Sample records for screening test fast

  1. Fasting glycaemia to simplify screening for gestational diabetes.

    PubMed

    Ryser Rüetschi, J; Jornayvaz, F R; Rivest, R; Huhn, E A; Irion, O; Boulvain, M

    2016-12-01

    Recommendations in Switzerland on screening for gestational diabetes endorse the International Association of Diabetes in Pregnancy Study Group consensus. As universal testing is time consuming and glucose loading is unpleasant, the recommendations include a simplification, not performing the glucose loading in women with fasting glycaemia <4.4 mmol/l. Our objective was to evaluate the diagnostic performance of this simplified strategy, compared with the complete test, in our population with a low prevalence of gestational diabetes. We collected 2298 complete 75-g glucose tolerance tests. We simulated stopping the test, so avoiding the glucose loading and further glycaemia, if fasting glycaemia was <4.4 or ≥5.1 mmol/l. Unselected pregnant women from Geneva and Basel, at 24-28 weeks of gestation. We calculated the sensitivity, and the percentage of women who would avoid the complete test with the strategy based on fasting glycaemia. The prevalence of gestational diabetes was 10.9% in our population. Among 251 women with gestational diabetes, fasting glycaemia was ≥5.1 mmol/l in 119 women (47.4%), between 4.4 and <5.1 mmol/l in 78 women (31.1%) and <4.4 mmol/l in 54 women (21.5%). Proceeding with the complete test only in women with fasting glycaemia between 4.4 and <5.1 mmol/l will result in a sensitivity of 78.5%. This strategy would avoid glucose loading in 63.8% of women. Screening with fasting glycaemia is an attractive alternative to universal screening with the complete 75-g glucose tolerance test. This strategy is, however, slightly less sensitive than previously reported in higher-risk populations. Fasting glycaemia can be considered as an alternative to the complete test for gestational diabetes screening. © 2016 Royal College of Obstetricians and Gynaecologists.

  2. Depletion of penicillin G residues in sows after intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the Food Safety Inspection Service (FSIS) switched from using the Fast Antimicrobial Screen Test (FAST) for screening animal tissues for penicillin to using the Charm-Kidney Inhibition Swab test (KIS). The switch provided a quicker test and lower detection limits for penicillin when used o...

  3. Fasting Might Not Be Necessary Before Lipid Screening: A Nationally Representative Cross-sectional Study

    PubMed Central

    Skinner, Asheley Cockrell; Perrin, Eliana M.

    2011-01-01

    BACKGROUND: There are barriers to fasting lipid screening for at-risk children. Results of studies in adults have suggested that lipid testing might be reliably performed without fasting. OBJECTIVE: To examine population-level differences in pediatric lipid values based on length of fast before testing. METHODS: We used the National Health and Nutrition Examination Survey (1999–2008) to examine total cholesterol (TC), HDL (high-density lipoprotein), LDL (low-density lipoprotein), and triglyceride cholesterol components on the basis of the period of fasting. Young children fasted for varying times before being tested, and children older than 12 years were asked to fast; however, adherence was variable. We used ordinary least-squares regression to test for differences in lipid values that were based on fasting times, controlling for weight status, age, race, ethnicity, and gender. RESULTS: TC, HDL, LDL, or triglyceride values were available for 12 744 children. Forty-eight percent of the TC and HDL samples and 80% of the LDL and triglyceride samples were collected from children who had fasted ≥8 hours. Fasting had a small positive effect for TC, HDL, and LDL, resulting in a mean value for the sample that was 2 to 5 mg/dL higher with a 12-hour fast compared with a no-fast sample. Fasting time had a negative effect on triglycerides (β = −0.859; P = .02), which resulted in values in the fasting group that were 7 mg/dL lower. DISCUSSION: Comparison of cholesterol screening results for a nonfasting group of children compared with results for a similar fasting group resulted in small differences that are likely not clinically important. Physicians might be able to decrease the burden of childhood cholesterol screening by not requiring prescreening fasting for these components. PMID:21807697

  4. Fetal acoustic stimulation test for early intrapartum fetal monitoring.

    PubMed

    Goonewardene, M; Hanwellage, K

    2011-03-01

    The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p < 0.001), specificity (100% vs 87%, p = 0.017), positive predictive value (100% vs 98%, p = 0.024), negative predictive value (79% vs 17%, p < 0.001) and accuracy (99%vs 64%, p < 0.001) in predicting 5 minute APGAR < 7 in the baby. FAST is a reliable screening test for assessing fetal well being in early labour. It complements the NST and is better than the NST alone.

  5. Novel design strategy for checkpoint kinase 2 inhibitors using pharmacophore modeling, combinatorial fusion, and virtual screening.

    PubMed

    Lin, Chun-Yuan; Wang, Yen-Ling

    2014-01-01

    Checkpoint kinase 2 (Chk2) has a great effect on DNA-damage and plays an important role in response to DNA double-strand breaks and related lesions. In this study, we will concentrate on Chk2 and the purpose is to find the potential inhibitors by the pharmacophore hypotheses (PhModels), combinatorial fusion, and virtual screening techniques. Applying combinatorial fusion into PhModels and virtual screening techniques is a novel design strategy for drug design. We used combinatorial fusion to analyze the prediction results and then obtained the best correlation coefficient of the testing set (r test) with the value 0.816 by combining the Best(train)Best(test) and Fast(train)Fast(test) prediction results. The potential inhibitors were selected from NCI database by screening according to Best(train)Best(test) + Fast(train)Fast(test) prediction results and molecular docking with CDOCKER docking program. Finally, the selected compounds have high interaction energy between a ligand and a receptor. Through these approaches, 23 potential inhibitors for Chk2 are retrieved for further study.

  6. Analysis of microbiological screen test data for antimicrobial residues in food animals.

    PubMed

    Dey, B P; Thaler, Alice; Gwozdz, Frank

    2003-05-01

    This study analyzes the National Residue Program (NRP) of the Food Safety and Inspection Service (FSIS), United States Department of Agriculture (USDA), data for the years 1983-1998 to determine the effectiveness of all three microbiological screen tests that were developed and used by the FSIS to control antimicrobial residues in food animals. The Swab Test On Premises (STOP) was the first screen test introduced in slaughterhouses, followed by the Calf Antibiotic Sulfonamide Test (CAST) and the Fast Antimicrobial Screen Test (FAST). The data for STOP indicates that during 1983-1998, the rate of food animal carcasses with violative levels of antimicrobial residues reduced from 2.33% to 0.45% under the monitoring plan and under the surveillance plan, the rate reduced from 55.1% to 0.56%. Similarly, the data for CAST indicates that the rate of calf carcasses with violative levels of antimicrobial residue also declined significantly during those years. Because of its higher sensitivity and shorter analytical time, the use of FAST started in 1995. By 1999, it had practically replaced the use of STOP and CAST in bovine species. The use of only one test such as FAST instead of different tests has removed confusion for testing different species of food animals and thereby has enhanced the efficiency of the NRP.

  7. The Effect of a Coloring Prompt on Health Engagement

    ClinicalTrials.gov

    2017-05-03

    In Need of a Pap Smear (Cervical Cancer Screening); In Need of a Blood Pressure Check (Hypertension Screening); In Need of a Cholesterol Test (Lipid Disorder Screening); In Need of a Fasting Plasma Glucose Test (Diabetes)

  8. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  9. Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.

    PubMed

    Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N

    2007-05-01

    This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.

  10. Cholesterol and Your Child

    MedlinePlus

    ... can order a simple blood test , usually done fasting (nothing to eat or drink, except water, for ... screening healthy kids without risk factors, a non-fasting blood test can be used. According to the ...

  11. Gestational diabetes mellitus: Screening with fasting plasma glucose.

    PubMed

    Agarwal, Mukesh M

    2016-07-25

    Fasting plasma glucose (FPG) as a screening test for gestational diabetes mellitus (GDM) has had a checkered history. During the last three decades, a few initial anecdotal reports have given way to the recent well-conducted studies. This review: (1) traces the history; (2) weighs the advantages and disadvantages; (3) addresses the significance in early pregnancy; (4) underscores the benefits after delivery; and (5) emphasizes the cost savings of using the FPG in the screening of GDM. It also highlights the utility of fasting capillary glucose and stresses the value of the FPG in circumventing the cumbersome oral glucose tolerance test. An understanding of all the caveats is crucial to be able to use the FPG for investigating glucose intolerance in pregnancy. Thus, all health professionals can use the patient-friendly FPG to simplify the onerous algorithms available for the screening and diagnosis of GDM - thereby helping each and every pregnant woman.

  12. Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC).

    PubMed

    de Jager, L S; Andrews, A R

    2000-11-01

    A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.

  13. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    PubMed

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  14. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2010-10-01 2010-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  15. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2014-10-01 2014-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  16. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2012-10-01 2012-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  17. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2013-10-01 2013-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  18. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2011-10-01 2011-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  19. Anxiety levels in women undergoing prenatal maternal serum screening for Down syndrome: the effect of a fast reporting system by mobile phone short-message service.

    PubMed

    Cheng, Po-Jen; Wu, Tzong-Lin; Shaw, Sheng-Wen; Chueh, Ho-Yen; Lin, Cheng-Tao; Hsu, Jenn-Jeih; Hsieh, T'sang-T'ang; Soong, Yung-Kuei

    2008-05-01

    To study the effect of fast reporting by mobile phone short-message service (SMS) on anxiety levels in women undergoing prenatal biochemical screening for Down syndrome. From January 2005 to December 2006, 2782 women undergoing prenatal biochemical serum screening were randomized into fast reporting by SMS (group A) or without mobile phone reporting (group B). Anxiety levels were measured with the Spielberger State-Trait Anxiety Inventory (STAI) before prenatal screen testing, before the appointed clinic (when the SMS report had already been given to group A), and 3 days after the appointed clinic (when the full screening report had been given to groups A and B). For screen-negative women, anxiety scores did not differ between groups before prenatal screen testing and 3 days after the appointed clinic. The state-anxiety scores measured on the second occasion had declined significantly in group A. The state-anxiety scores in both groups increased over the 3-week period after being informed of positive screen results. The trait- and state-anxiety scores at all points did not differ between the two groups of screen-positive women. The provision of a routine reporting system plus additional SMS report revealed some overall benefits in reducing anxiety among women with screen-negative result. 2008 John Wiley & Sons, Ltd

  20. A fast boosting-based screening method for large-scale association study in complex traits with genetic heterogeneity.

    PubMed

    Wang, Lu-Yong; Fasulo, D

    2006-01-01

    Genome-wide association study for complex diseases will generate massive amount of single nucleotide polymorphisms (SNPs) data. Univariate statistical test (i.e. Fisher exact test) was used to single out non-associated SNPs. However, the disease-susceptible SNPs may have little marginal effects in population and are unlikely to retain after the univariate tests. Also, model-based methods are impractical for large-scale dataset. Moreover, genetic heterogeneity makes the traditional methods harder to identify the genetic causes of diseases. A more recent random forest method provides a more robust method for screening the SNPs in thousands scale. However, for more large-scale data, i.e., Affymetrix Human Mapping 100K GeneChip data, a faster screening method is required to screening SNPs in whole-genome large scale association analysis with genetic heterogeneity. We propose a boosting-based method for rapid screening in large-scale analysis of complex traits in the presence of genetic heterogeneity. It provides a relatively fast and fairly good tool for screening and limiting the candidate SNPs for further more complex computational modeling task.

  1. The utility of direct agglutination (DAT) and fast agglutination screening (FAST) tests in serodiagnosis of experimental microsporidiosis.

    PubMed

    Abou El Naga, Iman F; Gaafar, Maha R; El-Zawawy, Lobna A; El-Said, Doaa; Mossallam, Sherin F

    2008-12-01

    The present study was designed to evaluate the efficiency of two serodiagnostic tests; the direct agglutination test (DAT) and the fast agglutination screening test (FAST) in the diagnosis of Microsporidia in experimentally infected mice and to differentiate between different species of the parasite. The swiss albino mice were divided into non infected control and infected experimental groups which were further subdivided into ten subgroups. Ten samples of microsporidial spores were isolated from ten human stools and each one was used to infect each subgroup of mice. Stool and sera were collected weekly from each subgroup from the 1st to the 4th week post infection (PI). DAT & FAST tests, using antigen prepared from the different species of microsporidial spores were used to detect antibodies in sera of different mice subgroups. The cross reactivity of microsporidial spores with the antibodies of Cyclospora cyatenensis and Cryptosporidium parvum was investigated by DAT & FAST. The results proved that DAT & FAST were effective in detecting microsporidial antibodies in sera of experimentally infected mice from the 2nd week PI till the end of the study, without cross reactivity with C. cyatenensis or C. parvum. They failed to differentiate between different Microspoiridia species used but, they gave good interpretation and they were specific and sensitive, and did not need sophisticated equipments.

  2. Can HbA1c be Used to Screen for Glucose Abnormalities Among Adults with Severe Mental Illness?

    PubMed

    Romain, A J; Letendre, E; Akrass, Z; Avignon, A; Karelis, A D; Sultan, A; Abdel-Baki, A

    2017-04-01

    Aim: Prediabetes and type 2 diabetes are highly prevalent among individuals with serious mental illness and increased by antipsychotic medication. Although widely recommended, many obstacles prevent these patients from obtaining a proper screening for dysglycemia. Currently, glycated hemoglobin (HbA1c), fasting glucose, and 2-hour glucose levels from the oral glucose tolerance test are used for screening prediabetes and type 2 diabetes. The objective of this study was to investigate if HbA1c could be used as the only screening test among individuals with serious mental illness. Methods: Cross sectional study comparing the sensitivity of HbA1c, fasting glucose, and 2-h oral glucose tolerance test to detect dysglycemias in serious mental illness participants referred for metabolic complications. Results: A total of 84 participants (43 female; aged: 38.5±12.8 years; BMI: 35.0±6.8 kg/m²) was included. Regarding prediabetes, 44, 44 and 76% were identified by HbA1c, fasting glucose, and 2 h- oral glucose tolerance test respectively and for type 2 diabetes, 60, 53 and 66% were identified by HbA1c, fasting glucose and 2 h-oral glucose tolerance test. The overlap between the 3 markers was low (8% of participants for prediabetes and 26% for Type 2 diabetes). Sensitivity of HbA1c were moderate (range 40-62.5%), while its specificity was excellent (92-93%). Conclusion: The present study indicates a low agreement between HbA1c, fasting glucose and 2-h oral glucose tolerance test. It appears that these markers do not identify the same participants. Thus, HbA1c may not be used alone to detect all glucose abnormalities among individuals with serious mental illness. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Fasting capillary blood glucose: an appropriate measurement in screening for diabetes and pre-diabetes in low-resource rural settings.

    PubMed

    Zhao, X; Zhao, W; Zhang, H; Li, J; Shu, Y; Li, S; Cai, L; Zhou, J; Li, Y; Hu, R

    2013-01-01

    To evaluate the efficiency of fasting capillary blood glucose (FCG) measurement as compared with fasting venous plasma glucose (FPG) measurement in screening diabetes and pre-diabetes in low-resource rural settings. In 2010, 993 participants were randomly selected from 9 villages in Yunnan province using cluster sampling method. Samples for FCG and FPG test were obtained after demographics and physical examination. The oral glucose tolerance test was performed in parallel as gold standard for diagnosis. Diagnostic capacities of the FCG measurement in predicting undiagnosed diabetes and pre-diabetes were assessed. The performance of FCG and FPG tests was compared. Fifty-seven individuals with undiagnosed diabetes and 145 subjects with pre-diabetes were detected. The concordance between FCG and FPG levels was high (r = 0.75, p < 0.001). The area under the curve (AUC) for FCG test in predicting diabetes was 0.88 [95% confidence interval (CI) 0.82-0.93] with the optimal cutoff value of 5.65 mmol/l, sensitivity of 84.2%, and specificity of 79.3%. The corresponding values in FPG tests were 0.92 (95% CI 0.88-0.97) (AUC), 6.51 mmol/l (optimal cutoff point), 82.5% (sensitivity) and 98.3% (specificity), respectively. No significant difference was found in the AUC for the two screening strategies. FCG measurement is considered to be a convenient, practicable screening method in low-resource rural communities with acceptable test properties.

  4. Blood sugar test

    MedlinePlus

    ... sugar; Blood sugar level; Fasting blood sugar; Glucose test; Diabetic screening - blood sugar test; Diabetes - blood sugar test ... The test may be done in the following ways: After you have not eaten anything for at least 8 ...

  5. Metabolic screening in patients with polycystic ovary syndrome is largely underutilized among obstetrician-gynecologists.

    PubMed

    Dhesi, Amy S; Murtough, Katie L; Lim, Jonathan K; Schulkin, Jay; McGovern, Peter G; Power, Michael L; Morelli, Sara S

    2016-11-01

    Women with polycystic ovary syndrome have substantially higher rates of insulin resistance, impaired glucose tolerance, type 2 diabetes, dyslipidemia, and metabolic syndrome when compared with women without the disease. Given the high prevalence of these comorbidities, guidelines issued by the American College of Obstetricians and Gynecologists and the Endocrine Society recommend that all women with polycystic ovary syndrome undergo screening for impaired glucose tolerance and dyslipidemia with a 2 hour 75 g oral glucose tolerance test and fasting lipid profile upon diagnosis and also undergo repeat screening every 2-5 years and every 2 years, respectively. Although a hemoglobin A1C and/or fasting glucose are widely used screening tests for diabetes, both the American College of Obstetricians and Gynecologists and the Endocrine Society preferentially recommend the 2 hour oral glucose tolerance test in women with polycystic ovary syndrome as a superior indicator of impaired glucose tolerance/diabetes mellitus. However, we found that gynecologists underutilize current recommendations for metabolic screening in women with polycystic ovary syndrome. In an online survey study targeting American College of Obstetricians and Gynecologists fellows and junior fellows, 22.3% of respondents would not order any screening test at the initial visit for at least 50% of their patients with polycystic ovary syndrome. The most common tests used to screen for impaired glucose tolerance in women with polycystic ovary syndrome were hemoglobin A1C (51.0%) and fasting glucose (42.7%). Whereas 54.1% would order a fasting lipid profile in at least 50% of their polycystic ovary syndrome patients, only 7% of respondents order a 2 hour oral glucose tolerance test. We therefore call for increased efforts to encourage obstetrician-gynecologists to address metabolic abnormalities in their patients with polycystic ovary syndrome. Such efforts should include education of physicians early in their careers, at the medical student and resident level. Efforts should also include implementation of continuing medical education activities, both locally and at the national level, to improve understanding of the metabolic implications of polycystic ovary syndrome. Electronic medical record systems should be utilized to generate prompts for appropriate screening tests in patients with a diagnosis of polycystic ovary syndrome. Because obstetrician-gynecologists may be the only physicians seen by many polycystic ovary syndrome patients, particularly those in their young reproductive years, such interventions could effectively promote optimal preventative health care and early diagnosis of metabolic comorbidities in these at-risk women. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Random plasma glucose in serendipitous screening for glucose intolerance: screening for impaired glucose tolerance study 2.

    PubMed

    Ziemer, David C; Kolm, Paul; Foster, Jovonne K; Weintraub, William S; Vaccarino, Viola; Rhee, Mary K; Varughese, Rincy M; Tsui, Circe W; Koch, David D; Twombly, Jennifer G; Narayan, K M Venkat; Phillips, Lawrence S

    2008-05-01

    With positive results from diabetes prevention studies, there is interest in convenient ways to incorporate screening for glucose intolerance into routine care and to limit the need for fasting diagnostic tests. The aim of this study is to determine whether random plasma glucose (RPG) could be used to screen for glucose intolerance. This is a cross-sectional study. The participants of this study include a voluntary sample of 990 adults not known to have diabetes. RPG was measured, and each subject had a 75-g oral glucose tolerance test several weeks later. Glucose intolerance targets included diabetes, impaired glucose tolerance (IGT), and impaired fasting glucose(110) (IFG(110); fasting glucose, 110-125 mg/dl, and 2 h glucose < 140 mg/dl). Screening performance was measured by area under receiver operating characteristic curves (AROC). Mean age was 48 years, and body mass index (BMI) was 30.4 kg/m(2); 66% were women, and 52% were black; 5.1% had previously unrecognized diabetes, and 24.0% had any "high-risk" glucose intolerance (diabetes or IGT or IFG(110)). The AROC was 0.80 (95% CI 0.74-0.86) for RPG to identify diabetes and 0.72 (0.68-0.75) to identify any glucose intolerance, both highly significant (p < 0.001). Screening performance was generally consistent at different times of the day, regardless of meal status, and across a range of risk factors such as age, BMI, high density lipoprotein cholesterol, triglycerides, and blood pressure. RPG values should be considered by health care providers to be an opportunistic initial screening test and used to prompt further evaluation of patients at risk of glucose intolerance. Such "serendipitous screening" could help to identify unrecognized diabetes and prediabetes.

  7. Fifty years of newborn screening.

    PubMed

    Wilcken, Bridget; Wiley, Veronica

    2015-01-01

    Newborn screening has evolved fast following recent advances in diagnosis and treatment of disease, particularly the development of multiplex testing and applications of molecular testing. Formal evidence of benefit from newborn screening has been largely lacking, due to the rarity of individual disorders. There are wide international differences in the choice of disorders screened, and ethical issues in both screening and not screening are apparent. More evidence is needed about benefit and harm of screening for specific disorders and renewed discussion about the basic aims of newborn screening must be undertaken. © 2015 The Authors. Journal of Paediatrics and Child Health © 2015 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  8. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...

  9. Comparative study of HbA1c and fasting plasma glucose vs the oral glucose tolerance test for diagnosis of diabetes in people with tuberculosis.

    PubMed

    Aftab, H; Ambreen, A; Jamil, M; Garred, P; Petersen, J H; Nielsen, S D; Bygbjerg, I C; Christensen, D L

    2017-06-01

    To compare HbA 1c and fasting plasma glucose assessment, with the 2-h oral glucose tolerance test as reference, in screening for diabetes in people with turberculosis. Individuals (N=268) with newly diagnosed smear-positive tuberculosis were screened for diabetes at a tertiary hospital in Lahore, Pakistan. Diabetes diagnosis was based on WHO criteria: thresholds were ≥48 mmol/mol (≥6.5%) for HbA 1c and ≥7.0mmol/l for fasting plasma glucose. The proportion of participants diagnosed with diabetes was 4.9% (n =13) by oral glucose tolerance test, while 11.9% (n =32) and 14.6% (n =39) were diagnosed with diabetes using HbA 1c and fasting plasma glucose criteria, respectively. The area under the receiver-operating characteristic curve was 0.79 (95% CI 0.64 to 0.94) for HbA 1c and 0.61 (95% CI 0.50 to 0.73) for fasting plasma glucose, with a borderline significant difference between the two tests (P=0.07). HbA 1c and fasting plasma glucose performed equally in terms of diagnosing new diabetes cases in individuals with tuberculosis, but the proportion of participants falsely classified as positive was higher for fasting plasma glucose. This may be explained by acute blood glucose fluctuations when using fasting plasma glucose. HbA 1c may be a more reliable test in individuals with transient hyperglycaemia. © 2017 Diabetes UK.

  10. [Screening for diabetes in France: data from the 2000-2001 cohort of the national medical insurance system].

    PubMed

    Hirtzlin, I; Fagot-Campagna, A; Girard-Le Gallo, I; Vallier, N; Poutignat, N; Weill, A; Le Laidier, S

    2004-04-01

    Type 2 diabetes mellitus may go undiagnosed for several Years while complications are silently developing. In France, from 2 to 3.7% of adults aged 35-65 are unaware they have diabetes. Nevertheless fasting serum glucose is a simple diagnostic test. We described people who underwent opportunist diabetes screening (serum glucose) within 2 Years (2000-2001). We used the administrative EPAS cohort from the employee National Health Insurance System which covers 70% of the total population in France. The data are based on reimbursements of glucose testing and hospitalization among people who did not received reimbursements of treatment for diabetes but used medical services during the 2 Years. The opportunistic screening rate within 2 Years was 48.6% overall and increased with age. Among those 45 Years old or older, it was 71.2%. The screening rate was higher among women than men. Opportunistic screening for diabetes is commonly practised in France, despite the lack of official guidelines. Several hypotheses may explain the discrepancy between common opportunist screening and high prevalence of undiagnosed diabetes: 1). undiagnosed diabetes is mostly present in people who do not use medical services; 2). opportunistic screening is not performed among the most at-risk population; 3). testing is not performed on fasting samples or results are neglected; 4). results of testing are overlooked by doctors/patients; 5). epidemiological studies based on self-report of diagnosis and only one testing overestimate undiagnosed diabetes.

  11. Gestational diabetes mellitus screening, management and outcomes in the Cook Islands.

    PubMed

    Aung, Yin Yin May; Sowter, Martin; Kenealy, Timothy; Herman, Josephine; Ekeroma, Alec

    2015-04-17

    To describe current practices for screening for gestational diabetes mellitus in the Cook Islands and consider the implications of alternative screening strategies. Eligible women had antenatal care from January 2009 to December 2012. A non-fasting 50 g glucose challenge between 24 and 28 weeks gestation (positive if 1-hour glucose greater than or equal to 7.8 mmol/L) was followed by a 75 g oral glucose tolerance test (gestational diabetes mellitus diagnosed if fasting glucose greater than or equal to 5.2 mmol/L or 2-hour glucose greater than or equal to 8.0 mmol/L; pregnancy impaired glucose tolerance if positive screen and negative diagnostic test). Uptake of the screening programme rose from 49.0% to 99.6% by the end of the study period. 646 women had a glucose challenge; for 186/646 (28.8%) the challenge was positive; 183 had an oral glucose tolerance test; 89/646 (13.8%) had pregnancy impaired glucose tolerance; 94/646 (13.9%) had gestational diabetes mellitus. Median maternal weight gain was 6 kg (gestational diabetes mellitus) and 10 kg (normal glucose tolerance); caesarean section rates were 25% and 11% respectively; baby birthweights were not significantly different. 59 women with gestational diabetes mellitus had a post-natal glucose tolerance test at their 6-week check and 21 (35.6%) had diabetes confirmed. The gestational diabetes mellitus screening programme has a high uptake and current management appears effective in reducing maternal and fetal weight gain. A proposed new screening programme is outlined.

  12. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues to the Kidney Inhibition Swab (KIS(TM)) from the Fast Antimicrobial Screen Test. A high dose of penicillin G procaine relative to a label dose is commonly used ...

  13. Introduction to Flight Test Engineering (Introduction aux techniques des essais en vol)

    DTIC Science & Technology

    2005-07-01

    or aircraft parameters • Calculations in the frequency domain ( Fast Fourier Transform) • Data analysis with dedicated software for: • Signal...density Fast Fourier Transform Transfer function analysis Frequency response analysis Etc. PRESENTATION Color/black & white Display screen...envelope by operating the airplane at increasing ranges - representing increasing risk - of engine operation, airspeeds both fast and slow, altitude

  14. Utility of antenatal clinical factors for prediction of postpartum outcomes in women with gestational diabetes mellitus (GDM).

    PubMed

    Ingram, Emily R; Robertson, Iain K; Ogden, Kathryn J; Dennis, Amanda E; Campbell, Joanne E; Corbould, Anne M

    2017-06-01

    Gestational diabetes mellitus (GDM) is associated with life-long increased risk of type 2 diabetes: affected women are advised to undergo oral glucose tolerance testing (OGTT) at 6-12 weeks postpartum, then glucose screening every 1-3 years. We investigated whether in women with GDM, antenatal clinical factors predicted postpartum abnormal glucose tolerance and compliance with screening. In women with GDM delivering 2007 to mid-2009 in a single hospital, antenatal/obstetric data and glucose tests at 6-12 weeks postpartum and during 5.5 years post-pregnancy were retrospectively collected. Predictors of return for testing and abnormal glucose tolerance were identified using multivariate analysis. Of 165 women, 117 (70.9%) returned for 6-12 week postpartum OGTT: 23 (19.6%) were abnormal. Smoking and parity, independent of socioeconomic status, were associated with non-return for testing. Fasting glucose ≥5.4 mmol/L on pregnancy OGTT predicted both non-return for testing and abnormal OGTT. During 5.5 years post-pregnancy, 148 (89.7%) women accessed glucose screening: nine (6.1%) developed diabetes, 33 (22.3%) had impaired fasting glucose / impaired glucose tolerance. Predictors of abnormal glucose tolerance were fasting glucose ≥5.4 mmol/L and 2-h glucose ≥9.3 mmol/L on pregnancy OGTT (~2.5-fold increased risk), and polycystic ovary syndrome (~3.4 fold increased risk). Risk score calculation, based on combined antenatal factors, did not improve predictions. Antenatal clinical factors were modestly predictive of return for testing and abnormal glucose tolerance post-pregnancy in women with GDM. Risk score calculations were ineffective in predicting outcomes: risk scores developed in other populations require validation. Ongoing glucose screening is indicated for all women with GDM. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  15. 77 FR 16846 - Published Privacy Impact Assessments on the Web

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ... Security Advanced Research Projects Agency (HSARPA), S&T Directorate seeks to develop physiological and behavioral screening technologies that will enable security officials to test the effectiveness of current... FAST research is adding a new type of research, the Passive Methods for Precision Behavioral Screening...

  16. Ultrasensitive Immunochromatographic Strip for Fast Screening of 27 Sulfonamides in Honey and Pork Liver Samples Based on a Monoclonal Antibody.

    PubMed

    Chen, Yanni; Guo, Lingling; Liu, Liqiang; Song, Shanshan; Kuang, Hua; Xu, Chuanlai

    2017-09-20

    Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC 50 ) values ranging from 0.15 to 15.38 μg/L. In particular, the IC 50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 μg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 μg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.

  17. MRSA Screening

    MedlinePlus

    ... they are isolated in a culture . These additional research tests can identify the type and subtype of S. aureus ... 14. Case, M. (2006 March 15). Fast staph test limits spread, at a high price. Post-gazette.com [On-line information]. Available online at ...

  18. Screening obese children and adolescents for prediabetes and/or type 2 diabetes in pediatric practices: a validation study.

    PubMed

    Brar, Preneet C; Mengwall, Lisa; Franklin, Bonita H; Fierman, Arthur H

    2014-07-01

    Increased prevalence of type 2 diabetes mellitus (T2DM) makes it important for pediatricians to use effective screening tools for risk assessment of prediabetes/T2DM in children. Children (n = 149) who had an oral glucose tolerance test (OGTT) and glycated hemoglobin (HbA1c) were studied. American Diabetes Association recommended screening criteria-HbA1c ≥5.7% and fasting plasma glucose (FPG) ≥100 mg/dL-were compared against OGTT. The homeostatic model assessment of insulin resistance (HOMA-IR), a mathematical index derived from fasting insulin and glucose, was compared with OGTT. We studied whether combining screening tests (HbA1c and fasting glucose or HbA1c and HOMA-IR) improved accuracy of prediction of the OGTT. HbA1c of ≥5.7% had a sensitivity of 75% and specificity of 57% when compared with the OGTT. Combining screening tests (HbA1c ≥5.7% and FPG ≥100 mg/dL; HbA1c ≥5.7% and HOMA-IR ≥3.4) resulted in improved sensitivity (95.5% for each), with the HbA1c-FPG doing better than the HbA1c-HOMA-IR combination in terms of ability to rule out prediabetes (likelihood ratio [LR]) negative. 0.07 vs 0.14). HbA1c of ≥5.7% provided fair discrimination of glucose tolerance compared with the OGTT. The combination of HbA1c and FPG is a useful method for identifying children who require an OGTT. © The Author(s) 2014.

  19. What Tests Might I Need during Pregnancy?

    MedlinePlus

    ... having twins—you should discuss this with your health care provider get a test for blood glucose earlier in your pregnancy. Group ... challenge screening is above a certain level, your health care provider may order this test. You will fast for at least 8 hours ...

  20. Microplate Bioassay for Determining Substrate Selectivity of "Candida rugosa" Lipase

    ERIC Educational Resources Information Center

    Wang, Shi-zhen; Fang, Bai-shan

    2012-01-01

    Substrate selectivity of "Candida rugosa" lipase was tested using "p"-nitrophenyl esters of increasing chain length (C[subscript 1], C[subscript 7], C[subscript 15]) using the high-throughput screening method. A fast and easy 96-well microplate bioassay was developed to help students learn and practice biotechnological specificity screen. The…

  1. Diabetes Mellitus: Screening and Diagnosis.

    PubMed

    Pippitt, Karly; Li, Marlana; Gurgle, Holly E

    2016-01-15

    Diabetes mellitus is one of the most common diagnoses made by family physicians. Uncontrolled diabetes can lead to blindness, limb amputation, kidney failure, and vascular and heart disease. Screening patients before signs and symptoms develop leads to earlier diagnosis and treatment, but may not reduce rates of end-organ damage. Randomized trials show that screening for type 2 diabetes does not reduce mortality after 10 years, although some data suggest mortality benefits after 23 to 30 years. Lifestyle and pharmacologic interventions decrease progression to diabetes in patients with impaired fasting glucose or impaired glucose tolerance. Screening for type 1 diabetes is not recommended. The U.S. Preventive Services Task Force recommends screening for abnormal blood glucose and type 2 diabetes in adults 40 to 70 years of age who are overweight or obese, and repeating testing every three years if results are normal. Individuals at higher risk should be considered for earlier and more frequent screening. The American Diabetes Association recommends screening for type 2 diabetes annually in patients 45 years and older, or in patients younger than 45 years with major risk factors. The diagnosis can be made with a fasting plasma glucose level of 126 mg per dL or greater; an A1C level of 6.5% or greater; a random plasma glucose level of 200 mg per dL or greater; or a 75-g two-hour oral glucose tolerance test with a plasma glucose level of 200 mg per dL or greater. Results should be confirmed with repeat testing on a subsequent day; however, a single random plasma glucose level of 200 mg per dL or greater with typical signs and symptoms of hyperglycemia likely indicates diabetes. Additional testing to determine the etiology of diabetes is not routinely recommended.

  2. [The influence of age, place of living, education and number of earlier pregnancies on attendance of pregnant women to screening tests--questionnaire study].

    PubMed

    Kiałka, Marta; Czyzewicz, Małgorzata; Zuk, Małgorzata; Milewicz, Tomasz; Krzyczkowska-Sendrakowska, Magdalena; Pietrus, Miłosz

    2015-01-01

    The aim of this study was to assess attendance at the screening programme in pregnancy and the influence of age, number of past pregnancies, level of education and place of residence on the attendance. Our study was performed on the basis of an anonymous questionnaire handed out 543 women aged 16-45, on the third day of their puerperal, in one of the five obstetric wards in southern Poland. The questionnaire contained questions about participation in recommended for pregnant women screening tests such as: fasting blood glucose level measurement, oral glucose tolerance test, blood type test, measurement of hepatitis B surface antigen and antibodies to VDRL, Rubella, Toxoplasma gondii, hepatitis C virus at least once during pregnancy. The highest attendance rate was related with blood type test, whereas the lowest was related with measurement of antibodies to hepatitis C virus (95.6% vs 22.7%, p < 0.001). A very low percentage of pregnant patients measured Rubella antibodies (29.1%). A larger proportion of the respondents checked antibodies against Toxoplasma gondii (41.6%). The attendance at fasting blood glucose level was 66.9 % and at oral glucose tolerance test was 63.7%. The attendance according as age, place of living, number of past pregnancies and level of education was described in detail. Despite current recommendations of Polish Gynecological Society and the ordinance of polish Minister of Health the percentage of women participating in screening tests during pregnancy is still insufficient. Age, place of residence and education remain strong factors influencing attendance at the screening programme in pregnancy.

  3. Evaluation of a standard test method for screening fuels in soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorini, S.S.; Schabron, J.F.

    1996-12-31

    A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less

  4. Simple and fast screening of G-quadruplex ligands with electrochemical detection system.

    PubMed

    Fan, Qiongxuan; Li, Chao; Tao, Yaqin; Mao, Xiaoxia; Li, Genxi

    2016-11-01

    Small molecules that may facilitate and stabilize the formation of G-quadruplexes can be used for cancer treatments, because the G-quadruplex structure can inhibit the activity of telomerase, an enzyme over-expressed in many cancer cells. Therefore, there is considerable interest in developing a simple and high-performance method for screening small molecules binding to G-quadruplex. Here, we have designed a simple electrochemical approach to screen such ligands based on the fact that the formation and stabilization of G-quadruplex by ligand may inhibit electron transfer of redox species to electrode surface. As a proof-of-concept study, two types of classical G-quadruplex ligands, TMPyP4 and BRACO-19, are studied in this work, which demonstrates that this method is fast and robust and it may be applied to screen G-quadruplex ligands for anticancer drugs testing and design in the future. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Examining the occurrence of residues of flunixin meglumine in cull dairy cows by use of the flunixin cull cow survey.

    PubMed

    Deyrup, Cynthia L; Southern, Kristal J; Cornett, Julie A; Shultz, Craig E; Cera, Deborah A

    2012-07-15

    To determine whether cull dairy cows with signs of certain clinical conditions, termed suspect, are more likely than healthy-appearing cull dairy cows to have violative concentrations of flunixin meglumine in their tissues at slaughter. Cross-sectional study. 961 cull dairy cows. Suspect cull dairy cows were selected from 21 beef slaughter establishments with a high production volume of dairy cows, and kidney and liver tissues were collected for screening. Kidney tissues were screened for antibiotics and sulfonamides with the fast antimicrobial screening test (FAST). Liver tissues were screened for flunixin meglumine with an ELISA, and quantitative analysis of ELISA-positive samples was performed with high-performance liquid chromatography. During the same time period, liver tissues from 251 healthy-appearing cull dairy cows were collected for the Food Safety and Inspection Service National Residue Program Scheduled Sampling Plan, but were screened only for flunixin meglumine. Of 710 suspect cull dairy cows, 50 (7.04%) had liver tissue flunixin concentrations higher than the flunixin tolerance concentration (0.125 ppm). Thirty-one of 168 (18.45%) FAST-positive and 19 of 542 (3.51%) FAST-negative suspect cull dairy cows had violative tissue flunixin concentrations. Two of the 251 (0.80%) healthy-appearing cull dairy cows had violative tissue flunixin concentrations. Suspect cull dairy cows, especially those that were also FAST positive, had a significantly higher incidence of violative tissue flunixin concentrations than healthy-appearing cull dairy cows at slaughter. Targeted sampling plans for flunixin meglumine in suspect dairy cows can help to support more efficient use of resources and further safeguard the nation's food supply.

  6. Evaluation of the Premi Test and comparison with the One-Plate Test for the detection of antimicrobials in kidney.

    PubMed

    Cantwell, H; O'Keeffe, M

    2006-02-01

    The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.

  7. Reverse Fluorescence Enhancement and Colorimetric Bimodal Signal Readout Immunochromatography Test Strip for Ultrasensitive Large-Scale Screening and Postoperative Monitoring.

    PubMed

    Yao, Yingyi; Guo, Weisheng; Zhang, Jian; Wu, Yudong; Fu, Weihua; Liu, Tingting; Wu, Xiaoli; Wang, Hanjie; Gong, Xiaoqun; Liang, Xing-Jie; Chang, Jin

    2016-09-07

    Ultrasensitive and quantitative fast screening of cancer biomarkers by immunochromatography test strip (ICTS) is still challenging in clinic. The gold nanoparticles (NPs) based ICTS with colorimetric readout enables a quick spectrum screening but suffers from nonquantitative performance; although ICTS with fluorescence readout (FICTS) allows quantitative detection, its sensitivity still deserves more efforts and attentions. In this work, by taking advantages of colorimetric ICTS and FICTS, we described a reverse fluorescence enhancement ICTS (rFICTS) with bimodal signal readout for ultrasensitive and quantitative fast screening of carcinoembryonic antigen (CEA). In the presence of target, gold NPs aggregation in T line induced colorimetric readout, allowing on-the-spot spectrum screening in 10 min by naked eye. Meanwhile, the reverse fluorescence enhancement signal enabled more accurately quantitative detection with better sensitivity (5.89 pg/mL for CEA), which is more than 2 orders of magnitude lower than that of the conventional FICTS. The accuracy and stability of the rFICTS were investigated with more than 100 clinical serum samples for large-scale screening. Furthermore, this rFICTS also realized postoperative monitoring by detecting CEA in a patient with colon cancer and comparing with CT imaging diagnosis. These results indicated this rFICTS is particularly suitable for point-of-care (POC) diagnostics in both resource-rich and resource-limited settings.

  8. Validity of the Miller forensic assessment of symptoms test in psychiatric inpatients.

    PubMed

    Veazey, Connie H; Wagner, Alisha L; Hays, J Ray; Miller, Holly A

    2005-06-01

    This study investigated the validity of the Miller Forensic Assessment of Symptoms Test (M-FAST), a brief measure of malingering, in an inpatient psychiatric sample of 70. Among those patients who also completed the Personality Assessment Inventory (N=44), Total M-FAST score was related in the expected directions to the Personality Assessment Inventory validity scales and indexes, providing evidence for concurrent validity of the M-FAST. With the PAI malingering index used as a criterion, we examined the diagnostic efficiency of the M-FAST and found a cut score of 8 represented the best balance of sensitivity, specificity, positive predictive power, and negative predictive power. Based on this cut-score of 8, 16% of the population was classified as malingering. The M-FAST appears to be an excellent rapid screen for symptom exaggeration in this population and setting.

  9. Fasting glucose measurement as a potential first step screening for glucose metabolism abnormalities in women with anovulatory polycystic ovary syndrome.

    PubMed

    Veltman-Verhulst, Susanne M; Goverde, Angelique J; van Haeften, Timon W; Fauser, Bart C J M

    2013-08-01

    Is routine screening by oral glucose tolerance test (OGTT) needed for all women with polycystic ovary syndrome (PCOS)? Screening for glucose metabolism abnormalities of PCOS patients by an OGTT could potentially be limited to patients who present with a fasting glucose concentration between 6.1 and 7.0 mmol/l only. Women with PCOS are at increased risk of developing diabetes. This study proposes a stepwise screening strategy for (pre)diabetes for PCOS patients based on risk stratification by fasting plasma glucose. A cross-sectional study of 226 women diagnosed with anovulatory PCOS. A consecutive series of 226 patients, diagnosed with PCOS at the University Medical Centre Utrecht, the Netherlands, were screened for glucose metabolism abnormalities by OGTT (75 g glucose load). The majority of the 226 women (mean age: 29.6 ± 4.3 years; BMI: 27.3 ± 6.7 kg/m(2); 81% Caucasian) presented with a normal OGTT (169 women (75%)). Of the 57 (25%) women presenting with mild to moderate glucose abnormalities, 53 (93%) could be identified by fasting glucose concentrations only. Diabetes was diagnosed in a total of eight women (3.5%). In six women, the diagnosis was based on fasting glucose >7.0 mmol/l. The other two cases of diabetes initially presented with fasting glucose between 6.1 and 7.0 mmol/l and were diagnosed by OGTT assessment. No women diagnosed with diabetes presented with fasting glucose levels below 6.1 mmol/l. We therefore conclude that all diabetes patients could potentially be found by initial fasting glucose assessment followed by OGTT only in patients with fasting glucose between 6.1 and 7.0 mmol/l. Before general implementation can be advised, this screening algorithm should be validated in a prospective study of a similar or greater number of PCOS women. Our study comprised of a mostly Caucasian (81%) population, therefore generalization to other ethnic populations should be done with caution. No external finance was involved in this study. B.C.J.M.F. has received fees and grant support from the following companies (in alphabetic order); Andromed, Ardana, Ferring, Genovum, Merck Serono, MSD, Organon, Pantharei Bioscience, PregLem, Schering, Schering Plough, Serono and Wyeth. A.J.G. has received fees from Abbott, Bayer Schering and IBSA. T.W.H. has received fees from Merck, Sharpe & Dohme, GlaxoSmithKline, NovoNordisk and Eli Lilly. The authors declare complete independence from funders. NCT00821379.

  10. Accurate screening for insulin resistance in PCOS women using fasting insulin concentrations.

    PubMed

    Lunger, Fabian; Wildt, Ludwig; Seeber, Beata

    2013-06-01

    The aims of this cross-sectional study were to evaluate the relative agreement of both static and dynamic methods of diagnosing IR in women with polycystic ovary syndrome (PCOS) and to suggest a simple screening method for IR. All participants underwent serial blood draws for hormonal profiling and lipid assessment, a 3 h, 75 g load oral glucose tolerance test (OGTT) with every 15 min measurements of glucose and insulin, and an ACTH stimulation test. The prevalence of IR ranged from 12.2% to 60.5%, depending on the IR index used. Based on largest area under the curve on receiver operating curve (ROC) analyses, the dynamic indices outperformed the static indices with glucose to insulin ratio and fasting insulin (fInsulin) demonstrating the best diagnostic properties. Applying two cut-offs representing fInsulin extremes (<7 and >13 mIU/l, respectively) gave the diagnosis in 70% of the patients with high accuracy. Currently utilized indices for assessing IR give highly variable results in women with PCOS. The most accurate indices based on dynamic testing can be time-consuming and labor-intensive. We suggest the use of fInsulin as a simple screening test, which can reduce the number of OGTTs needed to routinely assess insulin resistance in women with PCOS.

  11. Use of the Falcon assay screening test--enzyme-linked immunosorbent assay (FAST-ELISA) and the enzyme-linked immunoelectrotransfer blot (EITB) to determine the prevalence of human fascioliasis in the Bolivian Altiplano.

    PubMed

    Hillyer, G V; Soler de Galanes, M; Rodriguez-Perez, J; Bjorland, J; Silva de Lagrava, M; Ramirez Guzman, S; Bryan, R T

    1992-05-01

    A collaborative study between the University of Puerto Rico School of Medicine, the Centers for Disease Control, the Bolivian Ministry of Health, and private voluntary organizations (Foster Parents Plan International and Danchurchaid) working in Bolivia has identified a region in the northwestern Altiplano of Bolivia near Lake Titicaca as harboring the highest prevalence of human fascioliasis in the world reported to date. Two serologic techniques (the Falcon assay screening test-enzyme-linked immunosorbent assay [FAST-ELISA] and the enzyme-linked immunoelectrotransfer blot [EITB]) were used in the determination of its prevalence. One hundred serum samples and 73 stool samples were obtained from Aymara Indians from Corapata, Bolivia. Antibody absorbance levels to Fasciola hepatica excretion-secretion antigens were compared with EITB banding patterns using the same antigen preparation. A positive FAST-ELISA result was defined as an absorbance value greater than the mean plus three standard deviations of two sets of normal negative controls (Puerto Rican and Bolivian). Using this criterion, 53 of 100 sera tested were found positive by this technique. Within this group, 19 (95%) of 20 individuals who were parasite positive were also positive by FAST-ELISA. An additional 24 individuals who were negative for F. hepatica eggs and 10 individuals for whom no specimens were received were also positive by FAST-ELISA. Among the 53 individuals negative for F. hepatica eggs, 29 were also negative by FAST-ELISA. The EITB analysis of the sera from confirmed infected individuals revealed at least three F. hepatica (Fh) bands with molecular weights of 12, 17, and 63 kD, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  13. Receipt of Glucose Testing and Performance of Two US Diabetes Screening Guidelines, 2007–2012

    PubMed Central

    Bullard, Kai McKeever; Ali, Mohammed K.; Imperatore, Giuseppina; Geiss, Linda S.; Saydah, Sharon H.; Albu, Jeanine B.; Cowie, Catherine C.; Sohler, Nancy; Albright, Ann; Gregg, Edward W.

    2015-01-01

    Background Screening guidelines are used to help identify prediabetes and diabetes before implementing evidence-based prevention and treatment interventions. We examined screening practices benchmarking against two US guidelines, and the capacity of each guideline to identify dysglycemia. Methods Using 2007–2012 National Health and Nutrition Examination Surveys, we analyzed nationally-representative, cross-sectional data from 5,813 fasting non-pregnant adults aged ≥20 years without self-reported diabetes. We examined proportions of adults eligible for diagnostic glucose testing and those who self-reported receiving testing in the past three years, as recommended by the American Diabetes Association (ADA) and the US Preventive Services Task Force (USPSTF-2008) guidelines. For each screening guideline, we also assessed sensitivity, specificity, and positive (PPV) and negative predictive values in identifying dysglycemia (defined as fasting plasma glucose ≥100 mg/dl or hemoglobin A1c ≥5.7%). Results In 2007–2012, 73.0% and 23.7% of US adults without diagnosed diabetes met ADA and USPSTF-2008 criteria for screening, respectively; and 91.5% had at least one major risk factor for diabetes. Of those ADA- or USPSTF-eligible adults, about 51% reported being tested within the past three years. Eligible individuals not tested were more likely to be lower educated, poorer, uninsured, or have no usual place of care compared to tested eligible adults. Among adults with ≥1 major risk factor, 45.7% reported being tested, and dysglycemia yields (i.e., PPV) ranged from 45.8% (high-risk ethnicity) to 72.6% (self-reported prediabetes). ADA criteria and having any risk factor were more sensitive than the USPSTF-2008 guideline (88.8–97.7% vs. 31.0%) but less specific (13.5–39.7% vs. 82.1%) in recommending glucose testing, resulting in lower PPVs (47.7–54.4% vs. 58.4%). Conclusion Diverging recommendations and variable performance of different guidelines may be impeding national diabetes prevention and treatment efforts. Efforts to align screening recommendations may result in earlier identification of adults at high risk for prediabetes and diabetes. PMID:25928306

  14. Human recombinant beta-secretase immobilized enzyme reactor for fast hits' selection and characterization from a virtual screening library.

    PubMed

    De Simone, Angela; Mancini, Francesca; Cosconati, Sandro; Marinelli, Luciana; La Pietra, Valeria; Novellino, Ettore; Andrisano, Vincenza

    2013-01-25

    In the present work, a human recombinant BACE1 immobilized enzyme reactor (hrBACE1-IMER) has been applied for the sensitive fast screening of 38 compounds selected through a virtual screening approach. HrBACE1-IMER was inserted into a liquid chromatograph coupled with a fluorescent detector. A fluorogenic peptide substrate (M-2420), containing the β-secretase site of the Swedish mutation of APP, was injected and cleaved in the on-line HPLC-hrBACE1-IMER system, giving rise to the fluorescent product. The compounds of the library were tested for their ability to inhibit BACE1 in the immobilized format and to reduce the area related to the chromatographic peak of the fluorescent enzymatic product. The results were validated in solution by using two different FRET methods. Due to the efficient virtual screening methodology, more than fifty percent of the selected compounds showed a measurable inhibitory activity. One of the most active compound (a bis-indanone derivative) was characterized in terms of IC(50) and K(i) determination on the hrBACE1-IMER. Thus, the hrBACE1-IMER has been confirmed as a valid tool for the throughput screening of different chemical entities with potency lower than 30μM for the fast hits' selection and for mode of action determination. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Who attends a UK diabetes screening programme? Findings from the ADDITION-Cambridge study.

    PubMed

    Sargeant, L A; Simmons, R K; Barling, R S; Butler, R; Williams, K M; Prevost, A T; Kinmonth, A L; Wareham, N J; Griffin, S J

    2010-09-01

    One of the factors influencing the cost-effectiveness of population screening for Type 2 diabetes may be uptake. We examined attendance and practice- and individual-level factors influencing uptake at each stage of a diabetes screening programme in general practice. A stepwise screening programme was undertaken among 135, 825 people aged 40-69 years without known diabetes in 49 general practices in East England. The programme included a score based on routinely available data (age, sex, body mass index and prescribed medication) to identify those at high risk, who were offered random capillary blood glucose (RBG) and glycosylated haemoglobin tests. Those screening positive were offered fasting capillary blood glucose (FBG) and confirmatory oral glucose tolerance tests (OGTT). There were 33 539 high-risk individuals invited for a RBG screening test; 24 654 (74%) attended. Ninety-four per cent attended the follow-up FBG test and 82% the diagnostic OGTT. Seventy per cent of individuals completed the screening programme. Practices with higher general practitioner staff complements and those located in more deprived areas had lower uptake for RBG and FBG tests. Male sex and a higher body mass index were associated with lower attendance for RBG testing. Older age, prescription of antihypertensive medication and a higher risk score were associated with higher attendance for FBG and RBG tests. High attendance rates can be achieved by targeted stepwise screening of individuals assessed as high risk by data routinely available in general practice. Different strategies may be required to increase initial attendance, ensure completion of the screening programme, and reduce the risk that screening increases health inequalities.

  16. Combined use of fasting plasma glucose and glycated hemoglobin A1c in a stepwise fashion to detect undiagnosed diabetes mellitus.

    PubMed

    Nakagami, Tomoko; Tominaga, Makoto; Nishimura, Rimei; Daimon, Makoto; Oizumi, Toshihide; Yoshiike, Nobuo; Tajima, Naoko

    2007-09-01

    Type 2 diabetes mellitus (DM) is a common and serious condition related with considerable morbidity. Screening for DM is one strategy for reducing this burden. In Japan National Diabetes Screening Program (JNDSP) guideline, the combined use of fasting plasma glucose (FPG) and glycated hemoglobin A1c (HbA1c) in a stepwise fashion has been recommended to identify the group of people needing life-style counseling or medical care. However, the efficacy of this program has not been fully evaluated, as an oral glucose tolerance test (OGTT) is not mandatory in the guideline. The aim of this study was to assess the validity of the screening test scenario, in which an OGTT would be applied to people needing life-style counseling or medical care on this guideline: FPG 110-125 mg/dl and HbA1c over 5.5%. Subjects were 1,726 inhabitants without a previous history of DM in the Funagata study, which is a population-based survey conducted in Yamagata prefecture to clarify the risk factors, related conditions, and consequences of DM. DM was diagnosed according to the 1999 World Health Organization criteria. The prevalence of undiagnosed DM was 6.6%. The tested screening scenario gave a sensitivity of 55.3%, a specificity of 98.4%, a positive predictive value of 70.8%, and a negative predictive value of 96.9% for undiagnosed DM. In conclusion, the screening test scenario, in which an OGTT would be followed by the combined use of FPG and HbA1c in a stepwise fashion according to the JNDSP guideline, was not effective in identifying people with undiagnosed DM.

  17. An experience of qualified preventive screening: shiraz smart screening software.

    PubMed

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  18. Novel method for screening of enteric film coatings properties with magnetic resonance imaging.

    PubMed

    Dorożyński, Przemysław; Jamróz, Witold; Niwiński, Krzysztof; Kurek, Mateusz; Węglarz, Władysław P; Jachowicz, Renata; Kulinowski, Piotr

    2013-11-18

    The aim of the study is to present the concept of novel method for fast screening of enteric coating compositions properties without the need of preparation of tablets batches for fluid bed coating. Proposed method involves evaluation of enteric coated model tablets in specially designed testing cell with application of MRI technique. The results obtained in the testing cell were compared with results of dissolution studies of mini-tablets coated in fluid bed apparatus. The method could be useful in early stage of formulation development for screening of film coating properties that will shorten and simplify the development works. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Developing a Screening Algorithm for Type II Diabetes Mellitus in the Resource-Limited Setting of Rural Tanzania.

    PubMed

    West, Caroline; Ploth, David; Fonner, Virginia; Mbwambo, Jessie; Fredrick, Francis; Sweat, Michael

    2016-04-01

    Noncommunicable diseases are on pace to outnumber infectious disease as the leading cause of death in sub-Saharan Africa, yet many questions remain unanswered with concern toward effective methods of screening for type II diabetes mellitus (DM) in this resource-limited setting. We aim to design a screening algorithm for type II DM that optimizes sensitivity and specificity of identifying individuals with undiagnosed DM, as well as affordability to health systems and individuals. Baseline demographic and clinical data, including hemoglobin A1c (HbA1c), were collected from 713 participants using probability sampling of the general population. We used these data, along with model parameters obtained from the literature, to mathematically model 8 purposed DM screening algorithms, while optimizing the sensitivity and specificity using Monte Carlo and Latin Hypercube simulation. An algorithm that combines risk assessment and measurement of fasting blood glucose was found to be superior for the most resource-limited settings (sensitivity 68%, sensitivity 99% and cost per patient having DM identified as $2.94). Incorporating HbA1c testing improves the sensitivity to 75.62%, but raises the cost per DM case identified to $6.04. The preferred algorithms are heavily biased to diagnose those with more severe cases of DM. Using basic risk assessment tools and fasting blood sugar testing in lieu of HbA1c testing in resource-limited settings could allow for significantly more feasible DM screening programs with reasonable sensitivity and specificity. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  20. Cell-based approaches for screening and prioritization of chemicals that may cause developmental neurotoxicity

    EPA Science Inventory

    The National Academies report on Toxicity Testing in the 21st Century envisioned the use of in vitro toxicity tests using cells of human origin to predict the ability of chemicals to cause toxicity in vivo. Successful implementation of this strategy will ultimately result in fast...

  1. Evaluation of gingival blood as a minimally invasive screening tool for diabetes mellitus among 40-59-year-old adults in dental clinics: A cross-sectional study.

    PubMed

    Partheeban, Indumathi K; Chaly, Preetha; Priyadarshni, Indra; Junaid, Mohammed; Nijesh, J E; Vaishnavi, S

    2017-01-01

    To evaluate a quick, safe, and minimally invasive method to screen for diabetes using gingival blood with the help of self-monitoring glucometer during periodontal examination. A hospital-based, cross-sectional comparative study was conducted among 40-59-year-old diabetic and nondiabetic population who had come for their master health examination to a private tertiary care hospital (Global Hospital and Health City) in Chennai. Among them, those who fulfilled the inclusion criteria were selected for the study. Thirty diabetic and thirty nondiabetic patients with moderate to severe gingivitis were enrolled and subjected to routine clinical periodontal examination. Blood samples of two sites were analyzed using a glucose self-monitoring device (Accu-Check). Patients were tested for venous fasting blood sugar (VFBS), venous postprandial blood sugar (VPPS), gingival fasting blood sugar (GFBS) level, gingival postprandial blood sugar (GPPS) level, peripheral fingerstick fasting blood sugar (PFBS) level, and peripheral fingerstick postprandial sugar (PPPS) level. Data obtained were statistically analyzed using Student's t-test, ANOVA, and Pearson's correlation test. A significant positive correlation was found between GFBS and VFBS, GFBS and PFBS, GPPS and VPPS, and GPPS and PPPS (P < 0.01) in both diabetic and nondiabetic patients correlation. Using venous blood glucose level as a gold standard, the sensitivity and specificity of GFBS was 93% and 100%, respectively, whereas in GPPS, the sensitivity and specificity was 80% and 96%, respectively. Gingival blood glucometry can be used as a minimally invasive screening tool for diabetes mellitus in dental clinics.

  2. Screening for diabetes and prediabetes should be cost-saving in patients at high risk.

    PubMed

    Chatterjee, Ranee; Narayan, K M Venkat; Lipscomb, Joseph; Jackson, Sandra L; Long, Qi; Zhu, Ming; Phillips, Lawrence S

    2013-07-01

    Although screening for diabetes and prediabetes is recommended, it is not clear how best or whom to screen. We therefore compared the economics of screening according to baseline risk. Five screening tests were performed in 1,573 adults without known diabetes--random plasma/capillary glucose, plasma/capillary glucose 1 h after 50-g oral glucose (any time, without previous fast, plasma glucose 1 h after a 50-g oral glucose challenge [GCTpl]/capillary glucose 1 h after a 50-g oral glucose challenge [GCTcap]), and A1C--and a definitive 75-g oral glucose tolerance test. Costs of screening included the following: costs of testing (screen plus oral glucose tolerance test, if screen is positive); costs for false-negative results; and costs of treatment of true-positive results with metformin, all over the course of 3 years. We compared costs for no screening, screening everyone for diabetes or high-risk prediabetes, and screening those with risk factors based on age, BMI, blood pressure, waist circumference, lipids, or family history of diabetes. Compared with no screening, cost-savings would be obtained largely from screening those at higher risk, including those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, with differences of up to -46% of health system costs for screening for diabetes and -21% for screening for dysglycemia110, respectively (all P < 0.01). GCTpl would be the least expensive screening test for most high-risk groups for this population over the course of 3 years. From a health economics perspective, screening for diabetes and high-risk prediabetes should target patients at higher risk, particularly those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, for whom screening can be most cost-saving. GCTpl is generally the least expensive test in high-risk groups and should be considered for routine use as an opportunistic screen in these groups.

  3. Effects of telephone follow-up on blood glucose levels and postpartum screening in mothers with Gestational Diabetes Mellitus.

    PubMed

    Khorshidi Roozbahani, Rezvan; Geranmayeh, Mehrnaz; Hantoushzadeh, Sedigheh; Mehran, Abbas

    2015-01-01

    Gestational diabetes mellitus (GDM) is a form of diabetes that occurs in pregnancy. GDM, defined as glucose intolerance, first diagnosed or initiated during pregnancy affects 1-14% of pregnancies based on various studies. Screening and early diagnosis and appropriate glycemic control can improve prenatal outcomes. Telephone follow-up seems to be a reasonable way for pregnant women follow-up. The present study evaluated the effects of telephone follow-up on blood glucose level during pregnancy and postpartum screening. Eighty mothers with GDM were enrolled in this clinical trial and randomly divided into intervention and control groups. All mothers were asked to check their blood sugar levels fivetimes daily. In intervention group, telephone intervention was performed for 10 weeks. In each follow-up, individuals were followed for insulin injections, diet, clinical tests and reminding the next visit. In control group, three times of telephone call was established to record blood sugar levels. Another telephone call was established at 6 weeks of postpartum in both study groups to evaluate the performance of the screening test for blood sugar. The mean age of mothers was 30.9±5 years in the control and 30.7±5.1 years in the intervention groups In intervention group, mean level of blood glucose, 2 hours after lunch at 28 weeks of pregnancy was significantly lower than the control group (P<0.05). Mean differences in levels of fasting blood glucose between 28 weeks and 32 and between 28 and 36 weeks of pregnancy were significantly higher in the intervention than the control group (P<0.05). Rate of postpartum glucose screening test was significantly higher in the intervention group (P<0.001). The findings of this study demonstrated that telephone follow-up could significantly reduce fasting blood glucose levels in mothers with gestational diabetes and also increased the rate of postpartum screening test.

  4. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Development of a screening tool using electronic health records for undiagnosed Type 2 diabetes mellitus and impaired fasting glucose detection in the Slovenian population.

    PubMed

    Štiglic, G; Kocbek, P; Cilar, L; Fijačko, N; Stožer, A; Zaletel, J; Sheikh, A; Povalej Bržan, P

    2018-05-01

    To develop and validate a simplified screening test for undiagnosed Type 2 diabetes mellitus and impaired fasting glucose for the Slovenian population (SloRisk) to be used in the general population. Data on 11 391 people were collected from the electronic health records of comprehensive medical examinations in five Slovenian healthcare centres. Fasting plasma glucose as well as information related to the Finnish Diabetes Risk Score questionnaire, FINDRISC, were collected for 2073 people to build predictive models. Bootstrapping-based evaluation was used to estimate the area under the receiver-operating characteristic curve performance metric of two proposed logistic regression models as well as the Finnish Diabetes Risk Score model both at recommended and at alternative cut-off values. The final model contained five questions for undiagnosed Type 2 diabetes prediction and achieved an area under the receiver-operating characteristic curve of 0.851 (95% CI 0.850-0.853). The impaired fasting glucose prediction model included six questions and achieved an area under the receiver-operating characteristic curve of 0.840 (95% CI 0.839-0.840). There were four questions that were included in both models (age, sex, waist circumference and blood sugar history), with physical activity selected only for undiagnosed Type 2 diabetes and questions on family history and hypertension drug use selected only for the impaired fasting glucose prediction model. This study proposes two simplified models based on FINDRISC questions for screening of undiagnosed Type 2 diabetes and impaired fasting glucose in the Slovenian population. A significant improvement in performance was achieved compared with the original FINDRISC questionnaire. Both models include waist circumference instead of BMI. © 2018 Diabetes UK.

  6. Fasting triglycerides as a predictor of incident diabetes, insulin resistance and β-cell function in a Canadian First Nation.

    PubMed

    Riediger, Natalie D; Clark, Kirsten; Lukianchuk, Virginia; Roulette, Joanne; Bruce, Sharon

    2017-01-01

    Diabetes prevalence is substantially higher among Canadian First Nations populations than the non-First Nation population. Fasting serum triglycerides have been found to be an important predictor of incident diabetes among non-indigenous populations. However, there is a great need to understand diabetes progression within specific ethnic groups, particularly First Nations populations. The purpose of this study was to test for an association between fasting serum triglycerides and incident diabetes, changes in insulin resistance and changes in β-cell function in a Manitoba First Nation cohort. Study data were from two diabetes screening studies in Sandy Bay First Nation in Manitoba, Canada, collected in 2002/2003 and 2011/2012. The cohort was composed of respondents to both screening studies (n=171). Fasting blood samples and anthropometric, health and demographic data were collected. A generalised linear model with Poisson distribution was used to test for an association between fasting triglycerides and incident diabetes. There were 35 incident cases of diabetes among 128 persons without diabetes at baseline. Participants who developed incident type 2 diabetes were significantly older and had significantly higher body mass index (BMI; p=0.012), total cholesterol (p=0.007), fasting triglycerides (p<0.001), and Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) (p<0.001). Fasting triglyceride level was found to be a statistically significant positive predictor of incident diabetes independent of age, sex and waist circumference at baseline. Participants with triglycerides in the highest tertile (≥2.11 mmol/l) had a 4.0-times higher risk of developing incident diabetes compared to those in the lowest tertile (p=0.03). Notably, neither waist circumference nor BMI were significant predictors of incident diabetes independent of age, sex and triglycerides. Fasting triglycerides may be useful as a clinical predictor of insulin resistance and diabetes development among First Nations populations. Unlike other ethnic groups, BMI and waist circumference may be less important factors in diabetes development.

  7. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  8. Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

    NASA Technical Reports Server (NTRS)

    Aldridge, Edward; Curry, Bruce; Scully, Robert

    2015-01-01

    Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

  9. 50 Grams Oral Glucose Challenge Test: Is It an Effective Screening Test for Gestational Diabetes Mellitus?

    PubMed

    Abu-Heija, Adel; Al-Bash, Majeda; Ishrat, Noreen; Al-Kharausi, Lamya

    2016-10-01

    To find out whether 50 g oral glucose challenge test (OGCT) is an effective screening test for all pregnant women between 24 and 28 weeks gestation. A 50 g OGCT test was administered to 307 unselected women at 24-28 weeks of gestation. When venous plasma glucose (VPG) concentration after 1 h was >7.8 mmol/l, OGCT was positive. Women with a positive OGCT underwent 2 h 75 grams oral glucose tolerance test (OGTT) as a confirmatory diagnosis of GDM. When fasting and 2 h post 75 g OGTT values were >5.5 mmol/I and >8 mmol/l, respectively, women were considered diabetic. We screened 307 women for GDM by OGCT. Total number of women with positive OGCT was 83 (27.03 %). In the low-risk group, total number of women with GDM was 9/168 (5.35 %) while the total number of women with GDM in the high-risk group was 14/139 (10.07 %). There was no significant difference with respect to the total number of women with GDM in the groups. A 50 g OGCT seems to be an effective screening test for both groups. More cases of GDM can be discovered when universal rather than risk-related screening is applied.

  10. Relating memory to functional performance in normal aging to dementia using hierarchical Bayesian cognitive processing models.

    PubMed

    Shankle, William R; Pooley, James P; Steyvers, Mark; Hara, Junko; Mangrola, Tushar; Reisberg, Barry; Lee, Michael D

    2013-01-01

    Determining how cognition affects functional abilities is important in Alzheimer disease and related disorders. A total of 280 patients (normal or Alzheimer disease and related disorders) received a total of 1514 assessments using the functional assessment staging test (FAST) procedure and the MCI Screen. A hierarchical Bayesian cognitive processing model was created by embedding a signal detection theory model of the MCI Screen-delayed recognition memory task into a hierarchical Bayesian framework. The signal detection theory model used latent parameters of discriminability (memory process) and response bias (executive function) to predict, simultaneously, recognition memory performance for each patient and each FAST severity group. The observed recognition memory data did not distinguish the 6 FAST severity stages, but the latent parameters completely separated them. The latent parameters were also used successfully to transform the ordinal FAST measure into a continuous measure reflecting the underlying continuum of functional severity. Hierarchical Bayesian cognitive processing models applied to recognition memory data from clinical practice settings accurately translated a latent measure of cognition into a continuous measure of functional severity for both individuals and FAST groups. Such a translation links 2 levels of brain information processing and may enable more accurate correlations with other levels, such as those characterized by biomarkers.

  11. Screening Douglas-fir for rapid early growth in common-garden tests in Spain

    Treesearch

    Gabriel Toval Hernandez; Guillermo Vega Alonso; Gonzalo Puerto Arribas; James L. Jenkinson

    1993-01-01

    Douglas-firs from 91 seed sources in North America were evaluated after 5 and 6 years in 15 common-garden tests in the mountainous regions of northwest and north central Spain. Analyses of tallest trees showed that most of the sources of highest potential for reforestation in Spain are found in regions where the Pacific Ocean air mass dominates climate. Fast growers...

  12. Efficacy and effectiveness of screen and treat policies in prevention of type 2 diabetes: systematic review and meta-analysis of screening tests and interventions.

    PubMed

    Barry, Eleanor; Roberts, Samantha; Oke, Jason; Vijayaraghavan, Shanti; Normansell, Rebecca; Greenhalgh, Trisha

    2017-01-04

     To assess diagnostic accuracy of screening tests for pre-diabetes and efficacy of interventions (lifestyle or metformin) in preventing onset of type 2 diabetes in people with pre-diabetes.  Systematic review and meta-analysis.  Medline, PreMedline, and Embase. Study protocols and seminal papers were citation-tracked in Google Scholar to identify definitive trials and additional publications. Data on study design, methods, and findings were extracted onto Excel spreadsheets; a 20% sample was checked by a second researcher. Data extracted for screening tests included diagnostic accuracy and population prevalence. Two meta-analyses were performed, one summarising accuracy of screening tests (with the oral glucose tolerance test as the standard) for identification of pre-diabetes, and the other assessing relative risk of progression to type 2 diabetes after either lifestyle intervention or treatment with metformin.  Empirical studies evaluating accuracy of tests for identification of pre-diabetes. Interventions (randomised trials and interventional studies) with a control group in people identified through screening. No language restrictions.  2874 titles were scanned and 148 papers (covering 138 studies) reviewed in full. The final analysis included 49 studies of screening tests (five of which were prevalence studies) and 50 intervention trials. HbA 1c had a mean sensitivity of 0.49 (95% confidence interval 0.40 to 0.58) and specificity of 0.79 (0.73 to 0.84), for identification of pre-diabetes, though different studies used different cut-off values. Fasting plasma glucose had a mean sensitivity of 0.25 (0.19 to 0.32) and specificity of 0.94 (0.92 to 0.96). Different measures of glycaemic abnormality identified different subpopulations (for example, 47% : of people with abnormal HbA 1c had no other glycaemic abnormality). Lifestyle interventions were associated with a 36% (28% to 43%) reduction in relative risk of type 2 diabetes over six months to six years, attenuating to 20% (8% to 31%) at follow-up in the period after the trails.  HbA 1c is neither sensitive nor specific for detecting pre-diabetes; fasting glucose is specific but not sensitive. Interventions in people classified through screening as having pre-diabetes have some efficacy in preventing or delaying onset of type 2 diabetes in trial populations. As screening is inaccurate, many people will receives an incorrect diagnosis and be referred on for interventions while others will be falsely reassured and not offered the intervention. These findings suggest that "screen and treat" policies alone are unlikely to have substantial impact on the worsening epidemic of type 2 diabetes.  PROSPERO (No CRD42016042920). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Early Pregnancy Biochemical Predictors of Gestational Diabetes Mellitus.

    PubMed

    Powe, Camille E

    2017-02-01

    Universal oral glucose tolerance-based screening is employed to identify pregnant women with gestational diabetes mellitus (GDM), as treatment of this condition decreases the risk of associated complications. A simple and accurate blood test which identifies women at low or high risk for GDM in the first trimester would have the potential to decrease costs and improve outcomes through prevention or treatment. This review summarizes published data on early pregnancy biomarkers which have been tested as predictors of GDM. A large number of first-trimester biochemical predictors of GDM have been reported, mostly in small case-control studies. These include glycemic markers (fasting glucose, post-load glucose, hemoglobin A1C), inflammatory markers (C-reactive protein, tumor necrosis factor-alpha), insulin resistance markers (fasting insulin, sex hormone-binding globulin), adipocyte-derived markers (adiponectin, leptin), placenta-derived markers (follistatin-like-3, placental growth factor, placental exosomes), and others (e.g., glycosylated fibronectin, soluble (pro)renin receptor, alanine aminotransferase, ferritin). A few large studies suggest that first-trimester fasting glucose or hemoglobin A1C may be useful for identifying women who would benefit from early GDM treatment. To translate the findings from observational studies of first-trimester biomarkers for GDM to clinical practice, trials or cost-effectiveness analyses of screening and treatment strategies based on these novel biomarkers are needed.

  14. The efficacy and cost of alternative strategies for systematic screening for type 2 diabetes in the U.S. population 45-74 years of age.

    PubMed

    Johnson, Susan L; Tabaei, Bahman P; Herman, William H

    2005-02-01

    To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.

  15. Burning mouth syndrome: results of screening tests for vitamin and mineral deficiencies, thyroid hormone, and glucose levels-experience at Mayo Clinic over a decade.

    PubMed

    Morr Verenzuela, Claudia S; Davis, Mark D P; Bruce, Alison J; Torgerson, Rochelle R

    2017-09-01

    Burning mouth syndrome (BMS) is a disorder characterized by chronic mouth pain in the absence of objective clinical abnormalities. Vitamin or mineral deficiencies may have a role in BMS, but data regarding the prevalence and relevance of hematinic deficiencies are conflicting. We aimed to determine the frequency of specific laboratory abnormalities in patients with BMS. We retrospectively reviewed the results of screening blood tests in patients with BMS at our institution between January 2003 and December 2013. Among 659 patients with BMS, the most common decreased values or deficiencies were vitamin D 3 (15%), vitamin B 2 (15%), vitamin B 6 (5.7%), zinc (5.7%), vitamin B 1 (5.3%), thyrotropin (TSH) (3.2%), vitamin B 12 (0.8%), and folic acid (0.7%). Laboratory values for fasting blood glucose and TSH were increased in 23.7% and 5.2%, respectively. In patients with symptoms of BMS, our results suggest it is reasonable to screen for fasting blood glucose, vitamin D (D 2 and D 3 ), vitamin B 6 , zinc, vitamin B 1 , and TSH. Deficiencies of vitamin B 12 and folic acid were rare (<1% abnormal). © 2017 The International Society of Dermatology.

  16. Fasting plasma glucose as initial screening for diabetes and prediabetes in irish adults: The Diabetes Mellitus and Vascular health initiative (DMVhi).

    PubMed

    Sinnott, Margaret; Kinsley, Brendan T; Jackson, Abaigeal D; Walsh, Cathal; O'Grady, Tony; Nolan, John J; Gaffney, Peter; Boran, Gerard; Kelleher, Cecily; Carr, Bernadette

    2015-01-01

    Type 2 diabetes has a long pre clinical asymptomatic phase. Early detection may delay or arrest disease progression. The Diabetes Mellitus and Vascular health initiative (DMVhi) was initiated as a prospective longitudinal cohort study on the prevalence of undiagnosed Type 2 diabetes and prediabetes, diabetes risk and cardiovascular risk in a cohort of Irish adults aged 45-75 years. Members of the largest Irish private health insurance provider aged 45 to 75 years were invited to participate in the study. already diagnosed with diabetes or taking oral hypoglycaemic agents. Participants completed a detailed medical questionnaire, had weight, height, waist and hip circumference and blood pressure measured. Fasting blood samples were taken for fasting plasma glucose (FPG). Those with FPG in the impaired fasting glucose (IFG) range had a 75gm oral glucose tolerance test performed. 122,531 subjects were invited to participate. 29,144 (24%) completed the study. The prevalence of undiagnosed diabetes was 1.8%, of impaired fasting glucose (IFG) was 7.1% and of impaired glucose tolerance (IGT) was 2.9%. Dysglycaemia increased among those aged 45-54, 55-64 and 65-75 years in both males (10.6%, 18.5%, 21.7% respectively) and females (4.3%, 8.6%, 10.9% respectively). Undiagnosed T2D, IFG and IGT were all associated with gender, age, blood pressure, BMI, abdominal obesity, family history of diabetes and triglyceride levels. Using FPG as initial screening may underestimate the prevalence of T2D in the study population. This study is the largest screening study for diabetes and prediabetes in the Irish population. Follow up of this cohort will provide data on progression to diabetes and on cardiovascular outcomes.

  17. Fast Optimization of LiMgMnOx/La2O3 Catalysts for the Oxidative Coupling of Methane.

    PubMed

    Li, Zhinian; He, Lei; Wang, Shenliang; Yi, Wuzhong; Zou, Shihui; Xiao, Liping; Fan, Jie

    2017-01-09

    The development of efficient catalyst for oxidative coupling of methane (OCM) reaction represents a grand challenge in direct conversion of methane into other useful products. Here, we reported that a newly developed combinatorial approach can be used for ultrafast optimization of La 2 O 3 -based multicomponent metal oxide catalysts in OCM reaction. This new approach integrated inkjet printing assisted synthesis (IJP-A) with multidimensional group testing strategy (m-GT) tactfully takes the place of conventionally high-throughput synthesis-and-screen experiment. Just within a week, 2048 formulated LiMgMnO x -La 2 O 3 catalysts in a 64·8·8·8·8 = 262 144 compositional space were fabricated by IJP-A in a four-round synthesis-and-screen process, and an optimized formulation has been successfully identified through only 4·8 = 32 times of tests via m-GT screening strategy. The screening process identifies the most promising ternary composition region is Li 0-0.48 Mg 0-6.54 Mn 0-0.62 -La 100 O x with an external C 2 yield of 10.87% at 700 °C. The yield of C 2 is two times as high as the pure nano-La 2 O 3 . The good performance of the optimized catalyst formulation has been validated by the manual preparation, which further prove the effectiveness of the new combinatorial methodology in fast discovery of heterogeneous catalyst.

  18. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.

    PubMed

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia.

  19. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia

    PubMed Central

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia. PMID:28800632

  20. The Relationship Between Maternal Glycemia and Perinatal Outcome

    PubMed Central

    Landon, Mark B.; Mele, Lisa; Spong, Catherine Y.; Carpenter, Marshall W.; Ramin, Susan M.; Casey, Brian; Wapner, Ronald J.; Varner, Michael W.; Rouse, Dwight J.; Thorp, John M.; Sciscione, Anthony; Catalano, Patrick; Harper, Margaret; Saade, George; Caritis, Steve N; Sorokin, Yoram; Peaceman, Alan M.; Tolosa, Jorge E.; Anderson, Garland D.

    2014-01-01

    Objective To examine the relationship between varying degrees of maternal hyperglycemia and pregnancy outcomes. Methods This was a secondary analysis of a treatment trial for mild gestational diabetes (GDM) including four cohorts: 1) 473 women with untreated mild GDM; 2) 256 women with a positive 50-gram screen and one abnormal oral glucose tolerance test (OGTT) value; 3) 675 women with a positive screen and no abnormal OGTT values; and 4) 437 women with a normal 50-gram screen. Groups were compared by test of trend for a composite perinatal outcome (neonatal hypoglycemia, hyperbilirubinemia, elevated cord c-peptide level, and perinatal trauma or death), frequency of large-for-gestational-age (LGA) infant, shoulder dystocia, and pregnancy-related hypertension. Three-hour OGTT levels (fasting, 1, 2, and 3 hour) levels were divided into categories and analyzed for their relationship to perinatal and maternal outcomes. Results There were significant trends by glycemic status among the four cohorts for the composite and all other outcomes (p<0.001). Analysis for trend according to OGTT categories showed an increasing relationship between fasting and all post load levels and the various outcomes (p<0.05). Fasting glucose ≥ 90 mg/dl and 1 hour ≥ 165 mg/dl were associated with an increased risk for the composite outcome, odds ratios and 95% CI of 2.0 (1.03-4.15) and 1.46 (1.02-2.11) to 1.52 (1.08-2.15), for the fasting and 1 hour, respectively. A 1 hour glucose ≥ 150 mg/dl was associated with an increased risk for LGA (odds ratios 1.8 (1.02-3.18) to 2.35 (1.35-4.14), however 2 and 3 hour glucose levels did not increase the risk for the composite or LGA until well beyond current GDM diagnostic thresholds. Conclusion A monotonic relationship exists between increasing maternal glycemia and perinatal morbidity. Current OGTT criteria require re-evaluation in determining thresholds for the diagnosis and treatment of GDM. PMID:21309194

  1. Paper analytical devices for fast field screening of beta lactam antibiotics and antituberculosis pharmaceuticals.

    PubMed

    Weaver, Abigail A; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya

    2013-07-02

    Reports of low-quality pharmaceuticals have been on the rise in the past decade, with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide and also screen for substitute pharmaceuticals, such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers such as chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain 12 lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a "color bar code" which can be analyzed visually by comparison with standard outcomes. Although quantification of the APIs is poor compared with conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API as well as formulations containing APIs that have been "cut" with inactive ingredients.

  2. Paper analytical devices for fast field screening of beta lactam antibiotics and anti-tuberculosis pharmaceuticals

    PubMed Central

    Weaver, Abigail A.; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya

    2013-01-01

    Reports of low quality pharmaceuticals have been on the rise in the last decade with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide, and also screen for substitute pharmaceuticals such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers like chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain twelve lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a “color bar code” which can be analyzed visually by comparison to standard outcomes. While quantification of the APIs is poor compared to conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API, as well as formulations containing APIs that have been “cut” with inactive ingredients. PMID:23725012

  3. Chemical structure-based predictive model for methanogenic anaerobic biodegradation potential.

    PubMed

    Meylan, William; Boethling, Robert; Aronson, Dallas; Howard, Philip; Tunkel, Jay

    2007-09-01

    Many screening-level models exist for predicting aerobic biodegradation potential from chemical structure, but anaerobic biodegradation generally has been ignored by modelers. We used a fragment contribution approach to develop a model for predicting biodegradation potential under methanogenic anaerobic conditions. The new model has 37 fragments (substructures) and classifies a substance as either fast or slow, relative to the potential to be biodegraded in the "serum bottle" anaerobic biodegradation screening test (Organization for Economic Cooperation and Development Guideline 311). The model correctly classified 90, 77, and 91% of the chemicals in the training set (n = 169) and two independent validation sets (n = 35 and 23), respectively. Accuracy of predictions of fast and slow degradation was equal for training-set chemicals, but fast-degradation predictions were less accurate than slow-degradation predictions for the validation sets. Analysis of the signs of the fragment coefficients for this and the other (aerobic) Biowin models suggests that in the context of simple group contribution models, the majority of positive and negative structural influences on ultimate degradation are the same for aerobic and methanogenic anaerobic biodegradation.

  4. Health fair screening: the clinical utility of the comprehensive metabolic profile.

    PubMed

    Alpert, Jeffrey P; Greiner, Allen; Hall, Sandra

    2004-01-01

    Health fairs are a common method used by providers and health care organizations to provide screening tests, including comprehensive metabolic profiles (CMPs), to asymptomatic individuals. No national organizations currently recommend the complete CMP as a screening test for asymptomatic individuals in primary care settings. This study evaluated the value of CMPs in a health fair setting by measuring the ability of a health fair CMP to predict new medical diagnoses among residents of a sparsely populated rural county. Volunteer participants submitted fasting blood samples at a health fair conducted by a county health center in a county with 2,531 total residents. CMP values were determined to be "normal" or "abnormal" based on laboratory reference ranges and clinical judgment of the health center physicians. Medical records were reviewed 4 months later to determine if participants with abnormal CMP values had been diagnosed with new medical conditions as a result of the screening tests. Analysis was conducted to evaluate CMP test characteristics and determine whether demographic factors or specific CMP values predicted new medical diagnoses in the participants. Out of 478 health fair participants, 73 individuals had at least one abnormal CMP value. The most frequently occurring abnormal value was an elevated glucose level, with Hispanic participants significantly more likely to have this abnormality than whites. After all evaluation was completed, only about 1% of tested subjects had a new diagnosis as a result of the screening CMP test; most abnormal CMP tests did not result in a new diagnosis. The positive predictive value for an abnormal test resulting in a new medical diagnosis was 0.356. Comprehensive metabolic profiles have limited value as a screening tool in asymptomatic populations at health fairs.

  5. Screening for gestational diabetes mellitus in Germany: A qualitative study on pregnant women's attitudes, experiences, and suggestions.

    PubMed

    Görig, Tatiana; Schneider, Sven; Bock, Christina; Maul, Holger; Kleinwechter, Helmut; Diehl, Katharina

    2015-11-01

    to explore pregnant women's experiences with the recently implemented screening for gestational diabetes mellitus (GDM). qualitative study. Rhine-Neckar Metropolitan region, Germany. 20 pregnant women aged 27-41 years (mean: 32.6 years) who were at least in gestational week 29, i.e., those who should have already been screened for GDM. semi-structured interviews with open-ended questions were conducted via telephone between November 2013 and February 2014. All interviews were audiotaped, transcribed verbatim and subsequently analyzed using qualitative content analysis according to Mayring. The screening was seen as an important instrument to detect GDM and thus to prevent possible health problems in both mother and child. Some deviations from the recommended screening procedure were reported in the interviews, e.g., collecting capillary blood instead of venous blood during an oral glucose tolerance test (OGTT); offering an OGTT without a prior glucose challenge test (GCT); conducting a GCT after an overnight fast. Two women had to actively ask for the screening to be done. One woman reported that her gynaecologist advised her against the screening. this qualitative study reflects the women's experiences with the new screening for GDM. Our findings show that two years after the introduction of universal GDM screening in Germany the screening procedure does not always seem to meet the standards of the German maternity guidelines. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Fasting triglycerides as a predictor of incident diabetes, insulin resistance and β-cell function in a Canadian First Nation

    PubMed Central

    Riediger, Natalie D.; Clark, Kirsten; Lukianchuk, Virginia; Roulette, Joanne; Bruce, Sharon

    2017-01-01

    ABSTRACT Background: Diabetes prevalence is substantially higher among Canadian First Nations populations than the non-First Nation population. Fasting serum triglycerides have been found to be an important predictor of incident diabetes among non-indigenous populations. However, there is a great need to understand diabetes progression within specific ethnic groups, particularly First Nations populations. Objective: The purpose of this study was to test for an association between fasting serum triglycerides and incident diabetes, changes in insulin resistance and changes in β-cell function in a Manitoba First Nation cohort. Methods: Study data were from two diabetes screening studies in Sandy Bay First Nation in Manitoba, Canada, collected in 2002/2003 and 2011/2012. The cohort was composed of respondents to both screening studies (n=171). Fasting blood samples and anthropometric, health and demographic data were collected. A generalised linear model with Poisson distribution was used to test for an association between fasting triglycerides and incident diabetes. Results: There were 35 incident cases of diabetes among 128 persons without diabetes at baseline. Participants who developed incident type 2 diabetes were significantly older and had significantly higher body mass index (BMI; p=0.012), total cholesterol (p=0.007), fasting triglycerides (p<0.001), and Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) (p<0.001). Fasting triglyceride level was found to be a statistically significant positive predictor of incident diabetes independent of age, sex and waist circumference at baseline. Participants with triglycerides in the highest tertile (≥2.11 mmol/l) had a 4.0-times higher risk of developing incident diabetes compared to those in the lowest tertile (p=0.03). Notably, neither waist circumference nor BMI were significant predictors of incident diabetes independent of age, sex and triglycerides. Conclusion: Fasting triglycerides may be useful as a clinical predictor of insulin resistance and diabetes development among First Nations populations. Unlike other ethnic groups, BMI and waist circumference may be less important factors in diabetes development. PMID:28406758

  7. Performance of the French version of the 4AT for screening the elderly for delirium in the emergency department.

    PubMed

    Gagné, Anne-Julie; Voyer, Philippe; Boucher, Valérie; Nadeau, Alexandra; Carmichael, Pierre-Hugues; Pelletier, Mathieu; Gouin, Emilie; Berthelot, Simon; Daoust, Raoul; Wilchesky, Machelle; Richard, Hélène; Pelletier, Isabelle; Ballard, Stephanie; Laguë, Antoine; Émond, Marcel

    2018-05-17

    CLINICIAN'S CAPSULE What is known about the topic? Delirium is frequent in older inpatients but often goes undetected. A short tool, the 4 A's Test (4AT), was created and validated for the detection of delirium. What did this study ask? This study compared the performance of the French version of the 4AT (4AT-F) with the Confusion Assessment Method (CAM) for the screening of delirium. What did this study find? The 4AT-F was a fast and reliable screening tool for delirium in the emergency department (ED). Why does this study matter to clinicians? Because of its quick administration time, it allows for systematic screening of patients at risk of delirium and cognitive impairment.

  8. COLA with scale-dependent growth: applications to screened modified gravity models

    NASA Astrophysics Data System (ADS)

    Winther, Hans A.; Koyama, Kazuya; Manera, Marc; Wright, Bill S.; Zhao, Gong-Bo

    2017-08-01

    We present a general parallelized and easy-to-use code to perform numerical simulations of structure formation using the COLA (COmoving Lagrangian Acceleration) method for cosmological models that exhibit scale-dependent growth at the level of first and second order Lagrangian perturbation theory. For modified gravity theories we also include screening using a fast approximate method that covers all the main examples of screening mechanisms in the literature. We test the code by comparing it to full simulations of two popular modified gravity models, namely f(R) gravity and nDGP, and find good agreement in the modified gravity boost-factors relative to ΛCDM even when using a fairly small number of COLA time steps.

  9. Laser mass spectrometry for DNA sequencing, disease diagnosis, and fingerprinting

    NASA Astrophysics Data System (ADS)

    Chen, C. H. Winston; Taranenko, N. I.; Zhu, Y. F.; Chung, C. N.; Allman, S. L.

    1997-05-01

    Since laser mass spectrometry has the potential for achieving very fast DNA analysis, we recently applied it to DNA sequencing, DNA typing for fingerprinting, and DNA screening for disease diagnosis. Two different approaches for sequencing DNA have been successfully demonstrated. One is to sequence DNA with DNA ladders produced from Sanger's enzymatic method. The other is to do direct sequencing without DNA ladders. The need for quick DNA typing for identification purposes is critical for forensic application. Our preliminary results indicate laser mass spectrometry can possible be used for rapid DNA fingerprinting applications at a much lower cost than gel electrophoresis. Population screening for certain genetic disease can be a very efficient step to reducing medical costs through prevention. Since laser mass spectrometry can provide very fast DNA analysis, we applied laser mass spectrometry to disease diagnosis. Clinical samples with both base deletion and point mutation have been tested with complete success.

  10. Diagnostic Accuracies of Glycated Hemoglobin, Fructosamine, and Homeostasis Model Assessment of Insulin Resistance in Predicting Impaired Fasting Glucose, Impaired Glucose Tolerance, or New Onset Diabetes After Transplantation.

    PubMed

    Rosettenstein, Kerri; Viecelli, Andrea; Yong, Kenneth; Nguyen, Hung Do; Chakera, Aron; Chan, Doris; Dogra, Gursharan; Lim, Ee Mun; Wong, Germaine; Lim, Wai H

    2016-07-01

    New onset diabetes after transplantation (NODAT) is associated with a 3-fold greater risk of cardiovascular disease events, with early identification and treatment potentially attenuating this risk. The optimal screening test to identify those with NODAT remains unclear, and the aim of this study was to examine the diagnostic accuracies of 4 screening tests in identifying impaired fasting glucose, impaired glucose tolerance (IGT), and NODAT. This is a single-center prospective cohort study of 83 nondiabetic kidney transplant recipients between 2008 and 2011. Oral glucose tolerance test was considered the gold standard in identifying IFG/IGT or NODAT. Diagnostic accuracies of random blood glucose, glycated hemoglobin (HBA1c), fructosamine, and Homeostasis Model Assessment-Insulin Resistance in predicting IFG/IGT or NODAT were assessed using the area under the receiver operating characteristic curve. Forty (48%) recipients had IFG/IGT or NODAT. Compared with HBA1c with adjusted area under the curve (AUC) of 0.88 (95% confidence interval [95% CI], 0.77-0.93), fructosamine was the most accurate test with adjusted AUC of 0.92 (95% CI, 0.83-0.96). The adjusted AUCs of random blood glucose and Homeostasis Model Assessment-Insulin Resistance in identifying IFG/IGT were between 0.81 and 0.85. Restricting to identifying IGT/NODAT using 2-hour oral glucose tolerance test (n = 66), fructosamine was the most accurate diagnostic test with adjusted AUC of 0.93 (95% CI, 0.84-0.99), but not statistically different to HBA1c with adjusted AUC of 0.88 (95% CI, 0.76-0.96). Although HBA1c is an acceptable and widely used screening test in detecting IFG/IGT or NODAT, fructosamine may be a more accurate diagnostic test but this needs to be further examined in larger cohorts.

  11. Positive FAST without hemoperitoneum due to fluid resuscitation in blunt trauma.

    PubMed

    Slutzman, Jonathan E; Arvold, Lisa A; Rempell, Joshua S; Stone, Michael B; Kimberly, Heidi H

    2014-10-01

    The focused assessment with sonography in trauma (FAST) examination is an important screening tool in the evaluation of blunt trauma patients. To describe a case of a hemodynamically unstable polytrauma patient with positive FAST due to fluid resuscitation after blunt trauma. We describe a case of a hemodynamically unstable polytrauma patient who underwent massive volume resuscitation prior to transfer from a community hospital to a trauma center. On arrival at the receiving institution, the FAST examination was positive for free intraperitoneal fluid, but no hemoperitoneum or significant intra-abdominal injuries were found during laparotomy. In this case, it is postulated that transudative intraperitoneal fluid secondary to massive volume resuscitation resulted in a positive FAST examination. This case highlights potential issues specific to resuscitated trauma patients with prolonged transport times. Further study is likely needed to assess what changes, if any, should be made in algorithms to address the effect of prior resuscitative efforts on the test characteristics of the FAST examination. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Incidental findings of elevated random plasma glucose in the ED as a prompt for outpatient diabetes screening: a retrospective study

    PubMed Central

    Friedman, Steven Marc; Vallipuram, Janaki; Baswick, Brenda

    2013-01-01

    Objective To determine whether random plasma glucose (RPG) collected from patients without known impaired glucose metabolism (IGM) in the emergency department (ED) is a useful screen for diabetes or prediabetes. Design Retrospective cohort study. Setting ED of a Canadian teaching hospital over 1 month. Participants Adult patients in ED with RPG over 7 mmol/L were recruited for participation. Exclusion criteria included known diabetes, hospital admission and inability to consent. Participants were contacted by mail, encouraged to follow-up with their family physician (FP) for further testing and subsequently interviewed. Outcome measures The primary outcome measure was the proportion of patients in the ED with RPG over 7 mmol/L and no previous diagnosis of IGM who were diagnosed with diabetes or prediabetes after secondary testing by FP with oral glucose tolerance test or fasting plasma glucose (FPG). Secondary outcomes included patient characteristics (age, gender, body mass index and language) and (2) compliance with advice to seek an appropriate follow-up care. Results RPG was drawn on approximately one-third (33%, n=1149) of the 3470 patients in the ED in March 2010. RPG over 7 mmol/L was detected in 24% (n=278) of patients, and after first telephone follow-up, 32% (n=88/278) met the inclusion criteria and were advised to seek confirmatory testing. 41% (n=114/278) of patients were excluded for known diabetes. 73% of patients contacted (n=64/88) followed up with their FP. 12.5% (n=11/88) of patients had abnormal FPG, and of these 11% (n=10/88) were encouraged to initiate lifestyle modifications and 1% (n=1/88) was started on an oral hypoglycaemic agent. For 7% (n=6/88) of patients, FP's declined to do follow-up fasting blood work. Conclusions Elevated RPG in the ED is useful for identification of patients at risk for IGM and in need of further diabetic screening. Emergency physicians should advise patients with elevated RPG to consider screening for diabetes. For ED screening to be successful, patient education and collaboration with FPs are essential. PMID:24353254

  13. Incidental findings of elevated random plasma glucose in the ED as a prompt for outpatient diabetes screening: a retrospective study.

    PubMed

    Friedman, Steven Marc; Vallipuram, Janaki; Baswick, Brenda

    2013-12-18

    To determine whether random plasma glucose (RPG) collected from patients without known impaired glucose metabolism (IGM) in the emergency department (ED) is a useful screen for diabetes or prediabetes. Retrospective cohort study. ED of a Canadian teaching hospital over 1 month. Adult patients in ED with RPG over 7 mmol/L were recruited for participation. Exclusion criteria included known diabetes, hospital admission and inability to consent. Participants were contacted by mail, encouraged to follow-up with their family physician (FP) for further testing and subsequently interviewed. The primary outcome measure was the proportion of patients in the ED with RPG over 7 mmol/L and no previous diagnosis of IGM who were diagnosed with diabetes or prediabetes after secondary testing by FP with oral glucose tolerance test or fasting plasma glucose (FPG). Secondary outcomes included patient characteristics (age, gender, body mass index and language) and (2) compliance with advice to seek an appropriate follow-up care. RPG was drawn on approximately one-third (33%, n=1149) of the 3470 patients in the ED in March 2010. RPG over 7 mmol/L was detected in 24% (n=278) of patients, and after first telephone follow-up, 32% (n=88/278) met the inclusion criteria and were advised to seek confirmatory testing. 41% (n=114/278) of patients were excluded for known diabetes. 73% of patients contacted (n=64/88) followed up with their FP. 12.5% (n=11/88) of patients had abnormal FPG, and of these 11% (n=10/88) were encouraged to initiate lifestyle modifications and 1% (n=1/88) was started on an oral hypoglycaemic agent. For 7% (n=6/88) of patients, FP's declined to do follow-up fasting blood work. Elevated RPG in the ED is useful for identification of patients at risk for IGM and in need of further diabetic screening. Emergency physicians should advise patients with elevated RPG to consider screening for diabetes. For ED screening to be successful, patient education and collaboration with FPs are essential.

  14. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  15. What is overdiagnosis and why should we take it seriously in cancer screening?

    PubMed

    Carter, Stacy M; Barratt, Alexandra

    2017-07-26

    Overdiagnosis occurs in a population when conditions are diagnosed correctly but the diagnosis produces an unfavourable balance between benefits and harms. In cancer screening, overdiagnosed cancers are those that did not need to be found because they would not have produced symptoms or led to premature death. These overdiagnosed cancers can be distinguished from false positives, which occur when an initial screening test suggests that a person is at high risk but follow-up testing shows them to be at normal risk. The cancers most likely to be overdiagnosed through screening are those of the prostate, thyroid, breast and lung. Overdiagnosis in cancer screening arises largely from the paradoxical problem that screening is most likely to find the slow-growing or dormant cancers that are least likely to harm us, and less likely to find the aggressive, fast-growing cancers that cause cancer mortality. This central paradox has become clearer over recent decades. The more overdiagnosis is produced by a screening program, the less likely the program is to serve its ultimate goal of reducing illness and premature death from cancer. Thus, it is vital that health professionals and researchers continue an open, scientific inquiry into the extent and consequences of overdiagnosis, and devise appropriate responses to it.

  16. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol

    PubMed Central

    2009-01-01

    Background A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Methods and design Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) or the Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors associated with successful implementation. Discussion The trial will evaluate the impact of screening and brief alcohol intervention in routine probation work and therefore its findings will be highly relevant to probation teams and thus the criminal justice system in the UK. Ethical approval was given by Northern & Yorkshire REC Trial Registration number ISRCTN 19160244 PMID:19922618

  17. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol.

    PubMed

    Newbury-Birch, Dorothy; Bland, Martin; Cassidy, Paul; Coulton, Simon; Deluca, Paolo; Drummond, Colin; Gilvarry, Eilish; Godfrey, Christine; Heather, Nick; Kaner, Eileen; Myles, Judy; Oyefeso, Adenekan; Parrott, Steve; Perryman, Katherine; Phillips, Tom; Shenker, Don; Shepherd, Jonathan

    2009-11-18

    A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) or the Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors associated with successful implementation. The trial will evaluate the impact of screening and brief alcohol intervention in routine probation work and therefore its findings will be highly relevant to probation teams and thus the criminal justice system in the UK.Ethical approval was given by Northern & Yorkshire REC. ISRCTN 19160244.

  18. Screening for hypopituitarism in 509 patients with traumatic brain injury or subarachnoid hemorrhage.

    PubMed

    Kopczak, Anna; Kilimann, Ingo; von Rosen, Friedrich; Krewer, Carmen; Schneider, Harald Jörn; Stalla, Günter Karl; Schneider, Manfred

    2014-01-01

    We performed a screening on patients with traumatic brain injury (TBI) or subarachnoid hemorrhage (SAH) to determine the prevalence of post-traumatic hypopituitarism in neurorehabilitation in a cross-sectional, observational single-center study. In addition, the therapeutic consequences of our screening were analyzed retrospectively. From February 2006 to August 2009, patients between 18 and 65 years (n=509) with the diagnosis of TBI (n=340) or SAH (n=169) were screened within two weeks of admittance to neurorehabilitation as clinical routine. Blood was drawn to determine fasting cortisol, free thyroxine (fT4), prolactin, testosterone or estradiol, and insulin-like growth factor I (IGF-I). Patients with abnormalities in the screening or clinical signs of hypopituitarism received further stimulation tests: growth hormone releasing hormone -L-arginine-test and adrenocorticotrophic hormone (ACTH)-test (n=36); ACTH-test alone (n=26); or insulin tolerance test (n=56). In our screening of 509 patients, 28.5% showed lowered values in at least one hormone of the hypothalamus-pituitary axis and 4.5% in two or more axes. The most common disturbance was a decrease of testosterone in 40.7% of all men (in the following 13/131 men were given substitution therapy). Low fT4 was detected in 5.9% (n=3 were given substitution therapy). Low IGF-I was detected in 5.8%, low cortisol in 1.4%, and low prolactin in 0.2%; none were given substitution therapy. Further stimulation tests revealed growth hormone deficiency in 20.7% (n=19/92) and hypocortisolism in 23.7% (n=28/118). Laboratory values possibly indicating hypopituitarism (33%) were common but did not always implicate post-traumatic hypopituitarism. Laboratory values possibly indicating hypopituitarism were common in our screening but most patients were clinically not diagnosed as pituitary insufficient and did not receive hormone replacement therapy. A routine screening of all patients in neurorehabilitation without considering the time since injury, the severity of illness and therapeutic consequences seems not useful.

  19. Clinical utility of a single-item test for DSM-5 alcohol use disorder among outpatients with anxiety and depressive disorders.

    PubMed

    Bartoli, Francesco; Crocamo, Cristina; Biagi, Enrico; Di Carlo, Francesco; Parma, Francesca; Madeddu, Fabio; Capuzzi, Enrico; Colmegna, Fabrizia; Clerici, Massimo; Carrà, Giuseppe

    2016-08-01

    There is a lack of studies testing accuracy of fast screening methods for alcohol use disorder in mental health settings. We aimed at estimating clinical utility of a standard single-item test for case finding and screening of DSM-5 alcohol use disorder among individuals suffering from anxiety and mood disorders. We recruited adults consecutively referred, in a 12-month period, to an outpatient clinic for anxiety and depressive disorders. We assessed the National Institute on Alcohol Abuse and Alcoholism (NIAAA) single-item test, using the Mini- International Neuropsychiatric Interview (MINI), plus an additional item of Composite International Diagnostic Interview (CIDI) for craving, as reference standard to diagnose a current DSM-5 alcohol use disorder. We estimated sensitivity and specificity of the single-item test, as well as positive and negative Clinical Utility Indexes (CUIs). 242 subjects with anxiety and mood disorders were included. The NIAAA single-item test showed high sensitivity (91.9%) and specificity (91.2%) for DSM-5 alcohol use disorder. The positive CUI was 0.601, whereas the negative one was 0.898, with excellent values also accounting for main individual characteristics (age, gender, diagnosis, psychological distress levels, smoking status). Testing for relevant indexes, we found an excellent clinical utility of the NIAAA single-item test for screening true negative cases. Our findings support a routine use of reliable methods for rapid screening in similar mental health settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Evaluation of dysphagia in early stroke patients by bedside, endoscopic, and electrophysiological methods.

    PubMed

    Umay, Ebru Karaca; Unlu, Ece; Saylam, Guleser Kılıc; Cakci, Aytul; Korkmaz, Hakan

    2013-09-01

    We aimed in this study to evaluate dysphagia in early stroke patients using a bedside screening test and flexible fiberoptic endoscopic evaluation of swallowing (FFEES) and electrophysiological evaluation (EE) methods and to compare the effectiveness of these methods. Twenty-four patients who were hospitalized in our clinic within the first 3 months after stroke were included in this study. Patients were evaluated using a bedside screening test [including bedside dysphagia score (BDS), neurological examination dysphagia score (NEDS), and total dysphagia score (TDS)] and FFEES and EE methods. Patients were divided into normal-swallowing and dysphagia groups according to the results of the evaluation methods. Patients with dysphagia as determined by any of these methods were compared to the patients with normal swallowing based on the results of the other two methods. Based on the results of our study, a high BDS was positively correlated with dysphagia identified by FFEES and EE methods. Moreover, the FFEES and EE methods were positively correlated. There was no significant correlation between NEDS and TDS levels and either EE or FFEES method. Bedside screening tests should be used mainly as an initial screening test; then FFEES and EE methods should be combined in patients who show risks. This diagnostic algorithm may provide a practical and fast solution for selected stroke patients.

  1. Initial impact and cost of a nationwide population screening campaign for diabetes in Brazil: A follow up study

    PubMed Central

    Toscano, Cristiana M; Duncan, Bruce B; Mengue, Sotero S; Polanczyk, Carísi Anne; Nucci, Luciana B; Costa e Forti, Adriana; Fonseca, Cláudio D; Schmidt, Maria Inês

    2008-01-01

    Background In 2001 Brazilian citizens aged 40 or older were invited to participate in a nationwide population screening program for diabetes. Capillary glucose screening tests and procedures for diagnostic confirmation were offered through the national healthcare system, diagnostic priority being given according to the severity of screening results. The objective of this study is to evaluate the initial impact of the program. Methods Positive testing was defined by a fasting capillary glucose ≥ 100 mg/dL or casual glucose ≥ 140 mg/dL. All test results were tabulated locally and aggregate data by gender and clinical categories were sent to the Ministry of Health. To analyze individual characteristics of screening tests performed, a stratified random sample of 90,106 tests was drawn. To describe the actions taken for positive screenees, a random sub-sample of 4,906 positive screenees was actively followed up through home interviews. Main outcome measures considered were the number of diabetes cases diagnosed and cost per case detected and incorporated into healthcare. Results Of 22,069,905 screening tests performed, we estimate that 3,417,106 (95% CI 3.1 – 3.7 million) were positive and that 346,168 (290,454 – 401,852) new cases were diagnosed (10.1% of positives), 319,157 (92.2%) of these being incorporated into healthcare. The number of screening tests needed to detect one case of diabetes was 64. As many cases of untreated but previously known diabetes were also linked to healthcare providers during the Campaign, the estimated number needed screen to incorporate one case into the healthcare system was 58. Total screening and diagnostic costs were US$ 26.19 million, the cost per diabetes case diagnosed being US$ 76. Results were especially sensitive to proportion of individuals returning for diagnostic confirmation. Conclusion This nationwide population-based screening program, conducted through primary healthcare services, demonstrates the feasibility, within the context of an organized national healthcare system, of screening campaigns for chronic diseases. Although overall costs were significant, cost per new case diagnosed was lower than previously reported. However, cost-effectiveness analysis based on more clinically significant outcomes needs to be conducted before this screening approach can be recommended in other settings. PMID:18808662

  2. Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    PubMed

    Goryacheva, I Yu; De Saeger, S; Lobeau, M; Eremin, S A; Barna-Vetró, I; Van Peteghem, C

    2006-09-01

    An approach for ochratoxin A (OTA) fast cost-effective screening based on clean-up tandem immunoassay columns was developed and optimized for OTA detection with a cut-off level of 10 microg kg(-1) in spices. Two procedures were tested and applied for OTA detection. Column with bottom detection immunolayer was optimized for OTA determination in Capsicum ssp. spices. A modified clean-up tandem immunoassay procedure with top detection immunolayer was successfully applied for all tested spices. Its main advantages were decreasing of the number of analysis steps and quantity of antibody and also minimizing of matrix effects. The total duration of the extraction and analysis was about 40 min for six samples. Chilli, red pepper, pili-pili, cayenne, paprika, nutmeg, ginger, white pepper and black pepper samples were analyzed for OTA contamination by the proposed clean-up tandem immunoassay procedures. Clean-up tandem immunoassay results were confirmed by HPLC-MS/MS with immunoaffinity column clean-up. Among 17 tested Capsicum ssp. spices, 6 samples (35%) contained OTA in a concentration exceeding the 10 microg kg(-1) limit discussed by the European Commission. All tested nutmeg (n=8), ginger (n=5), white pepper (n=7) and black pepper (n=6) samples did not contain OTA above this action level.

  3. Establishing an EGFR mutation screening service for non-small cell lung cancer - sample quality criteria and candidate histological predictors.

    PubMed

    Leary, Alexandra F; Castro, David Gonzalez de; Nicholson, Andrew G; Ashley, Sue; Wotherspoon, Andrew; O'Brien, Mary E R; Popat, Sanjay

    2012-01-01

    EGFR screening requires good quality tissue, sensitivity and turn-around time (TAT). We report our experience of routine screening, describing sample type, TAT, specimen quality (cellularity and DNA yield), histopathological description, mutation result and clinical outcome. Non-small cell lung cancer (NSCLC) sections were screened for EGFR mutations (M+) in exons 18-21. Clinical, pathological and screening outcome data were collected for year 1 of testing. Screening outcome alone was collected for year 2. In year 1, 152 samples were tested, most (72%) were diagnostic. TAT was 4.9 days (95%confidence interval (CI)=4.5-5.5). EGFR-M+ prevalence was 11% and higher (20%) among never-smoking women with adenocarcinomas (ADCs), but 30% of mutations occurred in current/ex-smoking men. EGFR-M+ tumours were non-mucinous ADCs and 100% thyroid transcription factor (TTF1+). No mutations were detected in poorly differentiated NSCLC-not otherwise specified (NOS). There was a trend for improved overall survival (OS) among EGFR-M+ versus EGFR-M- patients (median OS=78 versus 17 months). In year 1, test failure rate was 19%, and associated with scant cellularity and low DNA concentrations. However 75% of samples with poor cellularity but representative of tumour were informative and mutation prevalence was 9%. In year 2, 755 samples were tested; mutation prevalence was 13% and test failure only 5.4%. Although samples with low DNA concentration (<2 ng/μL) had more test failures (30% versus 3.9% for [DNA]>2.2 ng/μL), the mutation rate was 9.2%. Routine epidermal growth factor receptor (EGFR) screening using diagnostic samples is fast and feasible even on samples with poor cellularity and DNA content. Mutations tend to occur in better-differentiated non-mucinous TTF1+ ADCs. Whether these histological criteria may be useful to select patients for EGFR testing merits further investigation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Psychometrics properties of early trauma inventory self report - short form (ETISR-SR) for the Brazilian context.

    PubMed

    Osório, Flávia L; Salum, Giovanni Abrahão; Donadon, Mariana Fortunata; Forni-Dos-Santos, Larissa; Loureiro, Sonia Regina; Crippa, José Alexandre S

    2013-01-01

    This study aims to translate and validate Early Trauma Inventory Self Report -Short Form (ETISR-SF) to Brazilian Portuguese. 253 adult subjects answered the ETISR-SF, Beck Anxiety Inventory (BAI), Fagerström Test for Nicotine Dependence (FTND), Patient Health Questionnaire (PHQ-9) and Fast Alcohol Screening Test (FAST). The instrument showed good internal consistency (0.83). Correlations with the PHQ-9 and BAI were moderate (r=0.26-0.47) and showed the expected associations with psychiatric constructs. No associations were found for FTND and FAST. Confirmatory Factor Analysis revealed that a correlated four-factor model as well as a second order model subsuming four lower order components presented the best model fit. Test-retest reliability was also excellent (ICC=0.78-0.90). ETISR-SF is suitable for assessing traumatic experiences in a Brazilian community sample. Given the importance of trauma as a public health problem, tools such as ETISR-SF may help clinicians/ researchers to better evaluate and measure such events and further advance clinical care of trauma victims.

  5. Screening hybridomas for anabolic androgenic steroids by steroid analog antigen microarray.

    PubMed

    Du, Hongwu; Chen, Guangyu; Bian, Yongzhong; Xing, Cenzan; Ding, Xue; Zhu, Mengliang; Xun, Yiping; Chen, Peng; Zhou, Yabin; Li, Shaoxu

    2015-01-01

    Currently, dozens of anabolic androgenic steroids (AAS) are forbidden in the World Anti-Doping Agency Prohibited List, however, despite extensive investigation, there are still lots of AAS without corresponding monoclonal antibodies. A steroid analog antigen microarray made up of ten AAS was fabricated to screen the hybridoma and it was found an original unsuccessful clone turned out to be a candidate anti-boldenone antibody, without any cross-reactions with endogenous AAS or 44 different AAS standard reference materials tested. Our findings suggested that steroid analog antigen microarray could be a promising tool to screen and characterize new applications of antibodies for structure analogs, and this also exhibits the potential to fast identify effective epitopes of hybridomas in a single assay.

  6. Pediatric FAST and elevated liver transaminases: An effective screening tool in blunt abdominal trauma.

    PubMed

    Sola, Juan E; Cheung, Michael C; Yang, Relin; Koslow, Starr; Lanuti, Emma; Seaver, Chris; Neville, Holly L; Schulman, Carl I

    2009-11-01

    The current standard for the evaluation of children with blunt abdominal trauma (BAT) consists of physical examination, screening lab values, and computed tomography (CT) scan. We sought to determine if the focused assessment with sonography for trauma (FAST) combined with elevated liver transaminases (AST/ALT) could be used as a screening tool for intra-abdominal injury (IAI) in pediatric patients with BAT. Registry data at a level 1 trauma center was retrospectively reviewed from 1991-2007. Data collected on BAT patients under the age of 16 y included demographics, injury mechanism, ISS, GCS, imaging studies, serum ALT and AST levels, and disposition. AST and ALT were considered positive if either one was >100 IU/L. Overall, 3171 cases were identified. A total of 1008 (31.8%) patients received CT scan, 1148 (36.2%) had FAST, and 497 (15.7%) patients received both. Of the 497 patients, 400 (87.1%) also had AST and ALT measured. FAST was 50% sensitive, 91% specific, with a positive predictive value (PPV) of 68%, negative predictive value (NPV) of 83%, and accuracy of 80%. Combining FAST with elevated AST or ALT resulted in a statistically significant increase in all measures (sensitivity 88%, specificity 98%, PPV 94%, NPV 96%, accuracy 96%). FAST combined with AST or ALT > 100 IU/L is an effective screening tool for IAI in children following BAT. Pediatric patients with a negative FAST and liver transaminases < 100 IU/L should be observed rather than subjected to the radiation risk of CT.

  7. Fast Centrifugal Partition Chromatography Fractionation of Concentrated Agave (Agave salmiana) Sap to Obtain Saponins with Apoptotic Effect on Colon Cancer Cells.

    PubMed

    Santos-Zea, Liliana; Fajardo-Ramírez, Oscar R; Romo-López, Irasema; Gutiérrez-Uribe, Janet A

    2016-03-01

    Separation of potentially bioactive components from foods and plant extracts is one of the main challenges for their study. Centrifugal partition chromatography has been a successful technique for the screening and identification of molecules with bioactive potential, such as steroidal saponins. Agave is a source of steroidal saponins with anticancer potential, though the activity of these compounds in concentrated agave sap has not been yet explored. In this study, fast centrifugal partition chromatography (FCPC) was used coupled with in vitro tests on HT-29 cells as a screening procedure to identify apoptotic saponins from an acetonic extract of concentrated agave sap. The three most bioactive fractions obtained by FCPC at partition coefficients between 0.23 and 0.4 contained steroidal saponins, predominantly magueyoside b. Flow cytometry analysis determined that the fraction rich in kammogenin and manogenin glycosides induced apoptosis, but when gentrogenin and hecogenin glycosides were also found in the fraction, a necrotic effect was observed. In conclusion, this study provides the evidence that steroidal saponins in concentrated agave sap were potential inductors of apoptosis and that it was possible to separate them using fast centrifugal partition chromatography.

  8. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    PubMed

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  9. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  10. Prevalence of Metabolic Syndrome and Associations with Lipid Profiles in Iranian Men: A Population-Based Screening Program.

    PubMed

    Mohammadbeigi, Abolfazl; Farahani, Hamid; Moshiri, Esmail; Sajadi, Mahbobeh; Ahmadli, Robabeh; Afrashteh, Sima; Khazaei, Salman; Ansari, Hossein

    2018-01-01

    Metabolic syndrome (MS) is characterized by a collection of interdependent disorders, including abdominal obesity, dyslipidemia, hyperglycemia, hypertension, and diabetes. The current study aimed to estimate the prevalence of MS in Qom, Iran. A population-based screening program was conducted in the city of Qom, in 845 urban adult men over 25 years old in 2014. Abdominal obesity, fasting blood glucose (FBG), blood pressure, and the serum lipid profile were measured in subjects after fasting for at least 8 hours. MS was defined according to the Adult Treatment Panel III criteria. Data were analyzed using the chi-square test, t-test, and multiple logistic regression. The overall prevalence of MS was 23.0%, and the most common prevalent metabolic abnormalities associated with MS were low high-density lipoprotein cholesterol (<40 mg/dL) in 34.3% of subjects, a waist circumference >102 cm in 33.9%, blood pressure ≥130/85 mmHg in 27.6%, fasting triglycerides (TG) ≥150 mg/dL in 25%, and FBG ≥110 mg/dL in 20.6%. A FBG level ≥110 mg/dL (odds ratio [OR]=4.85; 95% confidence interval [CI], 2.14~8.24), dyslipidemia (OR=3.51; 95% CI, 2.10~5.89), and a fasting TG ≥150 mg/dL were the most important factors contributing to MS. The prevalence of MS in men in Qom was higher than has been reported in other countries, but it was lower than the mean values that have been reported elsewhere in Iran. FBG was the most important factor contributing to MS, and all elements of the lipid profile showed important associations with MS. Copyright © 2017 Korean Society for Sexual Medicine and Andrology

  11. Prevalence of Metabolic Syndrome and Associations with Lipid Profiles in Iranian Men: A Population-Based Screening Program

    PubMed Central

    2018-01-01

    Purpose Metabolic syndrome (MS) is characterized by a collection of interdependent disorders, including abdominal obesity, dyslipidemia, hyperglycemia, hypertension, and diabetes. The current study aimed to estimate the prevalence of MS in Qom, Iran. Materials and Methods A population-based screening program was conducted in the city of Qom, in 845 urban adult men over 25 years old in 2014. Abdominal obesity, fasting blood glucose (FBG), blood pressure, and the serum lipid profile were measured in subjects after fasting for at least 8 hours. MS was defined according to the Adult Treatment Panel III criteria. Data were analyzed using the chi-square test, t-test, and multiple logistic regression. Results The overall prevalence of MS was 23.0%, and the most common prevalent metabolic abnormalities associated with MS were low high-density lipoprotein cholesterol (<40 mg/dL) in 34.3% of subjects, a waist circumference >102 cm in 33.9%, blood pressure ≥130/85 mmHg in 27.6%, fasting triglycerides (TG) ≥150 mg/dL in 25%, and FBG ≥110 mg/dL in 20.6%. A FBG level ≥110 mg/dL (odds ratio [OR]=4.85; 95% confidence interval [CI], 2.14~8.24), dyslipidemia (OR=3.51; 95% CI, 2.10~5.89), and a fasting TG ≥150 mg/dL were the most important factors contributing to MS. Conclusions The prevalence of MS in men in Qom was higher than has been reported in other countries, but it was lower than the mean values that have been reported elsewhere in Iran. FBG was the most important factor contributing to MS, and all elements of the lipid profile showed important associations with MS. PMID:29164829

  12. [Suitability of screening for diabetes mellitus in women with a history of gestational diabetes].

    PubMed

    Álvarez-Silvares, E; Domínguez-Vigo, P; Domínguez-Sánchez, J; González-González, A

    To assess long-term suitability of screening for type 2 diabetes mellitus in women with a previous diagnosis of gestational diabetes in Primary Care. The secondary objectives were to determine if there were clinical factors that modified the usefulness of the screening. An observational cohort type study was performed, which included all patients with the diagnosis of gestational diabetes during the years 2000 to 2009 (n=470) in the University Hospital Complex of Ourense. The electronic medical records were reviewed to assess the existence of gestational diabetes and the year of the last fasting blood glucose. The mean follow-up time was 12.9 years. The screening for evidence of a fasting blood glucose in the last 3 years was considered adequate. The following variables were analysed: adequacy of screening for type 2 diabetes mellitus, age, body mass index, gestational diabetes in more than one gestation, and rural/urban environment. A descriptive analysis of the data was performed, using Chi2 and Student's t-test to determine differences between subgroups. Statistical significance was considered as P<.05 RESULTS: The long-term monitoring of these patients was very irregular. Only 67.08% of the study group underwent diabetes mellitus type 2 screening. The level of follow-up was not associated with age, BMI, the place of residence, or the year of diagnosis. In patients with more than one episode of gestational diabetes, subsequent blood glucose control was achieved in 94.1%. The adequacy of the screening in our area is very irregular and highly improvable. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Usefulness of non-fasting lipid parameters in children.

    PubMed

    Kubo, Toshihide; Takahashi, Kyohei; Furujo, Mahoko; Hyodo, Yuki; Tsuchiya, Hiroki; Hattori, Mariko; Fujinaga, Shoko; Urayama, Kenji

    2017-01-01

    This study assessed whether non-fasting lipid markers could be substituted for fasting markers in screening for dyslipidemia, whether direct measurement of non-fasting low-density lipoprotein cholesterol [LDL-C (D)] could be substituted for the calculation of fasting LDL-C [LDL-C (F)], and the utility of measuring non-high-density lipoprotein cholesterol (non-HDL-C). In 33 children, the lipid profile was measured in the non-fasting and fasting states within 24 h. Correlations were examined between non-fasting LDL-C (D) or non-HDL-C levels and fasting LDL-C (F) levels. Non-fasting triglyceride (TG), total cholesterol (TC), HDL-C, LDL-C (D), and non-HDL-C levels were all significantly higher than the fasting levels, but the mean difference was within 10% (except for TG). Non-fasting LDL-C (D) and non-HDL-C levels were strongly correlated with the fasting LDL-C (F) levels. In conclusion, except for TG, non-fasting lipid parameters are useful when screening children for dyslipidemia. Direct measurement of non-fasting LDL-C and calculation of non-fasting non-HDL-C could replace the calculation of fasting LDL-C because of convenience.

  14. Chlamydia trachomatis infection: the efficacy and safety of a fast-track referral and treatment system.

    PubMed

    Sethupathi, M; Blackwell, A

    2009-03-01

    We introduced a Nurse/Health Advisor-led fast-track service for treating patients diagnosed with chlamydia outside a genitourinary medicine setting and contacts of chlamydia/non-specific urethritis/cervicitis wherever diagnosed. Asymptomatic patients were treated without initial testing and asked to return for full screening at four to six weeks. We assessed the efficacy and safety of the system and need for follow-up after treatment. Case-notes of 226 patients (121 men and 105 women) were analysed, of whom 140 attended follow-up. With the exception of one case of gonorrhoea, no other serious sexually transmitted infection was detected. Twenty-seven (19.2%) patients were re-treated for either chlamydia (six patients, 4.4%) or non-specific genital infection or because of having unprotected intercourse with untreated or partially treated partners. We conclude that in our relatively low-risk population, our fast-track service is safe and effective. Test of cure for chlamydia seems essential because of the high percentage of patients requiring re-treatment.

  15. Biological variability of transferrin saturation and unsaturated iron binding capacity

    PubMed Central

    Adams, PC; Reboussin, DM; Press, RD; Barton, JC; Acton, RT; Moses, GC; Leiendecker-Foster, C; McLaren, GD; Dawkins, FW; Gordeuk, VR; Lovato, L; Eckfeldt, JH

    2007-01-01

    Background Transferrin saturation is widely considered the preferred screening test for hemochromatosis. Unsaturated iron binding capacity has similar performance at lower cost. However, the within-person biological variability of both these tests may limit their ability at commonly used cut points to detect HFE C282Y homozygous patients. Methods The Hemochromatosis and Iron Overload Screening (HEIRS) Study screened 101,168 primary care participants for iron overload using tansferrin saturation, unsaturated iron binding capacity, ferritin and HFE C282Y and H63D genotyping. Transferrin saturation and unsaturated iron binding capacity were performed at initial screening and again when selected participants and controls returned for a clinical examination several months later. A missed case was defined as a C282Y homozygote who had transferrin saturation below cut point (45 % women, 50 % men) or unsaturated iron binding capacity above cut point (150 μmol/L women, 125 μmol/L men) at either the initial screening or clinical examination, or both, regardless of serum ferritin. Results There were 209 C282Y previously undiagnosed homozygotes with transferrin saturation and unsaturated iron binding capacity testing done at initial screening and clinical examination. Sixty-eight C282Y homozygotes (33%) would have been missed at these transferrin saturation cut points (19 men, 49 women, median SF 170 μg/L, first and third quartiles 50 and 474 μg/L), and 58 homozygotes (28 %) would have been missed at the unsaturated iron binding capacity cut points (20 men, 38 women, median SF 168 μg/L, quartiles 38 and 454 μg/L). There was no advantage to using fasting samples. Conclusions The within-person biological variability of transferrin saturation and unsaturated iron binding capacity limit their usefulness as an initial screening test for expressing C282Y homozygotes. PMID:17976429

  16. Fast nuclear staining of head hair roots as a screening method for successful STR analysis in forensics.

    PubMed

    Lepez, Trees; Vandewoestyne, Mado; Van Hoofstat, David; Deforce, Dieter

    2014-11-01

    The success rate of STR profiling of hairs found at a crime scene is quite low and negative results of hair analysis are frequently reported. To increase the success rate of DNA analysis of hairs in forensics, nuclei in hair roots can be counted after staining the hair root with DAPI. Two staining methods were tested: a longer method with two 1h incubations in respectively a DAPI- and a wash-solution, and a fast, direct staining of the hair root on microscope slides. The two staining methods were not significantly different. The results of the STR analysis for both procedures showed that 20 nuclei are necessary to obtain at least partial STR profiles. When more than 50 nuclei were counted, full STR profiles were always obtained. In 96% of the cases where no nuclei were detected, no STR profile could be obtained. However, 4% of the DAPI-negative hair roots resulted in at least partial STR profiles. Therefore, each forensic case has to be evaluated separately in function of the importance of the evidential value of the found hair. The fast staining method was applied in 36 forensic cases on 279 hairs in total. A fast screening method using DAPI can be used to increase the success rate of hair analysis in forensics. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  17. A 12-week randomized clinical trial investigating the potential for sucralose to affect glucose homeostasis.

    PubMed

    Grotz, V Lee; Pi-Sunyer, Xavier; Porte, Daniel; Roberts, Ashley; Richard Trout, J

    2017-08-01

    The discovery of gut sweet taste receptors has led to speculations that non-nutritive sweeteners, including sucralose, may affect glucose control. A double-blind, parallel, randomized clinical trial, reported here and previously submitted to regulatory agencies, helps to clarify the role of sucralose in this regard. This was primarily an out-patient study, with 4-week screening, 12-week test, and 4-week follow-up phases. Normoglycemic male volunteers (47) consumed ∼333.3 mg encapsulated sucralose or placebo 3x/day at mealtimes. HbA1c, fasting glucose, insulin, and C-peptide were measured weekly. OGTTs were conducted in-clinic overnight, following overnight fasting twice during screening phase, twice during test phase, and once at follow-up. Throughout the study, glucose, insulin, C-peptide and HbA1c levels were within normal range. No statistically significant differences between sucralose and placebo groups in change from baseline for fasting glucose, insulin, C-peptide and HbA1c, no clinically meaningful differences in time to peak levels or return towards basal levels in OGTTs, and no treatment group differences in mean glucose, insulin, or C-peptide AUC change from baseline were observed. The results of other relevant clinical trials and studies of gastrointestinal sweet taste receptors are compared to these findings. The collective evidence supports that sucralose has no effect on glycemic control. Copyright © 2017 Heartland Food Products Group. Published by Elsevier Inc. All rights reserved.

  18. Scoring the home falls and accidents screening tool for health professionals (HOME FAST-HP): Evidence from one epidemiological study.

    PubMed

    Mackenzie, Lynette; Byles, Julie

    2018-03-30

    Falls in older people are a major public health concern. To target falls prevention interventions, screening tools need to be able to identify older people at greater risk of falling. This study aimed to investigate the screening capacity of the Home Falls and Accidents Screening Tool for health professionals (HOME FAST-HP), and to identify the best cut-off score to identify older people at higher risk of falls using the HOME FAST-HP. The study used cross-sectional data from a random sample of 650 women from the 1921 to 1926 cohort of the Australian Longitudinal Study of Women's Health (ALSWH). Selected women were sent a postal survey including the HOME FAST-HP, falls history, and other health factors. Scores on the home fast were calculated and the cut-point for optimal sensitivity and specificity of the HOME FAST-HP in relation to falls was assessed using a Receiver Operating Characteristic curve. A total of 567 older women participated (response rate 87%). The mean age of participants was 77.5 yrs (95% CI 77.31-77.70). A total of 153 participants (27%) reported a fall in the previous six months. The mean number of hazards using the HOME FAST-HP was 9.74 (95% CI 9.48-10.01), range 2-22. Non-fallers had a mean of 9.6 hazards (95% CI 9.32-9.91) and fallers had a mean of 10.63 hazards (95% CI 10.08-11.19) which was a significant difference (t = 3.41, P = 0.001). The area under the receiver operator curve (AUC) was 0.58 (95% CI 0.53-0.64). A HOME FAST-HP cut-off score of 9 was associated with the optimal sensitivity for falls (73.9%), with specificity (37.9%), and positive predictive value was 30.6% and negative predictive value was 79.7%. The HOME FAST-HP can be used as a screening tool to identify fallers with a cut-off score of nine indicating a higher risk of falling. © 2018 Occupational Therapy Australia.

  19. Diagnostic accuracy of self-administered urine glucose test strips as a diabetes screening tool in a low-resource setting in Cambodia.

    PubMed

    Storey, Helen L; van Pelt, Maurits H; Bun, Socheath; Daily, Frances; Neogi, Tina; Thompson, Matthew; McGuire, Helen; Weigl, Bernhard H

    2018-03-22

    Screening for diabetes in low-resource countries is a growing challenge, necessitating tests that are resource and context appropriate. The aim of this study was to determine the diagnostic accuracy of a self-administered urine glucose test strip compared with alternative diabetes screening tools in a low-resource setting of Cambodia. Prospective cross-sectional study. Members of the Borey Santepheap Community in Cambodia (Phnom Penh Municipality, District Dangkao, Commune Chom Chao). All households on randomly selected streets were invited to participate, and adults at least 18 years of age living in the study area were eligible for inclusion. The accuracy of self-administered urine glucose test strip positivity, Hemoglobin A1c (HbA1c)>6.5% and capillary fasting blood glucose (cFBG) measurement ≥126 mg/dL were assessed against a composite reference standard of cFBGmeasurement ≥200 mg/dL or venous blood glucose 2 hours after oral glucose tolerance test (OGTT) ≥200 mg/dL. Of the 1289 participants, 234 (18%) had diabetes based on either cFBG measurement (74, 32%) or the OGTT (160, 68%). The urine glucose test strip was 14% sensitive and 99% specific and failed to identify 201 individuals with diabetes while falsely identifying 7 without diabetes. Those missed by the urine glucose test strip had lower venous fasting blood glucose, lower venous blood glucose 2 hours after OGTT and lower HbA1c compared with those correctly diagnosed. Low cost, easy to use diabetes tools are essential for low-resource communities with minimal infrastructure. While the urine glucose test strip may identify persons with diabetes that might otherwise go undiagnosed in these settings, its poor sensitivity cannot be ignored. The massive burden of diabetes in low-resource settings demands improvements in test technologies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Recent developments in genetics and medically assisted reproduction: from research to clinical applications.

    PubMed

    Harper, J C; Aittomäki, K; Borry, P; Cornel, M C; de Wert, G; Dondorp, W; Geraedts, J; Gianaroli, L; Ketterson, K; Liebaers, I; Lundin, K; Mertes, H; Morris, M; Pennings, G; Sermon, K; Spits, C; Soini, S; van Montfoort, A P A; Veiga, A; Vermeesch, J R; Viville, S; Macek, M

    2018-01-01

    Two leading European professional societies, the European Society of Human Genetics and the European Society for Human Reproduction and Embryology, have worked together since 2004 to evaluate the impact of fast research advances at the interface of assisted reproduction and genetics, including their application into clinical practice. In September 2016, the expert panel met for the third time. The topics discussed highlighted important issues covering the impacts of expanded carrier screening, direct-to-consumer genetic testing, voiding of the presumed anonymity of gamete donors by advanced genetic testing, advances in the research of genetic causes underlying male and female infertility, utilisation of massively parallel sequencing in preimplantation genetic testing and non-invasive prenatal screening, mitochondrial replacement in human oocytes, and additionally, issues related to cross-generational epigenetic inheritance following IVF and germline genome editing. The resulting paper represents a consensus of both professional societies involved.

  1. Whole-organism screening for gluconeogenesis identifies activators of fasting metabolism

    PubMed Central

    Gut, Philipp; Baeza-Raja, Bernat; Andersson, Olov; Hasenkamp, Laura; Hsiao, Joseph; Hesselson, Daniel; Akassoglou, Katerina; Verdin, Eric; Hirschey, Matthew D.; Stainier, Didier Y.R.

    2012-01-01

    Improving the control of energy homeostasis can lower cardiovascular risk in metabolically compromised individuals. To identify new regulators of whole-body energy control, we conducted a high-throughput screen in transgenic reporter zebrafish for small molecules that modulate the expression of the fasting-inducible gluconeogenic gene pck1. We show that this in vivo strategy identified several drugs that impact gluconeogenesis in humans, as well as metabolically uncharacterized compounds. Most notably, we find that the Translocator Protein (TSPO) ligands PK 11195 and Ro5-4864 are glucose lowering agents despite a strong inductive effect on pck1 expression. We show that these drugs are activators of a fasting-like energy state, and importantly that they protect high-fat diet induced obese mice from hepatosteatosis and glucose intolerance, two pathological manifestations of metabolic dysregulation. Thus, using a whole-organism screening strategy, this study has identified new small molecule activators of fasting metabolism. PMID:23201900

  2. A Predictive Metabolic Signature for the Transition From Gestational Diabetes Mellitus to Type 2 Diabetes.

    PubMed

    Allalou, Amina; Nalla, Amarnadh; Prentice, Kacey J; Liu, Ying; Zhang, Ming; Dai, Feihan F; Ning, Xian; Osborne, Lucy R; Cox, Brian J; Gunderson, Erica P; Wheeler, Michael B

    2016-09-01

    Gestational diabetes mellitus (GDM) affects 3-14% of pregnancies, with 20-50% of these women progressing to type 2 diabetes (T2D) within 5 years. This study sought to develop a metabolomics signature to predict the transition from GDM to T2D. A prospective cohort of 1,035 women with GDM pregnancy were enrolled at 6-9 weeks postpartum (baseline) and were screened for T2D annually for 2 years. Of 1,010 women without T2D at baseline, 113 progressed to T2D within 2 years. T2D developed in another 17 women between 2 and 4 years. A nested case-control design used 122 incident case patients matched to non-case patients by age, prepregnancy BMI, and race/ethnicity. We conducted metabolomics with baseline fasting plasma and identified 21 metabolites that significantly differed by incident T2D status. Machine learning optimization resulted in a decision tree modeling that predicted T2D incidence with a discriminative power of 83.0% in the training set and 76.9% in an independent testing set, which is far superior to measuring fasting plasma glucose levels alone. The American Diabetes Association recommends T2D screening in the early postpartum period via oral glucose tolerance testing after GDM, which is a time-consuming and inconvenient procedure. Our metabolomics signature predicted T2D incidence from a single fasting blood sample. This study represents the first metabolomics study of the transition from GDM to T2D validated in an independent testing set, facilitating early interventions. © 2016 by the American Diabetes Association.

  3. A Predictive Metabolic Signature for the Transition From Gestational Diabetes Mellitus to Type 2 Diabetes

    PubMed Central

    Allalou, Amina; Nalla, Amarnadh; Prentice, Kacey J.; Liu, Ying; Zhang, Ming; Dai, Feihan F.; Ning, Xian; Osborne, Lucy R.; Cox, Brian J.

    2016-01-01

    Gestational diabetes mellitus (GDM) affects 3–14% of pregnancies, with 20–50% of these women progressing to type 2 diabetes (T2D) within 5 years. This study sought to develop a metabolomics signature to predict the transition from GDM to T2D. A prospective cohort of 1,035 women with GDM pregnancy were enrolled at 6–9 weeks postpartum (baseline) and were screened for T2D annually for 2 years. Of 1,010 women without T2D at baseline, 113 progressed to T2D within 2 years. T2D developed in another 17 women between 2 and 4 years. A nested case-control design used 122 incident case patients matched to non–case patients by age, prepregnancy BMI, and race/ethnicity. We conducted metabolomics with baseline fasting plasma and identified 21 metabolites that significantly differed by incident T2D status. Machine learning optimization resulted in a decision tree modeling that predicted T2D incidence with a discriminative power of 83.0% in the training set and 76.9% in an independent testing set, which is far superior to measuring fasting plasma glucose levels alone. The American Diabetes Association recommends T2D screening in the early postpartum period via oral glucose tolerance testing after GDM, which is a time-consuming and inconvenient procedure. Our metabolomics signature predicted T2D incidence from a single fasting blood sample. This study represents the first metabolomics study of the transition from GDM to T2D validated in an independent testing set, facilitating early interventions. PMID:27338739

  4. Balance and gait in children with dyslexia.

    PubMed

    Moe-Nilssen, Rolf; Helbostad, Jorunn L; Talcott, Joel B; Toennessen, Finn Egil

    2003-05-01

    Tests of postural stability have provided some evidence of a link between deficits in gross motor skills and developmental dyslexia. The ordinal-level scales used previously, however, have limited measurement sensitivity, and no studies have investigated motor performance during walking in participants with dyslexia. The purpose of this study was to investigate if continuous-scaled measures of standing balance and gait could discriminate between groups of impaired and normal readers when investigators were blind to group membership during testing. Children with dyslexia ( n=22) and controls ( n=18), aged 10-12 years, performed walking tests at four different speeds (slow-preferred-fast-very fast) on an even and an uneven surface, and tests of unperturbed and perturbed body sway during standing. Body movements were registered by a triaxial accelerometer over the lower trunk, and measures of reaction time, body sway, walking speed, step length and cadence were calculated. Results were controlled for gender differences. Tests of standing balance with eyes closed did not discriminate between groups. All unperturbed standing tests with eyes open showed significant group differences ( P<0.05) and classified correctly 70-77.5% of the subjects into their respective groups. Mean walking speed during very fast walking on both flat and uneven surface was > or =0.2 m/s ( P< or =0.01) faster for controls than for the group with dyslexia. This test classified 77.5% and 85% of the subjects correctly on flat and uneven surface, respectively. Cadence at preferred or very fast speed did not differ statistically between groups, but revealed significant group differences when all subjects were compared at a normalised walking speed ( P< or =0.04). Very fast walking speed as well as cadence at a normalised speed discriminated better between groups when subjects were walking on an uneven surface compared to a flat floor. Continuous-scaled walking tests performed in field settings may be suitable for motor skill assessment as a component of a screening tool for developmental dyslexia.

  5. Survey of South African fruit juices using a fast screening HILIC-MS method.

    PubMed

    Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F

    2013-01-01

    Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.

  6. The reliability of in-hospital diagnoses of diabetes mellitus in the setting of an acute myocardial infarction.

    PubMed

    Arnold, Suzanne V; Lipska, Kasia J; Inzucchi, Silvio E; Li, Yan; Jones, Philip G; McGuire, Darren K; Goyal, Abhinav; Stolker, Joshua M; Lind, Marcus; Spertus, John A; Kosiborod, Mikhail

    2014-01-01

    Incident diabetes mellitus (DM) is important to recognize in patients with acute myocardial infarction (AMI). To develop an efficient screening strategy, we explored the use of random plasma glucose (RPG) at admission and fasting plasma glucose (FPG) to select patients with AMI for glycosylated hemoglobin (HbA1c) testing. Prospective registry of 1574 patients with AMI not taking glucose-lowering medication from 24 US hospitals. All patients had HbA1c measured at a core laboratory and admission RPG and ≥2 FPGs recorded during hospitalization. We examined potential combinations of RPG and FPG and compared these with HbA1c≥6.5%-considered the gold standard for DM diagnosis in these analyses. An RPG>140 mg/dL or FPG≥126 mg/dL had high sensitivity for DM diagnosis. Combining these into a screening protocol (if admission RPG>140, check HbA1c; or if FPG≥126 on a subsequent day, check HbA1c) led to HbA1c testing in 50% of patients and identified 86% with incident DM (number needed to screen (NNS)=3.3 to identify 1 case of DM; vs NNS=5.6 with universal HbA1c screening). Alternatively, using an RPG>180 led to HbA1c testing in 40% of patients with AMI and identified 82% of DM (NNS=2.7). We have established two potential selective screening methods for DM in the setting of AMI that could identify the vast majority of incident DM by targeted screening of 40-50% of patients with AMI with HbA1c testing. Using these methods may efficiently identify patients with AMI with DM so that appropriate education and treatment can be promptly initiated.

  7. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren.

    PubMed

    Kim, Min Sun; Lee, Dae Yeol

    2017-06-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. © 2017 The Korean Academy of Medical Sciences.

  8. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren

    PubMed Central

    2017-01-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. PMID:28480657

  9. Screening of lysosomal storage disorders: application of the online trapping-and-cleanup liquid chromatography/mass spectrometry method for mucopolysaccharidosis I.

    PubMed

    Ombrone, Daniela; Malvagia, Sabrina; Funghini, Silvia; Giocaliere, Elisa; Della Bona, Maria Luisa; Forni, Giulia; De Luca, Alessio; Villanelli, Fabio; Casetta, Bruno; Guerrini, Renzo; la Marca, Giancarlo

    2013-01-01

    In recent years, new treatments have become available to treat some lysosomal storage disorders (LSDs) and many studies suggest that there is a benefit with starting therapy early. Newborn screening should detect diseases early enough for prompt treatment. Some countries include additional conditions, such as some LSDs, into their newborn screening panels. Mucopolysaccharidosis Type I (MPS I) is an autosomal recessive disorder caused by the deficiency of α-L-iduronidase (IDUA) activity. Currently, enzyme replacement therapy (ERT) or bone marrow transplantation is available and this has raised a growing interest for the development of a newborn screening test. In 2009, we reported a new fast and simplified tandem mass spectrometry-based method for quantifying five enzyme activities on dried blood spots. Here, we describe the inclusion of IDUA activity determination for the simultaneous detection of six lysosomal storage diseases. We have defined reference normal ranges by testing 680 healthy newborns and 240 adults. The assay was checked through three confirmed MPS I patients whose IDUA activity was below the normal range. Reproducibility of the assays has been established by assessing the intra-day and inter-day assay imprecisions. This quick assay has been devised to be implemented in newborn screening by liquid chromatography tandem mass spectrometry.

  10. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry I. Screening analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Avois, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2009-05-15

    The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.

  11. Fast mass spectrometry-based enantiomeric excess determination of proteinogenic amino acids.

    PubMed

    Fleischer, Heidi; Thurow, Kerstin

    2013-03-01

    A rapid determination of the enantiomeric excess of proteinogenic amino acids is of great importance in various fields of chemical and biologic research and industries. Owing to their different biologic effects, enantiomers are interesting research subjects in drug development for the design of new and more efficient pharmaceuticals. Usually, the enantiomeric composition of amino acids is determined by conventional analytical methods such as liquid or gas chromatography or capillary electrophoresis. These analytical techniques do not fulfill the requirements of high-throughput screening due to their relative long analysis times. The method presented allows a fast analysis of chiral amino acids without previous time consuming chromatographic separation. The analytical measurements base on parallel kinetic resolution with pseudoenantiomeric mass tagged auxiliaries and were carried out by mass spectrometry with electrospray ionization. All 19 chiral proteinogenic amino acids were tested and Pro, Ser, Trp, His, and Glu were selected as model substrates for verification measurements. The enantiomeric excesses of amino acids with non-polar and aliphatic side chains as well as Trp and Phe (aromatic side chains) were determined with maximum deviations of the expected value less than or equal to 10ee%. Ser, Cys, His, Glu, and Asp were determined with deviations lower or equal to 14ee% and the enantiomeric excess of Tyr were calculated with 17ee% deviation. The total screening process is fully automated from the sample pretreatment to the data processing. The method presented enables fast measurement times about 1.38 min per sample and is applicable in the scope of high-throughput screenings.

  12. Prestack depth migration for complex 2D structure using phase-screen propagators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, P.; Huang, Lian-Jie; Burch, C.

    1997-11-01

    We present results for the phase-screen propagator method applied to prestack depth migration of the Marmousi synthetic data set. The data were migrated as individual common-shot records and the resulting partial images were superposed to obtain the final complete Image. Tests were performed to determine the minimum number of frequency components required to achieve the best quality image and this in turn provided estimates of the minimum computing time. Running on a single processor SUN SPARC Ultra I, high quality images were obtained in as little as 8.7 CPU hours and adequate images were obtained in as little as 4.4more » CPU hours. Different methods were tested for choosing the reference velocity used for the background phase-shift operation and for defining the slowness perturbation screens. Although the depths of some of the steeply dipping, high-contrast features were shifted slightly the overall image quality was fairly insensitive to the choice of the reference velocity. Our jests show the phase-screen method to be a reliable and fast algorithm for imaging complex geologic structures, at least for complex 2D synthetic data where the velocity model is known.« less

  13. Fast correction approach for wavefront sensorless adaptive optics based on a linear phase diversity technique.

    PubMed

    Yue, Dan; Nie, Haitao; Li, Ye; Ying, Changsheng

    2018-03-01

    Wavefront sensorless (WFSless) adaptive optics (AO) systems have been widely studied in recent years. To reach optimum results, such systems require an efficient correction method. This paper presents a fast wavefront correction approach for a WFSless AO system mainly based on the linear phase diversity (PD) technique. The fast closed-loop control algorithm is set up based on the linear relationship between the drive voltage of the deformable mirror (DM) and the far-field images of the system, which is obtained through the linear PD algorithm combined with the influence function of the DM. A large number of phase screens under different turbulence strengths are simulated to test the performance of the proposed method. The numerical simulation results show that the method has fast convergence rate and strong correction ability, a few correction times can achieve good correction results, and can effectively improve the imaging quality of the system while needing fewer measurements of CCD data.

  14. Response to fifty grams oral glucose challenge test and pattern of preceding fasting plasma glucose in normal pregnant Nigerians.

    PubMed

    Adegbola, Omololu; Ajayi, Godwin Olufemi

    2014-03-01

    Diabetes mellitus in pregnancy has profound implications for the baby and mother and thus active screening for this is desirable. Fifty grams oral glucose challenge test was administered after obtaining consent to 222 women in good health with singleton pregnancies without diabetes mellitus at 24 to 28 weeks gestation after an overnight fast. Venous blood sample was obtained before and 1 hour after the glucose load. A diagnostic 3-hour 100 g oral glucose tolerance test was subsequently performed in all. Two hundred and ten women had a normal response to oral glucose tolerance test i.e. venous plasma glucose below these cut-off levels: fasting 95 mg/dl (5.3 mmol/l), 1 hour 180 mg/dl (10.0 mmol/l), 2 hours 155 mg/dl (8.6 mmol/l) and 3 hours 140 mg/dl (7.8 mmol/l), while 12 were found to have gestational diabetes mellitus and were subsequently excluded from the study. They were appropriately managed. The mean maternal age was 30.9 ± 4.1 years (range 19 to 45 years) and the mean parity was 1.2 ± 1.1 (range 0 to 5). The mean fasting plasma glucose was 74.5 ± 11.5 mg/dl (range 42 to 117 mg/dl), while the mean plasma glucose 1 hour after 50 g glucose challenge test was 115.3 ± 19.1 mg/dl (range 56 to 180 mg/dl). The mean fasting plasma glucose in normal pregnant Nigerians was 74.5 ± 11.5 mg/dl (range 42 to 117 mg/dl). There is a need to re-appraise and possibly review downwards the World Health Organization fasting plasma glucose diagnostic criteria in pregnant Nigerians for better detection of gestational diabetes mellitus. Pregnant women with venous plasma glucose greater than 153.5 mg/dl (8.5 mmol/l) 1 hour after 50 g glucose challenge test are strongly recommended for diagnostic test of gestational diabetes mellitus.

  15. Fast Neutron Tomography of Low-Z Object in High-Z Material Shielding

    NASA Astrophysics Data System (ADS)

    Babai, Ruth Weiss; Sabo-Napadensky, Iris; Bar, Doron; Mor, Ilan; Tamim, Noam; Dangendorf, Volker; Tittelmeier, Kai; Bromberger, Benjamin; Weierganz, Mathias

    The technique and first results of Fast Neutron Tomography (FNCT) experiments are presented which are performed at the accelerator facility of PTB, Germany. A high-intensity neutron beam of broad spectral distribution with an average energy of 5.5 MeV, was produced by 11.5 MeV deuterons impinging upon a thick beryllium target. The capability of FNCT for high contrast imaging of low-Z materials embedded in thick high-Z shielding materials is demonstrated, which is superior to more conventional high-energy X-ray imaging techniques. For demonstrating the method special test objects were prepared: One consisted of an assembled polyethylene cylinder with holes of various diameters and directions drilled in its surface and inner parts. The plastic phantom was inserted into lead cylinders of different thicknesses. The detector system consisted of a plastic scintillator along with a dedicated optics, image-intensifier and a CCD camera. Two scintillator screens were compared: a bulk plastic scintillator screen and a fibres optical scintillator screen. The tomographic scans were taken in two geometrical configurations: cone beam and semi-fan beam configuration. The image quality favours the semi-fan beam configuration which on the other hand is more time consuming The obtained tomographic images and a comparison of the imaging quality between the different experimental conditions will be presented.

  16. Preventing Infectious Pulmonary Tuberculosis Among Foreign-Born Residents of the United States

    PubMed Central

    Katz, Dolly; Ghosh, Smita; Blumberg, Henry; Tamhane, Ashutosh; Sevilla, Anna; Reves, Randall

    2015-01-01

    Objectives. We described risk factors associated with infectious tuberculosis (TB) and missed TB-prevention opportunities in foreign-born US residents, who account for almost two thirds of the nation’s TB patients. Methods. In a cross-sectional study at 20 US sites of foreign-born persons diagnosed with TB in 2005 through 2006, we collected results of sputum smear microscopy for acid-fast bacilli (a marker for infectiousness) and data on visa status, sociodemographics, TB-related care seeking, and latent TB infection (LTBI) diagnosis opportunities. Results. Among 980 persons with pulmonary TB who reported their visa status, 601 (61%) were legal permanent residents, 131 (13.4%) had temporary visas, and 248 (25.3%) were undocumented. Undocumented persons were more likely than permanent residents to have acid-fast bacilli–positive smears at diagnosis (risk ratio = 1.3; 95% confidence interval = 1.2, 1.4). Of those diagnosed 1 year or more after arrival, 57.3% reported LTBI screening opportunities; fewer than 25% actually were. Undocumented persons reported fewer LTBI screening opportunities and were less likely to be tested. Conclusions. Progress toward TB elimination in the United States depends upon expanding opportunities for regular medical care and promotion of LTBI screening and treatment among foreign-born persons. PMID:26180947

  17. Development of a rapid screening protocol for selection of strains resistant to spray drying and storage in dry powder.

    PubMed

    Reimann, S; Grattepanche, F; Baggenstos, C; Rezzonico, E; Berger, B; Arigoni, F; Lacroix, C

    2010-06-01

    An efficient screening method for selection of Bifidobacterium longum strains resistant to spray drying and storage was developed based on randomly amplified polymorphic DNA (RAPD) for identification of the best survivors in mixed strains bacterial preparations. Three different primers were used to generate RAPD profiles of 22 B. longum strains. All strains were distinguished according to their RAPD profiles except for the strain NCC2705 and its H(2)O(2) resistant derivative variant. The 22 strains were grouped in 3 batches of 7, 7 and 8 strains and subjected to spray drying and storage at 30 and 37 °C under anaerobic conditions. Batch survival rates after spray drying reached 17.1±4.4%. Strains showing the highest prevalence and/or resistance to storage at 37 °C were selected from individual batches for subsequent spray drying and storage testing. After 67 days of storage, NCC572 was identified as the dominant strain in powder. The stability of strain NCC572 was confirmed by performing single spray drying and storage tests. Out of 22 B. longum strains, a robust strain was identified by combining RAPD with a simultaneous screening test for survival under spray drying and storage. The method allowed a fast screening of B. longum strains in mixture for resistance to spray drying and storage compared to traditional screening procedures carried out with individual strains, in the same conditions. This approach could be applied to other stress conditions.

  18. [Prenatal risk calculation: comparison between Fast Screen pre I plus software and ViewPoint software. Evaluation of the risk calculation algorithms].

    PubMed

    Morin, Jean-François; Botton, Eléonore; Jacquemard, François; Richard-Gireme, Anouk

    2013-01-01

    The Fetal medicine foundation (FMF) has developed a new algorithm called Prenatal Risk Calculation (PRC) to evaluate Down syndrome screening based on free hCGβ, PAPP-A and nuchal translucency. The peculiarity of this algorithm is to use the degree of extremeness (DoE) instead of the multiple of the median (MoM). The biologists measuring maternal seric markers on Kryptor™ machines (Thermo Fisher Scientific) use Fast Screen pre I plus software for the prenatal risk calculation. This software integrates the PRC algorithm. Our study evaluates the data of 2.092 patient files of which 19 show a fœtal abnormality. These files have been first evaluated with the ViewPoint software based on MoM. The link between DoE and MoM has been analyzed and the different calculated risks compared. The study shows that Fast Screen pre I plus software gives the same risk results as ViewPoint software, but yields significantly fewer false positive results.

  19. A Rapid and Efficient Screening Method for Antibacterial Compound-Producing Bacteria.

    PubMed

    Hettiarachchi, Sachithra; Lee, Su-Jin; Lee, Youngdeuk; Kwon, Young-Kyung; De Zoysa, Mahanama; Moon, Song; Jo, Eunyoung; Kim, Taeho; Kang, Do-Hyung; Heo, Soo-Jin; Oh, Chulhong

    2017-08-28

    Antibacterial compounds are widely used in the treatment of human and animal diseases. The overuse of antibiotics has led to a rapid rise in the prevalence of drug-resistant bacteria, making the development of new antibacterial compounds essential. This study focused on developing a fast and easy method for identifying marine bacteria that produce antibiotic compounds. Eight randomly selected marine target bacterial species ( Agrococcus terreus, Bacillus algicola, Mesoflavibacter zeaxanthinifaciens, Pseudoalteromonas flavipulchra, P. peptidolytica, P. piscicida, P. rubra , and Zunongwangia atlantica ) were tested for production of antibacterial compounds against four strains of test bacteria ( B. cereus, B. subtilis, Halomonas smyrnensis , and Vibrio alginolyticus ). Colony picking was used as the primary screening method. Clear zones were observed around colonies of P. flavipulchra, P. peptidolytica, P. piscicida , and P. rubra tested against B. cereus, B. subtilis , and H. smyrnensis . The efficiency of colony scraping and broth culture methods for antimicrobial compound extraction was also compared using a disk diffusion assay. P. peptidolytica, P. piscicida , and P. rubra showed antagonistic activity against H. smyrnensis, B. cereus , and B. subtilis , respectively, only in the colony scraping method. Our results show that colony picking and colony scraping are effective, quick, and easy methods of screening for antibacterial compound-producing bacteria.

  20. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  1. Screening with HbA1c identifies only one in two individuals with diagnosis of prediabetes at oral glucose tolerance test: findings in a real-world Caucasian population.

    PubMed

    Chilelli, Nino Cristiano; Cosma, Chiara; Ragazzi, Eugenio; Burlina, Silvia; Zaninotto, Martina; Plebani, Mario; Lapolla, Annunziata

    2014-10-01

    Discordance between HbA1c and OGTT in screening pre-diabetes may occur because of lack of laboratory standardization, distinct underlying pathophysiological processes or different ethnicity. We evaluated HbA1c efficacy for screening OGTT-defined IFG and IGT conditions in a large Caucasian population using the newly revised IFCC protocol. A total of 501 consecutive subjects were screened for pre-diabetic conditions with OGTT with 75 g of glucose. Testing for HbA1c, lipid profile and fasting insulin levels was also performed. For detecting differences between continuous variables, ANOVA followed by Tukey's honestly significant difference (HSD) post hoc test was used. Logistic regression and ROC curve analysis were also performed for assessing HbA1c screening efficacy. ROC curve analysis showed that optimal HbA1c cut-off for detecting IFG was 5.6 % (sensitivity of 78 % and specificity of 63 %), while for IGT, the optimal cut-off was 5.9 % (sensitivity of 46 % and specificity of 84 %), with AUCs < 0.8. Screening with HbA1c identified 53.4 % of the 193 patients with IFG and/or IGT diagnosed at OGTT. As regards surrogate markers of insulin resistance, we observed a trend towards higher values of HOMA-IR and lower QUICKI values in subjects with IFG than in those with IGT. Patients with pre-diabetes at both tests had similar values of HOMA and QUICKI, compared with those with altered OGTT only. IFCC-aligned HbA1c assay proved scarcely effective in detecting IFG and/or IGT in a large Caucasian population, identifying only half of the patients with abnormal OGTT. Moreover, adding HbA1c screening to OGTT may be of little benefit in identifying subjects with a worse metabolic profile.

  2. Prediction of Stereochemistry using Q2MM

    PubMed Central

    2016-01-01

    Conspectus The standard method of screening ligands for selectivity in asymmetric, transition metal-catalyzed reactions requires experimental testing of hundreds of ligands from ligand libraries. This “trial and error” process is costly in terms of time as well as resources and, in general, is scientifically and intellectually unsatisfying as it reveals little about the underlying mechanism behind the selectivity. The accurate computational prediction of stereoselectivity in enantioselective catalysis requires adequate conformational sampling of the selectivity-determining transition state but has to be fast enough to compete with experimental screening techniques to be useful for the synthetic chemist. Although electronic structure calculations are accurate and general, they are too slow to allow for sampling or fast screening of ligand libraries. The combined requirements can be fulfilled by using appropriately fitted transition state force fields (TSFFs) that represent the transition state as a minimum and allow fast conformational sampling using Monte Carlo. Quantum-guided molecular mechanics (Q2MM) is an automated force field parametrization method that generates accurate, reaction-specific TSFFs by fitting the functional form of an arbitrary force field using only electronic structure calculations by minimization of an objective function. A key feature that distinguishes the Q2MM method from many other automated parametrization procedures is the use of the Hessian matrix in addition to geometric parameters and relative energies. This alleviates the known problems of overfitting of TSFFs. After validation of the TSFF by comparison to electronic structure results for a test set and available experimental data, the stereoselectivity of a reaction can be calculated by summation over the Boltzman-averaged relative energies of the conformations leading to the different stereoisomers. The Q2MM method has been applied successfully to perform virtual ligand screens on a range of transition metal-catalyzed reactions that are important from both an industrial and an academic perspective. In this Account, we provide an overview of the continued improvement of the prediction of stereochemistry using Q2MM-derived TSFFs using four examples from different stages of development: (i) Pd-catalyzed allylation, (ii) OsO4-catalyzed asymmetric dihydroxylation (AD) of alkenes, (iii) Rh-catalyzed hydrogenation of enamides, and (iv) Ru-catalyzed hydrogenation of ketones. In the current form, correlation coefficients of 0.8–0.9 between calculated and experimental ee values are typical for a wide range of substrate–ligand combinations, and suitable ligands can be predicted for a given substrate with ∼80% accuracy. Although the generation of a TSFF requires an initial effort and will therefore be most useful for widely used reactions that require frequent screening campaigns, the method allows for a rapid virtual screen of large ligand libraries to focus experimental efforts on the most promising substrate–ligand combinations. PMID:27064579

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winther, Hans A.; Koyama, Kazuya; Wright, Bill S.

    We present a general parallelized and easy-to-use code to perform numerical simulations of structure formation using the COLA (COmoving Lagrangian Acceleration) method for cosmological models that exhibit scale-dependent growth at the level of first and second order Lagrangian perturbation theory. For modified gravity theories we also include screening using a fast approximate method that covers all the main examples of screening mechanisms in the literature. We test the code by comparing it to full simulations of two popular modified gravity models, namely f ( R ) gravity and nDGP, and find good agreement in the modified gravity boost-factors relative tomore » ΛCDM even when using a fairly small number of COLA time steps.« less

  4. Performance of Fasting Plasma Glucose and Postprandial Urine Glucose in Screening for Diabetes in Chinese High-risk Population

    PubMed Central

    Yang, Bing-Quan; Lu, Yang; He, Jia-Jia; Wu, Tong-Zhi; Xie, Zuo-Ling; Lei, Cheng-Hao; Zhou, Yi; Han, Jing; Bian, Mei-Qi; You, Hong; Mei, De-Xian; Sun, Zi-Lin

    2015-01-01

    Background: The conventional approaches to diabetes screening are potentially limited by poor compliance and laboratory demand. This study aimed to evaluate the performance of fasting plasma glucose (FPG) and postprandial urine glucose (PUG) in screening for diabetes in Chinese high-risk population. Methods: Nine hundred and nine subjects with high-risk factors of diabetes underwent oral glucose tolerance test after an overnight fast. FPG, hemoglobin A1c, 2-h plasma glucose (2 h-PG), and 2 h-PUG were evaluated. Diabetes and prediabetes were defined by the American Diabetes Association criteria. The area under the receiver operating characteristic (ROC) curve was used to evaluate the diagnostic accuracy of 2 h-PUG, and the optimal cut-off determined to provide the largest Youden index. Spearman correlation was used for relationship analysis. Results: Among 909 subjects, 33.4% (304/909) of subjects had prediabetes, and 17.2% (156/909) had diabetes. The 2 h-PUG was positively related to FPG and 2 h-PG (r = 0.428 and 0.551, respectively, both P < 0.001). For estimation of 2 h-PG ≥ 7.8 mmol/L and 2 h-PG ≥ 11.1 mmol/L using 2 h-PUG, the area under the ROC curve were 0.772 (95% confidence interval [CI ]: 0.738–0.806) and 0.885 (95% CI: 0.850–0.921), respectively. The corresponding optimal cut-offs for 2 h-PUG were 5.6 mmol/L and 7.5 mmol/L, respectively. Compared with FPG alone, FPG combined with 2 h-PUG had a higher sensitivity for detecting glucose abnormalities (84.1% vs. 73.7%, P < 0.001) and diabetes (82.7% vs. 48.1%, P < 0.001). Conclusion: FPG combined with 2 h-PUG substantially improves the sensitivity in detecting prediabetes and diabetes relative to FPG alone, and may represent an efficient layperson-oriented diabetes screening method. PMID:26668139

  5. Performance of Fasting Plasma Glucose and Postprandial Urine Glucose in Screening for Diabetes in Chinese High-risk Population.

    PubMed

    Yang, Bing-Quan; Lu, Yang; He, Jia-Jia; Wu, Tong-Zhi; Xie, Zuo-Ling; Lei, Cheng-Hao; Zhou, Yi; Han, Jing; Bian, Mei-Qi; You, Hong; Mei, De-Xian; Sun, Zi-Lin

    2015-12-20

    The conventional approaches to diabetes screening are potentially limited by poor compliance and laboratory demand. This study aimed to evaluate the performance of fasting plasma glucose (FPG) and postprandial urine glucose (PUG) in screening for diabetes in Chinese high-risk population. Nine hundred and nine subjects with high-risk factors of diabetes underwent oral glucose tolerance test after an overnight fast. FPG, hemoglobin A1c, 2-h plasma glucose (2 h-PG), and 2 h-PUG were evaluated. Diabetes and prediabetes were defined by the American Diabetes Association criteria. The area under the receiver operating characteristic (ROC) curve was used to evaluate the diagnostic accuracy of 2 h-PUG, and the optimal cut-off determined to provide the largest Youden index. Spearman correlation was used for relationship analysis. Among 909 subjects, 33.4% (304/909) of subjects had prediabetes, and 17.2% (156/909) had diabetes. The 2 h-PUG was positively related to FPG and 2 h-PG (r = 0.428 and 0.551, respectively, both P < 0.001). For estimation of 2 h-PG ≥ 7.8 mmol/L and 2 h-PG ≥ 11.1 mmol/L using 2 h-PUG, the area under the ROC curve were 0.772 (95% confidence interval [CI ]: 0.738-0.806) and 0.885 (95% CI: 0.850-0.921), respectively. The corresponding optimal cut-offs for 2 h-PUG were 5.6 mmol/L and 7.5 mmol/L, respectively. Compared with FPG alone, FPG combined with 2 h-PUG had a higher sensitivity for detecting glucose abnormalities (84.1% vs. 73.7%, P < 0.001) and diabetes (82.7% vs. 48.1%, P < 0.001). FPG combined with 2 h-PUG substantially improves the sensitivity in detecting prediabetes and diabetes relative to FPG alone, and may represent an efficient layperson-oriented diabetes screening method.

  6. Prevalence of HIV in pregnant women identified with a risk factor at a tertiary care hospital.

    PubMed

    Mahmud, Ghazala; Abbas, Shazra

    2009-01-01

    HIV is an epidemic quite unlike any other, combining the problems of a lifelong medical disease with immense social, psychological, economic and public health consequences. Since we are living in a global village where human interactions has become fast and frequent, diseases like HIV are no more alien to us. HIV/AIDS in Pakistan is slowly gaining recognition as a public health issue of great importance. Objectives of this study were to determine the prevalence of HIV in pregnant women identified with a high risk factor/behaviour at a tertiary care hospital. It is a Descriptive study. All pregnant women attending antenatal booking clinic were assessed via a pre-designed 'Risk assessment questionnaire'. Women identified with a risk factor were offered HIV Rapid screening test (Capillus HIV1/2). Positive (reactive) results on screening test were confirmed with ELISA. During the study period (March 2007-May 2008), out of 5263 antenatal bookings 785 (14%) women were identified with a risk factor. HIV screening test was done in 779 (99%), and 6 women refused testing. Three women (0.3%) were found positive (reactive) on screening. Two out of 3 women were confirmed positive (0.2%) on ELISA. Husbands of both women were tested and one found positive (migrant from Dubai). Second women had history of blood transfusion. Her husband was HIV negative. During the study period, in addition to 2 pregnant women diagnosed as HIV positive through ANC risk screening, 6 confirmed HIV positive women, found pregnant were referred from 'HIV Treatment Centre', Pakistan Institute of Medical Sciences (PIMS) to Prevention of Parent to Child Transmission (PPTCT) centre for obstetric care. Spouses of 5 out of 6 had history of working abroad and extramarital sexual relationships. All positive (8) women were referred to PPTCT centre for further management. A simple 'Risk Assessment Questionnaire' can help us in identifying women who need HIV screening. Sexual transmission still remains the commonest cause of HIV transmission.

  7. Outcome and cost of a statewide diabetes screening and awareness initiative in New York.

    PubMed

    Hosler, Akiko S; Berberian, Elizabeth L; Spence, Maureen M; Hoffman, David P

    2005-01-01

    From 1997 through 1999, a total of 365 diabetes screening and awareness events targeting high-risk populations were held throughout New York State. These events were planned and implemented by community-based coalitions that received funding from the state's Diabetes Control Program. The American Diabetes Association's diabetes risk questionnaire was administered, and those individuals identified as high risk received a capillary blood glucose test. Screened individuals with glucose readings above the cut-off value (140 mg/dl or 110 mg/dl if fasting) were referred to a physician for diagnostic testing. A total of 32,954 individuals took the questionnaire, 27,237 received the blood test, and 1,564 were referred to a physician. Among those who were successfully tracked (n = 1,113), 354 were newly diagnosed with diabetes mellitus. Seventy-two percent of participants screened were aged 45 years and older, and 67% had a body mass index of 25 or higher. Only 15% were members of ethnic minorities, and uninsured individuals were also underrepresented at 10%. The entire initiative, including planning, promotion, and administration, required 5,428 person-hours of staff time and a total cost of approximately 262,000 dollars. Fifty-seven percent of the total cost was derived from in-kind support of the coalitions. The cost of detecting each new case was 741 dollars.

  8. Shifting from glucose diagnostic criteria to the new HbA(1c) criteria would have a profound impact on prevalence of diabetes among a high-risk Spanish population.

    PubMed

    Costa, B; Barrio, F; Cabré, J-J; Piñol, J-L; Cos, F-X; Solé, C; Bolibar, B; Castell, C; Lindström, J; Barengo, N; Tuomilehto, J

    2011-10-01

    To investigate changes in the prevalence of diabetes and pre-diabetes by shifting from 2-h plasma glucose and/or fasting plasma glucose diagnostic criteria to the proposed new HbA(1c) -based criteria when applied to a Mediterranean population detected to have a high risk of Type 2 diabetes. Individuals without diabetes aged 45-75 years (n = 2287) were screened using the Finnish Diabetes Risk Score questionnaire, a 2-h oral glucose tolerance test plus HbA(1c) test. Prevalence and degree of diagnostic overlap between three sets of criteria (2-h plasma glucose, fasting plasma glucose and HbA(1c) ) and three diagnostic categories (normal, pre-diabetes and diabetes) were calculated. Defining diabetes by a single HbA(1c) measurement resulted in a dramatic decrease in prevalence (1.3%), particularly in comparison with diabetes defined by 2-h plasma glucose (8.6%), but was also significant with regard to fasting plasma glucose (2.8%). A total of 201 screened subjects (8.8%) were classified as having diabetes and 1023 (44.7%) as having pre-diabetes based on at least one of these criteria; among these, the presence of all three criteria simultaneously classified only 21 and 110 individuals respectively, about ten percent of each group. The single overlap index between subjects diagnosed as having diabetes by 2-h plasma glucose/fasting plasma glucose vs. HbA(1c) was 13.9/28%. Similarly, the single overlap index regarding pre-diabetes was 19.2/27.1%. A shift from the glucose-based diagnosis to the HbA(1c) -based diagnosis for diabetes will reduce diabetes prevalence with a low overall or single degree of overlap between diagnostic categories in this high-risk Spanish population. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  9. Type 2 diabetes mellitus in Navajo adolescents.

    PubMed Central

    Kim, C; McHugh, C; Kwok, Y; Smith, A

    1999-01-01

    Diabetes mellitus afflicts over one-fifth of the Navajo population aged over 20 years, but the prevalence of diabetes in Navajo adolescents is unclear. We conducted voluntary testing for diabetes mellitus at two high schools on the Navajo reservation to clarify the prevalence as well as to assess the utility of a high-school based screening program. Body mass index measurements (BMI), oral glucose tolerance tests, and hemoglobin A1C measurements were obtained in consenting high school students. Of the 276 students that participated, 234 were Navajo. Only one Navajo student (0.4%) had diabetes mellitus, although eight (3%) had impaired glucose tolerance or impaired fasting glucose. Participant BMI did not differ significantly from nonparticipant BMI. No correlation existed between BMI or impaired glucose handling, and significant overlap existed between the hemoglobin A1C values of students with impaired glucose handling and students without impaired glucose handling. Increased participation in screening programs may reveal higher disease prevalence, but high school-based screening is not justified by this study, despite the high rates of diabetes mellitus in the Navajo population. PMID:10344174

  10. Genarris: Random generation of molecular crystal structures and fast screening with a Harris approximation

    NASA Astrophysics Data System (ADS)

    Li, Xiayue; Curtis, Farren S.; Rose, Timothy; Schober, Christoph; Vazquez-Mayagoitia, Alvaro; Reuter, Karsten; Oberhofer, Harald; Marom, Noa

    2018-06-01

    We present Genarris, a Python package that performs configuration space screening for molecular crystals of rigid molecules by random sampling with physical constraints. For fast energy evaluations, Genarris employs a Harris approximation, whereby the total density of a molecular crystal is constructed via superposition of single molecule densities. Dispersion-inclusive density functional theory is then used for the Harris density without performing a self-consistency cycle. Genarris uses machine learning for clustering, based on a relative coordinate descriptor developed specifically for molecular crystals, which is shown to be robust in identifying packing motif similarity. In addition to random structure generation, Genarris offers three workflows based on different sequences of successive clustering and selection steps: the "Rigorous" workflow is an exhaustive exploration of the potential energy landscape, the "Energy" workflow produces a set of low energy structures, and the "Diverse" workflow produces a maximally diverse set of structures. The latter is recommended for generating initial populations for genetic algorithms. Here, the implementation of Genarris is reported and its application is demonstrated for three test cases.

  11. Environmental screening tools for assessment of infrastructure plans based on biodiversity preservation and global warming (PEIT, Spain)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Montero, Luis G., E-mail: luisgonzaga.garcia@upm.e; Lopez, Elena, E-mail: elopez@caminos.upm.e; Monzon, Andres, E-mail: amonzon@caminos.upm.e

    Most Strategic Environmental Assessment (SEA) research has been concerned with SEA as a procedure, and there have been relatively few developments and tests of analytical methodologies. The first stage of the SEA is the 'screening', which is the process whereby a decision is taken on whether or not SEA is required for a particular programme or plan. The effectiveness of screening and SEA procedures will depend on how well the assessment fits into the planning from the early stages of the decision-making process. However, it is difficult to prepare the environmental screening for an infrastructure plan involving a whole country.more » To be useful, such methodologies must be fast and simple. We have developed two screening tools which would make it possible to estimate promptly the overall impact an infrastructure plan might have on biodiversity and global warming for a whole country, in order to generate planning alternatives, and to determine whether or not SEA is required for a particular infrastructure plan.« less

  12. LC-NMR Technique in the Analysis of Phytosterols in Natural Extracts

    PubMed Central

    Horník, Štěpán; Sajfrtová, Marie; Sýkora, Jan; Březinová, Anna; Wimmer, Zdeněk

    2013-01-01

    The ability of LC-NMR to detect simultaneously free and conjugated phytosterols in natural extracts was tested. The advantages and disadvantages of a gradient HPLC-NMR method were compared to the fast composition screening using SEC-NMR method. Fractions of free and conjugated phytosterols were isolated and analyzed by isocratic HPLC-NMR methods. The results of qualitative and quantitative analyses were in a good agreement with the literature data. PMID:24455424

  13. A Comparison of the Baseline Metabolic Profiles between Diabetes Prevention Trial-Type 1 and TrialNet Natural History Study Participants

    PubMed Central

    Sosenko, Jay M.; Mahon, Jeffrey; Rafkin, Lisa; Lachin, John M.; Krause-Steinrauf, Heidi; Krischer, Jeffrey P.; Cuthbertson, David; Palmer, Jerry P.; Thompson, Clinton; Greenbaum, Carla J.; Skyler, Jay S.

    2010-01-01

    Objective We assessed whether differing autoantibody screening criteria for type 1 diabetes (T1D) prevention trials result in different baseline metabolic profiles of those who screen positive. Methods Diabetes Prevention Trial-Type 1 (DPT-1) participants were screened for islet cell autoantibodies (ICA), whereas TrialNet Natural History Study (TNNHS) participants were screened for biochemical autoantibodies. In both studies, those determined to be autoantibody positive underwent baseline oral glucose tolerance tests (OGTTs) in which glucose and C-peptide were measured. Results The percentage of those with an OGTT in the diabetic range was higher among the DPT-1 participants (10.0% of 956 vs. 6.4% of 645, p<0.01). In a logistic regression analysis with adjustments for age and gender, the difference persisted (p<0.01). Among those in the non-diabetic range (n=860 for DPT-1 and n=604 for the TNNHS), glucose levels were similar at all time points, except for higher fasting glucose levels in the TNNHS participants (p<0.001). There was a higher percentage of impaired fasting glucose in the TNNHS participants (10.9% vs. 6.7%, p<0.01); however, with adjustments for age and gender, there was no longer a significant difference. There was no significant difference in the percentages with IGT. C-peptide levels were much lower in the DPT-1 cohort at all OGTT time points (p<0.001 for all). Discussion Differing criteria for autoantibody screening can result in marked differences in the baseline metabolic profiles of prospective participants of T1D prevention trials. PMID:20522170

  14. A comparison of the baseline metabolic profiles between Diabetes Prevention Trial-Type 1 and TrialNet Natural History Study participants.

    PubMed

    Sosenko, Jay M; Mahon, Jeffrey; Rafkin, Lisa; Lachin, John M; Krause-Steinrauf, Heidi; Krischer, Jeffrey P; Cuthbertson, David; Palmer, Jerry P; Thompson, Clinton; Greenbaum, Carla J; Skyler, Jay S

    2011-03-01

    We assessed whether differing autoantibody screening criteria for type 1 diabetes (T1D) prevention trials result in different baseline metabolic profiles of those who screen positive. Diabetes Prevention Trial-Type 1 (DPT-1) participants were screened for islet cell autoantibodies, whereas TrialNet Natural History Study (TNNHS) participants were screened for biochemical autoantibodies. In both studies, those determined to be autoantibody positive underwent baseline oral glucose tolerance tests (OGTTs) in which glucose and C-peptide were measured. The percentage of those with an OGTT in the diabetic range was higher among the DPT-1 participants (10.0% of 956 vs. 6.4% of 645, p < 0.01). In a logistic regression analysis with adjustments for age and gender, the difference persisted (p < 0.01). Among those in the non-diabetic range (n = 860 for DPT-1 and n = 604 for the TNNHS), glucose levels were similar at all time points, except for higher fasting glucose levels in the TNNHS participants (p < 0.001). There was a higher percentage of impaired fasting glucose (IFG) in the TNNHS participants (10.9 vs. 6.7%, p < 0.01); however, with adjustments for age and gender, there was no longer a significant difference. There was no significant difference in the percentages with impaired glucose tolerance. C-peptide levels were much lower in the DPT-1 cohort at all OGTT time points (p < 0.001 for all). Differing criteria for autoantibody screening can result in marked differences in the baseline metabolic profiles of prospective participants of T1D prevention trials. © 2010 John Wiley & Sons A/S.

  15. Is the number of fast-food outlets in the neighbourhood related to screen-detected type 2 diabetes mellitus and associated risk factors?

    PubMed

    Bodicoat, Danielle H; Carter, Patrice; Comber, Alexis; Edwardson, Charlotte; Gray, Laura J; Hill, Sian; Webb, David; Yates, Thomas; Davies, Melanie J; Khunti, Kamlesh

    2015-06-01

    We investigated whether a higher number of fast-food outlets in an individual's home neighbourhood is associated with increased prevalence of type 2 diabetes mellitus and related risk factors, including obesity. Cross-sectional study. Three UK-based diabetes screening studies (one general population, two high-risk populations) conducted between 2004 and 2011. The primary outcome was screen-detected type 2 diabetes. Secondary outcomes were risk factors for type 2 diabetes. In total 10 461 participants (mean age 59 years; 53% male; 21% non-White ethnicity). There was a higher number of neighbourhood (500 m radius from home postcode) fast-food outlets among non-White ethnic groups (P<0.001) and in socially deprived areas (P<0.001). After adjustment (social deprivation, urban/rural, ethnicity, age, sex), more fast-food outlets was associated with significantly increased odds for diabetes (OR=1.02; 95% CI 1.00, 1.04) and obesity (OR=1.02; 95% CI 1.00, 1.03). This suggests that for every additional two outlets per neighbourhood, we would expect one additional diabetes case, assuming a causal relationship between the fast-food outlets and diabetes. These results suggest that increased exposure to fast-food outlets is associated with increased risk of type 2 diabetes and obesity, which has implications for diabetes prevention at a public health level and for those granting planning permission to new fast-food outlets.

  16. Validation of a Type 2 Diabetes Screening Tool in Rural Honduras

    PubMed Central

    Milton, Evan C.; Herman, William H.; Aiello, Allison E.; Danielson, Kris R.; Mendoza-Avelarez, Milton O.; Piette, John D.

    2010-01-01

    OBJECTIVE To validate a low-cost tool for identifying diabetic patients in rural areas of Latin America. RESEARCH DESIGN AND METHODS A regression equation incorporating postprandial time and a random plasma glucose was used to screen 800 adults in Honduras. Patients with a probability of diabetes of ≥20% were asked to return for a fasting plasma glucose (FPG). A random fifth of those with a screener-based probability of diabetes <20% were also asked to return for follow-up. The gold standard was an FPG ≥126 mg/dl. RESULTS The screener had very good test characteristics (area under the receiver operating characteristic curve = 0.89). Using the screening criterion of ≥0.42, the equation had a sensitivity of 74.1% and specificity of 97.2%. CONCLUSIONS This screener is a valid measure of diabetes risk in Honduras and could be used to identify diabetic patients in poor clinics in Latin America. PMID:19918008

  17. An evaluation of malingering screens with competency to stand trial patients: a known-groups comparison.

    PubMed

    Vitacco, Michael J; Rogers, Richard; Gabel, Jason; Munizza, Janice

    2007-06-01

    The assessment of malingering is a fundamental component of forensic evaluations that should be considered with each referral. In systematizing the evaluation of malingering, one option is the standardized administration of screens as an initial step. The current study assessed the effectiveness of three common screening measures: the Miller Forensic Assessment of Symptoms Test (M-FAST; Miller, 2001), the Structured Inventory of Malingered Symptomatology (SIMS; Widows & Smith, 2004), and the Evaluation of Competency to Stand Trial-Revised Atypical Presentation Scale (ECST-R ATP; Rogers, Tillbrook, & Sewell, 2004). Using the Structured Interview of Reported Symptoms (SIRS) as the external criterion, 100 patients involved in competency to stand trial evaluations were categorized as either probable malingerers (n=21) or nonmalingerers (n=79). Each malingering scale produced robust effect sizes in this known-groups comparison. Results are discussed in relation to the comprehensive assessment of malingering within a forensic context.

  18. FMM-Yukawa: An adaptive fast multipole method for screened Coulomb interactions

    NASA Astrophysics Data System (ADS)

    Huang, Jingfang; Jia, Jun; Zhang, Bo

    2009-11-01

    A Fortran program package is introduced for the rapid evaluation of the screened Coulomb interactions of N particles in three dimensions. The method utilizes an adaptive oct-tree structure, and is based on the new version of fast multipole method in which the exponential expansions are used to diagonalize the multipole-to-local translations. The program and its full description, as well as several closely related packages are also available at http://www.fastmultipole.org/. This paper is a brief review of the program and its performance. Catalogue identifier: AEEQ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEQ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPL 2.0 No. of lines in distributed program, including test data, etc.: 12 385 No. of bytes in distributed program, including test data, etc.: 79 222 Distribution format: tar.gz Programming language: Fortran77 and Fortran90 Computer: Any Operating system: Any RAM: Depends on the number of particles, their distribution, and the adaptive tree structure Classification: 4.8, 4.12 Nature of problem: To evaluate the screened Coulomb potential and force field of N charged particles, and to evaluate a convolution type integral where the Green's function is the fundamental solution of the modified Helmholtz equation. Solution method: An adaptive oct-tree is generated, and a new version of fast multipole method is applied in which the "multipole-to-local" translation operator is diagonalized. Restrictions: Only three and six significant digits accuracy options are provided in this version. Unusual features: Most of the codes are written in Fortran77. Functions for memory allocation from Fortran90 and above are used in one subroutine. Additional comments: For supplementary information see http://www.fastmultipole.org/ Running time: The running time varies depending on the number of particles (denoted by N) in the system and their distribution. The running time scales linearly as a function of N for nearly uniform particle distributions. For three digits accuracy, the solver breaks even with direct summation method at about N = 750. References: [1] L. Greengard, J. Huang, A new version of the fast multipole method for screened Coulomb interactions in three dimensions, J. Comput. Phys. 180 (2002) 642-658.

  19. Occult pneumothorax in trauma patients: should this be sought in the focused assessment with sonography for trauma examination?

    PubMed

    Tam, Michael M K

    2005-01-01

    At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.

  20. A Review on Glycosylated Hemoglobin in Polycystic Ovary Syndrome.

    PubMed

    Rezaee, Mohsen; Asadi, Nasrin; Pouralborz, Yasna; Ghodrat, Mahshid; Habibi, Shaghayegh

    2016-12-01

    Polycystic ovary syndrome (PCOS) is one of the most common reproductive endocrine disorders among women of reproductive age, with a variety of complications and consequences mostly due to hyperandrogenism and insulin resistance (IR). PCOS patients with IR are at risk for metabolic syndrome and diabetes mellitus (DM) along with its complications such as cardiovascular events. There are several methods for screening IR in patients with PCOS to predict DM and other complications. Fasting plasma glucose test, oral glucose tolerance test, and insulin and glycosylated hemoglobin (HbA1c) levels are some available screening tools for IR. The American Diabetes Association recommended HbA1c to screen for DM because HbA1c is not affected by day-to-day plasma glucose levels and reflects the plasma glucose status during 2-3 months before measurement. Some studies have evaluated the role of HbA1c as a screening method to predict DM in PCOS patients, however, there are still controversies in this matter. Also some studies reported that HbA1c has a correlation with complications of PCOS such as metabolic syndrome and cardiovascular events. We found that HbA1c could be a suitable screening test for IR in PCOS patients but more studies are recommended, omitting confounding factors that could affect IR in patients with PCOS, such as antihyperglycemic agents like metformin, or lifestyle modification, which can be effective in reducing IR in patients with PCOS. Copyright © 2016 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  1. Detection of Carbapenemase Production in a Collection of Enterobacteriaceae with Characterized Resistance Mechanisms from Clinical and Environmental Origins by Use of Both Carba NP and Blue-Carba Tests.

    PubMed

    García-Fernández, Sergio; Morosini, María-Isabel; Gijón, Desirèe; Beatobe, Lorena; Ruiz-Garbajosa, Patricia; Domínguez, Lucas; Cantón, Rafael; Valverde, Aránzazu

    2016-02-01

    Rapid-screening methods to confirm the presence of resistance mechanisms in multidrug-resistant bacteria are currently recommended. Carba NP and Blue-Carba tests were evaluated in carbapenemase-producing Enterobacteriaceae from hospital (n = 102) and environmental (n = 57) origins for detecting the different molecular classes among them. Both methods showed to be fast and cost-effective, with high sensitivity (98% to 100%) and specificity (100%), and may be easily introduced in the routine laboratory. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. How resilient is the soybean genome? Insights from fast neutron mutagenesis

    USDA-ARS?s Scientific Manuscript database

    Previously, we described the development of a fast neutron mutant population resource in soybean and identified mutations of interest through phenotypic screening. Here, we consider the resiliency of the soybean genome by examining genomic rearrangements and mutations that arise from fast neutron ra...

  3. Identification of previously undiagnosed diabetes and prediabetes in the inpatient setting using risk factor and hemoglobin A1C screening.

    PubMed

    Ochoa, Pamella S; Terrell, Brian T; Vega, Jose A; Mnjoyan, Sofia Z; Lu, Celia; Klein, Mary S; Binkley, Gary W

    2014-11-01

    Identifying diabetes early in its progression can present opportunities to intervene with education and medical management to prevent diabetes-related complications. The primary objective was to determine the incidence of diabetes in hospitalized patients without insurance or routine outpatient care using recommendations by the American Diabetes Association (ADA) Standards of Medical Care in Diabetes for diabetes risk screening and diagnosis. This study was conducted at a community hospital in Abilene, Texas. Hospitalized patients were screened if they had self-payer status and did not have a primary care physician. If patients met screening criteria based on risk factors listed in the ADA guidelines, a hemoglobin A1C test and fasting plasma glucose test were completed during hospitalization. Patients found to have diabetes were referred for outpatient education and management of diabetes. Data to determine the incidence of diabetes diagnosis were collected retrospectively. A total of 460 patients were screened for inclusion. Of the 92 patients included in the analysis, 8.7% (n=8) were identified as having diabetes and 39.1% (n=36) with prediabetes. Age and hypertension were independently positively correlated with increased risk for diabetes (P=0.002; P=0.045). Using risk factor screening based on ADA recommendations in the inpatient setting did not identify a significant number of patients with diabetes. This study found specific risk factors to be correlated with diagnosis of diabetes. Rather than using routine screening based on the number of risk factors, the presence of highly correlated risk factors may be an indication for diabetes screening. © The Author(s) 2014.

  4. Ability of immunodiagnostic tests to differentiate between dogs naturally infected with Leishmania infantum and Leishmune(®)-vaccinated dogs.

    PubMed

    Ribeiro, R A N; Teixeira-Neto, R G; Belo, V S; Ferreira, E C; Schallig, H D F H; Silva, E S

    2015-06-01

    Visceral leishmaniasis (VL) is a serious chronic disease with a lethality rate of up to 10% in humans. In urban areas of Brazil, dogs are the main reservoirs of the etiological agent (Leishmania infantum) of VL, and the Brazilian Ministry of Health recommends the euthanasia of animals that are seropositive in both the immunochromatographic dual path platform rapid test (DPP(®); Bio-Manguinhos) and the enzyme-linked immunosorbent assay (ELISA) with an L. major-like antigen (Bio-Manguinhos). Vaccination is an additional tool in the control of canine VL, but the use of Leishmune(®) (Zoetis Indústria de Produtos Veterinários, São Paulo, SP, Brazil), which contains the fucose mannose ligand (FML) isolated from L. donovani, is not currently recommended by the Brazilian Ministry of Health because vaccinated animals may exhibit positive serology and there are reservations regarding the efficacy of the vaccine. The aims of the present study were: (i) to verify the abilities of the fast agglutination screening test (FAST), the direct agglutination test (DAT), the indirect fluorescent-antibody test (IFAT), the DPP rapid test, and ELISA tests with L. major-like and FML antigens to differentiate between L. infantum-infected and Leishmune(®)-vaccinated dogs, and (ii) to analyze the sensitivities and specificities of the different methods. The reactivities to these tests of Leishmune(®)-vaccinated dogs (n = 71), asymptomatic (n = 20) and symptomatic (n = 20) naturally infected dogs, and unvaccinated healthy control dogs (n = 5) were compared. None of the Leishmune(®)-vaccinated dogs tested seropositive in FAST and DAT, although one dog was reactive to DPP and four dogs to ELISA/L. major-like and IFAT tests. While 69 (97%) of vaccinated dogs reacted to ELISA/FML, only one was seropositive in both ELISA/L. major-like and IFAT tests. Individually, all immunodiagnostic tests presented high specificities and positive likelihood ratios (LR+), and high specificity values were obtained when the tests were considered in pairs. However, sensitivity and LR- values were low for ELISA/L. major-like and IFAT tests individually, and for all pair combinations of tests except for FAST with DPP.

  5. Imaging of fast chlorophyll fluorescence induction curve (OJIP) parameters, applied in a screening study with wild barley (Hordeum spontaneum) genotypes under heat stress.

    PubMed

    Jedmowski, Christoph; Brüggemann, Wolfgang

    2015-10-01

    We quantified the influence of heat stress (HS) on PSII by imaging of parameters of the fast chlorophyll fluorescence (CF) induction (OJIP) kinetic of 20 genotypes of wild barley (Hordeum spontaneum) covering a broad geographical spectrum. We developed a standardised screening procedure, allowing a repetitive fluorescence measurement of leaf segments. The impact of HS was quantified by calculating a Heat Resistance Index (HRI), derived from the decrease of the Performance Index (PI) caused by HS treatment and following recovery. For the genotype showing the lowest HRI, reduced maximum quantum yield (φP0) and increased relative variable fluorescence of the O-J phase (K-Peak) were detected after HS, whereas the basal fluorescence (F0) remained stable. An additional feature was a lowered fraction of active (QA-reducing) reaction centres (RCs). The disturbances disappeared after one day of recovery. Spatial heterogeneities of fluorescence parameters were detected, as the negative effect of HS was stronger in the leaf areas close to the leaf tip. The results of this study prove that chlorophyll fluorescence imaging (CFI) is suitable for the detection of HS symptoms and that imaging of JIP-Test parameters should be considered in future screening and phenotyping studies aiming for the characterisation of plant genotypes. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. China’s Ace in the Hole Rare Earth Elements

    DTIC Science & Technology

    2010-01-01

    before losing magnetism. 11 Europium sesquioxide (Eu203) has been tested as neutron absorbers for control rods in (fast breeder ) nuclear reactors ...sources of rare earth around the world, it could take anywhere from 10 to 15 years from the time of discovery to begin a full- scale rare earth...television/computer screens, it is being studied for possible use in nuclear reactors .11 Erbium is used as an amplifier for fiber optic data

  7. Barriers to postpartum screening for type 2 diabetes: a qualitative study of women with previous gestational diabetes.

    PubMed

    Rafii, Forough; Rahimparvar, Seyedeh Fatemeh Vasegh; Mehrdad, Neda; Keramat, Afsaneh

    2017-01-01

    Risk of developing type 2 diabetes is increased in women with previous gestational diabetes mellitus (GDM). Postpartum glycemic screening is recommended in women with recent GDM. But this screening rate is low and the reasons are unclear. The aim of this study was to explore the experiences of Iranian women with recent GDM on barriers of postpartum screening for diabetes. This qualitative study was conducted in Tehran, Iran in 2016. Semi-structured interview was used for data collection. 22 women with recent GDM were interviewed. These women gave birth in Tehran hospitals at a minimum of 6 months before interview. The missed screening defined as not attending to laboratory for Fasting Blood Sugar and/or Oral Glucose Tolerance Test, 6 week to 6 month after their child birthing. The data was analyzed by content analysis method. Themes and sub-themes that illustrated the barriers to postpartum diabetes screening were: inadequate education (about developing diabetes in the future, implementation of the screening, and glucometer validity in diagnosis of diabetes), perceiving the screening as difficult (feeling comfortable with the glucometer, poor laboratory conditions, issues related to the baby/babies, and financial problems), improper attitudes toward the screening (unwilling to get diagnosed, not giving priority to oneself, having false beliefs) and procrastination (gap to intention and action, self-deception and self-regulation failure). Women with recent GDM reported several barriers for postpartum diabetes screening. This study help to develop the evidence-based interventions for improving this screening rate.

  8. Ambulance Clinical Triage for Acute Stroke Treatment: Paramedic Triage Algorithm for Large Vessel Occlusion.

    PubMed

    Zhao, Henry; Pesavento, Lauren; Coote, Skye; Rodrigues, Edrich; Salvaris, Patrick; Smith, Karen; Bernard, Stephen; Stephenson, Michael; Churilov, Leonid; Yassi, Nawaf; Davis, Stephen M; Campbell, Bruce C V

    2018-04-01

    Clinical triage scales for prehospital recognition of large vessel occlusion (LVO) are limited by low specificity when applied by paramedics. We created the 3-step ambulance clinical triage for acute stroke treatment (ACT-FAST) as the first algorithmic LVO identification tool, designed to improve specificity by recognizing only severe clinical syndromes and optimizing paramedic usability and reliability. The ACT-FAST algorithm consists of (1) unilateral arm drift to stretcher <10 seconds, (2) severe language deficit (if right arm is weak) or gaze deviation/hemineglect assessed by simple shoulder tap test (if left arm is weak), and (3) eligibility and stroke mimic screen. ACT-FAST examination steps were retrospectively validated, and then prospectively validated by paramedics transporting culturally and linguistically diverse patients with suspected stroke in the emergency department, for the identification of internal carotid or proximal middle cerebral artery occlusion. The diagnostic performance of the full ACT-FAST algorithm was then validated for patients accepted for thrombectomy. In retrospective (n=565) and prospective paramedic (n=104) validation, ACT-FAST displayed higher overall accuracy and specificity, when compared with existing LVO triage scales. Agreement of ACT-FAST between paramedics and doctors was excellent (κ=0.91; 95% confidence interval, 0.79-1.0). The full ACT-FAST algorithm (n=60) assessed by paramedics showed high overall accuracy (91.7%), sensitivity (85.7%), specificity (93.5%), and positive predictive value (80%) for recognition of endovascular-eligible LVO. The 3-step ACT-FAST algorithm shows higher specificity and reliability than existing scales for clinical LVO recognition, despite requiring just 2 examination steps. The inclusion of an eligibility step allowed recognition of endovascular-eligible patients with high accuracy. Using a sequential algorithmic approach eliminates scoring confusion and reduces assessment time. Future studies will test whether field application of ACT-FAST by paramedics to bypass suspected patients with LVO directly to endovascular-capable centers can reduce delays to endovascular thrombectomy. © 2018 American Heart Association, Inc.

  9. Use of capillary blood glucose for screening for gestational diabetes mellitus in resource-constrained settings.

    PubMed

    Bhavadharini, Balaji; Mahalakshmi, Manni Mohanraj; Maheswari, Kumar; Kalaiyarasi, Gunasekaran; Anjana, Ranjit Mohan; Deepa, Mohan; Ranjani, Harish; Priya, Miranda; Uma, Ram; Usha, Sriram; Pastakia, Sonak D; Malanda, Belma; Belton, Anne; Unnikrishnan, Ranjit; Kayal, Arivudainambi; Mohan, Viswanathan

    2016-02-01

    The aim of the study was to evaluate usefulness of capillary blood glucose (CBG) for diagnosis of gestational diabetes mellitus (GDM) in resource-constrained settings where venous plasma glucose (VPG) estimations may be impossible. Consecutive pregnant women (n = 1031) attending antenatal clinics in southern India underwent 75-g oral glucose tolerance test (OGTT). Fasting, 1- and 2-h VPG (AU2700 Beckman, Fullerton, CA) and CBG (One Touch Ultra-II, LifeScan) were simultaneously measured. Sensitivity and specificity were estimated for different CBG cut points using the International Association of Diabetes in Pregnancy Study Groups (IADPSG) criteria for the diagnosis of GDM as gold standard. Bland-Altman plots were drawn to look at the agreement between CBG and VPG. Correlation and regression equation analysis were also derived for CBG values. Pearson's correlation between VPG and CBG for fasting was r = 0.433 [intraclass correlation coefficient (ICC) = 0.596, p < 0.001], for 1H, it was r = 0.653 (ICC = 0.776, p < 0.001), and for 2H, r = 0.784 (ICC = 0.834, p < 0.001). Comparing a single CBG 2-h cut point of 140 mg/dl (7.8 mmol/l) with the IADPSG criteria, the sensitivity and specificity were 62.3 and 80.7 %, respectively. If CBG cut points of 120 mg/dl (6.6 mmol/l) or 110 mg/dl (6.1 mmol/l) were used, the sensitivity improves to 78.3 and 92.5 %, respectively. In settings where VPG estimations are not possible, CBG can be used as an initial screening test for GDM, using lower 2H CBG cut points to maximize the sensitivity. Those who screen positive can be referred to higher centers for definitive testing, using VPG.

  10. A redox proteomics approach to investigate the mode of action of nanomaterials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riebeling, Christian; Wiemann, Martin; Schnekenburger, Jürgen

    2016-05-15

    Numbers of engineered nanomaterials (ENMs) are steadily increasing. Therefore, alternative testing approaches with reduced costs and high predictivity suitable for high throughput screening and prioritization are urgently needed to ensure a fast and effective development of safe products. In parallel, extensive research efforts are targeted to understanding modes of action of ENMs, which may also support the development of new predictive assays. Oxidative stress is a widely accepted paradigm associated with different adverse outcomes of ENMs. It has frequently been identified in in vitro and in vivo studies and different assays have been developed for this purpose. Fluorescent dye basedmore » read-outs are most frequently used for cell testing in vitro but may be limited due to possible interference of the ENMs. Recently, other assays have been put forward such as acellular determination of ROS production potential using methods like electron spin resonance, antioxidant quantification or the use of specific sensors. In addition, Omics based approaches have gained increasing attention. In particular, redox proteomics can combine the assessment of oxidative stress with the advantage of getting more detailed mechanistic information. Here we propose a comprehensive testing strategy for assessing the oxidative stress potential of ENMs, which combines acellular methods and fast in vitro screening approaches, as well as a more involved detailed redox proteomics approach. This allows for screening and prioritization in a first tier and, if required, also for unraveling mechanistic details down to compromised signaling pathways. - Highlights: • Oxidative stress is a general paradigm for nanomaterial hazard mechanism of action. • Reactive oxygen species generation can be predicted using acellular assays. • Cellular assays based on fluorescence suffer from interference by nanomaterials. • Protein carbonylation is an irreversible and predictive mark of oxidative stress. • Proteomics of carbonylation indicates affected pathways and mechanism of action.« less

  11. The reliability of in-hospital diagnoses of diabetes mellitus in the setting of an acute myocardial infarction

    PubMed Central

    Arnold, Suzanne V; Lipska, Kasia J; Inzucchi, Silvio E; Li, Yan; Jones, Philip G; McGuire, Darren K; Goyal, Abhinav; Stolker, Joshua M; Lind, Marcus; Spertus, John A; Kosiborod, Mikhail

    2014-01-01

    Objective Incident diabetes mellitus (DM) is important to recognize in patients with acute myocardial infarction (AMI). To develop an efficient screening strategy, we explored the use of random plasma glucose (RPG) at admission and fasting plasma glucose (FPG) to select patients with AMI for glycosylated hemoglobin (HbA1c) testing. Design, setting, andparticipants Prospective registry of 1574 patients with AMI not taking glucose-lowering medication from 24 US hospitals. All patients had HbA1c measured at a core laboratory and admission RPG and ≥2 FPGs recorded during hospitalization. We examined potential combinations of RPG and FPG and compared these with HbA1c≥6.5%—considered the gold standard for DM diagnosis in these analyses. Results An RPG>140 mg/dL or FPG≥126 mg/dL had high sensitivity for DM diagnosis. Combining these into a screening protocol (if admission RPG>140, check HbA1c; or if FPG≥126 on a subsequent day, check HbA1c) led to HbA1c testing in 50% of patients and identified 86% with incident DM (number needed to screen (NNS)=3.3 to identify 1 case of DM; vs NNS=5.6 with universal HbA1c screening). Alternatively, using an RPG>180 led to HbA1c testing in 40% of patients with AMI and identified 82% of DM (NNS=2.7). Conclusions We have established two potential selective screening methods for DM in the setting of AMI that could identify the vast majority of incident DM by targeted screening of 40–50% of patients with AMI with HbA1c testing. Using these methods may efficiently identify patients with AMI with DM so that appropriate education and treatment can be promptly initiated. PMID:25452878

  12. Fourfold increase in prevalence of gestational diabetes mellitus after adoption of the new International Association of Diabetes and Pregnancy Study Groups (IADPSG) criteria.

    PubMed

    Huhn, Evelyn A; Massaro, Nadine; Streckeisen, Simone; Manegold-Brauer, Gwendolin; Schoetzau, Andreas; Schulzke, Sven M; Winzeler, Bettina; Hoesli, Irene; Lapaire, Olav

    2017-04-01

    The aim was to evaluate the influence of the new International Association of Diabetes and Pregnancy Study Groups (IADPSG) guidelines for screening of gestational diabetes mellitus (GDM) on GDM prevalence in a cohort from a Swiss tertiary hospital. This was a retrospective cohort study involving all pregnant women who were screened for GDM between 24 and 28 weeks of gestation. From 2008 until 2010 (period 1), a two-step approach with 1-h 50 g glucose challenge test (GCT) was used, followed by fasting, 1- and 2-h glucose measurements after a 75 g oral glucose tolerance test (OGTT) in case of a positive GCT. From 2010 until 2013 (period 2), all pregnant women were tested with a one-step 75 g OGTT according to new IADPSG guidelines. In both periods, women with risk factors could be screened directly with a 75 g OGTT in early pregnancy. Overall, 647 women were eligible for the study in period 1 and 720 in period 2. The introduction of the IADPSG criteria resulted in an absolute increase of GDM prevalence of 8.5% (3.3% in period 1 to 11.8% in period 2). The adoption of the IADPSG criteria resulted in a considerable increase in GDM diagnosis in our Swiss cohort. Further studies are needed to investigate if the screening is cost effective and if treatment of our additionally diagnosed GDM mothers might improve short-term as well as long-term outcome.

  13. E-FAST-Exposure and Fate Assessment Screening Tool Version 2014

    EPA Pesticide Factsheets

    E-FAST estimates potential exposures to the general population and surface water concentrations based on releases from industrial operations and basic physical-chemical properties and fate parameters of the substance

  14. Effect of Inflammatory and Noninflammatory Stress on Beta-Hydroxybutyrate and Free Fatty Acids in Rat Blood.

    DTIC Science & Technology

    fasting plus screen-restraint and fasting plus femoral fracture. Inflammatory stresses caused a marked inhibition of the normal fasting-induced ketosis ...and a reduction in the level of circulating free fatty acids. Noninflammatory stresses caused no inhibition of the normal fasting-induced ketosis but did cause a reduction in the level of circulating free fatty acids. (Author)

  15. Validity of glycated hemoglobin in screening and diagnosing type 2 diabetes mellitus in Chinese subjects.

    PubMed

    Yu, Yun; Ouyang, Xiao-Jun; Lou, Qing-Lin; Gu, Liu-Bao; Mo, Yong-Zhen; Ko, Gary T; Chow, Chun-Chung; So, Wing-Yee; Ma, Ronald; Kong, Alice; Brown, Nicola; Nan, Jennifer; Chan, Juliana; Bian, Rong-Wen

    2012-03-01

    The application of glycated hemoglobin (HbA(1c)) for the diagnosis of diabetes is currently under extensive discussion. In this study, we explored the validity of using HbA(1c) as a screening and diagnostic test in Chinese subjects recruited in Nanjing, China. In total, 497 subjects (361 men and 136 women) with fasting plasma glucose (PG) ≥ 5.6 mmol/L were recruited to undergo the oral glucose tolerance test (OGTT) and HbA(1c) test. Plasma lipid, uric acid, and blood pressure were also measured. Using a receiver operating characteristic curve, the optimal cutoff point of HbA(1c) related to diabetes diagnosed by the OGTT was 6.3%, with a sensitivity and specificity of 79.6% and 82.2%, respectively, and the area under the curve was 0.87 (95% confidence interval, 0.83 to 0.92). A HbA(1c) level of 6.5% had a sensitivity and specificity of 62.7% and 93.5%, respectively. When comparing the HbA(1c) ≥ 6.5% or OGTT methods for diagnosing diabetes, the former group had significantly higher HbA(1c) levels and lower levels of fasting and 2-hour PG than the latter group. No significant difference was observed in the other metabolism indexes between the two groups. Our results suggest that HbA(1c) ≥ 6.5% has reasonably good specificity for diagnosing diabetes in Chinese subjects, which is in concordance with the American Diabetes Association recommendations.

  16. Combined use of fasting plasma glucose and glycated hemoglobin A1c in the screening of diabetes and impaired glucose tolerance.

    PubMed

    Hu, Yaomin; Liu, Wei; Chen, Yawen; Zhang, Ming; Wang, Lihua; Zhou, Huan; Wu, Peihong; Teng, Xiangyu; Dong, Ying; Zhou, Jia wen; Xu, Hua; Zheng, Jun; Li, Shengxian; Tao, Tao; Hu, Yumei; Jia, Yun

    2010-09-01

    The aim of this study is to assess the validity of combined use of fasting plasma glucose (FPG) and glycated hemoglobin A1c (HbA1c) as screening tests for diabetes and impaired glucose tolerance (IGT) in high-risk subjects. A total of 2,298 subjects were included. All subjects underwent a 75-g oral glucose tolerance test (OGTT) and HbA1c measurement. Receiver operating characteristic curve (ROC curve) analysis was used to examine the sensitivity and specificity of FPG and HbA1c for detecting diabetes and IGT, which was defined according to the 1999 World Health Organization (WHO) criteria. (1) Based on the ROC curve, the optimal cut point of FPG related to diabetes diagnosed by OGTT was 6.1 mmol/l that was associated with a sensitivity and specificity of 81.5 and 81.0%, respectively; The optimal cut point of HbA1c related to diabetes diagnosed by OGTT was 6.1%, which was associated with a sensitivity and specificity of 81.0 and 81.0%, respectively; The screening model using FPG > or = 6.1 mmol/l or HbA1c > or = 6.1% had sensitivity of 96.5% for detecting undiagnosed diabetes; the screening model using FPG > or = 6.1 mmol/l and HbA1c > or = 6.1% had specificity of 96.3% for detecting undiagnosed diabetes. (2) Based on the ROC curve, the optimal cut point of FPG related to IGT diagnosed by OGTT was 5.6 mmol/l that was associated with a sensitivity and specificity of 64.1 and 65.4%, respectively; The optimal cut point of HbA1c related to IGT diagnosed by OGTT was 5.6%, which was associated with a sensitivity and specificity of 66.2 and 51.0%, respectively; The screening model using FPG > or = 5.6 mmol/l or HbA1c > or = 5.6% had sensitivity of 87.9% for detecting undiagnosed IGT; The screening model using FPG > or = 5.6 mmol/l and HbA1c > or = 5.6% had specificity of 82.4% for detecting undiagnosed IGT. Compared with FPG or HbA1c alone, the simultaneous measurement of FPG and HbA1c (FPG and/or HbA1C) might be a more sensitive and specific screening tool for identifying high-risk individuals with diabetes and IGT at an early stage.

  17. [Evaluation on a fast weight reduction model in vitro].

    PubMed

    Li, Songtao; Li, Ying; Wen, Ying; Sun, Changhao

    2010-03-01

    To establish a fast and effective model in vitro for screening weight-reducing drugs and taking preliminary evaluation of the model. Mature adipocytes of SD rat induced by oleic acid were used to establish a obesity model in vitro. Isoprel, genistein, caffeine were selected as positive agents and curcumine as negative agent to evaluate the obesity model. Lipolysis of adipocytes was stimulated significantly by isoprel, genistein and caffeine rather than curcumine. This model could be used efficiently for screening weight-losing drugs.

  18. siMacro: A Fast and Easy Data Processing Tool for Cell-Based Genomewide siRNA Screens.

    PubMed

    Singh, Nitin Kumar; Seo, Bo Yeun; Vidyasagar, Mathukumalli; White, Michael A; Kim, Hyun Seok

    2013-03-01

    Growing numbers of studies employ cell line-based systematic short interfering RNA (siRNA) screens to study gene functions and to identify drug targets. As multiple sources of variations that are unique to siRNA screens exist, there is a growing demand for a computational tool that generates normalized values and standardized scores. However, only a few tools have been available so far with limited usability. Here, we present siMacro, a fast and easy-to-use Microsoft Office Excel-based tool with a graphic user interface, designed to process single-condition or two-condition synthetic screen datasets. siMacro normalizes position and batch effects, censors outlier samples, and calculates Z-scores and robust Z-scores, with a spreadsheet output of >120,000 samples in under 1 minute.

  19. siMacro: A Fast and Easy Data Processing Tool for Cell-Based Genomewide siRNA Screens

    PubMed Central

    Singh, Nitin Kumar; Seo, Bo Yeun; Vidyasagar, Mathukumalli; White, Michael A.

    2013-01-01

    Growing numbers of studies employ cell line-based systematic short interfering RNA (siRNA) screens to study gene functions and to identify drug targets. As multiple sources of variations that are unique to siRNA screens exist, there is a growing demand for a computational tool that generates normalized values and standardized scores. However, only a few tools have been available so far with limited usability. Here, we present siMacro, a fast and easy-to-use Microsoft Office Excel-based tool with a graphic user interface, designed to process single-condition or two-condition synthetic screen datasets. siMacro normalizes position and batch effects, censors outlier samples, and calculates Z-scores and robust Z-scores, with a spreadsheet output of >120,000 samples in under 1 minute. PMID:23613684

  20. Significance of HbA1c and its measurement in the diagnosis of diabetes mellitus: US experience.

    PubMed

    Juarez, Deborah Taira; Demaris, Kendra M; Goo, Roy; Mnatzaganian, Christina Louise; Wong Smith, Helen

    2014-01-01

    The 2014 American Diabetes Association guidelines denote four means of diagnosing diabetes. The first of these is a glycosylated hemoglobin (HbA1c) >6.5%. This literature review summarizes studies (n=47) in the USA examining the significance, strengths, and limitations of using HbA1c as a diagnostic tool for diabetes, relative to other available means. Due to the relatively recent adoption of HbA1c as a diabetes mellitus diagnostic tool, a hybrid systematic, truncated review of the literature was implemented. Based on these studies, we conclude that HbA1c screening for diabetes has been found to be convenient and effective in diagnosing diabetes. HbA1c screening is particularly helpful in community-based and acute care settings where tests requiring fasting are not practical. Using HbA1c to diagnose diabetes also has some limitations. For instance, HbA1c testing may underestimate the prevalence of diabetes, particularly among whites. Because this bias differs by racial group, prevalence and resulting estimates of health disparities based on HbA1c screening differ from those based on other methods of diagnosis. In addition, existing evidence suggests that HbA1c screening may not be valid in certain subgroups, such as children, women with gestational diabetes, patients with human immunodeficiency virus, and those with prediabetes. Further guidelines are needed to clarify the appropriate use of HbA1c screening in these populations.

  1. Fast energy spectrum and transverse beam profile monitoring and feedback systems for the SLC linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soderstrom, E.J.; Abrams, G.S.; Weinstein, A.J.

    Fast energy spectrum and transverse beam profile monitoring systems have been tested at the SLC. The signals for each system are derived from digitizations of images on phosphor screens. Individual beam bunch images are digitized in the case of the transverse profile system and synchrotron radiation images produced by wiggler magnets for the energy spectrum. Measurements are taken at two-second intervals. Feedback elements have been installed for future use and consist of rf phase shifters to control energy spectrum and dipole correctors to control the beam launch into the linac affecting the transverse beam profile. Details of these systems, includingmore » hardware, timing, data acquisition, data reduction, measurement accuracy, and operational experience will be presented. 9 refs.« less

  2. The importance of sensitive screening for abnormal glucose metabolism in patients with IgA nephropathy.

    PubMed

    Jia, Xiaoyuan; Pan, Xiaoxia; Xie, Jingyuan; Shen, Pingyan; Wang, Zhaohui; Li, Ya; Wang, Weiming; Chen, Nan

    2016-01-01

    To investigate the prevalence of abnormal glucose metabolism, insulin resistance (IR) and the related risk factors in IgA nephropathy (IgAN) patients. We analyzed oral glucose tolerance test (OGTT) and clinical data of 107 IgAN patients and 106 healthy controls. Glucose metabolism, homeostasis model assessment of insulin resistance (HOMA-IR) and the insulin sensitivity index (ISI) of both groups were evaluated. The prevalence of abnormal glucose metabolism was significantly higher in the IgAN group than in the control group (41.12% vs. 9.43%, p < 0.001), while the prevalence of IR between the two groups was not significantly different. IgAN patients have significantly higher fasting blood glucose, fasting insulin, OGTT 2-hour blood glucose, OGTT 2-hour insulin, HOMA-IR, and lower ISI than healthy controls. Triglyceride (OR = 2.55), 24-hour urine protein excretion (OR = 1.39), and age (OR = 1.06) were independent risk factors for abnormal glucose metabolism in IgAN patients. BMI, eGFR, 24-hour urine protein excretion, triglyceride, fasting blood glucose, fasting insulin, OGTT 2-hour blood glucose, and OGTT 2-hour insulin were significantly higher in IgAN patients with IR than in IgAN patients without IR, while HDL and ISI were significantly lower. BMI, serum albumin, and 24-hour urine protein excretion were correlated factors of IR in IgAN patients. Our study highlighted that abnormal glucose metabolism was common in IgAN patients. Triglyceride and 24-hour urine protein excretion were significant risk factors for abnormal glucose metabolism. Therefore, sensitive screening for glucose metabolism status and timely intervention should be carried out in clinical work.

  3. Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration.

    PubMed

    Meyer, Golo M J; Weber, Armin A; Maurer, Hans H

    2014-05-01

    Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.

  4. A comparative study of first-derivative spectrophotometry and column high-performance liquid chromatography applied to the determination of repaglinide in tablets and for dissolution testing.

    PubMed

    AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser

    2008-01-01

    A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.

  5. The Novel Language-Systematic Aphasia Screening SAPS: Screening-Based Therapy in Combination with Computerised Home Training

    ERIC Educational Resources Information Center

    Krzok, Franziska; Rieger, Verena; Niemann, Katharina; Nobis-Bosch, Ruth; Radermacher, Irmgard; Huber, Walter; Willmes, Klaus; Abel, Stefanie

    2018-01-01

    Background: SAPS--'Sprachsystematisches Aphasiescreening'--is a novel language-systematic aphasia screening developed for the German language, which already had been positively evaluated. It offers a fast assessment of modality-specific psycholinguistic components at different levels of complexity and the derivation of impairment-based treatment…

  6. Barriers to postpartum screening for type 2 diabetes: a qualitative study of women with previous gestational diabetes

    PubMed Central

    Rafii, Forough; Rahimparvar, Seyedeh Fatemeh Vasegh; Mehrdad, Neda; Keramat, Afsaneh

    2017-01-01

    Introduction Risk of developing type 2 diabetes is increased in women with previous gestational diabetes mellitus (GDM). Postpartum glycemic screening is recommended in women with recent GDM. But this screening rate is low and the reasons are unclear. The aim of this study was to explore the experiences of Iranian women with recent GDM on barriers of postpartum screening for diabetes. Methods This qualitative study was conducted in Tehran, Iran in 2016. Semi-structured interview was used for data collection. 22 women with recent GDM were interviewed. These women gave birth in Tehran hospitals at a minimum of 6 months before interview. The missed screening defined as not attending to laboratory for Fasting Blood Sugar and/or Oral Glucose Tolerance Test, 6 week to 6 month after their child birthing. The data was analyzed by content analysis method. Results Themes and sub-themes that illustrated the barriers to postpartum diabetes screening were: inadequate education (about developing diabetes in the future, implementation of the screening, and glucometer validity in diagnosis of diabetes), perceiving the screening as difficult (feeling comfortable with the glucometer, poor laboratory conditions, issues related to the baby/babies, and financial problems), improper attitudes toward the screening (unwilling to get diagnosed, not giving priority to oneself, having false beliefs) and procrastination (gap to intention and action, self-deception and self-regulation failure). Conclusion Women with recent GDM reported several barriers for postpartum diabetes screening. This study help to develop the evidence-based interventions for improving this screening rate. PMID:28451031

  7. Associations between Markers of Glucose and Insulin Function and Cognitive Function in Healthy African American Elders

    PubMed Central

    Skinner, Jeannine S.; Morgan, Amy; Hernandez-Saucedo, Hector; Hansen, Angela; Corbett, Selena; Arbuckle, Matthew; Leverenz, James BA; Wilkins, Consuelo H.; Craft, Suzanne; Baker, Laura D.

    2015-01-01

    Background Glucose and insulin are important moderators of cognitive function. African Americans have poorer glycemic control across the glycemic spectrum and are at increased risk for type 2 diabetes and poor cognitive health. It is unclear which glucoregulatory markers predict cognitive function in this at-risk population. The purpose of this study was to examine the association between cognitive function and common markers of glucoregulation in non-diabetic African Americans elders. Methods Thirty-four, community-dwelling African Americans, aged 50-75 years completed cognitive testing and blood collection as part of a health screening assessment. Cognitive outcomes were composite scores derived from neuropsychological tests of executive function and verbal memory. Linear regression was used to examine relationships between cognitive composite scores and fasting blood levels of glucose, insulin, and hemoglobin A1C, with adjustments for age, education, body mass index, and antihypertensive medication use. Results Fasting plasma glucose was negatively associated with executive function (β=−0.41, p=0.03). There was a trend of an association between fasting plasma glucose and verbal memory (β=−0.34, p=0.06). Fasting insulin and hemoglobin A1c were not associated with cognitive function. Conclusion High non-diabetic fasting glucose levels were associated with poorer executive function and verbal memory. These results provide preliminary support for proactive glucose control in older African Americans even before glycemic criteria for type 2 diabetes are met. Our findings suggests that high-normal FPG levels may represent an early red-flag to signify increased risk of cognitive impairment or decline. PMID:26798567

  8. A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urbain, X., E-mail: xavier.urbain@uclouvain.be; Bech, D.; Van Roy, J.-P.

    A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atomsmore » are presented, which illustrate the performances of the COBRA detection scheme.« less

  9. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

    PubMed

    Day, John D; Doshi, Rahul N; Belott, Peter; Birgersdotter-Green, Ulrika; Behboodikhah, Mahnaz; Ott, Peter; Glatter, Kathryn A; Tobias, Serge; Frumin, Howard; Lee, Byron K; Merillat, John; Wiener, Isaac; Wang, Samuel; Grogin, Harlan; Chun, Sung; Patrawalla, Rob; Crandall, Brian; Osborn, Jeffrey S; Weiss, J Peter; Lappe, Donald L; Neuman, Stacey

    2007-05-08

    Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations) is the first large, multicenter, prospective trial comparing vulnerability safety margin testing versus defibrillation safety margin testing with a single VF induction/defibrillation. A total of 426 patients receiving an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator underwent vulnerability safety margin or defibrillation safety margin screening at 14 J in a randomized order. After this, patients underwent confirmatory testing, which required 2 VF conversions without failure at < or = 21 J. Patients who passed their first 14-J and confirmatory tests, irrespective of the results of their second 14-J test, had their devices programmed to a 21-J shock for ventricular tachycardia (VT) or VF > or = 200 bpm and were followed up for 1 year. Of 420 patients who underwent 14-J vulnerability safety margin screening, 322 (76.7%) passed. Of these, 317 (98.4%) also passed 21-J confirmatory tests. Of 416 patients who underwent 14-J defibrillation safety margin screening, 343 (82.5%) passed, and 338 (98.5%) also passed 21-J confirmatory tests. Most clinical VT/VF episodes (32 of 37, or 86%) were terminated by the first shock, with no difference in first shock success. In all observed cases in which the first shock was unsuccessful, subsequent shocks terminated VT/VF without complication. Although spontaneous episodes of fast VT/VF were limited, there was no difference in the odds of first shock efficacy between groups. Screening with vulnerability safety margin or defibrillation safety margin may allow for inductionless or limited shock testing in most patients.

  10. Receptor-based screening assays for the detection of antibiotics residues - A review.

    PubMed

    Ahmed, Saeed; Ning, Jianan; Cheng, Guyue; Ahmad, Ijaz; Li, Jun; Mingyue, Liu; Qu, Wei; Iqbal, Mujahid; Shabbir, M A B; Yuan, Zonghui

    2017-05-01

    Consumer and regulatory agencies have a high concern to antibiotic residues in food producing animals, so appropriate screening assays of fast, sensitive, low cost, and easy sample preparation for the identification of these residues are essential for the food-safety insurance. Great efforts in the development of a high-throughput antibiotic screening assay have been made in recent years. Concerning the screening of antibiotic residue, this review elaborate an overview on the availability, advancement and applicability of antibiotic receptor based screening assays for the safety assessment of antibiotics usage (i.e. radio receptor assay, enzyme labeling assays, colloidal gold receptor assay, enzyme colorimetry assay and biosensor assay). This manuscript also tries to shed a light on the selection, preparation and future perspective of receptor protein for antibiotic residue detection. These assays have been introduced for the screening of numerous food samples. Receptor based screening technology for antibiotic detection has high accuracy. It has been concluded that at the same time, it can detect a class of drugs for certain receptor, and realize the multi-residue detection. These assays offer fast, easy and precise detection of antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Value of EZSCAN parameters for diabetes screening in Chinese.

    PubMed

    Lin, Yanhui; Chen, Zhiheng; Guo, Xu; Deng, Yulin

    2017-05-23

    To study the parameters of EZSCAN as a screening tool for diabetes in Chinese. A total of 6,270 subjects participated in the study. All subjects underwent tests of EZSCAN, fasting plasma glucose (FPG), oral glucose tolerance test and HbA 1c . 1. All subjects were divided into 4 groups: the normal group, sugar metabolic abnormalities as low-risk group, middle-risk group and high-risk group. The difference of diabetes incidence among the 4 groups was statistically significant. With the increase of EZSCAN score, the prevalence of diabetes increased significantly. But there is no statistically difference between the low-risk group and the middle-risk group. 2. After adjustment for other variables, there is significantly positive relationship among EZSCAN risk score and the risk of diabetes. Meanwhile there is no statistically difference between the low-risk group and the middle-risk group. 3. The cut-off point of EZSCAN for diabetes was 44.5% with the sensitivity was 73.2% which was higher than of FPG and HbA 1c . As EZSCAN-diabetes risk score increases, the risk of diabetes increases. EZSCAN can be used as a tool for screening for diabetes. At the best screening diabetes cut-off point value 44.5%, the sensitivity is higher than traditional method of FPG and HbA 1c . Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  12. Prevention, Detection, and Management of Diabetes in South Dakota.

    PubMed

    Hogue, Amy L; Huntington, Mark K

    2017-01-01

    Diabetes mellitus (DM) is increasing in prevalence nationwide and in South Dakota, with an especially high prevalence in its American Indian population. Screening is not recommended for type 1 DM, but is for type 2 DM and pre-diabetes in certain populations. Fasting glucose, two-hour glucose tolerance test, or hemoglobin A1c are appropriate screening options. Treatment can include diabetic self-management education programs and medications. In addition to glycemic control, other cardiovascular risk factors must be reduced in these patients and specific testing and consultations should be performed to detect complications such as nephropathy or retinopathy. Along with routine age-appropriate immunizations, most diabetic patients should receive the pneumococcal polysaccharide vaccine (PPSV-23), influenza, and the hepatitis B series. Progression from pre-diabetes to type 2 DM can be prevented or delayed in some patients through lifestyle interventions and/or metformin. The South Dakota Diabetes Coalition (www.sddiabetescoalition.org) is an excellent resource for clinicians and patients. Copyright© South Dakota State Medical Association.

  13. Screening, monitoring, and educating patients with diabetes in an independent community pharmacy in Puerto Rico.

    PubMed

    Jiménez, F J; Monsanto, H A

    2001-03-01

    Increase the awareness about the importance of Diabetes mellitus (DM) management and assess the educational and monitoring needs of patients visiting a community pharmacy in Puerto Rico. A community service activity focusing on DM was held in a community pharmacy. The educational and monitoring needs of the participants were assessed using a questionnaire. Glucose tests were conducted in the pharmacy by medical technologists. Educational activities consisted of presentations and printed materials. Two-thirds of the fasting people had blood glucose levels higher than 140 mg/dl. Seventy-nine percent of the patients with diabetes were not aware of the glycosilated hemoglobin test. Most of the patients were interested in learning more about how to manage their condition. A greater understanding is needed among patients with DM that blood glucose control decreases diabetes related complications. Community pharmacists are in an excellent position to collaborate with other health professionals in screening, monitoring and educating patients with DM to prevent long-term complications.

  14. Nano-Sized Natural Colorants from Rocks and Soils

    NASA Astrophysics Data System (ADS)

    Ahmad, W. Y. W.; Ruznan, W. S.; Hamid, H. A.; Kadir, M. I. A.; Yusoh, M. K. M.; Ahmad, M. R.

    2010-03-01

    Colored rocks (lateritic) and soils (shales) are available in abundant all around Malaysia and they are from natural sources. The colorants will be useful if they can be transferred to substrates using dyeing, printing or brushing with acceptable fastness. First of all the rocks need to be crushed into powder form before coloration can take place. The sizes of the colorants particles obtained with coffee grinder were of 7-8 microns. They can be reduced to 3-5 micron using fluidized bed jetmill and to nano sizes with the help of planetary mono mill grinders. The experiment was conducted in both dyeing and printing of textiles using all three sizes (7-8 microns, 3-5 microns and nano sizes) of colorants on silk fabric. The colorants were applied on silk fabrics by dyeing and tie and dye techniques. In addition, the colorants can also be applied by brushing technique as in batik canting or batik block as well as silk screen printing. The evaluations of colored materials were based on the levelness of dyeing, fastness properties (washing, light and rubbing fastness) and color strength. The wash fastness testing shows that all colorants sizes have more or less the same fastness to washing but nano sized colorants produced better uniform dyes distribution (levelness of dyeing) and higher color strength.

  15. Relating Memory To Functional Performance In Normal Aging to Dementia Using Hierarchical Bayesian Cognitive Processing Models

    PubMed Central

    Shankle, William R.; Pooley, James P.; Steyvers, Mark; Hara, Junko; Mangrola, Tushar; Reisberg, Barry; Lee, Michael D.

    2012-01-01

    Determining how cognition affects functional abilities is important in Alzheimer’s disease and related disorders (ADRD). 280 patients (normal or ADRD) received a total of 1,514 assessments using the Functional Assessment Staging Test (FAST) procedure and the MCI Screen (MCIS). A hierarchical Bayesian cognitive processing (HBCP) model was created by embedding a signal detection theory (SDT) model of the MCIS delayed recognition memory task into a hierarchical Bayesian framework. The SDT model used latent parameters of discriminability (memory process) and response bias (executive function) to predict, simultaneously, recognition memory performance for each patient and each FAST severity group. The observed recognition memory data did not distinguish the six FAST severity stages, but the latent parameters completely separated them. The latent parameters were also used successfully to transform the ordinal FAST measure into a continuous measure reflecting the underlying continuum of functional severity. HBCP models applied to recognition memory data from clinical practice settings accurately translated a latent measure of cognition to a continuous measure of functional severity for both individuals and FAST groups. Such a translation links two levels of brain information processing, and may enable more accurate correlations with other levels, such as those characterized by biomarkers. PMID:22407225

  16. Rationale in diagnosis and screening of atrophic gastritis with stomach-specific plasma biomarkers

    PubMed Central

    Agréus, Lars; Kuipers, Ernst J; Kupcinskas, Limas; Malfertheiner, Peter; Di Mario, Francesco; Leja, Marcis; Mahachai, Varocha; Yaron, Niv; Van Oijen, Martijn; Perez, Guillermo Perez; Rugge, Massimo; Ronkainen, Jukka; Salaspuro, Mikko; Sipponen, Pentti; Sugano, Kentaro; Sung, Joseph

    2012-01-01

    Background and aims Atrophic gastritis (AG) results most often from Helicobacter pylori (H. pylori) infection. AG is the most important single risk condition for gastric cancer that often leads to an acid-free or hypochlorhydric stomach. In the present paper, we suggest a rationale for noninvasive screening of AG with stomach-specific biomarkers. Methods The paper summarizes a set of data on application of the biomarkers and describes how the test results could be interpreted in practice. Results In AG of the gastric corpus and fundus, the plasma levels of pepsinogen I and/or the pepsinogen I/pepsinogen II ratio are always low. The fasting level of gastrin-17 is high in AG limited to the corpus and fundus, but low or non-elevated if the AG occurs in both antrum and corpus. A low fasting level of G-17 is a sign of antral AG or indicates high intragastric acidity. Differentiation between antral AG and high intragastric acidity can be done by assaying the plasma G-17 before and after protein stimulation, or before and after administration of the proton pump inhibitors (PPI). Amidated G-17 will rise if the antral mucosa is normal in structure. H. pylori antibodies are a reliable indicator of helicobacter infection, even in patients with AG and hypochlorhydria. Conclusions Stomach-specific biomarkers provide information about the stomach health and about the function of stomach mucosa and are a noninvasive tool for diagnosis and screening of AG and acid-free stomach. PMID:22242613

  17. Tools for the diagnosis of hepatitis C virus infection and hepatic fibrosis staging

    PubMed Central

    Saludes, Verónica; González, Victoria; Planas, Ramon; Matas, Lurdes; Ausina, Vicente; Martró, Elisa

    2014-01-01

    Hepatitis C virus (HCV) infection represents a major public health issue. Hepatitis C can be cured by therapy, but many infected individuals are unaware of their status. Effective HCV screening, fast diagnosis and characterization, and hepatic fibrosis staging are highly relevant for controlling transmission, treating infected patients and, consequently, avoiding end-stage liver disease. Exposure to HCV can be determined with high sensitivity and specificity with currently available third generation serology assays. Additionally, the use of point-of-care tests can increase HCV screening opportunities. However, active HCV infection must be confirmed by direct diagnosis methods. Additionally, HCV genotyping is required prior to starting any treatment. Increasingly, high-volume clinical laboratories use different types of automated platforms, which have simplified sample processing, reduced hands-on-time, minimized contamination risks and human error and ensured full traceability of results. Significant advances have also been made in the field of fibrosis stage assessment with the development of non-invasive methods, such as imaging techniques and serum-based tests. However, no single test is currently available that is able to completely replace liver biopsy. This review focuses on approved commercial tools used to diagnose HCV infection and the recommended hepatic fibrosis staging tests. PMID:24707126

  18. DNA-conjugated gold nanoparticles based colorimetric assay to assess helicase activity: a novel route to screen potential helicase inhibitors

    NASA Astrophysics Data System (ADS)

    Deka, Jashmini; Mojumdar, Aditya; Parisse, Pietro; Onesti, Silvia; Casalis, Loredana

    2017-03-01

    Helicase are essential enzymes which are widespread in all life-forms. Due to their central role in nucleic acid metabolism, they are emerging as important targets for anti-viral, antibacterial and anti-cancer drugs. The development of easy, cheap, fast and robust biochemical assays to measure helicase activity, overcoming the limitations of the current methods, is a pre-requisite for the discovery of helicase inhibitors through high-throughput screenings. We have developed a method which exploits the optical properties of DNA-conjugated gold nanoparticles (AuNP) and meets the required criteria. The method was tested with the catalytic domain of the human RecQ4 helicase and compared with a conventional FRET-based assay. The AuNP-based assay produced similar results but is simpler, more robust and cheaper than FRET. Therefore, our nanotechnology-based platform shows the potential to provide a useful alternative to the existing conventional methods for following helicase activity and to screen small-molecule libraries as potential helicase inhibitors.

  19. Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds.

    PubMed

    de-Souza-Silva, Calliandra Maria; Guilhelmelli, Fernanda; Zamith-Miranda, Daniel; de Oliveira, Marco Antônio; Nosanchuk, Joshua Daniel; Silva-Pereira, Ildinete; Albuquerque, Patrícia

    2018-02-14

    Fungal infections have become an important medical condition in the last decades, but the number of available antifungal drugs is limited. In this scenario, the search for new antifungal drugs is necessary. The protocol reported here details a method to screen peptides for their antifungal properties. It is based on the broth microdilution susceptibility test from the Clinical and Laboratory Standards Institute (CLSI) M27-A3 guidelines with modifications to suit the research of antimicrobial peptides as potential new antifungals. This protocol describes a functional assay to evaluate the activity of antifungal compounds and may be easily modified to suit any particular class of molecules under investigation. Since the assays are performed in 96-well plates using small volumes, a large-scale screening can be completed in a short amount of time, especially if carried out in an automation setting. This procedure illustrates how a standardized and adjustable clinical protocol can help the bench-work pursuit of new molecules to improve the therapy of fungal diseases.

  20. Stripline fast faraday cup for measuring GHz structure of ion beams

    DOEpatents

    Bogaty, John M.

    1992-01-01

    The Stripline Fast Faraday Cup is a device which is used to quantitatively and qualitatively measure gigahertz time structure characteristics of ion beams with energies up to at least 30 Mev per nucleon. A stripline geometry is employed in conjunction with an electrostatic screen and a Faraday cup to provide for analysis of the structural characteristics of an ion beam. The stripline geometry allows for a large reduction in the size of the instrument while the electrostatic screen permits measurements of the properties associated with low speed ion beams.

  1. Prevalence of gestational diabetes mellitus based on various screening strategies in western Kenya: a prospective comparison of point of care diagnostic methods.

    PubMed

    Pastakia, Sonak D; Njuguna, Benson; Onyango, Beryl Ajwang'; Washington, Sierra; Christoffersen-Deb, Astrid; Kosgei, Wycliffe K; Saravanan, Ponnusamy

    2017-07-14

    Early diagnosis of gestational diabetes mellitus (GDM) is crucial to prevent short term delivery risks and long term effects such as cardiovascular and metabolic diseases in the mother and infant. Diagnosing GDM in Sub-Saharan Africa (SSA) however, remains sub-optimal due to associated logistical and cost barriers for resource-constrained populations. A cost-effective strategy to screen for GDM in such settings are therefore urgently required. We conducted this study to determine the prevalence of gestational diabetes mellitus (GDM) and assess utility of various GDM point of care (POC) screening strategies in a resource-constrained setting. Eligible women aged ≥18 years, and between 24 and 32 weeks of a singleton pregnancy, prospectively underwent testing over two days. On day 1, a POC 1-h 50 g glucose challenge test (GCT) and a POC glycated hemoglobin (HbA1c) was assessed. On day 2, fasting blood glucose, 1-h and 2-h 75 g oral glucose tolerance test (OGTT) were determined using both venous and POC tests, along with a venous HbA1c. The International Association of Diabetes in Pregnancy Study Group (IADPSG) criteria was used to diagnose GDM. GDM prevalence was reported with 95% confidence interval (CI). Specificity, sensitivity, positive predictive value, and negative predictive value of the various POC testing strategies were determined using IADPSG testing as the standard reference. Six hundred-sixteen eligible women completed testing procedures. GDM was diagnosed in 18 women, a prevalence of 2.9% (95% CI, 1.57% - 4.23%). Compared to IADPSG testing, POC IADPSG had a sensitivity and specificity of 55.6% and 90.6% respectively while that of POC 1-h 50 g GCT (using a diagnostic cut-off of ≥7.2 mmol/L [129.6 mg/dL]) was 55.6% and 63.9%. All other POC tests assessed showed poor sensitivity. POC screening strategies though feasible, showed poor sensitivity for GDM detection in our resource-constrained population of low GDM prevalence. Studies to identify sensitive and specific POC GDM screening strategies using adverse pregnancy outcomes as end points are required. Clinical trials.gov : NCT02978807 , Registered 29 November 2016.

  2. [HTRF-based high-throughput PGE2 release prohibition model and application in discovering traditional Chinese medicine active ingredients].

    PubMed

    Bai, Zhi-Ru; Fei, Hong-Qiang; Li, Na; Cao, Liang; Zhang, Chen-Feng; Wang, Tuan-Jie; Ding, Gang; Wang, Zhen-Zhong; Xiao, Wei

    2016-02-01

    Prostaglandin (PG) E2 is an active substance in pathological and physiological mechanisms, such as inflammation and pain. The in vitro high-throughput assay for screening the inhibitors of reducing PEG2 production is a useful method for finding out antiphlogistic and analgesic candidates. The assay was based on LPS-induced PGE2 production model using a homogeneous time-resolved fluorescence(HTRF) PGE2 testing kit combined with liquid handling automation and detection instruments. The critical steps, including the cell density optimization and IC50 values determination of a positive compound, were taken to verify the stability and sensibility of the assay. Low intra-plate, inter-plate and day-to-day variability were observed in this 384-well, high-throughput format assay. Totally 5 121 samples were selected from the company's traditional Chinese medicine(TCM) material base library and used to screen PGE2 inhibitors. In this model, the cell plating density was 2 000 cells for each well; the average IC₅₀ value for positive compounds was (7.3±0.1) μmol; the Z' factor for test plates was more than 0.5 and averaged at 0.7. Among the 5 121 samples, 228 components exhibited a PGE2 production prohibition rate of more than 50%, and 23 components exhibited more than 80%. This model reached the expected standards in data stability and accuracy, indicating the reliability and authenticity of the screening results. The automated screening system was introduced to make the model fast and efficient, with a average daily screening amount exceeding 14 000 data points and provide a new model for discovering new anti-inflammatory and analgesic drug and quickly screening effective constituents of TCM in the early stage. Copyright© by the Chinese Pharmaceutical Association.

  3. Optimal Cut-Off Points of Fasting Plasma Glucose for Two-Step Strategy in Estimating Prevalence and Screening Undiagnosed Diabetes and Pre-Diabetes in Harbin, China

    PubMed Central

    Sun, Bo; Lan, Li; Cui, Wenxiu; Xu, Guohua; Sui, Conglan; Wang, Yibaina; Zhao, Yashuang; Wang, Jian; Li, Hongyuan

    2015-01-01

    To identify optimal cut-off points of fasting plasma glucose (FPG) for two-step strategy in screening abnormal glucose metabolism and estimating prevalence in general Chinese population. A population-based cross-sectional study was conducted on 7913 people aged 20 to 74 years in Harbin. Diabetes and pre-diabetes were determined by fasting and 2 hour post-load glucose from the oral glucose tolerance test in all participants. Screening potential of FPG, cost per case identified by two-step strategy, and optimal FPG cut-off points were described. The prevalence of diabetes was 12.7%, of which 65.2% was undiagnosed. Twelve percent or 9.0% of participants were diagnosed with pre-diabetes using 2003 ADA criteria or 1999 WHO criteria, respectively. The optimal FPG cut-off points for two-step strategy were 5.6 mmol/l for previously undiagnosed diabetes (area under the receiver-operating characteristic curve of FPG 0.93; sensitivity 82.0%; cost per case identified by two-step strategy ¥261), 5.3 mmol/l for both diabetes and pre-diabetes or pre-diabetes alone using 2003 ADA criteria (0.89 or 0.85; 72.4% or 62.9%; ¥110 or ¥258), 5.0 mmol/l for pre-diabetes using 1999 WHO criteria (0.78; 66.8%; ¥399), and 4.9 mmol/l for IGT alone (0.74; 62.2%; ¥502). Using the two-step strategy, the underestimates of prevalence reduced to nearly 38% for pre-diabetes or 18.7% for undiagnosed diabetes, respectively. Approximately a quarter of the general population in Harbin was in hyperglycemic condition. Using optimal FPG cut-off points for two-step strategy in Chinese population may be more effective and less costly for reducing the missed diagnosis of hyperglycemic condition. PMID:25785585

  4. Adolescent male hazardous drinking and participation in organised activities: involvement in team sports is associated with less hazardous drinking in young offenders.

    PubMed

    Hallingberg, Britt; Moore, Simon; Morgan, Joanne; Bowen, Katharine; van Goozen, Stephanie H M

    2015-02-01

    There is a lack of research investigating organised activity participation and associated alcohol use in vulnerable groups. The purpose of this research was to test and compare associations between participation in organised activities and indicators of hazardous drinking between young offenders and young non-offenders. Two groups of 13-18 year-old males were recruited in Cardiff, UK: 93 young offenders and 53 non-offenders from secondary schools matched on estimated IQ, sex and socioeconomic status. Indicators of hazardous drinking were measured using the Fast Alcohol Screening Test (FAST). Organised activity participation and externalising behaviour was measured by the Youth Self Report. The Wechsler Abbreviated Scale of Intelligence was also administered. Young offenders participated in fewer organised activities and had higher FAST scores than non-offenders. Young offenders and non-offenders significantly differed on mean FAST scores if they participated in no organised activities but not if they participated in at least one team sport. Externalising behaviour problems were unrelated to participation in organised activities. Although young offenders were less likely to have participated in organised activities, for them, participation in a team sport was associated with less hazardous drinking. Vulnerable youths who might benefit most from sporting activities actually access them the least. Future research should identify the different barriers to participation that they face. © 2014 The Authors. Criminal Behaviour and Mental Health published by John Wiley & Sons, Ltd.

  5. Development and validation of a streamlined method designed to detect residues of 62 veterinary drugs in bovine kidney using ultra-high performance liquid chromatography--tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R; Geis-Asteggiante, Lucía; Schneider, Marilyn J; Dutko, Terry; Ng, Chilton; Bluhm, Louis; Mastovska, Katerina

    2012-08-01

    In the USA, the US Department of Agriculture's Food Safety and Inspection Service (FSIS) conducts the National Residue Program designed to monitor veterinary drug and other chemical residues in beef and other slaughtered food animals. Currently, FSIS uses a 7-plate bioassay in the laboratory to screen for antimicrobial drugs in bovine kidneys from those animals tested positive by inspectors in the slaughter establishments. The microbial inhibition bioassay has several limitations in terms of monitoring scope, sensitivity, selectivity, and analysis time. Ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) has many advantages over the bioassay for this application, and this study was designed to develop, evaluate, and validate a fast UHPLC-MS/MS method for antibiotics and other high-priority veterinary drugs in bovine kidney. Five existing multi-class, multi-residue methods from the literature were tested and compared, and each performed similarly. Experiments with incurred samples demonstrated that a 5-min shake of 2 g homogenized kidney with 10 ml of 4/1 (v/v) acetonitrile/water followed by simultaneous clean-up of the initial extract with 0.5 g C18 and 10 ml hexane gave a fast, simple, and effective sample preparation method for the <10 min UHPLC-MS/MS analysis. An extensive 5-day validation process demonstrated that the final method could be used to acceptably screen for 54 of the 62 drugs tested, and 50 of those met qualitative MS identification criteria. Quantification was not needed in the application, but the method gave ≥ 70% recoveries and ≤ 25% reproducibilities for 30 of the drugs. Published 2012. This article is a U.S. Government work and is in the public domain of the USA.

  6. Use of HbA(1C) testing to diagnose pre-diabetes in high risk African American children: a comparison with fasting glucose and HOMA-IR.

    PubMed

    Sharma, Sushma; Fleming, Sharon E

    2012-01-01

    This study aimed to compare the discriminating power of HbA(1C) with other pre-diabetes diagnostic tests specifically in high-risk African American children. A cross-sectional analysis was performed on a sample of 172 children (70 boys and 102 girls) aged 9-11 years with BMI's above the 85th percentile. Fasting glucose, insulin and HbA(1C) were analyzed from the plasma samples. Of the 172 participants included in this analysis, 21 (12.2%) had HbA(1C) concentrations above the cutoff of 5.7 used to identify pre-diabetes. None (0%) of these 21 participants, however, were observed to have a glucose concentration above the pre-diabetes cutoff of 110 mg/dl, and only 13 of 21 participants had HOMA-IR above the pre-diabetes cutoff of 2.5. When compared to the previously identified glucose cutoff of 110 mg/dl and HOMA-IR cutoff of 2.5 for pre-diabetes, HbA(1C) showed high specificity (88 and 93%, respectively) but very low sensitivity (0 and 21%, respectively). Glucose, insulin and HOMA-IR were significantly interrelated, but HbA(1C) was not significantly correlated with these biochemical prediabetes assessment variables, nor with anthropometric (BMIz, WC) risk factors. Our results suggest that HbA(1C) had poor discrimination power to identify prediabetes in overweight and obese 9- to 11-year-old African American children. Future studies are recommended to compare the feasibility, sensitivity and predictive power of different screening tests currently recommended to avoid inadequacy when screening for prediabetes and diabetes. Copyright © 2012 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  7. Screening for type 2 diabetes and population mortality over 10 years (ADDITION-Cambridge): a cluster-randomised controlled trial.

    PubMed

    Simmons, Rebecca K; Echouffo-Tcheugui, Justin B; Sharp, Stephen J; Sargeant, Lincoln A; Williams, Kate M; Prevost, A Toby; Kinmonth, Ann Louise; Wareham, Nicholas J; Griffin, Simon J

    2012-11-17

    The increasing prevalence of type 2 diabetes poses a major public health challenge. Population-based screening and early treatment for type 2 diabetes could reduce this growing burden. However, uncertainty persists around the benefits of screening for type 2 diabetes. We assessed the effect of a population-based stepwise screening programme on mortality. In a pragmatic parallel group, cluster-randomised trial, 33 general practices in eastern England were randomly assigned by the method of minimisation in an unbalanced design to: screening followed by intensive multifactorial treatment for people diagnosed with diabetes (n=15); screening plus routine care of diabetes according to national guidelines (n=13); and a no-screening control group (n=5). The study population consisted of 20,184 individuals aged 40-69 years (mean 58 years), at high risk of prevalent undiagnosed diabetes, on the basis of a previously validated risk score. In screening practices, individuals were invited to a stepwise programme including random capillary blood glucose and glycated haemoglobin (HbA(1c)) tests, a fasting capillary blood glucose test, and a confirmatory oral glucose tolerance test. The primary outcome was all-cause mortality. All participants were flagged for mortality surveillance by the England and Wales Office of National Statistics. Analysis was by intention-to-screen and compared all-cause mortality rates between screening and control groups. This study is registered, number ISRCTN86769081. Of 16,047 high-risk individuals in screening practices, 15,089 (94%) were invited for screening during 2001-06, 11,737 (73%) attended, and 466 (3%) were diagnosed with diabetes. 4137 control individuals were followed up. During 184,057 person-years of follow up (median duration 9·6 years [IQR 8·9-9·9]), there were 1532 deaths in the screening practices and 377 in control practices (mortality hazard ratio [HR] 1·06, 95% CI 0·90-1·25). We noted no significant reduction in cardiovascular (HR 1·02, 95% CI 0·75-1·38), cancer (1·08, 0·90-1·30), or diabetes-related mortality (1·26, 0·75-2·10) associated with invitation to screening. In this large UK sample, screening for type 2 diabetes in patients at increased risk was not associated with a reduction in all-cause, cardiovascular, or diabetes-related mortality within 10 years. The benefits of screening might be smaller than expected and restricted to individuals with detectable disease. Wellcome Trust; UK Medical Research Council; National Health Service research and development support; UK National Institute for Health Research; University of Aarhus, Denmark; Bio-Rad. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Screening for type 2 diabetes and population mortality over 10 years (ADDITION-Cambridge): a cluster-randomised controlled trial

    PubMed Central

    Simmons, Rebecca K; Echouffo-Tcheugui, Justin B; Sharp, Stephen J; Sargeant, Lincoln A; Williams, Kate M; Prevost, A Toby; Kinmonth, Ann Louise; Wareham, Nicholas J; Griffin, Simon J

    2012-01-01

    Summary Background The increasing prevalence of type 2 diabetes poses a major public health challenge. Population-based screening and early treatment for type 2 diabetes could reduce this growing burden. However, uncertainty persists around the benefits of screening for type 2 diabetes. We assessed the effect of a population-based stepwise screening programme on mortality. Methods In a pragmatic parallel group, cluster-randomised trial, 33 general practices in eastern England were randomly assigned by the method of minimisation in an unbalanced design to: screening followed by intensive multifactorial treatment for people diagnosed with diabetes (n=15); screening plus routine care of diabetes according to national guidelines (n=13); and a no-screening control group (n=5). The study population consisted of 20 184 individuals aged 40–69 years (mean 58 years), at high risk of prevalent undiagnosed diabetes, on the basis of a previously validated risk score. In screening practices, individuals were invited to a stepwise programme including random capillary blood glucose and glycated haemoglobin (HbA1c) tests, a fasting capillary blood glucose test, and a confirmatory oral glucose tolerance test. The primary outcome was all-cause mortality. All participants were flagged for mortality surveillance by the England and Wales Office of National Statistics. Analysis was by intention-to-screen and compared all-cause mortality rates between screening and control groups. This study is registered, number ISRCTN86769081. Findings Of 16 047 high-risk individuals in screening practices, 15 089 (94%) were invited for screening during 2001–06, 11 737 (73%) attended, and 466 (3%) were diagnosed with diabetes. 4137 control individuals were followed up. During 184 057 person-years of follow up (median duration 9·6 years [IQR 8·9–9·9]), there were 1532 deaths in the screening practices and 377 in control practices (mortality hazard ratio [HR] 1·06, 95% CI 0·90–1·25). We noted no significant reduction in cardiovascular (HR 1·02, 95% CI 0·75–1·38), cancer (1·08, 0·90–1·30), or diabetes-related mortality (1·26, 0·75–2·10) associated with invitation to screening. Interpretation In this large UK sample, screening for type 2 diabetes in patients at increased risk was not associated with a reduction in all-cause, cardiovascular, or diabetes-related mortality within 10 years. The benefits of screening might be smaller than expected and restricted to individuals with detectable disease. Funding Wellcome Trust; UK Medical Research Council; National Health Service research and development support; UK National Institute for Health Research; University of Aarhus, Denmark; Bio-Rad. PMID:23040422

  9. Comparing short versions of the AUDIT in a community-based survey of young people

    PubMed Central

    2013-01-01

    Background The 10-item Alcohol Use Disorders Identification Test (AUDIT-10) is commonly used to monitor harmful alcohol consumption among high-risk groups, including young people. However, time and space constraints have generated interest for shortened versions. Commonly used variations are the AUDIT-C (three questions) and the Fast Alcohol Screening Test (FAST) (four questions), but their utility in screening young people in non-clinical settings has received little attention. Methods We examined the performance of established and novel shortened versions of the AUDIT in relation to the full AUDIT-10 in a community-based survey of young people (16–29 years) attending a music festival in Melbourne, Australia (January 2010). Among those reporting drinking alcohol in the previous 12 months, the following statistics were systematically assessed for all possible combinations of three or four AUDIT items and established AUDIT variations: Cronbach’s alpha (internal consistency), variance explained (R2) and Pearson’s correlation coefficient (concurrent validity). For our purposes, novel shortened AUDIT versions considered were required to represent all three AUDIT domains and include item 9 on alcohol-related injury. Results We recruited 640 participants (68% female) reporting drinking in the previous 12 months. Median AUDIT-10 score was 10 in males and 9 in females, and 127 (20%) were classified as having at least high-level alcohol problems according to WHO classification. The FAST scored consistently high across statistical measures; it explained 85.6% of variance in AUDIT-10, correlation with AUDIT-10 was 0.92, and Cronbach’s alpha was 0.66. A number of novel four-item AUDIT variations scored similarly high. Comparatively, the AUDIT-C scored substantially lower on all measures except internal consistency. Conclusions Numerous abbreviated variations of the AUDIT may be a suitable alternative to the AUDIT-10 for classifying high-level alcohol problems in a community-based population of young Australians. Four-item AUDIT variations scored more consistently high across all evaluated statistics compared to three-item combinations. Novel AUDIT versions may be more effective than many established shortened versions as an alternative screening tool to the AUDIT-10 to measure hazardous or harmful alcohol consumption in this population. PMID:23556543

  10. Design of stepwise screening for prediabetes and type 2 diabetes based on costs and cases detected.

    PubMed

    de Graaf, Gimon; Postmus, Douwe; Bakker, Stephan J L; Buskens, Erik

    2015-09-01

    To provide insight into the trade-off between cost per case detected (CPCD) and the detection rate in questionnaire-based stepwise screening for impaired fasting glucose and undiagnosed type 2 diabetes. We considered a stepwise screening in which individuals whose risk score exceeds a predetermined cutoff value are invited for further blood glucose testing. Using individual patient data to determine questionnaire sensitivity and specificity and external sources to determine screening costs and patient response rates, we rolled back a decision tree to estimate the CPCD and the detection rate for all possible cutoffs on the questionnaire. We found a U-shaped relation between CPCD and detection rate, with high costs per case detected at very low and very high detection rates. Changes in patient response rates had a large impact on both the detection rate and the CPCD, whereas screening costs and questionnaire accuracy mainly impacted the CPCD. Our applied method makes it possible to identify a range of efficient cutoffs where higher detection rates can be achieved at an additional cost per detected patient. This enables decision makers to choose an optimal cutoff based on their willingness to pay for additional detected patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Dynamics of subcellular compartmentalization of steroid receptors in living cells as a strategic screening method to determine the biological impact of suspected endocrine disruptors.

    PubMed

    Tyagi, Rakesh Kumar

    2003-04-01

    Although a number of screening methods being used for identifying potential endocrine disruptors have generated a wealth of information, a search for alternative combination of methods is still needed to overcome experimental artefacts. There are no generally accepted or validated screening methods for monitoring and studying impact of environmental endocrine disruptors. Also, no single assay can accurately predict all the deleterious effects of endocrine disruptors. For this reason various environmental protection agencies, mainly European and US, have urged that a battery of tests in current use need to be designed to assess their adequacy in detecting the effects of endocrine disruptors. Some details about endocrine disruptors and screening programs can be found at http://www.epa.gov/scipoly/oscpendo/whatis.htm. Several studies in recent years have used fusion proteins between steroid receptors (estrogen, androgen, progesterone, etc.) and green fluorescent protein (GFP) that can serve as an alternative potent screening method to study intracellular dynamics of receptors in living cells. An approach employing nucleocytoplasmic trafficking of steroid receptors as a parameter in response to potential xenobiotic chemicals in living cells may prove to be promising in terms of being direct, fast, reliable, simple and inexpensive. Copyright 2003 Elsevier Science Ltd.

  12. Perceived cognitive difficulties and cognitive test performance as predictors of employment outcomes in people with multiple sclerosis.

    PubMed

    Honan, Cynthia A; Brown, Rhonda F; Batchelor, Jennifer

    2015-02-01

    Perceived cognitive difficulties and cognitive impairment are important determinants of employment in people with multiple sclerosis (pwMS). However, it is not clear how they are related to adverse work outcomes and whether the relationship is influenced by depressive symptoms. Thus, this study examined perceived and actual general cognitive and prospective memory function, and cognitive appraisal accuracy, in relation to adverse work outcomes. The possible mediating and/or moderating role of depression was also examined. A cross-sectional community-based sample of 111 participants (33 males, 78 females) completed the Multiple Sclerosis Work Difficulties Questionnaire (MSWDQ), Beck Depression Inventory - Fast Screen (BDI-FS), and questions related to their current or past employment. They then underwent cognitive testing using the Screening Examination for Cognitive Impairment, Auditory Consonant Trigrams test, Zoo Map Test, and Cambridge Prospective Memory Test. Perceived general cognitive and prospective memory difficulties in the workplace and performance on the respective cognitive tests were found to predict unemployment and reduced work hours since MS diagnosis due to MS. Depression was also related to reduced work hours, but it did not explain the relationship between perceived cognitive difficulties and the work outcomes. Nor was it related to cognitive test performance. The results highlight a need to address the perceptions of cognitive difficulties together with cognitive impairment and levels of depression in vocational rehabilitation programs in pwMS.

  13. Phenotypic and genomic analysis of a fast neutron mutant population resource in soybean

    USDA-ARS?s Scientific Manuscript database

    Mutagenized populations have become indispensable resources for introducing variation and studying gene function in plant genomics research. We utilized fast neutron radiation to induce deletion mutations in the soybean genome and phenotypically screened the resulting population. We exposed approxim...

  14. [Research of preparation craft of Danshen phenolic acid fast release unit in multi-drug delivery system of Tongmai micro-pellets].

    PubMed

    Chen, Bin; Xiao, Wei; Jia, Xiao-Bin; Huang, Yang

    2012-07-01

    To prepare Danshen phenolic acid fast release micro-pellets and study its preparation craft. The factors which could impact yield, extrude shaping, dissolution of Danshen phenolic acid micro-pellets such as wetting agent, drug loading dose, adjuvant, lactose dose, disintegrant, CMS-Na dose and wetting agent dose was investigated. The optimum preparation craft of Danshen phenolic acid fast release micro-pellets was screened out by orhogonal design. Formula of Danshen phenolic acid fast release micro-pellets was calculated as volume dose 50 g. The formula was as follows: principal agent 22.5 g, lactose 5 g, CMS-Na 2 g, MCC 20.5 g, 27 mL 30% ethanol as wetting agent. Extrusion-spheronization was applied. The optimum conditions were screened out as follows: extrusion frequency (25 Hz), spheronization machine frequency (50 Hz), spheronization time (4 min). The process was scientific and rational. The preparation is stable settles basis for multi-drug delivery system of Tongmai micro-pellets.

  15. Performance index: An expeditious tool to screen for improved drought resistance in the Lathyrus genus.

    PubMed

    Silvestre, Susana; Araújo, Susana de Sousa; Vaz Patto, Maria Carlota; Marques da Silva, Jorge

    2014-07-01

    Some species of the Lathyrus genus are among the most promising crops for marginal lands, with high resilience to drought, flood, and fungal diseases, combined with high yields and seed nutritional value. However, lack of knowledge on the mechanisms underlying its outstanding performance and methodologies to identify elite genotypes has hampered its proper use in breeding. Chlorophyll a fast fluorescence transient (JIP test), was used to evaluate water deficit (WD) resistance in Lathyrus genus. Our results reveal unaltered photochemical values for all studied genotypes showing resistance to mild WD. Under severe WD, two Lathyrus sativus genotypes showed remarkable resilience maintaining the photochemical efficiency, contrary to other genotypes studied. Performance index (PIABS) is the best parameter to screen genotypes with improved performance and grain production under WD. Moreover, we found that JIP indices are good indicators of genotypic grain production under WD. Quantum yield of electron transport (ϕEo) and efficiency with which trapped excitons can move electrons further than QA (ψ0) revealed as important traits related to improved photosynthetic performance and should be exploited in future Lathyrus germplasm improvements. The JIP test herein described showed to be an expeditious tool to screen and to identify elite genotypes with improved drought resistance.

  16. Action potential-based MEA platform for in vitro screening of drug-induced cardiotoxicity using human iPSCs and rat neonatal myocytes.

    PubMed

    Jans, Danny; Callewaert, Geert; Krylychkina, Olga; Hoffman, Luis; Gullo, Francesco; Prodanov, Dimiter; Braeken, Dries

    2017-09-01

    Drug-induced cardiotoxicity poses a negative impact on public health and drug development. Cardiac safety pharmacology issues urged for the preclinical assessment of drug-induced ventricular arrhythmia leading to the design of several in vitro electrophysiological screening assays. In general, patch clamp systems allow for intracellular recordings, while multi-electrode array (MEA) technology detect extracellular activity. Here, we demonstrate a complementary metal oxide semiconductor (CMOS)-based MEA system as a reliable platform for non-invasive, long-term intracellular recording of cardiac action potentials at high resolution. Quinidine (8 concentrations from 10 -7 to 2.10 -5 M) and verapamil (7 concentrations from 10 -11 to 10 -5 M) were tested for dose-dependent responses in a network of cardiomyocytes. Electrophysiological parameters, such as the action potential duration (APD), rates of depolarization and repolarization and beating frequency were assessed. In hiPSC, quinidine prolonged APD with EC 50 of 2.2·10 -6 M. Further analysis indicated a multifactorial action potential prolongation by quinidine: (1) decreasing fast repolarization with IC 50 of 1.1·10 -6 M; (2) reducing maximum upstroke velocity with IC 50 of 2.6·10 -6 M; and (3) suppressing spontaneous activity with EC 50 of 3.8·10 -6 M. In rat neonatal cardiomyocytes, verapamil blocked spontaneous activity with EC 50 of 5.3·10 -8 M and prolonged the APD with EC 50 of 2.5·10 -8 M. Verapamil reduced rates of fast depolarization and repolarization with IC 50 s of 1.8 and 2.2·10 -7 M, respectively. In conclusion, the proposed action potential-based MEA platform offers high quality and stable long-term recordings with high information content allowing to characterize multi-ion channel blocking drugs. We anticipate application of the system as a screening platform to efficiently and cost-effectively test drugs for cardiac safety. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Rapid Screening Method for New Psychoactive Substances of Forensic Interest: Electrochemistry and Analytical Determination of Phenethylamines Derivatives (NBOMe) via Cyclic and Differential Pulse Voltammetry.

    PubMed

    Andrade, Ana Flávia B; Mamo, Samuel Kasahun; Gonzalez-Rodriguez, Jose

    2017-02-07

    The NBOMe derivatives are phenethylamines derived from the 2C class of hallucinogens. Only a few human pharmacologic studies have been conducted on these drugs, and several cases of intoxication and deaths have been reported. Presently, NBOMe are not a part of the routine drugs-of-abuse screening procedure for many police forces, and there are no rapid immunoassay screening tests that can detect the presence of those compounds. In this Article, the voltammetric behavior of 25B NBOMe and 25I NBOMe were investigated and their electroanalytical characteristics determined for the first time. A novel, fast, and sensitive screening method for the identification of the two most common NBOMes (25B-NBOMe and 25I-NBOMe) in real samples is reported. The method uses the electrochemical oxidation of these molecules to produce an analytical signal that can be related to the NBOMe concentration with an average lower limit of quantitation of 0.01 mg/mL for both of them. The method is selective enough to identify the two compounds individually, even given the great similarity in their structure.

  18. High Voltage Test-Stand Research Done on ICRF Antenna Elements of the High-Harmonic Fast-Wave System of NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, R. J.; Ahn, J.W.; Bortolon, A.

    The twelve-strap high-harmonic fast-wave (HHFW) antenna on NSTX has exhibited a high-voltage standoff around 25 kV during previous experimental campaigns; this standoff needs to be improved for increased power coupling. During the recent NSTX-U upgrade period, a test-stand was set up with two antenna straps along with Faraday screens for testing purposes. Using a diagnostic suite consisting of a fast camera, a residual gas analyzer, a pressure gage, high-voltage probes, and an infrared camera, several interesting discoveries were made, leading to possible improvements of the antenna RF voltage operation level. First, arcing was observed outside the Faraday shields towards themore » low-voltage ("grounded") end of the straps (faraday shield box ends); this arcing was successfully eliminated by installing an additional grounding point between the Faraday shield box and the vessel wall. Second, considerable outgassing was observed during the RF pulse and the amount of outgassing was found to decrease with increasing RF power, possibly indicative of multipacting. Finally, infrared camera measurements of heating on the Faraday shield assembly suggest that the return currents on the Faraday shield box are highly localized at the box sides and possibly account for the pressure increase observed. Computations of these RF currents using Microwave Studio show qualitative agreement with the heated regions. New grounding points between the antenna box and the vessel have been implemented in NSTX-U, where future tests will be done to determine if the high-voltage standoff has improved. Further antenna improvements will be sought through future experiments on the test stand.« less

  19. Ammunition identification by means of the organic analysis of gunshot residues using Raman spectroscopy.

    PubMed

    López-López, María; Delgado, Juan José; García-Ruiz, Carmen

    2012-04-17

    The ability to unequivocally identify a gunshot residue (GSR) when a firearm is discharged is a very important and crucial part of crime scene investigation. To date, the great majority of the analyses have focused on the inorganic components of GSR, but the introduction of "lead-free" or "nontoxic" ammunitions makes it difficult to prevent false negatives. This study introduces a fast methodology for the organic analysis of GSR using Raman spectroscopy. Six different types of ammunition were fired at short distances into cloth targets, and the Raman spectra produced by the GSR were measured and compared with the spectra from the unfired gunpowder ammunition. The GSR spectrum shows high similarity to the spectrum of the unfired ammunition, allowing the GSR to be traced to the ammunition used. Additionally, other substances that might be found on the victim's, shooter's, or suspect's clothes and might be confused with GSR, such as sand, dried blood, or black ink from a common ballpoint pen, were analyzed to test the screening capability of the Raman technique. The results obtained evidenced that Raman spectroscopy is a useful screening tool when fast analysis is desired and that little sample preparation is required for the analysis of GSR evidence.

  20. Screen-Printed Photochromic Textiles through New Inks Based on SiO2@naphthopyran Nanoparticles.

    PubMed

    Pinto, Tânia V; Costa, Paula; Sousa, Céu M; Sousa, Carlos A D; Pereira, Clara; Silva, Carla J S M; Pereira, Manuel Fernando R; Coelho, Paulo J; Freire, Cristina

    2016-10-26

    Photochromic silica nanoparticles (SiO 2 @NPT), fabricated through the covalent immobilization of silylated naphthopyrans (NPTs) based on 2H-naphtho[1,2-b]pyran (S1, S2) and 3H-naphtho[2,1-b]pyran (S3, S4) or through the direct adsorption of the parent naphthopyrans (1, 3) onto silica nanoparticles (SiO 2 NPs), were successfully incorporated onto cotton fabrics by a screen-printing process. Two aqueous acrylic- (AC-) and polyurethane- (PU-) based inks were used as dispersing media. All textiles exhibited reversible photochromism under UV and solar irradiation, developing fast responses and intense coloration. The fabrics coated with SiO 2 @S1 and SiO 2 @S2 showed rapid color changes and high contrasts (ΔE* ab = 39-52), despite presenting slower bleaching kinetics (2-3 h to fade to the original color), whereas the textiles coated with SiO 2 @S3 and SiO 2 @S4 exhibited excellent engagement between coloration and decoloration rates (coloration and fading times of 1 and 2 min, respectively; ΔE* ab = 27-53). The PU-based fabrics showed excellent results during the washing fastness tests, whereas the AC-based textiles evidenced good results only when a protective transfer film was applied over the printed design.

  1. Identifying developmental coordination disorder: MOQ-T validity as a fast screening instrument based on teachers' ratings and its relationship with praxic and visuospatial working memory deficits.

    PubMed

    Giofrè, David; Cornoldi, Cesare; Schoemaker, Marina M

    2014-12-01

    The present study was devoted to test the validity of the Italian adaptation of the Motor Observation Questionnaire for Teachers (MOQ-T, Schoemaker, Flapper, Reinders-Messelink, & De Kloet, 2008) as a fast screening instrument, based on teachers' ratings, for detecting developmental coordination disorders symptoms and to study its relationship with praxic and visuospatial working memory deficits. In a first study on a large sample of children, we assessed the reliability and structure of the Italian adaptation of the MOQ-T. Results showed a good reliability of the questionnaire and a hierarchical structure with two first-order factors (reflecting motor and handwriting skills), which are influenced by a second-order factor (general motor function) at the top. In a second study, we looked at the external validity of the MOQ-T and found that children with symptoms of Developmental Coordination Disorder (children with high scores on the MOQ-T) also had difficulty reproducing gestures, either imitating others or in response to verbal prompts. Our results also showed that children with high MOQ-T scores had visuospatial WM impairments. The theoretical and clinical implications of these findings are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Fast detection and characterization of organic and inorganic gunshot residues on the hands of suspects by CMV-GC-MS and LIBS.

    PubMed

    Tarifa, Anamary; Almirall, José R

    2015-05-01

    A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Young Men’s Views Toward the Barriers and Facilitators of Internet-Based Chlamydia Trachomatis Screening: Qualitative Study

    PubMed Central

    McDaid, Lisa

    2013-01-01

    Background There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. Objective This paper explores young men’s views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. Methods This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men’s knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Results Men’s Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. Conclusions The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women. PMID:24300158

  4. Young men's views toward the barriers and facilitators of Internet-based Chlamydia trachomatis screening: qualitative study.

    PubMed

    Lorimer, Karen; McDaid, Lisa

    2013-12-03

    There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. This paper explores young men's views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men's knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Men's Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women.

  5. Formulation design of taste-masked particles, including famotidine, for an oral fast-disintegrating dosage form.

    PubMed

    Mizumoto, Takao; Tamura, Tetsuya; Kawai, Hitoshi; Kajiyama, Atsushi; Itai, Shigeru

    2008-04-01

    In this study, the taste-masking of famotidine, which could apply to any fast-disintegrating tablet, was investigated using the spray-dry method. The target characteristics of taste-masked particles were set as follows: the dissolution rate is not to be more than 30% at 1 min and not less than 85% at 15 min, and the particle size is not to be more than 150 microm in diameter to avoid a gritty feeling in the mouth. The target dissolution profiles of spray-dried particles consisting of Aquacoat ECD30 and Eudragit NE30D or triacetin was accomplished by the screening of formulas and the appropriate lab-scale manufacturing conditions. Lab-scale testing produced taste-masked particles that met the formulation targets. On the pilot scale, spray-dried particles with attributes, such as dissolution rate and particle size, of the same quality were produced, and reproducibility was also confirmed. This confirmed that the spray-dry method produced the most appropriate taste-masked particles for fast-disintegrating dosage forms.

  6. Screening acidic zeolites for catalytic fast pyrolysis of biomass and its components

    USDA-ARS?s Scientific Manuscript database

    Zeolites have been shown to effectively promote cracking reactions during pyrolysis resulting in highly deoxygenated and hydrocarbon-rich compounds and stable pyrolysis oil product. Py/GC-MS was employed to study the catalytic fast pyrolysis of lignocellulosic biomass samples comprising oak, corn...

  7. CHAM: a fast algorithm of modelling non-linear matter power spectrum in the sCreened HAlo Model

    NASA Astrophysics Data System (ADS)

    Hu, Bin; Liu, Xue-Wen; Cai, Rong-Gen

    2018-05-01

    We present a fast numerical screened halo model algorithm (CHAM, which stands for the sCreened HAlo Model) for modelling non-linear power spectrum for the alternative models to Λ cold dark matter. This method has three obvious advantages. First of all, it is not being restricted to a specific dark energy/modified gravity model. In principle, all of the screened scalar-tensor theories can be applied. Secondly, the least assumptions are made in the calculation. Hence, the physical picture is very easily understandable. Thirdly, it is very predictable and does not rely on the calibration from N-body simulation. As an example, we show the case of the Hu-Sawicki f(R) gravity. In this case, the typical CPU time with the current parallel PYTHON script (eight threads) is roughly within 10 min. The resulting spectra are in a good agreement with N-body data within a few percentage accuracy up to k ˜ 1 h Mpc-1.

  8. A novel fast-neutron tomography system based on a plastic scintillator array and a compact D-D neutron generator.

    PubMed

    Adams, Robert; Zboray, Robert; Prasser, Horst-Michael

    2016-01-01

    Very few experimental imaging studies using a compact neutron generator have been published, and to the knowledge of the authors none have included tomography results using multiple projection angles. Radiography results with a neutron generator, scintillator screen, and camera can be seen in Bogolubov et al. (2005), Cremer et al. (2012), and Li et al. (2014). Comparable results with a position-sensitive photomultiplier tube can be seen in Popov et al. (2011). One study using an array of individual fast neutron detectors in the context of cargo scanning for security purposes is detailed in Eberhardt et al. (2005). In that case, however, the emphasis was on very large objects with a resolution on the order of 1cm, whereas this study focuses on less massive objects and a finer spatial resolution. In Andersson et al. (2014) three fast neutron counters and a D-T generator were used to perform attenuation measurements of test phantoms. Based on the axisymmetry of the test phantoms, the single-projection information was used to calculate radial attenuation distributions of the object, which was compared with the known geometry. In this paper a fast-neutron tomography system based on an array of individual detectors and a purpose-designed compact D-D neutron generator is presented. Each of the 88 detectors consists of a plastic scintillator read out by two Silicon photomultipliers and a dedicated pulse-processing board. Data acquisition for all channels was handled by four single-board microcontrollers. Details of the individual detector design and testing are elaborated upon. Using the complete array, several fast-neutron images of test phantoms were reconstructed, one of which was compared with results using a Co-60 gamma source. The system was shown to be capable of 2mm resolution, with exposure times on the order of several hours per reconstructed tomogram. Details about these measurements and the analysis of the reconstructed images are given, along with a discussion of the capabilities of the system and its outlook. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Abbreviated breast magnetic resonance protocol: Value of high-resolution temporal dynamic sequence to improve lesion characterization.

    PubMed

    Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle

    2017-10-01

    To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Reliable Screening of Dye Phototoxicity by Using a Caenorhabditis elegans Fast Bioassay

    PubMed Central

    Bianchi, Javier Ignacio; Stockert, Juan Carlos; Buzz, Lucila Ines; Blázquez-Castro, Alfonso; Simonetta, Sergio Hernán

    2015-01-01

    Phototoxicity consists in the capability of certain innocuous molecules to become toxic when subjected to suitable illumination. In order to discover new photoactive drugs or characterize phototoxic pollutants, it would be advantageous to use simple biological tests of phototoxicy. In this work, we present a pilot screening of 37 dyes to test for phototoxic effects in the roundworm Caenorhabditis elegans. Populations of this nematode were treated with different dyes, and subsequently exposed to 30 min of white light. Behavioral outcomes were quantified by recording the global motility using an infrared tracking device (WMicrotracker). Of the tested compounds, 17 dyes were classified as photoactive, being phloxine B, primuline, eosin Y, acridine orange and rose Bengal the most phototoxic. To assess photoactivity after uptake, compounds were retested after washing them out of the medium before light irradiation. Dye uptake into the worms was also analyzed by staining or fluorescence. All the positive drugs were incorporated by animals and produced phototoxic effects after washing. We also tested the stress response being triggered by the treatments through reporter strains. Endoplasmic reticulum stress response (hsp-4::GFP strain) was activated by 22% of phototoxic dyes, and mitochondrial stress response (hsp-6::GFP strain) was induced by 16% of phototoxic dyes. These results point to a phototoxic perturbation of the protein functionality and an oxidative stress similar to that reported in cell cultures. Our work shows for the first time the feasibility of C. elegans for running phototoxic screenings and underscores its application on photoactive drugs and environmental pollutants assessment. PMID:26039060

  11. Can YAG screen accept LEReC bunch train?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S.; Thieberger, P.; Miller, T.

    2016-05-18

    LEReC RF diagnostic beamline is supposed to accept 250 us long pulse trains of 1.6 MeV – 2.6 MeV (kinetic energy) electrons. This beamline is equipped with YAG profile monitor. Since we are interested in observing only the last macro bunch in the train, one of the possibilities is to install a fast kicker and a dedicated dump upstream of the YAG screen (and related diagnostics equipment). This approach is expensive and challenging from engineering point of view. Another possibility is to send the whole pulse train to the YAG screen and to use a fast gated camera (such asmore » Imperex B0610 with trigger jitter under 60ns) to observe the image from the last pulse only. In this paper we study the feasibility of the last approach.« less

  12. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less

  13. Time and position sensitive single photon detector for scintillator read-out

    NASA Astrophysics Data System (ADS)

    Schössler, S.; Bromberger, B.; Brandis, M.; Schmidt, L. Ph H.; Tittelmeier, K.; Czasch, A.; Dangendorf, V.; Jagutzki, O.

    2012-02-01

    We have developed a photon counting detector system for combined neutron and γ radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy γ radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate γ energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).

  14. Fast-neutron/gamma-ray radiography scanner for the detection of contraband in air cargo containers

    NASA Astrophysics Data System (ADS)

    Eberhardt, J.; Liu, Y.; Rainey, S.; Roach, G.; Sowerby, B.; Stevens, R.; Tickner, J.

    2006-05-01

    There is a worldwide need for efficient inspection of cargo containers at airports, seaports and road border crossings. The main objectives are the detection of contraband such as illicit drugs, explosives and weapons. Due to the large volume of cargo passing through Australia's airports every day, it is critical that any scanning system should be capable of working on unpacked or consolidated cargo, taking at most 1-2 minutes per container. CSIRO has developed a fast-neutron/gamma-ray radiography (FNGR) method for the rapid screening of air freight. By combining radiographs obtained using 14 MeV neutrons and 60Co gamma-rays, high resolution images showing both density and material composition are obtained. A near full-scale prototype scanner has been successfully tested in the laboratory. With the support of the Australian Customs Service, a full-scale scanner has recently been installed and commissioned at Brisbane International Airport.

  15. Evaluation of (GTG)5-PCR for rapid identification of Streptococcus mutans.

    PubMed

    Svec, Pavel; Nováková, Dana; Zácková, Lenka; Kukletová, Martina; Sedlácek, Ivo

    2008-11-01

    Repetitive sequence-based polymerase chain reaction (PCR) fingerprinting using the (GTG)(5) primer was applied for fast screening of bacterial strains isolated from dental plaque of early childhood caries (ECC)-affected children. A group of 29 Gram-positive bacteria was separated into a homogeneous cluster together with Streptococcus mutans reference strains and constituted an aberrant branch after the numerical analysis of (GTG)(5)-PCR fingerprints. Automated ribotyping with EcoRI restriction enzyme (RiboPrinter microbial characterization system) revealed high genetic heterogeneity among the tested group and proved to be a good tool for strain-typing purposes. Further characterization of the studied strains was achieved by extensive phenotyping and whole-cell protein fingerprinting and confirmed all the strains as S. mutans representatives. Obtained results showed rep-PCR fingerprinting with the (GTG)(5) primer to be a fast and reliable method for identification of S. mutans.

  16. Satisfaction, discomfort, obligations, and concerns in population-based breast cancer screening: cross-sectional study in a Danish population.

    PubMed

    Gabel, Pernille; Larsen, Mette Bach; Nielsen, Pernille Bjørnholt; Svendstrup, Dorte Brandt; Andersen, Berit

    2017-07-14

    Potential barriers to breast cancer screening adherence include patient satisfaction, as well as pain, feeling obliged to participate, and other concerns that might compromise the level of satisfaction. The present study aimed to assess the overall satisfaction of Danish citizens with their breast cancer screening experiences, as well as their level of discomfort, concerns, and feelings of obligation to participate. Furthermore, we analyzed the associations between overall satisfaction and the remaining outcomes. Questionnaires were mailed to 3000 women in the Central Denmark Region who received screening examination results in the fall of 2013. The questionnaire assessed satisfaction (overall, telephone hot-line, and web-based self-service), discomfort (pain and boundaries of modesty), concerns (at invitation, while waiting for results, and after receiving results), and feelings of obligation to participate. Background information was retrieved from Statistics Denmark. Pearson's chi-square test was used to test differences in outcomes and demographic characteristic distributions between respondents and non-respondents and highly satisfied vs. less satisfied participants. Prevalence ratios (PR) with 95% CI were assessed using Poisson regression with robust variance, to estimate associations between satisfaction and the remaining outcomes. Among the participants, 70.3% and 29.4%, respectively, reported really good and good impressions of the screening program. Lower satisfaction was associated with feeling pain (prevalence ratio (PR), 0.82), feeling that modesty boundaries were transgressed (PR, 0.79), experiencing screening-induced concerns (PR, 0.84), and feeling obliged to participate (PR, 0.96). Of the participants, 36.2% and 12.9%, respectively, felt very much and moderately obliged to participate. A total of 72.6% reported no screening-induced concerns, including 73.3% of those with negative screening results and 38.1% of those with positive screening results. Overall satisfaction with breast cancer screening was very high, but discomfort, feelings of obligation, and concerns were associated with lower satisfaction levels. A continuing focus on high service in breast cancer screening is important for achieving the highest benefit from the program. This includes initiatives to employ the least painful techniques, to respect the patients' modesty as much as possible, and to deliver fast screening results and thus minimize concerns among women awaiting results.

  17. Development of a canine model to enable the preclinical assessment of pH-dependent absorption of test compounds.

    PubMed

    Fancher, R Marcus; Zhang, Hongjian; Sleczka, Bogdan; Derbin, George; Rockar, Richard; Marathe, Punit

    2011-07-01

    A preclinical canine model capable of predicting a compound's potential for pH-dependent absorption in humans was developed. This involved the surgical insertion of a gastrostomy feeding tube into the stomach of a beagle dog. The tube was sutured in position to allow frequent withdrawal of gastric fluid for pH measurement. Therefore, it was possible to measure pH in the stomach and assess the effect of gastric pH-modifying agents on the absorption of various test compounds. Fasted gastric pH in the dog showed considerable inter- and intra-animal variability. Pretreatment of pentagastrin (6 µg/kg intramuscularly) 20 min prior to test compound administration was determined to be adequate for simulating fasting stomach pH in humans. Pretreatment with famotidine [40 mg orally] 1 h prior to test compound administration was determined to be adequate for simulating human gastric pH when acid-reducing agents are coadministered. Pentagastrin and famotidine pretreatments were used to test two discovery compounds and distinct differences in their potential for pH-dependent absorption were observed. The model described herein can be used preclinically to screen out compounds, differentiate compounds, and support the assessment of various formulation- and prodrug-based strategies to mitigate the pH effect. Copyright © 2011 Wiley-Liss, Inc. and the American Pharmacists Association

  18. Rapid screening of fatty acid alkyl esters in olive oils by time domain reflectometry.

    PubMed

    Berardinelli, Annachiara; Ragni, Luigi; Bendini, Alessandra; Valli, Enrico; Conte, Lanfranco; Guarnieri, Adriano; Toschi, Tullia Gallina

    2013-11-20

    The main aim of the present research is to assess the possibility of quickly screening fatty acid alkyl esters (FAAE) in olive oils using time domain reflectometry (TDR) and partial least-squares (PLS) multivariate statistical analysis. Eighteen virgin olive oil samples with fatty acid alkyl ester contents and fatty acid ethyl ester/methyl ester ratios (FAEE/FAME) ranging from 3 to 100 mg kg(-1) and from 0.3 to 2.6, respectively, were submitted to tests with time domain resolution of 1 ps. The results obtained in test set validation demonstrated that this new and fast analytical approach is able to predict FAME, FAEE, and FAME + FAEE contents with R(2) values of 0.905, 0.923, and 0.927, respectively. Further measurements on mixtures between olive oil and FAAE standards confirmed that the prediction is based on a direct influence of fatty acid alkyl esters on the TDR signal. The suggested technique appeared potentially suitable for monitoring one of the most important quality attribute of the olive oil in the extraction process.

  19. The urgent need for universally applicable simple screening procedures and diagnostic criteria for gestational diabetes mellitus--lessons from projects funded by the World Diabetes Foundation.

    PubMed

    Nielsen, Karoline Kragelund; de Courten, Maximilian; Kapur, Anil

    2012-01-01

    To address the risks of adverse pregnancy outcomes and future type 2 diabetes associated with gestational diabetes mellitus (GDM), its early detection and timely treatment is essential. In the absence of an international consensus, multiple different guidelines on screening and diagnosis of GDM have existed for a long time. This may be changing with the publication of the recommendations by the International Association of Diabetes and Pregnancy Study Groups. However, none of these guidelines take into account evidence from or ground realities of resource-poor settings. This study aimed to investigate whether GDM projects supported by the World Diabetes Foundation in developing countries utilize any of the internationally recommended guidelines for screening and diagnosis of GDM, explore experiences on applicability and usefulness of the guidelines and barriers if any, in implementing the guidelines. These projects have reached out to thousands of pregnant women through capacity building and improvement of access to GDM screening and diagnosis in the developing world and therefore provide a rich field experience on the applicability of the guidelines in resource-poor settings. A mixed methods approach using questionnaires and interviews was utilised to review 11 GDM projects. Two projects were conducted by the same partner; interviews were conducted in person or via phone by the first author with nine project partners and one responded via email. The interviews were analysed using content analysis. The projects use seven different screening procedures and diagnostic criteria and many do not completely adhere to one guideline alone. Various challenges in adhering to the recommendations emerged in the interviews, including problems with screening women during the recommended time period, applicability of some of the listed risk factors used for (pre-)screening, difficulties with reaching women for testing in the fasting state, time consuming nature of the tests, intolerance to high glucose load due to nausea, need for repeat tests, issues with scarcity of test consumables and lack of equipment making some procedures impossible to follow. Though an international consensus on screening and diagnosis for GDM is welcome, it should ensure that the recommendations take into account feasibility and applicability in low resource settings to ensure wider usage. We need to move away from purely academic discussions focusing on sensitivity and specificity to also include what can actually be done at the basic care level.

  20. Fabrication and Characterization of Flexible and Miniaturized Humidity Sensors Using Screen-Printed TiO2 Nanoparticles as Sensitive Layer

    PubMed Central

    Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna

    2017-01-01

    This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063

  1. Development of a qualitative real-time PCR method to detect 19 targets for identification of genetically modified organisms.

    PubMed

    Peng, Cheng; Wang, Pengfei; Xu, Xiaoli; Wang, Xiaofu; Wei, Wei; Chen, Xiaoyun; Xu, Junfeng

    2016-01-01

    As the amount of commercially available genetically modified organisms (GMOs) grows recent years, the diversity of target sequences for molecular detection techniques are eagerly needed. Considered as the gold standard for GMO analysis, the real-time PCR technology was optimized to produce a high-throughput GMO screening method. With this method we can detect 19 transgenic targets. The specificity of the assays was demonstrated to be 100 % by the specific amplification of DNA derived from reference material from 20 genetically modified crops and 4 non modified crops. Furthermore, most assays showed a very sensitive detection, reaching the limit of ten copies. The 19 assays are the most frequently used genetic elements present in GM crops and theoretically enable the screening of the known GMO described in Chinese markets. Easy to use, fast and cost efficient, this method approach fits the purpose of GMO testing laboratories.

  2. A Capsule-Type Electromagnetic Acoustic Transducer for Fast Screening of External Corrosion in Nonmagnetic Pipes.

    PubMed

    Li, Yong; Cai, Rui; Yan, Bei; Zainal Abidin, Ilham Mukriz; Jing, Haoqing; Wang, Yi

    2018-05-28

    For fuel transmission and structural strengthening, small-diameter pipes of nonmagnetic materials are extensively adopted in engineering fields including aerospace, energy, transportation, etc. However, the hostile and corrosive environment leaves them vulnerable to external corrosion which poses a severe threat to structural integrity of pipes. Therefore, it is imperative to nondestructively detect and evaluate the external corrosion in nonmagnetic pipes. In light of this, a capsule-type Electromagnetic Acoustic Transducer (EMAT) for in-situ nondestructive evaluation of nonmagnetic pipes and fast screening of external corrosion is proposed in this paper. A 3D hybrid model for efficient prediction of responses from the proposed transducer to external corrosion is established. Closed-form expressions of field quantities of electromagnetics and EMAT signals are formulated. Simulations based on the hybrid model indicate feasibility of the proposed transducer in detection and evaluation of external corrosion in nonmagnetic pipes. In parallel, experiments with the fabricated transducer have been carried out. Experimental results are supportive of the conclusion drawn from simulations. The investigation via simulations and experiments implies that the proposed capsule-type EMAT is capable of fast screening of external corrosion, which is beneficial to the in-situ nondestructive evaluation of small-diameter nonmagnetic pipes.

  3. Effect of pigment concentration on fastness and color values of thermal and UV curable pigment printing

    NASA Astrophysics Data System (ADS)

    Baysal, Gulcin; Kalav, Berdan; Karagüzel Kayaoğlu, Burçak

    2017-10-01

    In the current study, it is aimed to determine the effect of pigment concentration on fastness and colour values of thermal and ultraviolet (UV) curable pigment printing on synthetic leather. For this purpose, thermal curable solvent-based and UV curable water-based formulations were prepared with different pigment concentrations (3, 5 and 7%) separately and applied by screen printing technique using a screen printing machine. Samples printed with solvent-based formulations were thermally cured and samples printed with water-based formulations were cured using a UV curing machine equipped with gallium and mercury (Ga/Hg) lamps at room temperature. The crock fastness values of samples printed with solvent-based formulations showed that increase in pigment concentration was not effective on both dry and wet crock fastness values. On the other hand, in samples printed with UV curable water-based formulations, dry crock fastness was improved and evaluated as very good for all pigment concentrations. However, increasing the pigment concentration affected the wet crock fastness values adversely and lower values were observed. As the energy level increased for each irradiation source, the fastness values were improved. In comparison with samples printed with solvent-based formulations, samples printed with UV curable water-based formulations yielded higher K/S values at all pigment concentrations. The results suggested that, higher K/S values can be obtained in samples printed with UV curable water-based formulations at a lower pigment concentration compared to samples printed with solvent-based formulations.

  4. AutoClickChem: click chemistry in silico.

    PubMed

    Durrant, Jacob D; McCammon, J Andrew

    2012-01-01

    Academic researchers and many in industry often lack the financial resources available to scientists working in "big pharma." High costs include those associated with high-throughput screening and chemical synthesis. In order to address these challenges, many researchers have in part turned to alternate methodologies. Virtual screening, for example, often substitutes for high-throughput screening, and click chemistry ensures that chemical synthesis is fast, cheap, and comparatively easy. Though both in silico screening and click chemistry seek to make drug discovery more feasible, it is not yet routine to couple these two methodologies. We here present a novel computer algorithm, called AutoClickChem, capable of performing many click-chemistry reactions in silico. AutoClickChem can be used to produce large combinatorial libraries of compound models for use in virtual screens. As the compounds of these libraries are constructed according to the reactions of click chemistry, they can be easily synthesized for subsequent testing in biochemical assays. Additionally, in silico modeling of click-chemistry products may prove useful in rational drug design and drug optimization. AutoClickChem is based on the pymolecule toolbox, a framework that may facilitate the development of future python-based programs that require the manipulation of molecular models. Both the pymolecule toolbox and AutoClickChem are released under the GNU General Public License version 3 and are available for download from http://autoclickchem.ucsd.edu.

  5. AutoClickChem: Click Chemistry in Silico

    PubMed Central

    Durrant, Jacob D.; McCammon, J. Andrew

    2012-01-01

    Academic researchers and many in industry often lack the financial resources available to scientists working in “big pharma.” High costs include those associated with high-throughput screening and chemical synthesis. In order to address these challenges, many researchers have in part turned to alternate methodologies. Virtual screening, for example, often substitutes for high-throughput screening, and click chemistry ensures that chemical synthesis is fast, cheap, and comparatively easy. Though both in silico screening and click chemistry seek to make drug discovery more feasible, it is not yet routine to couple these two methodologies. We here present a novel computer algorithm, called AutoClickChem, capable of performing many click-chemistry reactions in silico. AutoClickChem can be used to produce large combinatorial libraries of compound models for use in virtual screens. As the compounds of these libraries are constructed according to the reactions of click chemistry, they can be easily synthesized for subsequent testing in biochemical assays. Additionally, in silico modeling of click-chemistry products may prove useful in rational drug design and drug optimization. AutoClickChem is based on the pymolecule toolbox, a framework that may facilitate the development of future python-based programs that require the manipulation of molecular models. Both the pymolecule toolbox and AutoClickChem are released under the GNU General Public License version 3 and are available for download from http://autoclickchem.ucsd.edu. PMID:22438795

  6. Integrated in silico strategy for PBT assessment and prioritization under REACH.

    PubMed

    Pizzo, Fabiola; Lombardo, Anna; Manganaro, Alberto; Cappelli, Claudia I; Petoumenou, Maria I; Albanese, Federica; Roncaglioni, Alessandra; Brandt, Marc; Benfenati, Emilio

    2016-11-01

    Chemicals may persist in the environment, bioaccumulate and be toxic for humans and wildlife, posing great concern. These three properties, persistence (P), bioaccumulation (B), and toxicity (T) are the key targets of the PBT-hazard assessment. The European regulation for the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires assessment of PBT-properties for all chemicals that are produced or imported in Europe in amounts exceeding 10 tonnes per year, checking whether the criteria set out in REACH Annex XIII are met, so the substance should therefore be considered to have properties of very high concern. Considering how many substances can fall under the REACH regulation, there is a pressing need for new strategies to identify and screen large numbers fast and inexpensively. An efficient non-testing screening approach to identify PBT candidates is necessary, as a valuable alternative to money- and time-consuming laboratory tests and a good start for prioritization since few tools exist (e.g. the PBT profiler developed by US EPA). The aim of this work was to offer a conceptual scheme for identifying and prioritizing chemicals for further assessment and if appropriate further testing, based on their PBT-potential, using a non-testing screening approach. We integrated in silico models (using existing and developing new ones) in a final algorithm for screening and ranking PBT-potential, which uses experimental and predicted values as well as associated uncertainties. The Multi-Criteria Decision-Making (MCDM) theory was used to integrate the different values. Then we compiled a new set of data containing known PBT and non-PBT substances, in order to check how well our approach clearly differentiated compounds labeled as PBT from those labeled as non-PBT. This indicated that the integrated model distinguished between PBT from non-PBT compounds. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Children, adolescents, obesity, and the media.

    PubMed

    Strasburger, Victor C

    2011-07-01

    Obesity has become a worldwide public health problem. Considerable research has shown that the media contribute to the development of child and adolescent obesity, although the exact mechanism remains unclear. Screen time may displace more active pursuits, advertising of junk food and fast food increases children's requests for those particular foods and products, snacking increases while watching TV or movies, and late-night screen time may interfere with getting adequate amounts of sleep, which is a known risk factor for obesity. Sufficient evidence exists to warrant a ban on junk-food or fast-food advertising in children's TV programming. Pediatricians need to ask 2 questions about media use at every well-child or well-adolescent visit: (1) How much screen time is being spent per day? and (2) Is there a TV set or Internet connection in the child's bedroom? Copyright © 2011 by the American Academy of Pediatrics.

  8. Fast Estimation of Dietary Fiber Content in Apple.

    PubMed

    Le Gall, Sophie; Even, Sonia; Lahaye, Marc

    2016-02-17

    Dietary fibers (DF) are one of the nutritional benefits of fleshy fruit consumption that is becoming a quality criterion for genetic selection by breeders. However, the AOAC total DF content determination is not readily amenable for screening large fruit collections. A new screening method of DF content in an apple collection based on the automated preparation of cell wall material as an alcohol-insoluble residue (AIR) is proposed. The yield of AIR from 27 apple genotypes was compared with DF measured according to AOAC method 985.29. Although residual protein content in AIRs did not affect DF measurement, subtraction of starch content above 3% dry weight in AIRs was needed to agree with AOAC measured DF. A fast colorimetric screening of starch in AIR was developed to detect samples needing correction. The proposed method may prove useful for the rapid determination of DF in collections of other fleshy fruit besides apple.

  9. Hazard assessment of exhaust emissions - The next generation of fast and reliable tools for in vitro screening

    NASA Astrophysics Data System (ADS)

    Rothen-Rutishauser, B.

    2017-12-01

    Hazard assessment of exhaust emissions - The next generation of fast and reliable tools for in vitro screening Barbara Rothen-Rutishauser Adolphe Merkle Institute, University of Fribourg, Switzerland; barbara.rothen@unifr.ch Pollution by vehicles is a major problem for the environment due to the various components in the exhaust gasses that are emitted into the atmosphere. A large number of epidemiological studies demonstrate the profound impact of vehicle emissions upon human health [1-3]. Such studies however, are unable to attribute a given subset of emissions to a certain adverse effect, which renders decision making difficult. Standardized protocols for exhaust toxicity assessment are lacking and it relies in many aspects on epidemiological and in vivo studies (animals), which are very time and cost-intensive and suffer from considerable ethical issues. An overview about the current state of research and clinical aspects in the field, as well as about the development of sophisticated in vitro approaches mimicking the inhalation of airborne particles / exhaust for the toxicological testing of engine emissions will be provided. Data will be presented that show that the combination of an air-liquid exposure system and 3D lung-cell culture model offers an adequate tool for fast and reliable investigations of complete exhaust toxicity as well as the effects of particulate fraction [4,5]. This approach yields important results for novel and improved emission technologies in the early stages of product development. [1] Donaldson et al. Part Fibre Toxicol 2005, 2: 10. [2] Ghio et al. J Toxicol Environ Health B Crit Rev 2012, 15: 1-21. [3] Peters et al. Res Rep Health Eff Inst 2009, 5-77. [4] Bisig et al. Emiss Control Sci Technol 2015, 1: 237-246. [5] Steiner et al. Atmos Environ 2013, 81: 380-388.

  10. Global sensitivity analysis for urban water quality modelling: Terminology, convergence and comparison of different methods

    NASA Astrophysics Data System (ADS)

    Vanrolleghem, Peter A.; Mannina, Giorgio; Cosenza, Alida; Neumann, Marc B.

    2015-03-01

    Sensitivity analysis represents an important step in improving the understanding and use of environmental models. Indeed, by means of global sensitivity analysis (GSA), modellers may identify both important (factor prioritisation) and non-influential (factor fixing) model factors. No general rule has yet been defined for verifying the convergence of the GSA methods. In order to fill this gap this paper presents a convergence analysis of three widely used GSA methods (SRC, Extended FAST and Morris screening) for an urban drainage stormwater quality-quantity model. After the convergence was achieved the results of each method were compared. In particular, a discussion on peculiarities, applicability, and reliability of the three methods is presented. Moreover, a graphical Venn diagram based classification scheme and a precise terminology for better identifying important, interacting and non-influential factors for each method is proposed. In terms of convergence, it was shown that sensitivity indices related to factors of the quantity model achieve convergence faster. Results for the Morris screening method deviated considerably from the other methods. Factors related to the quality model require a much higher number of simulations than the number suggested in literature for achieving convergence with this method. In fact, the results have shown that the term "screening" is improperly used as the method may exclude important factors from further analysis. Moreover, for the presented application the convergence analysis shows more stable sensitivity coefficients for the Extended-FAST method compared to SRC and Morris screening. Substantial agreement in terms of factor fixing was found between the Morris screening and Extended FAST methods. In general, the water quality related factors exhibited more important interactions than factors related to water quantity. Furthermore, in contrast to water quantity model outputs, water quality model outputs were found to be characterised by high non-linearity.

  11. A fast stimulability screening protocol for neuronal cultures on microelectrode arrays.

    PubMed

    Kapucu, Fikret E; Tanskanen, Jarno M A; Yuan, Yuting; Hyttinen, Jari A K

    2015-01-01

    Microelectrode arrays (MEAs) are used to study the electrical activity in brain slices and neuronal cultures. MEA experiments for the analysis of electrical stimulation responses require the tissue or culture to be prone to stimulation. For brain slices, potential stimulation sites may be directly visible in microscope, in which case the determination of stimulability at those locations is sufficient. In unstructured neuronal cultures, potential stimulation sites may not be known a priori, and spatial stimulability screening should be performed. Considering, e.g., 59 microelectrode sites, each to be stimulated several times, may result in long screening times, unacceptable with a MEA system without an integrated CO2 incubator, or in high stimulation effects on the networks. Here, we describe an implementation of a fast stimulation protocol employing pseudorandom stimulation site switching aiming at alleviating the network effects of the stimulability screening. In this paper, we show the usability of the proposed protocol by first detecting stimulable locations and subsequently apply repeated stimulation on the identified potentially stimulable locations to observe an exemplary neuronal pathway.

  12. FAITH – Fast Assembly Inhibitor Test for HIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less

  13. Insufficient sensitivity of hemoglobin A(₁C) determination in diagnosis or screening of early diabetic states.

    PubMed

    Fajans, Stefan S; Herman, William H; Oral, Elif A

    2011-01-01

    An International Expert Committee made recommendations for using the hemoglobin A(₁C) (A1C) assay as the preferred method for the diagnosis of diabetes in nonpregnant individuals. A concentration of at least 6.5% was considered as diagnostic. It is the aim of this study to compare the sensitivity of A1C with that of plasma glucose concentrations in subjects with early diabetes or impaired glucose tolerance (IGT). We chose 2 groups of subjects who had A1C not exceeding 6.4%. The first group of 89 subjects had family histories of diabetes (MODY or type 2 diabetes mellitus) and had oral glucose tolerance test (OGTT) and A1C determinations. They included 36 subjects with diabetes or IGT and 53 with normal OGTT. The second group of 58 subjects was screened for diabetes in our Diabetes Clinic by fasting plasma glucose, 2-hour plasma glucose, or OGTT and A1C; and similar comparisons were made. Subjects with diabetes or IGT, including those with fasting hyperglycemia, had A1C ranging from 5.0% to 6.4% (mean, 5.8%). The subjects with normal OGTT had A1C of 4.2% to 6.3% (mean, 5.4%), or 5.5% for the 2 groups. The A1C may be in the normal range in subjects with diabetes or IGT, including those with fasting hyperglycemia. Approximately one third of subjects with early diabetes and IGT have A1C less than 5.7%, the cut point that the American Diabetes Association recommends as indicating the onset of risk of developing diabetes in the future. The results of our study are similar to those obtained by a large Dutch epidemiologic study. If our aim is to recognize early diabetic states to apply effective prophylactic procedures to prevent or delay progression to more severe diabetes, A1C is not sufficiently sensitive or reliable for diagnosis of diabetes or IGT. A combination of A1C and plasma glucose determinations, where necessary, is recommended for diagnosis or screening of diabetes or IGT. Published by Elsevier Inc.

  14. Application of 3D Zernike descriptors to shape-based ligand similarity searching.

    PubMed

    Venkatraman, Vishwesh; Chakravarthy, Padmasini Ramji; Kihara, Daisuke

    2009-12-17

    The identification of promising drug leads from a large database of compounds is an important step in the preliminary stages of drug design. Although shape is known to play a key role in the molecular recognition process, its application to virtual screening poses significant hurdles both in terms of the encoding scheme and speed. In this study, we have examined the efficacy of the alignment independent three-dimensional Zernike descriptor (3DZD) for fast shape based similarity searching. Performance of this approach was compared with several other methods including the statistical moments based ultrafast shape recognition scheme (USR) and SIMCOMP, a graph matching algorithm that compares atom environments. Three benchmark datasets are used to thoroughly test the methods in terms of their ability for molecular classification, retrieval rate, and performance under the situation that simulates actual virtual screening tasks over a large pharmaceutical database. The 3DZD performed better than or comparable to the other methods examined, depending on the datasets and evaluation metrics used. Reasons for the success and the failure of the shape based methods for specific cases are investigated. Based on the results for the three datasets, general conclusions are drawn with regard to their efficiency and applicability. The 3DZD has unique ability for fast comparison of three-dimensional shape of compounds. Examples analyzed illustrate the advantages and the room for improvements for the 3DZD.

  15. Application of 3D Zernike descriptors to shape-based ligand similarity searching

    PubMed Central

    2009-01-01

    Background The identification of promising drug leads from a large database of compounds is an important step in the preliminary stages of drug design. Although shape is known to play a key role in the molecular recognition process, its application to virtual screening poses significant hurdles both in terms of the encoding scheme and speed. Results In this study, we have examined the efficacy of the alignment independent three-dimensional Zernike descriptor (3DZD) for fast shape based similarity searching. Performance of this approach was compared with several other methods including the statistical moments based ultrafast shape recognition scheme (USR) and SIMCOMP, a graph matching algorithm that compares atom environments. Three benchmark datasets are used to thoroughly test the methods in terms of their ability for molecular classification, retrieval rate, and performance under the situation that simulates actual virtual screening tasks over a large pharmaceutical database. The 3DZD performed better than or comparable to the other methods examined, depending on the datasets and evaluation metrics used. Reasons for the success and the failure of the shape based methods for specific cases are investigated. Based on the results for the three datasets, general conclusions are drawn with regard to their efficiency and applicability. Conclusion The 3DZD has unique ability for fast comparison of three-dimensional shape of compounds. Examples analyzed illustrate the advantages and the room for improvements for the 3DZD. PMID:20150998

  16. Field Assessment Stroke Triage for Emergency Destination: A Simple and Accurate Prehospital Scale to Detect Large Vessel Occlusion Strokes.

    PubMed

    Lima, Fabricio O; Silva, Gisele S; Furie, Karen L; Frankel, Michael R; Lev, Michael H; Camargo, Érica C S; Haussen, Diogo C; Singhal, Aneesh B; Koroshetz, Walter J; Smith, Wade S; Nogueira, Raul G

    2016-08-01

    Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED) scale was based on items of the National Institutes of Health Stroke Scale (NIHSS) with higher predictive value for LVOS and tested in the Screening Technology and Outcomes Project in Stroke (STOPStroke) cohort, in which patients underwent computed tomographic angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial internal carotid artery, middle cerebral artery-M1, middle cerebral artery-2, or basilar arteries. Patients with partial, bihemispheric, and anterior+posterior circulation occlusions were excluded. Receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value of FAST-ED were compared with the NIHSS, Rapid Arterial Occlusion Evaluation (RACE) scale, and Cincinnati Prehospital Stroke Severity (CPSS) scale. LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the receiver operating characteristic curve: FAST-ED=0.81 as reference; NIHSS=0.80, P=0.28; RACE=0.77, P=0.02; and CPSS=0.75, P=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity of 0.89, positive predictive value of 0.72, and negative predictive value of 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, and 0.79, and CPSS ≥2 of 0.56, 0.85, 0.65, and 0.78, respectively. FAST-ED is a simple scale that if successfully validated in the field, it may be used by medical emergency professionals to identify LVOS in the prehospital setting enabling rapid triage of patients. © 2016 American Heart Association, Inc.

  17. Starting the Conversation - A Childhood Obesity Knowledge Project Using an App.

    PubMed

    Appel, Hoa B; Huang, Bu; Cole, Allison; James, Rosalina; Ai, Amy L

    2014-04-01

    Starting the Conversation was a pilot project to test an intervention for childhood obesity, a major public health epidemic, using a free smartphone application (app). The primary aim was to assess students' knowledge of nutritional indicators, physical exercise and use of screen time before and after the intervention. The study was conducted in 2011-2012. The sample, recruited from seven high schools in Snohomish County, Washington, was 65.3% minority participants. Of the 118 participants in the sample (n=118), 79 handwrote their responses (n=78) and 36 responded via the app (n=39). We compared the frequency and types of physical exercise, frequency of screen time, and nutritional variables of high school students. Participants used the cell phone app or a handwritten log to record their daily entries for 20 days. Both males (n=43) and females (n=75) grades 9-12 used the app or handwritten entries. Participants who used the app ate less fast food and exercised more, as compared with those who recorded their entries by hand. Screen time usage decreased over the course of the study, based on a comparison of the post-survey level and the pre-survey level. Knowledge of recommended daily consumption of vegetables increased post-test in the app group and knowledge of water consumption increased significantly in both groups. There was no significant difference in BMI pre and post-test. Patterns of nutritional intake, physical exercise and knowledge of these issues varied pre and post-test. It is critical to further examine factors associated with lack of physical activity and food intake patterns of youth using social media to further address the childhood obesity epidemic. Future research should focus on specific ethnic subgroups and an intervention at the school level aimed at the students with BMI ≥ 95 th percentile.

  18. Adaptive Chroma Subsampling-binding and Luma-guided Chroma Reconstruction Method for Screen Content Images.

    PubMed

    Chung, Kuo-Liang; Huang, Chi-Chao; Hsu, Tsu-Chun

    2017-09-04

    In this paper, we propose a novel adaptive chroma subsampling-binding and luma-guided (ASBLG) chroma reconstruction method for screen content images (SCIs). After receiving the decoded luma and subsampled chroma image from the decoder, a fast winner-first voting strategy is proposed to identify the used chroma subsampling scheme prior to compression. Then, the decoded luma image is subsampled as the identified subsampling scheme was performed on the chroma image such that we are able to conclude an accurate correlation between the subsampled decoded luma image and the decoded subsampled chroma image. Accordingly, an adaptive sliding window-based and luma-guided chroma reconstruction method is proposed. The related computational complexity analysis is also provided. We take two quality metrics, the color peak signal-to-noise ratio (CPSNR) of the reconstructed chroma images and SCIs and the gradient-based structure similarity index (CGSS) of the reconstructed SCIs to evaluate the quality performance. Let the proposed chroma reconstruction method be denoted as 'ASBLG'. Based on 26 typical test SCIs and 6 JCT-VC test screen content video sequences (SCVs), several experiments show that on average, the CPSNR gains of all the reconstructed UV images by 4:2:0(A)-ASBLG, SCIs by 4:2:0(MPEG-B)-ASBLG, and SCVs by 4:2:0(A)-ASBLG are 2.1 dB, 1.87 dB, and 1.87 dB, respectively, when compared with that of the other combinations. Specifically, in terms of CPSNR and CGSS, CSBILINEAR-ASBLG for the test SCIs and CSBICUBIC-ASBLG for the test SCVs outperform the existing state-of-the-art comparative combinations, where CSBILINEAR and CSBICUBIC denote the luma-aware based chroma subsampling schemes by Wang et al.

  19. Catalytic fast pyrolysis of white oak wood in-situ using a bubbling fluidized bed reactor

    USDA-ARS?s Scientific Manuscript database

    Catalytic fast pyrolysis was performed on white oak wood using two zeolite-type catalysts as bed material in a bubbling fluidized bed reactor. The two catalysts chosen, based on a previous screening study, were Ca2+ exchanged Y54 (Ca-Y54) and a proprietary ß-zeolite type catalyst (catalyst M) both ...

  20. Automated two-point dixon screening for the evaluation of hepatic steatosis and siderosis: comparison with R2-relaxometry and chemical shift-based sequences.

    PubMed

    Henninger, B; Zoller, H; Rauch, S; Schocke, M; Kannengiesser, S; Zhong, X; Reiter, G; Jaschke, W; Kremser, C

    2015-05-01

    To evaluate the automated two-point Dixon screening sequence for the detection and estimated quantification of hepatic iron and fat compared with standard sequences as a reference. One hundred and two patients with suspected diffuse liver disease were included in this prospective study. The following MRI protocol was used: 3D-T1-weighted opposed- and in-phase gradient echo with two-point Dixon reconstruction and dual-ratio signal discrimination algorithm ("screening" sequence); fat-saturated, multi-gradient-echo sequence with 12 echoes; gradient-echo T1 FLASH opposed- and in-phase. Bland-Altman plots were generated and correlation coefficients were calculated to compare the sequences. The screening sequence diagnosed fat in 33, iron in 35 and a combination of both in 4 patients. Correlation between R2* values of the screening sequence and the standard relaxometry was excellent (r = 0.988). A slightly lower correlation (r = 0.978) was found between the fat fraction of the screening sequence and the standard sequence. Bland-Altman revealed systematically lower R2* values obtained from the screening sequence and higher fat fraction values obtained with the standard sequence with a rather high variability in agreement. The screening sequence is a promising method with fast diagnosis of the predominant liver disease. It is capable of estimating the amount of hepatic fat and iron comparable to standard methods. • MRI plays a major role in the clarification of diffuse liver disease. • The screening sequence was introduced for the assessment of diffuse liver disease. • It is a fast and automated algorithm for the evaluation of hepatic iron and fat. • It is capable of estimating the amount of hepatic fat and iron.

  1. [Preparation and Performance of Ultrafast γ-CuI Scintillation Conversion Screen].

    PubMed

    Xia, Ming; Gu, Mu; Liu, Xiao-lin; Liu, Bo; Huang, Shi-ming; Ni, Chen

    2015-04-01

    Micro-columnar structured γ-CuI scintillation conversion screen with columnar diameter in the micrometer and thickness about 17 µm were prepared by thermal evaporation method on quartz substrates with different temperatures. X-ray excited luminescence spectra of the screens show two peaks located at 430 nm and near 700 nm, which correspond to the fast and slow emission components, respectively. The fast one dominated. The intensity of 430 nm peak decreased as the substrate temperature rose from 170 °C to 210 °C. At the same time the intensity of 700 nm band increased. The changes may be attributed to the iodine loss from screen caused by the substrate temperature. The phenomenon of iodine loss was observed by the Rutherford backscattering experiment. The crystal structure of the screens presents (111) preferred orientation, which is independent of the substrate temperature. As the temperature rose to 210 °C, two weak additional peaks of (220) and (420) γ-CuI crystal planes in X-ray diffraction patterns appeared due to the increase in kinetic energy of CuI molecules. The scanning electron microscopy images of the screens showed that the columnar structure was improved when the substrate temperature increased from 170 °C to 190 °C, but it would be degenerated when the temperature continued to rise to 210 °C because of the surface and bulk diffusion effects of the depositing molecules. Finally, the spatial resolution of the γ-CuI scintillation screens was measured by knife-edge method, and they are 4.5, 7.2 and 5.6lp · mm(-1) for the screens prepared at the substrates temperatures of 170, 190 and 210 °C, respectively. The result shows that micro-column structure could improve the spatial resolution of γ-CuI scintillation screen.

  2. The use of a smartphone application for fast lung cancer risk assessment†.

    PubMed

    Szanto, Zalan; Benko, Istvan; Jakab, Laszlo; Szalai, Gabor; Vereczkei, Andras

    2017-06-01

    The overall prognosis of lung cancer is poor: Only every 8 patient survives 5 years after diagnosis. This outcome is partly attributable to late diagnosis. To implement a screening program for early diagnosis, selection of high-risk individuals is essential. Our aim was to construct a personalized lung cancer risk assessment tool using geographic localization to lead the high-risk individuals to the local health care provider. A smartphone application was created for Android and iOS mobile platforms using a risk assessment questionnaire. The software provides immediate classification into low, moderate and high-risk groups. The high-risk group is directed to the nearest screening centre based on GPS location. The complete test data set is recorded on a collection server database for further analysis. The application was downloaded 13 890 times and completed by 89 500 persons over a period of 20 months. The mean age of the tested users was 36.91 years (9-93 years); the majority were men living in an urban area (62.3%). The test was completed by 38 850 active smokers and 26 710 persons who reported having already quit smoking, resulting in 30 072 moderate and 10 740 high-risk users. This free application is an active communication tool for most smartphone owners. It helps those who might need further medical attention. The affected users can be easily connected and localized via the smartphone, which helps recruit individuals into screening programs. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. Prediction of gestational diabetes mellitus in the first trimester: comparison of C-reactive protein, fasting plasma glucose, insulin and insulin sensitivity indices.

    PubMed

    Ozgu-Erdinc, A Seval; Yilmaz, Saynur; Yeral, M Ilkin; Seckin, K Doga; Erkaya, Salim; Danisman, A Nuri

    2015-11-01

    To develop a predictive index based on high sensitivity C-reactive protein (hs-CRP), fasting plasma glucose (FPG) and fasting plasma insulin (FPI) measurements for early diagnosis of gestational diabetes mellitus (GDM). Healthy pregnant women who were screened for GDM during their first antenatal visit were included in this retrospective cohort study. FPG, FPI and serum hs-CRP concentrations were measured between weeks 11 and 14. A two-step glucose challenge test was carried out between gestational weeks 24 and 28. Fasting glucose/insulin ratio (FIGR), Homeostatic Model Assessment Insulin Resistance (HOMA-IR), HOMA-β indices and Quantitative Insulin Sensitivity Check Index (QUICKI) were used to estimate insulin sensitivity and β-cell function. Of the 450 women who were eligible for the study, 49 (11.2%) were diagnosed with GDM at weeks 24-28. The median FPG and hs-CRP levels were higher in the GDM diagnosed women compared to the others. Comparison of accuracy measures resulted in the highest specificity (87.2%; 95% CI 83.5-90.1) and diagnostic odds ratio (3.9; 95% CI 2.1-7.6) for hs-CRP. FPG and hs-CRP in the first trimester are correlated with later development of GDM in the pregnancy. In our study, FPG provided a better sensitivity while hs-CRP exhibited a better specificity for prediction of GDM.

  4. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples.

    PubMed

    Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M

    2012-02-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.

  5. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

    PubMed Central

    Gerace, E.; Salomone, A.; Abbadessa, G.; Racca, S.; Vincenti, M.

    2011-01-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. PMID:29403714

  6. The Premenstrual Symptoms Screening Tool revised for adolescents (PSST-A): prevalence of severe PMS and premenstrual dysphoric disorder in adolescents.

    PubMed

    Steiner, Meir; Peer, Miki; Palova, Eva; Freeman, Ellen W; Macdougall, Mary; Soares, Claudio N

    2011-02-01

    The Premenstrual Symptoms Screening Tool was modified for use in adolescents and piloted in 578 girls at three international sites. Nearly one third (29.6%) reported experiencing severe PMS or PMDD, with irritability being the most commonly reported symptom. Rates of menstrual-related pain were high, particularly in those with severe PMS or PMDD. Severe PMS and PMDD present with similar rates and symptoms in adolescents as in adults, and the Premenstrual Symptoms Screening Tool modified for adolescents is a fast, reliable tool to screen for these syndromes in adolescents.

  7. Human immunodeficiency virus test-seeking blood donors in a large blood bank in São Paulo, Brazil.

    PubMed

    Goncalez, Thelma; Sabino, Ester; Sales, Nanci; Chen, Yea-Hung; Chamone, Dalton; Busch, Michael; Murphy, Edward; Custer, Brian; McFarland, Willi

    2010-08-01

    Persons with human immunodeficiency virus (HIV) risk behaviors are excluded from donation to reduce the risk of transfusion-transmitted infection. Persons donating to be tested for HIV may therefore deny risk behaviors. A random sample of donors completed a survey on motivations, knowledge, and attitudes on the screening process. Donors were considered test seekers if they agreed with two statements "I think that blood donation is a good, fast, and anonymous way to get my blood tested" and "I donate to get my test results." This study was conducted from June to November 2006 at the largest blood bank in São Paulo, Brazil. Of 3061 participants, 208 (7%) were test seekers. They tended to be male and had a lower educational level. They were more likely to have incorrect knowledge about blood safety (e.g., not knowing that a unit can test antibody negative and still transmit infection, 50% vs. 42%, p = 0.02), express dissatisfaction with screening questions (e.g., feeling that important questions were not asked, 14% vs. 5%, p < 0.01), and concur that donors do not answer questions truthfully (e.g., donors have more sexual partners than they admit, 29% vs. 18%, p < 0.01). Test seekers were more likely to believe that it is acceptable to donate blood to get tested for HIV (41% vs. 10%, p < 0.01). Test-seeking motivation, coupled with low knowledge of window period risk, is counter to improving blood safety and to donor prevention needs. Donor education needs to be improved along with availability of appropriate HIV counseling and testing. © 2010 American Association of Blood Banks.

  8. Evaluation of cable tension sensors of FAST reflector from the perspective of EMI

    NASA Astrophysics Data System (ADS)

    Zhu, Ming; Wang, Qiming; Egan, Dennis; Wu, Mingchang; Sun, Xiao

    2016-06-01

    The active reflector of FAST (five-hundred-meter aperture spherical radio telescope) is supported by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time paraboloids. To ensure the security and stability of the supporting structure, tension must be monitored for some typical cables. Considering the stringent requirements in accuracy and long-term stability, magnetic flux sensor, vibrating wire strain gauge and fiber bragg grating strain gauge are screened for the cable tension monitoring of the supporting cable-net. Specifically, receivers of radio telescopes have strict restriction on electro magnetic interference (EMI) or radio frequency interference (RFI). These three types of sensors are evaluated from the view of EMI/RFI. Firstly, these fundamentals are theoretically analyzed. Secondly, typical sensor signals are collected in the time and analyzed in the frequency domain, which shows the characteristic in the frequency domain. Finally, typical sensors are tested in an anechoic chamber to get the EMI levels. Theoretical analysis shows that Fiber Bragg Grating strain gauge itself will not lead to EMI/RFI. According to GJB151A, frequency domain analysis and test results show that for the vibrating wire strain gauge and magnetic flux sensor themselves, testable EMI/RFI levels are typically below the background noise of the anechoic chamber. FAST finally choses these three sensors as the monitoring sensors of its cable tension. The proposed study is also a reference to the monitoring equipment selection of other radio telescopes and large structures.

  9. Screening for Fall Risks in the Emergency Department: A Novel Nursing-Driven Program.

    PubMed

    Huded, Jill M; Dresden, Scott M; Gravenor, Stephanie J; Rowe, Theresa; Lindquist, Lee A

    2015-12-01

    Seniors represent the fasting growing population in the U.S., accounting for 20.3 million visits to emergency departments (EDs) annually. The ED visit can provide an opportunity for identifying seniors at high risk of falls. We sought to incorporate the Timed Up & Go Test (TUGT), a commonly used falls screening tool, into the ED encounter to identify seniors at high fall risk and prompt interventions through a geriatric nurse liaison (GNL) model. Patients aged 65 and older presenting to an urban ED were evaluated by a team of ED nurses trained in care coordination and geriatric assessment skills. They performed fall risk screening with the TUGT. Patients with abnormal TUGT results could then be referred to physical therapy (PT), social work or home health as determined by the GNL. Gait assessment with the TUGT was performed on 443 elderly patients between 4/1/13 and 5/31/14. A prior fall was reported in 37% of patients in the previous six months. Of those screened with the TUGT, 368 patients experienced a positive result. Interventions for positive results included ED-based PT (n=63, 17.1%), outpatient PT referrals (n=56, 12.2%) and social work consultation (n=162, 44%). The ED visit may provide an opportunity for older adults to be screened for fall risk. Our results show ED nurses can conduct the TUGT, a validated and time efficient screen, and place appropriate referrals based on assessment results. Identifying and intervening on high fall risk patients who visit the ED has the potential to improve the trajectory of functional decline in our elderly population.

  10. Refolding strategies from inclusion bodies in a structural genomics project.

    PubMed

    Trésaugues, Lionel; Collinet, Bruno; Minard, Philippe; Henckes, Gilles; Aufrère, Robert; Blondeau, Karine; Liger, Dominique; Zhou, Cong-Zhao; Janin, Joël; Van Tilbeurgh, Herman; Quevillon-Cheruel, Sophie

    2004-01-01

    The South-Paris Yeast Structural Genomics Project aims at systematically expressing, purifying and determining the structure of S. cerevisiae proteins with no detectable homology to proteins of known structure. We brought 250 yeast ORFs to expression in E. coli, but 37% of them form inclusion bodies. This important fraction of proteins that are well expressed but lost for structural studies prompted us to test methodologies to recover these proteins. Three different strategies were explored in parallel on a set of 20 proteins: (1) refolding from solubilized inclusion bodies using an original and fast 96-well plates screening test, (2) co-expression of the targets in E. coli with DnaK-DnaJ-GrpE and GroEL-GroES chaperones, and (3) use of the cell-free expression system. Most of the tested proteins (17/20) could be resolubilized at least by one approach, but the subsequent purification proved to be difficult for most of them.

  11. Insulation bonding test system

    NASA Technical Reports Server (NTRS)

    Beggs, J. M.; Johnston, G. D.; Coleman, A. D.; Portwood, J. N.; Saunders, J. M.; Redmon, J. W.; Porter, A. C. (Inventor)

    1984-01-01

    A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.

  12. The Belgian Diabetes in Pregnancy Study (BEDIP-N), a multi-centric prospective cohort study on screening for diabetes in pregnancy and gestational diabetes: methodology and design

    PubMed Central

    2014-01-01

    Background The International Association of Diabetes and Pregnancy Study Groups (IADPSG) recommends universal screening with a 75 g oral glucose tolerance test (OGTT) using stricter criteria for gestational diabetes (GDM). This may lead to important increases in the prevalence of GDM and associated costs, whereas the gain in health is unclear. The goal of ‘The Belgian Diabetes in Pregnancy Study’ (BEDIP-N) is to evaluate the best screening strategy for pregestational diabetes in early pregnancy and GDM in an ethnically diverse western European population. The IADPSG screening strategy will be followed, but in addition risk questionnaires and a 50 g glucose challenge test (GCT) will be performed, in order to define the most practical and most cost effective screening strategy in this population. Methods BEDIP-N is a prospective observational cohort study in 6 centers in Belgium. The aim is to enroll 2563 pregnant women in the first trimester with a singleton pregnancy, aged 18–45 years, without known diabetes and without history of bariatric surgery. Women are universally screened for overt diabetes and GDM in the first trimester with a fasting plasma glucose and for GDM between 24–28 weeks using the 50 g GCT and independently of the result of the GCT, all women will receive a 75 g OGTT using the IADPSG criteria. Diabetes and GDM will be treated according to a standardized routine care protocol. Women with GDM, will be reevaluated three months postpartum with a 75 g OGTT. At each visit blood samples are collected, anthropometric measurements are obtained and self-administered questionnaires are completed. Recruitment began in April 2014. Discussion This is the first large, prospective cohort study rigorously assessing the prevalence of diabetes in early pregnancy and comparing the impact of different screening strategies with the IADPSG criteria on the detection of GDM later in pregnancy. Trial registration ClinicalTrials.gov: NCT02036619. Registered 14-1-2014. PMID:25015413

  13. Johne's disease: a successful eradication programme in a dairy goat herd.

    PubMed

    Gavin, William G; Porter, Catherine A; Hawkins, Nathan; Schofield, Michael J; Pollock, John M

    2018-04-28

    This retrospective analysis and report describes the successful eradication and posteradication surveillance programme for Johne's disease ( Mycobacterium avium subspecies paratuberculosis (MAP)) in a closed herd of dairy goats. In 1994, MAP's presence in the goat herd was first suspected through individual annual serological screening and then subsequently confirmed through faecal culture and histopathology in 1997 when implementation of a more aggressive programme of testing and eradication of the diseased animals began. This programme included frequent serological screening of all adult goats using ELISA and agar gel immunodiffusion assays. Faecal cultures for bacteria were performed on suspect or positive animals and for all goats found dead or euthanased, and tissues were submitted for histopathology and acid-fast staining. Additional disease eradication measures included maintaining a closed herd and minimising faecal-oral transmission of MAP. Following a more aggressive testing regimen and euthanasia of goats with positive faecal culture, the herd was first considered free of MAP in 2003 and has remained free to the present day. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. A new effective assay to detect antimicrobial activity of filamentous fungi.

    PubMed

    Pereira, Eric; Santos, Ana; Reis, Francisca; Tavares, Rui M; Baptista, Paula; Lino-Neto, Teresa; Almeida-Aguiar, Cristina

    2013-01-15

    The search for new antimicrobial compounds and the optimization of production methods turn the use of antimicrobial susceptibility tests a routine. The most frequently used methods are based on agar diffusion assays or on dilution in agar or broth. For filamentous fungi, the most common antimicrobial activity detection methods comprise the co-culture of two filamentous fungal strains or the use of fungal extracts to test against single-cell microorganisms. Here we report a rapid, effective and reproducible assay to detect fungal antimicrobial activity against single-cell microorganisms. This method allows an easy way of performing a fast antimicrobial screening of actively growing fungi directly against yeast. Because it makes use of an actively growing mycelium, this bioassay also provides a way for studying the production dynamics of antimicrobial compounds by filamentous fungi. The proposed assay is less time consuming and introduces the innovation of allowing the direct detection of fungal antimicrobial properties against single cell microorganisms without the prior isolation of the active substance(s). This is particularly useful when performing large screenings for fungal antimicrobial activity. With this bioassay, antimicrobial activity of Hypholoma fasciculare against yeast species was observed for the first time. Copyright © 2012 Elsevier GmbH. All rights reserved.

  15. Functional parameter screening for predicting durability of rolling sliding contacts with different surface finishes

    NASA Astrophysics Data System (ADS)

    Dimkovski, Z.; Lööf, P.-J.; Rosén, B.-G.; Nilsson, P. H.

    2018-06-01

    The reliability and lifetime of machine elements such as gears and rolling bearings depend on their wear and fatigue resistance. In order to screen the wear and surface damage, three finishing processes: (i) brushing, (ii) manganese phosphating and (iii) shot peening were applied on three disc pairs and long-term tested on a twin-disc tribometer. In this paper, the elastic contact of the disc surfaces (measured after only few revolutions) was simulated and a number of functional and roughness parameters were correlated. The functional parameters consisted of subsurface stresses at different depths and a new parameter called ‘pressure spikes’ factor’. The new parameter is derived from the pressure distribution and takes into account the proximity and magnitude of the pressure spikes. Strong correlations were found among the pressure spikes’ factor and surface peak/height parameters. The orthogonal shear stresses and Von Mises stresses at the shallowest depths under the surface have shown the highest correlations but no good correlations were found when the statistics of the whole stress fields was analyzed. The use of the new parameter offers a fast way to screen the durability of the contacting surfaces operating at similar conditions.

  16. Ultrahigh-speed X-ray imaging of hypervelocity projectiles

    NASA Astrophysics Data System (ADS)

    Miller, Stuart; Singh, Bipin; Cool, Steven; Entine, Gerald; Campbell, Larry; Bishel, Ron; Rushing, Rick; Nagarkar, Vivek V.

    2011-08-01

    High-speed X-ray imaging is an extremely important modality for healthcare, industrial, military and research applications such as medical computed tomography, non-destructive testing, imaging in-flight projectiles, characterizing exploding ordnance, and analyzing ballistic impacts. We report on the development of a modular, ultrahigh-speed, high-resolution digital X-ray imaging system with large active imaging area and microsecond time resolution, capable of acquiring at a rate of up to 150,000 frames per second. The system is based on a high-resolution, high-efficiency, and fast-decay scintillator screen optically coupled to an ultra-fast image-intensified CCD camera designed for ballistic impact studies and hypervelocity projectile imaging. A specially designed multi-anode, high-fluence X-ray source with 50 ns pulse duration provides a sequence of blur-free images of hypervelocity projectiles traveling at speeds exceeding 8 km/s (18,000 miles/h). This paper will discuss the design, performance, and high frame rate imaging capability of the system.

  17. Automated combinatorial method for fast and robust prediction of lattice thermal conductivity

    NASA Astrophysics Data System (ADS)

    Plata, Jose J.; Nath, Pinku; Usanmaz, Demet; Toher, Cormac; Fornari, Marco; Buongiorno Nardelli, Marco; Curtarolo, Stefano

    The lack of computationally inexpensive and accurate ab-initio based methodologies to predict lattice thermal conductivity, κl, without computing the anharmonic force constants or performing time-consuming ab-initio molecular dynamics, is one of the obstacles preventing the accelerated discovery of new high or low thermal conductivity materials. The Slack equation is the best alternative to other more expensive methodologies but is highly dependent on two variables: the acoustic Debye temperature, θa, and the Grüneisen parameter, γ. Furthermore, different definitions can be used for these two quantities depending on the model or approximation. Here, we present a combinatorial approach based on the quasi-harmonic approximation to elucidate which definitions of both variables produce the best predictions of κl. A set of 42 compounds was used to test accuracy and robustness of all possible combinations. This approach is ideal for obtaining more accurate values than fast screening models based on the Debye model, while being significantly less expensive than methodologies that solve the Boltzmann transport equation.

  18. Prevalence of diabetes, impaired fasting glucose and associated risk factors in a rural area of Baluchistan province according to new ADA criteria.

    PubMed

    Basit, A; Hydrie, M Z I; Ahmed, K; Hakeem, R

    2002-08-01

    To assess the prevalence of impaired fasting glucose (IFG) and diabetes in an adult rural population on the basis of fasting blood glucose (FBG) alone using American Diabetic Association (ADA) criteria and to assess the prevalence of and association between selected risk factors such as obesity, family history of diabetes and hypertension. Sixteen randomly selected villages from the Lasbella district of Baluchistan were included in this study. One month before the survey a team visited the areas; all the households located in the selected areas were approached and the family members aged 25 or above, who were available and willing to participate in the study, were recruited. On the day of survey anthroprometric and blood pressure measurements were taken; interviews were conducted to obtain demographic information and health history and fasting blood samples were collected. The blood samples were transported to the laboratory and analysed using "GOD-PAP" Enzymatic Colorimetric test method. A total of 670 males and 1362 females were studied. Prevalence rate of diabetes using the ADA fasting criteria was 6.3% while the prevalence rate in males was 10.1% and in females was 4.3%. The prevalence rate of impaired fasting glucose was 4.2% in males and 2.3% in females. Overall prevalence of obesity between diabetics vs non-diabetics was 22% vs 16%, for hypertension 12.9% vs 6.5% and for positive family history of diabetes 1.6% vs 0.9% was higher among diabetics as compared to non diabetics; the difference of these parameters was statistically significant only among females (P < 0.01). The results of this study suggest the need of continual use of OGTT for screening people at high risk of developing diabetes and perhaps also for diagnosing diabetes.

  19. Particle size and shape distributions of hammer milled pine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westover, Tyler Lott; Matthews, Austin Colter; Williams, Christopher Luke

    2015-04-01

    Particle size and shape distributions impact particle heating rates and diffusion of volatized gases out of particles during fast pyrolysis conversion, and consequently must be modeled accurately in order for computational pyrolysis models to produce reliable results for bulk solid materials. For this milestone, lodge pole pine chips were ground using a Thomas-Wiley #4 mill using two screen sizes in order to produce two representative materials that are suitable for fast pyrolysis. For the first material, a 6 mm screen was employed in the mill and for the second material, a 3 mm screen was employed in the mill. Bothmore » materials were subjected to RoTap sieve analysis, and the distributions of the particle sizes and shapes were determined using digital image analysis. The results of the physical analysis will be fed into computational pyrolysis simulations to create models of materials with realistic particle size and shape distributions. This milestone was met on schedule.« less

  20. SPLICEFINDER – A Fast and Easy Screening Method for Active Protein Trans-Splicing Positions

    PubMed Central

    Eppmann, Simone; Busche, Alena; Dikovskaya, Dina; Dötsch, Volker; Mootz, Henning D.

    2013-01-01

    Split intein enabled protein trans-splicing (PTS) is a powerful method for the ligation of two protein fragments, thereby paving the way for various protein modification or protein function control applications. PTS activity is strongly influenced by the amino acids directly flanking the splice junctions. However, to date no reliable prediction can be made whether or not a split intein is active in a particular foreign extein context. Here we describe SPLICEFINDER, a PCR-based method, allowing fast and easy screening for active split intein insertions in any target protein. Furthermore we demonstrate the applicability of SPLICEFINDER for segmental isotopic labeling as well as for the generation of multi-domain and enzymatically active proteins. PMID:24023792

  1. Obesity and Insulin Resistance Screening Tools in American Adolescents: National Health and Nutrition Examination Survey (NHANES) 1999 to 2010.

    PubMed

    Lee, Joey A; Laurson, Kelly R

    2016-08-01

    To identify which feasible obesity and insulin resistance (IR) screening tools are most strongly associated in adolescents by using a nationally representative sample. Adolescents aged 12.0 to 18.9 years who were participating in the National Health and Nutrition Examination Survey (NHANES) (n=3584) and who were measured for height, weight, waist circumference (WC), triceps and subscapular skinfold thickness, glycated hemoglobin, fasting glucose (FG) and fasting insulin (FI) level were included. Adolescents were split by gender and grouped by body mass index (BMI) percentile. Age- and gender-specific classifications were constructed for each obesity screening tool measure to account for growth and maturation. General linear models were used to establish groups objectively for analysis based on when IR began to increase. Additional general linear models were used to identify when IR significantly increased for each IR measure as obesity group increased and to identify the variance accounted for among each obesity-IR screening tool relationship. As the obesity group increased, homeostasis model assessment-insulin resistance (HOMA-IR) and FI significantly increased, while FG increased only (above the referent) in groups with BMI percentiles ≥95.0, and glycated hemoglobin level did not vary across obesity groups. The most strongly associated screening tools were WC and FI in boys (R(2)=0.253) and girls (R(2)=0.257). FI had the strongest association with all of the obesity measures. BMI associations were slightly weaker than WC in each in relation to IR. Our findings show that WC and FI are the most strongly associated obesity and IR screening tool measures in adolescents. These feasible screening tools should be utilized in screening practices for at-risk adolescents. Copyright © 2015 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  2. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A comprehensive evaluation of various sensitivity analysis methods: A case study with a hydrological model

    DOE PAGES

    Gan, Yanjun; Duan, Qingyun; Gong, Wei; ...

    2014-01-01

    Sensitivity analysis (SA) is a commonly used approach for identifying important parameters that dominate model behaviors. We use a newly developed software package, a Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), to evaluate the effectiveness and efficiency of ten widely used SA methods, including seven qualitative and three quantitative ones. All SA methods are tested using a variety of sampling techniques to screen out the most sensitive (i.e., important) parameters from the insensitive ones. The Sacramento Soil Moisture Accounting (SAC-SMA) model, which has thirteen tunable parameters, is used for illustration. The South Branch Potomac River basin nearmore » Springfield, West Virginia in the U.S. is chosen as the study area. The key findings from this study are: (1) For qualitative SA methods, Correlation Analysis (CA), Regression Analysis (RA), and Gaussian Process (GP) screening methods are shown to be not effective in this example. Morris One-At-a-Time (MOAT) screening is the most efficient, needing only 280 samples to identify the most important parameters, but it is the least robust method. Multivariate Adaptive Regression Splines (MARS), Delta Test (DT) and Sum-Of-Trees (SOT) screening methods need about 400–600 samples for the same purpose. Monte Carlo (MC), Orthogonal Array (OA) and Orthogonal Array based Latin Hypercube (OALH) are appropriate sampling techniques for them; (2) For quantitative SA methods, at least 2777 samples are needed for Fourier Amplitude Sensitivity Test (FAST) to identity parameter main effect. McKay method needs about 360 samples to evaluate the main effect, more than 1000 samples to assess the two-way interaction effect. OALH and LPτ (LPTAU) sampling techniques are more appropriate for McKay method. For the Sobol' method, the minimum samples needed are 1050 to compute the first-order and total sensitivity indices correctly. These comparisons show that qualitative SA methods are more efficient but less accurate and robust than quantitative ones.« less

  4. Construction and performance characterization of screen printed and carbon paste ion selective electrodes for potentiometric determination of naphazoline hydrochloride in pharmaceutical preparations.

    PubMed

    Frag, Eman Y Z; Mohamed, Gehad G; El-Dien, F A Nour; Mohamed, Marwa E

    2011-01-21

    This paper describes the development of screen-printed (SPE) and carbon paste (CPE) sensors for the rapid and sensitive quantification of naphazoline hydrochloride (NPZ) in pharmaceutical formulations. This work compares the electroactivity of conventional carbon paste and screen-printed carbon paste electrodes towards potentiometric titration of NPZ. The repeatability and accuracy of measurements performed in the analysis of these pharmaceutical matrices using new screen printed sensors were evaluated. The influence of the electrode composition, conditioning time of the electrode and pH of the test solution, on the electrode performance were investigated. The drug electrode showed Nernstain responses in the concentration range from 1 × 10(-6) to 1 × 10(-2) mol L(-1) with slopes of 57.5 ± 1.3 and 55.9 ± 1.6 mV per decade for SPE and CPE, respectively, and was found to be very precise and usable within the pH range 3-8. These sensors exhibited a fast response time (about 3 s for both SPE and CPE, respectively), a low detection limit (3.5 × 10(-6) and 1.5 × 10(-6) M for SPE and CPE, respectively), a long lifetime (3 and 2 months for SPE and CPE, respectively) and good stability. The selectivity of the electrode toward a large number of inorganic cations, sugars and amino acids was tested. It was applied to potentiometric determination of NPZ in pure state and pharmaceutical preparation under batch conditions. The percentage recovery values for the assay of NPZ in tablets (relative standard deviations ≤0.3% for n = 4) were compared well with those obtained by the official method.

  5. Diabetic subjects diagnosed through the Diabetes Prevention Trial-Type 1 (DPT-1) are often asymptomatic with normal A1C at diabetes onset.

    PubMed

    Triolo, Taylor M; Chase, H Peter; Barker, Jennifer M

    2009-05-01

    Upon diagnosis of type 1 diabetes, patients are usually symptomatic, and many have ketoacidosis. Screening for islet autoantibodies (IAs) has been shown to decrease A1C level and rate of hospitalization at diabetes onset. Metabolic tests and the presence of symptoms were described at diabetes onset during the Diabetes Prevention Trial-Type 1 (DPT-1). The DPT-1 screened relatives of patients with type 1 diabetes for islet cell autoantiobodies (ICAs). Those with positive ICAs had intravenous and oral glucose tolerance tests (IVGTTs and OGTTs) and were randomized into one of two prevention trials. Throughout the DPT-1 parenteral and oral insulin study, 246 people were diagnosed with type 1 diabetes. Of the 246 subjects diagnosed with diabetes, 218 had data regarding the presence of symptoms, and 138 (63.3%) reported no symptoms suggestive of diabetes. Eight subjects (3.67%) presented with ketosis. Subjects presented with a mean +/- SD A1C of 6.41 +/- 1.15%. At diagnosis, 90 subjects (50.8%) had A1C in the normal range (<6.2%). OGTT data at the time of diagnosis indicate that 35.4% had a glucose result of <100 mg/dl at 0 min. The majority of subjects diagnosed with type 1 diabetes through the DPT-1 were asymptomatic at onset and had normal fasting glucose and A1C levels. This suggests that intermittent screening (IA followed by OGTT) may allow diagnosis of diabetes before severe metabolic decompensation. Screening with A1C will miss identifying many of the subjects with newly diagnosed type 1 diabetes in this cohort.

  6. Assessment of beating parameters in human induced pluripotent stem cells enables quantitative in vitro screening for cardiotoxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sirenko, Oksana, E-mail: oksana.sirenko@moldev.com; Cromwell, Evan F., E-mail: evan.cromwell@moldev.com; Crittenden, Carole

    2013-12-15

    Human induced pluripotent stem cell (iPSC)-derived cardiomyocytes show promise for screening during early drug development. Here, we tested a hypothesis that in vitro assessment of multiple cardiomyocyte physiological parameters enables predictive and mechanistically-interpretable evaluation of cardiotoxicity in a high-throughput format. Human iPSC-derived cardiomyocytes were exposed for 30 min or 24 h to 131 drugs, positive (107) and negative (24) for in vivo cardiotoxicity, in up to 6 concentrations (3 nM to 30 uM) in 384-well plates. Fast kinetic imaging was used to monitor changes in cardiomyocyte function using intracellular Ca{sup 2+} flux readouts synchronous with beating, and cell viability. Amore » number of physiological parameters of cardiomyocyte beating, such as beat rate, peak shape (amplitude, width, raise, decay, etc.) and regularity were collected using automated data analysis. Concentration–response profiles were evaluated using logistic modeling to derive a benchmark concentration (BMC) point-of-departure value, based on one standard deviation departure from the estimated baseline in vehicle (0.3% dimethyl sulfoxide)-treated cells. BMC values were used for cardiotoxicity classification and ranking of compounds. Beat rate and several peak shape parameters were found to be good predictors, while cell viability had poor classification accuracy. In addition, we applied the Toxicological Prioritization Index (ToxPi) approach to integrate and display data across many collected parameters, to derive “cardiosafety” ranking of tested compounds. Multi-parameter screening of beating profiles allows for cardiotoxicity risk assessment and identification of specific patterns defining mechanism-specific effects. These data and analysis methods may be used widely for compound screening and early safety evaluation in drug development. - Highlights: • Induced pluripotent stem cell-derived cardiomyocytes are promising in vitro models. • We tested if evaluation of cardiotoxicity is possible in a high-throughput format. • The assay shows benefits of automated data integration across multiple parameters. • Quantitative assessment of concentration–response is possible using iPSCs. • Multi-parametric screening allows for cardiotoxicity risk assessment.« less

  7. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma.

    PubMed

    Tummers, W; van Schuppen, J; Langeveld, H; Wilde, J; Banderker, E; van As, A

    2016-06-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical decision-making regarding paediatric BAT. Children presented at the Trauma Unit of the Red Cross War Memorial Children's Hospital, Cape Town, after HET, and underwent both a physical examination and a FAST. The presence of free fluid in the abdomen and pelvis was assessed using a FAST. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) for identifying intraabdominal injury were calculated for the physical examination and the FAST, both individually and when combined. Seventy-five patients were included as per the criteria for HET as follows: pedestrian motor vehicle crashes (MVCs) ( n = 46), assault ( n = 14), fall from a height ( n = 9), MVC passenger ( n = 4) and other ( n = 2). The ages of the patients ranged from 3 months to 13 years. The sensitivity of the physical examination was 0.80, specificity 0.83, PPV 0.42 and NPV 0.96. The sensitivity of the FAST was 0.50, specificity 1.00, PPV 1.00 and NPV 0.93. Sensitivity increased to 0.90 when the physical examination was combined with the FAST. Nonoperative management was used in 73 patients. Two underwent an operation. A FAST should be performed in combination with a physical examination on every paediatric patient involved in HET to detect BAT. When both are negative, nonoperative management can be implemented without fear of missing a clinically significant injury. FAST is a safe, effective and easily accessible alternative to CT, which avoids ionising radiation and aids in clinical decision-making.

  8. Fast Computation and Assessment Methods in Power System Analysis

    NASA Astrophysics Data System (ADS)

    Nagata, Masaki

    Power system analysis is essential for efficient and reliable power system operation and control. Recently, online security assessment system has become of importance, as more efficient use of power networks is eagerly required. In this article, fast power system analysis techniques such as contingency screening, parallel processing and intelligent systems application are briefly surveyed from the view point of their application to online dynamic security assessment.

  9. Attracted by a magnet: Exploration behaviour of rodents in the presence of magnetic objects.

    PubMed

    Malewski, Sandra; Malkemper, E Pascal; Sedláček, František; Šumbera, Radim; Caspar, Kai R; Burda, Hynek; Begall, Sabine

    2018-06-01

    Magnetosensitivity is widespread among animals with rodents being the most intensively studied mammalian group. The available behavioural assays for magnetoreception are time-consuming, which impedes screens for treatment effects that could characterize the enigmatic magnetoreceptors. Here, we present a fast and simple approach to test if an animal responds to magnetic stimuli: the magnetic object assay (MOA). The MOA focuses on investigating an animal's spontaneous exploration behaviour in the presence of a bar magnet compared to a demagnetised control. We present consistently longer exploration of the magnet in three different rodent species: Ansell's mole-rat (Fukomys anselli), C57BL/6J laboratory mouse, and naked mole-rat (Heterocephalus glaber). For the naked mole-rat this is the first report that this species reacts on magnetic stimuli. We conclude that the MOA holds the potential to screen if an animal responds to magnetic stimuli, indicating the possession of a magnetic sense. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. In-situ upgrading of biomass pyrolysis vapors: catalyst screening on a fixed bed reactor.

    PubMed

    Stefanidis, S D; Kalogiannis, K G; Iliopoulou, E F; Lappas, A A; Pilavachi, P A

    2011-09-01

    In-situ catalytic upgrading of biomass fast pyrolysis vapors was performed in a fixed bed bench-scale reactor at 500°C, for catalyst screening purposes. The catalytic materials tested include a commercial equilibrium FCC catalyst (E-cat), various commercial ZSM-5 formulations, magnesium oxide and alumina materials with varying specific surface areas, nickel monoxide, zirconia/titania, tetragonal zirconia, titania and silica alumina. The bio-oil was characterized measuring its water content, the carbon-hydrogen-oxygen (by difference) content and the chemical composition of its organic fraction. Each catalytic material displayed different catalytic effects. High surface area alumina catalysts displayed the highest selectivity towards hydrocarbons, yielding however low organic liquid products. Zirconia/titania exhibited good selectivity towards desired compounds, yielding higher organic liquid product than the alumina catalysts. The ZSM-5 formulation with the highest surface area displayed the most balanced performance having a moderate selectivity towards hydrocarbons, reducing undesirable compounds and producing organic liquid products at acceptable yields. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  12. Direct mass spectrometric screening of antibiotics from bacterial surfaces using liquid extraction surface analysis.

    PubMed

    Kai, Marco; González, Ignacio; Genilloud, Olga; Singh, Sheo B; Svatoš, Aleš

    2012-10-30

    There is a need to find new antibiotic agents to fight resistant pathogenic bacteria. To search successfully for novel antibiotics from bacteria cultivated under diverse conditions, we need a fast and cost-effective screening method. A combination of Liquid Extraction Surface Analysis (LESA), automated chip-based nanoelectrospray ionization, and high-resolution mass or tandem mass spectrometry using an Orbitrap XL was tested as the screening platform. Actinobacteria, known to produce well-recognized thiazolyl peptide antibiotics, were cultivated on a plate of solid medium and the antibiotics were extracted by organic solvent mixtures from the surface of colonies grown on the plate and analyzed using mass spectrometry (MS). LESA combined with high-resolution MS is a powerful tool with which to extract and detect thiazolyl peptide antibiotics from different Actinobacteria. Known antibiotics were correctly detected with high mass accuracy (<4 ppm) and structurally characterized using tandem mass spectra. Our method is the first step toward the development of a novel high-throughput extraction and identification tool for antibiotics in particular and natural products in general. The method described in this paper is suitable for (1) screening the natural products produced by bacterial colonies on cultivation plates within the first 2 min following extraction and (2) detecting antibiotics at high mass accuracy; the cost is around 2 Euro per sample. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Screening of a dust particle charge in a humid air plasma created by an electron beam

    NASA Astrophysics Data System (ADS)

    Filippov, A. V.; Derbenev, I. N.; Kurkin, S. A.

    2018-01-01

    A kinetic model has been developed for charged particle reactions in a humid air plasma produced by a fast electron beam. The model includes over 550 reactions with electrons, 33 positive ion species and 14 negative ion species. The model has been tested by solving 48 non-steady state equations for number densities of charged particles in humid air electron beam plasma, and by comparing with the available experimental data. The system of 48 steady state equations has been solved by iterative method in order to define the main ion species of the humid air plasma. A reduced kinetic model has been developed to describe the processes with the main ions and electrons. Screening constants have been calculated on the basis of the reduced system by means of Leverrier-Fadeev method. The dependencies of screening constants on gas ionization rates have been found for the rates from 10 to 1018 cm-3s-1 and the fraction of water molecules from 0 to 2%. The analysis of the constants has revealed that one of them is close to the inverse Debye length, and the other constants are defined by the inverse diffusion lengths passed by ions in the characteristic times of the attachment, recombination, and ion conversion. Pure imaginary screening constants appear at low rates of gas ionization.

  14. Development of an integrated electrochemical system for in vitro yeast viability testing.

    PubMed

    Adami, Andrea; Ress, Cristina; Collini, Cristian; Pedrotti, Severino; Lorenzelli, Leandro

    2013-02-15

    This work describes the development and testing of a microfabricated sensor for rapid cell growth monitoring, especially focused on yeast quality assessment for wine applications. The device consists of a NMOS ISFET sensor with Si(3)N(4) gate, able to indirectly monitor extracellular metabolism through pH variation of the medium, and a solid-state reference electrode implemented with PVC membranes doped with lipophilic salts (tetrabutylammonium-tetrabutylborate (TBA-TBB) and Potassium tetrakis(4-chlorphenyl)borate (KTClpB)). The use of a solid state reference electrode enables the implementation of a large number of cell assays in parallel, without the need of external conventional reference electrodes. Microbial growth testing has been performed both in standard culture conditions and on chip at different concentrations of ethanol in order to carry out a commonly used screening of wine yeast strains. Cell growth tests can be performed in few hours, providing a fast, sensitive and low cost analysis with respect to the conventional procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  16. Fast screening of short-chain chlorinated paraffins in indoor dust samples by graphene-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Huang, Xiu; Liu, Qian; Gao, Wei; Wang, Yawei; Nie, Zhou; Yao, Shouzhuo; Jiang, Guibin

    2018-03-01

    As an important class of emerging chemical contaminants, short-chain chlorinated paraffins (SCCPs) are considered as one of the most challenging groups of compounds to analyze. In this paper, we report a new method for fast screening of SCCPs based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with graphene as a matrix and 2,5,6,9-tetrachlorodecane as an internal standard. We found that the use of graphene as MALDI matrix generated high peak intensities for SCCPs while producing few background noises. The ion fragmentation mechanisms of SCCPs in MALDI are discussed in detail. Under the optimized conditions, much lower detection limits of SCCP congeners (0.1-5ng/mL) than those reported previously were obtained. Other distinct advantages such as short analysis time and simplified sample preparation procedures are also demonstrated. The method was successfully applied in fast screening of SCCPs in indoor dust samples and monitoring of human exposure levels to SCCPs, and the results were verified by gas chromatography coupled to negative chemical ionization quadrupole time-of-flight high-resolution mass spectrometry. This work not only offers a new promising tool for SCCP studies, but also further demonstrates the promise of graphene as a new generation of MALDI matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Nondestructive Inspection System for Special Nuclear Material Using Inertial Electrostatic Confinement Fusion Neutrons and Laser Compton Scattering Gamma-Rays

    NASA Astrophysics Data System (ADS)

    Ohgaki, H.; Daito, I.; Zen, H.; Kii, T.; Masuda, K.; Misawa, T.; Hajima, R.; Hayakawa, T.; Shizuma, T.; Kando, M.; Fujimoto, S.

    2017-07-01

    A Neutron/Gamma-ray combined inspection system for hidden special nuclear materials (SNMs) in cargo containers has been developed under a program of Japan Science and Technology Agency in Japan. This inspection system consists of an active neutron-detection system for fast screening and a laser Compton backscattering gamma-ray source in coupling with nuclear resonance fluorescence (NRF) method for precise inspection. The inertial electrostatic confinement fusion device has been adopted as a neutron source and two neutron-detection methods, delayed neutron noise analysis method and high-energy neutron-detection method, have been developed to realize the fast screening system. The prototype system has been constructed and tested in the Reactor Research Institute, Kyoto University. For the generation of the laser Compton backscattering gamma-ray beam, a race track microtron accelerator has been used to reduce the size of the system. For the NRF measurement, an array of LaBr3(Ce) scintillation detectors has been adopted to realize a low-cost detection system. The prototype of the gamma-ray system has been demonstrated in the Kansai Photon Science Institute, National Institutes for Quantum and Radiological Science and Technology. By using numerical simulations based on the data taken from these prototype systems and the inspection-flow, the system designed by this program can detect 1 kg of highly enriched 235U (HEU) hidden in an empty 20-ft container within several minutes.

  18. Biophysical Properties of 9 KCNQ1 Mutations Associated with Long QT Syndrome (LQTS)

    PubMed Central

    Yang, Tao; Chung, Seo-Kyung; Zhang, Wei; Mullins, Jonathan G.L.; McCulley, Caroline H.; Crawford, Jackie; MacCormick, Judith; Eddy, Carey-Anne; Shelling, Andrew N.; French, John K.; Yang, Ping; Skinner, Jonathan R.; Roden, Dan M.; Rees, Mark I.

    2009-01-01

    Background Inherited long QT syndrome (LQTS) is characterized by prolonged QT interval on the EKG, syncope and sudden death due to ventricular arrhythmia. Causative mutations occur mostly in cardiac potassium and sodium channel subunit genes. Confidence in mutation pathogenicity is usually reached through family genotype-phenotype tracking, control population studies, molecular modelling and phylogenetic alignments, however, biophysical testing offers a higher degree of validating evidence. Methods and Results By using in-vitro electrophysiological testing of transfected mutant and wild-type LQTS constructs into Chinese Hamster Ovary cells, we investigated the biophysical properties of 9 KCNQ1 missense mutations (A46T, T265I, F269S, A302V, G316E, F339S, R360G, H455Y, and S546L) identified in a New Zealand based LQTS screening programme. We demonstrate through electrophysiology and molecular modeling that seven of the missense mutations have profound pathological dominant negative loss-of-function properties confirming their likely disease-causing nature. This supports the use of these mutations in diagnostic family screening. Two mutations (A46T, T265I) show suggestive evidence of pathogenicity within the experimental limits of biophysical testing, indicating that these variants are disease-causing via delayed or fast activation kinetics. Further investigation of the A46T family has revealed an inconsistent co-segregation of the variant with the clinical phenotype. Conclusions Electrophysiological characterisation should be used to validate LQTS pathogenicity of novel missense channelopathies. When such results are inconclusive, great care should be taken with genetic counselling and screening of such families, and alternative disease causing mechanisms should be considered. PMID:19808498

  19. Longitudinal relations of television, electronic games, and digital versatile discs with changes in diet in adolescents.

    PubMed

    Falbe, Jennifer; Willett, Walter C; Rosner, Bernard; Gortmaker, Steve L; Sonneville, Kendrin R; Field, Alison E

    2014-10-01

    Youth spend more time with screens than any activity except sleeping. Screen time is a risk factor for obesity, possibly because of the influence of food and beverage advertising on diet. We sought to assess longitudinal relations of screen time [ie, television, electronic games, digital versatile discs (DVDs)/videos, and total screen time] with the 2-y changes in consumption of foods of low nutritional quality (FLNQ) that are commonly advertised on screens [ie, sugar-sweetened beverages, fast food, sweets, salty snacks, and the sum of these foods (total FLNQ)] and fruit and vegetables. With the use of 2004, 2006, and 2008 waves of the Growing Up Today Study II, which consisted of a cohort of 6002 female and 4917 male adolescents aged 9-16 y in 2004, we assessed screen time (change and baseline) in relation to the 2-y dietary changes. Regression models included 4604 girls and 3668 boys with complete screen time and diet data on ≥2 consecutive questionnaires. Each hour-per-day increase in television, electronic games, and DVDs/videos was associated with increased intake of total FLNQ (range: 0.10-0.28 servings/d; P < 0.05). Each hour-per-day increase in total screen time predicted increased intakes of sugar-sweetened beverages, fast food, sweets, and salty snacks (range: 0.02-0.06 servings/d; P < 0.001) and decreased intakes of fruit and vegetables (range: -0.05 to -0.02 servings/d; P < 0.05). Greater screen time at baseline (except electronic games in boys) was associated with subsequent increased intake of total FLNQ, and greater screen time at baseline (except DVDs/videos) was associated with decreased intake of fruit and vegetables (P < 0.05). Across sex and food groups and in sensitivity analyses, television was most consistently associated with dietary changes. Increases in screen time were associated with increased consumption of foods and beverages of low nutritional quality and decreased consumption of fruit and vegetables. Our results caution against excessive use of screen media, especially television, in youth. © 2014 American Society for Nutrition.

  20. Study of Lamb Waves for Non-Destructive Testing Behind Screens

    NASA Astrophysics Data System (ADS)

    Kauffmann, P.; Ploix, M.-A.; Chaix, J.-F.; Gueudré, C.; Corneloup, G.; Baqué, F. AF(; )

    2018-01-01

    The inspection and control of sodium-cooled fast reactors (SFR) is a major issue for the nuclear industry. Ultrasonic solutions are under study because of the opacity of liquid sodium. In this paper, the use of leaky Lamb waves is considered for non-destructive testing (NDT) on parallel and immersed structures assimilated as plates. The first phase of our approach involved studying the propagation properties of leaky Lamb waves. Equations that model the propagation of Lamb waves in an immersed plate were solved numerically. The phase velocity can be experimentally measured using a two dimensional Fourier transform. The group velocity can be experimentally measured using a short-time Fourier transform technique. Attenuation of leaky Lamb waves is mostly due to the re-emission of energy into the surrounding fluid, and it can be measured by these two techniques.

  1. Outcomes and genotype-phenotype correlations in 52 individuals with VLCAD deficiency diagnosed by NBS and enrolled in the IBEM-IS database

    PubMed Central

    Pena, Loren D.M.; van Calcar, Sandra C.; Hansen, Joyanna; Edick, Mathew J.; Vockley, Cate Walsh; Leslie, Nancy; Cameron, Cynthia; Mohsen, Al-Walid; Berry, Susan A; Arnold, Georgianne L; Vockley, Jerry

    2016-01-01

    Very long chain acyl-CoA dehydrogenase (VLCAD) deficiency can present at various ages from the neonatal period to adulthood, and poses the greatest risk of complications during intercurrent illness or after prolonged fasting. Early diagnosis, treatment, and surveillance can reduce mortality; hence, the disorder is included in the newborn Recommended Uniform Screening Panel (RUSP) in the United States. The Inborn Errors of Metabolism Information System (IBEM-IS) was established in 2007 to collect longitudinal information on individuals with inborn errors of metabolism included in newborn screening (NBS) programs, including VLCAD deficiency. We retrospectively analyzed early outcomes for individuals who were diagnosed with VLCAD deficiency by NBS and describe initial presentations, diagnosis, clinical outcomes and treatment in a cohort of 52 individuals ages 1–18 years. Maternal prenatal symptoms were not reported, and most newborns remained asymptomatic. Cardiomyopathy was uncommon in the cohort, diagnosed in 2/52 cases. Elevations in creatine kinase were a common finding, and usually first occurred during the toddler period (1–3 years of age). Diagnostic evaluations required several testing modalities, most commonly plasma acylcarnitine profiles and molecular testing. Functional testing, including fibroblast acylcarnitine profiling and white blood cell or fibroblast enzyme assay, is a useful diagnostic adjunct if uncharacterized mutations are identified. PMID:27209629

  2. Piloting the CANRISK tool in Vancouver Coastal Health.

    PubMed

    Papineau, D; Fong, M

    2011-12-01

    Vancouver Coastal Health Authority's Healthy Living Program implemented this pilot study to test and validate the Canadian Diabetes Risk Assessment Questionnaire (CANRISK) developed by the Public Health Agency of Canada as a screening tool for undiagnosed type 2 diabetes mellitus (DM) and prediabetes. Key objectives were to test the feasibility and acceptability of screening urban ethnic groups using the CANRISK, increase awareness of risk factors for DM and preDM and develop resources for lifestyle change. The study recruited participants through community groups and churches, intraorganizational emails, primary care clinics and word of mouth. They completed the CANRISK and an oral glucose tolerance test (OGTT) either individually or as part of a group. Groups received a brief diabetes prevention information session. Documents to support lifestyle change were distributed to all participants. Participants (n = 556) were recruited among East Asian, Caucasian, South Asian and Latin American ethnic groups. Of these, 17% had OGTT results in the preDM range and 3% in the DM range. Over 90% of participants reported that the CANRISK wording was clear and that they had received useful information about lowering their diabetes risk. The benefit of using an OGTT was in identifying 11% of the sample of participants who had impaired glucose tolerance (IGT) and did not show abnormal fasting plasma glucose (FPG) results. All participants with abnormal laboratory results were provided with follow-up educational interventions in their own language.

  3. The Usefulness of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR) for Detection of Glucose Intolerance in Thai Women of Reproductive Age with Polycystic Ovary Syndrome.

    PubMed

    Wongwananuruk, Thanyarat; Rattanachaiyanont, Manee; Leerasiri, Pichai; Indhavivadhana, Suchada; Techatraisak, Kitirat; Angsuwathana, Surasak; Tanmahasamut, Prasong; Dangrat, Chongdee

    2012-01-01

    Objectives. To study the cut-off point of Homeostatic Measurement Assessment-Insulin Resistance (HOMA-IR) as a screening test for detection of glucose intolerance in Thai women with polycystic ovary syndrome (PCOS). Study Design. Cross-sectional study. Setting. Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital. Subject. Two hundred and fifty Thai PCOS women who attended the Gynecologic Endocrinology Unit, during May 2007 to January 2009. Materials and Methods. The paitents were interviewed and examined for weight, height, waist circumference, and blood pressure. Venous blood samples were drawn twice, one at 12-hour fasting and the other at 2 hours after glucose loading. Results. The prevalence of glucose intolerance in Thai PCOS women was 20.0%. The mean of HOMA-IR was 3.53  ±  7.7. Area under an ROC curve for HOMA-IR for detecting glucose intolerance was 0.82. Using the cut-off value of HOMA-IR >2.0, there was sensitivity at 84.0%, specificity at 61.0%, positive predictive value at 35.0%, negative predictive value at 93.8%, and accuracy at 65.6%. Conclusion. HOMA-IR >2.0 was used for screening test for glucose intolerance in Thai PCOS women. If the result was positive, a specific test should be done to prove the diagnosis.

  4. Secondary electrons induced by fast ions under channeling conditions. II. Screening of fast heavy ions in solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kudo, H.; Shima, K.; Seki, S.

    1991-06-01

    Ion-beam shadowing effects have been observed for secondary electrons induced by various ions in the energy range of 1.8--3.8 MeV/amu, under various channeling conditions in Si and GaAs crystals. From a comparison of the energy spectra of electrons induced by ions of equal velocity, we have found reduced shadowing effects for heavy ions (Si, S, and Cl) as compared with light (H, He, C, and O) ions. It is concluded that the reduction results from the screening of the heavy ion's nuclear charge by bound electrons. By analyzing the reduced shadowing effect, the effective nuclear charges for the heavy ionsmore » within the target crystals have been determined.« less

  5. Cardiovascular disease risk factors in persons with paraplegia: the Stockholm spinal cord injury study.

    PubMed

    Wahman, Kerstin; Nash, Mark S; Westgren, Ninni; Lewis, John E; Seiger, Ake; Levi, Richard

    2010-03-01

    To examine cardiovascular disease risk factors and risk clusters in Swedish persons with traumatic wheelchair-dependent paraplegia. Prospective examination. A total of 135 individuals aged 18-79 years with chronic (>or= 1 year) post-traumatic paraplegia. Cardiovascular disease risk factors; dyslipidemia, impaired fasting glucose, hypertension, overweight, smoking, and medication usage for dyslipidemia, hypertension, and diabetes mellitus, were analyzed according to authoritative guidelines. Stepwise regression tested the effects of age, gender, and injury characteristics on cardiovascular disease risks. High-prevalence risk factors were dyslipidemia (83.1%), hypertension (39.3%), and overweight (42.2%) with pervasive clustering of these risks. Being older was related to increased cardiovascular disease risk, except for dyslipidemia. Hypertension was more common in low-level paraplegia. Prevalence of impaired fasting glucose was lower than previously reported after paraplegia. A high percentage of persons being prescribed drug treatment for dyslipidemia and hypertension failed to reach authoritative targets for cardiovascular disease risk reduction. Swedish persons with paraplegia are at high risk for dyslipidemia, hypertension, and overweight. Impaired fasting glucose was not as common as reported in some previous studies. Pharmacotherapy for dyslipidemia and hypertension often failed to achieve recommended targets. Population-based screening and therapeutic countermeasures to these cardiovascular disease risks are indicated.

  6. Design and Solidification of Fast-Releasing Clofazimine Nanoparticles for Treatment of Cryptosporidiosis

    PubMed Central

    2017-01-01

    Clofazimine, a lipophilic (log P = 7.66) riminophenazine antibiotic approved by the US Food and Drug Administration (FDA) with a good safety record, was recently identified as a lead hit for cryptosporidiosis through a high-throughput phenotypic screen. Cryptosporidiosis requires fast-acting treatment as it leads to severe symptoms which, if untreated, result in morbidity for infants and small children. Consequently, a fast-releasing oral formulation of clofazimine in a water-dispersible form for pediatric administration is highly desirable. In this work, clofazimine nanoparticles were prepared with three surface stabilizers, hypromellose acetate succinate (HPMCAS), lecithin, and zein, using the flash nanoprecipitation (FNP) process. Drug encapsulation efficiencies of over 92% were achieved. Lyophilization and spray-drying were applied and optimized to produce redispersible nanoparticle powders. The release kinetics of these clofazimine nanoparticle powders in biorelevant media were measured and compared with those of crystalline clofazimine and the currently marketed formulation Lamprene. Remarkably improved dissolution rates and clofazimine supersaturation levels up to 90 times equilibrium solubility were observed with all clofazimine nanoparticles tested. Differential scanning calorimetry indicated a reduction of crystallinity of clofazimine in nanoparticles. These results strongly suggest that the new clofazimine nanoparticles prepared with affordable materials in this low-cost nanoparticle formulation process can be used as viable cryptosporidiosis therapeutics. PMID:28929769

  7. DG-AMMOS: a new tool to generate 3d conformation of small molecules using distance geometry and automated molecular mechanics optimization for in silico screening.

    PubMed

    Lagorce, David; Pencheva, Tania; Villoutreix, Bruno O; Miteva, Maria A

    2009-11-13

    Discovery of new bioactive molecules that could enter drug discovery programs or that could serve as chemical probes is a very complex and costly endeavor. Structure-based and ligand-based in silico screening approaches are nowadays extensively used to complement experimental screening approaches in order to increase the effectiveness of the process and facilitating the screening of thousands or millions of small molecules against a biomolecular target. Both in silico screening methods require as input a suitable chemical compound collection and most often the 3D structure of the small molecules has to be generated since compounds are usually delivered in 1D SMILES, CANSMILES or in 2D SDF formats. Here, we describe the new open source program DG-AMMOS which allows the generation of the 3D conformation of small molecules using Distance Geometry and their energy minimization via Automated Molecular Mechanics Optimization. The program is validated on the Astex dataset, the ChemBridge Diversity database and on a number of small molecules with known crystal structures extracted from the Cambridge Structural Database. A comparison with the free program Balloon and the well-known commercial program Omega generating the 3D of small molecules is carried out. The results show that the new free program DG-AMMOS is a very efficient 3D structure generator engine. DG-AMMOS provides fast, automated and reliable access to the generation of 3D conformation of small molecules and facilitates the preparation of a compound collection prior to high-throughput virtual screening computations. The validation of DG-AMMOS on several different datasets proves that generated structures are generally of equal quality or sometimes better than structures obtained by other tested methods.

  8. Preparticipation Screening of Athletic Officials: SEC Football Referees at Risk.

    PubMed

    Turner, John L; Walters, Rod; Leski, Mark J; Saywell, Robert M; Wooldridge, J Scott

    2003-03-01

    Although preparticipation screening for athletes is commonplace, few studies have addressed the issue for those officiating at games. To review current data on physiologic stress on sports officials, to obtain prevalence data on health parameters for football officials, and to determine the outcomes when screening criteria are applied in preseason exams. A protocol was established using health history questionnaires and physical exams with laboratory screening to assess the health of all football officials working in the Southeastern Conference (SEC) from 1997 to 2000. The main outcome measure was the prevalence of cardiac risk factors as determined by American College of Sports Medicine guidelines. Initial screening of 102 football officials revealed that 10.1% of SEC referees had elevated systolic blood pressure, 13.9% had elevated diastolic blood pressure, and 3.8% had resting tachycardia. Average body mass index (BMI) was 28.6 kg/m2, with 87.3% having a BMI that exceeded 25 (overweight). About one-third (31.6%) had a BMI greater than 30 (obese). Total fasting cholesterol exceeded 200 mg/dL in 44.2%, HDL levels were below 35 mg/dL in 34.3%, and LDL levels were above 120 mg/dL in 62.3%. Compared with age-adjusted national data, there were more overweight and more obese officials, but they had lower systolic and diastolic blood pressures and lower mean total cholesterol levels. Using the Framingham Study prediction model to estimate coronary heart disease (CHD) risk, analysis revealed that referees had a lower risk than the national 10-year CHD risk but a higher risk compared with that of the low-risk population. These data reveal a greater need for graded exercise testing. The higher rates of obesity among officials will promote further screening for CHD risk factors.

  9. Screening for type 2 diabetes: a short report for the National Screening Committee.

    PubMed

    Waugh, N R; Shyangdan, D; Taylor-Phillips, S; Suri, G; Hall, B

    2013-08-01

    The prevalence of type 2 diabetes mellitus (T2DM) has been increasing, owing to increases in overweight and obesity, decreasing physical activity and the changing demographic structure of the population. People can develop T2DM without symptoms and up to 20% may be undiagnosed. They may have diabetic complications, such as retinopathy, by the time they are diagnosed, or may suffer a heart attack, without warning. Undiagnosed diabetes can be detected by raised blood glucose levels. The aim of this review was to provide an update for the UK National Screening Committee (NSC) on screening for T2DM. As this review was undertaken to update a previous Health Technology Assessment review published in 2007, and a more recent Scottish Public Health Network review, searches for evidence were restricted from 2009 to end of January 2012, with selected later studies added. The databases searched were MEDLINE, EMBASE, MEDLINE-in-Process & Other Non-Indexed Citations, Science Citation Index and Conference Proceedings Citation Index. The case for screening was considered against the criteria used by the NSC to assess proposed population screening programmes. Population screening for T2DM does not meet all of the NSC criteria. Criterion 12, on optimisation of existing management, has not been met. A report by the National Audit Office (NAO) gives details of shortcomings. Criterion 13 requires evidence from high-quality randomised controlled trials that screening is beneficial. This has not been met. The Ely trial of screening showed no benefit. The ADDITION trial was not a trial of screening, but showed no benefit in cardiovascular outcomes from intensive management in people with screen-detected T2DM. Criterion 18 on staffing and facilities does not appear to have been met, according to the NAO report. Criterion 19 requires that all other options, including prevention, should have been considered. A large proportion of cases of T2DM could be prevented if people avoided becoming overweight or obese. The first stage of selection would use risk factors, using data held on general practitioner computer systems, using the QDiabetes Risk Score, or by sending out questionnaires, using the Finnish Diabetes Risk Score (FINDRISC). Those at high risk would have a measure of blood glucose. There is no perfect screening test. Glycated haemoglobin (HbA1c) testing has advantages in not requiring a fasting sample, and because it is a predictor of vascular disease across a wider range than just the diabetic one. However, it lacks sensitivity and would miss some people with diabetes. Absolute values of HbA1c may be more useful as part of overall risk assessment than a dichotomous 'diabetes or not diabetes' diagnosis. The oral glucose tolerance test is more sensitive, but inconvenient, more costly, has imperfect reproducibility and is less popular, meaning that uptake would be lower. When considered against the NSC criteria, the case for screening is less strong than it was in the 2007 review. The main reason is the absence of cardiovascular benefit in the two trials published since the previous review. There is a case for selective screening as part of overall vascular risk assessment. Population screening for T2DM does not meet all of the NSC criteria. The National Institute for Health Research Health Technology Assessment programme.

  10. Pilot study to investigate the feasibility of the Home Falls and Accidents Screening Tool (HOME FAST) to identify older Malaysian people at risk of falls

    PubMed Central

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin

    2016-01-01

    Objective The relationship between home hazards and falls in older Malaysian people is not yet fully understood. No tools to evaluate the Malaysian home environment currently exist. Therefore, this study aimed to pilot the Home Falls and Accidents Screening Tool (HOME FAST) to identify hazards in Malaysian homes, to evaluate the feasibility of using the HOME FAST in the Malaysian Elders Longitudinal Research (MELoR) study and to gather preliminary data about the experience of falls among a small sample of Malaysian older people. Design A cross-sectional pilot study was conducted. Setting An urban setting in Kuala Lumpur. Participants 26 older people aged 60 and over were recruited from the control group of a related research project in Malaysia, in addition to older people known to the researchers. Primary outcome measure The HOME FAST was applied with the baseline survey for the MELoR study via a face-to-face interview and observation of the home by research staff. Results The majority of the participants were female, of Malay or Chinese ethnicity and living with others in a double-storeyed house. Falls were reported in the previous year by 19% and 80% of falls occurred at home. Gender and fear of falling had the strongest associations with home hazards. Most hazards were detected in the bathroom area. A small number of errors were detected in the HOME FAST ratings by researchers. Conclusions The HOME FAST is feasible as a research and clinical tool for the Malaysian context and is appropriate for use in the MELoR study. Home hazards were prevalent in the homes of older people and further research with the larger MELoR sample is needed to confirm the validity of using the HOME FAST in Malaysia. Training in the use of the HOME FAST is needed to ensure accurate use by researchers. PMID:27531736

  11. The McPygmalion Effect.

    ERIC Educational Resources Information Center

    Shimko, Barbara Whitaker

    1990-01-01

    Project Transition screens, trains, and places welfare recipients in fast food restaurant jobs. Training focuses on employee responsibility for managers' expectations and on behavior that will raise those expectations of new employees. (SK)

  12. Evaluation and recommendation of sensitivity analysis methods for application to Stochastic Human Exposure and Dose Simulation models.

    PubMed

    Mokhtari, Amirhossein; Christopher Frey, H; Zheng, Junyu

    2006-11-01

    Sensitivity analyses of exposure or risk models can help identify the most significant factors to aid in risk management or to prioritize additional research to reduce uncertainty in the estimates. However, sensitivity analysis is challenged by non-linearity, interactions between inputs, and multiple days or time scales. Selected sensitivity analysis methods are evaluated with respect to their applicability to human exposure models with such features using a testbed. The testbed is a simplified version of a US Environmental Protection Agency's Stochastic Human Exposure and Dose Simulation (SHEDS) model. The methods evaluated include the Pearson and Spearman correlation, sample and rank regression, analysis of variance, Fourier amplitude sensitivity test (FAST), and Sobol's method. The first five methods are known as "sampling-based" techniques, wheras the latter two methods are known as "variance-based" techniques. The main objective of the test cases was to identify the main and total contributions of individual inputs to the output variance. Sobol's method and FAST directly quantified these measures of sensitivity. Results show that sensitivity of an input typically changed when evaluated under different time scales (e.g., daily versus monthly). All methods provided similar insights regarding less important inputs; however, Sobol's method and FAST provided more robust insights with respect to sensitivity of important inputs compared to the sampling-based techniques. Thus, the sampling-based methods can be used in a screening step to identify unimportant inputs, followed by application of more computationally intensive refined methods to a smaller set of inputs. The implications of time variation in sensitivity results for risk management are briefly discussed.

  13. Automated recycling of chemistry for virtual screening and library design.

    PubMed

    Vainio, Mikko J; Kogej, Thierry; Raubacher, Florian

    2012-07-23

    An early stage drug discovery project needs to identify a number of chemically diverse and attractive compounds. These hit compounds are typically found through high-throughput screening campaigns. The diversity of the chemical libraries used in screening is therefore important. In this study, we describe a virtual high-throughput screening system called Virtual Library. The system automatically "recycles" validated synthetic protocols and available starting materials to generate a large number of virtual compound libraries, and allows for fast searches in the generated libraries using a 2D fingerprint based screening method. Virtual Library links the returned virtual hit compounds back to experimental protocols to quickly assess the synthetic accessibility of the hits. The system can be used as an idea generator for library design to enrich the screening collection and to explore the structure-activity landscape around a specific active compound.

  14. Artificial intelligence for breast cancer screening: Opportunity or hype?

    PubMed

    Houssami, Nehmat; Lee, Christoph I; Buist, Diana S M; Tao, Dacheng

    2017-12-01

    Interpretation of mammography for breast cancer (BC) screening can confer a mortality benefit through early BC detection, can miss a cancer that is present or fast growing, or can result in false-positives. Efforts to improve screening outcomes have mostly focused on intensifying imaging practices (double instead of single-reading, more frequent screens, or supplemental imaging) that may add substantial resource expenditures and harms associated with population screening. Less attention has been given to making mammography screening practice 'smarter' or more efficient. Artificial intelligence (AI) is capable of advanced learning using large complex datasets and has the potential to perform tasks such as image interpretation. With both highly-specific capabilities, and also possible un-intended (and poorly understood) consequences, this viewpoint considers the promise and current reality of AI in BC detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Monitoring food pathogens: Novel instrumentation for cassette PCR testing

    PubMed Central

    Hunt, Darin; Figley, Curtis; Lauzon, Jana; Figley, Rachel; Pilarski, Linda M.; McMullen, Lynn M.; Pilarski, Patrick M.

    2018-01-01

    In this manuscript, we report the design and development of a fast, reliable instrument to run gel-based cassette polymerase chain reactions (PCR). Here termed the GelCycler Mark II, our instrument is a miniaturized molecular testing system that is fast, low cost and sensitive. Cassette PCR utilizes capillary reaction units that carry all reagents needed for PCR, including primers and Taq polymerase, except the sample, which is loaded at the time of testing. Cassette PCR carries out real time quantitative PCR followed by melt curve analysis (MCA) to verify amplicon identity at the expected melt temperature (Tm). The cassette PCR technology is well developed, particularly for detecting pathogens, and has been rigorously validated for detecting pathogenic Escherichia coli in meat samples. However, the work has been hindered by the lack of a robust and stable instrument to carry out the PCR, which requires fast and accurate temperature regulation, improved light delivery and fluorescent recording, and faster PCR reactions that maintain a high sensitivity of detection. Here, we report design and testing of a new instrument to address these shortcomings and to enable standardized testing by cassette PCR and commercial manufacture of a robust and accurate instrument that can be mass produced to deliver consistent performance. As a corollary to our new instrument development, we also report the use of an improved design approach using a machined aluminum cassette to meet the new instrument standards, prevent any light bleed across different trenches in each cassette, and allow testing of a larger number of samples for more targets in a single run. The GelCycler Mark II can detect and report E. coli contamination in 41 minutes. Sample positives are defined in as having a melt curve comparable to the internal positive control, with peak height exceeding that of the internal negative control. In a fractional analysis, as little as 1 bacterium per capillary reaction unit is directly detectable, with no enrichment step, in 35 cycles of PCR/MCA, in a total time of 53 minutes, making this instrument and technology among the very best for speed and sensitivity in screening food for pathogenic contamination. PMID:29746561

  16. The "metabolic syndrome" is less useful than random plasma glucose to screen for glucose intolerance.

    PubMed

    El Bassuoni, Eman A; Ziemer, David C; Kolm, Paul; Rhee, Mary K; Vaccarino, Viola; Tsui, Circe W; Kaufman, Jack M; Osinski, G Eileen; Koch, David D; Narayan, K M Venkat; Weintraub, William S; Phillips, Lawrence S

    2008-09-01

    To compare the utility of metabolic syndrome (MetS) to random plasma glucose (RPG) in identifying people with diabetes or prediabetes. RPG was measured and an OGTT was performed in 1155 adults. Test performance was measured by area under the receiver-operating-characteristic curve (AROC). Diabetes was found in 5.1% and prediabetes in 20.0%. AROC for MetS with fasting plasma glucose (FPG) was 0.80 to detect diabetes, and 0.76 for diabetes or prediabetes--similar to RPG alone (0.82 and 0.72). However, the AROC for MetS excluding fasting plasma glucose was lower: 0.69 for diabetes (p<0.01 vs. both RPG and MetS with FPG), and 0.69 for diabetes or prediabetes. AROCs for MetS with FPG and RPG were comparable and higher for recognizing diabetes in blacks vs. whites, and females vs. males. MetS with FPG was superior to RPG for identifying diabetes only in subjects with age <40 or BMI <25. MetS features can be used to identify risk of diabetes, but predictive usefulness is driven largely by FPG. Overall, to identify diabetes or prediabetes in blacks and whites with varying age and BMI, MetS is no better than RPG--a more convenient and less expensive test.

  17. Delirium, Frailty, and Fast-Track Surgery in Oncogeriatrics: Is There a Link?

    PubMed Central

    Monacelli, Fiammetta; Signori, Alessio; Prefumo, Matteo; Giannotti, Chiara; Nencioni, Alessio; Romairone, Emanuele; Scabini, Stefano; Odetti, Patrizio

    2018-01-01

    Background/Aims Postoperative delirium (POD) is more frequent in elderly patients undergoing major cancer surgery. The interplay between individual clinical vulnerability and a series of perioperative factors seems to play a relevant role. Surgery is the first-line treatment option for cancer, and fast-track surgery (FTS) has been documented to decrease postoperative complications. The study sought to assess, after comprehensive geriatric assessment (CGA) and frailty stratification (Rockwood 40 items index), which perioperative parameters were predictive of POD development in elderly patients undergoing FTS for colorectal cancer. Methods A total of 107 consecutive subjects admitted for elective colorectal FTS were enrolled. All patients underwent CGA, frailly stratification, Timed up & go (TUG) test, 4AT test for delirium screening, anesthesiologists physical status classification, and Dindo-Clavien classification. Results The incidence of POD was 12.3%. Patients’ prevalent clinical phenotype was pre-frail. The multivariate analysis indicated physical performance (TUG in seconds) as the most significant predictor of POD for each second of increase. Conclusions Only few procedure-specific studies have examined the impact of FTS for colorectal cancer on POD. This is the first study to investigate the risk factors for POD, in a vulnerable octogenarian oncogeriatric population submitted to FTS surgery and frailty stratification. PMID:29515621

  18. Inexpensive and fast pathogenic bacteria screening using field-effect transistors.

    PubMed

    Formisano, Nello; Bhalla, Nikhil; Heeran, Mel; Reyes Martinez, Juana; Sarkar, Amrita; Laabei, Maisem; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Flitsch, Sabine; Estrela, Pedro

    2016-11-15

    While pathogenic bacteria contribute to a large number of globally important diseases and infections, current clinical diagnosis is based on processes that often involve culturing which can be time-consuming. Therefore, innovative, simple, rapid and low-cost solutions to effectively reduce the burden of bacterial infections are urgently needed. Here we demonstrate a label-free sensor for fast bacterial detection based on metal-oxide-semiconductor field-effect transistors (MOSFETs). The electric charge of bacteria binding to the glycosylated gates of a MOSFET enables quantification in a straightforward manner. We show that the limit of quantitation is 1.9×10(5) CFU/mL with this simple device, which is more than 10,000-times lower than is achieved with electrochemical impedance spectroscopy (EIS) and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-ToF) on the same modified surfaces. Moreover, the measurements are extremely fast and the sensor can be mass produced at trivial cost as a tool for initial screening of pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Hydrophobic polymers for orodispersible films: a quality by design approach.

    PubMed

    Borges, Ana Filipa; Silva, Branca M A; Silva, Cláudia; Coelho, Jorge F J; Simões, Sérgio

    2016-10-01

    To develop orodispersible films (ODF) based on hydrophobic polymers with higher stability to ordinary environmental humidity conditions without compromising their fast disintegration time. A quality by design approach was applied to screen three different formulations each one based on a different hydrophobic polymer: polyvinyl acetate, methacrylate-based copolymer and shellac. The screening formulations were characterized regarding their mechanical properties, residual water content, disintegration time and appearance, in order to find a suitable ODF formulation according to established critical quality attributes. The selected critical process parameters for the selection of appropriate ODF formulations were the percentage of the different excipients and the plasticizer type. Three hydrophobic-based matrices with fast disintegration were developed. These were generically composed by a hydrophobic polymer, a stabilizer, a disintegrant and a plasticizer. It verified that the common components within the three different formulations behave differently depending on the system/chemical environment that they were included. It was shown that it is possible to develop oral films based on hydrophobic polymers with fast disintegration time, good texture and appearance, breaking a paradigm of the ODF research field.

  20. Fast screening of analytes for chemical reactions by reactive low-temperature plasma ionization mass spectrometry.

    PubMed

    Zhang, Wei; Huang, Guangming

    2015-11-15

    Approaches for analyte screening have been used to aid in the fine-tuning of chemical reactions. Herein, we present a simple and straightforward analyte screening method for chemical reactions via reactive low-temperature plasma ionization mass spectrometry (reactive LTP-MS). Solution-phase reagents deposited on sample substrates were desorbed into the vapor phase by action of the LTP and by thermal desorption. Treated with LTP, both reagents reacted through a vapor phase ion/molecule reaction to generate the product. Finally, protonated reagents and products were identified by LTP-MS. Reaction products from imine formation reaction, Eschweiler-Clarke methylation and the Eberlin reaction were detected via reactive LTP-MS. Products from the imine formation reaction with reagents substituted with different functional groups (26 out of 28 trials) were successfully screened in a time of 30 s each. Besides, two short-lived reactive intermediates of Eschweiler-Clarke methylation were also detected. LTP in this study serves both as an ambient ionization source for analyte identification (including reagents, intermediates and products) and as a means to produce reagent ions to assist gas-phase ion/molecule reactions. The present reactive LTP-MS method enables fast screening for several analytes from several chemical reactions, which possesses good reagent compatibility and the potential to perform high-throughput analyte screening. In addition, with the detection of various reactive intermediates (intermediates I and II of Eschweiler-Clarke methylation), the present method would also contribute to revealing and elucidating reaction mechanisms. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Using the Bergman-Paris Question to screen seniors in the emergency department.

    PubMed

    Lague, Antoine; Voyer, Philippe; Ouellet, Marie-Christine; Boucher, Vale Rie; Giroux, Marianne; Pelletier, Mathieu; Gouin, E Milie; Daoust, Raoul; Berthelot, Simon; Morin, Miche le; Minh Vu, Thien Tuong; Lee, Jacques; Brousseau, Audrey-Anne; Sirois, Marie-Jose E; E Mond, Marcel

    2017-10-16

    In the fast pace of the Emergency Department (ED), clinicians are in need of tailored screening tools to detect seniors who are at risk of adverse outcomes. We aimed to explore the usefulness of the Bergman-Paris Question (BPQ) to expose potential undetected geriatric syndromes in community-living seniors presenting to the ED. This is a planned sub-study of the INDEED multicentre prospective cohort study, including independent or semi-independent seniors (≥65 years old) admitted to hospital after an ED stay ≥8 hours and who were not delirious. Patients were assessed using validated screening tests for 3 geriatric syndromes: cognitive and functional impairment, and frailty. The BPQ was asked upon availability of a relative at enrolment. BPQ's sensitivity and specificity analyses were used to ascertain outcomes. A response to the BPQ was available for 171 patients (47% of the main study's cohort). Of this number, 75.4% were positive (suggesting impairment), and 24.6% were negative. To detect one of the three geriatric syndromes, the BPQ had a sensitivity of 85.4% (95% CI [76.3, 92.0]) and a specificity of 35.4% (95% CI [25.1, 46.7]). Similar results were obtained for each separate outcome. Odds ratio demonstrated a higher risk of presence of geriatric syndromes. The Bergman-Paris Question could be an ED screening tool for possible geriatric syndrome. A positive BPQ should prompt the need of further investigations and a negative BPQ possibly warrants no further action. More research is needed to validate the usefulness of the BPQ for day-to-day geriatric screening by ED professionals or geriatricians.

  2. Nanostructured materials detect epidermal growth factor receptor, neuron specific enolase and carcinoembryonic antigen

    NASA Astrophysics Data System (ADS)

    Stefan-van Staden, Raluca-Ioana; Comnea-Stancu, Ionela Raluca; Surdu-Bob, Carmen Cristina; Badulescu, Marius

    2015-09-01

    New nanostructured materials based on thin films of Cu and Ni deposited on textile material (veil), as well as gold nanostructured microspheres were used for the design of new stochastic sensors. The stochastic sensors were able to detect simultaneously a panel of biomarkers comprising epidermal growth factor receptor, neuron specific enolase, and carcinoembryonic antigen from whole blood samples with high reliabilities - recovery tests higher than 97.00%, with a RSD (%) lower than 0.1%. The stochastic sensors had shown high sensitivities and low determination levels for the detection of the proposed panel of biomarkers making early detection of lung cancer possible by fast screening of whole blood.

  3. Characterization of anti-theft devices directly from the surface of banknotes via easy ambient sonic spray ionization mass spectrometry.

    PubMed

    Schmidt, Eduardo Morgado; Franco, Marcos Fernando; Cuelbas, Claudio José; Zacca, Jorge Jardim; de Carvalho Rocha, Werickson Fortunato; Borges, Rodrigo; de Souza, Wanderley; Sawaya, Alexandra Christine Helena Frankland; Eberlin, Marcos Nogueira; Correa, Deleon Nascimento

    2015-09-01

    Using Brazilian banknotes as a test case, forensic examination and identification of Rhodamine B dye anti-theft device (ATD) staining on banknotes were performed. Easy ambient sonic spray ionization mass spectrometry (EASI-MS) was used since it allows fast and simple analysis with no sample preparation providing molecular screening of the surface with direct desorption and ionization of the security dye. For a more accurate molecular characterization of the ATD dye, Q Exactive Orbitrap™ Fourier transform (tandem) mass spectrometry using eletrospray ionization (ESI-HRMS/MS) was also applied. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Furosemide/Fludrocortisone Test and Clinical Parameters to Diagnose Incomplete Distal Renal Tubular Acidosis in Kidney Stone Formers.

    PubMed

    Dhayat, Nasser A; Gradwell, Michael W; Pathare, Ganesh; Anderegg, Manuel; Schneider, Lisa; Luethi, David; Mattmann, Cedric; Moe, Orson W; Vogt, Bruno; Fuster, Daniel G

    2017-09-07

    Incomplete distal renal tubular acidosis is a well known cause of calcareous nephrolithiasis but the prevalence is unknown, mostly due to lack of accepted diagnostic tests and criteria. The ammonium chloride test is considered as gold standard for the diagnosis of incomplete distal renal tubular acidosis, but the furosemide/fludrocortisone test was recently proposed as an alternative. Because of the lack of rigorous comparative studies, the validity of the furosemide/fludrocortisone test in stone formers remains unknown. In addition, the performance of conventional, nonprovocative parameters in predicting incomplete distal renal tubular acidosis has not been studied. We conducted a prospective study in an unselected cohort of 170 stone formers that underwent sequential ammonium chloride and furosemide/fludrocortisone testing. Using the ammonium chloride test as gold standard, the prevalence of incomplete distal renal tubular acidosis was 8%. Sensitivity and specificity of the furosemide/fludrocortisone test were 77% and 85%, respectively, yielding a positive predictive value of 30% and a negative predictive value of 98%. Testing of several nonprovocative clinical parameters in the prediction of incomplete distal renal tubular acidosis revealed fasting morning urinary pH and plasma potassium as the most discriminative parameters. The combination of a fasting morning urinary threshold pH <5.3 with a plasma potassium threshold >3.8 mEq/L yielded a negative predictive value of 98% with a sensitivity of 85% and a specificity of 77% for the diagnosis of incomplete distal renal tubular acidosis. The furosemide/fludrocortisone test can be used for incomplete distal renal tubular acidosis screening in stone formers, but an abnormal furosemide/fludrocortisone test result needs confirmation by ammonium chloride testing. Our data furthermore indicate that incomplete distal renal tubular acidosis can reliably be excluded in stone formers by use of nonprovocative clinical parameters. Copyright © 2017 by the American Society of Nephrology.

  5. Evaluation of a multiplex real-time PCR assay for detecting pathogens in cardiac valve tissue in patients with endocarditis.

    PubMed

    Fernández, Angel L; Varela, Eduardo; Martínez, Lucía; Martínez, Amparo; Sierra, Juan; González-Juanatey, José R; Regueiro, Benito

    2010-10-01

    With a novel real-time multiplex polymerase chain reaction test, the LightCycler SeptiFast® test, 25 bacterial and fungal species can be identified directly in blood. The SeptiFast® test has been used for rapid etiologic diagnosis in infectious endocarditis using blood samples but has not been evaluated directly on cardiac vegetations in patients being treated for infectious endocarditis. We prospectively analyzed 15 samples of heart valve tissue with active infectious endocarditis using the SeptiFast® test and compared the test's sensitivity with that of blood culture, valve tissue culture, and the SeptiFast® test in blood. The sensitivity of the SeptiFast test in heart valve tissue was 100%. The test results confirmed the diagnosis obtained using blood culture in 13 cases and identified the pathogen in 2 cases where blood culture tested negative. The sensitivity of the SeptiFast® test in heart valve tissue was greater than that obtained with conventional culture of vegetations or with the SeptiFast test in blood.

  6. An Efficient New Device to Release Eggs From Heterodera glycines

    PubMed Central

    Faghihi, J.; Ferris, J. M.

    2000-01-01

    A new apparatus to release eggs from cysts of soybean cyst nematode (Heterodera glycines) is described and its efficiency evaluated. A rubber stopper was mounted on a bolt, and cysts were ground against a 60-mesh screen. Eggs and second-stage juveniles were washed into a series of screens nested underneath the apparatus. This method was fast and efficient, and had no ill effect on prepared inoculum. PMID:19270996

  7. An Efficient New Device to Release Eggs From Heterodera glycines.

    PubMed

    Faghihi, J; Ferris, J M

    2000-12-01

    A new apparatus to release eggs from cysts of soybean cyst nematode (Heterodera glycines) is described and its efficiency evaluated. A rubber stopper was mounted on a bolt, and cysts were ground against a 60-mesh screen. Eggs and second-stage juveniles were washed into a series of screens nested underneath the apparatus. This method was fast and efficient, and had no ill effect on prepared inoculum.

  8. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter W. Carr; K.M. Fuller; D.R. Stoll

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for eachmore » analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.« less

  9. Smart Plasmonic Glucose Nanosensors as Generic Theranostic Agents for Targeting-Free Cancer Cell Screening and Killing.

    PubMed

    Chen, Limei; Li, Haijuan; He, Haili; Wu, Haoxi; Jin, Yongdong

    2015-07-07

    Fast and accurate identification of cancer cells from healthy normal cells in a simple, generic way is very crucial for early cancer detection and treatment. Although functional nanoparticles, like fluorescent quantum dots and plasmonic Au nanoparticles (NPs), have been successfully applied for cancer cell imaging and photothermal therapy, they suffer from the main drawback of needing time-consuming targeting preparation for specific cancer cell detection and selective ablation. The lack of a generic and effective method therefore limits their potential high-throughput cancer cell preliminary screening and theranostic applications. We report herein a generic in vitro method for fast, targeting-free (avoiding time-consuming preparations of targeting moiety for specific cancer cells) visual screening and selective killing of cancer cells from normal cells, by using glucose-responsive/-sensitive glucose oxidase-modified Ag/Au nanoshells (Ag/Au-GOx NSs) as a smart plasmonic theranostic agent. The method is generic to some extent since it is based on the distinct localized surface plasmon resonance (LSPR) responses (and colors) of the smart nanoprobe with cancer cells (typically have a higher glucose uptake level) and normal cells.

  10. Cancer Screening Test Use - United States, 2015.

    PubMed

    White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C

    2017-03-03

    Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.

  11. Evaluation of 9 rapid diagnostic tests for screening HIV infection, in Lomé, Togo.

    PubMed

    Dagnra, A Y; Dossim, S; Salou, M; Nyasenu, T; Ali-Edje, K; Ouro-Médeli, A; Doufan, M; Ehlan, A; Prince-David, M

    2014-12-01

    HIV rapid diagnostic tests (RDT) could be greatly contributive for a universal access to HIV diagnosis. However, according to the WHO, these tests need to be assessed before they can be used in routine. We assessed 9 RDT in routine clinical use between 2009 and 2013. The sensitivity and specificity observed for 7 tests were≥99% and≥98%, respectively: FIRST RESPONSE HIV1-2-O PMC Medical, India, GENIE Fast HIV 1-2 and GENIE™ III HIV(1/2) Bio-Rad, France, HIV TRI-DOT+Ag;J. Mitra, INDIA; SD BIOLINE HIV(1/2) 3.0 and SD BIOLINE HIV/SYPHILIS DUO Standard Diagnostic, Korea; and VIKIA HIV(1/2); BioMérieux, France. Two tests had performances inferior to WHO recommendations: INSTI HIV1/2 Biolytical Canada; sensitivity=97.8% and HEXAGON HIV HUMAN GmbH Germany; specificity=94.8%. Seven of 9 RDT had excellent performances. Nevertheless, they can be used only after training staff, and taking into account national algorithm for their safe use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. [Test evaluation and strategy proposal to detect and to characterize carbapenemase-producing gram negative bacilli].

    PubMed

    Muñoz, Constanza; Zumarán, Cecilia; González, Tamara; Wozniak, Aniela; Castillo, Claudia; García, Patricia

    2017-08-01

    The detection of carbapenemase-producing gram negative bacilli is complicated, because there are available multiple options of test. The confirmation of the enzyme by molecular characterization is not available in all laboratories in our country. To propose a fast, efficient and simple strategy to detect and confirm CPB. 39 CPB isolates and 8 non-producing were used to evaluate the phenotypic test Carba NP, CarbAcineto NP and Blue-Carba, validating the test Xpert® Carba-R, to be used directly with bacterial colonies with conventional PCR. The sensitivity of Carba NP, CarbAcineto NP and Blue-Carba was 79,5; 87,2 y 84,6%, respectively; and specificity was 79.5; 87.2 and 84.6%, respectively. The limit of detection of Xpert® Carba-R was different for each carbapenemasa: 40.8 ufc/reaction to KPC and NDM and 30.6 ufc/reaction to VIM. On isolates with decreased susceptibility to carbapenems we propose to use as screening the test CarbAcineto NP, follow by Xpert®Carba-R to characterize the carbapenemase and adopt specific infection control measures.

  13. Transfer Behavior of the Weakly Acidic BCS Class II Drug Valsartan from the Stomach to the Small Intestine During Fasted and Fed States.

    PubMed

    Hamed, Rania; Alnadi, Sabreen Hasan

    2018-05-07

    The objective of this study was to investigate the transfer behavior of the weakly acidic BCS class II drug valsartan from the stomach to the small intestine during fasted and fed states. An in vitro transfer model previously introduced by Kostewicz et al. (J Pharm Pharmacol 56(1):43-51, 2004) based on a syringe pump and a USP paddle apparatus was used to determine the concentration profiles of valsartan in the small intestine. Donor phases of simulated gastric fluid during fasted (FaSSGF) and fed (FeSSGF) states were used to predisperse Diovan® tablets (160 mg valsartan). The initial concentrations of valsartan in FaSSGF and FeSSGF were 6.2 and 91.8%, respectively. Valsartan dispersions were then transferred to acceptor phases that simulate intestinal fluid and cover the physiological properties (pH, buffer capacity, and ionic strength) of the gastrointestinal fluid at a flow rate of 2 mL/min. The pH measurements were reported at time intervals corresponded to those of the transfer experiments to investigate the effect of percent dissolved of valsartan in the donor phase on lowering the pH of the acceptor phases. The f2 similarity test was used to compare the concentration profiles in the acceptor phases. In fasted state, the concentration of valsartan in the acceptor phases ranged between 33.1 and 89.4% after 240 min. Whereas in fed state, valsartan was fully dissolved in all acceptor phases within a range of 94.5-104.9% after 240 min. Therefore, the transfer model provides a useful screen for the concentrations of valsartan in the small intestine during fasted and fed states.

  14. Telemedicine support shortens length of stay after fast-track hip replacement.

    PubMed

    Vesterby, Martin Svoldgaard; Pedersen, Preben Ulrich; Laursen, Malene; Mikkelsen, Søren; Larsen, Jens; Søballe, Kjeld; Jørgensen, Lene Bastrup

    2017-02-01

    Background and purpose - Telemedicine could allow patients to be discharged more quickly after surgery and contribute to improve fast-track procedures without compromising quality, patient safety, functionality, anxiety, or other patient-perceived parameters. We investigated whether using telemedicine support (TMS) would permit hospital discharge after 1 day without loss of self-assessed quality of life, loss of functionality, increased anxiety, increased rates of re-admission, or increased rates of complications after hip replacement. Patients and methods - We performed a randomized controlled trial involving 72 Danish patients in 1 region who were referred for elective fast-track total hip replacement between August 2009 and March 2011 (654 were screened for eligibility). Half of the patients received a telemedicine solution connected to their TV. The patients were followed until 1 year after surgery. Results - Length of stay was reduced from 2.1 days (95% CI: 2.0-2.3) to 1.1 day (CI: 0.9-1.4; p < 0.001) with the TMS intervention. Health-related quality of life increased in both groups, but there were no statistically significant differences between groups. There were also no statistically significant differences between groups regarding timed up-and-go test and Oxford hip score at 3-month follow-up. At 12-month follow-up, the rates of complications and re-admissions were similar between the groups, but the number of postoperative hospital contacts was lower in the TMS group. Interpretation - Length of postoperative stay was shortened in patients with the TMS solution, without compromising patient-perceived or clinical parameters in patients undergoing elective fast-track surgery. These results indicate that telemedicine can be of value in fast-track treatment of patients undergoing total hip replacement.

  15. Large-Scale Off-Target Identification Using Fast and Accurate Dual Regularized One-Class Collaborative Filtering and Its Application to Drug Repurposing.

    PubMed

    Lim, Hansaim; Poleksic, Aleksandar; Yao, Yuan; Tong, Hanghang; He, Di; Zhuang, Luke; Meng, Patrick; Xie, Lei

    2016-10-01

    Target-based screening is one of the major approaches in drug discovery. Besides the intended target, unexpected drug off-target interactions often occur, and many of them have not been recognized and characterized. The off-target interactions can be responsible for either therapeutic or side effects. Thus, identifying the genome-wide off-targets of lead compounds or existing drugs will be critical for designing effective and safe drugs, and providing new opportunities for drug repurposing. Although many computational methods have been developed to predict drug-target interactions, they are either less accurate than the one that we are proposing here or computationally too intensive, thereby limiting their capability for large-scale off-target identification. In addition, the performances of most machine learning based algorithms have been mainly evaluated to predict off-target interactions in the same gene family for hundreds of chemicals. It is not clear how these algorithms perform in terms of detecting off-targets across gene families on a proteome scale. Here, we are presenting a fast and accurate off-target prediction method, REMAP, which is based on a dual regularized one-class collaborative filtering algorithm, to explore continuous chemical space, protein space, and their interactome on a large scale. When tested in a reliable, extensive, and cross-gene family benchmark, REMAP outperforms the state-of-the-art methods. Furthermore, REMAP is highly scalable. It can screen a dataset of 200 thousands chemicals against 20 thousands proteins within 2 hours. Using the reconstructed genome-wide target profile as the fingerprint of a chemical compound, we predicted that seven FDA-approved drugs can be repurposed as novel anti-cancer therapies. The anti-cancer activity of six of them is supported by experimental evidences. Thus, REMAP is a valuable addition to the existing in silico toolbox for drug target identification, drug repurposing, phenotypic screening, and side effect prediction. The software and benchmark are available at https://github.com/hansaimlim/REMAP.

  16. Large-Scale Off-Target Identification Using Fast and Accurate Dual Regularized One-Class Collaborative Filtering and Its Application to Drug Repurposing

    PubMed Central

    Poleksic, Aleksandar; Yao, Yuan; Tong, Hanghang; Meng, Patrick; Xie, Lei

    2016-01-01

    Target-based screening is one of the major approaches in drug discovery. Besides the intended target, unexpected drug off-target interactions often occur, and many of them have not been recognized and characterized. The off-target interactions can be responsible for either therapeutic or side effects. Thus, identifying the genome-wide off-targets of lead compounds or existing drugs will be critical for designing effective and safe drugs, and providing new opportunities for drug repurposing. Although many computational methods have been developed to predict drug-target interactions, they are either less accurate than the one that we are proposing here or computationally too intensive, thereby limiting their capability for large-scale off-target identification. In addition, the performances of most machine learning based algorithms have been mainly evaluated to predict off-target interactions in the same gene family for hundreds of chemicals. It is not clear how these algorithms perform in terms of detecting off-targets across gene families on a proteome scale. Here, we are presenting a fast and accurate off-target prediction method, REMAP, which is based on a dual regularized one-class collaborative filtering algorithm, to explore continuous chemical space, protein space, and their interactome on a large scale. When tested in a reliable, extensive, and cross-gene family benchmark, REMAP outperforms the state-of-the-art methods. Furthermore, REMAP is highly scalable. It can screen a dataset of 200 thousands chemicals against 20 thousands proteins within 2 hours. Using the reconstructed genome-wide target profile as the fingerprint of a chemical compound, we predicted that seven FDA-approved drugs can be repurposed as novel anti-cancer therapies. The anti-cancer activity of six of them is supported by experimental evidences. Thus, REMAP is a valuable addition to the existing in silico toolbox for drug target identification, drug repurposing, phenotypic screening, and side effect prediction. The software and benchmark are available at https://github.com/hansaimlim/REMAP. PMID:27716836

  17. Transient elastography (FibroScan®) with controlled attenuation parameter in the assessment of liver steatosis and fibrosis in patients with nonalcoholic fatty liver disease - Where do we stand?

    PubMed Central

    Mikolasevic, Ivana; Orlic, Lidija; Franjic, Neven; Hauser, Goran; Stimac, Davor; Milic, Sandra

    2016-01-01

    Non-alcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis (laboratory tests and ultrasonography) or cannot be applied as a screening procedure (liver biopsy). Among the non-invasive tests, transient elastography (FibroScan®, TE) with controlled attenuation parameter (CAP) has demonstrated good accuracy in quantifying the levels of liver steatosis and fibrosis in patients with NAFLD, the factors associated with the diagnosis and NAFLD progression. The method is fast, reliable and reproducible, with good intra- and interobserver levels of agreement, thus allowing for population-wide screening and disease follow-up. The initial inability of the procedure to accurately determine fibrosis and steatosis in obese patients has been addressed with the development of the obese-specific XL probe. TE with CAP is a viable alternative to ultrasonography, both as an initial assessment and during follow-up of patients with NAFLD. Its ability to exclude patients with advanced fibrosis may be used to identify low-risk NAFLD patients in whom liver biopsy is not needed, therefore reducing the risk of complications and the financial costs. PMID:27621571

  18. Catalyst Stability Benchmarking for the Oxygen Evolution Reaction: The Importance of Backing Electrode Material and Dissolution in Accelerated Aging Studies.

    PubMed

    Geiger, Simon; Kasian, Olga; Mingers, Andrea M; Nicley, Shannon S; Haenen, Ken; Mayrhofer, Karl J J; Cherevko, Serhiy

    2017-09-18

    In searching for alternative oxygen evolution reaction (OER) catalysts for acidic water splitting, fast screening of the material intrinsic activity and stability in half-cell tests is of vital importance. The screening process significantly accelerates the discovery of new promising materials without the need of time-consuming real-cell analysis. In commonly employed tests, a conclusion on the catalyst stability is drawn solely on the basis of electrochemical data, for example, by evaluating potential-versus-time profiles. Herein important limitations of such approaches, which are related to the degradation of the backing electrode material, are demonstrated. State-of-the-art Ir-black powder is investigated for OER activity and for dissolution as a function of the backing electrode material. Even at very short time intervals materials like glassy carbon passivate, increasing the contact resistance and concealing the degradation phenomena of the electrocatalyst itself. Alternative backing electrodes like gold and boron-doped diamond show better stability and are thus recommended for short accelerated aging investigations. Moreover, parallel quantification of dissolution products in the electrolyte is shown to be of great importance for comparing OER catalyst feasibility. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Position-sensitive ``movie'' in situ neutron detector for the UCN τ experiment

    NASA Astrophysics Data System (ADS)

    Weaver, Hannah; UCNTau Collaboration

    2016-09-01

    Precision measurements of neutron β-decay parameters provide tests of fundamental theories in elementary particle physics and cosmology such as the Standard Model and Big Bang nucleosynthesis. In particular, the UCN τ experiment aims to measure the mean lifetime of ultracold neutrons confined in an asymmetric magneto-gravitational trap using an in situ neutron detector. This detector consists of a 20 nm film of 10B on top of a ZnS:Ag scintillating screen. The screen is readout using two photomultipliers which view an array of wavelength shifting fibers optically coupled to the scintillator. When the detector is lowered into the loaded trap, light is emitted due to the charged particles recoiling into the ZnS:Ag when neutrons absorb on the 10B. Phase space evolution in the stored neutron population can lead to apparent shifts in the measured neutron lifetime with the detector height. In order to quantify this systematic uncertainty, we are implementing a supplemental 64-channel position-sensitive PMT module with high quantum efficiency and fast time response to image the entire detector in situ during measurements. We have characterized a prototype using a ZnS screen and an α-particle source along with a prototype lens system and will report the results and future plans.

  20. Cyanobacterial Xenobiotics as Evaluated by a Caenorhabditis elegans Neurotoxicity Screening Test

    PubMed Central

    Ju, Jingjuan; Saul, Nadine; Kochan, Cindy; Putschew, Anke; Pu, Yuepu; Yin, Lihong; Steinberg, Christian E. W.

    2014-01-01

    In fresh waters cyanobacterial blooms can produce a variety of toxins, such as microcystin variants (MCs) and anatoxin-a (ANA). ANA is a well-known neurotoxin, whereas MCs are hepatotoxic and, to a lesser degree, also neurotoxic. Neurotoxicity applies especially to invertebrates lacking livers. Current standardized neurotoxicity screening methods use rats or mice. However, in order to minimize vertebrate animal experiments as well as experimental time and effort, many investigators have proposed the nematode Caenorhabditis elegans as an appropriate invertebrate model. Therefore, four known neurotoxic compounds (positive compounds: chlorpyrifos, abamectin, atropine, and acrylamide) were chosen to verify the expected impacts on autonomic (locomotion, feeding, defecation) and sensory (thermal, chemical, and mechanical sensory perception) functions in C. elegans. This study is another step towards successfully establishing C. elegans as an alternative neurotoxicity model. By using this protocol, anatoxin-a adversely affected locomotive behavior and pharyngeal pumping frequency and, most strongly, chemotactic and thermotactic behavior, whereas MC-LR impacted locomotion, pumping, and mechanical behavior, but not chemical sensory behavior. Environmental samples can also be screened in this simple and fast way for neurotoxic characteristics. The filtrate of a Microcystis aeruginosa culture, known for its hepatotoxicity, also displayed mild neurotoxicity (modulated short-term thermotaxis). These results show the suitability of this assay for environmental cyanotoxin-containing samples. PMID:24776722

  1. Ultrafast STR Separations on Short-Channel Microfluidic Systems for Forensic Screening and Genotyping.

    PubMed

    Aboud, Maurice J; Gassmann, Marcus; McCord, Bruce

    2015-09-01

    There are situations in which it is important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. DNA typing methods provide the best biometric information yielding identity, kinship, and geographical origin, but they are not portable and rapid. This study details the development of a portable short-channel microfluidic device based on a modified Agilent 2100 bioanalyzer for applications in forensic genomics. The system utilizes a denaturing polymer matrix with dual-channel laser-induced fluorescence and is capable of producing a genotype in 80 sec. The device was tested for precision and resolution using an allelic ladder created from 6 short tandem repeat (STR) loci and a sex marker (amelogenin). The results demonstrated a precision of 0.09-0.21 bp over the entire size range and resolution values from 2.5 to 4.1 bp. Overall, the results demonstrate the chip provides a portable, rapid, and precise method for screening amplified short tandem repeats and human identification screening. © 2015 American Academy of Forensic Sciences.

  2. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.

    PubMed

    Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-02-01

    Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.

  3. Quantitative digital image analysis of chromogenic assays for high throughput screening of alpha-amylase mutant libraries.

    PubMed

    Shankar, Manoharan; Priyadharshini, Ramachandran; Gunasekaran, Paramasamy

    2009-08-01

    An image analysis-based method for high throughput screening of an alpha-amylase mutant library using chromogenic assays was developed. Assays were performed in microplates and high resolution images of the assay plates were read using the Virtual Microplate Reader (VMR) script to quantify the concentration of the chromogen. This method is fast and sensitive in quantifying 0.025-0.3 mg starch/ml as well as 0.05-0.75 mg glucose/ml. It was also an effective screening method for improved alpha-amylase activity with a coefficient of variance of 18%.

  4. Diagnostic accuracy of a point-of-care urine test for tuberculosis screening among newly-diagnosed HIV-infected adults: a prospective, clinic-based study.

    PubMed

    Drain, Paul K; Losina, Elena; Coleman, Sharon M; Giddy, Janet; Ross, Douglas; Katz, Jeffrey N; Walensky, Rochelle P; Freedberg, Kenneth A; Bassett, Ingrid V

    2014-02-26

    A rapid diagnostic test for active tuberculosis (TB) at the clinical point-of-care could expedite case detection and accelerate TB treatment initiation. We assessed the diagnostic accuracy of a rapid urine lipoarabinomannan (LAM) test for TB screening among HIV-infected adults in a TB-endemic setting. We prospectively enrolled newly-diagnosed HIV-infected adults (≥18 years) at 4 outpatient clinics in Durban from Oct 2011-May 2012, excluding those on TB therapy. A physician evaluated all participants and offered CD4 cell count testing. Trained study nurses collected a sputum sample for acid-fast bacilli smear microscopy (AFB) and mycobacterial culture, and performed urine LAM testing using Determine™ TB LAM in the clinic. The presence of a band regardless of intensity on the urine LAM test was considered positive. We defined as the gold standard for active pulmonary TB a positive sputum culture for Mycobacterium tuberculosis. Diagnostic accuracy of urine LAM was assessed, alone and in combination with smear microscopy, and stratified by CD4 cell count. Among 342 newly-diagnosed HIV-infected participants, 190 (56%) were male, mean age was 35.6 years, and median CD4 was 182/mm3. Sixty participants had culture-positive pulmonary TB, resulting in an estimated prevalence of 17.5% (95% CI 13.7-22.0%). Forty-five (13.2%) participants were urine LAM positive. Mean time from urine specimen collection to LAM test result was 40 minutes (95% CI 34-46 minutes). Urine LAM test sensitivity was 28.3% (95% CI 17.5-41.4) overall, and 37.5% (95% CI 21.1-56.3) for those with CD4 count <100/mm3, while specificity was 90.1% (95% CI 86.0-93.3) overall, and 86.9% (95% CI 75.8-94.2) for those with CD4 < 100/mm3. When combined with sputum AFB (either test positive), sensitivity increased to 38.3% (95% CI 26.0-51.8), but specificity decreased to 85.8% (95% CI 81.1-89.7). In this prospective, clinic-based study with trained nurses, a rapid urine LAM test had low sensitivity for TB screening among newly-diagnosed HIV-infected adults, but improved sensitivity when combined with sputum smear microscopy.

  5. Development of a fast screening and confirmatory method by liquid chromatography-quadrupole-time-of-flight mass spectrometry for glucuronide-conjugated methyltestosterone metabolite in tilapia.

    PubMed

    Amarasinghe, Kande; Chu, Pak-Sin; Evans, Eric; Reimschuessel, Renate; Hasbrouck, Nicholas; Jayasuriya, Hiranthi

    2012-05-23

    This paper describes the development of a fast method to screen and confirm methyltestosterone 17-O-glucuronide (MT-glu) in tilapia bile. The method consists of solid-phase extraction (SPE) followed by high-performance liquid chromatography-mass spectrometry. The system used was an Agilent 6530 Q-TOF with an Agilent Jet stream electrospray ionization interface. The glucuronide detected in the bile was characterized as MT-glu by comparison with a chemically synthesized standard. MT-glu was detected in bile for up to 7 days after dosing. Semiquantification was done with matrix-matched calibration curves, because MT-glu showed signal suppression due to matrix effects. This method provides a suitable tool to monitor the illegal use of methyltestosterone in tilapia culture.

  6. Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges.

    PubMed

    Kolosova, Anna Yu; Sibanda, Liberty; Dumoulin, Frédéric; Lewis, Janet; Duveiller, Etienne; Van Peteghem, Carlos; De Saeger, Sarah

    2008-06-02

    A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 microg kg(-1) were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities.

  7. Non-animal photosafety assessment approaches for cosmetics based on the photochemical and photobiochemical properties.

    PubMed

    Onoue, Satomi; Suzuki, Gen; Kato, Masashi; Hirota, Morihiko; Nishida, Hayato; Kitagaki, Masato; Kouzuki, Hirokazu; Yamada, Shizuo

    2013-12-01

    The main purpose of the present study was to establish a non-animal photosafety assessment approach for cosmetics using in vitro photochemical and photobiochemical screening systems. Fifty-one cosmetics, pharmaceutics and other chemicals were selected as model chemicals on the basis of animal and/or clinical photosafety information. The model chemicals were assessed in terms of photochemical properties by UV/VIS spectral analysis, reactive oxygen species (ROS) assay and 3T3 neutral red uptake phototoxicity testing (3T3 NRU PT). Most phototoxins exhibited potent UV/VIS absorption with molar extinction coefficients of over 1000M(-1)cm(-1), although false-negative prediction occurred for 2 cosmetic phototoxins owing to weak UV/VIS absorption. Among all the cosmetic ingredients, ca. 42% of tested chemicals were non-testable in the ROS assay because of low water solubility; thereby, micellar ROS (mROS) assay using a solubilizing surfactant was employed for follow-up screening. Upon combination use of ROS and mROS assays, the individual specificity was 88.2%, and the positive and negative predictivities were estimated to be 94.4% and 100%, respectively. In the 3T3 NRU PT, 3 cosmetics and 4 drugs were incorrectly predicted not to be phototoxic, although some of them were typical photoallergens. Thus, these in vitro screening systems individually provide false predictions; however, a systematic tiered approach using these assays could provide reliable photosafety assessment without any false-negatives. The combined use of in vitro assays might enable simple and fast non-animal photosafety evaluation of cosmetic ingredients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Usability of digital media in patients with COPD: a pilot study.

    PubMed

    Cheung, Amy; Janssen, Anton; Amft, Oliver; Wouters, Emiel F M; Spruit, Martijn A

    2013-04-01

    Digital media can be integrated in tele-monitoring solutions, serving as the main interface between the patient and the caregiver. Consequently, the selection of the most appropriate digital medium for the specified target group is critical to ensure compliance with the tele-monitoring system. This pilot study aims to gather insights from patients with chronic obstructive pulmonary disease (COPD) on the ease-of-use, efficacy, effectiveness, and satisfaction of different types of digital media. Five off-the-shelf digital media devices were tested on nine patients at CIRO+ in Horn, The Netherlands. Usability was evaluated by asking patients to use each device to answer questions related to their symptoms and health status. Subsequently, patients completed a paper-based device usability questionnaire, which assessed prior experience with digital media, device dimensions, device controllability, response speed, screen readability, ease-of-use, and overall satisfaction. After testing all the devices, patients ranked the devices according to their preference. We identified the netbook as the preferred type of device due to its good controllability, fast response time, and large screen size. The smartphone was the least favorite device as patients found the size of the screen to be too small, which made it difficult to interact with. The pilot study has provided important insights to guide the selection of the most appropriate type of digital medium for implementation in tele-monitoring solutions for patients with COPD. As the digital medium is an important interface to the patient in tele-monitoring solutions, it is essential that patients feel motivated to interact with the digital medium on a regular basis.

  9. How to report and interpret screening test properties: guidelines for driving researchers.

    PubMed

    Weaver, Bruce; Walter, Stephen D; Bédard, Michel

    2014-01-01

    One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.

  10. The yield and feasibility of integrated screening for TB, diabetes and HIV in four public hospitals in Ethiopia.

    PubMed

    Jerene, Degu; Hiruy, Nebiyu; Jemal, Ilili; Gebrekiros, Wondimu; Anteneh, Tadesse; Habte, Dereje; Melese, Muluken; Suarez, Pedro; Sangiwa, Gloria

    2017-03-01

    Our objective was to demonstrate the feasibility of integrated care for TB, HIV and diabetes mellitus (DM) in a pilot project in Ethiopia. Healthcare workers in four hospitals screened patients with TB for HIV and DM; patients with HIV for DM and TB; and patients with DM for TB. Fasting and random plasma glucose (RPG) tests were used to confirm the diagnosis of DM. We used screening checklists for TB and DM, and additional risk scoring criteria to identify patients at risk of DM. Of 3439 study participants, 888 were patients with DM, 439 patients with TB and 2112 from HIV clinics. Six of the patients with DM had TB of whom five were already on treatment; and 141 (32.4%) patients with TB had DM, of whom only five were previously diagnosed with DM. Symptomatic patients and those with a risk score of 5 or more were about three times more likely to have abnormal blood glucose level. Of 2075 HIV patients with RPG determined, only 31 (1.5%) had abnormal RPG. Tri-directional screening was feasible for detecting and managing previously undiagnosed TB and DM. More work is needed to better understand the interaction between HIV and DM. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Physicomechanical characterization of the extrusion-spheronization process. I. Instrumentation of the extruder.

    PubMed

    Shah, R D; Kabadi, M; Pope, D G; Augsburger, L L

    1994-03-01

    Extrusion-spheronization is a popular means of producing spheres which can be coated to form a controlled-release system. In the extrusion process, stress is necessary to force a wet mass through small orifices, and as a result, frictional heat builds up at the screen. Therefore, the quantitative measurement of the screen pressure and screen temperature is described and shown to provide objective measures of extrudability. A strain gauge load cell was mounted tangentially to the screen of a Luwa EXDS-60 extruder with a specifically fabricated holder. The load cell output was calibrated in terms of pressure inside the screen with a special rubber plug system. A fast-response thermocouple was used to measure the screen temperature. Experiments with 50/50 lactose/Avicel PH101 revealed that a linear relationship exists between the amount of water used in the granulation and the screen pressure, that the percentage open area of the screen determines the rank order of the screen pressure, and that the maximal yield of 18/25-mesh cut pellets was uniquely related to the screen pressure. Also, a high degree of correlation was observed between the screen pressure and the screen temperature.

  12. Differences in Mucociliary activity of volunteers undergoing Ramadan versus Nineveh fasting.

    PubMed

    Develioglu, Omer Necati; Sirazi, Sait; Topak, Murat; Purisa, Sevim; Kulekci, Mehmet

    2013-05-01

    This study, aimed to evaluate the difference in mucociliary clearance among volunteers who underwent Ramadan versus Nineveh fasting regimens as well as the difference between the fasting period and 4 weeks following the fasting period in both groups. In this study, two different fasting groups were established: Ramadan (fasting for an average of 15 h for 29 consecutive days, n = 40) and Nineveh (60 h of nonstop fasting, n = 26). Subjects in each group underwent saccharin testing twice: at the end of the fasting period prior to resumption of eating and at 4 weeks after the end of Ramadan or Nineveh fasting. Statistical analysis was performed using the Mann-Whitney U-test, Wilcoxon, Chi-square, and paired t test. A p value less than 0.05 was considered statistically significant. Forty subjects who underwent Ramadan fasting and 26 subjects who underwent Nineveh fasting were included in this study. Of the 66 study participants, 34 (51.5 %) were men and 32 (48.5 %) were women. Their median age was 31 years (range 17-70 years) for Nineveh fasting subjects and 40 years (range 17-70 years) for Ramadan fasting subjects. Chi-square tests revealed no significant difference between the Ramadan and Nineveh fasting groups in gender (p = 0.418), and the Mann-Whitney U-test showed no difference in age. A statistically significant difference was found in the mucociliary clearance time between the Nineveh fasting and non-fasting periods (p = 0.013). Using Wilcoxon signed-rank tests, we found no significant difference in the mucociliary clearance time between the Ramadan fasting and control (4 weeks after the fasting period) periods (p = 0.121). The percentage difference between the fasting and control periods was similar between groups and was not statistically significant for the Ramadan and Nineveh fasting groups (p = 0.086). The results of the present study indicated that long-term fasting with hypohydration contributed to the deterioration of nasal mucociliary clearance. Our data indicate that optimal hydration, sleep patterns, and fasting times contribute to proper mucociliary clearance.

  13. Predictive value of first fasting plasma glucose compared with admission plasma glucose for undiagnosed diabetes in a stable cardiology population.

    PubMed

    Wen, Zhu-zhi; Zhang, Xin-mei; Mai, Zun; Geng, Deng-feng; Wang, Jing-feng

    2012-09-01

    The study compared the predictive value of admission plasma glucose (APG) and first fasting plasma glucose (FPG) in stratifying patients meriting an oral glucose tolerance test (OGTT). Characteristics of APG, FPG and OGTT 2-hour glucose as well as other blood measurements, physical examinations and medical information were assessed in 994 patients without known diabetes. The prevalences of diabetes and impaired glucose tolerance were 24.6% and 37.9%, according to an OGTT, respectively. The first FPG demonstrated stronger predictive value in diagnosing diabetes than APG did both in overall and in patients with less clinical value. Compared to the first FPG, APG provided less value to coronary artery disease, hypertension and high-sensitivity C-reactive protein for diabetes screening. The first FPG exerted more predictive value than APG did and was still a preferable reference prior to APG in stratifying patients for undiagnosed diabetes by an OGTT. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Prevalence of Diabetes and Intermediate Hyperglycemia Among Adults From the First Multinational Study of Noncommunicable Diseases in Six Central American Countries

    PubMed Central

    Barcelo, Alberto; Gregg, Edward W.; Gerzoff, Robert B.; Wong, Roy; Perez Flores, Enrique; Ramirez-Zea, Manuel; Cafiero, Elizabeth; Altamirano, Lesbia; Ascencio Rivera, Melanie; de Cosio, Gerardo; de Maza, Martha Dinorah; del Aguila, Roberto; Emanuel, Englebert; Gil, Enrique; Gough, Ethan; Jenkins, Valerie; Orellana, Patrícia; Palma, Ruben; Palomo, Ruben; Pastora, Martha; Peña, Rodolfo; Pineda, Elia; Rodriguez, Bismark; Tacsan, Luis; Thompson, Loraine; Villagra, Lucy

    2012-01-01

    OBJECTIVE The increasing burdens of obesity and diabetes are two of the most prominent threats to the health of populations of developed and developing countries alike. The Central America Diabetes Initiative (CAMDI) is the first study to examine the prevalence of diabetes in Central America. RESEARCH DESIGN AND METHODS The CAMDI survey was a cross-sectional survey based on a probabilistic sample of the noninstitutionalized population of five Central American populations conducted between 2003 and 2006. The total sample population was 10,822, of whom 7,234 (67%) underwent anthropometry measurement and a fasting blood glucose or 2-h oral glucose tolerance test. RESULTS The total prevalence of diabetes was 8.5%, but was higher in Belize (12.9%) and lower in Honduras (5.4%). Of the screened population, 18.6% had impaired glucose tolerance/impaired fasting glucose. CONCLUSIONS As this population ages, the prevalence of diabetes is likely to continue to rise in a dramatic and devastating manner. Preventive strategies must be quickly introduced. PMID:22323417

  15. Hybrid MPI/OpenMP Implementation of the ORAC Molecular Dynamics Program for Generalized Ensemble and Fast Switching Alchemical Simulations.

    PubMed

    Procacci, Piero

    2016-06-27

    We present a new release (6.0β) of the ORAC program [Marsili et al. J. Comput. Chem. 2010, 31, 1106-1116] with a hybrid OpenMP/MPI (open multiprocessing message passing interface) multilevel parallelism tailored for generalized ensemble (GE) and fast switching double annihilation (FS-DAM) nonequilibrium technology aimed at evaluating the binding free energy in drug-receptor system on high performance computing platforms. The production of the GE or FS-DAM trajectories is handled using a weak scaling parallel approach on the MPI level only, while a strong scaling force decomposition scheme is implemented for intranode computations with shared memory access at the OpenMP level. The efficiency, simplicity, and inherent parallel nature of the ORAC implementation of the FS-DAM algorithm, project the code as a possible effective tool for a second generation high throughput virtual screening in drug discovery and design. The code, along with documentation, testing, and ancillary tools, is distributed under the provisions of the General Public License and can be freely downloaded at www.chim.unifi.it/orac .

  16. Screening douglas-fir for rapid early growth in common-garden tests in spain. Forest Service general technical report (Final)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, G.T.; Alonso, G.V.; Arribas, G.P.

    1993-08-01

    Douglas-firs from 91 seed sources in North America were evaluated after 5 and 6 years in 15 common-garden tests in the mountainous regions of northwest and north central Spain. Analyses of tallest trees showed that most of the sources of highest potential for reforestation in Spain are found in regions where the Pacific Ocean air mass dominates climate. Fast growers came from coastal slopes of the Coast Ranges from northwest California to the Georgia Strait of southwest British Columbia and inland slopes of the Olympic Mountains and Coast and Cascade Ranges facing the Puget Trough in western Washington and Willamettemore » Valley in northwest Oregon. Slow growers came from latitudes south of 44 deg and north of 50 deg, high altitudes west of the crest of the Cascade Ranges, and regions east of the crest where the continental air mass dominated climate.« less

  17. Utility of Brief Versions of the Alcohol Use Disorders Identification Test (AUDIT) to Identify Excessive Drinking Among Patients in HIV Care in South Africa.

    PubMed

    Morojele, Neo K; Nkosi, Sebenzile; Kekwaletswe, Connie T; Shuper, Paul A; Manda, Samuel O; Myers, Bronwyn; Parry, Charles D H

    2017-01-01

    In sub-Saharan Africa, large proportions of patients who are on antiretroviral therapy (ART) engage in excessive alcohol use, which may lead to adverse health consequences and may go undetected. Consequently, health care workers need brief screening tools to be able to routinely identify and manage excessive alcohol use among their patients. Various brief versions of the valid and reliable 10-item Alcohol Use Disorders Identification Test (AUDIT) (i.e., the AUDIT-C, AUDIT-3, AUDIT-QF, AUDIT-PC, AUDIT-4, and m-FAST) may potentially replace the full AUDIT in busy HIV care settings. This study aims to assess the utility of these six brief versions of the AUDIT relative to the full AUDIT for identifying excessive alcohol use among patients in HIV care settings in South Africa. Participants were 188 (95 women) patients from three ART clinics within district hospitals in the City of Tshwane Metropolitan Municipality who reported past-12-month alcohol use. Performance of each brief AUDIT measure for identifying excessive alcohol use was evaluated against that of the full AUDIT (with a cutoff score of ≥6 for women and ≥8 for men) as the gold standard. We used receiver-operating characteristic (ROC) analysis. Most brief AUDIT measures had an area under the receiver operating curve (AUROC) above .90 when compared with the full AUDIT (five of six for women and three of six for men). The AUDIT-PC, AUDIT-4, and m-FAST had the highest AUROCs, whereas the three brief measures comprising only consumption items had low specificities at the most optimal cutoff levels. Various brief versions of the AUDIT may be appropriate substitutes for the full AUDIT for screening for excessive alcohol use in HIV clinics in sub-Saharan Africa.

  18. Obstructive sleep apnea syndrome causes a pseudo-Cushing's state in Japanese obese patients with type 2 diabetes mellitus.

    PubMed

    Tamada, Daisuke; Otsuki, Michio; Kashine, Susumu; Hirata, Ayumu; Onodera, Toshiharu; Kitamura, Tetsuhiro; Shimomura, Iichiro

    2013-01-01

    Activation of the hypothalamic-pituitary-adrenal axis has been reported in some patients with the obstructive sleep apnea syndrome (OSAS). In current study, we investigated whether OSAS affect the screening test for subclinical Cushing's disease using 0.5 mg overnight dexamethasone suppression test (DST) in Japanese obese diabetic patients with OSAS. Among Japanese obese patients with type 2 diabetes mellitus who had been hospitalized in our department, we selected 20 patients with moderate to severe untreated OSAS (apnea-hypoxia index, AHI, of ≥15 events/hour). All patients underwent 0.5 mg DST. The same test was repeated in patients with positive response of it within a few days after continuous positive airway pressure (CPAP) therapy. We found that five patients showed positive response of DST (25%). Three of these patients continued to use CPAP, and they showed normal response of DST after CPAP therapy. Serum cortisol after 0.5 mg DST measured before CPAP therapy correlated significantly with fasting serum cortisol level (r=0.764, p<0.0001), but not with various clinical parameters, including AHI (p=0.784), body mass index (p=0.984), waist circumference (p=0.957), HbA1c (p=0.261), fasting plasma glucose (p=0.420) and HOMA-IR (p=0.500). Our study show that OSAS causes a pseudo-Cushing's syndrome in obese patients with type 2 diabetes mellitus, which phenomena can be reversed by CPAP therapy.

  19. To Screen or Not to Screen? The Benefits and Harms of Screening Tests

    MedlinePlus

    ... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...

  20. Screening and brief interventions for hazardous alcohol use in accident and emergency departments: a randomised controlled trial protocol

    PubMed Central

    Coulton, Simon; Perryman, Katherine; Bland, Martin; Cassidy, Paul; Crawford, Mike; Deluca, Paolo; Drummond, Colin; Gilvarry, Eilish; Godfrey, Christine; Heather, Nick; Kaner, Eileen; Myles, Judy; Newbury-Birch, Dorothy; Oyefeso, Adenekan; Parrott, Steve; Phillips, Tom; Shenker, Don; Shepherd, Jonathan

    2009-01-01

    Background There is a wealth of evidence regarding the detrimental impact of excessive alcohol consumption on the physical, psychological and social health of the population. There also exists a substantial evidence base for the efficacy of brief interventions aimed at reducing alcohol consumption across a range of healthcare settings. Primary research conducted in emergency departments has reinforced the current evidence regarding the potential effectiveness and cost-effectiveness. Within this body of evidence there is marked variation in the intensity of brief intervention delivered, from very minimal interventions to more intensive behavioural or lifestyle counselling approaches. Further the majority of primary research has been conducted in single centre and there is little evidence of the wider issues of generalisability and implementation of brief interventions across emergency departments. Methods/design The study design is a prospective pragmatic factorial cluster randomised controlled trial. Individual Emergency Departments (ED) (n = 9) are randomised with equal probability to a combination of screening tool (M-SASQ vs FAST vs SIPS-PAT) and an intervention (Minimal intervention vs Brief advice vs Brief lifestyle counselling). The primary hypothesis is that brief lifestyle counselling delivered by an Alcohol Health Worker (AHW) is more effective than Brief Advice or a minimal intervention delivered by ED staff. Secondary hypotheses address whether short screening instruments are more acceptable and as efficient as longer screening instruments and the cost-effectiveness of screening and brief interventions in ED. Individual participants will be followed up at 6 and 12 months after consent. The primary outcome measure is performance using a gold-standard screening test (AUDIT). Secondary outcomes include; quantity and frequency of alcohol consumed, alcohol-related problems, motivation to change, health related quality of life and service utilisation. Discussion This paper presents a protocol for a large multi-centre pragmatic factorial cluster randomised trial to evaluate the effectiveness and cost-effectiveness of screening and brief interventions for hazardous alcohol users attending emergency departments. Trial Registration ISRCTN 93681536 PMID:19575791

  1. A Scoping Review of Behavioral Economic Interventions for Prevention and Treatment of Type 2 Diabetes Mellitus.

    PubMed

    Kullgren, Jeffrey T; Hafez, Dina; Fedewa, Allison; Heisler, Michele

    2017-09-01

    The purpose of this paper was to review studies of behavioral economic interventions (financial incentives, choice architecture modifications, or commitment devices) to prevent type 2 diabetes mellitus (T2DM) among at-risk patients or improve self-management among patients with T2DM. We found 15 studies that used varied study designs and outcomes to test behavioral economic interventions in clinical, workplace, or health plan settings. Of four studies that focused on prevention of T2DM, two found that financial incentives increased weight loss and completion of a fasting blood glucose test, and two choice architecture modifications had mixed effects in encouraging completion of tests to screen for T2DM. Of 11 studies that focused on improving self-management of T2DM, four of six tests of financial incentives demonstrated increased engagement in recommended care processes or improved biometric measures, and three of five tests of choice architecture modifications found improvements in self-management behaviors. Though few studies have tested behavioral economic interventions for prevention or treatment of T2DM, those that have suggested such approaches have the potential to improve patient behaviors and such approaches should be tested more broadly.

  2. Comparison of susceptibility test methods to detect penicillin susceptibility in Streptococcus pneumoniae isolates.

    PubMed

    Mohd Nasir, Mohd Desa; Parasakthi, Navaratnam

    2004-06-01

    The increasing prevalence of penicillin-resistant Streptococuus pneumoniae urges for fast and accurate susceptibility testing methods. This study evaluated the comparability of three commonly used techniques; disk diffusion, E-test and agar dilution, to detect penicillin susceptibility in clinical isolates of S. pneumoniae. Fifty pneumococcal isolates, obtained from patients at the University of Malaya Medical Centre, were selected to include both penicillin-susceptible strains and those that had decreased susceptibility (resistant and intermediate) to penicillin. The minimum inhibitory concentration (MIC) values of penicillin to serve as the reference was determined by the agar dilution method in which, based on the MIC breakpoints recommended by the National Committee for Clinical Laboratory Standards (NCCLS), 27 strains had decreased susceptibility to penicillin with 17 strains resistant and 10 intermediate. Comparing to the agar dilution method, oxacillin disk diffusion test detected all strains with decreased penicillin susceptibility as such while E-test showed a close agreement of susceptibility (92%) of the isolates to penicillin. This confirmed that oxacillin is a good screening test for S. pneumoniae isolates with decreased susceptibility to penicillin while E-test is very reliable for rapid and accurate detection of penicillin susceptibility.

  3. A Scoping Review of Behavioral Economic Interventions for Prevention and Treatment of Type 2 Diabetes Mellitus

    PubMed Central

    Kullgren, Jeffrey T.; Hafez, Dina; Fedewa, Allison; Heisler, Michele

    2017-01-01

    Purpose of review To review studies of behavioral economic interventions (financial incentives, choice architecture modifications, or commitment devices) to prevent type 2 diabetes mellitus (T2DM) among at-risk patients or improve self-management among patients with T2DM. Recent findings We found 15 studies that used varied study designs and outcomes to test behavioral economic interventions in clinical, workplace, or health plan settings. Of four studies that focused on prevention of T2DM, two found that financial incentives increased weight loss and completion of a fasting blood glucose test, and two choice architecture modifications had mixed effects in encouraging completion of tests to screen for T2DM. Of 11 studies that focused on improving self-management of T2DM, four of six tests of financial incentives demonstrated increased engagement in recommended care processes or improved biometric measures, and three of five tests of choice architecture modifications found improvements in self-management behaviors. Summary Though few studies have tested behavioral economic interventions for prevention or treatment of T2DM, those that have suggest such approaches have potential to improve patient behaviors and should be tested more broadly. PMID:28755061

  4. Evaluation of Visual Alerts in the Maritime Domain. Study 2. Program Modifications

    DTIC Science & Technology

    2009-02-01

    feedback that they were wrong, and without consulting the Status screen again enter the alternate answer (“ qwe ”). That is, the need to consult the...Neutral Large Slow No QWE Hostile Small Fast Yes ASD DRDC Atlantic CR 2008-268 5 Table 3. First proposed target types and...classification scheme. Target Size Speed Weapons Flag Response Type Neutral Large Slow No Other QWE Hostile Small Fast Yes Other ASD Friendly Large/Small Slow

  5. Sulfadiazine-selective determination in aquaculture environment: selective potentiometric transduction by neutral or charged ionophores.

    PubMed

    Almeida, S A A; Heitor, A M; Montenegro, M C B S M; Sales, M G F

    2011-09-15

    Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade(-1) and detection limits of 3.91×10(-5) mol L(-1). The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7-62.0 mV decade(-1) and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2-7. The sensors displayed fast response, always <15s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Study Protocol: The Norfolk Diabetes Prevention Study [NDPS]: a 46 month multi - centre, randomised, controlled parallel group trial of a lifestyle intervention [with or without additional support from lay lifestyle mentors with Type 2 diabetes] to prevent transition to Type 2 diabetes in high risk groups with non - diabetic hyperglycaemia, or impaired fasting glucose.

    PubMed

    Pascale, Melanie; Murray, Nikki; Bachmann, Max; Barton, Garry; Clark, Allan; Howe, Amanda; Greaves, Colin; Sampson, Mike

    2017-01-06

    This 7 year NIHR programme [2011-2018] tests the primary hypothesis that the NDPS diet and physical activity intervention will reduce the risk of transition to type 2 diabetes (T2DM) in groups at high risk of Type 2 diabetes. The NDPS programme recognizes the need to reduce intervention costs through group delivery and the use of lay mentors with T2DM, the realities of normal primary care, and the complexity of the current glycaemic categorisation of T2DM risk. NDPS identifies people at highest risk of T2DM on the databases of 135 general practices in the East of England for further screening with ab fasting plasma glucose and glycosylated haemoglobin [HbA1c]. Those with an elevated fasting plasma glucose [impaired fasting glucose or IFG] with or without an elevated HbA1c [non -diabetic hyperglycaemia; NDH] are randomised into three treatment arms: a control arm receiving no trial intervention, an arm receiving an intensive bespoke group-based diet and physical activity intervention, and an arm receiving the same intervention with enhanced support from people with T2DM trained as diabetes prevention mentors [DPM]. The primary end point is cumulative transition rates to T2DM between the two intervention groups, and between each intervention group and the control group at 46 months. Participants with screen detected T2DM are randomized into an equivalent prospective controlled trial with the same intervention and control arms with glycaemic control [HbA1c] at 46 months as the primary end point. Participants with NDH and a normal fasting plasma glucose are randomised into an equivalent prospective controlled intervention trial with follow up for 40 months. The intervention comprises six education sessions for the first 12 weeks and then up to 15 maintenance sessions until intervention end, all delivered in groups, with additional support from a DPM in one treatment arm. The NDPS programme reports in 2018 and will provide trial outcome data for a group delivered diabetes prevention intervention, supported by lay mentors with T2DM, with intervention in multiple at risk glycaemic categories, and that takes into account the realities of normal clinical practice. ISRCTN34805606 (Retrospectively registered 16.3.16).

  7. [The relationship between executive functions, physical and functional capability in people over 60 years old].

    PubMed

    Rajtar-Zembaty, Anna; Sałakowski, Andrzej; Rajtar-Zembaty, Jakub

    Nowadays it is believed that cognitive decline may contribute to the formation of gait disturbance and increased risk of falls. Currently the importance of executive functions to maintain proper control of gait is emphasized. The aim of the study was to assess the relationship between the level of executive function, functional and physical capability in patients over 60 years of age. The study included 300 patients (199 women and 101 men) aged 60-88 years. In order to screening for cognitive function Mini-Mental State Examination (MMSE) was used. The following researchers tools were used to conduct functional assessment: a) Short Physical Performance Battery (SPPB), b) Timed “Up and Go” (TUG) and c) Fast Walking Test. To assess executive fucntion Trail Making Test (TMT) was selected. The relationship between the speed of information processing (part A, TMT), executive functions (Part B, TMT), level of functional and physical capability was observed. The strongest positive correlation was noted between the time of TUG test and TMT part B (r=0.32; p<0.01), and also between Fast Gait Test and TMT part A (r=0.27; p<0.01). It has been proven that the level of executive function is related to the level of functional capability (β=0.18; p=0.001). It was found that 15% of variation in the level of the TUG test was explained by age, TMT- B, GDS and BMI. There is a relationship between level of executive functions, functional and physical capability in patients over 60 years of age. Cognitive processes play an important role in the control of motor functions therefore it is important to incorporate examination of cognitive functions in the early geriatric diagnosis.

  8. A Policy Analysis on the Proactive Prevention of Chronic Disease: Learnings from the Initial Implementation of Integrated Measurement for Early Detection (MIDO).

    PubMed

    Tapia-Conyer, Roberto; Saucedo-Martínez, Rodrigo; Mújica-Rosales, Ricardo; Gallardo-Rincón, Héctor; Lee, Evan; Waugh, Craig; Guajardo, Lucía; Torres-Beltrán, Braulio; Quijano-González, Úrsula; López-Mendez, Mauricio; Atkinson, Elena Rose

    2017-02-20

    Mexico, like many low- and middle-income countries (LMICs), faces an epidemic of chronic non-communicable diseases (NCDs), specifically diabetes, hypertension, obesity, and lipid disorders. Many people with these NCDs may not be aware that they have a disease, pointing to the need for broader screening programs. The traditional prevention policy in Mexico was based on screening with a paper-based risk factor questionnaire. However, this was used to screen patients already seeking healthcare services at facilities, and screening goals were set as a function of the number of questionnaires applied, not number of individuals screened. Due to this, Fundación Carlos Slim developed Medición Integrada para la Detección Oportuna (MIDOTM), or Integrated Measurement for Early Detection, an NCD screening and proactive prevention policy. This document is a policy analysis based on early learnings from the initial implementation of MIDO in eight primary healthcare centers in two central Mexican states. MIDO was found to expand screening programs beyond clinic walls, systematize community screening strategies, emphasize the detection of pre-disease phases, incorporate lifestyle counseling, and propose screening goals based on population targets. In collaboration with the Mexican Ministry of Health, MIDO has successfully screened over 500 000 individuals-about 40% of whom would not have been screened under previous policies. Of these more than 500 000 screened individuals, 13.4% had pre-diabetes (fasting glucose between 100 and 125 mg/dL), and 5.8% had undiagnosed diabetes (defined as fasting glucose above 126 mg/dL or random glucose above 200 mg/dL). However, there is still room for improvement in linking positive results from screening with disease confirmation and with patient incorporation into disease management. The experience of implementing MIDO in Mexico suggests that primary and secondary prevention programs in other parts of the world should consider the need for population-based screening targets, a greater focus on pre-disease stages, and the streamlining of the transition between screening, confirmation of diagnosis, and incorporation of patients into the healthcare system. © 2017 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  9. Solubility prediction, solvate and cocrystal screening as tools for rational crystal engineering.

    PubMed

    Loschen, Christoph; Klamt, Andreas

    2015-06-01

    The fact that novel drug candidates are becoming increasingly insoluble is a major problem of current drug development. Computational tools may address this issue by screening for suitable solvents or by identifying potential novel cocrystal formers that increase bioavailability. In contrast to other more specialized methods, the fluid phase thermodynamics approach COSMO-RS (conductor-like screening model for real solvents) allows for a comprehensive treatment of drug solubility, solvate and cocrystal formation and many other thermodynamics properties in liquids. This article gives an overview of recent COSMO-RS developments that are of interest for drug development and contains several new application examples for solubility prediction and solvate/cocrystal screening. For all property predictions COSMO-RS has been used. The basic concept of COSMO-RS consists of using the screening charge density as computed from first principles calculations in combination with fast statistical thermodynamics to compute the chemical potential of a compound in solution. The fast and accurate assessment of drug solubility and the identification of suitable solvents, solvate or cocrystal formers is nowadays possible and may be used to complement modern drug development. Efficiency is increased by avoiding costly quantum-chemical computations using a database of previously computed molecular fragments. COSMO-RS theory can be applied to a range of physico-chemical properties, which are of interest in rational crystal engineering. Most notably, in combination with experimental reference data, accurate quantitative solubility predictions in any solvent or solvent mixture are possible. Additionally, COSMO-RS can be extended to the prediction of cocrystal formation, which results in considerable predictive accuracy concerning coformer screening. In a recent variant costly quantum chemical calculations are avoided resulting in a significant speed-up and ease-of-use. © 2015 Royal Pharmaceutical Society.

  10. Clinical expression of haemochromatosis in Irish C282Y homozygotes identified through family screening.

    PubMed

    Gleeson, F; Ryan, E; Barrett, S; Crowe, J

    2004-09-01

    In Ireland, the homozygote frequency of the C282Y mutation in the HFE gene is 1/83. The biochemical expression of this mutation is high in haemochromatosis (HH) individuals identified through family screening, but the clinical expression of the mutation in Irish HH subjects to date has not been investigated fully. To determine the clinical, biochemical and histological penetrance of the C282Y mutation in Irish C282Y homozygotes identified through family screening. Two hundred and nine C282Y homozygous individuals comprising of 172 first-degree relatives, 31 second-degree relatives and four unrelated individuals were identified following HFE mutation analysis of 167 families. The following variables were analysed: age at identification, gender, fasting transferrin saturation, fasting serum ferritin, liver enzymes, clinical symptomatology, liver histopathology and histochemical iron staining. An elevated transferrin saturation in combination with an elevated ferritin was present in 43.4% of males and 23.3% of females. Abnormal liver enzymes were found in 32.3% of males. Diabetes, a haemochromatosis-specific association, was noted in 2.8% of males. Of those individuals requiring liver histopathology evaluation, 38% had moderate-to-severe iron staining, and 42% had fibrosis; 2.8% of the biopsied cohort had cirrhosis. Thus, HH cirrhotics were identified in less than 1% of the screened population. Although the homozygote frequency in Ireland is very high, the prevalence of advanced liver disease was less than 1% of the family members screened. Nevertheless, 42% of biopsied patients had histological evidence of iron overload-related architectural change and 2.8% had cirrhosis. This cohort of young people had previously unrecognized biochemical iron overload and histopathological change. This emphasizes the importance and value of both genetic and biochemical screening in first-degree relatives of identified homozygotes.

  11. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment

    PubMed Central

    Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-01-01

    Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624

  12. Fast-responder: Rapid mobile-phone access to recent remote sensing imagery for first responders

    NASA Astrophysics Data System (ADS)

    Talbot, L. M.; Talbot, B. G.

    We introduce Fast-Responder, a novel prototype data-dissemination application and architecture concept to rapidly deliver remote sensing imagery to smartphones to enable situational awareness. The architecture implements a Fast-Earth image caching system on the phone and interacts with a Fast-Earth server. Prototype evaluation successfully demonstrated that National Guard users could select a location, download multiple remote sensing images, and flicker between images, all in less than a minute on a 3G mobile commercial link. The Fast-Responder architecture is a significant advance that is designed to meet the needs of mobile users, such as National Guard response units, to rapidly access information during a crisis, such as a natural or man-made disaster. This paper focuses on the architecture design and advanced user interface concepts for small-screens for highly active mobile users. Novel Fast-Responder concepts can also enable rapid dissemination and evaluation of imagery on the desktop, opening new technology horizons for both desktop and mobile users.

  13. Ultrastructure and morphology of biofilms on thermoplastic orthodontic appliances in 'fast' and 'slow' plaque formers.

    PubMed

    Low, Bernard; Lee, Wilson; Seneviratne, C J; Samaranayake, Lakshman P; Hägg, Urban

    2011-10-01

    The aim of this study was to investigate the morphological features and distribution of biofilms on Invisalign orthodontic appliances, in a sample of 'slow' and 'fast' plaque formers using scanning electron microscopy (SEM). Fifty-six Chinese male/female volunteers (aged 19-39 years) were screened for their plaque-forming rate using the plaque percentage index (PPI) coupled with digital photography and computer-based image analysis, after a period of 48 hours of abstinence from oral hygiene procedures. Eleven volunteers (seven males/four females) representing the lowest and highest ends of the plaque formation spectrum were chosen as slow and fast plaque formers, respectively. The subjects wore a full-coverage splint appliance, in which four tiles of Invisalign material were embedded. These tiles were collected at intervals of 1, 3, 6, 12, 24, and 48 hours, as well as 3, 7, and 14 days, immediately fixed in 10 per cent paraformaldehyde in 0.2 M cacodylate buffer solution and prepared for SEM. The surface configuration of the Invisalign appliance was visualized, as well as the chronological pattern of biofilm formation. Significance between fast and slow plaque formers was determined using a Student's t-test. Colonization appeared to centre initially on the raised edges or textured surfaces of the appliance, and initial adhesion was quicker and more abundant in the fast plaque-forming group. In the later stages of biofilm development, both groups showed no discernible differences in biofilm accrual on the surfaces, but the fast group displayed a more complex biofilm structure. More recessed and sheltered areas of the appliance, such as the cusp tips and attachment dimples, harboured more biofilm than the flat surfaces. Hence, it seems that the novel Invisialign orthodontic appliance is a useful tool to investigate the features of biofilm formation in time-course studies.

  14. The Effect of Fasting Duration on Baseline Blood Glucose Concentration, Blood Insulin Concentration, Glucose/Insulin Ratio, Oral Sugar Test, and Insulin Response Test Results in Horses.

    PubMed

    Bertin, F R; Taylor, S D; Bianco, A W; Sojka-Kritchevsky, J E

    2016-09-01

    Published descriptions of the oral sugar test (OST) and insulin response test (IRT) have been inconsistent when specifying the protocol for fasting horses before testing. The purpose of our study was to examine the effect of fasting duration on blood glucose concentration, blood insulin concentration, glucose/insulin ratio, OST, and IRT results in horses. Ten healthy adult horses. Both OST and IRT were performed on horses without fasting and after fasting for 3, 6, and 12 hours. Thus, 8 tests were performed per horse in a randomized order. Blood collected at the initial time point of the OST was analysed for both blood glucose and serum insulin concentrations so that baseline concentrations and the glucose/insulin ratio could be determined. Unless fasted, horses had free-choice access to grass hay. There was no effect of fasting and fasting duration on blood glucose concentration, serum insulin concentration, glucose/insulin ratio, or the OST. Response to insulin in the IRT was decreased in fasted horses. The effect increased with fasting duration, with the least response to insulin administration after a 12-hour fast. These data indicate that insulin sensitivity is not a fixed trait in horses. Fasting a horse is not recommended for a glucose/insulin ratio or IRT, and fasting a horse for 3 hours is recommended for the OST. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  15. Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  16. Estimating biodegradation half-lives for use in chemical screening.

    PubMed

    Aronson, Dallas; Boethling, Robert; Howard, Philip; Stiteler, William

    2006-06-01

    Biodegradation half-lives are needed for many applications in chemical screening, but these data are not available for most chemicals. To address this, in phase one of this work we correlated the much more abundant ready and inherent biodegradation test data with measured half-lives for water and soil. In phase two, we explored the utility of the BIOWIN models (in EPI Suite) and molecular fragments for predicting half-lives. BIOWIN model output was correlated directly with measured half-lives, and new models were developed by re-regressing the BIOWIN fragments against the half-lives. All of these approaches gave the best results when used for binary (fast/slow) classification of half-lives, with accuracy generally in the 70-80% range. In the last phase, we used the collected half-life data to examine the default half-lives assigned by EPI Suite and the PBT Profiler for use as input to their level III multimedia models. It is concluded that estimated half-lives should not be used for purposes other than binning or prioritizing chemicals unless accuracy improves significantly.

  17. Neutral desorption extractive electrospray ionization mass spectrometry for fast screening sunscreen agents in cream cosmetic products.

    PubMed

    Zhang, Xinglei; Liu, Yan; Zhang, Jinghua; Hu, Zhong; Hu, Bin; Ding, Liying; Jia, Li; Chen, Huanwen

    2011-09-15

    High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD=8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. SAMPL4 & DOCK3.7: lessons for automated docking procedures

    NASA Astrophysics Data System (ADS)

    Coleman, Ryan G.; Sterling, Teague; Weiss, Dahlia R.

    2014-03-01

    The SAMPL4 challenges were used to test current automated methods for solvation energy, virtual screening, pose and affinity prediction of the molecular docking pipeline DOCK 3.7. Additionally, first-order models of binding affinity were proposed as milestones for any method predicting binding affinity. Several important discoveries about the molecular docking software were made during the challenge: (1) Solvation energies of ligands were five-fold worse than any other method used in SAMPL4, including methods that were similarly fast, (2) HIV Integrase is a challenging target, but automated docking on the correct allosteric site performed well in terms of virtual screening and pose prediction (compared to other methods) but affinity prediction, as expected, was very poor, (3) Molecular docking grid sizes can be very important, serious errors were discovered with default settings that have been adjusted for all future work. Overall, lessons from SAMPL4 suggest many changes to molecular docking tools, not just DOCK 3.7, that could improve the state of the art. Future difficulties and projects will be discussed.

  19. A Computational Methodology to Screen Activities of Enzyme Variants

    PubMed Central

    Hediger, Martin R.; De Vico, Luca; Svendsen, Allan; Besenmatter, Werner; Jensen, Jan H.

    2012-01-01

    We present a fast computational method to efficiently screen enzyme activity. In the presented method, the effect of mutations on the barrier height of an enzyme-catalysed reaction can be computed within 24 hours on roughly 10 processors. The methodology is based on the PM6 and MOZYME methods as implemented in MOPAC2009, and is tested on the first step of the amide hydrolysis reaction catalyzed by the Candida Antarctica lipase B (CalB) enzyme. The barrier heights are estimated using adiabatic mapping and shown to give barrier heights to within 3 kcal/mol of B3LYP/6-31G(d)//RHF/3-21G results for a small model system. Relatively strict convergence criteria (0.5 kcal/(molÅ)), long NDDO cutoff distances within the MOZYME method (15 Å) and single point evaluations using conventional PM6 are needed for reliable results. The generation of mutant structures and subsequent setup of the semiempirical calculations are automated so that the effect on barrier heights can be estimated for hundreds of mutants in a matter of weeks using high performance computing. PMID:23284627

  20. Learning to exploit a hidden predictor in skill acquisition: Tight linkage to conscious awareness.

    PubMed

    Tran, Randy; Pashler, Harold

    2017-01-01

    It is often assumed that implicit learning of skills based on predictive relationships proceeds independently of awareness. To test this idea, four groups of subjects played a game in which a fast-moving "demon" made a brief appearance at the bottom of the computer screen, then disappeared behind a V-shaped occluder, and finally re-appeared briefly on either the upper-left or upper-right quadrant of the screen. Points were scored by clicking on the demon during the final reappearance phase. Demons differed in several visible characteristics including color, horn height and eye size. For some subjects, horn height perfectly predicted which side the demon would reappear on. For subjects not told the rule, the subset who demonstrated at the end of the experiment that they had spontaneously discovered the rule showed strong evidence of exploiting it by anticipating the demon's arrival and laying in wait for it. Those who could not verbalize the rule performed no better than a control group for whom the demons moved unpredictably. The implications of this tight linkage between conscious awareness and implicit skill learning are discussed.

  1. Occurrence of antimicrobial residues in Brazilian food animals in 2008 and 2009.

    PubMed

    Nonaka, C K V; Oliveira, A M G; Paiva, C R; Almeida, M P; Rezende, C P; Moraes, C G O; Botelho, B G; Souza, L F; Dias, P G

    2012-01-01

    Brazil is one of the most important countries as a producer and exporter of cattle and poultry. In 2009 cattle accounted for 30% of the export market and 41.4% for poultry meat. The Brazilian National Residues and Contaminants Control Plan (PNCRC) follows the guidelines set by the Codex Alimentarius Commission and checks compliance maximum residue limits (MRLs) to ensure the quality of these commodities. Kidney samples (n = 2978) were analysed between January 2008 and December 2009. Fifteen antibiotics of the macrolide and aminoglycoside groups (clindamycin, eritromycin, lincomycin, tylmicosin, tylosin, amikacin, apramycin, dihydrostreptomycin, gentamycin, higromycin, kanamycin, neomycin, spectinomycin, streptomycin, tobramycin) were determined by a microbiological screening method (FAST) and confirmed/quantified using liquid chromatography (LC-MS/MS and UPLC-MS/MS). In 2008, 1459 samples were analysed by a screening test and liquid chromatography with only one sample (0.07%) exceeded Brazilian legislation limits (>MRL). In 2009, 1519 samples were analysed and none exceeding Brazilian legislation limits (>MRL). The slaughterhouses of 16 states were monitored during the year of 2008, and 18 states were monitored in 2009, being the major producing states most sampled by the PNCRC.

  2. Diagnostic Performance of 48-Hour Fasting Test and Insulin Surrogates in Patients With Suspected Insulinoma.

    PubMed

    Ueda, Keijiro; Kawabe, Ken; Lee, Lingaku; Tachibana, Yuichi; Fujimori, Nao; Igarashi, Hisato; Oda, Yoshinao; Jensen, Robert T; Takayanagi, Ryoichi; Ito, Tetsuhide

    2017-04-01

    This study aimed to evaluate the usefulness of the 48-hour fasting test and insulin surrogates followed by a glucagon stimulatory test (GST) for the diagnosis of insulinoma. Thirty-five patients with suspected insulinoma who underwent 48-hour fasting test and GST were retrospectively included in our study: 15 patients with surgically proven insulinomas and 20 patients in whom insulinoma was clinically ruled out. We determined the duration of the fasting test, plasma glucose levels, serum levels of immunoreactive insulin and C-peptide, and insulin surrogates (serum levels of β-hydroxybutyrate, free fatty acid, and response of plasma glucose to intravenous glucagon [ΔPG]) at the end of the fast. The sensitivity and specificity of the 48-hour fasting test were 100.0% and 80.0%, respectively, for the diagnosis of insulinoma. When the 48-hour fasting test and immunoreactive insulin, C-peptide, or insulin surrogates were combined, the combination with GST showed the best results. The sensitivity, specificity, and accuracy rate were 93.3%, 95.0%, and 94.3%, respectively, with 1 false-negative case and 1 false-positive case occurring. A more accurate and less invasive diagnosis of insulinoma was possible by combining the 48-hour fasting test with the GST, compared with the existing method.

  3. [Spanish translation and validation of an Executive Battery 25 (EB25) and its shortened version (ABE12) for executive dysfunction screening in dementia].

    PubMed

    Serrani Azcurra, D J L

    2013-10-01

    There is a need for clinically administered instruments capable of detecting executive dysfunction in dementia. The translation and validation of Executive Battery 25 (EB25) and a short version for screening of executive dysfunction in dementia. The original battery was translated and validated using convergent and divergent correlation in 66 mild dementia patients (CDR 1) matched with 66 controls. EB25 consists of 25 items which detect executive dysfunction. Convergent correlation was made with 7 tests assessing executive dysfunction, the Frontal Systems Behaviour Scale (FrSBe) and Disability Fast Assessment Scale. Patients had higher scores than controls and correlated with the Stroop Test, verbal fluency test and Frontal Behaviour Inventory. Only 12 out of 25 items were needed to separate both groups, which were used to build an abbreviated Executive Battery with equal psychometric properties and discriminative power. The cut-off point for EB25 was 12, and 7 for the abbreviated version. A cut-off point of 12 was able to discriminate between ¿Alzheimer's disease? (AD) and frontotemporal lobe dementia (FTLD). EB25 and AEB12 enable executive dysfunction to be detected in mild dementia. On the other hand, AEB12 exhibits better psychometric properties than the original battery, allowing discrimination between AD and FTLD and is completed in less time. Copyright © 2010 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  4. Biochemical Profile of Nonalcoholic Fatty Liver Disease Patients in Eastern India with Histopathological Correlation.

    PubMed

    Swain, Manorama; Nath, Preetam; Parida, Prasant Kumar; Narayan, Jimmy; Padhi, Pradeep Kumar; Pati, Girish Kumar; Singh, Ayaskanta; Misra, Bijay; Misra, Debasis; Kar, Sanjib Kumar; Panigrahi, Manas Kumar; Meher, Chudamani; Agrawal, Omprakash; Rout, Niranjan; Pattnaik, Kaumudee; Bhuyan, Pallavi; Mishra, Pramila Kumari; Singh, Shivaram Prasad

    2017-07-01

    Aminotransferase assay is often used as a screening test as well as an endpoint for resolution of disease in nonalcoholic fatty liver disease (NAFLD). Aim of the study was to evaluate the relationship of transaminase level with metabolic variables and histology in NAFLD. Single center observational study was conducted in a gastroenterology clinic at Cuttack in coastal Odisha. Subjects were consecutive patients presenting with functional bowel disease and undergoing abdominal sonography. All participants were evaluated for the presence of metabolic syndrome (MS), insulin resistance, liver function test and lipid profile. Various parameters were compared between NAFLD subjects and controls. 53.5 % of NAFLD had normal serum transaminases, whereas 20.8 % of healthy controls had transaminitis. NAFLD patients had significantly higher BMI, fasting plasma glucose, serum transaminases, serum triglycerides, serum insulin and homeostatic model assessment (HOMA) IR than controls. NAFLD patients who had transaminitis had significantly higher incidence of MS and higher mean HOMA IR than those without. There was no significant difference in histopathological features between NAFLD with and without transaminitis. To conclude, over half of NAFLD subjects do not have transaminitis while transaminitis is present in a fifth of healthy people without fatty liver. Hence serum transaminase should not be used as screening test for NAFLD. NAFLD patients with transaminitis had a higher incidence of MS and insulin resistance than those without. However, there was no significant difference in histopathological features between these two groups.

  5. Next-generation sequencing-based method shows increased mutation detection sensitivity in an Indian retinoblastoma cohort

    PubMed Central

    Singh, Jaya; Mishra, Avshesh; Pandian, Arunachalam Jayamuruga; Mallipatna, Ashwin C.; Khetan, Vikas; Sripriya, S.; Kapoor, Suman; Agarwal, Smita; Sankaran, Satish; Katragadda, Shanmukh; Veeramachaneni, Vamsi; Hariharan, Ramesh; Subramanian, Kalyanasundaram

    2016-01-01

    Purpose Retinoblastoma (Rb) is the most common primary intraocular cancer of childhood and one of the major causes of blindness in children. India has the highest number of patients with Rb in the world. Mutations in the RB1 gene are the primary cause of Rb, and heterogeneous mutations are distributed throughout the entire length of the gene. Therefore, genetic testing requires screening of the entire gene, which by conventional sequencing is time consuming and expensive. Methods In this study, we screened the RB1 gene in the DNA isolated from blood or saliva samples of 50 unrelated patients with Rb using the TruSight Cancer panel. Next-generation sequencing (NGS) was done on the Illumina MiSeq platform. Genetic variations were identified using the Strand NGS software and interpreted using the StrandOmics platform. Results We were able to detect germline pathogenic mutations in 66% (33/50) of the cases, 12 of which were novel. We were able to detect all types of mutations, including missense, nonsense, splice site, indel, and structural variants. When we considered bilateral Rb cases only, the mutation detection rate increased to 100% (22/22). In unilateral Rb cases, the mutation detection rate was 30% (6/20). Conclusions Our study suggests that NGS-based approaches increase the sensitivity of mutation detection in the RB1 gene, making it fast and cost-effective compared to the conventional tests performed in a reflex-testing mode. PMID:27582626

  6. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  7. Screening for pre-diabetes to predict future diabetes using various cut-off points for HbA(1c) and impaired fasting glucose: the Toranomon Hospital Health Management Center Study 4 (TOPICS 4).

    PubMed

    Heianza, Y; Arase, Y; Fujihara, K; Tsuji, H; Saito, K; Hsieh, S D; Kodama, S; Shimano, H; Yamada, N; Hara, S; Sone, H

    2012-09-01

    To evaluate various screening criteria for pre-diabetes to identify which combination of impaired fasting glucose and elevated HbA(1c) values performs most effectively in predicting future diabetes in a large cohort of Japanese individuals. The study included 4670 men and 1571 women without diabetes (diabetes: fasting plasma glucose ≥ 7.0 mmol/l, HbA(1c) ≥ 48 mmol/mol (≥ 6.5%), or self-reported clinician-diagnosed diabetes). Pre-diabetes was diagnosed by a combination of impaired fasting glucose (fasting plasma glucose 5.6-6.9 mmol/l or 6.1-6.9 mmol/l) and elevated HbA(1c) [39-46 mmol/mol (5.7-6.4%) or 42-46 mmol/mol (6.0-6.4%)]. During a 5-year follow-up, 338 incident cases of diabetes occurred. The combination of HbA(1c) 39-46 mmol/mol (5.7-6.4%) and fasting plasma glucose 5.6-6.9 mmol/l yielded the highest sensitivity (86%) and generated a large population-attributable per cent risk (78%) for predicting development of diabetes. Among individuals classified as having pre-diabetes by any of the four combined criteria, 20.5-32.0% reverted to the normoglycaemic state as having neither elevated HbA(1c) nor impaired fasting glucose at the last follow-up examination. At 5.6 years after the baseline examination, however, pre-diabetic individuals who fulfilled both HbA(1c) 42-46 mmol/mol (6.0-6.4%) and fasting plasma glucose 6.1-6.9 mmol/l had a 100% cumulative risk of developing diabetes. The combination of HbA(1c) 39-46 mmol/mol (5.7-6.4%) and fasting plasma glucose 5.6-6.9 mmol/l would have the best performance in reducing the likelihood of missing future cases of diabetes. Identifying pre-diabetic individuals who strictly fulfil HbA(1c) 42-46 mmol/mol (6.0-6.4%) and fasting plasma glucose 6.1-6.9 mmol/l would predict definite progression to diabetes. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  8. Risks of Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  9. Clinical Variability in Cardiovascular Disease Risk Factor Screening and Management in Adolescent and Young Adult Women with Polycystic Ovary Syndrome.

    PubMed

    Baer, Tamara E; Milliren, Carly E; Walls, Courtney; DiVasta, Amy D

    2015-10-01

    To review the clinical presentation, evaluation, and management of normal-weight (NW), overweight (OW), and obese (OB) adolescent and young adult women with polycystic ovary syndrome (PCOS) during a 2-year follow-up. Retrospective chart review. One hundred seventy-three adolescent and young adult women, aged 12-22 years, diagnosed with PCOS. Demographic, health data, and laboratory measures were abstracted from 3 clinic visits: baseline and 1- and 2-year follow-up. Subjects were classified as NW, OW, or OB. Longitudinal data were analyzed using repeated-measures analysis of variance. Body mass index, self-reported concerns, and lifestyle changes. Most patients (73%) were OW or OB. Family history of type 2 diabetes was greater in OW (38%) and OB (53%) patients compared with NW (22%) patients (P = .002). Acanthosis nigricans was identified in OW (62%) and OB (21%) patients but not in NW patients (0%; P < .001). OW and OB patients had higher fasting insulin (P < .001) and lower high-density lipoprotein cholesterol (P = .005) levels than NW patients, although screening rates were low. Body mass index Z-scores decreased in both OW and OB patients over time (0.07 unit/yr, P < .001). Most patients with PCOS were OW or OB. Substantial clinical variability existed in cardiovascular disease (CVD) screening; among those screened, OW and OB patients had greater CVD risk factors. Despite self-reported concerns about weight and diabetes risk among OW and OB patients, no clinically significant change in body mass index percentile occurred. Evidence-based interventions and recommendations for screening tests are needed to address CVD risk in adolescents and young adults with PCOS. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  10. Accelerating evaluation of converged lattice thermal conductivity

    NASA Astrophysics Data System (ADS)

    Qin, Guangzhao; Hu, Ming

    2018-01-01

    High-throughput computational materials design is an emerging area in materials science, which is based on the fast evaluation of physical-related properties. The lattice thermal conductivity (κ) is a key property of materials for enormous implications. However, the high-throughput evaluation of κ remains a challenge due to the large resources costs and time-consuming procedures. In this paper, we propose a concise strategy to efficiently accelerate the evaluation process of obtaining accurate and converged κ. The strategy is in the framework of phonon Boltzmann transport equation (BTE) coupled with first-principles calculations. Based on the analysis of harmonic interatomic force constants (IFCs), the large enough cutoff radius (rcutoff), a critical parameter involved in calculating the anharmonic IFCs, can be directly determined to get satisfactory results. Moreover, we find a simple way to largely ( 10 times) accelerate the computations by fast reconstructing the anharmonic IFCs in the convergence test of κ with respect to the rcutof, which finally confirms the chosen rcutoff is appropriate. Two-dimensional graphene and phosphorene along with bulk SnSe are presented to validate our approach, and the long-debate divergence problem of thermal conductivity in low-dimensional systems is studied. The quantitative strategy proposed herein can be a good candidate for fast evaluating the reliable κ and thus provides useful tool for high-throughput materials screening and design with targeted thermal transport properties.

  11. Should glycated haemoglobin (HbA1c) be used to detect people with type 2 diabetes mellitus and impaired glucose regulation?

    PubMed

    Mostafa, Samiul A; Davies, Melanie J; Srinivasan, Balasubramanian Thiagarajan; Carey, Marian E; Webb, David; Khunti, Kamlesh

    2010-11-01

    There is a need to simplify screening tests for type 2 diabetes mellitus (T2DM) so patients can be identified earlier and more efficiently. Glycated haemoglobin (HbA1c) has been recommended by some international organisations as a diagnostic tool for detecting T2DM and impaired glucose regulation (IGR, also termed prediabetes and includes impaired fasting glucose and/or impaired glucose tolerance). The HbA1c cut-point of ≥6.5% (48 mmol/mol) has been selected as diagnostic for T2DM, while the cut-points for IGR are debated by the different international organisations: an International Expert Committee has suggested using HbA1c 6.0-6.4% (42-46 mmol/mol); however, the American Diabetes Association has recommended using HbA1c 5.7-6.4% (39-46 mmol/mol). Some countries will adopt a new method of reporting HbA1c values in millimoles per mole (mmol/mol). Use of HbA1c has some logistical advantages over using an oral glucose tolerance test (OGTT). As patients do not need to fast, appointments do not need to be limited to the morning. The HbA1c result reflects longer term glycaemia and is less affected by recent physical/emotional stress. However, there is some debate as to whether HbA1c should replace fasting plasma glucose or the OGTT. As the two tests detect different people, some individuals with diabetes detected on OGTT will no longer be classified as having T2DM using HbA1c ≥6.5% criteria. Furthermore, some medical conditions can result in HbA1c assay measurements not reflecting glycaemic control over the last 2-3 months; these include haematological disorders, renal failure, and chronic excess alcohol consumption.

  12. Fasting Triglycerides and Glucose Index as a Diagnostic Test for Insulin Resistance in Young Adults.

    PubMed

    Guerrero-Romero, Fernando; Villalobos-Molina, Rafael; Jiménez-Flores, J Rafael; Simental-Mendia, Luis E; Méndez-Cruz, René; Murguía-Romero, Miguel; Rodríguez-Morán, Martha

    2016-07-01

    Although the Glucose and Triglyceride levels (TyG) index is useful for identification of insulin resistance (IR) in different ethnic groups, it has not been evaluated in young adults. We undertook this study to evaluate the TyG index as a diagnostic test for IR in young adults. A total of 5,538 healthy young adults, 3,795 (68.5%) non-pregnant women and 1,743 (31.5%) men, with an average age of 19.2 ± 1.4 years, were enrolled in a population-based cross-sectional study. To estimate diagnostic characteristics of the TyG index, a randomized subsample of the target population (n = 75) was under euglycemic-hyperinsulinemic clamp test. Using the cutoff values obtained in the clamp study, the diagnostic concordance between TyG index and HOMA-IR was evaluated in the overall population. The TyG index was calculated as the Ln[fasting triglycerides (mg/dL) × fasting glucose (mg/dL)]/2. Normal weight, overweight, and obesity were identified in 3,632 (65.6%), 1,355 (24.5%), and 551 (9.9%) participants. A total of 346 (9.1%) men and 278 (15.9%) women exhibited IR. The best cutoff value of TyG index for diagnosis of IR was 4.55 (sensitivity 0.687, negative predictive value (NPV) 0.844, and negative likelihood ratio (NLR) 0.47) for women and 4.68 (sensitivity 0.673, NPV 0.900, and NLR 0.45) for men. In normal-weight individuals the diagnostic concordance between TyG index and HOMA-IR was 0.934 and 0.915, in the overweight subjects was 0.908 and 0.895 and, in the obese participants 0.916 and 0.950, for men and women, respectively. TyG index may be useful for screening IR in young adults. Copyright © 2016 IMSS. Published by Elsevier Inc. All rights reserved.

  13. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    PubMed

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Integral assessment of estrogenic potentials in sediment-associated samples: Part 2: Study of estrogen and anti-estrogen receptor-binding potentials of sediment-associated chemicals under different salinity conditions using the salinity-adapted enzyme-linked receptor assay.

    PubMed

    Kase, Robert; Hansen, Peter D; Fischer, Birgit; Manz, Werner; Heininger, Peter; Reifferscheid, Georg

    2009-01-01

    The enzyme-linked receptor assay (ELRA) detects estrogenic and anti-estrogenic effects at the molecular level of receptor binding and is a useful tool for the integrative assessment of ecotoxicological potentials caused by hormonally active agents (HAA) and endocrine disrupting compounds (EDC). The main advantage of the ELRA is its high sample throughput and its robustness against cytotoxicity and microbial contamination. After a methodological adaptation to salinity of the ELRA, according to the first part of this study, which increased its salinity tolerance and sensitivity for 17-beta-estradiol, the optimised ELRA was used to investigate 13 native sediments characterised by different levels of salinity and chemical contamination. The applicability of the ELRA for routine analysis in environmental assessment was evaluated. Salinity is often a critical factor for bioassays in ecotoxicological sediment assessment. Therefore, salinity of the samples was additionally adjusted to different levels to characterise its influence on elution and binding processes of receptor-binding substances. The ELRA was carried out with the human estrogen receptor alpha (ER) in a 96-well microplate format using the experimental setup known from the competitive immunoassay based on ligand-protein interaction. It is an important improvement that a physiologically relevant receptor was used as a linking protein instead of an antibody. The microplates were coated with a 17-beta-estradiol-BSA conjugate, and dilution series of estradiol and of native sediment samples were added and incubated with the ER. After a washing step, a biotinylated mouse anti-ER antibody was added to each well. Receptor binding to estradiol, agonistic and antagonistic receptor binding, were determined by a streptavidin-POD-biotin complex with subsequent measurement of the peroxidase activity at the wavelength of 450 nm using a commercial ELISA multiplate reader. The sediment elutriates and pore water samples of sediments were tested in a dilution series to evaluate at which dilution step the receptor-binding potential ends. In the elution process (see Section 2.1 to 2.2), a method was developed to adjust the salinity to the levels of the reference testings, which offers an appropriate option to adjust the salinity in both directions. Statistical evaluation was made with a combination of the Mann-Whitney U test and the pT-method. This part of the study characterised the environmental factor 'salinity' for prospective applications of the ELRA. Using reference substances such as 17-beta-estradiol, the ELRA showed sigmoid concentration-effect relations over a broad range from 0.05 mug/l to 100 mug/l under physiological conditions. After methodological optimisation, both sensitivity and tolerance of the assay against salinity could be significantly raised, and the ELRA became applicable under salinity conditions up to concentrations of 20.5 per thousand. The mean relative inter-test error (n = 3) was around 11% with reference substances and below 5% for single sediments elutriates in three replicates each. For sediment testings, the pore water and different salinity-adjusted elutriates of 13 sediments were used. A clear differentiation of the receptor-binding potential could be reached by application of the pT-method. Thereby, pT-values from one to six could be assigned to the sediments, and the deviation caused by the different salinity conditions was one pT-value. The mean standard deviation in the salinity adaptation procedure of the elutriates was below 5%. Although the ELRA has already been used for assessments of wastewater, sludge and soil, its applicability for samples to different salinity levels has not been investigated so far. Even if the ELRA is not as sensitive as the E-screen or the YES-assay, with regard to reference substances like 17-beta-estradiol, it is a very useful tool for pre-screening, because it is able to integrate both estrogenic as well as anti-estrogenic receptor-binding effects. According to the results of sediment testing, and given the integrative power to detect different directions of effects, the ELRA shows sufficient sensitivity and salinity tolerance to discriminate receptor-binding potentials in environmental samples. The optimised ELRA assay is a fast, cost-effective, reliable and highly reproducible tool that can be used for high-throughput screening in a microplate format in detecting both estrogenic and anti-estrogenic effects. Additionally, the ELRA is robust against microbial contaminations, and is not susceptible towards cytotoxic interferences like the common cell-culture methods. The general applicability and sufficient sensitivity of the ELRA was shown in freshwater environments. Marine and brackish samples can be measured up to salinity levels of 20.5 per thousand. In view of the proven sensitivity, functionality and the fastness of the ELRA, it is recommendable to standardise the test method. At the moment, no adequate in vitro test procedure exists which is standardised to DIN or ISO levels. The E-screen and the yeast estrogen/androgen screens (YES/YAS) sometimes underlie strong cytotoxic effects, as reported in the first part of this study. Further development of an ELRA assay using human androgen receptors appears to be very promising to gain information about androgenic and anti-androgenic effects, too. This would offer a possibility to use the ELRA as a fast and reliable pre-screening tool for the detection of endocrine potentials, thus minimising time and cost-expensive animal experiments.

  15. Dual-test monitoring of hyperglycemia using daily glucose and weekly fructosamine values.

    PubMed

    Carter, A W; Borchardt, N; Cooney, M; Greene, D

    2001-01-01

    The purpose of this study was to assess the impact of using a dual-test blood glucose/fructosamine home monitoring system to assist individuals identified as having the potential for poor glycemic control to achieve values closer to normal. Forty-eight subjects found to have a fasting blood glucose value of > or = 126 mg/dL, casual blood glucose value of > or = 140 mg/dL, and/or blood fructosamine value of > or = 310 micromol/L, agreed to perform daily self testing for 90 days and were provided a dual-test blood glucose/fructosamine home monitoring system and testing supplies at no charge to them. Medication changes/compliance along with dietary and exercise habits were compared to testing results by the principle investigator at approximate 30-day intervals. The desired goal of this project was to achieve and/or maintain a fasting blood glucose value of < or = 110 mg/dL, a casual blood glucose value of < or = 140 mg/dL and a blood fructosamine value of < or = 310 micromol/L by encouraging each individual to realize the effect of dietary intake and exercise habits, and understand the importance of medication compliance, if appropriate, in achieving better overall glycemic control. Four subjects withdrew from the study prior to completion, 11 of the remaining 44 completed 60 days of testing and 33 of 44 completed 90 days of testing. Regular monitoring and counseling achieved an average reduction in blood glucose of 27.5% and a 16.6% reduction in average blood fructosamine when compared to original screening results of these 44 individuals. This study indicates that the addition of weekly fructosamine values to daily blood glucose values provides both the patient and clinician valuable information to evaluate the impact of dietary, exercise, and medication therapy changes on glycemic control by bridging the existing gap between daily blood glucose values and quarterly HbA1c confirmation of intervention results.

  16. Pilot study to investigate the feasibility of the Home Falls and Accidents Screening Tool (HOME FAST) to identify older Malaysian people at risk of falls.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin

    2016-08-16

    The relationship between home hazards and falls in older Malaysian people is not yet fully understood. No tools to evaluate the Malaysian home environment currently exist. Therefore, this study aimed to pilot the Home Falls and Accidents Screening Tool (HOME FAST) to identify hazards in Malaysian homes, to evaluate the feasibility of using the HOME FAST in the Malaysian Elders Longitudinal Research (MELoR) study and to gather preliminary data about the experience of falls among a small sample of Malaysian older people. A cross-sectional pilot study was conducted. An urban setting in Kuala Lumpur. 26 older people aged 60 and over were recruited from the control group of a related research project in Malaysia, in addition to older people known to the researchers. The HOME FAST was applied with the baseline survey for the MELoR study via a face-to-face interview and observation of the home by research staff. The majority of the participants were female, of Malay or Chinese ethnicity and living with others in a double-storeyed house. Falls were reported in the previous year by 19% and 80% of falls occurred at home. Gender and fear of falling had the strongest associations with home hazards. Most hazards were detected in the bathroom area. A small number of errors were detected in the HOME FAST ratings by researchers. The HOME FAST is feasible as a research and clinical tool for the Malaysian context and is appropriate for use in the MELoR study. Home hazards were prevalent in the homes of older people and further research with the larger MELoR sample is needed to confirm the validity of using the HOME FAST in Malaysia. Training in the use of the HOME FAST is needed to ensure accurate use by researchers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. A Population-based Screening of Type 2 Diabetes in High-risk Population of Yasuj, Iran

    PubMed Central

    Yazdanpanah, Behrouz; Yazdanpanah, Behzad; Mobasheri, Ali

    2014-01-01

    ABSTRACT Complications associated with diabetes can be prevented by early diagnostics. A high-risk population was screened for diabetes, and the prevalence of undiagnosed diabetes mellitus (DM) and impaired fasting glucose (IFG) were used for examining the impacts of lifestyle, social and anthropometric features, and other risk factors. The target population comprised 30-65 years old residents from the western suburbs of Yasuj. Homes were approached, and a standard questionnaire was used for collecting information on sex, blood pressure, weight, height, and BMI for each participant. The high-risk participants were recognized according to the National Diabetes Prevention and Control Committee criteria and were introduced to an assigned laboratory. Blood samples were collected after 12-hour fasting for the measurement of total cholesterol, triglycerides and fasting glucose levels. The statistical analysis was performed with the SPSS statistical package, using a logistic regression model. Out of 2,569 individuals, 1,336 (52%) were with high-risk diabetes, 71.5% were female, and 28.5% were male. Of 191 (7.4%) individuals with known diabetes, 5 (2.6%) had type 1 diabetes; 881 (66.9%) out of 1,336 high-risk individuals were referred to assigned laboratory. Of 881 high-risk individuals, 157 (17.8%) had fasting blood sugar (FBS) ≥126 mg/dL and 118 (13.4%) had FBS between110 and 125 mg/dL. Percentages of participants with triglyceride ≥150 mg/dL and cholesterol ≥200 mg/dL were 298 (33.8%) and 207 (23.5%) respectively. Diabetes was associated with ageing, dyslipidaemia, family history of diabetes, lower physical activity on occupation, intake of lower dietary fibre, and non-literacy in the sampled population. This study suggests that diabetes is a common health problem in this area. Furthermore, considerable rate of newly-diagnosed diabetes signifies the importance of the screening programme. PMID:25895201

  18. Cancer Screening: How Do Screening Tests Become Standard Tests?

    MedlinePlus

    ... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...

  19. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  20. Depression, anxiety, and prevalent diabetes in the Chinese population: Findings from the China Kadoorie Biobank of 0.5 million people

    PubMed Central

    Mezuk, Briana; Chen, Yiping; Yu, Canqing; Guo, Yu; Bian, Zheng; Collins, Rory; Chen, Junshi; Pang, Zengchang; Wang, Huijun; Peto, Richard; Que, Xiangsan; Zhang, Hui; Tan, Zhongwen; Kendler, Kenneth S.; Li, Liming; Chen, Zhengming

    2013-01-01

    Objective Despite previous investigation, uncertainty remains about the nature of the associations of major depression (MD) with type 2 diabetes mellitus (T2DM), particularly in adult Chinese, and the relevance of generalized anxiety disorder (GAD) for T2DM. Methods Cross-sectional data from the China Kadoorie Biobank Study, a sample of approximately 500,000 adults from 10 geographically defined regions of China, were analyzed. Past year MD and GAD were assessed using the Composite International Diagnostic Inventory. T2DM was defined as either having self-reported physician diagnosis of diabetes at age 30 or later (“clinically-identified” cases) or having a non-fasting blood glucose ≥11.1 mmol/L or fasting blood glucose ≥7.0 mmol/L but no prior diagnosis of diabetes (“screen-detected” cases). Logistic regression was used to assess the relationship between MD and GAD with clinically-identified and screen-detected T2DM, adjusting for demographic characteristics and health behaviors. Results The prevalence of T2DM was 5.3% (3.2% clinically-identified and 2.1% screen-detected). MD was significantly associated with clinically-identified T2DM (Odds ratio [OR]: 1.75, 95% Confidence Interval (CI): 1.47 – 2.08), but not with screen-detected T2DM (OR: 1.18, 95% CI: 0.92 – 1.51). GAD was associated with both clinically-identified (OR: 2.14, 95% CI: 1.60 – 2.88) and screen-detected (OR: 1.44, 95% CI: 0.99 – 2.08) T2DM. The relationship between MD and GAD with T2DM was moderated by obesity. Conclusion MD is associated with clinically-identified, but not screen-detected T2DM. GAD is associated with both clinically-identified and screen-detected T2DM. The relationship between MD and T2DM is strongest among those who are not obese. PMID:24290039

  1. Blunt abdominal trauma in children.

    PubMed

    Schonfeld, Deborah; Lee, Lois K

    2012-06-01

    This review will examine the current evidence regarding pediatric blunt abdominal trauma and the physical exam findings, laboratory values, and radiographic imaging associated with the diagnosis of intra-abdominal injuries (IAI), as well as review the current literature on pediatric hollow viscus injuries and emergency department disposition after diagnosis. The importance of the seat belt sign on physical examination and screening laboratory data remains controversial, although screening hepatic enzymes are recommended in the evaluation of nonaccidental trauma to identify occult abdominal organ injuries. Focused Assessment with Sonography for Trauma (FAST) has modest sensitivity for hemoperitoneum and IAI in the pediatric trauma patient. Patients with concern for undiagnosed IAI, including bowel injury, may be considered for hospital admission and serial abdominal exams without an increased risk of complications, if an exploratory laparotomy is not performed emergently. Although the FAST exam is not recommended as the sole screening tool to rule out IAI in hemodynamically stable trauma patients, it may be used in conjunction with the physical exam and laboratory findings to identify children at risk for IAI. Children with a normal physical exam and normal abdominal CT may not require routine hospitalization after blunt abdominal trauma.

  2. An Automated Method for High-Throughput Screening of Arabidopsis Rosette Growth in Multi-Well Plates and Its Validation in Stress Conditions.

    PubMed

    De Diego, Nuria; Fürst, Tomáš; Humplík, Jan F; Ugena, Lydia; Podlešáková, Kateřina; Spíchal, Lukáš

    2017-01-01

    High-throughput plant phenotyping platforms provide new possibilities for automated, fast scoring of several plant growth and development traits, followed over time using non-invasive sensors. Using Arabidops is as a model offers important advantages for high-throughput screening with the opportunity to extrapolate the results obtained to other crops of commercial interest. In this study we describe the development of a highly reproducible high-throughput Arabidopsis in vitro bioassay established using our OloPhen platform, suitable for analysis of rosette growth in multi-well plates. This method was successfully validated on example of multivariate analysis of Arabidopsis rosette growth in different salt concentrations and the interaction with varying nutritional composition of the growth medium. Several traits such as changes in the rosette area, relative growth rate, survival rate and homogeneity of the population are scored using fully automated RGB imaging and subsequent image analysis. The assay can be used for fast screening of the biological activity of chemical libraries, phenotypes of transgenic or recombinant inbred lines, or to search for potential quantitative trait loci. It is especially valuable for selecting genotypes or growth conditions that improve plant stress tolerance.

  3. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  4. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  5. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  6. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  7. Anthropometric indices are not satisfactory predictors of metabolic comorbidities in obese children and adolescents.

    PubMed

    Morandi, Anita; Miraglia Del Giudice, Emanuele; Martino, Francesco; Martino, Eliana; Bozzola, Mauro; Maffeis, Claudio

    2014-12-01

    To assess the accuracy of body mass index (BMI), Z score of the BMI, waist circumference, and waist-to-height ratio in selecting obese children with fasting metabolic impairments or impaired glucose tolerance. In a cohort of 883 obese children and adolescents (age 8-18 years), we assessed the associations of anthropometric indices with traditional metabolic complications of obesity (impaired fasting glucose, impaired glucose tolerance, hypertension, high triglycerides, low high-density lipoprotein-cholesterol). The accuracy of anthropometric indices as markers of metabolic impairment was assessed by receiver operating characteristic analysis and the areas under the receiver operating characteristics curves (AUROCs) of anthropometric indices were compared with each other by the DeLong test. BMI, Z score of the BMI, waist circumference, and waist-to-height ratio were associated with metabolic impairments but showed low to moderate accuracy in discriminating both single and clustered metabolic impairments. The AUROCs ranged from 0.55-0.70. The 4 anthropometric indices did not show significantly different AUROCs as predictors of clustered metabolic risk factors (all P values of DeLong tests: >.05). Commonly used anthropometric indices are not satisfactory markers of metabolic comorbidity among obese children and adolescents and should not be adopted as screening tools for the metabolic assessment of this category of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Adherence to multiple cancer screening tests among women living in Appalachia Ohio

    PubMed Central

    Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.

    2015-01-01

    Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630

  9. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  10. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  11. Special Section: Preventing, Detecting, and Treating Colorectal Cancer

    MedlinePlus

    ... long series to promote colon and rectal (colorectal) cancer awareness and screening. Following that, research showed that the ... has helped to raise millions of dollars for cancer research and awareness programs. Fast Facts Cancers of the colon and ...

  12. Testing and screening for chlamydia in general practice: a cross-sectional analysis.

    PubMed

    Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker

    2014-12-01

    Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.

  13. The effect of presenting information about invasive follow-up testing on individuals' noninvasive colorectal cancer screening participation decision: results from a discrete choice experiment.

    PubMed

    Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D

    2014-07-01

    Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  14. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  15. Computerized classification of auditory trauma: Results of an investigation on screening employees exposed to noise

    NASA Technical Reports Server (NTRS)

    Klockhoff, I.

    1977-01-01

    An automatic, computerized method was developed to classify results from a screening of employees exposed to noise, resulting in a fast and effective method of identifying and taking measures against auditory trauma. This technique also satisfies the urgent need for quick discovery of cases which deserve compensation in accordance with the Law on Industrial Accident Insurance. Unfortunately, use of this method increases the burden on the already overloaded investigatory resources of the auditory health care system.

  16. Giving them a good start: informatics support of newborn screening and clinical care.

    PubMed

    Wetter, T; Haschler, I; Ho, S; Hoffmann, G F; Linderkamp, O; Philipp, F; Skonetzki, S

    2005-01-01

    Newborns are a vulnerable population: Exposed to dramatically changing environmental conditions, potentially suffering from impairments that cannot realistically be diagnosed during pregnancy, with the risk that unfavorable conditions escalate fast. We have investigated informatics methods and tools to make screening for congenital diseases and containment of critical processes that start in the first days safer and more efficient. This poster present a set of three different methodological approaches that all aim at comprehensive improvement of neonatal care.

  17. Screening and identification of Lipase Producing Bacterium

    NASA Astrophysics Data System (ADS)

    Zheng, Chaocheng

    2018-01-01

    55 samples from different regions were selected and screened by Rhodamine B flat transparent circle method to observe lipase producing effect, among which, LHY-1, identified as Serratia sp. has the characteristics of fast growth, high enzyme production and stable ability. The colony of this strain is white, the edge is smooth and tidy, the surface is moist, the cell is straight, rod-shaped, gram negative, 0.1-0.2 μm in diameter and, length 0.3-0.5 μm in length.

  18. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  19. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  20. Missed opportunities in primary care: the importance of identifying depression through screening, family history, and chronic disease management.

    PubMed

    Maradiegue, Ann H; Khan, Fakiha

    2013-02-01

    This study explored the adequacy of depression screening in a community health center. The medical charts of individuals (N = 90) enrolled at a community health center were randomly selected, reviewed, and compared to current standard-of-care guidelines for four elements: family history, screening for depression, control of chronic illnesses, and missed opportunities for preventive care. Family history documentation collected by the providers was limited and 44.4% had no family history. There was no routine depression screening process, although 48.9% of the clients had red flags (warning signals) for depression. Laboratory values used for screening control of chronic disease in the medical records were: fasting glucose levels ⩽100 mg/dL (46%), total cholesterol levels ⩽200 mg/dL (38%), and blood pressure ⩽120/80 mmHg (23%). The results highlight the need to focus on depression screening as part of preventive care and the management of chronic disease in the primary care setting. Copyright 2013, SLACK Incorporated.

  1. [Screening for malnutrition among hospitalized patients in a Colombian University Hospital].

    PubMed

    Cruz, Viviana; Bernal, Laura; Buitrago, Giancarlo; Ruiz, Álvaro J

    2017-04-01

    On admission, 30 to 50% of hospitalized patients have some degree of malnutrition, which is associated with longer length of stay, higher rates of complications, mortality and greater costs. To determine the frequency of screening for risk of malnutrition in medical records and assess the usefulness of the Malnutrition Screening Tool (MST). In a cross-sectional study, we searched for malnutrition screening in medical records, and we applied the MST tool to hospitalized patients at the Internal Medicine Wards of San Ignacio University Hospital. Of 295 patients included, none had been screened for malnutrition since hospital admission. Sixty one percent were at nutritional risk, with a higher prevalence among patients with HIV (85.7%), cancer (77.5%) and pneumonia. A positive MST result was associated with a 3.2 days increase in length of hospital stay (p = 0.024). The prevalence of malnutrition risk in hospitalized patients is high, but its screening is inadequate and it is underdiagnosed. The MST tool is simple, fast, low-cost, and has a good diagnostic performance.

  2. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  3. Mutation screening for thalassaemia in the Jino ethnic minority population of Yunnan Province, Southwest China.

    PubMed

    Wang, Shiyun; Zhang, Rong; Xiang, Guangxin; Li, Yang; Hou, Xuhong; Jiang, Fusong; Jiang, Feng; Hu, Cheng; Jia, Weiping

    2015-12-29

    This study aimed to detect α- and β-thalassaemia mutations in the Jino ethnic minority population of Yunnan Province, Southwest China. A total of 1613 Jino adults were continuously recruited from February 2012 to April 2012. Fasting venous blood samples were obtained to determine haematological variables. Haemoglobin analysis was conducted using high-performance liquid chromatography. Participants with hypochromic microcytic anaemia or positive haemoglobin analysis profiles were confirmed by α- and β-globin genetic testing, including DNA microarray analysis, direct sequencing methods and multiplex gap-PCR assays. Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Jiao Tong University Affiliated Sixth People's Hospital. We found 363 suspected cases by primary screening of haematological variables and haemoglobin analysis. After further genetic testing, four types of α- and β-thalassaemia mutation were detected in 203 out of 363 individuals. Both α(0)- and α(+)-thalassaemia mutations, --(SEA) and -α(3.7), were identified. β-Thalassaemia mutations included CD17 (HBB:c.52A>T) and CD26 (HbE or HBB:c.79G>A). In addition, 13 HbE carriers had coexisting α(0)- or α(+)-thalassaemia deletions. Clinical haematological variables indicated that, in this study, carriers of all thalassaemic genotypes had more severe hypochromic microcytic anaemia than non-thalassaemic individuals. Our results provide information on the Jino ethnic minority that may be useful for further genetic counselling, prenatal screening and clinical diagnosis of thalassaemia in this region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Screening for phaeochromocytoma and paraganglioma: impact of using supine reference intervals for plasma metanephrines with samples collected from fasted/seated patients.

    PubMed

    Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M

    2017-01-01

    Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.

  5. LIGSIFT: an open-source tool for ligand structural alignment and virtual screening.

    PubMed

    Roy, Ambrish; Skolnick, Jeffrey

    2015-02-15

    Shape-based alignment of small molecules is a widely used approach in computer-aided drug discovery. Most shape-based ligand structure alignment applications, both commercial and freely available ones, use the Tanimoto coefficient or similar functions for evaluating molecular similarity. Major drawbacks of using such functions are the size dependence of the score and the fact that the statistical significance of the molecular match using such metrics is not reported. We describe a new open-source ligand structure alignment and virtual screening (VS) algorithm, LIGSIFT, that uses Gaussian molecular shape overlay for fast small molecule alignment and a size-independent scoring function for efficient VS based on the statistical significance of the score. LIGSIFT was tested against the compounds for 40 protein targets available in the Directory of Useful Decoys and the performance was evaluated using the area under the ROC curve (AUC), the Enrichment Factor (EF) and Hit Rate (HR). LIGSIFT-based VS shows an average AUC of 0.79, average EF values of 20.8 and a HR of 59% in the top 1% of the screened library. LIGSIFT software, including the source code, is freely available to academic users at http://cssb.biology.gatech.edu/LIGSIFT. Supplementary data are available at Bioinformatics online. skolnick@gatech.edu. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. High-Resolution Melt Analysis for Rapid Comparison of Bacterial Community Compositions

    PubMed Central

    Hjelmsø, Mathis Hjort; Hansen, Lars Hestbjerg; Bælum, Jacob; Feld, Louise; Holben, William E.

    2014-01-01

    In the study of bacterial community composition, 16S rRNA gene amplicon sequencing is today among the preferred methods of analysis. The cost of nucleotide sequence analysis, including requisite computational and bioinformatic steps, however, takes up a large part of many research budgets. High-resolution melt (HRM) analysis is the study of the melt behavior of specific PCR products. Here we describe a novel high-throughput approach in which we used HRM analysis targeting the 16S rRNA gene to rapidly screen multiple complex samples for differences in bacterial community composition. We hypothesized that HRM analysis of amplified 16S rRNA genes from a soil ecosystem could be used as a screening tool to identify changes in bacterial community structure. This hypothesis was tested using a soil microcosm setup exposed to a total of six treatments representing different combinations of pesticide and fertilization treatments. The HRM analysis identified a shift in the bacterial community composition in two of the treatments, both including the soil fumigant Basamid GR. These results were confirmed with both denaturing gradient gel electrophoresis (DGGE) analysis and 454-based 16S rRNA gene amplicon sequencing. HRM analysis was shown to be a fast, high-throughput technique that can serve as an effective alternative to gel-based screening methods to monitor microbial community composition. PMID:24610853

  7. Stanford GEMS phase 2 obesity prevention trial for low-income African-American girls: design and sample baseline characteristics.

    PubMed

    Robinson, Thomas N; Kraemer, Helena C; Matheson, Donna M; Obarzanek, Eva; Wilson, Darrell M; Haskell, William L; Pruitt, Leslie A; Thompson, Nikko S; Haydel, K Farish; Fujimoto, Michelle; Varady, Ann; McCarthy, Sally; Watanabe, Connie; Killen, Joel D

    2008-01-01

    African-American girls and women are at high risk of obesity and its associated morbidities. Few studies have tested obesity prevention strategies specifically designed for African-American girls. This report describes the design and baseline findings of the Stanford GEMS (Girls health Enrichment Multi-site Studies) trial to test the effect of a two-year community- and family-based intervention to reduce weight gain in low-income, pre-adolescent African-American girls. Randomized controlled trial with measurements scheduled in girls' homes at baseline, 6, 12, 18 and 24 month post-randomization. Low-income areas of Oakland, CA. Eight, nine and ten year old African-American girls and their parents/caregivers. Girls are randomized to a culturally-tailored after-school dance program and a home/family-based intervention to reduce screen media use versus an information-based community health education Active-Placebo Comparison intervention. Interventions last for 2 years for each participant. Change in body mass index over the two-year study. Recruitment and enrollment successfully produced a predominately low-socioeconomic status sample. Two-hundred sixty one (261) families were randomized. One girl per family is randomly chosen for the analysis sample. Randomization produced comparable experimental groups with only a few statistically significant differences. The sample had a mean body mass index (BMI) at the 74 th percentile on the 2000 CDC BMI reference, and one-third of the analysis sample had a BMI at the 95th percentile or above. Average fasting total cholesterol and LDL cholesterol were above NCEP thresholds for borderline high classifications. Girls averaged low levels of moderate to vigorous physical activity, more than 3 h per day of screen media use, and diets high in energy from fat. The Stanford GEMS trial is testing the benefits of culturally-tailored after-school dance and screen-time reduction interventions for obesity prevention in low-income, pre-adolescent African-American girls.

  8. Alternative indices of glucose homeostasis as biochemical diagnostic tests for abnormal glucose tolerance in an African setting.

    PubMed

    Kengne, Andre Pascal; Erasmus, Rajiv T; Levitt, Naomi S; Matsha, Tandi E

    2017-04-01

    Accurate diabetes diagnosis is important in Africa, where rates are increasing, and the disease largely undiagnosed. The cumbersome oral glucose tolerance test (OGTT) remains the reference standard, while alternative diagnostic methods are not yet established in Africans. We assessed the ability of fasting plasma glucose (FPG), HbA1c and fructosamine, to diagnose OGTT-based abnormal glucose tolerance in mixed-ancestry South Africans. Mixed-ancestry adults, residing in Cape Town were examined between February and November 2015. OGTT values were used to classify glucose tolerance status as: screen-detected diabetes, prediabetes, dysglycaemia (combination of diabetes and prediabetes) and normal glucose tolerance. Of the 793 participants included, 65 (8.2%) had screen-detected diabetes, 157 (19.8%) prediabetes and 571 (72.0%) normal glucose tolerance. Correlations of FPG and 2-h glucose with HbA1c (r=0.51 and 0.52) were higher than those with fructosamine (0.34 and 0.30), both p<0.0001. The highest c-statistic for the prediction of abnormal glucose tolerance was recorded with 2-h glucose [c-statistic=0.997 (screen-detected diabetes), 0.979 (prediabetes) and 0.984 (dysglycaemia)] and the lowest with fructosamine (0.865, 0.596 and 0.677). At recommended or data-specific optimal cut-offs, no combination of FPG, HbA1c and fructosamine did better than 2-h glucose, while FPG was better than HbA1c and fructosamine on a range of performance measures. Abnormal glucose tolerance in this population is overwhelmingly expressed through 2-h glucose's abnormalities; and no combination of FPG, HbA1c and fructosamine was effective at accurately discriminating OGTT-defined abnormal glucose tolerance. Tested non-glucose based strategies are unreliable alternatives to OGTT for dysglycaemia diagnosis in this population. Copyright © 2017 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  9. Novel method for quantitative ANA measurement using near-infrared imaging.

    PubMed

    Peterson, Lisa K; Wells, Daniel; Shaw, Laura; Velez, Maria-Gabriela; Harbeck, Ronald; Dragone, Leonard L

    2009-09-30

    Antinuclear antibodies (ANA) have been detected in patients with systemic rheumatic diseases and are used in the screening and/or diagnosis of autoimmunity in patients as well as mouse models of systemic autoimmunity. Indirect immunofluorescence (IIF) on HEp-2 cells is the gold standard for ANA screening. However, its usefulness is limited in diagnosis, prognosis and monitoring of disease activity due to the lack of standardization in performing the technique, subjectivity in interpreting the results and the fact that it is only semi-quantitative. Various immunological techniques have been developed in an attempt to improve upon the method to quantify ANA, including enzyme-linked immunosorbent assays (ELISAs), line immunoassays (LIAs), multiplexed bead immunoassays and IIF on substrates other than HEp-2 cells. Yet IIF on HEp-2 cells remains the most common screening method for ANA. In this study, we describe a simple quantitative method to detect ANA which combines IIF on HEp-2 coated slides with analysis using a near-infrared imaging (NII) system. Using NII to determine ANA titer, 86.5% (32 of 37) of the titers for human patient samples were within 2 dilutions of those determined by IIF, which is the acceptable range for proficiency testing. Combining an initial screening for nuclear staining using microscopy with titration by NII resulted in 97.3% (36 of 37) of the titers detected to be within two dilutions of those determined by IIF. The NII method for quantitative ANA measurements using serum from both patients and mice with autoimmunity provides a fast, relatively simple, objective, sensitive and reproducible assay, which could easily be standardized for comparison between laboratories.

  10. Biosensor discovery of thyroxine transport disrupting chemicals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marchesini, Gerardo R.; Meimaridou, Anastasia; Haasnoot, Willem

    2008-10-01

    Ubiquitous chemicals may interfere with the thyroid system that is essential in the development and physiology of vertebrates. We applied a surface plasmon resonance (SPR) biosensor-based screening method for the fast screening of chemicals with thyroxine (T4) transport disrupting activity. Two inhibition assays using the main thyroid hormone transport proteins, T4 binding globulin (TBG) and transthyretin (TTR), in combination with a T4-coated biosensor chip were optimized and automated for screening chemical libraries. The transport protein-based biosensor assays were rapid, high throughput and bioeffect-related. A library of 62 chemicals including the natural hormones, polychlorinated biphenyls (PCBs), polybrominated diphenylethers (PBDEs) and metabolites,more » halogenated bisphenol A (BPA), halogenated phenols, pharmaceuticals, pesticides and other potential environmentally relevant chemicals was tested with the two assays. We discovered ten new active compounds with moderate to high affinity for TBG with the TBG assay. Strikingly, the most potent binding was observed with hydroxylated metabolites of the brominated diphenyl ethers (BDEs) BDE 47, BDE 49 and BDE 99, that are commonly found in human plasma. The TTR assay confirmed the activity of previously identified hydroxylated metabolites of PCBs and PBDEs, halogenated BPA and genistein. These results show that the hydroxylated metabolites of the ubiquitous PBDEs not only target the T4 transport at the TTR level, but also, and to a great extent, at the TBG level where most of the T4 in humans is circulating. The optimized SPR biosensor-based transport protein assay is a suitable method for high throughput screening of large libraries for potential thyroid hormone disrupting compounds.« less

  11. Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient.

    PubMed

    Caballero, D; Kaushik, S; Correlo, V M; Oliveira, J M; Reis, R L; Kundu, S C

    2017-12-01

    Most cancer patients do not die from the primary tumor but from its metastasis. Current in vitro and in vivo cancer models are incapable of satisfactorily predicting the outcome of various clinical treatments on patients. This is seen as a serious limitation and efforts are underway to develop a new generation of highly predictive cancer models with advanced capabilities. In this regard, organ-on-chip models of cancer metastasis emerge as powerful predictors of disease progression. They offer physiological-like conditions where the (hypothesized) mechanistic determinants of the disease can be assessed with ease. Combined with high-throughput characteristics, the employment of organ-on-chip technology would allow pharmaceutical companies and clinicians to test new therapeutic compounds and therapies. This will permit the screening of a large battery of new drugs in a fast and economic manner, to accelerate the diagnosis of the disease in the near future, and to test personalized treatments using cells from patients. In this review, we describe the latest advances in the field of organ-on-chip models of cancer metastasis and their integration with advanced imaging, screening and biosensing technologies for future precision medicine applications. We focus on their clinical applicability and market opportunities to drive us forward to the next generation of tumor models for improved cancer patient theranostics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. A rapid nuclear staining test using cationic dyes contributes to efficient STR analysis of telogen hair roots.

    PubMed

    Lee, So-Yeon; Ha, Eun-Ju; Woo, Seung-Kyun; Lee, So-Min; Lim, Kyung-Hee; Eom, Yong-Bin

    2017-07-01

    Telogen hairs presented in the crime scene are commonly encountered as trace evidence. However, short tandem repeat (STR) profiling of the hairs currently have low and limited use due to poor success rate. To increase the success rate of STR profiling of telogen hairs, we developed a rapid and cost-effective method to estimate the number of nuclei in the hair roots. Five cationic dyes, Methyl green (MG), Harris hematoxylin (HH), Methylene blue (MB), Toluidine blue (TB), and Safranin O (SO) were evaluated in this study. We conducted a screening test based on microscopy and the percentage of loss with nuclear DNA, in order to select the best dye. MG was selected based on its specific nuclei staining and low adverse effect on the hair-associated nuclear DNA. We examined 330 scalp and 100 pubic telogen hairs with MG. Stained hairs were classified into five groups and analyzed by STR. The fast staining method revealed 70% (head hair) and 33.4% (pubic hair) of full (30 alleles) and high partial (18-29 alleles) STR profiling proportion from the lowest nuclei count group (one to ten nuclei). The results of this study demonstrated a rapid, specific, nondestructive, and high yield DNA profiling method applicable for screening telogen hairs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Screening and brief interventions for hazardous and harmful alcohol use in primary care: a cluster randomised controlled trial protocol

    PubMed Central

    Kaner, Eileen; Bland, Martin; Cassidy, Paul; Coulton, Simon; Deluca, Paolo; Drummond, Colin; Gilvarry, Eilish; Godfrey, Christine; Heather, Nick; Myles, Judy; Newbury-Birch, Dorothy; Oyefeso, Adenekan; Parrott, Steve; Perryman, Katherine; Phillips, Tom; Shenker, Don; Shepherd, Jonathan

    2009-01-01

    Background There have been many randomized controlled trials of screening and brief alcohol intervention in primary care. Most trials have reported positive effects of brief intervention, in terms of reduced alcohol consumption in excessive drinkers. Despite this considerable evidence-base, key questions remain unanswered including: the applicability of the evidence to routine practice; the most efficient strategy for screening patients; and the required intensity of brief intervention in primary care. This pragmatic factorial trial, with cluster randomization of practices, will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in primary care and different intensities of brief intervention to reduce excessive drinking in primary care patients. Methods and design GPs and nurses from 24 practices across the North East (n = 12), London and South East (n = 12) of England will be recruited. Practices will be randomly allocated to one of three intervention conditions: a leaflet-only control group (n = 8); brief structured advice (n = 8); and brief lifestyle counselling (n = 8). To test the relative effectiveness of different screening methods all practices will also be randomised to either a universal or targeted screening approach and to use either a modified single item (M-SASQ) or FAST screening tool. Screening randomisation will incorporate stratification by geographical area and intervention condition. During the intervention stage of the trial, practices in each of the three arms will recruit at least 31 hazardous or harmful drinkers who will receive a short baseline assessment followed by brief intervention. Thus there will be a minimum of 744 patients recruited into the trial. Discussion The trial will evaluate the impact of screening and brief alcohol intervention in routine practice; thus its findings will be highly relevant to clinicians working in primary care in the UK. There will be an intention to treat analysis of study outcomes at 6 and 12 months after intervention. Analyses will include patient measures (screening result, weekly alcohol consumption, alcohol-related problems, public service use and quality of life) and implementation measures from practice staff (the acceptability and feasibility of different models of brief intervention.) We will also examine organisational factors associated with successful implementation. Trial registration Current Controlled Trials ISRCTN06145674. PMID:19664255

  14. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  15. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  16. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  17. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  18. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  19. Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.

    PubMed

    Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L

    2010-06-01

    To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.

  20. Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.

    PubMed

    Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L

    2017-05-01

    To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  1. Neuroblastoma Screening

    MedlinePlus

    ... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  2. Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening

    PubMed Central

    Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.

    2017-01-01

    Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037

  3. Potential Biases Introduced by Conflating Screening and Diagnostic Testing in Colorectal Cancer Screening Surveillance

    PubMed Central

    Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.

    2015-01-01

    Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056

  4. Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  5. Glucose screening tests during pregnancy

    MedlinePlus

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... first step, you will have a glucose screening test: You DO NOT need to prepare or change ...

  6. Clues for minimal hepatic encephalopathy in children with noncirrhotic portal hypertension.

    PubMed

    D'Antiga, Lorenzo; Dacchille, Patrizia; Boniver, Clementina; Poledri, Sara; Schiff, Sami; Zancan, Lucia; Amodio, Piero

    2014-12-01

    In children with noncirrhotic extrahepatic portal vein obstruction (EHPVO), minimal hepatic encephalopathy (MHE) was reported in a few series, but neither is it routinely investigated nor does consensus about its diagnosis exist. In this prospective observational study we aimed at detecting the prevalence of MHE in children with EHPVO and providing a practical diagnostic protocol. A consecutive sample of 13 noncirrhotic children (age range 4-18 years) with EHPVO underwent a screening for MHE based on level of fasting ammonia, quantified electroencephalogram (EEG) evaluation, and a wide battery of 26 psychometric tests exploring learning ability, abstract reasoning, phonemic and semantic fluency, selective attention, executive functions, short-term verbal and visual memory, long-term verbal memory, and visuopractic ability. Five children had at least 2 altered psychometric tests. Selective attention, executive function, and short-term visual memory were the domains more frequently altered, and 4 tests were enough to detect 80% of these children. Fasting ammonia plasma level was increased in 6 children. EEG mean dominant frequency adjusted for age was associated with serum ammonia concentration (β = -0.44 ± 0.19, P < 0.05). As a whole, children with EHPVO showed trends for lower α (median 41% vs 49%) and higher θ power than controls (median 41% vs 49% and 29% vs 20%, respectively). MHE affects approximately 50% of children with EHPVO and, therefore, is worthwhile to be investigated. Three simple tools, serum ammonia, quantified EEG, and neuropsychological examination, focused on selective attention, executive function, and short-term visual memory can be used effectively in the evaluation of MHE in this setting.

  7. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    PubMed

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Screening tests for aphasia in patients with stroke: a systematic review.

    PubMed

    El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J

    2017-02-01

    Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.

  9. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  10. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  11. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  12. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  13. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  14. Pap Testing Stages of Adoption among Cambodian Immigrants

    PubMed Central

    Taylor, Victoria M.; Jackson, J. Carey; Yasui, Yutaka; Schwartz, Stephen M.; Kuniyuki, Alan; Fischer, Meredith; Tu, Shin-Ping

    2006-01-01

    Purpose We examined levels of Pap testing and factors associated with screening participation among Cambodian refugees. Methods A community-based, in-person survey was conducted in Seattle during late 1997 and early 1998. Interviews were completed by 413 women; the estimated response rate was 73%. We classified respondents into four Pap testing stages of adoption: precontemplation/contemplation (never screened), relapse (ever screened but did not plan to be screened in the future), action (ever screened and planned to be screened in the future), and maintenance (recently screened and planned to be screened in the future). Bivariate and multivariate techniques were used to examine various factors. Findings About one-quarter (24%) of the respondents has never been screened, and a further 22% had been screened but did not plan to obtain Pap tests in the future. Fifteen percent were in the action stage and 39% were in the maintenance stage. The following factors were independently associated with cervical cancer screening stages: previous physician recommendation; younger age; beliefs about Pap testing for post-menopausal women, screening for sexually inactive women, and regular checkups; provider ethnicity; prenatal care in the US; and problems finding interpreters. Conclusions Our findings confirm low Pap testing rates among Cambodian immigrants, and suggest that targeted interventions should be multifaceted. PMID:11567513

  15. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...

  16. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...

  17. Three-hour analysis of non-invasive foetal sex determination: application of Plexor chemistry.

    PubMed

    Pietropolli, Adalgisa; Capogna, Maria Vittoria; Cascella, Raffaella; Germani, Chiara; Bruno, Valentina; Strafella, Claudia; Sarta, Simona; Ticconi, Carlo; Marmo, Giusy; Gallaro, Sara; Longo, Giuliana; Marsella, Luigi Tonino; Novelli, Antonio; Novelli, Giuseppe; Piccione, Emilio; Giardina, Emiliano

    2016-04-04

    The knowledge of the individual genetic "status" in the prenatal era is particularly relevant in the case of positive family history for genetic diseases, in advanced maternal age and in the general screening for foetal abnormalities. In this context, here, we report an innovative molecular assay which utilizes the cell-free foetal DNA (cffDNA) as a source for the early and fast detection of the foetal sex. The study involved 132 pregnant women in their first 3 months of pregnancy, who agreed to give a blood sample. All the collected samples were immediately subjected to the separation of the plasma, which was utilized for the extraction of the cffDNA. Successively, the extracted cffDNA was analysed by a quantitative PCR (qPCR) method based on Plexor-HY chemistry, which is able to simultaneously identify, quantify and discriminate the autosomal DNA from the sex-linked DNA. Overall, the Plexor-HY assay demonstrated to be sensitive and specific for the determination of low-template DNA, such as the cffDNA. In fact, the Plexor-HY assay has been successfully performed in all the samples, identifying 70 males and 62 females. As the foetal sex can be provided in 120 min just by utilizing a maternal blood sample as cffDNA source, the assay represents a very fast, safe and non-invasive prenatal method. The possibility of determining the foetal sex in the early prenatal life consents the application of our assay as a helpful screening test for subjects and families at risk of sex-linked disorders. Moreover, the early knowledge of the foetal sex may be of great help even for the specialist, who might promptly advise the patients concerning the foetal risk of inheriting sex-linked disorders and the clinical utility of performing an invasive prenatal diagnosis.

  18. RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation

    PubMed Central

    Flore, Leigh Anne; Leon, Eyby; Maher, Tom A.; Milunsky, Jeff M.

    2012-01-01

    Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM. PMID:27625812

  19. RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation.

    PubMed

    Flore, Leigh Anne; Leon, Eyby; Maher, Tom A; Milunsky, Jeff M

    2012-06-01

    Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM.

  20. HPV primary cervical screening in England: Women's awareness and attitudes.

    PubMed

    Patel, Hersha; Moss, Esther L; Sherman, Susan M

    2018-03-09

    Primary human papillomavirus (HPV) cervical screening is due to be implemented in England within the next 2 years; however, the acceptability of HPV testing as the primary screening test is unclear. This study explores women's awareness and attitudes toward HPV testing/screening. Qualitative interviews (semistructured and focus group) were conducted with 46 women (aged 25-65 years) from community and secondary care settings. Data were analyzed by using the inductive-framework method. Women were unaware that cervical screening currently includes HPV testing and lacked HPV-related knowledge. Emotions of shock, fear, and anxiety were reported upon receiving a positive HPV result. For women in long-term relationships, the realization that HPV is a sexually transmitted infection was seen as a barrier to primary HPV testing. Knowledge that HPV testing is a screening test to prevent cervical cancer did not change their attitudes. Women debated the need for continued screening following a negative result. Women feared judgment by the community if they participated with primary HPV screening because they were being tested for a sexually transmitted infection, with the possible attendant perception that they had adopted a high-risk lifestyle in comparison to nonattenders. The acceptability of HPV testing may be a limiting factor in encouraging participation with screening in the future. Copyright © 2018 John Wiley & Sons, Ltd.

  1. A Novel Testing Model for Opportunistic Screening of Pre-Diabetes and Diabetes among U.S. Adults

    PubMed Central

    Zhang, Yurong; Hu, Gang; Zhang, Lu; Mayo, Rachel; Chen, Liwei

    2015-01-01

    Objective The study aim was to evaluate the performance of a novel simultaneous testing model, based on the Finnish Diabetes Risk Score (FINDRISC) and HbA1c, in detecting undiagnosed diabetes and pre-diabetes in Americans. Research Design and Methods This cross-sectional analysis included 3,886 men and women (≥ 20 years) without known diabetes from the U.S. National Health and Nutrition Examination Survey (NHANES) 2005-2010. The FINDRISC was developed based on eight variables (age, BMI, waist circumference, use of antihypertensive drug, history of high blood glucose, family history of diabetes, daily physical activity and fruit & vegetable intake). The sensitivity, specificity, and the receiver operating characteristic (ROC) curve of the testing model were calculated for undiagnosed diabetes and pre-diabetes, determined by oral glucose tolerance test (OGTT). Results The prevalence of undiagnosed diabetes was 7.0% and 43.1% for pre-diabetes (27.7% for isolated impaired fasting glucose (IFG), 5.1% for impaired glucose tolerance (IGT), and 10.3% for having both IFG and IGT). The sensitivity and specificity of using the HbA1c alone was 24.2% and 99.6% for diabetes (cutoff of ≥6.5%), and 35.2% and 86.4% for pre-diabetes (cutoff of ≥5.7%). The sensitivity and specificity of using the FINDRISC alone (cutoff of ≥9) was 79.1% and 48.6% for diabetes and 60.2% and 61.4% for pre-diabetes. Using the simultaneous testing model with a combination of FINDRISC and HbA1c improved the sensitivity to 84.2% for diabetes and 74.2% for pre-diabetes. The specificity for the simultaneous testing model was 48.4% of diabetes and 53.0% for pre-diabetes. Conclusions This simultaneous testing model is a practical and valid tool in diabetes screening in the general U.S. population. PMID:25790106

  2. Risks of Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  3. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. II: Confirmatory analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2010-06-18

    For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Recent trends in digital halftoning

    NASA Astrophysics Data System (ADS)

    Delabastita, Paul A.

    1997-02-01

    Screening is perhaps the oldest form of image processing. The word refers to the mechanical cross line screens that were used at the beginning of this century for the purpose of photomechanical reproduction. Later on, these mechanical screens were replaced by photographic contact screens that enabled significantly improved process control. In the early eighties, the optical screening on graphic arts scanners was replaced by a combination of laser optics and electronic screening. The algorithms, however, were still digital implementations of the original optical methods. The printing needs in the fast growing computer and software industry gave birth to a number of alternative printing technologies such as electrophotographic and inkjet printing. Originally these deices were only designed for printing text, but soon people started experimenting and using them for printing images. The relatively low spatial resolutions of these new devices however made complete review of 'the screening issue' necessary to achieve an acceptable image quality. In this paper a number of recent developments in screening technology are summarized. Special attention is given to the interaction that exists between a halftone screen and the printing devices on which they are rendered including the color mixing behavior. Improved screening techniques are presented that take advantage of modeling the physical behavior of the rendering device.

  5. Irradiation Testing Vehicles for Fast Reactors from Open Test Assemblies to Closed Loops

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sienicki, James J.; Grandy, Christopher

    A review of irradiation testing vehicle approaches and designs that have been incorporated into past Sodium-Cooled Fast Reactors (SFRs) or envisioned for incorporation has been carried out. The objective is to understand the essential features of the approaches and designs so that they can inform test vehicle designs for a future U.S. Fast Test Reactor. Fast test reactor designs examined include EBR-II, FFTF, JOYO, BOR-60, PHÉNIX, JHR, and MBIR. Previous designers exhibited great ingenuity in overcoming design and operational challenges especially when the original reactor plant’s mission changed to an irradiation testing mission as in the EBRII reactor plant. Themore » various irradiation testing vehicles can be categorized as: Uninstrumented open assemblies that fit into core locations; Instrumented open test assemblies that fit into special core locations; Self-contained closed loops; and External closed loops. A special emphasis is devoted to closed loops as they are regarded as a very desirable feature of a future U.S. Fast Test Reactor. Closed loops are an important technology for irradiation of fuels and materials in separate controlled environments. The impact of closed loops on the design of fast reactors is also discussed in this report.« less

  6. GeauxDock: Accelerating Structure-Based Virtual Screening with Heterogeneous Computing

    PubMed Central

    Fang, Ye; Ding, Yun; Feinstein, Wei P.; Koppelman, David M.; Moreno, Juana; Jarrell, Mark; Ramanujam, J.; Brylinski, Michal

    2016-01-01

    Computational modeling of drug binding to proteins is an integral component of direct drug design. Particularly, structure-based virtual screening is often used to perform large-scale modeling of putative associations between small organic molecules and their pharmacologically relevant protein targets. Because of a large number of drug candidates to be evaluated, an accurate and fast docking engine is a critical element of virtual screening. Consequently, highly optimized docking codes are of paramount importance for the effectiveness of virtual screening methods. In this communication, we describe the implementation, tuning and performance characteristics of GeauxDock, a recently developed molecular docking program. GeauxDock is built upon the Monte Carlo algorithm and features a novel scoring function combining physics-based energy terms with statistical and knowledge-based potentials. Developed specifically for heterogeneous computing platforms, the current version of GeauxDock can be deployed on modern, multi-core Central Processing Units (CPUs) as well as massively parallel accelerators, Intel Xeon Phi and NVIDIA Graphics Processing Unit (GPU). First, we carried out a thorough performance tuning of the high-level framework and the docking kernel to produce a fast serial code, which was then ported to shared-memory multi-core CPUs yielding a near-ideal scaling. Further, using Xeon Phi gives 1.9× performance improvement over a dual 10-core Xeon CPU, whereas the best GPU accelerator, GeForce GTX 980, achieves a speedup as high as 3.5×. On that account, GeauxDock can take advantage of modern heterogeneous architectures to considerably accelerate structure-based virtual screening applications. GeauxDock is open-sourced and publicly available at www.brylinski.org/geauxdock and https://figshare.com/articles/geauxdock_tar_gz/3205249. PMID:27420300

  7. GeauxDock: Accelerating Structure-Based Virtual Screening with Heterogeneous Computing.

    PubMed

    Fang, Ye; Ding, Yun; Feinstein, Wei P; Koppelman, David M; Moreno, Juana; Jarrell, Mark; Ramanujam, J; Brylinski, Michal

    2016-01-01

    Computational modeling of drug binding to proteins is an integral component of direct drug design. Particularly, structure-based virtual screening is often used to perform large-scale modeling of putative associations between small organic molecules and their pharmacologically relevant protein targets. Because of a large number of drug candidates to be evaluated, an accurate and fast docking engine is a critical element of virtual screening. Consequently, highly optimized docking codes are of paramount importance for the effectiveness of virtual screening methods. In this communication, we describe the implementation, tuning and performance characteristics of GeauxDock, a recently developed molecular docking program. GeauxDock is built upon the Monte Carlo algorithm and features a novel scoring function combining physics-based energy terms with statistical and knowledge-based potentials. Developed specifically for heterogeneous computing platforms, the current version of GeauxDock can be deployed on modern, multi-core Central Processing Units (CPUs) as well as massively parallel accelerators, Intel Xeon Phi and NVIDIA Graphics Processing Unit (GPU). First, we carried out a thorough performance tuning of the high-level framework and the docking kernel to produce a fast serial code, which was then ported to shared-memory multi-core CPUs yielding a near-ideal scaling. Further, using Xeon Phi gives 1.9× performance improvement over a dual 10-core Xeon CPU, whereas the best GPU accelerator, GeForce GTX 980, achieves a speedup as high as 3.5×. On that account, GeauxDock can take advantage of modern heterogeneous architectures to considerably accelerate structure-based virtual screening applications. GeauxDock is open-sourced and publicly available at www.brylinski.org/geauxdock and https://figshare.com/articles/geauxdock_tar_gz/3205249.

  8. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  9. Automatic analysis of the micronucleus test in primary human lymphocytes using image analysis.

    PubMed

    Frieauff, W; Martus, H J; Suter, W; Elhajouji, A

    2013-01-01

    The in vitro micronucleus test (MNT) is a well-established test for early screening of new chemical entities in industrial toxicology. For assessing the clastogenic or aneugenic potential of a test compound, micronucleus induction in cells has been shown repeatedly to be a sensitive and a specific parameter. Various automated systems to replace the tedious and time-consuming visual slide analysis procedure as well as flow cytometric approaches have been discussed. The ROBIAS (Robotic Image Analysis System) for both automatic cytotoxicity assessment and micronucleus detection in human lymphocytes was developed at Novartis where the assay has been used to validate positive results obtained in the MNT in TK6 cells, which serves as the primary screening system for genotoxicity profiling in early drug development. In addition, the in vitro MNT has become an accepted alternative to support clinical studies and will be used for regulatory purposes as well. The comparison of visual with automatic analysis results showed a high degree of concordance for 25 independent experiments conducted for the profiling of 12 compounds. For concentration series of cyclophosphamide and carbendazim, a very good correlation between automatic and visual analysis by two examiners could be established, both for the relative division index used as cytotoxicity parameter, as well as for micronuclei scoring in mono- and binucleated cells. Generally, false-positive micronucleus decisions could be controlled by fast and simple relocation of the automatically detected patterns. The possibility to analyse 24 slides within 65h by automatic analysis over the weekend and the high reproducibility of the results make automatic image processing a powerful tool for the micronucleus analysis in primary human lymphocytes. The automated slide analysis for the MNT in human lymphocytes complements the portfolio of image analysis applications on ROBIAS which is supporting various assays at Novartis.

  10. Continuous glucose monitoring and its relationship to hemoglobin A1c and oral glucose tolerance testing in obese and prediabetic youth.

    PubMed

    Chan, Christine L; Pyle, Laura; Newnes, Lindsey; Nadeau, Kristen J; Zeitler, Philip S; Kelsey, Megan M

    2015-03-01

    The optimal screening test for diabetes and prediabetes in obese youth is controversial. We examined whether glycosylated hemoglobin (HbA1c) or the oral glucose tolerance test (OGTT) is a better predictor of free-living glycemia as measured by continuous glucose monitoring (CGM). This was a cross-sectional study of youth 10-18 years old, body mass index (BMI) 85th percentile or greater, with diabetes risk factors. Participants (n = 118) with BMI 85th percentile or greater, not on medications for glucose management, were recruited from primary care and pediatric endocrinology clinics around Denver, Colorado. HbA1c, fasting plasma glucose, and 2-hour glucose were collected and all participants wore a blinded CGM for 72 hours. CGM outcomes were determined and descriptive statistics calculated. Performance characteristics at current American Diabetes Association cutpoints were compared with CGM outcomes. CGM data were successfully collected on 98 obese youth. Those with prediabetes had significantly higher average glucose, area under the curve (AUC), peak glucose, and time greater than 120 and greater than 140 mg/dL (P < .01) on CGM than youth with normal HbA1c or OGTT. HbA1c had a greater magnitude of correlation to CGM average glucose, AUC, and minimum glucose; 2-hour glucose had a greater magnitude of correlation to CGM SD, peak glucose, and time greater than 140 and greater than 200 mg/dL. However, there were no overall differences in the strength comparisons between 2-hour glucose and HbA1c correlations to CGM outcomes. In obese youth, HbA1c and 2-hour glucose performed equally well at predicting free-living glycemia on CGM, suggesting that both are valid tests for dysglycemia screening.

  11. Gestational diabetes mellitus: Confusion among medical doctors caused by multiple international criteria.

    PubMed

    Agarwal, Mukesh M; Shah, Syed M; Al Kaabi, Juma; Saquib, Shabnam; Othman, Yusra

    2015-06-01

    The aim of this study was to appraise the current regional practices of screening, diagnosis and follow-up of gestational diabetes mellitus (GDM) because the approach to GDM is frequently inconsistent. A 21-item questionnaire was distributed to physicians taking care of pregnant women in seven hospitals in the United Arab Emirates and one hospital in Oman. Besides assessing their attitudes towards testing for GDM, the questionnaire assessed familiarity with the Hyperglycemia and Pregnancy Outcome study and the International Association of Diabetes in Pregnancy Study Groups GDM guidelines. One hundred and forty-eight (93%) of the 159 questionnaires distributed to the medical doctors (106 [72%] obstetricians and 42 [28%] internists) were returned. For GDM screening, six hospitals used five different tests; two hospitals utilized one single test. For GDM diagnosis, six hospitals employed the 2-h, 75-g oral glucose tolerance test (OGTT) (four different criteria) while two hospitals used the 3-h, 100-g OGTT (single criteria). For post-delivery follow-up, the 2-h, 75-g OGTT and fasting plasma glucose were accepted by 103 (70%) and 38 (26%) of the 148 medical doctors, respectively. Ninety-eight (69%) of 143 responding physicians were aware of the Hyperglycemia and Pregnancy Outcome study, while 85 (61%) of 140 responders were familiar with the guidelines of the International Association of Diabetes in Pregnancy Study Groups; this knowledge was independent of specialty, seniority, academia, years in practice or country trained. Although this study is parochial, its implications are global; that is, further education of caregivers would make the discordant approach to GDM (within and between hospitals) more harmonious and improve the obstetric care of pregnant women. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  12. A new bead-based human platelet antigen antibodies detection assay versus the monoclonal antibody immobilization of platelet antigens assay.

    PubMed

    Porcelijn, Leendert; Huiskes, Elly; Comijs-van Osselen, Ilona; Chhatta, Aniska; Rathore, Vipul; Meyers, Matthew; de Haas, Masja

    2014-06-01

    The performance of a newly developed Luminex bead-based platelet (PLT) antibody detection method (PAKLx) was compared with the monoclonal antibody immobilization of PLT antigens (MAIPA) assay and the LifeScreen Deluxe Luminex bead-based HLA Class I antibody detection method (LMX). Six sera containing anti-human PLT antigen (HPA)-1a (n=2), HPA-1b, HPA-2b, HPA-3a, or HPA-5b were tested in titration. A total of 194 sera, including HPA-1a, -1b, -2a, -2b, -3a, -5a, and -5b antibodies with or without HLA antibodies (n=63); glycoprotein (GP) IV antibodies (n=1); PLT autoantibodies (n=3); HLA antibodies (n=45); and samples with no PLT-reactive antibodies (n=82), were tested in both assays. Comparable levels of sensitivity were obtained for the MAIPA and PAKLx. The PAKLx showed four (6%) false-negative results in 67 sera with HPA or GP-reactive antibodies: anti-HPA-3a (n=1) or anti-HPA-5b (n=3). The PAKLx showed in 10 of the total 194 samples (5%) the presence of antibodies not detected by the MAIPA. This concerned broadly GP-reactive antibodies (n=7), anti-GPIIb/IIIa combined with anti-HPA-3a (n=1), anti-HPA-1a (borderline, n=1), and anti-GPIV (n=1). Testing 175 sera for anti-HLA Class I antibodies in the PAKLx and LMX showed four discrepant results: PAKLx negative and LMX positive, n=3 and n=1, respectively. For the vast majority of the specimens tested (93%) the results of the PAKLx were in concordance with the MAIPA. The PAKLx is a fast, easy to perform, and sensitive PLT antibody screening method. © 2013 AABB.

  13. Fast screening of Bifidobacterium longum sublethal stress conditions in a novel two-stage continuous culture strategy.

    PubMed

    Mozzetti, V; Grattepanche, F; Berger, B; Rezzonico, E; Arigoni, F; Lacroix, C

    2013-06-01

    A central issue in the application of probiotics as food additives is their fastidious production and their sensitivity to many environmental stresses. The importance of inducible cell-protective mechanisms triggered by application of sublethal stresses for survival under stress conditions has been demonstrated. Continuous cultures could be a suitable and more efficient method to test stress factors on one culture instead of several repeated batch cultures. In this study, the application of a two-stage continuous culture of Bifidobacterium longum NCC2705 was investigated. The first reactor was operated under fixed conditions at 37 °C and pH 6.0 and used to produce cells with controlled physiology, mimicking cells in the late exponential growth phase. Stress pretreatment combinations of pH (6.0, 5.0 and 4.0), temperature (37, 45 and 47 °C) and NaCl (0, 5 and 10%) were tested in the second reactor. Of all tested combinations, only those of pH 4.0 significantly decreased cell viability in the second reactor compared to control conditions (37 °C, pH 6.0, 0% NaCl) and, therefore, could not be considered as sublethal stresses. Pretreatments with 5 or 10% NaCl had a negative effect on cell viability after gastric lethal stress. A significant improvement in cell resistance to heat lethal stress (56 °C, 5 min) was observed for cells pretreated at 47 °C. In contrast, heat pretreatment negatively affected cell viability after freeze drying and osmotic lethal stresses. The two-stage continuous culture allowed for efficient screening of several stress pretreatments during the same experiment with up to four different conditions tested per day. Optimal sublethal stress conditions can also be applied for producing cells with traditional batch cultures.

  14. Glucose tolerance status in 510 children and adolescents attending an obesity clinic in Central Italy.

    PubMed

    Brufani, Claudia; Ciampalini, Paolo; Grossi, Armando; Fiori, Rossana; Fintini, Danilo; Tozzi, Alberto; Cappa, Marco; Barbetti, Fabrizio

    2010-02-01

    Childhood obesity is epidemic in developed countries and is accompanied by an increase in the prevalence of type 2 diabetes (T2DM). Establish prevalence of glucose metabolism alterations in a large sample of overweight/obese children and adolescents from Central Italy. The study group included 510 overweight/obese subjects (3-18 yr). Oral glucose tolerance test (OGTT) was performed with glucose and insulin determination. Homeostatic model assessment of insulin resistance (HOMA-IR) and insulin sensitivity index (ISI) were derived from fasting and OGTT measurements. Beta-cell function was estimated by insulinogenic index. Fat mass was measured by dual-energy x-ray absorptiometry. Glucose metabolism alterations were detected in 12.4% of patients. Impaired glucose tolerance (IGT) was the most frequent alteration (11.2%), with a higher prevalence in adolescents than in children (14.8 vs. 4.1%, p < 0.001); silent T2DM was identified in two adolescents (0.4%). HOMA-IR and glucose-stimulated insulin levels were higher in patients with IGT than individuals with normal glucose tolerance (HOMA-IR = 4.4 +/- 2.5 vs. 3.4 +/- 2.3, p = 0.001). Fat mass percentage and insulinogenic index were not different between the two groups. In multivariate analysis, age, fasting glucose, and insulin resistance influenced independently plasma glucose at 120 min of OGTT. Individuals with combined impaired fasting glucose/IGT (IFG/IGT) and T2DM were older and had reduced plasma insulin values at OGTT when compared to patients with simple IGT. Glucose metabolism alterations are frequently found among children and adolescents with overweight/obesity from Central Italy. Age, fasting glucose, and insulin resistance are main predictors of IGT. We suggest the use of OGTT as a screening tool in obese European adolescents.

  15. Impact of state-specific Medicaid reimbursement and eligibility policies on receipt of cancer screening.

    PubMed

    Halpern, Michael T; Romaire, Melissa A; Haber, Susan G; Tangka, Florence K; Sabatino, Susan A; Howard, David H

    2014-10-01

    Although state Medicaid programs cover cancer screening, Medicaid beneficiaries are less likely to be screened for cancer and are more likely to present with tumors of an advanced stage than are those with other insurance. The current study was performed to determine whether state Medicaid eligibility and reimbursement policies affect the receipt of breast, cervical, and colon cancer screening among Medicaid beneficiaries. Cross-sectional regression analyses of 2007 Medicaid data from 46 states and the District of Columbia were performed to examine associations between state-specific Medicaid reimbursement/eligibility policies and receipt of cancer screening. The study sample included individuals aged 21 years to 64 years who were enrolled in fee-for-service Medicaid for at least 4 months. Subsamples eligible for each screening test were: Papanicolaou test among 2,136,511 patients, mammography among 792,470 patients, colonoscopy among 769,729 patients, and fecal occult blood test among 753,868 patients. State-specific Medicaid variables included median screening test reimbursement, income/financial asset eligibility requirements, physician copayments, and frequency of eligibility renewal. Increases in screening test reimbursement demonstrated mixed associations (positive and negative) with the likelihood of receiving screening tests among Medicaid beneficiaries. In contrast, increased reimbursements for office visits were found to be positively associated with the odds of receiving all screening tests examined, including colonoscopy (odds ratio [OR], 1.07; 95% confidence interval [95% CI], 1.06-1.08), fecal occult blood test (OR, 1.09; 95% CI, 1.08-1.10), Papanicolaou test (OR, 1.02; 95% CI, 1.02-1.03), and mammography (OR, 1.02; 95% CI, 1.02-1.03). Effects of other state-specific Medicaid policies varied across the screening tests examined. Increased reimbursement for office visits was consistently associated with an increased likelihood of being screened for cancer, and may be an important policy tool for increasing screening among this vulnerable population. © 2014 American Cancer Society.

  16. Hemochromatosis detection in a health screening program at an Alabama forest products mill.

    PubMed

    Barton, James C; Cheatwood, Susan M; Key, Timothy J; Acton, Ronald T

    2002-08-01

    We analyzed hemochromatosis detection in a 11.5-year multiphasic health screening program at a forest products mill. There were 2199 participants: 2032 Whites (1506 men, 526 women) and 167 African Americans (124 men, 43 women); 85.0% of employees were screened. Iron and transferrin saturation were measured in a serum biochemistry profile on specimens obtained after overnight fasting; ferritin was measured in participants with elevated iron concentrations or transferrin saturation > 48%. Participants with elevated ferritin levels underwent further evaluation. Eight White men were diagnosed to have hemochromatosis (frequency 0.0039 in Whites, 0.0053 in White men). The estimated cost per case detected was $8826. Family members of two participants with hemochromatosis were also diagnosed to have hemochromatosis or iron overload. We conclude that detecting hemochromatosis in a workplace multiphasic health screening program is efficacious and economical.

  17. Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy.

    PubMed

    Astolfo, Alberto; Endrizzi, Marco; Vittoria, Fabio A; Diemoz, Paul C; Price, Benjamin; Haig, Ian; Olivo, Alessandro

    2017-05-19

    X-ray phase contrast imaging (XPCI) is an innovative imaging technique which extends the contrast capabilities of 'conventional' absorption based x-ray systems. However, so far all XPCI implementations have suffered from one or more of the following limitations: low x-ray energies, small field of view (FOV) and long acquisition times. Those limitations relegated XPCI to a 'research-only' technique with an uncertain future in terms of large scale, high impact applications. We recently succeeded in designing, realizing and testing an XPCI system, which achieves significant steps toward simultaneously overcoming these limitations. Our system combines, for the first time, large FOV, high energy and fast scanning. Importantly, it is capable of providing high image quality at low x-ray doses, compatible with or even below those currently used in medical imaging. This extends the use of XPCI to areas which were unpractical or even inaccessible to previous XPCI solutions. We expect this will enable a long overdue translation into application fields such as security screening, industrial inspections and large FOV medical radiography - all with the inherent advantages of the XPCI multimodality.

  18. Porcine Circovirus (PCV) Removal by Q Sepharose Fast Flow Chromatography

    PubMed Central

    Yang, Bin; Wang, Hua; Ho, Cintia; Lester, Philip; Chen, Qi; Neske, Florian; Baylis, Sally A; Blümel, Johannes

    2013-01-01

    The recently discovered contamination of oral rotavirus vaccines led to exposure of millions of infants to porcine circovirus (PCV). PCV was not detected by conventional virus screening tests. Regulatory agencies expect exclusion of adventitious viruses from biological products. Therefore, methods for inactivation/removal of viruses have to be implemented as an additional safety barrier whenever feasible. However, inactivation or removal of PCV is difficult. PCV is highly resistant to widely used physicochemical inactivation procedures. Circoviruses such as PCV are the smallest viruses known and are not expected to be effectively removed by currently-used virus filters due to the small size of the circovirus particles. Anion exchange chromatography such as Q Sepharose® Fast Flow (QSFF) has been shown to effectively remove a range of viruses including parvoviruses. In this study, we investigated PCV1 removal by virus filtration and by QSFF chromatography. As expected, PCV1 could not be effectively removed by virus filtration. However, PCV1 could be effectively removed by QSFF as used during the purification of monoclonal antibodies (mAbs) and a log10 reduction value (LRV) of 4.12 was obtained. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:1464–1471, 2013 PMID:24039195

  19. Fast log P determination by ultra-high-pressure liquid chromatography coupled with UV and mass spectrometry detections.

    PubMed

    Henchoz, Yveline; Guillarme, Davy; Martel, Sophie; Rudaz, Serge; Veuthey, Jean-Luc; Carrupt, Pierre-Alain

    2009-08-01

    Ultra-high-pressure liquid chromatography (UHPLC) systems able to work with columns packed with sub-2 microm particles offer very fast methods to determine the lipophilicity of new chemical entities. The careful development of the most suitable experimental conditions presented here will help medicinal chemists for high-throughput screening (HTS) log P(oct) measurements. The approach was optimized using a well-balanced set of 38 model compounds and a series of 28 basic compounds such as beta-blockers, local anesthetics, piperazines, clonidine, and derivatives. Different organic modifiers and hybrid stationary phases packed with 1.7-microm particles were evaluated in isocratic as well as gradient modes, and the advantages and limitations of tested conditions pointed out. The UHPLC approach offered a significant enhancement over the classical HPLC methods, by a factor 50 in the lipophilicity determination throughput. The hyphenation of UHPLC with MS detection allowed a further increase in the throughput. Data and results reported herein prove that the UHPLC-MS method can represent a progress in the HTS-measurement of lipophilicity due to its speed (at least a factor of 500 with respect to HPLC approaches) and to an extended field of application.

  20. Screening for Syphilis: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D

    2016-06-07

    Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.

  1. Screening for coronary heart disease risk factors in retail pharmacies in Sheffield, 1992.

    PubMed Central

    Allison, C; Page, H; George, S

    1994-01-01

    OBJECTIVE--To investigate the current and likely future provision of screening services for risk factors for coronary heart disease in retail pharmacies in Sheffield. DESIGN--This was a questionnaire survey asking about screening tests currently offered, price charged per test, likely future provision of screening tests, the action respondents would take upon finding an abnormal test result, whether the pharmacy was owner-run, franchised, or part of a commercial chain, and inviting open comments from respondents. SETTING--All retail pharmacy premises on the Sheffield Family Health Services Authority list. RESULTS--Seventy seven responses were obtained to 102 questionnaires distributed. Only nine of these currently offered any screening test other than pregnancy testing, although 37 indicated that they might offer tests in the future. Thirty nine were not offering screening and had no plans to do so. Pharmacies offering or likely to offer screening tests were mainly owner-run. All pharmacists who replied to the question asking about their action upon finding abnormal result (33) reported that they would advise the patient to see a doctor. The most frequent comments made by pharmacists were about the commercial viability of screening in pharmacies and the lack of space available to ensure patient privacy and confidentiality during screening. CONCLUSIONS--Screening in retail pharmacies would probably be a commercial failure unless doctors were able to contract for screening services from pharmacies. Evidence from this study and others, however, leads us to question the desirability of this option. PMID:8189175

  2. Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.

    PubMed

    Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P

    2015-09-01

    To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  4. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  5. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  6. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  7. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  8. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  9. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  10. The relative importance of patient-reported barriers to colorectal cancer screening.

    PubMed

    Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W

    2010-05-01

    Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening

    PubMed Central

    Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.

    2009-01-01

    PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838

  12. Automated sample area definition for high-throughput microscopy.

    PubMed

    Zeder, M; Ellrott, A; Amann, R

    2011-04-01

    High-throughput screening platforms based on epifluorescence microscopy are powerful tools in a variety of scientific fields. Although some applications are based on imaging geometrically defined samples such as microtiter plates, multiwell slides, or spotted gene arrays, others need to cope with inhomogeneously located samples on glass slides. The analysis of microbial communities in aquatic systems by sample filtration on membrane filters followed by multiple fluorescent staining, or the investigation of tissue sections are examples. Therefore, we developed a strategy for flexible and fast definition of sample locations by the acquisition of whole slide overview images and automated sample recognition by image analysis. Our approach was tested on different microscopes and the computer programs are freely available (http://www.technobiology.ch). Copyright © 2011 International Society for Advancement of Cytometry.

  13. Antiprotozoal Activity Profiling of Approved Drugs: A Starting Point toward Drug Repositioning

    PubMed Central

    Kaiser, Marcel; Mäser, Pascal; Tadoori, Leela Pavan; Ioset, Jean-Robert; Brun, Reto

    2015-01-01

    Neglected tropical diseases cause significant morbidity and mortality and are a source of poverty in endemic countries. Only a few drugs are available to treat diseases such as leishmaniasis, Chagas’ disease, human African trypanosomiasis and malaria. Since drug development is lengthy and expensive, a drug repurposing strategy offers an attractive fast-track approach to speed up the process. A set of 100 registered drugs with drug repositioning potential for neglected diseases was assembled and tested in vitro against four protozoan parasites associated with the aforementioned diseases. Several drugs and drug classes showed in vitro activity in those screening assays. The results are critically reviewed and discussed in the perspective of a follow-up drug repositioning strategy where R&D has to be addressed with limited resources. PMID:26270335

  14. Surface plasmon resonance-based molecular detection of Hb S [beta6(A3)Glu-->Val, GAG-->GTG] at the gene level.

    PubMed

    Atalay, Erol O; Ustel, Emre; Yildiz, Sanem; Atalay, Ayfer

    2006-01-01

    The surface plasmon resonance (SPR) approach, being a relatively novel biophysical method, is used to detect many different targets by biomolecular interaction. The SPR system uses optical and evanescent wave phenomenon. This approach does not need any labels, such as enzymes or isotopes, and the monitored interactions are in real time. In DNA-DNA interaction, the SPR approach is Tm-independent. Here we report our preliminary results for the molecular detection of the Hb S (GAG -->GTG) mutation at codon 6 of the human beta-globin gene. Our preliminary results show that the SPR approach could be applied as an inexpensive and fast routine test system for the molecular diagnosis of abnormal hemoglobins (Hbs), especially in premarital screening programs.

  15. Noncontact three-dimensional quantitative profiling of fast aspheric lenses by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Goud, Bujagouni Karthik; Udupa, Dinesh Venkatesh; Prathap, Chilakala; Shinde, Deepak Dilip; Rao, Kompalli Divakar; Sahoo, Naba Kishore

    2016-12-01

    The use of optical coherence tomography (OCT) for noncontact three-dimensional aspheric lens profiling and retrieval of aspheric surface parameters is demonstrated. Two commercially available aspheric lenses with different focal length-to-diameter ratio have been imaged using OCT, and the measured optical path length distribution has been least square fitted with the aspheric lens surface retrieving the radius of curvature, aspheric constant, and conic constants. The refractive index of these lenses has also been measured referencing with a standard Zerodur glass flat. The fitted aspheric surface coefficients of the lenses are in close agreement with the manufacturer's values, thus, envisaging the potential of OCT in rapid screening, testing of aspheric lenses, and other micro-optical components such as those used in illumination optics.

  16. Retinopathy predicts progression of fasting plasma glucose: An Early Diabetes Intervention Program (EDIP) Analysis

    PubMed Central

    Patel, Yash R.; Kirkman, M. Sue; Considine, Robert V; Hannon, Tamara S; Mather, Kieren J

    2017-01-01

    Background Retinopathy is increasingly recognized in prediabetic populations, and may herald increased risk of metabolic worsening. The Early Diabetes Intervention Program (EDIP) evaluated worsening of glycemia in screen-detected Type 2 diabetes, following participants for up to 5 years. Here we have evaluated whether the presence of retinopathy at the time of detection of diabetes was associated with accelerated progression of glycemia. Methods We prospectively studied 194 participants from EDIP with available baseline retinal photographs. Retinopathy was determined at baseline using 7-field fundus photography and defined as an Early Treatment of Diabetic Retinopathy Study Scale grading score of ≥20. Results At baseline, 12% of participants had classical retinal lesions indicating retinopathy. In univariate Cox proportional hazard analysis, the presence of retinopathy at baseline was associated with a doubled risk of progression of fasting plasma glucose (HR 2.02; 95% CI 1.05–3.89). The retinopathy effect was robust to individual adjustment for age and glucose, the most potent determinants of progression in EDIP. Conclusion Retinopathy was associated with increased risk of progression of fasting plasma glucose among adults with screen-detected, early diabetes. Early detection of retinopathy may help individualize more aggressive therapy to prevent progressive metabolic worsening in early diabetes. PMID:28003103

  17. Laboratory tests for diagnosis of food allergy: advantages, disadvantages and future perspectives.

    PubMed

    Moneret-Vautrin, D A; Kanny, G; Frémont, S

    2003-04-01

    Numerous biological tests point to the diagnosis of food sensitization: detection of specific IgEs by Rast techniques, multi-detection assays, immunoblotting, screening of basophil activation (BAT or FAST), assays for leukotriene LTC4 release (CAST), measurement of plasma histamine, serum tryptase, serum ECP, urinary EDN, completed by mannitol-lactulose test evaluating intestinal permeability, assay of fecal IgEs, Rast for specific IgG4. Primary screening for anti-food IgEs by multi-detection assays seeks justification from insufficient clinical data and false positive tests are common in patients sensitized to pollens or latex, on account of in vitro cross reactivities (CR). Multiple CR explain positive Rast to vegetal food allergens in such patients. Biological tests should not be performed as the first line of diagnosis. In vivo sensitisation is assessed by positive prick-tests, demonstrating the bivalence of allergens, as well as the affinity of specific IgEs, two conditions necessary to bridge membrane bound specific IgEs, leading to the release of mediators. Prick-tests are closer to clinical symptoms than biological tests. However, the diagnosis of food allergy is based on standardised oral challenges. Exceptions are high levels of specific IgEs to egg (> 6 kUl/l), peanut (> 15 kUl/l), fish (> 20 kUl/l) and milk (> 32 kUl/l), reaching a 95% predictive positive value. Rast inhibition tests are useful to identify masked allergens in foods. Research developments will have impact on the development of new diagnostic tools: allergen mixes reinforcing a food extract by associated recombinant major allergens, multiple combination of recombinant allergens (chips) or tests with synthetic epitopes aimed a the prediction of recovery. Laboratory tests take place in the decision free for the diagnosis for the food allergy and the follow-up of the levels specific IgEs is a tool to assess outcome and contributes to predict recovery or persistent allergy. Up to now the significance of positive laboratory tests showing the implication of IgEs is at the crossroads of the allergist's and biologist's expertise.

  18. NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Bakke, Victor; Baker, James

    2012-01-01

    While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

  19. 42 CFR 411.15 - Particular services excluded from coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... aneurysms (AAA), cardiovascular disease screening tests, diabetes screening tests, a screening... conditions and limitation specified in § 410.19 of this chapter. (13) In the case of cardiovascular disease screening tests for the early detection of cardiovascular disease or abnormalities associated with an...

  20. The prevalence, risk factors, and screening measure for prediabetes and diabetes among Emirati overweight/obese children and adolescents.

    PubMed

    Al Amiri, Elham; Abdullatif, Mona; Abdulle, Abdishakur; Al Bitar, Nibal; Afandi, Elham Zaki; Parish, Monira; Darwiche, Gassan

    2015-12-24

    The aim of the study was to estimate the prevalence of prediabetes and type 2 diabetes (T2D) among overweight/obese children and adolescents using different diagnostic/screening methods in comparison. We recruited overweight/obese Emirati students; grade 6-12 (age 11-17 years) from 16 government schools in Sharjah (UAE). Anthropometric, demographic, and clinical history data was measured by standard methods. Body mass index (BMI) was categorized according to BMI percentile charts for age and sex - CDC. Capillary fasting blood glucose (FBG) and glycated hemoglobin (HbA1c) were measured by finger prick test, followed by confirmatory oral glucose tolerance tests (OGTT) and venous HbA1c for students with abnormal capillary FBG and/or HbA1c. Of a total of 1034 participants (45 % females) median age 14.7 years, 443 (43 %) students had abnormal screening results. The prevalence of prediabetes and T2D was 5.4 % and 0.87 %, respectively, based on OGTT (gold standard). HbA1c showed a considerable discrepancy regarding the prevalence of prediabetes (21.9 %), but not diabetes. There was a statistically significant difference in the BMI Z-scores between the three different groups of students showing normal glycemic testing, prediabetes and T2D (p = 0.041). Univariate logistic regression analysis showed that glycemic status was significantly associated with family history of T2D first-degree relatives [OR 1.87: 95 % CI: 1.04-3.36; P = 0.036], parents employment [OR 1.79: 95 % CI: 1.06-3.02; P = 0.029] and levels of triglycerides [OR 2.28: 95 % CI: 1.11-4.68; P = 0.024]. The prevalence of prediabetes and diabetes was high among overweight/obese Emirati children and adolescents. The numbers for prediabetes were considerably higher when using HbA1c as compared to OGTT. Overall adiposity, family history of T2D, employment and high levels of triglycerides were risk factors associated with abnormal glycemic testing.

Top