. Both retrospective and cross validation showed 6.4% of total miss-grouping. Both sets of discriminant functions had the same efficiency (100%) for differential diagnosis of SAP and UAP. The discriminant functions based on samples' age, MIF and IL-10, which were screened and suggested by stepwise method, may contribute to the differential diagnosis of atypical SAP and UAP, and therefore demonstrate better cost-efficiency.

  1. Detection and identification of serum protein peak at 6648 m/z as a novel indicator in breast cancer based on mass spectrometry.

    PubMed

    Song, Dongjian; Yue, Lifang; Zhan, Yuxiao; Zhang, Junjie; Yan, Zechen; Fan, Yingzhong; Yang, Heying; Zhang, Da; Liu, Qiuliang; Xia, Ziqiang; Qin, Pan; Jia, Jia; Yue, Ming; Yu, Jiekai; Zheng, Shu; Yang, Fuquan; Wang, Jiaxiang

    2017-05-01

    Breast cancer (BC) is the second-leading cause of cancer mortality after lung cancer in women owing partly to a lack of specific and sensitive tests for early screening and monitoring. The detection of novel specific BC serum indicators for screening purposes is an essential clinical need. A total of 437 serum specimens from 310 BC patients that were divided into mining and testing sets were collected in this study. In contrast with the conventional BC indicators through receiver operating characteristic, survival and hazard function curves, and multivariate Cox regression analyses, we intended to hunt for stable protein indicators from serum specimens and identify their diagnostic and prognostic potential for BC. We identified a unique serum peptide located at 6648 Da originated from apoC-III with a validated correlation with BC tumorigenesis with confirmation in a substantive testing set and minimization of systematic bias by pre-analytical parameters. We found that the diagnostic efficacy of this peptide is better than the present conventional BC diagnostic indicators either alone or in combination with conventional indicators in distinguishing BC patients from control volunteers. Moreover, this peptide denotes a stronger prognostic factor for BC patients than conventional indicators. In light of these findings, we speculate that this peptide is a potential diagnostic and prognostic indicator and a supplement to conventional indicators in monitoring BC. The detection of this peptide located at 6648 Da in sera could enhance early screening and assessment of the postoperative survival opportunity for BC patients.

  2. Budget impact analysis of chronic kidney disease mass screening test in Japan.

    PubMed

    Kondo, Masahide; Yamagata, Kunihiro; Hoshi, Shu-Ling; Saito, Chie; Asahi, Koichi; Moriyama, Toshiki; Tsuruya, Kazuhiko; Konta, Tsuneo; Fujimoto, Shouichi; Narita, Ichiei; Kimura, Kenjiro; Iseki, Kunitoshi; Watanabe, Tsuyoshi

    2014-12-01

    Our recently published cost-effectiveness study on chronic kidney disease mass screening test in Japan evaluated the use of dipstick test, serum creatinine (Cr) assay or both in specific health checkup (SHC). Mandating the use of serum Cr assay additionally, or the continuation of current policy mandating dipstick test only was found cost-effective. This study aims to examine the affordability of previously suggested reforms. Budget impact analysis was conducted assuming the economic model would be good for 15 years and applying a population projection. Costs expended by social insurers without discounting were counted as budgets. Annual budget impacts of mass screening compared with do-nothing scenario were calculated as ¥79-¥-1,067 million for dipstick test only, ¥2,505-¥9,235 million for serum Cr assay only and ¥2,517-¥9,251 million for the use of both during a 15-year period. Annual budget impacts associated with the reforms were calculated as ¥975-¥4,129 million for mandating serum Cr assay in addition to the currently used mandatory dipstick test, and ¥963-¥4,113 million for mandating serum Cr assay only and abandoning dipstick test. Estimated values associated with the reform from ¥963-¥4,129 million per year over 15 years are considerable amounts of money under limited resources. The most impressive finding of this study is the decreasing additional expenditures in dipstick test only scenario. This suggests that current policy which mandates dipstick test only would contain medical care expenditure.

  3. Coronavirus Infections in the Central Nervous System and Respiratory Tract Show Distinct Features in Hospitalized Children.

    PubMed

    Li, Yuanyuan; Li, Haipeng; Fan, Ruyan; Wen, Bo; Zhang, Jian; Cao, Xiaoying; Wang, Chengwu; Song, Zhanyi; Li, Shuochi; Li, Xiaojie; Lv, Xinjun; Qu, Xiaowang; Huang, Renbin; Liu, Wenpei

    2016-01-01

    Coronavirus (CoV) infections induce respiratory tract illnesses and central nervous system (CNS) diseases. We aimed to explore the cytokine expression profiles in hospitalized children with CoV-CNS and CoV-respiratory tract infections. A total of 183 and 236 hospitalized children with acute encephalitis-like syndrome and respiratory tract infection, respectively, were screened for anti-CoV IgM antibodies. The expression profiles of multiple cytokines were determined in CoV-positive patients. Anti-CoV IgM antibodies were detected in 22/183 (12.02%) and 26/236 (11.02%) patients with acute encephalitis-like syndrome and respiratory tract infection, respectively. Cytokine analysis revealed that the level of serum granulocyte colony-stimulating factor (G-CSF) was significantly higher in both CoV-CNS and CoV-respiratory tract infection compared with healthy controls. Additionally, the serum level of granulocyte macrophage colony-stimulating factor (GM-CSF) was significantly higher in CoV-CNS infection than in CoV-respiratory tract infection. In patients with CoV-CNS infection, the levels of IL-6, IL-8, MCP-1, and GM-CSF were significantly higher in their cerebrospinal fluid samples than in matched serum samples. To the best of our knowledge, this is the first report showing a high incidence of CoV infection in hospitalized children, especially with CNS illness. The characteristic cytokine expression profiles in CoV infection indicate the importance of host immune response in disease progression. © 2017 S. Karger AG, Basel.

  4. Development and Evaluation of Recombinant Nucleocapsid Protein Based Diagnostic ELISA for Detection of Nipah Virus Infection in Pigs.

    PubMed

    Kulkarni, Diwakar D; Venkatesh, Govindarajalu; Tosh, Chakradhar; Patel, Priyanka; Mashoria, Anita; Gupta, Vandana; Gupta, Sourabh; D, Senthilkumar

    2016-01-01

    The recombinant viral protein-based indirect enzyme-linked immunosorbent assay (ELISA) is a cost-effective, safe, specific, and rapid tool to diagnose the viral infection. Nipah virus nucleocapsid (NiV-N) protein was expressed in Escherichia coli and purified by histidine tag-based affinity chromatography. The N protein was selected based on its immuno dominance and conservation among different NiV strains. An indirect immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for swine sera was optimized using the recombinant NiV-N protein as an antigen along with negative and positive controls. The background reading was blocked using skim milk powder and chicken serum. A total number of 1709 swine serum samples from various states of India were tested with indirect ELISA and Western blot. The test was considered positive only when its total reactivity reading was higher than 0.2 cut-off value and the ratio of the total reactivity to the background reading was more than 2.0. Since specificity is high for Western blotting it was used as standard test for comparison of results of indirect ELISA. Sensitivity and specificity of indirect ELISA was 100% and 98.7%, respectively, in comparison with Western blotting. Recombinant N protein-based ELISA can be used in screening large number of serum samples for epidemiological investigations in developing countries where high containment laboratories are not available to handle this zoonotic virus.

  5. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    PubMed

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  6. Serum miRNAs as Biomarkers for the Diagnosis and Prognosis of Thyroid Cancer: A Comprehensive Review of the Literature.

    PubMed

    Mahmoudian-Sani, Mohammad-Reza; Mehri-Ghahfarrokhi, Ameneh; Asadi-Samani, Majid; Mobini, Gholam-Reza

    2017-07-01

    Thyroid cancer is the most common endocrine malignancy and accounts for 1% of cancers. In recent years, there has been much interest in the feasibility of using miRNAs or miRNA panels as biomarkers for the diagnosis of thyroid cancer. miRNAs are noncoding RNAs with 21-23 nucleotides that are highly conserved during evolution. They have been proposed as regulators of gene expression, apoptosis, cancer, and cell growth and differentiation. The Directory of Open Access Journals (DOAJ), Google Scholar, PubMed (NLM), LISTA (EBSCO), and Web of Science were searched. The serum level of miRNAs (miRNA-375, 34a, 145b, 221, 222, 155, Let-7, 181b) can be used as molecular markers for the diagnosis and prognosis of thyroid cancer in the serum samples of patients with thyroid glands. Given that most common methods for the screening of thyroid cancer cannot detect the disease in its early stages, identifying miRNAs that are released in the bloodstream during the gradual progression of the disease is considered a key method in the early diagnosis of thyroid cancers.

  7. Early-pregnancy maternal vitamin D status and maternal hyperglycaemia.

    PubMed

    Tomedi, L E; Simhan, H N; Bodnar, L M

    2013-09-01

    To estimate the association between serum 25-hydroxyvitamin D concentrations and maternal hyperglycaemia (post-load glucose concentration ≥ 7.5 mmol/l). Pregnant women (n = 429; 61% black, 36% obese, 45% smokers) enrolled in a cohort study at <16 weeks gestation. Non-fasting blood samples were assayed for serum 25-hydroxyvitamin D at enrolment. At 24-28 weeks gestation, maternal hyperglycaemia was determined using a 50-g 1-h oral glucose challenge test. A total of 67% of women had 25-hydroxyvitamin D concentrations < 50 nmol/l and 11% had maternal hyperglycaemia. Among smokers, each 23-nmol/l increase in serum 25-hydroxyvitamin D was associated with a reduction in the odds of maternal hyperglycaemia [odds ratio: 0.30 (95% CI: 0.13, 0.68)] after adjustment for parity, race/ethnicity, age, pre-pregnancy BMI, marital status, income, family history of diabetes, and gestational age of gestational diabetes mellitus screening. Among non-smokers, we found no association between early pregnancy vitamin D status and maternal hyperglycaemia. Smoking status may modify the relationship between poor maternal vitamin D status and maternal hyperglycaemia. © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.

  8. An evaluation of the decision-making process regarding amniocentesis following a screen-positive maternal serum screen result.

    PubMed

    Kobelka, Christine; Mattman, André; Langlois, Sylvie

    2009-05-01

    To identify the decision-making factors and personal characteristics of women who opt for and against amniocentesis following a screen-positive maternal serum screen (MSS) result. A questionnaire was mailed to 597 women who were randomly selected among women in the province of British Columbia (BC) who screened positive for Down syndrome (DS) on the MSS between January and June 2005. Subjects were evenly distributed across two main parameters: screen-positive women who opted for, and declined, amniocentesis (Groups 1 and 2, respectively). Significant differences (P < 0.05) between Groups 1 and 2 include; reasons for wanting the MSS, post-positive MSS anxiety level, risk of miscarriage associated with amniocentesis, MSS risk estimate, reasons for wanting, or not wanting amniocentesis, normal fetal ultrasound, attitudes towards termination and religious beliefs. About half of all women across both groups did not find the MSS helpful in their pregnancy, primarily stating that it caused unnecessary increased anxiety. To help avoid, or at least prepare women for the likelihood of increased anxiety following a screen-positive MSS result, and help prepare them for decision making, it is important to target MSS counselling to the individuality of the patient, and address these factors before MSS is undertaken. (c) 2009 John Wiley & Sons, Ltd.

  9. Periodic health examination, 1996 update: 1. Prenatal screening for and diagnosis of Down syndrome. Canadian Task Force on the Periodic Health Examination.

    PubMed

    Dick, P T

    1996-02-15

    To make recommendations to physicians providing prenatal care on (1) whether prenatal screening for and diagnosis of Down syndrome (DS) is advisable and (2) alternative screening and diagnosis manoeuvres. "Triple-marker" screening of maternal serum levels of alpha-fetoprotein, human chorionic gonadotropin and unconjugated estriol; fetal ultrasonographic examination; amniocentesis; and chorionic villus sampling (CVS). Accuracy of detection of DS in fetuses, and risks to the mother, including psychologic distress, and to the fetus from the screening and diagnostic interventions. A MEDLINE search for relevant articles published from Jan. 1, 1966, to Mar. 31, 1994, with the use of MeSH terms "Down syndrome," "prenatal diagnosis," "screening," "prevention," "amniocentesis," "chorionic villus sampling," "ultrasonography," "anxiety," "depression" and "psychological stress" and a manual search of bibliographies, recent issues of key journals and Current Contents. The evidence-based methods and values of the Canadian Task Force on the Periodic Health Examination were used. A high value was placed on providing pregnant women with the opportunity to determine whether they are carrying a fetus with DS and to make choices concerning the termination of the pregnancy. The economic issues involved are complex and were not considered. Triple-marker screening identifies an estimated 58% of fetuses with DS, but it has an estimated rate of true-positive results of 0.1% and of false-positive results of 3.7% (given a risk cut-off of one chance in 190 of DS). These rates vary with maternal age and the risk cut-off chosen. Women with a known risk of having a fetus with DS (e.g., those who have had a previous child with DS) may benefit from a reduction in anxiety after confirmation that their fetus does not have DS. Screening allows women at low risk of having a child with DS to detect fetuses with the syndrome, but may cause psychologic distress if there is a false-positive screening test result. Up to 20% of women with positive results of screening tests may decline to undergo a subsequent amniocentesis. Amniocentesis and CVS are very accurate in diagnosing DS in fetuses and have a very low rate of serious complications for the mother. Amniocentesis is associated with a 1.7% rate of fetal loss when it is performed after 16 weeks' gestation, whereas the rate among controls is 0.7% (for a difference of 1%, 95% confidence interval 0.3% to 1.5%). CVS entails a greater risk of fetal loss than amniocentesis (odds ratio 1.32, 95% confidence interval 1.11 to 1.57). There is little evidence from controlled trials of significant associations between amniocentesis or CVS and neonatal morbidity or malformations; however, samples have been too small to show differences in rare outcomes. Results from some case-control studies suggest that CVS increases the risk of transverse limb deficiency. Costs were not considered because they are beyond the scope of this review. There is fair evidence to offer triple-marker screening through a comprehensive program to pregnant women under 35 years of age (grade B recommendation). Women given detailed information about serum-marker screening show more satisfaction with the screening than those not given this information. There is fair evidence to offer amniocentesis or CVS to pregnant women 35 years of age and older and to women with a history of a fetus with DS or of a chromosome 21 anomaly (grade B recommendation). Information on the limitations and advantages of each procedure should be offered. Triple-marker screening may be offered as an alternative to CVS or amniocentesis to pregnant women over 35. Recommendations concerning prenatal diagnosis are similar to those of the US Preventive Services Task Force, the Society of Obstetricians and Gynaecologists of Canada, the Canadian College of Medical Geneticists and the Cochrane Pregnancy and Childbirth Group. No previous specific recommendations concerning triple-maker screening exist. These guidelines were developed and endorsed by the Canadian Task Force on the Periodic Health Examination, which is funded by Health Canada and the National Health Research and Development Program.

  10. Seroepidemiology of Human Papillomavirus 16 (HPV16) L2 and Generation of L2-Specific Human Chimeric Monoclonal Antibodies

    PubMed Central

    Wang, Joshua W.; Jagu, Subhashini; Wu, Wai-Hong; Viscidi, Raphael P.; Macgregor-Das, Anne; Fogel, Jessica M.; Kwak, Kihyuck; Daayana, Sai; Kitchener, Henry; Stern, Peter L.; Gravitt, Patti E.; Trimble, Cornelia L.

    2015-01-01

    Presently, the seroprevalence of human papillomavirus (HPV) minor capsid antigen L2-reactive antibody is not well understood, and no serologic standard exists for L2-specific neutralizing antibodies. Therefore, we screened a total of 1,078 serum samples for HPV16 L2 reactivity, and these were obtained from four prior clinical studies: a population-based (n = 880) surveillance study with a high-risk HPV DNA prevalence of 10.8%, a cohort study of women (n = 160) with high-grade cervical intraepithelial neoplasia (CIN), and two phase II trials in women with high-grade vulvar intraepithelial neoplasia (VIN) receiving imiquimod therapy combined with either photodynamic therapy (PDT) (n = 19) or vaccination with a fusion protein comprising HPV16 L2, E7, and E6 (TA-CIN) (n = 19). Sera were screened sequentially by HPV16 L2 enzyme-linked immunosorbent assay (ELISA) and then Western blot. Seven of the 1,078 serum samples tested had L2-specific antibodies, but none were detectably neutralizing for HPV16. To develop a standard, we substituted human IgG1 sequences into conserved regions of two rodent monoclonal antibodies (MAbs) specific for neutralizing epitopes at HPV16 L2 residues 17 to 36 and 58 to 64, creating JWW-1 and JWW-2, respectively. These chimeric MAbs retained neutralizing activity and together reacted with 33/34 clinically relevant HPV types tested. In conclusion, our inability to identify an HPV16 L2-specific neutralizing antibody response even in the sera of patients with active genital HPV disease suggests the subdominance of L2 protective epitopes and the value of the chimeric MAbs JWW-1 and JWW-2 as standards for immunoassays to measure L2-specific human antibodies. PMID:25972404

  11. Novel biomimetic composite material for potentiometric screening of acetylcholine, a neurotransmitter in Alzheimer's disease.

    PubMed

    Sacramento, Ana S; Moreira, Felismina T C; Guerreiro, Joana L; Tavares, Ana P; Sales, M Goreti F

    2017-10-01

    This work describes a novel approach to produce an antibody-like biomimetic material. It includes preparing composite imprinted material never presented before, with highly conductive support nanostructures and assembling a high conductivity polymeric layer at low temperature. Overall, such highly conductive material may enhance the final features of electrically-based devices. Acetylcholine (ACh) was selected as target analyte, a neurotransmitter of importance in Alzheimer's disease. Potentiometric transduction was preferred, allowing quick responses and future adaptation to point-of-care requirements. The biomimetic material was obtained by bulk polymerization, where ACh was placed in a composite matrix of multiwalled carbon nanotubes (MWCNTs) and aniline (ANI). Subsequent polymerization, initiated by radical species, yielded a polymeric structure of polyaniline (PANI) acting as physical support of the composite. A non-imprinted material (NIM) having only PANI/MWCNT (without ACh) has been prepared for comparison of the biomimetic-imprinted material (BIM). RAMAN and Fourier Transform Infrared spectroscopy (FTIR), Transmission Electron microscopy (TEM), and Scanning Electron microscope (SEM) analysis characterized the structures of the materials. The ability of this biomaterial to rebind ACh was confirmed by including it as electroactive compound in a PVC/plasticizer mixture. The membranes with imprinted material and anionic additive presented the best analytical characteristics, with a sensitivity of 83.86mV decade -1 and limit of detection (LOD) of 3.45×10 -5 mol/L in HEPES buffer pH4.0. Good selectivity was observed against creatinine, creatine, glucose, cysteine and urea. The electrodes were also applied on synthetic serum samples and seemed a reliable tool for screening ACh in synthetic serum samples. The overall performance showed fast response, reusability, simplicity and low price. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry.

    PubMed

    Serafín, V; Torrente-Rodríguez, R M; González-Cortés, A; García de Frutos, P; Sabaté, M; Campuzano, S; Yáñez-Sedeño, P; Pingarrón, J M

    2018-03-01

    A sensitive amperometric immunosensor has been prepared by immobilization of capture antibodies onto gold nanoparticles (AuNPs) grafted on a screen-printed carbon electrode (SPCE) through aryl diazonium salt chemistry using 4-aminothiophenol (AuNPs-S-Phe-SPCE). The immunosensor was designed for the accurate determination of clinically relevant levels of B-type natriuretic peptide (BNP) in human serum samples. The nanostructured electrochemical platform resulted in an ordered layer of AuNPs onto SPCEs which combined the advantages of high conductivity and improved stability of immobilized biomolecules. The resulting disposable immunosensor used a sandwich type immunoassay involving a peroxidase-labeled detector antibody. The amperometric transduction was carried out at -0.20V (vs the Ag pseudo-reference electrode) upon the addition of hydroquinone (HQ) as electron transfer mediator and H 2 O 2 as the enzyme substrate. The nanostructured immunosensors show a storage stability of at least 25 days, a linear range between 0.014 and 15ngmL -1 , and a LOD of 4pgmL -1 , which is 100 times lower than the established cut-off value for heart failure (HF) diagnosis. The performance of the immunosensor is advantageously compared with that provided with immunosensors prepared by grafting SPCE with p-phenylendiamine (H 2 N-Phe-SPCE) and attaching AuNPs by immersion into an AuNPs suspension or by electrochemical deposition, as well as with immunosensors constructed using commercial AuNPs-modified SPCEs. The developed immunosensor was applied to the successful analysis of human serum from heart failure (HF) patients upon just a 10-times dilution as sample treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A Multiplexed Serum Biomarker Immunoassay Panel Discriminates Clinical Lung Cancer Patients from High-Risk Individuals Found to be Cancer-Free by CT Screening

    PubMed Central

    Bigbee, William L.; Gopalakrishnan, Vanathi; Weissfeld, Joel L.; Wilson, David O.; Dacic, Sanja; Lokshin, Anna E.; Siegfried, Jill M.

    2012-01-01

    Introduction Clinical decision-making in the setting of CT screening could benefit from accessible biomarkers that help predict the level of lung cancer risk in high-risk individuals with indeterminate pulmonary nodules. Methods To identify candidate serum biomarkers, we measured 70 cancer-related proteins by Luminex xMAP® multiplexed immunoassays in a training set of sera from 56 patients with biopsy-proven primary non small cell lung cancer and 56 age-, sex- and smoking-matched CT-screened controls. Results We identified a panel of 10 serum biomarkers – prolactin, transthyretin, thrombospondin-1, E-selectin, C-C motif chemokine 5, macrophage migration inhibitory factor, plasminogen activator inhibitor, receptor tyrosine-protein kinase, Cyfra 21.1, and serum amyloid A – that distinguished lung cancer from controls with an estimated balanced accuracy (average of sensitivity and specificity) of 76.0%±3.8% from 20-fold internal cross-validation. We then iteratively evaluated this model in independent test and verification case/control studies confirming the initial classification performance of the panel. The classification performance of the 10-biomarker panel was also analytically validated using ELISAs in a second independent case/control population further validating the robustness of the panel. Conclusions The performance of this 10-biomarker panel based model was 77.1% sensitivity/76.2% specificity in cross-validation in the expanded training set, 73.3% sensitivity/93.3% specificity (balanced accuracy 83.3%) in the blinded verification set with the best discriminative performance in Stage I/II cases: 85% sensitivity (balanced accuracy 89.2%). Importantly, the rate of misclassification of CT-screened controls was not different in most control subgroups with or without airflow obstruction or emphysema or pulmonary nodules. These biomarkers have potential to aid in the early detection of lung cancer and more accurate interpretation of indeterminate pulmonary nodules detected by screening CT. PMID:22425918

  14. Prevalence of Brucella spp in humans1

    PubMed Central

    Soares, Catharina de Paula Oliveira Cavalcanti; Teles, José Andreey Almeida; dos Santos, Aldenir Feitosa; Silva, Stemberg Oliveira Firmino; Cruz, Maria Vilma Rocha Andrade; da Silva-Júnior, Francisco Feliciano

    2015-01-01

    Objective: to determine the seroprevalence of Brucella spp in humans. Method: this is an observational study, developed with 455 individuals between 18 and 64 years old, who use the Estratégia de Saúde da Família (Brazil's family health strategy). The serum samples of volunteers underwent buffered acid antigen tests, such as screening, agar gel immunodiffusion and slow seroagglutination test in tubes and 2-Mercaptoethanol. Results: among the samples, 1.98% has responded to buffered-acid antigen, 2.85% to agar gel immunodiffusion test and 1.54% to the slow seroagglutination tests on tubes/2-Mercaptoethanol. The prevalence of Brucella spp was 4.4%, represented by the last two tests. Conclusion: the results of this research suggest that the studied population is exposed to Brucella spp infection. PMID:26487143

  15. Relationship between first trimester aneuploidy screening test serum analytes and placenta accreta.

    PubMed

    Büke, Barış; Akkaya, Hatice; Demir, Sibel; Sağol, Sermet; Şimşek, Deniz; Başol, Güneş; Barutçuoğlu, Burcu

    2018-01-01

    The aim of this study is to determine whether there is a relationship between first trimester serum pregnancy-associated plasma protein A (PAPP-A) and free beta human chorionic gonadotropin (fβhCG) MoM values and placenta accreta in women who had placenta previa. A total of 88 patients with placenta previa who had first trimester aneuploidy screening test results were enrolled in the study. Nineteen of these patients were also diagnosed with placenta accreta. As probable markers of excessive placental invasion, serum PAPP-A and fβhCG MoM values were compared in two groups with and without placenta accreta. Patients with placenta accreta had higher statistically significant serum PAPP-A (1.20 versus 0.865, respectively, p = 0.045) and fβhCG MoM (1.42 versus 0.93, respectively, p = 0.042) values than patients without accreta. Higher first trimester serum PAPP-A and fβhCG MoM values seem to be associated with placenta accreta in women with placenta previa. Further studies are needed to use these promising additional tools for early detection of placenta accreta.

  16. Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.

    PubMed

    Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C

    2014-07-01

    The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated  = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.

  17. Identification of serum analytes and metabolites associated with aerobic capacity

    USDA-ARS?s Scientific Manuscript database

    Studies aimed at identifying serum markers of cellular metabolism (biomarkers) that are associated at baseline with aerobic capacity (V02 max) in young, healthy individuals have yet to be reported. Therefore, the goal of the present study was to use the standard chemistry screen and untargeted mass ...

  18. Human T-lymphotropic virus type 1 prevalence in northeastern Iran, Sabzevar: an epidemiologic-based study and phylogenetic analysis.

    PubMed

    Azarpazhooh, Mahmoud Reza; Hasanpour, Kazem; Ghanbari, Mohsen; Rezaee, S A Rahim; Mashkani, Baratali; Hedayati-Moghaddam, Mohammad Reza; Valizadeh, Narges; Farid Hosseini, Reza; Foroghipoor, Mohsen; Soltanifar, Azadeh; Sahebari, Maryam; Azadmanesh, Keyhan; Hassanshahi, Gholahossein; Rafatpanah, Houshang

    2012-09-01

    Human T-lymphotropic virus type 1 (HTLV-I) is an important global health problem in the world mainly in the endemic areas of HTLV-I infection. It was previously reported that Mashhad, in northeastern Iran, is a new endemic region of HTLV-I. The aim of this study was to examine the prevalence and phylogenetic analysis of HTLV-I in Sabzevar, located in the southeast of Mashhad. In this cross-sectional study 1445 individuals were selected by multistage cluster sampling. Serum samples were screened for anti-HTLV-I antibody using enzyme-linked immunosorbent assay (ELISA); all of the ELISA-positive samples were confirmed by polymerase chain reaction (PCR). Long terminal repeat (LTR) sequencing was carried out to determine the type of HTLV-I in Sabzevar. In the primary screening by ELISA, 26/1445 (1.8%) of those sampled were reactive for HTLV-I antibody. Twenty-four out of 26 samples were confirmed HTLV-I infection by PCR (24/1445). The overall prevalence of HTLV-I infection in Sabzevar is 1.66%. The prevalence of the virus infection in men and women was 2.42% (11/455) and 1.31% (13/989), respectively. Seroprevalence was associated with age, increasing significantly among those older than 30 years (p=0.015), and a history of surgery (p=0.002), imprisonment (p=0.018), and hospitalization (p=0.005). Three out of 24 positive HTLV-I samples were selected for sequencing and phylogenetic analysis of LTR. The results showed that HTLV-I in Sabzevar belonged to the cosmopolitan subtype. The present study showed Sabzevar is a new endemic area for HTLV-I infection. Our study emphasizes that systemic HTLV-I screening of blood donors in Sabzevar and other cities in Khorasan province is important and should be taken into account.

  19. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan.

    PubMed

    Laperche, Syria; Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-07-01

    Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. Copyright © 2017 Laperche et al.

  20. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan

    PubMed Central

    Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-01-01

    ABSTRACT Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. PMID:28468860

  1. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  2. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  3. Correlation between serum total globulins and gamma globulins and their use to diagnose failure of passive transfer in foals.

    PubMed

    Fouché, Nathalie; Graubner, Claudia; Howard, Judith

    2014-11-01

    Various assays have been used as an aid to diagnose failure of passive transfer (FPT) of immunoglobulins in neonatal foals, but often lack sensitivity as screening tests, or are time consuming to perform and impractical as confirmatory tests. The aim of the present study was to evaluate whether measurement of serum total globulins (TG; i.e. total protein minus albumin) can be used to estimate the electrophoretic gamma globulin (EGG) fraction in hospitalised neonatal foals with suspected FPT. Sample data from 56 foals were evaluated retrospectively. The coefficient of rank correlation was 0.84. The area under the curve of ROC analysis was 0.887, 0.922 and 0.930 for EGG concentrations <2 g/L, < 4 g/L and <8 g/L, respectively. Cut-offs for TG achieved ≥90% sensitivity for detecting EGG <2 g/L, < 4 g/L and <8 g/L, with negative predictive values of >97% and >94%, using prevalence of 15% and 30%, respectively. These results suggest that measurement of TG can be used as a guide to predicting EGG, provided that appropriate cut-off values are selected, and this technique could be a useful initial screening test for FPT in foals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Downregulation of serum metabolite GTA-446 as a novel potential marker for early detection of colorectal cancer.

    PubMed

    Hata, Tsuyoshi; Takemasa, Ichiro; Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Mizushima, Tsunekazu; Doki, Yuichiro; Mori, Masaki

    2017-07-11

    We previously reported that GTA-446 may be a useful biomarker for early detection of colorectal cancer. In the present study, we confirmed the clinical feasibility of GTA-446 as a screening tool for colorectal cancer with a novel measurement system developed for clinical use. We also improved sensitivity by analysing GTA-446 levels according to gender. Serum samples were collected from 225 colorectal cancer patients and 916 healthy volunteers to measure GTA-446 levels by flow injection analysis-mass spectrometry. GTA-446 levels were downregulated in colorectal cancer patients compared with the healthy volunteers, and in females compared with the males in both groups. Receiver operating characteristic curve analysis revealed an optimal cut-off of 2.72 μmol l -1 in males and 1.87 μmol l -1 in females, with a large area under the curve of 0.89-0.93. The sensitivity and specificity were 90.4% and 84.9% for males, 85.2% and 80.5% for females, and 83.3% and 84.8% for all subjects, respectively. GTA-446 is a clinically relevant biomarker for colorectal cancer with high sensitivity when analysed by gender. Thus, GTA-446 is a promising tool for primary colorectal cancer screening to identify populations at a higher risk of colorectal cancer, with an emphasis on early detection.

  5. The investigation of immunoprotective and sedative hypnotic effect of total polysaccharide from Suanzaoren decoction by serum metabonomics approach.

    PubMed

    Niu, Xiaoyi; He, Bosai; Du, Yiyang; Sui, Zhenyu; Rong, Weiwei; Wang, Xiaotong; Li, Qing; Bi, Kaishun

    2018-06-01

    Suanzaoren decoction, as one of the traditional Chinese medicine prescriptions, has been most commonly used in Asian countries and reported to inhibit the process of immunodeficiency insomnia. Polysaccharide is important component which also contributes to the role of immunoprotective and sedative hypnotic effects. This study was aimed to explore the immunoprotective and sedative hypnotic mechanisms of polysaccharide from Suanzaoren decoction by serum metabonomics approach. With this purpose, complex physical and chemical immunodeficiency insomnia models were firstly established according to its multi-target property. Serum samples were analyzed using UHPLC/Q-TOF-MS spectrometry approach to determine endogenous metabolites. Then, principal component analysis was used to distinguish the groups, and partial least squares discriminate analysis was carried out to confirm the important variables. The serum metabolic profiling was identified and pathway analysis was performed after the total polysaccharide administration. The twenty-one potential biomarkers were screened, and the levels were all reversed to different degrees in the total polysaccharide treated groups. These potential biomarkers were mainly related to vitamin, sphingolipid, bile acid, phospholipid and acylcarnitine metabolisms. The result has indicated that total polysaccharide could inhibit insomnia triggered by immunodeficiency stimulation through regulating those metabolic pathways. This study provides a useful approach for exploring the mechanism and evaluating the efficacy of total polysaccharide from Suanzaoren decoction. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. POSTNATAL SERUM INSULIN-LIKE GROWTH FACTOR I AND RETINOPATHY OF PREMATURITY.

    PubMed

    Jensen, Anne K; Ying, Gui-Shuang; Huang, Jiayan; Quinn, Graham E; Binenbaum, Gil

    2017-05-01

    Low serum IGF-1 has been associated with development of severe ROP, but no U.S. studies have been reported. We sought to determine the relationship between postnatal serum IGF-1 levels and severe ROP in a racially diverse U.S. cohort. Prospective cohort study of 74 infants with birth weight <1,251 g and a known ROP outcome at 3 Philadelphia hospitals. Weekly postnatal filter paper blood spot IGF-1 assays were measured through 42 weeks postmenstrual age. The cohort included 20 white, 45 black, 2 Asian, and 9 other infants; median gestational age was 27.6 weeks (range 23-33 weeks), and median birth weight was 975 g (range 490-1,250 g). During postmenstrual age Weeks 28 to 33, mean IGF-1 was 20.0 ng/mL (standard error 0.52) for no ROP (n = 46), 18.0 (0.49) for Stage 1 or 2 (n = 23), and 17.0 (0.70) for Stage 3 (n = 5, 2 lasered) (P = 0.003). Adjustment for birth weight and gestational age showed similar results. The presence and timing of an association between low postnatal serum IGF and ROP in a racially diverse U.S. sample were found to be consistent with those of European cohorts. This association provides the pathophysiological basis for growth-based predictive models, which could improve efficiency of ROP screening.

  7. Potential of soluble CD26 as a serum marker for colorectal cancer detection

    PubMed Central

    Cordero, Oscar J; Imbernon, Monica; Chiara, Loretta De; Martinez-Zorzano, Vicenta S; Ayude, Daniel; de la Cadena, Maria Paez; Rodriguez-Berrocal, F Javier

    2011-01-01

    Colorectal cancer is characterized by a low survival rate even though the basis for colon cancer development, which involves the evolution of adenomas to carcinoma, is known. Moreover, the mortality rates continue to rise in economically transitioning countries although there is the opportunity to intervene in the natural history of the adenoma–cancer sequence through risk factors, screening, and treatment. Screening in particular accounted for most of the decline in colorectal cancer mortality achieved in the USA during the period 1975-2000. Patients show a better prognosis when the neoplasm is diagnosed early. Among the variety of screening strategies, the methods range from invasive and costly procedures such as colonoscopy to more low-cost and non-invasive tests such as the fecal occult blood test (guaiac and immunochemical). As a non-invasive biological serum marker would be of great benefit because of the performance of the test, several biomarkers, including cytologic assays, DNA and mRNA, and soluble proteins, have been studied. We found that the soluble CD26 (sCD26) concentration is diminished in serum of colorectal cancer patients compared to healthy donors, suggesting the potential utility of a sCD26 immunochemical detection test for early diagnosis. sCD26 originates from plasma membrane CD26 lacking its transmembrane and cytoplasmic domains. Some 90%–95% of sCD26 has been associated with serum dipeptidyl peptidase IV (DPP-IV) activity. DPP-IV, assigned to the CD26 cluster, is a pleiotropic enzyme expressed mainly on epithelial cells and lymphocytes. Our studies intended to validate this test for population screening to detect colorectal cancer and advanced adenomas are reviewed here. PMID:21773075

  8. Screening of carnitine and biotin deficiencies on tandem mass spectrometry.

    PubMed

    Hagiwara, Shin-Ichiro; Kubota, Mitsuru; Nambu, Ryusuke; Kagimoto, Seiichi

    2017-04-01

    It is important to assess pediatric patients for nutritional deficiency when they are receiving specific interventions, such as enteral feeding. We focused on measurement of C0 and 3-hydroxyisovalerylcarnitine (C5-OH) with tandem mass spectrometry (MS/MS), which is performed as part of the newborn mass screening. The purpose of this study was to investigate the usefulness of MS/MS for screening carnitine and biotin deficiencies. Forty-two children (24 boys, 18 girls) were enrolled between December 2013 and December 2015. Blood tests, including measurement of serum free carnitine via the enzyme cycling method, and acylcarnitine analysis on MS/MS of dried blood spot (DBS), were performed for the evaluation of nutrition status. Median patient age was 2 years (range, 2 months-14 years). Mean serum free carnitine was 41.8 ± 19.2 μmol/L. In six of the 42 patients, serum free carnitine was <20 μmol/L (range, 4.0-18.7 μmol/L). C0 and C5-OH measured on MS/MS of DBS were 33.8 ± 20.2 nmol/mL and 0.48 ± 0.22 nmol/mL, respectively. There was a strong positive correlation (r = 0.89, P < 0.001) between serum free carnitine and C0 measured on the same day. In one patient on hydrolyzed formula, C5-OH was >1.00 nmol/L. Therapy-resistant eczema was improved by treatment with additional biotin and a non-hydrolyzed formula. C0 and C5-OH, measured on MS/MS of DBS, were useful for screening carnitine and biotin deficiencies. © 2016 Japan Pediatric Society.

  9. Use of preventive care by the working poor in the United States

    PubMed Central

    Ross, Joseph S.; Bernheim, Susannah M.; Bradley, Elizabeth H.; Teng, Hsun-Mei; Gallo, William T.

    2007-01-01

    Objective Examine the association between poverty and preventive care use among older working adults. Method Cross-sectional analysis of the pooled 1996, 1998 and 2000 waves of the Health and Retirement Study, a nationally representative sample of older community-dwelling adults, studying self-reported use of cervical, breast, and prostate cancer screening, as well as serum cholesterol screening and influenza vaccination. Adults with incomes within 200% of the federal poverty level were defined as poor. Results Among 10,088 older working adults, overall preventive care use ranged from 38% (influenza vaccination) to 76% (breast cancer screening). In unadjusted analyses, the working poor were significantly less likely to receive preventive care. After adjustment for insurance coverage, education, and other socio-demographic characteristics, the working poor remained significantly less likely to receive breast cancer (RR 0.92, 95% CI, 0.86–0.96), prostate cancer (RR 0.89, 95% CI, 0.81–0.97), and cholesterol screening (RR 0.91, 95% CI, 0.86–0.96) than the working non-poor, but were not significantly less likely to receive cervical cancer screening (RR 0.96, 95% CI, 0.90–1.01) or influenza vaccination (RR 0.92, 95% CI, 0.84–1.01). Conclusion The older working poor are at modestly increased risk for not receiving preventive care. PMID:17196642

  10. First trimester combined test for Down syndrome screening in unselected pregnancies - a report of a 13-year experience.

    PubMed

    Lee, Fa-Kung; Chen, Li-Ching; Cheong, Mei-Leng; Chou, Ching-Yu; Tsai, Ming-Song

    2013-12-01

    To analyze the performance of the first trimester Down syndrome screening in a single medical center in Northern Taiwan. From April 1999 to June 2012, a total of 25,104 pregnant women at gestational age of 10 weeks to 13 weeks 6 days received first trimester "combined test" for Down syndrome screening. The test combines the ultrasound scan of nuchal translucency thickness and maternal biochemical serum levels of pregnancy-associated plasma protein A (PAPP-A) and free beta-human chorionic gonadotropin (β-hCG). A positive screen was defined as an estimated Down syndrome risk ≥ 1/270, and either chorionic villous sampling or amniocentesis was performed for fetal chromosomal analyses. Seventy-eight of the 25,104 pregnancies were proven to have fetal chromosome anomalies. The detection rates for trisomy 21, trisomy 18, Turner syndrome, and other chromosome anomalies were 87.5% (21/24), 69.2% (9/13), 81.8% (9/11), and 60% (18/30), respectively, with a false positive rate (FPR) of 5.4% (1353/25,026). Further evaluation of the detection rates for trisomy 21, by gestational age at 11, 12, and 13 weeks, were 92.3%, 87.5%, and 66.7%, respectively. The first trimester combined test is an effective screening tool for Down syndrome detection with an acceptable low false positive rate. The best timing of screening will be between 11 and 12 weeks' gestation. Copyright © 2013. Published by Elsevier B.V.

  11. Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening

    PubMed Central

    Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.

    2009-01-01

    PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838

  12. Novel heparan sulfate assay by using automated high-throughput mass spectrometry: application to monitoring and screening for mucopolysaccharidoses

    PubMed Central

    Shimada, Tsutomu; Kelly, Joan; LaMarr, William A; van Vlies, Naomi; Yasuda, Eriko; Mason, Robert W.; Mackenzie, William; Kubaski, Francyne; Giugliani, Roberto; Chinen, Yasutsugu; Yamaguchi, Seiji; Suzuki, Yasuyuki; Orii, Kenji E.; Fukao, Toshiyuki; Orii, Tadao; Tomatsu, Shunji

    2014-01-01

    Mucopolysaccharidoses (MPS) are caused by deficiency of one of a group of specific lysosomal enzymes, resulting in excessive accumulation of glycosaminoglycans (GAGs). We previously developed GAG assay methods using liquid chromatography tandem mass spectrometry (LC-MS/MS); however, it takes 4–5 min per sample for analysis. For the large numbers of samples in a screening program, a more rapid process is desirable. The automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) integrates a solid phase extraction robot to concentrate and desalt samples prior to direction into the MS/MS without chromatographic separation; thereby allowing each sample to be processed within ten seconds (enabling screening of more than one million samples per year). The aim of this study was to develop a higher throughput system to assay heparan sulfate (HS) using HT-MS/MS, and to compare its reproducibility, sensitivity and specificity with conventional LC-MS/MS. HS levels were measured in blood (plasma and serum) from control subjects and patients with MPS II, III, or IV and in dried blood spots (DBS) from newborn controls and patients with MPS I, II, or III. Results obtained from HT-MS/MS showed 1) that there was a strong correlation of levels of disaccharides derived from HS in blood, between those calculated using conventional LC-MS/MS and HT-MS/MS, 2) that levels of HS in blood were significantly elevated in patients with MPS II and III, but not in MPS IVA, 3) that the level of HS in patients with a severe form of MPS II was higher than that in an attenuated form, 4) that reduction of blood HS level was observed in MPS II patients treated with enzyme replacement therapy or hematopoietic stem cell transplantation, and 5) that levels of HS in newborn DBS were elevated in patients with MPS I, II or III, compared to control newborns. In conclusion, HT-MS/MS provides much higher throughput than LC-MS/MS-based methods with similar sensitivity and specificity in an HS assay, indicating that HT-MS/MS may be feasible for diagnosis, monitoring, and newborn screening of MPS. PMID:25092413

  13. A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid.

    PubMed

    Wang, Yijia; Zeinhom, Mohamed M A; Yang, Mingming; Sun, Rongrong; Wang, Shengfu; Smith, Jordan N; Timchalk, Charles; Li, Lei; Lin, Yuehe; Du, Dan

    2017-09-05

    Onsite rapid detection of herbicides and herbicide residuals in environmental and biological specimens are important for agriculture, environmental concerns, food safety, and health care. The traditional method for herbicide detection requires expensive laboratory equipment and a long turnaround time. In this work, we developed a single-stripe microliter plate smartphone-based colorimetric device for rapid and low-cost in-field tests. This portable smartphone platform is capable of screening eight samples in a single-stripe microplate. The device combined the advantages of small size (50 × 100 × 160 mm 3 ) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and rhodamine B, for the red and green channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for detection of the herbicide 2,4-dichlorophenoxyacetic acid in the range of 1 to 80 ppb. Spiked samples of tap water, rat serum, plasma, and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all of the spiked samples using the microplate reader and from 93.7% to 106.9% for all of the samples using the smartphone device. This work validated that the smartphone optical-sensing platform is comparable to the commercial microplate reader; it is eligible for onsite, rapid, and low-cost detection of herbicides for environmental evaluation and biological monitoring.

  14. Human Puumala and Dobrava Hantavirus Infections in the Black Sea Region of Turkey: A Cross-Sectional Study

    PubMed Central

    Kalaycioglu, Handan; Uyar, Yavuz; Sevindi, Demet Furkan; Turkyilmaz, Bedia; Çakir, Vedat; Cindemir, Cengiz; Unal, Belgin; Yağçi-Çağlayik, Dilek; Korukluoglu, Gulay; Ertek, Mustafa; Heyman, Paul; Lundkvist, Åke

    2013-01-01

    Abstract This study was carried out to better understand the epidemiology of hantaviruses in a province of Turkey (Giresun) where human hantavirus disease has recently been detected. In this cross-sectional study, a total of 626 blood samples from healthy people aged 15 and 84 years old were collected both in urban and rural areas in 2009. The sera were tested by enzyme-linked immunosorbent assay (ELISA), immunoblotting assay, and the focus reduction neutralization test (FRNT). We screened the samples by an ELISA and found that 65/626 samples reacted positively for the presence of hantavirus-reactive immunoglobulin G (IgG). Twenty of the 65 ELISA-positive samples could be confirmed by an immunobloting assay, and the overall seroprevalence was thereby calculated to 3.2% (20/626). The seroprevalence of the people living in wood areas or adobe houses 9/17 (52.9%) was significantly higher than among people living in concrete houses 10/47 (21.3%) (p=0.014). Finally, 3 of the 20 immunoblot-positive sera were confirmed as specific for the Puumala hantavirus serotype by FRNT, 1 serum was confirmed as Dobrava virus-specific, whereas 1 serum was found to be equally reactive to Dobrava and Saaremaa viruses. We will now focus on further investigations of the ecology and epidemiology of hantaviruses in humans and their carrier animals in Turkey, studies that have already been started and will be further intensified. PMID:23289396

  15. Evaluation of a monoclonal antibody-based latex agglutination test for diagnosis of cryptococcosis: comparison with two tests using polyclonal antibodies.

    PubMed Central

    Temstet, A; Roux, P; Poirot, J L; Ronin, O; Dromer, F

    1992-01-01

    Cryptococcal antigen detection has become a routine biological test performed for patients with AIDS. The poor prognosis of cryptococcosis explains the need for reliable tests. We evaluated the performances of a newly commercialized agglutination test that uses a monoclonal antibody specific for cryptococcal capsular polysaccharide (Pastorex Cryptococcus; Sanofi-Diagnostics Pasteur, Marnes-la-Coquette, France) and compared them with those of tests that use polyclonal immune sera (Cryptococcal Antigen Latex Agglutination System, Meridian Diagnostics, Inc., Cincinnati, Ohio; and Crypto-LA, International Biological Labs Inc., Cranbury, N.J.). The sensitivities and specificities of the tests were compared by using purified polysaccharides and yeast suspensions. Clinical specimens (131 serum samples, 41 cerebrospinal fluid samples, 34 urine samples, and 19 bronchoalveolar lavage samples) from 87 human immunodeficiency virus-positive subjects with (40 patients) and without (47 patients) culture-proven cryptococcosis were retrospectively tested during a blinded study. The effect of pronase treatment of samples was assessed for Pastorex Cryptococcus and the Cryptococcal Antigen Latex Agglutination System, and the antigen titers were compared. Our results show that (i) during the screening, concordance among the three tests was 97%; (ii) the use of pronase enhanced both the sensitivities and specificities of the Pastorex Cryptococcus test; (iii) titers agreed for 67% of the cerebrospinal fluid samples and 60% of the serum samples; and (iv) cryptococcosis was detected equally well with Pastorex Cryptococcus and with the other tests, whatever the infecting serotype (A, B, or D). The meaning of in vitro sensitivity and the relationship between titers and sensitivity are discussed. The results show that Pastorex Cryptococcus is a rapid and reliable test for the detection of cryptococcal antigen in body fluids and suggest that kits cannot be used interchangeably to monitor antigen titers in patients. PMID:1400951

  16. Programmable Bio-Nano-Chip Systems for Serum CA125 Quantification: Towards Ovarian Cancer Diagnostics at the Point-of-Care

    PubMed Central

    Raamanathan, Archana; Simmons, Glennon W.; Christodoulides, Nicolaos; Floriano, Pierre N.; Furmaga, Wieslaw B.; Redding, Spencer W.; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.

    2013-01-01

    Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, modular (Programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multi-modal and multi-marker screening approaches. In the p-BNC, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a 3-D microfluidic environment, the p-BNC operating variables (incubation times, flow rates and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (Inter- and intra-assay precision of 1.2% and 1.9% and LODs of 1.0 U/mL) was achieved on this mini-sensor ensemble. Further validation with sera of ovarian cancer patients (n=20) demonstrated excellent correlation (R2 = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics. PMID:22490510

  17. Programmable bio-nano-chip systems for serum CA125 quantification: toward ovarian cancer diagnostics at the point-of-care.

    PubMed

    Raamanathan, Archana; Simmons, Glennon W; Christodoulides, Nicolaos; Floriano, Pierre N; Furmaga, Wieslaw B; Redding, Spencer W; Lu, Karen H; Bast, Robert C; McDevitt, John T

    2012-05-01

    Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.

  18. Critical congenital heart defects and abnormal levels of routinely collected first- and second-trimester biomarkers.

    PubMed

    Borelli, Melissa; Baer, Rebecca J; Chambers, Christina D; Smith, Tyler C; Jelliffe-Pawlowski, Laura L

    2017-02-01

    We examined the association between maternal characteristics, routinely collected first- and second-trimester biomarkers and the risk of having an infant with a critical congenital heart defect (CCHD). Included were women who participated in the California Prenatal Screening Program who had nuchal translucency (NT) measurement and first- and second-trimester serum screening. All pregnancies ended in a live birth of an infant without aneuploidy or a neural tube defect. Poisson regression analyses were used to estimate the relative risk and 95% confidence interval of a CCHD by maternal characteristics, first- and second-trimester serum biomarkers or NT measurements. The sample included 118,194 mother-infant pairs; 284 infants had a CCHD. Women with preexisting diabetes were three-times as likely to have an infant with a CCHD. After adjusting for preexisting diabetes, women with first-trimester human chorionic gonatotropin (hCG) measurement <10th centile were 1.6-times as likely to have an infant with a CCHD (P = 0.011). Women with a NT measurement ≥95th centile were at two- to threefold higher risk of having an infant with a CCHD (P's = 0.004-0.007). Pregnancies with two risk factors for an infant with a CCHD were 5.6-times more likely to have an infant with a CCHD than women with no identified risk factors (P < 0.001). Despite the increased risk, performance testing demonstrated low sensitivity and specificity for screening use of these risk factors. Of the women with an infant with a CCHD, only 21.8% had an identified risk factor. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Syphilis screening in out-of-hospital care.

    PubMed

    Marvez-Valls, E; Weiss, S J; Ernst, A A; Johnson, W D

    1995-07-01

    To estimate the rates of syphilis infection in inner-city patients managed by prehospital providers, a convenience sampling of prehospital patients who had intravenous lines initiated was screened for syphilis over a nine-month study period from February 1992 through October 1992. In a university-affiliated inner-city emergency department served by a city ambulance company, patients 18 years of age or older transported via ambulance who had had intravenous lines initiated at the scene or en route had a Venereal Disease Research Laboratory (VDRL) and microhemagglutination-Treponema pallidum (MHA-TP) drawn and performed by the state laboratory as a routine serological test. If the results were reactive with no previous history of syphilis recorded in the state registry, the state health department and/or one of the authors of this study contacted the patient for follow-up treatment. Age, race, sex, and diagnostic category (medical, surgical/obstetric, or neuropsychiatric) were recorded. Results were checked with the state syphilis registry. Latent syphilis was defined as a reactive VDRL and MHA-TP with no prior history of infection or record of infection in the state syphilis registry. Chi-squared test was used in statistical analysis for comparisons among ages, races, and sexes, with P > .05 considered significant. Three hundred two subjects 18 years of age and older consenting to a screening VDRL and MHA-TP had serum drawn. Two hundred seventy-nine patients were enrolled in the study after 23 patients were excluded because of improper data collection or insufficient serum collection. There were 174 men (63%) and 105 women (37%), with 73 white (26%) and 199 African-Americans (71%).(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Antenatal Screening for Hypothyroidism and Childhood Cognitive Impairment

    PubMed Central

    Lazarus, John H.; Bestwick, Jonathan P.; Channon, Sue; Paradice, Ruth; Maina, Aldo; Rees, Rhian; Chiusano, Elisabetta; John, Rhys; Guaraldo, Varvara; George, Lynne M.; Perona, Marco; Dall’Amico, Daniela; Parkes, Arthur B.; Jooman, Mohammed; Wald, Nicholas J.

    2013-01-01

    Background Children born to women with low thyroid hormone levels have been reported to have decreased cognitive function. Methods We conducted a randomized trial in which pregnant women at a gestation of 15 weeks 6 days or less provided blood samples for measurement of thyrotropin and free thyroxine (T4). Women were assigned to a screening group (in which measurements were obtained immediately) or a control group (in which serum was stored and measurements were obtained shortly after delivery). Thyrotropin levels above the 97.5th percentile, free T4 levels below the 2.5th percentile, or both were considered a positive screening result. Women with positive findings in the screening group were prescribed 150 μg of levothyroxine per day. The primary outcome was IQ at 3 years of age in children of women with positive results, as measured by psychologists who were unaware of the group assignments. Results Of 21,846 women who provided blood samples (at a median gestational age of 12 weeks 3 days), 390 women in the screening group and 404 in the control group tested positive. The median gestational age at the start of levothyroxine treatment was 13 weeks 3 days; treatment was adjusted as needed to achieve a target thyrotropin level of 0.1 to 1.0 mIU per liter. Among the children of women with positive results, the mean IQ scores were 99.2 and 100.0 in the screening and control groups, respectively (difference, 0.8; 95% confidence interval [CI], −1.1 to 2.6; P = 0.40 by intention-to-treat analysis); the proportions of children with an IQ of less than 85 were 12.1% in the screening group and 14.1% in the control group (difference, 2.1 percentage points; 95% CI, −2.6 to 6.7; P = 0.39). An on-treatment analysis showed similar results. Conclusions Antenatal screening (at a median gestational age of 12 weeks 3 days) and maternal treatment for hypothyroidism did not result in improved cognitive function in children at 3 years of age. (Funded by the Wellcome Trust UK and Compagnia di San Paulo, Turin; Current Controlled Trials number, ISRCTN46178175.) PMID:22316443

  1. Hematologic Parameters and Viral Status for Zika, Chikungunya, Bluetongue, and Epizootic Hemorrhagic Disease in White-tailed Deer ( Odocoileus virginianus) on St John, US Virgin Islands.

    PubMed

    Reuter, Jon D; Nelson, Suzanne L

    2018-05-24

    A population of white-tailed deer ( Odocoileus virginianus) resides throughout the island of St John, US Virgin Islands, predominately in the Virgin Islands National Park. Adult deer ( n=23), ranging from 1 yr to 8 yr old, were assessed to characterize body condition and health. Serologic samples were screened for important viral pathogens in the area, including Zika, chikungunya, bluetongue, and epizootic hemorrhagic disease viruses. Samples were collected in July 2016; males were in velvet and all females were in diestrus. Deer had recovered from a severe drought the previous year but were generally healthy, with a low-level but high incidence of tick parasitism. Marked statistically significant changes in hematocrit and hemoglobin levels were associated with the effects of the anesthetic mixture used for capture. No other statistically significant differences were observed. Serum from four deer induced reduction in Zika virus plaques, suggesting possible exposure. No serum was reactive for chikungunya virus. Bluetongue and epizootic hemorrhagic disease antibodies were present in 50% of the sampled deer, but no clinical signs associated with disease were observed during the study period. These data will be valuable for future dynamic health assessment and may help assess changes to the population, such as those induced by climate change, infectious disease, or other demographic events.

  2. Serum ferritin concentrations and body iron stores in a multicenter, multiethnic primary-care population

    PubMed Central

    Gordeuk, Victor R.; Reboussin, David M.; McLaren, Christine E.; Barton, James C.; Acton, Ronald T.; McLaren, Gordon D.; Harris, Emily L.; Reiss, Jacob A.; Adams, Paul C.; Speechley, Mark; Phatak, Pradyumna D.; Sholinsky, Phyliss; Eckfeldt, John H.; Chen, Wen-Pin; Passmore, Leah; Dawkins, Fitzroy W.

    2013-01-01

    How often elevated serum ferritin in primary-care patients reflects increased iron stores (normally 0.8 g in men, 0.4 g in women) is not known. The Hereditary Hemochromatosis and Iron Overload Screening (HEIRS) study screened 101,168 primary-care participants (44% Caucasians, 27% African-Americans, 14% Asians/Pacific Islanders, 13% Hispanics, 2% others). Follow-up clinical evaluation was performed in 302 of 333 HFE C282Y homozygotes regardless of iron measures and 1,375 of 1,920 nonhomozygotes with serum ferritin >300 μg/L (men), >200 μg/L (women) and transferrin saturation >50% (men), >45% (women). Quantitative phlebotomy was conducted in 122 of 175 C282Y homozygotes and 122 of 1,102 nonhomozygotes with non-transfusional serum ferritin elevation at evaluation. The estimated prevalence in the Caucasian population of C282Y homozygotes with serum ferritin >900 μg/L at evaluation was 20 per 10,000 men and 4 per 10,000 women; this constellation was predictive of iron stores >4 g in men and >2 g in women. The estimated prevalence per 10,000 of non-C282Y homozygotes with serum ferritin >900 μg/L at evaluation was 7 among Caucasians, 13 among Hispanics, 20 among African Americans, and 38 among Asians and Pacific Islanders, and this constellation was predictive of iron stores >2 g but <4 g. In conclusion, serum ferritin >900 μg/L after initial elevations of both serum ferritin and transferrin saturation is predictive of mildly increased iron stores in multiple ethnic populations regardless of HFE genotype. Serum ferritin >900 μg/L in male C282Y homozygotes is predictive of moderately increased iron stores. PMID:18429050

  3. The importance of sample collection when using single cytokine levels and systemic cytokine profiles as biomarkers--a comparative study of serum versus plasma samples.

    PubMed

    Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein

    2015-03-01

    Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Boron exposure through drinking water during pregnancy and birth size.

    PubMed

    Igra, Annachiara Malin; Harari, Florencia; Lu, Ying; Casimiro, Esperanza; Vahter, Marie

    2016-10-01

    Boron is a metalloid found at highly varying concentrations in soil and water. Experimental data indicate that boron is a developmental toxicant, but the few human toxicity data available concern mostly male reproduction. To evaluate potential effects of boron exposure through drinking water on pregnancy outcomes. In a mother-child cohort in northern Argentina (n=194), 1-3 samples of serum, whole blood and urine were collected per woman during pregnancy and analyzed for boron and other elements to which exposure occurred, using inductively coupled plasma mass spectrometry. Infant weight, length and head circumference were measured at birth. Drinking water boron ranged 377-10,929μg/L. The serum boron concentrations during pregnancy ranged 0.73-605μg/L (median 133μg/L) and correlated strongly with whole-blood and urinary boron, and, to a lesser extent, with water boron. In multivariable-adjusted linear spline regression analysis (non-linear association), we found that serum boron concentrations above 80μg/L were inversely associated with birth length (B-0.69cm, 95% CI -1.4; -0.024, p=0.043, per 100μg/L increase in serum boron). The impact of boron appeared stronger when we restricted the exposure to the third trimester, when the serum boron concentrations were the highest (0.73-447μg/L). An increase in serum boron of 100μg/L in the third trimester corresponded to 0.9cm shorter and 120g lighter newborns (p=0.001 and 0.021, respectively). Considering that elevated boron concentrations in drinking water are common in many areas of the world, although more screening is warranted, our novel findings warrant additional research on early-life exposure in other populations. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Evaluation and optimization of a commercial blocking ELISA for detecting antibodies to influenza A virus for research and surveillance of mallards.

    PubMed

    Shriner, Susan A; VanDalen, Kaci K; Root, J Jeffrey; Sullivan, Heather J

    2016-02-01

    The availability of a validated commercial assay is an asset for any wildlife investigation. However, commercial products are often developed for use in livestock and are not optimized for wildlife. Consequently, it is incumbent upon researchers and managers to apply commercial products appropriately to optimize program outcomes. We tested more than 800 serum samples from mallards for antibodies to influenza A virus with the IDEXX AI MultiS-Screen Ab test to evaluate assay performance. Applying the test per manufacturer's recommendations resulted in good performance with 84% sensitivity and 100% specificity. However, performance was improved to 98% sensitivity and 98% specificity by increasing the recommended cut-off. Using this alternative threshold for identifying positive and negative samples would greatly improve sample classification, especially for field samples collected months after infection when antibody titers have waned from the initial primary immune response. Furthermore, a threshold that balances sensitivity and specificity reduces estimation bias in seroprevalence estimates. Published by Elsevier B.V.

  6. Seroepidemiology of Human Brucellosis Among Blood Donors in Southern Ethiopia: Calling Attention to a Neglected Zoonotic Disease.

    PubMed

    Workalemahu, Bereket; Sewunet, Tsegaye; Astatkie, Ayalew

    2017-01-11

    Human brucellosis is neglected in southern Ethiopia. Although traditional food processing practices and animal husbandry which increase the risk of brucellosis are common, it has not been properly studied yet. This study was conducted to determine the seroepidemiology of brucellosis among apparently healthy individuals in southern Ethiopia. In the study, blood samples were collected to screen for serum agglutinins reactive to stained antigen of Brucella abortus Standard tube titration was performed for reactive serum to determine the titer of the agglutinin. A structured questionnaire was used to collect data on possible risk factors for brucellosis. The seroprevalence of human brucellosis in this study was found to be 10.6% (95% confidence interval = 7.0, 14.0). Possession of domestic ruminant animals, contact with ruminant animals, and husbandry practices at home were associated with seropositivity. The higher seroprevalence of human brucellosis in the study area needs attention and additional confirmatory investigation. © The American Society of Tropical Medicine and Hygiene.

  7. Blood alcohol concentration measurement using a salivary reagent stick: a reliable tool for emergency departments?

    PubMed

    Phair, I C; Mardel, S; Bodiwala, G G

    1990-06-01

    Measurements of blood alcohol concentration (BAC) were made on patients who presented to an accident and emergency department with acute alcohol intoxication. A correlation of r = 0.418 was noted to exist between BAC as measured by sampling saliva and blood. Blood alcohol concentrations as measured by salivary reagent strip (ALCO-SCREEN, Chem Elec.) were significantly lower (p less than 0.0001) than those determined by gas chromatography of serum. Although such reagent strips offer a rapid measurement of BAC, it is concluded that they are unreliable for the quantitative measurement of BAC in accident and emergency departments.

  8. The impact of protease inhibitors on maternal serum screening analyte levels in pregnant women who are HIV positive.

    PubMed

    Einstein, Francine H; Wright, Rodney L; Trentacoste, Stephanie; Gross, Susan; Merkatz, Irwin R; Bernstein, Peter S

    2004-09-01

    The purpose of this study was to compare alpha-fetoprotein, human chorionic gonadotropin, and unconjugated estriol levels in women who take protease inhibitors and those women who do not. This retrospective review from August 2000 to May 2003 was performed for maternal serum screen results, medication use, pregnancy, and perinatal outcomes. Thirty-nine women met study criteria. Sixteen women were treated with protease inhibitors, and 23 women were not treated with protease inhibitors. There was no difference in initial viral load or initial CD4 count between the groups. No difference was found for human chorionic gonadotropin and estriol levels; significantly lower alpha-fetoprotein multiples of the median were found for the women who were treated with protease inhibitors compared with the women who were not (0.97 +/- 0.32 [SD] MoM vs 1.2 +/- 0.4 MoM, respectively; P = .04). Six of 39 women (15%) had positive maternal serum screens. All the babies were normal at birth, and there were no cases of perinatal transmission of human immunodeficiency virus. Protease inhibitors are associated with lower alpha-fetoprotein levels in women who are infected with human immunodeficiency virus.

  9. Reevaluating cathepsin D as a biomarker for breast cancer: serum activity levels versus histopathology.

    PubMed

    Abbott, Daniel E; Margaryan, Naira V; Jeruss, Jacqueline S; Khan, Seema; Kaklamani, Virginia; Winchester, David J; Hansen, Nora; Rademaker, Alfred; Khalkhali-Ellis, Zhila; Hendrix, Mary J C

    2010-01-01

    Cathepsin D is a lysosomal hydrolase involved in intra- and extracellular proteolysis. This enzyme is aberrantly produced and processed in malignancy, and most notably is over-secreted into the tumor cell microenvironment. This hyper-secretion may lead to excessive degradation of the extracellular matrix, and contribute to tumor progression and metastases. These phenomena have been established in vitro, and there is evidence that Cathepsin D is similarly dysregulated in human breast cancer patients. Because breast cancer lacks an effective screening or surveillance biomarker, here we address the hypothesis that serum Cathepsin D activity may be useful to assess the presence or progression of breast cancer in females. While representative histologic sections from various disease-specific cohorts confirm previous findings that increased Cathepsin D production and secretion correlate with tumor progression, we report no difference in serum Cathepsin D activity between patients who are disease free, patients with pre-invasive or limited invasive disease, and patients with metastatic disease. Furthermore, in patients with known metastatic disease, there were no clinical variables associated with significantly different serum Cathepsin D activity. However, the immunohistochemical localization of Cathepsin D expression in histopathologic sections from breast cancer patients correlates with disease progression. Based on the serum results, and in contradistinction to Cathepsin D localization in breast cancer tissues, our findings support using Cathepsin D as a reliable histopathology biomarker for disease progression, but not for serum screening.

  10. Development of a liquid chromatography-multiple reaction monitoring procedure for concurrent verification of exposure to different forms of mustard agents.

    PubMed

    Yeo, Thong-Hiang; Ho, Mer-Lin; Loke, Weng-Keong

    2008-01-01

    A novel liquid chromatography-multiple reaction monitoring (LC-MRM) procedure has been developed for retrospective diagnosis of exposure to different forms of mustard agents. This concise method is able to validate prior exposure to nitrogen mustards (HN-1, HN-2, and HN-3) or sulfur mustard (HD) in a single run, which significantly reduces analysis time compared to separate runs to screen for different mustards' biomarkers based on tandem mass spectrometry. Belonging to one of the more toxic classes of chemical warfare agents, these potent vesicants bind covalently to the cysteine-34 residue of human serum albumin. This results in the formation of stable adducts whose identities were confirmed by a de novo sequencing bioinformatics software package. Our developed technique tracks these albumin-derived adduct biomarkers in blood samples which persist in vitro following exposure, enabling a detection limit of 200 nM of HN-1, 100 nM of HN-2, 200 nM of HN-3, or 50 nM of HD in human blood. The CWA-adducts formed in blood samples can be conveniently and sensitively analyzed by this MRM technique to allow rapid and reliable screening.

  11. Association of adipokines and adhesion molecules with indicators of obesity in women undergoing mammography screening

    PubMed Central

    2012-01-01

    Background The soluble cell adhesion molecules and adipokines are elevated in patients with obesity, hypertension, type 2 diabetes mellitus, breast cancer and atherosclerosis. Objective To investigate the relationship between anthropometric profile, dietary intake, lipid profile and fasting glycemia with serum levels of adipokines (adiponectin and PAI-1) and adhesion molecules (ICAM-1 and VCAM-1) in women without breast cancer undergoing routine mammographic screening. Design Transversal study. Subjects One hundred and forty-five women over 40-years old participated in this study. Results In 39.3% of cases the BMI was above 30 kg/m2; 46.9% had hypertension, 14.5% had type 2 Diabetes Mellitus, 31.7% had dyslipidemia and 88.3% presented a waist-to-hip ratio ≥ 0.8. A linear correlation was found between serum levels of PAI-1 and triglycerides, between serum levels of PAI-1 and WHR and between serum levels of VCAM-1 and BMI. Conclusion We found a high prevalence of obesity and metabolic syndrome. PAI-1 and VCAM-1 levels were correlated with clinical indicators of obesity and overweight. PMID:23113882

  12. The association between quality of care and the intensity of diabetes disease management programs.

    PubMed

    Mangione, Carol M; Gerzoff, Robert B; Williamson, David F; Steers, W Neil; Kerr, Eve A; Brown, Arleen F; Waitzfelder, Beth E; Marrero, David G; Dudley, R Adams; Kim, Catherine; Herman, William; Thompson, Theodore J; Safford, Monika M; Selby, Joe V

    2006-07-18

    Although disease management programs are widely implemented, little is known about their effectiveness. To determine whether disease management by physician groups is associated with diabetes care processes, control of intermediate outcomes, or the amount of medication used when intermediate outcomes are above target levels. Cross-sectional study. Patients were randomly sampled from 63 physician groups nested in 7 health plans sponsored by Translating Research into Action for Diabetes (87%) and from 4 health plans with individual physician contracts (13%). 8661 adults with diabetes who completed a survey (2000-2001) and had medical record data. Physician group and health plan directors described their organizations' use of physician reminders, performance feedback, and structured care management on a survey; their responses were used to determine measures of intensity of disease management. The current study measured 8 processes of care, including most recent hemoglobin A1c level, systolic blood pressure, serum low-density lipoprotein cholesterol level, and several measures of medication use. Increased use of any of 3 disease management strategies was significantly associated with higher adjusted rates of retinal screening, nephropathy screening, foot examinations, and measurement of hemoglobin A1c levels. Serum lipid level testing and influenza vaccine administration were associated with greater use of structured care management and performance feedback. Greater use of performance feedback correlated with an increased rate of foot examinations (difference, 5 percentage points [95% CI, 1 to 8 percentage points]), and greater use of physician reminders was associated with an increased rate of nephropathy screening (difference, 15 percentage points [CI, 6 to 23 percentage points]). No strategies were associated with intermediate outcome levels or level of medication management. Physician groups were not randomly sampled from population-based listings, and disease management strategies were not randomly allocated across groups. Disease management strategies were associated with better processes of diabetes care but not with improved intermediate outcomes or level of medication management. A greater focus on direct measurement, feedback, and reporting of intermediate outcome levels or of level of medication management may enhance the effectiveness of these programs.

  13. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  14. Gastric cancer screening of a high-risk population in Japan using serum pepsinogen and barium digital radiography.

    PubMed

    Ohata, Hiroshi; Oka, Masashi; Yanaoka, Kimihiko; Shimizu, Yasuhito; Mukoubayashi, Chizu; Mugitani, Kouichi; Iwane, Masataka; Nakamura, Hideya; Tamai, Hideyuki; Arii, Kenji; Nakata, Hiroya; Yoshimura, Noriko; Takeshita, Tetsuya; Miki, Kazumasa; Mohara, Osamu; Ichinose, Masao

    2005-10-01

    With the aim of developing more efficient gastric cancer screening programs for use in Japan, we studied a new screening program that combines serum pepsinogen (PG) testing and barium digital radiography (DR). A total of 17 647 middle-aged male subjects underwent workplace screening over a 7-year period using a combination of PG testing and DR. This program's effectiveness, as well as other characteristics of the program, was analyzed. Forty-nine cases of gastric cancer were detected (comprising 88% early cancer cases). The detection rate was 0.28%, and the positive predictive value was 0.85%. The PG test detected 63.3% of cases, DR detected 69.4% of cases, and both tests were positive in 32.7% of cancer cases. The two methods were almost equally effective, and were considerably more effective than conventional screening using photofluorography. Each screening method detected a distinct gastric cancer subgroup; the PG test efficiently detected asymptomatic small early cancer with intestinal type histology, while DR was efficient at detecting cancers with depressed or ulcerated morphology and diffuse type histology. The cost for the detection of a single cancer was much less than that for conventional screening. In fact, it is possible to further reduce the cost of detecting a single cancer to a cost comparable to that of surgically resecting a single gastric cancer. Thus, it is probable that a highly efficient gastric cancer screening system can be implemented by combining the two screening methods. Such a screening program would be beneficial in a population at high risk for gastric cancer.

  15. Epidemiology of foot-and-mouth disease in Landhi Dairy Colony, Pakistan, the world largest Buffalo colony

    PubMed Central

    Klein, Joern; Hussain, Manzoor; Ahmad, Munir; Afzal, Muhammad; Alexandersen, Soren

    2008-01-01

    Background Foot-and-mouth disease (FMD) is endemic in Pakistan and causes huge economic losses. This work focus on the Landhi Dairy Colony (LDC), located in the suburbs of Karachi. LDC is the largest Buffalo colony in the world, with more than 300,000 animals (around 95% buffaloes and 5% cattle, as well as an unknown number of sheep and goats). Each month from April 2006 to April 2007 we collected mouth-swabs from apparently healthy buffaloes and cattle, applying a convenient sampling based on a two-stage random sampling scheme, in conjunction with participatory information from each selected farm. Furthermore, we also collected epithelium samples from animals with clinical disease, as well as mouth-swabs samples from those farms. In addition, we analysed a total of 180 serum samples randomly collecting 30 samples each month at the local slaughterhouse, from October 2006 to March 2007. Samples have been screened for FMDV by real-time RT-PCR and the partial or full 1D coding region of selected isolates has been sequenced. Serum samples have been analysed by applying serotype-specific antibody ELISA and non-structural proteins (NSP) antibody ELISA. Results FMDV infection prevalence at aggregate level shows an endemic occurrence of FMDV in the colony, with peaks in August 2006, December 2006 and February 2007 to March 2007. A significant association of prevalence peaks to the rainy seasons, which includes the coldest time of the year and the muslimic Eid-festival, has been demonstrated. Participatory information indicated that 88% of all questioned farmers vaccinate their animals. Analysis of the serum samples showed high levels of antibodies for serotypes O, A, Asia 1 and C. The median endpoint-titre for all tested serotypes, except serotype C, in VNT titration is at a serum dilution of equal or above 1/100. All 180 serum samples collected have been tested for antibodies against the non-structural proteins and all but four have been found positive. Out of the 106 swab-samples from apparently healthy and affected animals positive in real-time RT-PCR, we sequenced the partial or full 1D coding region from 58 samples. In addition we sequenced the full 1D coding region of 17 epithelium samples from animals with clinical signs of FMD. From all sequenced samples, swabs and epithelium, 19 belong to the regional PanAsia II lineage of serotype O and 56 to the A/Iran/2005 lineage of serotype A. Conclusion For an effective and realisable FMD control program in LDC, we suggest to introduce a twice annually mass vaccination of all buffaloes and cattle in the colony. These mass vaccinations should optimally take place shortly before the beginning of the two rainy periods, e.g. in June and September. Those vaccinations should, in our opinion, be in addition to the already individually performed vaccinations of single animals, as the latter usually targets only newly introduced animals. This suggested combination of mass vaccination of all large ruminants with the already performed individually vaccination should provide a continuous high level of herd immunity in the entire colony. Vaccines used for this purpose should contain the matching vaccine strains, i.e. as our results indicate antigens for A/Iran/2005 and the regional type of serotype O (PanAsia II), but also antigens of the, in this world region endemic, Asia 1 lineage should be included. In the long term it will be important to control the vaccine use, so that subclinical FMD will be avoided. PMID:18445264

  16. Effect of delayed serum separation and storage temperature on serum glucose concentration in horse, dog, alpaca, and sturgeon.

    PubMed

    Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey

    2015-03-01

    Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.

  17. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xinsheng, E-mail: xzhang@iavi.org; Molecular and Cellular Biology Program, State University of New York, Brooklyn, NY; Wallace, Olivia L.

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions,more » which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance.« less

  18. Changes to Serum Sample Tube and Processing Methodology Does Not Cause Inter-Individual Variation in Automated Whole Serum N-Glycan Profiling in Health and Disease

    PubMed Central

    Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.

    2015-01-01

    Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126

  19. Changes to serum sample tube and processing methodology does not cause Intra-Individual [corrected] variation in automated whole serum N-glycan profiling in health and disease.

    PubMed

    Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R

    2015-01-01

    Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.

  20. Male Oncology Research and Education program for men at high risk for prostate cancer.

    PubMed

    Lorentz, J; Liu, S K; Vesprini, D

    2018-04-01

    Three groups of men are at high risk of developing prostate cancer: men with a strong family history of prostate cancer, men of West African or Caribbean ancestry, and men with a germline pathogenic variant in a prostate cancer-associated gene. Despite the fact that those men constitute a significant portion of the male population in North America, few recommendations for prostate cancer screening specific to them have been developed. For men at general population risk for prostate cancer, screening based on prostate-specific antigen (psa) has remained controversial despite the abundance of literature on the topic. As a result, recommendations made by major screening authorities are inconsistent (ranging from no psa screening to baseline psa screening at age 45), allowing physicians to pick and choose how to screen their patients. The Male Oncology Research and Education (more) program is an observational research program that serves as an academic platform for multiple research foci. For its participants, serum and dna are biobanked, medical information is collected, and contact for relevant research-related opportunities is maintained. This research program is paired with a specialized clinic called the more clinic, where men at high risk are regularly screened for prostate cancer in a standard approach that includes physical examination and serum psa measurement. In this article, we describe the goals, participant accrual to date, and projects specific to this unique program.

  1. Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.

    PubMed

    Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H

    2013-10-01

    Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Iron Plays a Certain Role in Patterned Hair Loss

    PubMed Central

    Park, Song Youn; Na, Se Young; Kim, Jun Hwan; Cho, Soyun

    2013-01-01

    Role of iron in hair loss is not clear yet. The purpose of this study was to evaluate the relationship between iron and hair loss. Retrospective chart review was conducted on patients with female pattern hair loss (FPHL) and male pattern hair loss (MPHL). All patients underwent screening including serum ferritin, iron, and total iron binding capacity (TIBC), CBC, ESR and thyroid function test. For normal healthy controls, age-sex matched subjects who had visited the hospital for a check-up with no serious disease were selected. A total 210 patients with FPHL (n = 113) and MPHL (n = 97) with 210 healthy controls were analyzed. Serum ferritin concentration (FC) was lower in patients with FPHL (49.27 ± 55.8 µg/L), compared with normal healthy women (77.89 ± 48.32 µg/L) (P < 0.001). Premenopausal FPHL patients turned out to show much lower serum ferritin than age/sex-matched controls (P < 0.001). Among MPHL patients, 22.7% of them showed serum FC lower than 70 µg/L, while no one had serum FC lower 70 µg/L in healthy age matched males. These results suggest that iron may play a certain role especially in premenopausal FPHL. The initial screening of iron status could be of help for hair loss patients. PMID:23772161

  3. Iron plays a certain role in patterned hair loss.

    PubMed

    Park, Song Youn; Na, Se Young; Kim, Jun Hwan; Cho, Soyun; Lee, Jong Hee

    2013-06-01

    Role of iron in hair loss is not clear yet. The purpose of this study was to evaluate the relationship between iron and hair loss. Retrospective chart review was conducted on patients with female pattern hair loss (FPHL) and male pattern hair loss (MPHL). All patients underwent screening including serum ferritin, iron, and total iron binding capacity (TIBC), CBC, ESR and thyroid function test. For normal healthy controls, age-sex matched subjects who had visited the hospital for a check-up with no serious disease were selected. A total 210 patients with FPHL (n = 113) and MPHL (n = 97) with 210 healthy controls were analyzed. Serum ferritin concentration (FC) was lower in patients with FPHL (49.27 ± 55.8 µg/L), compared with normal healthy women (77.89 ± 48.32 µg/L) (P < 0.001). Premenopausal FPHL patients turned out to show much lower serum ferritin than age/sex-matched controls (P < 0.001). Among MPHL patients, 22.7% of them showed serum FC lower than 70 µg/L, while no one had serum FC lower 70 µg/L in healthy age matched males. These results suggest that iron may play a certain role especially in premenopausal FPHL. The initial screening of iron status could be of help for hair loss patients.

  4. Indication of prenatal diagnosis in pregnancies complicated by undetectable second-trimester maternal serum estriol levels.

    PubMed

    Minsart, Anne-Frédérique; Van Onderbergen, Anne; Jacques, Francotte; Kurt, Crener; Gillerot, Yves

    2008-07-01

    Undetectable maternal serum unconjugated estriol levels in the second-trimester screening test have been associated with congenital pathology and an adverse pregnancy outcome. We reviewed outcomes of pregnancies with undetectable levels of estriol (<0.25 ng/ml) in the triple-marker screening test and assessed the clinical value of this finding. We studied estriol values in 6,018 pregnant patients who underwent a triple-marker screening test during a seven-year period. 26 women had estriol levels at or below the sensitivity of the assay. The most common explanations were dating errors, prematurity, growth restriction and X-linked ichthyosis. We also observed one fetal death at 16 weeks, one severe threatened fetal abortion, one case of multiple congenital anomalies and one case of isolated adrenocorticotropin hormone deficiency. There were 6 women remaining with unexplained undetectable estriol. Undetectable maternal estriol values may indicate a severe fetal pathology and should lead to further investigations.

  5. Comparison of Schmallenberg virus antibody levels detected in milk and serum from individual cows.

    PubMed

    Daly, Janet M; King, Barnabas; Tarlinton, Rachael A; Gough, Kevin C; Maddison, Ben C; Blowey, Roger

    2015-03-11

    Schmallenberg virus (SBV) is a recently emerged virus of ruminants in Europe. Enzyme-linked immunosorbent assays (ELISA) are commonly used to detect SBV-specific antibodies in bulk tank milk samples to monitor herd exposure to infection. However, it has previously been shown that a bulk tank milk sample can test positive even though the majority of cows within the herd are seronegative for SBV antibodies. Development of a pen-side test to detect antibodies in individual milk samples would potentially provide a cheaper test (for which samples are obtained non-invasively) than testing individual serum samples by ELISA. Therefore, the aim of this study was to investigate the agreement between antibody levels measured in milk and serum. Corresponding milk and serum samples from 88 cows in two dairy herds in the UK were tested for presence of immunoglobulin G antibodies to SBV using a commercially-available indirect ELISA. A serum neutralisation test (NT) was also performed as a gold standard assay. The ELISA values obtained for the bulk tank milk samples corresponded with the mean values for individual milk samples from each herd (bulk tank milk values were 58% and 73% and mean individual milk values 50% and 63% for herds A and B, respectively). Of the 88 serum samples tested in the NT, 82 (93%) were positive. Although at higher antibody levels, the ELISA values tended to be higher for the individual milk samples than for the corresponding serum samples, the positive predictive value for milk samples was 98% and for serum samples 94%. The serum ELISA was more likely to give false positive results around the lower cut-off value of the assay. The results indicate that testing of individual milk samples for antibodies against SBV by ELISA could be used to inform decisions in the management of dairy herds such as which, if any, animals to vaccinate.

  6. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  7. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes

    PubMed Central

    Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723

  8. Severe hyperkalemia following adrenalectomy for aldosteronoma: prediction, pathogenesis and approach to clinical management- a case series.

    PubMed

    Tahir, A; McLaughlin, K; Kline, G

    2016-07-27

    As the field of Primary Aldosteronism (PA) becomes ever expanded, diagnosis of PA is increasingly diagnosed by endocrinologists. With increased PA screening, many of the cases are now found in patients with complex co-morbidities in addition to their hypertension. Post adrenalectomy renal impairment with hyperkalemia is now increasingly seen in these complex patients, as evidenced by the numerous reports on this issue that have appeared within the past 3 years. We present a small case series to illustrate the breadth of the problem, along with a discussion about how such CKD/hyperkalemic events may be predicted. We present three cases of primary aldosteronism with long standing hypertension (more than 10 years) hypokalemia (2.0-3.0 mmol/l). Serum aldosterone was high with low renin activity leading to high aldosterone to renin ratio (ARR). They underwent abdominal CT scan revealing adrenal mass and adrenal vein sample confirmed lateralization. None of the patients had evidence of renal disease before surgery (as evident by normal eGFR and serum creatinine). Post adrenalectomy they had reduction in the blood pressure and became eukalemic. Serum aldosterone and renin activity were low leading to a low ARR. Case 1 developed hyperkalemia and increased serum creatinine 6 weeks post operatively which resolved with initiation of fludrocortisone and every attempt to discontinue fludrocortisone resulted in hyperkalemia and rising creatinine. Her hyperkalemia is under control with oral sodium bicarbonate. Case 2 developed hyperkalemia and increasing creatinine 2 months post operatively transiently requiring fludrocortisone and later on managed with furosemide for hyperkalemia. Case 3 developed renal impairment and hyperkalemia 2 weeks post operatively requiring fludrocortisone. Post APA resection severe hyperkalemia may be a common entity and screening should be actively considered in high risk patients. Older age, longer duration of hypertension, impaired pre-op and post-op GFR and higher levels of pre-op aldosterone and are all risk factors which predict the likelihood of developing post-operative hyperkalemia. Fludrocortisone, sodium bicarbonate, loop diuretics and potassium binders can be used for treatment. Treatment choice should be tailored to patient characteristics including fluid status, blood pressure and serum creatinine. Potassium binders should be avoided in patients with history of recent abdominal surgery, opioid use and constipation. Serum electrolytes and creatinine should be monitored every 1-2 weeks after starting treatment to ensure an adequate response. Prolonged management may be necessary in some cases and at-risk patients should be counselled as to the meaning and importance of post-operative changes in measured renal function and potassium.

  9. Quantitative polymerase chain reaction detection of circulating DNA in serum for early diagnosis of mucormycosis in immunocompromised patients.

    PubMed

    Millon, Laurence; Larosa, Fabrice; Lepiller, Quentin; Legrand, Faezeh; Rocchi, Steffi; Daguindau, Etienne; Scherer, Emeline; Bellanger, Anne-Pauline; Leroy, Joel; Grenouillet, Frederic

    2013-05-01

    The aim of our study was to assess the detection of circulating DNA from the most common species of Mucorales for early diagnosis of mucormycosis in at-risk patients. We retrospectively evaluated a combination of 3 quantitative polymerase chain reaction (qPCR) assays using hydrolysis probes targeting Mucor/Rhizopus, Lichtheimia (formerly Absidia), and Rhizomucor for circulating Mucorales detection. Serial serum samples from 10 patients diagnosed with proven mucormycosis (2-9 samples per patient) were analyzed. No cross-reactivity was detected in the 3 qPCR assays using 19 reference strains of opportunistic fungi, and the limit of detection ranged from 3.7 to 15 femtograms/10 µL, depending on the species. DNA from Mucorales was detected in the serum of 9 of 10 patients between 68 and 3 days before mucormycosis diagnosis was confirmed by histopathological examination and/or positive culture. All the qPCR results were concordant with culture and/or PCR-based identification of the causing agents in tissue (Lichtheimia species, Rhizomucor species, and Mucor/Rhizopus species in 4, 3, and 2 patients, respectively). Quantitative PCR was negative in only 1 patient with proven disseminated mucormycosis caused by Lichtheimia species. Our study suggests that using specific qPCR targeting several species of Mucorales according to local ecology to screen at-risk patients could be useful in a clinical setting. The cost and efficacy of this strategy should be evaluated. However, given the human and economic cost of mucormycosis and the need for rapid diagnosis to initiate prompt directed antifungal therapy, this strategy could be highly attractive.

  10. Classification of oral cancers using Raman spectroscopy of serum

    NASA Astrophysics Data System (ADS)

    Sahu, Aditi; Talathi, Sneha; Sawant, Sharada; Krishna, C. Murali

    2014-03-01

    Oral cancers are the sixth most common malignancy worldwide, with low 5-year disease free survival rates, attributable to late detection due to lack of reliable screening modalities. Our in vivo Raman spectroscopy studies have demonstrated classification of normal and tumor as well as cancer field effects (CFE), the earliest events in oral cancers. In view of limitations such as requirement of on-site instrumentation and stringent experimental conditions of this approach, feasibility of classification of normal and cancer using serum was explored using 532 nm excitation. In this study, strong resonance features of β-carotenes, present differentially in normal and pathological conditions, were observed. In the present study, Raman spectra of sera of 36 buccal mucosa, 33 tongue cancers and 17 healthy subjects were recorded using Raman microprobe coupled with 40X objective using 785 nm excitation, a known source of excitation for biomedical applications. To eliminate heterogeneity, average of 3 spectra recorded from each sample was subjected to PC-LDA followed by leave-one-out-cross-validation. Findings indicate average classification efficiency of ~70% for normal and cancer. Buccal mucosa and tongue cancer serum could also be classified with an efficiency of ~68%. Of the two cancers, buccal mucosa cancer and normal could be classified with a higher efficiency. Findings of the study are quite comparable to that of our earlier study, which suggest that there exist significant differences, other than β- carotenes, between normal and cancerous samples which can be exploited for the classification. Prospectively, extensive validation studies will be undertaken to confirm the findings.

  11. Repeatability and accuracy of reproductive tract scoring to determine pubertal status in beef heifers.

    PubMed

    Rosenkrans, Kelly S; Hardin, David K

    2003-03-01

    The objective of this study was to compare the repeatability and accuracy of palpation per rectum to transrectal ultrasonography and serum progesterone concentrations for determining pubertal status in beef heifers. One hundred and seventy-four rectal examinations were performed on 29 predominantly Angus heifers by two veterinarians (A and B) and assigned individual reproductive tract scores (RTS) during monthly examinations over a 3-month period. Heifers were examined in the morning by both veterinarians, randomized, and re-examined in the afternoon. The size and location of ovarian structures of each heifer were determined by ultrasonography. Heifers with follicles >10mm in diameter or corpora lutea were classified as pubertal. Serum progesterone concentrations at the time of the examination and 10 days later were determined by radioimmunoassay and used to classify heifers as prepubertal (<1 ng/ml in both samples) or pubertal (at least one sample >or=1 ng/ml). Kappa, which describes degree of agreement beyond chance, was used to determine repeatability of the RTS system. Multicategory Kappa for agreement was 0.64 within veterinarian, 0.46 between veterinarian, and 0.35 between palpation per rectum and transrectal ultrasonography. Sensitivity and specificity of palpation per rectum for diagnosis of pubertal status compared to serum progesterone levels were higher (82 and 69%, respectively) than sensitivity and specificity of ultrasonography (79 and 59%, respectively). This study validates the RTS system as a repeatable and accurate screening test to evaluate pubertal status in groups of heifers prior to the onset of the breeding season.

  12. [The importance of using a test to detect Chlamydia trachomatis infection in patients undergoing counseling and testing for sexually transmitted diseases at a public health center].

    PubMed

    Hatori, Toru; Nakamura, Tamiko; Tsukui, Satoshi

    2013-01-01

    Serum levels of antibody against Chlamydia trachomatis are used routinely to diagnose chlamydial infection among patients undergoing counseling and testing for sexually transmitted disease at public health centers in Japan, whereas tests for pathogen detection are conducted at most clinics. The objective of the present study was to evaluate the usefulness of a test for detecting C. trachomatis and to compare it with that of screening for serum chlamydia antibodies at a public health center. Serum chlamydia antibody titers were estimated using an ELISA, while C. trachomatis was detected in the urine using the nucleic acid amplification assay that included strand displacement amplification (SDA). We compared the results of 120 patients (64 men and 56 women), because the sensitivity of the method using urine samples from women has been reported to be as high as that using cervical samples. The serum antibody test results were considered to be positive when either one or both of the IgA and IgG antibodies were positive. The overall prevalence of positive results for the antibody test was 24.2% (14.1% for men and 35.7% for women), and that for the SDA method was 7.5% (3.1% for men and 12.5% for women). The concordance rate of the 2 tests was 81.7%, with a kappa statistic of 0.35 (95% CI, 0.10-0.59). Of the 9 subjects who were positive for C. trachomatis using the SDA assay, 1 had serum chlamydia IgA antibodies, 6 had IgG antibodies, 1 had both the antibodies, and 1 had no antibodies. On the other hand, of the 111 subjects who were negative for C. trachomatis, only 8 had chlamydia IgA antibodies, 5 had IgG antibodies, and 8 had both the antibodies. These results indicated there was no association between serum IgA antibodies and the presence of C. trachomatis. The presence of serum chlamydia antibodies was significantly higher in subjects with a past history of genital chlamydial infection than in those without a past history of infection (P<0.01). However, there was no difference in the results of the SDA assay between subjects with or without a previous infection. Thus, although serum chlamydia antibodies are generally measured at public health centers, tests for detecting C. trachomatis should also be used.

  13. Correlation analysis of two serum-specific immunoglobulin E test systems and skin-prick test in allergic rhinitis patients from northeast China.

    PubMed

    Jiang, Xiao-Dan; Li, Guang-Yu; Dong, Zhen; Zhu, Dong-Dong

    2011-01-01

    Skin-prick testing (SPT) is the most common screening method for allergy evaluation. The detection of serum-specific immunoglobulin E (sIgE) is also commonly used. The sensitivity and specificity of these testing methods may vary due to type of causative allergen and type of allergic manifestation. The purpose of this study was to evaluate the correlation between two methods of measuring sIgE (AllergyScreen [Mediwiss Analytic GmbH, Moers, Germany] and ImmunoCAP [Pharmacia, Uppsala, Sweden]) and SPT for the diagnosis of allergic rhinitis (AR). All 216 patients who were referred to the allergist for suspected AR from June to October 2009 had SPT and the two serological tests. One hundred fifty-eight patients had a positive clinical history and a related positive SPT. The SPT was used as reference standard, and we selected three allergens (Dermatophagoides pteronyssinus, mugwort, and ragweed), which were common in fall in northeast China, to analyze the correlation of the two serum tests and SPT. Compared with the SPT, the diagnostic indexes (accuracy, sensitivity and specificity) of the AllergyScreen system and the ImmunoCAP system were 0.819 versus 0.810, 0.780 versus 0.872, and 0.862 versus 0.741, respectively. The accuracy was similar between the two systems (p > 0.05). The ImmunoCAP system method had a higher sensitivity (p < 0.01). The AllergyScreen system had a higher specificity (p < 0.01). These data support that the AllergyScreen system and ImmunoCAP system can identify potentially significant allergens in the diagnosis of AR in patients from northeastern China.

  14. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    PubMed

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.

  15. Comorbid post-traumatic stress disorder in alcohol use disorder: relationships to demography, drinking and neuroimmune profile.

    PubMed

    Neupane, Sudan Prasad; Bramness, Jørgen G; Lien, Lars

    2017-08-29

    This study examined how alcohol use disorder (AUD) patients with post-traumatic stress disorder (PTSD) differed from those without PTSD in terms of demography, drinking patterns and C-reactive protein, inflammatory cytokines, tryptophan metabolism parameters, and brain-derived neurotrophic factor (BDNF). A consecutive sample (N = 187) of treatment-receiving AUD individuals were recruited from Nepalese facilities. They underwent fully structured psychiatric interviews. Serum levels of inflammatory cytokines [interleukin (IL)-6, IL-1 Receptor antagonist (IL-1Ra), IL-10, tumor necrosis factor-alpha (TNF-α), and interferon-gamma (IFN-γ)] were determined by a multiplex assay, kynurenine and tryptophan levels by high-performance liquid chromatography, and BDNF by enzyme-linked immunosorbent assay (ELISA). The prevalence of exposure to severe trauma and PTSD was 74% and 17%, respectively. PTSD comorbidity was not associated with age, gender, or socioeconomic status, but with co-occurring major depression, history of attempted suicide, earlier peak of drinking problems, higher drinking quantity and withdrawal symptoms, experiencing alcoholic blackouts, and drinking problems among parents. None of the assessed neuroimmune parameters was related to comorbid PTSD. The findings support routine trauma screening in AUD treatment samples and screening for risky drinking in trauma populations to help guide interventions. The expected aberrations in neuroimmune functioning may not be found when examined in a sample with multiple psychiatric morbidities.

  16. Expression and Clinical Significance of Serum Dipeptidyl Peptidase IV Chronic Obstructive Pulmonary Disease.

    PubMed

    Chang, Xiao-Yue; Yang, Yong; Jia, Xiao-Qing; Wang, Yuan; Peng, Li-Na; Ai, Xiao-Hong; Jiang, Cui-Ying; Guo, Jian-Hua; Wu, Ting-Ting

    2016-03-01

    The purpose of this study is to explore the correlation between serum dipeptidyl peptidase IV (DPPIV) and chronic obstructive pulmonary disease (COPD) at its various disease states, analyze its applications in the prediction and diagnosis of COPD and test the possibility of DPPIV as the serologic marker for COPD screening. Samples from 74 patients (42 cases with acute exacerbation of COPD or acute exacerbation COPD (AECOPD) and 32 cases with stable COPD) and 29 control subjects were collected in this study. Those patients with AECOPD were classified as COPD remission group if their clinical symptoms relieved after nonintravenous or oral hormone therapy for 7 ± 3 days. DPPIV concentration was measured by enzyme-linked immunosorbent assay, and the difference in serum concentration of DPPIV was compared among different groups. The correlation between DPPIV concentration and age, sex or smoking history was analyzed, and the diagnostic value of DPPIV was evaluated by receiver-operating characteristic (ROC) curve analysis. Serum DPPIV concentration was significantly lower in all COPD groups as compared with that in healthy control group (P < 0.001). Serum DPPIV concentration in AECOPD group was increased after treatment (P < 0.001). There was no significant correlation between DPPIV concentration and age, sex or smoking history (P > 0.05). ROC analysis indicated that serum DPPIV concentration in all groups showed a good diagnostic accuracy, especially in stable COPD and AECOPD groups. The area under the ROC curve values were 0.901 and 0.906, respectively, with a high specificity of 0.931 for both groups and a high sensitivity of 0.75 for stable COPD and 0.875 for AECOPD. Serum DPPIV concentration in patients with COPD is decreased significantly, and there is no correlation between serum DPPIV concentration and sex or age. Serum DPPIV not only is an independent predictive factor, but also of high value as a good serologic marker for the diagnosis of COPD. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  17. Direct and rapid mass spectral fingerprinting of maternal urine for the detection of Down syndrome pregnancy.

    PubMed

    Iles, Ray K; Shahpari, Maryam E; Cuckle, Howard; Butler, Stephen A

    2015-01-01

    The established methods of antenatal screening for Down syndrome are based on immunoassay for a panel of maternal serum biomarkers together with ultrasound measures. Recently, genetic analysis of maternal plasma cell free (cf) DNA has begun to be used but has a number of limitations including excessive turn-around time and cost. We aimed to develop an alternative method based on urinalysis that is simple, affordable and accurate. 101 maternal urine samples sampled at 12-17 weeks gestation were taken from an archival collection of 2567 spot urines collected from women attending a prenatal screening clinic. 18 pregnancies in this set subsequently proved to be Down pregnancies. Samples were either neat urine or diluted between 10 to 1000 fold in dH2O and subjected to matrix assisted laser desorption ionization (MALDI), time of flight (ToF) mass spectrometry (MS). Data profiles were examined in the region 6,000 to 14,000 m/z. Spectral data was normalised and quantitative characteristics of the profile were compared between Down and controls. In Down cases there were additional spectral profile peaks at 11,000-12,000 m/z and a corresponding reduction in intensity at 6,000-8,000 m/z. The ratio of the normalised values at these two ranges completely separated the 8 Down syndrome from the 39 controls at 12-14 weeks. Discrimination was poorer at 15-17 weeks where 3 of the 10 Down syndrome cases had values within the normal range. Direct MALDI ToF mass spectral profiling of maternal urinary has the potential for an affordable, simple, accurate and rapid alternative to current Down syndrome screening protocols.

  18. A study to establish whether food-based approaches can improve serum iron levels in child-bearing aged women.

    PubMed

    Bokhari, F; Derbyshire, E; Li, W; Brennan, C S; Stojceska, V

    2012-02-01

    Iron-deficiency anaemia is particularly prevalent in pregnancy. The present study aimed to determine whether functional bread containing teff flour (i.e. naturally rich in iron) could be an alternative way of improving iron status. However, before testing whether its consumption can improve pregnancy iron status, the bio-availability of iron was determined in a sample of nonpregnant women. Fifty-eight women (20-50 years) were recruited from the University. Blood samples were taken at baseline to assess iron status and participants were screened to account for other factors affecting iron status. Twenty-four participants (haemoglobin 9.5-14.0g dL(-1) ) were recruited to take part in the intervention and allocated to five groups: (i) control bread (CB); (ii) teff bread (TB); (iii) TB+level 1 phytase (TB+P1); (iv) TB+level 2 phytase (TB+P2); or (v) a supplement containing 10 mg of ferrous sulphate. Venous blood samples were taken before the intervention and after 180-210min, aiming to determine changes in serum iron. Consuming three or four slices of TB provided statistically significantly more iron (7.6mg) than CB (5.1mg) (P<0.001). Because participants were fasted, serum iron levels declined in all bread groups (average -1.5μm), although the smallest reduction was observed in the TB+P2 group (-0.3 μm). The area-under-the-curve from baseline to 210min was lower in the TB+P2 (-78.8μmol min L(-1) ) group compared to the other bread interventions, indicating higher levels of iron absorption in this group. The results obtained in the present study show that TB consumption may help to maintain serum iron levels, especially when phytase is added. The findings from the study also demonstrate there may be potential to further improve the bio-availability of iron from non-haem food sources. © 2011 Manchester Metropolitan University. Journal of Human Nutrition and Dietetics © 2011 The British Dietetic Association Ltd.

  19. Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.

    PubMed

    Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M

    2009-02-01

    Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (P<0.0001). IFAT and ELISA highly concurred in their detection of specific S. stercoralis IgA and IgG antibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.

  20. Facile fabrication of CdSe/CdS quantum dots and their application on the screening of colorectal cancer

    NASA Astrophysics Data System (ADS)

    Cao, Hongfeng; Dong, Quanjin; Hu, Li; Tu, Shiliang; Chai, Rui; Dai, Qiaoqiong

    2015-11-01

    In this paper, a facile aqueous route to water-soluble CdSe/CdS quantum dots (QDs) under mild conditions has been developed. The samples were characterized by means of transmission electron microscopy, energy-dispersive X-ray spectroscopy, and photoluminescence (PL) spectroscopy. The PL property of the QDs can be controlled by adjusting the reaction time. The CdSe/CdS QDs after 48-h reaction with size of 5 nm have the strongest PL intensity located at 553 nm, and the highest quantum yield of 19.9 %. The obtained QDs were applied for the colorectal cancer screening. The QDs could be conjugated with antibody of aldo-keto reductase family 1, member B10 (AKR1B10) for the detection of AKR1B10. The AKR1B10 in PBS/5 % serum solution with concentration of 1 ng/mL could be well calibrated, and the limit of detection could be lower than 0.05 ng/mL.

  1. Diagnosis of schistosomiasis japonica with interfacial co-assembly-based multi-channel electrochemical immunosensor arrays

    NASA Astrophysics Data System (ADS)

    Deng, Wangping; Xu, Bin; Hu, Haiyan; Li, Jianyong; Hu, Wei; Song, Shiping; Feng, Zheng; Fan, Chunhai

    2013-05-01

    Schistosomiasis control remains to be an important and challenging task in the world. However, lack of quick, simple, sensitive and specific sero-diagnostic test is still a hurdle in the control practice. The commonly employed enzyme-linked immuno-sorbent assay (ELISA) relies on the native soluble egg antigen (SEA) that is limited in supply. Here we developed an electrochemical immunosensor array (ECISA) assay with an interfacial co-assembly strategy. A recombinant Schistosoma japonicum (Sj) calcium-binding protein (SjE16) was used as a principal antigen, while the SEA as a minor, co-assembling agent, with a ratio of 8:1 (SjE16: SEA, Sj16EA), which was co-immobilized on a disposable 16-channel screen-printed carbon electrode array. A portable electrochemical detector was employed to detect antibodies in serum samples. The sensitivity of ECISA reached 100% with minimal cross-reactions. Therefore, we have demonstrated that this rapid, sensitive and specific ECISA technique has the potential to perform large-scale on-site screening of Sj infection.

  2. Pre-clinical validation study of a miniaturized electrochemical immunoassay based on square wave voltammetry for early detection of carcinoembryonic antigen in human serum.

    PubMed

    Martínez-Mancera, Flavio Dolores; García-López, Patricia; Hernández-López, José Luis

    2015-04-15

    The ELISA format for measuring carcinoembryonic antigen (CEA) serves as a reference standard against which other assays are compared. Because the World Health Organization (WHO) increasingly recommends the use of serum CEA as a diagnostic tool for cancer, it is relevant to explore the reliability of the new decentralized CEA point-of-care-testing (POCT) technologies that are available to physicians and patients, in compliance with mandates of the clinical laboratories' regulatory agencies. Electrochemical immunoassay (ECIA) based on trace lead (Pb) analysis by anodic stripping techniques using sandwich-type immunocomplex conjugates: (MB)Ab/AgCEA/Ab(PbS), and a commercial ELISA test system with optical transmission. The ECIA provides better analytical performance than does the ELISA. The within assay precision coefficient of variance (%CVw) of the ECIA is lower than the value recommended by the Hong Kong Association of Medical Laboratories (HKAML), and the recoveries of CEA at 1.0, 5.0, 10.0, 25.0 and 50.0 ng/ml are in the range of 99-110% for control serum samples. The ECIA showed a minimal positive bias of 0.0267 ± 0.3270 ng/ml (P=0.9389). The proposed CEA screening technology can be practically employed for decentralized clinical analysis of CEA in human serum. Therefore, it can be viewed as a control method for personalized therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Diagnostic and prognostic significance of neurofilament light chain NF-L, but not progranulin and S100B, in the course of amyotrophic lateral sclerosis: Data from the German MND-net.

    PubMed

    Steinacker, Petra; Huss, André; Mayer, Benjamin; Grehl, Torsten; Grosskreutz, Julian; Borck, Guntram; Kuhle, Jens; Lulé, Dorothée; Meyer, Thomas; Oeckl, Patrick; Petri, Susanne; Weishaupt, Jochen; Ludolph, Albert C; Otto, Markus

    2017-02-01

    There is a need for diagnostic, prognostic, and monitoring blood biomarkers for ALS. We aimed to analyse and compare proposed candidate markers for disease progression in the course of ALS. Blood samples were taken from 125 ALS patients, including nine patients with C9orf72 or SOD1 mutation, at regular intervals of six months. ALS patients were characterized by the ALS functional rating scale (ALSFRS-R) and the Edinburgh Cognitive and Behavioural ALS Screen (ECAS). We quantified neurofilament light chain (NF-L), S100B, and progranulin (PGRN) and analysed it in relation to disease progression. Results showed that, at baseline, serum concentrations of NF-L but not PGRN or S100B discriminated significantly between ALS and controls. Within 24 months follow-up the marker concentrations remained stable. Baseline serum NF-L levels correlated with survival time, which was confirmed in subgroups with fast, intermediate, and slow disease progression and there was a weak association with disease duration. For S100B and PGRN we found an association with ALSFRS-R score changes and a trend for decreased levels in the fast progressor subgroup. In conclusion, serum NF-L in any ALS disease stage is a promising marker to support diagnosis and predict outcome, while serum PGRN and S100B are only of minor prognostic value.

  4. Prospective validation of first-trimester combined screening for trisomy 21.

    PubMed

    Kagan, K O; Etchegaray, A; Zhou, Y; Wright, D; Nicolaides, K H

    2009-07-01

    To examine the performance of the new algorithm in screening for trisomy 21 by a combination of maternal age, fetal nuchal translucency (NT) and maternal serum free beta-human chorionic gonadotropin (beta-hCG) and pregnancy-associated plasma protein-A (PAPP-A). This was a prospective screening study for trisomy 21 in singleton pregnancies at 11 + 0 to 13 + 6 weeks of gestation using an algorithm combining maternal age, fetal NT thickness based on the mixture model for the assessment of NT, and maternal serum free beta-hCG and PAPP-A based on a multiple regression model for the assessment of serum biochemistry. The NT measurements were performed by 60 operators who had obtained The Fetal Medicine Foundation certificate of competence in the 11-13-week scan. The study population consisted of 19 614 pregnancies with a normal karyotype or delivery of a phenotypically normal baby (euploid group) and 122 cases of trisomy 21. In the euploid fetuses the NT was above the previously defined 50(th), 95(th) and 99(th) centiles in 10 033 (51.2%), 618 (3.2%) and 123 (0.6%) cases and the respective values for trisomy 21 were 117 (95.9%), 94 (77.0%) and 57 (46.7%). The median fetal NT was within 0.1 mm of the expected in 47 (78.3%) of the 60 sonographers and within 0.2 mm in all. In the euploid fetuses the median free beta-hCG was 1.0 (range, 0.1-29.4) multiples of the median (MoM) and the median PAPP-A was 1.0 (range, 0.2-3.3) MoM. The median MoM values were 1.0 or close to 1.0 MoM for each subgroup of pregnancy characteristics, including gestations of 11, 12 and 13 weeks, maternal weight of < 60 kg, 60-80 kg and > 80 kg, different ethnic origins, cigarette smokers and non-smokers, natural conception and in vitro fertilization. For a false-positive rate of 3%, the detection rate of trisomy 21 in screening by maternal age and fetal NT was 81% (95% CI, 73-89%), by maternal age and maternal serum biochemistry it was 63% (95% CI, 56-72%) and by combined screening based on maternal age, fetal NT and maternal serum biochemistry it was 90% (95% CI, 84-96%). This study has validated the new risk algorithm and demonstrated that in combined screening for trisomy 21 based on maternal age, fetal NT and free beta-hCG and PAPP-A the detection rate is about 90% for a 3% false-positive rate. (c) 2009 ISUOG.

  5. Biological variability of transferrin saturation and unsaturated iron binding capacity

    PubMed Central

    Adams, PC; Reboussin, DM; Press, RD; Barton, JC; Acton, RT; Moses, GC; Leiendecker-Foster, C; McLaren, GD; Dawkins, FW; Gordeuk, VR; Lovato, L; Eckfeldt, JH

    2007-01-01

    Background Transferrin saturation is widely considered the preferred screening test for hemochromatosis. Unsaturated iron binding capacity has similar performance at lower cost. However, the within-person biological variability of both these tests may limit their ability at commonly used cut points to detect HFE C282Y homozygous patients. Methods The Hemochromatosis and Iron Overload Screening (HEIRS) Study screened 101,168 primary care participants for iron overload using tansferrin saturation, unsaturated iron binding capacity, ferritin and HFE C282Y and H63D genotyping. Transferrin saturation and unsaturated iron binding capacity were performed at initial screening and again when selected participants and controls returned for a clinical examination several months later. A missed case was defined as a C282Y homozygote who had transferrin saturation below cut point (45 % women, 50 % men) or unsaturated iron binding capacity above cut point (150 μmol/L women, 125 μmol/L men) at either the initial screening or clinical examination, or both, regardless of serum ferritin. Results There were 209 C282Y previously undiagnosed homozygotes with transferrin saturation and unsaturated iron binding capacity testing done at initial screening and clinical examination. Sixty-eight C282Y homozygotes (33%) would have been missed at these transferrin saturation cut points (19 men, 49 women, median SF 170 μg/L, first and third quartiles 50 and 474 μg/L), and 58 homozygotes (28 %) would have been missed at the unsaturated iron binding capacity cut points (20 men, 38 women, median SF 168 μg/L, quartiles 38 and 454 μg/L). There was no advantage to using fasting samples. Conclusions The within-person biological variability of transferrin saturation and unsaturated iron binding capacity limit their usefulness as an initial screening test for expressing C282Y homozygotes. PMID:17976429

  6. First and second trimester serum tests with and without first trimester ultrasound tests for Down's syndrome screening.

    PubMed

    Alldred, S Kate; Takwoingi, Yemisi; Guo, Boliang; Pennant, Mary; Deeks, Jonathan J; Neilson, James P; Alfirevic, Zarko

    2017-03-15

    Down's syndrome occurs when a person has three copies of chromosome 21 (or the specific area of chromosome 21 implicated in causing Down's syndrome) rather than two. It is the commonest congenital cause of mental disability. Non-invasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing.  Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal) and false negative screening tests (i.e. a fetus with Down's syndrome will be missed). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. To estimate and compare the accuracy of first and second trimester serum markers with and without first trimester ultrasound markers for the detection of Down's syndrome in the antenatal period, as combinations of markers. We conducted a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), Embase (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), the Database of Abstracts of Reviews of Effectiveness (the Cochrane Library 25 August 2011), MEDION (25 August 2011), the Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), the National Research Register (Archived 2007), and Health Services Research Projects in Progress database (25 August 2011). We did not apply a diagnostic test search filter. We did forward citation searching in ISI citation indices, Google Scholar and PubMed 'related articles'. We also searched reference lists of retrieved articles SELECTION CRITERIA: Studies evaluating tests of combining first and second trimester maternal serum markers in women up to 24 weeks of gestation for Down's syndrome, with or without first trimester ultrasound markers, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. Data were extracted as test positive/test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS criteria. We used hierarchical summary ROC meta-analytical methods to analyse test performance and compare test accuracy. Analysis of studies allowing direct comparison between tests was undertaken. We investigated the impact of maternal age on test performance in subgroup analyses. Twenty-two studies (reported in 25 publications) involving 228,615 pregnancies (including 1067 with Down's syndrome) were included. Studies were generally high quality, although differential verification was common with invasive testing of only high risk pregnancies. Ten studies made direct comparisons between tests. Thirty-two different test combinations were evaluated formed from combinations of eight different tests and maternal age; first trimester nuchal translucency (NT) and the serum markers AFP, uE3, total hCG, free βhCG, Inhibin A, PAPP-A and ADAM 12. We looked at tests combining first and second trimester markers with or without ultrasound as complete tests, and we also examined stepwise and contingent strategies.Meta-analysis of the six most frequently evaluated test combinations showed that a test strategy involving maternal age and a combination of first trimester NT and PAPP-A, and second trimester total hCG, uE3, AFP and Inhibin A significantly outperformed other test combinations that involved only one serum marker or NT in the first trimester, detecting about nine out of every 10 Down's syndrome pregnancies at a 5% false positive rate. However, the evidence was limited in terms of the number of studies evaluating this strategy, and we therefore cannot recommend one single screening strategy. Tests involving first trimester ultrasound with first and second trimester serum markers in combination with maternal age are significantly better than those without ultrasound, or those evaluating first trimester ultrasound in combination with second trimester serum markers, without first trimester serum markers. We cannot make recommendations about a specific strategy on the basis of the small number of studies available.

  7. HER2 status in non-small cell lung cancer: results from patient screening for enrollment to a phase II study of herceptin.

    PubMed

    Heinmöller, Petra; Gross, Christof; Beyser, Kurt; Schmidtgen, Claudia; Maass, Gerd; Pedrocchi, Michele; Rüschoff, Josef

    2003-11-01

    For the first time a large number (563) of non-small cell lung cancer (NSCLC) samples was used to compare three different technologies for the assessment of HER2 status. Fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) were used for tumor tissue samples, and ELISA for serum samples. The results were compared with other tumor entities, mainly breast. Samples (563) from patients suffering from primary advanced or metastatic NSCLC were evaluated. HER2 overexpression was demonstrated using IHC in 20% (83 of 410) of the specimens, whereas 2% (7 of 378) were positive by FISH and 6% (31 of 511) showed elevated serum HER2 levels (>15 ng/ml) by ELISA. Sixty-six specimens were positive by IHC only and 13 by ELISA only, whereas none of the specimens was positive only by FISH. Concordance between all of the techniques was seen for only 3 specimens. Of 7 IHC 3+ specimens, 4 showed gene amplification by FISH, and 3 were positive by ELISA (>15 ng/ml), whereas of 76 IHC 2+ cases only 2 were amplified by FISH, and 4 were positive by ELISA. HER2 positivity by at least one of the three techniques was most common in adenocarcinomas, at 29% (42 of 143). Gene amplification and HER2 protein overexpression at the 3+ level appear to be uncommon in NSCLC. The concordance between FISH and IHC 3+ disease was good in this study, in addition, ELISA would have detected several patients without IHC/FISH-positive disease.

  8. [Intraocular and serum antibody titers to Leptospira in 150 horses with equine recurrent uveitis (ERU) subjected to vitrectomy].

    PubMed

    Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P

    1998-04-01

    Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.

  9. Comparison of different strategies in prenatal screening for Down's syndrome: cost effectiveness analysis of computer simulation.

    PubMed

    Gekas, Jean; Gagné, Geneviève; Bujold, Emmanuel; Douillard, Daniel; Forest, Jean-Claude; Reinharz, Daniel; Rousseau, François

    2009-02-13

    To assess and compare the cost effectiveness of three different strategies for prenatal screening for Down's syndrome (integrated test, sequential screening, and contingent screenings) and to determine the most useful cut-off values for risk. Computer simulations to study integrated, sequential, and contingent screening strategies with various cut-offs leading to 19 potential screening algorithms. The computer simulation was populated with data from the Serum Urine and Ultrasound Screening Study (SURUSS), real unit costs for healthcare interventions, and a population of 110 948 pregnancies from the province of Québec for the year 2001. Cost effectiveness ratios, incremental cost effectiveness ratios, and screening options' outcomes. The contingent screening strategy dominated all other screening options: it had the best cost effectiveness ratio ($C26,833 per case of Down's syndrome) with fewer procedure related euploid miscarriages and unnecessary terminations (respectively, 6 and 16 per 100,000 pregnancies). It also outperformed serum screening at the second trimester. In terms of the incremental cost effectiveness ratio, contingent screening was still dominant: compared with screening based on maternal age alone, the savings were $C30,963 per additional birth with Down's syndrome averted. Contingent screening was the only screening strategy that offered early reassurance to the majority of women (77.81%) in first trimester and minimised costs by limiting retesting during the second trimester (21.05%). For the contingent and sequential screening strategies, the choice of cut-off value for risk in the first trimester test significantly affected the cost effectiveness ratios (respectively, from $C26,833 to $C37,260 and from $C35,215 to $C45,314 per case of Down's syndrome), the number of procedure related euploid miscarriages (from 6 to 46 and from 6 to 45 per 100,000 pregnancies), and the number of unnecessary terminations (from 16 to 26 and from 16 to 25 per 100,000 pregnancies). Contingent screening, with a first trimester cut-off value for high risk of 1 in 9, is the preferred option for prenatal screening of women for pregnancies affected by Down's syndrome.

  10. Severity of iron overload of proband determines serum ferritin levels in families with HFE-related hemochromatosis: the HEmochromatosis FAmily Study.

    PubMed

    Jacobs, Esther M G; Hendriks, Jan C M; van Deursen, Cees Th B M; Kreeftenberg, Herman G; de Vries, Richard A; Marx, Joannes J M; Stalenhoef, Anton F H; Verbeek, André L M; Swinkels, Dorine W

    2009-01-01

    In families of patients with clinically detected hereditary hemochromatosis (HH) early screening has been suggested to prevent morbidity and mortality. Here, we aim to identify determinants for iron overload in first-degree family members of C282Y homozygous probands with clinically detected HH. Data on HFE-genotype, iron parameters, demographics, lifestyle factors and health, were collected from 224 Dutch C282Y homozygous patients with clinically diagnosed HH and 735 of their first-degree family members (FDFM), all participating in the HEmochromatosis FAmily Study (HEFAS). The best predictive multivariable model forecasted 45% of variation of the serum ferritin levels. In this model severity of iron overload in the proband significantly predicted serum ferritin levels in FDFM. Other significant determinants in this model consisted of C282Y homozygosity, compound heterozygosity, age at testing for serum ferritin and supplemental iron intake, whereas a low body mass index showed a protective effect. This study provides a model to assess the risk of development of iron overload for relatives of probands with HH. These results might be instrumental in the development of an optimal strategy for future family screening programs.

  11. The evolution of lung cancer screening.

    PubMed

    Wilkinson, Neal W; Loewen, Gregory M; Klippenstein, Donald L; Litwin, Alan M; Anderson, Timothy M

    2003-12-01

    In the 1970s, four trials failed to demonstrate any mortality reduction using a combination of chest X-ray (CXR) and/or sputum cytology. The recent early lung cancer action project (ELCAP) demonstrated that modern screening is capable of detecting Stage I lung cancers. Bronchial epithelial changes leading up to cancers are now being understood to include histologic changes and genetic alterations. Emerging molecular markers detected in sputum and serum show promise in the future of lung cancer screening.

  12. Piezoelectric immunochip for the detection of dengue fever in viremia phase.

    PubMed

    Wu, Tzong-Zeng; Su, Chih-Cheng; Chen, Li-Kuang; Yang, Hui-Hua; Tai, Dar-Fu; Peng, Kou-Cheng

    2005-11-15

    The global prevalence of dengue fever has grown so dramatically in recent years that it is endemic in more than 100 countries and has become a major international public health concern. Moreover, since the flu-like symptoms that accompany dengue fever are atypical and varied, the detection procedures currently used to identify it are cumbersome and time-consuming, making early stage epidemiological control and effective medical treatment of this epidemic almost impossible. In this study, a QCM-based detection system was developed in which two monoclonal antibodies against dengue E and NS-1 protein, respectively, were control orientated immobilized on QCM via protein A to produce an immunochip. Various sample pretreatment procedures were evaluated to ascertain the most suitable combination, and both the simulating samples and the clinical specimen were examined by the immunochip. The results revealed that the cibacron blue 3GA gel-heat denature (CB-HD) method was the most effective sample pretreatment technique. Due to the complex composition of the serum, the immunochip could only effectively quantify dengue viral antigens in a 1/1000 untreated simulated sample. With the help of the CB-HD method, the dilution folds were found to capable of being reduced from 1000 to 100, and the detection limit lowered to 1.727 microg/ml (E protein) and 0.740 microg/ml (NS-1 protein) in the original sample. While the cocktail immunochip could not quantify both antigens separately, the higher signal level rendered it a more effective qualification tool for suspect screening. Moreover, the results of the analysis of clinical specimens also proved the ability and future potential of cocktail immunochip in discriminating dengue-positive cases from negative serum specimens in the viremia phase.

  13. Chronic Kidney Disease Screening Methods and Its Implication for Malaysia: An in Depth Review

    PubMed Central

    Almualm, Yasmin; Huri, Hasniza Zaman

    2015-01-01

    Chronic Kidney Disease has become a public health problem, imposing heath, social and human cost on societies worldwide. Chronic Kidney Disease remains asymptomatic till late stage when intervention cannot stop the progression of the disease. Therefore, there is an urgent need to detect the disease early. Despite the high prevalence of Chronic Kidney Disease in Malaysia, screening is still lacking behind. This review discusses the strengths and limitations of current screening methods for Chronic Kidney Disease from a Malaysian point of view. Diabetic Kidney Disease was chosen as focal point as Diabetes is the leading cause of Chronic Kidney Disease in Malaysia. Screening for Chronic Kidney Disease in Malaysia includes a urine test for albuminuria and a blood test for serum creatinine. Recent literature indicates that albuminuria is not always present in Diabetic Kidney Disease patients and serum creatinine is only raised after substantial kidney damage has occurred. Recently, cystatin C was proposed as a potential marker for kidney disease but this has not been studied thoroughly in Malaysia. Glomerular Filtration Rate is the best method for measuring kidney function and is widely estimated using the Modification of Diet for Renal Disease equation. Another equation, the Chronic Kidney Disease Epidemiology Collaboration Creatinine equation was introduced in 2009. The new equation retained the precision and accuracy of the Modification of Diet for Renal Disease equation at GFR < 60ml/min/1.73m2, showed less bias and improved precision at GFR>60ml/min/1.73m2. In Asian countries, adding an ethnic coefficient to the equation enhanced its performance. In Malaysia, a multi-ethnic Asian population, the Chronic Kidney Disease Epidemiology Collaboration equation should be validated and the Glomerular Filtration Rate should be reported whenever serum creatinine is ordered. Reporting estimated Glomerular Filtration Rate will help diagnose patients who would have been otherwise missed if only albuminuria and serum creatinine are measured. PMID:25946939

  14. Chronic kidney disease screening methods and its implication for Malaysia: an in depth review.

    PubMed

    Almualm, Yasmin; Zaman Huri, Hasniza

    2015-01-01

    Chronic Kidney Disease has become a public health problem, imposing heath, social and human cost on societies worldwide. Chronic Kidney Disease remains asymptomatic till late stage when intervention cannot stop the progression of the disease. Therefore, there is an urgent need to detect the disease early. Despite the high prevalence of Chronic Kidney Disease in Malaysia, screening is still lacking behind. This review discusses the strengths and limitations of current screening methods for Chronic Kidney Disease from a Malaysian point of view. Diabetic Kidney Disease was chosen as focal point as Diabetes is the leading cause of Chronic Kidney Disease in Malaysia. Screening for Chronic Kidney Disease in Malaysia includes a urine test for albuminuria and a blood test for serum creatinine. Recent literature indicates that albuminuria is not always present in Diabetic Kidney Disease patients and serum creatinine is only raised after substantial kidney damage has occurred.  Recently, cystatin C was proposed as a potential marker for kidney disease but this has not been studied thoroughly in Malaysia.  Glomerular Filtration Rate is the best method for measuring kidney function and is widely estimated using the Modification of Diet for Renal Disease equation. Another equation, the Chronic Kidney Disease Epidemiology Collaboration Creatinine equation was introduced in 2009. The new equation retained the precision and accuracy of the Modification of Diet for Renal Disease equation at GFR < 60ml/min/1.73m2, showed less bias and improved precision at GFR>60ml/min/1.73m2. In Asian countries, adding an ethnic coefficient to the equation enhanced its performance. In Malaysia, a multi-ethnic Asian population, the Chronic Kidney Disease Epidemiology Collaboration equation should be validated and the Glomerular Filtration Rate should be reported whenever serum creatinine is ordered. Reporting estimated Glomerular Filtration Rate will help diagnose patients who would have been otherwise missed if only albuminuria and serum creatinine are measured.

  15. Seroprevalence of Powassan virus in New England deer, 1979-2010.

    PubMed

    Nofchissey, Robert A; Deardorff, Eleanor R; Blevins, Tia M; Anishchenko, Michael; Bosco-Lauth, Angela; Berl, Erica; Lubelczyk, Charles; Mutebi, John-Paul; Brault, Aaron C; Ebel, Gregory D; Magnarelli, Louis A

    2013-06-01

    Powassan virus and its subtype, deer tick virus, are closely related tick-borne flaviviruses that circulate in North America. The incidence of human infection by these agents appears to have increased in recent years. To define exposure patterns among white-tailed deer, potentially useful sentinels that are frequently parasitized by ticks, we screened serum samples collected during 1979-2010 in Connecticut, Maine, and Vermont for neutralizing antibody by using a novel recombinant deer tick virus-West Nile virus chimeric virus. Evidence of exposure was detected in all three states. Overall our results demonstrate that seroprevalence is variable in time and space, suggesting that risk of exposure to Powassan virus is similarly variable.

  16. Seroprevalence of Powassan Virus in New England Deer, 1979–2010

    PubMed Central

    Nofchissey, Robert A.; Deardorff, Eleanor R.; Blevins, Tia M.; Anishchenko, Michael; Bosco-Lauth, Angela; Berl, Erica; Lubelczyk, Charles; Mutebi, John-Paul; Brault, Aaron C.; Ebel, Gregory D.; Magnarelli, Louis A.

    2013-01-01

    Powassan virus and its subtype, deer tick virus, are closely related tick-borne flaviviruses that circulate in North America. The incidence of human infection by these agents appears to have increased in recent years. To define exposure patterns among white-tailed deer, potentially useful sentinels that are frequently parasitized by ticks, we screened serum samples collected during 1979–2010 in Connecticut, Maine, and Vermont for neutralizing antibody by using a novel recombinant deer tick virus–West Nile virus chimeric virus. Evidence of exposure was detected in all three states. Overall our results demonstrate that seroprevalence is variable in time and space, suggesting that risk of exposure to Powassan virus is similarly variable. PMID:23568288

  17. Tularaemia seroprevalence of captured and wild animals in Germany: the fox (Vulpes vulpes) as a biological indicator.

    PubMed

    Kuehn, A; Schulze, C; Kutzer, P; Probst, C; Hlinak, A; Ochs, A; Grunow, R

    2013-04-01

    A total of 2475 animals from Germany, both captive and wild, were tested for antibodies against Francisella tularensis to obtain more knowledge about the presence of this pathogen in Germany. An indirect and a competitive ELISA served as screening methods, positive and inconclusive samples were confirmed by Western blot. Of the zoo animals sampled between 1992 and 2007 (n = 1122), three (0·3%) were seropositive. The seroconversion of a hippopotamus in Berlin Zoo was documented. From 1353 serum samples of wild foxes (Vulpes vulpes), raccoon dogs (Nyctereutes procyonoides) and wild boars (Sus scrofa), collected between 2005 and 2009 in the federal state of Brandenburg (surrounding Berlin), a total of 101 (7·5%) tested positive for antibodies to F. tularensis lipopolysaccharide. Our results indicate a higher seroprevalence of F. tularensis in wildlife in eastern Germany than commonly assumed. Furthermore, we found foxes and raccoon dogs to be biological indicators for tularaemia.

  18. A Combined Fabrication and Instrumentation Platform for Sample Preparation.

    PubMed

    Guckenberger, David J; Thomas, Peter C; Rothbauer, Jacob; LaVanway, Alex J; Anderson, Meghan; Gilson, Dan; Fawcett, Kevin; Berto, Tristan; Barrett, Kevin; Beebe, David J; Berry, Scott M

    2014-06-01

    While potentially powerful, access to molecular diagnostics is substantially limited in the developing world. Here we present an approach to reduced cost molecular diagnostic instrumentation that has the potential to empower developing world communities by reducing costs through streamlining the sample preparation process. In addition, this instrument is capable of producing its own consumable devices on demand, reducing reliance on assay suppliers. Furthermore, this instrument is designed with an "open" architecture, allowing users to visually observe the assay process and make modifications as necessary (as opposed to traditional "black box" systems). This open environment enables integration of microfluidic fabrication and viral RNA purification onto an easy-to-use modular system via the use of interchangeable trays. Here we employ this system to develop a protocol to fabricate microfluidic devices and then use these devices to isolate viral RNA from serum for the measurement of human immunodeficiency virus (HIV) viral load. Results obtained from this method show significantly reduced error compared with similar nonautomated sample preparation processes. © 2014 Society for Laboratory Automation and Screening.

  19. A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yijia; Zeinhom, Mohamed M. A.; Yang, Mingming

    Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B,more » for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.« less

  20. Toxoplasmosis serology: an efficient hemagglutination procedure to detect IgG and IgM antibodies.

    PubMed

    Camargo, M E; Moura, M E; Leser, P G

    1989-01-01

    In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo, an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A--rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Top