Sample records for screening study volume

  1. Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

    NASA Technical Reports Server (NTRS)

    Hejduk, M. D.; Pachura, D. A.

    2017-01-01

    Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

  2. Estimation of the costs of cervical cancer screening, diagnosis and treatment in rural Shanxi Province, China: a micro-costing study

    PubMed Central

    2012-01-01

    Background Cost estimation is a central feature of health economic analyses. The aim of this study was to use a micro-costing approach and a societal perspective to estimate aggregated costs associated with cervical cancer screening, diagnosis and treatment in rural China. Methods We assumed that future screening programs will be organized at a county level (population ~250,000), and related treatments will be performed at county or prefecture hospitals; therefore, this study was conducted in a county and a prefecture hospital in Shanxi during 2008–9. Direct medical costs were estimated by gathering information on quantities and prices of drugs, supplies, equipment and labour. Direct non-medical costs were estimated via structured patient interviews and expert opinion. Results Under the base case assumption of a high-volume screening initiative (11,475 women screened annually per county), the aggregated direct medical costs of visual inspection, self-sampled careHPV (Qiagen USA) screening, clinician-sampled careHPV, colposcopy and biopsy were estimated as US$2.64,$7.49,$7.95,$3.90 and $5.76, respectively. Screening costs were robust to screening volume (<5% variation if 2,000 women screened annually), but costs of colposcopy/biopsy tripled at the lower volume. Direct medical costs of Loop Excision, Cold-Knife Conization and Simple and Radical Hysterectomy varied from $61–544, depending on the procedure and whether conducted at county or prefecture level. Direct non-medical expenditure varied from $0.68–$3.09 for screening/diagnosis and $83–$494 for pre-cancer/cancer treatment. Conclusions Diagnostic costs were comparable to screening costs for high-volume screening but were greatly increased in lower-volume situations, which is a key consideration for the scale-up phase of new programs. The study’s findings will facilitate cost-effectiveness evaluation and budget planning for cervical cancer prevention initiatives in China. PMID:22624619

  3. Assessment of Uncertainty-Based Screening Volumes for NASA Robotic LEO and GEO Conjunction Risk Assessment

    NASA Technical Reports Server (NTRS)

    Narvet, Steven W.; Frigm, Ryan C.; Hejduk, Matthew D.

    2011-01-01

    Conjunction Assessment operations require screening assets against the space object catalog by placing a pre-determined spatial volume around each asset and predicting when another object will violate that volume. The selection of the screening volume used for each spacecraft is a trade-off between observing all conjunction events that may pose a potential risk to the primary spacecraft and the ability to analyze those predicted events. If the screening volumes are larger, then more conjunctions can be observed and therefore the probability of a missed detection of a high risk conjunction event is small; however, the amount of data which needs to be analyzed increases. This paper characterizes the sensitivity of screening volume size to capturing typical orbit uncertainties and the expected number of conjunction events observed. These sensitivities are quantified in the form of a trade space that allows for selection of appropriate screen-ing volumes to fit the desired concept of operations, system limitations, and tolerable analyst workloads. This analysis will specifically highlight the screening volume determination and selection process for use in the NASA Conjunction Assessment Risk Analysis process but will also provide a general framework for other Owner / Operators faced with similar decisions.

  4. National Trends in Prostate Biopsy and Radical Prostatectomy Volumes Following the US Preventive Services Task Force Guidelines Against Prostate-Specific Antigen Screening.

    PubMed

    Halpern, Joshua A; Shoag, Jonathan E; Artis, Amanda S; Ballman, Karla V; Sedrakyan, Art; Hershman, Dawn L; Wright, Jason D; Shih, Ya Chen Tina; Hu, Jim C

    2017-02-01

    Studies demonstrate that use of prostate-specific antigen screening decreased significantly following the US Preventive Services Task Force (USPSTF) recommendation against prostate-specific antigen screening in 2012. To determine downstream effects on practice patterns in prostate cancer diagnosis and treatment following the 2012 USPSTF recommendation. Procedural volumes of certifying and recertifying urologists from 2009 through 2016 were evaluated for variation in prostate biopsy and radical prostatectomy (RP) volume. Trends were confirmed using the New York Statewide Planning and Research Cooperative System and Nationwide Inpatient Sample. The study included a representative sample of urologists across practice settings and nationally representative sample of all RP discharges. We obtained operative case logs from the American Board of Urology and identified urologists performing at least 1 prostate biopsy (n = 5173) or RP (n = 3748), respectively. The 2012 USPSTF recommendation against routine population-wide prostate-specific antigen screening. Change in median biopsy and RP volume per urologist and national procedural volume. Following the USPSTF recommendation, median biopsy volume per urologist decreased from 29 to 21 (interquartile range [IQR}, 12-34; P < .001). After adjusting for physician and practice characteristics, biopsy volume decreased by 28.7% following 2012 (parameter estimate, -0.25; SE, 0.03; P < .001). Similarly, following the USPSTF recommendation, median RP volume per urologist decreased from 7 (IQR, 3-15) to 6 (IQR, 2-12) (P < .001), and in adjusted analyses, RP volume decreased 16.2% (parameter estimate, -0.15; SE, 0.05; P = .003). Following the 2012 USPSTF recommendation, prostate biopsy and RP volumes decreased significantly. A panoramic vantage point is needed to evaluate the long-term consequences of the 2012 USPSTF recommendation.

  5. Automated linking of suspicious findings between automated 3D breast ultrasound volumes

    NASA Astrophysics Data System (ADS)

    Gubern-Mérida, Albert; Tan, Tao; van Zelst, Jan; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    Automated breast ultrasound (ABUS) is a 3D imaging technique which is rapidly emerging as a safe and relatively inexpensive modality for screening of women with dense breasts. However, reading ABUS examinations is very time consuming task since radiologists need to manually identify suspicious findings in all the different ABUS volumes available for each patient. Image analysis techniques to automatically link findings across volumes are required to speed up clinical workflow and make ABUS screening more efficient. In this study, we propose an automated system to, given the location in the ABUS volume being inspected (source), find the corresponding location in a target volume. The target volume can be a different view of the same study or the same view from a prior examination. The algorithm was evaluated using 118 linkages between suspicious abnormalities annotated in a dataset of ABUS images of 27 patients participating in a high risk screening program. The distance between the predicted location and the center of the annotated lesion in the target volume was computed for evaluation. The mean ± stdev and median distance error achieved by the presented algorithm for linkages between volumes of the same study was 7.75±6.71 mm and 5.16 mm, respectively. The performance was 9.54±7.87 and 8.00 mm (mean ± stdev and median) for linkages between volumes from current and prior examinations. The proposed approach has the potential to minimize user interaction for finding correspondences among ABUS volumes.

  6. Binary Decision Trees for Preoperative Periapical Cyst Screening Using Cone-beam Computed Tomography.

    PubMed

    Pitcher, Brandon; Alaqla, Ali; Noujeim, Marcel; Wealleans, James A; Kotsakis, Georgios; Chrepa, Vanessa

    2017-03-01

    Cone-beam computed tomographic (CBCT) analysis allows for 3-dimensional assessment of periradicular lesions and may facilitate preoperative periapical cyst screening. The purpose of this study was to develop and assess the predictive validity of a cyst screening method based on CBCT volumetric analysis alone or combined with designated radiologic criteria. Three independent examiners evaluated 118 presurgical CBCT scans from cases that underwent apicoectomies and had an accompanying gold standard histopathological diagnosis of either a cyst or granuloma. Lesion volume, density, and specific radiologic characteristics were assessed using specialized software. Logistic regression models with histopathological diagnosis as the dependent variable were constructed for cyst prediction, and receiver operating characteristic curves were used to assess the predictive validity of the models. A conditional inference binary decision tree based on a recursive partitioning algorithm was constructed to facilitate preoperative screening. Interobserver agreement was excellent for volume and density, but it varied from poor to good for the radiologic criteria. Volume and root displacement were strong predictors for cyst screening in all analyses. The binary decision tree classifier determined that if the volume of the lesion was >247 mm 3 , there was 80% probability of a cyst. If volume was <247 mm 3 and root displacement was present, cyst probability was 60% (78% accuracy). The good accuracy and high specificity of the decision tree classifier renders it a useful preoperative cyst screening tool that can aid in clinical decision making but not a substitute for definitive histopathological diagnosis after biopsy. Confirmatory studies are required to validate the present findings. Published by Elsevier Inc.

  7. The cost of implementation of the Clinical Laboratory Improvement Amendments of 1988--the example of pediatric office-based cholesterol screening.

    PubMed

    Tershakovec, A M; Brannon, S D; Bennett, M J; Shannon, B M

    1995-08-01

    To measure the additional costs of office-based laboratory testing due to the implementation of the Clinical Laboratory Improvement Amendments of 1988 (CLIA '88), using cholesterol screening for children as an example. Four- to ten-year-old children who received their well child care at one of seven participating pediatric practices were screened for hypercholesterolemia. The average number of analyses per day and days per month were derived from the volume of testing completed by the practices. Nurses and technicians time in the screening process were measured and personnel costs were calculated based on salary and fringe benefit rates. Costs of supplies, analyzing control samples, instrument calibration, and instrument depreciation were included. Costs estimates of screening were then completed. CLIA '88 implementation costs were derived from appropriate proficiency testing and laboratory inspection programs. In six practices completing a low volume of testing, 2807 children (5 to 6 children per week) were screened during the observation period, while 414 (about 25 children per week) were screened in one high-volume practice implementing universal screening over a 4-month period. For the six low-volume practices, the cost of screening was $10.60 per child. This decreased to $5.47 for the high-volume practice. Estimated costs of CLIA '88 implementation, including additional proficiency testing and laboratory inspection, added $3.20 per test for the low-volume practices, and $0.71 per test for the high-volume testing. Implementation of CLIA adds significantly to the cost of office-based chemistry laboratory screening. Despite these additional expenses, the cost of testing is still within a reasonable charge for laboratory testing, and is highly sensitive to the volume of tests completed.

  8. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, Michael J; Jacobson, Stephen C

    2012-09-18

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The invention is implemented on a fluidic microchip to provide high serial throughput. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The reaction volumes are manipulated in serial fashion analogous to a digital shift register. The invention has application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  9. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, J Michael [Knoxville, TN; Jacobson, Stephen C [Knoxville, TN

    2007-07-03

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The invention is implemented on a fluidic microchip to provide high serial throughput. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The reaction volumes are manipulated in serial fashion analogous to a digital shift register. The invention has application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  10. Model driver screening and evaluation program. Volume 2, Maryland pilot older driver study

    DOT National Transportation Integrated Search

    2003-05-01

    This research project studied the feasibility as well as the scientific validity and utility of performing functional capacity screening with older drivers. A Model Program was described encompassing procedures to detect functionally impaired drivers...

  11. Robust high-throughput batch screening method in 384-well format with optical in-line resin quantification.

    PubMed

    Kittelmann, Jörg; Ottens, Marcel; Hubbuch, Jürgen

    2015-04-15

    High-throughput batch screening technologies have become an important tool in downstream process development. Although continuative miniaturization saves time and sample consumption, there is yet no screening process described in the 384-well microplate format. Several processes are established in the 96-well dimension to investigate protein-adsorbent interactions, utilizing between 6.8 and 50 μL resin per well. However, as sample consumption scales with resin volumes and throughput scales with experiments per microplate, they are limited in costs and saved time. In this work, a new method for in-well resin quantification by optical means, applicable in the 384-well format, and resin volumes as small as 0.1 μL is introduced. A HTS batch isotherm process is described, utilizing this new method in combination with optical sample volume quantification for screening of isotherm parameters in 384-well microplates. Results are qualified by confidence bounds determined by bootstrap analysis and a comprehensive Monte Carlo study of error propagation. This new approach opens the door to a variety of screening processes in the 384-well format on HTS stations, higher quality screening data and an increase in throughput. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    PubMed Central

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPRfalse-positive rate, sensitivity, and CDRcancer detection rate at all annual interpretive volumes. Conclusion These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow. © RSNA, 2014 Online supplemental material is available for this article. PMID:24960110

  13. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    PubMed

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPR false-positive rate (P = .011) and CDR cancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPR false-positive rate , sensitivity, and CDR cancer detection rate at all annual interpretive volumes. These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow.

  14. Modeling the Dynamics of High-Grade Serous Ovarian Cancer Progression for Transvaginal Ultrasound-Based Screening and Early Detection

    PubMed Central

    Lee, Jung-Min; Levy, Doron

    2016-01-01

    High-grade serous ovarian cancer (HGSOC) represents the majority of ovarian cancers and accounts for the largest proportion of deaths from the disease. A timely detection of low volume HGSOC should be the goal of any screening studies. However, numerous transvaginal ultrasound (TVU) detection-based population studies aimed at detecting low-volume disease have not yielded reduced mortality rates. A quantitative invalidation of TVU as an effective HGSOC screening strategy is a necessary next step. Herein, we propose a mathematical model for a quantitative explanation on the reported failure of TVU-based screening to improve HGSOC low-volume detectability and overall survival.We develop a novel in silico mathematical assessment of the efficacy of a unimodal TVU monitoring regimen as a strategy aimed at detecting low-volume HGSOC in cancer-positive cases, defined as cases for which the inception of the first malignant cell has already occurred. Our findings show that the median window of opportunity interval length for TVU monitoring and HGSOC detection is approximately 1.76 years. This does not translate into reduced mortality levels or improved detection accuracy in an in silico cohort across multiple TVU monitoring frequencies or detection sensitivities. We demonstrate that even a semiannual, unimodal TVU monitoring protocol is expected to miss detectable HGSOC. Lastly, we find that circa 50% of the simulated HGSOC growth curves never reach the baseline detectability threshold, and that on average, 5–7 infrequent, rate-limiting stochastic changes in the growth parameters are associated with reaching HGSOC detectability and mortality thresholds respectively. Focusing on a malignancy poorly studied in the mathematical oncology community, our model captures the dynamic, temporal evolution of HGSOC progression. Our mathematical model is consistent with recent case reports and prospective TVU screening population studies, and provides support to the empirical recommendation against frequent HGSOC screening. PMID:27257824

  15. Occurrence and lung cancer probability of new solid nodules at incidence screening with low-dose CT: analysis of data from the randomised, controlled NELSON trial.

    PubMed

    Walter, Joan E; Heuvelmans, Marjolein A; de Jong, Pim A; Vliegenthart, Rozemarijn; van Ooijen, Peter M A; Peters, Robin B; Ten Haaf, Kevin; Yousaf-Khan, Uraujh; van der Aalst, Carlijn M; de Bock, Geertruida H; Mali, Willem; Groen, Harry J M; de Koning, Harry J; Oudkerk, Matthijs

    2016-07-01

    US guidelines now recommend lung cancer screening with low-dose CT for high-risk individuals. Reports of new nodules after baseline screening have been scarce and are inconsistent because of differences in definitions used. We aimed to identify the occurrence of new solid nodules and their probability of being lung cancer at incidence screening rounds in the Dutch-Belgian Randomized Lung Cancer Screening Trial (NELSON). In the ongoing, multicentre, randomised controlled NELSON trial, between Dec 23, 2003, and July 6, 2006, 15 822 participants who had smoked at least 15 cigarettes a day for more than 25 years or ten cigarettes a day for more than 30 years and were current smokers, or had quit smoking less than 10 years ago, were enrolled and randomly assigned to receive either screening with low-dose CT (n=7915) or no screening (n=7907). From Jan 28, 2004, to Dec 18, 2006, 7557 individuals underwent baseline screening with low-dose CT; 7295 participants underwent second and third screening rounds. We included all participants with solid non-calcified nodules, registered by the NELSON radiologists as new or smaller than 15 mm(3) (study detection limit) at previous screens. Nodule volume was generated semiautomatically by software. We calculated the maximum volume doubling time for nodules with an estimated percentage volume change of 25% or more, representing the minimum growth rate for the time since the previous scan. Lung cancer diagnosis was based on histology, and benignity was based on histology or stable size for at least 2 years. The NELSON trial is registered at trialregister.nl, number ISRCTN63545820. We analysed data for participants with at least one solid non-calcified nodule at the second or third screening round. In the two incidence screening rounds, the NELSON radiologists registered 1222 new solid nodules in 787 (11%) participants. A new solid nodule was lung cancer in 49 (6%) participants with new solid nodules and, in total, 50 lung cancers were found, representing 4% of all new solid nodules. 34 (68%) lung cancers were diagnosed at stage I. Nodule volume had a high discriminatory power (area under the receiver operating curve 0·795 [95% CI 0·728-0·862]; p<0·0001). Nodules smaller than 27 mm(3) had a low probability of lung cancer (two [0·5%] of 417 nodules; lung cancer probability 0·5% [95% CI 0·0-1·9]), nodules with a volume of 27 mm(3) up to 206 mm(3) had an intermediate probability (17 [3·1%] of 542 nodules; lung cancer probability 3·1% [1·9-5·0]), and nodules of 206 mm(3) or greater had a high probability (29 [16·9%] of 172 nodules; lung cancer probability 16·9% [12·0-23·2]). A volume cutoff value of 27 mm(3) or greater had more than 95% sensitivity for lung cancer. Our study shows that new solid nodules are detected at each screening round in 5-7% of individuals who undergo screening for lung cancer with low-dose CT. These new nodules have a high probability of malignancy even at a small size. These findings should be considered in future screening guidelines, and new solid nodules should be followed up more aggressively than nodules detected at baseline screening. Zorgonderzoek Nederland Medische Wetenschappen and Koningin Wilhelmina Fonds Kankerbestrijding. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, J Michael [Knoxville, TN; Jacobson, Stephen C [Knoxville, TN

    2003-02-25

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The method and apparatus are implemented on a fluidic microchip to provide high serial throughput. The method and device of the invention also lend themselves to multiple parallel analyses and manipulation to provide greater throughput for the generation of biochemical information. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter biochemical reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The individual reaction volumes are manipulated in serial fashion analogous to a digital shift register. The method and apparatus according to this invention have application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  17. Nanoliter-Scale Protein Crystallization and Screening with a Microfluidic Droplet Robot

    PubMed Central

    Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun

    2014-01-01

    Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35–96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4–8 nL. The protein consumption significantly reduces 50–500 fold compared with current crystallization stations. PMID:24854085

  18. Nanoliter-scale protein crystallization and screening with a microfluidic droplet robot.

    PubMed

    Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun

    2014-05-23

    Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35-96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4-8 nL. The protein consumption significantly reduces 50-500 fold compared with current crystallization stations.

  19. Model driver screening and evaluation program. Volume 1, Project summary and model program recommendations

    DOT National Transportation Integrated Search

    2003-05-01

    This research project studied the feasibility as well as the scientific validity and utility of performing functional capacity screening with older drivers. A Model Program was described encompassing procedures to detect functionally impaired drivers...

  20. The Relationship of Eye Anomalies and Reading Ability, and an Analysis of Vision-Screening Programs. (Volumes I and II).

    ERIC Educational Resources Information Center

    Francis, Leslie John

    The purpose of this study was to provide an in-depth analysis of vision-screening programs in relation to their efficacy, appropriateness, and feasibility for public school use. Twenty-two vision-screening programs were analyzed for reliability, validity, efficiency of identification and referral cost, and required testing time. Findings are that…

  1. Screening Mammography and Digital Breast Tomosynthesis: Utilization Updates.

    PubMed

    Boroumand, Gilda; Teberian, Ida; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-05-01

    There have been many recent developments in breast imaging, including the 2009 revision of the U.S. Preventive Services Task Force's breast cancer screening guidelines and the approval of digital breast tomosynthesis (DBT) for clinical use in 2011. The objective of this study is to evaluate screening mammography utilization trends among the Medicare population from 2005 to 2015 and examine the volume of DBT studies performed in 2015, the first year for which procedural billing codes for DBT are available. We reviewed national Medicare Part B Physician/Supplier Procedure Summary master files from 2005 to 2015, to determine the annual utilization rate of screening mammography on the basis of procedure codes used for film-screen and digital screening mammography. We also used the Physician/Supplier Procedure Summary master files to determine the volume of screening and diagnostic DBT studies performed in 2015. The utilization rate of screening mammography per 1000 women in the Medicare fee-for-service population increased gradually every year, from 311.5 examinations in 2005 to a peak of 322.9 examinations in 2009, representing a compound annual growth rate of 0.9%. In 2010, the utilization rate abruptly decreased by 4.3% to 309.2 examinations, and it has not since recovered to pre-2010 levels. In 2015, 18.9% of screening and 16.2% of diagnostic digital mammography examinations included DBT as an add-on procedure. In contrast to the annual increase in screening mammography utilization from 2005 to 2009, an abrupt sustained decline in screening occurred beginning in 2010, coinciding with the release of U.S. Preventive Services Task Force recommendations. DBT utilization was somewhat limited in 2015, occurring in conjunction with less than 20% of digital mammography examinations.

  2. Automated assessment of bilateral breast volume asymmetry as a breast cancer biomarker during mammographic screening

    NASA Astrophysics Data System (ADS)

    Williams, Alex C.; Hitt, Austin; Voisin, Sophie; Tourassi, Georgia

    2013-03-01

    The biological concept of bilateral symmetry as a marker of developmental stability and good health is well established. Although most individuals deviate slightly from perfect symmetry, humans are essentially considered bilaterally symmetrical. Consequently, increased fluctuating asymmetry of paired structures could be an indicator of disease. There are several published studies linking bilateral breast size asymmetry with increased breast cancer risk. These studies were based on radiologists' manual measurements of breast size from mammographic images. We aim to develop a computerized technique to assess fluctuating breast volume asymmetry in screening mammograms and investigate whether it correlates with the presence of breast cancer. Using a large database of screening mammograms with known ground truth we applied automated breast region segmentation and automated breast size measurements in CC and MLO views using three well established methods. All three methods confirmed that indeed patients with breast cancer have statistically significantly higher fluctuating asymmetry of their breast volumes. However, statistically significant difference between patients with cancer and benign lesions was observed only for the MLO views. The study suggests that automated assessment of global bilateral asymmetry could serve as a breast cancer risk biomarker for women undergoing mammographic screening. Such biomarker could be used to alert radiologists or computer-assisted detection (CAD) systems to exercise increased vigilance if higher than normal cancer risk is suspected.

  3. Spinning fluids reactor

    DOEpatents

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  4. Maritime patrol aircraft engine study, General Electric Derivative Engines. Volume II. Appendix A: performance data, Ge27/T3 study A1 turboprop. Final report, October 1978-April 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirschkron, R.; Davis, R.H.; Warren, R.E.

    1979-04-30

    This study developed data on General Electric common core derivative engines for use in Maritime Patrol Aircraft (MPA) concept formulation studies. The study included the screening of potential General Electric turbofan and turboprop/turboshaft engines and the preparation of technical and planning information on three of the most promising engine candidates. Screening of General Electric derivative candidates was performed utilizing an analytical MPA model using synthesized mission profiles to rank the candidates in terms of fuel consumption, weight, cost and complexity. The three turboprop engines selected for further study were as follows: TF34 growth derivative version with boost and new LPTmore » (TF34/T7 Study A1), F404 derivative with booster stages and new LPT (F404/T1 Study A1), and GE27 scaled and boosted study engine (GE27/T3 Study A1). Volume I summarizes the screening analysis and contains technical, planning, installation, cost and development data for the three selected turboprop engines. Volumes II, III and IV of this report contain the detailed performance data estimates for the GE27/T3 Study A1, TF34/T7 Study A1 and F404/T1 Study A1 turboprop engines, respectively.« less

  5. Maritime patrol aircraft engine study, General Electric Derivative Engines. Volume IV. Apendix C: performance data, F404/T1 study A1 turboprop. Final report, October 1978-April 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirschkron, R.; Davis, R.H.; Warren, R.E.

    1979-04-30

    This study developed data on General Electric common core derivative engines for use in Maritime Patrol Aircraft (MPA) concept formulation studies. The study included the screening of potential General Electric turbofan and turboprop/turboshaft engines and the preparation of technical and planning information on three of the most promising engine candidates. Screening of General Electric derivative candidates was performed utilizing an analytical MPA model using synthesized mission profiles to rank the candidates in terms of fuel consumption, weight, cost and complexity. The three turboprop engines selected for further study were as follows: TF34 growth derivative version with boost and new LPTmore » (TF34/T7 Study A1), F404 derivative with booster stages and new LPT (F404/T1 Study A1), and GE27 scaled and boosted study engine (GE27/T3 Study A1). Volume I summarizes the screening analysis and contains technical, planning, installation, cost and development data for the three selected turboprop engines. Volumes II, III and IV of this report contain the detailed performance data estimates for the GE27/T3 Study A1, TF34/T7 Study A1 and F404/T1 Study A1 turboprop engines, respectively.« less

  6. Maritime patrol aircraft engine study, General Electric Derivative Engines. Volume III. Appendix B: performance data, TF 34/T7 study AL turboprop. Final report October 1978-April 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirschkron, R.; Davis, R.H.; Warren, R.E.

    1979-04-30

    This study developed data on General Electric common core derivative engines for use in Maritime Patrol Aircraft (MPA) concept formulation studies. The study included the screening of potential General Electric turbofan and turboprop/turboshaft engines and the preparation of technical and planning information on three of the most promising engine candidates. Screening of General Electric derivative candidates was performed utilizing an analytical MPA model using synthesized mission profiles to rank the candidates in terms of fuel consumption, weight, cost and complexity. The three turboprop engines selected for further study were as follows: TF34 growth derivative version with boost and new LPTmore » (TF34/T7 Study A1), F404 derivative with booster stages and new LPT (F404/T1 Study A1), and GE27 scaled and boosted study engine (GE27/T3 Study A1). Volume I summarizes the screening analysis and contains technical, planning, installation, cost and development data for the three selected turboprop engines. Volumes II, III and IV of this report contain the detailed performance data estimates for the GE27/T3 Study A1, TF34/T7 Study A1 and F404/T1 Study A1 turboprop engines, respectively.« less

  7. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    PubMed Central

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473

  8. Resolution V fractional factorial design for screening of factors affecting weakly basic drugs liposomal systems.

    PubMed

    Nageeb El-Helaly, Sara; Habib, Basant A; Abd El-Rahman, Mohamed K

    2018-07-01

    This study aims to investigate factors affecting weakly basic drugs liposomal systems. Resolution V fractional factorial design (2 V 5-1 ) is used as an example of screening designs that would better be used as a wise step before proceeding with detailed factors effects or optimization studies. Five factors probable to affect liposomal systems of weakly basic drugs were investigated using Amisulpride as a model drug. Factors studied were; A: Preparation technique B: Phosphatidyl choline (PhC) amount (mg) C: Cholesterol: PhC molar ratio, D: Hydration volume (ml) and E: Sonication type. Levels investigated were; Ammonium sulphate-pH gradient technique or Transmembrane zinc chelation-pH gradient technique, 200 or 400 mg, 0 or 0.5, 10 or 20 ml and bath or probe sonication for A, B, C, D and E respectively. Responses measured were Particle size (PS) (nm), Zeta potential (ZP) (mV) and Entrapment efficiency percent (EE%). Ion selective electrode was used as a novel method for measuring unentrapped drug concentration and calculating entrapment efficiency without the need for liposomal separation. Factors mainly affecting the studied responses were Cholesterol: PhC ratio and hydration volume for PS, preparation technique for ZP and preparation technique and hydration volume for EE%. The applied 2 V 5-1 design enabled the use of only 16 trial combinations for screening the influence of five factors on weakly basic drugs liposomal systems. This clarifies the value of the use of screening experiments before extensive investigation of certain factors in detailed optimization studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Robotic liquid handling and automation in epigenetics.

    PubMed

    Gaisford, Wendy

    2012-10-01

    Automated liquid-handling robots and high-throughput screening (HTS) are widely used in the pharmaceutical industry for the screening of large compound libraries, small molecules for activity against disease-relevant target pathways, or proteins. HTS robots capable of low-volume dispensing reduce assay setup times and provide highly accurate and reproducible dispensing, minimizing variation between sample replicates and eliminating the potential for manual error. Low-volume automated nanoliter dispensers ensure accuracy of pipetting within volume ranges that are difficult to achieve manually. In addition, they have the ability to potentially expand the range of screening conditions from often limited amounts of valuable sample, as well as reduce the usage of expensive reagents. The ability to accurately dispense lower volumes provides the potential to achieve a greater amount of information than could be otherwise achieved using manual dispensing technology. With the emergence of the field of epigenetics, an increasing number of drug discovery companies are beginning to screen compound libraries against a range of epigenetic targets. This review discusses the potential for the use of low-volume liquid handling robots, for molecular biological applications such as quantitative PCR and epigenetics.

  10. First-trimester screening for early and late preeclampsia using maternal characteristics, biomarkers, and estimated placental volume.

    PubMed

    Sonek, Jiri; Krantz, David; Carmichael, Jon; Downing, Cathy; Jessup, Karen; Haidar, Ziad; Ho, Shannon; Hallahan, Terrence; Kliman, Harvey J; McKenna, David

    2018-01-01

    Preeclampsia is a major cause of perinatal morbidity and mortality. First-trimester screening has been shown to be effective in selecting patients at an increased risk for preeclampsia in some studies. We sought to evaluate the feasibility of screening for preeclampsia in the first trimester based on maternal characteristics, medical history, biomarkers, and placental volume. This is a prospective observational nonintervention cohort study in an unselected US population. Patients who presented for an ultrasound examination between 11-13+6 weeks' gestation were included. The following parameters were assessed and were used to calculate the risk of preeclampsia: maternal characteristics (demographic, anthropometric, and medical history), maternal biomarkers (mean arterial pressure, uterine artery pulsatility index, placental growth factor, pregnancy-associated plasma protein A, and maternal serum alpha-fetoprotein), and estimated placental volume. After delivery, medical records were searched for the diagnosis of preeclampsia. Detection rates for early-onset preeclampsia (<34 weeks' gestation) and later-onset preeclampsia (≥34 weeks' gestation) for 5% and 10% false-positive rates using various combinations of markers were calculated. We screened 1288 patients of whom 1068 (82.99%) were available for analysis. In all, 46 (4.3%) developed preeclampsia, with 13 (1.22%) having early-onset preeclampsia and 33 (3.09%) having late-onset preeclampsia. Using maternal characteristics, serum biomarkers, and uterine artery pulsatility index, the detection rate of early-onset preeclampsia for either 5% or 10% false-positive rate was 85%. With the same protocol, the detection rates for preeclampsia with delivery <37 weeks were 52% and 60% for 5% and 10% false-positive rates, respectively. Based on maternal characteristics, the detection rates for late-onset preeclampsia were 15% and 48% for 5% and 10%, while for preeclampsia at ≥37 weeks' gestation the detection rates were 24% and 43%, respectively. The detection rates for late-onset preeclampsia and preeclampsia with delivery at >37 weeks' gestation were not improved by the addition of biomarkers. Screening for preeclampsia at 11-13+6 weeks' gestation using maternal characteristics and biomarkers is associated with a high detection rate for a low false-positive rate. Screening for late-onset preeclampsia yields a much poorer performance. In this study the utility of estimated placental volume and mean arterial pressure was limited but larger studies are needed to ultimately determine the effectiveness of these markers. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Importance of nasal clipping in screening investigations of flow volume curve.

    PubMed

    Yanev, I

    1992-01-01

    Comparative analysis of some basic lung indices obtained from a screening investigation of the flow volume curve by using two techniques, with a nose clip and without a nose clip, was made on a cohort of 86 workers in a factory shop for the production of bearings. We found no statistically significant differences between the indices obtained by the two techniques. Our study showed that the FVC and FEV1 obtained in workers without using nose clips were equal to or better than those obtained using nose clips in 60% of the workers. The reproducibility of the two methods was similar. The analysis of the data has shown that the flow volume curve investigation gives better results when performed without a nose clip, especially in industrial conditions.

  12. Fishing in the Water: Effect of Sampled Water Volume on Environmental DNA-Based Detection of Macroinvertebrates.

    PubMed

    Mächler, Elvira; Deiner, Kristy; Spahn, Fabienne; Altermatt, Florian

    2016-01-05

    Accurate detection of organisms is crucial for the effective management of threatened and invasive species because false detections directly affect the implementation of management actions. The use of environmental DNA (eDNA) as a species detection tool is in a rapid development stage; however, concerns about accurate detections using eDNA have been raised. We evaluated the effect of sampled water volume (0.25 to 2 L) on the detection rate for three macroinvertebrate species. Additionally, we tested (depending on the sampled water volume) what amount of total extracted DNA should be screened to reduce uncertainty in detections. We found that all three species were detected in all volumes of water. Surprisingly, however, only one species had a positive relationship between an increased sample volume and an increase in the detection rate. We conclude that the optimal sample volume might depend on the species-habitat combination and should be tested for the system where management actions are warranted. Nevertheless, we minimally recommend sampling water volumes of 1 L and screening at least 14 μL of extracted eDNA for each sample to reduce uncertainty in detections when studying macroinvertebrates in rivers and using our molecular workflow.

  13. Determination of depth-viewing volumes for stereo three-dimensional graphic displays

    NASA Technical Reports Server (NTRS)

    Parrish, Russell V.; Williams, Steven P.

    1990-01-01

    Real-world, 3-D, pictorial displays incorporating true depth cues via stereopsis techniques offer a potential means of displaying complex information in a natural way to prevent loss of situational awareness and provide increases in pilot/vehicle performance in advanced flight display concepts. Optimal use of stereopsis requires an understanding of the depth viewing volume available to the display designer. Suggested guidelines are presented for the depth viewing volume from an empirical determination of the effective region of stereopsis cueing (at several viewer-CRT screen distances) for a time multiplexed stereopsis display system. The results provide the display designer with information that will allow more effective placement of depth information to enable the full exploitation of stereopsis cueing. Increasing viewer-CRT screen distances provides increasing amounts of usable depth, but with decreasing fields-of-view. A stereopsis hardware system that permits an increased viewer-screen distance by incorporating larger screen sizes or collimation optics to maintain the field-of-view at required levels would provide a much larger stereo depth-viewing volume.

  14. The plug-based nanovolume Microcapillary Protein Crystallization System (MPCS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerdts, Cory J.; Elliott, Mark; Lovell, Scott

    2012-02-08

    The Microcapillary Protein Crystallization System (MPCS) embodies a new semi-automated plug-based crystallization technology which enables nanolitre-volume screening of crystallization conditions in a plasticware format that allows crystals to be easily removed for traditional cryoprotection and X-ray diffraction data collection. Protein crystals grown in these plastic devices can be directly subjected to in situ X-ray diffraction studies. The MPCS integrates the formulation of crystallization cocktails with the preparation of the crystallization experiments. Within microfluidic Teflon tubing or the microfluidic circuitry of a plastic CrystalCard, {approx}10-20 nl volume droplets are generated, each representing a microbatch-style crystallization experiment with a different chemical composition.more » The entire protein sample is utilized in crystallization experiments. Sparse-matrix screening and chemical gradient screening can be combined in one comprehensive 'hybrid' crystallization trial. The technology lends itself well to optimization by high-granularity gradient screening using optimization reagents such as precipitation agents, ligands or cryoprotectants.« less

  15. US Army Armor Reference Data in Three Volumes. Volume III. Division 86 Organizations.

    DTIC Science & Technology

    1981-01-01

    12 LACE GRAIE SMOKE: SCREENING RP M250 ........................ 58 MOTRYCLE: 2 WHEEL............................................... 8 LAUNCHER...2 TRUCK VAN: SHOP 2-1/2 TON rX6 WE ................................ 2 LAUNCHER GRENAD SMOKE: SCREENING RP M250 ........................ 2 TRUCK...2 ALASM CHEIICAL ACEVT AUTCMATI 0 : ETIL W/PWP .ZP F/iK rIL 1i47TN. !AhJ X’HFR GRFADF SHOKE: SCREENING RP M250 ........................ 14 RATI8C SET

  16. The combined effect of mammographic texture and density on breast cancer risk: a cohort study.

    PubMed

    Wanders, Johanna O P; van Gils, Carla H; Karssemeijer, Nico; Holland, Katharina; Kallenberg, Michiel; Peeters, Petra H M; Nielsen, Mads; Lillholm, Martin

    2018-05-02

    Texture patterns have been shown to improve breast cancer risk segregation in addition to area-based mammographic density. The additional value of texture pattern scores on top of volumetric mammographic density measures in a large screening cohort has never been studied. Volumetric mammographic density and texture pattern scores were assessed automatically for the first available digital mammography (DM) screening examination of 51,400 women (50-75 years of age) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. The texture assessment method was developed in a previous study and validated in the current study. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. All screen-detected breast cancers diagnosed at the first available digital screening examination were excluded. During a median follow-up period of 4.2 (interquartile range (IQR) 2.0-6.2) years, 301 women were diagnosed with breast cancer. The associations between texture pattern scores, volumetric breast density measures and breast cancer risk were determined using Cox proportional hazard analyses. Discriminatory performance was assessed using c-indices. The median age of the women at the time of the first available digital mammography examination was 56 years (IQR 51-63). Texture pattern scores were positively associated with breast cancer risk (hazard ratio (HR) 3.16 (95% CI 2.16-4.62) (p value for trend <0.001), for quartile (Q) 4 compared to Q1). The c-index of texture was 0.61 (95% CI 0.57-0.64). Dense volume and percentage dense volume showed positive associations with breast cancer risk (HR 1.85 (95% CI 1.32-2.59) (p value for trend <0.001) and HR 2.17 (95% CI 1.51-3.12) (p value for trend <0.001), respectively, for Q4 compared to Q1). When adding texture measures to models with dense volume or percentage dense volume, c-indices increased from 0.56 (95% CI 0.53-0.59) to 0.62 (95% CI 0.58-0.65) (p < 0.001) and from 0.58 (95% CI 0.54-0.61) to 0.60 (95% CI 0.57-0.63) (p = 0.054), respectively. Deep-learning-based texture pattern scores, measured automatically on digital mammograms, are associated with breast cancer risk, independently of volumetric mammographic density, and augment the capacity to discriminate between future breast cancer and non-breast cancer cases.

  17. Estimating the cost-per-result of a national reflexed Cryptococcal antigenaemia screening program: Forecasting the impact of potential HIV guideline changes and treatment goals.

    PubMed

    Cassim, Naseem; Coetzee, Lindi Marie; Schnippel, Kathryn; Glencross, Deborah Kim

    2017-01-01

    During 2016, the National Health Laboratory Service (NHLS) introduced laboratory-based reflexed Cryptococcal antigen (CrAg) screening to detect early Cryptococcal disease in immunosuppressed HIV+ patients with a confirmed CD4 count of 100 cells/μl or less. The aim of this study was to assess cost-per-result of a national screening program across different tiers of laboratory service, with variable daily CrAg test volumes. The impact of potential ART treatment guideline and treatment target changes on CrAg volumes, platform choice and laboratory workflow are considered. CD4 data (with counts < = 100 cells/μl) from the fiscal year 2015/16 were extracted from the NHLS Corporate Date Warehouse and used to project anticipated daily CrAg testing volumes with appropriately-matched CrAg testing platforms allocated at each of 52 NHLS CD4 laboratories. A cost-per-result was calculated for four scenarios, including the existing service status quo (Scenario-I), and three other settings (as Scenarios II-IV) which were based on information from recent antiretroviral (ART) guidelines, District Health Information System (DHIS) data and UNAIDS 90/90/90 HIV/AIDS treatment targets. Scenario-II forecast CD4 testing offered only to new ART initiates recorded at DHIS. Scenario-III projected all patients notified as HIV+, but not yet on ART (recorded at DHIS) and Scenario-IV forecast CrAg screening in 90% of estimated HIV+ patients across South Africa (also DHIS). Stata was used to assess daily CrAg volumes at the 5th, 10th, 25th, 50th, 75th, 90th and 95th percentiles across 52 CD4-laboratories. Daily volumes were used to determine technical effort/ operator staff costs (% full time equivalent) and cost-per-result for all scenarios. Daily volumes ranged between 3 and 64 samples for Scenario-I at the 5th and 95th percentile. Similarly, daily volumes ranges of 1-12, 2-45 and 5-100 CrAg-directed samples were noted for Scenario's II, III and IV respectively. A cut-off of 30 CrAg tests per day defined use of either LFA or EIA platform. LFA cost-per-result ranged from $8.24 to $5.44 and EIA cost-per-result between $5.58 and $4.88 across the range of test volumes. The technical effort across scenarios ranged from 3.2-27.6% depending on test volumes and platform used. The study reported the impact of programmatic testing requirements on varying CrAg test volumes that subsequently influenced choice of testing platform, laboratory workflow and cost-per-result. A novel percentiles approach is described that enables an overview of the cost-per-result across a national program. This approach facilitates cross-subsidisation of more expensive lower volume sites with cost-efficient, more centralized higher volume laboratories, mitigating against the risk of costing tests at a single site.

  18. Two-Step Process for ED UTI Screening in Febrile Young Children: Reducing Catheterization Rates.

    PubMed

    Lavelle, Jane M; Blackstone, Mercedes M; Funari, Mary Kate; Roper, Christine; Lopez, Patricia; Schast, Aileen; Taylor, April M; Voorhis, Catherine B; Henien, Mira; Shaw, Kathy N

    2016-07-01

    Urinary tract infection (UTI) screening in febrile young children can be painful and time consuming. We implemented a screening protocol for UTI in a high-volume pediatric emergency department (ED) to reduce urethral catheterization, limiting catheterization to children with positive screens from urine bag specimens. This quality-improvement initiative was implemented using 3 Plan-Do-Study-Act cycles, beginning with a small test of the proposed change in 1 ED area. To ensure appropriate patients received timely screening, care teams discussed patient risk factors and created patient-specific, appropriate procedures. The intervention was extended to the entire ED after providing education. Finally, visual cues were added into the electronic health record, and nursing scripts were developed to enlist family participation. A time-series design was used to study the impact of the 6-month intervention by using a p-chart to determine special cause variation. The primary outcome measure for the study was defined as the catheterization rate in febrile children ages 6 to 24 months. The ED reduced catheterization rates among febrile young children from 63% to <30% over a 6-month period with sustained results. More than 350 patients were spared catheterization without prolonging ED length of stay. Additionally, there was no change in the revisit rate or missed UTIs among those followed within the hospital's network. A 2-step less-invasive process for screening febrile young children for UTI can be instituted in a high-volume ED without increasing length of stay or missing cases of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  19. Analyzing the cost of screening selectee and non-selectee baggage.

    PubMed

    Virta, Julie L; Jacobson, Sheldon H; Kobza, John E

    2003-10-01

    Determining how to effectively operate security devices is as important to overall system performance as developing more sensitive security devices. In light of recent federal mandates for 100% screening of all checked baggage, this research studies the trade-offs between screening only selectee checked baggage and screening both selectee and non-selectee checked baggage for a single baggage screening security device deployed at an airport. This trade-off is represented using a cost model that incorporates the cost of the baggage screening security device, the volume of checked baggage processed through the device, and the outcomes that occur when the device is used. The cost model captures the cost of deploying, maintaining, and operating a single baggage screening security device over a one-year period. The study concludes that as excess baggage screening capacity is used to screen non-selectee checked bags, the expected annual cost increases, the expected annual cost per checked bag screened decreases, and the expected annual cost per expected number of threats detected in the checked bags screened increases. These results indicate that the marginal increase in security per dollar spent is significantly lower when non-selectee checked bags are screened than when only selectee checked bags are screened.

  20. Breast cancer screening in Italy: evaluating key performance indicators for time trends and activity volumes.

    PubMed

    Giordano, Livia; Castagno, Roberta; Giorgi, Daniela; Piccinelli, Cristiano; Ventura, Leonardo; Segnan, Nereo; Zappa, Marco

    2015-01-01

    Together with the National centre for screening monitoring (ONS), GISMa supports annual collection of data on national breast screening activities. Aggregated data on implementation and performance are gathered through a standardized form to calculate process and impact indicators. Analyzed data belong to 153 local programmes in the period 2006-2011 (2006-2012 for participation rate only). During the whole period, Italian crude participation rate exceeded GISMa's acceptable standard (50%), even though a higher participation in northern and central Italy compared to southern Italy and Islands was observed. Time trend analysis of diagnostic indicators confirmed in 2011 an adequate quality of breast screening performance, especially at subsequent screening. Recall rate at initial screening did not reach the acceptable standard (<7%) and rose slightly over the period. On the contrary, a good performance was achieved at subsequent screening. The same trend was followed by the overall detection rate and positive predictive value. They both showed a progressive reduction (from 6.2‰ in 2006 to 4.5‰ in 2011 for DR and from 8.0% in 2006 to 5.2% in 2011 for PPV, respectively) at initial screening and a good, stable trend at subsequent screening. Activity volume analysis shows that in programmes with greater activity (test/year ≥10,000) RR at both initial and subsequent screening has a better performance. This is also true for DR and PPV where programmes with high volumes of activity do better, especially when compared with those that interpret fewer than 5,000 mammograms per year. In spite of a few limits, these results are reassuring, and they reward the efforts made by screening professionals. It is therefore important to continue to monitor screening indicators and suggest, test, and evaluate new strategies for continuous improvement.

  1. Characteristics of new solid nodules detected in incidence screening rounds of low-dose CT lung cancer screening: the NELSON study.

    PubMed

    Walter, Joan E; Heuvelmans, Marjolein A; Bock, Geertruida H de; Yousaf-Khan, Uraujh; Groen, Harry J M; Aalst, Carlijn M van der; Nackaerts, Kristiaan; Ooijen, Peter M A van; Koning, Harry J de; Vliegenthart, Rozemarijn; Oudkerk, Matthijs

    2018-04-16

    New nodules after baseline are regularly found in low-dose CT lung cancer screening and have a high lung cancer probability. It is unknown whether morphological and location characteristics can improve new nodule risk stratification by size. Solid non-calcified nodules detected during incidence screening rounds of the randomised controlled Dutch-Belgian lung cancer screening (NELSON) trial and registered as new or previously below detection limit (15 mm 3 ) were included. A multivariate logistic regression analysis with lung cancer as outcome was performed, including previously established volume cut-offs (<30 mm 3 , 30-<200 mm 3 and ≥200 mm 3 ) and nodule characteristics (location, distribution, shape, margin and visibility <15 mm 3 in retrospect). Overall, 1280 new nodules were included with 73 (6%) being lung cancer. Of nodules ≥30 mm 3 at detection and visible <15 mm 3 in retrospect, 22% (6/27) were lung cancer. Discrimination based on volume cut-offs (area under the receiver operating characteristic curve (AUC): 0.80, 95% CI 0.75 to 0.84) and continuous volume (AUC: 0.82, 95% CI 0.77 to 0.87) was similar. After adjustment for volume cut-offs, only location in the right upper lobe (OR 2.0, P=0.012), central distribution (OR 2.4, P=0.001) and visibility <15 mm 3 in retrospect (OR 4.7, P=0.003) remained significant predictors for lung cancer. The Hosmer-Lemeshow test (P=0.75) and assessment of bootstrap calibration curves indicated adequate model fit. Discrimination based on the continuous model probability (AUC: 0.85, 95% CI 0.81 to 0.89) was superior to volume cut-offs alone, but when stratified into three risk groups (AUC: 0.82, 95% CI 0.78 to 0.86), discrimination was similar. Contrary to morphological nodule characteristics, growth-independent characteristics may further improve volume-based new nodule lung cancer prediction, but in a three-category stratification approach, this is limited. ISRCTN63545820; pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Breast cancer screening services: trade-offs in quality, capacity, outreach, and centralization.

    PubMed

    Güneş, Evrim D; Chick, Stephen E; Akşin, O Zeynep

    2004-11-01

    This work combines and extends previous work on breast cancer screening models by explicitly incorporating, for the first time, aspects of the dynamics of health care states, program outreach, and the screening volume-quality relationship in a service system model to examine the effect of public health policy and service capacity decisions on public health outcomes. We consider the impact of increasing standards for minimum reading volume to improve quality, expanding outreach with or without decentralization of service facilities, and the potential of queueing due to stochastic effects and limited capacity. The results indicate a strong relation between screening quality and the cost of screening and treatment, and emphasize the importance of accounting for service dynamics when assessing the performance of health care interventions. For breast cancer screening, increasing outreach without improving quality and maintaining capacity results in less benefit than predicted by standard models.

  3. Genome-wide association study of coronary and aortic calcification in lung cancer screening CT

    NASA Astrophysics Data System (ADS)

    de Vos, Bob D.; van Setten, Jessica; de Jong, Pim A.; Mali, Willem P.; Oudkerk, Matthijs; Viergever, Max A.; Išgum, Ivana

    2016-03-01

    Arterial calcification has been related to cardiovascular disease (CVD) and osteoporosis. However, little is known about the role of genetics and exact pathways leading to arterial calcification and its relation to bone density changes indicating osteoporosis. In this study, we conducted a genome-wide association study of arterial calcification burden, followed by a look-up of known single nucleotide polymorphisms (SNPs) for coronary artery disease (CAD) and myocardial infarction (MI), and bone mineral density (BMD) to test for a shared genetic basis between the traits. The study included a subcohort of the Dutch-Belgian lung cancer screening trial comprised of 2,561 participants. Participants underwent baseline CT screening in one of two hospitals participating in the trial. Low-dose chest CT images were acquired without contrast enhancement and without ECG-synchronization. In these images coronary and aortic calcifications were identified automatically. Subsequently, the detected calcifications were quantified using coronary artery calcium Agatston and volume scores. Genotype data was available for these participants. A genome-wide association study was conducted on 10,220,814 SNPs using a linear regression model. To reduce multiple testing burden, known CAD/MI and BMD SNPs were specifically tested (45 SNPs from the CARDIoGRAMplusC4D consortium and 60 SNPS from the GEFOS consortium). No novel significant SNPs were found. Significant enrichment for CAD/MI SNPs was observed in testing Agatston and coronary artery calcium volume scores. Moreover, a significant enrichment of BMD SNPs was shown in aortic calcium volume scores. This may indicate genetic relation of BMD SNPs and arterial calcification burden.

  4. Comparison of Adherence to Chlamydia Screening Guidelines Among Title X Providers and Non-Title X Providers in the California Family Planning, Access, Care, and Treatment Program

    PubMed Central

    Thiel de Bocanegra, Heike; Hulett, Denis; Park, Hye-Youn; Darney, Philip

    2012-01-01

    Abstract Background Annual chlamydia screening is recommended for adolescent and young adult females and targeted screening is recommended for women ≥26 years based on risk. Although screening levels have increased over time, adherence to these guidelines varies, with high levels of adherence among Title X family planning providers. However, previous studies of provider variation in screening rates have not adjusted for differences in clinic and client population characteristics. Methods Administrative claims from the California Family Planning, Access, Care, and Treatment (Family PACT) program were used to (1) examine clinic and client sociodemographic characteristics by provider group—Title X-funded public sector, non-Title X public sector, and private sector providers, and (2) estimate age-specific screening and differences in rates by provider group during 2009. Results Among 833 providers, Title X providers were more likely than non-Title X public sector providers and private sector providers to serve a higher client volume, a higher proportion of clients aged ≤25 years, and a higher proportion of African American clients. Non-Title X public providers were more likely to be located in rural areas, compared with Title X grantees and private sector providers. Title X providers had the largest absolute difference in screening rates for young females vs. older females (10.9%). Unadjusted screening rates for young clients were lower among non-Title X public sector providers (54%) compared with private sector and Title X providers (64% each). After controlling for provider group, urban location, client volume, and percent African American, private sector providers had higher screening rates than Title X and non-Title X public providers. Conclusions Screening rates for females were higher among private providers compared with Title X and non-Title X public providers. However, only Title X providers were more likely to adhere to screening guidelines through high screening rates for young females and low screening rates for older females. PMID:22694761

  5. Graduated Frequencies alcohol measures for monitoring consumption patterns: Results from an Australian national survey and a US diary validity study

    PubMed Central

    Greenfield, Thomas K.; Kerr, William C.; Bond, Jason; Ye, Yu; Stockwell, Tim

    2009-01-01

    We investigate several types of graduated frequency (GF) instruments for monitoring drinking patterns. Two studies with 12-month GF measures and daily data were used: (i) the Australian 2004 National Drug Strategy Household Survey (n = 24,109 aged 12+; 22,546 with GF and over 8000 with yesterday data) and (ii) a US methodological study involving a 28-day daily diary plus GF summary measures drawn from the National Alcohol Survey (n = 3,025 screened, 119 eligible study completers). The NDSHS involved (i) “drop and collect” self-completed forms with random sampling methods; the Measurement study (ii) screened 3+ drinkers by telephone and collected 28-day drinking diaries and pre- and post-diary 28-day GFs. We compared mean values for the GF quantity ranges from yesterday’s drinks (study i) and 28-day diaries (study ii), also examining volume influence. Using Yesterday’s drinking, Australian results showed GF quantity range means close to arithmetic midpoints and volume effects only for the lowest two levels (1–2, and 3–4 drinks; p < .001). U.S. calibration results on the GF using 28-day diaries were similar, with a volume effect only at these low quantity levels (p < .001). Means for the highest quantity thresholds were 23.5 drinks for the 20+ (10 gram) drink level (Australia) and 15.5 drinks for the 12+ (14 g) drink level (US). In the US study, summary GF frequency and volume were highly consistent with diary-based counterparts. A conclusion is that algorithms for computing volume may be refined using validation data. We suggest measurement methods may be improved by taking better account of empirical drink ethanol content. PMID:21197381

  6. An effective method to screen sodium-based layered materials for sodium ion batteries

    NASA Astrophysics Data System (ADS)

    Zhang, Xu; Zhang, Zihe; Yao, Sai; Chen, An; Zhao, Xudong; Zhou, Zhen

    2018-03-01

    Due to the high cost and insufficient resource of lithium, sodium-ion batteries are widely investigated for large-scale applications. Typically, insertion-type materials possess better cyclic stability than alloy-type and conversion-type ones. Therefore, in this work, we proposed a facile and effective method to screen sodium-based layered materials based on Materials Project database as potential candidate insertion-type materials for sodium ion batteries. The obtained Na-based layered materials contains 38 kinds of space group, which reveals that the credibility of our screening approach would not be affected by the space group. Then, some important indexes of the representative materials, including the average voltage, volume change and sodium ion mobility, were further studied by means of density functional theory computations. Some materials with extremely low volume changes and Na diffusion barriers are promising candidates for sodium ion batteries. We believe that our classification algorithm could also be used to search for other alkali and multivalent ion-based layered materials, to accelerate the development of battery materials.

  7. A prototype software methodology for the rapid evaluation of biomanufacturing process options.

    PubMed

    Chhatre, Sunil; Francis, Richard; O'Donovan, Kieran; Titchener-Hooker, Nigel J; Newcombe, Anthony R; Keshavarz-Moore, Eli

    2007-10-01

    A three-layered simulation methodology is described that rapidly evaluates biomanufacturing process options. In each layer, inferior options are screened out, while more promising candidates are evaluated further in the subsequent, more refined layer, which uses more rigorous models that require more data from time-consuming experimentation. Screening ensures laboratory studies are focused only on options showing the greatest potential. To simplify the screening, outputs of production level, cost and time are combined into a single value using multi-attribute-decision-making techniques. The methodology was illustrated by evaluating alternatives to an FDA (U.S. Food and Drug Administration)-approved process manufacturing rattlesnake antivenom. Currently, antivenom antibodies are recovered from ovine serum by precipitation/centrifugation and proteolyzed before chromatographic purification. Alternatives included increasing the feed volume, replacing centrifugation with microfiltration and replacing precipitation/centrifugation with a Protein G column. The best alternative used a higher feed volume and a Protein G step. By rapidly evaluating the attractiveness of options, the methodology facilitates efficient and cost-effective process development.

  8. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    PubMed

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias adjusted Kappa value (PABAK) was 0.76 (range 0.6-0.85). Mean time to perform the test was 13.1 min (SD 6.924). The V-VST seems to be a moderately reliable screening tool for detecting OD among medical and geriatric patients. However, the recommendations of volume and viscosity add limited clinical value to the test. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  9. The risk of finding focal cancer (less than 3 mm) remains high on re-biopsy of patients with persistently increased prostate specific antigen but the clinical significance is questionable.

    PubMed

    Zackrisson, Bjørn; Aus, Gunnar; Bergdahl, Svante; Lilja, Hans; Lodding, Pär; Pihl, Carl-Gustav; Hugosson, Jonas

    2004-04-01

    We evaluated the significance of focal prostate cancer found in sextant biopsies in men participating in a biennial prostate specific antigen (PSA) based screening program. In 1995, 10000 men 50 to 65 years old were randomized to biennial screening with PSA testing. Sextant biopsies were recommended when total PSA was 3 ng/ml or greater at screening rounds 1 and 2, and 2.54 ng/ml or greater at subsequent screening rounds. Focal cancer was defined as total a core cancer length of less than 3 mm in the biopsy specimen. Low volume cancer was defined as a total tumor volume of less than 0.5 cm in the radical retropubic prostatectomy specimen. The number of men who underwent biopsy and the number of cancers detected in the 5 possible sets of biopsies were 1725 and 402, 706 and 124, 307 and 36, 103 and 9, and 13 and 0, respectively. The risk of detecting focal cancer was 7.9%, 10.2%, 7.5%, 5.8% and 0%, respectively, but the relative ratio (focal-to-all cancers) increased 34%, 58%, 64%, 67% and, not applicable, respectively. In men with a total core cancer length of less than 10 mm there was no correlation between core cancer length and total tumor volume, as measured in the prostatectomy specimen. Two-thirds of men with a total core cancer length of less than 3 mm had a tumor volume of greater than 0.5 cm, while the risk of low volume cancer was less than 5% only in men with a total core cancer length of greater than 10 mm. In a repeat PSA based screening program sextant biopsies are of little or no value for predicting tumor volume.

  10. Mechanisms of Decreased Plasma Volume During Acute Psychological Stress and Postural Change in Humans

    DTIC Science & Technology

    1993-09-14

    follicular phase of their menstrual cycle as defined as 1 to 11 days post menses . Experimental Protocol Each subject was screened by telephone to...studies exist regarding possible gender differences in plasma volume changes during acute psychological stress. Menstrual cycle effects on physiologic...the different phases of the menstrual cycle (Strauss, Schultheiss, & Cohen, 1983; Carroll , ’I\\lrner I Lee I & Stephenson, 1984). Conflicting

  11. The Evaluation of Screening Process and Local Bureaucracy in Determining the Priority of Urban Roads Maintenance and Rehabilitation

    NASA Astrophysics Data System (ADS)

    Hendhratmoyo, Andri; Syafi'i; Pungky Pramesti, Florentina

    2017-11-01

    Due to the limited budget of urban roads maintenance and rehabilitation, its prioritizationis inevitable. Many models have been developed to solve these problems. That is the reason why the purpose of this study was to evaluate the screening process in the decision making of the urban roads maintenance and rehabilitation priority. The prioritization that have to be taken into account on the effect of important criteria are road condition, traffic volume, budget processing and land use. 30 stakeholders were asked to fill in the questionnaires. The object of this case study are 188 urban roads sections at Ponorogo in order to examine the priorities. The researchers collected the data from Surface Distress Index (SDI), traffic volume, budget processing and land use of these road sections. Based on analysis, the weights of the criteria were: road condition (W1) = 0,411; traffic volume (W2) = 0,122; budget processing (W3) = 0,363 and land use (W4) = 0,105. The result of this study by the comparison of the index values of the alternatives priorities, Nyi Ageng Serang Street, was revealed to have the highest priority over the other streets regarding of maintenance and rehabilitation activities.

  12. Lack of hippocampal volume differences in primary insomnia and good sleeper controls: an MRI volumetric study at 3 Tesla.

    PubMed

    Winkelman, John W; Benson, Kathleen L; Buxton, Orfeu M; Lyoo, In Kyoon; Yoon, Sujung; O'Connor, Shawn; Renshaw, Perry F

    2010-06-01

    A recent pilot study reported that hippocampal volume (HV) was reduced in patients with primary insomnia (PI) relative to normal sleepers. Loss of HV in PI might be due to chronic hyperarousal and/or chronic sleep debt. The aim of this study was to replicate the earlier pilot report while employing a larger sample, more rigorous screening criteria, and objective sleep data. This cross-sectional design included community recruits meeting DSM-IV criteria for PI (n=20, 10 males, mean age 39.3+/-8.7) or good sleeper controls (n=15, 9 males, mean age 38.8+/-5.3). All subjects were unmedicated and rigorously screened to exclude comorbid psychiatric and medical illness. PI subjects underwent overnight polysomnography to screen for sleep-related breathing and movement disorders. HV and total brain volumes were derived by MRI employing a Siemens/Trio scanner operating at 3 Tesla. Data also included 2 weeks of sleep diaries and wrist actigraphy. Mean HV was 4322.0+/-299.7 mm(3) for the good sleeper controls and 4601.55+/-537.4 mm(3) for the PI group. The dependent variable, HV, was analyzed by ANCOVA. Main effects were diagnosis and gender; whole brain volume served as the covariate. Although the overall model was significant (F=6.3, p=0.001), the main effects of diagnosis (F=2.14) and gender (F=0.04) were not significant. The covariate of whole brain volume was significant (F=5.74, p=0.023) as was the interaction of diagnosis with gender (F=10.22, p=0.003), with male insomniacs having larger HVs than male controls. This study did not replicate a previously published report of HV loss in primary insomnia. Differences between our finding and the previous report might be due to sample composition and method of MRI assessment. Furthermore, we demonstrated no objective differences between the controls and PIs in actigraphic measures of sleep maintenance. Within the PIs, however, actigraphic measures of poor sleep maintenance were associated with smaller HV. Copyright 2010 Elsevier B.V. All rights reserved.

  13. The impact of using weight estimated from mammographic images vs. self-reported weight on breast cancer risk calculation

    NASA Astrophysics Data System (ADS)

    Nair, Kalyani P.; Harkness, Elaine F.; Gadde, Soujanye; Lim, Yit Y.; Maxwell, Anthony J.; Moschidis, Emmanouil; Foden, Philip; Cuzick, Jack; Brentnall, Adam; Evans, D. Gareth; Howell, Anthony; Astley, Susan M.

    2017-03-01

    Personalised breast screening requires assessment of individual risk of breast cancer, of which one contributory factor is weight. Self-reported weight has been used for this purpose, but may be unreliable. We explore the use of volume of fat in the breast, measured from digital mammograms. Volumetric breast density measurements were used to determine the volume of fat in the breasts of 40,431 women taking part in the Predicting Risk Of Cancer At Screening (PROCAS) study. Tyrer-Cuzick risk using self-reported weight was calculated for each woman. Weight was also estimated from the relationship between self-reported weight and breast fat volume in the cohort, and used to re-calculate Tyrer-Cuzick risk. Women were assigned to risk categories according to 10 year risk (below average <2%, average 2-3.49%, above average 3.5-4.99%, moderate 5-7.99%, high >=8%) and the original and re-calculated Tyrer-Cuzick risks were compared. Of the 716 women diagnosed with breast cancer during the study, 15 (2.1%) moved into a lower risk category, and 37 (5.2%) moved into a higher category when using weight estimated from breast fat volume. Of the 39,715 women without a cancer diagnosis, 1009 (2.5%) moved into a lower risk category, and 1721 (4.3%) into a higher risk category. The majority of changes were between below average and average risk categories (38.5% of those with a cancer diagnosis, and 34.6% of those without). No individual moved more than one risk group. Automated breast fat measures may provide a suitable alternative to self-reported weight for risk assessment in personalized screening.

  14. Automated screening of propulsion system test data by neural networks, phase 1

    NASA Technical Reports Server (NTRS)

    Hoyt, W. Andes; Whitehead, Bruce A.

    1992-01-01

    The evaluation of propulsion system test and flight performance data involves reviewing an extremely large volume of sensor data generated by each test. An automated system that screens large volumes of data and identifies propulsion system parameters which appear unusual or anomalous will increase the productivity of data analysis. Data analysts may then focus on a smaller subset of anomalous data for further evaluation of propulsion system tests. Such an automated data screening system would give NASA the benefit of a reduction in the manpower and time required to complete a propulsion system data evaluation. A phase 1 effort to develop a prototype data screening system is reported. Neural networks will detect anomalies based on nominal propulsion system data only. It appears that a reasonable goal for an operational system would be to screen out 95 pct. of the nominal data, leaving less than 5 pct. needing further analysis by human experts.

  15. [Surgery for colorectal cancer since the introduction of the Netherlands national screening programmeInvestigations into changes in number of resections and waiting times for surgery].

    PubMed

    de Neree Tot Babberich, M P M; van der Willik, E M; van Groningen, J T; Ledeboer, M; Wiggers, T; Wouters, M W J M

    2017-01-01

    To investigate the impact of the Netherlands national colorectal cancer screening programme on the number of surgical resections for colorectal carcinoma and on waiting times for surgery. Descriptive study. Data were extracted from the Dutch Surgical Colorectal Audit. Patients with primary colorectal cancer surgery between 2011-2015 were included. The volume and median waiting times for the years 2011-2015 are described. Waiting times from first tumor positive biopsy until the operation (biopsy-operation) and first preoperative visit to the surgeon until the operation (visit-operation) are analyzed with a univariate and multivariate linear regression analysis. Separate analysis was done for visit-operation for academic and non-academic hospitals and for screening compared to non-screening patients. In 2014 there was an increase of 1469 (15%) patients compared to 2013. In 2015 this increase consisted of 1168 (11%) patients compared to 2014. In 2014 and 2015, 1359 (12%) and 3111 (26%) patients were referred to the surgeon through screening, respectively. The median waiting time of biopsy-operation significantly decreased (ß: 0.94, 95%BI) over the years 2014-2015 compared to 2011-2013. In non-academic hospitals, the waiting time visit-operation also decreased significantly (ß: 0.89, 95%BI 0.87-0.90) over the years 2014-2015 compared to 2011-2013. No difference was found in waiting times between patients referred to the surgeon through screening compared to non-screening. There is a clear increase in volume since the introduction of the colorectal cancer screening programme without an increase in waiting time until surgery.

  16. Failure of replicating the association between hippocampal volume and 3 single-nucleotide polymorphisms identified from the European genome-wide association study in Asian populations.

    PubMed

    Li, Ming; Ohi, Kazutaka; Chen, Chunhui; He, Qinghua; Liu, Jie-Wei; Chen, Chuansheng; Luo, Xiong-Jian; Dong, Qi; Hashimoto, Ryota; Su, Bing

    2014-12-01

    Hippocampal volume is a key brain structure for learning ability and memory process, and hippocampal atrophy is a recognized biological marker of Alzheimer's disease. However, the genetic bases of hippocampal volume are still unclear although it is a heritable trait. Genome-wide association studies (GWASs) on hippocampal volume have implicated several significantly associated genetic variants in Europeans. Here, to test the contributions of these GWASs identified genetic variants to hippocampal volume in different ethnic populations, we screened the GWAS-identified candidate single-nucleotide polymorphisms in 3 independent healthy Asian brain imaging samples (a total of 990 subjects). The results showed that none of these single-nucleotide polymorphisms were associated with hippocampal volume in either individual or combined Asian samples. The replication results suggested a complexity of genetic architecture for hippocampal volume and potential genetic heterogeneity between different ethnic populations. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Evaluating Spatiotemporal Image Correlation Technology as a Tool for Training Nonexpert Sonographers to Perform Examinations of the Fetal Heart.

    PubMed

    Avnet, Hagai; Mazaaki, Eyal; Shen, Ori; Cohen, Sarah; Yagel, Simcha

    2016-01-01

    We aimed to evaluate the use of spatiotemporal image correlation (STIC) as a tool for training nonexpert examiners to perform screening examinations of the fetal heart by acquiring and examining STIC volumes according to a standardized questionnaire based on the 5 transverse planes of the fetal heart. We conducted a prospective study at 2 tertiary care centers. Two sonographers without formal training in fetal echocardiography received theoretical instruction on the 5 fetal echocardiographic transverse planes, as well as STIC technology. Only women with conditions allowing 4-dimensional STIC volume acquisitions (grayscale and Doppler) were included in the study. Acquired volumes were evaluated offline according to a standardized protocol that required the trainee to mark 30 specified structures on 5 required axial planes. Volumes were then reviewed by an expert examiner for quality of acquisition and correct identification of specified structures. Ninety-six of 112 pregnant women examined entered the study. Patients had singleton pregnancies between 20 and 32 weeks' gestation. After an initial learning curve of 20 examinations, trainees succeeded in identifying 97% to 98% of structures, with a highly significant degree of agreement with the expert's analysis (P < .001). A median of 2 STIC volumes for each examination was necessary for maximal structure identification. Acquisition quality scores were high (8.6-8.7 of a maximal score of 10) and were found to correlate with identification rates (P = .017). After an initial learning curve and under expert guidance, STIC is an excellent tool for trainees to master extended screening examinations of the fetal heart.

  18. Examination and evaluation of the use of screen heaters for the measurement of the high temperature pyrolysis kinetics of polyethene and polypropene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westerhout, R.W.J.; Balk, R.H.P.; Meijer, R.

    1997-08-01

    A screen heater with a gas sweep was developed and applied to study the pyrolysis kinetics of low density polyethene (LDPE) and polypropene (PP) at temperatures ranging from 450 to 530 C. The aim of this study was to examine the applicability of screen heaters to measure these kinetics. On-line measurement of the rate of volatiles formation using a hydrocarbon analyzer was applied to enable the determination of the conversion rate over the entire conversion range on the basis of a single experiment. Another important feature of the screen heater used in this study is the possibility to measure pyrolysismore » kinetics under nearly isothermal conditions. The kinetic constants for LDPE and PP pyrolysis were determined, using a first order model to describe the conversion rate in the 70--90% conversion range and the random chain dissociation model for the entire conversion range. In addition to the experimental work two single particle models have been developed which both incorporate a mass and a (coupled) enthalpy balance, which were used to assess the influence of internal and external heat transfer processes on the pyrolysis process. The first model assumes a variable density and constant volume during the pyrolysis process, whereas the second model assumes a constant density and a variable volume. An important feature of these models is that they can accommodate kinetic models for which no analytical representation of the pyrolysis kinetics is available.« less

  19. Top Value Added Chemicals From Biomass. Volume 1 - Results of Screening for Potential Candidates From Sugars and Synthesis Gas

    DTIC Science & Technology

    2004-08-01

    Hydrogenation of sugars or extraction from biomass pretreatment processes. Very few if any. Commercial processes Non-nutritive sweeteners ...and no commercial production of arabinitol. Xylitol is used as a non-nutritive sweetener . The technology required to convert the five carbon sugars ...Top Value Added Chemicals from Biomass Volume I—Results of Screening for Potential Candidates from Sugars and Synthesis Gas Produced by

  20. Screening Smoke Performance of Commercially Available Powders. 2. Visible Screening by Titanium Dioxide

    DTIC Science & Technology

    1994-06-01

    NY 10562 (Continued on page ii) 12a. DISTRIBUTION I AVAILABILITY STATEMENT 12b. DISTRIBUTION CODE Approved for public release; distribution is...the weight F., volume (1,. and financial ()F limited figures of merit for numerous grades of commercially available titania are listed in Table 1...is usefull in volume limited applications such as grenades, rockets, artillery rounds, mortars and smoke pots. The third figure of merit gives the

  1. Usefulness of the volume-viscosity swallow test for screening dysphagia in subacute stroke patients in rehabilitation income.

    PubMed

    Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran

    2013-01-01

    Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.

  2. The professional quality criteria of Italian breast screening radiologists: results from a national survey comparing the programmes started in 2000-2012 versus the ones started in 1990-1999.

    PubMed

    Morrone, Doralba; Giordano, Livia; Artuso, Franca; Bernardi, Daniela; Fedato, Chiara; Frigerio, Alfonso; Giorgi, Daniela; Naldoni, Carlo; Saguatti, Gianni; Severi, Daniela; Taffurelli, Mario; Terribile, Daniela; Ventura, Leonardo; Bucchi, Lauro

    2017-01-01

    In Italy, due to increasing healthcare budget and staff shortages, the recently created regional mammography screening programmes were established under worse radiology practice quality criteria than the previously created programmes. Using available data from a national questionnaire survey conducted at the end of 2013 and involving 222 responder radiologists, we compared the main professional quality standards of radiologists working in the screening programmes established during the period 2000-2012 with those working in the screening programmes created from 1990 to 1999. The former reported more years of clinical experience in breast imaging and a greater clinical mammogram reading volume than the latter. Conversely, they dedicated less working time to breast imaging, were less likely to participate in the diagnostic assessment of screen-detected lesions, to work in large-staffed screening centres, and to have a screening and a total mammogram reading volume (SMRV and TMRV) ≥ 5000 per year. The level of most professional quality criteria of Italian mammography screening radiologists has decreased over time. As SMRV and TMRV are important predictors of diagnostic accuracy, we can expect a lower interpretation performance of radiologists working in the recently created screening programmes.

  3. In vivo growth of 60 non-screening detected lung cancers: a computed tomography study.

    PubMed

    Mets, Onno M; Chung, Kaman; Zanen, Pieter; Scholten, Ernst T; Veldhuis, Wouter B; van Ginneken, Bram; Prokop, Mathias; Schaefer-Prokop, Cornelia M; de Jong, Pim A

    2018-04-01

    Current pulmonary nodule management guidelines are based on nodule volume doubling time, which assumes exponential growth behaviour. However, this is a theory that has never been validated in vivo in the routine-care target population. This study evaluates growth patterns of untreated solid and subsolid lung cancers of various histologies in a non-screening setting.Growth behaviour of pathology-proven lung cancers from two academic centres that were imaged at least three times before diagnosis (n=60) was analysed using dedicated software. Random-intercept random-slope mixed-models analysis was applied to test which growth pattern most accurately described lung cancer growth. Individual growth curves were plotted per pathology subgroup and nodule type.We confirmed that growth in both subsolid and solid lung cancers is best explained by an exponential model. However, subsolid lesions generally progress slower than solid ones. Baseline lesion volume was not related to growth, indicating that smaller lesions do not grow slower compared to larger ones.By showing that lung cancer conforms to exponential growth we provide the first experimental basis in the routine-care setting for the assumption made in volume doubling time analysis. Copyright ©ERS 2018.

  4. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    EPA Pesticide Factsheets

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  5. Prostate-specific antigen screening impacts on biochemical recurrence in patients with clinically localized prostate cancer.

    PubMed

    Hashimoto, Takeshi; Ohori, Makoto; Shimodaira, Kenji; Kaburaki, Naoto; Hirasawa, Yosuke; Satake, Naoya; Gondo, Tatsuo; Nakagami, Yoshihiro; Namiki, Kazunori; Ohno, Yoshio

    2018-06-01

    To clarify the impact of prostate-specific antigen screening on surgical outcomes of prostate cancer. Patients who underwent radical prostatectomy were divided into two groups according to prostate-specific antigen testing opportunity (group 1, prostate-specific antigen screening; group 2, non-prostate-specific antigen screening). Perioperative clinical characteristics were compared using the Wilcoxon rank-sum and χ 2 -tests. Cox proportional hazards models were used to identify independent predictors of postoperative biochemical recurrence-free survival. In total, 798 patients (63.2%) and 464 patients (36.8%) were categorized into groups 1 and 2, respectively. Group 2 patients were more likely to have a higher prostate-specific antigen level and age at diagnosis and larger prostate volume. Clinical T stage, percentage of positive cores and pathological Gleason score did not differ between the groups. The 5-year biochemical recurrence-free survival rate was 83.9% for group 1 and 71.0% for group 2 (P < 0.001). On multivariate analysis, prostate-specific antigen testing opportunity (hazard ratio 2.530; P < 0.001) was an independent predictive factor for biochemical recurrence after surgery, as well as pathological T stage, pathological Gleason score, positive surgical margin and lymphovascular invasion. Additional analyses showed that prostate-specific antigen screening had a greater impact on biochemical recurrence in a younger patients, patients with a high prostate-specific antigen level, large prostate volume and D'Amico high risk, and patients meeting the exclusion criteria of the Prostate Cancer Research International Active Surveillance study. Detection by screening results in favorable outcomes after surgery. Prostate-specific antigen screening might contribute to reducing biochemical recurrence in patients with localized prostate cancer. © 2018 The Japanese Urological Association.

  6. Bioprinting 3D cell-laden hydrogel microarray for screening human periodontal ligament stem cell response to extracellular matrix.

    PubMed

    Ma, Yufei; Ji, Yuan; Huang, Guoyou; Ling, Kai; Zhang, Xiaohui; Xu, Feng

    2015-12-22

    Periodontitis is an inflammatory disease negatively affecting up to 15% of adults worldwide. Periodontal ligament stem cells (PDLSCs) hold great promises for periodontal tissue regeneration, where it is necessary to find proper extracellular matrix (ECM) materials (e.g., composition, concentration). In this study, we proposed a bioprinting-based approach to generate nano-liter sized three-dimensional (3D) cell-laden hydrogel array with gradient of ECM components, through controlling the volume ratio of two hydrogels, such as gelatin methacrylate (GelMA) and poly(ethylene glycol) (PEG) dimethacrylate. The resulting cell-laden array with a gradient of GelMA/PEG composition was used to screen human PDLSC response to ECM. The behavior (e.g., cell viability, spreading) of human PDLSCs in GelMA/PEG array were found to be depended on the volume ratios of GelMA/PEG, with cell viability and spreading area decreased along with increasing the ratio of PEG. The developed approach would be useful for screening cell-biomaterial interaction in 3D and promoting regeneration of functional tissue.

  7. Effect of hydration on interstitial distribution of charged albumin in rat dermis in vitro

    PubMed Central

    Wiig, Helge; Tenstad, Olav; Bert, Joel L

    2005-01-01

    At physiological pH, negatively charged glycosaminoglycans in the extracellular matrix may influence distribution volume of macromolecular probes, a phenomenon of importance for hydration of the interstitium and therefore for body fluid balance. We hypothesized that such charge effect was dependent on hydration. Human serum albumin (HSA) (the pH value for the isoelectric point (pI) = 4.9) was made neutral by cationization (cHSA) (pI = 7.6). Rat dermis was studied in vitro in a specially designed equilibration cell allowing control of hydration. Using a buffer containing labelled native HSA and cHSA, the distribution volumes were calculated relative to that of 51Cr-EDTA, an extracellular tracer. During changes in hydration (H), defined as (wet weight – dry weight) (dry weight)−1), the slope of the equation describing the relationship between extracellular fluid volume (Vx) (in g H2O (g dry weight)−1) and H (Vx = 0.925 H + 0.105) differed significantly from that for available volumes of cHSA (Va,cHSA = 0.624 H – 0.538) and HSA (Va,HSA = 0.518 H – 0.518). A gradual reduction in H led to a reduction in difference between available volumes for the two albumin species. Screening the fixed charges by 1 m NaCl resulted in similar available and excluded volumes of native HSA and neutral cHSA. We conclude that during gradual dehydration, there is a reduced effect of fixed negative charges on interstitial exclusion of charged macromolecules. This effect may be explained by a reduced hydration domain surrounding tissue and probe macromolecules in conditions of increased electrostatic interactions. Furthermore, screening of negative charges suggested that hyaluronan associated with collagen may influence intrafibrillar volume of collagen and thereby available and excluded volume fraction. PMID:16210353

  8. Role of stranded gas in increasing global gas supplies

    USGS Publications Warehouse

    Attanasi, E.D.; Freeman, P.A.

    2013-01-01

    This report synthesizes the findings of three regional studies in order to evaluate, at the global scale, the contribution that stranded gas resources can make to global natural gas supplies. Stranded gas, as defined for this study, is natural gas in discovered conventional gas and oil fields that is currently not commercially producible for either physical or economic reasons. The regional studies evaluated the cost of bringing the large volumes of undeveloped gas in stranded gas fields to selected markets. In particular, stranded gas fields of selected Atlantic Basin countries, north Africa, Russia, and central Asia are screened to determine whether the volumes are sufficient to meet Europe’s increasing demand for gas imports. Stranded gas fields in Russia, central Asia, Southeast Asia, and Australia are also screened to estimate development, production, and transport costs and corresponding gas volumes that could be supplied to Asian markets in China, India, Japan, and South Korea. The data and cost analysis presented here suggest that for the European market and the markets examined in Asia, the development of stranded gas provides a way to meet projected gas import demands for the 2020-to-2040 period. Although this is a reconnaissance-type appraisal, it is based on volumes of gas that are associated with individual identified fields. Individual field data were carefully examined. Some fields were not evaluated because current technology was insufficient or it appeared the gas was likely to be held off the export market. Most of the evaluated stranded gas can be produced and delivered to markets at costs comparable to historical prices. Moreover, the associated volumes of gas are sufficient to provide an interim supply while additional technologies are developed to unlock gas diffused in shale and hydrates or while countries transition to making a greater use of renewable energy sources.

  9. 76 FR 4549 - Testing of Certain High Production Volume Chemicals; Second Group of Chemicals; Technical Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... Testing of Certain High Production Volume Chemicals; Second Group of Chemicals; Technical Correction... production volume (HPV) chemical substances to obtain screening level data for health and environmental effects and chemical fate. This document is being issued to correct a typographical error concerning the...

  10. Predictors of poor adherence of U.S. gastroenterologists with colonoscopy screening and surveillance guidelines

    PubMed Central

    Iskandar, Heba; Yan, Yan; Elwing, Jill; Early, Dayna; Colditz, Graham A.; Wang, Jean S.

    2014-01-01

    Background The U.S. Multi-Society Task Force on Colorectal Cancer published guidelines for colonoscopy screening and surveillance in 2008 and affirmed them in 2012. Characteristics associated with guideline adherence among U.S. gastroenterologists have not been assessed. Aims Assess awareness and adherence of U.S. gastroenterologists with national guidelines for colonoscopy screening and surveillance and predictors of adherence to guidelines. Methods A web-based survey was administered to gastroenterologists in various practice settings across the United States. Results A total of 306 gastroenterologists completed the survey; 86% reported awareness of the guidelines. Low-volume colonoscopists (<20 /month) were less likely to be aware of the guidelines (OR 0.26, p=0.03) compared to high-volume colonoscopists (>100/month). Those completing training before 1990 were less likely to report following guidelines (OR 0.37, p=0.01). Adherence with guidelines was then assessed via clinical scenarios. Compared to physicians finishing training in 1991-2010, less adherence was seen in those finishing before 1990 (OR 0.75, p<0.001) or currently in training (OR 0.72, p=0.004). Compared to the Western U.S., less adherence was seen in the Midwest (OR 0.69, p=0.001), Northeast (OR 0.63, p<0.001), and South (OR 0.59, p<0.001). Lower adherence was seen among non-academic physicians (OR 0.72, p=0.001) and low-volume colonoscopists (OR 0.52, p<0.001). Conclusions There is poor adherence with colonoscopy screening and surveillance guidelines among U.S. gastroenterologists. Poor adherence was associated with being in training or finishing training before 1990, practicing in the South, non-academic settings, and low colonoscopy volume. These findings can target interventions for quality improvement in colorectal cancer screening and surveillance. PMID:25366146

  11. Predictors of Poor Adherence of US Gastroenterologists with Colonoscopy Screening and Surveillance Guidelines.

    PubMed

    Iskandar, Heba; Yan, Yan; Elwing, Jill; Early, Dayna; Colditz, Graham A; Wang, Jean S

    2015-04-01

    The US Multi-Society Task Force on Colorectal Cancer published guidelines for colonoscopy screening and surveillance in 2008 and affirmed them in 2012. Characteristics associated with guideline adherence among US gastroenterologists have not been assessed. Assess awareness and adherence of US gastroenterologists with national guidelines for colonoscopy screening and surveillance and predictors of adherence to guidelines. A Web-based survey was administered to gastroenterologists in various practice settings across the USA. A total of 306 gastroenterologists completed the survey; 86 % reported awareness of the guidelines. Low-volume colonoscopists (<20/month) were less likely to be aware of the guidelines (OR 0.26, p = 0.03) compared to high-volume colonoscopists (>100/month). Those completing training before 1990 were less likely to report following guidelines (OR 0.37, p = 0.01). Adherence with guidelines was then assessed via clinical scenarios. Compared to physicians finishing training in 1991-2010, less adherence was seen in those finishing before 1990 (OR 0.75, p < 0.001) or currently in training (OR 0.72, p = 0.004). Compared to the Western USA, less adherence was seen in the Midwest (OR 0.69, p = 0.001), Northeast (OR 0.63, p < 0.001), and South (OR 0.59, p < 0.001). Lower adherence was seen among non-academic physicians (OR 0.72, p = 0.001) and low-volume colonoscopists (OR 0.52, p < 0.001). There is poor adherence with colonoscopy screening and surveillance guidelines among US gastroenterologists. Poor adherence was associated with being in training or finishing training before 1990, practicing in the South, non-academic settings, and low colonoscopy volume. These findings can target interventions for quality improvement in colorectal cancer screening and surveillance.

  12. Fluorescence-based high-throughput screening of dicer cleavage activity.

    PubMed

    Podolska, Katerina; Sedlak, David; Bartunek, Petr; Svoboda, Petr

    2014-03-01

    Production of small RNAs by ribonuclease III Dicer is a key step in microRNA and RNA interference pathways, which employ Dicer-produced small RNAs as sequence-specific silencing guides. Further studies and manipulations of microRNA and RNA interference pathways would benefit from identification of small-molecule modulators. Here, we report a study of a fluorescence-based in vitro Dicer cleavage assay, which was adapted for high-throughput screening. The kinetic assay can be performed under single-turnover conditions (35 nM substrate and 70 nM Dicer) in a small volume (5 µL), which makes it suitable for high-throughput screening in a 1536-well format. As a proof of principle, a small library of bioactive compounds was analyzed, demonstrating potential of the assay.

  13. Microscale screening systems for 3D cellular microenvironments: platforms, advances, and challenges

    PubMed Central

    Montanez-Sauri, Sara I.; Beebe, David J.; Sung, Kyung Eun

    2015-01-01

    The increasing interest in studying cells using more in vivo-like three-dimensional (3D) microenvironments has created a need for advanced 3D screening platforms with enhanced functionalities and increased throughput. 3D screening platforms that better mimic in vivo microenvironments with enhanced throughput would provide more in-depth understanding of the complexity and heterogeneity of microenvironments. The platforms would also better predict the toxicity and efficacy of potential drugs in physiologically relevant conditions. Traditional 3D culture models (e.g. spinner flasks, gyratory rotation devices, non-adhesive surfaces, polymers) were developed to create 3D multicellular structures. However, these traditional systems require large volumes of reagents and cells, and are not compatible with high throughput screening (HTS) systems. Microscale technology offers the miniaturization of 3D cultures and allows efficient screening of various conditions. This review will discuss the development, most influential works, and current advantages and challenges of microscale culture systems for screening cells in 3D microenvironments. PMID:25274061

  14. Dual-Axis Rotational Angiography is Safe and Feasible to Detect Coronary Allograft Vasculopathy in Pediatric Heart Transplant Patients: A Single-Center Experience.

    PubMed

    Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M

    2016-04-01

    Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.

  15. Gas pressure assisted microliquid-liquid extraction coupled online to direct infusion mass spectrometry: a new automated screening platform for bioanalysis.

    PubMed

    Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas

    2014-10-21

    In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.

  16. Dose–Volume Modeling of Brachial Plexus-Associated Neuropathy After Radiation Therapy for Head-and-Neck Cancer: Findings From a Prospective Screening Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Allen M., E-mail: amchen@mednet.ucla.edu; Wang, Pin-Chieh; Daly, Megan E.

    2014-03-15

    Purpose: Data from a prospective screening protocol administered for patients previously irradiated for head-and-neck cancer was analyzed to identify dosimetric predictors of brachial plexus-associated neuropathy. Methods and Materials: Three hundred fifty-two patients who had previously completed radiation therapy for squamous cell carcinoma of the head and neck were prospectively screened from August 2007 to April 2013 using a standardized self-administered instrument for symptoms of neuropathy thought to be related to brachial plexus injury. All patients were disease-free at the time of screening. The median time from radiation therapy was 40 months (range, 6-111 months). A total of 177 patients (50%)more » underwent neck dissection. Two hundred twenty-one patients (63%) received concurrent chemotherapy. Results: Fifty-one patients (14%) reported brachial plexus-related neuropathic symptoms with the most common being ipsilateral pain (50%), numbness/tingling (40%), and motor weakness and/or muscle atrophy (25%). The 3- and 5-year estimates of freedom from brachial plexus-associated neuropathy were 86% and 81%, respectively. Clinical/pathological N3 disease (P<.001) and maximum radiation dose to the ipsilateral brachial plexus (P=.01) were significantly associated with neuropathic symptoms. Cox regression analysis revealed significant dose–volume effects for brachial plexus-associated neuropathy. The volume of the ipsilateral brachial plexus receiving >70 Gy (V70) predicted for symptoms, with the incidence increasing with V70 >10% (P<.001). A correlation was also observed for the volume receiving >74 Gy (V74) among patients treated without neck dissection, with a cutoff of 4% predictive of symptoms (P=.038). Conclusions: Dose–volume guidelines were developed for radiation planning that may limit brachial plexus-related neuropathies.« less

  17. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis

    PubMed Central

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting

    2015-01-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 “borderline” samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. PMID:25972403

  18. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

    PubMed

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-07-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Automated Propulsion Data Screening demonstration system

    NASA Technical Reports Server (NTRS)

    Hoyt, W. Andes; Choate, Timothy D.; Whitehead, Bruce A.

    1995-01-01

    A fully-instrumented firing of a propulsion system typically generates a very large quantity of data. In the case of the Space Shuttle Main Engine (SSME), data analysis from ground tests and flights is currently a labor-intensive process. Human experts spend a great deal of time examining the large volume of sensor data generated by each engine firing. These experts look for any anomalies in the data which might indicate engine conditions warranting further investigation. The contract effort was to develop a 'first-cut' screening system for application to SSME engine firings that would identify the relatively small volume of data which is unusual or anomalous in some way. With such a system, limited and expensive human resources could focus on this small volume of unusual data for thorough analysis. The overall project objective was to develop a fully operational Automated Propulsion Data Screening (APDS) system with the capability of detecting significant trends and anomalies in transient and steady-state data. However, the effort limited screening of transient data to ground test data for throttle-down cases typical of the 3-g acceleration, and for engine throttling required to reach the maximum dynamic pressure limits imposed on the Space Shuttle. This APDS is based on neural networks designed to detect anomalies in propulsion system data that are not part of the data used for neural network training. The delivered system allows engineers to build their own screening sets for application to completed or planned firings of the SSME. ERC developers also built some generic screening sets that NASA engineers could apply immediately to their data analysis efforts.

  20. Factors associated with failure to screen newborns for retinopathy of prematurity.

    PubMed

    Bain, Lisa Charo; Dudley, R Adams; Gould, Jeffrey B; Lee, Henry C

    2012-11-01

    To evaluate ROP screening rates in a population-based cohort; and to identify characteristics of patients that were missed. We used the California Perinatal Quality Care Collaborative data from 2005-2007 for a cross-sectional study. Using eligibility criteria, screening rates were calculated for each hospital. Multivariable regression was used to assess associations between patient clinical and sociodemographic factors and the odds of missing screening. Overall rates of missed ROP screening decreased from 18.6% in 2005 to 12.8% in 2007. Higher gestational age (OR = 1.25 for increase of 1 week, 95% CI, 1.21-1.29), higher birth weight (OR = 1.13; 95% CI, 1.10-1.15), and singleton birth (OR = 1.2; 95% CI, 1.07-1.34) were associated with higher probability of missing screening. Level II neonatal intensive care units and neonatal intensive care units with lower volume were more likely to miss screenings. Although ROP screening rates improved over time, larger and older infants are at risk for not receiving screening. Furthermore, large variations in screening rates exist among hospitals in California. Identification of gaps in quality of care creates an opportunity to improve ROP screening rates and prevent impaired vision in this vulnerable population. Copyright © 2012 Mosby, Inc. All rights reserved.

  1. 76 FR 1067 - Testing of Certain High Production Volume Chemicals; Second Group of Chemicals

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ... 2070-AD16 Testing of Certain High Production Volume Chemicals; Second Group of Chemicals AGENCY... processors of certain high production volume (HPV) chemical substances to conduct testing to obtain screening... potentially affected by this action if you manufacture (defined by statute to include import) or process any...

  2. Study and design of cryogenic propellant acquisition systems. Volume 2: Supporting experimental program

    NASA Technical Reports Server (NTRS)

    Burge, G. W.; Blackmon, J. B.

    1973-01-01

    Areas of cryogenic fuel systems were identified where critical experimental information was needed either to define a design criteria or to establish the feasibility of a design concept or a critical aspect of a particular design. Such data requirements fell into three broad categories: (1) basic surface tension screen characteristics; (2) screen acquisition device fabrication problems; and (3) screen surface tension device operational failure modes. To explore these problems and to establish design criteria where possible, extensive laboratory or bench test scale experiments were conducted. In general, these proved to be quite successful and, in many instances, the test results were directly used in the system design analyses and development. In some cases, particularly those relating to operational-type problems, areas requiring future research were identified, especially screen heat transfer and vibrational effects.

  3. Advanced controls for airbreathing engines, volume 3: Allison gas turbine

    NASA Technical Reports Server (NTRS)

    Bough, R. M.

    1993-01-01

    The application of advanced control concepts to airbreathing engines may yield significant improvements in aircraft/engine performance and operability. Screening studies of advanced control concepts for airbreathing engines were conducted by three major domestic aircraft engine manufacturers to determine the potential impact of concepts on turbine engine performance and operability. The purpose of the studies was to identify concepts which offered high potential yet may incur high research and development risk. A target suite of proposed advanced control concepts was formulated and evaluated in a two-phase study to quantify each concept's impact on desired engine characteristics. To aid in the evaluation specific aircraft/engine combinations were considered: a Military High Performance Fighter mission, a High Speed Civil Transport mission, and a Civil Tiltrotor mission. Each of the advanced control concepts considered in the study are defined and described. The concept potential impact on engine performance was determined. Relevant figures of merit on which to evaluate the concepts are determined. Finally, the concepts are ranked with respect to the target aircraft/engine missions. A final report describing the screening studies was prepared by each engine manufacturer. Volume 3 of these reports describes the studies performed by the Allison Gas Turbine Division.

  4. Advanced control for airbreathing engines, volume 1: Pratt and Whitney

    NASA Technical Reports Server (NTRS)

    Ralph, J. A.

    1993-01-01

    The application of advanced control concepts to air breathing engines may yield significant improvements in aircraft/engine performance and operability. Screening studies of advanced control concepts for air breathing engines were conducted by three major domestic aircraft engine manufacturers to determine the potential impact of concepts on turbine engine performance and operability. The purpose of the studies was to identify concepts which offered high potential yet may incur high research and development risk. A target suite of proposed advanced control concepts was formulated and evaluated in a two phase study to quantify each concept's impact on desired engine characteristics. To aid in the evaluation specific aircraft/engine combinations were considered: a Military High Performance Fighter mission, a High Speed Civil Transport mission, and a Civil Tiltrotor mission. Each of the advanced control concepts considered in the study are defined and described. The concept potential impact on engine performance was determined. Relevant figures of merit on which to evaluate the concepts are determined. Finally, the concepts are ranked with respect to the target aircraft/engine missions. A final report describing the screening studies was prepared by each engine manufacturer. Volume 1 of these reports describes the studies performed by Pratt & Whitney.

  5. Advanced control for airbreathing engines, volume 2: General Electric aircraft engines

    NASA Technical Reports Server (NTRS)

    Bansal, Indar

    1993-01-01

    The application of advanced control concepts to air breathing engines may yield significant improvements in aircraft/engine performance and operability. Screening studies of advanced control concepts for air breathing engines were conducted by three major domestic aircraft engine manufacturers to determine the potential impact of concepts on turbine engine performance and operability. The purpose of the studies was to identify concepts which offered high potential yet may incur high research and development risk. A target suite of proposed advanced control concepts was formulated and evaluated in a two phase study to quantify each concept's impact on desired engine characteristics. To aid in the evaluation specific aircraft/engine combinations were considered: a Military High Performance Fighter mission, a High Speed Civil Transport mission, and a Civil Tiltrotor mission. Each of the advanced control concepts considered in the study are defined and described. The concept potential impact on engine performance was determined. Relevant figures of merit on which to evaluate the concepts are determined. Finally, the concepts are ranked with respect to the target aircraft/engine missions. A final report describing the screening studies was prepared by each engine manufacturer. Volume 2 of these reports describes the studies performed by GE Aircraft Engines.

  6. AOPs & Biomarkers: Bridging High Throughput Screening and Regulatory Decision Making.

    EPA Science Inventory

    As high throughput screening (HTS) approaches play a larger role in toxicity testing, computational toxicology has emerged as a critical component in interpreting the large volume of data produced. Computational models for this purpose are becoming increasingly more sophisticated...

  7. Efficient screening for COPD using three steps: a cross-sectional study in Mexico City.

    PubMed

    Franco-Marina, Francisco; Fernandez-Plata, Rosario; Torre-Bouscoulet, Luis; García-Sancho, Cecilia; Sanchez-Gallen, Elisa; Martinez, David; Perez-Padilla, Rogelio

    2014-05-20

    Underdiagnosis of chronic obstructive pulmonary disease (COPD) in primary care can be improved by a more efficient screening strategy. To evaluate a three-step method of screening for COPD consisting of an initial short questionnaire followed by measurement of forced expiratory volume in 1s/forced expiratory volume in 6s (FEV1/FEV6) using an inexpensive pocket spirometer in those with high risk, and diagnostic quality spirometry in those with a low FEV1/FEV6. We analysed two related Mexico City cross-sectional samples. The 2003 Mexico City PLATINO survey (n=542) was used to develop a short questionnaire to determine the risk of COPD and a 2010 survey (n=737) additionally used a pocket spirometer. The discriminatory power of the two instruments was assessed with receiver operator characteristic (ROC) curves using three COPD definitions. The developed COPD scale included two variables from a simple questionnaire and, in ROC analysis, an area under the curve (AUC) between 0.64 and 0.77 was found to detect COPD. The pocket spirometer had an AUC between 0.85 and 0.88 to detect COPD. Using the COPD scale as a first screening step excluded 35-48% of the total population from further testing at the cost of not detecting 8-18% of those with COPD. Using the pocket spirometer and sending those with a FEV1/FEV6<0.80 for diagnostic quality spirometry is very efficient, and substantially improved the positive predictive value at the cost of not detecting one-third of COPD cases. A three-step screening strategy for COPD substantially reduces the need for spirometry testing when only a COPD scale is used for screening.

  8. The volume-viscosity swallow test for clinical screening of dysphagia and aspiration.

    PubMed

    Rofes, Laia; Arreola, Viridiana; Clavé, Pere

    2012-01-01

    Oropharyngeal dysphagia (OD) is a major complaint among many patients with neurological diseases and in the elderly, but is often underdiagnosed. The volume-viscosity swallow test (V-VST) is a bedside method to screen patients for dysphagia. The V-VST was designed to identify clinical signs of impaired efficacy (labial seal, oral and pharyngeal residue, and piecemeal deglutition) and impaired safety of swallow (voice changes, cough and decrease in oxygen saturation ≥3%). It starts with nectar viscosity and increasing bolus volume, then liquid and finally pudding viscosity in a progression of increasing difficulty to protect patients from aspiration. The V-VST allows quick, safe and accurate screening for OD in hospitalized and independently living patients with multiple etiologies. The V-VST presents a sensitivity of 88.2% and a specificity of 64.7% to detect clinical signs of impaired safety of swallow (aspiration or penetration). The test takes 5-10 min to complete. The V-VST is an excellent tool to screen patients for OD. It combines good psychometric properties, a detailed and easy protocol designed to protect safety of patients, and valid end points to evaluate safety and efficacy of swallowing and detect silent aspirations. Copyright © 2012 S. Karger AG, Basel.

  9. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    PubMed

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Microplate-Based Method for High-Throughput Screening (HTS) of Chromatographic Conditions Studies for Recombinant Protein Purification.

    PubMed

    Carvalho, Rimenys J; Cruz, Thayana A

    2018-01-01

    High-throughput screening (HTS) systems have emerged as important tools to provide fast and low cost evaluation of several conditions at once since it requires small quantities of material and sample volumes. These characteristics are extremely valuable for experiments with large number of variables enabling the application of design of experiments (DoE) strategies or simple experimental planning approaches. Once, the capacity of HTS systems to mimic chromatographic purification steps was established, several studies were performed successfully including scale down purification. Here, we propose a method for studying different purification conditions that can be used for any recombinant protein, including complex and glycosylated proteins, using low binding filter microplates.

  11. Can one blood draw replace transrectal ultrasonography-estimated prostate volume to predict prostate cancer risk?

    PubMed

    Carlsson, Sigrid V; Peltola, Mari T; Sjoberg, Daniel; Schröder, Fritz H; Hugosson, Jonas; Pettersson, Kim; Scardino, Peter T; Vickers, Andrew J; Lilja, Hans; Roobol, Monique J

    2013-09-01

    To explore whether a panel of kallikrein markers in blood: total, free and intact prostate-specific antigen (PSA) and kallikrein-related peptidase 2, could be used as a non-invasive alternative for predicting prostate cancer on biopsy in a screening setting. The study cohort comprised previously unscreened men who underwent sextant biopsy owing to elevated PSA (≥3 ng/mL) in two different centres of the European Randomized Study of Screening for Prostate Cancer, Rotterdam (n = 2914) and Göteborg (n = 740). A statistical model, based on kallikrein markers, was compared with one based on established clinical factors for the prediction of biopsy outcome. The clinical tests were found to be no better than blood markers, with an area under the curve in favour of the blood measurements of 0.766 vs. 0.763 in Rotterdam and 0.809 vs. 0.774 in Göteborg. Adding digital rectal examination (DRE) or DRE plus transrectal ultrasonography (TRUS) volume to the markers improved discrimination, although the increases were small. Results were similar for predicting high-grade cancer. There was a strong correlation between the blood measurements and TRUS-estimated prostate volume (Spearman's correlation 0.60 in Rotterdam and 0.57 in Göteborg). In previously unscreened men, each with indication for biopsy, a statistical model based on kallikrein levels was similar to a clinical model in predicting prostate cancer in a screening setting, outside the day-to-day clinical practice. Whether a clinical approach can be replaced by laboratory analyses or used in combination with decision models (nomograms) is a clinical judgment that may vary from clinician to clinician depending on how they weigh the different advantages and disadvantages (harms, costs, time, invasiveness) of both approaches. © 2013 BJU International.

  12. Older driver self-screening based on health concerns. Volume 2, Appendices

    DOT National Transportation Integrated Search

    2008-10-01

    The objective of this project was to create a valid and effective Web-based self-screening instrument to provide older drivers with individualized information to help them make better decisions about driving. The project was intended to improve upon ...

  13. HYDROCARBON SPILL SCREENING MODEL (HSSM) VOLUME 1: USER'S GUIDE

    EPA Science Inventory

    This users guide describes the Hydrocarbon Spill Screening Model (HSSM). The model is intended for simulation of subsurface releases of light nonaqueous phase liquids (LNAPLs). The model consists of separate modules for LNAPL flow through the vadose zone, spreading in the capil...

  14. Older driver self-screening based on health concerns. Volume 1, Technical Report

    DOT National Transportation Integrated Search

    2008-10-01

    The objective of this project was to create a valid and effective Web-based self-screening instrument to provide older drivers with individualized information to help them make better decisions about driving. The project was intended to improve upon ...

  15. The Shock and Vibration Digest, Volume 13, Number 1

    DTIC Science & Technology

    1981-01-01

    Transfer matrices of different elements constituting expansion chamber mufflers have been used to develop a computer program for designing a... developed general computer programs using 10 ^=3 m^ Figure 4. Suppression of Flow-Acoustic Coupling by a Bridge Perforate [57] Figure 5. A Generally...the paper sessions are: • Environmental Stress Screening Theory • Screening Program Development /Implementa- tion • Screening Case Histories

  16. ELECTROCHEMICAL TECHNIQUE FOR TNT USING DISPOSABLE SCREEN-PRINTED ELECTRODE

    EPA Science Inventory

    Screen-printed thick film electrodes are demonstrated as voltammetric sensors for measurement of 2,4,6-trinitrotoluene (TNT). The square wave voltammetric (SWV) scan technique is used to measure TNT in as little as 50 uL sample volumes. This electrochemical assay is coupled ...

  17. AOPs and Biomarkers: Bridging High Throughput Screening and Regulatory Decision Making

    EPA Science Inventory

    As high throughput screening (HTS) plays a larger role in toxicity testing, camputational toxicology has emerged as a critical component in interpreting the large volume of data produced. Computational models designed to quantify potential adverse effects based on HTS data will b...

  18. A screening mammography program. Staying alive and making it work.

    PubMed

    Monsees, B S; Destouet, J M

    1992-01-01

    The success of a mammography screening program requires thorough planning. A dependably high volume and a streamlined efficient operation are essential to survival of the program. Factors that warrant consideration prior to designing such a program include the following: Distinction between screening and diagnostic mammography examinations. Selection of a site that will meet the needs of the community and yet provide a consistently high volume. Low examination cost for screening mammography coupled with a detailed financial analysis and reappraisal on an ongoing basis. A customized marketing program that incorporates methods to increase awareness, compliance, and utilization by women and referring physicians. Well-trained, efficient, and dedicated personnel. An operation that is designed for rapid throughput and expeditious patient flow. An efficient plan for film handling, interpretation, reporting, and storage. Timely communication of examination results. A reliable mechanism for follow-up evaluation and outcome data collection. Establishment of a consistent and reliable quality assurance program and the production of high quality mammograms.

  19. Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists

    PubMed Central

    Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.

    2011-01-01

    Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640

  20. Validation of Student and Parent Report Data on the Basic Grant Application Form. Final Report. Volume I, Individual Validation Studies: Institution Referral Study, Pre-established Criteria Study.

    ERIC Educational Resources Information Center

    Vogel, Ronald J.

    Errors made on applications to the Basic Educational Opportunity Grant (BEOG) program were studied to determine the scope and nature of misreporting and misuse of the BEOG program. Characteristics of applicants who misreport personal and/or family financial circumstances were identified, and procedures were established to regularly screen and…

  1. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  2. Sedentary Screen Time and Left Ventricular Structure and Function: the CARDIA Study

    PubMed Central

    Gibbs, Bethany Barone; Reis, Jared P.; Schelbert, Erik B.; Craft, Lynette L.; Sidney, Steve; Lima, Joao; Lewis, Cora E.

    2013-01-01

    Sedentary screen time (watching TV or using a computer) predicts cardiovascular outcomes independently from moderate and vigorous physical activity and could impact left ventricular structure and function through the adverse consequences of sedentary behavior. Purpose To determine whether sedentary screen time is associated with measures of left ventricular structure and function. Methods The Coronary Artery Risk Development in Young Adults (CARDIA) Study measured screen time by questionnaire and left ventricular structure and function by echocardiography in 2,854 black and white participants, aged 43–55 years, in 2010–2011. Generalized linear models evaluated cross-sectional trends for echocardiography measures across higher categories of screen time and adjusting for demographics, smoking, alcohol, and physical activity. Further models adjusted for potential intermediate factors (blood pressure, antihypertensive medication use, diabetes, and body mass index (BMI). Results The relationship between screen time and left ventricular mass(LVM) differed in blacks vs. whites. Among whites, higher screen time was associated with larger LVM (P<0.001), after adjustment for height, demographics, and lifestyle variables. Associations between screen time and LVM persisted when adjusting for blood pressure, antihypertensive medication use, and diabetes (P=0.008) but not with additional adjustment for BMI (P=0.503). Similar relationships were observed for screen time with LVM indexed to height2.7, relative wall thickness, and mass-to-volume ratio. Screen time was not associated with left ventricular structure among blacks or left ventricular function in either race group. Conclusions Sedentary screen time is associated with greater LVM in white adults and this relationship was largely explained by higher overall adiposity. The lack of association in blacks supports a potential qualitative difference in the cardiovascular consequences of sedentary screen-based behavior. PMID:23863618

  3. Children and Their Changing Media Environment: A European Comparative Study.

    ERIC Educational Resources Information Center

    Livingstone, Sonia, Ed.; Bovill, Moira, Ed.

    Integrating broadcasting, video, computing, games, and the Internet, the domestic television screen is being transformed into the site of a multimedia culture. To address questions about the meaning and uses of such new media, this volume brings together work by researchers in 12 countries--Belgium, Denmark, Finland, France, Germany, the United…

  4. Design and evaluation of high-volume fly ash (HVFA) concrete mixes, report A : evaluation of HVFA cementitious paste and concrete mixtures.

    DOT National Transportation Integrated Search

    2012-10-01

    In the Paste Screening Study, 25 combinations of five Type I/II portland cements : and five Class C fly ashes commonly used in Missouri were tested in paste form with no : chemical or powder additives. Testing procedures included semi-adiabatic calor...

  5. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    PubMed

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with median follow-up of 8·16 years (IQR 7·56-8·56). 187 (3%) of 7155 screened participants were diagnosed with 196 screen-detected lung cancers, and another 34 (<1%; 19 [56%] in the first year after screening, and 15 [44%] in the second year after screening) were diagnosed with 35 interval cancers. For the three screening rounds combined, with a 2-year follow-up, sensitivity was 84·6% (95% CI 79·6-89·2), specificity was 98·6% (95% CI 98·5-98·8), positive predictive value was 40·4% (95% CI 35·9-44·7), and negative predictive value was 99·8% (95% CI 99·8-99·9). Retrospective assessment of the last screening CT and clinical CT in 34 patients with interval cancer showed that interval cancers were not visible in 12 (35%) cases. In the remaining cases, cancers were visible when retrospectively assessed, but were not diagnosed because of radiological detection and interpretation errors (17 [50%]), misclassification by the protocol (two [6%]), participant non-compliance (two [6%]), and non-adherence to protocol (one [3%]). Compared with screen-detected cancers, interval cancers were diagnosed at more advanced stages (29 [83%] of 35 interval cancers vs 44 [22%] of 196 screen-detected cancers diagnosed in stage III or IV; p<0·0001), were more often small-cell carcinomas (seven [20%] vs eight [4%]; p=0·003) and less often adenocarcinomas (nine [26%] vs 102 [52%]; p=0·005). Lung cancer screening in the NELSON trial yielded high specificity and sensitivity, with only a small number of interval cancers. The results of this study could be used to improve screening algorithms, and reduce the number of missed cancers. Zorgonderzoek Nederland Medische Wetenschappen and Koningin Wilhelmina Fonds. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Development of an Automated Microfluidic Reaction Platform for Multidimensional Screening: Reaction Discovery Employing Bicyclo[3.2.1]octanoid Scaffolds

    PubMed Central

    Goodell, John R.; McMullen, Jonathan P.; Zaborenko, Nikolay; Maloney, Jason R.; Ho, Chuan-Xing; Jensen, Klavs F.; Porco, John A.

    2010-01-01

    An automated, silicon-based microreactor system has been developed for rapid, low-volume, multidimensional reaction screening. Use of the microfluidic platform to identify transformations of densely functionalized bicyclo[3.2.1]octanoid scaffolds will be described. PMID:20560568

  7. THE HYDROCARBON SPILL SCREENING MODEL (HSSM), VOLUME 2: THEORETICAL BACKGROUND AND SOURCE CODES

    EPA Science Inventory

    A screening model for subsurface release of a nonaqueous phase liquid which is less dense than water (LNAPL) is presented. The model conceptualizes the release as consisting of 1) vertical transport from near the surface to the capillary fringe, 2) radial spreading of an LNAPL l...

  8. Miniaturization of High-Throughput Epigenetic Methyltransferase Assays with Acoustic Liquid Handling.

    PubMed

    Edwards, Bonnie; Lesnick, John; Wang, Jing; Tang, Nga; Peters, Carl

    2016-02-01

    Epigenetics continues to emerge as an important target class for drug discovery and cancer research. As programs scale to evaluate many new targets related to epigenetic expression, new tools and techniques are required to enable efficient and reproducible high-throughput epigenetic screening. Assay miniaturization increases screening throughput and reduces operating costs. Echo liquid handlers can transfer compounds, samples, reagents, and beads in submicroliter volumes to high-density assay formats using only acoustic energy-no contact or tips required. This eliminates tip costs and reduces the risk of reagent carryover. In this study, we demonstrate the miniaturization of a methyltransferase assay using Echo liquid handlers and two different assay technologies: AlphaLISA from PerkinElmer and EPIgeneous HTRF from Cisbio. © 2015 Society for Laboratory Automation and Screening.

  9. Satisfactory visualization rates of standard cardiac views at 18 to 22 weeks' gestation using spatiotemporal image correlation.

    PubMed

    Cohen, Leeber; Mangers, Kristie; Grobman, William A; Platt, Lawrence D

    2009-12-01

    The purpose of this study was to determine the frequency with which 3 standard screening views of the fetal heart (4-chamber, left ventricular outflow tract [LVOT], and right ventricular outflow tract [RVOT]) can be obtained satisfactorily with the spatiotemporal image correlation (STIC) technique. A prospective study of 111 patients undergoing anatomic surveys at 18 to 22 weeks was performed. Two ultrasound machines with fetal cardiac settings were used. The best volume set that could be obtained from each patient during a 45-minute examination was graded by 2 sonologists with regard to whether the 4-chamber, LVOT, and RVOT images were satisfactory for screening. All 3 views were judged satisfactory for screening in most patients: 1 sonologist graded the views as satisfactory in 70% of the patients, whereas the other found the views to be satisfactory in 83%. The position of the placenta did not alter the probability of achieving a satisfactory view, but a fetus in the spine anterior position was associated with a significantly lower probability that the views were regarded as satisfactory for screening (odds ratio, 0.28; 95% confidence interval, 0.09-0.70; P < .05). This study suggests that STIC may assist with screening for cardiac anomalies at 18 to 22 weeks' gestation.

  10. Trials and projects on cervical cancer and human papillomavirus prevention in sub-Saharan Africa.

    PubMed

    Adefuye, Peter O; Broutet, Nathalie J; de Sanjosé, Silvia; Denny, Lynette A

    2013-12-29

    Cervical cancer is the leading cause of cancer morbidity and mortality in women in sub-Saharan Africa (SSA), accounting for about 50,000 deaths annually. Until recently, cytology was the gold standard for screening and prevention of cervical cancer. This method of screening has not been successful in SSA due to a lack of human, financial and material resources and poor health care infrastructure. It is estimated that less than 5% of at risk women have ever being screened. In the past two decades alternative approaches to cytology for cervical cancer screening have been evaluated in low- and medium-income countries. Visual inspection with acetic acid (VIA) and/or Lugol's iodine (VILI) have been shown to have adequate sensitivity, although low specificity, in a number of cross-sectional research and demonstration projects. Visual inspection methods require minimal resources, are technologically accessible, and are feasible for screening for precancerous lesions. Linking screening with VIA/VILI to treatment with cryotherapy may enable screening and treatment to take place in one visit, but this is likely to result in large numbers of women being subjected to unnecessary treatment. A number of studies have shown that cryotherapy is not associated with significant side effects or complications and is well tolerated. Creating the infrastructure for screening of older women is considered desirable, despite the limitations of visual inspection methods as screening tests. Understanding the role of human papillomavirus (HPV) infection in the etiology of cervical cancer and the discovery of HPV rapid test kits, as well as the development of vaccines against the HPV oncogenic types, have created new opportunities for prevention of cervical cancer. Trials and projects have established (and are still ongoing) the feasibility of using these molecular tests for screening. The ultimate in prevention method is primary prevention, offered by the advent of prophylactic vaccines against the most important oncogenic types, namely HPV16 and 18. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Sub-Saharan Africa Region" Vaccine Volume 31, Supplement 5, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Current Realities of Delivering Mammography Services in the Community: Do Challenges with Staffing and Scheduling Exist?

    PubMed Central

    D'Orsi, Carl; Tu, Shin-Ping; Nakano, Connie; Carney, Patricia A.; Abraham, Linn A.; Taplin, Stephen H.; Hendrick, R. Edward; Cutter, Gary R.; Berns, Eric; Barlow, William E.; Elmore, Joann G.

    2011-01-01

    PURPOSE To evaluate the current (2001–2002) capacity of community-based mammography facilities to deliver screening and diagnostic services in the United States. MATERIALS AND METHODS Institutional review board approvals and patient consent were obtained. A mailed survey was sent to 53 eligible mammography facilities in three states (Washington, New Hampshire, and Colorado). Survey questions assessed equipment and staffing availability, as well as appointment waiting times for screening and diagnostic mammography services. Criterion-related content and construct validity were obtained first by means of a national advisory committee of academic, scientific, and clinical colleagues in mammography that reviewed literature on existing surveys and second by pilot testing a series of draft surveys among community mammography facilities not inclusive of the study facilities. The final survey results were independently double entered into a relational database with programmed data checks. The data were sent encrypted by means of file transfer protocol to a central analytical center at Group Health Cooperative. A two-sided P value with α = .05 was considered to show statistical significance in all analyses. RESULTS Forty-five of 53 eligible mammography facilities (85%) returned the survey. Shortages of radiologists relative to the mammographic volume were found in 44% of mammography facilities overall, with shortages of radiologists higher in not-for-profit versus for-profit facilities (60% vs 28% reported). Shortages of Mammography Quality Standards Act–qualified technologists were reported by 20% of facilities, with 46% reporting some level of difficulty in maintaining qualified technologists. Waiting times for diagnostic mammography ranged from less than 1 week to 4 weeks, with 85% performed within 1 week. Waiting times for screening mammography ranged from less than 1 week to 8 weeks, with 59% performed between 1 week and 4 weeks. Waiting times for both diagnostic and screening services were two to three times higher in high-volume compared with low-volume facilities. CONCLUSION Survey results show shortages of radiologists and certified mammography technologists. PMID:15798153

  12. Exploratory Study of the Potential Effects of Exposure to Sonic Boom on Human Health. Volume 2. Epidemiological Study.

    DTIC Science & Technology

    1986-06-01

    were retained from the original source. The undesired data lines in both shortened population files were then manually deleted through full-screen...Prenatal Visits 00-99 00-blank 88-not on certificate 99-unknown Apgar Score: 161-162 1 min. 00-10, 88, 99 99-entry >10 88-not on record 00=blank 163

  13. The electrostatic persistence length of polymers beyond the OSF limit.

    PubMed

    Everaers, R; Milchev, A; Yamakov, V

    2002-05-01

    We use large-scale Monte Carlo simulations to test scaling theories for the electrostatic persistence length l(e) of isolated, uniformly charged polymers with Debye-Hückel intrachain interactions in the limit where the screening length kappa(-1) exceeds the intrinsic persistence length of the chains. Our simulations cover a significantly larger part of the parameter space than previous studies. We observe no significant deviations from the prediction l(e) proportional to kappa(-2) by Khokhlov and Khachaturian which is based on applying the Odijk-Skolnick-Fixman theories of electrostatic bending rigidity and electrostatically excluded volume to the stretched de Gennes-Pincus-Velasco-Brochard polyelectrolyte blob chain. A linear or sublinear dependence of the persistence length on the screening length can be ruled out. We show that previous results pointing into this direction are due to a combination of excluded-volume and finite chain length effects. The paper emphasizes the role of scaling arguments in the development of useful representations for experimental and simulation data.

  14. Establishing a cost-per-result of laboratory-based, reflex Cryptococcal antigenaemia screening (CrAg) in HIV+ patients with CD4 counts less than 100 cells/μl using a Lateral Flow Assay (LFA) at a typical busy CD4 laboratory in South Africa.

    PubMed

    Cassim, Naseem; Schnippel, Kathryn; Coetzee, Lindi Marie; Glencross, Deborah Kim

    2017-01-01

    Cryptococcal meningitis is a major cause of mortality and morbidity in countries with high HIV prevalence, primarily affecting patients whose CD4 are < = 100 cells/μl. Routine Cryptococcal Antigen (CrAg) screening is thus recommended in the South African HIV treatment guidelines for all patients with CD4 counts < = 100 cells/μl, followed by pre-emptive anti-fungal therapy where CrAg results are positive. A laboratory-based reflexed CrAg screening approach, using a Lateral Flow Assay (LFA) on remnant EDTA CD4 blood samples, was piloted at three CD4 laboratories. This study aimed to assess the cost-per-result of laboratory-based reflexed CrAg screening at one pilot CD4 referral laboratory. CD4 test volumes from 2014 were extracted to estimate percentage of CD4 < = 100 cells/μl. Daily average volumes were derived, assuming 12 months per/year and 21.73 working days per/month. Costing analyses were undertaken using Microsoft Excel and Stata with a provider prospective. The cost-per-result was estimated using a bottom-up method, inclusive of test kits and consumables (reagents), laboratory equipment and technical effort costs. The ZAR/$ exchange of 14.696/$1 was used, where applicable. One-way sensitivity analyses on the cost-per-result were conducted for possible error rates (3%- 8%, reductions or increases in reagent costs as well as test volumes (ranging from -60% to +60%). The pilot CD4 laboratory performed 267000 CD4 tests in 2014; ~ 9.3% (27500) reported CD4< = 100 cells/μl, equivalent to 106 CrAg tests performed daily. A batch of 30-tests could be performed in 1.6 hours, including preparation and analysis time. A cost-per-result of $4.28 was reported, with reagents contributing $3.11 (72.8%), while technical effort and laboratory equipment overheads contributed $1.17 (27.2%) and $0.03 (<1%) respectively. One-way sensitivity analyses including increasing or decreasing test volumes by 60% revealed a cost-per-result range of $3.84 to $6.03. A cost-per-result of $4.28 was established in a typical CD4 service laboratory to enable local budgetary cost projections and programmatic cost-effectiveness modelling. Varying reagent costs linked to currency exchange and varying test volumes in different levels of service can lead to varying cost-per-test and technical effort to manage workload, with an inverse relationship of higher costs expected at lower volumes of tests.

  15. Results of a Community-based, Randomized Study Comparing a Clear Liquid Diet With a Low-residue Diet Using a Magnesium Citrate Preparation for Screening and Surveillance Colonoscopies.

    PubMed

    Thukral, Chandrashekhar; Tewani, Sumeet K; Lake, Adam J; Shiels, Aaron J; Geissler, Kathy; Popejoy, Sara; Stafford, Megan; Vicari, Joseph J

    2017-11-03

    Current bowel preparations for colonoscopy include a clear liquid diet (CLD) along with consumption of a laxative. This dietary restriction along with large volume bowel preparations are barriers to compliance and willingness among patients in scheduling screening examinations. The aim of our study was to compare the efficacy and tolerability of a low-volume split dose magnesium citrate bowel preparation in patients on a low-residue diet (LRD) with those on a CLD. In this single center, single blinded, randomized controlled trial, patients scheduled for outpatient colonoscopies were assigned to either a CLD or a LRD 1 day before the examination. Both groups received a split dose magnesium citrate preparation. The quality of the preparation was rated using the Boston Bowel Preparation Scale (BBPS). Patient satisfaction and side effects were evaluated using a questionnaire. We were unable to detect a significant difference in the BBPS scores between the LRD and CLD groups (P=0.581). A significantly higher percentage of patients in the LRD group rated the diet as easy compared with the CLD group (P<0.001). Satisfaction scores were significantly higher in the LRD group, compared with the CLD group (P<0.001). The side effect profiles of both arms were similar. There was no significant difference between LRD and CLD in patients using a magnesium citrate bowel preparation for screening and surveillance colonoscopies. Patient satisfaction scores were higher with a LRD compared with a CLD. We believe the LRD should be the recommended diet in patients using a standard bowel preparation for screening and surveillance colonoscopy.

  16. Acoustic Sample Deposition MALDI-MS (ASD-MALDI-MS): A Novel Process Flow for Quality Control Screening of Compound Libraries.

    PubMed

    Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M

    2016-02-01

    In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.

  17. Comparison between different colon cleansing products for screening colonoscopy. A noninferiority trial in population-based screening programs in Italy.

    PubMed

    Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio

    2016-03-01

    The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions  + 1.9 %, 95 % confidence interval [CI]  - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions  - 0.2 %, 95 %CI  - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay.

    PubMed

    Liu, Wen-Wen; Zhu, Ying; Fang, Qun

    2017-06-20

    There is a great demand to measure protein-ligand interactions in rapid and low cost way. Here, we developed a microfluidic droplet-based thermal shift assay (dTSA) system for high-throughput screening of small-molecule protein ligands. The system is composed of a nanoliter droplet array chip, a microfluidic droplet robot, and a real-time fluorescence detection system. Total 324 assays could be performed in parallel in a single chip with an 18 × 18 droplet array. The consumption of dTSA for each protein or ligand sample was only 5 nL (femtomole scale), which is significantly reduced by over 3 orders of magnitude compared with those in 96- or 384-well plate-based systems. We also observed the implementation of TSA in nanoliter droplet format could substantially improve assay precision with relative standard deviation (RSD) of 0.2% (n = 50), which can be ascribed to the enhanced thermal conduction in small volume reactors. The dTSA system was optimized by studying the effect of droplet volumes, as well as protein and fluorescent dye (SYPRO Orange) concentrations. To demonstrate its potential in drug discovery, we applied the dTSA system in screening inhibitors of human thrombin with a commercial library containing 100 different small molecule compounds, and two inhibitors were successfully identified and confirmed.

  19. A High-Throughput Fluorescence-Based Assay System for Appetite-Regulating Gene and Drug Screening

    PubMed Central

    Shimada, Yasuhito; Hirano, Minoru; Nishimura, Yuhei; Tanaka, Toshio

    2012-01-01

    The increasing number of people suffering from metabolic syndrome and obesity is becoming a serious problem not only in developed countries, but also in developing countries. However, there are few agents currently approved for the treatment of obesity. Those that are available are mainly appetite suppressants and gastrointestinal fat blockers. We have developed a simple and rapid method for the measurement of the feeding volume of Danio rerio (zebrafish). This assay can be used to screen appetite suppressants and enhancers. In this study, zebrafish were fed viable paramecia that were fluorescently-labeled, and feeding volume was measured using a 96-well microplate reader. Gene expression analysis of brain-derived neurotrophic factor (bdnf), knockdown of appetite-regulating genes (neuropeptide Y, preproinsulin, melanocortin 4 receptor, agouti related protein, and cannabinoid receptor 1), and the administration of clinical appetite suppressants (fluoxetine, sibutramine, mazindol, phentermine, and rimonabant) revealed the similarity among mechanisms regulating appetite in zebrafish and mammals. In combination with behavioral analysis, we were able to evaluate adverse effects on locomotor activities from gene knockdown and chemical treatments. In conclusion, we have developed an assay that uses zebrafish, which can be applied to high-throughput screening and target gene discovery for appetite suppressants and enhancers. PMID:23300705

  20. 40 CFR 799.9365 - TSCA combined repeated dose toxicity study with the reproduction/developmental toxicity screening...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the control and the top dose group for observation of reversibility, persistence or delayed occurrence... toxicity. (2) Dosage. (i) Generally, at least three test groups and a control group should be used. If... administering the test substance, the control group should receive the vehicle in the highest volume used. (ii...

  1. 40 CFR 799.9365 - TSCA combined repeated dose toxicity study with the reproduction/developmental toxicity screening...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the control and the top dose group for observation of reversibility, persistence or delayed occurrence... toxicity. (2) Dosage. (i) Generally, at least three test groups and a control group should be used. If... administering the test substance, the control group should receive the vehicle in the highest volume used. (ii...

  2. 40 CFR 799.9365 - TSCA combined repeated dose toxicity study with the reproduction/developmental toxicity screening...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the control and the top dose group for observation of reversibility, persistence or delayed occurrence... toxicity. (2) Dosage. (i) Generally, at least three test groups and a control group should be used. If... administering the test substance, the control group should receive the vehicle in the highest volume used. (ii...

  3. 40 CFR 799.9365 - TSCA combined repeated dose toxicity study with the reproduction/developmental toxicity screening...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the control and the top dose group for observation of reversibility, persistence or delayed occurrence... toxicity. (2) Dosage. (i) Generally, at least three test groups and a control group should be used. If... administering the test substance, the control group should receive the vehicle in the highest volume used. (ii...

  4. 40 CFR 799.9365 - TSCA combined repeated dose toxicity study with the reproduction/developmental toxicity screening...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the control and the top dose group for observation of reversibility, persistence or delayed occurrence... toxicity. (2) Dosage. (i) Generally, at least three test groups and a control group should be used. If... administering the test substance, the control group should receive the vehicle in the highest volume used. (ii...

  5. The relationship between limit of Dysphagia and average volume per swallow in patients with Parkinson's disease.

    PubMed

    Belo, Luciana Rodrigues; Gomes, Nathália Angelina Costa; Coriolano, Maria das Graças Wanderley de Sales; de Souza, Elizabete Santos; Moura, Danielle Albuquerque Alves; Asano, Amdore Guescel; Lins, Otávio Gomes

    2014-08-01

    The goal of this study was to obtain the limit of dysphagia and the average volume per swallow in patients with mild to moderate Parkinson's disease (PD) but without swallowing complaints and in normal subjects, and to investigate the relationship between them. We hypothesize there is a direct relationship between these two measurements. The study included 10 patients with idiopathic PD and 10 age-matched normal controls. Surface electromyography was recorded over the suprahyoid muscle group. The limit of dysphagia was obtained by offering increasing volumes of water until piecemeal deglutition occurred. The average volume per swallow was calculated by dividing the time taken by the number of swallows used to drink 100 ml of water. The PD group showed a significantly lower dysphagia limit and lower average volume per swallow. There was a significantly moderate direct correlation and association between the two measurements. About half of the PD patients had an abnormally low dysphagia limit and average volume per swallow, although none had spontaneously related swallowing problems. Both measurements may be used as a quick objective screening test for the early identification of swallowing alterations that may lead to dysphagia in PD patients, but the determination of the average volume per swallow is much quicker and simpler.

  6. TO PURGE OR NOT TO PURGE? VOC CONCENTRATION CHANGES DURING LINE VOLUME PURGING

    EPA Science Inventory

    Soil vapor surveys are commonly used as a screening technique to delineate volatile organic compound (VOC) contaminant plumes and provide information for soil sampling plans. Traditionally, three purge volumes of vapor are removed before a sample is collected. One facet of this s...

  7. Why Can't Johnny Read? The Abell Report. Volume 23, No.7

    ERIC Educational Resources Information Center

    Jacobson, Joan

    2010-01-01

    Baltimore's school-based vision-screening program may be leaving thousands of children with uncorrected eyesight problems. Vision screening in public schools is essential for students to learn, especially when low-income children face a high rate of eyesight problems and have poor access to health care. Left undetected and uncorrected, vision…

  8. Longitudinal follow-up study of smoking-induced emphysema progression in low-dose CT screening of lung cancer

    NASA Astrophysics Data System (ADS)

    Suzuki, H.; Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, Masahiro; Moriyama, N.

    2014-03-01

    Chronic obstructive pulmonary disease is a major public health problem that is predicted to be third leading cause of death in 2030. Although spirometry is traditionally used to quantify emphysema progression, it is difficult to detect the loss of pulmonary function by emphysema in early stage, and to assess the susceptibility to smoking. This study presents quantification method of smoking-induced emphysema progression based on annual changes of low attenuation volume (LAV) by each lung lobe acquired from low-dose CT images in lung cancer screening. The method consists of three steps. First, lung lobes are segmented using extracted interlobar fissures by enhancement filter based on fourdimensional curvature. Second, LAV of each lung lobe is segmented. Finally, smoking-induced emphysema progression is assessed by statistical analysis of the annual changes represented by linear regression of LAV percentage in each lung lobe. This method was applied to 140 participants in lung cancer CT screening for six years. The results showed that LAV progressions of nonsmokers, past smokers, and current smokers are different in terms of pack-year and smoking cessation duration. This study demonstrates effectiveness in diagnosis and prognosis of early emphysema in lung cancer CT screening.

  9. Navy Fuel Composition and Screening Tool (FCAST) v.2.5

    DTIC Science & Technology

    2014-07-18

    a major impediment to certification of these fuels as Fit-For- Purpose (FFP) for the U.S. Navy. A method whereby a candidate fuel could be rapidly...the U.S. Navy. A method whereby a candidate fuel could be rapidly screened for many FFP properties, using a minimal volume (< 1 mL), would overcome...mobility fuels with new alternative fuels, regardless of their source or processing methods . The Fuel Composition and Screening Tool (FCAST) was

  10. A Novel, Low-Volume Method for Organ Culture of Embryonic Kidneys That Allows Development of Cortico-Medullary Anatomical Organization

    PubMed Central

    Sebinger, David D. R.; Unbekandt, Mathieu; Ganeva, Veronika V.; Ofenbauer, Andreas; Werner, Carsten; Davies, Jamie A.

    2010-01-01

    Here, we present a novel method for culturing kidneys in low volumes of medium that offers more organotypic development compared to conventional methods. Organ culture is a powerful technique for studying renal development. It recapitulates many aspects of early development very well, but the established techniques have some disadvantages: in particular, they require relatively large volumes (1–3 mls) of culture medium, which can make high-throughput screens expensive, they require porous (filter) substrates which are difficult to modify chemically, and the organs produced do not achieve good cortico-medullary zonation. Here, we present a technique of growing kidney rudiments in very low volumes of medium–around 85 microliters–using silicone chambers. In this system, kidneys grow directly on glass, grow larger than in conventional culture and develop a clear anatomical cortico-medullary zonation with extended loops of Henle. PMID:20479933

  11. Cell dispensing in low-volume range with the immediate drop-on-demand technology (I-DOT).

    PubMed

    Schober, Lena; Büttner, Evy; Laske, Christopher; Traube, Andrea; Brode, Tobias; Traube, Andreas Florian; Bauernhansl, Thomas

    2015-04-01

    Handling and dosing of cells comprise the most critical step in the microfabrication of cell-based assay systems for screening and toxicity testing. Therefore, the immediate drop-on-demand technology (I-DOT) was developed to provide a flexible noncontact liquid handling system enabling dispensing of cells and liquid without the risk of cross-contamination down to a precise volume in the nanoliter range. Liquid is dispensed from a source plate within nozzles at the bottom by a short compressed air pulse that is given through a quick release valve into the well, thus exceeding the capillary pressure in the nozzle. Droplets of a defined volume can be spotted directly onto microplates or other cell culture devices. We present a study on the performance and biological impact of this technology by applying the cell line MCF-7, human fibroblasts, and human mesenchymal stem cells (hMSCs). For all cell types tested, viability after dispensing is comparable to the control and exhibits similar proliferation rates in the absence of apoptotic cells, and the differentiation potential of hMSCs is not impaired. The immediate drop-on-demand technology enables accurate cell dosage and offers promising potential for single-cell applications. © 2014 Society for Laboratory Automation and Screening.

  12. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling

    NASA Astrophysics Data System (ADS)

    McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation.

  13. Acquisition/expulsion system for earth orbital propulsion system study. Volume 5: Earth storable design

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A comprehensive analysis and parametric design effort was conducted under the earth-storable phase of the program. Passive Acquisition/expulsion system concepts were evaluated for a reusable Orbital Maneuvering System (OMS) application. The passive surface tension technique for providing gas free liquid on demand was superior to other propellant acquisition methods. Systems using fine mesh screens can provide the requisite stability and satisfy OMS mission requirements. Both fine mesh screen liner and trap systems were given detailed consideration in the parametric design, and trap systems were selected for this particular application. These systems are compatible with the 100- to 500-manned mission reuse requirements.

  14. Colorectal cancer screening: Estimated future colonoscopy need and current volume and capacity.

    PubMed

    Joseph, Djenaba A; Meester, Reinier G S; Zauber, Ann G; Manninen, Diane L; Winges, Linda; Dong, Fred B; Peaker, Brandy; van Ballegooijen, Marjolein

    2016-08-15

    In 2014, a national campaign was launched to increase colorectal cancer (CRC) screening rates in the United States to 80% by 2018; it is unknown whether there is sufficient colonoscopy capacity to reach this goal. This study estimated the number of colonoscopies needed to screen 80% of the eligible population with fecal immunochemical testing (FIT) or colonoscopy and determined whether there was sufficient colonoscopy capacity to meet the need. The Microsimulation Screening Analysis-Colon model was used to simulate CRC screening test use in the United States (2014-2040); the implementation of a national screening program in 2014 with FIT or colonoscopy with 80% participation was assumed. The 2012 Survey of Endoscopic Capacity (SECAP) estimated the number of colonoscopies that were performed and the number that could be performed. If a national screening program started in 2014, by 2024, approximately 47 million FIT procedures and 5.1 million colonoscopies would be needed annually to screen the eligible population with a program using FIT as the primary screening test; approximately 11 to 13 million colonoscopies would be needed annually to screen the eligible population with a colonoscopy-only screening program. According to the SECAP survey, an estimated 15 million colonoscopies were performed in 2012, and an additional 10.5 million colonoscopies could be performed. The estimated colonoscopy capacity is sufficient to screen 80% of the eligible US population with FIT, colonoscopy, or a mix of tests. Future analyses should take into account the geographic distribution of colonoscopy capacity. Cancer 2016;122:2479-86. © 2016 American Cancer Society. © 2016 American Cancer Society.

  15. Formation and evolution of bubbly screens in confined oscillating bubbly liquids.

    PubMed

    Shklyaev, Sergey; Straube, Arthur V

    2010-01-01

    We consider the dynamics of dilute monodisperse bubbly liquid confined by two plane solid walls and subject to small-amplitude high-frequency oscillations normal to the walls. The initial state corresponds to the uniform distribution of bubbles and motionless liquid. The period of external driving is assumed much smaller than typical relaxation times for a single bubble but larger than the period of volume eigenoscillations. The time-averaged description accounting for the two-way coupling between the liquid and the bubbles is applied. We show that the model predicts accumulation of bubbles in thin sheets parallel to the walls. These singular structures, which are formally characterized by infinitely thin width and infinitely high concentration, are referred to as bubbly screens. The formation of a bubbly screen is described analytically in terms of a self-similar solution, which is in agreement with numerical simulations. We study the evolution of bubbly screens and detect a one-dimensional stationary state, which is shown to be unconditionally unstable.

  16. Formation and evolution of bubbly screens in confined oscillating bubbly liquids

    NASA Astrophysics Data System (ADS)

    Shklyaev, Sergey; Straube, Arthur V.

    2010-01-01

    We consider the dynamics of dilute monodisperse bubbly liquid confined by two plane solid walls and subject to small-amplitude high-frequency oscillations normal to the walls. The initial state corresponds to the uniform distribution of bubbles and motionless liquid. The period of external driving is assumed much smaller than typical relaxation times for a single bubble but larger than the period of volume eigenoscillations. The time-averaged description accounting for the two-way coupling between the liquid and the bubbles is applied. We show that the model predicts accumulation of bubbles in thin sheets parallel to the walls. These singular structures, which are formally characterized by infinitely thin width and infinitely high concentration, are referred to as bubbly screens. The formation of a bubbly screen is described analytically in terms of a self-similar solution, which is in agreement with numerical simulations. We study the evolution of bubbly screens and detect a one-dimensional stationary state, which is shown to be unconditionally unstable.

  17. Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification

    PubMed Central

    Oh, Kyudam; Pak, Nikita; Saunders, D. Curtis; Conrardy, Christina; Landers, James P.; Tong, Suxiang; Forest, Craig R.

    2016-01-01

    Sensitive identification of the etiology of viral diseases is key to implementing appropriate prevention and treatment. The gold standard for virus identification is the polymerase chain reaction (PCR), a technique that allows for highly specific and sensitive detection of pathogens by exponentially amplifying a specific region of DNA from as little as a single copy through thermocycling a biochemical cocktail. Today, molecular biology laboratories use commercial instruments that operate in 0.5–2 h/analysis using reaction volumes of 5–50 μL contained within polymer tubes or chambers. Towards reducing this volume and maintaining performance, we present a semi-quantitative, systematic experimental study of how PCR yield is affected by tube/chamber substrate, surface-area-to-volume ratio (SA:V), and passivation methods. We perform PCR experiments using traditional PCR tubes as well as using disposable polymer microchips with 1 μL reaction volumes thermocycled using water baths. We report the first oil encapsulation microfluidic PCR method without fluid flow and its application to the first microfluidic amplification of Epstein Barr virus using consensus degenerate primers, a powerful and broad PCR method to screen for both known and novel members of a viral family. The limit of detection is measured as 140 starting copies of DNA from a starting concentration of 3×105 copies/mL, regarded as an accepted sensitivity threshold for diagnostic purposes, and reaction specificity was improved as compared to conventional methods. Also notable, these experiments were conducted with conventional reagent concentrations, rather than commonly spiked enzyme and/or template mixtures. This experimental study of the effects of substrate, SA:V, and passivation, together with sensitive and specific microfluidic PCR with consensus degenerate primers represent advances towards lower cost and higher throughput pathogen screening. PMID:23080522

  18. Configuration evaluation and criteria plan. Volume 2: Evaluation critera plan (preliminary). Space Transportation Main Engine (STME) configuration study

    NASA Technical Reports Server (NTRS)

    Bair, E. K.

    1986-01-01

    The unbiased selection of the Space Transportation Main Engine (STME) configuration requires that the candidate engines be evaluated against a predetermined set of criteria which must be properly weighted to emphasize critical requirements defined prior to the actual evaluation. The evaluation and selection process involves the following functions: (1) determining if a configuration can satisfy basic STME requirements (yes/no); (2) defining the evaluation criteria; (3) selecting the criteria relative importance or weighting; (4) determining the weighting sensitivities; and (5) establishing a baseline for engine evaluation. The criteria weighting and sensitivities are cost related and are based on mission models and vehicle requirements. The evaluation process is used as a coarse screen to determine the candidate engines for the parametric studies and as a fine screen to determine concept(s) for conceptual design. The criteria used for the coarse and fine screen evaluation process is shown. The coarse screen process involves verifying that the candidate engines can meet the yes/no screening requirements and a semi-subjective quantitative evaluation. The fine screen engines have to meet all of the yes/no screening gates and are then subjected to a detailed evaluation or assessment using the quantitative cost evaluation processes. The option exists for re-cycling a concept through the quantitative portion of the screening and allows for some degree of optimization. The basic vehicle is a two stage LOX/HC, LOX/LH2 parallel burn vehicle capable of placing 150,000 lbs in low Earth orbit (LEO).

  19. Medical Surveillance Monthly Report (MSMR). Volume 23, Number 2, February 2016

    DTIC Science & Technology

    2016-05-06

    the past 20 years.3 Th e expansion of the cur- rent epidemic that began in the early 2000s was primarily attributable to increased cases among men...disease screening. In the early 20th century, it was estimated that 5% of Army enlistees had evidence of some type of venereal disease.11 Wasserman...conjunction with early screening dur- ing World War II, led to near eradica- tion of syphilis among active duty Army soldiers.11 Screening for syphilis in

  20. Functional Cardiorespiratory Toxicity Screening of Candidate Antiparasitic Drugs and Antidotes for Chemical Poisons. Study of the Effects of Drugs Upon the Cardiovascular and Respiratory Systems

    DTIC Science & Technology

    1988-06-01

    and Hamilton, 1971). This lecithin -contain- ing substance keeps alveoli from collapsing and allows larger Increases in lung volume to occur without a...1979; Caldwell and Nash, 1977). Use of mefioqulne following chloroquine administration where resistance to chioroquine therapy might arise is a distinct

  1. Improved survival in cystic fibrosis patients diagnosed by newborn screening compared to a historical cohort from the same centre.

    PubMed

    Dijk, F Nicole; McKay, Karen; Barzi, Federica; Gaskin, Kevin J; Fitzgerald, Dominic A

    2011-12-01

    Newborn screening (NBS) for cystic fibrosis (CF) is associated with improved early nutritional outcomes and improved spirometry in children. The aim of this study was to determine whether early diagnosis and treatment of CF with NBS in New South Wales in 1981 led to better clinical outcomes and survival into early adulthood. Retrospective observational study comprising two original cohorts born in the 3 years before ('non-screened cohort', n=57) and after ('screened'; n=60) the introduction of NBS. Patient records were assessed at transfer from paediatric to adult care by age 19 years and survival was documented to age 25 years. Non-screened patients (n=38) when compared with screened patients (n=41) had a higher rate and lower age of Pseudomonas aeruginosa acquisition at age 18 years (p ≤ 0.01). Height, weight and body mass index (BMI) z scores (all p<0.01) and forced expiratory volume in 1 s (FEV(1))% were better in the screened group (n=41) (difference: 16.7 ± 6.4%; p=0.01) compared to non-screened (n=38) subjects on transfer to adult care. Each 1% increase in FEV(1)% was associated with a 3% (95% CI 1% to 5%; p=0.001) decrease in risk of death and each 1.0 kg/m(2) increase in BMI contributed to a 44% (95% CI 31% to 55%; p<0.001) decrease in risk of death. This accumulated in a significant survival difference at age 25 years (25 vs 13 deaths or lung transplants; p=0.01). NBS for CF leads to better lung function, nutritional status and improved survival in screened patients in early adulthood.

  2. Multi-Layered TiO2 Films towards Enhancement of Escherichia coli Inactivation

    PubMed Central

    Yoriya, Sorachon; Chumphu, Angkana; Pookmanee, Pusit; Laithong, Wreerat; Thepa, Sirichai; Songprakorp, Roongrojana

    2016-01-01

    Crystalline TiO2 has shown its great photocatalytic properties in bacterial inactivation. This work presents a design fabrication of low-cost, layered TiO2 films assembled reactors and a study of their performance for a better understanding to elucidate the photocatalytic effect on inactivation of E. coli in water. The ability to reduce the number of bacteria in water samples for the layered TiO2 composing reactors has been investigated as a function of time, while varying the parameters of light sources, initial concentration of bacteria, and ratios of TiO2 film area and volume of water. Herein, the layered TiO2 films have been fabricated on the glass plates by thermal spray coating prior to screen printing, allowing a good adhesion of the films. Surface topology and crystallographic phase of TiO2 for the screen-printed active layer have been characterized, resulting in the ratio of anatase:rutile being 80:20. Under exposure to sunlight and a given condition employed in this study, the optimized film area:water volume of 1:2.62 has shown a significant ability to reduce the E. coli cells in water samples. The ratio of surface area of photocatalytic active base to volume of water medium is believed to play a predominant role facilitating the cells inactivation. The kinetic rate of inactivation and its behavior are also described in terms of adsorption of reaction species at different contact times. PMID:28773930

  3. Estimating the harms and benefits of prostate cancer screening as used in common practice versus recommended good practice: A microsimulation screening analysis.

    PubMed

    Carlsson, Sigrid V; de Carvalho, Tiago M; Roobol, Monique J; Hugosson, Jonas; Auvinen, Anssi; Kwiatkowski, Maciej; Villers, Arnauld; Zappa, Marco; Nelen, Vera; Páez, Alvaro; Eastham, James A; Lilja, Hans; de Koning, Harry J; Vickers, Andrew J; Heijnsdijk, Eveline A M

    2016-11-15

    Prostate-specific antigen (PSA) screening and concomitant treatment can be implemented in several ways. The authors investigated how the net benefit of PSA screening varies between common practice versus "good practice." Microsimulation screening analysis (MISCAN) was used to evaluate the effect on quality-adjusted life-years (QALYs) if 4 recommendations were followed: limited screening in older men, selective biopsy in men with elevated PSA, active surveillance for low-risk tumors, and treatment preferentially delivered at high-volume centers. Outcomes were compared with a base model in which annual screening started at ages 55 to 69 years and were simulated using data from the European Randomized Study of Screening for Prostate Cancer. In terms of QALYs gained compared with no screening, for 1000 screened men who were followed over their lifetime, recommended good practice led to 73 life-years (LYs) and 74 QALYs gained compared with 73 LYs and 56 QALYs for the base model. In contrast, common practice led to 78 LYs gained but only 19 QALYs gained, for a greater than 75% relative reduction in QALYs gained from unadjusted LYs gained. The poor outcomes for common practice were influenced predominantly by the use of aggressive treatment for men with low-risk disease, and PSA testing in older men also strongly reduced potential QALY gains. Commonly used PSA screening and treatment practices are associated with little net benefit. Following a few straightforward clinical recommendations, particularly greater use of active surveillance for low-risk disease and reducing screening in older men, would lead to an almost 4-fold increase in the net benefit of prostate cancer screening. Cancer 2016;122:3386-3393. © 2016 American Cancer Society. © 2016 American Cancer Society.

  4. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 4: Graphical status display

    NASA Technical Reports Server (NTRS)

    Mckee, James W.

    1990-01-01

    This volume (4 of 4) contains the description, structured flow charts, prints of the graphical displays, and source code to generate the displays for the AMPS graphical status system. The function of these displays is to present to the manager of the AMPS system a graphical status display with the hot boxes that allow the manager to get more detailed status on selected portions of the AMPS system. The development of the graphical displays is divided into two processes; the creation of the screen images and storage of them in files on the computer, and the running of the status program which uses the screen images.

  5. High-Throughput Method for Automated Colony and Cell Counting by Digital Image Analysis Based on Edge Detection

    PubMed Central

    Choudhry, Priya

    2016-01-01

    Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849

  6. Sniffin' Sticks and olfactory system imaging in patients with Kallmann syndrome.

    PubMed

    Ottaviano, Giancarlo; Cantone, Elena; D'Errico, Arianna; Salvalaggio, Alessandro; Citton, Valentina; Scarpa, Bruno; Favaro, Angela; Sinisi, Antonio Agostino; Liuzzi, Raffaele; Bonanni, Guglielmo; Di Salle, Francesco; Elefante, Andrea; Manara, Renzo; Staffieri, Alberto; Martini, Alessandro; Brunetti, Arturo

    2015-09-01

    The relationship between olfactory function, rhinencephalon and forebrain changes in Kallmann syndrome (KS) have not been adequately investigated. We evaluated a large cohort of male KS patients using Sniffin' Sticks and MRI in order to study olfactory bulb (OB) volume, olfactory sulcus (OS) depth, cortical thickness close to the OS, and olfactory phenotype. Olfaction was assessed administering Sniffin' Sticks®, in 38 KS patients and 17 controls (by means of Screening 12 test®). All subjects underwent magnetic resonance imaging (MRI) to study OB volume, sulcus depth, and cortical thickness. Compared to controls, KS patients showed smaller OB volume (p<0.0001), reduced sulcus depth (p<0.0001), and thicker cortex in the region close to the OS (p<0.0001). Anosmic KS patients had smaller OB than controls and hyposmic KS patients; there was no difference between hyposmic KS patients and controls. OB volume correlated with Sniffin' Sticks score (r = 0.64; p < 0.001), OS depth (p<0.0001) and, inversely, with cortical thickness changes (p<0.0001). Sniffin' Sticks showed an inverse correlation with cortical thickness (r = -0.5; p<0.0001) and a trend toward a statistically significant correlation with OS depth. The present study provides further evidence of the strict relationship between olfaction and OB volume. The strong correlation between OB volume and the overlying cortical changes highlights the key role of rhinencephalon in forebrain embryogenesis. © 2015 ARS-AAOA, LLC.

  7. Stimulation of Single Isolated Adult Ventricular Myocytes within a Low Volume Using a Planar Microelectrode Array

    PubMed Central

    Klauke, Norbert; Smith, Godfrey L.; Cooper, Jon

    2003-01-01

    Microchannels (40-μm wide, 10-μm high, 10-mm long, 70-μm pitch) were patterned in the silicone elastomer, polydimethylsiloxane on a microscope coverslip base. Integrated within each microchamber were individually addressable stimulation electrodes (40-μm wide, 20-μm long, 100-nm thick) and a common central pseudo-reference electrode (60-μm wide, 500-μm long, 100-nm thick). Isolated rabbit ventricular myocytes were introduced into the chamber by micropipetting and subsequently capped with a layer of mineral oil, thus creating limited volumes of saline around individual myocytes that could be varied from 5 nL to 100 pL. Excitation contraction coupling was studied by monitoring myocyte shortening and intracellular Ca2+ transients (using Fluo-3 fluorescence) . The amplitude of stimulated myocyte shortening and Ca2+ transients remained constant for 90 min in the larger volume (5 nL) configuration, although the shortening (but not the Ca2+ transient) amplitude gradually decreased to 20% of control within 60 min in the low volume (100 pL) arrangement. These studies indicate a lower limit for the extracellular volume required to stimulate isolated adult cardiac myocytes. Whereas this arrangement could be used to create a screening assay for drugs, individual microchannels (100 pL) can also be used to study the effects of limited extracellular volume on the contractility of single cardiac myocytes. PMID:12944291

  8. Lubiprostone plus PEG electrolytes versus placebo plus PEG electrolytes for outpatient colonoscopy preparation: a randomized, double-blind placebo-controlled trial.

    PubMed

    Sofi, Aijaz A; Nawras, Ali T; Pai, Chetan; Samuels, Qiana; Silverman, Ann L

    2015-01-01

    Bowel preparation using large volume of polyethylene glycol (PEG) solutions is often poorly tolerated. Therefore, there are ongoing efforts to develop an alternative bowel cleansing regimen that should be equally effective and better tolerated. The aim of this study was to assess the efficacy of lubiprostone (versus placebo) plus PEG as a bowel cleansing preparation for colonoscopy. Our study was a randomized, double-blind placebo-controlled design. Patients scheduled for screening colonoscopy were randomized 1:1 to lubiprostone (group 1) or placebo (group 2) plus 1 gallon of PEG. The primary endpoints were patient's tolerability and endoscopist's evaluation of the preparation quality. The secondary endpoint was to determine any reduction in the amount of PEG consumed in the lubiprostone group compared with the placebo group. One hundred twenty-three patients completed the study and were included in the analysis. There was no difference in overall cleanliness. The volume of PEG was similar in both the groups. The volume of PEG approached significance as a predictor of improved score for both the groups (P = 0.054). Lubiprostone plus PEG was similar to placebo plus PEG in colon cleansing and volume of PEG consumed. The volume of PEG consumed showed a trend toward improving the quality of the colon cleansing.

  9. Image-fusion of MR spectroscopic images for treatment planning of gliomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang Jenghwa; Thakur, Sunitha; Perera, Gerard

    2006-01-15

    {sup 1}H magnetic resonance spectroscopic imaging (MRSI) can improve the accuracy of target delineation for gliomas, but it lacks the anatomic resolution needed for image fusion. This paper presents a simple protocol for fusing simulation computer tomography (CT) and MRSI images for glioma intensity-modulated radiotherapy (IMRT), including a retrospective study of 12 patients. Each patient first underwent whole-brain axial fluid-attenuated-inversion-recovery (FLAIR) MRI (3 mm slice thickness, no spacing), followed by three-dimensional (3D) MRSI measurements (TE/TR: 144/1000 ms) of a user-specified volume encompassing the extent of the tumor. The nominal voxel size of MRSI ranged from 8x8x10 mm{sup 3} to 12x12x10more » mm{sup 3}. A system was developed to grade the tumor using the choline-to-creatine (Cho/Cr) ratios from each MRSI voxel. The merged MRSI images were then generated by replacing the Cho/Cr value of each MRSI voxel with intensities according to the Cho/Cr grades, and resampling the poorer-resolution Cho/Cr map into the higher-resolution FLAIR image space. The FUNCTOOL processing software was also used to create the screen-dumped MRSI images in which these data were overlaid with each FLAIR MRI image. The screen-dumped MRSI images were manually translated and fused with the FLAIR MRI images. Since the merged MRSI images were intrinsically fused with the FLAIR MRI images, they were also registered with the screen-dumped MRSI images. The position of the MRSI volume on the merged MRSI images was compared with that of the screen-dumped MRSI images and was shifted until agreement was within a predetermined tolerance. Three clinical target volumes (CTVs) were then contoured on the FLAIR MRI images corresponding to the Cho/Cr grades. Finally, the FLAIR MRI images were fused with the simulation CT images using a mutual-information algorithm, yielding an IMRT plan that simultaneously delivers three different dose levels to the three CTVs. The image-fusion protocol was tested on 12 (six high-grade and six low-grade) glioma patients. The average agreement of the MRSI volume position on the screen-dumped MRSI images and the merged MRSI images was 0.29 mm with a standard deviation of 0.07 mm. Of all the voxels with Cho/Cr grade one or above, the distribution of Cho/Cr grade was found to correlate with the glioma grade from pathologic finding and is consistent with literature results indicating Cho/Cr elevation as a marker for malignancy. In conclusion, an image-fusion protocol was developed that successfully incorporates MRSI information into the IMRT treatment plan for glioma.« less

  10. Vision Algorithms Catch Defects in Screen Displays

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Andrew Watson, a senior scientist at Ames Research Center, developed a tool called the Spatial Standard Observer (SSO), which models human vision for use in robotic applications. Redmond, Washington-based Radiant Zemax LLC licensed the technology from NASA and combined it with its imaging colorimeter system, creating a powerful tool that high-volume manufacturers of flat-panel displays use to catch defects in screens.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurley, D.F.; Whitehouse, J.M.

    A dedicated low-flow groundwater sample collection system was designed for implementation in a post-closure ACL monitoring program at the Yaworski Lagoon NPL site in Canterbury, Connecticut. The system includes dedicated bladder pumps with intake ports located in the screened interval of the monitoring wells. This sampling technique was implemented in the spring of 1993. The system was designed to simultaneously obtain samples directly from the screened interval of nested wells in three distinct water bearing zones. Sample collection is begun upon stabilization of field parameters. Other than line volume, no prior purging of the well is required. It was foundmore » that dedicated low-flow sampling from the screened interval provides a method of representative sample collection without the bias of suspended solids introduced by traditional techniques of pumping and bailing. Analytical data indicate that measured chemical constituents are representative of groundwater migrating through the screened interval. Upon implementation of the low-flow monitoring system, analytical results exhibited a decrease in concentrations of some organic compounds and metals. The system has also proven to be a cost effective alternative to pumping and bailing which generate large volumes of purge water requiring containment and disposal.« less

  12. Audit feedback on reading performance of screening mammograms: An international comparison.

    PubMed

    Hofvind, S; Bennett, R L; Brisson, J; Lee, W; Pelletier, E; Flugelman, A; Geller, B

    2016-09-01

    Providing feedback to mammography radiologists and facilities may improve interpretive performance. We conducted a web-based survey to investigate how and why such feedback is undertaken and used in mammographic screening programmes. The survey was sent to representatives in 30 International Cancer Screening Network member countries where mammographic screening is offered. Seventeen programmes in 14 countries responded to the survey. Audit feedback was aimed at readers in 14 programmes, and facilities in 12 programmes. Monitoring quality assurance was the most common purpose of audit feedback. Screening volume, recall rate, and rate of screen-detected cancers were typically reported performance measures. Audit reports were commonly provided annually, but more frequently when target guidelines were not reached. The purpose, target audience, performance measures included, form and frequency of the audit feedback varied amongst mammographic screening programmes. These variations may provide a basis for those developing and improving such programmes. © The Author(s) 2016.

  13. Newsletter for Asian and Middle Eastern Languages on Computer, Volume 1, Numbers 3 & 4.

    ERIC Educational Resources Information Center

    Meadow, Anthony, Ed.

    1986-01-01

    Volume 1, numbers 3 and 4, of the newsletter on the use of non-Western languages with computers contains the following articles: "Reversing the Screen under MS/PC-DOS" (Dan Brink); "Comments on Diacritics Using Wordstar, etc. and CP/M Software for Non-Western Languages" (Michael Broschat); "Carving Tibetan in Silicon: A…

  14. Capillary blood islet autoantibody screening for identifying pre-type 1 diabetes in the general population: design and initial results of the Fr1da study

    PubMed Central

    Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G

    2016-01-01

    Introduction Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Methods and analysis Children aged 2–5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Results Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Discussion Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. Ethics dissemination The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). PMID:27194320

  15. Capillary blood islet autoantibody screening for identifying pre-type 1 diabetes in the general population: design and initial results of the Fr1da study.

    PubMed

    Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G

    2016-05-18

    Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Children aged 2-5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Conceptual design of thermal energy storage systems for near term electric utility applications. Volume 1: Screening of concepts

    NASA Technical Reports Server (NTRS)

    Hausz, W.; Berkowitz, B. J.; Hare, R. C.

    1978-01-01

    Over forty thermal energy storage (TES) concepts gathered from the literature and personal contacts were studied for their suitability for the electric utility application of storing energy off-peak discharge during peak hours. Twelve selections were derived from the concepts for screening; they used as storage media high temperature water (HTW), hot oil, molten salts, and packed beds of solids such as rock. HTW required pressure containment by prestressed cast-iron or concrete vessels, or lined underground cavities. Both steam generation from storage and feedwater heating from storage were studied. Four choices were made for further study during the project. Economic comparison by electric utility standard cost practices, and near-term availability (low technical risk) were principal criteria but suitability for utility use, conservation potential, and environmental hazards were considered.

  17. Production of arrays of chemically distinct nanolitre plugs via repeated splitting in microfluidic devices.

    PubMed

    Adamson, David N; Mustafi, Debarshi; Zhang, John X J; Zheng, Bo; Ismagilov, Rustem F

    2006-09-01

    This paper reports a method for the production of arrays of nanolitre plugs with distinct chemical compositions. One of the primary constraints on the use of plug-based microfluidics for large scale biological screening is the difficulty of fabricating arrays of chemically distinct plugs on the nanolitre scale. Here, using microfluidic devices with several T-junctions linked in series, a single input array of large (approximately 320 nL) plugs was split to produce 16 output arrays of smaller (approximately 20 nL) plugs; the composition and configuration of these arrays were identical to that of the input. This paper shows how the passive break-up of plugs in T-junction microchannel geometries can be used to produce a set of smaller-volume output arrays useful for chemical screening from a single large-volume array. A simple theoretical description is presented to describe splitting as a function of the Capillary number, the capillary pressure, the total pressure difference across the channel, and the geometric fluidic resistance. By accounting for these considerations, plug coalescence and plug-plug contamination can be eliminated from the splitting process and the symmetry of splitting can be preserved. Furthermore, single-outlet splitting devices were implemented with both valve- and volume-based methods for coordinating the release of output arrays. Arrays of plugs containing commercial sparse matrix screens were obtained from the presented splitting method and these arrays were used in protein crystallization trials. The techniques presented in this paper may facilitate the implementation of high-throughput chemical and biological screening.

  18. [Weak evidence concerning sedentary lifestyle and its association with cardio-metabolic illness among young people. "Junk food" and late evenings in front of the screen part of a complex connection].

    PubMed

    Fröberg, Andreas; Raustorp, Anders

    2015-06-16

    During recent decades there has been a rapidly growing interest in youths' sedentary behaviour and its association with cardio-metabolic health. Currently there is little-to-no evidence for a cross-sectional and longitudinal association between volume and pattern (bouts and breaks) of objectively measured sedentary behavior and body weight in youth. Likewise, there is little-to-no evidence for a cross-sectional association between volume and pattern of objectively measured sedentary behavior and other markers for cardio-metabolic risk in youth. However, there is sufficient evidence for a cross-sectional and longitudinal association between screen-time and body weight and blood pressure and blood lipids. Furthermore, there is evidence for a cross-sectional association between youths' screen-time and clustered metabolic risk and insulin resistance. Overall, the level of evidence was low and, therefore, caution is required when interpreting the results.

  19. In situ DMSO hydration measurements of HTS compound libraries.

    PubMed

    Ellson, R; Stearns, R; Mutz, M; Brown, C; Browning, B; Harris, D; Qureshi, S; Shieh, J; Wold, D

    2005-09-01

    Compounds used in high throughput screening (HTS) are typically dissolved in DMSO. These solutions are stored automation-friendly racks of wells or tubes. DMSO is hygroscopic and quickly absorbs water from the atmosphere. When present in DMSO compound solutions, water can accelerate degradation and precipitation. Understanding DMSO hydration in an HTS compound library can improve storage and screening methods by managing the impact of water on compound stability. A non-destructive, acoustic method compatible with HTS has been developed to measure water content in DMSO solutions. Performance of this acoustic method was compared with an optical technique and found to be in good agreement. The accuracy and precision of acoustic measurements was shown to be under 3% over the tested range of DMSO solutions (0% to 35% water by volume) and insensitive to the presence of HTS compounds at typical storage concentrations. Time course studies of hydration for wells in 384-well and 1536-well microplates were performed. Well geometry, fluid volume, well position and atmospheric conditions were all factors in hydration rate. High rates of hydration were seen in lower-volume fills, higher-density multi-well plates and when there was a large differential between the humidity of the lab and the water content of the DMSO. For example, a 1536-well microplate filled with 2microL of 100% DMSO exposed for one hour to a laboratory environment with approximately 40% relative humidity will absorb over 6% water by volume. Understanding DMSO hydration rates as well as the ability to reverse library hydration are important steps towards managing stability and availability of compound libraries.

  20. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model.

    PubMed

    Kozinszky, Zoltan; Surányi, Andrea; Péics, Hajnalka; Molnár, András; Pál, Attila

    2015-08-01

    The aim of this study was to determine the utility of a new mathematical model in volumetric assessment of the placenta using 2-D ultrasound. Placental volumetry was performed in a prospective cross-sectional survey by virtual organ computer-aided analysis (VOCAL) with the help of a shell-off method in 346 uncomplicated pregnancies according to STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Furthermore, placental thickness, length and height were measured with the 2-D technique to estimate placental volume based on the mathematical formula for the volume of "the shell of the spherical sector." Fetal size was also assessed by 2-D sonography. The placental volumes measured by 2-D and 3-D techniques had a correlation of 0.86. In the first trimester, the correlation was 0.82, and later during pregnancy, it was 0.86. Placental volumetry using "the circle-shaped shell of the spherical sector" mathematical model with 2-D ultrasound technique may be introduced into everyday practice to screen for placental volume deviations associated with adverse pregnancy outcome. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. An update on airborne contact dermatitis.

    PubMed

    Huygens, S; Goossens, A

    2001-01-01

    This review is an update of 2 previously published articles on airborne contact dermatoses. Because reports in the literature often omit the term 'airborne', 18 volumes of Contact Dermatitis (April 1991-June 2000), 8 volumes of the American Journal of Contact Dermatitis (1992 1999) and 4 volumes of La Lettre du Gerda (1996-1999) were screened, and the cases cited were classified as to history, lesion locations, sensitization sources, and other factors. Reports on airborne dermatitis are increasingly being published, sometimes in relation to specific occupational areas.

  2. Evaluation of Dried Urine Spot Method to Screen Cotinine among Tobacco Dependents: An Exploratory Study.

    PubMed

    Jain, Raka; Quraishi, Rizwana; Verma, Arpita

    2017-01-01

    Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.

  3. Lung cancers diagnosed at annual CT screening: volume doubling times.

    PubMed

    Henschke, Claudia I; Yankelevitz, David F; Yip, Rowena; Reeves, Anthony P; Farooqi, Ali; Xu, Dongming; Smith, James P; Libby, Daniel M; Pasmantier, Mark W; Miettinen, Olli S

    2012-05-01

    To empirically address the distribution of the volume doubling time (VDT) of lung cancers diagnosed in repeat annual rounds of computed tomographic (CT) screening in the International Early Lung Cancer Action Program (I-ELCAP), first and foremost with respect to rates of tumor growth but also in terms of cell types. All CT screenings in I-ELCAP from 1993 to 2009 were performed according to HIPAA-compliant protocols approved by the institutional review boards of the collaborating institutions. All instances of first diagnosis of primary lung cancer after a negative screening result 7-18 months earlier were identified, with symptom-prompted diagnoses included. Lesion diameter was calculated by using the measured length and width of each cancer at the time when the nodule was first identified for further work-up and at the time of the most recent prior screening, 7-18 months earlier. The length and width were measured a second time for each cancer, and the geometric mean of the two calculated diameters was used to calculate the VDT. The χ(2) statistic was used to compare the VDT distributions. The median VDT for 111 cancers was 98 days (interquartile range, 108). For 56 (50%) cancers it was less than 100 days, and for three (3%) cancers it was more than 400 days. Adenocarcinoma was the most frequent cell type (50%), followed by squamous cell carcinoma (19%), small cell carcinoma (19%), and others (12%). Lung cancers manifesting as subsolid nodules had significantly longer VDTs than those manifesting as solid nodules (P < .0001). Lung cancers diagnosed in annual repeat rounds of CT screening, as manifest by the VDT and cell-type distributions, are similar to those diagnosed in the absence of screening.

  4. Methodology for enabling high-throughput simultaneous saccharification and fermentation screening of yeast using solid biomass as a substrate.

    PubMed

    Elliston, Adam; Wood, Ian P; Soucouri, Marie J; Tantale, Rachelle J; Dicks, Jo; Roberts, Ian N; Waldron, Keith W

    2015-01-01

    High-throughput (HTP) screening is becoming an increasingly useful tool for collating biological data which would otherwise require the employment of excessive resources. Second generation biofuel production is one such process. HTP screening allows the investigation of large sample sets to be undertaken with increased speed and cost effectiveness. This paper outlines a methodology that will enable solid lignocellulosic substrates to be hydrolyzed and fermented at a 96-well plate scale, facilitating HTP screening of ethanol production, whilst maintaining repeatability similar to that achieved at a larger scale. The results showed that utilizing sheets of biomass of consistent density (handbills), for paper, and slurries of pretreated biomass that could be pipetted allowed standardized and accurate transfers to 96-well plates to be achieved (±3.1 and 1.7%, respectively). Processing these substrates by simultaneous saccharification and fermentation (SSF) at various volumes showed no significant difference on final ethanol yields, either at standard shake flask (200 mL), universal bottle (10 mL) or 96-well plate (1 mL) scales. Substrate concentrations of up to 10% (w/v) were trialed successfully for SSFs at 1 mL volume. The methodology was successfully tested by showing the effects of steam explosion pretreatment on both oilseed rape and wheat straws. This methodology could be used to replace large shake flask reactions with comparatively fast 96-well plate SSF assays allowing for HTP experimentation. Additionally this method is compatible with a number of standardized assay techniques such as simple colorimetric, High-performance liquid chromatography (HPLC) and Nuclear magnetic resonance (NMR) spectroscopy. Furthermore this research has practical uses in the biorefining of biomass substrates for second generation biofuels and novel biobased chemicals by allowing HTP SSF screening, which should allow selected samples to be scaled up or studied in more detail.

  5. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling.

    PubMed

    McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Multi-views Fusion CNN for Left Ventricular Volumes Estimation on Cardiac MR Images.

    PubMed

    Luo, Gongning; Dong, Suyu; Wang, Kuanquan; Zuo, Wangmeng; Cao, Shaodong; Zhang, Henggui

    2017-10-13

    Left ventricular (LV) volumes estimation is a critical procedure for cardiac disease diagnosis. The objective of this paper is to address direct LV volumes prediction task. In this paper, we propose a direct volumes prediction method based on the end-to-end deep convolutional neural networks (CNN). We study the end-to-end LV volumes prediction method in items of the data preprocessing, networks structure, and multi-views fusion strategy. The main contributions of this paper are the following aspects. First, we propose a new data preprocessing method on cardiac magnetic resonance (CMR). Second, we propose a new networks structure for end-to-end LV volumes estimation. Third, we explore the representational capacity of different slices, and propose a fusion strategy to improve the prediction accuracy. The evaluation results show that the proposed method outperforms other state-of-the-art LV volumes estimation methods on the open accessible benchmark datasets. The clinical indexes derived from the predicted volumes agree well with the ground truth (EDV: R=0.974, RMSE=9.6ml; ESV: R=0.976, RMSE=7.1ml; EF: R=0.828, RMSE =4.71%). Experimental results prove that the proposed method has high accuracy and efficiency on LV volumes prediction task. The proposed method not only has application potential for cardiac diseases screening for large-scale CMR data, but also can be extended to other medical image research fields.

  7. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    PubMed

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  8. The value of the 4-day headdown bedrest model for screening countermeasures

    NASA Technical Reports Server (NTRS)

    Vernikos, J.; Keil, L.; Ertl, A. C.; Wade, C. E.; Greenleaf, J. E.; Ohara, D.; Ludwig, D.

    1992-01-01

    In order to evaluate the benefits of periodic exposure to the +G(z) vector as a countermeasure to the physiological responses to minus 6 degree head down bedrest (HDT), we considered a two-tiered approach: (a) to use 4 days HDT as a quick and inexpensive means of screening countermeasures, (b) to use a 60 day HDT to validate the most promising candidates. The approach and results of a 4 day study are described here. Methods: Nine males were admitted to our Human Research Facility for one ambulatory control day followed by 4 days HDT and were released on the next day after completion of a peak oxygen consumption test (VO(sub 2 peak)). A battery of tests was selected and standardized to evaluate the known early effects of HDT on plasma volume, early bone markers, orthostatic tolerance, physical performance, and fluid and electrolytes and their hormone regulation. Fluid sodium (Na) and potassium (K) intake and output in the urine were monitored throughout. Plasma volume was determined with a modified Evans Blue method and orthostatic tolerance with a 60 degree head-up tilt test for 30 minutes - both of which were determined on the ambulatory control day and on day 4 of HDT. Immediately after completion of the tilt test subjects were returned to the minus 6 degree position until the next morning when a VO(sub 2 peak) (horizontal ergometer) was done. This was compared to a similar control test determined on 2 separate occasions before subject admission. Results: Four hours after going HDT produced significant decreases (p less than 0.05) in the circulating concentration of fluid and electrolyte regulating hormones. Plasma volume, orthostatic tolerance and VO(sub 2 peak) changed significantly after 4 days HDT. There was also the expected natriuresis on day 1 of HDT but no significant diuresis. The consistency of the pre-bedrest VO(sub 2 peak) tilt tests and plasma volumes was remarkable. Conclusions: The 4 day HDT model seems highly promising for screening a variety of countermeasures alone and in combination before validating their benefits in extended bedrest or flight experiments.

  9. Changes in the Hiring Process: New Actors, New Practices, and New Challenges. Final Report. Volume I: Findings and Implications [and] Volume II: Appendices.

    ERIC Educational Resources Information Center

    Kogan, Deborah; And Others

    Trends in the recruitment and hiring practices of U.S. private sector firms were examined by analyzing data from the following: a literature review; telephone discussions with representatives of 13 key national labor market intermediaries (outplacement, career management, job search, screening, and staffing service firms); telephone discussions…

  10. Is breast compression associated with breast cancer detection and other early performance measures in a population-based breast cancer screening program?

    PubMed

    Moshina, Nataliia; Sebuødegård, Sofie; Hofvind, Solveig

    2017-06-01

    We aimed to investigate early performance measures in a population-based breast cancer screening program stratified by compression force and pressure at the time of mammographic screening examination. Early performance measures included recall rate, rates of screen-detected and interval breast cancers, positive predictive value of recall (PPV), sensitivity, specificity, and histopathologic characteristics of screen-detected and interval breast cancers. Information on 261,641 mammographic examinations from 93,444 subsequently screened women was used for analyses. The study period was 2007-2015. Compression force and pressure were categorized using tertiles as low, medium, or high. χ 2 test, t tests, and test for trend were used to examine differences between early performance measures across categories of compression force and pressure. We applied generalized estimating equations to identify the odds ratios (OR) of screen-detected or interval breast cancer associated with compression force and pressure, adjusting for fibroglandular and/or breast volume and age. The recall rate decreased, while PPV and specificity increased with increasing compression force (p for trend <0.05 for all). The recall rate increased, while rate of screen-detected cancer, PPV, sensitivity, and specificity decreased with increasing compression pressure (p for trend <0.05 for all). High compression pressure was associated with higher odds of interval breast cancer compared with low compression pressure (1.89; 95% CI 1.43-2.48). High compression force and low compression pressure were associated with more favorable early performance measures in the screening program.

  11. Screening Magnetic Resonance Imaging-Based Prediction Model for Assessing Immediate Therapeutic Response to Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids.

    PubMed

    Kim, Young-sun; Lim, Hyo Keun; Park, Min Jung; Rhim, Hyunchul; Jung, Sin-Ho; Sohn, Insuk; Kim, Tae-Joong; Keserci, Bilgin

    2016-01-01

    The aim of this study was to fit and validate screening magnetic resonance imaging (MRI)-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation. Informed consent from all subjects was obtained for our institutional review board-approved study. A total of 240 symptomatic uterine fibroids (mean diameter, 6.9 cm) in 152 women (mean age, 43.3 years) treated with MR-HIFU ablation were retrospectively analyzed (160 fibroids for training, 80 fibroids for validation). Screening MRI parameters (subcutaneous fat thickness [mm], x1; relative peak enhancement [%] in semiquantitative perfusion MRI, x2; T2 signal intensity ratio of fibroid to skeletal muscle, x3) were used to fit prediction models with regard to ablation efficiency (nonperfused volume/treatment cell volume, y1) and ablation quality (grade 1-5, poor to excellent, y2), respectively, using the generalized estimating equation method. Cutoff values for achievement of treatment intent (efficiency >1.0; quality grade 4/5) were determined based on receiver operating characteristic curve analysis. Prediction performances were validated by calculating positive and negative predictive values. Generalized estimating equation analyses yielded models of y1 = 2.2637 - 0.0415x1 - 0.0011x2 - 0.0772x3 and y2 = 6.8148 - 0.1070x1 - 0.0050x2 - 0.2163x3. Cutoff values were 1.312 for ablation efficiency (area under the curve, 0.7236; sensitivity, 0.6882; specificity, 0.6866) and 4.019 for ablation quality (0.8794; 0.7156; 0.9020). Positive and negative predictive values were 0.917 and 0.500 for ablation efficiency and 0.978 and 0.600 for ablation quality, respectively. Screening MRI-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MR-HIFU ablation were fitted and validated, which may reduce the risk of unsuccessful treatment.

  12. [Implementation of performance indicators in the Czech Breast Cancer Screening Programme -  results of the regular monitoring].

    PubMed

    Májek, O; Bartoňková, H; Daneš, J; Skovajsová, M; Dušek, L

    2014-01-01

    The Czech organised breast cancer screening programme was initiated in 2002. Collection of data on screening mammography examinations, subsequent diagnostic procedures, and final dia-gnosis is an indispensable part of the programme. Data collection is obligatory for all accredited centres, in accordance with regulations issued by the Czech Ministry of Health. This contribution aims to demonstrate the recent results of quality monitoring of the accredited centres. Quality indicators, whose definition complies with international standards, involve the women's participation, the volume of performed examinations, the accuracy of screening mammography, the use of preoperative diagnostics, and the proportion of early detected tumours. Our evaluation documents a continuous improvement in quality of the Czech mammography screening programme, which is thereby in full agreement with international recommendations on quality assurance.

  13. Is Erythrocyte Protoporphyrin a Better Single Screening Test for Iron Deficiency Compared to Hemoglobin or Mean Cell Volume in Children and Women?

    PubMed

    Mei, Zuguo; Flores-Ayala, Rafael C; Grummer-Strawn, Laurence M; Brittenham, Gary M

    2017-05-31

    Hemoglobin (Hb), mean cell volume (MCV), and erythrocyte protoporphyrin (EP) are commonly used to screen for iron deficiency (ID), but systematic evaluation of the sensitivity and specificity of these tests is limited. The objective of this study is to determine the sensitivity and specificity of Hb, MCV, and EP measurements in screening for ID in preschool children, non-pregnant women 15-49 years of age, and pregnant women. Data from the National Health and Nutrition Examination Surveys (NHANES) (NHANES 2003-2006: n = 861, children three to five years of age; n = 3112, non-pregnant women 15 to 49 years of age. NHANES 1999-2006: n = 1150, pregnant women) were examined for this purpose. Children or women with blood lead ≥10 µg/dL or C-reactive protein (CRP) >5.0 mg/L were excluded. ID was defined as total body iron stores <0 mg/kg body weight, calculated from the ratio of soluble transferrin receptor (sTfR) to serum ferritin (SF). The receiver operating characteristic (ROC) curve was used to characterize the sensitivity and specificity of Hb, MCV, and EP measurements in screening for ID. In detecting ID in children three to five years of age, EP (Area under the Curve (AUC) 0.80) was superior to Hb (AUC 0.62) ( p < 0.01) but not statistically different from MCV (AUC 0.73). In women, EP and Hb were comparable (non-pregnant AUC 0.86 and 0.84, respectively; pregnant 0.77 and 0.74, respectively), and both were better than MCV (non-pregnant AUC 0.80; pregnant 0.70) ( p < 0.01). We concluded that the sensitivity and specificity of EP in screening for ID were consistently superior to or at least as effective as those of Hb and MCV in each population examined. For children three to five years of age, EP screening for ID was significantly better than Hb and similar to MCV. For both non-pregnant and pregnant women, the performance of EP and Hb were comparable; both were significantly superior to MCV.

  14. Comparative analysis of upper airway volume with lateral cephalograms and cone-beam computed tomography.

    PubMed

    Feng, Xin; Li, Gang; Qu, Zhenyu; Liu, Lin; Näsström, Karin; Shi, Xie-Qi

    2015-02-01

    In this study, we aimed to evaluate the adenoidal nasopharyngeal ratio (ANR) on lateral cephalograms by assessing upper airway volumes using cone-beam computed tomography (CBCT) images as the validation method. Fifty-five patients were included in the study, and it was essential that the lateral cephalograms and CBCT images taken at their examinations were not more than 1 week apart. There were 32 subjects in group A (age ≤15 years) and 23 subjects in group B (age >15 years). The ANR was measured on the lateral cephalograms. The area and volumetric measurements of the nasopharynx and the total upper airway were obtained from CBCT images. Repeated measurements of the ANR and airway volume were performed on 10 subjects by 2 observers. Group A had a higher correlation (r = -0.78) between the ANR and the nasopharynx volume than did group B (r = -0.57). The ANR had a weak correlation with the total upper airway volume (group A, r = -0.48; group B, r = -0.32). Both measurements made on lateral cephalograms and CBCT were highly reproducible in terms of intraobserver and interobserver agreement. Based on our results, the measurement of the ANR on lateral cephalograms can be used as an initial screening method to estimate the nasopharynx volumes of younger patients (age ≤15 years). Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  15. A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views

    PubMed Central

    Veronese, Paola; Bogana, Gianna; Cerutti, Alessia; Yeo, Lami; Romero, Roberto; Gervasi, Maria Teresa

    2016-01-01

    Objective To evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views. Methods In this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates for standard fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated. Results One or more STIC volumes (n=463 total) were obtained in 246 patients. A single STIC volume per patient was analyzed using the FINE method. In normal cases, FINE was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 76-100% of cases; 2) VIS-Assistance® in 96-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 96-100% of cases. Conclusion FINE applied to STIC volumes can successfully generate nine standard fetal echocardiography views in 96-100% of cases in the second and third trimesters. This suggests that the technology can be used as a method to screen for congenital heart disease. PMID:27309391

  16. Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management

    DTIC Science & Technology

    2015-08-01

    Micrometer ml Milliliter MS Mass Spectrometry MW Molecular Weight MΩ Mega-ohm NAS Naval Air Station 6 NASNI Naval Air Station North Island...feasibility studies. ..........42 Table 5-2 Compounds screened in the laboratory for IS2 sampling ......................................44 Table 5-3 Mass ...concentration data is derived directly from the mass of analyte recovered from the sorbent cartridge and the known volume of water processed. This

  17. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    NASA Astrophysics Data System (ADS)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  18. Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

    PubMed

    Funaki, Ayumu; Ohkubo, Masaki; Wada, Shinichi; Murao, Kohei; Matsumoto, Toru; Niizuma, Shinji

    2012-07-01

    With the wide dissemination of computed tomography (CT) screening for lung cancer, measuring the nodule volume accurately with computer-aided volumetry software is increasingly important. Many studies for determining the accuracy of volumetry software have been performed using a phantom with artificial nodules. These phantom studies are limited, however, in their ability to reproduce the nodules both accurately and in the variety of sizes and densities required. Therefore, we propose a new approach of using computer-simulated nodules based on the point spread function measured in a CT system. The validity of the proposed method was confirmed by the excellent agreement obtained between computer-simulated nodules and phantom nodules regarding the volume measurements. A practical clinical evaluation of the accuracy of volumetry software was achieved by adding simulated nodules onto clinical lung images, including noise and artifacts. The tested volumetry software was revealed to be accurate within an error of 20 % for nodules >5 mm and with the difference between nodule density and background (lung) (CT value) being 400-600 HU. Such a detailed analysis can provide clinically useful information on the use of volumetry software in CT screening for lung cancer. We concluded that the proposed method is effective for evaluating the performance of computer-aided volumetry software.

  19. Development of a New Arterial-Line Filter Design Using Computational Fluid Dynamics Analysis

    PubMed Central

    Herbst, Daniel P.; Najm, Hani K.

    2012-01-01

    Abstract: Arterial-line filters used during extracorporeal circulation continue to rely on the physical properties of a wetted micropore and reductions in blood flow velocity to affect air separation from the circulating blood volume. Although problems associated with air embolism during cardiac surgery persist, a number of investigators have concluded that further improvements in filtration are needed to enhance air removal during cardiopulmonary bypass procedures. This article reviews theoretical principles of micropore filter technology and outlines the development of a new arterial-line filter concept using computational fluid dynamics analysis. Manufacturer-supplied data of a micropore screen and experimental results taken from an ex vivo test circuit were used to define the inputs needed for numerical modeling of a new filter design. Flow patterns, pressure distributions, and velocity profiles predicted with computational fluid dynamics softwarewere used to inform decisions on model refinements and how to achieve initial design goals of ≤225 mL prime volume and ≤500 cm2 of screen surface area. Predictions for optimal model geometry included a screen angle of 56° from the horizontal plane with a total surface area of 293.9 cm2 and a priming volume of 192.4 mL. This article describes in brief the developmental process used to advance a new filter design and supports the value of numerical modeling in this undertaking. PMID:23198394

  20. Development of a new arterial-line filter design using computational fluid dynamics analysis.

    PubMed

    Herbst, Daniel P; Najm, Hani K

    2012-09-01

    Arterial-line filters used during extracorporeal circulation continue to rely on the physical properties of a wetted micropore and reductions in blood flow velocity to affect air separation from the circulating blood volume. Although problems associated with air embolism during cardiac surgery persist, a number of investigators have concluded that further improvements in filtration are needed to enhance air removal during cardiopulmonary bypass procedures. This article reviews theoretical principles of micropore filter technology and outlines the development of a new arterial-line filter concept using computational fluid dynamics analysis. Manufacturer-supplied data of a micropore screen and experimental results taken from an ex vivo test circuit were used to define the inputs needed for numerical modeling of a new filter design. Flow patterns, pressure distributions, and velocity profiles predicted with computational fluid dynamics software were used to inform decisions on model refinements and how to achieve initial design goals of < or = 225 mL prime volume and < or = 500 cm2 of screen surface area. Predictions for optimal model geometry included a screen angle of 56 degrees from the horizontal plane with a total surface area of 293.9 cm2 and a priming volume of 192.4 mL. This article describes in brief the developmental process used to advance a new filter design and supports the value of numerical modeling in this undertaking.

  1. RNAi screening of subtracted transcriptomes reveals tumor suppression by taurine-activated GABAA receptors involved in volume regulation

    PubMed Central

    van Nierop, Pim; Vormer, Tinke L.; Foijer, Floris; Verheij, Joanne; Lodder, Johannes C.; Andersen, Jesper B.; Mansvelder, Huibert D.; te Riele, Hein

    2018-01-01

    To identify coding and non-coding suppressor genes of anchorage-independent proliferation by efficient loss-of-function screening, we have developed a method for enzymatic production of low complexity shRNA libraries from subtracted transcriptomes. We produced and screened two LEGO (Low-complexity by Enrichment for Genes shut Off) shRNA libraries that were enriched for shRNA vectors targeting coding and non-coding polyadenylated transcripts that were reduced in transformed Mouse Embryonic Fibroblasts (MEFs). The LEGO shRNA libraries included ~25 shRNA vectors per transcript which limited off-target artifacts. Our method identified 79 coding and non-coding suppressor transcripts. We found that taurine-responsive GABAA receptor subunits, including GABRA5 and GABRB3, were induced during the arrest of non-transformed anchor-deprived MEFs and prevented anchorless proliferation. We show that taurine activates chloride currents through GABAA receptors on MEFs, causing seclusion of cell volume in large membrane protrusions. Volume seclusion from cells by taurine correlated with reduced proliferation and, conversely, suppression of this pathway allowed anchorage-independent proliferation. In human cholangiocarcinomas, we found that several proteins involved in taurine signaling via GABAA receptors were repressed. Low GABRA5 expression typified hyperproliferative tumors, and loss of taurine signaling correlated with reduced patient survival, suggesting this tumor suppressive mechanism operates in vivo. PMID:29787571

  2. A Microfluidic Approach for Studying Piezo Channels.

    PubMed

    Maneshi, M M; Gottlieb, P A; Hua, S Z

    2017-01-01

    Microfluidics is an interdisciplinary field intersecting many areas in engineering. Utilizing a combination of physics, chemistry, biology, and biotechnology, along with practical applications for designing devices that use low volumes of fluids to achieve high-throughput screening, is a major goal in microfluidics. Microfluidic approaches allow the study of cells growth and differentiation using a variety of conditions including control of fluid flow that generates shear stress. Recently, Piezo1 channels were shown to respond to fluid shear stress and are crucial for vascular development. This channel is ideal for studying fluid shear stress applied to cells using microfluidic devices. We have developed an approach that allows us to analyze the role of Piezo channels on any given cell and serves as a high-throughput screen for drug discovery. We show that this approach can provide detailed information about the inhibitors of Piezo channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. American Cancer Society Lung Cancer Screening Guidelines

    PubMed Central

    Wender, Richard; Fontham, Elizabeth T. H.; Barrera, Ermilo; Colditz, Graham A.; Church, Timothy R.; Ettinger, David S.; Etzioni, Ruth; Flowers, Christopher R.; Gazelle, G. Scott; Kelsey, Douglas K.; LaMonte, Samuel J.; Michaelson, James S.; Oeffinger, Kevin C.; Shih, Ya-Chen Tina; Sullivan, Daniel C.; Travis, William; Walter, Louise; Wolf, Andrew M. D.; Brawley, Otis W.; Smith, Robert A.

    2013-01-01

    Findings from the National Cancer Institute’s National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation. PMID:23315954

  4. New portable FELIX 3D display

    NASA Astrophysics Data System (ADS)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  5. [Health technology assessment report: Computer-assisted Pap test for cervical cancer screening].

    PubMed

    Della Palma, Paolo; Moresco, Luca; Giorgi Rossi, Paolo

    2012-01-01

    HEALTH PROBLEM: Cervical cancer is a disease which is highly preventable by means of Pap test screening for the precancerous lesions, which can be easily treated. Furthermore, in the near future, control of the disease will be enhanced by the vaccination which prevents the infection of those human papillomavirus types that cause the vast majority of cervical cancers. The effectiveness of screening in drastically reducing cervical cancer incidence has been clearly demonstrated. The epidemiology of cervical cancer in industrialised countries is now determined mostly by the Pap test coverage of the female population and by the ability of health systems to assure appropriate follow up after an abnormal Pap test. Today there are two fully automated systems for computer-assisted Pap test: the BD FocalPoint and the Hologic Imager. Recently, the Hologic Integrated Imager, a semi-automated system, was launched. The two fully automated systems are composed of a central scanner, where the machine examines the cytologic slide, and of one or more review stations, where the cytologists analyze the slides previously centrally scanned. The softwares used by the two systems identify the fields of interest so that the cytologists can look only at those points, automatically pointed out by the review station. Furthermore, the FocalPoint system classifies the slides according to their level of risk of containing signs of relevant lesions. Those in the upper classes--about one fifth of the slides--are labelled as « further review », while those in the lower level of risk, i.e. slides that have such a low level of risk that they can be considered as negative with no human review, are labelled as « no further review ». The aim of computer-assisted Pap test is to reduce the time of slide examination and to increase productivity. Furthermore, the number of errors due to lack of attention may decrease. Both the systems can be applied to liquidbased cytology, while only the BD Focal Point can be used on conventional smears. Cytology screening has some critical points: there is a shortage of cytologists/cytotechnicians; the quality strongly depends on the experience and ability of the cytologist; there is a subjective component in the cytological diagnosis; in highly screened populations, the prevalence of lesions is very low and the activity of cytologists is very monotonous. On the other hand, a progressive shift to molecular screening using HPV-DNA test as primary screening test is very likely in the near future; cytology will be used as triage test, dramatically reducing the number of slides to process and increasing the prevalence of lesions in those Pap tests. In this Report we assume that the diagnostic accuracy of computer-assisted Pap test is equal to the accuracy of manual Pap test and, consequently, that screening using computer-assisted Pap test has the same efficacy in reducing cervical cancer incidence and mortality. Under this assumption, the effectiveness/ benefit/utility is the same for the two screening modes, i.e. the economic analysis will be a cost minimization study. Furthermore, the screening process is identical for the two modalities in all the phases except for slide interpretation. The cost minimization analysis will be limited to the only phase differing between the two modes, i.e. the study will be a differential cost analysis between a labour-intensive strategy (traditional Pap test) and a technology-intensive strategy (the computer-assisted Pap test). Briefly, the objectives of this HTA Report are: to determine the break even point of computer-assisted Pap test systems, i.e. the volume of slides processed per year at which putting in place a computer-assisted Pap test system becomes economically convenient; to quantify the cost per Pap test in different scenarios according to screening centre activity volume, productivity of cytologist, type of cytology (conventional smear or liquid-based, fully automated or semi-automated computer-assisted); to analyse the computer-assisted Pap test in the Italian context, through a survey of the centres using the technology, collecting data useful for the sensitivity analysis of the economic evaluation; to evaluate the acceptability of the technology in the screening services; to evaluate the organizational and financial impact of the computer-assisted Pap test in different scenarios; to illustrate the ideal organization to implement computer-assisted Pap test in terms of volume of activity, productivity, and human and technological resources. to produce this Report, the following process was adopted: application to the Ministry of health for a grant « Analysis of the impact of professional involvement in evidence generation for the HTA process »; within this project, the sub-project « Cost effectiveness evaluation of the computer-assisted Pap test in the Italian screening programmes » was financed; constitution of the Working Group, which included the project coordinator, the principal investigator, and the health economist; identification of the centres using the computer-assisted Pap test and which had published scientific reports on the subject; identification of the Consulting Committee (stakeholder), which included screening programmes managers, pathologists, economists, health policy-makers, citizen organizations, and manufacturers. Once the evaluation was concluded, a plenary meeting with Working Group and Consulting Committee was held. The working group drafted the final version of this Report, which took into account the comments received. the fully automated computer-assisted Pap test has an important financial and organizational impact on screening programmes. The assessment of this health technology reached the following conclusions: according to the survey results, after some distrust, cytologists accepted the use of the machine and appreciated the reduction in interpretation time and the reliability in identifying the fields of interest; from an economic point of view, the automated computer-assisted Pap test can be convenient only with conventional smears if the screening centre has a volume of more than 49,000 slides/year and the cytologist productivity increases about threefold. It must be highlighted that it is not sufficient to adopt the automated Pap test to reach such an increase in productivity; the laboratory must be organised or re-organised to optimise the use of the review stations and the person time. In the case of liquid-based cytology, the adoption of automated computer- assisted Pap test can only increase the costs. In fact, liquid-based cytology increases the cost of consumable materials but reduces the interpretation time, even in manual screening. Consequently, the reduction of human costs is smaller in the case of computer-assisted screening. Liquid-based cytology has other implications and advantages not linked to the use of computer-assisted Pap test that should be taken into account and are beyond the scope of this Report; given that the computer-assisted Pap test reduces human costs, it may be more advantageous where the cost of cytologists is higher; given the relatively small volume of activity of screening centres in Italy, computer-assisted Pap test may be reasonable for a network using only one central scanner and several remote review stations; the use of automated computer-assisted Pap test only for quality control in a single centre is not economically sustainable. In this case as well, several centres, for example at the regional level, may form a consortium to reach a reasonable number of slides to achieve the break even point. Regarding the use of a machine rather than human intelligence to interpret the slides, some ethical issues were initially raised, but both the scientific community and healthcare professionals have accepted this technology. The identification of fields of interest by the machine is highly reproducible, reducing subjectivity in the diagnostic process. The Hologic system always includes a check by the human eye, while the FocalPoint system identifies about one fifth of the slides as No Further Review. Several studies, some of which conducted in Italy, confirmed the reliability of this classification. There is still some resistance to accept the practice of No Further Review. A check of previous slides and clinical data can be useful to make the cytologist and the clinician more confident. Computer-assisted automated Pap test may be introduced only if there is a need to increase the volume of slides screened to cover the screening target population and sufficient human resources are not available. Switching a programme using conventional slides to automatic scanning can only lead to a reduction in costs if the volume of slides per year exceeds 49,000 slides/annum and cytologist productivity is optimised to more than 20,000 slides per year. At a productivity of 15,000 or fewer, the automated computer-assisted Pap test cannot be convenient. Switching from manual screening with conventional slides to automatic scanning with liquid-based cytology cannot generate any economic saving, but the system could increase output with a given number of staff. The transition from manual to computer assisted automated screening of liquid based cytology will not generate savings and the increase in productivity will be lower than that of the switch from manual/conventional to automated/conventional. The use of biologists or pathologists as cytologists is more costly than the use of cytoscreeners. Given that the automated computer-assisted Pap test reduces human resource costs, its adoption in a model using only biologists and pathologists for screening is more economically advantageous. (ABSTRACT TRUNCATED)

  6. Balancing volume and duration of information consumption by physicians: The case of health information exchange in critical care.

    PubMed

    Politi, Liran; Codish, Shlomi; Sagy, Iftach; Fink, Lior

    2017-07-01

    The realization of the potential benefits of health information exchange systems (HIEs) for emergency departments (EDs) depends on the way these systems are actually used. The attributes of volume of information and duration of information processing are important for the study of HIE use patterns in the ED, as cognitive load and time constraints may result in a trade-off between these attributes. Experts and non-experts often use different problem-solving strategies, which may be consequential for their system use patterns. Little previous research focuses on the trade-off between volume and duration of system use or on the factors that affect it, including user expertise. This study aims at exploring the trade-off of volume and duration of use, examining whether this relationship differs between experts and non-experts, and identifying factors that are associated with use patterns characterized by volume and duration. The research objectives are pursued in the context of critically-ill patients, treated at a busy ED in the period 2010-2012. The primary source of internal and external data is an HIE linked to 14 hospitals, over 1300 clinics, and other clinical facilities. We define four use profiles based on the attributes of duration and volume: quick and basic, quick and deep, slow and basic, and slow and deep. The volume and duration of use are computed using HIE log files as the number of screens and the time per screen, respectively. Each session is then classified into a specific profile based on distances from predefined profile centroids. Experts are physicians that are board-certified in emergency medicine. We test the distribution of use profiles and their associations with multiple variables that describe the patient, physician, situation, information available in the HIE system, and use dynamics within the encounter. The quick and basic profile is the most prevalent. While available admission summaries are associated with quick and basic use, lab and imaging results are associated with slower or deeper use. Physicians who are the first to use the system or are sole users during an encounter are less inclined to quick and deep use. These effects are intensified for experts. A trade-off between volume and duration is identified. While system use is overall similar for experts and non-experts, the circumstances in which a certain profile is more likely to be observed vary across these two groups. Information availability and multiple-physician dynamics within the encounter emerge as important for the prediction of use profiles. The findings of this study provide implications for the design, implementation, and research of HIE use. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Voyager electronic parts radiation program. Volume 2: Test requirements and procedures

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Martin, K. E.; Price, W. E.

    1978-01-01

    Documents are presented outlining the conditions and requirements of the test program. The Appendixes are as follows: appendix A -- Electron Simulation Radiation Test Specification for Voyager Electronic Parts and Devices, appendix B -- Electronic Piece-Part Testing Program for Voyager, appendix C -- Test Procedure for Radiation Screening of Voyager Piece Parts, appendix D -- Boeing In Situ Test Fixture, and appendix E -- Irradiate - Anneal (IRAN) Screening Documents.

  8. Army Library Institute V: Product/Marketing/Service - Volume 2, Supplementary Data

    DTIC Science & Technology

    1981-11-01

    Rinctlons OCLC for Beginners Performance Standards Screening Panel Session 4, Thursday, 21 May 1981 Task Force Group Meetings ADP/Networking...for Library Functions W OCLC for Beginners X Career Programs and Position Classification Standards Y Screening Panel...is non-DLC a librarian will examine it, assign a call number, and do any other editing. For a flowchart , see Appendix 6, but remember that this is a

  9. Selecting the Best and Brightest: A Structured Approach to Orthopedic Resident Selection.

    PubMed

    Schenker, Mara L; Baldwin, Keith D; Israelite, Craig L; Levin, L Scott; Mehta, Samir; Ahn, Jaimo

    2016-01-01

    Resident selection is integral to the graduate medical educational process and the future of our profession. There is no consensus among residency directors as to how to systematically and consistently screen and select applicants who would perform well as residents. The purpose of this study was to introduce and assess a high volume application screening tool and semistructured interview process. This study took place in an academic orthopedic surgery department over 2 years (2013-2014). Overall, 1382 applications were screened in 7 categories, with a maximum score of 100. A total of 14 faculty reviewed applications; 218 interviews were offered; 165 applicants accepted the interview. Overall, 4 interview domains (cognitive, affective, activities, and theme), and an impression score were ranked from 1 (Exceptional) to 6 (Concern). Each room had an assigned "theme" (ethics, affective, cognitive, research, and "fit") with standardized questions. A summary score was generated of all scores to determine the preliminary rank list; the final rank list was determined after group discussion. Correlation between preliminary rank, final rank, and screening scores were assessed. The average screening score was 62.5 (range: 0-100, median = 64). The average interview score was 69.5 (range: 32.24-95.0). Final rank lists correlated most highly with initial rank (0.912, p < 0.001), impression (0.847, p < 0.001), and affective domain (0.834, p < 0.001). Cognitive domain (0.628, p < 0.001) and screening scores (0.264, p < 0.001) less highly correlated with final rank position. A systematic approach was used to screen and evaluate a large number of orthopedic surgery applicants. Our system demonstrated excellent feasibility, reliability, and predictability for the final rank list. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. Critical congenital heart disease screening practices among licensed midwives in washington state.

    PubMed

    Evers, Patrick D; Vernon, Margaret M; Schultz, Amy H

    2015-01-01

    Since 2011, pulse oximetry screening for critical congenital heart disease (CCHD) has been recommended for newborns. Initial implementation guidelines focused on in-hospital births. Recent publications affirm the importance of universal screening, including for out-of-hospital births. No published data describe CCHD screening rates for out-of-hospital births. Licensed midwives in Washington state were surveyed regarding their current CCHD screening practices, volume of births attended annually, and typical newborn follow-up practices. For those who indicated they were screening, additional information was obtained about equipment used, timing of screening, and rationale for voluntarily initiating screening. For those who indicated that they were not screening, information regarding barriers to implementation was solicited. Of the 61 midwives in our sample, 98% indicated they were aware of published guidelines recommending universal newborn screening for CCHD utilizing pulse oximetry. Furthermore, 52% indicated that they were screening for CCHD currently. Ten percent stated they do not intend to screen, whereas the remaining respondents indicated that they plan to screen in the future. The primary barriers to screening were the cost of pulse oximetry equipment and inadequate training in screening technique and interpretation. Although voluntary implementation of CCHD screening by licensed midwives in Washington is increasing, it lags behind the implementation rates reported for in-hospital births. © 2015 by the American College of Nurse-Midwives.

  11. Effects of obstructive sleep apnea on hemodynamic parameters in patients entering cardiac rehabilitation.

    PubMed

    Hargens, Trent A; Aron, Adrian; Newsome, Laura J; Austin, Joseph L; Shafer, Brooke M

    2015-01-01

    Obstructive sleep apnea (OSA) is a prevalent form of sleep-disordered breathing. Evidence suggests that OSA may lead to cardiac remodeling, although the literature is equivocal. Previous literature suggests a high percentage of individuals entering a cardiac rehabilitation (CR) program also have OSA. The objective of this study was to determine whether resting hemodynamic variables were altered in OSA subjects entering CR compared with those without OSA, as determined by impedance cardiography. Subjects entering an early outpatient CR program were screened for OSA using an at-home screening device and verified by a sleep physician. Subjects were divided into an OSA group (n = 48) or a control group (n = 25) on the basis of the screening results. Hemodynamic variables were measured during supine rest using impedance cardiography. A 6-minute walk test was performed to assess functional capacity. The proportion of cardiac diagnoses was similar between groups. Overall, 66% of the subjects were positive for OSA. Subject groups did not differ by age, body mass index, heart rate, diastolic blood pressure, or functional capacity. Cardiac output, cardiac index, stroke volume, contractility index, and left cardiac work index were all significantly decreased in the OSA group compared with the control group (P < .05). Findings suggest that OSA results in decreased cardiac function in patients entering CR, likely because of pressure and volume changes associated with apneic events. This may place those individuals at a disadvantage in recovering from their cardiac event, and place them at increased risk for secondary complications.

  12. Absorbance and fluorometric sensing with capillary wells microplates.

    PubMed

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian; Liew, Oi Wah; Ng, Tuck Wah

    2010-12-01

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.

  13. Using pre-screening methods for an effective and reliable site characterization at megasites.

    PubMed

    Algreen, Mette; Kalisz, Mariusz; Stalder, Marcel; Martac, Eugeniu; Krupanek, Janusz; Trapp, Stefan; Bartke, Stephan

    2015-10-01

    This paper illustrates the usefulness of pre-screening methods for an effective characterization of polluted sites. We applied a sequence of site characterization methods to a former Soviet military airbase with likely fuel and benzene, toluene, ethylbenzene, and xylene (BTEX) contamination in shallow groundwater and subsoil. The methods were (i) phytoscreening with tree cores; (ii) soil gas measurements for CH4, O2, and photoionization detector (PID); (iii) direct-push with membrane interface probe (MIP) and laser-induced fluorescence (LIF) sensors; (iv) direct-push sampling; and (v) sampling from soil and from groundwater monitoring wells. Phytoscreening and soil gas measurements are rapid and inexpensive pre-screening methods. Both indicated subsurface pollution and hot spots successfully. The direct-push sensors yielded 3D information about the extension and the volume of the subsurface plume. This study also expanded the applicability of tree coring to BTEX compounds and tested the use of high-resolution direct-push sensors for light hydrocarbons. Comparison of screening results to results from conventional soil and groundwater sampling yielded in most cases high rank correlation and confirmed the findings. The large-scale application of non- or low-invasive pre-screening can be of help in directing and focusing the subsequent, more expensive investigation methods. The rapid pre-screening methods also yielded useful information about potential remediation methods. Overall, we see several benefits of a stepwise screening and site characterization scheme, which we propose in conclusion.

  14. Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography.

    PubMed

    Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay

    2018-01-01

    Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.

  15. Birth weight and neonatal adiposity prediction using fractional limb volume obtained with 3D ultrasound.

    PubMed

    O'Connor, Clare; O'Higgins, Amy; Doolan, Anne; Segurado, Ricardo; Stuart, Bernard; Turner, Michael J; Kennelly, Máireád M

    2014-01-01

    The objective of this investigation was to study fetal thigh volume throughout gestation and explore its correlation with birth weight and neonatal body composition. This novel technique may improve birth weight prediction and lead to improved detection rates for fetal growth restriction. Fractional thigh volume (TVol) using 3D ultrasound, fetal biometry and soft tissue thickness were studied longitudinally in 42 mother-infant pairs. The percentages of neonatal body fat, fat mass and fat-free mass were determined using air displacement plethysmography. Correlation and linear regression analyses were performed. Linear regression analysis showed an association between TVol and birth weight. TVol at 33 weeks was also associated with neonatal fat-free mass. There was no correlation between TVol and neonatal fat mass. Abdominal circumference, estimated fetal weight (EFW) and EFW centile showed consistent correlations with birth weight. Thigh volume demonstrated an additional independent contribution to birth weight prediction when added to the EFW centile from the 38-week scan (p = 0.03). Fractional TVol performed at 33 weeks gestation is correlated with birth weight and neonatal lean body mass. This screening test may highlight those at risk of fetal growth restriction or macrosomia.

  16. Segmentation of real-time three-dimensional ultrasound for quantification of ventricular function: a clinical study on right and left ventricles.

    PubMed

    Angelini, Elsa D; Homma, Shunichi; Pearson, Gregory; Holmes, Jeffrey W; Laine, Andrew F

    2005-09-01

    Among screening modalities, echocardiography is the fastest, least expensive and least invasive method for imaging the heart. A new generation of three-dimensional (3-D) ultrasound (US) technology has been developed with real-time 3-D (RT3-D) matrix phased-array transducers. These transducers allow interactive 3-D visualization of cardiac anatomy and fast ventricular volume estimation without tomographic interpolation as required with earlier 3-D US acquisition systems. However, real-time acquisition speed is performed at the cost of decreasing spatial resolution, leading to echocardiographic data with poor definition of anatomical structures and high levels of speckle noise. The poor quality of the US signal has limited the acceptance of RT3-D US technology in clinical practice, despite the wealth of information acquired by this system, far greater than with any other existing echocardiography screening modality. We present, in this work, a clinical study for segmentation of right and left ventricular volumes using RT3-D US. A preprocessing of the volumetric data sets was performed using spatiotemporal brushlet denoising, as presented in previous articles Two deformable-model segmentation methods were implemented in 2-D using a parametric formulation and in 3-D using an implicit formulation with a level set implementation for extraction of endocardial surfaces on denoised RT3-D US data. A complete and rigorous validation of the segmentation methods was carried out for quantification of left and right ventricular volumes and ejection fraction, including comparison of measurements with cardiac magnetic resonance imaging as the reference. Results for volume and ejection fraction measurements report good performance of quantification of cardiac function on RT3-D data compared with magnetic resonance imaging with better performance of semiautomatic segmentation methods than with manual tracing on the US data.

  17. Chlamydia screening in England: a qualitative study of the narrative behind the policy

    PubMed Central

    2012-01-01

    Background The rationale for the English National Chlamydia Screening Programme (NCSP) has been questioned. There has been little analysis, however, of what drove the NCSP’s establishment and how it was implemented. Such analysis will help inform the future development of the NCSP. This study used a qualitative, theory-driven approach to evaluate the rationale for the NCSP’s establishment and implementation. Methods Semi-structured interviews with 14 experts in chlamydia screening were undertaken. The interview data were analysed with policy documents and commentaries from peer-reviewed journals (published 1996–2010) using the Framework approach. Results Two themes drove the NCSP’s establishment and implementation. The first, chlamydia control, was prominently referenced in documents and interviews. The second theme concerned the potential for chlamydia screening to advance wider improvements in sexual health. In particular, screening was expected to promote sexual health services in primary care and encourage discussion of sexual health with young people. While this theme was only indirectly referenced in policy documents, it was cited by interviewees as a strong influence on implementation in the early years. However, by full rollout of the Programme, a focus on screening volume may have limited the NCSP’s capacity to improve broader aspects of sexual health. Conclusions A combination of explicit and implicit drivers underpinned the Programme’s establishment. This combination may explain why there was widespread support for its introduction and why implementation of the NCSP was inconsistent. The potential to improve young people’s sexual health more comprehensively should be made explicit in future planning of the NCSP. PMID:22545922

  18. Efficient Sporulation of Saccharomyces cerevisiae in a 96 Multiwell Format.

    PubMed

    Paulissen, Scott M; Huang, Linda S

    2016-09-17

    During times of nutritional stress, Saccharomyces cerevisiae undergoes gametogenesis, known as sporulation. Diploid yeast cells that are starved for nitrogen and carbon will initiate the sporulation process. The process of sporulation includes meiosis followed by spore formation, where the haploid nuclei are packaged into environmentally resistant spores. We have developed methods for the efficient sporulation of budding yeast in 96 multiwell plates, to increase the throughput of screening yeast cells for sporulation phenotypes. These methods are compatible with screening with yeast containing plasmids requiring nutritional selection, when appropriate minimal media is used, or with screening yeast with genomic alterations, when a rich presporulation regimen is used. We find that for this method, aeration during sporulation is critical for spore formation, and have devised techniques to ensure sufficient aeration that are compatible with the 96 multiwell plate format. Although these methods do not achieve the typical ~80% level of sporulation that can be achieved in large-volume flask based experiments, these methods will reliably achieve about 50-60% level of sporulation in small-volume multiwell plates.

  19. CT Lung Cancer Screening Program Development: Part 2.

    PubMed

    Yates, Teri

    2015-01-01

    Radiology administrators must use innovative strategies around clinical collaboration and marketing to ensure that patients access the service in sufficient numbers. Radiology Associates of South Florida in collaboration with Baptist Health South Florida have developed a successful lung cancer screening program. The biggest factors in their success have been the affordability of their service and the quality of the program. Like mammography, lung cancer screening programs serve as an entry point to other services that generate revenue for the hospital. Patients may require further evaluation in the form of more imaging or surgical services for biopsy. Part 1 provided background and laid out fundamentals for starting a program. Part 2 focuses on building patient volume, marketing, and issues related to patient management after the screen is performed.

  20. Feasibility of telemammography as biomedical application for breast imaging

    NASA Astrophysics Data System (ADS)

    Beckerman, Barbara G.; Batsell, Stephen G.; MacIntyre, Lawrence P.; Sarraf, Hamed S.; Gleason, Shaun S.; Schnall, Mitchell D.

    1999-07-01

    Mammographic screening is an important tool in the early detection of breast cancer. The migration of mammography from the current mode of x-ray mammography using a film screen image detector and display to a digital technology provides an opportunity to improve access and performance of breast cancer screening. The sheer size and volume of the typical screening exam, the need to have previous screening data readily available, and the need to view other breast imaging data together to provide a common consensus and to plan treatment, make telemammography an ideal application for breast imaging. For telemammography to be a viable option, it must overcome the technical challenges related to transmission, archiving, management, processing and retrieval of large data sets. Researchers from the University of Pennsylvania, the University of Chicago and Lockheed Martin Energy Systems/Oak Ridge National Laboratory have developed a framework for transmission of large-scale medical images over high-speed networks, leveraged existing high-speed networks between research and medical facilities; tested the feasibility of point-to-point transmission of mammographic images in a near-real time environment; evaluated network performance and transmission scenarios; and investigated the impact of image preprocessing on an experimental computer-aided diagnosis system. Results of the initial study are reported here.

  1. Gas separation and bubble behavior at a woven screen

    NASA Astrophysics Data System (ADS)

    Conrath, Michael; Dreyer, Michael E.

    Gas-liquid two phase flows are widespread and in many applications the separation of both phases is necessary. Chemical reactors, water treatment devices or gas-free delivery of liquids like propellant are only some of them. We study the performance of a woven metal screen in respect to its phase separation behavior under static and dynamic conditions. Beside hydraulic screen resistance and static bubble point, our study also comprises the bubble detachment from the screen upon gas breakthrough. Since a woven screen is essentially an array of identical pores, analogies to bubble detachment from a needle can be established. While the bubble point poses an upper limit for pressurized gas at a wetted screen to preclude gas breakthrough, the necessary pressure for growing bubbles to detach from the screen pores a lower limit when breakthrough is already in progress. Based on that inside, the dynamic bubble point effects were constituted that relate to a trapped bubble at such a screen in liquid flow. A trapped is caused to break through the screen by the flow-induced pressure drop across it. Our model includes axially symmetric bubble shapes, degree of coverage of the screen and bubble pressurization due to hydraulic losses in the rest of the circuit. We have built an experiment that consists of a Dutch Twilled woven screen made of stainless steel in a vertical acrylic glass tube. The liquid is silicon oil SF0.65. The screen is suspended perpendicular to the liquid flow which is forced through it at variable flow rate. Controlled injection of air from a needle allows us to examine the ability of the screen to separate gas and liquid along the former mentioned effects. We present experimental data on static bubble point and detachment pressure for breakthrough at different gas supply rates that suggest a useful criterion for reliable static bubble point measurements. Results for the dynamic bubble point are presented that include i) screen pressure drop for different trapped bubble volumes, liquid flow rates and flow-induced compression, ii) typical breakthrough of a trapped bubble at rising liquid flow rate and iii) steady gas supply in steady liquid flow. It shows that our model can explain the experimental observations. One of the interesting findings for the dynamic bubble point is that hydraulic losses in the rest of the circuit will shift the breakthrough of gas to higher liquid flow rates.

  2. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  3. System for Initial Assessment, Management, and Physiologic Monitoring of Battlefield Casualties

    DTIC Science & Technology

    1986-03-01

    largest volume of closed head injury patients of any single hospital in the United States, the ABER study has become a screening procedure of choice...ABBREVIATED INJURY SCALE Severity Category/Injury Description Severity code GENERAL 1. -- Aches all over -- Minor lacerations, contusions, and...surface 2* or 3* burns 5. -- Over 50% body surface 20 or 30 burns HEAD AND NECK 1. -- Cerebral injury with headache; dizziness; no loss of consciousness

  4. Novel method for high-throughput colony PCR screening in nanoliter-reactors

    PubMed Central

    Walser, Marcel; Pellaux, Rene; Meyer, Andreas; Bechtold, Matthias; Vanderschuren, Herve; Reinhardt, Richard; Magyar, Joseph; Panke, Sven; Held, Martin

    2009-01-01

    We introduce a technology for the rapid identification and sequencing of conserved DNA elements employing a novel suspension array based on nanoliter (nl)-reactors made from alginate. The reactors have a volume of 35 nl and serve as reaction compartments during monoseptic growth of microbial library clones, colony lysis, thermocycling and screening for sequence motifs via semi-quantitative fluorescence analyses. nl-Reactors were kept in suspension during all high-throughput steps which allowed performing the protocol in a highly space-effective fashion and at negligible expenses of consumables and reagents. As a first application, 11 high-quality microsatellites for polymorphism studies in cassava were isolated and sequenced out of a library of 20 000 clones in 2 days. The technology is widely scalable and we envision that throughputs for nl-reactor based screenings can be increased up to 100 000 and more samples per day thereby efficiently complementing protocols based on established deep-sequencing technologies. PMID:19282448

  5. Oak Ridge Health Studies Phase 1 report, Volume 2, Part B, Dose Reconstruction Feasibility Study. Tasks 3 and 4, Identification of important environmental pathways for materials released from the Oak Ridge Reservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brorby, G.P.; Bruce, G.M.; Widner, T.E.

    1993-09-01

    While each of the three different screening comparisons made in this report (i.e., within-medium evaluation, between-media evaluation and relative importance grouping) individually provides information potentially of value in focusing future studies, each one is subject to a variety of limitations, the most important being associated with the absence or variable quality of environmental data for a number of the contaminants and media. These screening exercises are intended to provide an initial framework for approaching the study of an extremely complex site. Other approaches could very well yield somewhat different priorities, and the identification or reinterpretation of data in subsequent detailedmore » studies are likely to invalidate some of the results of these screening exercises. However, these evaluations provide a logical approach to defining initial off- site health impact study priorities for the ORR. Therefore, while care must be taken in attempting to make any broad generalizations or greatly simplifying assumptions with regard to the potential health hazards posed by the complex releases from the Reservation, Table 6-1 represents an attempt to summarize a set of recommendations that are derived from the screening exercises presented in this report. Table 6-1 identifies the facilities, processes and contaminants believed to have the highest potential for resulting in off-site health impacts. Table 6-2 identifies contaminants for which no ranking could be performed as part of this feasibility study, because of the absence of any appropriate data for any environmental medium.« less

  6. American Cancer Society lung cancer screening guidelines.

    PubMed

    Wender, Richard; Fontham, Elizabeth T H; Barrera, Ermilo; Colditz, Graham A; Church, Timothy R; Ettinger, David S; Etzioni, Ruth; Flowers, Christopher R; Gazelle, G Scott; Kelsey, Douglas K; LaMonte, Samuel J; Michaelson, James S; Oeffinger, Kevin C; Shih, Ya-Chen Tina; Sullivan, Daniel C; Travis, William; Walter, Louise; Wolf, Andrew M D; Brawley, Otis W; Smith, Robert A

    2013-01-01

    Findings from the National Cancer Institute's National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation. Copyright © 2013 American Cancer Society, Inc.

  7. SCREEN: A simple layperson administered screening algorithm in low resource international settings significantly reduces waiting time for critically ill children in primary healthcare clinics.

    PubMed

    Hansoti, Bhakti; Jenson, Alexander; Kironji, Antony G; Katz, Joanne; Levin, Scott; Rothman, Richard; Kelen, Gabor D; Wallis, Lee A

    2017-01-01

    In low resource settings, an inadequate number of trained healthcare workers and high volumes of children presenting to Primary Healthcare Centers (PHC) result in prolonged waiting times and significant delays in identifying and evaluating critically ill children. The Sick Children Require Emergency Evaluation Now (SCREEN) program, a simple six-question screening algorithm administered by lay healthcare workers, was developed in 2014 to rapidly identify critically ill children and to expedite their care at the point of entry into a clinic. We sought to determine the impact of SCREEN on waiting times for critically ill children post real world implementation in Cape Town, South Africa. This is a prospective, observational implementation-effectiveness hybrid study that sought to determine: (1) the impact of SCREEN implementation on waiting times as a primary outcome measure, and (2) the effectiveness of the SCREEN tool in accurately identifying critically ill children when utilised by the QM and adherence by the QM to the SCREEN algorithm as secondary outcome measures. The study was conducted in two phases, Phase I control (pre-SCREEN implementation- three months in 2014) and Phase II (post-SCREEN implementation-two distinct three month periods in 2016). In Phase I, 1600 (92.38%) of 1732 children presenting to 4 clinics, had sufficient data for analysis and comprised the control sample. In Phase II, all 3383 of the children presenting to the 26 clinics during the sampling time frame had sufficient data for analysis. The proportion of critically ill children who saw a professional nurse within 10 minutes increased tenfold from 6.4% to 64% (Phase I to Phase II) with the median time to seeing a professional nurse reduced from 100.3 minutes to 4.9 minutes, (p < .001, respectively). Overall layperson screening compared to Integrated Management of Childhood Illnesses (IMCI) designation by a nurse had a sensitivity of 94.2% and a specificity of 88.1%, despite large variance in adherence to the SCREEN algorithm across clinics. The SCREEN program when implemented in a real-world setting can significantly reduce waiting times for critically ill children in PHCs, however further work is required to improve the implementation of this innovative program.

  8. Screening of formulation variables for the preparation of poly(epsilon-caprolactone) nanocapsules containing the local anesthetic benzocaine.

    PubMed

    Moraes, Carolina Morales; de Matos, Angélica Prado; Grillo, Renato; de Melo, Nathalie F S; de Paula, Eneida; Dias Filho, Newton Luiz; Rosa, André Henrique; Fraceto, Leonardo Fernandes

    2011-03-01

    In this work we describe the screening of four parameters in the preparation, by nanoprecipitation, of poly(epsilon-caprolactone) nanocapsules, used as a drug carrier system for the local anesthetic, benzocaine. A 2(4-1) factorial experimental design was used to study the influence of four different independent variables (polymer, oily phase, Span 60 and Tween 80) on nanocapsule characteristics (size, polydispersion index, zeta potential) and drug loading capability. Best results were obtained using an aqueous formulation comprising 100 mg of polymer, 200 mg of oily phase, 40 mg of Span 60 and 60 mg of Tween 80 in a final volume of 10 mL which produced a colloidal system with particle size of 188 nm, zeta potential -32 mV, polydispersion index 0.07, and benzocaine association efficiency > 87%. These findings open the way for future clinical studies using such formulations.

  9. Study terrestrial applications of solar cell powered systems

    NASA Technical Reports Server (NTRS)

    Ravin, J. W.

    1973-01-01

    Terrestrial applications of solar cells and design systems are considered for those applications that show the most promise for becoming practical and accepted by users within the next five years. The study includes the definition, categorization, evaluation and screening of the most attractive potential terrestrial applications for solar cells. Potential markets are initially grouped and categorized in a general sense and are weighted in priority by their business volume, present and future. From a categorized list including marine, transportation, security, communication, meteorological and others, 66 potential solar cell applications have been cataloged. A methodology was formulated to include the criteria for evaluation and screening. The evaluation process covers all parts and components of the complete system required for each application and gives consideration to all factors, such as engineering, economic, production, marketing and other factors that may have an influence on the acceptance of the system.

  10. Absorbance and fluorometric sensing with capillary wells microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian

    2010-12-15

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly inmore » the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.« less

  11. Newborn screening blood spot analysis in the UK: influence of spot size, punch location and haematocrit.

    PubMed

    Lawson, A J; Bernstone, L; Hall, S K

    2016-03-01

    In dried blood spot analysis, punch location and variations in applied sample volume and haematocrit can produce different measured concentrations of analytes. We investigated the magnitude of these effects in newborn screening in the UK. Heparinized blood spiked with thyroid stimulating hormone (TSH), phenylalanine, tyrosine, leucine, methionine, octanoyl carnitine (C8), and immunoreactive trypsinogen (IRT) was spotted onto filter paper: (i) at a constant haematocrit of 50% at various volumes, and (ii) at a range of haematocrits using a constant volume. Subpunches (3.2 mm) of the dried blood spots were then analysed. Compared with a central punch from a 50 µL blood spot with 50% haematocrit, 10 µL spots can have significantly lower measured concentrations of all analytes, with decreases of 15% or more observed for leucine, methionine, phenylalanine, and tyrosine. Punching at the edge of a spot can increase measured concentrations up to 35%. Higher haematocrit decreased measured TSH and C8 yet increased amino acids and IRT by 15% compared with 50% haematocrit. Lower haematocrits had the opposite effect, but only with higher concentrations of some analytes. Differences in blood spot size, haematocrit and punch location substantially affect measured concentrations for analytes used in the UK newborn screening programme, and this could affect false positive and negative rates. To minimize analytical bias, these variables should be controlled or adjusted for where possible. © The Author(s) 2015.

  12. Pituitary gland volume and psychosocial stress among children at elevated risk for schizophrenia.

    PubMed

    Cullen, A E; Day, F L; Roberts, R E; Pariante, C M; Laurens, K R

    2015-11-01

    Pituitary volume enlargements have been observed among individuals with first-episode psychosis. These abnormalities are suggestive of hypothalamic-pituitary-adrenal (HPA) axis hyperactivity, which may contribute to the development of psychosis. However, the extent to which these abnormalities characterize individuals at elevated risk for schizophrenia prior to illness onset is currently unclear, as volume increases, decreases and no volume differences have all been reported relative to controls. The current study aimed to determine whether antipsychotic-naive, putatively at-risk children who present multiple antecedents of schizophrenia (ASz) or a family history of illness (FHx) show pituitary volume abnormalities relative to typically developing (TD) children. An additional aim was to explore the association between pituitary volume and experiences of psychosocial stress. ASz (n = 30), FHx (n = 22) and TD (n = 32) children were identified at age 9-12 years using a novel community-screening procedure or as relatives of individuals with schizophrenia. Measures of pituitary volume and psychosocial stress were obtained at age 11-14 years. Neither ASz nor FHx children showed differences in pituitary volume relative to TD children. Among FHx children only, pituitary volume was negatively associated with current distress relating to negative life events and exposure to physical punishment. The lack of pituitary volume abnormalities among ASz and FHx children is consistent with our previous work demonstrating that these children are not characterized by elevated diurnal cortisol levels. The findings imply that these biological markers of HPA axis hyperactivity, observed in some older samples of high-risk individuals, may emerge later, more proximally to disease onset.

  13. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    PubMed

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  14. In-well time-of-travel approach to evaluate optimal purge duration during low-flow sampling of monitoring wells

    USGS Publications Warehouse

    Harte, Philip T.

    2017-01-01

    A common assumption with groundwater sampling is that low (<0.5 L/min) pumping rates during well purging and sampling captures primarily lateral flow from the formation through the well-screened interval at a depth coincident with the pump intake. However, if the intake is adjacent to a low hydraulic conductivity part of the screened formation, this scenario will induce vertical groundwater flow to the pump intake from parts of the screened interval with high hydraulic conductivity. Because less formation water will initially be captured during pumping, a substantial volume of water already in the well (preexisting screen water or screen storage) will be captured during this initial time until inflow from the high hydraulic conductivity part of the screened formation can travel vertically in the well to the pump intake. Therefore, the length of the time needed for adequate purging prior to sample collection (called optimal purge duration) is controlled by the in-well, vertical travel times. A preliminary, simple analytical model was used to provide information on the relation between purge duration and capture of formation water for different gross levels of heterogeneity (contrast between low and high hydraulic conductivity layers). The model was then used to compare these time–volume relations to purge data (pumping rates and drawdown) collected at several representative monitoring wells from multiple sites. Results showed that computation of time-dependent capture of formation water (as opposed to capture of preexisting screen water), which were based on vertical travel times in the well, compares favorably with the time required to achieve field parameter stabilization. If field parameter stabilization is an indicator of arrival time of formation water, which has been postulated, then in-well, vertical flow may be an important factor at wells where low-flow sampling is the sample method of choice.

  15. Understanding the significance variables for fabrication of fish gelatin nanoparticles by Plackett-Burman design

    NASA Astrophysics Data System (ADS)

    Subara, Deni; Jaswir, Irwandi; Alkhatib, Maan Fahmi Rashid; Noorbatcha, Ibrahim Ali

    2018-01-01

    The aim of this experiment is to screen and to understand the process variables on the fabrication of fish gelatin nanoparticles by using quality-design approach. The most influencing process variables were screened by using Plackett-Burman design. Mean particles size, size distribution, and zeta potential were found in the range 240±9.76 nm, 0.3, and -9 mV, respectively. Statistical results explained that concentration of acetone, pH of solution during precipitation step and volume of cross linker had a most significant effect on particles size of fish gelatin nanoparticles. It was found that, time and chemical consuming is lower than previous research. This study revealed the potential of quality-by design in understanding the effects of process variables on the fish gelatin nanoparticles production.

  16. Dual laser optical system and method for studying fluid flow

    NASA Technical Reports Server (NTRS)

    Owen, R. B.; Witherow, W. K. (Inventor)

    1983-01-01

    A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.

  17. Reduced size of the amygdala in individuals with 47,XXY and 47,XXX karyotypes.

    PubMed

    Patwardhan, Anil J; Brown, Wendy E; Bender, Bruce G; Linden, Mary G; Eliez, Stephan; Reiss, Allan L

    2002-01-08

    The excess of 47,XXX and 47,XXY karyotypes found in cytogenetic screening studies of individuals with schizophrenia has given support for an increased risk of psychiatric illness among men and women with sex chromosomal aneuploidy (SCA). Mesial temporal lobe structures, including the amygdala and hippocampus, are thought to be associated with abnormalities of mood and behavior in humans and in the neurobiology of schizophrenia. This study focuses on variations in volumes of mesial temporal lobe structures in men and women with SCA. Utilizing an unselected birth cohort of subjects with SCA and high-resolution magnetic resonance imaging (MRI), we investigated the neuroanatomical consequences of a supernumerary X chromosome on the morphology of the amygdala and hippocampus. Regional and total brain volumes were measured in 10 subjects with 47,XXY, 10 subjects with 47,XXX, and 20 euploid controls. Amygdala volumes were significantly reduced in men with 47,XXY, compared to control men, while the decrease in women with 47,XXX was not as pronounced. Hippocampus volumes were preserved in both groups, compared to same-gender controls. Longitudinal studies of SCA individuals have shown an increased incidence of mild psychopathology and behavioral dysfunction in men with 47,XXY and more overt psychiatric illness in women with 47,XXX, compared to control populations. The alteration in amygdala volumes in individuals with a supernumerary X chromosome may provide a neuroanatomic basis for these findings. Copyright 2001 Wiley-Liss, Inc.

  18. Novel Stool-Based Protein Biomarkers for Improved Colorectal Cancer Screening: A Case-Control Study.

    PubMed

    Bosch, Linda J W; de Wit, Meike; Pham, Thang V; Coupé, Veerle M H; Hiemstra, Annemieke C; Piersma, Sander R; Oudgenoeg, Gideon; Scheffer, George L; Mongera, Sandra; Sive Droste, Jochim Terhaar; Oort, Frank A; van Turenhout, Sietze T; Larbi, Ilhame Ben; Louwagie, Joost; van Criekinge, Wim; van der Hulst, Rene W M; Mulder, Chris J J; Carvalho, Beatriz; Fijneman, Remond J A; Jimenez, Connie R; Meijer, Gerrit A

    2017-12-19

    The fecal immunochemical test (FIT) for detecting hemoglobin is used widely for noninvasive colorectal cancer (CRC) screening, but its sensitivity leaves room for improvement. To identify novel protein biomarkers in stool that outperform or complement hemoglobin in detecting CRC and advanced adenomas. Case-control study. Colonoscopy-controlled referral population from several centers. 315 stool samples from one series of 12 patients with CRC and 10 persons without colorectal neoplasia (control samples) and a second series of 81 patients with CRC, 40 with advanced adenomas, and 43 with nonadvanced adenomas, as well as 129 persons without colorectal neoplasia (control samples); 72 FIT samples from a third independent series of 14 patients with CRC, 16 with advanced adenomas, and 18 with nonadvanced adenomas, as well as 24 persons without colorectal neoplasia (control samples). Stool samples were analyzed by mass spectrometry. Classification and regression tree (CART) analysis and logistic regression analyses were performed to identify protein combinations that differentiated CRC or advanced adenoma from control samples. Antibody-based assays for 4 selected proteins were done on FIT samples. In total, 834 human proteins were identified, 29 of which were statistically significantly enriched in CRC versus control stool samples in both series. Combinations of 4 proteins reached sensitivities of 80% and 45% for detecting CRC and advanced adenomas, respectively, at 95% specificity, which was higher than that of hemoglobin alone (P < 0.001 and P = 0.003, respectively). Selected proteins could be measured in small sample volumes used in FIT-based screening programs and discriminated between CRC and control samples (P < 0.001). Lack of availability of antibodies prohibited validation of the top protein combinations in FIT samples. Mass spectrometry of stool samples identified novel candidate protein biomarkers for CRC screening. Several protein combinations outperformed hemoglobin in discriminating CRC or advanced adenoma from control samples. Proof of concept that such proteins can be detected with antibody-based assays in small sample volumes indicates the potential of these biomarkers to be applied in population screening. Center for Translational Molecular Medicine, International Translational Cancer Research Dream Team, Stand Up to Cancer (American Association for Cancer Research and the Dutch Cancer Society), Dutch Digestive Foundation, and VU University Medical Center.

  19. Federal Logistics Information System (FLIS) Procedures Manual, Volume 4. Item Identification.

    DTIC Science & Technology

    1995-01-01

    Functional I DRMS Defense Reutilization 1,15 Description and Marketing FDM Full Descriptive 2 Service Method (Item DPSC Defense Personnel 2,13,14...under DIC KRE, return code ment or segment mix of FLIS data. For interna- AU. tional cataloging, only one Output Data RequestV Code may be used per...Screening Results) with KMR (Matching NATO Maintenance and Supply Agency (NAMSA), Reference-Screening) and either KFC (File Data the custodian for control

  20. MX Siting Investigation. Geotechnical Evaluation Conterminous United States. Volume I. Coarse Screening.

    DTIC Science & Technology

    1977-06-01

    the screening process, and the number of unit siting regions of 5000 nm 2 contained in each. The highest ranked suitable areas occur in the Basin and...SUITABLE AND POTENTIALLY SUITABLE AREA............23 3.4.1 GENERAL....................23 3.4.2 BASIN AND RANGE PROVINCE. ........... 23 13.4.3 GREAT...Approximately 70 percent of total suitable area occurs in the Basin and Range, Great Plains, and Central Lowlands physiographic provinces of the western and

  1. Parallel production and verification of protein products using a novel high-throughput screening method.

    PubMed

    Tegel, Hanna; Yderland, Louise; Boström, Tove; Eriksson, Cecilia; Ukkonen, Kaisa; Vasala, Antti; Neubauer, Peter; Ottosson, Jenny; Hober, Sophia

    2011-08-01

    Protein production and analysis in a parallel fashion is today applied in laboratories worldwide and there is a great need to improve the techniques and systems used for this purpose. In order to save time and money, a fast and reliable screening method for analysis of protein production and also verification of the protein product is desired. Here, a micro-scale protocol for the parallel production and screening of 96 proteins in plate format is described. Protein capture was achieved using immobilized metal affinity chromatography and the product was verified using matrix-assisted laser desorption ionization time-of-flight MS. In order to obtain sufficiently high cell densities and product yield in the small-volume cultivations, the EnBase® cultivation technology was applied, which enables cultivation in as small volumes as 150 μL. Here, the efficiency of the method is demonstrated by producing 96 human, recombinant proteins, both in micro-scale and using a standard full-scale protocol and comparing the results in regard to both protein identity and sample purity. The results obtained are highly comparable to those acquired through employing standard full-scale purification protocols, thus validating this method as a successful initial screening step before protein production at a larger scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Droplet microfluidic technology for single-cell high-throughput screening.

    PubMed

    Brouzes, Eric; Medkova, Martina; Savenelli, Neal; Marran, Dave; Twardowski, Mariusz; Hutchison, J Brian; Rothberg, Jonathan M; Link, Darren R; Perrimon, Norbert; Samuels, Michael L

    2009-08-25

    We present a droplet-based microfluidic technology that enables high-throughput screening of single mammalian cells. This integrated platform allows for the encapsulation of single cells and reagents in independent aqueous microdroplets (1 pL to 10 nL volumes) dispersed in an immiscible carrier oil and enables the digital manipulation of these reactors at a very high-throughput. Here, we validate a full droplet screening workflow by conducting a droplet-based cytotoxicity screen. To perform this screen, we first developed a droplet viability assay that permits the quantitative scoring of cell viability and growth within intact droplets. Next, we demonstrated the high viability of encapsulated human monocytic U937 cells over a period of 4 days. Finally, we developed an optically-coded droplet library enabling the identification of the droplets composition during the assay read-out. Using the integrated droplet technology, we screened a drug library for its cytotoxic effect against U937 cells. Taken together our droplet microfluidic platform is modular, robust, uses no moving parts, and has a wide range of potential applications including high-throughput single-cell analyses, combinatorial screening, and facilitating small sample analyses.

  3. Iron deficiency anaemia in Nigerian infants.

    PubMed

    Akinkugbe, F M; Ette, S I; Durowoju, T A

    1999-01-01

    Hematological parameters and the iron status of 50 randomly selected infants who were attending the research infant welfare clinic of the Institute of Child Health, Ibadan (ICHI), for routine immunization were studied. Investigations included estimations of packed cell volume (PCV), haemoglobin (Hb), serum iron (Fe), unsaturated iron-binding capacity (UIBC) and total iron-binding Capacity (TIBC). Forty percent of the infants had PCVs below 0.32, 48% had Hbs below 10 g/dl and 27% had mean corpuscular volume (MVC) less that 70fl. Thirty-seven percent of the children had serum Fe below 3.58 mmol/l, but only 4% had UIBC above 320 mmol/l. Fifty-two percent had Transferin Saturation Index (TSI) below 10%. Eighteen percent had MCV below 70fl associated with TSI below 10% and 67% of these had Hbs below 10 g/dl. The prevalence of iron deficiency anaemia in infants as shown in this study is very high. The ill effects of iron deficiency in childhood have been well documented. It is suggested that screening for anaemia should be offered at 9 months as part of a Child Survival Programme and that infants found to be anaemic should be treated. However, for cost-effectiveness and taking into consideration the high prevalence rate of iron deficiency in this age group, it might be preferable to give iron and weekly prophylactic antimalarias routinely to infants aged 9 to 15 months in lieu of screening.

  4. Fast IRMS screening of pseudoendogenous steroids in doping analyses.

    PubMed

    de la Torre, Xavier; Colamonici, Cristiana; Curcio, Davide; Botrè, Francesco

    2017-11-01

    The detection of the abuse of pseudoendogenous steroids (testosterone and/or its precursors) is currently based, when possible, on the application of the steroid module of the World Anti-Doping Agency (WADA), athlete biological passport (ABP), implemented through the global database, ADAMS. When a suspicious sample is detected, the confirmation by isotope ratio mass spectrometry (IRMS) is required. It is well known that this confirmation procedure is time consuming and expensive and can be only applied on a reduced number of samples. In previous studies we have demonstrated that the longitudinal evaluation of the IRMS data is able to detect positive samples that otherwise will be evaluated as negative, improving the efficacy of the fight against doping in sport. This would require the analysis of a much larger volume of samples by IRMS. The aim of the present work is to describe an IRMS screening method allowing to increase the throughput of samples that can be analyzed by IRMS. The detection efficacy of the method is compared with the confirmation method in use, and to assess its robustness and applicability, all the samples of a major cycling stage competition were analyzed, with the agreement of the testing authority, under routine conditions and response times. The results obtained permit to conclude that the IRMS screening method here proposed has adequate selectivity and produces results that overlap with the already validated method currently in use permitting to analyze a much higher volume of samples even during a major event without compromising the detection capacity. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. The role of BPH, lower urinary tract symptoms, and PSA levels on erectile function of Brazilian men who undergo prostate cancer screening.

    PubMed

    Antunes, Alberto A; Srougi, Miguel; Dall'oglio, Marcos F; Vicentini, Fabio; Paranhos, Mario; Freire, Geraldo C

    2008-07-01

    Lower urinary tract symptoms (LUTS) and erectile dysfunction (ED) are common problems in middle-aged and older men. Recently, epidemiologic studies have shown significant associations between severity of LUTS and male sexual dysfunction. We analyzed the role of prostate enlargement, LUTS, and prostate specific antigen (PSA) levels in the erectile function of Brazilian men who underwent prostate cancer (PCa) screening. We analyzed data from 1,008 consecutive patients enrolled in a PCa screening program. Benign prostatic hyperplasia (BPH) was defined as a prostate weight greater than 30 g as defined by digital rectal examination. For statistical analysis, we used the chi-squared and analysis of variance tests. The odds ratios (OR) for correlation of ED with prostate volume LUTS and PSA were estimated using logistic regression models. The American Urological Association (AUA) symptom score for LUTS and the International Index of Erectile Function. Mean patient age was 61.2 years (45-87) and median PSA value was 1.9 ng/mL. BPH was identified in 48.5% of patients. Mild, moderate, and severe LUTS were found in 52.3%, 30.9%, and 16.8% of cases, respectively. ED was classified as absent, mild, mild to moderate, moderate, and severe in 18.6%, 23.1%, 18.6%, 15.2%, and 24.5%, respectively. While only 5.4% of the patients with no ED presented severe LUTS, this finding was observed in 27.1% of patients with severe ED (P < 0.001). Univariate logistic regression analysis demonstrated that age, prostate volume, AUA symptom score, and PSA levels were significant predictors of ED. However, when controlled for patient age, only LUTS remained as an independent predictor of ED. Controlling for patient age, LUTS are independent risk factors for the development of ED among Brazilian men who undergo PCa screening. Antunes AA, Srougi M, Dall'Oglio MF, Vicentini F, Paranhos M, and Freire GC. The role of BPH, lower urinary tract symptoms, and PSA levels on erectile function of Brazilian men who undergo prostate cancer screening.

  6. Target specific proteochemometric model development for BACE1 - protein flexibility and structural water are critical in virtual screening.

    PubMed

    Manoharan, Prabu; Chennoju, Kiranmai; Ghoshal, Nanda

    2015-07-01

    BACE1 is an attractive target in Alzheimer's disease (AD) treatment. A rational drug design effort for the inhibition of BACE1 is actively pursued by researchers in both academic and pharmaceutical industries. This continued effort led to the steady accumulation of BACE1 crystal structures, co-complexed with different classes of inhibitors. This wealth of information is used in this study to develop target specific proteochemometric models and these models are exploited for predicting the prospective BACE1 inhibitors. The models developed in this study have performed excellently in predicting the computationally generated poses, separately obtained from single and ensemble docking approaches. The simple protein-ligand contact (SPLC) model outperforms other sophisticated high end models, in virtual screening performance, developed during this study. In an attempt to account for BACE1 protein active site flexibility information in predictive models, we included the change in the area of solvent accessible surface and the change in the volume of solvent accessible surface in our models. The ensemble and single receptor docking results obtained from this study indicate that the structural water mediated interactions improve the virtual screening results. Also, these waters are essential for recapitulating bioactive conformation during docking study. The proteochemometric models developed in this study can be used for the prediction of BACE1 inhibitors, during the early stage of AD drug discovery.

  7. Effect of preoperative mastoid ventilation on tympanoplasty success.

    PubMed

    Metin, Mehmet; Kaptan, Zeynep Kizilkaya; Dogan, Sedat; Yazici, Hasmet; Bayraktar, Cem; Gocmen, Hakan; Samim, Etem Erdal

    2014-01-01

    Purpose. This study was conducted with the aim of investigating the relationship between mastoid air cell volumes and graft success after tympanoplasty. Material and Methods. This study was performed retrospectively with patients undergoing type I tympanoplasty and antrostomy. A total of 57 patients (20-35.09% female and 37-64.91% male) with a mean age of 29.69 ± SD (range 12-56 years) were included in the study. The patients were invited for a control at the 1st, 3rd, and 12th months, and otoscopic examinations and audiometric tests were performed. The temporal bone computed tomography images were screened with the 4800 Dpi optic resolution scanner and transferred to the computer environment in JPG format in order to calculate the mastoid air cell volume, and the volumes were calculated using the Autocad 2007 program. Results. Although, the graft success was determined to be better in the well-ventilated group, no significant difference could be found between the groups in terms of graft success at the 1st, 3rd, and 12th months (P > 0.05). No statistically significant difference could be found between the three groups in terms of the preoperative and postoperative hearing gains (P > 0.05).

  8. A Preliminary Neuroimaging Study of Preschool Children with ADHD

    PubMed Central

    E.M., Mahone; D., Crocetti; M.E., Ranta; A., Gaddis; M., Cataldo; K.J., Slifer; M.B., Denckla; S.H., Mostofsky

    2012-01-01

    Attention-deficit/Hyperactivity Disorder (ADHD) is a developmental disorder which, by current definition, has onset prior to age 7 years. MRI studies have provided some insight into brain differences associated with ADHD, but thus far have almost exclusively focused on children ages 7 years and older. To better understand the neurobiological development of ADHD, cortical and subcortical brain development should be systematically examined in younger children presenting with symptoms of the disorder. High resolution anatomical (MPRAGE) images, acquired on a 3.0T scanner, were analyzed in a total of 26 preschoolers, ages 4–5 years (13 with ADHD, 13 controls, matched on age and sex). The ADHD sample was diagnosed using DSM-IV criteria, and screened for language disorders. Cortical regions were delineated and measured using automated methods in Freesurfer; basal ganglia structures were manually delineated. Children with ADHD showed significantly reduced caudate volumes bilaterally; in contrast, there were no significant group differences in cortical volume or thickness in this age range. After controlling for age and total cerebral volume, left caudate volume was a significant predictor of hyperactive/impulsive, but not inattentive symptom severity. Anomalous basal ganglia, particularly caudate, development appears to play an important role among children presenting with early onset symptoms of ADHD. PMID:21660881

  9. Screening assessment and requirements for a comprehensive assessment: Volume 1, Draft. Columbia River comprehensive impact assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-04-01

    To evaluate the impact to the Columbia River from the Hanford Site-derived contaminants, the U.S. Department of Energy, U.S. Environmental Protection Agency, and Washington State Department of Ecology initiated a study referred to as the Columbia River Comprehensive Impact Assessment (CRCIA). To address concerns about the scope and direction of CRCIA as well as enhance regulator, tribal, stockholder, and public involvement, the CRCIA Management Team was formed in August 1995. The Team agreed to conduct CRCIA using a phased approach. The initial phase, includes two components: 1) a screening assessment to evaluate the potential impact to the river, resulting frommore » current levels of Hanford-derived contaminants in order to support decisions on Interim Remedial Measures, and 2) a definition of the essential work remaining to provide an acceptable comprehensive river impact assessment. The screening assessment is described in Part I of this report. The essential work remaining is Part II of this report. The objective of the screening assessment is to identify areas where the greatest potential exists for adverse effects on humans or the environment. Part I of this report discusses the scope, technical approach, and results of the screening assessment. Part II defines a new paradigm for predecisional participation by those affected by Hanford cleanup decisions.« less

  10. Space shuttle/food system study. Volume 2, Appendix A: Active heating system-screening analysis. Appendix B: Reconstituted food heating techniques analysis

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Technical data are presented which were used to evaluate active heating methods to be incorporated into the space shuttle food system design, and also to evaluate the relative merits and penalties associated with various approaches to the heating of rehydrated food during space flight. Equipment heating candidates were subject to a preliminary screening performed by a selection rationale process which considered the following parameters; (1) gravitational effect; (2) safety; (3) operability; (4) system compatibility; (5) serviceability; (6) crew acceptability; (7) crew time; (8) development risk; and (9) operating cost. A hot air oven, electrically heated food tray, and microwave oven were selected for further consideration and analysis. Passive, semi-active, and active food preparation approaches were also studied in an effort to determine the optimum method for heating rehydrated food. Potential complexity, cost, vehicle impact penalties, and palatability were considered in the analysis. A summary of the study results is provided along with cost estimates for each of the potential sytems

  11. Long life assurance study for manned spacecraft long life hardware. Volume 4: Special long life assurance studies

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Guidelines for the selection of equipment to be used for manned spacecraft in order to assure a five year maintenance-free service life were developed. A special study was conducted to determine the adequacy of the procedures used to determine the quality and effectiveness of various components. The subjects examined are: (1) temperature cycling for acceptance of electronic assemblies; (2) accelerated testing techniques; (3) electronic part screening techniques; (4) electronic part derating practices; (5) vibration life extension of printed circuit board assemblies; and (6) tolerance funnelling and test requirements.

  12. Study and design of cryogenic propellant acquisition systems. Volume 1: Design studies

    NASA Technical Reports Server (NTRS)

    Burge, G. W.; Blackmon, J. B.

    1973-01-01

    An in-depth study and selection of practical propellant surface tension acquisition system designs for two specific future cryogenic space vehicles, an advanced cryogenic space shuttle auxiliary propulsion system and an advanced space propulsion module is reported. A supporting laboratory scale experimental program was also conducted to provide design information critical to concept finalization and selection. Designs using localized pressure isolated surface tension screen devices were selected for each application and preliminary designs were generated. Based on these designs, large scale acquisition prototype hardware was designed and fabricated to be compatible with available NASA-MSFC feed system hardware.

  13. Pulmonary function evaluation during and following Skylab space flights

    NASA Technical Reports Server (NTRS)

    Sawin, C. F.; Nicogossian, A. E.; Schachter, A. P.; Rummel, J. A.; Michel, E. L.

    1974-01-01

    Previous experience during the Apollo postflight exercise testing indicated no major changes in pulmonary function. Although pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic environments, few studies have dealt with normoxic environments at reduced total pressure as encountered during the Skylab missions. Forced vital capacity was measured during the preflight and postflight periods of the Skylab 2 mission. Initial in-flight measurements of vital capacity were obtained during the last two weeks of the second manned mission (Skylab 3). Comprehensive pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination, closing volume, vital capacity, and forced vital capacity and its derivatives. In addition, comprehensive in-flight vital capacity measurements were made during the Skylab 4 mission. Vital capacity was decreased slightly during flight in all Skylab 4 crewmen. No major preflight to postflight changes were observed in the other parameters.

  14. Regional variability in fecal microbiota transplantation practices: a survey of the Southern Ontario Fecal Microbiota Transplantation Movement.

    PubMed

    Hota, Susy S; Surangiwala, Salman; Paterson, Aimee S; Coburn, Bryan; Poutanen, Susan M

    2018-04-18

    There is growing evidence that fecal microbiota transplantation (FMT) is an effective treatment for recurrent Clostridium difficile infection, but little guidance exists for implementation of FMT programs. The objective of this study is to describe the program characteristics and protocols of 9 planned or operating FMT programs in the Southern Ontario Fecal Microbiota Transplantation (SOFT) Movement, to help guide future FMT program implementation. A 59-item survey was administered electronically to clinical leads of the SOFT Movement on June 2, 2016. The survey evaluated 7 domains: FMT program characteristics, FMT recipients, donor screening/selection, transplant manufacturing, FMT administration, good manufacturing procedures/biosafety procedures and infection-control procedures. We used descriptive statistics to analyze quantitative data. All 9 programs responded to the survey: 6 were active, 1 had FMT standard operating procedures developed but did not have clinical experience, and 2 were in the process of forming FMT programs. All 6 active programs performed FMT in adult patients with C. difficile infection. About 1300 FMT procedures were performed between 2003 and 2016. Five of the 6 operating programs administered the preparation via enema. Programs were driven primarily by physicians. All programs used universal FMT donors and followed Health Canada's screening guidelines, with considerable variability in screening frequency (every 3-6 mo) and modality. Locations for transplant preparation and manufacturing protocols varied across programs. Stool mass for FMT ranged from 20 g to 150 g, and transplant volume ranged from 25 mL to 300 mL. The experience of this high-volume regional FMT network highlights current challenges in FMT program development, including a high reliance on physicians and the costly nature of donor screening. Standardization and optimization through development of regional centres of excellence for FMT donor recruitment and administration should be explored. Copyright 2018, Joule Inc. or its licensors.

  15. Costs and Cost Effectiveness of Three Approaches for Cervical Cancer Screening among HIV-Positive Women in Johannesburg, South Africa

    PubMed Central

    Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S.; Firnhaber, Cindy

    2015-01-01

    Background South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Methods Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. Results VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Conclusions Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression. PMID:26569487

  16. Costs and Cost Effectiveness of Three Approaches for Cervical Cancer Screening among HIV-Positive Women in Johannesburg, South Africa.

    PubMed

    Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S; Firnhaber, Cindy

    2015-01-01

    South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression.

  17. Hippocampal atrophy in people with memory deficits: results from the population-based IPREA study.

    PubMed

    Ferrarini, Luca; van Lew, Baldur; Reiber, Johan H C; Gandin, Claudia; Galluzzo, Lucia; Scafato, Emanuele; Frisoni, Giovanni B; Milles, Julien; Pievani, Michela

    2014-07-01

    Clinical studies have shown that hippocampal atrophy is present before dementia in people with memory deficits and can predict dementia development. The question remains whether this association holds in the general population. This is of interest for the possible use of hippocampal atrophy to screen population for preventive interventions. The aim of this study was to assess hippocampal volume and shape abnormalities in elderly adults with memory deficits in a cross-sectional population-based study. We included individuals participating in the Italian Project on the Epidemiology of Alzheimer Disease (IPREA) study: 75 cognitively normal individuals (HC), 31 individuals with memory deficits (MEM), and 31 individuals with memory deficits not otherwise specified (MEMnos). Hippocampal volumes and shape were extracted through manual tracing and the growing and adaptive meshes (GAMEs) shape-modeling algorithm. We investigated between-group differences in hippocampal volume and shape, and correlations with memory deficits. In MEM participants, hippocampal volumes were significantly smaller than in HC and were mildly associated with worse memory scores. Memory-associated shape changes mapped to the anterior hippocampus. Shape-based analysis detected no significant difference between MEM and HC, while MEMnos showed shape changes in the posterior hippocampus compared with HC and MEM groups. These findings support the discriminant validity of hippocampal volumetry as a biomarker of memory impairment in the general population. The detection of shape changes in MEMnos but not in MEM participants suggests that shape-based biomarkers might lack sensitivity to detect Alzheimer's-like pathology in the general population.

  18. Defense Acquisition Research Journal. Volume 24, Number 1, Issue 80, January 2017

    DTIC Science & Technology

    2017-01-01

    call 703-960-6802 or 800-755-8805, or e-mail dauaa2@aol.com. ISSUE 80 JANUARY 2017 VOL. 24 NO. 1 1 We’re on the Web at: http://www.dau.mil...technical proposals, use white papers as an initial screen- ing process. The initial screening based solely on technical merit will help industry and...mda.mil) Dr. Thomas A . Mazzuchi is cha ir of the Department of Engineering Management and Systems Engineering in the School of Engineering and Applied

  19. Medical Surveillance Monthly Report (MSMR). Volume 22, Number 8, August 2015

    DTIC Science & Technology

    2015-08-01

    service after diagnoses of HIV -1 infections among active component members of the U.S. Armed Forces, 1990-2013 John F. Brundage, MD, MPH; Devin f...by ANSI Std Z39-18 MSMR Vol. 22 No. 8 August 2015 Page 2 of detection of HIV -2 infection cases by Service-specifi c screening programs, this...report will hereaft er refer to the target of the screening programs as simply “ HIV ” without specifying either of the types. Th is report summarizes

  20. SCREENING INFORMATION DATA SETS (SIDS)

    EPA Science Inventory

    The Organization for Economic Cooperation and Development (OECD) is jointly investigating international high production volume (HPV) chemicals. These HPV chemicals are defined as chemicals produced in one OECD Member country in quantities above10,000 metric tons (22 million lbs) ...

  1. Macromolecular Crystallization with Microfluidic Free-Interface Diffusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segelke, B

    2005-02-24

    Fluidigm released the Topaz 1.96 and 4.96 crystallization chips in the fall of 2004. Topaz 1.96 and 4.96 are the latest evolution of Fluidigm's microfluidics crystallization technologies that enable ultra low volume rapid screening for macromolecular crystallization. Topaz 1.96 and 4.96 are similar to each other but represent a major redesign of the Topaz system and have of substantially improved ease of automation and ease of use, improved efficiency and even further reduced amount of material needed. With the release of the new Topaz system, Fluidigm continues to set the standard in low volume crystallization screening which is having anmore » increasing impact in the field of structural genomics, and structural biology more generally. In to the future we are likely to see further optimization and increased utility of the Topaz crystallization system, but we are also likely to see further innovation and the emergence of competing technologies.« less

  2. Automatic machine learning based prediction of cardiovascular events in lung cancer screening data

    NASA Astrophysics Data System (ADS)

    de Vos, Bob D.; de Jong, Pim A.; Wolterink, Jelmer M.; Vliegenthart, Rozemarijn; Wielingen, Geoffrey V. F.; Viergever, Max A.; Išgum, Ivana

    2015-03-01

    Calcium burden determined in CT images acquired in lung cancer screening is a strong predictor of cardiovascular events (CVEs). This study investigated whether subjects undergoing such screening who are at risk of a CVE can be identified using automatic image analysis and subject characteristics. Moreover, the study examined whether these individuals can be identified using solely image information, or if a combination of image and subject data is needed. A set of 3559 male subjects undergoing Dutch-Belgian lung cancer screening trial was included. Low-dose non-ECG synchronized chest CT images acquired at baseline were analyzed (1834 scanned in the University Medical Center Groningen, 1725 in the University Medical Center Utrecht). Aortic and coronary calcifications were identified using previously developed automatic algorithms. A set of features describing number, volume and size distribution of the detected calcifications was computed. Age of the participants was extracted from image headers. Features describing participants' smoking status, smoking history and past CVEs were obtained. CVEs that occurred within three years after the imaging were used as outcome. Support vector machine classification was performed employing different feature sets using sets of only image features, or a combination of image and subject related characteristics. Classification based solely on the image features resulted in the area under the ROC curve (Az) of 0.69. A combination of image and subject features resulted in an Az of 0.71. The results demonstrate that subjects undergoing lung cancer screening who are at risk of CVE can be identified using automatic image analysis. Adding subject information slightly improved the performance.

  3. On the origin of enhanced sensitivity in nanoscale FET-based biosensors

    PubMed Central

    Shoorideh, Kaveh; Chui, Chi On

    2014-01-01

    Electrostatic counter ion screening is a phenomenon that is detrimental to the sensitivity of charge detection in electrolytic environments, such as in field-effect transistor-based biosensors. Using simple analytical arguments, we show that electrostatic screening is weaker in the vicinity of concave curved surfaces, and stronger in the vicinity of convex surfaces. We use this insight to show, using numerical simulations, that the enhanced sensitivity observed in nanoscale biosensors is due to binding of biomolecules in concave corners where screening is reduced. We show that the traditional argument, that increased surface area-to-volume ratio for nanoscale sensors is responsible for their increased sensitivity, is incorrect. PMID:24706861

  4. Next steps in addressing the prevention, screening, and treatment of substance use disorder in active duty and veteran Operation Enduring Freedom and Operation Iraqi Freedom populations.

    PubMed

    Tollison, Sean J; Henderson, Ryan C; Baer, Johns S; Saxon, Andrew J

    2012-08-01

    The two articles presented previously in this volume provide state-of-the-art reviews of the etiology, epidemiology, screening and treatment of substance use disorder (SUD). This article identifies next steps in research and development for understanding and treating SUD in Operation Enduring Freedom/Operation Iraqi Freedom service members and veterans. Four promising areas are reviewed: advances in psychopharmacological treatment of SUD, innovations in behavioral treatments, the use of technological advances for the screening and treatment of SUD, and integration of treatment services. Future directions are explored and suggestions for research, development and implementation of each of these trends are discussed.

  5. Quality of care and volume for patients with diabetes mellitus in the primary care setting: A population based retrospective cohort study.

    PubMed

    Wong, Carlos K H; Fung, Colman S C; Kung, Kenny; Wan, Eric Y F; Yu, Esther Y T; Chan, Anca K C; Lam, Cindy L K

    2016-10-01

    To examine the association of patient volume with quality of diabetes care in the primary care setting. We analyzed population-based data from Hospital Authority administrative database using a Hong Kong representative sample of 187,031 diabetic patients managed in 74 primary care general outpatient clinics between 04/2011 and 03/2012. We assessed the associations between annual clinic-based patient volume and quality of care in terms of adherence to care criteria of process (HbA1c test, renal function test, full lipid profile, urine protein analysis, diabetic retinopathy screening, and appropriate drug prescription) and clinical outcomes (HbA1c⩽7%, BP⩽130/80mmHg, LDL-C⩽2.6mmol/L) of care criteria, with and without adjustment for patient and clinic characteristics. Patient volume was associated with three of seven process of care criteria; however, when compared to clinics in higher volume quartiles, those in lowest-volume quartile had more odds of HbA1c test (odds ratios (OR): 0.781, 0.655 and 0.646 for quartile from 2 to 4, respectively), renal function test (OR: 0.357, 0.367 and 0.590 for quartile from 2 to 4, respectively), and full lipid profile test (OR: 0.508, 0.612 and 0.793 for quartile from 2 to 4, respectively). There was no significant association between patient volume and the standards of achieving of HbA1c, BP and LDL-C outcome targets. Disparities in volume and quality of diabetes care were observed in public primary care setting. Lower patient volumes at clinic level were associated with greater adherence to three process criteria but a volume-outcome association was not present. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Core compressor exit stage study. Volume 3: Data and performance report for screening test configurations

    NASA Technical Reports Server (NTRS)

    Wisler, D. C.

    1980-01-01

    Rear stage blading designs that have lower losses in their endwall boundary layer regions were developed. Test data and performance results for rotor B, stator B, and stator C - blading designs that offer promise of reducing endwall losses relative to the baseline are given. A low speed research compressor was the principal investigative tool. The tests were conducted using four identical stages of blading so that the test data would be obtained in a true multistage environment.

  7. Development of an all-metal thick film cost affective metallization system for solar cells

    NASA Technical Reports Server (NTRS)

    Ross, B.

    1981-01-01

    An economical thick film solar cell contact for high volume production of low cost silicon solar array modules was investigated. All metal screenable pastes using base metals were studied. Solar cells with junction depths varying by a factor of 3.3, with and without a deposited oxide coating were used. Cells were screened and fired by a two step firing process. Adhesion and metallurgical results are unsatisfactory. No electrical information is obtained due to inadequate contact adhesion.

  8. Research study on stellar X-ray imaging experiment, volume 1

    NASA Technical Reports Server (NTRS)

    Wilson, H. H.; Vanspeybroeck, L. P.

    1972-01-01

    The use of microchannel plates as focal plane readout devices and the evaluation of mirrors for X-ray telescopes applied to stellar X-ray imaging is discussed. The microchannel plate outputs were either imaged on a phosphor screen which was viewed by a low light level vidicon or on a wire array which was read out by digitally processing the output of a charge division network attached to the wires. A service life test which was conducted on two image intensifiers is described.

  9. Application of the Response Surface Methodology to Optimize the Fermentation Parameters for Enhanced Docosahexaenoic Acid (DHA) Production by Thraustochytrium sp. ATCC 26185.

    PubMed

    Wu, Kang; Ding, Lijian; Zhu, Peng; Li, Shuang; He, Shan

    2018-04-22

    The aim of this study was to determine the cumulative effect of fermentation parameters and enhance the production of docosahexaenoic acid (DHA) by Thraustochytrium sp. ATCC 26185 using response surface methodology (RSM). Among the eight variables screened for effects of fermentation parameters on DHA production by Plackett-Burman design (PBD), the initial pH, inoculum volume, and fermentation volume were found to be most significant. The Box-Behnken design was applied to derive a statistical model for optimizing these three fermentation parameters for DHA production. The optimal parameters for maximum DHA production were initial pH: 6.89, inoculum volume: 4.16%, and fermentation volume: 140.47 mL, respectively. The maximum yield of DHA production was 1.68 g/L, which was in agreement with predicted values. An increase in DHA production was achieved by optimizing the initial pH, fermentation, and inoculum volume parameters. This optimization strategy led to a significant increase in the amount of DHA produced, from 1.16 g/L to 1.68 g/L. Thraustochytrium sp. ATCC 26185 is a promising resource for microbial DHA production due to the high-level yield of DHA that it produces, and the capacity for large-scale fermentation of this organism.

  10. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting.

    PubMed

    van der Waal, Daniëlle; den Heeten, Gerard J; Pijnappel, Ruud M; Schuur, Klaas H; Timmers, Johanna M H; Verbeek, André L M; Broeders, Mireille J M

    2015-01-01

    The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation. Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50-75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]). Based on the BI-RADS classification, 40.8% of the women had 'heterogeneously or extremely dense' breasts. The median volumetric percent density was 12.1% (IQR: 9.6-16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4-10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04-5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra. Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized.

  11. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting

    PubMed Central

    van der Waal, Daniëlle; den Heeten, Gerard J.; Pijnappel, Ruud M.; Schuur, Klaas H.; Timmers, Johanna M. H.; Verbeek, André L. M.; Broeders, Mireille J. M.

    2015-01-01

    Introduction The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation. Materials and Methods Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50–75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]). Results Based on the BI-RADS classification, 40.8% of the women had ‘heterogeneously or extremely dense’ breasts. The median volumetric percent density was 12.1% (IQR: 9.6–16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4–10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04–5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra. Conclusion Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized. PMID:26335569

  12. Operationalizing hippocampal volume as an enrichment biomarker for amnestic mild cognitive impairment trials: effect of algorithm, test-retest variability, and cut point on trial cost, duration, and sample size.

    PubMed

    Yu, Peng; Sun, Jia; Wolz, Robin; Stephenson, Diane; Brewer, James; Fox, Nick C; Cole, Patricia E; Jack, Clifford R; Hill, Derek L G; Schwarz, Adam J

    2014-04-01

    The objective of this study was to evaluate the effect of computational algorithm, measurement variability, and cut point on hippocampal volume (HCV)-based patient selection for clinical trials in mild cognitive impairment (MCI). We used normal control and amnestic MCI subjects from the Alzheimer's Disease Neuroimaging Initiative 1 (ADNI-1) as normative reference and screening cohorts. We evaluated the enrichment performance of 4 widely used hippocampal segmentation algorithms (FreeSurfer, Hippocampus Multi-Atlas Propagation and Segmentation (HMAPS), Learning Embeddings Atlas Propagation (LEAP), and NeuroQuant) in terms of 2-year changes in Mini-Mental State Examination (MMSE), Alzheimer's Disease Assessment Scale-Cognitive Subscale (ADAS-Cog), and Clinical Dementia Rating Sum of Boxes (CDR-SB). We modeled the implications for sample size, screen fail rates, and trial cost and duration. HCV based patient selection yielded reduced sample sizes (by ∼40%-60%) and lower trial costs (by ∼30%-40%) across a wide range of cut points. These results provide a guide to the choice of HCV cut point for amnestic MCI clinical trials, allowing an informed tradeoff between statistical and practical considerations. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Association of increased total antioxidant capacity and anovulation in nonobese infertile patients with clomiphene citrate-resistant polycystic ovary syndrome.

    PubMed

    Verit, Fatma Ferda; Erel, Ozcan; Kocyigit, Abdurrahim

    2007-08-01

    To investigate whether total antioxidant capacity (TAC) could predict the response to ovulation induction to clomiphene citrate (CC) in nonobese women with polycystic ovary syndrome. Prospective longitudinal follow-up study. Academic hospital. Fifty-five nonobese, oligomenorrheic women with polycystic ovary syndrome and normal indices of insulin sensitivity. None. Standard clinical examinations and ultrasonographic and endocrine screening, including FSH, LH, E(2), P, total T, sex hormone-binding globulin, DHEAS, and TAC were performed before initiation of CC medication. Within the total group, 27 (49%) of the patients did not ovulate at the end of follow-up. TAC, free androgen index, and ovarian volume were all significantly different in CC nonresponders from those in responders. Total antioxidant capacity was found to be the best predictor in univariate analysis (odds ratio, 171.55; 95% confidence interval, 10.61-2,772.93), and it had the highest area in the receiver operating characteristics analysis (0.91). In a multivariate prediction model, TAC, free androgen index, and ovarian volume showed good predictive power, with Hosmer-Lemeshow goodness of fit test of 0.80. Total antioxidant capacity was the strongest predictor of ovarian response during CC induction of ovulation in these patients. It can be concluded that TAC can be used as a routine screening test.

  14. Discovery of Novel Human Epidermal Growth Factor Receptor-2 Inhibitors by Structure-based Virtual Screening.

    PubMed

    Shi, Zheng; Yu, Tian; Sun, Rong; Wang, Shan; Chen, Xiao-Qian; Cheng, Li-Jia; Liu, Rong

    2016-01-01

    Human epidermal growth factor receptor-2 (HER2) is a trans-membrane receptor like protein, and aberrant signaling of HER2 is implicated in many human cancers, such as ovarian cancer, gastric cancer, and prostate cancer, most notably breast cancer. Moreover, it has been in the spotlight in the recent years as a promising new target for therapy of breast cancer. Since virtual screening has become an integral part of the drug discovery process, it is of great significant to identify novel HER2 inhibitors by structure-based virtual screening. In this study, we carried out a series of elegant bioinformatics approaches, such as virtual screening and molecular dynamics (MD) simulations to identify HER2 inhibitors from Food and Drug Administration-approved small molecule drug as potential "new use" drugs. Molecular docking identified top 10 potential drugs which showed spectrum affinity to HER2. Moreover, MD simulations suggested that ZINC08214629 (Nonoxynol-9) and ZINC03830276 (Benzonatate) might exert potential inhibitory effects against HER2-targeted anti-breast cancer therapeutics. Together, our findings may provide successful application of virtual screening studies in the lead discovery process, and suggest that our discovered small molecules could be effective HER2 inhibitor candidates for further study. A series of elegant bioinformatics approaches, including virtual screening and molecular dynamics (MD) simulations were took advantage to identify human epidermal growth factor receptor-2 (HER2) inhibitors. Molecular docking recognized top 10 candidate compounds, which showed spectrum affinity to HER2. Further, MD simulations suggested that ZINC08214629 (Nonoxynol-9) and ZINC03830276 (Benzonatate) in candidate compounds were identified as potential "new use" drugs against HER2-targeted anti-breast cancer therapeutics. Abbreviations used: HER2: Human epidermal growth factor receptor-2, FDA: Food and Drug Administration, PDB: Protein Database Bank, RMSDs: Root mean square deviations, SPC: Single point charge, PME: Particle mesh Ewald, NVT: Constant volume, NPT: Constant pressure, RMSF: Root-mean-square fluctuation.

  15. Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Kohl, Gerhard; Klotz, Ernst; Heindel, Walter; Diederich, Stefan

    2002-05-01

    High reproducibility of volumetric measurements is an important prerequisite for follow-up of small lung nodules in order to differentiate malignant from benign lesions in a lung cancer screening setting. This study was aimed to evaluate the measurement reproducibility of a new software tool for pulmonary nodule volumetry. In an ongoing study, 147 pulmonary nodules (size 1.6-17.5 mm) were examined with low-dose multidetector CT (Siemens Somatom Volume Zoom, 120 kVp, 20 mAs, detector collimation 4x1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm). Two consecutive low-dose scans covering the whole lung volume were performed within a few minutes. Between both scans, patients were asked to leave the CT scanner, and the second scan was planned independently from the first one. For all visually detected pulmonary nodules with a diameter <20 mm nodule volume was determined on both scans using a software prototype containing segmentation and volumetry algorithms. Results from both scans were compared. Nodule volume differences were determined as difference between the first and second measurement and ranged from 169 to 87%. The performance of the diagnostic test was measured using ROC analysis. For the detection of a volume doubling the area under curve (Az) was 0.98, for a growth of 50% the Az was 0.89. Further refinement of the segmentation algorithm should lead to more consistent measurements in ill-defined nodules. In conclusion, volumetric measurement of pulmonary nodules in multislice CT data sets is a reliable tool for the detection of growth in small pulmonary nodules.

  16. 3D Convolutional Neural Network for Automatic Detection of Lung Nodules in Chest CT.

    PubMed

    Hamidian, Sardar; Sahiner, Berkman; Petrick, Nicholas; Pezeshk, Aria

    2017-01-01

    Deep convolutional neural networks (CNNs) form the backbone of many state-of-the-art computer vision systems for classification and segmentation of 2D images. The same principles and architectures can be extended to three dimensions to obtain 3D CNNs that are suitable for volumetric data such as CT scans. In this work, we train a 3D CNN for automatic detection of pulmonary nodules in chest CT images using volumes of interest extracted from the LIDC dataset. We then convert the 3D CNN which has a fixed field of view to a 3D fully convolutional network (FCN) which can generate the score map for the entire volume efficiently in a single pass. Compared to the sliding window approach for applying a CNN across the entire input volume, the FCN leads to a nearly 800-fold speed-up, and thereby fast generation of output scores for a single case. This screening FCN is used to generate difficult negative examples that are used to train a new discriminant CNN. The overall system consists of the screening FCN for fast generation of candidate regions of interest, followed by the discrimination CNN.

  17. 3D convolutional neural network for automatic detection of lung nodules in chest CT

    NASA Astrophysics Data System (ADS)

    Hamidian, Sardar; Sahiner, Berkman; Petrick, Nicholas; Pezeshk, Aria

    2017-03-01

    Deep convolutional neural networks (CNNs) form the backbone of many state-of-the-art computer vision systems for classification and segmentation of 2D images. The same principles and architectures can be extended to three dimensions to obtain 3D CNNs that are suitable for volumetric data such as CT scans. In this work, we train a 3D CNN for automatic detection of pulmonary nodules in chest CT images using volumes of interest extracted from the LIDC dataset. We then convert the 3D CNN which has a fixed field of view to a 3D fully convolutional network (FCN) which can generate the score map for the entire volume efficiently in a single pass. Compared to the sliding window approach for applying a CNN across the entire input volume, the FCN leads to a nearly 800-fold speed-up, and thereby fast generation of output scores for a single case. This screening FCN is used to generate difficult negative examples that are used to train a new discriminant CNN. The overall system consists of the screening FCN for fast generation of candidate regions of interest, followed by the discrimination CNN.

  18. Laboratory evaluation of alcohol safety interlock systems. Volume 2 : instrument screening experiments

    DOT National Transportation Integrated Search

    1974-01-01

    The report contains the results of an experimental and analytical evaluation of instruments and techniques designed to prevent an intoxicated driver from operating his automobile. The prototype 'Alcohol Safety Interlock Systems' tested were developed...

  19. Strategies to manage hepatitis C virus infection disease burden - volume 3.

    PubMed

    Alfaleh, F Z; Nugrahini, N; Matičič, M; Tolmane, I; Alzaabi, M; Hajarizadeh, B; Valantinas, J; Kim, D Y; Hunyady, B; Abaalkhail, F; Abbas, Z; Abdou, A; Abourached, A; Al Braiki, F; Al Hosani, F; Al Jaberi, K; Al Khatry, M; Al Mulla, M A; Al Quraishi, H; Al Rifai, A; Al Serkal, Y; Alam, A; Alashgar, H I; Alavian, S M; Alawadhi, S; Al-Dabal, L; Aldins, P; Alghamdi, A S; Al-Hakeem, R; Aljumah, A A; Almessabi, A; Alqutub, A N; Alswat, K A; Altraif, I; Andrea, N; Assiri, A M; Babatin, M A; Baqir, A; Barakat, M T; Bergmann, O M; Bizri, A R; Chaudhry, A; Choi, M S; Diab, T; Djauzi, S; El Hassan, E S; El Khoury, S; Estes, C; Fakhry, S; Farooqi, J I; Fridjonsdottir, H; Gani, R A; Ghafoor Khan, A; Gheorghe, L; Goldis, A; Gottfredsson, M; Gregorcic, S; Gunter, J; Hamid, S; Han, K H; Hasan, I; Hashim, A; Horvath, G; Husni, R; Jafri, W; Jeruma, A; Jonasson, J G; Karlsdottir, B; Kim, Y S; Koutoubi, Z; Lesmana, L A; Liakina, V; Lim, Y S; Löve, A; Maimets, M; Makara, M; Malekzadeh, R; Memon, M S; Merat, S; Mokhbat, J E; Mourad, F H; Muljono, D H; Nawaz, A; Olafsson, S; Priohutomo, S; Qureshi, H; Rassam, P; Razavi, H; Razavi-Shearer, D; Razavi-Shearer, K; Rozentale, B; Sadik, M; Saeed, K; Salamat, A; Salupere, R; Sanai, F M; Sanityoso Sulaiman, A; Sayegh, R A; Schmelzer, J D; Sharara, A I; Sibley, A; Siddiq, M; Siddiqui, A M; Sigmundsdottir, G; Sigurdardottir, B; Speiciene, D; Sulaiman, A; Sultan, M A; Taha, M; Tanaka, J; Tarifi, H; Tayyab, G; Ud Din, M; Umar, M; Videčnik-Zorman, J; Yaghi, C; Yunihastuti, E; Yusuf, M A; Zuberi, B F; Blach, S

    2015-12-01

    The hepatitis C virus (HCV) epidemic was forecasted through 2030 for 15 countries in Europe, the Middle East and Asia, and the relative impact of two scenarios was considered: increased treatment efficacy while holding the annual number of treated patients constant and increased treatment efficacy and an increased annual number of treated patients. Increasing levels of diagnosis and treatment, in combination with improved treatment efficacy, were critical for achieving substantial reductions in disease burden. A 90% reduction in total HCV infections within 15 years is feasible in most countries studied, but it required a coordinated effort to introduce harm reduction programmes to reduce new infections, screening to identify those already infected and treatment with high cure rate therapies. This suggests that increased capacity for screening and treatment will be critical in many countries. Birth cohort screening is a helpful tool for maximizing resources. Among European countries, the majority of patients were born between 1940 and 1985. A wider range of birth cohorts was seen in the Middle East and Asia (between 1925 and 1995). © 2015 John Wiley & Sons Ltd.

  20. Screening the Hanford tanks for trapped gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitney, P.

    1995-10-01

    The Hanford Site is home to 177 large, underground nuclear waste storage tanks. Hydrogen gas is generated within the waste in these tanks. This document presents the results of a screening of Hanford`s nuclear waste storage tanks for the presence of gas trapped in the waste. The method used for the screening is to look for an inverse correlation between waste level measurements and ambient atmospheric pressure. If the waste level in a tank decreases with an increase in ambient atmospheric pressure, then the compressibility may be attributed to gas trapped within the waste. In this report, this methodology ismore » not used to estimate the volume of gas trapped in the waste. The waste level measurements used in this study were made primarily to monitor the tanks for leaks and intrusions. Four measurement devices are widely used in these tanks. Three of these measure the level of the waste surface. The remaining device measures from within a well embedded in the waste, thereby monitoring the liquid level even if the liquid level is below a dry waste crust. In the past, a steady rise in waste level has been taken as an indicator of trapped gas. This indicator is not part of the screening calculation described in this report; however, a possible explanation for the rise is given by the mathematical relation between atmospheric pressure and waste level used to support the screening calculation. The screening was applied to data from each measurement device in each tank. If any of these data for a single tank indicated trapped gas, that tank was flagged by this screening process. A total of 58 of the 177 Hanford tanks were flagged as containing trapped gas, including 21 of the 25 tanks currently on the flammable gas watch list.« less

  1. A universal array-based multiplexed test for cystic fibrosis carrier screening.

    PubMed

    Amos, Jean A; Bridge-Cook, Philippa; Ponek, Victor; Jarvis, Michael R

    2006-01-01

    Cystic fibrosis is a multisystem autosomal recessive disorder with high carrier frequencies in caucasians and significant, but lower, carrier frequencies in other ethnicities. Based on technology that allows high detection of mutations in caucasians and significant detection in other ethnic groups, the American College of Medical Genetics (ACMG) and American College of Obstetricians and Gynecologists (ACOG) have recommended pan-ethnic cystic fibrosis carrier screening for all reproductive couples. This paper discusses carrier screening using the Tag-It multiplex mutation platform and the Cystic Fibrosis Mutation Detection Kit. The Tag-It cystic fibrosis assay is a multiplexed genotyping assay that detects a panel of 40 cystic fibrosis transmembrane conductance regulator mutations including the 23 mutations recommended by the ACMG and ACOG for population screening. A total of 16 additional mutations detected by the Tag-It cystic fibrosis assay may also be common. The assay method is described in detail, and its performance in a genetics reference laboratory performing high-volume cystic fibrosis carrier screening is assessed.

  2. How quickly do breast screeners learn their skills?

    NASA Astrophysics Data System (ADS)

    Nevisi, Hossein; Dong, Leng; Chen, Yan; Gale, Alastair G.

    2017-03-01

    The UK's Breast Screening Programme is 27 years old and many experienced breast radiologists are now retiring, coupled with an influx of new screening personnel. It is important to the ongoing Programme that new mammography readers are quickly up to the skill level of experienced readers. This raises the question of how quickly the necessary cancer detection skills are learnt. All breast screening radiologists in the UK read educational training sets of challenging FFDM images (the PERFORMS® scheme) yearly to maintain and improve their performance in real life screening. Data were examined from the PERFORMS® annual scheme for 54 new screeners, 55 screeners who have been screening for one year and also for more experienced screeners (597 screeners). Not surprisingly, significant differences in cancer detection rate were found between new readers and both of the other groups. Additionally, the performance of 48 new readers who have now been screening for about a year and have taken part twice in the PERFORMS® scheme were further examined where again a significant difference in cancer detection was found. These data imply that cancer detection skills are learnt quickly in the first year of screening. Information was also examined concerning the volume of cases participants read and other factors.

  3. A Cross-sectional Analysis of Minimum USMLE Step 1 and 2 Criteria Used by Orthopaedic Surgery Residency Programs in Screening Residency Applications.

    PubMed

    Schrock, John B; Kraeutler, Matthew J; Dayton, Michael R; McCarty, Eric C

    2017-06-01

    The purpose of this study was to analyze how program directors (PDs) of orthopaedic surgery residency programs use United States Medical Licensing Examination (USMLE) Step 1 and 2 scores in screening residency applicants. A survey was sent to each allopathic orthopaedic surgery residency PD. PDs were asked if they currently use minimum Step 1 and/or 2 scores in screening residency applicants and if these criteria have changed in recent years. Responses were received from 113 of 151 PDs (75%). One program did not have the requested information and five declined participation, leaving 107 responses analyzed. Eighty-nine programs used a minimum USMLE Step 1 score (83%). Eighty-three programs (78%) required a Step 1 score ≥210, 80 (75%) required a score ≥220, 57 (53%) required a score ≥230, and 22 (21%) required a score ≥240. Multiple PDs mentioned the high volume of applications as a reason for using a minimum score and for increasing the minimum score in recent years. A large proportion of orthopaedic surgery residency PDs use a USMLE Step 1 minimum score when screening applications in an effort to reduce the number of applications to be reviewed.

  4. Parts, materials, and processes experience summary, volume 2. [design, engineering, and quality control

    NASA Technical Reports Server (NTRS)

    1973-01-01

    This summary provides the general engineering community with the accumulated experience from ALERT reports issued by NASA and the Government-Industry. Data Exchange Program, and related experience gained by Government and industry. It provides expanded information on selected topics by relating the problem area (failure) to the cause, the investigation and findings, the suggestions for avoidance (inspections, screening tests, proper part applications, requirements for manufacturer's plant facilities, etc.), and failure analysis procedures. Diodes, integrated circuits, and transistors are covered in this volume.

  5. Calculation of the capnographic index based on expiratory molar mass-volume-curves--a suitable tool to screen for cystic fibrosis lung disease.

    PubMed

    Fuchs, Susanne I; Junge, Sibylle; Ellemunter, Helmut; Ballmann, Manfred; Gappa, Monika

    2013-05-01

    Volumetric capnography reflecting the course of CO2-exhalation is used to assess ventilation inhomogeneity. Calculation of the slope of expiratory phase 3 and the capnographic index (KPIv) from expirograms allows quantification of extent and severity of small airway impairment. However, technical limitations have hampered more widespread use of this technique. Using expiratory molar mass-volume-curves sampled with a handheld ultrasonic flow sensor during tidal breathing is a novel approach to extract similar information from expirograms in a simpler manner possibly qualifying as a screening tool for clinical routine. The aim of the present study was to evaluate calculation of the KPIv based on molar mass-volume-curves sampled with an ultrasonic flow sensor in patients with CF and controls by assessing feasibility, reproducibility and comparability with the Lung Clearance Index (LCI) derived from multiple breath washout (MBW) used as the reference method. Measurements were performed in patients with CF and healthy controls during a single test occasion using the EasyOne Pro, MBW Module (ndd Medical Technologies, Switzerland). Capnography and MBW were performed in 87/96 patients with CF and 38/42 controls, with a success rate of 90.6% for capnography. Mean age (range) was 12.1 (4-25) years. Mean (SD) KPIv was 6.94 (3.08) in CF and 5.10 (2.06) in controls (p=0.001). Mean LCI (SD) was 8.0 (1.4) in CF and 6.2 (0.4) in controls (p=<0.001) and correlated significantly with the KPIv (p=<0.001). Calculation of the KPIv based on molar mass-volume-curves is feasible. KPIv is significantly different between patients with CF and controls and correlates with the LCI. However, individual data revealed a relevant overlap between patients and controls requiring further evaluation, before this method can be recommended for clinical use. Copyright © 2012 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  6. Two-stage preconcentrator for vapor/particle detection

    DOEpatents

    Linker, Kevin L.; Brusseau, Charles A.

    2002-01-01

    A device for concentrating particles from a high volume gas stream and delivering the particles for detection in a low volume gas stream includes first and second preconcentrators. The first preconcentrator has a first structure for retaining particles in a first gas flow path through which a first gas flows at a relatively high volume, valves for selectively stopping the first gas flow; and a second gas flow path through which gas flows at an intermediate flow volume for moving particles from the first structure. The second preconcentrator includes a second structure for retaining particles in the second gas flow path; a valve for selectively stopping the second gas flow; and a third gas flow path through which gas flows at a low volume for moving particles from the second structure to a detector. Each of the particle retaining structures is preferably a metal screen that may be resistively heated by application of an electric potential to release the particles.

  7. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    PubMed

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  8. Model driver screening and evaluation program. Volume 3, Guidelines for motor vehicle administrators

    DOT National Transportation Integrated Search

    2003-05-01

    These Guidelines present an update of report number DOT HS 807 853 published in August 1992. They reflect current understanding of the relationship between functional capabilities and driving impairment gained through review of existing medical revie...

  9. Immunotoxicant Screening and Prioritization in the 21st Century**

    EPA Science Inventory

    Current immunotoxicity testing guidance for drugs, high production volume chemicals and pesticides specifies the use of animal models to assess potential biomarkers of immune system effects (e.g., lymphoid organ and bone marrow indices, histopathology) or actual measures of immun...

  10. Volume balance and toxicity analysis for the cross lake bridge.

    DOT National Transportation Integrated Search

    2009-09-01

    There were two overall objectives for this project: (1) to assess leakage from the bridge once repairs to the collection system were completed and (2) to investigate Microtox, a toxicity screening tool manufactured by Azur environmental, as a m...

  11. Immunotoxicant screening and prioritization in the 21st century

    EPA Science Inventory

    Current immunotoxicity testing guidance for drugs, high production volume chemicals and pesticides specifies the use of animal models that measure immune function or evaluation of general indicators of immune system health generated in routine toxicity testing. The assays are ...

  12. Immunotoxicant screening and prioritization in the 21st century*

    EPA Science Inventory

    Current immunotoxicity testing guidance for drugs, high production volume chemicals and pesticides specifies the use of animal models that measure immune function or evaluation of general indicators of immune system health generated in routine toxicity testing. The assays are r...

  13. New Insight from Using Spatiotemporal Image Correlation in Prenatal Screening of Fetal Conotruncal Defects

    PubMed Central

    Xie, Zuo-ping; Zhao, Bo-wen; Yuan, Hua; Hua, Qi-qi; Jin, She-hong; Shen, Xiao-yan; Han, Xin-hong; Zhou, Jia-mei; Fang, Min; Chen, Jin-hong

    2013-01-01

    Background: To establish the reference range of the angle between ascending aorta and main pulmonary artery of fetus in the second and third trimester using spatiotemporal image correlation (STIC), and to investigate the value of this angle in prenatal screening of conotruncal defects (CTDs). Materials and Methods: Volume images of 311 normal fetuses along with 20 fetuses with congenital heart diseases were recruited in this cross-sectional study. An offline analysis of acquired volume datasets was carried out with multiplanar mode. The angle between aorta and pulmonary artery was measured by navigating the pivot point and rotating axes and the reference range was established. The images of ascending aorta and main pulmonary artery in fetuses with congenital heart diseases were observed by rotating the axes within the normal angle reference range. Results: The angle between ascending aorta and main pulmonary artery of the normal fetus (range: 59.1˚~97.0˚, mean ± SD: 78.0˚ ± 9.7˚) was negatively correlated with gestational age (r = -0.52; p<0.01). By rotating the normal angle range corresponding to gestational age, the fetuses with CTD could not display views of their left ventricular long axis and main pulmonary trunk correctly. Conclusion: The left ventricular long axis and main pulmonary trunk views can be displayed using STIC so that the echocardiographic protocol of the cardiovascular joint could be standardized. The reference range of the angle between ascending aorta and main pulmonary artery is clinically useful in prenatal screening of CTD and provides a reliable quantitative standard to estimate the spatial relationship of the large arteries of fetus. PMID:24520485

  14. Staphylococcus aureus DNA ligase: characterization of its kinetics of catalysis and development of a high-throughput screening compatible chemiluminescent hybridization protection assay.

    PubMed

    Gul, Sheraz; Brown, Richard; May, Earl; Mazzulla, Marie; Smyth, Martin G; Berry, Colin; Morby, Andrew; Powell, David J

    2004-11-01

    DNA ligases are key enzymes involved in the repair and replication of DNA. Prokaryotic DNA ligases uniquely use NAD+ as the adenylate donor during catalysis, whereas eukaryotic enzymes use ATP. This difference in substrate specificity makes the bacterial enzymes potential targets for therapeutic intervention. We have developed a homogeneous chemiluminescence-based hybridization protection assay for Staphylococcus aureus DNA ligase that uses novel acridinium ester technology and demonstrate that it is an alternative to the commonly used radiometric assays for ligases. The assay has been used to determine a number of kinetic constants for S. aureus DNA ligase catalysis. These included the K(m) values for NAD+ (2.75+/-0.1 microM) and the acridinium-ester-labelled DNA substrate (2.5+/-0.2 nM). A study of the pH-dependencies of kcat, K(m) and kcat/K(m) has revealed values of kinetically influential ionizations within the enzyme-substrate complexes (kcat) and free enzyme (kcat/K(m)). In each case, the curves were shown to be composed of one kinetically influential ionization, for k(cat), pK(a)=6.6+/-0.1 and kcat/K(m), pK(a)=7.1+/-0.1. Inhibition characteristics of the enzyme against two Escherichia coli DNA ligase inhibitors have also been determined with IC50 values for these being 3.30+/-0.86 microM for doxorubicin and 1.40+/-0.07 microM for chloroquine diphosphate. The assay has also been successfully miniaturized to a sufficiently low volume to allow it to be utilized in a high-throughput screen (384-well format; 20 microl reaction volume), enabling the assay to be used in screening campaigns against libraries of compounds to discover leads for further drug development.

  15. Vasculature surrounding a nodule: A novel lung cancer biomarker.

    PubMed

    Wang, Xiaohua; Leader, Joseph K; Wang, Renwei; Wilson, David; Herman, James; Yuan, Jian-Min; Pu, Jiantao

    2017-12-01

    To investigate whether the vessels surrounding a nodule depicted on non-contrast, low-dose computed tomography (LDCT) can discriminate benign and malignant screen detected nodules. We collected a dataset consisting of LDCT scans acquired on 100 subjects from the Pittsburgh Lung Screening study (PLuSS). Fifty subjects were diagnosed with lung cancer and 50 subjects had suspicious nodules later proven benign. For the lung cancer cases, the location of the malignant nodule in the LDCT scans was known; while for the benign cases, the largest nodule in the LDCT scan was used in the analysis. A computer algorithm was developed to identify surrounding vessels and quantify the number and volume of vessels that were connected or near the nodule. A nonparametric receiver operating characteristic (ROC) analysis was performed based on a single nodule per subject to assess the discriminability of the surrounding vessels to provide a lung cancer diagnosis. Odds ratio (OR) were computed to determine the probability of a nodule being lung cancer based on the vessel features. The areas under the ROC curves (AUCs) for vessel count and vessel volume were 0.722 (95% CI=0.616-0.811, p<0.01) and 0.676 (95% CI=0.565-0.772), respectively. The number of vessels attached to a nodule was significantly higher in the lung cancer group 9.7 (±9.6) compared to the non-lung cancer group 4.0 (±4.3) CONCLUSION: Our preliminary results showed that malignant nodules are often surrounded by more vessels compared to benign nodules, suggesting that the surrounding vessel characteristics could serve as lung cancer biomarker for indeterminate nodules detected during LDCT lung cancer screening using only the information collected during the initial visit. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Racial Differences in Quantitative Measures of Area and Volumetric Breast Density

    PubMed Central

    McCarthy, Anne Marie; Keller, Brad M.; Pantalone, Lauren M.; Hsieh, Meng-Kang; Synnestvedt, Marie; Conant, Emily F.; Armstrong, Katrina; Kontos, Despina

    2016-01-01

    Abstract Background: Increased breast density is a strong risk factor for breast cancer and also decreases the sensitivity of mammographic screening. The purpose of our study was to compare breast density for black and white women using quantitative measures. Methods: Breast density was assessed among 5282 black and 4216 white women screened using digital mammography. Breast Imaging-Reporting and Data System (BI-RADS) density was obtained from radiologists’ reports. Quantitative measures for dense area, area percent density (PD), dense volume, and volume percent density were estimated using validated, automated software. Breast density was categorized as dense or nondense based on BI-RADS categories or based on values above and below the median for quantitative measures. Logistic regression was used to estimate the odds of having dense breasts by race, adjusted for age, body mass index (BMI), age at menarche, menopause status, family history of breast or ovarian cancer, parity and age at first birth, and current hormone replacement therapy (HRT) use. All statistical tests were two-sided. Results: There was a statistically significant interaction of race and BMI on breast density. After accounting for age, BMI, and breast cancer risk factors, black women had statistically significantly greater odds of high breast density across all quantitative measures (eg, PD nonobese odds ratio [OR] = 1.18, 95% confidence interval [CI] = 1.02 to 1.37, P = .03, PD obese OR = 1.26, 95% CI = 1.04 to 1.53, P = .02). There was no statistically significant difference in BI-RADS density by race. Conclusions: After accounting for age, BMI, and other risk factors, black women had higher breast density than white women across all quantitative measures previously associated with breast cancer risk. These results may have implications for risk assessment and screening. PMID:27130893

  17. Determination of the Chronic Mammalian Toxicological Effects of TNT (twenty-Four Month Chronic Toxicity/Carcinogenicity Study of Trinitrotoluene (TNT) in the B6C3F1 Hybrid Mouse). Volume 1

    DTIC Science & Technology

    1984-12-01

    chemistry parameters (see section l1.D.) Results of pretreatment health screen were within limits for the mice of this strain and age. Microbiological ...negative as measured by Microbiological Associates, Bethesda MD. Animals received 5002 rodent chow from arrival urtil their termina~lon, except during a...CARCINOGENICITY STUDY OF FRINITROTOLUENE IN THE B6C3FI MOUSE. ’EST DIET CONCENTRATION OF TNT TESI DOSE % % A x 100 - K!E!Th (mg,/kg/day) SEX INTENDED ANALYSED REL

  18. Functionality screen of streptavidin mutants by non-denaturing SDS-PAGE using biotin-4-fluorescein.

    PubMed

    Humbert, Nicolas; Ward, Thomas R

    2008-01-01

    Site-directed mutagenesis or directed evolution of proteins often leads to the production of inactive mutants. For streptavidin and related proteins, mutations may lead to the loss of their biotin-binding properties. With high-throughput screening methodologies in mind, it is imperative to detect, prior to the high-density protein production, the bacteria that produce non-functional streptavidin isoforms. Based on the incorporation of biotin-4-fluorescein in streptavidin mutants present in Escherichia coli bacterial extracts, we detail a functional screen that allows the identification of biotin-binding streptavidin variants. Bacteria are cultivated in a small volume, followed by a rapid treatment of the cells; biotin-4-fluorescein is added to the bacterial extract and loaded on an Sodium Dodecyl Sulfate Poly-Acrylamide Gel Electrophoresis (SDS-PAGE) under non-denaturing conditions. Revealing is performed using a UV transilluminator. This screen is thus easy to implement, cheap and requires only readily available equipment.

  19. Optimization of cultivation conditions of fermented shaggy ink cap culinary-medicinal mushroom, Coprinus comatus (O.Mull.:Fr.) Pers. (higher Basidiomycetes) rich in Vanadium.

    PubMed

    Zhang, Chunjing; Qi, Xiaodan; Shi, Yan; Sun, Yan; Li, Shuyan; Gao, Xiulan; Yu, Haitao

    2012-01-01

    The present paper is mainly aimed at optimization of cultivation conditions of fermented mushrooms of Coprinus comatus rich in vanadium (CCRV). Initial screening of effects of carbon source, temperature, pH, and inoculum size were done by using a one-factor-at-a-time method. The results obtained in that study showed that the optimal medium composition was 30 g glucose/Lin YEPG medium, initial pH 6.0, inoculum volume 10%, and incubation time 120 h. Then the medium was subjected to screening of the most significant parameters using the L9 orthogonal array to solve multivariable equations simultaneously. The results obtained in this study showed that the optimal medium composition was 0.4% V and 30 g glucose/Lin YEPG medium, initial pH 5.0, inoculum volume 15%, and incubation time 120 h. At this medium composition, the mycelial biomass and V content were 7.18 ± 0.24 g/L and 3786.0 ± 17 μg/g, respectively. The anti-diabetic potential of CCRV produced with the optimal level was tested in alloxan-induced diabetes. After the mice were administered (i.g.) with CCRV, the level of blood sugar in the CCRV group was very close to that of the control group. These findings suggested that CCRV produced with the optimal level is useful in the control of diabetes mellitus.

  20. On short-term memory of prefrontal cortex using near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Chengjun; Gan, Zhuo; Gong, Hui; Luo, Qingming; Zeng, Shaoqun

    2003-12-01

    For studying prefrontal cortical function in short-term memory two tasks were designed. In task one, a plus expression appears on screen for 300 milliseconds every other 2 seconds and the subject is required to give it"s answer but not to remember it. In task two, an Arabic numeral presents on screen as the same frequency as in task one. While a number is present, the subject need adding it to the sum he got last time. As subjects, 26 children participated in the work. Blood volume changes(BVCs) of right prefrontal cortex(PC) under two cognitive tasks were examined using functional near infrared imaging(fNIRI), a noninvasive technique for localizing regional BVCs which correlate with neural activities. The BVCs caused by short-term memory for numbers were retrieved from BVCs by task one and task two. Results revealed that short-term memory is related to PC and the near-infrared spectroscopy(NIRS) can be used to study prefrontal cortical function in short-term memory.

  1. A simple ergonomic measure reduces fluoroscopy time during ERCP: A multivariate analysis.

    PubMed

    Jowhari, Fahd; Hopman, Wilma M; Hookey, Lawrence

    2017-03-01

    Background and study aims  Endoscopic retrograde cholangiopancreatgraphy (ERCP) carries a radiation risk to patients undergoing the procedure and the team performing it. Fluoroscopy time (FT) has been shown to have a linear relationship with radiation exposure during ERCP. Recent modifications to our ERCP suite design were felt to impact fluoroscopy time and ergonomics. This multivariate analysis was therefore undertaken to investigate these effects, and to identify and validate various clinical, procedural and ergonomic factors influencing the total fluoroscopy time during ERCP. This would better assist clinicians with predicting prolonged fluoroscopic durations and to undertake relevant precautions accordingly. Patients and methods  A retrospective analysis of 299 ERCPs performed by 4 endoscopists over an 18-month period, at a single tertiary care center was conducted. All inpatients/outpatients (121 males, 178 females) undergoing ERCP for any clinical indication from January 2012 to June 2013 in the chosen ERCP suite were included in the study. Various predetermined clinical, procedural and ergonomic factors were obtained via chart review. Univariate analyses identified factors to be included in the multivariate regression model with FT as the dependent variable. Results  Bringing the endoscopy and fluoroscopy screens next to each other was associated with a significantly lesser FT than when the screens were separated further (-1.4 min, P  = 0.026). Other significant factors associated with a prolonged FT included having a prior ERCP (+ 1.4 min, P  = 0.031), and more difficult procedures (+ 4.2 min for each level of difficulty, P  < 0.001). ERCPs performed by high-volume endoscopists used lesser FT vs. low-volume endoscopists (-1.82, P = 0.015). Conclusions  Our study has identified and validated various factors that affect the total fluoroscopy time during ERCP. This is the first study to show that decreasing the distance between the endoscopy and fluoroscopy screens in the ERCP suite significantly reduces the total fluoroscopy time, and therefore radiation exposure to patients and staff involved in the procedure.

  2. Evaluation of Quantitative Environmental Stress Screening (ESS) Methods. Volume 1

    DTIC Science & Technology

    1991-11-01

    required information on screening strength from the curvefitting parameters. The underlying theory and approach taken are discussed in Appendix A. To...in field 1020 arm St.,Vas AJ Ptr 0.4i Currpnt. c- ugt ~ing DU?/SYS 2.7264 Wll/IY.3 at Factory Stress- NaxiLMw outgoing W?is’ys 0.288 DrW/5?S at Field...182 125 K.W.Fertig and V.X. Murthy, Models for Reliability Growth During Burn-in: Theory and Applicat’ons,Proceedings 1978 Annual Reliability and

  3. Volumetric 3D Display System with Static Screen

    NASA Technical Reports Server (NTRS)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous approaches, so there is no image jitter, and has an inherent parallel mechanism for 3D voxel addressing. High spatial resolution is possible with a full color display being easy to implement. The system is low-cost and low-maintenance.

  4. [Contamination of human milk with aerobic flora: Evaluation of losses for a human milk bank].

    PubMed

    Dewitte, C; Courdent, P; Charlet, C; Dumoulin, D; Courcol, R; Pierrat, V

    2015-05-01

    In France, human milk banks pasteurize milk for the mother's own hospitalized baby (personalized milk) and for donation. There is specific legislation regulating the activity of human milk banks with bacterial screening of donor milk before and after pasteurization. Milk should be tested for Staphylococcus aureus and total aerobic flora. Any sample of milk positive for aerobic flora and/or S. aureus before and/or after pasteurization should be discarded. The real pathogenicity of the total aerobic flora is actually debated as well as the usefulness of systematic postpasteurization screening. The aim of this study was to quantify milk losses related to prepasteurization contamination by total aerobic flora in a regional milk bank, to identify losses due to contamination with S. aureus or aerobic flora, and to analyze differences between centers. This was a prospective observational study conducted in the regional human milk bank of the Nord-Pas-de-Calais area in France. Data were collected from six major centers providing 80% of the milk collected between June 2011 and June 2012. Variables were the volumes of personalized milk collected by each center, volumes of contaminated milk, and the type of bacteria identified. During the study period, the regional human milk bank treated 4715 L (liters) of personalized milk and 508 L (10.8%) were discarded due to bacteriological screening. Among these 508 L, 43% were discarded because of a prepasteurization contamination with aerobic flora, 55% because of a prepasteurization contamination with S. aureus, and 2% because of other pathogenic bacteria. Postpasteurization tests were positive in 25 samples (0.5%). Only five of these 25 samples were positive before pasteurization and in all cases with S. aureus. A total of 218 L were destroyed because of prepasteurization contamination with total aerobic flora, while the postpasteurization culture was sterile. There was a great difference between centers in the percentage of discarded milk and the type of contamination. The percentage of discarded milk varied from 4 to 16% (P<0.001) and the percentage of prepasteurization positive samples with aerobic flora from 0 to 70% (P<0.001). Costing 80 €/L in France, this represented an economic loss of €17,440. A significant volume of milk is discarded because of contamination with total aerobic flora found only in prepasteurization tests. Reassessment of the French regulations with regard to microbiological safety could save human milk to cover the needs of a larger group of preterm babies. Copyright © 2015. Published by Elsevier SAS.

  5. Superhydrophilic-Superhydrophobic Patterned Surfaces as High-Density Cell Microarrays: Optimization of Reverse Transfection.

    PubMed

    Ueda, Erica; Feng, Wenqian; Levkin, Pavel A

    2016-10-01

    High-density microarrays can screen thousands of genetic and chemical probes at once in a miniaturized and parallelized manner, and thus are a cost-effective alternative to microwell plates. Here, high-density cell microarrays are fabricated by creating superhydrophilic-superhydrophobic micropatterns in thin, nanoporous polymer substrates such that the superhydrophobic barriers confine both aqueous solutions and adherent cells within each superhydrophilic microspot. The superhydrophobic barriers confine and prevent the mixing of larger droplet volumes, and also control the spreading of droplets independent of the volume, minimizing the variability that arises due to different liquid and surface properties. Using a novel liposomal transfection reagent, ScreenFect A, the method of reverse cell transfection is optimized on the patterned substrates and several factors that affect transfection efficiency and cytotoxicity are identified. Higher levels of transfection are achieved on HOOC- versus NH 2 -functionalized superhydrophilic spots, as well as when gelatin and fibronectin are added to the transfection mixture, while minimizing the amount of transfection reagent improves cell viability. Almost no diffusion of the printed transfection mixtures to the neighboring microspots is detected. Thus, superhydrophilic-superhydrophobic patterned surfaces can be used as cell microarrays and for optimizing reverse cell transfection conditions before performing further cell screenings. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Airborne chemistry: acoustic levitation in chemical analysis.

    PubMed

    Santesson, Sabina; Nilsson, Staffan

    2004-04-01

    This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.

  7. High pressure and high temperature apparatus

    DOEpatents

    Voronov, Oleg A.

    2005-09-13

    A design for high pressure/high temperature apparatus and reaction cell to achieve .about.30 GPa pressure in .about.1 cm volume and .about.100 GPa pressure in .about.1 mm volumes and 20-5000.degree. C. temperatures in a static regime. The device includes profiled anvils (28) action on a reaction cell (14, 16) containing the material (26) to be processed. The reaction cell includes a heater (18) surrounded by insulating layers and screens. Surrounding the anvils are cylindrical inserts and supporting rings (30-48) whose hardness increases towards the reaction cell. These volumes may be increased considerably if applications require it, making use of presses that have larger loading force capability, larger frames and using larger anvils.

  8. Altered Pituitary Gland Structure and Function in Posttraumatic Stress Disorder

    PubMed Central

    Bonert, Vivien; Moser, Franklin; Mirocha, James; Melmed, Shlomo

    2017-01-01

    Objectives: Posttraumatic stress disorder (PTSD) is associated with hypothalamus-pituitary-adrenal (HPA) axis response to stressors, but links to neurophysiological and neuroanatomical changes are unclear. The purpose of this study was to determine whether stress-induced cortisol alters negative feedback on pituitary corticotroph function and pituitary volume. Design: Prospective controlled study in an outpatient clinic. Methods: Subjects with PTSD and matched control subjects underwent pituitary volume measurement on magnetic resonance imaging, with pituitary function assessed by 24-hour urine free cortisol (UFC), 8:00 am cortisol, and adrenocorticotropic hormone (ACTH) levels, and ACTH levels after 2-day dexamethasone/corticotropin-releasing hormone test. Primary outcome was pituitary volume; secondary outcomes were ACTH area under the curve (AUC) and 24-hour UFC. Results: Thirty-nine subjects were screened and 10 subjects with PTSD were matched with 10 healthy control subjects by sex and age. Mean pituitary volume was 729.7 mm3 [standard deviation (SD), 227.3 mm3] in PTSD subjects vs 835.2 mm3 (SD, 302.8 mm3) in control subjects. ACTH AUC was 262.5 pg/mL (SD, 133.3 pg/mL) L in PTSD vs 244.0 pg/mL (SD, 158.3 pg/mL) in control subjects (P = 0.80). In PTSD subjects, UFC levels and pituitary volume inversely correlated with PTSD duration; pituitary volume correlated with ACTH AUC in control subjects (Pearson correlation coefficient, 0.88, P = 0.0009) but not in PTSD subjects. Conclusions: The HPA axis may be downregulated and dysregulated in people with PTSD, as demonstrated by discordant pituitary corticotroph function and pituitary volume vs intact HPA feedback and correlation of pituitary volume with ACTH levels in healthy control subjects. The results suggest a link between pituitary structure and function in PTSD, which may point to endocrine targeted therapeutic approaches. PMID:29264511

  9. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia.

    PubMed

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-09-01

    Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.

  10. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia

    PubMed Central

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-01-01

    Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661

  11. Rapid and sensitive screening and selective quantification of antibiotics in human urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, He-Xing; Wang, Bin; Zhou, Ying; Jiang, Qing-Wu

    2014-12-01

    A rapid and sensitive method for the screening and selective quantification of antibiotics in urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry was developed. This method allowed the injection of 200 μL urine extract. The 200-μL injection volume used in this method increased the absolute sensitivity for target antibiotics in solvent by an average 13.3 times, with a range from 8.4 to 28.5 times, compared with the 10-μL conventional injection volume. A 96-well solid phase extraction procedure was established to eliminate the contamination on the chromatographic column resulting from the large-volume injection and increase the throughput of sample preparation. Fourteen target antibiotics from six common categories (β-lactams, quinolones, tetracyclines, macrolides, sulfonamides, and chloramphenicols) were selected as model compounds, and a database containing an additional 74 antibiotics was compiled for posttarget screening. The limit of detection of the target antibiotics, defined as a signal-to-noise ratio of 3, ranged from 0.04 to 1.99 ng/mL. The mean interday recoveries ranged between 79.6 and 121.3 %, with a relative standard deviation from 2.9 to 18.3 % at three spiking levels of 20 ng/mL, 50 ng/mL, and 100 ng/mL. This method was successfully applied in 60 real urine samples from schoolchildren aged 8-11 years, and four target antibiotics (azithromycin, sulfadiazine, trimethoprim, and oxytetracycline) and two posttarget antibiotics (sulfadimidine and cefaclor) were found in the urine samples. This method can be used as a large-scale biomonitoring tool for exposure of the human population to antibiotics.

  12. Effect of Preoperative Mastoid Ventilation on Tympanoplasty Success

    PubMed Central

    Metin, Mehmet; Kaptan, Zeynep Kizilkaya; Dogan, Sedat; Yazici, Hasmet; Bayraktar, Cem; Gocmen, Hakan; Samim, Etem Erdal

    2014-01-01

    Purpose. This study was conducted with the aim of investigating the relationship between mastoid air cell volumes and graft success after tympanoplasty. Material and Methods. This study was performed retrospectively with patients undergoing type I tympanoplasty and antrostomy. A total of 57 patients (20–35.09% female and 37–64.91% male) with a mean age of 29.69 ± SD (range 12–56 years) were included in the study. The patients were invited for a control at the 1st, 3rd, and 12th months, and otoscopic examinations and audiometric tests were performed. The temporal bone computed tomography images were screened with the 4800 Dpi optic resolution scanner and transferred to the computer environment in JPG format in order to calculate the mastoid air cell volume, and the volumes were calculated using the Autocad 2007 program. Results. Although, the graft success was determined to be better in the well-ventilated group, no significant difference could be found between the groups in terms of graft success at the 1st, 3rd, and 12th months (P > 0.05). No statistically significant difference could be found between the three groups in terms of the preoperative and postoperative hearing gains (P > 0.05). PMID:25374605

  13. Review of the evidence on the use of arbitration or consensus within breast screening: A systematic scoping review.

    PubMed

    Hackney, L; Szczepura, A; Moody, L; Whiteman, B

    2017-05-01

    A systematic scoping review was undertaken to establish the evidence base on arbitration and consensus in mammography reporting. Database searches were supplemented with hand searching of peer-reviewed journals, citation tracking, key author searching, grey literature and personal contact with experts. A 3-stage process was utilised to screen a large volume of literature (601) against the inclusion and exclusion criteria. 26 papers were retained. A lack of guidance and underpinning evidence to inform how best to use arbitration or consensus to resolve discordant reads. In particular, a lack of prospective studies to determine effectiveness in real-life clinical settings. The insufficiency of follow-up or reporting of true interval cancers compromised the ability to conclude the effectiveness of the processes. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  14. Simulation of breast compression in mammography using finite element analysis: A preliminary study

    NASA Astrophysics Data System (ADS)

    Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay

    2017-11-01

    Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.

  15. Quantifying Golgi structure using EM: combining volume-SEM and stereology for higher throughput.

    PubMed

    Ferguson, Sophie; Steyer, Anna M; Mayhew, Terry M; Schwab, Yannick; Lucocq, John Milton

    2017-06-01

    Investigating organelles such as the Golgi complex depends increasingly on high-throughput quantitative morphological analyses from multiple experimental or genetic conditions. Light microscopy (LM) has been an effective tool for screening but fails to reveal fine details of Golgi structures such as vesicles, tubules and cisternae. Electron microscopy (EM) has sufficient resolution but traditional transmission EM (TEM) methods are slow and inefficient. Newer volume scanning EM (volume-SEM) methods now have the potential to speed up 3D analysis by automated sectioning and imaging. However, they produce large arrays of sections and/or images, which require labour-intensive 3D reconstruction for quantitation on limited cell numbers. Here, we show that the information storage, digital waste and workload involved in using volume-SEM can be reduced substantially using sampling-based stereology. Using the Golgi as an example, we describe how Golgi populations can be sensed quantitatively using single random slices and how accurate quantitative structural data on Golgi organelles of individual cells can be obtained using only 5-10 sections/images taken from a volume-SEM series (thereby sensing population parameters and cell-cell variability). The approach will be useful in techniques such as correlative LM and EM (CLEM) where small samples of cells are treated and where there may be variable responses. For Golgi study, we outline a series of stereological estimators that are suited to these analyses and suggest workflows, which have the potential to enhance the speed and relevance of data acquisition in volume-SEM.

  16. Race differences in ventricular remodeling and function among college football players.

    PubMed

    Haddad, Francois; Peter, Shanon; Hulme, Olivia; Liang, David; Schnittger, Ingela; Puryear, Josephine; Gomari, Fatemeh A; Finocchiaro, Gherardo; Myers, Jonathan; Froelicher, Victor; Garza, Daniel; Ashley, Euan A

    2013-07-01

    Athletic training is associated with increases in ventricular mass and volume. Recent studies have shown that left ventricular mass increases proportionally in white athletes with a mass/volume ratio approaching unity. The objective of this study was to compare the proportionality in ventricular remodeling and ventricular function in black versus white National Collegiate Athletic Association Division I football players. From 2008 to 2011, football players at Stanford University underwent cardiovascular screening with a 12-point history and physical examination, electrocardiography, and focused echocardiography. Compared with white players, black players had on average higher left ventricular mass indexes (77 ± 11 vs 71 ± 11 g/m(2), p = 0.009), higher mass/volume ratios (1.18 ± 0.16 vs 1.06 ± 0.09 g/ml, p <0.001), and higher QRS vector magnitudes (3.2 ± 0.7 vs 2.7 ± 0.8, p = 0.002). Black race had an odds ratio of 14 (95% confidence interval 5 to 42, p <0.001) for a mass/volume ratio >1.2. Mass/volume ratio was inversely related to early diastolic tissue Doppler velocity e' (r = -0.50, p <0.001) but not to QRS vector magnitude (r = 0.065, p = 0.034). With regard to systolic indexes, there was no significant difference in the left ventricular ejection fraction, velocity of circumferential shortening, and isovolumic acceleration. In conclusion, black college football players exhibit more concentric ventricular remodeling, lower early diastolic annular velocities, and increased ventricular voltage compared with white players. Ventricular mass increases proportionally to volume in white players but not in black players. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Sleep quality is negatively related to video gaming volume in adults.

    PubMed

    Exelmans, Liese; Van den Bulck, Jan

    2015-04-01

    Most literature on the relationship between video gaming and sleep disturbances has looked at children and adolescents. There is little research on such a relationship in adult samples. The aim of the current study was to investigate the association of video game volume with sleep quality in adults via face-to-face interviews using standardized questionnaires. Adults (n = 844, 56.2% women), aged 18-94 years old, participated in the study. Sleep quality was measured using the Pittsburgh Sleep Quality Index, and gaming volume was assessed by asking the hours of gaming on a regular weekday (Mon-Thurs), Friday and weekend day (Sat-Sun). Adjusting for gender, age, educational level, exercise and perceived stress, results of hierarchical regression analyses indicated that video gaming volume was a significant predictor of sleep quality (β = 0.145), fatigue (β = 0.109), insomnia (β = 0.120), bedtime (β = 0.100) and rise time (β = 0.168). Each additional hour of video gaming per day delayed bedtime by 6.9 min (95% confidence interval 2.0-11.9 min) and rise time by 13.8 min (95% confidence interval 7.8-19.7 min). Attributable risk for having poor sleep quality (Pittsburgh Sleep Quality Index > 5) due to gaming >1 h day was 30%. When examining the components of the Pittsburgh Sleep Quality Index using multinomial regression analysis (odds ratios with 95% confidence intervals), gaming volume significantly predicted sleep latency, sleep efficiency and use of sleep medication. In general, findings support the conclusion that gaming volume is negatively related to the overall sleep quality of adults, which might be due to underlying mechanisms of screen exposure and arousal. © 2014 European Sleep Research Society.

  18. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  19. Vinken and Bruyn's Handbook of Clinical Neurology. A witness of late-twentieth century neurological progress.

    PubMed

    Koehler, P J; Jennekens, F G I

    2008-01-01

    Vinken and Bruyn's Handbook of Clinical Neurology (HCN) is best characterized as an encyclopedia. In this paper we describe the origin, production, and reception of HCN. Data were gathered from a literature search, by screening of HCN-volumes, interviewing key-role persons and a study of an HCN-archive. The initiative for HCN was taken by two Excerpta Medica staff members, the one a strategist with expertise in information systems, the other a gifted neurologist with an expert knowledge of who is who in the world of neurological literature. Within a period of 38 years, 2799 authors, 28 volume editors, the two initiators, and a third chief editor for the American continent described the whole of neurology in 1909 chapters on all together 46,025 pages (excluding index volumes). HCN was sold mainly to medical institutes in affluent countries. A digital version of the revised edition was proposed by the editors but refused by the publisher for commercial reasons. HCN was in general well received by book reviewers. The main criticisms concerned the price of the volumes, lack of editorial control, inadequacy of indexes, and lack of cross references. HCN offers unrivalled information on the state of the art of the clinical neurosciences in the second half of the twentieth century. In addition, it contains extensive reviews of the history of neurological diseases in the volumes of the original edition.

  20. Combining partially ranked data in plant breeding and biology: II. Analysis with Rasch model.

    USDA-ARS?s Scientific Manuscript database

    Many years of breeding experiments, germplasm screening, and molecular biologic experimentation have generated volumes of sequence, genotype, and phenotype information that have been stored in public data repositories. These resources afford genetic and genomic researchers the opportunity to handle ...

  1. Ultra-low altitude and low spraying technology research with UAV in paddy

    USDA-ARS?s Scientific Manuscript database

    Aerial application has characteristics of low-volume, small droplet, and possibility of drift. To control rice planthopper, leaf roller and blast, the research aimed at screening agrichemicals and determining the feasibility of using high concentration of conventional dosage for aerial application....

  2. Scanning of vehicles for nuclear materials

    NASA Astrophysics Data System (ADS)

    Katz, J. I.

    2014-05-01

    Might a nuclear-armed terrorist group or state use ordinary commerce to deliver a nuclear weapon by smuggling it in a cargo container or vehicle? This delivery method would be the only one available to a sub-state actor, and it might enable a state to make an unattributed attack. Detection of a weapon or fissile material smuggled in this manner is difficult because of the large volume and mass available for shielding. Here I review methods for screening cargo containers to detect the possible presence of nuclear threats. Because of the large volume of innocent international commerce, and the cost and disruption of secondary screening by opening and inspection, it is essential that the method be rapid and have a low false-positive rate. Shielding can prevent the detection of neutrons emitted spontaneously or by induced fission. The two promising methods are muon tomography and high energy X-radiography. If they do not detect a shielded threat object they can detect the shield itself.

  3. Scanning of vehicles for nuclear materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katz, J. I.

    2014-05-09

    Might a nuclear-armed terrorist group or state use ordinary commerce to deliver a nuclear weapon by smuggling it in a cargo container or vehicle? This delivery method would be the only one available to a sub-state actor, and it might enable a state to make an unattributed attack. Detection of a weapon or fissile material smuggled in this manner is difficult because of the large volume and mass available for shielding. Here I review methods for screening cargo containers to detect the possible presence of nuclear threats. Because of the large volume of innocent international commerce, and the cost andmore » disruption of secondary screening by opening and inspection, it is essential that the method be rapid and have a low false-positive rate. Shielding can prevent the detection of neutrons emitted spontaneously or by induced fission. The two promising methods are muon tomography and high energy X-radiography. If they do not detect a shielded threat object they can detect the shield itself.« less

  4. Water Membrane Evaporator

    NASA Technical Reports Server (NTRS)

    Ungar, Eugene K.; Almlie, Jay C.

    2010-01-01

    A water membrane evaporator (WME) has been conceived and tested as an alternative to the contamination-sensitive and corrosion-prone evaporators currently used for dissipating heat from space vehicles. The WME consists mainly of the following components: An outer stainless-steel screen that provides structural support for the components mentioned next; Inside and in contact with the stainless-steel screen, a hydrophobic membrane that is permeable to water vapor; Inside and in contact with the hydrophobic membrane, a hydrophilic membrane that transports the liquid feedwater to the inner surface of the hydrophobic membrane; Inside and in contact with the hydrophilic membrane, an annular array of tubes through which flows the spacecraft coolant carrying the heat to be dissipated; and An inner exclusion tube that limits the volume of feedwater in the WME. In operation, a pressurized feedwater reservoir is connected to the volume between the exclusion tube and the coolant tubes. Feedwater fills the volume, saturates the hydrophilic membrane, and is retained by the hydrophobic membrane. The outside of the WME is exposed to space vacuum. Heat from the spacecraft coolant is conducted through the tube walls and the water-saturated hydrophilic membrane to the liquid/vapor interface at the hydrophobic membrane, causing water to evaporate to space. Makeup water flows into the hydrophilic membrane through gaps between the coolant tubes.

  5. Cervical cancer screening, human papillomavirus vaccination practices and current infrastructure in Israel.

    PubMed

    Schejter, Eduardo; Bornstein, Jacob; Siegler, Efraim

    2013-11-22

    The incidence rates for premalignant lesions in Jewish women in Israel are similar to those observed in Western countries, but the incidence of cervical cancer in Israel is low; this discrepancy is not yet clearly understood. Because of the low incidence of cervical cancer in Israel, it was decided to base cervical cancer prevention on opportunistic screening: every woman from the ages of 35-54 years can have a Pap test smear free of charge every 3 years. Over the last decade 12.2% of the women population had an annual Pap test. From 36 to 50% of women who attended the Clalit Health Maintenance Organization (HMO) and the Maccabi HMO, the two largest HMOs in Israel, did so. There were also discrepancies between women of different socio-economic status (SES): <10% in the lowest SES level were screened compared to almost 55% in the higher level. HPV vaccination was opportunistic but it will be introduced to the school-based vaccine program at age of 13 years old as of September 2013. The Israel Society of Obstetrics and Gynecology recommends continuing cytologic screening in vaccinated women as recommended for the general population. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in Israel" Vaccine Volume 31, Supplement 8, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2013. Published by Elsevier Ltd.

  6. Mission definition study for Stanford relativity satellite. Volume 3: Appendices

    NASA Technical Reports Server (NTRS)

    1971-01-01

    An analysis is presented for the cost of the mission as a function of the following variables: amount of redundancy in the spacecraft, amount of care taken in building the spacecraft (functional and environmental tests, screening of components, quality control, etc), and the number of flights necessary to accomplish the mission. Thermal analysis and mathematical models for the experimental components are presented. The results of computer structural and stress analyses for support and cylinders are discussed. Reliability, quality control, and control system simulation by computer are also considered.

  7. Influence of pressure and volume on superconductivity in Mg1-xAlxB2 and Mg(B1-yCy)2

    NASA Astrophysics Data System (ADS)

    Sharma, Roopam; Singh, Namita; Khenata, R.; Varshney, Dinesh

    2018-05-01

    A quantitative analysis of observed parameters is studied that influences superconducting state in Al (C) doped MgB2. The three square well model with three interactions namely, the Coulomb the electron-phonon and the electron- charge fluctuations is based on indirect-exchange Cooper pairing of electrons (quasiparticles) via adhoc attractive charge fluctuations apart from phonons. The relevant energy gap expressions are solved. The indirect-exchange formalism provides a unique set of electronic parameters [electron-phonon (λσσph), electron-charge fluctuations (λσσpl), electron-electron (μσσ) and Coulomb screening parameter (μσσ*)] which, in particular, reproduce the dependence of Tc on Al (C) doping concentration and pressure P. Also, the variation in slope dTc/dP with increased Al (C) substitution (0 ≤ x ≤ 0.5)(0 ≤ y ≤ 0.125) is studied. Moreover, variation of dlnTc/dV Å-3 as a function of electron-phonon coupling strength and as a function of Coulomb screening parameter is studied.

  8. Differential longitudinal changes in cortical thickness, surface area and volume across the adult life span: regions of accelerating and decelerating change.

    PubMed

    Storsve, Andreas B; Fjell, Anders M; Tamnes, Christian K; Westlye, Lars T; Overbye, Knut; Aasland, Hilde W; Walhovd, Kristine B

    2014-06-18

    Human cortical thickness and surface area are genetically independent, emerge through different neurobiological events during development, and are sensitive to different clinical conditions. However, the relationship between changes in the two over time is unknown. Additionally, longitudinal studies have almost invariably been restricted to older adults, precluding the delineation of adult life span trajectories of change in cortical structure. In this longitudinal study, we investigated changes in cortical thickness, surface area, and volume after an average interval of 3.6 years in 207 well screened healthy adults aged 23-87 years. We hypothesized that the relationships among metrics are dynamic across the life span, that the primary contributor to cortical volume reductions in aging is cortical thinning, and that magnitude of change varies with age and region. Changes over time were seen in cortical area (mean annual percentage change [APC], -0.19), thickness (APC, -0.35), and volume (APC, -0.51) in most regions. Volume changes were primarily explained by changes in thickness rather than area. A negative relationship between change in thickness and surface area was found across several regions, where more thinning was associated with less decrease in area, and vice versa. Accelerating changes with increasing age was seen in temporal and occipital cortices. In contrast, decelerating changes were seen in prefrontal and anterior cingulate cortices. In conclusion, a dynamic relationship between cortical thickness and surface area changes exists throughout the adult life span. The mixture of accelerating and decelerating changes further demonstrates the importance of studying these metrics across the entire adult life span. Copyright © 2014 the authors 0270-6474/14/348488-11$15.00/0.

  9. Relationships between sleep quality and brain volume, metabolism, and amyloid deposition in late adulthood.

    PubMed

    Branger, Pierre; Arenaza-Urquijo, Eider M; Tomadesso, Clémence; Mézenge, Florence; André, Claire; de Flores, Robin; Mutlu, Justine; de La Sayette, Vincent; Eustache, Francis; Chételat, Gaël; Rauchs, Géraldine

    2016-05-01

    Recent studies in mouse models of Alzheimer's disease (AD) and in humans suggest that sleep disruption and amyloid-beta (Aβ) accumulation are interrelated, and may, thus, exacerbate each other. We investigated the association between self-reported sleep variables and neuroimaging data in 51 healthy older adults. Participants completed a questionnaire assessing sleep quality and quantity and underwent positron emission tomography scans using [18F]florbetapir and [18F]fluorodeoxyglucose and an magnetic resonance imaging scan to measure Aβ burden, hypometabolism, and atrophy, respectively. Longer sleep latency was associated with greater Aβ burden in prefrontal areas. Moreover, the number of nocturnal awakenings was negatively correlated with gray matter volume in the insular region. In asymptomatic middle-aged and older adults, lower self-reported sleep quality was associated with greater Aβ burden and lower volume in brain areas relevant in aging and AD, but not with glucose metabolism. These results highlight the potential relevance of preserving sleep quality in older adults and suggest that sleep may be a factor to screen for in individuals at risk for AD. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Tracking of the micro-structural changes of levonorgestrel-releasing intrauterine system by positron annihilation lifetime spectroscopy.

    PubMed

    Patai, Kálmán; Szente, Virág; Süvegh, Károly; Zelkó, Romána

    2010-12-01

    The morphology and the micro-structural changes of levonorgestrel-releasing intrauterine systems (IUSs) were studied in relation to the duration of their application. The morphology of the removed IUSs was examined without pre-treatment by scanning electron microscopy. The micro-structural changes of the different layers of IUSs were tracked by positron annihilation lifetime spectroscopy. Besides the previously found incrustation formation, the free volume of the hormone containing reservoir was remarkably increased after 3 years of application, thus increasing the real volume of the core of the systems. Although the free volume of the membrane encasing the core was not significantly changed in the course of the application, as a result of the core expansion, microcracks could be formed on the membrane surface. Along these cracks, deposits of different compositions can be formed, causing inflammatory complications and influencing the drug release of IUSs. Stability tests in combination with micro-structural screening of such IUSs could be required during their development phase to avoid the undesired side effects. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Acoustic Droplet Ejection Technology and Its Application in High-Throughput RNA Interference Screening.

    PubMed

    Nebane, N Miranda; Coric, Tatjana; McKellip, Sara; Woods, LaKeisha; Sosa, Melinda; Rasmussen, Lynn; Bjornsti, Mary-Ann; White, E Lucile

    2016-02-01

    The development of acoustic droplet ejection (ADE) technology has resulted in many positive changes associated with the operations in a high-throughput screening (HTS) laboratory. Originally, this liquid transfer technology was used to simply transfer DMSO solutions of primarily compounds. With the introduction of Labcyte's Echo 555, which has aqueous dispense capability, the application of this technology has been expanded beyond its original use. This includes the transfer of many biological reagents solubilized in aqueous buffers, including siRNAs. The Echo 555 is ideal for siRNA dispensing because it is accurate at low volumes and a step-down dilution is not necessary. The potential for liquid carryover and cross-contamination is eliminated, as no tips are needed. Herein, we describe the siRNA screening platform at Southern Research's HTS Center using the ADE technology. With this technology, an siRNA library can be dispensed weeks or even months in advance of the assay itself. The protocol has been optimized to achieve assay parameters comparable to small-molecule screening parameters, and exceeding the norm reported for genomewide siRNA screens. © 2015 Society for Laboratory Automation and Screening.

  12. Validation Analysis of a Geriatric Dehydration Screening Tool in Community-Dwelling and Institutionalized Elderly People

    PubMed Central

    Rodrigues, Susana; Silva, Joana; Severo, Milton; Inácio, Cátia; Padrão, Patrícia; Lopes, Carla; Carvalho, Joana; do Carmo, Isabel; Moreira, Pedro

    2015-01-01

    Dehydration is common among elderly people. The aim of this study was to perform validation analysis of a geriatric dehydration-screening tool (DST) in the assessment of hydration status in elderly people. This tool was based on the DST proposed by Vivanti et al., which is composed by 11 items (four physical signs of dehydration and seven questions about thirst sensation, pain and mobility), with four questions extra about drinking habits. The resulting questionnaire was evaluated in a convenience sample comprising institutionalized (n = 29) and community-dwelling (n = 74) elderly people. Urinary parameters were assessed (24-h urine osmolality and volume) and free water reserve (FWR) was calculated. Exploratory factor analysis was used to evaluate the scale’s dimensionality and Cronbach’s alpha was used to measure the reliability of each subscale. Construct’s validity was tested using linear regression to estimate the association between scores in each dimension and urinary parameters. Two factors emerged from factor analysis, which were named “Hydration Score” and “Pain Score”, and both subscales showed acceptable reliabilities. The “Hydration Score” was negatively associated with 24-h urine osmolality in community-dwelling; and the “Pain Score” was negatively associated with 24-h urine osmolality, and positively associated with 24-h urine volume and FWR in institutionalized elderly people. PMID:25739005

  13. Dynamic CT imaging of volumetric changes in pulmonary nodules correlates with physical measurements of stiffness.

    PubMed

    Lartey, Frederick M; Rafat, Marjan; Negahdar, Mohammadreza; Malkovskiy, Andrey V; Dong, Xinzhe; Sun, Xiaoli; Li, Mei; Doyle, Timothy; Rajadas, Jayakumar; Graves, Edward E; Loo, Billy W; Maxim, Peter G

    2017-02-01

    A major challenge in CT screening for lung cancer is limited specificity when distinguishing between malignant and non-malignant pulmonary nodules (PN). Malignant nodules have different mechanical properties and tissue characteristics ('stiffness') from non-malignant nodules. This study seeks to improve CT specificity by demonstrating in rats that measurements of volumetric ratios in PNs with varying composition can be determined by respiratory-gated dynamic CT imaging and that these ratios correlate with direct physical measurements of PN stiffness. Respiratory-gated MicroCT images acquired at extreme tidal volumes of 9 rats with PNs from talc, matrigel and A549 human lung carcinoma were analyzed and their volumetric ratios (δ) derived. PN stiffness was determined by measuring the Young's modulus using atomic force microscopy (AFM) for each nodule excised immediately after MicroCT imaging. There was significant correlation (p=0.0002) between PN volumetric ratios determined by respiratory-gated CT imaging and the physical stiffness of the PNs determined from AFM measurements. We demonstrated proof of concept that PN volume changes measured non-invasively correlate with direct physical measurements of stiffness. These results may translate clinically into a means of improving the specificity of CT screening for lung cancer and/or improving individual prognostic assessments based on lung tumor stiffness. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    PubMed

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Characterization of helium diffusion behavior from continuous heating experiments: Sample screening and identification of multiple 4He components

    NASA Astrophysics Data System (ADS)

    McDannell, K. T.; Idleman, B. D.; Zeitler, P. K.

    2015-12-01

    Old, slowly cooled apatites often yield overdispersed helium ages due to factors such as parent zonation, He implantation, radiation damage, crystal defects, and fluid inclusions. Careful mineral selection and many replicate analyses can mitigate the impact of some of these effects. However, this approach adds unnecessary costs in time and resources when dating well-behaved apatites and is generally ineffective at identifying the root cause of age dispersion and providing suitable age corrections for poorly behaved samples. We assess a new technique utilizing static-gas measurement during continuous heating as a means to rapidly screen apatite samples. In about the time required for a conventional total-gas analysis, this method can discriminate between samples showing the volume-diffusion behavior expected for apatite and those showing anomalous release patterns, inconsistent with their use in thermochronologic applications. This method may also have the potential to quantify and discriminate between the radiogenic and extraneous 4He fractions released by a sample. Continuously heated samples that outgas by volume diffusion during a linear heating schedule should produce a characteristic sigmoidal 4He fractional loss profile, with the exact shape and position of these profiles (in loss vs. heating time space) controlled by sample kinetics, grain size, and heating rate. Secondary factors such as sample zoning and alpha-loss distribution have a relatively minor impact on such profiles. Well-behaved examples such as the Durango standard and other apatites with good age reproducibility show the expected smooth, sigmoidal gas release with complete exhaustion by temperatures predicted for volume diffusion using typical apatite kinetics (e.g., by ~900˚C for linear heating at 20˚C/minute). In contrast, "bad actor" samples that do not replicate well show significant degrees of helium release deferred to higher temperatures. We report on screening results for a range of samples including a suite of slowly cooled Cretaceous apatites from the Hangay Dome in central Mongolia, assessing the degree to which screening using cumulative heating can reliably identify bad-actor grains, and possibly, correct their ages.

  16. Efficient screening method for determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particles. Application in real samples of Santiago-Chile metropolitan urban area

    NASA Astrophysics Data System (ADS)

    Romero, Rodrigo; Sienra, Rosario; Richter, Pablo

    A rapid analytical approach for determination of polycyclic aromatic hydrocarbons (PAHs) present in real samples of particulate matter (PM10 filters) was investigated, based on the use of water under sub critical conditions, and the subsequent determination by GC-MS (SIM). The method avoids the use of large volumes of organic solvents as dichloromethane, toluene or other unhealthy liquid organic mixtures which are normally used in time-consuming conventional sample preparation methods. By using leaching times <1 h, the method allows determination of PAHs in the range of ng/m 3 (detection limits between 0.05 and 0.2 ng/m 3 for 1458 m 3 of sampled air) with a precision expressed as RSD between 5.6% and 11.2%. The main idea behind this approach is to raise the temperature and pressure of water inside a miniaturized laboratory-made extraction unit and to decrease its dielectric constant from 80 to nearly 20. This effect allows an increase in the solubility of low polarity hydrocarbons such as PAHs. In this way, an extraction step of a few minutes can be sufficient for a quantitative extraction of airborne particles collected in high volume PM10 samplers. Parameters such as: extraction flow, static or dynamic extraction times and water volume were optimized by using a standard reference material. Technical details are given and a comparison using real samples is made between the conventional Soxhlet extraction method and the proposed approach. The proposed approach can be used as a quantitative method to characterize low molecular PAHs and simultaneously as a screening method for high molecular weight PAHs, because the recoveries are not quantitative for molecular weights over 202. In the specific case of the Santiago metropolitan area, due to the frequent occurrence of particulate matter during high pollution episodes, this approach was applied as an efficient short-time screening method for urban PAHs. Application of this screening method is recommended especially during the winter, when periods of clear detriment of the atmospheric and meteorological conditions occur in the area.

  17. NASA Conjunction Assessment Organizational Approach and the Associated Determination of Screening Volume Sizes

    NASA Technical Reports Server (NTRS)

    Newman, Lauri K.; Hejduk, Matthew D.

    2015-01-01

    NASA is committed to safety of flight for all of its operational assets Performed by CARA at NASA GSFC for robotic satellites Focus of this briefing Performed by TOPO at NASA JSC for human spaceflight he Conjunction Assessment Risk Analysis (CARA) was stood up to offer this service to all NASA robotic satellites Currently provides service to 70 operational satellites NASA unmanned operational assets Other USG assets (USGS, USAF, NOAA) International partner assets Conjunction Assessment (CA) is the process of identifying close approaches between two orbiting objects; sometimes called conjunction screening The Joint Space Operations Center (JSpOC) a USAF unit at Vandenberg AFB, maintains the high accuracy catalog of space objects, screens CARA-supported assets against the catalog, performs OD tasking, and generates close approach data.

  18. NE-TWIGS update: Incorporating tree quality

    Treesearch

    Daniel A. Yaussy

    1993-01-01

    A method to distribute tree quality was incorporated into the NE-TWIGS individual-tree growth and yield simulator. The program uses potential tree grade to allow changes in actual tree grade over time. Volume is reported by grade and value is calculated using tree grades. Example screens are shown.

  19. Tier 1 Rice Model for Estimating Pesticide Concentrations in Rice Paddies

    EPA Science Inventory

    The Tier 1 Rice Model estimates screening level aquatic concentrations of pesticides in rice paddies. It is a simple pesticide soil:water partitioning model with default values for water volume, soil mass, and organic carbon. Pesticide degradation is not considered in the mode...

  20. GPS/IGS Design Analysis Report. Volume 1

    DTIC Science & Technology

    1982-11-15

    PLL Phase Lock Loop FMPCB Parts, Hateriala, and Processes Control Board PPPL Program Preferred Parts List P14 Pseudo-Rando* Noise PSI Peculiar Support...program preferred ?arts list ( PPPL ). Where ?PPL parts were not obtainable, screening, burn-in, and other tes. were imposed on those parts to assure

  1. Integrated economic and experimental framework for screening of primary recovery technologies for high cell density CHO cultures

    PubMed Central

    Popova, Daria; Stonier, Adam; Pain, David; Titchener‐Hooker, Nigel J.

    2016-01-01

    Abstract Increases in mammalian cell culture titres and densities have placed significant demands on primary recovery operation performance. This article presents a methodology which aims to screen rapidly and evaluate primary recovery technologies for their scope for technically feasible and cost‐effective operation in the context of high cell density mammalian cell cultures. It was applied to assess the performance of current (centrifugation and depth filtration options) and alternative (tangential flow filtration (TFF)) primary recovery strategies. Cell culture test materials (CCTM) were generated to simulate the most demanding cell culture conditions selected as a screening challenge for the technologies. The performance of these technology options was assessed using lab scale and ultra scale‐down (USD) mimics requiring 25–110mL volumes for centrifugation and depth filtration and TFF screening experiments respectively. A centrifugation and depth filtration combination as well as both of the alternative technologies met the performance selection criteria. A detailed process economics evaluation was carried out at three scales of manufacturing (2,000L, 10,000L, 20,000L), where alternative primary recovery options were shown to potentially provide a more cost‐effective primary recovery process in the future. This assessment process and the study results can aid technology selection to identify the most effective option for a specific scenario. PMID:27067803

  2. The utility of Google Trends data to examine interest in cancer screening

    PubMed Central

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-01-01

    Objectives We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. Setting State-level data across the USA. Participants Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). Primary and secondary outcome measures (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Results Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Conclusions Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. PMID:26056120

  3. Respiratory health screening for opiate misusers in a specialist community clinic: a mixed-methods pilot study, with integrated staff and service user feedback

    PubMed Central

    Mitchell, Caroline Anne; Pitt, Alice; Hulin, Joe; Lawson, Rod; Ashby, Fleur; Appelqvist, Ivan; Delaney, Brigitte

    2016-01-01

    Objectives Increased rates of illicit drug inhalation are thought to expose opiate misusers (OMUs) to an enhanced risk of respiratory health problems. This pilot study aimed to determine the feasibility of undertaking respiratory screening of OMUs in a community clinic. Setting Single-centre UK community substance misuse clinic. Participants All clinic attendees receiving treatment for opiate misuse were eligible to participate. 36 participants (mean age=37) were recruited over a 5-week period. The sample included 26 males and 10 females. Outcome measures Spirometry without bronchodilation; health related quality of life EQ-5D-3L; Asthma Control Test; Mini Asthma Quality of Life; Clinical COPD Questionnaire and the Treatment Outcome Profile were used to assess the respiratory health of participants. Findings were discussed with staff and service users in 2 patient and public involvement events and feedback was analysed thematically. Results 34 participants reported that they had smoked heroin. 8 participants diagnosed with asthma, scored under 13 on the Asthma Control Test, suggesting poorly controlled asthma. Participants (n=28), without a diagnosis of asthma completed the Lung Function Questionnaire. Of these, 79% produced scores under 18, indicating symptoms associated with the development of chronic obstructive pulmonary disease. Spirometry showed 14% of all participants had forced expiratory volume in 1 s/forced vital capacity <0.7 (without bronchodilator), indicating potential obstructive lung disease. Feedback from service users and staff suggested a willingness and capacity to deliver respiratory health screening programmes. Insight towards the difficulties service users have in accessing services and the burden of respiratory health was also provided. Conclusions It is feasible to undertake respiratory health screening of OMUs in a community clinic. Larger screening studies are warranted to determine the prevalence of respiratory health problems in this population. Research regarding asthma medicines adherence and access to healthcare among OMUs is also required. PMID:27742632

  4. "Inject-mix-react-separate-and-quantitate" (IMReSQ) method for screening enzyme inhibitors.

    PubMed

    Wong, Edmund; Okhonin, Victor; Berezovski, Maxim V; Nozaki, Tomoyoshi; Waldmann, Herbert; Alexandrov, Kirill; Krylov, Sergey N

    2008-09-10

    Many regulatory enzymes are considered attractive therapeutic targets, and their inhibitors are potential drug candidates. Screening combinatorial libraries for enzyme inhibitors is pivotal to identifying hit compounds for the development of drugs targeting regulatory enzymes. Here, we introduce the first inhibitor screening method that consumes only nanoliters of the reactant solutions and is applicable to regulatory enzymes. The method is termed inject-mix-react-separate-and-quantitate (IMReSQ) and includes five steps. First, nanoliter volumes of substrate, candidate inhibitor, and enzyme solutions are injected by pressure into a capillary as separate plugs. Second, the plugs are mixed inside this capillary microreactor by transverse diffusion of laminar flow profiles. Third, the reaction mixture is incubated to form the enzymatic product. Fourth, the product is separated from the substrate inside the capillary by electrophoresis. Fifth, the amounts of the product and substrate are quantitated. In this proof-of-principle work, we applied IMReSQ to study inhibition of recently cloned protein farnesyltransferase from parasite Entamoeba histolytica. This enzyme is a potential therapeutic target for antiparasitic drugs. We identified three previously unknown inhibitors of this enzyme and proved that IMReSQ could be used for quantitatively ranking the potencies of inhibitors.

  5. Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking.

    PubMed

    Choi, Eun-Hye; Lee, Sang Kwang; Ihm, Chunhwa; Sohn, Young-Hak

    2014-12-01

    Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. The purpose of this study was to compare the quality, purity, and quantity of DNA isolated from frozen blood samples and DBSs. We optimized a method for extraction and estimation of DNA from blood spots dried on filter paper (3-mm FTA card). A single DBS containing 40 μL blood was used. DNA was efficiently extracted in phosphate-buffered saline (PBS) or Tris-EDTA (TE) buffer by incubation at 37°C overnight. DNA was stable in DBSs that were stored at room temperature or frozen. The housekeeping genes GAPDH and beta-actin were used as positive standards for polymerase chain reaction (PCR) validation of general diagnostic screening. Our simple and convenient DBS storage and extraction methods are suitable for diagnostic screening by using very small volumes of blood collected on filter paper, and can be used in biobanks for blood sample storage.

  6. Design and implementation of a controlled clinical trial to evaluate the effectiveness and efficiency of routine opt-out rapid human immunodeficiency virus screening in the emergency department.

    PubMed

    Haukoos, Jason S; Hopkins, Emily; Byyny, Richard L; Conroy, Amy A; Silverman, Morgan; Eisert, Sheri; Thrun, Mark; Wilson, Michael; Boyett, Brian; Heffelfinger, James D

    2009-08-01

    In 2006, the Centers for Disease Control and Prevention (CDC) released revised recommendations for performing human immunodeficiency virus (HIV) testing in health care settings, including implementing routine rapid HIV screening, the use of an integrated opt-out consent, and limited prevention counseling. Emergency departments (EDs) have been a primary focus of these efforts. These revised CDC recommendations were primarily based on feasibility studies and have not been evaluated through the application of rigorous research methods. This article describes the design and implementation of a large prospective controlled clinical trial to evaluate the CDC's recommendations in an ED setting. From April 15, 2007, through April 15, 2009, a prospective quasi-experimental equivalent time-samples clinical trial was performed to compare the clinical effectiveness and efficiency of routine (nontargeted) opt-out rapid HIV screening (intervention) to physician-directed diagnostic rapid HIV testing (control) in a high-volume urban ED. In addition, three nested observational studies were performed to evaluate the cost-effectiveness and patient and staff acceptance of the two rapid HIV testing methods. This article describes the rationale, methodologies, and study design features of this program evaluation clinical trial. It also provides details regarding the integration of the principal clinical trial and its nested observational studies. Such ED-based trials are rare, but serve to provide valid comparisons between testing approaches. Investigators should consider similar methodology when performing future ED-based health services research.

  7. Study of Permanent Magnet Focusing for Astronomical Camera Tubes

    NASA Technical Reports Server (NTRS)

    Long, D. C.; Lowrance, J. L.

    1975-01-01

    A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

  8. Federal Logistics Information Systems. FLIS Procedures Manual. Document Identifier Code Input/Output Formats (Variable Length). Volume 9.

    DTIC Science & Technology

    1997-04-01

    DATA COLLABORATORS 0001N B NQ 8380 NUMBER OF DATA RECEIVERS 0001N B NQ 2533 AUTHORIZED ITEM IDENTIFICATION DATA COLLABORATOR CODE 0002 ,X B 03 18 TD...01 NC 8268 DATA ELEMENT TERMINATOR CODE 000iX VT 9505 TYPE OF SCREENING CODE 0001A 01 NC 8268 DATA ELEMENT TERMINATOR CODE 000iX VT 4690 OUTPUT DATA... 9505 TYPE OF SCREENING CODE 0001A 2 89 2910 REFERENCE NUMBER CATEGORY CODE (RNCC) 0001X 2 89 4780 REFERENCE NUMBER VARIATION CODE (RNVC) 0001 N 2 89

  9. A Functional Assay for GPR55: Envision Protocol.

    PubMed

    Anavi-Goffer, Sharon; Ross, Ruth A

    2016-01-01

    AlphaScreen(®) SureFire(®) assay is a novel technology that combines luminescent oxygen channeling technology, nano-beads, and monocloncal antibodies to detect the level of a selected protein in a volume lower than 5 μl. This method is more sensitive compared with the traditional enzyme-linked immunosorbent assays (ELISA), and can detect an increasing number of new targets. Here, we described a method for AlphaScreen(®) SureFire(®) assay that targets ERK1/2 phosphorylation, a primary downstream signaling pathway that conveys activation of GPR55 by L-α-lysophosphatidylinositol (LPI) and certain cannabinoids.

  10. Chiasmus

    NASA Astrophysics Data System (ADS)

    Cady, Stephen

    2009-02-01

    Chiasmus is a responsive and dynamically reflective, two-sided volumetric surface that embodies phenomenological issues such as the formation of images, observer and machine perception and the dynamics of the screen as a space of image reception. It consists of a square grid of 64 individually motorized cube elements engineered to move linearly. Each cube is controlled by custom software that analyzes video imagery for luminance values and sends these values to the motor control mechanisms to coordinate the individual movements. The resolution of the sculptural screen from the individual movements allows its volume to dynamically alter, providing novel and unique perspectives of its mobile form to an observer.

  11. Sex Moderates the Impact of Diagnosis and Amyloid PET Positivity on Hippocampal Subfield Volume.

    PubMed

    Caldwell, Jessica Z K; Berg, Jody-Lynn; Shan, Guogen; Cummings, Jeffrey L; Banks, Sarah J

    2018-01-01

    We examined moderation effects of sex and diagnosis on the effect of positive florbetapir positron emission tomography (PET) amyloid-β (Aβ) scan (A+) on hippocampus subfield volumes in 526 normal control (NC) and early mild cognitive impairment (eMCI) participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI2; ADNI-GO). Regression moderation models showed that women- but not men- with NC designation did not show reduced subiculum volumes despite A+. At the eMCI stage, A+ was detrimental across sexes. Findings were significant while accounting for the effects of age, cognition at screening, education, and APOE4 carrier status. These findings suggest that women with A+ have early neural resistance to Alzheimer's disease-related amyloid burden.

  12. Imaging of Lipids and Metabolites Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanekoff, Ingela; Laskin, Julia

    In recent years, mass spectroscopy imaging (MSI) has emerged as a foundational technique in metabolomics and drug screening providing deeper understanding of complex mechanistic pathways within biochemical systems and biological organisms. We have been invited to contribute a chapter to a new Springer series volume, entitled “Mass Spectrometry Imaging of Small Molecules”. The volume is planned for the highly successful lab protocol series Methods in Molecular Biology, published by Humana Press, USA. The volume is aimed to equip readers with step-by-step mass spectrometric imaging protocols and bring rapidly maturing methods of MS imaging to life science researchers. The chapter willmore » provide a detailed protocol of ambient MSI by use of nanospray desorption electrospray ionization.« less

  13. Evaluation of thoracic radiographs as a screening test for dogs and cats admitted to a tertiary-care veterinary hospital for noncardiopulmonary disease.

    PubMed

    Keyserling, Christine L; Buriko, Yekaterina; Lyons, Bridget M; Drobatz, Kenneth J; Fischetti, Anthony J

    2017-09-01

    Thoracic radiographs are used as a screening tool for dogs and cats with a variety of disorders that have no clinical signs associated with thoracic structures. However, this practice has never been supported by an evidence-based study. The objective of this retrospective observational study was to determine if certain canine and feline populations have a higher proportion of radiographic abnormalities, and whether any of these abnormalities are associated with patient hospitalization and outcome. Patients were excluded if current or previous examinations revealed evidence of primary respiratory or cardiac disease, malignant neoplasia, or an abnormal breathing pattern consistent with pulmonary pathology. Any notable thoracic change in the radiology report was considered important and evaluated in this study. One hundred and sixty-six of these included patients were dogs and 65 were cats. Of the 166 dog radiographs evaluated, 120 (72.3%) had normal thoracic radiographs, while 46 (27.7%) had radiographic abnormalities. Of the sixty-five cats included, 36 (55.4%) had normal radiographs, while 29 (44.6%) had abnormal radiographs. Canine patients with abnormal radiographs had a significantly higher lactate level (P-value 0.0348) and feline patients with abnormal radiographs had a significantly lower packed cell volume (P-value 0.012). A large proportion of patients that had screening thoracic radiographs (32.5%) had documented abnormalities, but a relatively low percentage (6.5%) of our total population had their clinical plan changed as a consequence of detection of these abnormalities. Findings indicated that abnormal screening thoracic radiographs are more likely in dogs with an elevated lactate and cats with anemia, or a low normal hematocrit. © 2017 American College of Veterinary Radiology.

  14. Measurement and evaluation of digital cervicography programs in two cervical cancer screening camps in East Africa

    NASA Astrophysics Data System (ADS)

    Peterson, Curtis W.; Mink, Jonah; Levitz, David

    2017-03-01

    Cervical cancer disproportionately affects women living in low- and middle-income countries. To address this global crisis, many governments and NGOs have implemented community-based screening and treatment programs at outreach camps. Here, high volumes of patients are able to access care: screening and diagnosis followed by immediate treatment of precancerous lesions onsite. However, monitoring and evaluation (M&E) of these efforts presents challenges, since each event typically relies on a different health workforce, and refers patients to different facilities for follow up and advanced care. To address these challenges, a digital imaging intervention was deployed at several screening camps in East Africa. Trained nurses screened women using a connected low-cost mobile colposcope built around a smartphone. A decision support job aid was integrated into the app controlling the device, guiding nurses and recording their diagnosis and treatment decisions. Aggregating the data from the job aid allowed M&E of the screening camp in real-time. In this paper, the M&E data from 2 different screening camps in East Africa are compared. Additionally, screening camps are compared to stationary clinics. Differences in the patient screening times, treatment rates, and individual nurse statistics were all documented through the job aid allowing for much improved epidemiological information following outreach events thus enabling targeted program improvements and provider training. Reporting data from screening camps were also shared online via public web pages, facilitating broader dissemination of health needs in specific East African communities, and sparking conversations with regional stakeholders about local disease burden.

  15. Out-of-hospital stroke screen accuracy in a state with an emergency medical services protocol for routing patients to acute stroke centers.

    PubMed

    Asimos, Andrew W; Ward, Shana; Brice, Jane H; Rosamond, Wayne D; Goldstein, Larry B; Studnek, Jonathan

    2014-11-01

    Emergency medical services (EMS) protocols, which route patients with suspected stroke to stroke centers, rely on the use of accurate stroke screening criteria. Our goal is to conduct a statewide EMS agency evaluation of the accuracies of the Cincinnati Prehospital Stroke Scale (CPSS) and the Los Angeles Prehospital Stroke Screen (LAPSS) for identifying acute stroke patients. We conducted a retrospective study in North Carolina by linking a statewide EMS database to a hospital database, using validated deterministic matching. We compared EMS CPSS or LAPSS results (positive or negative) to the emergency department diagnosis International Classification of Diseases, Ninth Revision codes. We calculated sensitivity, specificity, and positive and negative likelihood ratios for the EMS diagnosis of stroke, using each screening tool. We included 1,217 CPSS patients and 1,225 LAPSS patients evaluated by 117 EMS agencies from 94 North Carolina counties. Most EMS agencies contributing data had high annual patient volumes and were governmental agencies with nonvolunteer, emergency medical technician-paramedic service level providers. The CPSS had a sensitivity of 80% (95% confidence interval [CI] 77% to 83%) versus 74% (95% CI 71% to 77%) for the LAPSS. Each had a specificity of 48% (CPSS 95% CI 44% to 52%; LAPSS 95% CI 43% to 53%). The CPSS and LAPSS had similar test characteristics, with each having only limited specificity. Development of stroke screening scales that optimize both sensitivity and specificity is required if these are to be used to determine transport diversion to acute stroke centers. Copyright © 2014. Published by Elsevier Inc.

  16. Estimation of non-solid lung nodule volume with low-dose CT protocols: effect of reconstruction algorithm and measurement method

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; DeFilippo, Gino; Berman, Benjamin P.; Li, Qin; Petrick, Nicholas; Schultz, Kurt; Siegelman, Jenifer

    2017-03-01

    Computed tomography is primarily the modality of choice to assess stability of nonsolid pulmonary nodules (sometimes referred to as ground-glass opacity) for three or more years, with change in size being the primary factor to monitor. Since volume extracted from CT is being examined as a quantitative biomarker of lung nodule size, it is important to examine factors affecting the performance of volumetric CT for this task. More specifically, the effect of reconstruction algorithms and measurement method in the context of low-dose CT protocols has been an under-examined area of research. In this phantom study we assessed volumetric CT with two different measurement methods (model-based and segmentation-based) for nodules with radiodensities of both nonsolid (-800HU and -630HU) and solid (-10HU) nodules, sizes of 5mm and 10mm, and two different shapes (spherical and spiculated). Imaging protocols included CTDIvol typical of screening (1.7mGy) and sub-screening (0.6mGy) scans and different types of reconstruction algorithms across three scanners. Results showed that radio-density was the factor contributing most to overall error based on ANOVA. The choice of reconstruction algorithm or measurement method did not affect substantially the accuracy of measurements; however, measurement method affected repeatability with repeatability coefficients ranging from around 3-5% for the model-based estimator to around 20-30% across reconstruction algorithms for the segmentation-based method. The findings of the study can be valuable toward developing standardized protocols and performance claims for nonsolid nodules.

  17. Nanoscale volume confinement and fluorescence enhancement with double nanohole aperture

    PubMed Central

    Regmi, Raju; Al Balushi, Ahmed A.; Rigneault, Hervé; Gordon, Reuven; Wenger, Jérôme

    2015-01-01

    Diffraction ultimately limits the fluorescence collected from a single molecule, and sets an upper limit to the maximum concentration to isolate a single molecule in the detection volume. To overcome these limitations, we introduce here the use of a double nanohole structure with 25 nm gap, and report enhanced detection of single fluorescent molecules in concentrated solutions exceeding 20 micromolar. The nanometer gap concentrates the light into an apex volume down to 70 zeptoliter (10−21 L), 7000-fold below the diffraction-limited confocal volume. Using fluorescence correlation spectroscopy and time-correlated photon counting, we measure fluorescence enhancement up to 100-fold, together with local density of optical states (LDOS) enhancement of 30-fold. The distinctive features of double nanoholes combining high local field enhancement, efficient background screening and relative nanofabrication simplicity offer new strategies for real time investigation of biochemical events with single molecule resolution at high concentrations. PMID:26511149

  18. PREDICTING ATTENUATION OF VIRUSES DURING PERCOLATION IN SOILS: 2. USER'S GUIDE TO THE VIRULO 1.0 COMPUTER MODEL

    EPA Science Inventory

    In the EPA document Predicting Attenuation of Viruses During Percolation in Soils 1. Probabilistic Model the conceptual, theoretical, and mathematical foundations for a predictive screening model were presented. In this current volume we present a User's Guide for the computer mo...

  19. Filtration Effects Due to Bioassay Cage Design and Screen Type

    DTIC Science & Technology

    2010-01-01

    Optical Nonimaging Light- Scattering Instruments (ASTM, 2003). Droplet sizing data included volume median diam (DV50), and the 10% and 90% diam (DV10 and...optical nonimaging light-scattering instru- ments. In: Annual book of ASTM standards. West Conshohocken, PA: American Society for Testing and Materials

  20. Quantitative assessment of smoking-induced emphysema progression in longitudinal CT screening for lung cancer

    NASA Astrophysics Data System (ADS)

    Suzuki, H.; Mizuguchi, R.; Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.; Moriyama, N.

    2015-03-01

    Computed tomography has been used for assessing structural abnormalities associated with emphysema. It is important to develop a robust CT based imaging biomarker that would allow quantification of emphysema progression in early stage. This paper presents effect of smoking on emphysema progression using annual changes of low attenuation volume (LAV) by each lung lobe acquired from low-dose CT images in longitudinal screening for lung cancer. The percentage of LAV (LAV%) was measured after applying CT value threshold method and small noise reduction. Progression of emphysema was assessed by statistical analysis of the annual changes represented by linear regression of LAV%. This method was applied to 215 participants in lung cancer CT screening for five years (18 nonsmokers, 85 past smokers, and 112 current smokers). The results showed that LAV% is useful to classify current smokers with rapid progression of emphysema (0.2%/year, p<0.05). This paper demonstrates effectiveness of the proposed method in diagnosis and prognosis of early emphysema in CT screening for lung cancer.

  1. Application of data screening to drug exposure in large risk factor studies of birth defects.

    PubMed

    Louik, Carol; Werler, Martha; Anderka, Marlene; Mitchell, Allen A

    2015-08-01

    Birth defects are the leading cause of infant death. While causes of most are unknown, those that might be due to medication use are among the most preventable. This study describes an approach to identifying those medications that most warrant attention by using a "screen" program that calculates odds ratios for pairs of exposures and specific birth defects. We discuss the development of this tool and illustrate its application to two large risk factor studies, the Slone Epidemiology Center's Birth Defects Study and the Centers for Disease Control and Prevention's National Birth Defects Prevention Study, ideal settings for the systematic study of risks and relative safety of drugs in relation to birth defects while recognizing the inherent limitations of such an approach. Suggestions for establishing criteria for exposures and outcomes that balance the need for specific details with the practical considerations of sample size and volume of output are presented. Selection of appropriate exposure reference categories and control groups is also discussed, as well as the need to address potential confounding. An example that motivated a detailed investigation of possible associations between a medication (butalbital) and selected specific birth defects is provided. While screening programs such as the one described can be a valuable tool for exploring potential associations in large data bases, they must be applied with caution. The issue of multiple testing and chance findings is a major concern. While statistics are a necessary component, human judgment must be an integral part of the process. © 2015 Wiley Periodicals, Inc.

  2. Mapping QTL for popping expansion volume in popcorn with simple sequence repeat markers.

    PubMed

    Lu, H-J; Bernardo, R; Ohm, H W

    2003-02-01

    Popping expansion volume is the most important quality trait in popcorn ( Zea mays L.), but its genetics is not well understood. The objectives of this study were to map quantitative trait loci (QTLs) responsible for popping expansion volume in a popcorn x dent corn cross, and to compare the predicted efficiencies of phenotypic selection, marker-based selection, and marker-assisted selection for popping expansion volume. Of 259 simple sequence repeat (SSR) primer pairs screened, 83 pairs were polymorphic between the H123 (dent corn) and AG19 (popcorn) parental inbreds. Popping test data were obtained for 160 S(1) families developed from the [AG19(H123 x AG19)] BC(1) population. The heritability ( h(2)) for popping expansion volume on an S(1) family mean basis was 0.73. The presence of the gametophyte factor Ga1(s) in popcorn complicates the analysis of popcorn x dent corn crosses. But, from a practical perspective, the linkage between a favorable QTL allele and Ga1(s) in popcorn will lead to selection for the favorable QTL allele. Four QTLs, on chromosomes 1S, 3S, 5S and 5L, jointly explained 45% of the phenotypic variation. Marker-based selection for popping expansion volume would require less time and work than phenotypic selection. But due to the high h(2) of popping expansion volume, marker-based selection was predicted to be only 92% as efficient as phenotypic selection. Marker-assisted selection, which comprises index selection on phenotypic and marker scores, was predicted to be 106% as efficient as phenotypic selection. Overall, our results suggest that phenotypic selection will remain the preferred method for selection in popcorn x dent corn crosses.

  3. Health promotion activities of sports clubs and coaches, and health and health behaviours in youth participating in sports clubs: the Health Promoting Sports Club study

    PubMed Central

    Kokko, Sami; Selänne, Harri; Alanko, Lauri; Heinonen, Olli J; Korpelainen, Raija; Savonen, Kai; Vasankari, Tommi; Kannas, Lasse; Kujala, Urho M; Aira, Tuula; Villberg, Jari; Parkkari, Jari

    2015-01-01

    Introduction Sports clubs form a potential setting for health promotion, but the research is limited. The aim of the Health Promoting Sports Club (HPSC) study was to elucidate the current health promotion activities of youth sports clubs and coaches, and to investigate the health behaviours and health status of youth participating in sports clubs compared to non-participants. Methods and analysis The study design employs cross-sectional multilevel and multimethod research with aspirations to a prospective cohort study in the next phase. The setting-based variables at sports clubs and coaching levels, and health behaviour variables at the individual level, are investigated using surveys; and total levels of physical activity are assessed using objective accelerometer measurements. Health status variables will be measured by preparticipation screening. The health promotion activity of sports clubs (n=154) is evaluated by club officials (n=313) and coaches (n=281). Coaches and young athletes aged 14–16 (n=759) years evaluate the coaches’ health promotion activity. The survey of the adolescents’ health behaviours consist of two data sets—the first is on their health behaviours and the second is on musculoskeletal complaints and injuries. Data are collected via sports clubs (759 participants) and schools 1650 (665 participants and 983 non-participants). 591 (418 athletes and 173 non-athletes) youth, have already participated in preparticipation screening. Screening consists of detailed personal medical history, electrocardiography, flow-volume spirometry, basic laboratory analyses and health status screening, including posture, muscle balance, and static and dynamic postural control tests, conducted by sports and exercise medicine specialists. Ethics and dissemination The HPSC study is carried out conforming with the declaration of Helsinki. Ethical approval was received from the Ethics Committee of Health Care District of Central Finland. The HPSC study is close-to-practice, which generates foundations for development work within youth sports clubs. PMID:27900129

  4. Health promotion activities of sports clubs and coaches, and health and health behaviours in youth participating in sports clubs: the Health Promoting Sports Club study.

    PubMed

    Kokko, Sami; Selänne, Harri; Alanko, Lauri; Heinonen, Olli J; Korpelainen, Raija; Savonen, Kai; Vasankari, Tommi; Kannas, Lasse; Kujala, Urho M; Aira, Tuula; Villberg, Jari; Parkkari, Jari

    2015-01-01

    Sports clubs form a potential setting for health promotion, but the research is limited. The aim of the Health Promoting Sports Club (HPSC) study was to elucidate the current health promotion activities of youth sports clubs and coaches, and to investigate the health behaviours and health status of youth participating in sports clubs compared to non-participants. The study design employs cross-sectional multilevel and multimethod research with aspirations to a prospective cohort study in the next phase. The setting-based variables at sports clubs and coaching levels, and health behaviour variables at the individual level, are investigated using surveys; and total levels of physical activity are assessed using objective accelerometer measurements. Health status variables will be measured by preparticipation screening. The health promotion activity of sports clubs (n=154) is evaluated by club officials (n=313) and coaches (n=281). Coaches and young athletes aged 14-16 (n=759) years evaluate the coaches' health promotion activity. The survey of the adolescents' health behaviours consist of two data sets-the first is on their health behaviours and the second is on musculoskeletal complaints and injuries. Data are collected via sports clubs (759 participants) and schools 1650 (665 participants and 983 non-participants). 591 (418 athletes and 173 non-athletes) youth, have already participated in preparticipation screening. Screening consists of detailed personal medical history, electrocardiography, flow-volume spirometry, basic laboratory analyses and health status screening, including posture, muscle balance, and static and dynamic postural control tests, conducted by sports and exercise medicine specialists. The HPSC study is carried out conforming with the declaration of Helsinki. Ethical approval was received from the Ethics Committee of Health Care District of Central Finland. The HPSC study is close-to-practice, which generates foundations for development work within youth sports clubs.

  5. Pharmacophore Identification, Molecular Docking, Virtual Screening, and In Silico ADME Studies of Non-Nucleoside Reverse Transcriptase Inhibitors.

    PubMed

    Pirhadi, Somayeh; Ghasemi, Jahan B

    2012-12-01

    Non-nucleoside reverse transcriptase inhibitors (NNRTIs) have gained a definitive place due to their unique antiviral potency, high specificity and low toxicity in antiretroviral combination therapies used to treat HIV. In this study, chemical feature based pharmacophore models of different classes of NNRT inhibitors of HIV-1 have been developed. The best HypoRefine pharmacophore model, Hypo 1, which has the best correlation coefficient (0.95) and the lowest RMS (0.97), contains two hydrogen bond acceptors, one hydrophobic and one ring aromatic feature, as well as four excluded volumes. Hypo 1 was further validated by test set and Fischer validation method. The best pharmacophore model was then utilized as a 3D search query to perform a virtual screening to retrieve potential inhibitors. The hit compounds were subsequently subjected to filtering by Lipinski's rule of five and docking studies by Libdock and Gold methods to refine the retrieved hits. Finally, 7 top ranked compounds based on Gold score fitness function were subjected to in silico ADME studies to investigate for compliance with the standard ranges. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Postradiation hypothyroidism in head and neck cancers: A Department of Veterans Affairs single-institution case-control dosimetry study.

    PubMed

    Lin, Alexander J; Zhang, Juying; Cho-Lim, Jennie; Inouye, Warren; Lee, Steve P

    2018-03-23

    We performed a case-control study to characterize the dose-volume relationship and other variables leading to hypothyroidism after head and neck (H&N) cancer radiation therapy (RT) in a homogenous Veterans Affairs (VA) population. All records of patients receiving RT for various H&N cancers at a single VA medical center between 2007 and 2013 (n = 143) were screened for post-RT thyroid stimulating hormone (TSH) levels (n = 77). The thyroid gland was contoured on each slice of the planning computed tomography scan when available (hypothyroid: n = 18; euthyroid > 2 years: n = 16), and dose-volume histograms based on physical dose and biologically equivalent dose (BED) were compared systematically to find the significant dose-volume thresholds that distinguish the patients who developed clinical hypothyroidism. Dosimetric and clinical variables were considered in univariate and multivariate analysis. Preirradiation prevalence of hypothyroidism was 8 of 143 (5.6%). After RT, 36 of 77 (47%) screened patients had abnormally high TSH, of which 22 of 36 (61%) had clinical hypothyroidism after 1.29 ± 0.99 years. The median follow-up durations were 3.3 years and 4.7 years for euthyroid and hypothyroid patients, respectively. Compared with the euthyroid cohort (n = 41), these hypothyroid patients displayed no significant difference in age, gender, primary tumor site, thyroid volume, hypertension, diabetes, or use of chemotherapy, surgery, or intensity-modulated radiation therapy (IMRT). They were more likely to have had stage 3 or 4 cancer than euthyroid patients (86.5% vs 73.2%, p = 0.01). The odds ratios of hypothyroidism for stage 3 + 4 cancers and V50Gy < 75% were 5.0 and 0.2, respectively (p < 0.05). Equivalent BED threshold of V75Gy 3  < 75% gave an odds ratio of 0.156 for developing hypothyroidism (p = 0.02). The prevalence of post-RT clinical hypothyroidism was relatively high for patients with H&N cancers and warrants routine surveillance, especially in those with higher stage malignancy. V50Gy < 75% may be a useful guideline to avoid hypothyroidism. We also show BED data which could be used for unconventionally fractionated schemes, and V75Gy 3  < 75% may be a useful guideline. Published by Elsevier Inc.

  7. Screening apatites for (U-Th)/He thermochronometry via continuous ramped heating: He age components and implications for age dispersion

    NASA Astrophysics Data System (ADS)

    McDannell, Kalin T.; Zeitler, Peter K.; Janes, Darwin G.; Idleman, Bruce D.; Fayon, Annia K.

    2018-02-01

    Old slowly-cooled apatites often yield dispersed (U-Th)/He ages for a variety of reasons, some well understood and some not. Analytical protocols like careful grain selection can reduce the impact of this dispersion but add costs in time and resources and too often have proven insufficient. We assess a new analytical protocol that utilizes static-gas measurement during continuous ramped heating (CRH) as a means to rapidly screen apatite samples. In about the time required for a conventional total-gas analysis, this method can discriminate between samples showing expected volume-diffusion behavior and those showing anomalous release patterns inconsistent with their direct use in thermochronologic applications. This method also appears able to discriminate between the radiogenic and extraneous 4He fractions released by a sample, potentially allowing ages to be corrected. Well-behaved examples such as the Durango standard and other apatites with good age reproducibility show the expected smooth, sigmoidal gas-release curves predicted for volume diffusion using typical apatite kinetics, with complete exhaustion by ∼900 °C for linear heating at 20 °C/min. Secondary factors such as U and Th zoning and alpha-loss distribution have a relatively minor impact on such profiles. In contrast, samples having greater age dispersion show significant He release in the form of outgassing spikes and He release deferred to higher temperatures. Screening results for a range of samples permit us to assess the degree to which CRH screening can identify misbehaving grains, give insight into the source of extraneous He, and suggest that in some cases it may be possible to correct ages for the presence of such components.

  8. Evaluation of staff performance and interpretation of the screening program for prevention of thalassemia.

    PubMed

    Prommetta, Simaporn; Sanchaisuriya, Kanokwan; Fucharoen, Goonnapa; Yamsri, Supawadee; Chaiboonroeng, Attawut; Fucharoen, Supan

    2017-06-15

    Thalassemia screening program has been implemented for years in Southeast Asia, but no external quality assessment program has been established. We have developed and initiated the proficiency testing (PT) program for the first time in Thailand with the aim to assess the screening performance of laboratory staff and their competency in interpretation of the screening results. Three PT cycles per year were organized. From the first to the third cycle of the PT scheme, a total number of participant laboratories increased from 59 to 67. In each cycle, 2 PT items (assigned as blood samples of the couple) were provided. Performance evaluation was based on the accuracy of screening results, i.e . mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH) and the dichlorophenolindophenol (DCIP) test for haemoglobin E, including the competency in interpretation of screening results and assessment of foetal risk. Performance was assessed by comparing the participants' result against the assigned value. Of all 3 cycles, most laboratories reported acceptable MCV and MCH values. From the first to the third cycle, incorrect DCIP test and misinterpretation rates were decreased while incorrect risk assessment varied by cycle to cycle. Combining the accuracy of thalassemia screening and the competency in interpretation and risk assessment, approximately half of participants showed excellent performance. Improved performance observed in many laboratories reflects the achievement and benefit of the PT program which should be regularly provided.

  9. The pros and cons of the fourth revision of thalassaemia screening programme in Iran.

    PubMed

    Moafi, Alireza; Vallian, Reihaneh; Vallian, Sadeq; Rahgozar, Soheila; Torfenajad, Mohammad; Moafi, Hadi

    2017-03-01

    Objective To evaluate the repercussions of recent changes to the cut-offs used in the first screening step of the pre-marital screening programme for thalassaemia prevention in Iran. Methods The profiles of 984 subjects referred to a genetic laboratory, and the tests of 242 parents of children with thalassaemia major were assessed for red blood cell (RBC) indices, haemoglobin (Hb) A2 levels and results of Hb electrophoresis. Results Of 407 suspected thalassaemia minor (STM) cases, 18 proved positive for thalassaemia minor on molecular analysis (18/407, confidence interval 2.6-6.9%). If the revised screening cut-offs had been used to determine who would undergo molecular analysis, two of these cases would not have been identified. Only 4.4% of suspected cases with lower than normal RBC indices (mean corpuscular volume <80 fl and mean corpuscular Hb <27 pg) and HbA2 (<3.5%) were diagnosed with thalassaemia minor. Conclusion The thalassaemia major prevention programme is performed in two separate steps. One step involves the screening of subjects and identification of β-thalassaemia minor, suspected cases for thalassaemia minor (STM), and normal subject groups. The other step concerns the identification of thalassaemia minor in the STM group. Changing the cut-offs at the first screening step does not result in significant improvement from an economic view, and is associated with significant risk at the second screening step.

  10. Experiences in implementing uHTS--cutting edge technology meets the real world.

    PubMed

    Gribbon, Philip; Schaertl, Sabine; Wickenden, Malcolm; Williams, Gareth; Grimley, Rachel; Stuhmeier, Frank; Preckel, Hartwig; Eggeling, Christian; Kraemer, Joachim; Everett, Jeremy; Keighley, Wilma W; Sewing, Andreas

    2004-01-01

    Driven by growing corporate compound files, the demands of target biology, and attempts to cut cost, the number of solutions to HTS has spiralled. In quick succession new assay technologies and screening platforms are appearing on the market, with the promise of screening faster than ever in low volume high density formats whilst providing high quality data. Within this world of rapid change, Pfizer has applied cutting edge technology to HTS by introducing screening in 1 microl formats utilising single molecule detection technology. Instead of resource intensive in-house development, Pfizer entered into a collaboration with Evotec OAI / Evotec Technologies and introduced their Mark-II EVOscreen platform. In this article we will outline the benefits of the approach taken at Pfizer, Sandwich, and introduce the Mark-II EVOscreen platform, illustrating the potential but also possible pitfalls of HTS miniaturisation.

  11. Correlation between hippocampal volumes and medial temporal lobe atrophy in patients with Alzheimer's disease.

    PubMed

    Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh

    2017-01-01

    Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly ( n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = -0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method ( P < 0.05). Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD.

  12. Correlation between hippocampal volumes and medial temporal lobe atrophy in patients with Alzheimer's disease

    PubMed Central

    Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh

    2017-01-01

    Introduction: Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. Materials and Methods: We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. Results: There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly (n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = −0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method (P < 0.05). Conclusions: Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD. PMID:28298839

  13. Impact of HPV testing, HPV vaccine development, and changing screening frequency on national Pap test volume: projections from the National Health Interview Survey (NHIS).

    PubMed

    Eltoum, Isam A; Roberson, Janie

    2007-02-25

    The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future. This, in turn, will decrease the demand for a traditionally trained cytotechnology workforce. (c) 2007 American Cancer Society.

  14. Flow Cytometry: Impact on Early Drug Discovery.

    PubMed

    Edwards, Bruce S; Sklar, Larry A

    2015-07-01

    Modern flow cytometers can make optical measurements of 10 or more parameters per cell at tens of thousands of cells per second and more than five orders of magnitude dynamic range. Although flow cytometry is used in most drug discovery stages, "sip-and-spit" sampling technology has restricted it to low-sample-throughput applications. The advent of HyperCyt sampling technology has recently made possible primary screening applications in which tens of thousands of compounds are analyzed per day. Target-multiplexing methodologies in combination with extended multiparameter analyses enable profiling of lead candidates early in the discovery process, when the greatest numbers of candidates are available for evaluation. The ability to sample small volumes with negligible waste reduces reagent costs, compound usage, and consumption of cells. Improved compound library formatting strategies can further extend primary screening opportunities when samples are scarce. Dozens of targets have been screened in 384- and 1536-well assay formats, predominantly in academic screening lab settings. In concert with commercial platform evolution and trending drug discovery strategies, HyperCyt-based systems are now finding their way into mainstream screening labs. Recent advances in flow-based imaging, mass spectrometry, and parallel sample processing promise dramatically expanded single-cell profiling capabilities to bolster systems-level approaches to drug discovery. © 2015 Society for Laboratory Automation and Screening.

  15. Co-inheritance of α-thalassaemia and β-thalassaemia in a prenatal screening population in mainland China.

    PubMed

    Li, Jian; Xie, Xing-Mei; Liao, Can; Li, Dong-Zhi

    2014-12-01

    To determine the prevalence of α-thalassaemia in β-thalassaemia individuals in a Chinese population. The standard diagnostic marker for β-thalassaemia was elevation of the Hb A2 level (>3.5%) with low mean corpuscular volume. The common α-thalassaemia mutations were studied by molecular analysis in all identified β-thalassaemia carriers. A prevalence rate of 3.3% for β-thalassaemia was found in our population; α- and β-thalassaemia interactions were found to co-exist in 17.8% of the β-thalassaemia carriers. The -SEA deletion was the most common α-thalassaemia mutation co-inherited with β-thalassaemia, followed by the -α3.7 deletion, the -α4.2 deletion, Hb Quong Sze, and Hb Constant Spring. Our results suggest that it could be valuable to study co-existing α-globin mutations in subjects with β-thalassaemia trait in a prenatal screening programme, especially in populations with a high prevalence of haemoglobinopathies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Shoulder muscle volume and fat content in healthy adult volunteers: quantification with DIXON MRI to determine the influence of demographics and handedness.

    PubMed

    Kälin, Pascal S; Crawford, Rebecca J; Marcon, Magda; Manoliu, Andrei; Bouaicha, Samy; Fischer, Michael A; Ulbrich, Erika J

    2018-04-23

    We aimed to provide mean values for fat-fraction and volume for full-length bilateral rotator cuff and deltoid muscles in asymptomatic adults selected on the basis of their good musculoskeletal and systemic health, and to understand the influence of gender, age, and arm dominance. Seventy-six volunteers aged 20 to 60 years who were screened for normal BMI and high general health were included in the study. MRI was performed at 3 Tesla using three-point DIXON sequences. Volume and fat-signal fraction of the rotator cuff muscles and the deltoid muscle were determined with semi-automated segmentation of entire muscle lengths. Differences according to age, gender, and handedness per muscle were evaluated. Fat-signal fractions were comparable between genders (mean ± 2 SD, 95% CI, women 7.0 ± 3.0; 6.8-7.2%, men 6.8 ± 2.7; 6.7-7.0%) but did not show convincing changes with age. Higher shoulder muscle volume and lower fat-signal fraction in the dominant arm were shown for teres minor and deltoid (p < 0.01) with similar trends shown for the other rotator cuff muscles. Bilateral fat-signal fractions and volumes based on entire length shoulder muscles in asymptomatic 20-60 year old adults may provide reference for clinicians. Differences shown according to arm dominance should be considered and may rationalize the need for bilateral imaging in determining appropriate management.

  17. The utility of Google Trends data to examine interest in cancer screening.

    PubMed

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-06-08

    We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. State-level data across the USA. Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. The volume of nipple aspirate fluid is not affected by 6 months of treatment with soy foods in premenopausal women.

    PubMed

    Maskarinec, Gertraud; Morimoto, Yukiko; Conroy, Shannon M; Pagano, Ian S; Franke, Adrian A

    2011-04-01

    Based on the hypothesis that soy food consumption may influence breast tissue activity, we examined its effect on the production of nipple aspirate fluid (NAF), a possible indicator of breast cancer risk. Of 310 premenopausal women screened, 112 (36%) produced at least 10 μL of NAF, the minimum for study participation. In a crossover design, we randomized 96 women to 2 groups who, in reverse order, consumed a high-soy diet with 2 soy servings/d (1 serving = 177 mL soy milk, 126 g tofu, or 23 g soy nuts) and a low-soy diet with <3 servings/wk of soy for 6 mo each separated by a 1-mo washout period. During each diet period, 3 NAF samples were obtained (baseline and 3 and 6 mo) using a FirstCyte Aspirator and 4 urine samples (baseline and 1, 3, and 6 mo) were analyzed for isoflavonoids by liquid chromatography tandem MS. Adherence to the study protocol according to 24-h dietary recalls and urinary isoflavonoid excretion was high. The drop-out rate was 15% (n = 14); 82 women completed the intervention. The 2 groups produced similar mean NAF volumes at baseline (P = 0.95) but differed in age and previous soy intake and in their response to the intervention (P = 0.03). In both groups, NAF volume decreased during the first 3 mo of the high-soy diet period and returned to baseline at 6 mo, but there was no effect of the high-soy diet on NAF volume (P = 0.50 for diet; P-interaction = 0.21 for diet with time). Contrary to an earlier report, soy foods in amounts consumed by Asians did not increase breast tissue activity as assessed by NAF volume.

  19. The Volume of Nipple Aspirate Fluid Is Not Affected by 6 Months of Treatment with Soy Foods in Premenopausal Women1234

    PubMed Central

    Maskarinec, Gertraud; Morimoto, Yukiko; Conroy, Shannon M.; Pagano, Ian S.; Franke, Adrian A.

    2011-01-01

    Based on the hypothesis that soy food consumption may influence breast tissue activity, we examined its effect on the production of nipple aspirate fluid (NAF), a possible indicator of breast cancer risk. Of 310 premenopausal women screened, 112 (36%) produced at least 10 μL of NAF, the minimum for study participation. In a crossover design, we randomized 96 women to 2 groups who, in reverse order, consumed a high-soy diet with 2 soy servings/d (1 serving = 177 mL soy milk, 126 g tofu, or 23 g soy nuts) and a low-soy diet with <3 servings/wk of soy for 6 mo each separated by a 1-mo washout period. During each diet period, 3 NAF samples were obtained (baseline and 3 and 6 mo) using a FirstCyte Aspirator and 4 urine samples (baseline and 1, 3, and 6 mo) were analyzed for isoflavonoids by liquid chromatography tandem MS. Adherence to the study protocol according to 24-h dietary recalls and urinary isoflavonoid excretion was high. The drop-out rate was 15% (n = 14); 82 women completed the intervention. The 2 groups produced similar mean NAF volumes at baseline (P = 0.95) but differed in age and previous soy intake and in their response to the intervention (P = 0.03). In both groups, NAF volume decreased during the first 3 mo of the high-soy diet period and returned to baseline at 6 mo, but there was no effect of the high-soy diet on NAF volume (P = 0.50 for diet; P-interaction = 0.21 for diet with time). Contrary to an earlier report, soy foods in amounts consumed by Asians did not increase breast tissue activity as assessed by NAF volume. PMID:21325473

  20. Ovarian volume and gluco-insulinaemic markers in the diagnosis of PCOS during adolescence.

    PubMed

    Villa, Paola; Rossodivita, Aurora; Sagnella, Francesca; Moruzzi, Maria Cristina; Mariano, Nicoletta; Lassandro, Anna Pia; Pontecorvi, Alfredo; Scambia, Giovanni; Lanzone, Antonio

    2013-02-01

    To evaluate the role of mean ovarian volume (MOV) in the diagnosis of polycystic ovary syndrome (PCOS) during adolescence, and its relationship with metabolic and endocrine parameters. Observational study. A total of 134 young girls, including 86 adolescents with PCOS and 48 controls, were studied. During the early follicular phase, a pelvic ultrasound examination was performed to measure the ovarian volume of both ovaries and to calculate the MOV. All subjects underwent hormonal assessment and an ultrasound examination. PCOS subjects were submitted to an oral glucose tolerance test. The homeostasis model assessment for insulin resistance (HOMA-IR) and several insulin resistance indexes were also determined. Androgens, free androgen index (FAI), LH and insulin resistance indexes were higher in the PCOS group. MOV was significantly different between the two groups: control group 4·6 ± 1·9 cm(3) , adolescent PCOS group 9·6 ± 4·4 cm(3) . The MOV threshold of 5·596 cm(3) offered the best compromise between sensitivity and specificity based on the characteristics of the operating receiver curve analysis. Therefore, an ovarian volume higher than 5·6 increased the risk of PCOS by about 15 times (OR 16·25 IC 95% 6·3-41·3). In adolescent PCOS girls, the ovarian volume was significantly associated with circulating testosterone and insulin, and indices of insulin resistance. During early adolescence MOV evaluation may offer an effective means to screen and follow up young girls with irregular cycles in order to prevent the long-term metabolic disturbances of the polycystic ovary syndrome. © 2012 Blackwell Publishing Ltd.

  1. Cingulo-insular structural alterations associated with psychogenic symptoms, childhood abuse and PTSD in functional neurological disorders.

    PubMed

    Perez, David L; Matin, Nassim; Barsky, Arthur; Costumero-Ramos, Victor; Makaretz, Sara J; Young, Sigrid S; Sepulcre, Jorge; LaFrance, W Curt; Keshavan, Matcheri S; Dickerson, Bradford C

    2017-06-01

    Adverse early-life events are predisposing factors for functional neurological disorder (FND) and post-traumatic stress disorder (PTSD). Cingulo-insular regions are implicated in the biology of both conditions and are sites of stress-mediated neuroplasticity. We hypothesised that functional neurological symptoms and the magnitude of childhood abuse would be associated with overlapping anterior cingulate cortex (ACC) and insular volumetric reductions, and that FND and PTSD symptoms would map onto distinct cingulo-insular areas. This within-group voxel-based morphometry study probes volumetric associations with self-report measures of functional neurological symptoms, adverse life events and PTSD symptoms in 23 mixed-gender FND patients. Separate secondary analyses were also performed in the subset of 18 women with FND to account for gender-specific effects. Across the entire cohort, there were no statistically significant volumetric associations with self-report measures of functional neurological symptom severity or childhood abuse. In women with FND, however, parallel inverse associations were observed between left anterior insular volume and functional neurological symptoms as measured by the Patient Health Questionnaire-15 and the Screening for Somatoform Symptoms Conversion Disorder subscale. Similar inverse relationships were also appreciated between childhood abuse burden and left anterior insular volume. Across all subjects, PTSD symptom severity was inversely associated with dorsal ACC volume, and the magnitude of lifetime adverse events was inversely associated with left hippocampal volume. This study reveals distinct cingulo-insular alterations for FND and PTSD symptoms and may advance our understanding of FND. Potential biological convergence between stress-related neuroplasticity, functional neurological symptoms and reduced insular volume was identified. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Preparation and Characterization of Cabamazepine Cocrystal in Polymer Solution.

    PubMed

    Zhang, Hao; Zhu, Ying; Qiao, Ning; Chen, Yang; Gao, Linghuan

    2017-12-01

    In this study, we attempted to prepare carbamazepine (CBZ) cocrystal through the solution method in ethanol-water solvent mixture (volume ratio 1:1) and polyvinyl pyrrolidone (PVP) solution. Nicotinamide (NIC) and saccharin (SAC) were selected as cocrystal coformers. Cocrystal screening products were characterized by Fourier Transform Infrared Spectroscopy (FTIR), Differential Scanning Calorimetry (DSC), and Powder X-ray Diffraction (PXRD) techniques. Characterization results show that in ethanol-water solvent mixture, pure CBZ-NIC cocrystal can be prepared, while CBZ-SAC cocrystal cannot be obtained. The addition of PVP can inhibit CBZ-NIC cocrystal formation and facilitate CBZ-SAC cocrystal formation.

  3. Preparation and Characterization of Carbamazepine Cocrystal in Polymer Solution

    PubMed Central

    Zhang, Hao; Zhu, Ying; Chen, Yang; Gao, Linghuan

    2017-01-01

    In this study, we attempted to prepare carbamazepine (CBZ) cocrystal through the solution method in ethanol-water solvent mixture (volume ratio 1:1) and polyvinyl pyrrolidone (PVP) solution. Nicotinamide (NIC) and saccharin (SAC) were selected as cocrystal coformers. Cocrystal screening products were characterized by Fourier Transform Infrared Spectroscopy (FTIR), Differential Scanning Calorimetry (DSC), and Powder X-ray Diffraction (PXRD) techniques. Characterization results show that in ethanol-water solvent mixture, pure CBZ-NIC cocrystal can be prepared, while CBZ-SAC cocrystal cannot be obtained. The addition of PVP can inhibit CBZ-NIC cocrystal formation and facilitate CBZ-SAC cocrystal formation. PMID:29194387

  4. A Literature Review - Problem Definition Studies on Selected Toxic Chemicals. Volume 4. Occupational Health and Safety Aspects of the Fog Oils SGF No. 1 and SGF No. 2 and Smoke Screens Generated from Them

    DTIC Science & Technology

    1978-04-01

    deaths, no weight losses, and no abnormal hematological findings (8). b. Rabbits In groups of rabbits intermittently exposed to diesel fumes, Samal et al...lymphocyto- penia; watery bone marrow; dermatitis rabbits diesel fuel and motor reduced antibody produc- Samal I_ ,., oil fumes (100:6 mix- tion to...Laboratory Report No. 46, 1945. 91. Samal , U. C., R. Saran, R. K. Sanyal: Effects of inhaled fumes on immunological response of rabbits. Indian J Physiol

  5. The sensitivity of relative toxicity rankings by the USF/NASA test method to some test variables

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Labossiere, L. A.; Leon, H. A.; Kourtides, D. A.; Parker, J. A.; Hsu, M.-T. S.

    1976-01-01

    Pyrolysis temperature and the distance between the source and sensor of effluents are two important variables in tests for relative toxicity. Modifications of the USF/NASA toxicity screening test method to increase the upper temperature limit of pyrolysis, reduce the distance between the sample and the test animals, and increase the chamber volume available for animal occupancy, did not significantly alter rankings of relative toxicity of four representative materials. The changes rendered some differences no longer significant, but did not reverse any rankings. The materials studied were cotton, wool, aromatic polyamide, and polybenzimidazole.

  6. Attitude stabilization of a spacecraft equipped with large electrostatic protection screens

    NASA Astrophysics Data System (ADS)

    Nikitin, D. Yu.; Tikhonov, A. A.

    2018-05-01

    A satellite with a system of three electrostatic radiation protection (ERP) screens is under consideration. The screens are constructed as electrostatically charged toroidal shields with characteristic size of order equal to 100 m. The interaction of electric charge with the Earth's magnetic field (EMF) give rise to the Lorentz torque acting upon a satellite attitude motion. As the sizes of ERP system are large, we derive the Lorentz torque taking into account the complex form of ERP screens and gradient of the EMF in the screen volume. It is assumed that the satellite center of charge coincides with the satellite mass center. The EMF is modeled by the straight magnetic dipole. In the paper we investigate the usage of Lorentz torque for passive attitude stabilization for satellite in a circular equatorial orbit. Mathematical model for attitude dynamics of a satellite equipped with ERP interacting with the EMF is derived and first integral of corresponding differential equations is constructed. The straight equilibrium position of the satellite in the orbital frame is found. Sufficient conditions for stability of satellite equilibrium position are constructed with the use of the first integral. The gravity gradient torque is taken into account. The satellite equilibrium stability domain is constructed.

  7. Semiautomated Sample Preparation for Protein Stability and Formulation Screening via Buffer Exchange.

    PubMed

    Ying, William; Levons, Jaquan K; Carney, Andrea; Gandhi, Rajesh; Vydra, Vicky; Rubin, A Erik

    2016-06-01

    A novel semiautomated buffer exchange process workflow was developed to enable efficient early protein formulation screening. An antibody fragment protein, BMSdab, was used to demonstrate the workflow. The process afforded 60% to 80% cycle time and scientist time savings and significant material efficiencies. These efficiencies ultimately facilitated execution of this stability work earlier in the drug development process, allowing this tool to inform the developability of potential candidates for development from a formulation perspective. To overcome the key technical challenges, the protein solution was buffer-exchanged by centrifuge filtration into formulations for stability screening in a 96-well plate with an ultrafiltration membrane, leveraging automated liquid handling and acoustic volume measurements to allow several cycles of exchanges. The formulations were transferred into a vacuum manifold and sterile filtered into a rack holding 96 glass vials. The vials were sealed with a capmat of individual caps and placed in stability stations. Stability of the samples prepared by this process and by the standard process was demonstrated to be comparable. This process enabled screening a number of formulations of a protein at an early pharmaceutical development stage with a short sample preparation time. © 2015 Society for Laboratory Automation and Screening.

  8. Novel Acoustic Loading of a Mass Spectrometer: Toward Next-Generation High-Throughput MS Screening.

    PubMed

    Sinclair, Ian; Stearns, Rick; Pringle, Steven; Wingfield, Jonathan; Datwani, Sammy; Hall, Eric; Ghislain, Luke; Majlof, Lars; Bachman, Martin

    2016-02-01

    High-throughput, direct measurement of substrate-to-product conversion by label-free detection, without the need for engineered substrates or secondary assays, could be considered the "holy grail" of drug discovery screening. Mass spectrometry (MS) has the potential to be part of this ultimate screening solution, but is constrained by the limitations of existing MS sample introduction modes that cannot meet the throughput requirements of high-throughput screening (HTS). Here we report data from a prototype system (Echo-MS) that uses acoustic droplet ejection (ADE) to transfer femtoliter-scale droplets in a rapid, precise, and accurate fashion directly into the MS. The acoustic source can load samples into the MS from a microtiter plate at a rate of up to three samples per second. The resulting MS signal displays a very sharp attack profile and ions are detected within 50 ms of activation of the acoustic transducer. Additionally, we show that the system is capable of generating multiply charged ion species from simple peptides and large proteins. The combination of high speed and low sample volume has significant potential within not only drug discovery, but also other areas of the industry. © 2015 Society for Laboratory Automation and Screening.

  9. Pancreatic ductal adenocarcinoma: Risk factors, screening, and early detection

    PubMed Central

    Becker, Andrew E; Hernandez, Yasmin G; Frucht, Harold; Lucas, Aimee L

    2014-01-01

    Pancreatic cancer is the fourth most common cause of cancer-related deaths in the United States, with over 38000 deaths in 2013. The opportunity to detect pancreatic cancer while it is still curable is dependent on our ability to identify and screen high-risk populations before their symptoms arise. Risk factors for developing pancreatic cancer include multiple genetic syndromes as well as modifiable risk factors. Genetic conditions include hereditary breast and ovarian cancer syndrome, Lynch Syndrome, familial adenomatous polyposis, Peutz-Jeghers Syndrome, familial atypical multiple mole melanoma syndrome, hereditary pancreatitis, cystic fibrosis, and ataxia-telangiectasia; having a genetic predisposition can raise the risk of developing pancreatic cancer up to 132-fold over the general population. Modifiable risk factors, which include tobacco exposure, alcohol use, chronic pancreatitis, diet, obesity, diabetes mellitus, as well as certain abdominal surgeries and infections, have also been shown to increase the risk of pancreatic cancer development. Several large-volume centers have initiated such screening protocols, and consensus-based guidelines for screening high-risk groups have recently been published. The focus of this review will be both the genetic and modifiable risk factors implicated in pancreatic cancer, as well as a review of screening strategies and their diagnostic yields. PMID:25170203

  10. Naval War College. Volume 60, Number 2, Spring 2007

    DTIC Science & Technology

    2007-01-01

    attacks of grave conse- quences. The aspiration of this small-wars force element is to prevent even one nuclear, biological , or chemical weapon attack...153 Preventive Attack and Weapons of Mass...Default screen Bioethics and Armed Conflict: Moral Dilemmas of Medicine and War, by Michael L. Gross reviewed by Arthur M. Smith, MD

  11. Medical Surveillance Monthly Report. Volume 19, Number 7

    DTIC Science & Technology

    2012-07-01

    education for recruits at acces- sion. While the Marine Corps and...other Services. This may reflect that most servicewomen receive chlamydia screening, treatment and education imme- diately upon accession, while... hemoglobin , the substance in red blood cells (RBCs) that carries oxygen from the lungs to the rest of the body. In the face of

  12. U.S. Army Medical Bioengineering Research and Development Laboratory Annual Progress Report FY 1985. Volume 1

    DTIC Science & Technology

    1985-10-01

    heterotrophic carbon dioxide fixa- tion. An assay for T2 toxin using the yeast Cryptococcus luteolus was evaluated as a rapid screening device for toxic...Bioassay for Mycotoxins Using Cryptococcus luteolus with Tetrazolium Salts." Poster session at the American Soc. for Microbiol. Annual Meeting, March

  13. SUBSURFACE CHARACTERIZATION AND MONITORING TECHNIQUES: A DESK REFERENCE GUIDE - VOLUME II: THE VADOSE ZONE, FIELD SCREENING AND ANALYTICAL METHODS - APPENDICES C AND D

    EPA Science Inventory

    Many EPA programs, including those under the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Response, Compensation, and Liability Act (CERCLA), require subsurface characterization and monitoring to detect ground-water contamination and provide data to deve...

  14. MX Siting Investigation Geotechnical Evaluation Conterminous United States. Volume II. Intermediate Screening.

    DTIC Science & Technology

    1977-12-21

    sections of the CSP ( Thordarson and others, 1967; Figure 8). Interbedded materials consist of agglomerates, air-fall and ash-flow tuffs which are welded to...of Economic Geology, 1977, Land resource map of Texas: Bur. Econ. Geol., Univ. Texas, Austin, Texas. (in press). Thordarson , W., Young, R.A., and

  15. Colorectal tumors within an urban minority population in New York City.

    PubMed

    Kanna, Balavenkatesh; Schori, Melissa; Azeez, Sulaiman; Kumar, Suresh; Soni, Anita

    2007-06-01

    Data on gender- and age-specific predisposition to colorectal tumors and colorectal tumor location and stage among the urban minority population in Northeastern United States is limited. To study the age and gender distribution of colorectal tumor type, location, and stage of colorectal tumors among urban minorities. Retrospective analysis of a database of 4,043 consecutive colonoscopies performed over a 2-year period. PARTICIPANTS/MEASUREMENTS: Of study participants, 99% were Hispanic or African American and two-thirds were women. Age, gender, colonoscopy findings, and biopsy results were analyzed in all study subjects. Outcome measures are expressed as odds ratios (OR) with 95% confidence intervals (CI). Colonoscopies, 2,394 (63.4%), were performed for cancer screening. Women had higher visit volume adjusted odds to undergo colonoscopy (OR 1.35; CI 1.26-1.44, P < .001). Individuals, 960 (23.7%), had adenomas, and 82 (2.0%) had colorectal cancer. Although cancers were outnumbered by adenomas in the colon proximal to splenic flexure (OR 0.48; CI 0.29-0.80 P = .002), 51% of all abnormalities and 35.4% of cancers were found in this region. Of cancers, 75% belonged to AJCC stage 0 to 2. Men had higher odds for both adenomas and cancers (OR 2.38, CI 2.0-2.82, P < .001). More polyps occurred at a younger age. Of the cancers, 38% were noted among the 50- to 59-year-old subjects. However, the odds of colorectal cancers were higher at age greater than 70 years (OR 1.91; CI 1.09-3.27, P < .05), specifically among men (OR 2.27, 95% CI 1.07-4.65, P < .05). Our study of colonoscopies demonstrates lower odds of colonoscopy after adjusting for visit volume and greater predilection for colorectal cancer among urban minority men. Although older individuals were more likely to have colorectal cancer, a high percentage of colorectal tumors were noted at a younger age. These findings emphasize the vital need for preventive health education and improving early access to colorectal screening among urban minority men. A large proportion of colorectal tumors were found proximal to splenic flexure, which supports colonoscopy as the preferred method for colorectal cancer screening in the urban minority population in New York City.

  16. Comparison between mixed and spatially separated remote phosphor fabricated via a screen-printing process

    NASA Astrophysics Data System (ADS)

    Kim, Byung-Ho; Hwang, Jonghee; Lee, Young Jin; Kim, Jin-Ho; Jeon, Dae-Woo; Lee, Mi Jai

    2016-08-01

    We developed a fabrication method for remote phosphor by a screen-printing process, using green phosphor, red phosphor, and thermally stable glass frit. The glass frit was introduced for long-term stability. The optical properties of the remote phosphor were observed via an integrating sphere; the photoluminescence spectrum dramatically changed on incorporating a minor amount of the red phosphor. These unique optical properties were elucidated using four factors: phosphor ratio, scattering induced by packing density, light intensity per unit volume, and reabsorption. The thermal stability of the remote phosphor was investigated at 500°C, demonstrating its outstanding thermal properties.

  17. New biosensors for food safety screening solutions

    NASA Astrophysics Data System (ADS)

    Dyer, Maureen A.; Oberholtzer, Jennifer A.; Mulligan, David C.; Hanson, William P.

    2009-05-01

    Hanson Technologies has developed the automated OmniFresh 1000 system to sample large volumes of produce wash water, collect the pathogens, and detect their presence. By collecting a continuous sidestream of wash water, the OmniFresh uses a sample that represent the entire lot of produce being washed. The OmniFresh does not require bacterial culture or enrichment, and it detects both live and dead bacteria in the collected sample using an in-line sensor. Detection occurs in an array biosensor capable of handling large samples with complex matrices. Additionally, sample can be sent for traditional confirming tests after the screening performed by the OmniFresh.

  18. Mammographic Breast Density Evaluation in Korean Women Using Fully Automated Volumetric Assessment

    PubMed Central

    2016-01-01

    The purpose was to present mean breast density of Korean women according to age using fully automated volumetric assessment. This study included 5,967 screening normal or benign mammograms (mean age, 46.2 ± 9.7; range, 30–89 years), from cancer-screening program. We evaluated mean fibroglandular tissue volume, breast tissue volume, volumetric breast density (VBD), and the results were 53.7 ± 30.8 cm3, 383.8 ± 205.2 cm3, and 15.8% ± 7.3%. The frequency of dense breasts and mean VBD by age group were 94.3% and 19.1% ± 6.7% for the 30s (n = 1,484), 91.4% and 17.2% ± 6.8% for the 40s (n = 2,706), 72.2% and 12.4% ± 6.2% for the 50s (n = 1,138), 44.0% and 8.6% ± 4.3% for the 60s (n = 89), 39.1% and 8.0% ± 3.8% for the 70s (n = 138), and 39.1% and 8.0% ± 3.5% for the 80s (n = 12). The frequency of dense breasts was higher in younger women (n = 4,313, 92.3%) than older women (n = 1,654, 59.8%). Mean VBD decreased with aging or menopause, and was about 16% for 46-year-old-Korean women, much higher than in other countries. The proportion of dense breasts sharply decreases in Korean women between 40 and 69 years of age. PMID:26955249

  19. Accuracy of the volume-viscosity swallow test for clinical screening of oropharyngeal dysphagia and aspiration.

    PubMed

    Clavé, Pere; Arreola, Viridiana; Romea, Maise; Medina, Lucía; Palomera, Elisabet; Serra-Prat, Mateu

    2008-12-01

    To determine the accuracy of the bedside volume-viscosity swallow test (V-VST) for clinical screening of impaired safety and efficacy of deglutition. We studied 85 patients with dysphagia and 12 healthy subjects. Series of 5-20 mL nectar (295.02 mPa.s), liquid (21.61 mPa.s) and pudding (3682.21 mPa.s) bolus were administered during the V-VST and videofluoroscopy. Cough, fall in oxygen saturation > or =3%, and voice changes were considered signs of impaired safety, and piecemeal deglutition and oropharyngeal residue, signs of impaired efficacy. Videofluoroscopy showed patients had prolonged swallow response (> or =1064 ms); 52.1% had safe swallow at nectar, 32.9%, at liquid (p<0.05), and 80.6% at pudding viscosity (p<0.05); 29.4% had aspirations, and 45.8% oropharyngeal residue. The V-VST showed 83.7% sensitivity and 64.7% specificity for bolus penetration into the larynx and 100% sensitivity and 28.8% specificity for aspiration. Sensitivity of V-VST was 69.2% for residue, 88.4% for piecemeal deglutition, and 84.6% for identifying patients whose deglutition improved by enhancing bolus viscosity. Specificity was 80.6%, 87.5%, and 73.7%, respectively. The V-VST is a sensitive clinical method to identify patients with dysphagia at risk for respiratory and nutritional complications, and patients whose deglutition could be improved by enhancing bolus viscosity. Patients with a positive test should undergo videofluoroscopy.

  20. Impact of Body Mass Index, Age, Prostate Volume, and Genetic Polymorphisms on Prostate-specific Antigen Levels in a Control Population.

    PubMed

    Cornu, Jean-Nicolas; Cancel-Tassin, Geraldine; Cox, David G; Roupret, Morgan; Koutlidis, Nicolas; Bigot, Pierre; Valeri, Antoine; Ondet, Valerie; Gaffory, Cécile; Fournier, Georges; Azzouzi, Abdel-Rahmene; Cormier, Luc; Cussenot, Olivier

    2016-07-01

    Prostate-specific antigen (PSA) is still the cornerstone of prostate cancer (PCa) screening and diagnosis in both research and current clinical practice. Inaccuracy of PSA is partly due to the influence of a number of genetic, clinical, and biological factors modifying PSA blood levels. In the present study, we detailed the respective influence of each factor among age, body mass index (BMI), prostate volume, and five single-nucleotide polymorphisms-rs10788160 (10q26), rs10993994 (10q11), rs11067228 (12q24), rs17632542 (19q13.33), and rs2928679 (8p21)-on PSA values in a cohort of 1374 men without PCa. Our results show that genetic factors, when risk variants are combined, influence PSA levels with an effect size similar to that of BMI. Taken together, the respective correlations of clinical parameters and genetic parameters would make it possible to correct and adjust PSA values more effectively in each individual. These results establish the basis to understand and implement a more personalised approach for the interpretation of PSA blood levels in the context of PCa screening and diagnosis. Prostate-specific antigen (PSA) values in an individual may vary according to genetic predisposition. The effect size of this variation can be significant, comparable with those resulting from clinical characteristics. Personalised PSA testing should take this into account. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  1. Enteropathogen infections in canine puppies: (Co-)occurrence, clinical relevance and risk factors.

    PubMed

    Duijvestijn, Mirjam; Mughini-Gras, Lapo; Schuurman, Nancy; Schijf, Wim; Wagenaar, Jaap A; Egberink, Herman

    2016-11-15

    Laboratory confirmation of the causative agent(s) of diarrhoea in puppies may allow for appropriate treatment. The presence of potential pathogens however, does not prove a causal relationship with diarrhoea. The aim of this study was to identify specific enteropathogens in ≤12 month old puppies with and without acute diarrhoea and to assess their associations with clinical signs, putative risk factors and pathogen co-occurrence. Faecal samples from puppies with (n=113) and without (n=56) acute diarrhoea were collected and screened for Canine Parvovirus (CPV), Canine Coronavirus (CCoV), Salmonella spp., Campylobacter spp., Clostridium perfringens, Clostridium difficile, β-hemolytic Eschericha coli (hEC), Giardia spp., Toxocara spp., Cystoisospora spp., and Cyniclomyces guttulatus. One or more pathogens were detected in 86.5% of diarrhoeic puppies and in 77.8% of asymptomatic puppies. Significant positive associations were found between CPV and CCoV, CPV and Cystoisospora spp., Toxocara spp. and hEC, Giardia spp. and C. guttulatus. Only CPV and CCoV were significantly associated with diarrhoea, hEC with a subset of puppies that had diarrhoea and severe clinical signs. CPV was more prevalent in puppies under 3 months of age. Puppies from high-volume dog breeders were significantly at increased risk for CPV (OR 4.20), CCoV (OR 4.50) and Cystoisospora spp. (OR 3.60). CCoV occurred significantly more often in winter (OR 3.35), and CPV in winter (OR 3.78) and spring (OR 4.72) as compared to summer. We conclude that routine screening for CPV, CCoV and hEC is recommended in puppies with acute diarrhoea, especially if they are under 3 months of age and originate from high-volume dog breeders. Routine screening for other pathogens may lead to less conclusive results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Does time of day influence cancer detection and recall rates in mammography?

    NASA Astrophysics Data System (ADS)

    Stinton, Chris; Jenkinson, David; Adekanmbi, Victor; Clarke, Aileen; Taylor-Phillips, Sian

    2017-03-01

    Background: The interpretation of screening mammograms is influenced by factors such as reader experience and their annual interpretative volume. There is some evidence that time of day can also have an effect, with better diagnostic accuracy for readings conducted early in the day. This is not a consistent finding, however. The aim of our study is to provide further evidence on whether there is an effect of time of day on recall- and breast cancer detection rates. Method: We analysed breast screening data from 222,577 women from the Midlands of England. Data were split into three eight hour periods: 0900-1700, 1700-0100, 0100-0900. Differences in recall- and cancer detection rates were analysed using multilevel logistic regression models. Results: Recall rates were lowest for mammograms read between the 1700-0100 time period. Cancer detection rates were lowest during the 0100-0900 time period. Conclusions: Our findings suggest that there are fluctuations in recall- and cancer detection rates over the course of the day.

  3. Novel hits for acetylcholinesterase inhibition derived by docking-based screening on ZINC database.

    PubMed

    Doytchinova, Irini; Atanasova, Mariyana; Valkova, Iva; Stavrakov, Georgi; Philipova, Irena; Zhivkova, Zvetanka; Zheleva-Dimitrova, Dimitrina; Konstantinov, Spiro; Dimitrov, Ivan

    2018-12-01

    The inhibition of the enzyme acetylcholinesterase (AChE) increases the levels of the neurotransmitter acetylcholine and symptomatically improves the affected cognitive function. In the present study, we searched for novel AChE inhibitors by docking-based virtual screening of the standard lead-like set of ZINC database containing more than 6 million small molecules using GOLD software. The top 10 best-scored hits were tested in vitro for AChE affinity, neurotoxicity, GIT and BBB permeability. The main pharmacokinetic parameters like volume of distribution, free fraction in plasma, total clearance, and half-life were predicted by previously derived models. Nine of the compounds bind to the enzyme with affinities from 0.517 to 0.735 µM, eight of them are non-toxic. All hits permeate GIT and BBB and bind extensively to plasma proteins. Most of them are low-clearance compounds. In total, seven of the 10 hits are promising for further lead optimisation. These are structures with ZINC IDs: 00220177, 44455618, 66142300, 71804814, 72065926, 96007907, and 97159977.

  4. [Research of preparation craft of Danshen phenolic acid fast release unit in multi-drug delivery system of Tongmai micro-pellets].

    PubMed

    Chen, Bin; Xiao, Wei; Jia, Xiao-Bin; Huang, Yang

    2012-07-01

    To prepare Danshen phenolic acid fast release micro-pellets and study its preparation craft. The factors which could impact yield, extrude shaping, dissolution of Danshen phenolic acid micro-pellets such as wetting agent, drug loading dose, adjuvant, lactose dose, disintegrant, CMS-Na dose and wetting agent dose was investigated. The optimum preparation craft of Danshen phenolic acid fast release micro-pellets was screened out by orhogonal design. Formula of Danshen phenolic acid fast release micro-pellets was calculated as volume dose 50 g. The formula was as follows: principal agent 22.5 g, lactose 5 g, CMS-Na 2 g, MCC 20.5 g, 27 mL 30% ethanol as wetting agent. Extrusion-spheronization was applied. The optimum conditions were screened out as follows: extrusion frequency (25 Hz), spheronization machine frequency (50 Hz), spheronization time (4 min). The process was scientific and rational. The preparation is stable settles basis for multi-drug delivery system of Tongmai micro-pellets.

  5. Quantification of mammographic masking risk with volumetric breast density maps: how to select women for supplemental screening

    NASA Astrophysics Data System (ADS)

    Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.

  6. Kinetics of Diffusional Droplet Growth in a Liquid/Liquid Two-Phase System

    NASA Technical Reports Server (NTRS)

    Glicksman, M. E.; Fradkov, V. E.

    1996-01-01

    We address the problem of diffusional interactions in a finite sized cluster of spherical particles for volume fractions, V(sub v) in the range 0-0.01. We determined the quasi-static monopole diffusion solution for n particles distributed at random in a continuous matrix. A global mass conservation condition is employed, obviating the need for any external boundary condition. The numerical results provide the instantaneous (snapshot) growth or shrinkage rate of each particle, precluding the need for extensive time-dependent computations. The close connection between these snapshot results and the coarsegrained kinetic constants are discussed. A square-root dependence of the deviations of the rate constants from their zero volume fraction value is found for the higher V(sub v) investigated. This behavior is consistent with predictions from diffusion Debye-Huckel screening theory. By contrast, a cube-root dependence, reported in earlier numerical studies, is found for the lower V(sub v) investigated. The roll-over region of the volume fraction where the two asymptotics merge depends on the number of particles, n, alone. A theoretical estimate for the roll-over point predicts that the corresponding V(sub v) varies as n(sup -2), in good agreement with the numerical results.

  7. Toxicological assessment of green petroleum coke.

    PubMed

    McKee, Richard H; Herron, Deborah; Beatty, Patrick; Podhasky, Paula; Hoffman, Gary M; Swigert, James; Lee, Carol; Wong, Diana

    2014-01-01

    Green petroleum coke is primarily inorganic carbon with some entrained volatile hydrocarbon material. As part of the petroleum industry response to the high production volume challenge program, the potential for reproductive effects was assessed in a subchronic toxicity/reproductive toxicity screening test in rats (OECD 421). The repeated-dose portion of the study provided evidence for dust accumulation and inflammatory responses in rats exposed to 100 and 300 mg/m(3) but there were no effects at 30 mg/m(3). In the reproductive toxicity screen, the frequency of successful matings was reduced in the high exposure group (300 mg/m(3)) and was not significantly different from control values but was outside the historical experience of the laboratory. The postnatal observations (external macroscopic examination, body weight, and survival) did not indicate any treatment-related differences. Additional tests conducted to assess the potential hazards to aquatic (fish, invertebrates, and algae) and soil dwelling organisms (earthworms and vascular plants) showed few effects at the maximum loading rates of 1000 mg coke/L in aquatic studies and 1000 mg coke/kg soil in terrestrial studies. The only statistically significant finding was an inhibition of algal growth measured as either biomass or growth rate.

  8. Macrocyclic fragrance materials--a screening-level environmental assessment using chemical categorization.

    PubMed

    Salvito, Daniel; Lapczynski, Aurelia; Sachse-Vasquez, Christen; McIntosh, Colin; Calow, Peter; Greim, Helmut; Escher, Beate

    2011-09-01

    A screening-level aquatic environmental risk assessment for macrocyclic fragrance materials using a "group approach" is presented using data for 30 macrocyclic fragrance ingredients. In this group approach, conservative estimates of environmental exposure and ecotoxicological effects thresholds for compounds within two subgroups (15 macrocyclic ketones and 15 macrocyclic lactones/lactides) were used to estimate the aquatic ecological risk potential for these subgroups. It is reasonable to separate these fragrance materials into the two subgroups based on the likely metabolic pathway required for biodegradation and on expected different ecotoxicological modes of action. The current volumes of use for the macrocyclic ketones in both Europe and North America ranges from <1 (low kg quantities) to no greater than 50 metric tonnes in either region and for macrocyclic lactones/lactides the volume of use range for both regions is <1 to no greater than 1000 metric tonnes in any one region. Based on these regional tonnages, biodegradability of these two subgroups of materials, and minimal in stream dilution (3:1), the conservatively predicted exposure concentrations for macrocyclic ketones would range from <0.01 to 0.05 μg/L in Europe and from <0.01 to 0.03 μg/L in North America. For macrocyclic lactones/lactides, the concentration within the mixing zone would range from <0.01 to 0.7 μg/L in Europe and from <0.01 to 1.0 μg/L in North America. The PNECs derived for the macrocyclic ketones is 0.22 μg/L and for macrocyclic lactones/lactides is 2.7 μg/L. The results of this screening-level aquatic ecological risk assessment indicate that at their current tonnage, often referred to as volumes of use, macrocyclic fragrance materials in Europe and North America, pose a negligible risk to aquatic biota; with no PEC/PNEC ratio exceeding 1 for any material in any subgroup. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Long life assurance study for manned spacecraft long life hardware. Volume 3: Long life assurance studies of components

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The guidelines for selecting hardware to be used in manned spacecraft to obtain a five year operational lifetime without maintenance were developed. An analysis was conducted on the design, application, failure mechanisms, manufacturing processes and controls, screen and burn-in techniques, and quality control of hardware items. The equipment considered for evaluation include: (1) electric motors and bearings; (2) accelerometers; (3) gyroscopes and bearings; (4) compressors and pumps, (5) magnetic tape recorders; (6) plumbing components and tubing; (7) check valves; (8) pressure regulators and solenoid valves; (9) thermal control valves; (10) pressure vessels and positive expulsion devices; (11) nickel cadmium batteries; and (12) transducers.

  10. Unplanned 30-day hospital readmission as a quality measure in gynecologic oncology.

    PubMed

    Wilbur, MaryAnn B; Mannschreck, Diana B; Angarita, Ana M; Matsuno, Rayna K; Tanner, Edward J; Stone, Rebecca L; Levinson, Kimberly L; Temkin, Sarah M; Makary, Martin A; Leung, Curtis A; Deutschendorf, Amy; Pronovost, Peter J; Brown, Amy; Fader, Amanda N

    2016-12-01

    Thirty-day readmission is used as a quality measure for patient care and Medicare-based hospital reimbursement. The primary study objective was to describe the 30-day readmission rate to an academic gynecologic oncology service. Secondary objectives were to identify risk factors and costs related to readmission. This was a retrospective, concurrent cohort study of all surgical admissions to an academic, high volume gynecologic oncology service during a two-year period (2013-2014). Data were collected on patient demographics, medical comorbidities, psychosocial risk factors, and results from a hospital discharge screening survey. Mixed logistic regression was used to identify factors associated with 30-day readmission and costs of readmission were assessed. During the two-year study period, 1605 women underwent an index surgical admission. Among this population, a total of 177 readmissions (11.0%) in 135 unique patients occurred. In a surgical subpopulation with >1 night stay, a readmission rate of 20.9% was observed. The mean interval to readmission was 11.8days (SD 10.7) and mean length of readmission stay was 5.1days (SD 5.0). Factors associated with readmission included radical surgery for ovarian cancer (OR 2.87) or cervical cancer (OR 4.33), creation of an ostomy (OR 11.44), a Charlson score of ≥5 (OR 2.15), a language barrier (OR 3.36), a median household income in the lowest quartile (OR 6.49), and a positive discharge screen (OR 2.85). The mean cost per readmission was $25,416 (SD $26,736), with the highest costs associated with gastrointestinal complications at $32,432 (SD $32,148). The total readmission-related costs during the study period were $4,523,959. Readmissions to a high volume gynecologic oncology service were costly and related to radical surgery for ovarian and cervical cancer as well as to medical, socioeconomic and psychosocial patient variables. These data may inform interventional studies aimed at decreasing unplanned readmissions in gynecologic oncology surgical populations. Copyright © 2016. Published by Elsevier Inc.

  11. Examining the occurrence of residues of flunixin meglumine in cull dairy cows by use of the flunixin cull cow survey.

    PubMed

    Deyrup, Cynthia L; Southern, Kristal J; Cornett, Julie A; Shultz, Craig E; Cera, Deborah A

    2012-07-15

    To determine whether cull dairy cows with signs of certain clinical conditions, termed suspect, are more likely than healthy-appearing cull dairy cows to have violative concentrations of flunixin meglumine in their tissues at slaughter. Cross-sectional study. 961 cull dairy cows. Suspect cull dairy cows were selected from 21 beef slaughter establishments with a high production volume of dairy cows, and kidney and liver tissues were collected for screening. Kidney tissues were screened for antibiotics and sulfonamides with the fast antimicrobial screening test (FAST). Liver tissues were screened for flunixin meglumine with an ELISA, and quantitative analysis of ELISA-positive samples was performed with high-performance liquid chromatography. During the same time period, liver tissues from 251 healthy-appearing cull dairy cows were collected for the Food Safety and Inspection Service National Residue Program Scheduled Sampling Plan, but were screened only for flunixin meglumine. Of 710 suspect cull dairy cows, 50 (7.04%) had liver tissue flunixin concentrations higher than the flunixin tolerance concentration (0.125 ppm). Thirty-one of 168 (18.45%) FAST-positive and 19 of 542 (3.51%) FAST-negative suspect cull dairy cows had violative tissue flunixin concentrations. Two of the 251 (0.80%) healthy-appearing cull dairy cows had violative tissue flunixin concentrations. Suspect cull dairy cows, especially those that were also FAST positive, had a significantly higher incidence of violative tissue flunixin concentrations than healthy-appearing cull dairy cows at slaughter. Targeted sampling plans for flunixin meglumine in suspect dairy cows can help to support more efficient use of resources and further safeguard the nation's food supply.

  12. Factors influencing the decline in lung density in a Danish lung cancer screening cohort.

    PubMed

    Shaker, Saher B; Dirksen, Asger; Lo, Pechin; Skovgaard, Lene T; de Bruijne, Marleen; Pedersen, Jesper H

    2012-11-01

    Lung cancer screening trials provide an opportunity to study the natural history of emphysema by using computed tomography (CT) lung density as a surrogate parameter. In the Danish Lung Cancer Screening Trial, 2,052 participants were included. At screening rounds, smoking habits were recorded and spirometry was performed. CT lung density was measured as the volume-adjusted 15th percentile density (PD15). A mixed effects model was used with former smoking males with <30 pack-yrs and without airflow obstruction (AFO) at entry as a reference group. At study entry, 893 (44%) participants had AFO. For the reference group, PD15 was 72.6 g·L(-1) with an annual decline of -0.33 g·L(-1). Female sex and current smoking increased PD15 at baseline, 17.3 g·L(-1) (p<0.001) and 10 g·L(-1) (p<0.001), respectively; and both increased the annual decline in PD15 (female: -0.3 g·L(-1); current smoking: -0.4 g·L(-1)). The presence and severity of AFO was a strong predictor of low PD15 at baseline (Global Initiative for Chronic Obstructive Lung Disease (GOLD) I: -1.4 g·L(-1); GOLD II: -6.3 g·L(-1); GOLD III: -17 g·L(-1)) and of increased annual decline in PD15 (GOLD I: -0.2 g·L(-1); GOLD II: -0.5 g·L(-1); GOLD III: -0.5 g·L(-1)). Female sex, active smoking and the presence of AFO are associated with accelerated decline in lung density.

  13. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    PubMed

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  14. Water swallow screening test for patients after surgery for head and neck cancer: early identification of dysphagia, aspiration and limitations of oral intake.

    PubMed

    Hey, Christiane; Lange, Benjamin P; Eberle, Silvia; Zaretsky, Yevgen; Sader, Robert; Stöver, Timo; Wagenblast, Jens

    2013-09-01

    Patients with head and neck cancer (HNC) are at high risk for oropharyngeal dysphagia (OD) following surgical therapy. Early identification of OD can improve outcomes and reduce economic burden. This study aimed to evaluate the validity of a water screening test using increasing volumes postsurgically for patients with HNC (N=80) regarding the early identification of OD in general, and whether there is a need for further instrumental diagnostics to investigate the presence of aspiration as well as to determine the limitations of oral intake as defined by fiberoptic endoscopic evaluation of swallowing. OD in general was identified in 65%, with aspiration in 49%, silent aspiration in 21% and limitations of oral intake in 56%. Despite a good sensitivity, for aspiration of 100% and for limitations of oral intake of 97.8%, the presented water screening test did not satisfactorily predict either of these reference criteria due to its low positive likelihood ratio (aspiration=2.6; limitations of oral intake=3.1). However, it is an accurate tool for the early identification of OD in general, with a sensitivity of 96.2% and a positive likelihood ratio of 5.4 in patients after surgery for HNC.

  15. High Throughput, Polymeric Aqueous Two-Phase Printing of Tumor Spheroids

    PubMed Central

    Atefi, Ehsan; Lemmo, Stephanie; Fyffe, Darcy; Luker, Gary D.; Tavana, Hossein

    2014-01-01

    This paper presents a new 3D culture microtechnology for high throughput production of tumor spheroids and validates its utility for screening anti-cancer drugs. We use two immiscible polymeric aqueous solutions and microprint a submicroliter drop of the “patterning” phase containing cells into a bath of the “immersion” phase. Selecting proper formulations of biphasic systems using a panel of biocompatible polymers results in the formation of a round drop that confines cells to facilitate spontaneous formation of a spheroid without any external stimuli. Adapting this approach to robotic tools enables straightforward generation and maintenance of spheroids of well-defined size in standard microwell plates and biochemical analysis of spheroids in situ, which is not possible with existing techniques for spheroid culture. To enable high throughput screening, we establish a phase diagram to identify minimum cell densities within specific volumes of the patterning drop to result in a single spheroid. Spheroids show normal growth over long-term incubation and dose-dependent decrease in cellular viability when treated with drug compounds, but present significant resistance compared to monolayer cultures. The unprecedented ease of implementing this microtechnology and its robust performance will benefit high throughput studies of drug screening against cancer cells with physiologically-relevant 3D tumor models. PMID:25411577

  16. The erythrocyte osmotic resistance test as screening tool for cholesterol-related lysosomal storage diseases.

    PubMed

    López de Frutos, Laura; Cebolla, Jorge J; Irún, Pilar; Köhler, Ralf; Giraldo, Pilar

    2018-05-01

    Erythrocyte volume regulation and membrane elasticity are essential for adaptation to osmotic and mechanical stress, and life span. Here, we evaluated whether defective cholesterol trafficking caused by the rare lysosomal storages diseases (LSDs), Niemann-Pick type C (NPC) and Lysosomal acid lipase (LAL) deficiency (LALD) impairs these properties. Moreover, we tested whether measurements of cholesterol membrane content and osmotic resistance serve as a screening test for these LSDs. Patients were genotyped for mutations in NPC1, NPC2, or LIPA genes. We measured LSD plasma biomarkers and LAL activity. Red blood cells (RBC) membrane cholesterol content was evaluated in 73 subjects. Osmotic resistance tests (ORT) were conducted in 121 blood samples from LSD suspected patients and controls. We did not find statistically significant differences between RBC cholesterol content between subjects and controls. However, the ORT, particularly at 0.49% (w/v) hypotonic sodium chloride solution, revealed a significant higher osmotic resistance in LSDs patients than in controls. We established a cut-off value of ≤51% of haemolysis with sensibility and specificity values of 80% and 70%, respectively. NPC and LALD do not alter cholesterol content in the RBC membrane but increase osmotic resistance. Therefore, ORT serves as screening test for the studied LSDs. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Change descriptors for determining nodule malignancy in national lung screening trial CT screening images

    NASA Astrophysics Data System (ADS)

    Geiger, Benjamin; Hawkins, Samuel; Hall, Lawrence O.; Goldgof, Dmitry B.; Balagurunathan, Yoganand; Gatenby, Robert A.; Gillies, Robert J.

    2016-03-01

    Pulmonary nodules are effectively diagnosed in CT scans, but determining their malignancy has been a challenge. The rate of change of the volume of a pulmonary nodule is known to be a prognostic factor for cancer development. In this study, we propose that other changes in imaging characteristics are similarly informative. We examined the combination of image features across multiple CT scans, taken from the National Lung Screening Trial, with individual scans of the same patient separated by approximately one year. By subtracting the values of existing features in multiple scans for the same patient, we were able to improve the ability of existing classification algorithms to determine whether a nodule will become malignant. We trained each classifier on 83 nodules determined to be malignant by biopsy and 172 nodules determined to be benign by their clinical stability through two years of no change; classifiers were tested on 77 malignant and 144 benign nodules, using a set of features that in a test-retest experiment were shown to be stable. An accuracy of 83.71% and AUC of 0.814 were achieved with the Random Forests classifier on a subset of features determined to be stable via test-retest reproducibility analysis, further reduced with the Correlation-based Feature Selection algorithm.

  18. Developing a scalable model of recombinant protein yield from Pichia pastoris: the influence of culture conditions, biomass and induction regime

    PubMed Central

    Holmes, William J; Darby, Richard AJ; Wilks, Martin DB; Smith, Rodney; Bill, Roslyn M

    2009-01-01

    Background The optimisation and scale-up of process conditions leading to high yields of recombinant proteins is an enduring bottleneck in the post-genomic sciences. Typical experiments rely on varying selected parameters through repeated rounds of trial-and-error optimisation. To rationalise this, several groups have recently adopted the 'design of experiments' (DoE) approach frequently used in industry. Studies have focused on parameters such as medium composition, nutrient feed rates and induction of expression in shake flasks or bioreactors, as well as oxygen transfer rates in micro-well plates. In this study we wanted to generate a predictive model that described small-scale screens and to test its scalability to bioreactors. Results Here we demonstrate how the use of a DoE approach in a multi-well mini-bioreactor permitted the rapid establishment of high yielding production phase conditions that could be transferred to a 7 L bioreactor. Using green fluorescent protein secreted from Pichia pastoris, we derived a predictive model of protein yield as a function of the three most commonly-varied process parameters: temperature, pH and the percentage of dissolved oxygen in the culture medium. Importantly, when yield was normalised to culture volume and density, the model was scalable from mL to L working volumes. By increasing pre-induction biomass accumulation, model-predicted yields were further improved. Yield improvement was most significant, however, on varying the fed-batch induction regime to minimise methanol accumulation so that the productivity of the culture increased throughout the whole induction period. These findings suggest the importance of matching the rate of protein production with the host metabolism. Conclusion We demonstrate how a rational, stepwise approach to recombinant protein production screens can reduce process development time. PMID:19570229

  19. Bone architecture and strength in the growing skeleton: the role of sedentary time.

    PubMed

    Gabel, Leigh; McKay, Heather A; Nettlefold, Lindsay; Race, Douglas; Macdonald, Heather M

    2015-02-01

    Today's youths spend close to 60% of their waking hours in sedentary activities; however, we know little about the potentially deleterious effects of sedentary time on bone health during this key period of growth and development. Thus, our objective was to determine whether sedentary time is associated with bone architecture, mineral density, and strength in children, adolescents, and young adults. We used high-resolution peripheral quantitative computed tomography (Scanco Medical) to measure bone architecture (trabecular and cortical microstructure and bone macrostructure) and cortical and total bone mineral density (BMD) at the distal tibia (8% site) in 154 males and 174 females (9-20 yr) who were participants in the University of British Columbia Healthy Bones III study. We applied finite element analysis to high-resolution peripheral quantitative computed tomography scans to estimate bone strength. We assessed self-reported screen time in all participants using a questionnaire and sedentary time (volume and patterns) in a subsample of participants with valid accelerometry data (89 males and 117 females; ActiGraph GT1M). We fit sex-specific univariate multivariable regression models, controlling for muscle cross-sectional area, limb length, maturity, ethnicity, dietary calcium, and physical activity. We did not observe independent effect of screen time on bone architecture, BMD, or strength in either sex (P > 0.05). Likewise, when adjusted for muscle cross-sectional area, limb length, maturity, ethnicity, dietary calcium, and physical activity, accelerometry-derived volume of sedentary time and breaks in bouts of sedentary time were not a determinant of bone architecture, BMD, or strength in either sex (P > 0.05). Further study is warranted to determine whether the lack of association between sedentary time and bone architecture, BMD, and strength at the distal tibia is also present at other skeletal sites.

  20. The Power of Neuroimaging Biomarkers for Screening Frontotemporal Dementia

    PubMed Central

    McMillan, Corey T.; Avants, Brian B.; Cook, Philip; Ungar, Lyle; Trojanowski, John Q.; Grossman, Murray

    2014-01-01

    Frontotemporal dementia (FTD) is a clinically and pathologically heterogeneous neurodegenerative disease that can result from either frontotemporal lobar degeneration (FTLD) or Alzheimer’s disease (AD) pathology. It is critical to establish statistically powerful biomarkers that can achieve substantial cost-savings and increase feasibility of clinical trials. We assessed three broad categories of neuroimaging methods to screen underlying FTLD and AD pathology in a clinical FTD series: global measures (e.g., ventricular volume), anatomical volumes of interest (VOIs) (e.g., hippocampus) using a standard atlas, and data-driven VOIs using Eigenanatomy. We evaluated clinical FTD patients (N=93) with cerebrospinal fluid, gray matter (GM) MRI, and diffusion tensor imaging (DTI) to assess whether they had underlying FTLD or AD pathology. Linear regression was performed to identify the optimal VOIs for each method in a training dataset and then we evaluated classification sensitivity and specificity in an independent test cohort. Power was evaluated by calculating minimum sample sizes (mSS) required in the test classification analyses for each model. The data-driven VOI analysis using a multimodal combination of GM MRI and DTI achieved the greatest classification accuracy (89% SENSITIVE; 89% SPECIFIC) and required a lower minimum sample size (N=26) relative to anatomical VOI and global measures. We conclude that a data-driven VOI approach employing Eigenanatomy provides more accurate classification, benefits from increased statistical power in unseen datasets, and therefore provides a robust method for screening underlying pathology in FTD patients for entry into clinical trials. PMID:24687814

  1. Validation of a multilevel sampling device to determine the vertical variability of chlorinated solvent in a contaminated aquifer.

    PubMed

    Barnier, C; Palmier, C; Atteia, O

    2013-01-01

    The vertical heterogeneity of contaminant concentrations in aquifers is well known, but obtaining representative samples is still a subject of debate. In this paper, the question arises from sites where numerous fully screened wells exist and there is a need to define the vertical distribution of contaminants. For this purpose, several wells were investigated with different techniques on a site contaminated with chlorinated solvents. A core-bored well shows that a tetrachloroethene (PCE) phase is sitting on and infiltrating a less permeable layer. Downstream of the cored well, the following sampling techniques were compared on fully screened wells: low flow pumping at several depths, pumping between packers and a new multilevel sampler for fully screened wells. Concerning low flow rate pumping, very low gradients were found, which may be due to the existence of vertical flow inside the well or in the gravel pack. Sampling between packers gave results comparable with the cores, separating a layer with PCE and trichloroethene from another one with cis 1,2-dichloroethene and vinyl chloride as major compounds. Detailed sampling according to pumped volume shows that even between packers, cleaning of the inter-packer volume is necessary before each sampling. Lastly, the proposed new multilevel sampler gives results similar to the packers but has the advantages of much faster sampling and a constant vertical positioning, which is fairly important for long-term monitoring in highly stratified aquifers.

  2. Reliable nanomaterial classification of powders using the volume-specific surface area method

    NASA Astrophysics Data System (ADS)

    Wohlleben, Wendel; Mielke, Johannes; Bianchin, Alvise; Ghanem, Antoine; Freiberger, Harald; Rauscher, Hubert; Gemeinert, Marion; Hodoroaba, Vasile-Dan

    2017-02-01

    The volume-specific surface area (VSSA) of a particulate material is one of two apparently very different metrics recommended by the European Commission for a definition of "nanomaterial" for regulatory purposes: specifically, the VSSA metric may classify nanomaterials and non-nanomaterials differently than the median size in number metrics, depending on the chemical composition, size, polydispersity, shape, porosity, and aggregation of the particles in the powder. Here we evaluate the extent of agreement between classification by electron microscopy (EM) and classification by VSSA on a large set of diverse particulate substances that represent all the anticipated challenges except mixtures of different substances. EM and VSSA are determined in multiple labs to assess also the level of reproducibility. Based on the results obtained on highly characterized benchmark materials from the NanoDefine EU FP7 project, we derive a tiered screening strategy for the purpose of implementing the definition of nanomaterials. We finally apply the screening strategy to further industrial materials, which were classified correctly and left only borderline cases for EM. On platelet-shaped nanomaterials, VSSA is essential to prevent false-negative classification by EM. On porous materials, approaches involving extended adsorption isotherms prevent false positive classification by VSSA. We find no false negatives by VSSA, neither in Tier 1 nor in Tier 2, despite real-world industrial polydispersity and diverse composition, shape, and coatings. The VSSA screening strategy is recommended for inclusion in a technical guidance for the implementation of the definition.

  3. Exploiting PubChem for Virtual Screening

    PubMed Central

    Xie, Xiang-Qun

    2011-01-01

    Importance of the field PubChem is a public molecular information repository, a scientific showcase of the NIH Roadmap Initiative. The PubChem database holds over 27 million records of unique chemical structures of compounds (CID) derived from nearly 70 million substance depositions (SID), and contains more than 449,000 bioassay records with over thousands of in vitro biochemical and cell-based screening bioassays established, with targeting more than 7000 proteins and genes linking to over 1.8 million of substances. Areas covered in this review This review builds on recent PubChem-related computational chemistry research reported by other authors while providing readers with an overview of the PubChem database, focusing on its increasing role in cheminformatics, virtual screening and toxicity prediction modeling. What the reader will gain These publicly available datasets in PubChem provide great opportunities for scientists to perform cheminformatics and virtual screening research for computer-aided drug design. However, the high volume and complexity of the datasets, in particular the bioassay-associated false positives/negatives and highly imbalanced datasets in PubChem, also creates major challenges. Several approaches regarding the modeling of PubChem datasets and development of virtual screening models for bioactivity and toxicity predictions are also reviewed. Take home message Novel data-mining cheminformatics tools and virtual screening algorithms are being developed and used to retrieve, annotate and analyze the large-scale and highly complex PubChem biological screening data for drug design. PMID:21691435

  4. Screening for tuberculosis among adults newly diagnosed with HIV in sub-Saharan Africa: a cost-effectiveness analysis

    PubMed Central

    Zwerling, Alice A.; Sahu, Maitreyi; Ngwira, Lucky G.; Khundi, McEwen; Harawa, Tina; Corbett, Elizabeth L.; Chaisson, Richard E.; Dowdy, David W.

    2015-01-01

    Objective New tools, including light emitting diode (LED) fluorescence microscopy and the molecular assay Xpert MTB/RIF® offer increased sensitivity for TB in persons with HIV but come with higher costs. Using operational data from rural Malawi we explored the potential cost-effectiveness of on-demand screening for TB in low-income countries of sub-Saharan Africa. Design & Methods Costs were empirically collected in four clinics and one hospital using a micro-costing approach, through direct interview and observation from the national TB program perspective. Using decision analysis newly diagnosed persons with HIV were modeled as being screened by one of three strategies: Xpert, LED or standard of care (i.e., at the discretion of the treating physician). Results Cost-effectiveness of TB screening among persons newly diagnosed with HIV was largely determined by two factors: prevalence of active TB among patients newly diagnosed with HIV and volume of testing. In facilities screening at least 50 people with a 6.5% prevalence of TB, or at least 500 people with a 2.5% TB prevalence, screening with Xpert is likely to be cost-effective. At lower prevalence – including that observed in Malawi – LED microscopy may be the preferred strategy, whereas in settings of lower TB prevalence or small numbers of eligible patients, no screening may be reasonable (such that resources can be deployed elsewhere). Conclusions TB screening at the point of HIV diagnosis may be cost-effective in low-income countries of sub-Saharan Africa, but only if a relatively large population with high prevalence of TB can be identified for screening. PMID:26049281

  5. Comparative ultrasound measurement of normal thyroid gland dimensions in school aged children in our local environment.

    PubMed

    Marchie, T T; Oyobere, O; Eze, K C

    2012-01-01

    The objective of this study was to determine the measurement of normal range of ultrasound (US) thyroid gland dimensions in school-aged children (6-16 years) in our environment and compared with what is obtained elsewhere. A prospective ultrasound measurement study done in University of Benin Teaching Hospital Benin, Nigeria. A prospective ultrasound (US) study of thyroid dimensions of 500 school-aged children in our environment consisting of 227 boys and 273 girls was done from 1 December 2006 to July 2007. The subjects were examined by the authors and subjects with palpable abnormal thyroid gland were excluded from the study. The thyroid dimensions (length, height, and diameter) were taken for each lobe by means of ultrasound (US). In addition volume of each thyroid lobe was calculated and the summation of volume of the lobes was taken as thyroid gland volume of each subject. Also height and weight of patients were documented from which the subject's body surface was calculated. Incidental thyroid gland lesion in US was excluded from the study. Using the Statistical program of social science (SPSS) and INSTAT (Graph Pad Inc. USA) the data were analyzed. Informed consent was obtained from all the subjects and the study was done in line with the ethical guidelines of the centers. The US thyroid gland volume in school-aged children in Benin City from this study ranges between 1.17 cm 3 and 7.19 cm 3 , mean volume range of 1.76-4.95 cm 3 , median volume range of 1.73-4.73 cm 3 , and range of standard deviation from 0.39 cm 3 to 1.49 cm 3 . The average mean thyroid volume is 2.32 cm 3 with the following average dimensions; anteroposterior right lobe =1.06 cm, mediolateral right lobe = 1.01 cm and craniocaudal right lobe = 2.34 cm, and anteroposterior left lobe = 1.01 cm, mediolateral left lobe = 1.04 cm and craniocaudal left lobe = 2.41 cm for both boys and girls respectively. These data are significantly lower than data obtained by European based World Health Organization/International Council for the Control of Iodine Deficiency Disorders (WHO/ICCIDD) 1997. However there is significant similarity with data obtained in similar environment. Ultrasound thyroid gland dimensions in school-aged children in our environment are reproducible and the data obtained are comparable to those obtained in other environment. The values may be better used in our environment as reference data for screening purposes.

  6. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy.

    PubMed

    Ung, K A; White, R; Mathlum, M; Mak-Hau, V; Lynch, R

    2014-01-01

    In post-prostatectomy radiotherapy to the prostatic bed, consistent bladder volume is essential to maintain the position of treatment target volume. We assessed the differences between bladder volume readings from a portable bladder scanner (BS-V) and those obtained from planning CT (CT-V) or cone-beam CT (CBCT-V). Interfraction bladder volume variation was also determined. BS-V was recorded before and after planning CT or CBCT. The percentage differences between the readings using the two imaging modalities, standard deviations and 95% confidence intervals were determined. Data were analysed for the whole patient cohort and separately for the older BladderScan™ BVI3000 and newer BVI9400 model. Interfraction bladder volume variation was determined from the percentage difference between the CT-V and CBCT-V. Treatment duration, incorporating the time needed for BS and CBCT, was recorded. Fourteen patients were enrolled, producing 133 data sets for analysis. BS-V was taken using the BVI9400 in four patients (43 data sets). The mean BS-V was 253.2 mL, and the mean CT-V or CBCT-V was 199 cm(3). The mean percentage difference between the two modalities was 19.7% (SD 42.2; 95%CI 12.4 to 26.9). The BVI9400 model produced more consistent readings, with a mean percentage difference of -6.2% (SD 27.8; 95% CI -14.7 to -2.4%). The mean percentage difference between CT-V and CBCT-V was 31.3% (range -48% to 199.4%). Treatment duration from time of first BS reading to CBCT was, on average, 12 min (range 6-27). The BS produces bladder volume readings of an average 19.7% difference from CT-V or CBCT-V and can potentially be used to screen for large interfraction bladder volume variations in radiotherapy to prostatic bed. The observed interfraction bladder volume variation suggests the need to improve bladder volume consistency. Incorporating the BS into practice is feasible. © 2014 The Royal Australian and New Zealand College of Radiologists.

  7. Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring.

    PubMed

    Sodickson, Aaron; Warden, Graham I; Farkas, Cameron E; Ikuta, Ichiro; Prevedello, Luciano M; Andriole, Katherine P; Khorasani, Ramin

    2012-08-01

    To develop and validate an informatics toolkit that extracts anatomy-specific computed tomography (CT) radiation exposure metrics (volume CT dose index and dose-length product) from existing digital image archives through optical character recognition of CT dose report screen captures (dose screens) combined with Digital Imaging and Communications in Medicine attributes. This institutional review board-approved HIPAA-compliant study was performed in a large urban health care delivery network. Data were drawn from a random sample of CT encounters that occurred between 2000 and 2010; images from these encounters were contained within the enterprise image archive, which encompassed images obtained at an adult academic tertiary referral hospital and its affiliated sites, including a cancer center, a community hospital, and outpatient imaging centers, as well as images imported from other facilities. Software was validated by using 150 randomly selected encounters for each major CT scanner manufacturer, with outcome measures of dose screen retrieval rate (proportion of correctly located dose screens) and anatomic assignment precision (proportion of extracted exposure data with correctly assigned anatomic region, such as head, chest, or abdomen and pelvis). The 95% binomial confidence intervals (CIs) were calculated for discrete proportions, and CIs were derived from the standard error of the mean for continuous variables. After validation, the informatics toolkit was used to populate an exposure repository from a cohort of 54 549 CT encounters; of which 29 948 had available dose screens. Validation yielded a dose screen retrieval rate of 99% (597 of 605 CT encounters; 95% CI: 98%, 100%) and an anatomic assignment precision of 94% (summed DLP fraction correct 563 in 600 CT encounters; 95% CI: 92%, 96%). Patient safety applications of the resulting data repository include benchmarking between institutions, CT protocol quality control and optimization, and cumulative patient- and anatomy-specific radiation exposure monitoring. Large-scale anatomy-specific radiation exposure data repositories can be created with high fidelity from existing digital image archives by using open-source informatics tools.

  8. Screening organic chemicals in commerce for emissions in the context of environmental and human exposure.

    PubMed

    Breivik, Knut; Arnot, Jon A; Brown, Trevor N; McLachlan, Michael S; Wania, Frank

    2012-08-01

    Quantitative knowledge of organic chemical release into the environment is essential to understand and predict human exposure as well as to develop rational control strategies for any substances of concern. While significant efforts have been invested to characterize and screen organic chemicals for hazardous properties, relatively less effort has been directed toward estimating emissions and hence also risks. Here, a rapid throughput method to estimate emissions of discrete organic chemicals in commerce has been developed, applied and evaluated to support screening studies aimed at ranking and identifying chemicals of potential concern. The method builds upon information in the European Union Technical Guidance Document and utilizes information on quantities in commerce (production and/or import rates), chemical function (use patterns) and physical-chemical properties to estimate emissions to air, soil and water within the OECD for five stages of the chemical life-cycle. The method is applied to 16,029 discrete substances (identified by CAS numbers) from five national and international high production volume lists. As access to consistent input data remains fragmented or even impossible, particular attention is given to estimating, evaluating and discussing uncertainties in the resulting emission scenarios. The uncertainty for individual substances typically spans 3 to 4 orders of magnitude for this initial tier screening method. Information on uncertainties in emissions is useful as any screening or categorization methods which solely rely on threshold values are at risk of leading to a significant number of either false positives or false negatives. A limited evaluation of the screening method's estimates for a sub-set of about 100 substances, compared against independent and more detailed emission scenarios presented in various European Risk Assessment Reports, highlights that up-to-date and accurate information on quantities in commerce as well as a detailed breakdown on chemical function are critically needed for developing more realistic emission scenarios.

  9. Brownian dynamics simulations of polyelectrolyte adsorption in shear flow with hydrodynamic interaction

    NASA Astrophysics Data System (ADS)

    Hoda, Nazish; Kumar, Satish

    2007-12-01

    The adsorption of single polyelectrolyte molecules in shear flow is studied using Brownian dynamics simulations with hydrodynamic interaction (HI). Simulations are performed with bead-rod and bead-spring chains, and electrostatic interactions are incorporated through a screened Coulombic potential with excluded volume accounted for by the repulsive part of a Lennard-Jones potential. A correction to the Rotne-Prager-Yamakawa tensor is derived that accounts for the presence of a planar wall. The simulations show that migration away from an uncharged wall, which is due to bead-wall HI, is enhanced by increases in the strength of flow and intrachain electrostatic repulsion, consistent with kinetic theory predictions. When the wall and polyelectrolyte are oppositely charged, chain behavior depends on the strength of electrostatic screening. For strong screening, chains get depleted from a region close to the wall and the thickness of this depletion layer scales as N1/3Wi2/3 at high Wi, where N is the chain length and Wi is the Weissenberg number. At intermediate screening, bead-wall electrostatic attraction competes with bead-wall HI, and it is found that there is a critical Weissenberg number for desorption which scales as N-1/2κ-3(lB∣σq∣)3/2, where κ is the inverse screening length, lB is the Bjerrum length, σ is the surface charge density, and q is the bead charge. When the screening is weak, adsorbed chains are observed to align in the vorticity direction at low shear rates due to the effects of repulsive intramolecular interactions. At higher shear rates, the chains align in the flow direction. The simulation method and results of this work are expected to be useful for a number of applications in biophysics and materials science in which polyelectrolyte adsorption plays a key role.

  10. State Defense Force Journal. Volume 3, Issue 1, Fall 2007

    DTIC Science & Technology

    2007-01-01

    operations officer in planning for the employment of medical units and personnel; receiving and analyzing medical intelligence (i.e., syndromic ...PE Colonel (MD) Martin Hershkowitz Maryland Defense Force 10th Medical Regiment: Past, Present and Future..................................... 15...MDARNG Expanding Support Roles for 10th Medical Regiment: Pre and Post Health Screenings of National Guard Soldiers and Airmen

  11. SCREENING METHOD FOR NITROAROMATIC COMPOUNDS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND INFRARED SPECTROSCOPY. (R825343)

    EPA Science Inventory

    A new method is described for determining nitroaromatic compounds in water
    that combines solid-phase microextraction (SPME) and infrared (IR) spectroscopy. In this method, the compounds are extracted from a 250-mL volume of water into a small square (3.2 cm ? 3.2 cm ? 61.2...

  12. Screening Maritime Shipping Containers for Weapons of Mass Destruction

    DTIC Science & Technology

    2010-01-01

    for dangerous chemical, biological, radiological, nuclear , and explosives (CBRNE) materials to prevent their unlawful transpOitation into the United...techniques, and various sensor modalities within their respective size, weight, and power constraints. Shipping containers are natural repositories ...isolators. The environmental enclosure has sufficient volume to allow for multiple sensors as well as a truth collection station (Summa canisters

  13. Changes in Determining Gifted Eligibility for Underrepresented Students. Research Note. Volume 0802

    ERIC Educational Resources Information Center

    Froman, Terry

    2008-01-01

    There are a number of detailed requirements for gifted screening, referral and eligibility specified under State Board Rules and School Board Rules. In all of these areas, explicit mention is made of the Florida Comprehensive Assessment Test (FCAT) Norm Referenced Test (NRT) scores as being integral components. Due to budget considerations, the…

  14. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  15. High-throughput screening approaches and combinatorial development of biomaterials using microfluidics.

    PubMed

    Barata, David; van Blitterswijk, Clemens; Habibovic, Pamela

    2016-04-01

    From the first microfluidic devices used for analysis of single metabolic by-products to highly complex multicompartmental co-culture organ-on-chip platforms, efforts of many multidisciplinary teams around the world have been invested in overcoming the limitations of conventional research methods in the biomedical field. Close spatial and temporal control over fluids and physical parameters, integration of sensors for direct read-out as well as the possibility to increase throughput of screening through parallelization, multiplexing and automation are some of the advantages of microfluidic over conventional, 2D tissue culture in vitro systems. Moreover, small volumes and relatively small cell numbers used in experimental set-ups involving microfluidics, can potentially decrease research cost. On the other hand, these small volumes and numbers of cells also mean that many of the conventional molecular biology or biochemistry assays cannot be directly applied to experiments that are performed in microfluidic platforms. Development of different types of assays and evidence that such assays are indeed a suitable alternative to conventional ones is a step that needs to be taken in order to have microfluidics-based platforms fully adopted in biomedical research. In this review, rather than providing a comprehensive overview of the literature on microfluidics, we aim to discuss developments in the field of microfluidics that can aid advancement of biomedical research, with emphasis on the field of biomaterials. Three important topics will be discussed, being: screening, in particular high-throughput and combinatorial screening; mimicking of natural microenvironment ranging from 3D hydrogel-based cellular niches to organ-on-chip devices; and production of biomaterials with closely controlled properties. While important technical aspects of various platforms will be discussed, the focus is mainly on their applications, including the state-of-the-art, future perspectives and challenges. Microfluidics, being a technology characterized by the engineered manipulation of fluids at the submillimeter scale, offers some interesting tools that can advance biomedical research and development. Screening platforms based on microfluidic technologies that allow high-throughput and combinatorial screening may lead to breakthrough discoveries not only in basic research but also relevant to clinical application. This is further strengthened by the fact that reliability of such screens may improve, since microfluidic systems allow close mimicking of physiological conditions. Finally, microfluidic systems are also very promising as micro factories of a new generation of natural or synthetic biomaterials and constructs, with finely controlled properties. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Online versus paper-based screening for depression and anxiety in adults with cystic fibrosis in Ireland: a cross-sectional exploratory study.

    PubMed

    Cronly, Jennifer; Duff, Alistair J; Riekert, Kristin A; Perry, Ivan J; Fitzgerald, Anthony P; Horgan, Aine; Lehane, Elaine; Howe, Barbara; Ni Chroinin, Muireann; Savage, Eileen

    2018-01-21

    To compare online and paper-based screening for depression and anxiety in adults with cystic fibrosis (CF). Cross-sectional study in CF clinics in Ireland and through the Cystic Fibrosis Ireland online community. 160 adult patients aged 18 or above were recruited. Of these, 147 were included in the analysis; 83 online and 64 paper-based. The remaining 13 were excluded because of incomplete data. Depression and anxiety were measured using the Hospital Anxiety and Depression Scale (HADS). Data on pulmonary function (forced expiratory volume in 1 s %) and body mass index were self-reported based on clinical assessments. Sociodemographic data were collected. Compared with the paper-based participants, the online participants were more likely to be female (61.7% vs 48.4%), older (mean 32.2 vs 28.2 years) and were more likely to be married (32.5% vs 15.6%), living with their spouse or partner (42.5% vs 22.6%) and working either full time (33.7% vs 15.9%) or part time (30.1%vs 17.5%). The prevalence rates of elevated anxiety and depression were not significantly different (P=0.71 and P=0.56). HADS anxiety and depression scores were not statistically different between online (P=0.83) and paper-based (P=0.92) participants based on Mann-Whitney U test. A significant negative correlation was found between depression and pulmonary function (r=-0.39, P=0.01) and anxiety and pulmonary function (r=-0.36, P=0.02). Based on Cronbach's alpha, there were no statistically significant differences between the online and paper-based participants on the internal consistency of the HADS anxiety (P=0.073) and depression (P=0.378) scales. Our findings suggest that online and paper-based screening for depression and anxiety in adult patients with CF yield comparable findings on prevalence rates and scores, associations with health and internal consistency of subscales. This study highlights that online screening offers an alternative method to paper-based screening. Further research with a larger sample and assessment of measurement equivalence between online and paper based screening is needed to confirm our results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Screening study for evaluation of the potential for system 80+ to consume excess plutonium - Volume 1. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-04-30

    As part of the U.S. effort to evaluate technologies offering solutions for the safe disposal or utilization of surplus nuclear materials, the fiscal year 1993 Energy and Water Appropriations legislation provided the Department of Energy (DOE) the necessary funds to conduct multi-phased studies to determine the technical feasibility of using reactor technologies for the triple mission of burning weapons grade plutonium, producing tritium for the existing smaller weapons stockpile, and generating commercial electricity. DOE limited the studies to five advanced reactor designs. Among the technologies selected is the ABB-Combustion Engineering (ABB-CE) System 80+. The DOE study, currently in Phase ID,more » is proceeding with a more detailed evaluation of the design`s capability for plutonium disposition.« less

  18. Model-based impact and cost-effectiveness of cervical cancer prevention in the Extended Middle East and North Africa (EMENA).

    PubMed

    Kim, Jane J; Sharma, Monisha; O'Shea, Meredith; Sweet, Steven; Diaz, Mireia; Sancho-Garnier, Hélène; Seoud, Muhieddine

    2013-12-30

    To date, no studies have evaluated the cost-effectiveness of human papillomavirus (HPV) vaccination in countries in the Extended Middle East and North Africa (EMENA) region. We synthesized population and epidemiologic data for 20 EMENA countries using a model-based approach to estimate averted cervical cancer cases and deaths, disability-adjusted life years (DALYs) and cost-effectiveness ratios (I$ [international dollars] per DALY averted) associated with HPV vaccination of pre-adolescent girls. We utilized additional epidemiologic data from Algeria, Lebanon, and Turkey to evaluate select cervical cancer screening strategies either alone or in combination with vaccination. Results showed that pre-adolescent vaccination of five consecutive birth cohorts at 70% coverage has the potential to prevent over 180,000 cervical cancer cases. Cases averted varied by country, largely due to differences in cancer burden and population size; 69% of cases averted occurred in the three GAVI-eligible countries in EMENA. Despite the low cervical cancer incidence in EMENA, we found that HPV vaccination was cost-effective using a threshold of each country's gross domestic product per capita (a common metric for evaluating cost-effectiveness) in all but five countries at a cost per vaccinated girl of I$25 ($5 per dose). However, cost-effectiveness diminished with increasing vaccine cost; at a cost of I$200 per vaccinated girl, HPV vaccination was cost-effective in only five countries. When the cost per vaccinated girl exceeded I$50 in Lebanon and Turkey and I$150 in Algeria, screening alone was most attractive. We identified opportunities to improve upon current national screening guidelines, involving less frequent screening every 3-5 years. While pre-adolescent HPV vaccination promises to be a cost-effective strategy in most EMENA countries at low costs, decision makers will need to consider many other factors, such as affordability, acceptability, feasibility, and competing health priorities, when making decisions about cervical cancer prevention. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Extended Middle East and North Africa Region" Vaccine Volume 31, Supplement 6, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Positive FAST without hemoperitoneum due to fluid resuscitation in blunt trauma.

    PubMed

    Slutzman, Jonathan E; Arvold, Lisa A; Rempell, Joshua S; Stone, Michael B; Kimberly, Heidi H

    2014-10-01

    The focused assessment with sonography in trauma (FAST) examination is an important screening tool in the evaluation of blunt trauma patients. To describe a case of a hemodynamically unstable polytrauma patient with positive FAST due to fluid resuscitation after blunt trauma. We describe a case of a hemodynamically unstable polytrauma patient who underwent massive volume resuscitation prior to transfer from a community hospital to a trauma center. On arrival at the receiving institution, the FAST examination was positive for free intraperitoneal fluid, but no hemoperitoneum or significant intra-abdominal injuries were found during laparotomy. In this case, it is postulated that transudative intraperitoneal fluid secondary to massive volume resuscitation resulted in a positive FAST examination. This case highlights potential issues specific to resuscitated trauma patients with prolonged transport times. Further study is likely needed to assess what changes, if any, should be made in algorithms to address the effect of prior resuscitative efforts on the test characteristics of the FAST examination. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Non-destructive Detection of Screw Dislocations and the Corresponding Defects Nucleated from Them During SiC Epitaxial Growth and Their Effect on Device Characteristics

    NASA Astrophysics Data System (ADS)

    Das, H.; Sunkari, S.; Naas, H.

    2018-06-01

    In high-volume manufacturing of SiC power devices like Schottky barrier diodes and MOSFETs, especially with the high demands of high reliability applications like the automotive market, the issue of reliability needs to be tackled from multiple angles. It becomes important to isolate and eliminate failure mechanisms at the source rather than just rely on electrical tests. As we enter volume production on 150-mm substrates, an added layer of reliability and improved yield can be added if potential sources of defects are identified and removed. In this work, we present the non-destructive detection of a subset of screw dislocations in N+ doped substrates, trace the preferential nucleation of V-type epitaxial defects and stacking faults from these screw dislocations, and study their electrical effects on Schottky diodes. This enables the screening of highly defective substrates even before committing them to epitaxial growth.

  1. An approach to enhance self-compensation capability in paper-based devices for chemical sensing.

    PubMed

    Lo, Shih-Jie; Chen, Kuan-Hung; Yao, Da-Jeng

    2015-12-01

    This paper describes a simple design for increasing the tolerance of reagent dislocation on a paper-based platform using a combination of wax-treated paper and a vortex mixer. To date, massive budgetary funds are required in the biotechnological industry to develop new applications; a large part of that cost is attributable to the screening of specific chemical compounds. Here, we propose using a liquid-handling robot to automatically deposit selected reagents on a paper-based platform. We also present a preliminary concept approach for developing a reagent placing device with simple and inexpensive features. A defect of inaccuracy was observed between droplet location and test well location after viewing the performance of the liquid-handling robot on our paper-based platform. Because of dislocation error resulting from robotic reagent placement, we decided to apply an external, rotational force following droplet placement in order to compensate for the distance of reagent dislocation. Note, the largest distance of reagent dislocation was determined by examining the results of altering applied reagent volume, but not concentration, in volumes from 5 µL to 30 µL in a series of experiments. As a result of these experiments, we observed that dislocation was positively affected by an increase in applied volume. A colorimetric assay for nitrite detection was also performed to confirm the feasibility of this method. This work, we believe, can minimize the cost of chemical compound screening for the biotechnological industry. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Web-based alcohol screening and brief intervention for university students: a randomized trial.

    PubMed

    Kypri, Kypros; Vater, Tina; Bowe, Steven J; Saunders, John B; Cunningham, John A; Horton, Nicholas J; McCambridge, Jim

    2014-03-26

    Unhealthy alcohol use is a leading contributor to the global burden of disease, particularly among young people. Systematic reviews suggest efficacy of web-based alcohol screening and brief intervention and call for effectiveness trials in settings where it could be sustainably delivered. To evaluate a national web-based alcohol screening and brief intervention program. A multisite, double-blind, parallel-group, individually randomized trial was conducted at 7 New Zealand universities. In April and May of 2010, invitations containing hyperlinks to the Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) screening test were e-mailed to 14,991 students aged 17 to 24 years. Participants who screened positive (AUDIT-C score ≥4) were randomized to undergo screening alone or to 10 minutes of assessment and feedback (including comparisons with medical guidelines and peer norms) on alcohol expenditure, peak blood alcohol concentration, alcohol dependence, and access to help and information. A fully automated 5-month follow-up assessment was conducted that measured 6 primary outcomes: consumption per typical occasion, drinking frequency, volume of alcohol consumed, an academic problems score, and whether participants exceeded medical guidelines for acute harm (binge drinking) and chronic harm (heavy drinking). A Bonferroni-corrected significance threshold of .0083 was used to account for the 6 comparisons and a sensitivity analysis was used to assess possible attrition bias. Of 5135 students screened, 3422 scored 4 or greater and were randomized, and 83% were followed up. There was a significant effect on 1 of the 6 prespecified outcomes. Relative to control participants, those who received intervention consumed less alcohol per typical drinking occasion (median 4 drinks [interquartile range {IQR}, 2-8] vs 5 drinks [IQR 2-8]; rate ratio [RR], 0.93 [99.17% CI, 0.86-1.00]; P = .005) but not less often (RR, 0.95 [99.17% CI, 0.88-1.03]; P = .08) or less overall (RR, 0.95 [99.17% CI, 0.81-1.10]; P = .33). Academic problem scores were not lower (RR, 0.91 [99.17% CI, 0.76-1.08]; P = .14) and effects on the risks of binge drinking (odds ratio [OR], 0.84 [99.17% CI, 0.67-1.05]; P = .04) and heavy drinking (OR, 0.77 [99.17% CI, 0.56-1.05]; P = .03) were not significantly significant. In a sensitivity analysis accounting for attrition, the effect on alcohol per typical drinking occasion was no longer statistically significant. A national web-based alcohol screening and brief intervention program produced no significant reductions in the frequency or overall volume of drinking or academic problems. There remains a possibility of a small reduction in the amount of alcohol consumed per typical drinking occasion. anzctr.org.au Identifier: ACTRN12610000279022.

  3. Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions.

    PubMed

    Sawin, C F; Nicogossian, A E; Rummel, J A; Michel, E L

    1976-02-01

    Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

  4. Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions

    NASA Technical Reports Server (NTRS)

    Sawin, C. F.; Nicogossian, A. E.; Rummel, J. A.; Michel, E. L.

    1976-01-01

    Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

  5. Volumetric breast density evaluation by ultrasound tomography and magnetic resonance imaging: a preliminary comparative study

    NASA Astrophysics Data System (ADS)

    Myc, Lukasz; Duric, Neb; Littrup, Peter; Li, Cuiping; Ranger, Bryan; Lupinacci, Jessica; Schmidt, Steven; Rama, Olsi; Bey-Knight, Lisa

    2010-03-01

    Since a 1976 study by Wolfe, high breast density has gained recognition as a factor strongly correlating with an increased incidence of breast cancer. These observations have led to mammographic density being designated a "risk factor" for breast cancer. Clinically, the exclusive reliance on mammography for breast density measurement has forestalled the inclusion of breast density into statistical risk models. This exclusion has in large part been due to the ionizing radiation associated with the method. Additionally, the use of mammography as valid tool for measuring a three dimensional characteristic (breast density) has been criticized for its prima facie incongruity. These shortfalls have prompted MRI studies of breast density as an alternative three-dimensional method of assessing breast density. Although, MRI is safe and can be used to measure volumetric density, its cost has prohibited its use in screening. Here, we report that sound speed measurements using a prototype ultrasound tomography device have potential for use as surrogates for breast density measurement. Accordingly, we report a strong positive linear correlation between volume-averaged sound speed of the breast and percent glandular tissue volume as assessed by MR.

  6. Evolution of Local Microstructures: Spatial Instabilities of Coarsening Clusters

    NASA Technical Reports Server (NTRS)

    Frazier, Donald O.

    1999-01-01

    This work examines the diffusional growth of discrete phase particles dispersed within a matrix. Engineering materials are microstructurally heterogeneous, and the details of the microstructure determine how well that material performs in a given application. Critical to the development of designing multiphase microstructures with long-term stability is the process of Ostwald ripening. Ripening, or phase coarsening, is a diffusion-limited process which arises in polydisperse multiphase materials. Growth and dissolution occur because fluxes of solute, driven by chemical potential gradients at the interfaces of the dispersed phase material, depend on particle size. The kinetics of these processes are "competitive," dictating that larger particles grow at the expense of smaller ones, overall leading to an increase of the average particle size. The classical treatment of phase coarsening was done by Todes, Lifshitz, and Slyozov, (TLS) in the limit of zero volume fraction, V(sub v), of the dispersed phase. Since the publication of TLS theory there have been numerous investigations, many of which sought to describe the kinetic scaling behavior over a 0 range of volume fractions. Some studies in the literature report that the relative increase in coarsening rate at low (but not zero) volume fractions compared to that predicted by TLS is proportional to v(sub v)(exp 1/2), whereas others suggcest V(sub v)(exp 1/3). This issue has been resolved recently by simulation studies at low volume fractions in three dimensions by members of the Rensselaer/MSFC team. Our studies of ripening behavior using large-scale numerical simulations suggest that although there are different circumstances which can lead to either scaling law, the most important length scale at low volume fractions is the diffusional analog of the Debye screening length. The numerical simulations we employed exploit the use of a recently developed "snapshot" technique, and identifies the nature of the coarsening dynamics at various volume fractions. Preliminary results of numerical and experimental investigations, focused on the growth of finite particle clusters, provide important insight into the nature of the transition between the two scaling regimes. The companion microgravity experiment centers on the growth within finite particle clusters, and follows the temporal dynamics driving microstructural evolution, using holography.

  7. Six-year prevalence and incidence of diabetic retinopathy and cost-effectiveness of tele-ophthalmology in Manitoba.

    PubMed

    Kanjee, Raageen; Dookeran, Ravi I; Mathen, Mathen K; Stockl, Frank A; Leicht, Richard

    2017-11-01

    The purpose of this study was to evaluate the diabetic retinopathy (DR) tele-ophthalmology screening program in Manitoba to determine prevalence and incidence of DR, as well as to estimate the program's cost-effectiveness. Retrospective chart review. A total of 4676 patients with type 2 diabetes examined 9334 times from 2007 to 2013. Focused ophthalmic histories were recorded and examinations were performed by trained nurses, including visual acuities, intraocular pressure, and mydriatic 7 standard field stereoscopic fundus photography. Images were evaluated by retinal specialists according to the Early Treatment of Diabetic Retinopathy Study criteria. DR prevalence and incidence were then calculated during the study period. Cost-effectiveness was estimated by comparing the cost of running the tele-ophthalmology program compared with the cost of screening the same volume of patients in-office. The average prevalence of any DR in each year was 25.1%. The cumulative incidence of DR across 6 years was 17.1% (95% CI, 15.4%-18.7%). The average savings per tele-ophthalmology examination was $1007. DR is highly prevalent among the studied population. Tele-ophthalmology provides a cost-effective means of monitoring patients as well as identifying new or treatable disease. Copyright © 2017. Published by Elsevier Inc.

  8. High-throughput on-chip in vivo neural regeneration studies using femtosecond laser nano-surgery and microfluidics

    NASA Astrophysics Data System (ADS)

    Rohde, Christopher B.; Zeng, Fei; Gilleland, Cody; Samara, Chrysanthi; Yanik, Mehmet F.

    2009-02-01

    In recent years, the advantages of using small invertebrate animals as model systems for human disease have become increasingly apparent and have resulted in three Nobel Prizes in medicine or chemistry during the last six years for studies conducted on the nematode Caenorhabditis elegans (C. elegans). The availability of a wide array of species-specific genetic techniques, along with the transparency of the worm and its ability to grow in minute volumes make C. elegans an extremely powerful model organism. We present a suite of technologies for complex high-throughput whole-animal genetic and drug screens. We demonstrate a high-speed microfluidic sorter that can isolate and immobilize C. elegans in a well-defined geometry, an integrated chip containing individually addressable screening chambers for incubation and exposure of individual animals to biochemical compounds, and a device for delivery of compound libraries in standard multiwell plates to microfluidic devices. The immobilization stability obtained by these devices is comparable to that of chemical anesthesia and the immobilization process does not affect lifespan, progeny production, or other aspects of animal health. The high-stability enables the use of a variety of key optical techniques. We use this to demonstrate femtosecond-laser nanosurgery and three-dimensional multiphoton microscopy. Used alone or in various combinations these devices facilitate a variety of high-throughput assays using whole animals, including mutagenesis and RNAi and drug screens at subcellular resolution, as well as high-throughput high-precision manipulations such as femtosecond-laser nanosurgery for large-scale in vivo neural degeneration and regeneration studies.

  9. Use of dye to distinguish salt and protein crystals under microcrystallization conditions

    NASA Technical Reports Server (NTRS)

    Cosenza, Larry (Inventor); Gester, Thomas E. (Inventor); Bray, Terry L. (Inventor); DeLucas, Lawrence J. (Inventor); Hamrick, David T. (Inventor)

    2007-01-01

    An improved method of screening crystal growth conditions is provided wherein molecules are crystallized from solutions containing dyes. These dyes are selectively incorporated or associated with crystals of particular character thereby rendering crystals of particular character colored and improving detection of the dyed crystals. A preferred method involves use of dyes in protein solutions overlayed by oil. Use of oil allows the use of small volumes of solution and facilitates the screening of large numbers of crystallization conditions in arrays using automated devices that dispense appropriate solutions to generate crystallization trials, overlay crystallization trials with an oil, provide appropriate conditions conducive to crystallization and enhance detection of dyed (colored) or undyed (uncolored) crystals that result.

  10. Study of space shuttle EVA/IVA support requirements. Volume 2: EVA/IVA tasks, guidelines, and constraints definition

    NASA Technical Reports Server (NTRS)

    Webbon, B. W.; Copeland, R. J.; Wood, P. W., Jr.; Cox, R. L.

    1973-01-01

    The guidelines for EVA and IVA tasks to be performed on the space shuttle are defined. In deriving tasks, guidelines, and constraints, payloads were first identified from the mission model. Payload requirements, together with man and manipulator capabilities, vehicle characteristics and operation, and safety considerations led to a definition of candidate tasks. Guidelines and constraints were also established from these considerations. Scenarios were established, and screening criteria, such as commonality of EVA and IVA activities, were applied to derive representative planned and unplanned tasks. The whole spectrum of credible contingency situations with a potential requirement for EVA/IVA was analyzed.

  11. Effects of vane/blade ratio and spacing on fan noise, volume 1

    NASA Technical Reports Server (NTRS)

    Gliebe, P. R.; Kantola, R. A.

    1983-01-01

    The noise characteristics of a high-speed fan were studied. The experimental investigation was carried out on a 50.8 cm (20 in.) diameter scale model fan stage in an anechoic chamber with an inflow turbulence control screen installed. The forty-four blade rotor was tested with forty-eight vane and eighty-six vane stator rows, over a range of aixal rotor-stator spacings from 0.5 to 2.3 rotor tip chords. A two-dimensional strip theory model of rotor-stator interaction noise was employed to predict the measured tone power level trends, and good overall agreement with measured trends was obtained.

  12. Definition of experiments and instruments for a communication/navigation research laboratory. Volume 2: Experiment selection

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The selection and definition of candidate experiments and the associated experiment instrumentation requirements are described. Information is presented that addresses the following study objectives: (1) determine specific research and technology needs in the comm/nav field through a survey of the scientific/technical community; (2) develop manned low earth orbit space screening criteria and compile lists of potential candidate experiments; (3) in Blue Book format, define and describe selected candidate experiments in sufficient detail to develop laboratory configuration designs and layouts; and (4) develop experiment time phasing criteria and recommend a payload for sortie can/early laboratory missions.

  13. Environmental toxicology and risk assessment: Standardization of biomarkers for endocrine disruption and environmental assessment: Eighth volume. Special technical publication 1364

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henshel, D.S.; Black, M.C.; Harrass, M.C.

    1999-07-01

    This conference was held April 20--22, 1998 in Atlanta, Georgia. The purpose of this conference was to provide a multidisciplinary forum for exchange of state-of-the-art information on biological markers in toxicology and risk assessment, including endocrine disrupter screening assays. Attention is focused on the following: aquatic toxicology; behavioral toxicology; biochemical indicators; developmental indicators; endocrine indicators; biodegradation and fate of chemicals; quality assurance and quality control within laboratory and field studies; risk assessment and communication, and harmonization of standards development. Individual papers have been processed separately for inclusion in the appropriate data bases.

  14. Flow Cytometry: Impact On Early Drug Discovery

    PubMed Central

    Edwards, Bruce S.; Sklar, Larry A.

    2015-01-01

    Summary Modern flow cytometers can make optical measurements of 10 or more parameters per cell at tens-of-thousands of cells per second and over five orders of magnitude dynamic range. Although flow cytometry is used in most drug discovery stages, “sip-and-spit” sampling technology has restricted it to low sample throughput applications. The advent of HyperCyt sampling technology has recently made possible primary screening applications in which tens-of-thousands of compounds are analyzed per day. Target-multiplexing methodologies in combination with extended multi-parameter analyses enable profiling of lead candidates early in the discovery process, when the greatest numbers of candidates are available for evaluation. The ability to sample small volumes with negligible waste reduces reagent costs, compound usage and consumption of cells. Improved compound library formatting strategies can further extend primary screening opportunities when samples are scarce. Dozens of targets have been screened in 384- and 1536-well assay formats, predominantly in academic screening lab settings. In concert with commercial platform evolution and trending drug discovery strategies, HyperCyt-based systems are now finding their way into mainstream screening labs. Recent advances in flow-based imaging, mass spectrometry and parallel sample processing promise dramatically expanded single cell profiling capabilities to bolster systems level approaches to drug discovery. PMID:25805180

  15. CSBB-ConeExclusion, adapting structure based solution virtual screening to libraries on solid support.

    PubMed

    Shave, Steven; Auer, Manfred

    2013-12-23

    Combinatorial chemical libraries produced on solid support offer fast and cost-effective access to a large number of unique compounds. If such libraries are screened directly on-bead, the speed at which chemical space can be explored by chemists is much greater than that addressable using solution based synthesis and screening methods. Solution based screening has a large supporting body of software such as structure-based virtual screening tools which enable the prediction of protein-ligand complexes. Use of these techniques to predict the protein bound complexes of compounds synthesized on solid support neglects to take into account the conjugation site on the small molecule ligand. This may invalidate predicted binding modes, the linker may be clashing with protein atoms. We present CSBB-ConeExclusion, a methodology and computer program which provides a measure of the applicability of solution dockings to solid support. Output is given in the form of statistics for each docking pose, a unique 2D visualization method which can be used to determine applicability at a glance, and automatically generated PyMol scripts allowing visualization of protein atom incursion into a defined exclusion volume. CSBB-ConeExclusion is then exemplarically used to determine the optimum attachment point for a purine library targeting cyclin-dependent kinase 2 CDK2.

  16. [Audit system on quality of breast cancer diagnosis and treatment: results of quality indicators on screen-detected lesions in Italy, 2010].

    PubMed

    Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Bisanti, Luigi; Casella, Denise; Deandrea, Silvia; Delrio, Daria; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Mantellini, Paola; Naldoni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Ravaioli, Alessandra; Sedda, Maria Laura; Taffurelli, Mario; Cataliotti, Luigi; Segnan, Nereo

    2012-01-01

    This survey, conducted by the Italian breast screening network (GISMa), collects yearly individual data on diagnosis and treatment on about 50% of all screen-detected, operated lesions in Italy. The 2010 results show good overall quality and an improving trend over time. Critical issues were identified, including waiting times and compliance with the recommendations on not performing frozen section examination on small lesions. Preoperative diagnosis improved constantly over the years, but there is still a large variation between regions and programmes. For almost 90% of screen-detected invasive cancers the sentinel lymph node technique (SLN) was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN for ductal carcinoma in situ deserves further investigation. The detailed results have been distributed, also by means of a web data warehouse, to regional and local screening programmes in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. It should be assigned priority to the problem of waiting times. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.

  17. Automated 3D ultrasound elastography of the breast: a phantom validation study

    NASA Astrophysics Data System (ADS)

    Hendriks, Gijs A. G. M.; Holländer, Branislav; Menssen, Jan; Milkowski, Andy; Hansen, Hendrik H. G.; de Korte, Chris L.

    2016-04-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s-1) and by three protocols: Go-Go (pre- and post-volumes with identical start and end positions), Go-Return (similar to Go-Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go-Go protocol was shown to be superior with better strain image quality (CNRe and SNRe) than Go-Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go-Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go-Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to implement 3D ultrasound quasi-static elastography on an ABVS-like system and to reduce scan times within one breath-hold (~10 s) by plane-wave acquisitions.

  18. Cryogenic Propellant Management Device: Conceptual Design Study

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Merino, Fred; Schuster, John; Newton, Christopher

    2010-01-01

    Concepts of Propellant Management Devices (PMDs) were designed for lunar descent stage reaction control system (RCS) and lunar ascent stage (main and RCS propulsion) missions using liquid oxygen (LO2) and liquid methane (LCH4). Study ground rules set a maximum of 19 days from launch to lunar touchdown, and an additional 210 days on the lunar surface before liftoff. Two PMDs were conceptually designed for each of the descent stage RCS propellant tanks, and two designs for each of the ascent stage main propellant tanks. One of the two PMD types is a traditional partial four-screen channel device. The other type is a novel, expanding volume device which uses a stretched, flexing screen. It was found that several unique design features simplified the PMD designs. These features are (1) high propellant tank operating pressures, (2) aluminum tanks for propellant storage, and (3) stringent insulation requirements. Consequently, it was possible to treat LO2 and LCH4 as if they were equivalent to Earth-storable propellants because they would remain substantially subcooled during the lunar mission. In fact, prelaunch procedures are simplified with cryogens, because any trapped vapor will condense once the propellant tanks are pressurized in space.

  19. Volumetric mammographic density: heritability and association with breast cancer susceptibility loci.

    PubMed

    Brand, Judith S; Humphreys, Keith; Thompson, Deborah J; Li, Jingmei; Eriksson, Mikael; Hall, Per; Czene, Kamila

    2014-12-01

    Mammographic density is a strong heritable trait, but data on its genetic component are limited to area-based and qualitative measures. We studied the heritability of volumetric mammographic density ascertained by a fully-automated method and the association with breast cancer susceptibility loci. Heritability of volumetric mammographic density was estimated with a variance component model in a sib-pair sample (N pairs = 955) of a Swedish screening based cohort. Associations with 82 established breast cancer loci were assessed in an independent sample of the same cohort (N = 4025 unrelated women) using linear models, adjusting for age, body mass index, and menopausal status. All tests were two-sided, except for heritability analyses where one-sided tests were used. After multivariable adjustment, heritability estimates (standard error) for percent dense volume, absolute dense volume, and absolute nondense volume were 0.63 (0.06) and 0.43 (0.06) and 0.61 (0.06), respectively (all P < .001). Percent and absolute dense volume were associated with rs10995190 (ZNF365; P = 9.0 × 10(-6) and 8.9 × 10(-7), respectively) and rs9485372 (TAB2; P = 1.8 × 10(-5) and 1.8 × 10(-3), respectively). We also observed associations of rs9383938 (ESR1) and rs2046210 (ESR1) with the absolute dense volume (P = 2.6 × 10(-4) and 4.6 × 10(-4), respectively), and rs6001930 (MLK1) and rs17356907 (NTN4) with the absolute nondense volume (P = 6.7 × 10(-6) and 8.4 × 10(-5), respectively). Our results support the high heritability of mammographic density, though estimates are weaker for absolute than percent dense volume. We also demonstrate that the shared genetic component with breast cancer is not restricted to dense tissues only. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. [Target and non-target screening of volatile organic compounds in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry].

    PubMed

    Ma, Huilian; Jin, Jing; Li, Yun; Chen, Jiping

    2017-10-08

    A method of comprehensive screening of the target and non-target volatile organic compounds (VOCs) in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed. In this paper, two types of solid phase adsorption column were compared, and the Tenex SS TD Tube was selected. The analytes were enriched into the adsorption tube by constant flow sampling, and detected by TD-GC-MS in full scan mode. Target compounds were quantified by internal standard method, and the quantities of non-target compounds were calculated by response coefficient of toluene. The method detection limits (MDLs) for the 24 VOCs were 1.06 to 5.44 ng, and MDLs could also be expressed as 0.004 to 0.018 mg/m 3 assuming that the sampling volume was 300 mL. The average recoveries were in the range of 78.4% to 89.4% with the relative standard deviations (RSDs) of 3.9% to 14.4% ( n =7). The established analytical method was applied for the comprehensive screening of VOCs in a waste incineration power plant in Dalian city. Twenty-nine VOCs were identified. In these compounds, only five VOCs were the target compounds set in advance, which accounted for 26.7% of the total VOCs identified. Therefore, this study further proved the importance of screening non-target compounds in the analysis of VOCs in industrial exhaust gas, and has certain reference significance for the complete determination of VOCs distribution.

  1. Relationship between prostate-specific antigen and obesity in prostate cancer screening: analysis of a large cohort in Japan.

    PubMed

    Kubota, Yasuaki; Seike, Kensaku; Maeda, Shinichi; Shinohara, Yuka; Iwata, Masamitsu; Sugimoto, Norio

    2011-01-01

    Previous studies have shown that lower prostate-specific antigen (PSA) levels in obese men might decrease the sensitivity of prostate cancer screening, leading to delayed diagnosis and unfavorable prognosis. We examined whether the effect of obesity is important in prostate cancer screening of Japanese men, who have a low prevalence of obesity. We analyzed 19,294 male subjects from a large cohort of Toyota Motor Corporation (TMC) employees (aged > 50 years, serum PSA level ≤ 4.0 ng/mL) who underwent physical examinations from August 2006 to December 2009. The relationship between PSA level and obesity-related factors was analyzed by simple and multiple regression analysis. The relationships between six body mass index (BMI) categories, and PSA level and PSA mass (PSA concentration × plasma volume) were analyzed. PSA level decreased significantly with increasing BMI, but the coefficient of determination was very low. Mean PSA values decreased from 1.02 to 0.85 ng/mL as BMI increased from underweight (BMI <18.5) to morbidly obese (BMI >35). However, PSA mass peaked in the overweight category and was slightly reduced with increasing BMI. On multiple regression analysis, PSA level was influenced by age, diastolic blood pressure and high-density lipoprotein as well as BMI. We found an inverse but weak relationship between PSA level and BMI. Obesity seems to have very limited influence on prostate cancer screening in this population. Nonetheless, when considering indications for prostatic biopsy in obese men, we should be aware that the hemodilution effect might reduce PSA levels. © 2010 The Japanese Urological Association.

  2. Alleviating the reference standard dilemma using a systematic exact mass suspect screening approach with liquid chromatography-high resolution mass spectrometry.

    PubMed

    Moschet, Christoph; Piazzoli, Alessandro; Singer, Heinz; Hollender, Juliane

    2013-11-05

    In this study, the efficiency of a suspect screening strategy using liquid chromatography-high resolution mass spectrometry (LC-HRMS) without the prior purchase of reference standards was systematically optimized and evaluated for assessing the exposure of rarely investigated pesticides and their transformation products (TPs) in 76 surface water samples. Water-soluble and readily ionizable (electrospray ionization) substances, 185 in total, were selected from a list of all insecticides and fungicides registered in Switzerland and their major TPs. Initially, a solid phase extraction-LC-HRMS method was established using 45 known, persistent, and high sales volume pesticides. Seventy percent of these target substances had limit of quantitation (LOQ) < 5 ng L(-1). This compound set was then used to develop and optimize a HRMS suspect screening method using only the exact mass as a priori information. Thresholds for blank subtraction, peak area, peak shape, signal-to-noise, and isotopic pattern were applied to automatically filter the initially picked peaks. The success rate was 70%; false negatives mainly resulted from low intense peaks. The optimized approach was applied to the remaining 140 substances. Nineteen additional substances were detected in environmental samples, two TPs for the first time in the environment. Sixteen substances were confirmed with reference standards purchased subsequently, while three TP standards could be obtained from industry or other laboratories. Overall, this screening approach was fast and very successful and can easily be expanded to other micropollutant classes for which reference standards are not readily accessible such as TPs of household chemicals.

  3. Mutagenicity studies in a tyre plant: in-vitro activity of urine concentrates and rubber chemicals.

    PubMed

    Crebelli, R; Falcone, E; Aquilina, G; Carere, A; Paoletti, A; Fabri, G

    1984-01-01

    A possible occupational contribution to urinary mutagenicity was studied in a tyre plant, by assaying concentrates of urine from 72 workmen and 23 controls for their activity in the Ames test and microtitre fluctuation test. The results show that smoking habits but not occupation are related to the appearance of a detectable urinary mutagenicity in strain TA98. A possible synergistic effect of occupation was, however, observed among tyre builders who were smokers. Mutagenicity screening of 25 rubber chemicals, of major technological relevance and used in high volume in the workplace investigated, showed that three of them are weakly active in TA98 and TA100 (tetramethylthiuram disulfide) or TA98 alone (poly-p-dinitrosobenzene and mixed diaryl-p-phenylendiamines).

  4. ALIAS (Acquisition and Logistics Information and Analysis System) Maintenance and Expansion Guide. Volume 1.

    DTIC Science & Technology

    1984-10-31

    unauthorized inspection, and against whole- sale destruction by purging of its files. The usability of the data base (its "integrity") can be lost if required...screen *SMCUFS : NOLLIFOR SCARIOEE : SCNCLSE sINwU :- c~ri- E LUIMK :- $1TH4 IED~ DUml) WHILE IWINANOW MVDXFL VARIABLE %fldn=amGL(BALDISH8 AY ItuN

  5. 40 CFR 63.443 - Standards for the pulping system at kraft, soda, and semi-chemical processes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... furnace with a heat input capacity greater than or equal to 44 megawatts (150 million British thermal...) Each screen system; (iii) Each decker system; and (iv) Each weak liquor storage tank. (b) The owner or... concentration at the outlet of the thermal oxidizer to 20 parts per million or less by volume, corrected to 10...

  6. 77 FR 21065 - Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth Group of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... Substances Control Act (TSCA). The test rule would require manufacturers and processors to develop screening... in 40 CFR 799.5090(j) or 40 CFR 721.10228(a) of the proposed rule's regulatory text published in the... petroleum refineries. Processors of one or more of the subject chemical substances (NAICS codes 325 and...

  7. Voyager electronic parts radiation program, volume 1

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Martin, K. E.; Price, W. E.

    1977-01-01

    The Voyager spacecraft is subject to radiation from external natural space, from radioisotope thermoelectric generators and heater units, and from the internal environment where penetrating electrons generate surface ionization effects in semiconductor devices. Methods for radiation hardening and tests for radiation sensitivity are described. Results of characterization testing and sample screening of over 200 semiconductor devices in a radiation environment are summarized.

  8. Community biomass handbook. Volume I: thermal wood energy

    Treesearch

    D. Becker; E. Lowell; D. Bihn; R. Anderson; S. Taff

    2014-01-01

    This handbook and financial app is a guide to help communities quickly determine if biomass energy projects might work for them so that this option is not overlooked. Its purpose is as a screening tool designed to save significant time, resources, and investment by weeding out those wood energy projects that may never come to fruition from those that have a chance of...

  9. Analyst Performance Measures. Volume 3. Information Quality Tools for Persistent Surveillanec Data Sets

    DTIC Science & Technology

    2011-11-01

    September 2012 as 88ABW-2012-5092.    Quality expectations of the viewer; for example, film screened in a cinema versus a short clip watched on a...dimension of lightness or luminescence (L) and two color components “a” and “b” is called a LAB. The French Commission Internationale de L’éclairage LAB

  10. Emerging Concerns in Reading; Highlights of the 21st Annual Reading Conference of Lehigh University.

    ERIC Educational Resources Information Center

    Kender, Joseph P., Ed.

    Addressing the question, "How can we teach all educable children to read effectively?" the papers in the first part of this volume look at several topical concerns in reading: "On Relocating the Reading Program: Finding a Better Barn for Our Sacred Cow,""The Transitional Open Classroom,""A Computer Program for Initial Screening of Problem…

  11. Maximizing People Power in Schools: Motivating and Managing Teachers and Staff. Successful Schools: Guidebooks to Effective Educational Leadership. Volume 5.

    ERIC Educational Resources Information Center

    Frase, Larry E.

    Ways to motivate and manage teachers and staff are presented in this guidebook. Chapter 1 describes ways to staff a school and get it right the first time. Checklists for recruiting, screening, and hiring are included. Chapter 2 offers suggestions for operating successful teacher induction, professional development,and motivation programs to…

  12. Reduction of Thyroid Nodule Volume by Levothyroxine and Iodine Alone and in Combination: A Randomized, Placebo-Controlled Trial

    PubMed Central

    Reiners, C.; Paschke, R.; Wegscheider, K.

    2011-01-01

    Context: Nodular goiter is common worldwide, but there is still debate over the medical treatment. Objective: The objective of the study was the measurement of the effect of a treatment with (nonsuppressive) T4, iodine, or a combination of both compared with placebo on volume of thyroid nodules and thyroid. Design: This was a multicenter, randomized, double-blind trial in patients with nodular goiter in Germany [LISA (Levothyroxin und Iodid in der Strumatherapie Als Mono-oder Kombinationstherapie) trial]. Setting: The study was conducted in outpatient clinics in university hospitals and regional hospitals and private practices. Participants: One thousand twenty-four consecutively screened and centrally randomized euthyroid patients aged 18–65 yr with one or more thyroid nodules (minimal diameter 10 mm) participated in the study. Intervention: Intervention included placebo, iodine (I), T4, or T4+I for 1 yr. T4 doses were adapted for a TSH target range of 0.2–0.8 mU/liter. Outcome Measures: The primary end point was percent volume reduction of all nodules measured by ultrasound, and the main secondary end point was a change in goiter volume. Results: Nodule volume reductions were −17.3% [95% confidence interval (CI) −24.8/−9.0%, P < 0.001] in the T4+I group, −7.3% (95% CI −15.0/+1.2%, P = 0.201) in the T4 group, and −4.0% (95% CI −11.4/+4.2%, P = 0.328) in the I group as compared with placebo. In direct comparison, the T4+I therapy was significantly superior to T4 (P = 0.018) or I (P = 0.003). Thyroid volume reductions were −7.9% (95% CI −11.8/−3.9%, P < 0.001), −5.2% (95% CI −8.7/−1.6%, P = 0.024) and −2.5% (95% CI −6.2/+1.4%, P = 0.207), respectively. The T4+I therapy was significantly superior to I (P = 0.034) but not to T4 (P = 0.190). Conclusion: In a region with a sufficient iodine supply, a 1-yr therapy with a combination of I and T4 with incomplete suppression of thyrotropin reduced thyroid nodule volume further than either component alone or placebo. PMID:21715542

  13. Site characterization report for the basalt waste isolation project. Volume II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-11-01

    The reference location for a repository in basalt for the terminal storage of nuclear wastes on the Hanford Site and the candidate horizons within this reference repository location have been identified and the preliminary characterization work in support of the site screening process has been completed. Fifteen technical questions regarding the qualification of the site were identified to be addressed during the detailed site characterization phase of the US Department of Energy-National Waste Terminal Storage Program site selection process. Resolution of these questions will be provided in the final site characterization progress report, currently planned to be issued in 1987,more » and in the safety analysis report to be submitted with the License Application. The additional information needed to resolve these questions and the plans for obtaining the information have been identified. This Site Characterization Report documents the results of the site screening process, the preliminary site characterization data, the technical issues that need to be addressed, and the plans for resolving these issues. Volume 2 contains chapters 6 through 12: geochemistry; surface hydrology; climatology, meteorology, and air quality; environmental, land-use, and socioeconomic characteristics; repository design; waste package; and performance assessment.« less

  14. Operationalizing hippocampal volume as an enrichment biomarker for amnestic MCI trials: effect of algorithm, test-retest variability and cut-point on trial cost, duration and sample size

    PubMed Central

    Yu, P.; Sun, J.; Wolz, R.; Stephenson, D.; Brewer, J.; Fox, N.C.; Cole, P.E.; Jack, C.R.; Hill, D.L.G.; Schwarz, A.J.

    2014-01-01

    Objective To evaluate the effect of computational algorithm, measurement variability and cut-point on hippocampal volume (HCV)-based patient selection for clinical trials in mild cognitive impairment (MCI). Methods We used normal control and amnestic MCI subjects from ADNI-1 as normative reference and screening cohorts. We evaluated the enrichment performance of four widely-used hippocampal segmentation algorithms (FreeSurfer, HMAPS, LEAP and NeuroQuant) in terms of two-year changes in MMSE, ADAS-Cog and CDR-SB. We modeled the effect of algorithm, test-retest variability and cut-point on sample size, screen fail rates and trial cost and duration. Results HCV-based patient selection yielded not only reduced sample sizes (by ~40–60%) but also lower trial costs (by ~30–40%) across a wide range of cut-points. Overall, the dependence on the cut-point value was similar for the three clinical instruments considered. Conclusion These results provide a guide to the choice of HCV cut-point for aMCI clinical trials, allowing an informed trade-off between statistical and practical considerations. PMID:24211008

  15. Automated Gravimetric Calibration to Optimize the Accuracy and Precision of TECAN Freedom EVO Liquid Handler

    PubMed Central

    Bessemans, Laurent; Jully, Vanessa; de Raikem, Caroline; Albanese, Mathieu; Moniotte, Nicolas; Silversmet, Pascal; Lemoine, Dominique

    2016-01-01

    High-throughput screening technologies are increasingly integrated into the formulation development process of biopharmaceuticals. The performance of liquid handling systems is dependent on the ability to deliver accurate and precise volumes of specific reagents to ensure process quality. We have developed an automated gravimetric calibration procedure to adjust the accuracy and evaluate the precision of the TECAN Freedom EVO liquid handling system. Volumes from 3 to 900 µL using calibrated syringes and fixed tips were evaluated with various solutions, including aluminum hydroxide and phosphate adjuvants, β-casein, sucrose, sodium chloride, and phosphate-buffered saline. The methodology to set up liquid class pipetting parameters for each solution was to split the process in three steps: (1) screening of predefined liquid class, including different pipetting parameters; (2) adjustment of accuracy parameters based on a calibration curve; and (3) confirmation of the adjustment. The run of appropriate pipetting scripts, data acquisition, and reports until the creation of a new liquid class in EVOware was fully automated. The calibration and confirmation of the robotic system was simple, efficient, and precise and could accelerate data acquisition for a wide range of biopharmaceutical applications. PMID:26905719

  16. A Tabletop Persistent-Mode, Liquid-Helium-Free, 1.5-T/90-mm MgB2 “Finger” MRI Magnet for Osteoporosis Screening: Two Design Options

    PubMed Central

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C.; Iwasa, Yukikazu

    2017-01-01

    In this paper we present two design options for a tabletop liquid-helium-free, persistent-mode 1.5-T/90-mm MgB2 “finger” MRI magnet for osteoporosis screening. Both designs, one with and the other without an iron yoke, satisfy the following criteria: 1) 1.5-T center field with a 90-mm room-temperature bore for a finger to be placed at the magnet center; 2) spatial field homogeneity of <5 ppm over a 20-mm diameter of spherical volume (DSV); 3) persistent-mode operation with temporal stability of <0.1 ppm/hr; 4) liquid-helium-free operation; 5) 5-gauss fringe field radius of <50 cm from the magnet center; and 6) small and light enough for placement on an exam table. Although the magnet is designed to operate nominally at 10 K, maintained by a cryocooler, it has a 5-K temperature margin to keep its 1.5-T persistent field up to 15 K. The magnet will be immersed in a volume of solid nitrogen (SN2) that provides additional thermal mass when the cryocooler is switched off to provide a vibration-free measurement environment. The SN2 enables the magnet to maintain its persistent field over a period of time sufficient for quiescent measurement, while still limiting the magnet operating temperature to ≤15 K. We discuss first pros and cons of each design, and then further studies of our proposed MgB2 finger MRI magnet. PMID:29456437

  17. A Tabletop Persistent-Mode, Liquid-Helium-Free, 1.5-T/90-mm MgB2 "Finger" MRI Magnet for Osteoporosis Screening: Two Design Options.

    PubMed

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C; Iwasa, Yukikazu

    2018-04-01

    In this paper we present two design options for a tabletop liquid-helium-free, persistent-mode 1.5-T/90-mm MgB 2 "finger" MRI magnet for osteoporosis screening. Both designs, one with and the other without an iron yoke, satisfy the following criteria: 1) 1.5-T center field with a 90-mm room-temperature bore for a finger to be placed at the magnet center; 2) spatial field homogeneity of <5 ppm over a 20-mm diameter of spherical volume (DSV); 3) persistent-mode operation with temporal stability of <0.1 ppm/hr; 4) liquid-helium-free operation; 5) 5-gauss fringe field radius of <50 cm from the magnet center; and 6) small and light enough for placement on an exam table. Although the magnet is designed to operate nominally at 10 K, maintained by a cryocooler, it has a 5-K temperature margin to keep its 1.5-T persistent field up to 15 K. The magnet will be immersed in a volume of solid nitrogen (SN 2 ) that provides additional thermal mass when the cryocooler is switched off to provide a vibration-free measurement environment. The SN 2 enables the magnet to maintain its persistent field over a period of time sufficient for quiescent measurement, while still limiting the magnet operating temperature to ≤15 K. We discuss first pros and cons of each design, and then further studies of our proposed MgB 2 finger MRI magnet.

  18. Optimised cord blood sample selection for small‑scale CD34+ cell immunomagnetic isolation.

    PubMed

    Perdomo-Arciniegas, Ana-María; Vernot, Jean-Paul

    2012-03-01

    Haematopoietic stem cells (HSCs) are defined as multipotential cells, capable of self-renewal and reconstituting in vivo the haematopoietic compartment. The CD34 antigen is considered an important HSCs marker in humans. Immunomagnetic isolation, by targeting CD34 antigen, is widely used for human HSC separation. This method allows the enrichment of human HSCs that are present at low frequencies in umbilical cord blood (CB). Immunomagnetic CD34+-cell isolation reproducibility, regarding cell yield and purity, is affected by the CD34+ cell frequency and total cell numbers present in a given sample; CB HSC purification may thus yield variable results, which also depend on the volume and density fractionation-derived cell loss of a CB sample. The uncertainty of such an outcome and associated technical costs call for a cost-effective sample screening strategy. A correlation analysis using clinical and laboratory data from 59 CB samples was performed to establish predictive variables for CD34+-immunomagnetic HSCs isolation. This study described the positive association of CD34+-cell isolation with white and red cell numbers present after cell fractionation. Furthermore, purity has been correlated with lymphocyte percentages. Predictive variable cut-off values, which are particularly useful in situations involving low CB volumes being collected (such as prevalent late umbilical cord clamping clinical practice), were proposed for HSC isolation sampling. Using the simple and cost-effective CB sample screening criteria described here would lead to avoiding costly inefficient sample purification, thereby ensuring that pure CD34+ cells are obtained in the desired numbers following CD34 immunomagnetic isolation.

  19. International normalized ratio testing with a point-of-care coagulometer in 1-month-old infants: A comparison with Normotest.

    PubMed

    Iijima, Shigeo; Baba, Toru; Ueno, Daizo; Ohishi, Akira

    2016-09-01

    Early infants are at risk of vitamin K (VK) deficiency-associated bleeding unless they receive VK prophylaxis. A coagulation screening test might be necessary to detect prophylactic failure, but it is rarely conducted owing to the difficulty of blood sampling. CoaguChek XS is a portable, point-of-care (POC) coagulation analyzer that determines international normalized ratios (INRs) using only small volumes of blood. Although POC tests assessing INR have become widespread for adults, studies have not been performed in early infancy. This study aimed to determine the reference interval (RI) for INR for 1-month-old infants using the CoaguChek XS and to compare INRs with Normotest (NT) values to evaluate its efficacy as a VK deficiency screening test. This study included 578 consecutive 1-month-old, healthy, term infants who underwent a 1-month health checkup. CoaguChek XS INRs and NT values were analyzed for each subject. The enrolled neonates were orally administered VK 6-12h and 4days after birth. An INR RI for 1-month-old infants was established using the CoaguChek XS (range of 0.9-1.1). On the other hand, the NT RI was 69%-130%. We observed a significant inverse correlation between INRs and NT values. Our study is the first to establish an INR RI using the CoaguChek XS for 1-month-old, healthy, term infants. CoaguChek XS INR was more convenient to test than NT. However, we could not demonstrate its efficacy as a VK deficiency screening test because no infant had an aberrant NT value or a bleeding disorder. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Haematological and electrophoretic characterisation of β-thalassaemia in Yunnan province of Southwestern China

    PubMed Central

    Zhang, Jie; He, Jing; Mao, Xiaoqin; Zeng, Xiaohong; Chen, Hong; Su, Jie; Zhu, Baosheng

    2017-01-01

    Objectives β-Thalassaemia is widely found in Southwestern China. Characterisation of β-thalassaemia can improve screening and prenatal diagnosis for at-risk populations. Design A retrospective study. Methods In this study, the levels of haemoglobin alpha 2 (HbA2) and haemoglobin alpha (HbA) were analysed by gender for a total of 15 067 subjects screened by capillary electrophoresis. The cut-off value with the highest accuracy was established to identify β-thalassaemia in 723 patients suspected to have this disease. Haematological and electrophoretic characterisation of eight common types of β-thalassaemia were analysed in 486 β-thalassaemia subjects. Results HbA levels were significantly higher in men than in women, but there was no significant difference on HbA2 levels. A new cut-off value for the diagnosis of β-thalassaemia (HbA2≥4.0%) with the highest accuracy was proposed for the studied populations. Haemoglobin (Hb) was significantly higher in men compared with women (p<0.05), whereas no statistically significant differences were found for mean cell volume (MCV), mean cell haemoglobin (MCH), HbA and HbA2. The haemoglobin E (HbE) group showed comparatively higher values for haematological indices (Hb, MCV and MCH) than the other genotypes in heterozygous β-thalassaemia groups (p<0.05), and −28 (A>G) (HBB (β-globin):c.−78A>C) had significantly higher HbA2 values compared with other β-thalassaemia. Conclusions Ethnic groups have diversified β-globin gene mutations and considerable haematological variations. Our study will lay the foundation for screening programmes and clinical management of thalassaemia in Southwestern China. PMID:28143837

  1. Haematological and electrophoretic characterisation of β-thalassaemia in Yunnan province of Southwestern China.

    PubMed

    Zhang, Jie; He, Jing; Mao, Xiaoqin; Zeng, Xiaohong; Chen, Hong; Su, Jie; Zhu, Baosheng

    2017-01-31

    β-Thalassaemia is widely found in Southwestern China. Characterisation of β-thalassaemia can improve screening and prenatal diagnosis for at-risk populations. A retrospective study. In this study, the levels of haemoglobin alpha 2 (HbA 2 ) and haemoglobin alpha (HbA) were analysed by gender for a total of 15 067 subjects screened by capillary electrophoresis. The cut-off value with the highest accuracy was established to identify β-thalassaemia in 723 patients suspected to have this disease. Haematological and electrophoretic characterisation of eight common types of β-thalassaemia were analysed in 486 β-thalassaemia subjects. HbA levels were significantly higher in men than in women, but there was no significant difference on HbA 2 levels. A new cut-off value for the diagnosis of β-thalassaemia (HbA 2 ≥4.0%) with the highest accuracy was proposed for the studied populations. Haemoglobin (Hb) was significantly higher in men compared with women (p<0.05), whereas no statistically significant differences were found for mean cell volume (MCV), mean cell haemoglobin (MCH), HbA and HbA 2 . The haemoglobin E (HbE) group showed comparatively higher values for haematological indices (Hb, MCV and MCH) than the other genotypes in heterozygous β-thalassaemia groups (p<0.05), and -28 (A>G) (HBB (β-globin):c.-78A>C) had significantly higher HbA 2 values compared with other β-thalassaemia. Ethnic groups have diversified β-globin gene mutations and considerable haematological variations. Our study will lay the foundation for screening programmes and clinical management of thalassaemia in Southwestern China. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Rapid CO breath test screening of drugs for protective effects on ribavirin-induced hemolysis in a rabbit model: a pilot study.

    PubMed

    Ma, Yong-Jian; Zhang, Hou-De; Wu, Chuang-Hong; Zhu, Guo-Liang; Ji, Yong-Qiang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Ji, Kun-Mei

    2016-08-10

    Hemolytic anemia is a major side effect of ribavirin antiviral treatment for chronic hepatitis C. Ribavirin dose reduction may compromise the antiviral response and erythropoietin can take several weeks to alleviate anemia. The purpose of the present study was to screen potentially protective drugs against ribavirin-induced hemolytic anemia in a rabbit model, using our modified CO breath test for measuring erythrocyte (RBC) lifespan, the gold standard diagnostic index of hemolysis. Fifteen rabbits were divided randomly into five groups (N  =  3/group): one vehicle control group, one ribavirin (only)-treated (RBV) group, and three groups initially treated with ribavirin only, followed by a combination of ribavirin with prednisone (RBV  +  Pred), polyene phosphatidyl choline (RBV  +  PPC), or reduced glutathione (RBV  +  GSH). RBC lifespan was calculated from accumulated CO measured in a closed rebreath apparatus, blood volume measured by the Evan's blue dye (EBD) dilution test, and hemoglobin concentration data. The RBC lifespan was normal in the vehicle control group (44-60 d), but reduced significantly in all of the ribavirin-treated groups before the addition of screened drugs (17-35 d). RBC lifespan rebounded significantly with the addition of glutathione, but not with the addition of prednisone or polyene phosphatidyl choline. A similar overall drug effect pattern was seen in the hemoglobin concentration and reticulocyte count data. In conclusion, the results of this pilot study indicate that reduced glutathione can attenuate ribavirin-induced hemolytic anemia, and that the RBC lifespan measured with our modified rapid CO breath test is feasible and reliable for use in animal studies.

  3. Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning.

    PubMed

    Looney, Pádraig; Stevenson, Gordon N; Nicolaides, Kypros H; Plasencia, Walter; Molloholli, Malid; Natsis, Stavros; Collins, Sally L

    2018-06-07

    We present a new technique to fully automate the segmentation of an organ from 3D ultrasound (3D-US) volumes, using the placenta as the target organ. Image analysis tools to estimate organ volume do exist but are too time consuming and operator dependant. Fully automating the segmentation process would potentially allow the use of placental volume to screen for increased risk of pregnancy complications. The placenta was segmented from 2,393 first trimester 3D-US volumes using a semiautomated technique. This was quality controlled by three operators to produce the "ground-truth" data set. A fully convolutional neural network (OxNNet) was trained using this ground-truth data set to automatically segment the placenta. OxNNet delivered state-of-the-art automatic segmentation. The effect of training set size on the performance of OxNNet demonstrated the need for large data sets. The clinical utility of placental volume was tested by looking at predictions of small-for-gestational-age babies at term. The receiver-operating characteristics curves demonstrated almost identical results between OxNNet and the ground-truth). Our results demonstrated good similarity to the ground-truth and almost identical clinical results for the prediction of SGA.

  4. MACULAR CHOROIDAL VOLUME CHANGES AFTER INTRAVITREAL BEVACIZUMAB FOR EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    PubMed

    Palkovits, Stefan; Seidel, Gerald; Pertl, Laura; Malle, Eva M; Hausberger, Silke; Makk, Johanna; Singer, Christoph; Osterholt, Julia; Herzog, Sereina A; Haas, Anton; Weger, Martin

    2017-12-01

    To evaluate the effect of intravitreal bevacizumab on the macular choroidal volume and the subfoveal choroidal thickness in treatment naïve eyes with exudative age-related macular degeneration. The macular choroidal volume and the subfoveal choroidal thickness were measured using enhanced depth imaging optical coherence tomography. After a screening examination, each patient received 3 monthly intravitreal injections of 1.25 mg bevacizumab. One month after the third injection was a final assessment. Forty-seven patients with a mean age of 80 ± 6.4 years were included. The macular choroidal volume decreased significantly from median 4.1 mm (interquartile range 3.4-5.9) to median 3.9 mm (interquartile range 3.1-5.6) between the baseline and final examination (difference -0.46 mm, 95% confidence interval: -0.57 to 0.35, P < 0.001). Similarly, subfoveal choroidal thickness had decreased from 157.0 μm (interquartile range 116.0-244.5) at baseline to 139.0 μm (interquartile range 102.5-212.0) at the final examination (P < 0.001). Both parameters macular choroidal volume at baseline and subfoveal choroidal thickness at baseline were not associated with the response to treatment. The macular choroidal volume and the subfoveal choroidal thickness decreased significantly after 3 monthly bevacizumab injections for exudative age-related macular degeneration.

  5. The role of Area 10 (BA10) in human multitasking and in social cognition: a lesion study.

    PubMed

    Roca, María; Torralva, Teresa; Gleichgerrcht, Ezequiel; Woolgar, Alexandra; Thompson, Russell; Duncan, John; Manes, Facundo

    2011-11-01

    A role for rostral prefrontal cortex (BA10) has been proposed in multitasking, in particular, the selection and maintenance of higher order internal goals while other sub-goals are being performed. BA10 has also been implicated in the ability to infer someone else's feelings and thoughts, often referred to as theory of mind. While most of the data to support these views come from functional neuroimaging studies, lesion studies are scant. In the present study, we compared the performance of a group of frontal patients whose lesions involved BA10, a group of frontal patients whose lesions did not affect this area (nonBA10), and a group of healthy controls on tests requiring multitasking and complex theory of mind judgments. Only the group with lesions involving BA10 showed deficits on multitasking and theory of mind tasks when compared with control subjects. NonBA10 patients performed more poorly than controls on an executive function screening tool, particularly on measures of response inhibition and abstract reasoning, suggesting that theory of mind and multitasking deficits following lesions to BA10 cannot be explained by a general worsening of executive function. In addition, we searched for correlations between performance and volume of damage within different subregions of BA10. Significant correlations were found between multitasking performance and volume of damage in right lateral BA10, and between theory of mind and total BA10 lesion volume. These findings stress the potential pivotal role of BA10 in higher order cognitive functions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Screening for lung cancer: Does MRI have a role?

    PubMed

    Biederer, Juergen; Ohno, Yoshiharu; Hatabu, Hiroto; Schiebler, Mark L; van Beek, Edwin J R; Vogel-Claussen, Jens; Kauczor, Hans-Ulrich

    2017-01-01

    While the inauguration of national low dose computed tomographic (LDCT) lung cancer screening programs has started in the USA, other countries remain undecided, awaiting the results of ongoing trials. The continuous technical development achieved by stronger gradients, parallel imaging and shorter echo time has made lung magnetic resonance imaging (MRI) an interesting alternative to CT. For the detection of solid lesions with lung MRI, experimental and clinical studies have shown a threshold size of 3-4mm for nodules, with detection rates of 60-90% for lesions of 5-8mm and close to 100% for lesions of 8mm or larger. From experimental work, the sensitivity for infiltrative, non-solid lesions would be expected to be similarly high as that for solid lesions, but the published data for the MRI detection of lepidic growth type adenocarcinoma is sparse. Moreover, biological features such as a longer T2 time of lung cancer tissue, tissue compliance and a more rapid uptake of contrast material compared to granulomatous diseases, in principle should allow for the multi-parametric characterization of lung pathology. Experience with the clinical use of lung MRI is growing. There are now standardized protocols which are easy to implement on current scanner hardware configurations. The image quality has become more robust and currently ongoing studies will help to further contribute experience with multi-center, multi-vendor and multi-platform implementation of this technology. All of the required prerequisites have now been achieved to allow for a dedicated prospective large scale MRI based lung cancer screening trial to investigate the outcomes from using MRI rather than CT for lung cancer screening. This is driven by the hypothesis that MRI would reach a similarly high sensitivity for the detection of early lung cancer with fewer false positive exams (better specificity) than LDCT. The purpose of this review article is to discuss the potential role of lung MRI for the early detection of lung cancer from a technical point of view and to discuss a few of the possible scenarios for lung cancer screening implementation using this imaging modality. There is little doubt that MRI could play a significant role in lung cancer screening, but how and when will depend on the threshold needed for positive screens (e.g. lesion volume and required diagnostic accuracy), cost-effectiveness and improved patient outcomes from a reduction in the need to follow up benign nodules. Potential applications range from lung MRI as the first choice screening modality to the role of an ad hoc on site test for the detailed evaluation of a subgroup of positive screening results. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Explosives screening on a vehicle surface

    DOEpatents

    Parmeter, John E.; Brusseau, Charles A.; Davis, Jerry D.; Linker, Kevin L.; Hannum, David W.

    2005-02-01

    A system for detecting particles on the outer surface of a vehicle has a housing capable of being placed in a test position adjacent to, but not in contact with, a portion of the outer surface of the vehicle. An elongate sealing member is fastened to the housing along a perimeter surrounding the wall, and the elongate sealing member has a contact surface facing away from the wall to contact the outer surface of the vehicle to define a test volume when the wall is in the test position. A gas flow system has at least one gas inlet extending through the wall for providing a gas stream against the surface of the vehicle within the test volume. This gas stream, which preferably is air, dislodges particles from the surface of the vehicle covered by the housing. The gas stream exits the test volume through a gas outlet and particles in the stream are detected.

  8. Measurement of the airway surface liquid volume with simple light refraction microscopy.

    PubMed

    Harvey, Peter R; Tarran, Robert; Garoff, Stephen; Myerburg, Mike M

    2011-09-01

    In the cystic fibrosis (CF) lung, the airway surface liquid (ASL) volume is depleted, impairing mucus clearance from the lung and leading to chronic airway infection and obstruction. Several therapeutics have been developed that aim to restore normal airway surface hydration to the CF airway, yet preclinical evaluation of these agents is hindered by the paucity of methods available to directly measure the ASL. Therefore, we sought to develop a straightforward approach to measure the ASL volume that would serve as the basis for a standardized method to assess mucosal hydration using readily available resources. Primary human bronchial epithelial (HBE) cells cultured at an air-liquid interface develop a liquid meniscus at the edge of the culture. We hypothesized that the size of the fluid meniscus is determined by the ASL volume, and could be measured as an index of the epithelial surface hydration status. A simple method was developed to measure the volume of fluid present in meniscus by imaging the refraction of light at the ASL interface with the culture wall using low-magnification microscopy. Using this method, we found that primary CF HBE cells had a reduced ASL volume compared with non-CF HBE cells, and that known modulators of ASL volume caused the predicted responses. Thus, we have demonstrated that this method can detect physiologically relevant changes in the ASL volume, and propose that this novel approach may be used to rapidly assess the effects of airway hydration therapies in high-throughput screening assays.

  9. A discrete model of Ostwald ripening based on multiple pairwise interactions

    NASA Astrophysics Data System (ADS)

    Di Nunzio, Paolo Emilio

    2018-06-01

    A discrete multi-particle model of Ostwald ripening based on direct pairwise interactions is developed for particles with incoherent interfaces as an alternative to the classical LSW mean field theory. The rate of matter exchange depends on the average surface-to-surface interparticle distance, a characteristic feature of the system which naturally incorporates the effect of volume fraction of second phase. The multi-particle diffusion is described through the definition of an interaction volume containing all the particles involved in the exchange of solute. At small volume fractions this is proportional to the size of the central particle, at higher volume fractions it gradually reduces as a consequence of diffusion screening described on a geometrical basis. The topological noise present in real systems is also included. For volume fractions below about 0.1 the model predicts broad and right-skewed stationary size distributions resembling a lognormal function. Above this value, a transition to sharper, more symmetrical but still right-skewed shapes occurs. An excellent agreement with experiments is obtained for 3D particle size distributions of solid-solid and solid-liquid systems with volume fraction 0.07, 0.30, 0.52 and 0.74. The kinetic constant of the model depends on the cube root of volume fraction up to about 0.1, then increases rapidly with an upward concavity. It is in good agreement with the available literature data on solid-liquid mixtures in the volume fraction range from 0.20 to about 0.75.

  10. Cone-beam volume CT mammographic imaging: feasibility study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  11. Micromachined nanocalorimetric sensor for ultra-low-volume cell-based assays.

    PubMed

    Johannessen, Erik A; Weaver, John M R; Bourova, Lenka; Svoboda, Petr; Cobbold, Peter H; Cooper, Jonathan M

    2002-05-01

    Current strategies for cell-based screening generally focus on the development of highly specific assays, which require an understanding of the nature of the signaling molecules and cellular pathways involved. In contrast, changes in temperature of cells provides a measure of altered cellular metabolism that is not stimulus specific and hence could have widespread applications in cell-based screening of receptor agonists and antagonists, as well as in the assessment of toxicity of new lead compounds. Consequently, we have developed a micromachined nanocalorimetric biological sensor using a small number of isolated living cells integrated within a subnanoliter format, which is capable of detecting 13 nW of generated power from the cells, upon exposure to a chemical or pharmaceutical stimulus. The sensor comprises a 10-junction gold and nickel thermopile, integrated on a silicon chip which was back-etched to span a 800-nm-thick membrane of silicon nitride. The thin-film membrane, which supported the sensing junctions of the thermoelectric transducer, gave the system a temperature resolution of 0.125 mK, a low heat capacity of 1.2 nJ mK(-1), and a rapid (unfiltered) response time of 12 ms. The application of the system in ultra-low-volume cell-based assays could provide a rapid endogenous screen. It offers important additional advantages over existing methods in that it is generic in nature, it does not require the use of recombinant cell lines or of detailed assay development, and finally, it can enable the use of primary cell lines or tissue biopsies.

  12. Path analysis of phenotypic traits in young cacao plants under drought conditions.

    PubMed

    Santos, Emerson Alves Dos; Almeida, Alex-Alan Furtado de; Branco, Marcia Christina da Silva; Santos, Ivanildes Conceição Dos; Ahnert, Dario; Baligar, Virupax C; Valle, Raúl René

    2018-01-01

    Drought is worldwide considered one of the most limiting factors of Theobroma cacao production, which can be intensified by global climate changes. In this study, we aimed to investigate the phenotypic correlation among morphological characteristics of cacao progenies submitted to irrigation and drought conditions and their partitions into direct and indirect effects. Path analysis with phenotypic plasticity index was used as criteria for estimation of basic and explanatory variables. The experiment was conducted in a greenhouse at the Cacao Research Center (CEPEC), Ilhéus, Bahia, Brazil, in a randomized block 21 x 2 factorial arrangement [21 cacao progenies obtained from complete diallel crosses and two water regimes (control and drought)] and six replications. In general, drought conditions influenced biomass production in most progenies, causing significant reductions in total leaf area, leaf number, leaf biomass, fine-roots length (diameter <1 mm), root volume and root area for considered drought intolerant. All progenies showed alterations in growth due to drought. Phenotypic plasticity was most strongly pronounced in root volume. Stem and root diameters, as well as stem dry biomass were the growth variables with the greatest direct effects on root volume under drought conditions, these characters being indicated in screening of cacao progenies drought tolerant.

  13. Path analysis of phenotypic traits in young cacao plants under drought conditions

    PubMed Central

    dos Santos, Emerson Alves; de Almeida, Alex-Alan Furtado; Branco, Marcia Christina da Silva; dos Santos, Ivanildes Conceição; Ahnert, Dario; Baligar, Virupax C.; Valle, Raúl René

    2018-01-01

    Drought is worldwide considered one of the most limiting factors of Theobroma cacao production, which can be intensified by global climate changes. In this study, we aimed to investigate the phenotypic correlation among morphological characteristics of cacao progenies submitted to irrigation and drought conditions and their partitions into direct and indirect effects. Path analysis with phenotypic plasticity index was used as criteria for estimation of basic and explanatory variables. The experiment was conducted in a greenhouse at the Cacao Research Center (CEPEC), Ilhéus, Bahia, Brazil, in a randomized block 21 x 2 factorial arrangement [21 cacao progenies obtained from complete diallel crosses and two water regimes (control and drought)] and six replications. In general, drought conditions influenced biomass production in most progenies, causing significant reductions in total leaf area, leaf number, leaf biomass, fine-roots length (diameter <1 mm), root volume and root area for considered drought intolerant. All progenies showed alterations in growth due to drought. Phenotypic plasticity was most strongly pronounced in root volume. Stem and root diameters, as well as stem dry biomass were the growth variables with the greatest direct effects on root volume under drought conditions, these characters being indicated in screening of cacao progenies drought tolerant. PMID:29408854

  14. Screening for ADHD in adults with cystic fibrosis: Prevalence, health-related quality of life, and adherence.

    PubMed

    Georgiopoulos, Anna M; Friedman, Deborah; Porter, Elizabeth A; Krasner, Amy; Kakarala, Sheetal P; Glaeser, Breanna K; Napoleon, Siena C; Wozniak, Janet

    2018-03-01

    International guidelines recommend depression and anxiety screening in individuals with cystic fibrosis (CF), but Attention-Deficit Hyperactivity Disorder (ADHD) remains understudied. Adults with CF (n=53) were screened using the Adult ADHD Self-Report Scale-v1.1 Symptom Checklist (ASRS-v1.1), Cystic Fibrosis Questionnaire-Revised (CFQ-R), and a self-report measure of treatment adherence. Elevated ADHD symptoms on the ASRS-v1.1 screener were reported by 15% of participants. Self-reported adherence, Body Mass Index in kg/m 2 (BMI), and Forced Expiratory Volume in 1 Second, Percent Predicted (FEV1%pred) did not differ between participants with vs. without elevated ADHD scores. Three CFQ-R scales, Physical Functioning, Role Functioning, and Respiratory Symptoms, were significantly lower in participants with elevated ADHD screens (unadjusted p<0.05). This difference remained statistically significant for the Role Functioning and Respiratory Symptoms scales following correction for multiple comparisons. The highly specific screening tool ASRS-v1.1 can ascertain previously undetected ADHD symptoms in adults with CF. ADHD was substantially more prevalent than expected in this population. Elevated ASRS-v1.1 screens correlated with poorer Health-Related Quality of Life (HRQoL) in some domains, but not with BMI, FEV1%pred, or self-reported CF treatment adherence. Additional research will elucidate the impact of ADHD and its treatment on HRQoL, CF self-care and health outcomes. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  15. Sildenafil Citrate Therapy for Oligohydramnios: A Randomized Controlled Trial.

    PubMed

    Maher, Mohammad Ahmed; Sayyed, Tarek Mohammad; Elkhouly, Nabih

    2017-04-01

    To compare sildenafil plus hydration with hydration alone in improving the amniotic fluid index and neonatal outcomes in pregnancies complicated by idiopathic oligohydramnios ( amniotic fluid index less than 5 cm without underlying maternal or fetal causes and with normal fetal growth). This was an open-label randomized trial for women carrying singleton pregnancies at 30 weeks of gestation or more with idiopathic oligohydramnios detected during routine ultrasonogram. Women received either oral sildenafil citrate (25 mg every 8 hours) plus intravenous infusion of 2 L isotonic solution or fluids only until delivery. The primary study outcome was the amniotic fluid volume at 6 weeks of follow-up or the final volume before delivery, whichever occurred first. Secondary outcomes were duration of pregnancy prolongation, mode of delivery, and select neonatal outcomes. The study was powered to detect a 45% difference between groups, so, at an α level of 0.05 and 80% power, a sample size of 167 women was required. From February 24, 2015, through April 2016, 196 women were screened and 184 were randomized. Follow-up was completed in 166 (90%): 82 in the sildenafil group and 84 in the hydration group. Baseline characteristics were similar between groups. The amniotic fluid volume was higher in the sildenafil group at the final assessment (11.5 compared with 5.4 cm, P=.02). The sildenafil group delivered later (38.3 compared with 36.0 weeks of gestation, P=.001), had a lower rate of cesarean delivery (28% compared with 73%), and their neonates were less likely to be admitted to the neonatal intensive care unit (11% compared with 41%, P=.001). Sildenafil citrate increases amniotic fluid volume in pregnancies complicated by oligohydramnios. ClinicalTrials.gov, www.clinicaltrials.gov, NCT02372487.

  16. BioSig3D: High Content Screening of Three-Dimensional Cell Culture Models

    PubMed Central

    Bilgin, Cemal Cagatay; Fontenay, Gerald; Cheng, Qingsu; Chang, Hang; Han, Ju; Parvin, Bahram

    2016-01-01

    BioSig3D is a computational platform for high-content screening of three-dimensional (3D) cell culture models that are imaged in full 3D volume. It provides an end-to-end solution for designing high content screening assays, based on colony organization that is derived from segmentation of nuclei in each colony. BioSig3D also enables visualization of raw and processed 3D volumetric data for quality control, and integrates advanced bioinformatics analysis. The system consists of multiple computational and annotation modules that are coupled together with a strong use of controlled vocabularies to reduce ambiguities between different users. It is a web-based system that allows users to: design an experiment by defining experimental variables, upload a large set of volumetric images into the system, analyze and visualize the dataset, and either display computed indices as a heatmap, or phenotypic subtypes for heterogeneity analysis, or download computed indices for statistical analysis or integrative biology. BioSig3D has been used to profile baseline colony formations with two experiments: (i) morphogenesis of a panel of human mammary epithelial cell lines (HMEC), and (ii) heterogeneity in colony formation using an immortalized non-transformed cell line. These experiments reveal intrinsic growth properties of well-characterized cell lines that are routinely used for biological studies. BioSig3D is being released with seed datasets and video-based documentation. PMID:26978075

  17. Strategies for Using Plagiarism Software in the Screening of Incoming Journal Manuscripts: Recommendations Based on a Recent Literature Survey.

    PubMed

    Lykkesfeldt, Jens

    2016-08-01

    In recent years, several online tools have appeared capable of identifying potential plagiarism in science. While such tools may help to maintain or even increase the originality and ethical quality of the scientific literature, no apparent consensus exists among editors on the degree of plagiarism or self-plagiarism necessary to reject or retract manuscripts. In this study, two entire volumes of published original papers and reviews from Basic & Clinical Pharmacology & Toxicology were retrospectively scanned for similarity in anonymized form using iThenticate software to explore measures to predictively identify true plagiarism and self-plagiarism and to potentially provide guidelines for future screening of incoming manuscripts. Several filters were applied, all of which appeared to lower the noise from irrelevant hits. The main conclusions were that plagiarism software offers a unique opportunity to screen for plagiarism easily but also that it has to be employed with caution as automated or uncritical use is far too unreliable to allow a fair basis for judging the degree of plagiarism in a manuscript. This remains the job of senior editors. Whereas a few cases of self-plagiarism that would not likely have been accepted with today's guidelines were indeed identified, no cases of fraud or serious plagiarism were found. Potential guidelines are discussed. © 2016 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  18. Microbial biosensor for detection of methyl parathion using screen printed carbon electrode and cyclic voltammetry.

    PubMed

    Kumar, Jitendra; D'Souza, S F

    2011-07-15

    Whole cells of recombinant Escherichia coli were immobilized on the screen printed carbon electrode (SPCE) using glutaraldehyde. Recombinant E. coli was having high periplasmic expression of organophosphorus hydrolase enzyme, which hydrolyzes the methyl parathion into two products, p-nitrophenol and dimethyl thiophosphoric acid. Cells immobilized SPCE was studied under SEM. Cells immobilized SPCE was associated with cyclic voltammetry and cyclic voltammograms were recorded before and after hydrolysis of methyl parathion. Detection was calibrated based on the relationship between the changes in the current observed at +0.1 V potential, because of redox behavior of the hydrolyzed product p-nitrophenol. As concentration of methyl parathion was increased the oxidation current also increased. Only 20 μl volume of the sample was required for analysis. Detection range of biosensor was calibrated between 2 and 80 μM of methyl parathion from the linear range of calibration plot. A single immobilized SPCE was reused for 32 reactions with retention of 80% of its initial enzyme activity. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Virtual screening of inorganic materials synthesis parameters with deep learning

    NASA Astrophysics Data System (ADS)

    Kim, Edward; Huang, Kevin; Jegelka, Stefanie; Olivetti, Elsa

    2017-12-01

    Virtual materials screening approaches have proliferated in the past decade, driven by rapid advances in first-principles computational techniques, and machine-learning algorithms. By comparison, computationally driven materials synthesis screening is still in its infancy, and is mired by the challenges of data sparsity and data scarcity: Synthesis routes exist in a sparse, high-dimensional parameter space that is difficult to optimize over directly, and, for some materials of interest, only scarce volumes of literature-reported syntheses are available. In this article, we present a framework for suggesting quantitative synthesis parameters and potential driving factors for synthesis outcomes. We use a variational autoencoder to compress sparse synthesis representations into a lower dimensional space, which is found to improve the performance of machine-learning tasks. To realize this screening framework even in cases where there are few literature data, we devise a novel data augmentation methodology that incorporates literature synthesis data from related materials systems. We apply this variational autoencoder framework to generate potential SrTiO3 synthesis parameter sets, propose driving factors for brookite TiO2 formation, and identify correlations between alkali-ion intercalation and MnO2 polymorph selection.

  20. Hot melt extrusion of ion-exchange resin for taste masking.

    PubMed

    Tan, David Cheng Thiam; Ong, Jeremy Jianming; Gokhale, Rajeev; Heng, Paul Wan Sia

    2018-05-30

    Taste masking is important for some unpleasant tasting bioactives in oral dosage forms. Among many methods available for taste-masking, use of ion-exchange resin (IER) holds promise. IER combined with hot melt extrusion (HME) may offer additional advantages over solvent methods. IER provides taste masking by complexing with the drug ions and preventing drug dissolution in the mouth. Drug-IER complexation approaches described in literatures are mainly based either on batch processing or column eluting. These methods of drug-IER complexation have obvious limitations such as high solvent volume requirements, multiprocessing steps and extended processing time. Thus, the objective of this study was to develop a single-step, solvent-free, continuous HME process for complexation of drug-IER. The screening study evaluated drug to IER ratio, types of IER and drug complexation methods. In the screening study, a potassium salt of a weakly acidic carboxylate-based cationic IER was found suitable for the HME method. Thereafter, optimization study was conducted by varying HME process parameters such as screw speed, extrusion temperature and drug to IER ratio. It was observed that extrusion temperature and drug to IER ratio are imperative in drug-IER complexation through HME. In summary, this study has established the feasibility of a continuous complexation method for drug to IER using HME for taste masking. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. SpermCheck: a simplified screening assay for immunological infertility.

    PubMed

    McClure, R D; Tom, R A; Watkins, M; Murthy, S

    1989-10-01

    SpermCheck (Bio-Rad Laboratories, Hercules, CA), a new screening test for regional surface antibodies on motile sperm, uses monodispersed latex microspheres of uniform size as a vehicle to link rabbit antihuman immunoglobulins (IgA, IgG, IgM) and provides both negative and positive control sera, as well as sufficient buffer for sperm preparation in ambient CO2 atmosphere. When compared with reference data available for the immunobead test (IBT), the direct protocol (semen) for SpermCheck yielded 94.4% sensitivity with 100% specificity; the indirect protocol (serum) provided a sensitivity of 100% with 94.7% specificity. The microspheres of SpermCheck maintain a nearly uniform concentration per volume, with none to negligible clumping. The greater difference between the optical densities of latex and cytoplasm allows use of a light microscope for the rapid assessment of the percent of regional binding rather than the phase-contrast microscope required for the IBT. SpermCheck eliminates many difficulties encountered with the IBT, making SpermCheck a convenient screening assay for use in the physician's office.

  2. Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds.

    PubMed

    de-Souza-Silva, Calliandra Maria; Guilhelmelli, Fernanda; Zamith-Miranda, Daniel; de Oliveira, Marco Antônio; Nosanchuk, Joshua Daniel; Silva-Pereira, Ildinete; Albuquerque, Patrícia

    2018-02-14

    Fungal infections have become an important medical condition in the last decades, but the number of available antifungal drugs is limited. In this scenario, the search for new antifungal drugs is necessary. The protocol reported here details a method to screen peptides for their antifungal properties. It is based on the broth microdilution susceptibility test from the Clinical and Laboratory Standards Institute (CLSI) M27-A3 guidelines with modifications to suit the research of antimicrobial peptides as potential new antifungals. This protocol describes a functional assay to evaluate the activity of antifungal compounds and may be easily modified to suit any particular class of molecules under investigation. Since the assays are performed in 96-well plates using small volumes, a large-scale screening can be completed in a short amount of time, especially if carried out in an automation setting. This procedure illustrates how a standardized and adjustable clinical protocol can help the bench-work pursuit of new molecules to improve the therapy of fungal diseases.

  3. Evaluation of the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules in CT lung cancer screening

    PubMed Central

    Muramatsu, Yukio; Yamamichi, Junta; Gomi, Shiho; Oubel, Estanislao; Moriyama, Noriyuki

    2018-01-01

    Background This study sought to evaluate the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules. Methods The volumes of 226 solid nodules that had been clinically stable for 5 years were measured in 186 patients (53 female never-smokers, 36 male never-smokers, 51 males with <30 pack-years, and 46 males with ≥30 pack-years) using a three-dimensional semiautomated method. Volume changes were evaluated using three methods: percent change, proportional change and growth rate. The 95% limits of agreement were evaluated using the Bland-Altman method. Results The 95% limits of agreement were as follows: range of percent change, from ±34.5% to ±37.8%; range of proportional change, from ±34.1% to ±36.8%; and range of growth rate, from ±39.2% to ±47.4%. Percent change-based, proportional change-based, and growth rate-based diagnoses of an increase or decrease in ten solid nodules were made at a mean of 302±402, 367±455, and 329±496 days, respectively, compared with a clinical diagnosis made at 809±616 days (P<0.05). Conclusions The 95% limits of agreement for volume change in 5-year stable solid nodules may enable the detection of an increase or decrease in the solid nodule at an earlier stage than that enabled by a clinical diagnosis, possibly contributing to the development of a follow-up system for reducing the number of additional Computed tomography (CT) scans performed during the follow-up period. PMID:29600047

  4. Evaluation of the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules in CT lung cancer screening.

    PubMed

    Kakinuma, Ryutaro; Muramatsu, Yukio; Yamamichi, Junta; Gomi, Shiho; Oubel, Estanislao; Moriyama, Noriyuki

    2018-01-01

    This study sought to evaluate the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules. The volumes of 226 solid nodules that had been clinically stable for 5 years were measured in 186 patients (53 female never-smokers, 36 male never-smokers, 51 males with <30 pack-years, and 46 males with ≥30 pack-years) using a three-dimensional semiautomated method. Volume changes were evaluated using three methods: percent change, proportional change and growth rate. The 95% limits of agreement were evaluated using the Bland-Altman method. The 95% limits of agreement were as follows: range of percent change, from ±34.5% to ±37.8%; range of proportional change, from ±34.1% to ±36.8%; and range of growth rate, from ±39.2% to ±47.4%. Percent change-based, proportional change-based, and growth rate-based diagnoses of an increase or decrease in ten solid nodules were made at a mean of 302±402, 367±455, and 329±496 days, respectively, compared with a clinical diagnosis made at 809±616 days (P<0.05). The 95% limits of agreement for volume change in 5-year stable solid nodules may enable the detection of an increase or decrease in the solid nodule at an earlier stage than that enabled by a clinical diagnosis, possibly contributing to the development of a follow-up system for reducing the number of additional Computed tomography (CT) scans performed during the follow-up period.

  5. Visceral adiposity and high adiponectin levels are associated with the prevalence of pancreatic cystic lesions.

    PubMed

    Mizuno, Suguru; Nakai, Yousuke; Isayama, Hiroyuki; Yoshikawa, Takeharu; Saito, Kei; Takahara, Naminatsu; Kogure, Hirofumi; Tada, Minoru; Hayashi, Naoto; Koike, Kazuhiko

    2018-05-17

    Obesity is increasing in developed countries and is a risk factor for pancreatic cancer (PaC). We previously reported that obesity was associated with pancreatic cystic lesions (PCLs), which are both precursors of, and risk factors for, PaC. In the present study, we further investigated the relationship between visceral adiposity and adiponectin levels and the extent of PCLs. Individuals who underwent comprehensive health screening at our institution between January 2008 and March 2013 were analyzed. PCLs were diagnosed via magnetic resonance imaging using a 3.0 Tesla system. The volumes of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) were measured from computed tomographic volume data. Serum levels of adiponectin were measured using a sandwich enzyme-linked immunosorbent assay. The prevalences of PCLs were 14.2% in males (N = 2683; mean age, 56.4 years) and 16.2% in females (N = 1741; mean age, 57.1 years). The prevalence of PCLs increased gradually as VAT volume increased (P < 0.001). PCLs were more prevalent in individuals with high adiponectin levels (18.7% vs. 13.8%, P = 0.005). VAT volume (odds ratio [OR] for the highest quartiles, 1.52 [1.07-2.16]; P = 0.025) and adiponectin level (OR for the highest quartiles, 1.31 [1.08-1.59]; P = 0.007) but not SAT volume (P = 0.828) was significantly associated with PCLs in multivariate analyses. Visceral adiposity and high adiponectin levels were associated with PCL prevalence. Further work is needed to explore the relationships between visceral adiposity and adiponectin levels, and PCLs and PaC.

  6. The Effect of Colonoscopy Reimbursement Reductions on Gastroenterologist Practice Behavior.

    PubMed

    McNeill, Matthew B; Chang, Shannon; Sahebjam, Farhad; Goodman, Adam J; Gross, Seth A; Sigal, Samuel H

    2016-06-01

    The purpose of this study was to assess the effect of decreased colonoscopy reimbursement on gastroenterologist practice behavior, including time to retirement and procedure volume. In 2015, the Centers for Medicare and Medicaid Services proposed reductions in colonoscopy reimbursements. With new initiatives for increased colorectal cancer screening, it is crucial to understand how reimbursement changes could affect these efforts. Randomly selected respondents from the American College of Gastroenterology membership database were surveyed on incremental changes in practice behavior if colonoscopy reimbursement were to decrease by 10, 20, 30, or 40 %. Data were analyzed using both Pearson's Chi-square and analysis of variance. Two thousand and nine gastroenterologists received the survey with a 16.3 % response rate. Procedure volume significantly decreased with degree of reimbursement reductions (p < 0.001). With a 10 % decrease, 72 % of respondents reported no change in the number of colonoscopies performed. With a 20 % decrease, 39 % would decrease their procedure volume, while 21 % of respondents would increase their procedure volume. With a 30 and 40 % decrease, procedure volume decreased by 48 and 50 %, respectively. In terms of retirement, current plans predict a cumulative retirement rate of 29.4 % at 10 years. More than 42 % of respondents plan to retire after 2030. In the 2014-2023 retirement subgroup (N = 74 responses), there was a significant hastening of retirement year at 20 % (p = 0.016), 30 % (p < 0.001), and 40 % (p < 0.001) reimbursement reductions as compared to baseline responses. Decreasing colonoscopy reimbursements may have a significant effect on the effective gastroenterology work force.

  7. Reduce volume of head-up display by image stitching

    NASA Astrophysics Data System (ADS)

    Chiu, Yi-Feng; Su, Guo-Dung J.

    2016-09-01

    Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.

  8. Impact of entrainment and impingement on fish populations in the Hudson River Estuary. Volume II. Impingement impact analyses, evaluations of alternative screening devices, and critiques of utility testimony relating to density-dependent growth, the age-composition of the striped bass spawning stock, and the LMS real-time life cycle model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnthouse, L. W.; Van Winkle, W.; Golumbek, J.

    1982-04-01

    This volume includes a series of four exhibits relating to impacts of impingement on fish populations, together with a collection of critical evaluations of testimony prepared for the utilities by their consultants. The first exhibit is a quantitative evaluation of four sources of bias (collection efficiency, reimpingement, impingement on inoperative screens, and impingement survival) affecting estimates of the number of fish killed at Hudson River power plants. The two following exhibits contain, respectively, a detailed assessment of the impact of impingement on the Hudson River white perch population and estimates of conditional impingement mortality rates for seven Hudson River fishmore » populations. The fourth exhibit is an evaluation of the engineering feasibility and potential biological effectiveness of several types of modified intake structures proposed as alternatives to cooling towers for reducing impingement impacts. The remainder of Volume II consists of critical evaluations of the utilities' empirical evidence for the existence of density-dependent growth in young-of-the-year striped bass and white perch, of their estimate of the age-composition of the striped bass spawning stock in the Hudson River, and of their use of the Lawler, Matusky, and Skelly (LMS) Real-Time Life Cycle Model to estimate the impact of entrainment and impingement on the Hudson River striped bass population.« less

  9. Software Description for the O’Hare Runway Configuration Management System. Volume II. Low-Level Pseudocode,

    DTIC Science & Technology

    1982-10-01

    BACK_ GVRATON; (geserate log me"ses from wather and wind planning log screenJ PERFORN AIPORT.PLANNIG LOGISSA ORItATION; (eSamrate log message from...ISSAGN H31.TAL(COUNT) .26 -kAUX imesase is constructed with wather imforimetiom ad stated) IF(VILO.TAM(J).DIl A(S)’ ’)1 (VXLOG.TABL(J).VU.(S)’ THEN

  10. Eddy-Current Detection of Weak Bolt Heads

    NASA Technical Reports Server (NTRS)

    Messina, C. P.

    1987-01-01

    Electronic test identifies flawed units passing hardness tests. Eddy-current test detects weakness in head-to-shank junctions of 1/4-28 cup-washer lock bolts. Developed for alloy A286 steel bolts in Space Shuttle main engine fuel turbo-pump. Test examines full volume of head, including head-to-shank transition and nondestructively screens out potentially defective units. Test adapts to any other alloys.

  11. Computer program for analysis of high speed, single row, angular contact, spherical roller bearing, SASHBEAN. Volume 1: User's guide

    NASA Technical Reports Server (NTRS)

    Aggarwal, Arun K.

    1993-01-01

    The computer program SASHBEAN (Sikorsky Aircraft Spherical Roller High Speed Bearing Analysis) analyzes and predicts the operating characteristics of a Single Row, Angular Contact, Spherical Roller Bearing (SRACSRB). The program runs on an IBM or IBM compatible personal computer, and for a given set of input data analyzes the bearing design for it's ring deflections (axial and radial), roller deflections, contact areas and stresses, induced axial thrust, rolling element and cage rotation speeds, lubrication parameters, fatigue lives, and amount of heat generated in the bearing. The dynamic loading of rollers due to centrifugal forces and gyroscopic moments, which becomes quite significant at high speeds, is fully considered in this analysis. For a known application and it's parameters, the program is also capable of performing steady-state and time-transient thermal analyses of the bearing system. The steady-state analysis capability allows the user to estimate the expected steady-state temperature map in and around the bearing under normal operating conditions. On the other hand, the transient analysis feature provides the user a means to simulate the 'lost lubricant' condition and predict a time-temperature history of various critical points in the system. The bearing's 'time-to-failure' estimate may also be made from this (transient) analysis by considering the bearing as failed when a certain temperature limit is reached in the bearing components. The program is fully interactive and allows the user to get started and access most of its features with a minimal of training. For the most part, the program is menu driven, and adequate help messages were provided to guide a new user through various menu options and data input screens. All input data, both for mechanical and thermal analyses, are read through graphical input screens, thereby eliminating any need of a separate text editor/word processor to edit/create data files. Provision is also available to select and view the contents of output files on the monitor screen if no paper printouts are required. A separate volume (Volume-2) of this documentation describes, in detail, the underlying mathematical formulations, assumptions, and solution algorithms of this program.

  12. Bowel preparation for colonoscopy with magnesium sulphate and low-volume polyethylene glycol.

    PubMed

    Tepeš, Bojan; Mlakar, Dominika N; Metličar, Tanja

    2014-06-01

    Patient compliance with bowel cleansing procedures represents one of the most objectionable aspects of colonoscopy. Adverse reactions to the purgative may result in failure to complete the preparation, inadequate visualization of the colon, polyp and even carcinoma miss rate and unwillingness to attend a follow-up colonoscopy. The primary objective of the study was to evaluate the effectiveness of bowel cleansing with magnesium sulphate and low-volume polyethylene glycol (PEG) with electrolytes. The second objective was to evaluate whether bowel cleansing was better in participants scheduled for morning colonoscopies or afternoon colonoscopies. Magnesium sulphate mineral water (2 l) and 2 l of low-volume PEG and electrolytes solution were used as our bowel cleansing protocol. A total of 13 914 participants, who participated in the Slovenian colorectal cancer screening programme in the period between 2009 and 2011, were included. Excellent bowel preparation was achieved in 11 484 (82.61%) participants; 1894 (13.62%) participants had good bowel preparation, 439 (3.16%) participants had fair bowel preparation and 85 (0.61%) participants had poor bowel preparation. Better results were achieved in the afternoon colonoscopies and in younger participant groups (P<0.001). No serious side effects of bowel cleansing were reported. This is the first study to use magnesium sulphate mineral water and PEG plus electrolytes for bowel cleansing. We found excellent bowel cleansing in 82.61% participants and in more participants if colonoscopy was performed in the afternoon.

  13. Diagnostic utility of three-dimensional power Doppler ultrasound for postmenopausal bleeding.

    PubMed

    Kim, Ari; Lee, Ji Young; Chun, Sungwook; Kim, Heung Yeol

    2015-06-01

    We evaluated the role of three-dimensional power Doppler ultrasound (3D PD-US) to detect endometrial lesions in women with postmenopausal endometrial bleeding. In this prospective observational study, from January 2009 to November 2012, we recruited 225 postmenopausal women with postmenopausal uterine bleeding who met the study criteria. Women who had hematologic disease, chronic medical diseases, or nonuterine pelvic diseases were excluded. Prior to endometrial biopsy, the patients underwent a baseline transvaginal ultrasound screening. The vascular indices and endometrial volumes were calculated with 3D PD-US and compared with the endometrial histopathology. Among the endometrial histopathologic findings of 174 women, atrophic endometrium was the most common finding (30.5%). Endometrial malignancy was confirmed in 28 cases (16.1%), and endometrial hyperplasia was diagnosed in 17 cases (9.8%). The prevalence of endometrial cancer was high in patients who had endometrial thickness >9.5 mm (p < 0.001) and volume greater than 4.05 mL (p < 0.001). For the endometrial carcinoma only, the cutoff values of vascular index, flow index, and vascular flow index for predicting malignancy were 13.070, 12.610, and 3.764, respectively. For endometrial hyperplasia, endometrial thickness and vascular flow index were significant findings. Endometrial vasculature and volume can be obtained using 3D PD-US. The diagnostic usefulness of 3D PD-US for endometrial diseases is promising in women with postmenopausal endometrial bleeding. Copyright © 2015. Published by Elsevier B.V.

  14. Audit system on Quality of breast cancer diagnosis and Treatment (QT): results of quality indicators on screen-detected lesions in Italy, 2011-2012.

    PubMed

    Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Casella, Denise; D'Ambrosio, Enrico; Delos, Erika; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Giudici, Fabiola; Mantellini, Paola; Naldoni, Carlo; Olla Atzeni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Pitarella, Sabina; Ravaioli, Alessandra; Silvestri, Anna; Taffurelli, Mario; Tidone, Enrica; Zanconati, Fabrizio; Segnan, Nereo

    2015-01-01

    This annual survey, conducted by the Italian group for mammography screening (GISMa), collects individual data on diagnosis and treatment of about 50% of screen-detected, operated lesions in Italy. The 2011-2012 results show good overall quality and an improving trend over time. A number of critical issues have been identified, including waiting times (which have had a worsening trend over the years) and compliance with the recommendation of not performing frozen section examination on small lesions. Pre-operative diagnosis improved constantly over time, but there is still a large variation between Regions and programmes. For almost 90% of screen-detected invasive cancers a sentinel lymph node (SLN) biopsy was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN dissection for ductal carcinoma in situ, although apparently starting to decline, deserves further investigation. The detailed results have been distributed, among other ways by means of a web-based data-warehouse, to regional and local screening programmes, in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. The problem of waiting times should be assigned priority. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.

  15. Single jugular vein cannulated rats may not be suitable for intravenous pharmacokinetic screening of high logP compounds.

    PubMed

    Gaud, Nilesh; Kumar, Anoop; Matta, Muralikrishna; Kole, Prashant; Sridhar, Srikanth; Mandlekar, Sandhya; Holenarsipur, Vinay K

    2017-03-01

    Rat is commonly used for pharmacokinetic screening during pharmaceutical lead optimization. To handle the large number of compounds, rats with a single jugular vein cannulation are commonly utilized for intravenous pharmacokinetic studies, where the same cannula is used both for dose administration and blood sampling. We demonstrate that the single cannula method is not suitable for all compounds, especially for high logP compounds. We propose an alternative dual cannulation technique in which two cannulas are placed in the same jugular vein, thus avoiding an additional surgery. Compounds were administered orally or via intravenous infusion to compare PK parameters, including bioavailability, using both procedures. For itraconazole and amiodarone, known to bind to the cannula, the measured plasma exposures were substantially higher in the single cannulated rats than those from dual cannulated rats. Area under the plasma concentration time curve differed by 79% and 74% for itraconazole and amiodarone, respectively. When compared to the single cannulation approach, clearance, volume of distribution and bioavailability determined by dual cannulation were 39%, 60% and 38% higher for itraconazole, and 46%, 34% and 42% higher for amiodarone, respectively. In contrast, all pharmacokinetic parameters were similar between single and dual-cannulated rats for the hydrophilic compound atenolol. Based on these results, we recommend the use of dual cannulated rats for intravenous pharmacokinetic studies when testing a series of hydrophobic compounds that may be prone to non-specific binding to the cannula. If single cannulated model is selected for pharmacokinetic screening, we recommend a bridging study with dual cannulated rats with representative compounds of a given chemical series. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Anaemia in pregnancy in the district of Anuradhapura, Sri Lanka--need for updating prevalence data and screening strategies.

    PubMed

    Chathurani, U; Dharshika, I; Galgamuwa, D; Wickramasinghe, N D; Agampodi, T C; Agampodi, S B

    2012-09-01

    To determine the prevalence of anaemia during pregnancy in Anuradhapura district and evaluate present screening methods for anaemia. Modified WHO 30 cluster sampling method with increased precision was used to estimate the prevalence of anaemia in the Anuradhapura district, Sri Lanka. Serum haemoglobin was measured using methemoglobin method. Clinical examination was carried out to evaluate the conjunctival method in anaemia screening. Values recorded from haemoglobin colour scale method used in the field antenatal clinics were collected. A total of 990 pregnant women participated in the study. In the first, second and third trimesters, prevalence of anaemia was 7.6%, 19.7% and 19.3% respectively. Gestational age adjusted anaemia prevalence among pregnant women in this study population was 14.1% (95% CI 12.0-16.4%). Mean and median haemoglobin concentration of the study sample was 11.8g/dL (SD 1.02g/dl and IQR 11.2-12.5g/dl). Among anaemic pregnant women, average values for Mean Corpuscular Volume (MCV), Mean Corpuscular Haemoglobin (MCH), and Mean Corpuscular Haemoglobin Concentration (MCHC) were, 82.9 fl (SD 11.5), 27.6 (SD-3.6) pg/cell and 32.9g/dl (SD 1.8) respectively. Sensitivity and specificity of haemoglobin colour scale method was 50% (95% CI 29.0-71.0%) and 76.3% (95% CI 66.9-83.7%) respectively. Sensitivity and specificity of conjunctival method in detecting anaemia during pregnancy was 18.8% (95% CI 11.9-28.4) and 69.3% (95% CI 58.2- 78.6%). Prevalence of anaemia in the district of Anuradhapura was less than 50% of the estimated prevalence for Sri Lanka. Both haemoglobin colour scale and conjunctival method were having low validity in detecting anaemia in pregnancy.

  17. A Morbidity Screening Tool for identifying fatigue, pain, upper limb dysfunction and lymphedema after breast cancer treatment: a validity study.

    PubMed

    Bulley, Catherine; Coutts, Fiona; Blyth, Christine; Jack, Wilma; Chetty, Udi; Barber, Matthew; Tan, Chee Wee

    2014-04-01

    This study aimed to investigate validity of a newly developed Morbidity Screening Tool (MST) to screen for fatigue, pain, swelling (lymphedema) and arm function after breast cancer treatment. A cross-sectional study included women attending reviews after completing treatment (surgery, chemotherapy and radiotherapy), without recurrence, who could read English. They completed the MST and comparator questionnaires: Disability of the Arm, Shoulder and Hand questionnaire (DASH), Chronic Pain Grade Questionnaire (CPGQ), Lymphedema and Breast Cancer Questionnaire (LBCQ) and Functional Assessment of Cancer Therapy questionnaire with subscales for fatigue (FACT F) and breast cancer (FACT B + 4). Bilateral combined shoulder ranges of motion were compared (upward reach; hand behind back) and percentage upper limb volume difference (%LVD =/>10% diagnosed as lymphedema) measured with the vertical perometer (400T). 613 of 617 participants completed questionnaires (mean age 62.3 years, SD 10.0; mean time since treatment 63.0 months, SD 46.6) and 417 completed objective testing. Morbidity prevalence was estimated as 35.8%, 21.9%, 19.8% and 34.4% for fatigue, impaired upper limb function, lymphedema and pain respectively. Comparing those self-reporting the presence or absence of each type of morbidity, statistically significant differences in comparator variables supported validity of the MST. Statistically significant correlations resulted between MST scores focussing on impact of morbidity, and comparator variables that reflect function and quality of life. Analysis supports the validity of all four short-forms of the MST as providing indications of both presence of morbidity and impacts on participants' lives. This may facilitate early and appropriate referral for intervention. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Forecasting the impact of stereotactic ablative radiotherapy for early-stage lung cancer on the thoracic surgery workforce.

    PubMed

    Edwards, Janet P; Datta, Indraneel; Hunt, John Douglas; Stefan, Kevin; Ball, Chad G; Dixon, Elijah; Grondin, Sean C

    2016-06-01

    To predict variation in thoracic surgery workforce requirements with the introduction of stereotactic ablative radiotherapy (SABR) for the treatment of early-stage non-small-cell lung cancer (NSCLC). Using Canadian census microdata and the Canadian Community Health Survey, a microsimulation model representing the national population was developed. The demand component simulates the incidence of lung cancer, incorporating the impact of computed tomography (CT) screening for high-risk individuals (>30 pack-year smoking history; age 55-74 years). The supply component simulates the number of thoracic surgeons. SABR was introduced into the model to predict changes in the number of operable NSCLC cases per thoracic surgeon, modelling 30, 60 and 90% compliance with SABR for Stage IA and then for both Stage IA and IB NSCLC. In the absence of SABR, the volume of operative NSCLC per surgeon increases by a peak of 49.4% (by 2027) and then gradually declines to the present day volume by 2049. More dramatic decreases are seen with increasing compliance with SABR for Stage IA/IB NSCLCs. If the number of new surgeons entering the workforce per year were reduced by 33%, the operative volume per surgeon would increase by a peak of 57.1% (30% Stage IA SABR compliance) and would decrease by up to 49.1% (90% Stage IA SABR compliance). With the implementation of SABR for treatment of early NSCLC, there would be a decrease in operative volume. The impact would depend on the stage of NSCLC for which SABR is recommended and on compliance. A national strategy for thoracic surgery workforce planning is necessary, given the complex interaction of CT screening and the treatment of medically operable early NSCLC with SABR. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, Erlend K.F.; Hole, Knut Hakon; Lund, Kjersti V.

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test,more » resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.« less

  20. [Factors impacting the growth and nutritional status of cystic fibrosis patients younger than 10 years of age who did not undergo neonatal screening].

    PubMed

    Hortencio, Taís Daiene Russo; Nogueira, Roberto José Negrão; Marson, Fernando Augusto de Lima; Hessel, Gabriel; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando

    2015-01-01

    The aim of this study was to evaluate by clinical and laboratory parameters how cystic fibrosis (CF) affects growth and nutritional status of children who were undergoing CF treatment but did not receive newborn screening. A historical cohort study of 52 CF patients younger than 10 years of age were followed in a reference center in Campinas, Southeast Brazil. Anthropometric measurements were abstracted from medical records until March/2010, when neonatal screening program was implemented. Between September/2009 and March/2010, parental height of the 52 CF patients were also measured. Regarding nutritional status, four patients had Z-scores ≤ -2 for height/age (H/A) and body mass index/age (BMI/A). The following variables were associated with improved H/A ratio: fewer hospitalizations, longer time from first appointment to diagnosis, longer time from birth to diagnosis and later onset of respiratory disease. Forced vital capacity [FVC(%)], forced expiratory flow between 25-75% of FVC [FEF25-75(%)], forced expiratory volume in the first second [FEV1(%)], gestational age, birth weight and early respiratory symptoms were associated with IMC/A. Greater number of hospitalizations, diagnosis delay and early onset of respiratory disease had a negative impact on growth. Lower spirometric values, lower gestational age, lower birth weight, and early onset of respiratory symptoms had negative impact on nutritional status. Malnutrition was observed in 7.7% of cases, but 23% of children had nutritional risk. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

Top