Sample records for screening test performances

  1. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  2. Age-specific performance of careHPV versus Papanicolaou and visual inspection of cervix with acetic acid testing in a primary cervical cancer screening.

    PubMed

    Labani, Satyanarayana; Asthana, Smita

    2016-01-01

    Human papillomavirus (HPV) is recommended as a primary screening tool for cervical screening. Assessment of age-specific performance of newer HPV careHPV DNA testing is important as risk of cervical intraepithelial neoplasia (CIN) varies at different ages. We aim to evaluate careHPV in comparison to Papanicolaou (Pap) test and visual inspection of the cervix with acetic acid (VIA) cervical screening tests for the detection of high-grade CIN. The cross sectional study was conducted in a rural population of North India. Ever-married women 30-59 years of age were invited for screening by careHPV (self-collected vaginal and physician-collected cervical samples), Pap test and VIA. Associations for trend in age for detecting histological-confirmed CINII+ and CINIII+ for each screening test were evaluated. Age-specific association with each screening test was evaluated. Of a total of 7761 women invited, 5032 were screened and analysis was performed on 4658 with all screen test results. No significant (p>0.05) association of age for any screening test in the detection of CINII+ or CINIII+ was observed. For the older age group, cervical HPV (CHPV) showed high sensitivity and specificity for CINII+ detection. Specificity of CHPV or vaginal HPV (VHPV) was equal or higher than Pap in all age groups. Cervical screening options of CHPV or VHPV, or Pap, performed equally in the younger age group while CHPV might be an option for all ages in the detection of high-grade CIN. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Development and verification of a model for estimating the screening utility in the detection of PCBs in transformer oil.

    PubMed

    Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya

    2014-01-01

    A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.

  4. [Primary care screening of problems in the elderly and a proposal for a screening protocol with a multidimensional approach].

    PubMed

    Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele

    2016-07-21

    The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.

  5. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  6. [Comparison of screening performance between primary high-risk HPV screening and high-risk HPV screening plus liquid-based cytology cotesting in diagnosis of cervical precancerous or cancerous lesions].

    PubMed

    Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H

    2018-05-06

    Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, P< 0.001), and the specificity were 86.2% and 78.8% (χ(2)=2 067.00, P< 0.001), respectively. Areas under the receiver operating characteristic (ROC) curve (AUC) showed that the primary HR-HPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, P< 0.001). Compared with primary HR-HPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, P< 0.001) and the number of colposcopy examination for detecting per CIN2+ (5.4 and 7.6, respectively).In the group aged 25-29, the colposcopy referral rates was 8.7 (10.9%(199 cases) vs 1.3%(23 cases)) times as much as the detection rate of primary HR-HPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.

  7. The performance of the SEPT9 gene methylation assay and a comparison with other CRC screening tests: A meta-analysis.

    PubMed

    Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin

    2017-06-08

    The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.

  8. MUSCULOSKELETAL SCREENING AND FUNCTIONAL TESTING: CONSIDERATIONS FOR BASKETBALL ATHLETES.

    PubMed

    Bird, Stephen P; Markwick, William J

    2016-10-01

    Youth participation in basketball is on the rise, with basketball one of the top five participation sports in Australia. With increased participation there is a need for greater awareness of the importance of the pre-participation examination, including musculoskeletal screening and functional performance testing as part of a multidisciplinary approach to reducing the risk for future injuries. As majority of all basketball injuries affect the lower extremities, pre-participation musculoskeletal screening and functional performance testing should assess fundamental movement qualities throughout the kinetic chain with an emphasis on lower extremity force characteristics, specifically eccentric loading tasks. Thus, the purpose of this clinical commentary is to review the existing literature elucidating pre-participation musculoskeletal screening and functional performance tests that can be used as a framework for rehabilitation professionals in assessing basketball athletes' readiness to safely perform the movement demands of their sport. Relevant articles published between 2000 and 2016 using the search terms 'musculoskeletal screening', 'functional testing', 'youth athletes', and 'basketball' were identified using MEDLINE. From a basketball-specific perspective, several relevant musculoskeletal assessments were identified, including: the Functional Hop Test Combination, the Landing Error Scoring System, the Tuck Jump Assessment, the Weight-Bearing Lunge Test, and the Star Excursion Balance Test. Each of these assessments creates movement demands that allow for easy identification of inefficient and/or compensatory movement tendencies. A basic understanding of musculoskeletal deficits including bilateral strength and flexibility imbalances, lower crossed syndrome, and dominance-related factors are key components in determination of injury risk. Assessment of sport-specific movement demands through musculoskeletal screening and functional performance testing is essential for rehabilitation professionals to determine movement competency during performance of fundamental movements related to basketball performance. Youth athletes represent a unique population due to their developing musculoskeletal and neuromuscular systems and should undergo pre-participation musculoskeletal screening for identification of movement limitations. Such an approach to musculoskeletal screening and functional performance may assist in identifying injury risk and also be useful at the end of rehabilitation in determining readiness to return to sport models. Level 5.

  9. Evaluation of a standard test method for screening fuels in soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorini, S.S.; Schabron, J.F.

    1996-12-31

    A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less

  10. The performance of cable braids and terminations to lightning induced transients

    NASA Technical Reports Server (NTRS)

    Crofts, David

    1991-01-01

    The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.

  11. NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Bakke, Victor; Baker, James

    2012-01-01

    While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

  12. 49 CFR 1546.407 - Training, testing, and knowledge of individuals who perform screening functions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Training, testing, and knowledge of individuals... Carrier Conducts Screening § 1546.407 Training, testing, and knowledge of individuals who perform... test prescribed by TSA. (f) Knowledge requirements. Each foreign air carrier must ensure that...

  13. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  14. The time course of cancer detection performance

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, Sian; Clarke, Aileen; Wallis, Matthew; Wheaton, Margot; Duncan, Alison; Gale, Alastair G.

    2011-03-01

    The purpose of this study was to measure how mammography readers' performance varies with time of day and time spent reading. This was investigated in screening practice and when reading an enriched case set. In screening practice records of time and date that each case was read, along with outcome (whether the woman was recalled for further tests, and biopsy results where performed) was extracted from records from one breast screening centre in UK (4 readers). Patterns of performance with time spent reading was also measured using an enriched test set (160 cases, 41% malignant, read three times by eight radiologists). Recall rates varied with time of day, with different patterns for each reader. Recall rates decreased as the reading session progressed both when reading the enriched test set and in screening practice. Further work is needed to expand this work to a greater number of breast screening centres, and to determine whether these patterns of performance over time can be used to optimize overall performance.

  15. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  16. The cost-effectiveness of screening for colorectal cancer.

    PubMed

    Telford, Jennifer J; Levy, Adrian R; Sambrook, Jennifer C; Zou, Denise; Enns, Robert A

    2010-09-07

    Published decision analyses show that screening for colorectal cancer is cost-effective. However, because of the number of tests available, the optimal screening strategy in Canada is unknown. We estimated the incremental cost-effectiveness of 10 strategies for colorectal cancer screening, as well as no screening, incorporating quality of life, noncompliance and data on the costs and benefits of chemotherapy. We used a probabilistic Markov model to estimate the costs and quality-adjusted life expectancy of 50-year-old average-risk Canadians without screening and with screening by each test. We populated the model with data from the published literature. We calculated costs from the perspective of a third-party payer, with inflation to 2007 Canadian dollars. Of the 10 strategies considered, we focused on three tests currently being used for population screening in some Canadian provinces: low-sensitivity guaiac fecal occult blood test, performed annually; fecal immunochemical test, performed annually; and colonoscopy, performed every 10 years. These strategies reduced the incidence of colorectal cancer by 44%, 65% and 81%, and mortality by 55%, 74% and 83%, respectively, compared with no screening. These strategies generated incremental cost-effectiveness ratios of $9159, $611 and $6133 per quality-adjusted life year, respectively. The findings were robust to probabilistic sensitivity analysis. Colonoscopy every 10 years yielded the greatest net health benefit. Screening for colorectal cancer is cost-effective over conventional levels of willingness to pay. Annual high-sensitivity fecal occult blood testing, such as a fecal immunochemical test, or colonoscopy every 10 years offer the best value for the money in Canada.

  17. Colorectal cancer screening: Estimated future colonoscopy need and current volume and capacity.

    PubMed

    Joseph, Djenaba A; Meester, Reinier G S; Zauber, Ann G; Manninen, Diane L; Winges, Linda; Dong, Fred B; Peaker, Brandy; van Ballegooijen, Marjolein

    2016-08-15

    In 2014, a national campaign was launched to increase colorectal cancer (CRC) screening rates in the United States to 80% by 2018; it is unknown whether there is sufficient colonoscopy capacity to reach this goal. This study estimated the number of colonoscopies needed to screen 80% of the eligible population with fecal immunochemical testing (FIT) or colonoscopy and determined whether there was sufficient colonoscopy capacity to meet the need. The Microsimulation Screening Analysis-Colon model was used to simulate CRC screening test use in the United States (2014-2040); the implementation of a national screening program in 2014 with FIT or colonoscopy with 80% participation was assumed. The 2012 Survey of Endoscopic Capacity (SECAP) estimated the number of colonoscopies that were performed and the number that could be performed. If a national screening program started in 2014, by 2024, approximately 47 million FIT procedures and 5.1 million colonoscopies would be needed annually to screen the eligible population with a program using FIT as the primary screening test; approximately 11 to 13 million colonoscopies would be needed annually to screen the eligible population with a colonoscopy-only screening program. According to the SECAP survey, an estimated 15 million colonoscopies were performed in 2012, and an additional 10.5 million colonoscopies could be performed. The estimated colonoscopy capacity is sufficient to screen 80% of the eligible US population with FIT, colonoscopy, or a mix of tests. Future analyses should take into account the geographic distribution of colonoscopy capacity. Cancer 2016;122:2479-86. © 2016 American Cancer Society. © 2016 American Cancer Society.

  18. 49 CFR 1544.407 - Training, testing, and knowledge of individuals who perform screening functions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Training, testing, and knowledge of individuals... Qualifications When the Aircraft Operator Performs Screening § 1544.407 Training, testing, and knowledge of... on-the-job training test prescribed by TSA. (f) Knowledge requirements. Each aircraft operator must...

  19. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    NASA Technical Reports Server (NTRS)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  20. Evaluation of Five Chromogenic Agar Media and the Rosco Rapid Carb Screen Kit for Detection and Confirmation of Carbapenemase Production in Gram-Negative Bacilli

    PubMed Central

    Gilmour, Matthew W.; DeGagne, Pat; Nichol, Kim; Karlowsky, James A.

    2014-01-01

    An efficient workflow to screen for and confirm the presence of carbapenemase-producing Gram-negative bacilli was developed by evaluating five chromogenic screening agar media and two confirmatory assays, the Rapid Carb screen test (Rosco Diagnostica A/S, Taastrup, Denmark) and the modified Hodge test. A panel of 150 isolates was used, including 49 carbapenemase-producing isolates representing a variety of β-lactamase enzyme classes. An evaluation of analytical performance, assay cost, and turnaround time indicated that the preferred workflow (screening test followed by confirmatory testing) was the chromID Carba agar medium (bioMérieux, Marcy l'Étoile, France), followed by the Rapid Carb screen test, yielding a combined sensitivity of 89.8% and a specificity of 100%. As an optional component of the workflow, a determination of carbapenemase gene class via molecular means could be performed subsequent to confirmatory testing. PMID:25355764

  1. MUSCULOSKELETAL SCREENING AND FUNCTIONAL TESTING: CONSIDERATIONS FOR BASKETBALL ATHLETES

    PubMed Central

    Markwick, William J.

    2016-01-01

    Background and Purpose Youth participation in basketball is on the rise, with basketball one of the top five participation sports in Australia. With increased participation there is a need for greater awareness of the importance of the pre-participation examination, including musculoskeletal screening and functional performance testing as part of a multidisciplinary approach to reducing the risk for future injuries. As majority of all basketball injuries affect the lower extremities, pre-participation musculoskeletal screening and functional performance testing should assess fundamental movement qualities throughout the kinetic chain with an emphasis on lower extremity force characteristics, specifically eccentric loading tasks. Thus, the purpose of this clinical commentary is to review the existing literature elucidating pre-participation musculoskeletal screening and functional performance tests that can be used as a framework for rehabilitation professionals in assessing basketball athletes’ readiness to safely perform the movement demands of their sport. Methods Relevant articles published between 2000 and 2016 using the search terms ‘musculoskeletal screening’, ‘functional testing’, ‘youth athletes’, and ‘basketball’ were identified using MEDLINE. From a basketball-specific perspective, several relevant musculoskeletal assessments were identified, including: the Functional Hop Test Combination, the Landing Error Scoring System, the Tuck Jump Assessment, the Weight-Bearing Lunge Test, and the Star Excursion Balance Test. Each of these assessments creates movement demands that allow for easy identification of inefficient and/or compensatory movement tendencies. A basic understanding of musculoskeletal deficits including bilateral strength and flexibility imbalances, lower crossed syndrome, and dominance-related factors are key components in determination of injury risk. Discussion Assessment of sport-specific movement demands through musculoskeletal screening and functional performance testing is essential for rehabilitation professionals to determine movement competency during performance of fundamental movements related to basketball performance. Youth athletes represent a unique population due to their developing musculoskeletal and neuromuscular systems and should undergo pre-participation musculoskeletal screening for identification of movement limitations. Such an approach to musculoskeletal screening and functional performance may assist in identifying injury risk and also be useful at the end of rehabilitation in determining readiness to return to sport models. Level of Evidence Level 5 PMID:27757291

  2. The price of performance: a cost and performance analysis of the implementation of cell-free fetal DNA testing for Down syndrome in Ontario, Canada.

    PubMed

    Okun, N; Teitelbaum, M; Huang, T; Dewa, C S; Hoch, J S

    2014-04-01

    To examine the cost and performance implications of introducing cell-free fetal DNA (cffDNA) testing within modeled scenarios in a publicly funded Canadian provincial Down syndrome (DS) prenatal screening program. Two clinical algorithms were created: the first to represent the current screening program and the second to represent one that incorporates cffDNA testing. From these algorithms, eight distinct scenarios were modeled to examine: (1) the current program (no cffDNA), (2) the current program with first trimester screening (FTS) as the nuchal translucency-based primary screen (no cffDNA), (3) a program substituting current screening with primary cffDNA, (4) contingent cffDNA with current FTS performance, (5) contingent cffDNA at a fixed price to result in overall cost neutrality,(6) contingent cffDNA with an improved detection rate (DR) of FTS, (7) contingent cffDNA with higher uptake of FTS, and (8) contingent cffDNA with optimized FTS (higher uptake and improved DR). This modeling study demonstrates that introducing contingent cffDNA testing improves performance by increasing the number of cases of DS detected prenatally, and reducing the number of amniocenteses performed and concomitant iatrogenic pregnancy loss of pregnancies not affected by DS. Costs are modestly increased, although the cost per case of DS detected is decreased with contingent cffDNA testing. Contingent models of cffDNA testing can improve overall screening performance while maintaining the provision of an 11- to 13-week scan. Costs are modestly increased, but cost per prenatally detected case of DS is decreased. © 2013 John Wiley & Sons, Ltd.

  3. First-trimester contingent screening for trisomies 21, 18 and 13 by biomarkers and maternal blood cell-free DNA testing.

    PubMed

    Nicolaides, K H; Syngelaki, A; Poon, L C; Gil, M M; Wright, D

    2014-01-01

    To examine potential performance of screening for trisomies by cell-free (cf) DNA testing in maternal blood contingent on results of first-line testing by combinations of fetal translucency thickness (NT), fetal heart rate (FHR), ductus venosus pulsatility index (DV PIV), and serum-free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PLGF) and α-fetoprotein (AFP). Performance was estimated for firstly, screening by cfDNA in all pregnancies and secondly, cfDNA testing contingent on results of first-line testing by combinations of ultrasound and biochemical markers. In first-line screening by cfDNA testing, the detection rate for trisomy 21 and trisomies 18 or 13 would be 99 and 96%, respectively, after invasive testing in 1% of the population. In contingent screening, a detection rate of 98% for trisomy 21 and 96% for trisomy 18 or 13, at an invasive testing rate of 0.7%, can be achieved by carrying out cfDNA testing in about 35, 20 and 11% of cases identified by first-line screening with the combined test alone (age, NT, FHR, β-hCG, PAPP-A), the combined test plus PLGF and AFP and the combined test plus PLGF, AFP and DV PIV, respectively. Effective first-trimester screening for trisomies can be achieved by contingent screening incorporating biomarkers and cfDNA testing. © 2013 S. Karger AG, Basel.

  4. Fitness for duty: A 3 minute version of the Psychomotor Vigilance Test predicts fatigue related declines in luggage screening performance

    PubMed Central

    Basner, Mathias; Rubinstein, Joshua

    2011-01-01

    Objective To evaluate the ability of a 3-min Psychomotor Vigilance Test (PVT) to predict fatigue related performance decrements on a simulated luggage screening task (SLST). Methods Thirty-six healthy non-professional subjects (mean age 30.8 years, 20 female) participated in a 4 day laboratory protocol including a 34 hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Results Eleven and 20 lapses (355 ms threshold) on the PVT optimally divided SLST performance into high, medium, and low performance bouts with significantly decreasing threat detection performance A′. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. Conclusions The 3 min PVT was able to predict performance on a simulated luggage screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments. PMID:21912278

  5. Fitness for duty: a 3-minute version of the Psychomotor Vigilance Test predicts fatigue-related declines in luggage-screening performance.

    PubMed

    Basner, Mathias; Rubinstein, Joshua

    2011-10-01

    To evaluate the ability of a 3-minute Psychomotor Vigilance Test (PVT) to predict fatigue-related performance decrements on a simulated luggage-screening task (SLST). Thirty-six healthy nonprofessional subjects (mean age = 30.8 years, 20 women) participated in a 4-day laboratory protocol including a 34-hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Eleven and 20 lapses (355-ms threshold) on the PVT optimally divided SLST performance into high-, medium-, and low-performance bouts with significantly decreasing threat detection performance A'. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. The 3-minute PVT was able to predict performance on a simulated luggage-screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments.

  6. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    PubMed

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  7. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia

    PubMed Central

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-01-01

    Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612

  8. Auto-Thermal Reforming of Jet-A Fuel over Commercial Monolith Catalysts: MicroReactor Evaluation and Screening Test Results

    NASA Technical Reports Server (NTRS)

    Yen, Judy C. H.; Tomsik, Thomas M.

    2004-01-01

    This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.

  9. Evaluation of staff performance and interpretation of the screening program for prevention of thalassemia.

    PubMed

    Prommetta, Simaporn; Sanchaisuriya, Kanokwan; Fucharoen, Goonnapa; Yamsri, Supawadee; Chaiboonroeng, Attawut; Fucharoen, Supan

    2017-06-15

    Thalassemia screening program has been implemented for years in Southeast Asia, but no external quality assessment program has been established. We have developed and initiated the proficiency testing (PT) program for the first time in Thailand with the aim to assess the screening performance of laboratory staff and their competency in interpretation of the screening results. Three PT cycles per year were organized. From the first to the third cycle of the PT scheme, a total number of participant laboratories increased from 59 to 67. In each cycle, 2 PT items (assigned as blood samples of the couple) were provided. Performance evaluation was based on the accuracy of screening results, i.e . mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH) and the dichlorophenolindophenol (DCIP) test for haemoglobin E, including the competency in interpretation of screening results and assessment of foetal risk. Performance was assessed by comparing the participants' result against the assigned value. Of all 3 cycles, most laboratories reported acceptable MCV and MCH values. From the first to the third cycle, incorrect DCIP test and misinterpretation rates were decreased while incorrect risk assessment varied by cycle to cycle. Combining the accuracy of thalassemia screening and the competency in interpretation and risk assessment, approximately half of participants showed excellent performance. Improved performance observed in many laboratories reflects the achievement and benefit of the PT program which should be regularly provided.

  10. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  11. Evaluation of a 5-Marker Blood Test for Colorectal Cancer Early Detection in a Colorectal Cancer Screening Setting.

    PubMed

    Werner, Simone; Krause, Friedemann; Rolny, Vinzent; Strobl, Matthias; Morgenstern, David; Datz, Christian; Chen, Hongda; Brenner, Hermann

    2016-04-01

    In initial studies that included colorectal cancer patients undergoing diagnostic colonoscopy, we had identified a serum marker combination able to detect colorectal cancer with similar diagnostic performance as fecal immunochemical test (FIT). In this study, we aimed to validate the results in participants of a large colorectal cancer screening study conducted in the average-risk, asymptomatic screening population. We tested serum samples from 1,200 controls, 420 advanced adenoma patients, 4 carcinoma in situ patients, and 36 colorectal cancer patients with a 5-marker blood test [carcinoembryonic antigen (CEA)+anti-p53+osteopontin+seprase+ferritin]. The diagnostic performance of individual markers and marker combinations was assessed and compared with stool test results. AUCs for the detection of colorectal cancer and advanced adenomas with the 5-marker blood test were 0.78 [95% confidence interval (CI), 0.68-0.87] and 0.56 (95% CI, 0.53-0.59), respectively, which now is comparable with guaiac-based fecal occult blood test (gFOBT) but inferior to FIT. With cutoffs yielding specificities of 80%, 90%, and 95%, the sensitivities for the detection of colorectal cancer were 64%, 50%, and 42%, and early-stage cancers were detected as well as late-stage cancers. For osteopontin, seprase, and ferritin, the diagnostic performance in the screening setting was reduced compared with previous studies in diagnostic settings while CEA and anti-p53 showed similar diagnostic performance in both settings. Performance of the 5-marker blood test under screening conditions is inferior to FIT even though it is still comparable with the performance of gFOBT. CEA and anti-p53 could contribute to the development of a multiple marker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.

  12. Transient evoked oto-acoustic emission screening in newborns in Bogotá, Colombia: a retrospective study.

    PubMed

    Rojas, Jorge A; Bernal, Jaime E; García, Mary A; Zarante, Ignacio; Ramírez, Natalia; Bernal, Constanza; Gelvez, Nancy; Tamayo, Marta L

    2014-10-01

    The aim of this study was to investigate the characteristics and performance of transient evoked oto-acoustic emission (TEOAE) hearing screening in newborns in Colombia, and analyze all possible variables and factors affecting the results. An observational, descriptive and retrospective study with bivariate analysis was performed. The study population consisted of 56,822 newborns evaluated at the private institution, PREGEN. TEOAE testing was carried out as a pediatric hearing screening test from December 2003 to March 2012. The database from PREGEN was revised, and the protocol for evaluation included the same screening test performed twice. Demographic characteristics were recorded and the newborn's background was evaluated. Basic statistics of the qualitative and quantitative variables, and statistical analysis were obtained using the chi-square test. Of the 56,822 records examined, 0.28% were classed as abnormal, which corresponded to a prevalence of 1 in 350. In the screened newborns, 0.08% had a major abnormality or other clinical condition diagnosed, and 0.29% reported a family history of hearing loss. A prevalence of 6.7 in 10,000 was obtained for microtia, which is similar to the 6.4 in 10,000 previously reported in Colombia (database of the Latin-American Collaborative Study of Congenital Malformations - ECLAMC). Statistical analysis demonstrated an association between presenting with a major anomaly and a higher frequency of abnormal results on both TEOAE tests. Newborns in Colombia do not currently undergo screening for the early detection of hearing impairment. The results from this study suggest TEOAE screening tests, when performed twice, are able to detect hearing abnormalities in newborns. This highlights the need to improve the long-term evaluation and monitoring of patients in Colombia through diagnostic tests, and to provide tests that are both sensitive and specific. Furthermore, the use of TEOAE screening is justified by the favorable cost: benefit ratio demonstrated in many countries worldwide. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Breast Cancer Screening (PDQ®)—Patient Version

    Cancer.gov

    Breast cancer screening is performed using mammogram, clinical breast exam (CBE), and MRI (magnetic resonance imaging) tests. Learn about these and other tests that have been studied to detect or screen for breast cancer in this expert-reviewed and evidence-based summary.

  14. Agar dilution and agar screen with cefoxitin and oxacillin: what is known and what is unknown in detection of meticillin-resistant Staphylococcus aureus.

    PubMed

    Perez, Leandro Reus Rodrigues; Dias, Cícero; d'Azevedo, Pedro Alves

    2008-08-01

    In this study we evaluated the performance of the oxacillin agar screen test, and agar dilution tests using cefoxitin and oxacillin antimicrobials, to detect meticillin resistance in Staphylococcus aureus isolates. The presence of the mecA gene, detected by PCR, was used as the standard to which agar screen and agar dilution tests were compared. The best performance was obtained using the agar dilution test (99.4 % accuracy) with breakpoints of 4 mug ml(-1) for oxacillin and 8 mug ml(-1) for cefoxitin, and using the oxacillin agar screen test. Also, a strong correlation between MIC values of cefoxitin and oxacillin permits the use of either drug for detection of meticillin resistance.

  15. Molecular HIV screening.

    PubMed

    Bourlet, Thomas; Memmi, Meriam; Saoudin, Henia; Pozzetto, Bruno

    2013-09-01

    Nuclear acid testing is more and more used for the diagnosis of infectious diseases. This paper focuses on the use of molecular tools for HIV screening. The term 'screening' will be used under the meaning of first-line HIV molecular techniques performed on a routine basis, which excludes HIV molecular tests designed to confirm or infirm a newly discovered HIV-seropositive patient or other molecular tests performed for the follow-up of HIV-infected patients. The following items are developed successively: i) presentation of the variety of molecular tools used for molecular HIV screening, ii) use of HIV molecular tools for the screening of blood products, iii) use of HIV molecular tools for the screening of organs and tissue from human origin, iv) use of HIV molecular tools in medically assisted procreation and v) use of HIV molecular tools in neonates from HIV-infected mothers.

  16. Impact of state-specific Medicaid reimbursement and eligibility policies on receipt of cancer screening.

    PubMed

    Halpern, Michael T; Romaire, Melissa A; Haber, Susan G; Tangka, Florence K; Sabatino, Susan A; Howard, David H

    2014-10-01

    Although state Medicaid programs cover cancer screening, Medicaid beneficiaries are less likely to be screened for cancer and are more likely to present with tumors of an advanced stage than are those with other insurance. The current study was performed to determine whether state Medicaid eligibility and reimbursement policies affect the receipt of breast, cervical, and colon cancer screening among Medicaid beneficiaries. Cross-sectional regression analyses of 2007 Medicaid data from 46 states and the District of Columbia were performed to examine associations between state-specific Medicaid reimbursement/eligibility policies and receipt of cancer screening. The study sample included individuals aged 21 years to 64 years who were enrolled in fee-for-service Medicaid for at least 4 months. Subsamples eligible for each screening test were: Papanicolaou test among 2,136,511 patients, mammography among 792,470 patients, colonoscopy among 769,729 patients, and fecal occult blood test among 753,868 patients. State-specific Medicaid variables included median screening test reimbursement, income/financial asset eligibility requirements, physician copayments, and frequency of eligibility renewal. Increases in screening test reimbursement demonstrated mixed associations (positive and negative) with the likelihood of receiving screening tests among Medicaid beneficiaries. In contrast, increased reimbursements for office visits were found to be positively associated with the odds of receiving all screening tests examined, including colonoscopy (odds ratio [OR], 1.07; 95% confidence interval [95% CI], 1.06-1.08), fecal occult blood test (OR, 1.09; 95% CI, 1.08-1.10), Papanicolaou test (OR, 1.02; 95% CI, 1.02-1.03), and mammography (OR, 1.02; 95% CI, 1.02-1.03). Effects of other state-specific Medicaid policies varied across the screening tests examined. Increased reimbursement for office visits was consistently associated with an increased likelihood of being screened for cancer, and may be an important policy tool for increasing screening among this vulnerable population. © 2014 American Cancer Society.

  17. Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven V.

    2005-01-01

    Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

  18. Outcomes of transient evoked otoacoustic emission testing in 6-year-old school children: a comparison with pure tone screening and tympanometry.

    PubMed

    Driscoll, C; Kei, J; McPherson, B

    2001-01-01

    (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at > or =1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery.

  19. Rapid review of cognitive screening instruments in MCI: proposal for a process-based approach modification of overlapping tasks in select widely used instruments.

    PubMed

    Díaz-Orueta, Unai; Blanco-Campal, Alberto; Burke, Teresa

    2018-05-01

    ABSTRACTBackground:A detailed neuropsychological assessment plays an important role in the diagnostic process of Mild Cognitive Impairment (MCI). However, available brief cognitive screening tests for this clinical population are administered and interpreted based mainly, or exclusively, on total achievement scores. This score-based approach can lead to erroneous clinical interpretations unless we also pay attention to the test taking behavior or to the type of errors committed during test performance. The goal of the current study is to perform a rapid review of the literature regarding cognitive screening tools for dementia in primary and secondary care; this will include revisiting previously published systematic reviews on screening tools for dementia, extensive database search, and analysis of individual references cited in selected studies. A subset of representative screening tools for dementia was identified that covers as many cognitive functions as possible. How these screening tools overlap with each other (in terms of the cognitive domains being measured and the method used to assess them) was examined and a series of process-based approach (PBA) modifications for these overlapping features was proposed, so that the changes recommended in relation to one particular cognitive task could be extrapolated to other screening tools. It is expected that future versions of cognitive screening tests, modified using a PBA, will highlight the benefits of attending to qualitative features of test performance when trying to identify subtle features suggestive of MCI and/or dementia.

  20. Corrosion testing of candidates for the alkaline fuel cell cathode

    NASA Technical Reports Server (NTRS)

    Singer, Joseph; Fielder, William L.

    1989-01-01

    Current/voltage data was obtained for specially made corrosion electrodes of some oxides and of gold materials for the purpose of developing a screening test of catalysts and supports for use at the cathode of the alkaline fuel cell. The data consists of measurements of current at fixed potentials and cyclic voltammograms. These data will have to be correlated with longtime performance data in order to fully evaluate this approach to corrosion screening. Corrosion test screening of candidates for the oxygen reduction electrode of the alkaline fuel cell was applied to two substances, the pyrochlore Pb2Ru2O6.5 and the spinel NiCo2O4. The substrate gold screen and a sample of the IFC Orbiter Pt-Au performance electrode were included as blanks. The pyrochlore data indicate relative stability, although nothing yet can be said about long term stability. The spinel was plainly unstable. For this type of testing to be validated, comparisons will have to be made with long term performance tests.

  1. Is breast compression associated with breast cancer detection and other early performance measures in a population-based breast cancer screening program?

    PubMed

    Moshina, Nataliia; Sebuødegård, Sofie; Hofvind, Solveig

    2017-06-01

    We aimed to investigate early performance measures in a population-based breast cancer screening program stratified by compression force and pressure at the time of mammographic screening examination. Early performance measures included recall rate, rates of screen-detected and interval breast cancers, positive predictive value of recall (PPV), sensitivity, specificity, and histopathologic characteristics of screen-detected and interval breast cancers. Information on 261,641 mammographic examinations from 93,444 subsequently screened women was used for analyses. The study period was 2007-2015. Compression force and pressure were categorized using tertiles as low, medium, or high. χ 2 test, t tests, and test for trend were used to examine differences between early performance measures across categories of compression force and pressure. We applied generalized estimating equations to identify the odds ratios (OR) of screen-detected or interval breast cancer associated with compression force and pressure, adjusting for fibroglandular and/or breast volume and age. The recall rate decreased, while PPV and specificity increased with increasing compression force (p for trend <0.05 for all). The recall rate increased, while rate of screen-detected cancer, PPV, sensitivity, and specificity decreased with increasing compression pressure (p for trend <0.05 for all). High compression pressure was associated with higher odds of interval breast cancer compared with low compression pressure (1.89; 95% CI 1.43-2.48). High compression force and low compression pressure were associated with more favorable early performance measures in the screening program.

  2. Students as Technicians: Screening Newborns for Cystic Fibrosis

    ERIC Educational Resources Information Center

    Gusky, Sharon

    2014-01-01

    In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…

  3. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    PubMed

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  4. Cost-effectiveness analysis of the optimal threshold of an automated immunochemical test for colorectal cancer screening: performances of immunochemical colorectal cancer screening.

    PubMed

    Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy

    2010-01-01

    Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.

  5. Cervical cancer screening programs in Latin America and the Caribbean.

    PubMed

    Murillo, Raul; Almonte, Maribel; Pereira, Ana; Ferrer, Elena; Gamboa, Oscar A; Jerónimo, José; Lazcano-Ponce, Eduardo

    2008-08-19

    Latin America and the Caribbean (LAC) have a significant burden of cervical cancer. Prophylactic human papillomavirus (HPV) vaccines are an opportunity for primary prevention and new screening methods, such as new HPV DNA testing, are promising alternatives to cytology screening that should be analyzed in the context of regional preventive programs. Cytology-based screening programs have not fulfilled their expectations and coverage does not sufficiently explain the lack of impact on screening in LAC. While improved evaluation of screening programs is necessary to increase the impact of screening on the reduction of incidence and mortality, other programmatic aspects will need to be addressed such as follow-up of positive tests and quality control. The implementation of new technologies might enhance screening performance and reduce mortality in the region. The characteristics, performance and impact of cervical cancer screening programs in LAC are reviewed in this article.

  6. Pilot Testing a New Short Screen for the Assessment of Older Women's PTSD Symptomatology

    ERIC Educational Resources Information Center

    Lagana, Luciana; Schuitevoerder, Sage

    2009-01-01

    It is difficult for busy health care providers to perform routine screening for older women's posttraumatic stress symptomatology. This difficulty is due, at least partially, to a paucity of instruments specifically tested on such a population. To address this issue, in this preliminary study we tested an abbreviated screen from the set of 20…

  7. Screening large-scale association study data: exploiting interactions using random forests.

    PubMed

    Lunetta, Kathryn L; Hayward, L Brooke; Segal, Jonathan; Van Eerdewegh, Paul

    2004-12-10

    Genome-wide association studies for complex diseases will produce genotypes on hundreds of thousands of single nucleotide polymorphisms (SNPs). A logical first approach to dealing with massive numbers of SNPs is to use some test to screen the SNPs, retaining only those that meet some criterion for further study. For example, SNPs can be ranked by p-value, and those with the lowest p-values retained. When SNPs have large interaction effects but small marginal effects in a population, they are unlikely to be retained when univariate tests are used for screening. However, model-based screens that pre-specify interactions are impractical for data sets with thousands of SNPs. Random forest analysis is an alternative method that produces a single measure of importance for each predictor variable that takes into account interactions among variables without requiring model specification. Interactions increase the importance for the individual interacting variables, making them more likely to be given high importance relative to other variables. We test the performance of random forests as a screening procedure to identify small numbers of risk-associated SNPs from among large numbers of unassociated SNPs using complex disease models with up to 32 loci, incorporating both genetic heterogeneity and multi-locus interaction. Keeping other factors constant, if risk SNPs interact, the random forest importance measure significantly outperforms the Fisher Exact test as a screening tool. As the number of interacting SNPs increases, the improvement in performance of random forest analysis relative to Fisher Exact test for screening also increases. Random forests perform similarly to the univariate Fisher Exact test as a screening tool when SNPs in the analysis do not interact. In the context of large-scale genetic association studies where unknown interactions exist among true risk-associated SNPs or SNPs and environmental covariates, screening SNPs using random forest analyses can significantly reduce the number of SNPs that need to be retained for further study compared to standard univariate screening methods.

  8. Benefits of computer screen-based simulation in learning cardiac arrest procedures.

    PubMed

    Bonnetain, Elodie; Boucheix, Jean-Michel; Hamet, Maël; Freysz, Marc

    2010-07-01

    What is the best way to train medical students early so that they acquire basic skills in cardiopulmonary resuscitation as effectively as possible? Studies have shown the benefits of high-fidelity patient simulators, but have also demonstrated their limits. New computer screen-based multimedia simulators have fewer constraints than high-fidelity patient simulators. In this area, as yet, there has been no research on the effectiveness of transfer of learning from a computer screen-based simulator to more realistic situations such as those encountered with high-fidelity patient simulators. We tested the benefits of learning cardiac arrest procedures using a multimedia computer screen-based simulator in 28 Year 2 medical students. Just before the end of the traditional resuscitation course, we compared two groups. An experiment group (EG) was first asked to learn to perform the appropriate procedures in a cardiac arrest scenario (CA1) in the computer screen-based learning environment and was then tested on a high-fidelity patient simulator in another cardiac arrest simulation (CA2). While the EG was learning to perform CA1 procedures in the computer screen-based learning environment, a control group (CG) actively continued to learn cardiac arrest procedures using practical exercises in a traditional class environment. Both groups were given the same amount of practice, exercises and trials. The CG was then also tested on the high-fidelity patient simulator for CA2, after which it was asked to perform CA1 using the computer screen-based simulator. Performances with both simulators were scored on a precise 23-point scale. On the test on a high-fidelity patient simulator, the EG trained with a multimedia computer screen-based simulator performed significantly better than the CG trained with traditional exercises and practice (16.21 versus 11.13 of 23 possible points, respectively; p<0.001). Computer screen-based simulation appears to be effective in preparing learners to use high-fidelity patient simulators, which present simulations that are closer to real-life situations.

  9. Population Screening for Colorectal Cancer Means Getting FIT: The Past, Present, and Future of Colorectal Cancer Screening Using the Fecal Immunochemical Test for Hemoglobin (FIT)

    PubMed Central

    Fraser, Callum G.; Halloran, Stephen P.; Young, Graeme P.

    2014-01-01

    Fecal immunochemical tests for hemoglobin (FIT) are changing the manner in which colorectal cancer (CRC) is screened. Although these tests are being performed worldwide, why is this test different from its predecessors? What evidence supports its adoption? How can this evidence best be used? This review addresses these questions and provides an understanding of FIT theory and practices to expedite international efforts to implement the use of FIT in CRC screening. PMID:24672652

  10. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.

  11. Association between physiological falls risk and physical performance tests among community-dwelling older adults.

    PubMed

    Singh, Devinder K A; Pillai, Sharmila G K; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman's rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=-0.33), and FRT (r=-0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments.

  12. Performance of Implementing Guideline Driven Cervical Cancer Screening Measures in an Inner City Hospital System

    PubMed Central

    Wieland, Daryl L.; Reimers, Laura L.; Wu, Eijean; Nathan, Lisa M.; Gruenberg, Tammy; Abadi, Maria; Einstein, Mark H.

    2013-01-01

    Objective In 2006, the American Society for Colposcopy and Cervical Pathology (ASCCP) updated evidence based guidelines recommending screening intervals for women with abnormal cervical cytology. In our low-income inner city population, we sought to improve performance by uniformly applying the guidelines to all patients. We report the prospective performance of a comprehensive tracking, evidence-based algorithmically driven call-back and appointment scheduling system for cervical cancer screening in a resource-limited inner city population. Materials and Methods Outreach efforts were formalized with algorithm-based protocols for triage to colposcopy, with universal adherence to evidence-based guidelines. During implementation from August 2006 through July 2008, we prospectively tracked performance using the electronic medical record with administrative and pathology reports to determine performance variables such as the total number of Pap tests, colposcopy visits, and the distribution of abnormal cytology and histology results, including all CIN 2,3 diagnoses. Results 86,257 gynecologic visits and 41,527 Pap tests were performed system-wide during this period of widespread and uniform implementation of standard cervical cancer screening guidelines. The number of Pap tests performed per month varied little. The incidence of CIN 1 significantly decreased from 117/171 (68.4%) the first tracked month to 52/95 (54.7%) the last tracked month (p=0.04). The monthly incidence rate of CIN 2,3, including incident cervical cancers did not change. The total number of colposcopy visits declined, resulting in a 50% decrease in costs related to colposcopy services and approximately a 12% decrease in costs related to excisional biopsies. Conclusions Adherence to cervical cancer screening guidelines reduced the number of unnecessary colposcopies without increasing numbers of potentially missed CIN 2,3 lesions, including cervical cancer. Uniform implementation of administrative-based performance initiatives for cervical cancer screening minimizes differences in provider practices and maximizes performance of screening while containing cervical cancer screening costs. PMID:21959573

  13. Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen.

    PubMed

    Bamford, J; Fortnum, H; Bristow, K; Smith, J; Vamvakas, G; Davies, L; Taylor, R; Watkin, P; Fonseca, S; Davis, A; Hind, S

    2007-08-01

    To describe and analyse in detail current practice of school entry hearing screening (SES) in the UK. Main electronic databases were searched up to May 2005. A national postal questionnaire survey was addressed to all leads for SES in the UK, considering current practice in terms of implementation, protocols, target population and performance data. Primary data from cohort studies in one area of London were examined. A systematic review of alternative SES tests, test performance and impact on outcomes was carried out. Finally, a review of published studies on costs, plus economic modelling of current and alternative programmes was prepared. The survey suggested that SES is used in most of England, Wales and Scotland; just over 10% of respondents have abandoned the screen; others are awaiting national guidance. Coverage of SES is variable, but is often over 90% for children in state schools. Referral rates are variable, with a median of about 8%. The test used for the screen is the pure tone sweep test but with wide variation in implementation, with differing frequencies, pass criteria and retest protocols; written examples of protocols were often poor and ambiguous. There is no national approach to data collection, audit and quality assurance, and there are variable approaches at local level. The screen is performed in less than ideal test conditions and resources are often limited, which has an impact on the quality of the screen. The primary cohort studies show that the prevalence of permanent childhood hearing loss continues to increase through infancy. Of the 3.47 in 1000 children with a permanent hearing loss at school screen age, 1.89 in 1000 required identification after the newborn screen. Newborn hearing screening is likely to reduce significantly the yield of SES for permanent bilateral and unilateral hearing impairments; yield had fallen from about 1.11 in 1000 before newborn screening to about 0.34 in 1000 for cohorts that had had newborn screening, of which only 0.07 in 1000 were unilateral impairments. Just under 20% of permanent moderate or greater bilateral, mild bilateral and unilateral impairments, known to services as 6-year-olds or older, remained to be identified around the time of school entry. No good-quality published comparative trials of alternative screens or tests for SES were identified and studies concerned with the relative accuracy of alternative tests are difficult to compare and often flawed by differing referral criteria and case definitions; with full pure tone audiometry as the reference test, the pure tone sweep test appears to have high sensitivity and high specificity for minimal, mild and greater hearing impairments, better than alternative tests for which evidence was identified. There is insufficient evidence regarding possible harm of the screen. There were no published studies identified that examined the possible effects of SES on longer term outcomes. No good-quality published economic evaluations of SES were identified and a universal SES based on pure tone sweep tests was associated with higher costs and slightly higher quality-adjusted life-years (QALYs) compared with no screen and other screen alternatives; the incremental cost-effectiveness ratio for such a screen is around 2500 pounds per QALY gained; the range of expected costs, QALYs and net benefits was broad, indicating a considerable degree of uncertainty. Targeted screening could be more cost-effective than universal school entry screening; however, the lack of primary data and the wide limits for variables in the modelling mean that any conclusions must be considered indicative and exploratory only. A national screening programme for permanent hearing impairment at school entry meets all but three of the criteria for a screening programme, but at least six criteria are not met for screening for temporary hearing impairment. The lack of good-quality evidence in this area remains a serious problem. Services should improve quality and audit screen performance for identification of previously unknown permanent hearing impairment, pending evidence-based policy decisions based on the research recommendations. Further research is needed into a number of important areas including the evaluation of an agreed national protocol for services delivering SES to make future studies and audits of screen performance more directly comparable.

  14. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  15. Systematic review of colorectal cancer screening guidelines for average-risk adults: Summarizing the current global recommendations.

    PubMed

    Bénard, Florence; Barkun, Alan N; Martel, Myriam; von Renteln, Daniel

    2018-01-07

    To summarize and compare worldwide colorectal cancer (CRC) screening recommendations in order to identify similarities and disparities. A systematic literature search was performed using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge identifying all average-risk CRC screening guideline publications within the last ten years and/or position statements published in the last 2 years. In addition, a hand-search of the webpages of National Gastroenterology Society websites, the National Guideline Clearinghouse, the BMJ Clinical Evidence website, Google and Google Scholar was performed. Fifteen guidelines were identified. Six guidelines were published in North America, four in Europe, four in Asia and one from the World Gastroenterology Organization. The majority of guidelines recommend screening average-risk individuals between ages 50 and 75 using colonoscopy (every 10 years), or flexible sigmoidoscopy (FS, every 5 years) or fecal occult blood test (FOBT, mainly the Fecal Immunochemical Test, annually or biennially). Disparities throughout the different guidelines are found relating to the use of colonoscopy, rank order between test, screening intervals and optimal age ranges for screening. Average risk individuals between 50 and 75 years should undergo CRC screening. Recommendations for optimal surveillance intervals, preferred tests/test cascade as well as the optimal timing when to start and stop screening differ regionally and should be considered for clinical decision making. Furthermore, local resource availability and patient preferences are important to increase CRC screening uptake, as any screening is better than none.

  16. Performance Gains of Propellant Management Devices for Liquid Hydrogen Depots

    NASA Technical Reports Server (NTRS)

    Hartwig, Jason W.; McQuillen, John B.; Chato, David J.

    2013-01-01

    This paper presents background, experimental design, and preliminary experimental results for the liquid hydrogen bubble point tests conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to investigate the parameters that affect liquid acquisition device (LAD) performance in a liquid hydrogen (LH2) propellant tank, to mitigate risk in the final design of the LAD for the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, and to provide insight into optimal LAD operation for future LH2 depots. Preliminary test results show an increase in performance and screen retention over the low reference LH2 bubble point value for a 325 2300 screen in three separate ways, thus improving fundamental LH2 LAD performance. By using a finer mesh screen, operating at a colder liquid temperature, and pressurizing with a noncondensible pressurant gas, a significant increase in margin is achieved in bubble point pressure for LH2 screen channel LADs.

  17. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    PubMed

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  18. Research on target information optics communications transmission characteristic and performance in multi-screens testing system

    NASA Astrophysics Data System (ADS)

    Li, Hanshan

    2016-04-01

    To enhance the stability and reliability of multi-screens testing system, this paper studies multi-screens target optical information transmission link properties and performance in long-distance, sets up the discrete multi-tone modulation transmission model based on geometric model of laser multi-screens testing system and visible light information communication principle; analyzes the electro-optic and photoelectric conversion function of sender and receiver in target optical information communication system; researches target information transmission performance and transfer function of the generalized visible-light communication channel; found optical information communication transmission link light intensity space distribution model and distribution function; derives the SNR model of information transmission communication system. Through the calculation and experiment analysis, the results show that the transmission error rate increases with the increment of transmission rate in a certain channel modulation depth; when selecting the appropriate transmission rate, the bit error rate reach 0.01.

  19. Diagnostic performance of dual-staining cytology for cervical cancer screening: A systematic literature review.

    PubMed

    Tjalma, Wiebren A A

    2017-03-01

    Cervical cancer screening saves lives. Secondary prevention in cervical cancer screening relies on the results of primary cytology and/or HPV testing. However, primary screening with cytology has a low sensitivity, and HPV screening has a low specificity. This means that either cancers are missed, or women are over-treated. To improve performance outcomes, the concept of dual-stain cytology (CINtec ® PLUS Cytology test) has been introduced. In this approach, additional staining with p16/Ki-67 is performed in cases where cytology results are abnormal (LSIL or ASCUS) and/or HPV-positive. Another way to describe this approach might be "diagnostic" cytology. In order to assess the value of this "diagnostic cytology", a systematic literature review was conducted of dual-stain cytology performance across multiple studies until May 2016. In a Belgian screening population (women age 25-65 years), dual-stain cytology was significantly more sensitive (66%) and slightly less specific (-1.0%) than cytology. In the population referred to colposcopy or with abnormal cytology (ASCUS, LSIL), dual-staining showed a significantly higher increase in specificity, and a slightly lower sensitivity than HPV testing. Specificity gains resulted in fewer false positives and an increase in the number of correct referrals to colposcopy. Dual-staining with p16/Ki-67 cytology is an attractive biomarker approach for triage in cervical cancer screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Prevalence of Traditional and Reverse-Algorithm Syphilis Screening in Laboratory Practice: A Survey of Participants in the College of American Pathologists Syphilis Serology Proficiency Testing Program.

    PubMed

    Rhoads, Daniel D; Genzen, Jonathan R; Bashleben, Christine P; Faix, James D; Ansari, M Qasim

    2017-01-01

    -Syphilis serology screening in laboratory practice is evolving. Traditionally, the syphilis screening algorithm begins with a nontreponemal immunoassay, which is manually performed by a laboratory technologist. In contrast, the reverse algorithm begins with a treponemal immunoassay, which can be automated. The Centers for Disease Control and Prevention has recognized both approaches, but little is known about the current state of laboratory practice, which could impact test utilization and interpretation. -To assess the current state of laboratory practice for syphilis serologic screening. -In August 2015, a voluntary questionnaire was sent to the 2360 laboratories that subscribe to the College of American Pathologists syphilis serology proficiency survey. -Of the laboratories surveyed, 98% (2316 of 2360) returned the questionnaire, and about 83% (1911 of 2316) responded to at least some questions. Twenty-eight percent (378 of 1364) reported revision of their syphilis screening algorithm within the past 2 years, and 9% (170 of 1905) of laboratories anticipated changing their screening algorithm in the coming year. Sixty-three percent (1205 of 1911) reported using the traditional algorithm, 16% (304 of 1911) reported using the reverse algorithm, and 2.5% (47 of 1911) reported using both algorithms, whereas 9% (169 of 1911) reported not performing a reflex confirmation test. Of those performing the reverse algorithm, 74% (282 of 380) implemented a new testing platform when introducing the new algorithm. -The majority of laboratories still perform the traditional algorithm, but a significant minority have implemented the reverse-screening algorithm. Although the nontreponemal immunologic response typically wanes after cure and becomes undetectable, treponemal immunoassays typically remain positive for life, and it is important for laboratorians and clinicians to consider these assay differences when implementing, using, and interpreting serologic syphilis screening algorithms.

  1. Relationships Between Performance on Assessments of Executive Function and Fall Risk Screening Measures in Community-Dwelling Older Adults.

    PubMed

    Blackwood, Jennifer; Shubert, Tiffany; Forgarty, Kieran; Chase, Carla

    2016-01-01

    Fall-related injuries are a leading cause of institutionalization and morbidity in older adults. Limitations in cognition, including deficits in higher cognitive processes, like executive function (EF), contribute to a higher risk of falling in older adults. Specifically, declines in EF have been associated with changes in gait, limited mobility, and an increased frequency of falling. It is unknown whether associations between performance on commonly used clinical assessments of EF and performance on commonly used physical performance measures of fall risk are present. The purpose of this study was to examine the relationship between a clinical measure of EF, the Trail Making Test Part B (TMT-B), and 3 physical performance measures of fall risk: the Timed Up and Go (TUG) test, gait speed, and the Five Times Sit to Stand (FTSTS) test, in a group of community-dwelling older adults. Forty-seven community-dwelling older adults met the inclusion/exclusion criteria. Demographic information was obtained and measures of fall risk and cognition were performed. Correlations and linear regression analyses to assess relationships between measures were completed. To account for the high prevalence of mild cognitive impairment (MCI) in this population, the sample was screened and stratified for MCI in post hoc analyses. The EF performance was not significantly correlated with performance on the FTSTS test (ρ = 0.26, P > .05) but was significantly correlated with the TUG test (ρ = 0.31, P < .05) and gait speed (r = -0.36, P < .05). These relationships remained after adjusting for age and education in multivariate models. Results from post hoc analyses demonstrated that only those with MCI had significant relationships between EF and physical performance measures. TMT-B scores in the MCI group were significantly correlated with gait speed (ρ = -0.51, P < .05) and TUG test (ρ = 0.58, P < .05). A significant relationship exists between performance on clinical assessments of EF and fall risk assessments that integrate a mobility task for those individuals who screen positive for MCI. For those who screened negative, no significant relationship exists. Given the large prevalence of undiagnosed MCI in community-dwelling older adults, this finding could be used as an indication to screen older adults for MCI. Screening tools that require cognitive resources such as gait speed appear to have significant relationships with performance of EF for those who screen positive for MCI. This information could be used clinically to identify older adults with cognitive limitations, which could put them at higher risk for falling.

  2. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  3. Are overreferrals on developmental screening tests really a problem?

    PubMed

    Glascoe, F P

    2001-01-01

    Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.

  4. Cost effectiveness of fecal DNA screening for colorectal cancer: a systematic review and quality appraisal of the literature.

    PubMed

    Skally, Mairead; Hanly, Paul; Sharp, Linda

    2013-06-01

    Fecal DNA (fDNA) testing is a noninvasive potential alternative to current colorectal cancer screening tests. We conducted a systematic review and quality assessment of studies of cost-effectiveness of fDNA as a colorectal cancer screening tool (compared with no screening and other screening modalities), and identified key variables that impinged on cost-effectiveness. We searched MEDLINE, Embase, and the Centre for Reviews and Dissemination for cost-effectiveness studies of fDNA-based screening, published in English by September 2011. Studies that undertook an economic evaluation of fDNA, using either a cost-effectiveness or cost-utility analysis, compared with other relevant screening modalities and/or no screening were included. Additional inclusion criteria related to the presentation of data pertaining to model variables including time horizon, costs, fDNA performance characteristics, screening uptake, and comparators. A total of 369 articles were initially identified for review. After removing duplicates and applying inclusion and exclusion criteria, seven articles were included in the final review. Data was abstracted on key descriptor variables including screening scenarios, time horizon, costs, test performance characteristics, screening uptake, comparators, and incremental cost-effectiveness ratios. Quality assessment was undertaken using a standard checklist for economic evaluations. Studies cited by cost-effectiveness articles as the source of data on fDNA test performance characteristics were also reviewed. Seven cost-effectiveness studies were included, from the USA (4), Canada (1), Israel (1), and Taiwan (1). Markov models (5), a partially observable Markov decision process model (1) and MISCAN and SimCRC (1) microsimulation models were used. All studies took a third-party payer perspective and one included, in addition, a societal perspective. Comparator screening tests, screening intervals, and specific fDNA tests varied between studies. fDNA sensitivity and specificity parameters were derived from 12 research studies and one meta-analysis. Outcomes assessed were life-years gained and quality-adjusted life-years gained. fDNA was cost-effective when compared with no screening in six studies. Compared with other screening modalities, fDNA was not considered cost-effective in any of the base-case analyses: in five studies it was dominated by all alternatives considered. Sensitivity analyses identified cost, compliance, and test parameters as key influential parameters. In general, poor presentation of "study design" and "data collection" details lowered the quality of included articles. Although the literature searches were designed for high sensitivity, the possibility cannot be excluded that some eligible studies may have been missed. Reports (such as Health Technology Assessments produced by government agencies) and other forms of grey literature were excluded because they are difficult to identify systematically and/or may not report methods and results in sufficient detail for assessment. On the basis of the available (albeit limited) evidence, while fDNA is cost-effective when compared with no screening, it is currently dominated by most of the other available screening options. Cost and test performance appear to be the main influences on cost-effectiveness.

  5. Rural physicians' perspectives on cervical and breast cancer screening: a gender-based analysis.

    PubMed

    Ahmad, F; Stewart, D E; Cameron, J I; Hyman, I

    2001-03-01

    Several studies highlight the role of physicians in determining cervical and breast cancer screening rates, and some urban studies report higher screening rates by female physicians. Rural women in North America remain underscreened for breast and cervical cancers. This survey was conducted to determine if there were significant gender differences in practices and perceptions of barriers to breast and cervical cancer screening among rural family physicians in Ontario, Canada. One hundred ninety-one family physicians (response rate 53.1%) who practiced in rural areas, small towns, or small cities completed a mail questionnaire. The physicians' mean age was 44.4 years (SD 9.9), and mean number of years in practice was 16.6 years (SD 10.3). Over 90% of physicians reported that they were very likely to conduct a Pap test and clinical breast examination (CBE) during a periodic health examination, and they had high levels of confidence and comfort in performing these procedures. Male (68%) and female (32%) physicians were similar in their likelihood to conduct screening, levels of confidence and comfort, and knowledge of breast and cervical cancer screening guidelines. However, the self-reported screening rates for Pap tests and CBE performed during last year were higher for female than male physicians (p < 0.01). Male physicians reported they were asked more frequently by patients for a referral to another physician to perform Pap tests and CBE (p < 0.001). Also, male physicians perceived patients' embarrassment as a stronger barrier to performing Pap tests (p < 0.05) and CBE (p < 0.01) than female physicians. No gender differences were observed in screening rates or related barriers to mammography referrals. These findings suggest that physicians' gender plays a role in sex-sensitive examination, such as Pap tests and CBE. There is a need to facilitate physician-patient interactions for sex-sensitive cancer screening examinations by health education initiatives targeting male physicians and women themselves. The feasibility of providing sex-sensitive cancer screening examinations by a same-sex health provider should also be explored.

  6. Tuberculin reactivity in bacille Calmette-Guérin vaccinated populations: a compilation of international data.

    PubMed

    Joos, T J; Miller, W C; Murdoch, D M

    2006-08-01

    The effect of previously administered bacille Calmette-Guérin (BCG) vaccine on subsequent tuberculin skin tests (TSTs) complicates screening for latent tuberculosis infection (LTBI) in foreign-born persons. To determine the usefulness of the TST as a screening test for LTBI in foreign-born persons. A literature search was performed of published studies that compared tuberculin reactivity amongst BCG-vaccinated and non-vaccinated groups. The percentages of positive reactors in the two groups were then used to calculate a prevalence ratio. The prevalence ratio varied with the age of the groups tested and the incidence of TB in their countries of origin. The TST performed poorly in vaccinated persons of all ages from countries of low TB incidence, but was a useful screen for LTBI in vaccinated adults from countries of high and intermediate incidence. The test performed poorly as a screening method for vaccinated children under 2 years of age. Its usefulness in vaccinated children aged 2-14 years varied considerably. The usefulness of the TST as a screening method for LTBI depends on the age of the patient and the incidence of TB in their country of origin.

  7. Pre- and post-testing counseling considerations for the provision of expanded carrier screening: exploration of European geneticists' views.

    PubMed

    Janssens, Sandra; Chokoshvili, Davit; Vears, Danya F; De Paepe, Anne; Borry, Pascal

    2017-08-01

    Carrier screening is generally performed with the aim of identifying healthy couples at risk of having a child affected with a monogenic disorder to provide them with reproductive options. Expanded carrier screening (ECS), which provides the opportunity for multiple conditions to be screened in one test, offers a more cost-effective and comprehensive option than screening for single disorders. However, implementation of ECS at a population level would have implications for genetic counseling practice. We conducted semi-structured interviews with sixteen European clinical and molecular geneticists with expertise in carrier screening to explore their views on the implementation of ECS in the clinical setting. Using inductive content analysis, we identified content categories relevant to the pre- and post-test settings. Participants believed ECS would ideally be targeted at couples before pregnancy. There was some disagreement regarding the acceptability of performing ECS in individuals, with several participants actively opposing individual-based screening. In addition, participants discussed the importance of ensuring informed and voluntary participation in ECS, recommending measures to minimize external pressure on prospective parents to undergo testing. A need for adequate counseling to foster informed, autonomous reproductive decision-making and provide support for couples found to be at risk was emphasized. Practical challenges in optimizing pre-test education and post-test counseling should not be underestimated and they should be carefully addressed before implementing ECS in the clinical setting.

  8. Controversies in colorectal cancer screening.

    PubMed

    Pox, Christian P

    2014-01-01

    Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.

  9. Performance of a quantitative fecal immunochemical test in a colorectal cancer screening pilot program: a prospective cohort study.

    PubMed

    Telford, Jennifer; Gentile, Laura; Gondara, Lovedeep; McGahan, Colleen; Coldman, Andrew

    2016-01-01

    British Columbia undertook a colorectal cancer screening pilot program in 3 communities. Our objective was to assess the performance of 2-specimen fecal immunochemical testing in the detection of colorectal neoplasms in this population-based screening program. A prospective cohort of asymptomatic, average-risk people aged 50 to 74 years completed 2 quantitative fecal immunochemical tests every 2 years, with follow-up colonoscopy if the result of either test was positive. Participant demographics, fecal immunochemical test results, colonoscopy quality indicators and pathology results were recorded. Non-screen-detected colorectal cancer that developed in program participants was identified through review of data from the BC Cancer Registry. A total of 16 234 people completed a first round of fecal immunochemical testing, with a positivity rate of 8.6%; 5378 (86.0% of eligible participants) completed a second round before the end of the pilot program, with a positivity rate of 6.7%. Of the 1756 who had a positive test result, 1555 (88.6%) underwent colonoscopy. The detection rate of colorectal cancer was 3.5 per 1000 participants. The positive predictive value of the fecal immunochemical test was 4.9% (95% confidence interval [CI] 3.8%-6.0%) for colorectal cancer, 35.0% (95% CI 32.5%-37.2%) for high-risk polyps and 62.0% (95% CI 59.6%-64.4%) for all neoplasms. The number needed to screen was 283 to detect 1 cancer, 40 to detect 1 high-risk polyp and 22 to detect any neoplasm. Screening every 2 years with a 2-specimen fecal immunochemical test surpassed the current benchmark for colorectal cancer detection in population-based screening. This study has implications for other jurisdictions planning colorectal cancer screening programs.

  10. Screening and treating asymptomatic bacteriuria in pregnancy.

    PubMed

    Lumbiganon, Pisake; Laopaiboon, Malinee; Thinkhamrop, Jadsada

    2010-04-01

    Asymptomatic bacteriuria (ASB) in pregnancy, if left undiagnosed and appropriately treated can lead to acute pyelonephritis in mothers and low birth weight in infants. Urine culture is the gold standard for diagnosing ASB. Unfortunately, urine culture is limitedly available. The present review aims at evaluating performance of various screening tests and effectiveness of antibiotic regimens for ASB. Positive dipslide test is very likely to have a definitive diagnosis of ASB, whereas a negative result effectively rules out ASB. Available evidences regarding the performance of urine dipstick are still conflicting, it is currently not appropriate to recommend urine dipstick for screening ASB in pregnancy. Choice of antibiotics should be guided by antimicrobial susceptibility testing whenever possible. Nitrofurantoin seems to be antibiotic of choice for ASB in pregnancy. Seven-day regimen of antibiotics gives a better microbiological cure rate but no difference in important clinical outcomes compared with 1-day regimen. Dipslide culture is a promising screening test for ASB. Pregnant women with ASB should be treated with 7-day regimen of antibiotics, although 1-day regimen might be appropriate in some settings. More research is needed for identifying appropriate screening tests for ASB.

  11. Analyzing slug tests in wells screened across the watertable: A field assessment

    USGS Publications Warehouse

    Stanford, K.L.; McElwee, C.D.

    2000-01-01

    The slug test is the most widely used technique for the in situ estimation of hydraulic conductivity in confined and unconfined formations. Currently, there are no generally accepted methods in the groundwater literature for the analysis of response data from slug tests performed in wells screened across the watertable. A field study was undertaken in an attempt to develop a set of practical guidelines for tests conducted in such wells. Three wells, screened within unconsolidated material exhibiting a range of hydraulic conductivities (.05-30.0 m/day), were installed to depths of up to 9 m (30 ft) in Kansas River alluvium that ranges in thickness from 15 m to 21 m (50 ft to 70 ft) near Lawrence, Kansas. Intensive well-development efforts removed any drilling debris that could interfere with well-formation hydraulics. Once the wells were developed properly, a series of slug tests was performed at each well. The tests were designed to assess the role of the unsaturated zone and the appropriateness of assuming a fixed hydraulic head upper boundary. The results of this investigation can be summarized as follows: (1) the sufficiency of well development should be based on repeat slug tests and not the clarity of pumped water; (2) the effective screen radius for best model analysis should be based on a mass balance and not nominal screen dimensions; (3) the watertable can be represented as a constant head boundary and flow in the unsaturated zone can be ignored in most situations; (4) conventional techniques for the analysis of slug-test data seem to be reasonable for slug tests conducted in wells screened across the watertable, when used with the appropriate effective screen radius and normalized head range; and (5) fluctuations in the watertable elevation through time can be exploited to obtain some insight into the nature of vertical variation in hydraulic conductivity at a well. The results of this investigation indicate that multiple slug tests should be performed at wells screened across the watertable in order to reliably assess the sufficiency of well development and the appropriateness of conventional theory. ?? 2000 International Association for Mathematical Geology.

  12. [Human papillomavirus testing in cervical cancer screening at a public health service of Santiago, Chile].

    PubMed

    Terrazas, Solana; Ibáñez, Carolina; Lagos, Marcela; Poggi, Helena; Brañes, Jorge; Barriga, María Isabel; Cartagena, Jaime; Núñez, Felipe; González, Francisca; Cook, Paz; Van De Wyngard, Vanessa; Ferreccio, Catterina

    2015-01-01

    Molecular techniques for human papillomavirus (HPV) detection have a good performance as screening tests and could be included in cervical cancer early detection programs. We conducted a population-based trial comparing HPV detection and Papanicolaou as primary screening tests, in a public health service in Santiago, Chile. To describe the experience of implementing this new molecular test and present the main results of the study. Women aged 25 to 64 enrolled in three public health centers were invited to participate. In all women, samples were collected for Papanicolaou and HPV DNA testing, and naked-eye visual inspection of the cervix with acetic acid was performed. Women with any positive screening test were referred to the local area hospital for diagnostic confirmation with colposcopy and biopsy of suspicious lesions. Screening results were obtained for 8265 women, of whom 931 (11.3%) were positive to any test. The prevalence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was 1.1%; nine women had invasive cervical cancer. Sensitivities for the detection of CIN2+ were 22.1% (95% confidence interval (CI) 16.4-29.2) for Papanicolaou and 92.7% (95% CI 84.4-96.8) for HPV testing; specificities were 98.9% (95% CI 98.7-99.0) and 92.0% (95% CI 91.4-92.6) respectively. This experience showed that the implementation of a molecular test for cervical cancer screening is not a major challenge in Chile: it was well accepted by both the health team and the participants, and it may improve the effectiveness of the screening program.

  13. Steroid profiling for congenital adrenal hyperplasia by tandem mass spectrometry as a second-tier test reduces follow-up burdens in a tertiary care hospital: a retrospective and prospective evaluation.

    PubMed

    Seo, Ja Young; Park, Hyung-Doo; Kim, Jong Won; Oh, Hyeon Ju; Yang, Jeong Soo; Chang, Yun Sil; Park, Won Soon; Lee, Soo-Youn

    2014-01-01

    Newborn screening for congenital adrenal hyperplasia (CAH) based on measuring 17-hydroxyprogesterone (17-OHP) by immunoassay generates a number of false-positive results, especially in preterm neonates. We applied steroid profiling by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a second-tier test in newborns with positive CAH screening and evaluated its clinical utility in a tertiary care hospital setting. By performing a 4-year retrospective data review, we were able to test 121 dried blood spots from newborns with positive CAH screening for 17-OHP, androstenedione and cortisol levels by LC-MS/MS. We prospectively evaluated the clinical utility of steroid profiling after the implementation of steroid profiling as a second-tier test in our routine clinical practice. During the 2-year prospective study period, 104 cases with positive initial screening by FIA were tested by LC-MS/MS. Clinical and laboratory follow-up were performed for at least 6 months. The preterm neonates accounted for 50.7% (76/150) and 70.4% (88/125) of screening-positive cases in retrospective and prospective cohorts, respectively. By applying steroid profiling as a second-tier test for positive CAH screening, we eliminated all false-positive results and decreased the median follow-up time from 75 to 8 days. Our data showed that steroid profiling reduced the burden of follow-up exams by improving the positive predictive value of the CAH screening program. The use of steroid profiling as a second-tier test for positive CAH screening will improve clinical practice particularly in a tertiary care hospital setting where positive CAH screening from preterm neonates is frequently encountered.

  14. Stress-induced cortisol secretion impairs detection performance in x-ray baggage screening for hidden weapons by screening novices.

    PubMed

    Thomas, Livia; Schwaninger, Adrian; Heimgartner, Nadja; Hedinger, Patrik; Hofer, Franziska; Ehlert, Ulrike; Wirtz, Petra H

    2014-09-01

    Aviation security strongly depends on screeners' performance in the detection of threat objects in x-ray images of passenger bags. We examined for the first time the effects of stress and stress-induced cortisol increases on detection performance of hidden weapons in an x-ray baggage screening task. We randomly assigned 48 participants either to a stress or a nonstress group. The stress group was exposed to a standardized psychosocial stress test (TSST). Before and after stress/nonstress, participants had to detect threat objects in a computer-based object recognition test (X-ray ORT). We repeatedly measured salivary cortisol and X-ray ORT performance before and after stress/nonstress. Cortisol increases in reaction to psychosocial stress induction but not to nonstress independently impaired x-ray detection performance. Our results suggest that stress-induced cortisol increases at peak reactivity impair x-ray screening performance. Copyright © 2014 Society for Psychophysiological Research.

  15. Correlates of two experimental tests with performance in the FAA Academy air traffic control nonradar screen program.

    DOT National Transportation Integrated Search

    1990-08-01

    This study was designed to determine the relationships among experimental tests, the tests currently used to select entrants into the FAA's Air Traffic Control Specialist (ATCS) Academy Nonradar Screening Program, and Academy success. A battery of pa...

  16. Point-Counterpoint: Cervical Cancer Screening Should Be Done by Primary Human Papillomavirus Testing with Genotyping and Reflex Cytology for Women over the Age of 25 Years

    PubMed Central

    Zhao, Chengquan

    2015-01-01

    Screening for cervical cancer with cytology testing has been very effective in reducing cervical cancer in the United States. For decades, the approach was an annual Pap test. In 2000, the Hybrid Capture 2 human papillomavirus (HPV) test was approved by the U.S. Food and Drug Administration (FDA) for screening women who have atypical squamous cells of underdetermined significance (ASCUS) detected by Pap test to determine the need for colposcopy. In 2003, the FDA approved expanding the use of the test to include screening performed in conjunction with a Pap test for women over the age of 30 years, referred to as “cotesting.” Cotesting allows women to extend the testing interval to 3 years if both tests have negative results. In April of 2014, the FDA approved the use of an HPV test (the cobas HPV test) for primary cervical cancer screening for women over the age of 25 years, without the need for a concomitant Pap test. The approval recommended either colposcopy or a Pap test for patients with specific high-risk HPV types detected by the HPV test. This was based on the results of the ATHENA trial, which included more than 40,000 women. Reaction to this decision has been mixed. Supporters point to the fact that the primary-screening algorithm found more disease (cervical intraepithelial neoplasia 3 or worse [CIN3+]) and also found it earlier than did cytology or cotesting. Moreover, the positive predictive value and positive-likelihood ratio of the primary-screening algorithm were higher than those of cytology. Opponents of the decision prefer cotesting, as this approach detects more disease than the HPV test alone. In addition, the performance of this new algorithm has not been assessed in routine clinical use. Professional organizations will need to develop guidelines that incorporate this testing algorithm. In this Point-Counterpoint, Dr. Stoler explains why he favors the primary-screening algorithm, while Drs. Austin and Zhao explain why they prefer the cotesting approach to screening for cervical cancer. PMID:25948606

  17. Breast cancer screening in Italy: evaluating key performance indicators for time trends and activity volumes.

    PubMed

    Giordano, Livia; Castagno, Roberta; Giorgi, Daniela; Piccinelli, Cristiano; Ventura, Leonardo; Segnan, Nereo; Zappa, Marco

    2015-01-01

    Together with the National centre for screening monitoring (ONS), GISMa supports annual collection of data on national breast screening activities. Aggregated data on implementation and performance are gathered through a standardized form to calculate process and impact indicators. Analyzed data belong to 153 local programmes in the period 2006-2011 (2006-2012 for participation rate only). During the whole period, Italian crude participation rate exceeded GISMa's acceptable standard (50%), even though a higher participation in northern and central Italy compared to southern Italy and Islands was observed. Time trend analysis of diagnostic indicators confirmed in 2011 an adequate quality of breast screening performance, especially at subsequent screening. Recall rate at initial screening did not reach the acceptable standard (<7%) and rose slightly over the period. On the contrary, a good performance was achieved at subsequent screening. The same trend was followed by the overall detection rate and positive predictive value. They both showed a progressive reduction (from 6.2‰ in 2006 to 4.5‰ in 2011 for DR and from 8.0% in 2006 to 5.2% in 2011 for PPV, respectively) at initial screening and a good, stable trend at subsequent screening. Activity volume analysis shows that in programmes with greater activity (test/year ≥10,000) RR at both initial and subsequent screening has a better performance. This is also true for DR and PPV where programmes with high volumes of activity do better, especially when compared with those that interpret fewer than 5,000 mammograms per year. In spite of a few limits, these results are reassuring, and they reward the efforts made by screening professionals. It is therefore important to continue to monitor screening indicators and suggest, test, and evaluate new strategies for continuous improvement.

  18. Enhancing HIV Testing and Treatment among Men Who Have Sex with Men in China: A Pilot Model with Two-Rapid Tests, Single Blood Draw Session, and Intensified Case Management in Six Cities in 2013.

    PubMed

    Zhang, Dapeng; Lu, Hongyan; Zhuang, Minghua; Wu, Guohui; Yan, Hongjing; Xu, Jun; Wei, Xiaoli; Li, Chengmei; Meng, Sining; Fu, Xiaojing; Qi, Jinlei; Wang, Peng; Luo, Mei; Dai, Min; Yip, Ray; Sun, Jiangping; Wu, Zunyou

    2016-01-01

    To explore models to improve HIV testing, linkage to care and treatment among men who have sex with men (MSM) in cooperation with community-based organizations (CBOs) in China. We introduced a new model for HIV testing services targeting MSM in six cities in 2013.These models introduced provision of rapid HIV testing by CBO staff and streamlined processes for HIV screening, confirmation of initial reactive screening results, and linkage to care among diagnosed people. We monitored attrition along each step of the continuum of care from screening to treatment and compared program performance between 2012 and 2013. According to the providers of two rapid tests (HIV screening), four different services delivery models were examined in 2013: Model A = first screen at CDC, second at CDC (Model A = CDC+CDC), Model B = first and second screens at CBOs (Model B = CBO+CBO), Model C = first screen at CBO, second at Hospital (Model C = CBO+Hosp), and Model D = first screen at CBO, second at CDC (Model D = CBO+CDC). Logistic regressions were performed to assess advantages of different screening models of case finding and case management. Compared to 2012, the number of HIV screening tests performed for MSM increased 35.8% in 2013 (72,577 in 2013 vs. 53,455 in 2012). We observed a 5.6% increase in proportion of cases screened reactive receiving HIV confirmatory tests (93.9% in 2013 vs. 89.2% in 2012, χ2 = 48.52, p<0.001) and 65% reduction in loss to CD4 cell count tests (15% in 2013 vs. 43% in 2012, χ2 = 628.85, p<0.001). Regarding linkage to care and treatment, the 2013 pilot showed that the Model D had the highest rate of loss between screening reactive and confirmatory test among the four models, with 18.1% fewer receiving a second screening test and a further 5.9% loss among those receiving HIV confirmatory tests. The Model B and the Model C showed lower losses (0.8% and 1.3%) for newly diagnosed HIV positives receiving CD4 cell count tests, and higher rates of HIV positives referred to designated ART hospitals (88.0% and 93.3%) than the Model A and Model D (4.6% and 5.7% for CD4 cell count test, and 68.9% and 64.4% for referring to designated ART hospitals). The proportion of cases where the screening test was reactive that were commenced on ART was highest in Model C; 52.8% of cases commenced on ART compared to 38.9%, 34.2% and 21.1% in Models A, B and D respectively. Using Model A as a reference group, the multivariate logistic regression results also showed the advantages of Models B, C and D, which increased CD4 cell count test, referral to designated ART hospitals and initiation of ART, when controlling for program city and other factors. This study has demonstrated that involvement of CBOs in HIV rapid testing provision, streamlining testing and care procedures and early hospital case management can improve testing, linkage to, and retention in care and treatment among MSM in China.

  19. Test performance of immunologic fecal occult blood testing and sigmoidoscopy compared with primary colonoscopy screening for colorectal advanced adenomas.

    PubMed

    Khalid-de Bakker, Carolina A J; Jonkers, Daisy M A E; Sanduleanu, Silvia; de Bruïne, Adriaan P; Meijer, Gerrit A; Janssen, Jan B M J; van Engeland, Manon; Stockbrügger, Reinhold W; Masclee, Ad A M

    2011-10-01

    Given the current increase in colorectal cancer screening, information on performance of screening tests is needed, especially in groups with a presumed lower test performance. We compared test performance of immunologic fecal occult blood testing (FIT) and pseudosigmoidoscopy with colonoscopy for detection of advanced adenomas in an average risk screening population. In addition, we explored the influence of gender, age, and location on test performance. FIT was collected prior to colonoscopy with a 50 ng/mL cutoff point. FIT results and complete colonoscopy findings were available from 329 subjects (mean age: 54.6 ± 3.7 years, 58.4% women). Advanced adenomas were detected in 38 (11.6%) of 329 subjects. Sensitivity for advanced adenomas of FIT and sigmoidoscopy were 15.8% (95% CI: 6.0-31.3) and 73.7% (95% CI: 56.9-86.6), respectively. No sensitivity improvement was obtained using the combination of sigmoidoscopy and FIT. Mean fecal hemoglobin in FIT positives was significantly lower for participants with only proximal adenomas versus those with distal ones (P = 0.008), for women versus men (P = 0.023), and for younger (<55 years) versus older (≥55 years) subjects (P = 0.029). Sensitivities of FIT were 0.0% (95% CI: 0.0-30.9) in subjects with only proximal versus 21.4% (95% CI: 8.3-41.0) in those with distal nonadvanced adenomas; 5.3% (95% CI: 0.0-26.0) in women versus 26.3% (95% CI: 9.2-51.2) in men; 9.5% (95% CI: 1.2-30.4) in younger versus 23.5% (95% CI: 6.8-49.9) in older subjects. Sigmoidoscopy had a significantly higher sensitivity for advanced adenomas than FIT. A single FIT showed very low sensitivity, especially in subjects with only proximal nonadvanced adenomas, in women, and in younger subjects. This points to the existence of "low" FIT performance in subgroups and the need for more tailored screening strategies.

  20. Is HPV DNA testing specificity comparable to that of cytological testing in primary cervical cancer screening? Results of a meta-analysis of randomized controlled trials.

    PubMed

    Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria

    2014-07-01

    Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years. © 2013 UICC.

  1. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  2. Validation of a school-based amblyopia screening protocol in a kindergarten population.

    PubMed

    Casas-Llera, Pilar; Ortega, Paula; Rubio, Inmaculada; Santos, Verónica; Prieto, María J; Alio, Jorge L

    2016-08-04

    To validate a school-based amblyopia screening program model by comparing its outcomes to those of a state-of-the-art conventional ophthalmic clinic examination in a kindergarten population of children between the ages of 4 and 5 years. An amblyopia screening protocol, which consisted of visual acuity measurement using Lea charts, ocular alignment test, ocular motility assessment, and stereoacuity with TNO random-dot test, was performed at school in a pediatric 4- to 5-year-old population by qualified healthcare professionals. The outcomes were validated in a selected group by a conventional ophthalmologic examination performed in a fully equipped ophthalmologic center. The ophthalmologic evaluation was used to confirm whether or not children were correctly classified by the screening protocol. The sensitivity and specificity of the test model to detect amblyopia were established. A total of 18,587 4- to 5-year-old children were subjected to the amblyopia screening program during the 2010-2011 school year. A population of 100 children were selected for the ophthalmologic validation screening. A sensitivity of 89.3%, specificity of 93.1%, positive predictive value of 83.3%, negative predictive value of 95.7%, positive likelihood ratio of 12.86, and negative likelihood ratio of 0.12 was obtained for the amblyopia screening validation model. The amblyopia screening protocol model tested in this investigation shows high sensitivity and specificity in detecting high-risk cases of amblyopia compared to the standard ophthalmologic examination. This screening program may be highly relevant for amblyopia screening at schools.

  3. Vision Screening

    MedlinePlus

    ... testing when performed at a doctor's office. Corneal light reflex testing This simple test can be performed ... focuses on a penlight, the position of the light reflection from the front surface (cornea) of the ...

  4. Association between physiological falls risk and physical performance tests among community-dwelling older adults

    PubMed Central

    Singh, Devinder KA; Pillai, Sharmila GK; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Background Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. Methods One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman’s rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Results Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=−0.33), and FRT (r=−0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). Conclusion The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments. PMID:26316727

  5. Procedures for central auditory processing screening in schoolchildren.

    PubMed

    Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella

    2018-03-22

    Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that allow the selection of as many hearing skills as possible, validated by comparison with the battery of tests used in the diagnosis. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  6. Antenatal screening for Down syndrome using serum placental growth factor with the combined, quadruple, serum integrated and integrated tests.

    PubMed

    Wald, Nicholas J; Bestwick, Jonathan P; George, Lynne M; Huttly, Wayne J

    2012-01-01

    To estimate the value of first or second trimester placental growth factor (PlGF) as an additional antenatal screening marker for Down syndrome. Nested case-control study. Antenatal screening service. 532 Down syndrome pregnancies and 1,155 matched unaffected pregnancies. Stored maternal serum samples (-40°C) were assayed for PlGF. Monte Carlo simulation was used to estimate the screening performance of PlGF with the Combined, Quadruple, serum Integrated and Integrated tests. Median PlGF levels in affected and unaffected pregnancies and screening performance (detection rates [DR] for specified false-positive rates [FPR] and vice versa). First trimester median PlGF was 15%, 28% and 39% lower in Down syndrome than unaffected pregnancies at 11, 12 and 13 completed weeks' gestation respectively (all p<0.001). Second trimester median PlGF was 31% lower at 14 weeks (p<0.001), and the difference decreased (6% lower at 17 weeks). At a 90% DR with first trimester markers measured at 13 weeks, adding PlGF decreased the FPR from 11.1 to 5.1% using the Combined test, 9.3% to 4.5% using the serum Integrated test, and 3.4% to 1.5% using the Integrated test (or 1.5 to 1.4% with first trimester markers measured at 11 weeks). Adding PlGF to the Quadruple test (measured at 15 weeks) decreased the FPR from 10.0% to 9.6% at a 90% DR. First trimester PlGF measurements improve the performance of antenatal screening for Down syndrome using the Combined, serum Integrated and Integrated tests. Second trimester PlGF measurements are of limited value.

  7. Test set readings predict clinical performance to a limited extent: preliminary findings

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.

    2013-03-01

    Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.

  8. [Analysis of risk factors for dry eye syndrome in visual display terminal workers].

    PubMed

    Zhu, Yong; Yu, Wen-lan; Xu, Ming; Han, Lei; Cao, Wen-dong; Zhang, Hong-bing; Zhang, Heng-dong

    2013-08-01

    To analyze the risk factors for dry eye syndrome in visual display terminal (VDT) workers and to provide a scientific basis for protecting the eye health of VDT workers. Questionnaire survey, Schirmer I test, tear break-up time test, and workshop microenvironment evaluation were performed in 185 VDT workers. Multivariate logistic regression analysis was performed to determine the risk factors for dry eye syndrome in VDT workers after adjustment for confounding factors. In the logistic regression model, the regression coefficients of daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and female gender on the results of Schirmer I test were 0.153, 0.548, 0.400, 0.796, 0.234, 0.516, 0.559, and -0.685, respectively; the regression coefficients of daily mean time of exposure to screen, parallel screen-eye angle, upward screen-eye angle, age, working years, and female gender on tear break-up time were 0.021, 0.625, 2.652, 0.749, 0.403, and 1.481, respectively. Daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and working years are risk factors for dry eye syndrome in VDT workers.

  9. Predicting Math Outcomes from a Reading Screening Assessment in Grades 3-8. REL 2016-180

    ERIC Educational Resources Information Center

    Truckenmiller, Adrea J.; Petscher, Yaacov; Gaughan, Linda; Dwyer, Ted

    2016-01-01

    District and state education leaders frequently use screening assessments to identify students who are at risk of performing poorly on end-of-year achievement tests. This study examines the use of a universal screening assessment of reading skills for early identification of students at risk of low achievement on nationally normed tests of reading…

  10. Expanded Enlistment Eligibility Metrics (EEEM): Recommendations on a Non-Cognitive Screen for New Soldier Selection

    DTIC Science & Technology

    2010-07-01

    applicants and is pursing further research on the WPA. An operational test and evaluation ( IOT &E) has been initiated to evaluate the new screen...initial operational test and evaluation ( IOT &E) starting in fall 2009. vii EXPANDED ENLISTMENT ELIGIBILITY METRICS (EEEM): RECOMMENDATIONS ON A NON...Evaluation of a Performance Screen for IOT &E ..................................... 49 Approach

  11. Personal navigation increases colorectal cancer screening uptake.

    PubMed

    Ritvo, Paul G; Myers, Ronald E; Paszat, Lawrence F; Tinmouth, Jill M; McColeman, Joshua; Mitchell, Brian; Serenity, Mardie; Rabeneck, Linda

    2015-03-01

    Prior randomized, controlled trials (RCTs) indicate that patient navigation can boost colorectal cancer screening rates in primary care. The sparse literature on pragmatic trials of interventions designed to increase colorectal cancer screening adherence motivated this trial on the impact of a patient navigation intervention that included support for performance of the participants' preferred screening test (colonoscopy or stool blood testing). Primary care patients (n = 5,240), 50 to 74 years of age, with no prior diagnosis of bowel cancer and no record of a recent colorectal cancer screening test, were identified at the Group Health Centre in northern Ontario. These patients were randomly assigned to an intervention group (n = 2,629) or a usual care control group (n = 2,611). Intervention group participants were contacted by a trained nurse navigator by telephone to discuss colorectal cancer screening. Interested patients met with the navigator, who helped them identify and arrange for performance of the preferred screening test. Control group participants received usual care. Multivariate analyses were conducted using medical records data to assess intervention impact on screening adherence within 12 months after randomization. Mean patient age was 59 years, and 50% of participants were women. Colorectal cancer screening adherence was higher in the intervention group (35%) than in the control group (20%), a difference that was statistically significant (OR, 2.11; confidence interval, 1.87-2.39). Preference-based patient navigation increased screening uptake in a pragmatic RCT. Patient navigation increased colorectal cancer screening rates in a pragmatic RCT in proportions similar to those observed in explanatory RCTs. ©2014 American Association for Cancer Research.

  12. COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

    NASA Technical Reports Server (NTRS)

    Brusse, Jay A.; Sampson, Michael J.

    2004-01-01

    Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

  13. Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.

    PubMed

    Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N

    2007-05-01

    This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.

  14. Single Health System Adherence to 2012 Cervical Cancer Screening Guidelines at Extremes of Age and Posthysterectomy.

    PubMed

    Teoh, Deanna; Isaksson Vogel, Rachel; Hultman, Gretchen; Monu, Minnu; Downs, Levi; Geller, Melissa A; Le, Chap; Melton-Meaux, Genevieve; Kulasingam, Shalini

    2017-03-01

    To estimate the proportion of guideline nonadherent Pap tests in women aged younger than 21 years and older than 65 years and posthysterectomy in a single large health system. Secondary objectives were to describe temporal trends and patient and health care provider characteristics associated with screening in these groups. A retrospective cross-sectional chart review was performed at Fairview Health Services and University of Minnesota Physicians. Reasons for testing and patient and health care provider information were collected. Tests were designated as indicated or nonindicated per the 2012 cervical cancer screening guidelines. Point estimates and descriptive statistics were calculated. Patient and health care provider characteristics were compared between indicated and nonindicated groups using χ and Wilcoxon rank-sum tests. A total of 3,920 Pap tests were performed between September 9, 2012, and August 31, 2014. A total of 257 (51%; 95% confidence interval [CI] 46.1-54.9%) of tests in the younger than 21 years group, 536 (40%; 95% CI 37.7-43.1%) in the older than 65 years group, and 605 (29%; 95% CI 27.1-31.0%) in the posthysterectomy group were not indicated. White race in the older than 65 years group was the only patient characteristic associated with receipt of a nonindicated Pap test (P=.007). Health care provider characteristics associated with nonindicated Pap tests varied by screening group. Temporal trends showed a decrease in the proportion of nonindicated tests in the younger than 21 years group but an increase in the posthysterectomy group. For women aged younger than 21 years and older than 65 years and posthysterectomy, 35% of Pap tests performed in our health system were not guideline-adherent. There were no patient or health care provider characteristics associated with guideline nonadherent screening across all groups.

  15. Full Implementation of Screening for Nutritional Risk and Dysphagia in an Acute Stroke Unit: A Clinical Audit.

    PubMed

    Kampman, Margitta T; Eltoft, Agnethe; Karaliute, Migle; Børvik, Margrethe T; Nilssen, Hugo; Rasmussen, Ida; Johnsen, Stein H

    2015-10-01

    In patients with acute stroke, undernutrition and aspiration pneumonia are associated with increased mortality and length of hospital stay. Formal screening for nutritional risk and dysphagia helps to ensure optimal nutritional management in all patients with stroke and to reduce the risk of aspiration in patients with dysphagia. We developed a national guideline for nutritional and dysphagia screening in acute stroke, which was introduced in our stroke unit on June 1, 2012. The primary objective was to audit adherence to the guideline and to achieve full implementation. Second, we assessed the prevalence of nutritional risk and dysphagia. We performed a chart review to assess performance of screening for nutritional risk and dysphagia in all patients with stroke hospitalized for ≥48 hours between June 1, 2012, and May 31, 2013. Next we applied a "clinical microsystems approach" with rapid improvement cycles and audits over a 6-month period to achieve full implementation. The chart review showed that nutritional risk screening was performed in 65% and swallow testing in 91% of eligible patients (n = 185). Proactive implementation resulted in >95% patients screened (n = 79). The overall prevalence of nutritional risk was 29%, and 23% of the patients failed the initial swallow test. Proactive implementation is required to obtain high screening rates for nutritional risk and swallowing difficulties using validated screening tools. The proportion of patients at nutritional risk and the prevalence of dysphagia at initial swallow test were in the lower range of previous reports.

  16. [Analysis of tools, methods and results of toxicological screening for detection of drug abuse in Italian professional drivers].

    PubMed

    Rosso, G L

    2013-01-01

    Three years after a protocol agreement between the State and the Regions came into force in 2008 (drug testing at the workplace Law) a large number of studies have been conducted to analyse and test the efficacy of on-site screening tests for detection of drug consumption (opiates, cocaine, cannabinoids, amphetamine and methamphetamine, MDMA and methadone), which are frequently used by the occupational health physician, and also to present data resulting from workplace drug testing obtained during health surveillance programmes. The aim of the present study was to verify whether the features of sensitivity and specificity of the most common on-site testing ensure correct application of the provisions of current Italian legislation and also to analyse published studies showing the frequency of positive drug testing. A review of Italian and international literature was carried out aimed at identifying studies relating to: (1) performance of on-site screening tests frequently used by the occupational health physician, (2) prevalence of drug use/abuse among Italian public and commercial transport drivers. A comparison between the studies was then carried out. Several rapid on-site screening tests are commercially available (Italian law does not provide standards for the technical specifications of the tests), the sensitivity and specificity of which varies depending on the model and the substance tested. The sensitivity of these tools is poor when used for the detection of low concentrations of drugs and/or their metabolites in urine (close to the cut-off). Studies are lacking that compare on-site tests performed by the occupational health physician and confirmative tests in specialized laboratories (with particular regard to false positives found by the occupational health physician). The major studies in terms of methods and/or size reported a positive rate (confirmed at the first level) between 1.6% and 1.9%. The drugs most frequently used/abused were cannabis and cocaine. The performance of on-site screening tests (to detect psychotropic substances on urine matrix) and the methodology required by Italian law show that the aims of Italian workplace drug testing legislation have not been achieved The low positive rate observed in Italian studies could be due to an error in the first phase of screening performed by the occupational health physician.

  17. Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists.

    PubMed

    Torres-Mejía, Gabriela; Smith, Robert A; Carranza-Flores, María de la Luz; Bogart, Andy; Martínez-Matsushita, Louis; Miglioretti, Diana L; Kerlikowske, Karla; Ortega-Olvera, Carolina; Montemayor-Varela, Ernesto; Angeles-Llerenas, Angélica; Bautista-Arredondo, Sergio; Sánchez-González, Gilberto; Martínez-Montañez, Olga G; Uscanga-Sánchez, Santos R; Lazcano-Ponce, Eduardo; Hernández-Ávila, Mauricio

    2015-05-16

    An alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries. We evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed. Radiographer's sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7-86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7-57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6-0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms. Given the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists in countries with shortages of radiologists. Further studies are required to assess the effectiveness of different training programs in order to obtain acceptable screening accuracy, as well as the best approaches for the use of non-physician readers to interpret screening mammography.

  18. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  19. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  20. Performance of six diagnostic tests to screen for Chagas disease in blood banks andprevalence of Trypanosoma cruzi infection among donors with inconclusive serologyscreening based on the analysis of epidemiological variables.

    PubMed

    Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio

    2012-01-01

    The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.

  1. Clock Drawing as a Screen for Impaired Driving in Aging and Dementia: Is It Worth the Time?

    PubMed Central

    Manning, Kevin J.; Davis, Jennifer D.; Papandonatos, George D.; Ott, Brian R.

    2014-01-01

    Clock drawing is recommended by medical and transportation authorities as a screening test for unsafe drivers. The objective of the present study was to assess the usefulness of different clock drawing systems as screening measures of driving performance in 122 healthy and cognitively impaired older drivers. Clock drawing was measured using four different scoring systems. Driving outcomes included global ratings of safety and the error rate on a standardized on-road test. Findings revealed that clock drawing was significantly correlated with the driving score on the road test for each of the scoring systems. However, receiver operator curve analyses showed limited clinical utility for clock drawing as a screening instrument for impaired on-road driving performance with the area under the curve ranging from 0.53 to 0.61. Results from this study indicate that clock drawing has limited utility as a solitary screening measure of on-road driving, even when considering a variety of scoring approaches. PMID:24296110

  2. Clock drawing as a screen for impaired driving in aging and dementia: is it worth the time?

    PubMed

    Manning, Kevin J; Davis, Jennifer D; Papandonatos, George D; Ott, Brian R

    2014-02-01

    Clock drawing is recommended by medical and transportation authorities as a screening test for unsafe drivers. The objective of the present study was to assess the usefulness of different clock drawing systems as screening measures of driving performance in 122 healthy and cognitively impaired older drivers. Clock drawing was measured using four different scoring systems. Driving outcomes included global ratings of safety and the error rate on a standardized on-road test. Findings revealed that clock drawing was significantly correlated with the driving score on the road test for each of the scoring systems. However, receiver operator curve analyses showed limited clinical utility for clock drawing as a screening instrument for impaired on-road driving performance with the area under the curve ranging from 0.53 to 0.61. Results from this study indicate that clock drawing has limited utility as a solitary screening measure of on-road driving, even when considering a variety of scoring approaches.

  3. Medicare Cancer Screening in the Context of Clinical Guidelines: 2000 to 2012.

    PubMed

    Maroongroge, Sean; Yu, James B

    2018-04-01

    Cancer screening is a ubiquitous and controversial public health issue, particularly in the elderly population. Despite extensive evidence-based guidelines for screening, it is unclear how cancer screening has changed in the Medicare population over time. We characterize trends in cancer screening for the most common cancer types in the Medicare fee-for-service (FFS) program in the context of conflicting guidelines from 2000 to 2012. We performed a descriptive analysis of retrospective claims data from the Medicare FFS program based on billing codes. Our data include all claims for Medicare part B beneficiaries who received breast, colorectal (CRC), or prostate cancer screening from 2000 to 2012 based on billing codes. We utilize a Monte Carlo permutation method to detect changes in screening trends. In total, 231,416,732 screening tests were analyzed from 2000 to 2012, representing an average of 436.8 tests per 1000 beneficiaries per year. Mammography rates declined 7.4%, with digital mammography extensively replacing film. CRC cancer screening rates declined overall. As a percentage of all CRC screening tests, colonoscopy grew from 32% to 71%. Prostate screening rates increased 16% from 2000 to 2007, and then declined to 7% less than its 2000 rate by 2012. Both the aggressiveness of screening guidelines and screening rates for the Medicare FFS population peaked and then declined from 2000 to 2012. However, guideline publications did not consistently precede utilization trend shifts. Technology adoption, practical and financial concerns, and patient preferences may have also contributed to the observed trends. Further research should be performed on the impact of multiple, conflicting guidelines in cancer screening.

  4. Preliminary Report on a National Cross-Validation of the Computerized Adaptive Screening Test (CAST).

    ERIC Educational Resources Information Center

    Knapp, Deirdre J.; Pliske, Rebecca M.

    A study was conducted to validate the Army's Computerized Adaptive Screening Test (CAST), using data from 2,240 applicants from 60 army recruiting stations across the nation. CAST is a computer-assisted adaptive test used to predict performance on the Armed Forces Qualification Test (AFQT). AFQT scores are computed by adding four subtest scores of…

  5. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    PubMed

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  6. Relative Performance of HPV and Cytology Components of Cotesting in Cervical Screening.

    PubMed

    Schiffman, Mark; Kinney, Walter K; Cheung, Li C; Gage, Julia C; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas S; Wentzensen, Nicolas; Befano, Brian; Schussler, John; Katki, Hormuzd A; Castle, Philip E

    2018-05-01

    The main goal of cervical screening programs is to detect and treat precancer before cancer develops. Human papillomavirus (HPV) testing is more sensitive than cytology for detecting precancer. However, reports of rare HPV-negative, cytology-positive cancers are motivating continued use of both tests (cotesting) despite increased testing costs. We quantified the detection of cervical precancer and cancer by cotesting compared with HPV testing alone at Kaiser Permanente Northern California (KPNC), where 1 208 710 women age 30 years and older have undergone triennial cervical cotesting since 2003. Screening histories preceding cervical cancers (n = 623) and precancers (n = 5369) were examined to assess the relative contribution of the cytology and HPV test components in identifying cases. The performances of HPV testing and cytology were compared using contingency table methods, general estimating equation models, and nonparametric statistics; all statistical tests were two-sided. HPV testing identified more women subsequently diagnosed with cancer (P < .001) and precancer (P < .001) than cytology. HPV testing was statistically significantly more likely to be positive for cancer at any time point (P < .001), except within 12 months (P = .10). HPV-negative/cytology-positive results preceded only small fractions of cases of precancer (3.5%) and cancer (5.9%); these cancers were more likely to be regional or distant stage with squamous histopathology than other cases. Given the rarity of cancers among screened women, the contribution of cytology to screening translated to earlier detection of at most five cases per million women per year. Two-thirds (67.9%) of women found to have cancer during 10 years of follow-up at KPNC were detected by the first cotest performed. The added sensitivity of cotesting vs HPV alone for detection of treatable cancer affected extremely few women.

  7. Performance of alternative strategies for primary cervical cancer screening in sub-Saharan Africa: systematic review and meta-analysis of diagnostic test accuracy studies

    PubMed Central

    Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick

    2015-01-01

    Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020

  8. Red reflex screening in New Zealand: a large survey of practices and attitudes in the Auckland region.

    PubMed

    Raoof, Naz; Dai, Shuan

    2016-07-15

    Red reflex testing forms an essential part of newborn (within the first week of life) and infant (6 weeks of age) screening in New Zealand, as outlined in the Well Child/Tamariki Ora handbook. This survey of practitioners undertaking red reflex screening aimed to determine current practices and attitudes of screeners, as well as any barriers to screening. A short, multiple-choice, on-line questionnaire was sent to approximately 1,500 health care professionals undertaking red reflex screening, over a 4-week period. Four hundred and eighty-three survey responses were received from 267 GPs (55.4%), 153 midwives (31.7%), and 50 paediatricians (10.4%). Thirty-six respondents (7.8%) performed red reflex screening only when they had time to do so, 13 (2.8%) only undertook this when there were concerns raised by the parents. Most respondents (97.3%) used an ophthalmoscope to perform screening. Seventynine respondents (16.6%) felt they were "not sure/underconfident" at performing this test. Only 83 of 479 respondents (17.3%) had received any formal training. The development of an online resource or practical 'refresher' sessions would be well received and likely to improve current practices.

  9. HPV testing for cervical cancer screening appears more cost-effective than Papanicolau cytology in Mexico.

    PubMed

    Flores, Yvonne N; Bishai, David M; Lorincz, Attila; Shah, Keerti V; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge

    2011-02-01

    To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Screening women between the ages of 30-80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program.

  10. HPV testing for cervical cancer screening appears more cost-effective than Papanicolau cytology in Mexico

    PubMed Central

    Bishai, David M.; Lőrincz, Attila; Shah, Keerti V.; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge

    2010-01-01

    Objective To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. Methods A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Results Screening women between the ages of 30–80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. Conclusions This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program. PMID:21170578

  11. Application of Titration-Based Screening for the Rapid Pilot Testing of High-Throughput Assays.

    PubMed

    Zhang, Ji-Hu; Kang, Zhao B; Ardayfio, Ophelia; Ho, Pei-i; Smith, Thomas; Wallace, Iain; Bowes, Scott; Hill, W Adam; Auld, Douglas S

    2014-06-01

    Pilot testing of an assay intended for high-throughput screening (HTS) with small compound sets is a necessary but often time-consuming step in the validation of an assay protocol. When the initial testing concentration is less than optimal, this can involve iterative testing at different concentrations to further evaluate the pilot outcome, which can be even more time-consuming. Quantitative HTS (qHTS) enables flexible and rapid collection of assay performance statistics, hits at different concentrations, and concentration-response curves in a single experiment. Here we describe the qHTS process for pilot testing in which eight-point concentration-response curves are produced using an interplate asymmetric dilution protocol in which the first four concentrations are used to represent the range of typical HTS screening concentrations and the last four concentrations are added for robust curve fitting to determine potency/efficacy values. We also describe how these data can be analyzed to predict the frequency of false-positives, false-negatives, hit rates, and confirmation rates for the HTS process as a function of screening concentration. By taking into account the compound pharmacology, this pilot-testing paradigm enables rapid assessment of the assay performance and choosing the optimal concentration for the large-scale HTS in one experiment. © 2013 Society for Laboratory Automation and Screening.

  12. Determinants of Cervical Cancer Screening Accuracy for Visual Inspection with Acetic Acid (VIA) and Lugol’s Iodine (VILI) Performed by Nurse and Physician

    PubMed Central

    Raifu, Amidu O.; El-Zein, Mariam; Sangwa-Lugoma, Ghislain; Ramanakumar, Agnihotram; Walter, Stephen D.

    2017-01-01

    Background Visual inspection with acetic acid (VIA) and Lugol’s iodine (VILI) are used to screen women for cervical cancer in low-resource settings. Little is known about correlates of their diagnostic accuracy by healthcare provider. We examined determinants of VIA and VILI screening accuracy by examiner in a cross-sectional screening study of 1528 women aged 30 years or older in a suburb of Kinshasa, Democratic Republic of Congo. Methods We used a logistic regression model for sensitivity and specificity to estimate the diagnostic accuracy of VIA and VILI, independently performed by nurse and physician, as a function of sociodemographic and reproductive health characteristics. Results Nurses rated tests as positive more often than physicians (36.3% vs 30.2% for VIA, 26.2% vs 25.2% for VILI). Women’s age was the most important determinant of performance. It was inversely associated with sensitivity (nurse’s VIA: p<0.001, nurse’s VILI: p = 0.018, physician’s VIA: p = 0.005, physician’s VILI: p = 0.006) but positively associated with specificity (all four combinations: p<0.001). Increasing parity adversely affected sensitivity and specificity, but the effects on sensitivity were significant for nurses only. The screening performance of physician’s assessment was significantly better than the nurse’s (difference in sensitivity: VIA = 13%, VILI = 16%; difference in specificity: VIA = 6%, VILI = 1%). Conclusions Age and parity influence the performance of visual tests for cervical cancer screening. Proper training of local healthcare providers in the conduct of these tests should take into account these factors for improved performance of VIA and VILI in detecting cervical precancerous lesions among women in limited-resource settings. PMID:28107486

  13. Screening 5 and 6 year-old children starting primary school for development and language.

    PubMed

    Yılmaz, Deniz; Bayar-Muluk, Nuray; Bayoğlu, Birgül; İdil, Aysun; Anlar, Banu

    2016-01-01

    Beginning school is an important milestone for children. Children's readiness for school involves cognitive, physical, and emotional development. Certain school programs allow children to start first grade after 66 months of age, together with 72 month-old children. In order to estimate school readiness, we screened children before starting first grade and compared their school performance according to their age and socio-demographic characteristics. Marmara School Readiness, Denver II developmental screening, and language assessment tests were applied. Language delays were more frequent and school readiness test scores were lower in the younger group compared to older children. However, school achievement did not differ between the two age groups. Preschool education, parental income and education affected performance in most tests. Preschool screening seems effective in detecting children with lower than average developmental skills, and the school system may provide a practical opportunity for providing support to those children.

  14. [Screening for diabetes in France: data from the 2000-2001 cohort of the national medical insurance system].

    PubMed

    Hirtzlin, I; Fagot-Campagna, A; Girard-Le Gallo, I; Vallier, N; Poutignat, N; Weill, A; Le Laidier, S

    2004-04-01

    Type 2 diabetes mellitus may go undiagnosed for several Years while complications are silently developing. In France, from 2 to 3.7% of adults aged 35-65 are unaware they have diabetes. Nevertheless fasting serum glucose is a simple diagnostic test. We described people who underwent opportunist diabetes screening (serum glucose) within 2 Years (2000-2001). We used the administrative EPAS cohort from the employee National Health Insurance System which covers 70% of the total population in France. The data are based on reimbursements of glucose testing and hospitalization among people who did not received reimbursements of treatment for diabetes but used medical services during the 2 Years. The opportunistic screening rate within 2 Years was 48.6% overall and increased with age. Among those 45 Years old or older, it was 71.2%. The screening rate was higher among women than men. Opportunistic screening for diabetes is commonly practised in France, despite the lack of official guidelines. Several hypotheses may explain the discrepancy between common opportunist screening and high prevalence of undiagnosed diabetes: 1). undiagnosed diabetes is mostly present in people who do not use medical services; 2). opportunistic screening is not performed among the most at-risk population; 3). testing is not performed on fasting samples or results are neglected; 4). results of testing are overlooked by doctors/patients; 5). epidemiological studies based on self-report of diagnosis and only one testing overestimate undiagnosed diabetes.

  15. Asia Pacific consensus recommendations for colorectal cancer screening.

    PubMed

    Sung, J J Y; Lau, J Y W; Young, G P; Sano, Y; Chiu, H M; Byeon, J S; Yeoh, K G; Goh, K L; Sollano, J; Rerknimitr, R; Matsuda, T; Wu, K C; Ng, S; Leung, S Y; Makharia, G; Chong, V H; Ho, K Y; Brooks, D; Lieberman, D A; Chan, F K L

    2008-08-01

    Colorectal cancer (CRC) is rapidly increasing in Asia, but screening guidelines are lacking. Through reviewing the literature and regional data, and using the modified Delphi process, the Asia Pacific Working Group on Colorectal Cancer and international experts launch consensus recommendations aiming to improve the awareness of healthcare providers of the changing epidemiology and screening tests available. The incidence, anatomical distribution and mortality of CRC among Asian populations are not different compared with Western countries. There is a trend of proximal migration of colonic polyps. Flat or depressed lesions are not uncommon. Screening for CRC should be started at the age of 50 years. Male gender, smoking, obesity and family history are risk factors for colorectal neoplasia. Faecal occult blood test (FOBT, guaiac-based and immunochemical tests), flexible sigmoidoscopy and colonoscopy are recommended for CRC screening. Double-contrast barium enema and CT colonography are not preferred. In resource-limited countries, FOBT is the first choice for CRC screening. Polyps 5-9 mm in diameter should be removed endoscopically and, following a negative colonoscopy, a repeat examination should be performed in 10 years. Screening for CRC should be a national health priority in most Asian countries. Studies on barriers to CRC screening, education for the public and engagement of primary care physicians should be undertaken. There is no consensus on whether nurses should be trained to perform endoscopic procedures for screening of colorectal neoplasia.

  16. Fluorescent screens and image processing for the APS linac test stand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, W.; Ko, K.

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image processing will also be discussed.

  17. The clinical utility of HPV DNA testing in cervical cancer screening strategies.

    PubMed

    Bhatla, Neerja; Moda, Nidhi

    2009-09-01

    Cervical cancer continues to be the commonest cause of death among women in developing countries, largely due to the failure to the inability to sustain effective cytology-based screening programs. While this burden may come down following implementation of the human papillomavirus (HPV) vaccine, screening will still be required. HPV DNA testing is a promising new technology for cervical cancer prevention and is the most reproducible of all cervical cancer screening tests. Presently, the two assays most widely used for the detection of genital types are the polymerase chain reaction (PCR) and Hybrid Capture 2 assays (hc2). Rapid, affordable tests are expected to be available soon. HPV DNA testing can be used in a variety of clinical scenarios that include primary screening in women older than 30 yr; as an adjunctive test to cytology; in the triage of women with an equivocal cytologic report, e.g., ASC-US; or for follow-up post-treatment for cervical intraepithelial neoplasia (CIN). HPV DNA testing can also be performed on self-collected samples, which allows screening in remote areas and also in women who refuse gynecologic examination.

  18. Screening with Papanicolaou tests in Alberta

    PubMed Central

    Symonds, Christopher J.; Chen, Wenxin; Rose, Marianne Sarah; Cooke, Lara J.

    2018-01-01

    Abstract Objective To describe the prevalence and geographic distribution of cervical cancer screening, as well as the age groups of those undergoing screening, in Alberta, and to determine if screening practices conform to current guidelines and follow Choosing Wisely Canada recommendations. Design Descriptive study using data from the Alberta Ministry of Health Analytics and Performance Reporting Branch. Setting Alberta. Participants Women who had 1 or more Papanicolaou tests between 2011 and 2013. Main outcome measures Number of women aged 15 to 20 and those aged 70 and older who had 1 or more Pap tests in a 3-year period; year-to-year trends in screening rates for women in these 2 age groups; trends in screening rates in various geographic regions (ie, cities and zones) in Alberta; and the discipline of clinicians who ordered the Pap tests. Results Between 2011 and 2013, 805 632 women in the province of Alberta had 1 or more Pap tests for cervical cancer screening. Overall, 25 511 (17.5%) women aged 15 to 20 and 16 818 (10.3%) aged 70 and older were screened contrary to most existing guidelines. Screening rates varied markedly in different geographic regions of the province. Most Pap tests were ordered by family physicians or general practitioners. Conclusion Within the geographic regions of Alberta, provincial, national, and international guidelines for screening with Pap tests are inconsistently followed. This strongly echoes the need for clinicians and patients to consider the Choosing Wisely Canada recommendations and current guidelines for cervical cancer screening. PMID:29358254

  19. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    PubMed

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Prediction of success in FAA air traffic control field training as a function of selection and screening test performance.

    DOT National Transportation Integrated Search

    1989-05-01

    This study compared correlations between Office of Personnel Management (OPM) selection test scores for Air Traffic Control Specialists (ATCSs) and scores from the FAA Academy's second-stage screening program with measures of field training performan...

  1. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    DOT National Transportation Integrated Search

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  2. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    PubMed

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  3. Use of clinical movement screening tests to predict injury in sport

    PubMed Central

    Chimera, Nicole J; Warren, Meghan

    2016-01-01

    Clinical movement screening tests are gaining popularity as a means to determine injury risk and to implement training programs to prevent sport injury. While these screens are being used readily in the clinical field, it is only recently that some of these have started to gain attention from a research perspective. This limits applicability and poses questions to the validity, and in some cases the reliability, of the clinical movement tests as they relate to injury prediction, intervention, and prevention. This editorial will review the following clinical movement screening tests: Functional Movement Screen™, Star Excursion Balance Test, Y Balance Test, Drop Jump Screening Test, Landing Error Scoring System, and the Tuck Jump Analysis in regards to test administration, reliability, validity, factors that affect test performance, intervention programs, and usefulness for injury prediction. It is important to review the aforementioned factors for each of these clinical screening tests as this may help clinicians interpret the current body of literature. While each of these screening tests were developed by clinicians based on what appears to be clinical practice, this paper brings to light that this is a need for collaboration between clinicians and researchers to ensure validity of clinically meaningful tests so that they are used appropriately in future clinical practice. Further, this editorial may help to identify where the research is lacking and, thus, drive future research questions in regards to applicability and appropriateness of clinical movement screening tools. PMID:27114928

  4. Thermal Testing and Analysis of an Efficient High-Temperature Multi-Screen Internal Insulation

    NASA Technical Reports Server (NTRS)

    Weiland, Stefan; Handrick, Karin; Daryabeigi, Kamran

    2007-01-01

    Conventional multi-layer insulations exhibit excellent insulation performance but they are limited to the temperature range to which their components reflective foils and spacer materials are compatible. For high temperature applications, the internal multi-screen insulation IMI has been developed that utilizes unique ceramic material technology to produce reflective screens with high temperature stability. For analytical insulation sizing a parametric material model is developed that includes the main contributors for heat flow which are radiation and conduction. The adaptation of model-parameters based on effective steady-state thermal conductivity measurements performed at NASA Langley Research Center (LaRC) allows for extrapolation to arbitrary stack configurations and temperature ranges beyond the ones that were covered in the conductivity measurements. Experimental validation of the parametric material model was performed during the thermal qualification test of the X-38 Chin-panel, where test results and predictions showed a good agreement.

  5. Enhanced passive screening and diagnosis for gambiense human African trypanosomiasis in north-western Uganda – Moving towards elimination

    PubMed Central

    Bessell, Paul Richard; Ndung’u, Joseph Mathu

    2017-01-01

    Introduction The incidence of gambiense human African trypanosomiasis (gHAT) in Uganda has been declining, from 198 cases in 2008, to only 20 in 2012. Interruption of transmission of the disease by early diagnosis and treatment is core to the control and eventual elimination of gHAT. Until recently, the format of available screening tests had restricted screening and diagnosis to central health facilities (passive screening). We describe a novel strategy that is contributing to elimination of gHAT in Uganda through expansion of passive screening to the entire population at risk. Methodology / Principal findings In this strategy, patients who are clinically suspected of having gHAT at primary health facilities are screened using a rapid diagnostic test (RDT), followed by parasitological confirmation at strategically located microscopy centres. For patients who are positive with the RDT and negative by microscopy, blood samples undergo further testing using loop-mediated isothermal amplification (LAMP), a molecular test that detects parasite DNA. LAMP positive patients are considered strong suspects, and are re-evaluated by microscopy. Location and upgrading of facilities to perform microscopy and LAMP was informed by results of georeferencing and characterization of all public healthcare facilities in the 7 gHAT endemic districts in Uganda. Three facilities were upgraded to perform RDTs, microscopy and LAMP, 9 to perform RDTs and microscopy, and 200 to screen patients with RDTs. This reduced the distance that a sick person must travel to be screened for gHAT to a median distance of 2.5km compared to 23km previously. In this strategy, 9 gHAT cases were diagnosed in 2014, and 4 in 2015. Conclusions This enhanced passive screening strategy for gHAT has enabled full coverage of the population at risk, and is being replicated in other gHAT endemic countries. The improvement in case detection is making elimination of the disease in Uganda an imminent possibility. PMID:29023573

  6. Monothermal caloric screening test performance: a relative operating characteristic curve analysis.

    PubMed

    Murnane, Owen D; Akin, Faith W; Lynn, Susan G; Cyr, David G

    2009-06-01

    The objective of the present study was to evaluate the performance of the monothermal caloric screening test in a large sample of patients. A retrospective analysis of the medical records of 1002 consecutive patients who had undergone vestibular assessment at the Mayo Clinic during the years 1989 and 1990 was conducted. Patients with incomplete alternate binaural bithermal (ABB) caloric testing, congenital or periodic alternating nystagmus, or bilateral vestibular loss were excluded from the study. Clinical decision theory analyses (relative operating characteristic curves) were used to determine the accuracy with which the monothermal warm (MWST) and monothermal cool (MCST) caloric screening tests predicted the results of the ABB caloric test. Cumulative distributions were constructed as a function of the cutoff points for monothermal interear difference (IED) to select the cutoff point associated with any combination of true-positive and false-positive rates. Both MWST and MCST performed well above chance level. The test performance for the MWST was significantly better than that of the MCST for three of the four ABB gold standards. A 10% IED cutoff point for the MWST yielded a false-negative rate of either 1% (UW >or=25%) or 3% (UW >or=20%). The use of a 10% IED (UW >or=25%) for the MWST would have resulted in a 40% reduction (N = 294) in the number of ABB caloric tests performed on patients without a unilateral weakness. The results of this study indicated that the MWST decreases test time without sacrificing the sensitivity of the ABB caloric test.

  7. Single-visit approach of cervical cancer screening: See and Treat in Indonesia

    PubMed Central

    Vet, J N I; Kooijman, J L; Henderson, F C; Aziz, F M; Purwoto, G; Susanto, H; Surya, I G D; Budiningsih, S; Cornain, S; Fleuren, G J; Trimbos, J B; Peters, A A W

    2012-01-01

    Background: We performed a cross-sectional study in Indonesia to evaluate the performance of a single-visit approach of cervical cancer screening, using visual inspection with acetic acid (VIA), histology and cryotherapy in low-resource settings. Methods: Women having limited access to health-care facilities were screened by trained doctors using VIA. If the test was positive, biopsies were taken and when eligible, women were directly treated with cryotherapy. Follow-up was performed with VIA and cytology after 6 months. When cervical cancer was suspected or diagnosed, women were referred. The positivity rate, positive predictive value (PPV) and approximate specificity of the VIA test were calculated. The detection rate for cervical lesions was given. Results: Screening results were completed in 22 040 women, of whom 92.7% had never been screened. Visual inspection with acetic acid was positive in 4.4%. The PPV of VIA to detect CIN I or greater and CIN II or greater was 58.7% and 29.7%, respectively. The approximate specificity was 98.1%, and the detection rate for CIN I or greater was 2.6%. Conclusion: The single-visit approach cervical cancer screening performed well, showing See and Treat is a promising way to reduce cervical cancer in Indonesia. PMID:22850550

  8. Serological diagnosis of canine leishmaniosis: comparison of three commercial ELISA tests (Leiscan®, ID Screen® and Leishmania 96®), a rapid test (Speed Leish K®) and an in-house IFAT

    PubMed Central

    2014-01-01

    Background Speed Leish K® is used as a serological screening test for Leishmania infection prior to vaccination. Limited comparative serological studies with Speed Leish K® have been performed. The aim of this study was to evaluate the diagnostic performance of four commercially available serologic tests including ELISAs (Leiscan®, ID Screen® and Leishmania 96®), a rapid test (Speed Leish K®) and an in-house IFAT for the detection of specific antibodies against Leishmania infantum antigen in dogs in different states of infection. Methods Sick infected dogs (n = 36), healthy infected dogs (n = 18), L. infantum seropositive dogs with low to high levels of antibodies (n = 53), dogs seropositive to other pathogens (to evaluate cross reaction) (n = 14) and uninfected dogs from a non-endemic area (n = 50) and from an endemic area (n = 32) were analysed by the serological methods mentioned above. Results The sensitivity was as follows: ID Screen® (0.953), Leiscan® and Leishmania 96® (0.925), IFAT (0.869) and Speed Leish K® (0.636). The maximum specificity (1.000) was attained for all diagnostic tests except the Leishmania 96® (0.896) and IFAT (0.917). The accuracy was as follows: ID Screen® (0.975), Leiscan® (0.961), Leishmania 96® (0.911), IFAT (0.892) and Speed Leish K® (0.808). In relation to the area under the ROC curve (AUC-ROC), the maximum value was attained with the ID Screen® (0.993) closely followed by Leiscan® (0.990), then, Leishmania 96® (0.962), IFAT (0.926) and Speed Leish K® (0.818). For the Kappa index, the best result was obtained by the ID Screen® (0.951) followed by Leiscan® (0.921), Leishmania 96® (0.822), IFAT (0.783) and Speed Leish K® (0.622). Statistically significant differences were found between the AUC-ROC of quantitative serological tests and the only qualitative rapid test evaluated. There were also statistically significant differences between AUC-ROC of the ELISAs (ID Screen® and Leiscan®) and IFAT. Conclusions Leiscan® and ID Screen® had superior diagnostic performance measures than IFAT and all quantitative serological tests were superior when compared to Speed Leish K®. Thus, Speed Leish K® may be considered a less valuable screening test prior to vaccination as it may result in vaccination of seropositive dogs and in some cases seropositive sick dogs. PMID:24655335

  9. Effects of three pesticides on the avoidance behavior of earthworms in laboratory tests performed under temperate and tropical conditions.

    PubMed

    Garcia, Marcos; Römbke, Jörg; de Brito, Marcus Torres; Scheffczyk, Adam

    2008-05-01

    Little research has been performed on the impact of pesticides on earthworms under tropical conditions. Taking into consideration the often-limited resources in tropical countries, simple screening tests are needed. Therefore, it was investigated whether three pesticides relevant for the Brazilian Amazon (benomyl, carbendazim, lambda-cyhalothrin) affect the avoidance behavior of the earthworm Eisenia fetida. The tests were performed for two days according to ISO guideline 17512 but were adapted to tropical conditions (i.e. test substrate, test organism and temperature). The results indicate that this test gives reproducible and reliable results. Toxicity values (NOEC, EC50) are lower than those determined in 14 day-acute mortality tests and are approximately in the same range such as those found in 56 day-chronic reproduction tests with the same earthworm species, which were performed in parallel. Therefore, the use of the earthworm avoidance tests is recommended as a screening tool for the risk assessment of pesticides.

  10. Validity of screening tests for Sjögren's syndrome in ambulatory patients with chronic diseases.

    PubMed

    Sánchez-Guerrero, Jorge; Pérez-Dosal, Marcia R; Celis-Aguilar, Erika; Cárdenas-Velázquez, Francisco; Soto-Rojas, Armando E; Avila-Casado, Carmen

    2006-05-01

    To determine the validity of screening tests for Sjogren's syndrome (SS) in ambulatory patients with chronic diseases. Three hundred randomly selected patients from the rheumatology and internal medicine clinics of a tertiary care center were assessed for SS according to the American-European Consensus Group criteria. During the screening phase, an interview, the European questionnaire for sicca symptoms, Schirmer-I test, and the wafer test were carried out in all patients. Patients with positive screening had confirmatory tests including fluorescein staining test, nonstimulated whole salivary flow, and autoantibody testing. Confirmatory tests were also done in 13 patients with negative screening. During the last phase, lip biopsy was proposed to patients who met preestablished criteria. Women made up 79% of the study population. Mean age of subjects was 42.8+/-15.7 years. Two hundred twenty patients (73%) had positive screening. The distribution of positive test results was: xerophthalmia 118 (39%), xerostomia 103 (34%), Schirmer-I test 101 (34%), and wafer test 187 (62%) patients. Forty (13%) patients met criteria for SS. All screening tests were useful for identifying patients with SS; however, the model composed of at least one positive response to the European questionnaire (EQ1), Schirmer-I test, and wafer test showed the best performance. Use of the European questionnaire, Schirmer-I test, and wafer test in parallel was useful for identifying patients with SS among ambulatory patients with chronic diseases.

  11. Performance Evaluation Test of the Orbit Screen Model 68A and the Komplet Model 48-25 Rock Crusher

    DTIC Science & Technology

    2008-08-01

    two representatives from the Government of Ecuador, Ms . Viviana Anabela Meza Cevallos, from the Demining Center of Ecuador, and Lieutenant Jose Luis...Mines ( MRMs ) Antipersonnel Simulants............................ 8 4 Orbit Screen Model 68 Testing...Mock Mine .............................................................................................................. 7 Figure 8: MRM Simulant, Type

  12. Influences and Practices in Colorectal Cancer Screening Among Health Care Providers Serving Northern Plains American Indians, 2011-2012.

    PubMed

    Nadeau, Melanie; Walaszek, Anne; Perdue, David G; Rhodes, Kristine L; Haverkamp, Donald; Forster, Jean

    2016-12-15

    The epidemiology of colorectal cancer, including incidence, mortality, age of onset, stage of diagnosis, and screening, varies regionally among American Indians. The objective of the Improving Northern Plains American Indian Colorectal Cancer Screening study was to improve understanding of colorectal cancer screening among health care providers serving Northern Plains American Indians. Data were collected, in person, from a sample of 145 health care providers at 27 health clinics across the Northern Plains from May 2011 through September 2012. Participants completed a 32-question, self-administered assessment designed to assess provider practices, screening perceptions, and knowledge. The proportion of providers who ordered or performed at least 1 colorectal cancer screening test for an asymptomatic, average-risk patient in the previous month was 95.9% (139 of 145). Of these 139 providers, 97.1% ordered colonoscopies, 12.9% ordered flexible sigmoidoscopies, 73.4% ordered 3-card, guaiac-based, fecal occult blood tests, and 21.6% ordered fecal immunochemical tests. Nearly two-thirds (64.7%) reported performing in-office guaiac-based fecal occult blood tests using digital rectal examination specimens. Providers who reported receiving a formal update on colorectal cancer screening during the previous 24 months were more likely to screen using digital rectal exam specimens than providers who had received a formal update on colorectal cancer screening more than 24 months prior (73.9% vs 56.9%, respectively, χ 2 = 4.29, P = .04). Despite recommendations cautioning against the use of digital rectal examination specimens for colorectal cancer screening, the practice is common among providers serving Northern Plains American Indian populations. Accurate up-to-date, ongoing education for patients, the community, and health care providers is needed.

  13. Screening for prostate cancer: are digital rectal examinations being performed?

    PubMed

    Federman, Daniel G; Pitkin, Patricia; Carbone, Vera; Concato, John; Kravetz, Jeffrey D

    2014-04-01

    Prostate cancer is common and prostate cancer screening is controversial; this retrospective observational study was conducted to determine the prevalence of digital rectal examination (DRE) in those in whom a prostate-specific antigen (PSA) test was performed. A manual review was performed of the electronic medical record for male veterans in the VA Connecticut Healthcare System without a history of known prostate cancer aged between 50 and 74 years who underwent PSA testing. Documentation of DRE (or refusal) within 12 months before or after the performance of a PSA test. Less than half (47.6%) of patients underwent DRE. An additional 6.9% were offered DRE and refused. Although the provider gender was not associated with DRE, resident physicians were less likely to perform DRE than nonresidents; P = 0.01. Patients whose PSA was > 4.0 ng/mL were more likely to undergo DRE than those whose PSA was ≤ 4.0 ng/mL; P = 0.002. Those with body mass index (BMI) > 40 kg/m 2 were less likely to undergo DRE than those with BMI < 30 kg/m 2 ; P = 0.04. Screening for prostate cancer remains controversial. We found a low rate of DRE among veterans in whom prostate cancer screening was entertained. Although the provider gender does not seem to influence DRE, resident physicians were less likely to perform DRE than other providers. Our finding that BMI > 40 kg/m 2 is associated with a lower rate of DRE than those with BMI < 30 kg/m 2 is consistent with screening for other cancers and should be explored further.

  14. 49 CFR 1544.409 - Integrity of screener tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... screening location, TSA may authorize an employee of one or more of the aircraft operators or foreign air..., screener, screener-in-charge, checkpoint security supervisor, or other screening supervisor. The employee... AND COMMERCIAL OPERATORS Screener Qualifications When the Aircraft Operator Performs Screening § 1544...

  15. Bilingualism in older Mexican-American immigrants is associated with higher scores on cognitive screening.

    PubMed

    Padilla, Claudia; Mendez, Mario F; Jimenez, Elvira E; Teng, Edmond

    2016-11-24

    Bilingualism may protect against cognitive aging and delay the onset of dementia. However, studies comparing monolinguals and bilinguals on such metrics have produced inconsistent results complicated by confounding variables and methodological concerns. We addressed this issue by comparing cognitive performance in a more culturally homogeneous cohort of older Spanish-speaking monolingual (n = 289) and Spanish-English bilingual (n = 339) Mexican-American immigrants from the Sacramento Longitudinal Study on Aging. After adjusting for demographic differences and depressive symptoms, both groups performed similarly at baseline on verbal memory but the bilingual group performed significantly better than the monolingual group on a cognitive screening test, the Modified Mini-Mental State Examination (3MS; p < 0.001). Group differences on the 3MS were driven by language/executive and language/praxis factors. Within the bilingual group, neither language of testing nor degree of bilingualism was significantly associated with 3MS or verbal memory scores. Amongst individuals who performed in the normal or better range on both tests at baseline and were followed for an average of 6 years, both monolinguals and bilinguals exhibited similar rates of cognitive decline on both measures. These findings suggest that bilingualism is associated with modest benefits in cognitive screening performance in older individuals in cross-sectional analyses that persist across longitudinal analyses. The effects of bilingualism should be considered when cognitively screening is performed in aging immigrant populations.

  16. Notes on testing non-inferiority under the partial verification design with a confirmatory procedure limited to screen positives.

    PubMed

    Lui, Kung-Jong

    2012-05-01

    When a new test with fewer invasions or less expenses to administer than the traditional test is developed, we may be interested in testing whether the former is non-inferior to the latter with respect to test accuracy. We define non-inferiority via both the odds ratio (OR) of correctly identifying a case and the OR of correctly identifying a non-case between two tests under comparison. We focus our discussion on testing the non-inferiority of a new screening test to a traditional screening test when a confirmatory procedure is performed only on patients with screen positives. On the basis of well-established methods for paired-sample data, we derive an asymptotic test procedure and an exact test procedure with respect to the two ORs defined here. Using Monte Carlo simulation, we evaluate the performance of these test procedures in a variety of situations. We note that the test procedures proposed here can also be applicable if we are interested in testing non-inferiority with respect to the ratio of sensitivities and the ratio of specificities. We discuss interval estimation of these ORs and sample size calculation based on the asymptotic test procedure considered here. We use the data taken from a study of the prostate-specific-antigen (PSA) test and the digital rectal examination (DRE) test to illustrate the practical use of these test procedures, interval estimators and sample size calculation formula. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Providing detailed information about latent tuberculosis and compliance with the PPD test among healthcare workers in Israel: a randomized controlled study.

    PubMed

    Taubman, Danielle; Titler, Nava; Edelstein, Hana; Elias, Mazen; Saliba, Walid

    2013-12-01

    The compliance of screening for latent tuberculosis (TB) with the tuberculin purified protein derivative (PPD) test is very low among healthcare workers (HCWs) in Israel. This randomized controlled study uses the Health Belief Model (HBM) as a conceptual framework to examine whether providing more information about latent TB and the PPD test increases the response rate for PPD screening among HCWs. All candidate HCWs for latent TB screening were randomly allocated to one of the following two invitations to perform the PPD test: regular letter (control group, n=97), and a letter with information about latent TB and the PPD test (intervention group, n=196). 293 HCWs were included (185 nurses, and 108 physicians). Overall, 36 (12.3%) HCWs were compliant with the PPD test screening. Compliance with PPD testing in the intervention group was not statistically different from the control group, RR 0.87 (95% CI, 0.46-1.65). Compliance for latent TB screening is low among HCWs in northeastern Israel. Providing detailed information about latent TB was not associated with increased test compliance. Understanding existing disparities in screening rates and potential barriers to latent TB screening among HCWs is important in order to move forward and successfully increase screening rates. Copyright © 2013 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  18. Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB). Part 1: Design and specification of the battery

    NASA Astrophysics Data System (ADS)

    Englund, C. E.; Reeves, D. L.; Shingledecker, C. A.; Thorne, D. R.; Wilson, K. P.

    1987-02-01

    The Unified Tri-Service Cognitive Performance Assessment Battery (UTC-PAB) represents the primary metric for a Level 2 evaluation of cognitive performance in the JWGD3 MILPERF chemical defense biomedical drug screening program. Emphasis for UTC-PAB development has been on the standardization of test batteries across participating laboratories with respect to content, computer-based administration, test scoring, and data formatting. This effort has produced a 25-test UTC-PAB that represents the consolidation and unification of independent developments by the Tri-service membership. Test selection was based on established test validity and relevance of military performance. Sensitivity to effects of hostile environments and sustained operations were also considerations involved in test selection. Information processing, decision making, perception, and mental workload capacity are among the processes and abilities addressed in the battery. The UTC-PAB represents a dynamic approach to battery development. The nature of the biomedical drugs screened and information from performance centered task analyses will direct the form of future versions of the battery.

  19. Standing wave performance test of IDT-SAW transducer prepared by silk-screen printing

    NASA Astrophysics Data System (ADS)

    Wang, Ziping; Jiang, Zhengxuan; Chen, Liangbin; Li, Yefei; Li, Meixia; Wang, Shaohan

    2018-05-01

    With the advantages of high performance and low loss, interdigital surface acoustic wave (IDT-SAW) transducers are widely used in the fields of nondestructive testing, communication and broadcasting. The production, performance and application of surface acoustic wave (SAW) actuators has become a research hotspot. Based on the basic principle of SAW, an IDT-SAW transducer is designed and fabricated using silk-screen printing in this work. The experiment results show that in terms of SAW performance, the fabricated IDT-SAW transducer can generate standing wave fields comparable to those generated using traditional fabrication methods. The resonant frequency response of the IDT-SAW transducer and SAW attenuation coefficient were obtained by experiments. It has provided a method to test the transducer sensing performance by using fabricated IDT-SAW transducer.

  20. Initial impact and cost of a nationwide population screening campaign for diabetes in Brazil: A follow up study

    PubMed Central

    Toscano, Cristiana M; Duncan, Bruce B; Mengue, Sotero S; Polanczyk, Carísi Anne; Nucci, Luciana B; Costa e Forti, Adriana; Fonseca, Cláudio D; Schmidt, Maria Inês

    2008-01-01

    Background In 2001 Brazilian citizens aged 40 or older were invited to participate in a nationwide population screening program for diabetes. Capillary glucose screening tests and procedures for diagnostic confirmation were offered through the national healthcare system, diagnostic priority being given according to the severity of screening results. The objective of this study is to evaluate the initial impact of the program. Methods Positive testing was defined by a fasting capillary glucose ≥ 100 mg/dL or casual glucose ≥ 140 mg/dL. All test results were tabulated locally and aggregate data by gender and clinical categories were sent to the Ministry of Health. To analyze individual characteristics of screening tests performed, a stratified random sample of 90,106 tests was drawn. To describe the actions taken for positive screenees, a random sub-sample of 4,906 positive screenees was actively followed up through home interviews. Main outcome measures considered were the number of diabetes cases diagnosed and cost per case detected and incorporated into healthcare. Results Of 22,069,905 screening tests performed, we estimate that 3,417,106 (95% CI 3.1 – 3.7 million) were positive and that 346,168 (290,454 – 401,852) new cases were diagnosed (10.1% of positives), 319,157 (92.2%) of these being incorporated into healthcare. The number of screening tests needed to detect one case of diabetes was 64. As many cases of untreated but previously known diabetes were also linked to healthcare providers during the Campaign, the estimated number needed screen to incorporate one case into the healthcare system was 58. Total screening and diagnostic costs were US$ 26.19 million, the cost per diabetes case diagnosed being US$ 76. Results were especially sensitive to proportion of individuals returning for diagnostic confirmation. Conclusion This nationwide population-based screening program, conducted through primary healthcare services, demonstrates the feasibility, within the context of an organized national healthcare system, of screening campaigns for chronic diseases. Although overall costs were significant, cost per new case diagnosed was lower than previously reported. However, cost-effectiveness analysis based on more clinically significant outcomes needs to be conducted before this screening approach can be recommended in other settings. PMID:18808662

  1. Cervical cancer risk levels in Turkey and compliance to the national cervical cancer screening standard.

    PubMed

    Açikgöz, Ayla; Ergör, Gül

    2011-01-01

    Cervical cancer screening with Pap smear test is a cost-effective method. The Ministry of Health in Turkey recommends that it be performed once every five years after age 35. The purpose of this study was to determine the cervical cancer risk levels of women between 35 and 69, and the intervals they have the Pap smear test, and to investigate the relation between the two. This study was performed on 227 women aged between 35 and 69 living in Balçova District of İzmir province. Using the cervical cancer risk index program of Harvard School of Public Health, the cervical cancer risk level of 70% of the women was found below average, 22.1% average, and 7.9% above average. Only 52% of the women have had Pap smear test at least once in their lives. The percentage screening regularly in conformity with the national screening standard was 39.2%. Women in the 40-49 age group, were married, conformed significantly more (p<0.05) to the national screening standard. Compliance also increased with the level of education and decreased with the cervical cancer risk level (p<0.05). A logistic regression model was constructed including age, education level, menstruation state of the women and the economic level of the family. Not having the Pap smear test in conformity with the national cervical cancer screening standard in 35-39 age group was 2.52 times more than 40-49 age group, while it was 3.26 times more in 60-69 age group (p< 0.05). Not having Pap smear test in 35-39 age group more than other groups might result from lack of information on the cervical cancer national screening standard and the necessity of having Pap smear test. As for 60-69 age group, the low education level might cause not having Pap smear test. Under these circumstances, the cervical cancer risk levels should be determined and the individuals should be informed. Providing Pap smear test screening service to individuals in the target group of national screening standard, as a public service may resolve the inequalities due to age and educational differences.

  2. Focused use of drug screening in overdose patients increases impact on management.

    PubMed

    Erdmann, Andreas; Werner, Dominique; Hugli, Olivier; Yersin, Bertrand

    2015-01-01

    Drug poisoning is a common cause for attendance in the emergency department. Several toxicology centres suggest performing urinary drug screens, even though they rarely influence patient management. Measuring the impact on patient management, in a University Emergency Department with approximately 40 000 admissions annually, of a rapid urinary drug screening test using specifically focused indications. Drug screening was restricted to patients having a first psychotic episode or cases demonstrating respiratory failure, coma, seizures, a sympathomimetic toxidrome, severe opiate overdose necessitating naloxone, hypotension, ventricular arrhythmia, acquired long QT or QRS >100 ms, and high-degree heart block. Retrospective analysis of Triage® TOX drug screen tests performed between September 2009 and November 2011, and between January 2013 and March 2014. A total of 262 patients were included, mean age 35 ± 14.6 (standard deviation) years, 63% men; 29% poisoning with alcohol, and 2.3% deaths. Indications for testing were as follows: 34% were first psychotic episodes; 20% had acute respiratory failure; 16% coma; 8% seizures; 8% sympathomimetic toxidromes; 7% severe opioid toxidromes; 4% hypotension; 3% ventricular arrhythmias or acquired long QT intervals on electrocardiogram. A total of 78% of the tests were positive (median two substances, maximum five). The test resulted in drug-specific therapy in 6.1%, drug specific diagnostic tests in 13.3 %, prolonged monitoring in 10.7% of methadone-positive tests, and psychiatric admission in 4.2%. Overall, 34.3% tests influenced patient management. In contrast to previous studies showing modest effects of toxicological testing, restricted use of rapid urinary drug testing increases the impact on management of suspected overdose patients in the ED.

  3. Breast cancer screening (breast self-examination, clinical breast exam, and mammography) in women referred to health centers in Tabriz, Iran.

    PubMed

    Khalili, Azizeh Farshbaf; Shahnazi, Mahnaz

    2010-04-01

    Breast cancer is the most common cancer and the most common cause of death in Iranian women aged 35-55 years. Breast cancer screening comprises breast self-examination (BSE), clinical breast examination (CBE) and mammography. The study aimed to examine the performance of screening methods among women referring to health centers of Tabriz, Iran. This was a descriptive-analytical research carried out on 400 women aged 20-50 years. The samples were chosen through random multistage sampling among health centers of Tabriz then active records of women. A questionnaire and observational checklist was used to elicit socio-demographic information and performance of women towards breast cancer screening methods. Descriptive and inferential statistics (chi-square and Fisher's exact test) were used to analyze the data. Only 18.8% of women did breast self-examination, 19.1% had clinical breast examination and 3.3% had mammogram. Statistical test showed a significant relationship between performing BSE and educational level, employment, income, number of children, breastfeeding history, breastfeeding quality and family history of breast cancer. There was a significant correlation between performing CBE and history of breast tumor and also, between performing the mammography and family history of breast cancer and history of breast tumor (P < 0.05). The findings showed that the performance of breast cancer screening methods was not satisfactory. Performance in high risk women was very desirable than others. The presentation of imperative education about breast cancer screening methods through health staff especially in pregnancy, post-partum and even in pre marriage counseling periods seems necessary.

  4. Genotyping for Human Papillomavirus (HPV) 16/18/52/58 Has a Higher Performance than HPV16/18 Genotyping in Triaging Women with Positive High-risk HPV Test in Northern Thailand

    PubMed Central

    Khunamornpong, Surapan; Settakorn, Jongkolnee; Sukpan, Kornkanok; Suprasert, Prapaporn; Srisomboon, Jatupol; Intaraphet, Suthida; Siriaunkgul, Sumalee

    2016-01-01

    Background Testing for high-risk human papillomavirus DNA (HPV test) has gained increasing acceptance as an alternative method to cytology in cervical cancer screening. Compared to cytology, HPV test has a higher sensitivity for the detection of histologic high-grade squamous intraepithelial lesion or worse (HSIL+), but this could lead to a large colposcopy burden. Genotyping for HPV16/18 has been recommended in triaging HPV-positive women. This study was aimed to evaluate the screening performance of HPV testing and the role of genotyping triage in Northern Thailand. Methods A population-based cervical screening program was performed in Chiang Mai (Northern Thailand) using cytology (conventional Pap test) and HPV test (Hybrid Capture 2). Women who had abnormal cytology or were HPV-positive were referred for colposcopy. Cervical samples from these women were genotyped using the Linear Array assay. Results Of 5,456 women, 2.0% had abnormal Pap test results and 6.5% tested positive with Hybrid Capture 2. Of 5,433 women eligible for analysis, 355 with any positive test had histologic confirmation and 57 of these had histologic HSIL+. The sensitivity for histologic HSIL+ detection was 64.9% for Pap test and 100% for Hybrid Capture 2, but the ratio of colposcopy per detection of each HSIL+ was more than two-fold higher with Hybrid Capture 2 than Pap test (5.9 versus 2.8). Genotyping results were available in 316 samples. HPV52, HPV16, and HPV58 were the three most common genotypes among women with histologic HSIL+. Performance of genotyping triage using HPV16/18/52/58 was superior to that of HPV16/18, with a higher sensitivity (85.7% versus 28.6%) and negative predictive value (94.2% versus 83.9%). Conclusions In Northern Thailand, HPV testing with genotyping triage shows better screening performance than cervical cytology alone. In this region, the addition of genotyping for HPV52/58 to HPV16/18 is deemed necessary in triaging women with positive HPV test. PMID:27336913

  5. Modality dependence and intermodal transfer in the Corsi Spatial Sequence Task: Screen vs. Floor.

    PubMed

    Röser, Andrea; Hardiess, Gregor; Mallot, Hanspeter A

    2016-07-01

    Four versions of the Corsi Spatial Sequence Task (CSST) were tested in a complete within-subject design, investigating whether participants' performance depends on the modality of task presentation and reproduction that put different demands on spatial processing. Presentation of the sequence (encoding phase) and the reproduction (recall phase) were each carried out either on a computer screen or on the floor of a room, involving actual walking in the recall phase. Combinations of the two different encoding and recall procedures result in the modality conditions Screen-Screen, Screen-Floor, Floor-Screen, and Floor-Floor. Results show the expected decrease in performance with increasing sequence length, which is likely due to processing limitations of working memory. We also found differences in performance between the modality conditions indicating different involvements of spatial working memory processes. Participants performed best in the Screen-Screen modality condition. Floor-Screen and Floor-Floor modality conditions require additional working memory resources for reference frame transformation and spatial updating, respectively; the resulting impairment of the performance was about the same in these two conditions. Finally, the Screen-Floor modality condition requires both types of additional spatial demands and led to the poorest performance. Therefore, we suggest that besides the well-known spatial requirements of CSST, additional working memory resources are demanded in walking CSST supporting processes such as spatial updating, mental rotation, reference frame transformation, and the control of walking itself.

  6. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  7. Colorectal Cancer Screening Programme in Spain: Results of Key Performance Indicators After Five Rounds (2000-2012).

    PubMed

    Binefa, Gemma; Garcia, Montse; Milà, Núria; Fernández, Esteve; Rodríguez-Moranta, Francisco; Gonzalo, Núria; Benito, Llúcia; Clopés, Ana; Guardiola, Jordi; Moreno, Víctor

    2016-01-20

    Effective quality assurance is essential in any screening programme. This article provides a unique insight into key quality indicators of five rounds of the first population-based colorectal cancer screening programme implemented in Spain (2000-2012), providing the results according to the type of screening (prevalent or first screen and incident or subsequent screen) and test (guaiac or immunochemical). The total crude participation rate increased from 17.2% (11,011) in the first round to 35.9% (22,988) in the last one. Rescreening rate was very high (88.6% in the fifth round). Positivity rate was superior with the faecal immunochemical test (6.2%) than with the guaiac-based test (0.7%) (p < 0.0001) and detection rates were also better with the immunochemical test. The most significant rise in detection rate was observed for high risk adenoma in men (45.5 per 1,000 screened). Most cancers were diagnosed at an early stage (61.4%) and there was a statistically significant difference between those detected in first or subsequent screening (52.6% and 70.0% respectively; p = 0.024). The availability of these results substantially improves data comparisons and the exchange of experience between screening programmes.

  8. How Strong and Weak Readers Perform on the Developmental Eye Movement Test (DEM): Norms for Latvian School-Aged Children

    ERIC Educational Resources Information Center

    Serdjukova, Jelena; Ekimane, Lasma; Valeinis, Janis; Skilters, Jurgis; Krumina, Gunta

    2017-01-01

    The aim of our study was to determine DEM test performance norms for school-aged children in Latvia, assess how DEM test results correlate with children's reading rates, compare test performance between strong and weak readers. A modified DEM test and a newly developed reading test were administered to 1487 children during a screening survey. Our…

  9. Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.

    PubMed

    Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.

    2003-12-01

    OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.

  10. Screening for Sex Chromosome Aneuploidy by Cell-Free DNA Testing: Patient Choice and Performance.

    PubMed

    Bevilacqua, Elisa; Ordóñez, Elena; Hurtado, Ivan; Rueda, Laura; Mazzone, Eléonora; Cirigliano, Vincenzo; Jani, Jacques C

    2017-08-23

    To study patient choice regarding testing for sex chromosome aneuploidy (SCA) and the performance of cell-free DNA (cfDNA) screening for SCA. Patient choice regarding screening for SCA and factors influencing this choice were evaluated in a single center. In a subsequent two-center study, cases that screened positive for SCA were analyzed to determine the positive predictive value (PPV) for each SCA. In all, 1,957 (61.9%) of the 3,162 patients undergoing cfDNA testing opted for SCA screening. Regression analysis demonstrated that independent predictors of a patient's decision for SCA were earlier gestational age, spontaneous conception, and cfDNA chosen as a primary method of screening. A total of 161 cases screened positive for SCA and follow-up data were available for 118 (73.3%). Forty-six of the 61 cases of 45,X were false-positive results and 15 were concordant with the fetal karyotype (PPV = 24.6%). Seventeen of the 22 cases of 47,XXX were false positive and 5 concordant (PPV = 22.7%). Eleven of the 30 cases of 47,XXY were false positive and 19 concordant (PPV = 63.3%). All 5 cases of 47,XYY were correctly identified, thus yielding a PPV of 100%. More than half of the patients undergoing cfDNA aneuploidy screening also opted for SCA testing, but they were less likely to do so in the presence of an increased risk of trisomy. SCAs involving the X chromosome had a lower PPV than those involving the Y chromosome. © 2017 S. Karger AG, Basel.

  11. Screening for diabetes and prediabetes should be cost-saving in patients at high risk.

    PubMed

    Chatterjee, Ranee; Narayan, K M Venkat; Lipscomb, Joseph; Jackson, Sandra L; Long, Qi; Zhu, Ming; Phillips, Lawrence S

    2013-07-01

    Although screening for diabetes and prediabetes is recommended, it is not clear how best or whom to screen. We therefore compared the economics of screening according to baseline risk. Five screening tests were performed in 1,573 adults without known diabetes--random plasma/capillary glucose, plasma/capillary glucose 1 h after 50-g oral glucose (any time, without previous fast, plasma glucose 1 h after a 50-g oral glucose challenge [GCTpl]/capillary glucose 1 h after a 50-g oral glucose challenge [GCTcap]), and A1C--and a definitive 75-g oral glucose tolerance test. Costs of screening included the following: costs of testing (screen plus oral glucose tolerance test, if screen is positive); costs for false-negative results; and costs of treatment of true-positive results with metformin, all over the course of 3 years. We compared costs for no screening, screening everyone for diabetes or high-risk prediabetes, and screening those with risk factors based on age, BMI, blood pressure, waist circumference, lipids, or family history of diabetes. Compared with no screening, cost-savings would be obtained largely from screening those at higher risk, including those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, with differences of up to -46% of health system costs for screening for diabetes and -21% for screening for dysglycemia110, respectively (all P < 0.01). GCTpl would be the least expensive screening test for most high-risk groups for this population over the course of 3 years. From a health economics perspective, screening for diabetes and high-risk prediabetes should target patients at higher risk, particularly those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, for whom screening can be most cost-saving. GCTpl is generally the least expensive test in high-risk groups and should be considered for routine use as an opportunistic screen in these groups.

  12. Comparison of Traditional and Reverse Syphilis Screening Algorithms in Medical Health Checkups.

    PubMed

    Nah, Eun Hee; Cho, Seon; Kim, Suyoung; Cho, Han Ik; Chai, Jong Yil

    2017-11-01

    The syphilis diagnostic algorithms applied in different countries vary significantly depending on the local syphilis epidemiology and other considerations, including the expected workload, the need for automation in the laboratory and budget factors. This study was performed to investigate the efficacy of traditional and reverse syphilis diagnostic algorithms during general health checkups. In total, 1,000 blood specimens were obtained from 908 men and 92 women during their regular health checkups. Traditional screening and reverse screening were applied to the same specimens using automatic rapid plasma regain (RPR) and Treponema pallidum latex agglutination (TPLA) tests, respectively. Specimens that were reverse algorithm (TPLA) reactive, were subjected to a second treponemal test performed by using the chemiluminescent microparticle immunoassay (CMIA). Of the 1,000 specimens tested, 68 (6.8%) were reactive by reverse screening (TPLA) compared with 11 (1.1%) by traditional screening (RPR). The traditional algorithm failed to detect 48 specimens [TPLA(+)/RPR(-)/CMIA(+)]. The median TPLA cutoff index (COI) was higher in CMIA-reactive cases than in CMIA-nonreactive cases (90.5 vs 12.5 U). The reverse screening algorithm could detect the subjects with possible latent syphilis who were not detected by the traditional algorithm. Those individuals could be provided with opportunities for evaluating syphilis during their health checkups. The COI values of the initial TPLA test may be helpful in excluding false-positive TPLA test results in the reverse algorithm. © The Korean Society for Laboratory Medicine

  13. Performance Characteristics of the Reverse Syphilis Screening Algorithm in a Population With a Moderately High Prevalence of Syphilis.

    PubMed

    Rourk, Angela R; Nolte, Frederick S; Litwin, Christine M

    2016-11-01

    With the recent introduction of automated treponemal tests, a new reverse syphilis algorithm has been proposed and now used by many clinical laboratories. We analyzed the impact of instituting the reverse screening syphilis algorithm in a laboratory that serves a geographic area with a moderately high prevalence of syphilis infection. Serum samples sent for syphilis testing were tested using a treponemal enzyme immunoassay (EIA) as the screening assay. EIA reactive samples were tested by rapid plasma reagin (RPR) and titered to end point if reactive. RPR nonreactive samples were analyzed by the Treponema pallidum particle agglutination test (TP-PA). Pertinent medical records were reviewed for false-reactive screens and samples with evidence of past syphilis infection. Among 10,060 patients tested, 502 (5%) were reactive on the initial EIA screen. The RPR was reactive in 150 (1.5%). TP-PA testing determined that 103 (1.0%) were falsely reactive on initial EIA screen. The reverse screening algorithm, however, identified 242 (2.4%) with evidence of latent, secondary, or past syphilis, 21 of whom had no or unknown prior treatment with antibiotics. Despite a 1.0% false-reactive rate, the reverse syphilis algorithm detected 21 patients with possible latent syphilis that may have gone undetected by traditional syphilis screening. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Comparison of performance on the Shipley Institute of Living Scale, air traffic control specialist selection test, and FAA Academy screen.

    DOT National Transportation Integrated Search

    1992-11-01

    This study was conducted to establish norms for ATCS personnel on a group test of intellectual functioning, the Shipley Institute of Living Scale (SILS), to screen subjects for future research on the effects of Air Traffic Control Specialist (ATCS) r...

  15. Cancer screening among Vietnamese in Hawaii.

    PubMed

    Nguyen, Ly T; Withy, Kelley; Nguyen, Michelle M; Yamada, Seiji

    2003-07-01

    To determine the extent of utilization of cancer screening services by Vietnamese in Hawaii, who had sought medical care from 1996 through 2000. A chart review of 952 adult Vietnamese patients was performed. Of all eligible women, 52% and 26% had Papanicolaou test and mammogram, respectively. Among men age 45 and over, 8.4% had prostate-specific antigen test and 3.4% had digital rectal exam. Flexible sigmoidoscopy and colonoscopy were not utilized by patients. This is the first study to examine the use of cancer screening tests by Vietnamese immigrants in Hawaii. Our findings of lower utilization rates in cancer screening by both male and female strongly support efforts to educate and promote preventive health for this population.

  16. Automated screening of propulsion system test data by neural networks, phase 1

    NASA Technical Reports Server (NTRS)

    Hoyt, W. Andes; Whitehead, Bruce A.

    1992-01-01

    The evaluation of propulsion system test and flight performance data involves reviewing an extremely large volume of sensor data generated by each test. An automated system that screens large volumes of data and identifies propulsion system parameters which appear unusual or anomalous will increase the productivity of data analysis. Data analysts may then focus on a smaller subset of anomalous data for further evaluation of propulsion system tests. Such an automated data screening system would give NASA the benefit of a reduction in the manpower and time required to complete a propulsion system data evaluation. A phase 1 effort to develop a prototype data screening system is reported. Neural networks will detect anomalies based on nominal propulsion system data only. It appears that a reasonable goal for an operational system would be to screen out 95 pct. of the nominal data, leaving less than 5 pct. needing further analysis by human experts.

  17. Use of the Analysis of the Volatile Faecal Metabolome in Screening for Colorectal Cancer

    PubMed Central

    2015-01-01

    Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT. PMID:26086914

  18. Performance of the OraQuick HCV rapid antibody test for screening exposed patients in a hepatitis C outbreak investigation.

    PubMed

    Gao, Fengxiang; Talbot, Elizabeth A; Loring, Carol H; Power, Jill J; Dionne-Odom, Jodie; Alroy-Preis, Sharon; Jackson, Patricia; Bean, Christine L

    2014-07-01

    During a nosocomial hepatitis C outbreak, emergency public clinics employed the OraQuick HCV rapid antibody test on site, and all results were verified by a standard enzyme immunoassay (EIA). Of 1,157 persons, 1,149 (99.3%) exhibited concordant results between the two tests (16 positive, 1,133 negative). The sensitivity, specificity, positive predictive value, and negative predictive value were 94.1%, 99.5%, 72.7%, and 99.9%, respectively. OraQuick performed well as a screening test during an outbreak investigation and could be integrated into future hepatitis C virus (HCV) outbreak testing algorithms. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  19. A review of the management of positive biochemical screening for phaeochromocytoma and paraganglioma: a salutary tale.

    PubMed

    Garrahy, A; Casey, R; Wall, D; Bell, M; O'Shea, P M

    2015-07-01

    Phaeochromocytomas (PC) and paragangliomas (PGL) are rare neuroendocrine tumours of chromaffin cells. Diagnosis depends on biochemical evidence of excessive production of catecholamines. This is straightforward when test results are orders of magnitude above the concentrations expected in healthy individuals and those with essential hypertension. Equivocal results pose a management dilemma. We reviewed biochemical screens that were positive and the ensuing management for PC/PGL at our institution. The objective was to inform the development of a standardised approach to investigation and clinical follow-up. All records of positive biochemical screening for PC/PGL were extracted from the laboratory information system between January 2004 and June 2012. Clinical notes of patients with positive results were reviewed. A total of 2749 biochemical screens were performed during the evaluation period. Of these, 106 (3.9%) performed on 82 patients were positive. Chart review determined that 12/82 patients had histologically confirmed PC/PG. Of the 70 patients remaining, the most common indication for biochemical screening was hypertension and the medical subspecialty most frequently requesting the test was Endocrinology. The primary team carried out repeat testing on 35/70 (50%) patients and in 29 results normalised. Notably, 35/70 (50%) patients did not have any follow-up of positive test results. This study highlights the necessity for a standardised diagnostic protocol for PC/PGL. We suggest that appropriate follow-up of borderline-elevated results should first include repeat biochemical testing. This should be performed under standardised pre-analytical conditions and where possible off all potentially interfering medications, measuring plasma free metadrenalines. © 2015 John Wiley & Sons Ltd.

  20. Three-Item Direct Observation Screen (TIDOS) for Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Oner, Pinar; Oner, Ozgur; Munir, Kerim

    2014-01-01

    We compared ratings on the Three-Item Direct Observation Screen test for autism spectrum disorders completed by pediatric residents with the Social Communication Questionnaire parent reports as an augmentative tool for improving autism spectrum disorder screening performance. We examined three groups of children (18-60 months) comparable in age…

  1. T-SPOT.TB Interferon-γ Release Assay Performance in Healthcare Worker Screening at Nineteen U.S. Hospitals.

    PubMed

    King, Thomas C; Upfal, Mark; Gottlieb, Andrew; Adamo, Philip; Bernacki, Edward; Kadlecek, Chris P; Jones, Jeffrey G; Humphrey-Carothers, Frances; Rielly, Albert F; Drewry, Pamela; Murray, Kathy; DeWitt, Marcie; Matsubara, Janet; O'Dea, Louis; Balser, John; Wrighton-Smith, Peter

    2015-08-01

    Interferon-γ release assays have significant advantages over tuberculin skin testing in many clinical situations. However, recent studies have called into question their reliability in serial testing of healthcare workers because of reportedly high rates of positivity and high conversion/reversion rates on retesting. To define the performance characteristics of the T-SPOT.TB test, an interferon-γ release assay, during serial screening programs of healthcare workers at 19 U.S. hospitals. A total of 42,155 T-SPOT.TB test results from healthcare workers at 19 geographically diverse hospitals obtained for routine tuberculosis screening programs were analyzed to determine the rates of positivity, reversion, and conversion in serial testing data. In 19,630 evaluable serial pairs from 16,076 healthcare workers, the mean test positivity rate was 2.3% (range, 0.0-27.4%). The mean conversion rate was 0.8% (range, 0.0-2.5%), and the mean reversion rate was 17.6%. Positivity and conversion rates correlated with known tuberculosis risk factors including age and sex. The observed specificity of the T-SPOT.TB test was at least 98.6%. The high concordance and test completion rates in this study suggest that the T-SPOT.TB test is a reliable tool for healthcare worker serial screening. As expected, the observed positivity rates were lower compared with the tuberculin skin test, likely reflecting the higher specificity of this test. Furthermore, the observed rates of conversion were low and significantly correlated with the geographic incidence of tuberculosis. Our findings suggest that the T-SPOT.TB test is an accurate and reliable way to screen healthcare workers.

  2. Cervical Cancer Screening in Low-Resource Settings: A Cost-Effectiveness Framework for Valuing Tradeoffs between Test Performance and Program Coverage

    PubMed Central

    Campos, Nicole G.; Castle, Philip E.; Wright, Thomas C.; Kim, Jane J.

    2016-01-01

    As cervical cancer screening programs are implemented in low-resource settings, protocols are needed to maximize health benefits under operational constraints. Our objective was to develop a framework for examining health and economic tradeoffs between screening test sensitivity, population coverage, and follow-up of screen-positive women, to help decision makers identify where program investments yield the greatest value. As an illustrative example, we used an individual-based Monte Carlo simulation model of the natural history of human papillomavirus (HPV) and cervical cancer calibrated to epidemiologic data from Uganda. We assumed once in a lifetime screening at age 35 with two-visit HPV DNA testing or one-visit visual inspection with acetic acid (VIA). We assessed the health and economic tradeoffs that arise between 1) test sensitivity and screening coverage; 2) test sensitivity and loss to follow-up (LTFU) of screen-positive women; and 3) test sensitivity, screening coverage, and LTFU simultaneously. The decline in health benefits associated with sacrificing HPV DNA test sensitivity by 20% (e.g., shifting from provider- to self-collection of specimens) could be offset by gains in coverage if coverage increased by at least 20%. When LTFU was 10%, two-visit HPV DNA testing with 80-90% sensitivity was more effective and more cost-effective than one-visit VIA with 40% sensitivity, and yielded greater health benefits than VIA even as VIA sensitivity increased to 60% and HPV test sensitivity declined to 70%. As LTFU increased, two-visit HPV DNA testing became more costly and less effective than one-visit VIA. Setting-specific data on achievable test sensitivity, coverage, follow-up rates, and programmatic costs are needed to guide programmatic decision making for cervical cancer screening. PMID:25943074

  3. Association between television, movie, and video game exposure and school performance.

    PubMed

    Sharif, Iman; Sargent, James D

    2006-10-01

    The relationship between media exposure and school performance has not been studied extensively in adolescents. The purpose of this work was to test the relative effects of television, movie, and video game screen time and content on adolescent school performance. We conducted a population-based cross-sectional survey of middle school students (grades 5-8) in the Northeastern United States. We looked at weekday television and video game screen time, weekend television and video game screen time, cable movie channel availability, parental R-rated movie restriction, and television content restriction. The main outcome was self-report of school performance (excellent, good, average, or below average). We used ordinal logistic-regression analysis to test the independent effects of each variable, adjusting for demographics, child personality, and parenting style. There were 4508 students who participated in the study; gender was equally represented, and 95% were white. In multivariate analyses, after adjusting for other covariates, the odds of poorer school performance increased with increasing weekday television screen time and cable movie channel availability and decreased with parental restriction of television content restriction. As compared with children whose parents never allowed them to watch R-rated movies, children who watched R-rated movies once in a while, sometimes, or all of the time had significantly increased cumulative odds of poorer school performance. Weekend screen time and video game use were not associated with school performance. We found that both content exposure and screen time had independent detrimental associations with school performance. These findings support parental enforcement of American Academy of Pediatrics guidelines for media time (particularly weekdays) and content limits to enhance school success.

  4. The bimanual ovarian palpation examination in the Prostate, Lung, Colorectal and Ovarian cancer screening trial: Performance and complications.

    PubMed

    Doroudi, Maryam; Kramer, Barnett S; Pinsky, Paul F

    2017-12-01

    Objective To provide evidence about the performance characteristics and consequences of bimanual ovarian palpation. Setting and methods The Prostate, Lung, Colorectal and Ovarian cancer screening trial randomized 154,900 individuals to either an intervention or control arm. Enrolled eligible participants were aged 55-74, had no history of trial cancers, and no current treatment for cancer. Intervention arm women received CA-125 tests and transvaginal ultrasound. Bimanual ovarian palpation was offered annually during the first four years of the trial. Bimanual ovarian palpation-specific sensitivity and specificity were calculated, as were rates of diagnostic procedures and resulting complications following positive bimanual ovarian palpation screens. Results A total of 20,872 women received at least one bimanual ovarian palpation, with 50,498 total bimanual ovarian palpation examinations performed. The sensitivity and specificity of bimanual ovarian palpation were 5.1% (2/39) and 99.0% (49,957/50,459), respectively; no cases were detected by bimanual ovarian palpation alone. Rates for most follow-up procedures for abnormal results in women without ovarian cancer were higher among the group with another screening test positive, except for pelvic exam, where rates were similar. No complications were reported in the bimanual ovarian palpation-only positive group. Conclusion Low sensitivity of bimanual ovarian palpation alone and in combination with other tests argue against using bimanual ovarian palpation as a screening test for ovarian cancer in asymptomatic women.

  5. Duration of stimulus presentation and screening for perceptual disabilities.

    PubMed

    Rohr, M E; Ayers, J B

    1975-02-01

    This study examined the effects of increasing the stimulus-presentation time of a motion picture test for identifying perceptual disabilities in the performance of Ss in regular first and fourth grade classrooms and on a sample of Ss in special education classes who had been identified as having varying degrees of perceptual deficiencies. The length of stimulus presentation increased the total performance of Ss on the motion picture test but did not add to the value of the instrument as a screening device.

  6. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    PubMed

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  7. Effect of vibration on retention characteristics of screen acquisition systems. [for surface tension propellant acquisition

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.; Aydelott, J. C.

    1978-01-01

    The design of surface tension propellant acquisition systems using fine-mesh screen must take into account all factors that influence the liquid pressure differentials within the system. One of those factors is spacecraft vibration. Analytical models to predict the effects of vibration have been developed. A test program to verify the analytical models and to allow a comparative evaluation of the parameters influencing the response to vibration was performed. Screen specimens were tested under conditions simulating the operation of an acquisition system, considering the effects of such parameters as screen orientation and configuration, screen support method, screen mesh, liquid flow and liquid properties. An analytical model, based on empirical coefficients, was most successful in predicting the effects of vibration.

  8. Colorectal cancer screening programme by faecal occult blood test in Tuscany: first round results.

    PubMed

    Grazzini, G; Castiglione, G; Ciabattoni, C; Franceschini, F; Giorgi, D; Gozzi, S; Mantellini, P; Lopane, P; Perco, M; Rubeca, T; Salvadori, P; Visioli, C B; Zappa, M

    2004-02-01

    Screening with faecal occult blood test (FOBT) has been shown to be effective in reducing mortality from colorectal cancer. Tuscany was the first region in Italy in which a screening programme for colorectal cancer by FOBT was initiated region-wide. The aim of the paper was to describe organizational aspects, a quality control model and the results of this experience. From June 2000 to December 2001, 192583 subjects aged 50-70 were invited to undergo a 1-day immunochemical test without any dietary restriction. A total of 78505 subjects (41%) performed the screening test, of whom 4537 responders had a positive test result (5.8%). Among them, 1122 refused any form of assessment or underwent a colonoscopy outside the screening referral centres, with an overall assessment compliance of 75.3%. Malignancies were found in 193 patients and at least a high-risk adenomatous polyp in 692 patients. In about a quarter of the positive subjects who underwent assessment, cancer or high-risk adenoma was detected. In conclusion, data from this experience supported the feasibility of biennial colorectal screening programme by FOBT, particularly regarding invitation compliance and positivity rate. Further efforts are necessary to implement screening extension and to improve data collection.

  9. Cryogenic Capillary Screen Heat Entrapment

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L.G.; Hastings, L.J.; Stathman, G.

    2007-01-01

    Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of sub-cooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: "To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs.?"Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, "200x1400" and "325x2300", both with Twill Dutch Weave. Upon consideration of both the water and LN2 data it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.

  10. Reproducibility of self-reported pap test utilization in middle-aged African-American women.

    PubMed

    Hoyo, Cathrine; Ostbye, Truls; Skinner, Celette S; Yarnall, Kimberly S H; Chowdhary, Jaspreet

    2005-01-01

    Both clinicians who perform Pap tests and prescribe re-screens and public health officials, who periodically evaluate the success of Pap test screening programs, often depend on women to self-report their most recent Pap test. However, reliability of self-reported Pap test utilization is putatively low, and even lower in African-American women compared to Whites. Between 2001 and 2002, Pap test screening histories were obtained from 144 African-American women, aged 45 to 64 years at two in-person interviews conducted three to six weeks apart. Reproducibility of self-reported Pap test was substantial (kappa=0.64; 95% confidence interval: .46-.82), with the highest agreement among women with greater income and educational attainment, and those who were younger. This level of reproducibility is likely sufficient both to evaluate the population coverage of public health screening programs and for prescribing re-screens among younger African-American women and those of higher income and education. Not using self-reports to base clinic decisions may still be prudent among those with less education.

  11. The optimal sequence and selection of screening test items to predict fall risk in older disabled women: the Women's Health and Aging Study.

    PubMed

    Lamb, Sarah E; McCabe, Chris; Becker, Clemens; Fried, Linda P; Guralnik, Jack M

    2008-10-01

    Falls are a major cause of disability, dependence, and death in older people. Brief screening algorithms may be helpful in identifying risk and leading to more detailed assessment. Our aim was to determine the most effective sequence of falls screening test items from a wide selection of recommended items including self-report and performance tests, and to compare performance with other published guidelines. Data were from a prospective, age-stratified, cohort study. Participants were 1002 community-dwelling women aged 65 years old or older, experiencing at least some mild disability. Assessments of fall risk factors were conducted in participants' homes. Fall outcomes were collected at 6 monthly intervals. Algorithms were built for prediction of any fall over a 12-month period using tree classification with cross-set validation. Algorithms using performance tests provided the best prediction of fall events, and achieved moderate to strong performance when compared to commonly accepted benchmarks. The items selected by the best performing algorithm were the number of falls in the last year and, in selected subpopulations, frequency of difficulty balancing while walking, a 4 m walking speed test, body mass index, and a test of knee extensor strength. The algorithm performed better than that from the American Geriatric Society/British Geriatric Society/American Academy of Orthopaedic Surgeons and other guidance, although these findings should be treated with caution. Suggestions are made on the type, number, and sequence of tests that could be used to maximize estimation of the probability of falling in older disabled women.

  12. Current Status of Testing for Microdeletion Syndromes and Rare Autosomal Trisomies Using Cell-Free DNA Technology.

    PubMed

    Yaron, Yuval; Jani, Jacques; Schmid, Maximilian; Oepkes, Dick

    2015-11-01

    Noninvasive prenatal testing using cell-free DNA in maternal blood for trisomy 21 was introduced in 2011. This technology has continuously evolved with the addition of screening for trisomy 18 and trisomy 13 followed by the inclusion of sex chromosome aneuploidies. Expanded noninvasive prenatal test panels have recently become available, which enable screening for microdeletion syndromes such as the 22q11.2 deletion (associated with the velocardiofacial syndrome) and others. However, the performance data for these microdeletion syndromes are derived from a small number of samples, mostly generated in vitro. Rigorous performance evaluation, as was done at least for trisomy 21 testing using cell-free DNA analysis, is difficult to perform given the rarity of each condition. In addition, detection rates may vary considerably depending on deletion size. Importantly, positive predictive values (PPVs), strongly influenced by the low prevalence, are expected to be significantly lower than 10% for most conditions. Thus, screening in an average-risk population is likely to have many more false-positives than affected cases detected. Conversely, testing in a high-risk population such as fetuses with cardiac anomalies may have higher PPVs, but a negative result needs to be considered carefully as a result of uncertain information about detection rates and a significant residual risk for other copy number variants and single gene disorders. This article integrates current knowledge on cell-free DNA testing for microdeletions with the aim to assist clinicians and policymakers in designing optimal programs for screening in pregnancy.

  13. Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.

    PubMed

    Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S

    2012-01-01

    Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.

  14. Expanded HIV Testing Strategy Leveraging the Electronic Medical Record Uncovers Undiagnosed Infection Among Hospitalized Patients.

    PubMed

    Felsen, Uriel R; Cunningham, Chinazo O; Heo, Moonseong; Futterman, Donna C; Weiss, Jeffrey M; Zingman, Barry S

    2017-05-01

    Routine HIV testing of hospitalized patients is recommended, but few strategies to expand testing in the hospital setting have been described. We assessed the impact of an electronic medical record (EMR) prompt on HIV testing for hospitalized patients. We performed a pre-post study at 3 hospitals in the Bronx, NY. We compared the proportion of admissions of patients 21-64 years old with an HIV test performed, characteristics of patients tested, and rate of new HIV diagnoses made by screening while an EMR prompt recommending HIV testing was inactive vs. active. The prompt appeared for patients with no previous HIV test or a high-risk diagnosis after their last HIV test. Among 36,610 admissions while the prompt was inactive, 9.5% had an HIV test performed. Among 18,943 admissions while the prompt was active, 21.8% had an HIV test performed. Admission while the prompt was active was associated with increased HIV testing among total admissions [adjusted odds ratio (aOR) 2.78, 95% confidence interval (CI): 2.62 to 2.96], those without a previous HIV test (aOR 4.03, 95% CI: 3.70 to 4.40), and those with a previous negative test (aOR 1.52, 95% CI: 1.37 to 1.68) (P < 0.0001 for all). Although the prompt was active, testing increased across all patient characteristics. New HIV diagnoses made by screening increased from 8.2/100,000 admissions to 37.0/100,000 admissions while the prompt was inactive and active, respectively (OR 4.51 95% CI: 1.17 to 17.45, P = 0.03). An EMR prompt for hospitalized patients was associated with a large increase in HIV testing, a diversification of patients tested, and an increase in diagnoses made by screening.

  15. Tuberculosis after liver transplantation in a large center in New York City: QuantiFERON® -TB Gold-based pre-transplant screening performance and active tuberculosis post-transplant.

    PubMed

    Hand, Jonathan; Sigel, Keith; Huprikar, Shirish; Hamula, Camille; Rana, Meena

    2018-04-01

    Pre-transplant screening for latent tuberculosis infection (LTBI) is a complex consideration that varies by institution. Inconsistent performance of interferon-gamma release assay (IGRA) further complicates screening. Data regarding LTBI screening outcomes and test characteristics in a large, foreign-born pre-transplant population within the United States are limited. In this retrospective study, patients who received QuantiFERON ® -TB Gold (QFT) prior to liver transplantation (LT) were included. Characteristics of patients were compared by QFT result, and predictors of indeterminate results were evaluated. Similar comparisons were performed between patients who developed active TB and those who did not. Of 148 patients screened, the rate of positive, indeterminate, and negative testing was 13.5% (20/148), 27% (40/148), and 59% (88/148), respectively. An indeterminate QFT result was more than 16 times more likely in patients with a Model for End-stage Liver Disease score >25 (odds ratio [OR] 16.7; 95% confidence interval [CI], 2.1-132.0; P = .008) and more than 4 times when performed in our institution's lab compared with commercial lab (OR 4.1; 95% CI, 1.34-12.44; P = .013). The overall TB incidence was 1102/100 000 transplant cases. No patient who developed active TB had a positive QFT. All were born outside of the United States (P = .06) and had pre-transplantation chest imaging demonstrating granulomatous disease (P = .006). Our experience further highlights the challenges of LTBI screening prior to LT and suggests that QFT may be a poor predictor of active TB in higher risk pre-transplant populations. Candidates should be screened as early as possible to optimize QFT performance, and local epidemiological data should be used to create institution-specific screening protocols in areas with large populations from TB-endemic regions. Management should consider TB risk factors, QFT, and imaging instead of reliance on QFT testing alone. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Readiness to perform testing : a critical analysis of the concept and current practices.

    DOT National Transportation Integrated Search

    1993-08-01

    Readiness to Perform (RTP) testing has become an increasingly popular alternative to biochemical screening as a method for assessing risk factors (i.e., drug, alcohol, fatigue, etc.) in the workplace. The focus of RTP testing is on the assessment of ...

  17. Evaluation of the Premi Test and comparison with the One-Plate Test for the detection of antimicrobials in kidney.

    PubMed

    Cantwell, H; O'Keeffe, M

    2006-02-01

    The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.

  18. Can a virtual reality cognitive training application fulfill a dual role? Using the virtual supermarket cognitive training application as a screening tool for mild cognitive impairment.

    PubMed

    Zygouris, Stelios; Giakoumis, Dimitrios; Votis, Konstantinos; Doumpoulakis, Stefanos; Ntovas, Konstantinos; Segkouli, Sofia; Karagiannidis, Charalampos; Tzovaras, Dimitrios; Tsolaki, Magda

    2015-01-01

    Recent research advocates the potential of virtual reality (VR) applications in assessing cognitive functions highlighting the possibility of using a VR application for mild cognitive impairment (MCI) screening. The aim of this study is to investigate whether a VR cognitive training application, the virtual supermarket (VSM), can be used as a screening tool for MCI. Two groups, one of healthy older adults (n = 21) and one of MCI patients (n = 34), were recruited from day centers for cognitive disorders and administered the VSM and a neuropsychological test battery. The performance of the two groups in the VSM was compared and correlated with performance in established neuropsychological tests. At the same time, the effectiveness of a combination of traditional neuropsychological tests and the VSM was examined. VSM displayed a correct classification rate (CCR) of 87.30% when differentiating between MCI patients and healthy older adults, while it was unable to differentiate between MCI subtypes. At the same time, the VSM correlates with various established neuropsychological tests. A limited number of tests were able to improve the CCR of the VSM when combined with the VSM for screening purposes. VSM appears to be a valid method of screening for MCI in an older adult population though it cannot be used for MCI subtype assessment. VSM's concurrent validity is supported by the large number of correlations between the VSM and established tests. It is considered a robust test on its own as the inclusion of other tests failed to improve its CCR significantly.

  19. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Which BRCA genetic testing programs are ready for implementation in health care? A systematic review of economic evaluations.

    PubMed

    D'Andrea, Elvira; Marzuillo, Carolina; De Vito, Corrado; Di Marco, Marco; Pitini, Erica; Vacchio, Maria Rosaria; Villari, Paolo

    2016-12-01

    There is considerable evidence regarding the efficacy and effectiveness of BRCA genetic testing programs, but whether they represent good use of financial resources is not clear. Therefore, we aimed to identify the main health-care programs for BRCA testing and to evaluate their cost-effectiveness. We performed a systematic review of full economic evaluations of health-care programs involving BRCA testing. Nine economic evaluations were included, and four main categories of BRCA testing programs were identified: (i) population-based genetic screening of individuals without cancer, either comprehensive or targeted based on ancestry; (ii) family history (FH)-based genetic screening, i.e., testing individuals without cancer but with FH suggestive of BRCA mutation; (iii) familial mutation (FM)-based genetic screening, i.e., testing individuals without cancer but with known familial BRCA mutation; and (iv) cancer-based genetic screening, i.e., testing individuals with BRCA-related cancers. Currently BRCA1/2 population-based screening represents good value for the money among Ashkenazi Jews only. FH-based screening is potentially very cost-effective, although further studies that include costs of identifying high-risk women are needed. There is no evidence of cost-effectiveness for BRCA screening of all newly diagnosed cases of breast/ovarian cancers followed by cascade testing of relatives, but programs that include tools for identifying affected women at higher risk for inherited forms are promising. Cost-effectiveness is highly sensitive to the cost of BRCA1/2 testing.Genet Med 18 12, 1171-1180.

  1. Using pretest data to screen low-reactivity individuals in the autonomic-based concealed information test.

    PubMed

    Matsuda, Izumi; Ogawa, Tokihiro; Tsuneoka, Michiko; Verschuere, Bruno

    2015-03-01

    The concealed information test (CIT) can be used to assess whether an individual possesses crime-related information. However, its discrimination performance has room for improvement. We examined whether screening out participants who do not respond distinctively on a pretest improves the diagnosticity of a mock-crime CIT. Before conducting the CIT, we gave a pretest to 152 participants, 80 of whom were assigned as guilty. Pretest screening significantly improved the diagnostic value of the mock-crime CIT; however, it also led to a substantial number of undiagnosed participants (33.6%). Pretest screening holds promise, but its application would benefit from dedicated measures for screening out participants. © 2014 Society for Psychophysiological Research.

  2. Diagnostic Validity of High-Density Barium Sulfate in Gastric Cancer Screening: Follow-up of Screenees by Record Linkage with the Osaka Cancer Registry

    PubMed Central

    Yamamoto, Kenyu; Yamazaki, Hideo; Kuroda, Chikazumi; Kubo, Tsugio; Oshima, Akira; Katsuda, Toshizo; Kuwano, Tadao; Takeda, Yoshihiro

    2010-01-01

    Background The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate. Methods The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated. Results The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests. Conclusions Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis. PMID:20551581

  3. Attitudes toward self-sampling for cervical cancer screening among primary care attendees living on the US-Mexico border.

    PubMed

    Penaranda, Eribeth; Molokwu, Jennifer; Hernandez, Ingrid; Salaiz, Rebekah; Nguyen, Norma; Byrd, Theresa; Shokar, Navkiran

    2014-07-01

    Hispanic women living along the US border with Mexico have one of the highest cervical cancer mortality rates in the nation, owing in part to lower rates of screening. The barriers to screening in this population include lack of access to care and fear of and embarrassment about the pelvic examination. Screening for oncogenic or high-risk human papillomavirus during cervical cytology has been added to screening recommendations. A novel method for human papillomavirus testing is self-sampling, in which women collect their own cervicovaginal samples. There is lack of information about the acceptability of self-sampling as an alternative to cytology for cervical cancer screening in women living along the US-Mexico border. We conducted five focus groups with women between the ages of 30 and 65 who were primary care patients of clinics along the US-Mexico border. We used constructs from different health behavioral theories as a framework for the interview guide. A total of 21 women participated in the focus groups, 80% of whom were Hispanic; mean age was 53.4 (standard deviation 7.9). More than one-third (38%) of the participants had not undergone a Papanicolaou test in the last 3 years. Women identified the perceived benefits of self-sampling as ease, convenience, practicability, less embarrassment, and need for child care as compared with a Papanicolaou test. The main barrier to self-sampling was concern about not performing the test correctly. In this qualitative study, we found positive attitudes toward self-sampling among women living along the US border with Mexico. Further research is needed to evaluate interventions that address women's low levels of self-efficacy to perform the test and to evaluate the effectiveness of self-sampling in increasing cervical cancer screening rates.

  4. Performance of prenatal screening using maternal serum and ultrasound markers for Down syndrome in Chinese women: a systematic review and meta-analysis.

    PubMed

    Tu, S; Rosenthal, M; Wang, D; Huang, J; Chen, Y

    2016-09-01

    Controversies about the performance of conventional prenatal screening using maternal serum and ultrasound markers (PSMSUM) in detecting Down syndrome (DS) have been raised as a result of a recently available noninvasive prenatal test based on cell-free fetal DNA sequencing. To evaluate the screening performance of PSMSUM in detecting DS in Chinese women. An exhaustive literature search of MEDLINE, Embase, the Cochrane Library, ISI Web of Science and China BioMedical Disc. Primary studies, published from January 2004 to November 2014, which examined the screening accuracy of PSMSUM in pregnant Chinese women, compared with a reference standard, either chromosomal verification or inspection of the newborn. Data were extracted as screening positive/negative results for Down and non-Down syndrome pregnancies, allowing estimation of sensitivities and specificities. Risks of bias within and across studies were assessed. Screening accuracy measures were pooled using a bivariate random effects regression model. Seventy-eight studies, involving six categories of PSMSUM, were included. Second-trimester double serum [pooled sensitivity (SEN) = 0.80, pooled specificity (SPE) = 0.95] and triple-serum (pooled SEN = 0.79, pooled SPE = 0.96) screening were the predominant PSMSUM methods. The screening performances of these methods achieved the national standard but varied enormously across studies. First-trimester combined screening (pooled SEN = 0.92, pooled SPE = 0.93) and second-trimester quadruple serum screening (median SEN = 0.86, median SPE = 0.96) performed better, but were rarely used. Second-trimester maternal serum screening has the potential to achieve satisfactory screening performance in middle- and low-income countries. The reported enormous range in screening performance of second-trimester PSMSUM calls for urgent implementation of methods for performance optimization. Meta-analysis results show good accuracy of maternal serum and ultrasound screening for trisomy 21 in Chinese women. © 2016 Royal College of Obstetricians and Gynaecologists.

  5. Effectiveness of the "Timed Up and Go" (TUG) and the Chair test as screening tools for geriatric fall risk assessment in the ED.

    PubMed

    Chow, Richard B; Lee, Andre; Kane, Bryan G; Jacoby, Jeanne L; Barraco, Robert D; Dusza, Stephen W; Meyers, Matthew C; Greenberg, Marna Rayl

    2018-06-07

    We sought to evaluate the effectiveness of the "Timed Up and Go" (TUG) and the Chair test as screening tools in the Emergency Department (ED), stratified by sex. This prospective cohort study was conducted at a Level 1 Trauma center. After consent, subjects performed the TUG and the Chair test. Subjects were contacted for phone follow-up and asked to self-report interim falling. Data from 192 subjects were analyzed. At baseline, 71.4% (n = 137) screened positive for increased falls risk based on the TUG evaluation, and 77.1% (n = 148) scored below average on the Chair test. There were no differences by patient sex. By the six-month evaluation 51 (26.6%) study participants reported at least one fall. Females reported a non-significant higher prevalence of falls compared to males (29.7% versus 22.2%, p = 0.24). TUG test had a sensitivity of 70.6% (95% CI: 56.2%-82.5%), a specificity of 28.4% (95% CI: 21.1%-36.6%), a positive predictive (PP) value 26.3% (95% CI: 19.1%-34.5%) and a negative predictive (NP) value of 72.7% (95% CI: 59.0%-83.9%). Similar results were observed with the Chair test. It had a sensitivity of 78.4% (95% CI: 64.7%-88.7%), a specificity of 23.4% (95% CI: 16.7%-31.3%), a PP value 27.0% (95% CI: 20.1%-34.9%) and a NP value of 75.0% (95% CI: 59.7%-86.8%). No significant differences were observed between sexes. There were no sex specific significant differences in TUG or Chair test screening performance. Neither test performed well as a screening tool for future falls in the elderly in the ED setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Cost-Effectiveness Analysis of Different Genetic Testing Strategies for Lynch Syndrome in Taiwan.

    PubMed

    Chen, Ying-Erh; Kao, Sung-Shuo; Chung, Ren-Hua

    2016-01-01

    Patients with Lynch syndrome (LS) have a significantly increased risk of developing colorectal cancer (CRC) and other cancers. Genetic screening for LS among patients with newly diagnosed CRC aims to identify mutations in the disease-causing genes (i.e., the DNA mismatch repair genes) in the patients, to offer genetic testing for relatives of the patients with the mutations, and then to provide early prevention for the relatives with the mutations. Several genetic tests are available for LS, such as DNA sequencing for MMR genes and tumor testing using microsatellite instability and immunohistochemical analyses. Cost-effectiveness analyses of different genetic testing strategies for LS have been performed in several studies from different countries such as the US and Germany. However, a cost-effectiveness analysis for the testing has not yet been performed in Taiwan. In this study, we evaluated the cost-effectiveness of four genetic testing strategies for LS described in previous studies, while population-specific parameters, such as the mutation rates of the DNA mismatch repair genes and treatment costs for CRC in Taiwan, were used. The incremental cost-effectiveness ratios based on discounted life years gained due to genetic screening were calculated for the strategies relative to no screening and to the previous strategy. Using the World Health Organization standard, which was defined based on Taiwan's Gross Domestic Product per capita, the strategy based on immunohistochemistry as a genetic test followed by BRAF mutation testing was considered to be highly cost-effective relative to no screening. Our probabilistic sensitivity analysis results also suggest that the strategy has a probability of 0.939 of being cost-effective relative to no screening based on the commonly used threshold of $50,000 to determine cost-effectiveness. To the best of our knowledge, this is the first cost-effectiveness analysis for evaluating different genetic testing strategies for LS in Taiwan. The results will be informative for the government when considering offering screening for LS in patients newly diagnosed with CRC.

  7. Nutritional Screening of Children: A Manual for Screening & Followup.

    ERIC Educational Resources Information Center

    Bureau of Community Health Services (DHHS/PHS), Rockville, MD.

    This manual shows health providers how to perform precisely and expertly each step of several procedures used in screening children for nutritional problems. It is intended for all health providers who are involved in weighing and measuring children, recording and plotting measurements on growth charts, taking blood samples to test for iron…

  8. First trimester contingent testing with either nuchal translucency or cell-free DNA. Cost efficiency and the role of ultrasound dating.

    PubMed

    Conner, Peter; Gustafsson, Sven; Kublickas, Marius

    2015-04-01

    To evaluate the performance and cost efficacy of different first-trimester contingent screening strategies based on an initial analysis of biochemical markers. Retrospective study. Swedish National Quality Register for prenatal diagnosis. 35,780 women with singleton pregnancies. Serum values from first trimester biochemistry were re-analyzed in a contingent approach. For risks between 1:40 and 1:1000, risk estimates from nuchal translucency measurements were added and outcomes were compared using either a final cut-off risk of 1:200 to proceed with invasive testing or offering non-invasive prenatal testing. In a subgroup of 12,836 women with regular menstrual cycles the same analyses were performed using data on the last menstrual period for determining gestational age. The costs of detecting one case of aneuploidy were compared. Comparison of screening strategies. The detection rate was the same (87%) in the contingent group as in complete combined screening, with only 41% requiring a nuchal translucency scan. As an alternative, offering non-invasive prenatal testing to the intermediate risk group would result in a detection rate of 98%, but the cost to detect one case of trisomy 21 would be 83% higher than the cost associated with traditional combined screening. First trimester examination using a contingent approach will achieve similar results compared with full combined screening. Non-invasive prenatal testing will not be cost-effective when a high proportion of pregnancies need further testing. © 2015 Nordic Federation of Societies of Obstetrics and Gynecology.

  9. Dipstick screening for urinary tract infection in febrile infants.

    PubMed

    Glissmeyer, Eric W; Korgenski, E Kent; Wilkes, Jacob; Schunk, Jeff E; Sheng, Xiaoming; Blaschke, Anne J; Byington, Carrie L

    2014-05-01

    This study compares the performance of urine dipstick alone with urine microscopy and with both tests combined as a screen for urinary tract infection (UTI) in febrile infants aged 1 to 90 days. We queried the Intermountain Healthcare data warehouse to identify febrile infants with urine dipstick, microscopy, and culture performed between 2004 and 2011. UTI was defined as >50 000 colony-forming units per milliliter of a urinary pathogen. We compared the performance of urine dipstick with unstained microscopy or both tests combined ("combined urinalysis") to identify UTI in infants aged 1 to 90 days. Of 13 030 febrile infants identified, 6394 (49%) had all tests performed and were included in the analysis. Of these, 770 (12%) had UTI. Urine culture results were positive within 24 hours in 83% of UTIs. The negative predictive value (NPV) was >98% for all tests. The combined urinalysis NPV was 99.2% (95% confidence interval: 99.1%-99.3%) and was significantly greater than the dipstick NPV of 98.7% (98.6%-98.8%). The dipstick positive predictive value was significantly greater than combined urinalysis (66.8% [66.2%-67.4%] vs 51.2% [50.6%-51.8%]). These data suggest 8 febrile infants would be predicted to have a false-positive combined urinalysis for every 1 infant with UTI initially missed by dipstick screening. Urine dipstick testing compares favorably with both microscopy and combined urinalysis in febrile infants aged 1 to 90 days. The urine dipstick test may be an adequate stand-alone screen for UTI in febrile infants while awaiting urine culture results. Copyright © 2014 by the American Academy of Pediatrics.

  10. Comparison of the clinical performances of the AdvanSure HPV Screening Real-Time PCR, the Abbott Real-Time High-Risk HPV Test, and the Hybrid Capture High-Risk HPV DNA Test for Cervical Cancer Screening.

    PubMed

    Chung, Hae-Sun; Hahm, Chorong; Lee, Miae

    2014-09-01

    The clinical performance of three human papillomavirus (HPV) DNA commercial assays for cervical cancer screening was evaluated; the AdvanSure HPV Screening Real-Time PCR (AdvanSure PCR; LG Life Sciences) that was developed recently for the detection of both high-risk and low-risk genotypes, the Abbott RealTime High-Risk HPV Test (Abbott PCR; Abbott Molecular) and the Hybrid Capture High-Risk HPV DNA test (HC2; Qiagen). The three different HPV DNA tests were compared using cytology samples obtained from 619 women who underwent routine cervical cancer screening. The gold-standard assay was histopathological confirmation of cervical intraepithelial neoplasia of grade 2 or worse. The clinical sensitivities of the AdvanSure PCR, the Abbott PCR and the HC2 for the detection of cervical intraepithelial neoplasia of grade 2 or worse were 95.5%, 95.5% and 100%, respectively, while the clinical specificities were 61.6%, 86.4% and 83.3%, respectively. There were no significant differences in the clinical sensitivities of the Abbott PCR and the AdvanSure PCR compared to the HC2. The clinical specificities of the Abbott PCR and the AdvanSure PCR for the detection of HPV types 16/18 were 97.8% and 98.5%, respectively. For cervical cancer screening, all three tests showed relatively good clinical sensitivities, but the AdvanSure PCR had lower clinical specificity than the Abbott PCR and the HC2. The AdvanSure PCR and the Abbott PCR assays have the advantage of being automated and the ability to distinguish between HPV types 16/18 and other HPV types. The two real-time PCR assays could be useful tools in HPV testing for cervical cancer screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. LOAD-ENHANCED MOVEMENT QUALITY SCREENING AND TACTICAL ATHLETICISM: AN EXTENSION OF EVIDENCE

    PubMed Central

    Schmitz, Randy J.; Rhea, Christopher K.; Ross, Scott E.

    2017-01-01

    Background Military organizations use movement quality screening for prediction of injury risk and performance potential. Currently, evidence of an association between movement quality and performance is limited. Recent work has demonstrated that external loading strengthens the relationship between movement screens and performance outcomes. Such loading may therefore steer us toward robust implementations of movement quality screens while maintaining their appeal as cost effective, field-expedient tools. Purpose The purpose of the current study was to quantify the effect of external load-bearing on the relationship between clinically rated movement quality and tactical performance outcomes while addressing the noted limitations. Study Design Crossover Trial. Methods Fifty young adults (25 male, 25 female, 22.98 ± 3.09 years, 171.95 ± 11.46 cm, 71.77 ± 14.03 kg) completed the Functional Movement Screen™ with (FMS™W) and without (FMS™C) a weight vest in randomized order. Following FMS™ testing, criterion measures of tactical performance were administered, including agility T-Tests, sprints, a 400-meter run, the Mobility for Battle (MOB) course, and a simulated casualty rescue. For each performance outcome, regression models were selected via group lasso with smoothed FMS™ item scores as candidate predictor variables. Results For all outcomes, proportion of variance accounted for was greater in FMS™W (R2 = ;0.22 [T-Test], 0.29 [Sprint], 0.17 [400 meter], 0.29 [MOB], and 0.11 [casualty rescue]) than in FMS™C (R2 = ;0.00 [T-Test], 0.11 [Sprint], 0.00 [400 meter], 0.19 [MOB], and 0.00 [casualty rescue]). From the FMS™W condition, beneficial performance effects (p<0.05) were observed for Deep Squat (sprint, casualty rescue), Hurdle Step (T-Agility, 400 meter run), Inline Lunge (sprint, MOB), and Trunk Stability Push Up (all models). Similar effects for FMS™C item scores were limited to Trunk Stability Push Up (p<0.05, all models). Conclusions The present study extends evidence supporting the validity of load-enhanced movement quality screening as a predictor of tactical performance ability. Future designs should seek to identify mechanisms explaining this effect. Level of Evidence 3 PMID:28593095

  12. LOAD-ENHANCED MOVEMENT QUALITY SCREENING AND TACTICAL ATHLETICISM: AN EXTENSION OF EVIDENCE.

    PubMed

    Glass, Stephen M; Schmitz, Randy J; Rhea, Christopher K; Ross, Scott E

    2017-06-01

    Military organizations use movement quality screening for prediction of injury risk and performance potential. Currently, evidence of an association between movement quality and performance is limited. Recent work has demonstrated that external loading strengthens the relationship between movement screens and performance outcomes. Such loading may therefore steer us toward robust implementations of movement quality screens while maintaining their appeal as cost effective, field-expedient tools. The purpose of the current study was to quantify the effect of external load-bearing on the relationship between clinically rated movement quality and tactical performance outcomes while addressing the noted limitations. Crossover Trial. Fifty young adults (25 male, 25 female, 22.98 ± 3.09 years, 171.95 ± 11.46 cm, 71.77 ± 14.03 kg) completed the Functional Movement Screen™ with (FMS™W) and without (FMS™C) a weight vest in randomized order. Following FMS™ testing, criterion measures of tactical performance were administered, including agility T-Tests, sprints, a 400-meter run, the Mobility for Battle (MOB) course, and a simulated casualty rescue. For each performance outcome, regression models were selected via group lasso with smoothed FMS™ item scores as candidate predictor variables. For all outcomes, proportion of variance accounted for was greater in FMS™W (R 2 = ;0.22 [T-Test], 0.29 [Sprint], 0.17 [400 meter], 0.29 [MOB], and 0.11 [casualty rescue]) than in FMS™C (R 2 = ;0.00 [T-Test], 0.11 [Sprint], 0.00 [400 meter], 0.19 [MOB], and 0.00 [casualty rescue]). From the FMS™W condition, beneficial performance effects (p<0.05) were observed for Deep Squat (sprint, casualty rescue), Hurdle Step (T-Agility, 400 meter run), Inline Lunge (sprint, MOB), and Trunk Stability Push Up (all models). Similar effects for FMS™C item scores were limited to Trunk Stability Push Up (p<0.05, all models). The present study extends evidence supporting the validity of load-enhanced movement quality screening as a predictor of tactical performance ability. Future designs should seek to identify mechanisms explaining this effect. 3.

  13. Computational fragment-based screening using RosettaLigand: the SAMPL3 challenge

    NASA Astrophysics Data System (ADS)

    Kumar, Ashutosh; Zhang, Kam Y. J.

    2012-05-01

    SAMPL3 fragment based virtual screening challenge provides a valuable opportunity for researchers to test their programs, methods and screening protocols in a blind testing environment. We participated in SAMPL3 challenge and evaluated our virtual fragment screening protocol, which involves RosettaLigand as the core component by screening a 500 fragments Maybridge library against bovine pancreatic trypsin. Our study reaffirmed that the real test for any virtual screening approach would be in a blind testing environment. The analyses presented in this paper also showed that virtual screening performance can be improved, if a set of known active compounds is available and parameters and methods that yield better enrichment are selected. Our study also highlighted that to achieve accurate orientation and conformation of ligands within a binding site, selecting an appropriate method to calculate partial charges is important. Another finding is that using multiple receptor ensembles in docking does not always yield better enrichment than individual receptors. On the basis of our results and retrospective analyses from SAMPL3 fragment screening challenge we anticipate that chances of success in a fragment screening process could be increased significantly with careful selection of receptor structures, protein flexibility, sufficient conformational sampling within binding pocket and accurate assignment of ligand and protein partial charges.

  14. Making the Case for Objective Performance Metrics in Newborn Screening by Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Rinaldo, Piero; Zafari, Saba; Tortorelli, Silvia; Matern, Dietrich

    2006-01-01

    The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the…

  15. Screening and prevention of neonatal glucose 6-phosphate dehydrogenase deficiency in Guangzhou, China.

    PubMed

    Jiang, J; Li, B; Cao, W; Jiang, X; Jia, X; Chen, Q; Wu, J

    2014-06-09

    We aimed to summarize the results of screening protocol and prevention of neonatal glucose 6-phosphate dehydrogenase (G6PD) deficiency during a 22-year-long period to provide a basis of reference for the screening of this disease. About 1,705,569 newborn subjects in Guangzhou City were screened for this deficiency. Specimens were collected according to the conventional method of specimen acquisition for "newborn dried bloodspot screening", preserved, and inspected. The specimens were studied with fluorescent spot test and quantitative fluorescence assay. Diagnosis was performed using the modified NBTG6PD/6PGD ratio method. Bloodspot filter paper specimens were sent to the laboratory within 24 h via EMS Express, and the G6PD test was performed on the same day. The G6PD deficiency-positive rate was 4.2% in the samples screened using the fluorescent spot test, while it was 5% in case of the quantitative fluorescence assay. Neonatal screening for G6PD deficiency for 11,437 cases (6117 boys and 5320 girls) showed positive results in 481 cases. About 420 cases (318 boys and 102 girls) of G6PD deficiency were confirmed with the modified Duchenne NBT ratio method. The total detection rate was 3.7:5.2% for boys and 1.9% for girls. Quantitative fluorescence assay improved the sensitivity and detection rate. Accelerating the speed of sample delivery by using Internet network systems and ensuring online availability of screening results can aid the screening and diagnosis of this deficiency within 1 week of birth.

  16. A Systematic Review on the Existing Screening Pathways for Lynch Syndrome Identification.

    PubMed

    Tognetto, Alessia; Michelazzo, Maria Benedetta; Calabró, Giovanna Elisa; Unim, Brigid; Di Marco, Marco; Ricciardi, Walter; Pastorino, Roberta; Boccia, Stefania

    2017-01-01

    Lynch syndrome (LS) is the most common hereditary colon cancer syndrome, accounting for 3-5% of colorectal cancer (CRC) cases, and it is associated with the development of other cancers. Early detection of individuals with LS is relevant, since they can take advantage of life-saving intensive care surveillance. The debate regarding the best screening policy, however, is far from being concluded. This prompted us to conduct a systematic review of the existing screening pathways for LS. We performed a systematic search of MEDLINE, ISI Web of Science, and SCOPUS online databases for the existing screening pathways for LS. The eligibility criteria for inclusion in this review required that the studies evaluated a structured and permanent screening pathway for the identification of LS carriers. The effectiveness of the pathways was analyzed in terms of LS detection rate. We identified five eligible studies. All the LS screening pathways started from CRC cases, of which three followed a universal screening approach. Concerning the laboratory procedures, the pathways used immunohistochemistry and/or microsatellite instability testing. If the responses of the tests indicated a risk for LS, the genetic counseling, performed by a geneticist or a genetic counselor, was mandatory to undergo DNA genetic testing. The overall LS detection rate ranged from 0 to 5.2%. This systematic review reported different existing pathways for the identification of LS patients. Although current clinical guidelines suggest to test all the CRC cases to identify LS cases, the actual implementation of pathways for LS identification has not been realized. Large-scale screening programs for LS have the potential to reduce morbidity and mortality for CRC, but coordinated efforts in educating all key stakeholders and addressing public needs are still required.

  17. Urine toxicology screening in an urban stroke and TIA population.

    PubMed

    Silver, Brian; Miller, Daniel; Jankowski, Michelle; Murshed, Nawaf; Garcia, Patricia; Penstone, Patricia; Straub, Melissa; Logan, Sean P; Sinha, Anita; Morris, Daniel C; Katramados, Angelos; Russman, Andrew N; Mitsias, Panayiotis D; Schultz, Lonni R

    2013-04-30

    We sought to determine the rate of urine toxicology screening, differences in testing, and outcomes among patients with stroke and TIA presenting to a tertiary care emergency department. In this retrospective cohort study, patients admitted with stroke or TIA to a single tertiary care stroke center between June 2005 and January 2007 were identified through a stroke database. Factors that predicted urine toxicology screening of patients and a positive test, and discharge outcomes of patients based on toxicology result were analyzed. Stroke severity, treatment with tissue plasminogen activator, discharge status, and stroke etiology were compared between toxicology positive and negative patients. A total of 1,024 patients were identified: 704 with ischemic stroke, 133 with intracerebral hemorrhage, and 205 with TIA. Urine toxicology screening was performed in 420 patients (40%); 11% of these studies were positive for cocaine (19% younger than 50 years and 9% 50 years or older). Factors that significantly predicted the performance of a urine toxicology screen were younger age (<50 years) and black race (<0.001). Positive toxicology screens occurred in a broad range of patients. There were no significant differences in admission NIH Stroke Scale score, stroke etiology, and discharge status between toxicology-positive and -negative patients. In this study, patients with stroke and TIA who were young and black were more likely to have urine toxicology screening. Eleven percent of all tested patients (and 9% of patients 50 years or older) were positive for cocaine. To avoid disparities, we suggest that all stroke and TIA patients be tested.

  18. The King-Devick test for sideline concussion screening in collegiate football.

    PubMed

    Leong, Danielle F; Balcer, Laura J; Galetta, Steven L; Evans, Greg; Gimre, Matthew; Watt, David

    2015-01-01

    Sports-related concussion has received increasing attention as a result of neurologic sequelae seen among athletes, highlighting the need for a validated, rapid screening tool. The King-Devick (K-D) test requires vision, eye movements, language function and attention in order to perform and has been proposed as a promising tool for assessment of concussion. We investigated the K-D test as a sideline screening tool in a collegiate cohort to determine the effect of concussion. Athletes (n=127, mean age 19.6±1.2 years) from the Wheaton College football and men's and women's basketball teams underwent baseline K-D testing at pre-season physicals for the 2012-2013 season. K-D testing was administered immediately on the sidelines for football players with suspected head injury during regular games and changes compared to baseline were determined. Post-season testing was also performed to compare non-concussed athletes' test performance. Concussed athletes (n=11) displayed sideline K-D scores that were significantly higher (worse) than baseline (36.5±5.6s vs. 31.3±4.5s, p<0.005, Wilcoxon signed-rank test). Post-season testing demonstrated improvement of scores and was consistent with known learning effects (35.1±5.2s vs. 34.4±5.0s, p<0.05, Wilcoxon signed-rank test). Test-retest reliability was analyzed between baseline and post-season administrations of the K-D test resulting in high levels of test-retest reliability (intraclass correlation coefficient (ICC)=0.95 [95% Confidence Interval 0.85-1.05]). The data show worsening of K-D test scores following concussion further supporting utility of the K-D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. Plasma Septin9 versus fecal immunochemical testing for colorectal cancer screening: a prospective multicenter study.

    PubMed

    Johnson, David A; Barclay, Robert L; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T

    2014-01-01

    Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9-80.9%) and 68.0% (95% CI 58.2-76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5-86.3%) compared with 97.4% (95% CI 94.1-98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% -95% CI 62.5-80.1%) was shown to be statistically non-inferior to FIT (68.0%-95% CI 58.2-76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. ClinicalTrials.gov NCT01580540.

  20. Cost-Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    PubMed

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2017-12-27

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared to the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon microsimulation model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess whether optimal screening strategies would change. Colonoscopy every 5 years, starting at age 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in population is not clear. Using a Microsimulation Screening Analysis-Colon microsimulation model, we found screening of patients with cystic fibrosis for CRC to be cost-effective. Due to the higher risk in these patients for CRC, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  1. Cost Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    PubMed

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2018-02-01

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared with the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess if optimal screening strategies would change. Colonoscopy every 5 years, starting at an age of 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in this population is not clear. Using a Microsimulation Screening Analysis-Colon model, we found screening of patients with cystic fibrosis for CRC to be cost effective. Because of the higher risk of CRC in these patients, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  2. Ethical, financial, and legal considerations to implementing emergency department HIV screening: a report from the 2007 conference of the National Emergency Department HIV Testing Consortium.

    PubMed

    Waxman, Michael J; Popick, Rachel S; Merchant, Roland C; Rothman, Richard E; Shahan, Judy B; Almond, Gregory

    2011-07-01

    We seek to identify and analyze, from a group of participants experienced with HIV screening, the perceived challenges and solutions to the ethical, financial, and legal considerations of emergency department (ED)-based HIV screening. We performed a qualitative analysis of the focus group discussions from the ethical, financial, and legal considerations portion of the inaugural National Emergency Department HIV Testing Consortium conference. Four groups composed of 20 to 25 consortium participants engaged in semistructured, facilitated focus group discussions. The focus group discussions were audiotaped and transcribed. A primary reader identified major themes and subthemes and representative quotes from the transcripts and summarized the discussions. Secondary and tertiary readers reviewed the themes, subthemes, and summaries for accuracy. The focus group discussions centered on the following themes. Ethical considerations included appropriateness of HIV screening in the ED and ethics of key elements of the 2006 Centers for Disease Control and Prevention HIV testing recommendations. Financial considerations included models of payment and support, role of health care insurance, financial ethics and downstream financial burdens, and advocacy approaches. Legal considerations included the adequacy of obtaining consent, partner notification, disclosure of HIV results, difficulties in addressing special populations, failure of not performing universal screening, failure to notify a person of being tested, failure to notify someone of their test results, liability of inaccurate tests, and failure to link to care. This qualitative analysis provides a broadly useful foundation to the ethical, financial, and legal considerations of implementing HIV screening programs in EDs throughout the United States. Copyright © 2011. Published by Mosby, Inc.

  3. Screening for gonorrhoea using samples collected through the English National Chlamydia Screening Programme and risk of false positives: a national survey of Local Authorities

    PubMed Central

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-01-01

    Objectives To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. Design and setting During May–July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15–24 years. Main outcome measures (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. Results 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450–4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17–67%. Conclusions Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. PMID:25324326

  4. Measurement of antinuclear antibodies and their fine specificities: time for a change in strategy?

    PubMed

    Otten, Henny G; Brummelhuis, Walter J; Fritsch-Stork, Ruth; Leavis, Helen L; Wisse, Bram W; van Laar, Jacob M; Derksen, Ronald H W M

    2017-01-01

    The current strategy for antinuclear antibody (ANA) analysis involves screening for presence with a subsequent detailed analysis of their specificity. The aim of this study is to compare the clinical and financial efficacy of this strategy between different commercial tests in a large cohort of unselected patients. In all consecutive 1030 patients associations were defined between results from different ANA test systems and the pre-test probability for connective tissue disease (CTDs). Test systems were used for screening (ANA-IIF vs. CTD screen) and definition of their fine specificity (profile 3 line blot vs. CTD single analytes). Positive ANA-IIF and/or CTD screen results were found in 304 sera. Further analysis for ANA-specificity by profile 3 line blot and CTD single analytes showed 86 discrepant results of which more than a third are clinically relevant, with the CTD single analyte assay performing better than the line blot in supporting or confirming the presence of a CTD. Autoantigens present in one test but absent in the other were of minor practical use. The ANA screening and identification strategies currently employed are not cost-effective as 83% of tests were performed in order to find specific autoantibodies in patients without the fitting clinical signs or symptoms. This causes many unexpected positive results and subsequent confusion with regard to interpretation. We advocate that some autoantigens should be excluded from the line blot and CTD assays and propose the use of a cost-effective and selective ANA specificity testing purely based on clinical guidance.

  5. A Performance Comparison of Color Vision Tests for Military Screening.

    PubMed

    Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A

    2016-04-01

    Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.

  6. Diffusion of digital breast tomosynthesis among women in primary care: associations with insurance type.

    PubMed

    Clark, Cheryl R; Tosteson, Tor D; Tosteson, Anna N A; Onega, Tracy; Weiss, Julie E; Harris, Kimberly A; Haas, Jennifer S

    2017-05-01

    Digital breast tomosynthesis (DBT) has shown potential to improve breast cancer screening and diagnosis compared to digital mammography (DM). The FDA approved DBT use in conjunction with conventional DM in 2011, but coverage was approved by CMS recently in 2015. Given changes in coverage policies, it is important to monitor diffusion of DBT by insurance type. This study examined DBT trends and estimated associations with insurance type. From June 2011 to September 2014, DBT use in 22 primary care centers in the Dartmouth -Brigham and Women's Hospital Population-based Research Optimizing Screening through Personalized Regimens research center (PROSPR) was examined among women aged 40-89. A longitudinal repeated measures analysis estimated the proportion of DBT performed for screening or diagnostic indications over time and by insurance type. During the study period, 93,182 mammograms were performed on 48,234 women. Of these exams, 16,506 DBT tests were performed for screening (18.1%) and 2537 were performed for diagnosis (15.7%). Between 2011 and 2014, DBT utilization increased in all insurance groups. However, by the latest observed period, screening DBT was used more frequently under private insurance (43.4%) than Medicaid (36.2%), Medicare (37.8%), other (38.6%), or no insurance (32.9%; P < 0.0001). No sustained differences in use of DBT for diagnostic testing were seen by insurance type. DBT is increasingly used for breast cancer screening and diagnosis. Use of screening DBT may be associated with insurance type. Surveillance is required to ensure that disparities in breast cancer screening are minimized as DBT becomes more widely available. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  7. Effectiveness of common fish screen materials for protecting lamprey ammocoetes—Influence of sweeping velocities and decreasing flows

    USGS Publications Warehouse

    Mesa, Matthew G.; Liedtke, Theresa L.; Weiland, Lisa K.; Christiansen, Helena E.

    2017-12-14

    In previous tests of the effectiveness of four common fish screen materials for excluding lamprey ammocoetes, we determined that woven wire (WW) allowed substantially more entrainment than perforated plate (PP), profile bar (PB), or Intralox (IL) material. These tests were simplistic because they used small vertically-oriented screens positioned perpendicular to the flow without a bypass or a sweeping velocity (SV). In the subsequent test discussed in this report, we exposed ammocoetes to much larger (2.5-m-wide) screen panels with flows up to 10 ft3 /s, a SV component, and a simulated bypass channel. The addition of a SV modestly improved protection of lamprey ammocoetes for all materials tested. A SV of 35 cm/s with an approach velocity (AV) of 12 cm/s, was able to provide protection for fish about 5–15 mm smaller than the protection provided by an AV of 12 cm/s without a SV component. The best-performing screen panels (PP, IL, and PB) provided nearly complete protection from entrainment for fish greater than 50-mm toal length, but the larger openings in the WW material only protected fish greater than 100-mm total length. Decreasing the AV and SV by 50 percent expanded the size range of protected lampreys by about 10–15 mm for those exposed to IL and WW screens, and it decreased the protective ability of PP screens by about 10 mm. Much of the improvement for IL and WW screens under the reduced flow conditions resulted from an increase in the number of lampreys swimming away from the screen. Fish of all sizes became impinged (that is, stuck on the screen surface for more than 1 s) on the screens, with the rate of impingement highest on PP (39– 72 percent) and lowest on WW (7–22 percent). Although impingements were common, injuries were rare, and 24-h post-test survival was greater than 99 percent. Our results refined the level of protection provided by these screen materials when both an AV and SV are present and confirmed our earlier recommendation that WW screens be replaced with more effective materials. Future work should focus on determining the risks associated with other screen types (for example, rotary drum screens, horizontal flat plate screens) and exploring the effectiveness of higher SV:AV ratios, because it may help expand the range of sizes protected by the best performing materials.

  8. Routine bacterial screening of apheresis platelets on Day 4 using a rapid test: a 4-year single-center experience.

    PubMed

    Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M

    2013-10-01

    The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.

  9. First trimester combined test for Down syndrome screening in unselected pregnancies - a report of a 13-year experience.

    PubMed

    Lee, Fa-Kung; Chen, Li-Ching; Cheong, Mei-Leng; Chou, Ching-Yu; Tsai, Ming-Song

    2013-12-01

    To analyze the performance of the first trimester Down syndrome screening in a single medical center in Northern Taiwan. From April 1999 to June 2012, a total of 25,104 pregnant women at gestational age of 10 weeks to 13 weeks 6 days received first trimester "combined test" for Down syndrome screening. The test combines the ultrasound scan of nuchal translucency thickness and maternal biochemical serum levels of pregnancy-associated plasma protein A (PAPP-A) and free beta-human chorionic gonadotropin (β-hCG). A positive screen was defined as an estimated Down syndrome risk ≥ 1/270, and either chorionic villous sampling or amniocentesis was performed for fetal chromosomal analyses. Seventy-eight of the 25,104 pregnancies were proven to have fetal chromosome anomalies. The detection rates for trisomy 21, trisomy 18, Turner syndrome, and other chromosome anomalies were 87.5% (21/24), 69.2% (9/13), 81.8% (9/11), and 60% (18/30), respectively, with a false positive rate (FPR) of 5.4% (1353/25,026). Further evaluation of the detection rates for trisomy 21, by gestational age at 11, 12, and 13 weeks, were 92.3%, 87.5%, and 66.7%, respectively. The first trimester combined test is an effective screening tool for Down syndrome detection with an acceptable low false positive rate. The best timing of screening will be between 11 and 12 weeks' gestation. Copyright © 2013. Published by Elsevier B.V.

  10. Antenatal screening for Down syndrome: a quantitative demonstration of the improvements over the past 20 years.

    PubMed

    Renshaw, Richard; Ellis, Katrina; Jacobs, Patricia; Morris, Joan

    2013-10-01

    Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a procedure-related risk of miscarriage. This study quantifies the improvement in the screening tests by calculating the number of women who had such tests per syndrome diagnosis from 1991 to 2010. Routinely stored data on prenatal chorionic villus sampling (CVS) and amniocentesis samples performed from 1991 to 2010 from the Wessex Regional Genetics Laboratory in England were extracted from the laboratory database. The numbers of diagnostic tests performed per Down, Edwards or Patau syndrome diagnosis were calculated according to the type of diagnostic test, and were adjusted for maternal age and gestational age at diagnosis. A total of 32,345 CVSs and amniocenteses identified 872 diagnoses of Down syndrome and 328 of Edwards and Patau syndrome. In 1991, there were 46 (95%CI: 16-111) CVSs per syndrome diagnosis compared with five (95%CI: 4-7) in 2010. For amniocenteses, the number fell from 53 (37-78) to 15 (11-22). This analysis demonstrates the improvements in antenatal screening for Down syndrome that have been made over the past 20 years, resulting in a reduction in the number of women tested and thus in the number of foetal deaths attributable to the testing procedure.

  11. Missed connections: Unintended consequences of updated cervical cancer screening guidelines on screening rates for sexually transmitted infections.

    PubMed

    Bogler, Tali; Farber, Allison; Stall, Nathan; Wijayasinghe, Sheila; Slater, Morgan; Guiang, Charlie; Glazier, Richard H

    2015-10-01

    To examine the effects of the updated 2012 cervical cancer screening guidelines on the rates of sexually transmitted infection (STI) screening in primary care. Retrospective chart review. Five academic family practice units at St Michael's Hospital in Toronto, Ont. Female patients, aged 19 to 25, who had at least 1 visit with a physician at 1 of the 5 academic family practice units during a 12-month period before (May 1, 2011, to April 30, 2012) or after (November 1, 2012, to October 31, 2013) the release of the updated guidelines. Number of women who received Papanicolaou tests or underwent STI screening; rates of STI screening performed during a Pap test or a periodic health examination; screening rates for HIV, syphilis, and hepatitis C; and the methods used for STI screening before and after the release of the updated guidelines. Results Before the release of the 2012 guidelines, 42 of 100 women had Pap tests and 40 of 100 women underwent STI screening. After the release of the guidelines, 17 of 100 women had Pap tests and 20 of 100 women received STI screening. Female patients were less likely to undergo STI screening under the 2012 guidelines compared with the 2005 guidelines (odds ratio 0.38, 95% CI 0.19 to 0.74; P = .003). Implementation of the 2012 cervical cancer screening guidelines was associated with lower rates of STI screening in the primary care setting. Primary care physicians should screen at-risk women for STIs at any clinically appropriate encounter and consider using noninvasive self-sampling methods.

  12. Fecal occult blood testing beliefs and practices of U.S. primary care physicians: serious deviations from evidence-based recommendations.

    PubMed

    Nadel, Marion R; Berkowitz, Zahava; Klabunde, Carrie N; Smith, Robert A; Coughlin, Steven S; White, Mary C

    2010-08-01

    Fecal occult blood testing (FOBT) is an important option for colorectal cancer screening that should be available in order to achieve high population screening coverage. However, results from a national survey of clinical practice in 1999-2000 indicated that many primary care physicians used inadequate methods to implement FOBT screening and follow-up. To determine whether methods to screen for fecal occult blood have improved, including the use of newer more sensitive stool tests. Cross-sectional national survey of primary care physicians. Participants consisted of 1,134 primary care physicians who reported ordering or performing FOBT in the 2006-2007 National Survey of Primary Care Physicians' Recommendations and Practices for Cancer Screening. Self-reported data on details of FOBT implementation and follow-up of positive results. Most physicians report using standard guaiac tests; higher sensitivity guaiac tests and immunochemical tests were reported by only 22.0% and 8.9%, respectively. In-office testing, that is, testing of a single specimen collected during a digital rectal examination in the office, is still widely used although inappropriate for screening: 24.9% of physicians report using only in-office tests and another 52.9% report using both in-office and home tests. Recommendations improved for follow-up after a positive test: fewer physicians recommend repeating the FOBT (17.8%) or using tests other than colonoscopy for the diagnostic work-up (6.6%). Only 44.3% of physicians who use home tests have reminder systems to ensure test completion and return. Many physicians continue to use inappropriate methods to screen for fecal occult blood. Intensified efforts to inform physicians of recommended technique and promote the use of tracking systems are needed.

  13. Effect of Touch Screen Tablet Use on Fine Motor Development of Young Children.

    PubMed

    Lin, Ling-Yi; Cherng, Rong-Ju; Chen, Yung-Jung

    2017-10-20

    To investigate the effects of touch-screen tablet use on the fine motor development of preschool children without developmental delay. 40 children who used a touch-screen tablet more 60 minutes per week for at least 1 month received a 24-week home fine motor activity program using a touch-screen-tablet. 40 children matched for age (mean = 61.0 months) and sex who did not meet the criteria for previous tablet use received a 24-week program consisting of manual play activities. Motor performance was measured using the Bruininks-Oseretsky Test of Motor Proficiency. The two-factor mixed design ANOVA was used to compare performance of the touch-screen tablet and non-touch-screen tablet groups. Pretest analysis showed no group differences in motor performance and pinch strength. At posttest, children in the nontouch-screen-tablet group made significantly greater changes in fine motor precision (p < 0.001), fine motor integration (p = 0.008), and manual dexterity (p = 0.003). Using a touch screen tablet extensively might be disadvantageous for the fine motor development of preschool children.

  14. Tier One Performance Screen Initial Operational Test and Evaluation: 2010 Annual Report

    DTIC Science & Technology

    2011-10-01

    ANNUAL REPORT EXECUTIVE SUMMARY Research Requirement: In addition to educational, physical , and moral screens, the U.S. Army relies on a...number of criteria of interest. Most notably, the Physical Conditioning scale predicted Soldiers’ self- reported Army Physical Fitness Test (APFT...individual Soldier through maximally effective selection, classification, and retention strategies. In addition to educational, physical , and moral

  15. Testing a Multi-Stage Screening System: Predicting Performance on Australia's National Achievement Test Using Teachers' Ratings of Academic and Social Behaviors

    ERIC Educational Resources Information Center

    Kettler, Ryan J.; Elliott, Stephen N.; Davies, Michael; Griffin, Patrick

    2012-01-01

    This study addresses the predictive validity of results from a screening system of academic enablers, with a sample of Australian elementary school students, when the criterion variable is end-of-year achievement. The investigation included (a) comparing the predictive validity of a brief criterion-referenced nomination system with more…

  16. High test positivity and low positive predictive value for colorectal cancer of continued faecal occult blood test screening after negative colonoscopy.

    PubMed

    Brown, Jeremy P; Wooldrage, Kate; Wright, Suzanne; Nickerson, Claire; Cross, Amanda J; Atkin, Wendy S

    2018-06-01

    Objectives The English Bowel Cancer Screening Programme offers biennial guaiac faecal occult blood test (gFOBT) screening to 60-74-year-olds. Participants with positive results are referred for follow-up, but many do not have significant findings. If they remain age eligible, these individuals are reinvited for gFOBT screening. We evaluated the performance of repeat screening in this group. Methods We analysed data on programme participants reinvited to gFOBT screening after either previous negative gFOBT ( n = 327,542), or positive gFOBT followed by a diagnostic investigation negative for colorectal cancer (CRC) or adenomas requiring surveillance ( n = 42,280). Outcomes calculated were uptake, test positivity, yield of CRC, and positive predictive value (PPV) of gFOBT for CRC. Results For participants with a previous negative gFOBT, uptake in the subsequent screening round was 87.5%, positivity was 1.3%, yield of CRC was 0.112% of those adequately screened, and the PPV of gFOBT for CRC was 9.1%. After a positive gFOBT and a negative diagnostic investigation, uptake in the repeat screening round was 82.6%, positivity was 11.3%, CRC yield was 0.172% of participants adequately screened, and the PPV of gFOBT for CRC was 1.7%. Conclusion With high positivity and low PPV for CRC, the suitability of routine repeat gFOBT screening in two years among individuals with a previous positive test and a negative diagnostic examination needs to be carefully considered.

  17. Colorectal Cancer Screening: Recommendations for Physicians and Patients from the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.

  18. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Taxonomy for colorectal cancer screening promotion: Lessons from recent randomized controlled trials.

    PubMed

    Ritvo, Paul; Myers, Ronald E; Serenity, Mardie; Gupta, Samir; Inadomi, John M; Green, Beverly B; Jerant, Anthony; Tinmouth, Jill; Paszat, Lawrence; Pirbaglou, Meysam; Rabeneck, Linda

    2017-08-01

    To derive a taxonomy for colorectal cancer screening that advances Randomized Controlled Trials (RCTs) and screening uptake. Detailed publication review, multiple interviews with principal investigators (PIs) and collaboration with PIs as co-authors produced a CRCS intervention taxonomy. Semi-structured interview questions with PIs (Drs. Inadomi, Myers, Green, Gupta, Jerant and Ritvo) yielded details about trial conduct. Interview comparisons led to an iterative process informing serial interviews until a consensus was obtained on final taxonomy structure. These taxonomy headings (Engagement Sponsor, Population Targeted, Alternative Screening Tests, Delivery Methods, and Support for Test Performance (EPADS)) were used to compare studies. Exemplary insights emphasized: 1) direct test delivery to patients; 2) linguistic-ethnic matching of staff to minority subjects; and 3) authorization of navigators to schedule or refer for colonoscopies and/or distribute stool blood tests during screening promotion. PIs of key RCTs (2012-2015) derived a CRCS taxonomy useful in detailed examination of CRCS promotion and design of future RCTs. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Effect of education and gender adjustment on the sensitivity and specificity of a cognitive screening battery for dementia: results from the MoVIES Project. Monongahela Valley Independent Elders Survey.

    PubMed

    Belle, S H; Seaberg, E C; Ganguli, M; Ratcliff, G; DeKosky, S; Kuller, L H

    1996-01-01

    The Monongahela Valley Independent Elders Survey (MoVIES) used a multiphase process to identify demented persons among 1,366 randomly selected noninstitutionalized individuals 65 years and older. Raw test scores from a cognitive screening battery were used to identify cognitively impaired individuals who were referred for a clinical evaluation. Subsequently, test scores were adjusted for education and gender within age strata. Adjusting test scores affected sensitivity for dementia only among the most educated, increasing sensitivity among younger subjects and decreasing among the older subjects. Specificity increased among the least educated and the oldest subjects. Overall, the adjusted criteria did not perform as well as the unadjusted criteria in this sample. Adjustment for education will not necessarily improve the ability of a screening battery for cognitive function to identify demented persons, particularly if unadjusted scores perform well.

  1. Capillary Liquid Acquisition Device Heat Entrapment

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L. G.; Hastings, L. J.; Statham, G.; Turpin, J. B.

    2007-01-01

    Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of subcooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs? Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, 200x1400 and 325x2300, both with Twill Dutch Weave. Upon consideration of both the water and LN2 data, it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.

  2. Human papillomavirus DNA testing as an adjunct to cytology in cervical screening programs.

    PubMed

    Lörincz, Attila T; Richart, Ralph M

    2003-08-01

    Our objective was to review current large studies of human papillomavirus (HPV) DNA testing as an adjunct to the Papanicolaou test for cervical cancer screening programs. We analyzed 10 large screening studies that used the Hybrid Capture 2 test and 3 studies that used the polymerase chain reaction test in a manner that enabled reliable estimates of accuracy for detecting or predicting high-grade cervical intraepithelial neoplasia (CIN). Most studies allowed comparison of HPV DNA and Papanicolaou testing and estimates of the performance of Papanicolaou and HPV DNA as combined tests. The studies were selected on the basis of a sufficient number of cases of high-grade CIN and cancer to provide meaningful statistical values. Investigators had to demonstrate the ability to generate reasonably reliable Hybrid Capture 2 or polymerase chain reaction data that were either minimally biased by nature of study design or that permitted analytical techniques for addressing issues of study bias to be applied. Studies had to provide data for the calculation of test sensitivity, specificity, predictive values, odds ratios, relative risks, confidence intervals, and other relevant measures. Final data were abstracted directly from published articles or estimated from descriptive statistics presented in the articles. In some studies, new analyses were performed from raw data supplied by the principal investigators. We concluded that HPV DNA testing was a more sensitive indicator for prevalent high-grade CIN than either conventional or liquid cytology. A combination of HPV DNA and Papanicolaou testing had almost 100% sensitivity and negative predictive value. The specificity of the combined tests was slightly lower than the specificity of the Papanicolaou test alone, but this decrease could potentially be offset by greater protection from neoplastic progression and cost savings available from extended screening intervals. One "double-negative" HPV DNA and Papanicolaou test indicated better prognostic assurance against risk of future CIN 3 than 3 subsequent negative conventional Papanicolaou tests and may safely allow 3-year screening intervals for such low-risk women.

  3. “Targeted” Screening for Cytomegalovirus (CMV)-Related Hearing Loss: It’s Time for Universal CMV Screening in the NICU!

    PubMed Central

    Medoro, Alexandra; Malhotra, Prashant; Shimamura, Masako; Hounam, Gina; Findlen, Ursula; Wozniak, Phillip; Foor, Nicholas; Adunka, Oliver; Sanchez, Pablo J

    2017-01-01

    Abstract Background Congenital CMV infection is the leading cause of non-genetic sensorineural hearing loss in infancy. Antiviral therapy has been shown to improve hearing outcomes, and thus “targeted” CMV screening for newborns who do not pass the hearing screen has been recommended. Diagnosis of congenital CMV infection requires that the infant be tested for CMV in the first 3 weeks of age. Our objective was to determine when infants in the neonatal intensive care unit (NICU) have their first hearing screen performed and thus inform the practice of targeted screening for determination of CMV-related hearing loss. Methods Retrospective review of the electronic health records of all infants admitted to the Level 4 outborn NICU at Nationwide Children’s Hospital, Columbus, OH from August 2016 to May 2017. Demographic and clinical data were obtained, and the age that the first hearing screen was performed was assessed. Results During the 10 month study period, 362 infants were admitted to the NICU and had a first hearing screen performed. The majority of neonates (204, 56%) had a first hearing screen performed in the first 3 weeks of age. However, 158 (44%; median birth weight [IQR], 1072 g [747–1766]; median gestational age [IQR], 28 weeks [25–32]) infants received the first hearing screen at >3 weeks of age when a positive CMV PCR or culture cannot distinguish congenital infection from intrapartum/postnatal acquisition of CMV. Of the 158 infants, 20 (13%) did not pass the first hearing screen (13, unilateral; 7, bilateral), and subsequently, 9 of them did pass a second hearing screen. However, 11 of the 20 infants did not pass a second hearing screen and had urine CMV PCR testing, and 1 (9%) was positive. This latter infant’s newborn dried blood spot CMV DNA PCR was negative so a diagnosis of congenital CMV infection was not possible. Conclusion Targeted screening in the NICU for CMV-related hearing loss is problematic as a substantial number of infants do not have a hearing screen performed until after 21 days of age, thus representing a missed opportunity for diagnosis of congenital CMV infection and institution of antiviral therapy if indicated. Our findings support universal CMV screening of neonates on admission to the NICU. Disclosures O. Adunka, MED-EL Corporation: Consultant, Consulting fee, Educational grant and Research support; Advanced Bionics: Consultant, Consulting fee and Licensing agreement or royalty; Advanced Cochlear Diagnostics: President, Ownership interest; AGTC Corporation: Consultant, Consulting fee

  4. Hepatitis B transmission by cell and tissue allografts: How safe is safe enough?

    PubMed Central

    Solves, Pilar; Mirabet, Vicente; Alvarez, Manuel

    2014-01-01

    More than 2 million human tissue transplants (bone, tendon, cartilage, skin, cornea, amniotic membrane, stem cells, heart valve, blood vessel, etc.), are performed worldwide every year. Cells and tissues are shared between countries which have different regulations and laboratory equipment and represent a risk of hepatitis B virus (HBV) transmission that has become a global safety concern. While the risk of transfusion-transmitted HBV infection from blood donations has been estimated, the rate of HBV transmission from donors to recipients of allografts is unknown and varies between different tissues. There are various important ways of reducing the transmission risk, but donor screening and donor testing are still the main factors for preventing HBV transmission. HBV detection is included in the routine screening tests for cell and tissue donors. The standard test for preventing transplant-transmitted hepatitis B is the hepatitis B surface antigen. The implementation of methods involving nucleic acid amplification and the new generation of reactives to detect viral antibodies or antigens with an immunoassay, has increased the sensitivity and the specificity of the screening tests. The objective of our research was to review the literature and critically analyse the different steps for avoiding HBV transmission in cell and tissue donors, focusing on the screening tests performed. PMID:24966613

  5. Screening for Colorectal Cancer: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Bibbins-Domingo, Kirsten; Grossman, David C; Curry, Susan J; Davidson, Karina W; Epling, John W; García, Francisco A R; Gillman, Matthew W; Harper, Diane M; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Owens, Douglas K; Phillips, William R; Phipps, Maureen G; Pignone, Michael P; Siu, Albert L

    2016-06-21

    Colorectal cancer is the second leading cause of cancer death in the United States. In 2016, an estimated 134,000 persons will be diagnosed with the disease, and about 49,000 will die from it. Colorectal cancer is most frequently diagnosed among adults aged 65 to 74 years; the median age at death from colorectal cancer is 68 years. To update the 2008 US Preventive Services Task Force (USPSTF) recommendation on screening for colorectal cancer. The USPSTF reviewed the evidence on the effectiveness of screening with colonoscopy, flexible sigmoidoscopy, computed tomography colonography, the guaiac-based fecal occult blood test, the fecal immunochemical test, the multitargeted stool DNA test, and the methylated SEPT9 DNA test in reducing the incidence of and mortality from colorectal cancer or all-cause mortality; the harms of these screening tests; and the test performance characteristics of these tests for detecting adenomatous polyps, advanced adenomas based on size, or both, as well as colorectal cancer. The USPSTF also commissioned a comparative modeling study to provide information on optimal starting and stopping ages and screening intervals across the different available screening methods. The USPSTF concludes with high certainty that screening for colorectal cancer in average-risk, asymptomatic adults aged 50 to 75 years is of substantial net benefit. Multiple screening strategies are available to choose from, with different levels of evidence to support their effectiveness, as well as unique advantages and limitations, although there are no empirical data to demonstrate that any of the reviewed strategies provide a greater net benefit. Screening for colorectal cancer is a substantially underused preventive health strategy in the United States. The USPSTF recommends screening for colorectal cancer starting at age 50 years and continuing until age 75 years (A recommendation). The decision to screen for colorectal cancer in adults aged 76 to 85 years should be an individual one, taking into account the patient's overall health and prior screening history (C recommendation).

  6. Using screen-based simulation to improve performance during pediatric resuscitation.

    PubMed

    Biese, Kevin J; Moro-Sutherland, Donna; Furberg, Robert D; Downing, Brian; Glickman, Larry; Murphy, Alison; Jackson, Cheryl L; Snyder, Graham; Hobgood, Cherri

    2009-12-01

    To assess the ability of a screen-based simulation-training program to improve emergency medicine and pediatric resident performance in critical pediatric resuscitation knowledge, confidence, and skills. A pre-post, interventional design was used. Three measures of performance were created and assessed before and after intervention: a written pre-course knowledge examination, a self-efficacy confidence score, and a skills-based high-fidelity simulation code scenario. For the high-fidelity skills assessment, independent physician raters recorded and reviewed subject performance. The intervention consisted of eight screen-based pediatric resuscitation scenarios that subjects had 4 weeks to complete. Upon completion of the scenarios, all three measures were repeated. For the confidence assessment, summary pre- and post-test summary confidence scores were compared using a t-test, and for the skills assessment, pre-scores were compared with post-test measures for each individual using McNemar's chi-square test for paired samples. Twenty-six of 35 (71.3%) enrolled subjects completed the institutional review board-approved study. Increases were observed in written test scores, confidence, and some critical interventions in high-fidelity simulation. The mean improvement in cumulative confidence scores for all residents was 10.1 (SD +/-4.9; range 0-19; p < 0.001), with no resident feeling less confident after the intervention. Although overall performance in simulated codes did not change significantly, with average scores of 6.65 (+/-1.76) to 7.04 (+/-1.37) out of 9 possible points (p = 0.58), improvement was seen in the administering of appropriate amounts of IV fluids (59-89%, p = 0.03). In this study, improvements in resident knowledge, confidence, and performance of certain skills in simulated pediatric cardiac arrest scenarios suggest that screen-based simulations may be an effective way to enhance resuscitation skills of pediatric providers. These results should be confirmed using a randomized design with an appropriate control group. (c) 2009 by the Society for Academic Emergency Medicine.

  7. Validity of clinical color vision tests for air traffic control specialists.

    DOT National Transportation Integrated Search

    1992-10-01

    An experiment on the relationship between aeromedical color vision screening test performance and performance on color-dependent tasks of Air Traffic Control Specialists was replicated to expand the data base supporting the job-related validity of th...

  8. Fasting glycaemia to simplify screening for gestational diabetes.

    PubMed

    Ryser Rüetschi, J; Jornayvaz, F R; Rivest, R; Huhn, E A; Irion, O; Boulvain, M

    2016-12-01

    Recommendations in Switzerland on screening for gestational diabetes endorse the International Association of Diabetes in Pregnancy Study Group consensus. As universal testing is time consuming and glucose loading is unpleasant, the recommendations include a simplification, not performing the glucose loading in women with fasting glycaemia <4.4 mmol/l. Our objective was to evaluate the diagnostic performance of this simplified strategy, compared with the complete test, in our population with a low prevalence of gestational diabetes. We collected 2298 complete 75-g glucose tolerance tests. We simulated stopping the test, so avoiding the glucose loading and further glycaemia, if fasting glycaemia was <4.4 or ≥5.1 mmol/l. Unselected pregnant women from Geneva and Basel, at 24-28 weeks of gestation. We calculated the sensitivity, and the percentage of women who would avoid the complete test with the strategy based on fasting glycaemia. The prevalence of gestational diabetes was 10.9% in our population. Among 251 women with gestational diabetes, fasting glycaemia was ≥5.1 mmol/l in 119 women (47.4%), between 4.4 and <5.1 mmol/l in 78 women (31.1%) and <4.4 mmol/l in 54 women (21.5%). Proceeding with the complete test only in women with fasting glycaemia between 4.4 and <5.1 mmol/l will result in a sensitivity of 78.5%. This strategy would avoid glucose loading in 63.8% of women. Screening with fasting glycaemia is an attractive alternative to universal screening with the complete 75-g glucose tolerance test. This strategy is, however, slightly less sensitive than previously reported in higher-risk populations. Fasting glycaemia can be considered as an alternative to the complete test for gestational diabetes screening. © 2016 Royal College of Obstetricians and Gynaecologists.

  9. Real-Time Monitoring of Results During First Year of Dutch Colorectal Cancer Screening Program and Optimization by Altering Fecal Immunochemical Test Cut-Off Levels.

    PubMed

    Toes-Zoutendijk, Esther; van Leerdam, Monique E; Dekker, Evelien; van Hees, Frank; Penning, Corine; Nagtegaal, Iris; van der Meulen, Miriam P; van Vuuren, Anneke J; Kuipers, Ernst J; Bonfrer, Johannes M G; Biermann, Katharina; Thomeer, Maarten G J; van Veldhuizen, Harriët; Kroep, Sonja; van Ballegooijen, Marjolein; Meijer, Gerrit A; de Koning, Harry J; Spaander, Manon C W; Lansdorp-Vogelaar, Iris

    2017-03-01

    After careful pilot studies and planning, the national screening program for colorectal cancer (CRC), with biennial fecal immunochemical tests (FITs), was initiated in The Netherlands in 2014. A national information system for real-time monitoring was developed to allow for timely evaluation. Data were collected from the first year of this screening program to determine the importance of planning and monitoring for optimal screening program performance. The national information system of the CRC screening program kept track of the number of invitations sent in 2014, FIT kits returned, and colonoscopies performed. Age-adjusted rates of participation, the number of positive test results, and positive predictive values (PPVs) for advanced neoplasia were determined weekly, quarterly, and yearly. In 2014, there were 741,914 persons invited for FIT; of these, 529,056 (71.3%; 95% CI, 71.2%-71.4%) participated. A few months into the program, real-time monitoring showed that rates of participation and positive test results (10.6%; 95% CI, 10.5%-10.8%) were higher than predicted and the PPV was lower (42.1%; 95% CI, 41.3%-42.9%) than predicted based on pilot studies. To reduce the burden of unnecessary colonoscopies and alleviate colonoscopy capacity, the cut-off level for a positive FIT result was increased from 15 to 47 μg Hb/g feces halfway through 2014. This adjustment decreased the percentage of positive test results to 6.7% (95% CI, 6.6%-6.8%) and increased the PPV to 49.1% (95% CI, 48.3%-49.9%). In total, the first year of the Dutch screening program resulted in the detection of 2483 cancers and 12,030 advanced adenomas. Close monitoring of the implementation of the Dutch national CRC screening program allowed for instant adjustment of the FIT cut-off levels to optimize program performance. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Composition of a Vision Screen for Servicemembers With Traumatic Brain Injury: Consensus Using a Modified Nominal Group Technique

    PubMed Central

    Finkelstein, Marsha; Llanos, Imelda; Scheiman, Mitchell; Wagener, Sharon Gowdy

    2014-01-01

    Vision impairment is common in the first year after traumatic brain injury (TBI), including among service members whose brain injuries occurred during deployment in Iraq and Afghanistan. Occupational therapy practitioners provide routine vision screening to inform treatment planning and referral to vision specialists, but existing methods are lacking because many tests were developed for children and do not screen for vision dysfunction typical of TBI. An expert panel was charged with specifying the composition of a vision screening protocol for servicemembers with TBI. A modified nominal group technique fostered discussion and objective determinations of consensus. After considering 29 vision tests, the panel recommended a nine-test vision screening that examines functional performance, self-reported problems, far–near acuity, reading, accommodation, convergence, eye alignment and binocular vision, saccades, pursuits, and visual fields. Research is needed to develop reliable, valid, and clinically feasible vision screening protocols to identify TBI-related vision disorders in adults. PMID:25005505

  11. Predictive validity of the UKCAT for medical school undergraduate performance: a national prospective cohort study.

    PubMed

    Tiffin, Paul A; Mwandigha, Lazaro M; Paton, Lewis W; Hesselgreaves, H; McLachlan, John C; Finn, Gabrielle M; Kasim, Adetayo S

    2016-09-26

    The UK Clinical Aptitude Test (UKCAT) has been shown to have a modest but statistically significant ability to predict aspects of academic performance throughout medical school. Previously, this ability has been shown to be incremental to conventional measures of educational performance for the first year of medical school. This study evaluates whether this predictive ability extends throughout the whole of undergraduate medical study and explores the potential impact of using the test as a selection screening tool. This was an observational prospective study, linking UKCAT scores, prior educational attainment and sociodemographic variables with subsequent academic outcomes during the 5 years of UK medical undergraduate training. The participants were 6812 entrants to UK medical schools in 2007-8 using the UKCAT. The main outcome was academic performance at each year of medical school. A receiver operating characteristic (ROC) curve analysis was also conducted, treating the UKCAT as a screening test for a negative academic outcome (failing at least 1 year at first attempt). All four of the UKCAT scale scores significantly predicted performance in theory- and skills-based exams. After adjustment for prior educational achievement, the UKCAT scale scores remained significantly predictive for most years. Findings from the ROC analysis suggested that, if used as a sole screening test, with the mean applicant UKCAT score as the cut-off, the test could be used to reject candidates at high risk of failing at least 1 year at first attempt. However, the 'number needed to reject' value would be high (at 1.18), with roughly one candidate who would have been likely to pass all years at first sitting being rejected for every higher risk candidate potentially declined entry on this basis. The UKCAT scores demonstrate a statistically significant but modest degree of incremental predictive validity throughout undergraduate training. Whilst the UKCAT could be considered a fairly crude screening tool for future academic performance, it may offer added value when used in conjunction with other selection measures. Future work should focus on the optimum role of such tests within the selection process and the prediction of post-graduate performance.

  12. [Reference values for the blood coagulation tests in Mexico: usefulness of the pooled plasma from blood donors].

    PubMed

    Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham

    2012-01-01

    The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.

  13. Evaluation of the GADD45α-GFP GreenScreen HC assay for rapid and reliable in vitro early genotoxicity screening.

    PubMed

    Luzy, Anne-Pascale; Orsini, Nicolas; Linget, Jean-Michel; Bouvier, Guy

    2013-11-01

    Twenty-two of Galderma's proprietary compounds were tested in the GADD45α-GFP 'GreenScreen HC' assay (GS), the SOS-ChromoTest and the Mini-Ames to evaluate GSs performance for early genotoxicity screening purposes. Forty more characterized compounds were also tested, including antibiotics: metronidazole, clindamycin, tetracycline, lymecycline and neomycin; and catecholamines: resorcinol mequinol, hydroquinone, one aneugen carbendazim, one corticoid dexamethasone, one peroxisome proliferator-activated receptor rosiglitazone, one pesticide carbaryl and two further proprietary molecules with in vitro genotoxicity data. With proprietary molecules, this study concluded that the GS renders the SOS-ChromoTest obsolete for in vitro screening. The GS confirmed all results of the Mini-Ames test (100% concordance). Compared with the micronucleus test, the GS showed a concordance of 82%. With known compounds, the GS ranked the potency of positive results for catecholamines in accordance with other genotoxicity tests and showed very reproducible results. It confirmed positive results for carbendazim, for tetracycline antibiotics and for carbaryl. The GS produced negative results for metronidazole, a nitroreduction-specific bacterial mutagen, for dexamethasone (a non-genotoxic apoptosis inducer), for rosiglitazone (a GADD45γ promoter inducer) and for clindamycin and neomycin (inhibitors of macromolecular synthesis in bacteria). As such, the GS appears to be a reproducible, robust, specific and sensitive test for genotoxicity screening. Copyright © 2012 John Wiley & Sons, Ltd.

  14. Comparison of immunohistochemistry and polymerase chain reaction for detection of West Nile virus in naturally infected dead birds.

    PubMed

    Sandhu, Tejbir; Sidhu, Dalbinder; Dhillon, Major; Fang, Ying

    2010-10-04

    Credible vector-borne disease surveillance programs, especially in developing countries with limited resources, must include diagnostic tests that are efficient, inexpensive and simple and safe to administer while maintaining high levels of sensitivity and specificity. Since immunohistochemistry (IHC) includes most of these features, its sensitivity, specificity, predictive positive value (PPV) and predictive negative value (PNV) for West Nile virus (WNv) screening were compared to those of the gold standard, RT-PCR testing of kidney tissue in dead birds. IHC and RT-PCR were performed for WNv antigen on 41 dead birds (belonging to five orders) collected from the northwest region of the Riverside County of California. Fixed tissue sections were screened by IHC using polyclonal antibodies, and frozen kidney tissues were tested with RT-PCR. Kidney screening with IHC showed sensitivity, specificity, PPV and NPV of 95.45%, 73.68%, 80.77% and 93.33%, respectively. Based on WNv screening of kidney tissue, IHC and RT-PCR were in agreement with 95.45% (21/22) for positive dead birds and were in 100% (22/22) agreement when multi-organ screening by IHC was performed. The present study showed that IHC is as equally effective as RT-PCR in screening for WNv in dead birds. Therefore, IHC can effectively serve as a competent screening technique for those disease surveillance agencies that lack expensive RT-PCR technology while promoting safer biohazardous conditions, except at the initial stage of tissue collection.

  15. Cross-validation of a dementia screening test in a heterogeneous population.

    PubMed

    Ritchie, K A; Hallerman, E F

    1989-09-01

    Recognition of the increasing importance of early dementia screening for both research and clinical purposes has led to the development of numerous screening instruments. The most promising of these are based on neuropsychological measures which are able to focus on very specific cognitive functions. Of these tests the Iowa screening test is of particular interest to researchers and clinicians working with heterogenous populations or wishing to make cross-cultural comparisons as it is relatively culture-fair and does not assume literacy. A preliminary study of the performance of the Iowa in an Israeli sample of diverse ethnic origins and low education level suggests it to be a very sensitive measure even in such groups. The study also demonstrates the inadvisability of adopting item weights derived by multivariate statistical techniques from another population.

  16. Prostate-Specific Antigen (PSA)–Based Population Screening for Prostate Cancer: An Economic Analysis

    PubMed Central

    Tawfik, A

    2015-01-01

    Background The prostate-specific antigen (PSA) blood test has become widely used in Canada to test for prostate cancer (PC), the most common cancer among Canadian men. Data suggest that population-based PSA screening may not improve overall survival. Objectives This analysis aimed to review existing economic evaluations of population-based PSA screening, determine current spending on opportunistic PSA screening in Ontario, and estimate the cost of introducing a population-based PSA screening program in the province. Methods A systematic literature search was performed to identify economic evaluations of population-based PSA screening strategies published from 1998 to 2013. Studies were assessed for their methodological quality and applicability to the Ontario setting. An original cost analysis was also performed, using data from Ontario administrative sources and from the published literature. One-year costs were estimated for 4 strategies: no screening, current (opportunistic) screening of men aged 40 years and older, current (opportunistic) screening of men aged 50 to 74 years, and population-based screening of men aged 50 to 74 years. The analysis was conducted from the payer perspective. Results The literature review demonstrated that, overall, population-based PSA screening is costly and cost-ineffective but may be cost-effective in specific populations. Only 1 Canadian study, published 15 years ago, was identified. Approximately $119.2 million is being spent annually on PSA screening of men aged 40 years and older in Ontario, including close to $22 million to screen men younger than 50 and older than 74 years of age (i.e., outside the target age range for a population-based program). A population-based screening program in Ontario would cost approximately $149.4 million in the first year. Limitations Estimates were based on the synthesis of data from a variety of sources, requiring several assumptions and causing uncertainty in the results. For example, where Ontario-specific data were unavailable, data from the United States were used. Conclusions PSA screening is associated with significant costs to the health care system when the cost of the PSA test itself is considered in addition to the costs of diagnosis, staging, and treatment of screen-detected PCs. PMID:26366237

  17. Organized colorectal cancer screening in Serbia - the first round within 2013-2014.

    PubMed

    Banković Lazarević, Dušica; Krivokapić, Zoran; Barišić, Goran; Jovanović, Verica; Ilić, Dragan; Veljković, Marko

    2016-04-01

    The National Organized Colorectal Cancer Screening Program was conducted in the Republic of Serbia during 2013-2014 covering the population of both genders, aged 50 to 74 years, in 28 municipalities out of 180, with the target population of 651,445 people. This organized colorectal cancer screening aims to reduce mortality from colorectal cancer in the target population. The aim of this study was to show the results of organized screening for colorectal cancer during the first biannual round in Serbia. General practitioners from the primary health centers, invited target population by letters and by phone to perform immunochemical fecal occult blood test. Persons with a positive test results were referred to the colonoscopy. The database of health insurance and other citizens of the target population was used for invitation for screening in primary health centers. Descriptive statistical analysis of the results in organized colorectal cancer screening in the first round was performed for the key screening indicators. In the first round, a total of 99,592 persons were invited. The participation rate was 62.5%. Colonoscopy was performed in 1,554 persons. Adenomas were found in 586 persons (0.9% of all the tested), e.g. 37.7 % of all colonoscopied. In 129 persons colorectal cancer was diagnosed (0.2% of all the tested), e.g. 8.3% of all the colonoscopied. In the left half of the colon (rectum, sigmoid and descending colon) there were 70.4% diagnosed polyps and 77.3% carcinomas, while 29.6% of polyps and 22.7% carcinomas were found in the proximal parts of the colon. In the first round of the organized colorectal cancer screening in Serbia the participation rate of the targeted population was high and gave encouraging result. It was expected that in the forthcoming rounds even higher coverage of the target population would be accomplished. A positive predictive value of the completed colonoscopies showed that further work on observing the stages of diagnosed adenomas and carcinomas would reach the goals of the expected improvement in early detection of colorectal cancer in Serbia.

  18. [Multiplex Ligation - dependent Probe Amplification (MLPA) as a screening test in children with developmental defects and intellectual disability of unknown etiology].

    PubMed

    Laczmańska, Izabela; Jakubiak, Aleksandra; Slęzak, Ryszard; Pesz, Karolina; Stembalska, Agnieszka; Laczmański, Lukasz; Sąsiadek, Maria M; Smigiel, Robert

    2011-01-01

    Developmental delay and intellectual disability are significant medical and social problems which concern 1-3% of population. The etiology remains unknown in over half of the cases. To evaluate the efficiency of MLPA (Multiplex Ligation-dependent Probe Amplification) as a screening test in diagnosis of patients with developmental delay and/or intellectual disability. 313 MLPA tests were performed in 256 patients with developmental delay and/ or intellectual disability with unknown etiology. MLPA test was made after exclusion of genetic disorders possible to diagnose by dysmorphological examination or using specifi c genetic tests. Positive results were confirmed by FISH analysis with appropriate probes. Chromosomal microaberrations were identifi ed in 15 patients (4,8%): deletions of 1p36 in 4 cases, in one case deletion of 22q11.21, 22q13.33, SNRPN1, 4ptel, 6qtel, 7q11.23, 16ptel, 18qtel as well as one ca se of deletion 3ptel/duplication 15qtel; deletion 18qtel/duplication Xqtel, and also duplication 7q11.23. Detail clinical analysis was performed in patients with diagnosed microaberrations in MLPA test. The molecular MLPA test, screening for chromosomal microaberration syndromes, should be performed in each patient with developmental delay and/or intellectual disability of unknown etiology and normal cytogenetic analysis, even if congenital defects and positive familial history do not exist.

  19. When does mass screening for open neural tube defects in low-risk pregnancies result in cost savings?

    PubMed Central

    Tosi, L L; Detsky, A S; Roye, D P; Morden, M L

    1987-01-01

    Using a decision analysis model, we estimated the savings that might be derived from a mass prenatal screening program aimed at detecting open neural tube defects (NTDs) in low-risk pregnancies. Our baseline analysis showed that screening v. no screening could be expected to save approximately $8 per pregnancy given a cost of $7.50 for the maternal serum alpha-feto-protein (MSAFP) test and a cost of $42,507 for hospital and rehabilitation services for the first 10 years of life for a child with spina bifida. When a more liberal estimate of the costs of caring for such a child was used, the savings with the screening program were more substantial. We performed extensive sensitivity analyses, which showed that the savings were somewhat sensitive to the cost of the MSAFP test and highly sensitive to the specificity (but not the sensitivity) of the test. A screening program for NTDs in low-risk pregnancies may result in substantial savings in direct health care costs if the screening protocol is followed rigorously and efficiently. PMID:2433011

  20. Can the Platelet Function Analyzer (PFA)-100 test substitute for the template bleeding time in routine clinical practice?

    PubMed

    Francis, J; Francis, D; Larson, L; Helms, E; Garcia, M

    1999-01-01

    The bleeding time (BT) is widely used in clinical medicine as a screening test of platelet function, although its deficiencies in such a role are well recognized. The Platelet Function Analyzer (PFA)-100 measures the ability of platelets activated in a high-shear environment to occlude an aperture in a membrane treated with collagen and epinephrine (CEPI) or collagen and ADP (CADP). The time taken for flow across the membrane to stop (closure time) is recorded. This study compared the PFA-100 with the BT as a screening test of platelet dysfunction in 113 hospital inpatients. The PFA-100 test was performed initially using the CEPI cartridge; CADP tests were performed on those with abnormal (> 163 s) CEPI closure times. Whole blood platelet aggregation studies and chart review were performed on patients in whom the BT and PFA-100 results did not agree.Abnormal bleeding times and PFA-100 results were obtained in 20.4% and 35.4% of patients, respectively. The results of BT and PFA-100 agreed in 74.3% of patients. Of the 29 patients in whom the BT and PFA-100 results were discordant, whole blood platelet aggregation studies supported the PFA-100 result in 25 (86.2%). The PFA-100 was more sensitive to aspirin-induced platelet dysfunction and was more rapidly and cheaply performed than the BT. Since the PFA-100 test reflects platelet function better than the BT, we conclude that this test could replace the BT as a first-line screening test for platelet dysfunction in clinical practice.

  1. Patient perceptions of stool DNA testing for pan-digestive cancer screening: A survey questionnaire

    PubMed Central

    Yang, Dennis; Hillman, Shauna L; Harris, Ann M; Sinicrope, Pamela S; Devens, Mary E; Ahlquist, David A

    2014-01-01

    AIM: To explore patient interest in a potential multi-organ stool-DNA test (MUST) for pan-digestive cancer screening. METHODS: A questionnaire was designed and mailed to 1200 randomly-selected patients from the Mayo Clinic registry. The 29-item survey questionnaire included items related to demographics, knowledge of digestive cancers, personal and family history of cancer, personal concern of cancer, colorectal cancer (CRC) screening behavior, interest in MUST, importance of test features in a cancer screening tool, and comparison of MUST with available CRC screening tests. All responses were summarized descriptively. χ2 and Rank Sum Test were used for categorical and continuous variables, respectively. RESULTS: Completed surveys were returned by 434 (29% aged 50-59, 37% 60-69, 34% 70-79, 52% women). Most participants (98%) responded they would use MUST. In order of importance, respondents rated multi-cancer detection, absence of bowel preparation, safety and noninvasiveness as most attractive characteristics. For CRC screening, MUST was preferred over colorectal-only stool-DNA testing (53%), occult blood testing (75%), colonoscopy (84%), sigmoidoscopy (91%), and barium enema (95%), P < 0.0001 for each. Among those not previously screened, most (96%) indicated they would use MUST if available. Respondents were confident in their ability to follow instructions to perform MUST (98%). Only 9% of respondents indicated that fear of finding cancer was a concern with MUST, and only 3% indicated unpleasantness of stool sampling as a potential barrier. CONCLUSION: Patients are receptive to the concept of MUST, preferred MUST over conventional CRC screening modalities and valued its potential feature of multi-cancer detection. PMID:24803808

  2. Performance of Emergency Department Screening Criteria for an Early ECG to Identify ST-Segment Elevation Myocardial Infarction.

    PubMed

    Yiadom, Maame Yaa A B; Baugh, Christopher W; McWade, Conor M; Liu, Xulei; Song, Kyoung Jun; Patterson, Brian W; Jenkins, Cathy A; Tanski, Mary; Mills, Angela M; Salazar, Gilberto; Wang, Thomas J; Dittus, Robert S; Liu, Dandan; Storrow, Alan B

    2017-02-23

    Timely diagnosis of ST-segment elevation myocardial infarction (STEMI) in the emergency department (ED) is made solely by ECG. Obtaining this test within 10 minutes of ED arrival is critical to achieving the best outcomes. We investigated variability in the timely identification of STEMI across institutions and whether performance variation was associated with the ED characteristics, the comprehensiveness of screening criteria, and the STEMI screening processes. We examined STEMI screening performance in 7 EDs, with the missed case rate (MCR) as our primary end point. The MCR is the proportion of primarily screened ED patients diagnosed with STEMI who did not receive an ECG within 15 minutes of ED arrival. STEMI was defined by hospital discharge diagnosis. Relationships between the MCR and ED characteristics, screening criteria, and STEMI screening processes were assessed, along with differences in door-to-ECG times for captured versus missed patients. The overall MCR for all 7 EDs was 12.8%. The lowest and highest MCRs were 3.4% and 32.6%, respectively. The mean difference in door-to-ECG times for captured and missed patients was 31 minutes, with a range of 14 to 80 minutes of additional myocardial ischemia time for missed cases. The prevalence of primarily screened ED STEMIs was 0.09%. EDs with the greatest informedness (sensitivity+specificity-1) demonstrated superior performance across all other screening measures. The 29.2% difference in MCRs between the highest and lowest performing EDs demonstrates room for improving timely STEMI identification among primarily screened ED patients. The MCR and informedness can be used to compare screening across EDs and to understand variable performance. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  3. Effect of Planned Follow-up on Married Women's Health Beliefs and Behaviors Concerning Breast and Cervical Cancer Screenings.

    PubMed

    Kolutek, Rahsan; Avci, Ilknur Aydin; Sevig, Umit

    2018-04-01

    The objective of this study was to identify the effect of planned follow-up visits on married women's health beliefs and behaviors concerning breast and cervical cancer screenings. The study was conducted using the single-group pre-test/post-test and quasi-experimental study designs. The sample of the study included 153 women. Data were collected using a Personal Information Form, the Health Belief Model (HBM) Scale for Breast Cancer Screening, the HBM Scale for Cervical Cancer Screening, and a Pap smear test. Data were collected using the aforementioned tools from September 2012 to March 2013. Four follow-up visits were conducted, nurses were educated, and telephone reminders were utilized. Friedman's test, McNemar's test, and descriptive statistics were used for data analyzing. The frequency of performing breast self-examination (BSE) at the last visit increased to 84.3 % compared to the pre-training. A statistically significant difference was observed between the pre- and post-training median values in four subscales except for the subscale of perceived seriousness of cervical cancer under "the Health Belief Model Scale for Cervical Cancer and the Pap Smear Test" (p < 0.001). The rate of performing BSE significantly increased after the training and follow-up visits. Also, the rate of having a Pap smear significantly increased after the follow-up visits.

  4. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. Results of a Targeted Screening Program for Congenital Cytomegalovirus Infection in Infants Who Fail Newborn Hearing Screening.

    PubMed

    Vancor, Emily; Shapiro, Eugene D; Loyal, Jaspreet

    2018-01-24

    Congenital cytomegalovirus (CMV) infection is a major cause of sensorineural hearing loss. By law, newborns in Connecticut who fail newborn hearing screening are tested for infection with CMV. This targeted screening is controversial, because most children with congenital CMV infection are asymptomatic, and CMV-related hearing loss can have a delayed onset. Our hospital uses a saliva polymerase chain reaction (PCR) assay (confirmed by a urine PCR assay) to detect CMV. Here, we report the results of the first year of our screening program. We reviewed the medical records of newborns in the Yale New Haven Health System who failed the newborn hearing screening test between January 1 and December 31, 2016. Of 10964 newborns, 171 failed newborn hearing screening, and 3 of these newborns had positive saliva CMV PCR test results. Of these 3 newborns, 2 had positive results on the confirmatory test (for 1 of them the confirmatory test was not performed until the infant was 10 weeks old), and 1 had a negative result on the confirmatory test. Three additional newborns with congenital CMV infection were tested because of clinical indications (1 for ventriculomegaly on prenatal ultrasound and 2 for CMV infection of the mother). Results of audiology follow-up were available for 149 (87.1%) of the 171 newborns who failed newborn hearing screening; 127 (85.2%) had normal results. Our targeted screening program for congenital CMV infection had a low yield. Consideration should be given to other strategies for identifying children at risk of hearing loss as a result of congenital CMV infection. © The Author(s) 2018. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Screening of cervical cancer in Catalonia 2006-2012.

    PubMed

    de Sanjosé, Silvia; Ibáñez, Raquel; Rodríguez-Salés, Vanesa; Peris, Mercè; Roura, Esther; Diaz, Mireia; Torné, Aureli; Costa, Dolors; Canet, Yolanda; Falguera, Gemma; Alejo, Maria; Espinàs, Josep Alfons; Bosch, F Xavier

    2015-01-01

    The early detection of intraepithelial lesions of the cervix, through the periodic examination of cervical cells, has been fundamental for the prevention of invasive cervical cancer and its related mortality. In this report, we summarise the cervical cancer screening activities carried out in Catalonia, Spain, within the National Health System during 2008-2011. The study population covers over two million women resident in the area. The evaluation includes 758,690 cervical cytologies performed on a total of 595,868 women. The three-year coverage of cervical cytology among women aged between 25 and 65 years was 40.8%. About 50% of first screened women with negative results had not returned to the second screening round. The introduction of high-risk human papillomavirus DNA (HPV) detection, as a primary screening cotest with cytology among women over age 40 with a poor screening history, significantly improved the detection of cervical intraepithelial neoplasia grade 2 or worse (CIN2+), being far superior to cytology alone. Cotesting did not improve the detection of CIN2+. The use of the HPV test for the triage of atypical squamous cell undetermined significance (ASC-US) improved the selection of women at high risk of CIN2+. Sampling (both cytology and HPV test) was largely performed by midwives (66.7%), followed by obstetricians (23.8%) and nurses (7%). Over half of the centres (54.8%) had full use of online medical records. During the study period, educational activities for professionals and for women were carried out periodically. The organisation of screening as a population activity in which women are actively called to the screening visit and the introduction of HPV testing as a primary screening tool are strongly recommended to ensure the maximum population impact in the reduction of the cervical cancer burden.

  7. Screening of cervical cancer in Catalonia 2006–2012

    PubMed Central

    de Sanjosé, Silvia; Ibáñez, Raquel; Rodríguez-Salés, Vanesa; Peris, Mercè; Roura, Esther; Diaz, Mireia; Torné, Aureli; Costa, Dolors; Canet, Yolanda; Falguera, Gemma; Alejo, Maria; Espinàs, Josep Alfons; Bosch, F. Xavier

    2015-01-01

    The early detection of intraepithelial lesions of the cervix, through the periodic examination of cervical cells, has been fundamental for the prevention of invasive cervical cancer and its related mortality. In this report, we summarise the cervical cancer screening activities carried out in Catalonia, Spain, within the National Health System during 2008–2011. The study population covers over two million women resident in the area. The evaluation includes 758,690 cervical cytologies performed on a total of 595,868 women. The three-year coverage of cervical cytology among women aged between 25 and 65 years was 40.8%. About 50% of first screened women with negative results had not returned to the second screening round. The introduction of high-risk human papillomavirus DNA (HPV) detection, as a primary screening cotest with cytology among women over age 40 with a poor screening history, significantly improved the detection of cervical intraepithelial neoplasia grade 2 or worse (CIN2+), being far superior to cytology alone. Cotesting did not improve the detection of CIN2+. The use of the HPV test for the triage of atypical squamous cell undetermined significance (ASC-US) improved the selection of women at high risk of CIN2+. Sampling (both cytology and HPV test) was largely performed by midwives (66.7%), followed by obstetricians (23.8%) and nurses (7%). Over half of the centres (54.8%) had full use of online medical records. During the study period, educational activities for professionals and for women were carried out periodically. The organisation of screening as a population activity in which women are actively called to the screening visit and the introduction of HPV testing as a primary screening tool are strongly recommended to ensure the maximum population impact in the reduction of the cervical cancer burden. PMID:25987901

  8. Introducing social cues in multimedia learning: The role of pedagogic agents' image and language in a scientific lesson

    NASA Astrophysics Data System (ADS)

    Moreno, Roxana Arleen

    The present dissertation tested the hypothesis that software pedagogical agents can promote constructivist learning in a discovery-based multimedia environment. In a preliminary study, students who received a computer-based lesson on environmental science performed better on subsequent tests of problem solving and motivation when they learned with the mediation of a fictional agent compared to when they learned the same material from text. In order to investigate further the basis for this personal agent effect, I varied whether the agent's words were presented as speech or on-screen text and whether or not the agent's image appeared on the screen. Both with a fictional agent (Experiment 1) and a video of a human face (Experiment 2), students performed better on tests of retention, problem-solving transfer, and program ratings when words were presented as speech rather than on-screen text (producing a modality effect) but visual presence of the agent did not affect test performance (producing no image effect). Next, I varied whether or not the agent's words were presented in conversational style (i.e., as dialogue) or formal style (i.e., as monologue) both using speech (Experiment 3) and on-screen text (Experiment 4). In both experiments, there was a dialogue effect in which conversational-style produced better retention and transfer performance. Students who learned with conversational-style text rated the program more favorably than those who learned with monologue-style text. The results support cognitive principles of multimedia learning which underlie the understanding of a computer lesson about a complex scientific system.

  9. Dementia Screening Accuracy is Robust to Premorbid IQ Variation: Evidence from the Addenbrooke's Cognitive Examination-III and the Test of Premorbid Function.

    PubMed

    Stott, Joshua; Scior, Katrina; Mandy, William; Charlesworth, Georgina

    2017-01-01

    Scores on cognitive screening tools for dementia are associated with premorbid IQ. It has been suggested that screening scores should be adjusted accordingly. However, no study has examined whether premorbid IQ variation affects screening accuracy. To investigate whether the screening accuracy of a widely used cognitive screening tool for dementia, the Addenbrooke's cognitive examination-III (ACE-III), is improved by adjusting for premorbid IQ. 171 UK based adults (96 memory service attendees diagnosed with dementia and 75 healthy volunteers over the age of 65 without subjective memory impairments) completed the ACE-III and the Test of Premorbid Function (TOPF). The difference in screening performance between the ACE-III alone and the ACE-III adjusted for TOPF was assessed against a reference standard; the presence or absence of a diagnosis of dementia (Alzheimer's disease, vascular dementia, or others). Logistic regression and receiver operating curve analyses indicated that the ACE-III has excellent screening accuracy (93% sensitivity, 94% specificity) in distinguishing those with and without a dementia diagnosis. Although ACE-III scores were associated with TOPF scores, TOPF scores may be affected by having dementia and screening accuracy was not improved by accounting for premorbid IQ, age, or years of education. ACE-III screening accuracy is high and screening performance is robust to variation in premorbid IQ, age, and years of education. Adjustment of ACE-III cut-offs for premorbid IQ is not recommended in clinical practice. The analytic strategy used here may be useful to assess the impact of premorbid IQ on other screening tools.

  10. Development and application of a general plasmid reference material for GMO screening.

    PubMed

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Biological variability of transferrin saturation and unsaturated iron binding capacity

    PubMed Central

    Adams, PC; Reboussin, DM; Press, RD; Barton, JC; Acton, RT; Moses, GC; Leiendecker-Foster, C; McLaren, GD; Dawkins, FW; Gordeuk, VR; Lovato, L; Eckfeldt, JH

    2007-01-01

    Background Transferrin saturation is widely considered the preferred screening test for hemochromatosis. Unsaturated iron binding capacity has similar performance at lower cost. However, the within-person biological variability of both these tests may limit their ability at commonly used cut points to detect HFE C282Y homozygous patients. Methods The Hemochromatosis and Iron Overload Screening (HEIRS) Study screened 101,168 primary care participants for iron overload using tansferrin saturation, unsaturated iron binding capacity, ferritin and HFE C282Y and H63D genotyping. Transferrin saturation and unsaturated iron binding capacity were performed at initial screening and again when selected participants and controls returned for a clinical examination several months later. A missed case was defined as a C282Y homozygote who had transferrin saturation below cut point (45 % women, 50 % men) or unsaturated iron binding capacity above cut point (150 μmol/L women, 125 μmol/L men) at either the initial screening or clinical examination, or both, regardless of serum ferritin. Results There were 209 C282Y previously undiagnosed homozygotes with transferrin saturation and unsaturated iron binding capacity testing done at initial screening and clinical examination. Sixty-eight C282Y homozygotes (33%) would have been missed at these transferrin saturation cut points (19 men, 49 women, median SF 170 μg/L, first and third quartiles 50 and 474 μg/L), and 58 homozygotes (28 %) would have been missed at the unsaturated iron binding capacity cut points (20 men, 38 women, median SF 168 μg/L, quartiles 38 and 454 μg/L). There was no advantage to using fasting samples. Conclusions The within-person biological variability of transferrin saturation and unsaturated iron binding capacity limit their usefulness as an initial screening test for expressing C282Y homozygotes. PMID:17976429

  12. Organised colorectal cancer screening in Lampang Province, Thailand: preliminary results from a pilot implementation programme

    PubMed Central

    Khuhaprema, Thiravud; Sangrajrang, Suleeporn; Lalitwongsa, Somkiat; Chokvanitphong, Vanida; Raunroadroong, Tawarat; Ratanachu-ek, Tawee; Muwonge, Richard; Lucas, Eric; Wild, Christopher; Sankaranarayanan, Rengaswamy

    2014-01-01

    Objective Colorectal cancer (CRC) is the third-most and fifth-most common cancer in men and women, in Thailand. The increasing CRC incidence and mortality can be reduced by screening and treating adenomas and early cancers. A pilot CRC screening programme using immunochemical faecal occult blood testing (iFOBT) and colonoscopy for test-positives were implemented through the routine Government Health Services in Lampang Province, to inform the acceptability, feasibility and scaling-up of screening in Thailand. This report describes the implementation, coverage and performance indicators of this project. Design A target population aged 50–65 years was informed about and invited face to face to undergo CRC screening by community health workers (HWs). The HWs provided faecal sample collection kits and participants brought their samples to one of the primary health units or community hospitals where nurses performed iFOBT. iFOBT-positive persons were referred for colonoscopy at the Lampang cancer hospital, and endoscopic polypectomy/biopsies were performed according to the colonoscopic findings. Those with confirmed CRC received appropriate treatment. Results Of the 127 301 target population, 62.9% were screened using iFOBT between April 2011 and November 2012. Participation was higher among women (67.8%) than men (57.8%) and lower in 50–54 year-old persons than in 60–65-year-olds. Of those screened, 873 (1.1%) were found positive; positivity was higher in men (1.2%) than in women (1.0%). To date 627 (72.0%) iFOBT-positive persons have had colonoscopy in which 3.7% had CRC and 30.6% had adenomas. Conclusions The successful implementation of the pilot CRC screening with satisfactory process measures indicate the feasibility of scaling-up organised CRC screening through existing health services in Thailand. PMID:24435889

  13. Impact of HPV testing, HPV vaccine development, and changing screening frequency on national Pap test volume: projections from the National Health Interview Survey (NHIS).

    PubMed

    Eltoum, Isam A; Roberson, Janie

    2007-02-25

    The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future. This, in turn, will decrease the demand for a traditionally trained cytotechnology workforce. (c) 2007 American Cancer Society.

  14. Prenatal screening for fetal aneuploidy in singleton pregnancies.

    PubMed

    Chitayat, David; Langlois, Sylvie; Douglas Wilson, R

    2011-07-01

    To develop a Canadian consensus document on maternal screening for fetal aneuploidy (e.g., Down syndrome and trisomy 18) in singleton pregnancies. Pregnancy screening for fetal aneuploidy started in the mid 1960s, using maternal age as the screening test. New developments in maternal serum and ultrasound screening have made it possible to offer all pregnant patients a non-invasive screening test to assess their risk of having a fetus with aneuploidy to determine whether invasive prenatal diagnostic testing is necessary. This document reviews the options available for non-invasive screening and makes recommendations for Canadian patients and health care workers. To offer non-invasive screening for fetal aneuploidy (trisomy 13, 18, 21) to all pregnant women. Invasive prenatal diagnosis would be offered to women who screen above a set risk cut-off level on non-invasive screening or to pregnant women whose personal, obstetrical, or family history places them at increased risk. Currently available non-invasive screening options include maternal age combined with one of the following: (1) first trimester screening (nuchal translucency, maternal age, and maternal serum biochemical markers), (2) second trimester serum screening (maternal age and maternal serum biochemical markers), or (3) 2-step integrated screening, which includes first and second trimester serum screening with or without nuchal translucency (integrated prenatal screen, serum integrated prenatal screening, contingent, and sequential). These options are reviewed, and recommendations are made. Studies published between 1982 and 2009 were retrieved through searches of PubMed or Medline and CINAHL and the Cochrane Library, using appropriate controlled vocabulary and key words (aneuploidy, Down syndrome, trisomy, prenatal screening, genetic health risk, genetic health surveillance, prenatal diagnosis). Results were restricted to systematic reviews, randomized controlled trials, and relevant observational studies. There were no language restrictions. Searches were updated on a regular basis and incorporated in the guideline to August 2010. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The previous Society of Obstetricians and Gynaecologists of Canada guidelines regarding prenatal screening were also reviewed in developing this clinical practice guideline. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care. This guideline is intended to reduce the number of prenatal invasive procedures done when maternal age is the only indication. This will have the benefit of reducing the numbers of normal pregnancies lost because of complications of invasive procedures. Any screening test has an inherent false-positive rate, which may result in undue anxiety. It is not possible at this time to undertake a detailed cost-benefit analysis of the implementation of this guideline, since this would require health surveillance and research and health resources not presently available; however, these factors need to be evaluated in a prospective approach by provincial and territorial initiatives. RECOMMENDATIONS 1. All pregnant women in Canada, regardless of age, should be offered, through an informed counselling process, the option of a prenatal screening test for the most common clinically significant fetal aneuploidies in addition to a second trimester ultrasound for dating, assessment of fetal anatomy, and detection of multiples. (I-A) 2. Counselling must be non-directive and must respect a woman's right to accept or decline any or all of the testing or options offered at any point in the process. (III-A) 3. Maternal age alone is a poor minimum standard for prenatal screening for aneuploidy, and it should not be used a basis for recommending invasive testing when non-invasive prenatal screening for aneuploidy is available. (II-2A) 4. Invasive prenatal diagnosis for cytogenetic analysis should not be performed without multiple marker screening results except for women who are at increased risk of fetal aneuploidy (a) because of ultrasound findings, (b) because the pregnancy was conceived by in vitro fertilization with intracytoplasmic sperm injection, or (c) because the woman or her partner has a history of a previous child or fetus with a chromosomal abnormality or is a carrier of a chromosome rearrangement that increases the risk of having a fetus with a chromosomal abnormality. (II-2E) 5. At minimum, any prenatal screen offered to Canadian women who present for care in the first trimester should have a detection rate of 75% with no more than a 3% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 6. The minimum standard for women presenting in the second trimester should be a screen that has a detection rate of 75% with no more than a 5% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 7. First trimester nuchal translucency should be interpreted for risk assessment only when measured by sonographers or sonologists trained and accredited for this service and when there is ongoing quality assurance (II-2A), and it should not be offered as a screen without biochemical markers in singleton pregnancies. (I-E) 8. Evaluation of the fetal nasal bone in the first trimester should not be incorporated as a screen unless it is performed by sonographers or sonologists trained and accredited for this service and there is ongoing quality assurance. (II-2E) 9. For women who undertake first trimester screening, second trimester serum alpha fetoprotein screening and/or ultrasound examination is recommended to screen for open neural tube defects. (II-1A) 10. Timely referral and access is critical for women and should be facilitated to ensure women are able to undergo the type of screening test they have chosen as first trimester screening. The first steps of integrated screening (with or without nuchal translucency), contingent, or sequential screening are performed in an early and relatively narrow time window. (II-1A) 11. Ultrasound dating should be performed if menstrual or conception dating is unreliable. For any abnormal serum screen calculated on the basis of menstrual dating, an ultrasound should be done to confirm gestational age. (II-1A) 12. The presence or absence of soft markers or anomalies in the 18- to 20-week ultrasound can be used to modify the a priori risk of aneuploidy established by age or prior screening. (II-2B) 13. Information such as gestational dating, maternal weight, ethnicity, insulin-dependent diabetes mellitus, and use of assisted reproduction technologies should be provided to the laboratory to improve accuracy of testing. (II-2A) 14. Health care providers should be aware of the screening modalities available in their province or territory. (III-B) 15. A reliable system needs to be in place ensuring timely reporting of results. (III-C) 16. Screening programs should be implemented with resources that support audited screening and diagnostic laboratory services, ultrasound, genetic counselling services, patient and health care provider education, and high quality diagnostic testing, as well as resources for administration, annual clinical audit, and data management. In addition, there must be the flexibility and funding to adjust the program to new technology and protocols. (II-3B).

  15. Virtual daily living test to screen for mild cognitive impairment using kinematic movement analysis

    PubMed Central

    Seo, Kyoungwon; Kim, Jae-kwan; Oh, Dong Hoon

    2017-01-01

    Questionnaires or computer-based tests for assessing activities of daily living are well-known approaches to screen for mild cognitive impairment (MCI). However, questionnaires are subjective and computerized tests only collect simple performance data with conventional input devices such as a mouse and keyboard. This study explored the validity and discriminative power of a virtual daily living test as a new diagnostic approach to assess MCI. Twenty-two healthy controls and 20 patients with MCI were recruited. The virtual daily living test presents two complex daily living tasks in an immersive virtual reality environment. The tasks were conducted based on subject body movements and detailed behavioral data (i.e., kinematic measures) were collected. Performance in both the proposed virtual daily living test and conventional neuropsychological tests for patients with MCI was compared to healthy controls. Kinematic measures considered in this study, such as body movement trajectory, time to completion, and speed, classified patients with MCI from healthy controls, F(8, 33) = 5.648, p < 0.001, η2 = 0.578. When both hand and head speed were employed in conjunction with the immediate free-recall test, a conventional neuropsychological test, the discrimination power for screening MCI was significantly improved to 90% sensitivity and 95.5% specificity (cf. the immediate free-recall test alone has 80% sensitivity and 77.3% specificity). Inclusion of the kinematic measures in screening for MCI significantly improved the classification of patients with MCI compared to the healthy control group, Wilks’ Lambda = 0.451, p < 0.001. PMID:28738088

  16. [Uniform analyzes of drugs in urine needed for rule of law].

    PubMed

    Hansson, Therese; Helander, Anders; Beck, Olof; Elmgren, Anders; Kugelberg, Fredrik; Kronstrand, Robert

    2015-09-22

    Drugs of abuse testing is used in various areas of society for detection and follow-up of drug use. In routine laboratory drug testing, immunoassays are employed for initial screening of specimens to indicate the presence of drugs. To confirm a positive screening test, a secondary analysis by mass spectrometry is performed. The "cut-off" is the pre-defined concentration threshold of a drug or drug metabolite above which the sample is considered positive. A reading below this level implies a negative test result. Swedish drug testing laboratories currently employ varying cut-offs to distinguish between a positive and a negative test result. Because a positive drug test may have serious legal consequences to the individual, it is of importance that testing is performed and judged equally, regardless of where it is performed. A national harmonization of cut-offs is therefore warranted. Based on data from four major Swedish drug testing laboratories, and considering the recommendations in international guidelines, a proposal for national harmonization of urine cut-offs for the most common set of drugs of abuse is presented.

  17. Does Assessing Eye Alignment along with Refractive Error or Visual Acuity Increase Sensitivity for Detection of Strabismus in Preschool Vision Screening?

    PubMed Central

    2007-01-01

    Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881

  18. New technologies in cervical cancer precursor detection.

    PubMed

    Soler, M E; Blumenthal, P D

    2000-09-01

    The current literature reflects three routes toward improving cervical cancer screening. The first is to improve the test qualities of cytology-based screening. The use of liquid-based cytology and computerized analysis of Papanicolaou tests are examples of attempts at this approach. Secondly, through various combinations of parallel or sequential tests, either the sensitivity or the specificity of a given test could be improved depending on the tests chosen and the order in which they were performed (eg, Papanicolaou test followed by human papillomavirus [HPV] or vice versa). Several excellent studies have been published this year on the use of HPV DNA testing as a primary screening modality and as an adjunct to the triage of mildly abnormal cytologic findings. The recent literature also reflects increasing interest in visual inspection of the cervix and self-collected samples for HPV testing as an equally effective and viable alternative to cytology in low-resource settings. A third possibility is to make use of advances in digital and spectroscopic techniques. In these cost-conscious times, a significant number of articles address the cost-effectiveness of these technologies and the real value of cervical cancer screening. This article reviews the current literature concerning both the advent of new cervical cancer screening technologies and the rediscovery of old ones.

  19. Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peascoe, RA

    2001-09-25

    Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less

  20. [Significance of Septin9 gene methylation detection of plasma circulation DNA in colorectal cancer screening].

    PubMed

    Kang, Qian; Jin, Peng; Yang, Lang; Wang, Xin; An, Hejuan; Liu, Lili; Li, Na; Sheng, Jianqiu

    2014-12-30

    To explore the role of detecting the methylation status of gene Septin9 (SEPT9) in plasma for colorectal cancer screening in Chinese population. Patients were collected from Beijing Military General Hospital since September 2013 to February 2014. The performance of SEPT9 assay was validated in a single-blind study of 80 cases with colonoscopy and pathologically verified colorectal cancer and 52 normal controls. The detection of Septin9 gene methylation in peripheral blood was performed by fluorescence quantitative polymerase chain reaction (PCR). And immunoassay fecal occult blood test was conducted to compare the superiority of methylated Septin9 for screening colorectal cancer. The Septin9 assay successfully identified 75.0% (95%CI:64.7%-83.6%) of cancers at a specificity of 98.1% (95%CI:90.9%-99.9%). And it was superior to fecal occult blood screening for colorectal cancer (sensitivity 79.5% vs 53.8%, P < 0.05). Determination of SEPT9 methylation status is an innovative non-invasive plasma screening test for colorectal cancer.

  1. Cost-effectiveness of computed tomography colonography in colorectal cancer screening: a systematic review.

    PubMed

    Hanly, Paul; Skally, Mairead; Fenlon, Helen; Sharp, Linda

    2012-10-01

    The European Code Against Cancer recommends individuals aged ≥ 50 should participate in colorectal cancer screening. CT-colonography (CTC) is one of several screening tests available. We systematically reviewed evidence on, and identified key factors influencing, cost-effectiveness of CTC screening. PubMed, Medline, and the Cochrane library were searched for cost-effectiveness or cost-utility analyses of CTC-based screening, published in English, January 1999 to July 2010. Data was abstracted on setting, model type and horizon, screening scenario(s), comparator(s), participants, uptake, CTC performance and cost, effectiveness, ICERs, and whether extra-colonic findings and medical complications were considered. Sixteen studies were identified from the United States (n = 11), Canada (n = 2), and France, Italy, and the United Kingdom (1 each). Markov state-transition (n = 14) or microsimulation (n = 2) models were used. Eleven considered direct medical costs only; five included indirect costs. Fourteen compared CTC with no screening; fourteen compared CTC with colonoscopy-based screening; fewer compared CTC with sigmoidoscopy (8) or fecal tests (4). Outcomes assessed were life-years gained/saved (13), QALYs (2), or both (1). Three considered extra-colonic findings; seven considered complications. CTC appeared cost-effective versus no screening and, in general, flexible sigmoidoscopy and fecal occult blood testing. Results were mixed comparing CTC to colonoscopy. Parameters most influencing cost-effectiveness included: CTC costs, screening uptake, threshold for polyp referral, and extra-colonic findings. Evidence on cost-effectiveness of CTC screening is heterogeneous, due largely to between-study differences in comparators and parameter values. Future studies should: compare CTC with currently favored tests, especially fecal immunochemical tests; consider extra-colonic findings; and conduct comprehensive sensitivity analyses.

  2. Integrating Routine HIV Screening in the New York City Community Health Center Collaborative.

    PubMed

    Rodriguez, Vanessa; Lester, Deborah; Connelly-Flores, Alison; Barsanti, Franco A; Hernandez, Paloma

    2016-01-01

    One in seven of the 1.1 million people living in the United States infected with HIV are not aware of their HIV status. At the same time, many clinical settings have not adopted routine HIV screening, which promotes linkage to specialist medical care. We sought to improve HIV screening in a large community health center network by using a data-driven, collaborative learning approach and system-wide modifications, where counselor-based HIV screening and testing were replaced by health-care providers and medical assistants. Urban Health Plan, Inc., a network of federally qualified health centers in the boroughs of the Bronx and Queens in New York City, provided HIV screening training for its health-care providers. In January 2011, it modified its electronic medical record system to incorporate HIV test offering. This study compared the 2010 baseline year with the three-year implementation follow-up period (January 2011 through December 2013) to determine the number of eligible individuals for HIV testing, HIV tests offered and performed, HIV-positive individuals, and HIV cases linked to specialty care. A total of 26,853 individuals at baseline and 100,369 individuals in the implementation period were eligible for HIV testing. HIV testing was performed on 2,079 (8%) of 26,853 eligible individuals in 2010 and 49,646 (50%) of 100,369 eligible individuals from 2011 through 2013. HIV-positive status was determined in 19 (0.9%) of 2,079 tested individuals in 2010 and 166 (0.3%) of 49,646 tested individuals from 2011 through 2013. Linkage to care was observed in all 19 eligible individuals and 127 (77%) of 166 eligible individuals who tested HIV positive in 2010 and 2011-2013, respectively. This study enabled routine HIV implementation testing at a community health center network, which resulted in enhanced HIV testing, an increased number of HIV-positive cases identified, and a rise in the number of patients linked to HIV specialist care.

  3. Improved 5-year survival of patients with immunochemical faecal blood test-screen-detected colorectal cancer versus non-screening cancers in northern Italy.

    PubMed

    Parente, Fabrizio; Vailati, Cristian; Boemo, Cinzia; Bonoldi, Emanuela; Ardizzoia, Antonio; Ilardo, Antonina; Tortorella, Franco; Cereda, Danilo; Cremaschini, Marco; Moretti, Roberto

    2015-01-01

    Colorectal cancer screening may reduce disease-related mortality by early-stage detection of cancers. To study the effect of a single immunochemical faecal occult blood test (i-FOBt) screening round on reduction in colorectal cancer-related-mortality among average risk subjects. Comparison of 5-year mortality rates in 3 cohorts from a Northern Italian province: (1) colorectal cancers detected at the 1st biennial round of a mass-screening programme targeting 50-69 years old subjects, (2) non-screening cancers symptomatically diagnosed during the same time period, and (3) cancers detected in the pre-screening biennium. Multivariate analyses were performed with the Cox regression model including tumour node metastasis (TNM) stage at diagnosis, anatomical distribution of cancers, age at diagnosis, gender and patient group. Kaplan-Meyer survival estimates and log-rank test for equality of survivor functions were calculated. Stage distribution significantly differed between screening and non-screening colorectal cancers: 73% of screen-detected colorectal cancers were stages I and II versus 43% and 40% of non-screening and pre-screening colorectal cancers. Cumulative 5-year mortality rate was significantly lower in screening compared to non-screening or pre-screening colorectal cancers patients (19% versus 37% and 41%, p < 0.001). Colorectal cancers were detected at earlier stages in i-FOBT-positive subjects in comparison with non-screening patients; colorectal cancers found at screening had a significantly improved 5-year survival. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Development of a computer-based automated pure tone hearing screening device: a preliminary clinical trial.

    PubMed

    Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah

    2012-10-01

    Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.

  5. The Clinical and Economic Benefits of Co-Testing Versus Primary HPV Testing for Cervical Cancer Screening: A Modeling Analysis.

    PubMed

    Felix, Juan C; Lacey, Michael J; Miller, Jeffrey D; Lenhart, Gregory M; Spitzer, Mark; Kulkarni, Rucha

    2016-06-01

    Consensus United States cervical cancer screening guidelines recommend use of combination Pap plus human papillomavirus (HPV) testing for women aged 30 to 65 years. An HPV test was approved by the Food and Drug Administration in 2014 for primary cervical cancer screening in women age 25 years and older. Here, we present the results of clinical-economic comparisons of Pap plus HPV mRNA testing including genotyping for HPV 16/18 (co-testing) versus DNA-based primary HPV testing with HPV 16/18 genotyping and reflex cytology (HPV primary) for cervical cancer screening. A health state transition (Markov) model with 1-year cycling was developed using epidemiologic, clinical, and economic data from healthcare databases and published literature. A hypothetical cohort of one million women receiving triennial cervical cancer screening was simulated from ages 30 to 70 years. Screening strategies compared HPV primary to co-testing. Outcomes included total and incremental differences in costs, invasive cervical cancer (ICC) cases, ICC deaths, number of colposcopies, and quality-adjusted life years for cost-effectiveness calculations. Comprehensive sensitivity analyses were performed. In a simulation cohort of one million 30-year-old women modeled up to age 70 years, the model predicted that screening with HPV primary testing instead of co-testing could lead to as many as 2,141 more ICC cases and 2,041 more ICC deaths. In the simulation, co-testing demonstrated a greater number of lifetime quality-adjusted life years (22,334) and yielded $39.0 million in savings compared with HPV primary, thereby conferring greater effectiveness at lower cost. Model results demonstrate that co-testing has the potential to provide improved clinical and economic outcomes when compared with HPV primary. While actual cost and outcome data are evaluated, these findings are relevant to U.S. healthcare payers and women's health policy advocates seeking cost-effective cervical cancer screening technologies.

  6. Test-retest reliability of jump execution variables using mechanography: A comparison of jump protocols

    USDA-ARS?s Scientific Manuscript database

    Mechanography during the vertical jump test allows for evaluation of force-time variables reflecting jump execution, which may enhance screening for functional deficits that reduce physical performance and determining mechanistic causes underlying performance changes. However, utility of jump mechan...

  7. Screening methods for assessment of biodegradability of chemicals in seawater--results from a ring test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyholm, N.; Kristensen, P.

    1992-04-01

    An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottlemore » test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.« less

  8. Cervical Cancer Screening Among Adult Women in China, 2010

    PubMed Central

    Wang, Baohua; He, Minfu; Chao, Ann; Engelgau, Michael M.; Saraiya, Mona; Wang, Limin

    2015-01-01

    Introduction. Cervical cancer is one of the most commonly diagnosed cancers among women in China. The World Health Organization (WHO) recommends routine screening for cervical cancer, and the WHO Global Monitoring Framework suggests that every nation monitors cervical cancer screening. However, little information is available on cervical cancer screening behavior among women in China. Methods. We used data from the 2010 China Chronic Disease and Risk Factor Surveillance System that included 51,989 women aged 18 years and older. We report the proportion of women who reported ever having had a Papanicolaou (Pap) test, stratified by sociodemographic characteristics and geographic region. Multivariable logistic regression modeling was performed to adjust for potential confounders. Results. Overall, 21% of 51,989 women reported having ever had a Pap test. The highest proportion was reported among women aged 30–39 years (30.1%, 95% confidence interval, 26.8%–33.4%). In all geographic regions, women in rural areas were consistently less likely than women in urban areas to report having had a Pap test. Among women who reported ever having a Pap test, 82% reported having the most recent test in the past 3 years. Factors associated with reporting ever having a test were being aged 30–49 years, higher education, being married, and having urban health insurance. Conclusion. Our results indicate that screening programs need to be strengthened along with a more intense focus on specific demographic groups. National cervical cancer screening guidelines and comprehensive implementation strategies are needed to make screening services available and accessible to all women. Implications for Practice: This study is the largest nationwide and population-based assessment of self-reported history of Pap test for cervical cancer screening in China. This article describes cervical cancer screening behavior among women and examines key demographic and geographic factors. Only one fifth of Chinese women reported having ever had a Pap test for cervical cancer screening. The results highlight the urgent need to develop national cervical cancer screening guidelines and strategies that make screening services widely available, accessible, and acceptable to all women, especially to those who reside in rural areas and those with no health insurance. PMID:25956407

  9. Colorectal Cancer Screening: Recommendations for Physicians and Patients From the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years. Copyright © 2017 AGA Institute, American College of Gastroenterology, and the American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  10. Secondary Waste Form Screening Test Results—Cast Stone and Alkali Alumino-Silicate Geopolymer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, Eric M.; Cantrell, Kirk J.; Westsik, Joseph H.

    2010-06-28

    PNNL is conducting screening tests on the candidate waste forms to provide a basis for comparison and to resolve the formulation and data needs identified in the literature review. This report documents the screening test results on the Cast Stone cementitious waste form and the Geopolymer waste form. Test results suggest that both the Cast Stone and Geopolymer appear to be viable waste forms for the solidification of the secondary liquid wastes to be treated in the ETF. The diffusivity for technetium from the Cast Stone monoliths was in the range of 1.2 × 10-11 to 2.3 × 10-13 cm2/smore » during the 63 days of testing. The diffusivity for technetium from the Geopolymer was in the range of 1.7 × 10-10 to 3.8 × 10-12 cm2/s through the 63 days of the test. These values compare with a target of 1 × 10-9 cm2/s or less. The Geopolymer continues to show some fabrication issues with the diffusivities ranging from 1.7 × 10-10 to 3.8 × 10-12 cm2/s for the better-performing batch to from 1.2 × 10-9 to 1.8 × 10-11 cm2/s for the poorer-performing batch. In the future more comprehensive and longer term performance testing will be conducted, to further evaluate whether or not these waste forms will meet the regulation and performance criteria needed to cost-effectively dispose of secondary wastes.« less

  11. Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.

    PubMed

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.

  12. Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients

    PubMed Central

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310

  13. Introducing routine HIV screening for patients on an internal medicine residency inpatient service: a quality improvement project.

    PubMed

    Padrnos, Leslie J; Barr, Patrick J; Klassen, Christine L; Fields, Heather E; Azadeh, Natalya; Mendoza, Neil; Saadiq, Rayya A; Pauwels, Emanuel M; King, Christopher S; Chung, Andrew A; Sakata, Kenneth K; Blair, Janis E

    2016-01-01

    The US Centers for Disease Control and Prevention (CDC) recommend human immunodeficiency virus (HIV) screening for all persons aged 13 to 64 years who present to a health care provider. We sought to improve adherence to the CDC guidelines on the Internal Medicine Resident Hospital Service. We surveyed residents about the CDC guidelines, sent email reminders, provided education, and engaged them in friendly competition. Credit for guideline adherence was awarded if an offer of HIV screening was documented at admission, if a screening test was performed, or if a notation in the resident sign out sheet indicated why screening was not performed. We examined HIV screening of a postintervention group of patients admitted between August 8, 2012, and June 30, 2013, and compared them to a preintervention group admitted between August 1, 2011, and June 30, 2012. Postintervention offers of HIV screening increased significantly (7.9% [44/559] vs 55.5% [300/541]; P<.001), as did documentation of residents' contemplation of screening (8.9% [50/559] vs 67.5% [365/541]; P<.001). A significantly higher proportion of HIV screening tests was ordered postintervention (7.7% [43/559] vs 44.4% [240/541]; P<.001). Monthly HIV screening documentation ranged from 0% (0/53) to 17% (9/53) preintervention, whereas it ranged from 30.6% (11/36) to 100% (62/62) postintervention. HIV screening adherence can be improved through resident education, friendly competition, and system reminders. Barriers to achieving sustained adherence to the CDC guidelines include a heterogeneous patient population and provider discomfort with the subject.

  14. Evaluation of the King-Devick test as a concussion screening tool in high school football players.

    PubMed

    Seidman, Daniel H; Burlingame, Jennifer; Yousif, Lina R; Donahue, Xinh P; Krier, Joshua; Rayes, Lydia J; Young, Rachel; Lilla, Muareen; Mazurek, Rochelle; Hittle, Kristie; McCloskey, Charles; Misra, Saroj; Shaw, Michael K

    2015-09-15

    Concussion is the most common type of traumatic brain injury, and results from impact or impulsive forces to the head, neck or face. Due to the variability and subtlety of symptoms, concussions may go unrecognized or be ignored, especially with the pressure placed on athletes to return to competition. The King-Devick (KD) test, an oculomotor test originally designed for reading evaluation, was recently validated as a concussion screening tool in collegiate athletes. A prospective study was performed using high school football players in an attempt to study the KD as a concussion screening tool in this younger population. 343 athletes from four local high school football teams were recruited to participate. These athletes were given baseline KD tests prior to competition. Individual demographic information was collected on the subjects. Standard team protocol was employed to determine if a concussion had occurred during competition. Immediately after diagnosis, the KD test was re-administered to the concussed athlete for comparison to baseline. Post-season testing was also performed in non-concussed individuals. Of the 343 athletes, nine were diagnosed with concussions. In all concussed players, cumulative read times for the KD test were significantly increased (p<0.001). Post-season testing of non-concussed athletes revealed minimal change in read times relative to baseline. Univariate analysis revealed that history of concussion was the only demographic factor predictive of concussion in this cohort. The KD test is an accurate and easily administered sideline screening tool for concussion in adolescent football players. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Sensitivity of fetal RHD screening for safe guidance of targeted anti-D immunoglobulin prophylaxis: prospective cohort study of a nationwide programme in the Netherlands.

    PubMed

    de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C

    2016-11-07

     To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN:  Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined.  Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting.  25 789 RhD negative pregnant women.  Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme.  A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme.  Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. A pilot investigation on impact of participation in a long-term follow-up clinic (LTFU) on breast cancer and cardiovascular screening among women who received chest radiation for Hodgkin lymphoma.

    PubMed

    Baxstrom, K; Peterson, B A; Lee, C; Vogel, R I; Blaes, A H

    2018-02-07

    Women treated with chest radiation for Hodgkin lymphoma (HL) are at significantly increased risk of breast cancer and cardiovascular disease. HL survivors are recommended to have annual dual screening with mammogram (MMG) and breast magnetic resonance imaging (MRI). They are also recommended to undergo echocardiogram (echo) 5 years after completion of radiation. We performed a pilot study to characterize the women who are and are not receiving proper dual screening for breast cancer and baseline echo, and to examine the impact of a LTFU clinic consultation on screening. A retrospective chart review of 114 women treated for HL at University of Minnesota (UMN) between 1993 and 2009 was performed. Demographics, disease and treatment history (age at diagnosis, stage, radiation dose and field, chemotherapy, recurrence) were assessed, as well as screening practices (MMG, MRI, both and echo), participation in LTFU clinic, and recommendations from providers. Data was summated in yes/no (y/n) format; statistical analysis was performed using chi-squared and Fisher's exact tests. Breast cancer and cardiovascular screening outcomes were compared by participation in the LTFU clinic (y/n) using Fisher's exact tests. P values < 0.05 were considered statistically significant. Forty-one of 114 women met inclusion criteria and had follow-up data for analysis. Median age at diagnosis was 29 years; 67.6% were diagnosed at stage IIa. Median dose of radiation was 3570 cGy. 56.1% participated in the LTFU clinic at the UMN. 36.6% had dual screening with both MMG and MRI, 41.5% had screening with only MMG, and 19.5% had no screening performed. Women were more likely to have dual screening if they were seen in LTFU clinic vs not seen in LTFU clinic (52.2 vs 16.7%, p = 0.02). 67.5% of women were screened with echo; women were also more likely to have screening with echo if seen in LTFU clinic vs not seen (86.4 vs 44.4%, p = 0.007). Many women are not getting the proper dual screening for breast cancer despite their increased risk, with only 36.6% of our study sample getting dual screening. Having a consultation in a LTFU clinic increases dual screening for breast cancer and echo screening for cardiovascular disease. Proper screening allows for detection of secondary breast cancer at earlier stages where treatment can be local therapy. Diagnosing CV disease early could allow for proper preventative treatment or intervention.

  17. ScreenMasker: An Open-source Gaze-contingent Screen Masking Environment.

    PubMed

    Orlov, Pavel A; Bednarik, Roman

    2016-09-01

    The moving-window paradigm, based on gazecontingent technic, traditionally used in a studies of the visual perceptual span. There is a strong demand for new environments that could be employed by non-technical researchers. We have developed an easy-to-use tool with a graphical user interface (GUI) allowing both execution and control of visual gaze-contingency studies. This work describes ScreenMasker, an environment that allows create gaze-contingent textured displays used together with stimuli presentation software. ScreenMasker has an architecture that meets the requirements of low-latency real-time eye-movement experiments. It also provides a variety of settings and functions. Effective rendering times and performance are ensured by means of GPU processing under CUDA technology. Performance tests show ScreenMasker's latency to be 67-74 ms on a typical office computer, and high-end 144-Hz screen latencies of about 25-28 ms. ScreenMasker is an open-source system distributed under the GNU Lesser General Public License and is available at https://github.com/PaulOrlov/ScreenMasker .

  18. Screening for gonorrhoea using samples collected through the English national chlamydia screening programme and risk of false positives: a national survey of local authorities.

    PubMed

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-10-16

    To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. During May-July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15-24 years. (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450-4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17-67%. Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Bias-corrected diagnostic performance of the naked-eye single-tube red-cell osmotic fragility test (NESTROFT): an effective screening tool for beta-thalassemia.

    PubMed

    Mamtani, Manju; Jawahirani, Anil; Das, Kishor; Rughwani, Vinky; Kulkarni, Hemant

    2006-08-01

    It is being increasingly recognized that a majority of the countries in the thalassemia-belt need a cost-effective screening program as the first step towards control of thalassemia. Although the naked eye single tube red cell osmotic fragility test (NESTROFT) has been considered to be a very effective screening tool for beta-thalassemia trait, assessment of its diagnostic performance has been affected with the reference test- and verification-bias. Here, we set out to provide estimates of sensitivity and specificity of NESTROFT corrected for these potential biases. We conducted a cross-sectional diagnostic test evaluation study using data from 1563 subjects from Central India with a high prevalence of beta-thalassemia. We used latent class modelling after ensuring its validity to account for the reference test bias and global sensitivity analysis to control the verification bias. We also compared the results of latent class modelling with those of five discriminant indexes. We observed that across a range of cut-offs for the mean corpuscular volume (MCV) and the hemoglobin A2 (HbA2) concentration the average sensitivity and specificity of NESTROFT obtained from latent class modelling was 99.8 and 83.7%, respectively. These estimates were comparable to those characterizing the diagnostic performance of HbA2, which is considered by many as the reference test to detect beta-thalassemia. After correction for the verification bias these estimates were 93.4 and 97.2%, respectively. Combined with the inexpensive and quick disposition of NESTROFT, these results strongly support its candidature as a screening tool-especially in the resource-poor and high-prevalence settings.

  20. Milestone 4: Test plan for Reusable Hydrogen Composite Tank System (RHCTS). Task 3: Composite tank materials

    NASA Technical Reports Server (NTRS)

    Greenberg, H. S.

    1994-01-01

    This document is the detailed test plan for the series of tests enumerated in the preceding section. The purpose of this plan is to present the test objectives, test parameters and procedures, expected performance and data analysis plans, criteria for success, test schedules, and related safety provisions and to describe the test articles, test instrumentation, and test facility requirements. Initial testing will be performed to screen four composite materials for suitability for SSTO LH2 tank loads and environmental conditions. The laminates for this testing will be fabricated by fiber placement, which is the manufacturing approach identified as baseline for the tank wall. Even though hand layup will be involved in fabricating many of the internal structural members of the tank, no hand-layup laminates will be evaluated in the screening or subsequent characterization testing. This decision is based on the understanding that mechanical properties measured for hand-layup material should be at least equivalent to properties measured for fiber-placed material, so that the latter should provide no less than a conservative approximation of the former. A single material will be downselected from these screening tests. This material will be subsequently characterized for impact-damage tolerance and durability under conditions of mechanical and thermal cycling, and to establish a preliminary design database to support ongoing analysis. Next, testing will be performed on critical structural elements fabricated from the selected material. Finally, the 8-foot diameter tank article, containing the critical structural features of the full-scale tank, will be fabricated by fiber placement and tested to verify its structural integrity and LH2 containment.

  1. Plasma Septin9 versus Fecal Immunochemical Testing for Colorectal Cancer Screening: A Prospective Multicenter Study

    PubMed Central

    Johnson, David A.; Barclay, Robert L.; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T.

    2014-01-01

    Background Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. Objective To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. Design: In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Measurements Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. Results For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9–80.9%) and 68.0% (95% CI 58.2–76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5–86.3%) compared with 97.4% (95% CI 94.1–98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% –95% CI 62.5–80.1%) was shown to be statistically non-inferior to FIT (68.0%–95% CI 58.2–76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. Conclusions At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. Trial Registration ClinicalTrials.gov NCT01580540 PMID:24901436

  2. Harms of cervical cancer screening in the United States and the Netherlands.

    PubMed

    Habbema, Dik; Weinmann, Sheila; Arbyn, Marc; Kamineni, Aruna; Williams, Andrew E; M C M de Kok, Inge; van Kemenade, Folkert; Field, Terry S; van Rosmalen, Joost; Brown, Martin L

    2017-03-01

    We studied harms related to cervical cancer screening and management of screen-positive women in the United States (US) and the Netherlands. We utilized data from four US integrated health care systems (SEARCH), the US National Health Interview Survey, New Mexico state, the Netherlands national histopathology registry, and included studies on adverse health effects of cervical screening. We compared the number of Papanicolaou (Pap) smear tests, abnormal test results, punch biopsies, treatments, health problems (anxiety, pain, bleeding and discharge) and preterm births associated with excisional treatments. Results were age-standardized to the 2007 US population. Based on SEARCH, an estimated 36 million Pap tests were performed in 2007 for 91 million US women aged 21-65 years, leading to 2.3 million abnormal Pap tests, 1.5 million punch biopsies, 0.3 million treatments for precancerous lesions, 5 thousand preterm births and over 8 million health problems. Under the Netherlands screening practice, fewer Pap tests (58%), abnormal test results (64%), punch biopsies (75%), treatment procedures (40%), preterm births (60%) and health problems (63%) would have occurred. The SEARCH data did not differ much from other US data for 2007 or from more recent data up to 2013. Thus compared to the less intensive screening practice in the Netherlands, US practice of cervical cancer screening may have resulted in two- to threefold higher harms, while the effects on cervical cancer incidence and mortality are similar. The results are also of high relevance in making recommendations for HPV screening. Systematic collection of harms data is needed for monitoring and for better incorporation of harms in making screening recommendations. © 2016 UICC.

  3. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    PubMed

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  4. Experience of Routine Live-birth Screening for Galactosaemia in a British Hospital, with Emphasis on Heterozygote Detection

    PubMed Central

    Ellis, Graham; Wilcock, A. Ross; Goldberg, David M.

    1972-01-01

    Results are reported of a screening programme for galactosaemia covering a period of 2½ years and 6415 births. The gene frequency for galactosaemia estimated from the data of the screening programme was 0·002. This conflicted with the known live-birth incidence of at least 1: 50,000 during this same period. 2 of the 4 galactosaemic infants concerned died under circumstances that were preventable had they been screened at birth. The need to screen all sick infants for galactosaemia is emphasized, as is the requirement for reliable information on its incidence in Great Britain. The screening test employed (Beutler and Baluda, 1966a) seemed appropriate for this purpose. It was simple to perform and apparently accurate in galactosaemic infants. Its accuracy in detecting heterozygotes is uncertain. This test should be available in all hospitals receiving sick neonates. PMID:4401641

  5. Tier One Performance Screen Initial Operational Test and Evaluation: Early Results

    DTIC Science & Technology

    2011-04-01

    Requirement: In addition to educational, physical , and moral screens, the U.S. Army relies on a composite score from the Armed Services Vocational Aptitude...analyses suggest that the individual TAPAS scales significantly predict a number of criteria of interest. Most notably, the Physical Conditioning scale...predicted Soldiers’ self-reported Army Physical Fitness Test (APFT) scores, number of restarts in training, adjustment to Army life, and 3-month

  6. Economic evaluation of prostate cancer screening test as a national cancer screening program in South Korea.

    PubMed

    Shin, Sangjin; Kim, Youn Hee; Hwang, Jin Sub; Lee, Yoon Jae; Lee, Sang Moo; Ahn, Jeonghoon

    2014-01-01

    Prostate cancer is rapidly increasing in Korea and professional societies have requested adding prostate specific antigen (PSA) testing to the National Cancer Screening Program (NCSP), but this started a controversy in Korea and neutral evidence on this issue is required more than ever. The purpose of this study was to provide economic evidence to the decision makers of the NCSP. A cost-utility analysis was performed on the adoption of PSA screening program among men aged 50-74-years in Korea from the healthcare system perspective. Several data sources were used for the cost-utility analysis, including general health screening data, the Korea Central Cancer Registry, national insurance claims data, and cause of mortality from the National Statistical Office. To solicit the utility index of prostate cancer, a face-to-face interview for typical men aged 40 to 69 was conducted using a Time-Trade Off method. As a result, the increase of effectiveness was estimated to be very low, when adopting PSA screening, and the incremental cost effectiveness ratio (ICER) was analyzed as about 94 million KRW. Sensitivity analyses were performed on the incidence rate, screening rate, cancer stage distribution, utility index, and treatment costs but the results were consistent with the base analysis. Under Korean circumstances with a relatively low incidence rate of prostate cancer, PSA screening is not cost-effective. Therefore, we conclude that adopting national prostate cancer screening would not be beneficial until further evidence is provided in the future.

  7. The Interrelationship of Common Clinical Movement Screens: Establishing Population-Specific Norms in a Large Cohort of Military Applicants.

    PubMed

    de la Motte, Sarah J; Gribbin, Timothy C; Lisman, Peter; Beutler, Anthony I; Deuster, Patricia

    2016-11-01

     Musculoskeletal injuries (MSK-Is) are a leading cause of missed duty time and morbidity in the military. Modifiable risk factors for MSK-Is, such as inadequate core stability, poor movement patterns, and dynamic balance deficits, have not been identified in military applicants on entering service.  To establish normative functional movement data using a series of screens in military applicants entering basic training and explore relationships among several movement tests.  Cross-sectional study.  Military Entrance Processing Station.  A total of 1714 (1434 male, 280 female) military applicants entering the US Army (n = 546), Navy (n = 414), Air Force (n = 229), or Marine Corps (n = 525).  We conducted the Functional Movement Screen (FMS), Y-Balance Test (YBT), overhead squat (OHS), and Landing Error Scoring System (LESS). Movements were assessed using the scoring convention for each screen.  The FMS, YBT, OHS, and LESS scores and associations among the movement screens as well as clinical meaningfulness.  A total of 1037 of the 1714 enrolled applicants were screened on the day they left for basic training. Normative means for this population were established: FMS = 14.7 ± 1.8, YBT anterior-reach difference = 3.1 ± 3.0 cm, mean YBT composite differences = 8.0 ± 6.8 cm, mean YBT composite percentage = 90.9% ± 8.3%, OHS errors = 5.0 ± 2.8, and LESS score = 5.7 ± 2.1. Backward regression results revealed that the YBT composite percentage was related to the FMS and OHS scores in males and to the FMS and LESS results in females. However, clinically meaningful relationships between the tests varied for both males and females.  Sex-normative values for the FMS, YBT, OHS, and LESS screens were established for US military applicants, and some of the assessments overlapped. Overall, males performed better on the OHS and LESS and achieved a greater YBT composite percentage than females. The regression results revealed movement screen performance relationships that varied by sex and clinical meaningfulness. In future studies, we will determine if performance on any of the screens is associated with MSK-Is in basic trainees.

  8. Random plasma glucose in serendipitous screening for glucose intolerance: screening for impaired glucose tolerance study 2.

    PubMed

    Ziemer, David C; Kolm, Paul; Foster, Jovonne K; Weintraub, William S; Vaccarino, Viola; Rhee, Mary K; Varughese, Rincy M; Tsui, Circe W; Koch, David D; Twombly, Jennifer G; Narayan, K M Venkat; Phillips, Lawrence S

    2008-05-01

    With positive results from diabetes prevention studies, there is interest in convenient ways to incorporate screening for glucose intolerance into routine care and to limit the need for fasting diagnostic tests. The aim of this study is to determine whether random plasma glucose (RPG) could be used to screen for glucose intolerance. This is a cross-sectional study. The participants of this study include a voluntary sample of 990 adults not known to have diabetes. RPG was measured, and each subject had a 75-g oral glucose tolerance test several weeks later. Glucose intolerance targets included diabetes, impaired glucose tolerance (IGT), and impaired fasting glucose(110) (IFG(110); fasting glucose, 110-125 mg/dl, and 2 h glucose < 140 mg/dl). Screening performance was measured by area under receiver operating characteristic curves (AROC). Mean age was 48 years, and body mass index (BMI) was 30.4 kg/m(2); 66% were women, and 52% were black; 5.1% had previously unrecognized diabetes, and 24.0% had any "high-risk" glucose intolerance (diabetes or IGT or IFG(110)). The AROC was 0.80 (95% CI 0.74-0.86) for RPG to identify diabetes and 0.72 (0.68-0.75) to identify any glucose intolerance, both highly significant (p < 0.001). Screening performance was generally consistent at different times of the day, regardless of meal status, and across a range of risk factors such as age, BMI, high density lipoprotein cholesterol, triglycerides, and blood pressure. RPG values should be considered by health care providers to be an opportunistic initial screening test and used to prompt further evaluation of patients at risk of glucose intolerance. Such "serendipitous screening" could help to identify unrecognized diabetes and prediabetes.

  9. Assessment without Testing: Using Performance Measures Embedded in a Technology-Based Instructional Program as Indicators of Reading Ability

    ERIC Educational Resources Information Center

    Mitchell, Alison; Baron, Lauren; Macaruso, Paul

    2018-01-01

    Screening and monitoring student reading progress can be costly and time consuming. Assessment embedded within the context of online instructional programs can capture ongoing student performance data while limiting testing time outside of instruction. This paper presents two studies that examined the validity of using performance measures from a…

  10. [User's requests (from a practitioner's perspective)].

    PubMed

    Ohnishi, T

    1997-08-01

    As a practitioner, I have to rely on outside clinical laboratories and affiliated hospitals to perform laboratory tests. In this abstract, I describe specific problems I have encountered with third-party laboratories, and propose solutions for these problems to optimize use of laboratory tests. BLOOD TESTS: The most frequent problem in ordering blood tests is the lack of detailed information regarding sampling conditions. I often have to call laboratories to check whether the sample should be serum or plasma, what volume is needed, whether the sample should be cooled, etc. I propose that clinical laboratories should provide practitioners' manuals that describe specific sampling information. Most laboratories do not keep the data from ultrasonographic tests. The lack of these is most problematic when test results are interpreted differently by laboratories and by practitioners. Retaining the data would also help private laboratories improve the quality of the test by enabling them to compare their interpretations with others'. ANNUAL MEDICAL SCREENING: Even if an abnormal finding is detected at medical screening clinics, the final diagnosis is usually not sent back to the screening facilities. This is highly recommended to establish an official system that mediates the feedback to screening centers. MRI: Due to miscommunication between practitioners and radiologists, the test is sometimes performed inappropriately. A thorough consultation should occur before the test to clarify specific goals for each patient. PATHOLOGICAL TESTS: Interpretation of results is often inconsistent among laboratories. Independent clinical laboratories tend to report results without indicating sample problems, while pathology departments at affiliated hospitals tend to emphasize sample problems instead of diagnosis or suggesting ways to improve sample quality. Mutual communication among laboratories would help standardize the quality of pathological tests.

  11. A novel metric that quantifies risk stratification for evaluating diagnostic tests: The example of evaluating cervical-cancer screening tests across populations.

    PubMed

    Katki, Hormuzd A; Schiffman, Mark

    2018-05-01

    Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.

  12. An open-label randomized-controlled trial of low dose aspirin with an early screening test for pre-eclampsia and growth restriction (TEST): Trial protocol.

    PubMed

    Mone, Fionnuala; Mulcahy, Cecilia; McParland, Peter; Stanton, Alice; Culliton, Marie; Downey, Paul; McCormack, Dorothy; Tully, Elizabeth; Dicker, Patrick; Breathnach, Fionnuala; Malone, Fergal D; McAuliffe, Fionnuala M

    2016-07-01

    Pre-eclampsia remains a worldwide cause of maternal and perinatal morbidity and mortality. Low dose aspirin (LDA) can reduce the occurrence of pre-eclampsia in women with identifiable risk factors. Emerging screening tests can determine the maternal risk of developing placental disease, such as pre-eclampsia from the first trimester of pregnancy. The aim of this study is to determine if it is more beneficial in terms of efficacy and acceptability to routinely prescribe LDA to nulliparous low-risk women compared to test indicated LDA on the basis of a positive screening test for placental disease. We propose a three armed multi-center open-labeled randomized control trial of; (i) routine LDA, (ii) no aspirin, and (iii) LDA on the basis of a positive first trimester pre-eclampsia screening test. LDA (75mg once daily) shall be given from the first trimester until 36-week gestation. The primary outcome measures include; (i) the proportion of eligible women that agree to participate (acceptability), (ii) compliance with study protocol (acceptability and feasibility), (iii) the proportion of women in whom it is possible to obtain first trimester trans-abdominal uterine artery Doppler examination (feasibility) and (iv) the proportion of women with a completed screening test that are issued the screening result within one week of having the test performed (feasibility). This will be the first clinical trial to determine the efficacy and acceptability in low-risk women of taking routine LDA versus no aspirin versus LDA based on a positive first trimester screening test for the prevention of placental disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. On-site drugs of abuse urinary screening tests for the management of opiate-addicted patients: a survey among French general practitioners.

    PubMed

    Dupouy, Julie; Bismuth, Serge; Oustric, Stéphane; Lapeyre-Mestre, Maryse

    2012-01-01

    In France, opiate-addicted patients are mainly managed by general practitioners (GPs). Because on-site abuse drugs urinary screening tests (ODUTs) are now on the market, we investigated French GPs' knowledge and practices concerning drug tests with a focus on ODUTs. We conducted a descriptive cross-sectional study in ambulatory practice. Postal questionnaires were sent to a random sample of GPs in the Midi-Pyrénées area of France in December 2009. Of the 482 GPs in the sample, 116 (24.1%) regularly treated opiate- addicted patients. Only 31 of them (26.7%) used drug tests and 4 of them (3.4%) performed ODUTs in their consultation rooms. Most of the GPs did not perform ODUTs because they were unaware of whether such tests were reliable or available. Many French GPs treating opiate-addicted patients regularly did not perform ODUTs and lacked knowledge of them. Copyright © 2012 S. Karger AG, Basel.

  14. Performance of a Cartridge-Based Assay for Detection of Clinically Significant Human Papillomavirus (HPV) Infection: Lessons from VALGENT (Validation of HPV Genotyping Tests)

    PubMed Central

    Geraets, Daan; Cuzick, Jack; Cadman, Louise; Moore, Catherine; Vanden Broeck, Davy; Padalko, Elisaveta; Quint, Wim; Arbyn, Marc

    2016-01-01

    The Validation of Human Papillomavirus (HPV) Genotyping Tests (VALGENT) studies offer an opportunity to clinically validate HPV assays for use in primary screening for cervical cancer and also provide a framework for the comparison of analytical and type-specific performance. Through VALGENT, we assessed the performance of the cartridge-based Xpert HPV assay (Xpert HPV), which detects 14 high-risk (HR) types and resolves HPV16 and HPV18/45. Samples from women attending the United Kingdom cervical screening program enriched with cytologically abnormal samples were collated. All had been previously tested by a clinically validated standard comparator test (SCT), the GP5+/6+ enzyme immunoassay (EIA). The clinical sensitivity and specificity of the Xpert HPV for the detection of cervical intraepithelial neoplasia grade 2 or higher (CIN2+) and CIN3+ relative to those of the SCT were assessed as were the inter- and intralaboratory reproducibilities according to international criteria for test validation. Type concordance for HPV16 and HPV18/45 between the Xpert HPV and the SCT was also analyzed. The Xpert HPV detected 94% of CIN2+ and 98% of CIN3+ lesions among all screened women and 90% of CIN2+ and 96% of CIN3+ lesions in women 30 years and older. The specificity for CIN1 or less (≤CIN1) was 83% (95% confidence interval [CI], 80 to 85%) in all women and 88% (95% CI, 86 to 91%) in women 30 years and older. Inter- and intralaboratory agreements for the Xpert HPV were 98% and 97%, respectively. The kappa agreements for HPV16 and HPV18/45 between the clinically validated reference test (GP5+/6+ LMNX) and the Xpert HPV were 0.92 and 0.91, respectively. The clinical performance and reproducibility of the Xpert HPV are comparable to those of well-established HPV assays and fulfill the criteria for use in primary cervical cancer screening. PMID:27385707

  15. Using educational outreach and a financial incentive to increase general practices’ contribution to chlamydia screening in South-East London 2003–2011

    PubMed Central

    2012-01-01

    Background The London Boroughs of Lambeth and Southwark have high levels of sexually transmitted infections including Chlamydia trachomatis. Modelling studies suggest that reductions in the prevalence of chlamydia infection will require a high level of population screening coverage and positivity among those screened. General practice has a potentially important role to play in delivering these levels of coverage since large numbers (up to 60%) of young people visit their general practice every year but previous work suggests that there are barriers to delivering screening in this setting. The aim of this study was to evaluate an intervention to increase chlamydia screening in general practice within Primary Care Trusts (PCTs) of Lambeth and Southwark, a strategy combining financial incentives and supportive practice visits to raise awareness and solve problems. Methods Data on age, gender, venue and chlamydia result for tests on under 25 s in Lambeth from 2003–11 was obtained from the National Chlamydia Screening Programme. We analysed the number and percentage of tests generated in general practice, and looked at the number of practices screening more than 10% of their practice cohort of 15–24 year olds, male/female ratio and positivity rates across other screening venues. We also looked at practices screening less than 10% and studied change over time. We compared data from Lambeth and Southwark with London and England. We also studied features of the level and type of educational and financial incentive interventions employed. Results Chlamydia tests performed in general practice increased from 23 tests in 2003–4 to 4813 tests in 2010–11 in Lambeth. In Southwark they increased from 5 tests in 2003/04 to 4321 in 2010/11. In 2011, 44.6% of tests came from GPs in Lambeth and 46% from GP’s in Southwark. In Lambeth 62.7% of practices tested more than 10% of their cohort and in Southwark this was 55.8%. In Lambeth, postivity rate in 2010/11 was 5.8% in men and 6.0% in women. In Southwark positivity rate was 3.9% in men and 5.3% in women. In 2003/04 13% tests in general practice (Lambeth) were from men, this increased to 25% in 2010/11. In Southwark this increased from 20% in 2003/04 to 27.6% in 2010/11. We compared the results with London and national data and showed significant differences between GP testing in Lambeth and Southwark, and GP testing in London and the rest of England. Conclusions General practices can be important potential providers of chlamydia tests. With a combination of sustained support, financial incentives and feedback on performance, general practice may be able to test a large percentage of 15–24 year olds. General practice is also a potentially important provider of chlamydia tests to young men. PMID:22984897

  16. Pathology consultation on urine compliance testing and drug abuse screening.

    PubMed

    Ward, Michael B; Hackenmueller, Sarah A; Strathmann, Frederick G

    2014-11-01

    Compliance testing in pain management requires a distinct approach compared with classic clinical toxicology testing. Differences in the patient populations and clinical expectations require modifications to established reporting cutoffs, assay performance expectations, and critical review of how best to apply the available testing methods. Although other approaches to testing are emerging, immunoassay screening followed by mass spectrometry confirmation remains the most common testing workflow for pain management compliance and drug abuse testing. A case-based approach was used to illustrate the complexities inherent to and uniqueness of pain management compliance testing for both clinicians and laboratories. A basic understanding of the inherent strengths and weaknesses of immunoassays and mass spectrometry provides the clinician a better understanding of how best to approach pain management compliance testing. Pain management compliance testing is a textbook example of an emerging field requiring open communication between physician and performing laboratory to fully optimize patient care. Copyright© by the American Society for Clinical Pathology.

  17. Knowledge of Surgery-Related Allergic Contact Dermatitis among Florida Dermatological Surgeons

    PubMed Central

    Rouhani, Panta; Kirsner, Robert S.; Amado, Antoine; Fleming, Lora E.; Nouri, Keyvan

    2009-01-01

    Objective. To assess knowledge base and practice habits of dermatological surgeons regarding surgery-related allergic contact dermatitis. Design. Cross-sectional study. Setting. The Florida Society of Dermatologic Surgery served as the study group. Participants. Cohort of dermatological surgeons. Measurements. An anonymous, close-ended survey instrument eliciting common surgical practices as well as allergic contact dermatitis knowledge. Results. Among the 45 respondents, 87 percent reported performing surgery more than 10 times per week and only 14 percent of respondents reported using latex-free gloves in their practice. Nearly two-thirds (66%) of respondents reported diagnosing allergic contact dermatitis either among themselves, their surgical staff, and/or patients. Surgeons were noted to use the TRUE Test® to screen for adhesive allergy. While colophony can be found both in adhesive products and on the TRUE Test, the main adhesives found in perisurgical products, acrylates, cannot. Similarly, the TRUE Test does not screen for antiseptics, yet this group of respondents suspected antiseptics nearly one-fourth of the time and used the TRUE Test to screen for them. Lastly, six dermatological surgeons used the TRUE Test to screen for suture allergy. While only two used chromated cat gut (the TRUE Test screens for chromium), the other surgical components are not screened. Conclusion. Education among dermatological surgeons is needed regarding exposure to a potential allergen in the surgical setting and risk of developing allergic contact dermatitis. PMID:20725578

  18. Cytology and human papillomavirus testing 6 to 12 months after ASCUS or LSIL cytology in organized screening to predict high-grade cervical neoplasia between screening rounds.

    PubMed

    Tropé, Ameli; Sjøborg, Katrine D; Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Alfsen, G Cecilie; Jonassen, Christine M

    2012-06-01

    We carried out a prospective study comparing the performance of human papillomavirus (HPV) E6/E7 mRNA (PreTect HPV-Proofer; NorChip, Klokkarstua, Norway) and DNA (Amplicor HPV test; Roche Diagnostics, Basel, Switzerland) triage testing of women 6 to 12 months after atypical-squamous-cells-of-undetermined-significance (ASCUS) or low-grade-squamous-intraepithelial-lesion (LSIL) cytology in organized screening to predict high-grade cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) between screening rounds. Between January 2005 and April 2008, 692 study women with screening-detected ASCUS/LSIL cytology 6 to 12 months earlier returned for HPV mRNA and DNA testing and repeat cytology. The median follow-up time was 3 years, using existing health care facilities. Follow-up test results were available for 625 women. Of the 145 CIN2+ cases detected during the study period, 95 (65.5%) were HPV mRNA positive 6 to 12 months after screening-detected ASCUS/LSIL, 44 (30.4%) were HPV mRNA negative, and 6 (4.1%) were invalid. The corresponding HPV DNA results were 139 (95.9%), 5 (3.4%), and 1 (0.7%), respectively. The cumulative incidences of CIN2+ 3 years after a negative HPV mRNA and DNA test were 10.3% (95% confidence interval [CI], 7.2 to 13.3%) and 1.8% (95% CI, 0.0 to 3.6%), respectively. The cumulative incidences of CIN2+ 3 years after positive HPV mRNA and DNA tests were 52.8% (95% CI, 40.1 to 60.1%) and 41.3% (95% CI, 35.5 to 46.6%), respectively. In conclusion, both positive HPV mRNA and DNA test results have a high enough long-term prediction of CIN2+ risk to consider referral to colposcopy as good practice when performed in delayed triage of women with ASCUS/LSIL cytology. In addition, the low CIN2+ risk among women with a negative Amplicor HPV test in our study confirms its safe use in a clinical setting.

  19. Cytology and Human Papillomavirus Testing 6 to 12 Months after ASCUS or LSIL Cytology in Organized Screening To Predict High-Grade Cervical Neoplasia between Screening Rounds

    PubMed Central

    Sjøborg, Katrine D.; Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Alfsen, G. Cecilie; Jonassen, Christine M.

    2012-01-01

    We carried out a prospective study comparing the performance of human papillomavirus (HPV) E6/E7 mRNA (PreTect HPV-Proofer; NorChip, Klokkarstua, Norway) and DNA (Amplicor HPV test; Roche Diagnostics, Basel, Switzerland) triage testing of women 6 to 12 months after atypical-squamous-cells-of-undetermined-significance (ASCUS) or low-grade-squamous-intraepithelial-lesion (LSIL) cytology in organized screening to predict high-grade cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) between screening rounds. Between January 2005 and April 2008, 692 study women with screening-detected ASCUS/LSIL cytology 6 to 12 months earlier returned for HPV mRNA and DNA testing and repeat cytology. The median follow-up time was 3 years, using existing health care facilities. Follow-up test results were available for 625 women. Of the 145 CIN2+ cases detected during the study period, 95 (65.5%) were HPV mRNA positive 6 to 12 months after screening-detected ASCUS/LSIL, 44 (30.4%) were HPV mRNA negative, and 6 (4.1%) were invalid. The corresponding HPV DNA results were 139 (95.9%), 5 (3.4%), and 1 (0.7%), respectively. The cumulative incidences of CIN2+ 3 years after a negative HPV mRNA and DNA test were 10.3% (95% confidence interval [CI], 7.2 to 13.3%) and 1.8% (95% CI, 0.0 to 3.6%), respectively. The cumulative incidences of CIN2+ 3 years after positive HPV mRNA and DNA tests were 52.8% (95% CI, 40.1 to 60.1%) and 41.3% (95% CI, 35.5 to 46.6%), respectively. In conclusion, both positive HPV mRNA and DNA test results have a high enough long-term prediction of CIN2+ risk to consider referral to colposcopy as good practice when performed in delayed triage of women with ASCUS/LSIL cytology. In addition, the low CIN2+ risk among women with a negative Amplicor HPV test in our study confirms its safe use in a clinical setting. PMID:22518869

  20. Nucleic Acid Amplification Test For Detection Of West Nile Virus Infection In Pakistani Blood Donors.

    PubMed

    Niazi, Saifullah Khan; Alam, Maqbool; Yazdani, Muhammad Sajid; Ghani, Eijaz; Rathore, Muhammad Ali

    2017-01-01

    The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18-57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples.

  1. The relative utility of the autologous control and the antiglobulin test phase of the crossmatch.

    PubMed

    Perkins, J T; Arruza, M; Fong, K; Sosler, S D; Saporito, C

    1990-01-01

    A retrospective study of pretransfusion testing records compared the utility of the antiglobulin test (AGT) phase of the crossmatch and the autologous control (autocontrol) for detecting clinically significant alloimmunization to red cells (RBCs). Of 110,780 consecutive crossmatches, 141 were positive after a negative antibody screening test; only 4 of these were due to alloantibodies of potential clinical significance, for a predictive value of a positive AGT crossmatch, after a negative antibody screen, of 2.8 percent (4/141). The frequency of potentially shortened RBC survival was 1 in 27,685 units crossmatched. During a similar period, 56,090 autocontrols were performed with the antibody screen. The autocontrol was positive on 902 samples in which the antibody screen was negative. Antibody identification performed in 684 cases generally yielded only cold or warm autoagglutinins. In 96 cases, some form of alloantibody was detected, but only 25 had potential clinical significance by our criteria. Eight of these alloantibodies had concurrently caused in vivo sensitization of RBCs and were classified as delayed hemolytic transfusion reactions. The predictive value of the autocontrol, calculated as the number of significant alloantibodies detected in autocontrol-positive, antibody-screen-negative samples, was 3.6 percent (25/684). Inspection of these cases revealed 11 in which shortened RBC survival might have resulted if the serologic abnormality had not been detected. Thus, the autocontrol had a slightly greater yield of clinically significant findings than the AGT crossmatch.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Setting visual pre-placement testing in a technology manufacturing environment.

    PubMed

    Gowan, Nancy J

    2014-01-01

    Every day we use our eyes to perform activities of daily living and work. Aging changes as well as health conditions can impact an individual's visual function, making it more difficult to accurately perform work activities. Occupational therapists work closely with optometrists and employers to develop ways to accommodate for these changes so that the employee can continue to perform the work tasks. This manuscript outlines a case study of systematically developing visual demands analyses and pre-placement vision screening assessment protocols for individuals completing quality inspection positions. When the vision screening was completed, it was discovered that over 20% of the employees had visual deficits that were correctable. This screening process yielded improved quality results but also identification of previously undetected visual deficits. Further development of vision screening in the workplace is supported.

  3. Verification testing of the compression performance of the HEVC screen content coding extensions

    NASA Astrophysics Data System (ADS)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  4. [Targeted newborn screening for sickle-cell anemia: Sickling test (Emmel test) boundaries in the prenatal assessment in West African area].

    PubMed

    Diallo, D A; Guindo, A; Touré, B A; Sarro, Y S; Sima, M; Tessougué, O; Baraika, M A; Guindo, P; Traoré, M; Diallo, M; Dorie, A

    2018-05-01

    Newborn screening for sickle cell anemia is necessary in Africa where the disease is more frequent. Hemoglobin electrophoresis is used for screening, but is limited by a high cost and difficult access. Sickling test (Emmel test), which is more affordable and technically more accessible, is often requested for prenatal assessment of pregnant women in West African areas to reserve screening for newborns from mothers in whom the positive sickling test attests the presence of hemoglobin S. This study aims to evaluate the number of undetected sickle cell anemia newborns by a screening policy targeting only newborns from mothers in whom a sickling test would have been positive. From 2010 to 2012, in Bamako, Mali, West Africa, 2489 newborns were routinely screened for sickle cell anemia at the umbilical cord or heel by isoelectrofocusing and, if necessary, by high-performance liquid chromatography. These newborns were born from 2420 mothers whose hemoglobin was studied by isoelectrofocusing. The data was recorded and processed using Excel software version 14.0.0. We calculated the frequency of the sickle cell gene in mothers and newborns as well as the number of SCA newborns from heterozygous or C homozygous mothers. Of the 2489 newborns, 16 had sickle cell anemia (6 SS and 10 SC); 198 had the sickle cell trait; 139 were AC and 1 was CC. Of the 10 newborns with SC profile, 3 were born from mothers not carrying the S gene but the C gene of hemoglobin and in which an Emmel test would have been negative. Targeted newborn screening, based on the results of sickling test in pregnant women, would misdiagnose more than one of six sickle cell anemia newborns who would not benefit from early care. Cost-effectiveness studies of routine newborn screening for sickle cell anemia should lead to a better screening strategy in contexts where hemoglobin S and other hemoglobin defect genes coexist. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. [SCREENING OF NUTRITIONAL STATUS AMONG ELDERLY PEOPLE AT FAMILY MEDICINE].

    PubMed

    Račić, M; Ivković, N; Kusmuk, S

    2015-11-01

    The prevalence of malnutrition in elderly is high. Malnutrition or risk of malnutrition can be detected by use of nutritional screening or assessment tools. This systematic review aimed to identify tools that would be reliable, valid, sensitive and specific for nutritional status screening in patients older than 65 at family medicine. The review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Studies were retrieved using MEDLINE (via Ovid), PubMed and Cochrane Library electronic databases and by manual searching of relevant articles listed in reference list of key publications. The electronic databases were searched using defined key words adapted to each database and using MESH terms. Manual revision of reviews and original articles was performed using Electronic Journals Library. Included studies involved development and validation of screening tools in the community-dwelling elderly population. The tools, subjected to validity and reliability testing for use in the community-dwelling elderly population were Mini Nutritional Assessment (MNA), Mini Nutritional Assessment-Short Form (MNA-SF), Nutrition Screening Initiative (NSI), which includes DETERMINE list, Level I and II Screen, Seniors in the Community: Risk Evaluation for Eating, and Nutrition (SCREEN I and SCREEN II), Subjective Global Assessment (SGA), Nutritional Risk Index (NRI), and Malaysian and South African tool. MNA and MNA-SF appear to have highest reliability and validity for screening of community-dwelling elderly, while the reliability and validity of SCREEN II are good. The authors conclude that whilst several tools have been developed, most have not undergone extensive testing to demonstrate their ability to identify nutritional risk. MNA and MNA-SF have the highest reliability and validity for screening of nutritional status in the community-dwelling elderly, and the reliability and validity of SCREEN II are satisfactory. These instruments also contain all three nutritional status indicators and are practical for use in family medicine. However, the gold standard for screening cannot be set because testing of reliability and continuous validation in the study with a higher level of evidence need to be conducted in family medicine.

  6. Effect of Several Negative Rounds of Human Papillomavirus and Cytology Co-testing on Safety Against Cervical Cancer: An Observational Cohort Study.

    PubMed

    Castle, Philip E; Kinney, Walter K; Xue, Xiaonan; Cheung, Li C; Gage, Julia C; Zhao, Fang-Hui; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas S; Wentzensen, Nicolas; Katki, Hormuzd A; Schiffman, Mark

    2018-01-02

    Current U.S. cervical cancer screening and management guidelines do not consider previous screening history, because data on multiple-round human papillomavirus (HPV) and cytology "co-testing" have been unavailable. To measure cervical cancer risk in routine practice after successive negative screening co-tests at 3-year intervals. Observational cohort study. Integrated health care system (Kaiser Permanente Northern California, Oakland, California). 990 013 women who had 1 or more co-tests from 2003 to 2014. 3- and 5-year cumulative detection of (risk for) cervical intraepithelial neoplasia grade 3, adenocarcinoma in situ, and cervical cancer (≥CIN3) in women with different numbers of negative co-tests, overall and within subgroups defined by previous co-test results or baseline age. Five-year ≥CIN3 risks decreased after each successive negative co-test screening round (0.098%, 0.052%, and 0.035%). Five-year ≥CIN3 risks for an HPV-negative co-test, regardless of the cytology result, nearly matched the performance (reassurance) of a negative co-test for each successive round of screening (0.114%, 0.061%, and 0.041%). By comparison, ≥CIN3 risks for the cytology-negative co-test, regardless of the HPV result, also decreased with each successive round, but 3-year risks were as high as 5-year risks after an HPV-negative co-test (0.199%, 0.065%, and 0.043%). No interval cervical cancer cases were diagnosed after the second negative co-test. Independently, ≥CIN3 risks decreased with age. Length of previous screening interval did not influence future ≥CIN3 risks. Interval-censored observational data. After 1 or more negative cervical co-tests (or HPV tests), longer screening intervals (every 5 years or more) might be feasible and safe. National Cancer Institute Intramural Research Program.

  7. Physical phenomena in mercury ion thrusters

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1979-01-01

    Experimental tests results demonstrating that reductions in screen grid thickness enhance the performance of ion thruster grids are presented. Shaping of the screen hole cross section is shown on the other hand not to affect performance substantially. The effect of the magnetic field in the vicinity of the hollow cathode on cathode performance is studied and test results are presented that show reductions in keeper voltages of a few volts can be realized by judicious applications of fields on the order of 100 gauss. The plasma downstream of a SERT 2 thruster operating without high voltage is studied. A model describing electron escape from the thruster under these conditions is discussed. A model defining the performance of the baffle aperture of an ion thruster is refined and experimental verification of the model is undertaken.

  8. Reproducibility of risk figures in 2nd-trimester maternal serum screening for down syndrome: comparison of 2 laboratories.

    PubMed

    Benn, Peter A; Makowski, Gregory S; Egan, James F X; Wright, Dave

    2006-11-01

    Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.

  9. Environmental Test Screening Procedure

    NASA Technical Reports Server (NTRS)

    Zeidler, Janet

    2000-01-01

    This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

  10. Responsible implementation of expanded carrier screening

    PubMed Central

    Henneman, Lidewij; Borry, Pascal; Chokoshvili, Davit; Cornel, Martina C; van El, Carla G; Forzano, Francesca; Hall, Alison; Howard, Heidi C; Janssens, Sandra; Kayserili, Hülya; Lakeman, Phillis; Lucassen, Anneke; Metcalfe, Sylvia A; Vidmar, Lovro; de Wert, Guido; Dondorp, Wybo J; Peterlin, Borut

    2016-01-01

    This document of the European Society of Human Genetics contains recommendations regarding responsible implementation of expanded carrier screening. Carrier screening is defined here as the detection of carrier status of recessive diseases in couples or persons who do not have an a priori increased risk of being a carrier based on their or their partners' personal or family history. Expanded carrier screening offers carrier screening for multiple autosomal and X-linked recessive disorders, facilitated by new genetic testing technologies, and allows testing of individuals regardless of ancestry or geographic origin. Carrier screening aims to identify couples who have an increased risk of having an affected child in order to facilitate informed reproductive decision making. In previous decades, carrier screening was typically performed for one or few relatively common recessive disorders associated with significant morbidity, reduced life-expectancy and often because of a considerable higher carrier frequency in a specific population for certain diseases. New genetic testing technologies enable the expansion of screening to multiple conditions, genes or sequence variants. Expanded carrier screening panels that have been introduced to date have been advertised and offered to health care professionals and the public on a commercial basis. This document discusses the challenges that expanded carrier screening might pose in the context of the lessons learnt from decades of population-based carrier screening and in the context of existing screening criteria. It aims to contribute to the public and professional discussion and to arrive at better clinical and laboratory practice guidelines. PMID:26980105

  11. Patient education for colon cancer screening: a randomized trial of a video mailed before a physical examination.

    PubMed

    Zapka, Jane G; Lemon, Stephenie C; Puleo, Elaine; Estabrook, Barbara; Luckmann, Roger; Erban, Stephen

    2004-11-02

    Colorectal cancer screening is underused, and primary care clinicians are challenged to provide patient education within the constraints of busy practices. To test the effect of an educational video, mailed to patients' homes before a physical examination, on performance of colorectal cancer screening, particularly sigmoidoscopy. Randomized, controlled trial. 5 primary care practices in central Massachusetts. 938 patients age 50 to 74 years who were scheduled for an upcoming physical examination, had no personal history of colorectal cancer, and were eligible for lower-endoscopy screening according to current guidelines. Participants were randomly assigned to receive usual care (n = 488) or a video about colorectal cancer, the importance of early detection, and screening options (n = 450). Baseline and 6-month follow-up telephone assessments were conducted. A dependent variable classified screening since baseline as 1) sigmoidoscopy with or without other tests, 2) another test or test combination, or 3) no tests. Overall screening rates were the same in the intervention and control groups (55%). In regression modeling, intervention participants were nonsignificantly more likely to complete sigmoidoscopy alone or in combination with another test (odds ratio, 1.22 [95% CI, 0.88 to 1.70]). Intervention dose (viewing at least half of the video) was significantly related to receiving sigmoidoscopy with or without another test (odds ratio, 2.81 [CI, 1.85 to 4.26]). Recruitment records showed that at least 23% of people coming for periodic health assessments were currently screened by a lower-endoscopy procedure and therefore were not eligible. The primary care sample studied consisted primarily of middle-class white persons who had high screening rates at baseline. The results may not be generalizable to other populations. The trial was conducted during a period of increased health insurance coverage for lower-endoscopy procedures and public media attention to colon cancer screening. A mailed video had no effect on the overall rate of colorectal cancer screening and only modestly improved sigmoidoscopy screening rates among patients in primary care practices.

  12. Fecal Immunochemical Test (FIT) for Colon Cancer Screening: Variable Performance with Ambient Temperature

    PubMed Central

    Doubeni, Chyke A.; Jensen, Christopher D.; Fedewa, Stacey A.; Quinn, Virginia P.; Zauber, Ann G.; Schottinger, Joanne E.; Corley, Douglas A.; Levin, Theodore R.

    2017-01-01

    Introduction Fecal immunochemical tests (FITs) are widely used in colorectal cancer (CRC) screening, but hemoglobin degradation, due to exposure of the collected sample to high temperatures, could reduce test sensitivity. We examined the relation of ambient temperature exposure with FIT positivity rate and sensitivity. Methods This was a retrospective cohort study of patients 50 to 75 years in Kaiser Permanente Northern California’s CRC screening program, which began mailing FIT kits annually to screen-eligible members in 2007. Primary outcomes were FIT positivity rate and sensitivity to detect CRC. Predictors were month, season, and daily ambient temperatures of test result dates based on US National Oceanic and Atmospheric Administration data. Results Patients (n =472,542) completed 1,141,162 FITs. Weekly test positivity rate ranged from 2.6% to 8.0% (median, 4.4%) and varied significantly by month (June/July vs December/January rate ratio [RR] =0.79, 95% confidence interval [CI], 0.76 to 0.83) and season. FIT sensitivity was lower in June/July (74.5%; 95% CI, 72.5 to 76.6) than January/December (78.9%; 95% CI, 77.0 to 80.7). Conclusions FITs completed during high ambient temperatures had lower positivity rates and lower sensitivity. Changing kit design, specimen transportation practices, or avoiding periods of high ambient temperatures may help optimize FIT performance, but may also increase testing complexity and reduce patient adherence, requiring careful study. PMID:28076249

  13. Fasting capillary blood glucose: an appropriate measurement in screening for diabetes and pre-diabetes in low-resource rural settings.

    PubMed

    Zhao, X; Zhao, W; Zhang, H; Li, J; Shu, Y; Li, S; Cai, L; Zhou, J; Li, Y; Hu, R

    2013-01-01

    To evaluate the efficiency of fasting capillary blood glucose (FCG) measurement as compared with fasting venous plasma glucose (FPG) measurement in screening diabetes and pre-diabetes in low-resource rural settings. In 2010, 993 participants were randomly selected from 9 villages in Yunnan province using cluster sampling method. Samples for FCG and FPG test were obtained after demographics and physical examination. The oral glucose tolerance test was performed in parallel as gold standard for diagnosis. Diagnostic capacities of the FCG measurement in predicting undiagnosed diabetes and pre-diabetes were assessed. The performance of FCG and FPG tests was compared. Fifty-seven individuals with undiagnosed diabetes and 145 subjects with pre-diabetes were detected. The concordance between FCG and FPG levels was high (r = 0.75, p < 0.001). The area under the curve (AUC) for FCG test in predicting diabetes was 0.88 [95% confidence interval (CI) 0.82-0.93] with the optimal cutoff value of 5.65 mmol/l, sensitivity of 84.2%, and specificity of 79.3%. The corresponding values in FPG tests were 0.92 (95% CI 0.88-0.97) (AUC), 6.51 mmol/l (optimal cutoff point), 82.5% (sensitivity) and 98.3% (specificity), respectively. No significant difference was found in the AUC for the two screening strategies. FCG measurement is considered to be a convenient, practicable screening method in low-resource rural communities with acceptable test properties.

  14. [Strategy for molecular testing in pulmonary carcinoma].

    PubMed

    Penault-Llorca, Frédérique; Tixier, Lucie; Perrot, Loïc; Cayre, Anne

    2016-01-01

    Nowadays, the analysis of theranostic molecular markers is central in the management of lung cancer. As those tumors are diagnosed in two third of the cases at an advanced stage, molecular screening is frequently performed on "small samples". The screening strategy starts by an accurate histopathological characterization, including on biopsies or cytological specimens. WHO 2015 provided a new classification for small biopsy and cytology, defining categories such as non-small cell carcinoma (NSCC), favor adenocarcinoma (TTF1 positive), or favor squamous cell carcinoma (p40 positive). Only the NSCC tumors, non-squamous, are eligible to molecular testing. A strategy aiming at tissue sparing for the small biopsies has to be organized. Tests corresponding to available drugs are prioritized. Blank slides will be prepared for immunohistochemistry and in situ hybridization based tests such as ALK. DNA will then be extracted for the other tests, EGFR mutation screening first associated or not to KRAS. Then, the emerging biomarkers (HER2, ROS1, RET, BRAF…) as well as potentially other markers in case of clinical trials, can been tested. The spread of next generation sequencing technologies, with a very sensitive all-in-one approach will allow the identification of minority clones. Eventually, the development of liquid biopsies will provide the opportunity to monitor the apparition of resistance clones during treatment. This non-invasive approach allows patients with a contraindication to perform biopsy or with non-relevant biopsies to access to molecular screening. Copyright © 2016. Published by Elsevier Masson SAS.

  15. Technical standards and guidelines: prenatal screening for Down syndrome that includes first-trimester biochemistry and/or ultrasound measurements.

    PubMed

    Palomaki, Glenn E; Lee, Jo Ellen S; Canick, Jacob A; McDowell, Geraldine A; Donnenfeld, Alan E

    2009-09-01

    This statement is intended to augment the current general ACMG Standards and Guidelines for Clinical Genetics Laboratories and to address guidelines specific to first-trimester screening for Down syndrome. The aim is to provide the laboratory the necessary information to ensure accurate and reliable Down syndrome screening results given a screening protocol (e.g., combined first trimester and integrated testing). Information about various test combinations and their expected performance are provided, but other issues such as availability of reagents, patient interest in early test results, access to open neural tube defect screening, and availability of chorionic villus sampling are all contextual factors in deciding which screening protocol(s) will be selected by individual health care providers. Individual laboratories are responsible for meeting the quality assurance standards described by the Clinical Laboratory Improvement Act, the College of American Pathologists, and other regulatory agencies, with respect to appropriate sample documentation, assay validation, general proficiency, and quality control measures. These guidelines address first-trimester screening that includes ultrasound measurement and interpretation of nuchal translucency thickness and protocols that combine markers from both the first and second trimesters. Laboratories can use their professional judgment to make modification or additions.

  16. Screening for Chlamydial Cervicitis in a Sexually Active University Population.

    ERIC Educational Resources Information Center

    Malotte, C. Kevin; And Others

    1990-01-01

    Enzyme-linked immunoabsorbent assays to detect chlamydial cervicitis were performed on samples from 1,320 sexually active university women. Seventy-five had positive tests. Demographic, history, symptom, and physical examination variables were insufficient to predict infection accurately. Concludes that screening during routine visits with this…

  17. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    PubMed

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  18. Evaluation of Immigrant Tuberculosis Screening in Industrialized Countries

    PubMed Central

    Pareek, Manish; Baussano, Iacopo; Abubakar, Ibrahim; Dye, Christopher

    2012-01-01

    In industrialized countries, tuberculosis (TB) cases are concentrated among immigrants and driven by reactivation of imported latent TB infection (LTBI). We examined mechanisms used to screen immigrants for TB and LTBI by sending an anonymous, 18-point questionnaire to 31 member countries of the Organisation for Economic Co-operation and Development. Twenty-nine (93.5%) of 31 responded; 25 (86.2%) screened immigrants for active TB. Fewer countries (16/29, 55.2%) screened for LTBI. Marked variations were observed in targeted populations for age (range <5 years of age to all age groups) and TB incidence in countries of origin of immigrants (>20 cases/100,000 population to >500 cases/100,000). LTBI screening was conducted in 11/16 countries by using the tuberculin skin test. Six countries used interferon-γ release assays, primarily to confirm positive tuberculin skin test results. Industrialized countries performed LTBI screening infrequently and policies varied widely. There is an urgent need to define the cost-effectiveness of LTBI screening strategies for immigrants. PMID:22931959

  19. The Effects of Training on Knowledge and Beliefs About Breast Cancer and Early Diagnosis Methods Among Women.

    PubMed

    Yılmaz, Meryem; Sayın, Yazile; Cengiz, Hatice Öner

    2017-10-01

    Breast cancer (BC) is the most common female malignancy in the world and Turkey. Its prevalence and mortality are surprisingly increasing at a rapid rate. The objective of this study was to determine the effectiveness of training sessions on women's knowledge of relevant risk factors of BC and screening methods, screening behaviors and health beliefs among of healthy women in Turkey. In this study, in order to establish the efficiency of BC training, a semi-empirical single group pre-test & post-test research model was used. The data were collected by using a self-administered questionnaire and by using the Turkish version of Champion's health belief model scale (CHBMS). The pre-test was performed before the training and after one week of the training, post-test was performed with a questionnaire having the same content. In total, 244 women participated in the study. The average age of the women was 39.44 (SD=1.06) years. The mean total knowledge score increased significantly (p<.001) from 9.05 in the pre-test to 16.53 in the post-test. The results showed that both mean knowledge scores and CHBMS subscales scores of the women were increased significantly (p<.001) from the pre-test to the post-test. In multiple linear regression analysis, BC screening knowledge of women with susceptibility, benefit, self-efficacy and health motivation subscales of CHBMS, breast self-examination (BSE) practice and self-efficacy were also significant in the post-test; in the pre- and post-tests, a significant relationship among the level of education of women, susceptibility and seriousness was found (p<.001). The study showed that the training program had profound effects on BC knowledge, screening behaviors and health beliefs of women.

  20. Tethered cord in patients affected by anorectal malformations: a survey from the ARM-Net Consortium.

    PubMed

    Fanjul, María; Samuk, I; Bagolan, P; Leva, E; Sloots, C; Giné, C; Aminoff, D; Midrio, P

    2017-08-01

    The goal of this study was to determine the degree of consensus in the management of spinal cord tethering (TC) in patients with anorectal malformation (ARM) in a large cohort of European pediatric centers. A survey was sent to pediatric surgeons (one per center) members of the ARM-Net Consortium. Twenty-four (86%) from ten different countries completed the survey. Overall prevalence of TC was: 21% unknown, 46% below 15, and 29% between 15 and 30%. Ninety-six agreed on screening all patients for TC regardless the type of ARM and 79% start screening at birth. Responses varied in TC definition and diagnostic tools. Fifty percent of respondents prefer ultrasound (US), 21% indicate either US or magnetic resonance (MRI) based on a pre-defined risk of presenting TC, and 21% perform both. Discrepancy exists in complementary test: 82% carry out urodynamic studies (UDS) and only 37% perform somatosensory-evoked potentials (SSEP). Prophylactic untethering is performed in only two centers (8%). Survey results support TC screening in all patients with ARM and conservative management of TC. There is discrepancy in the definition of TC, screening tools, and complementary test. Protocols should be developed to avoid such variability in management.

  1. Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel

    NASA Technical Reports Server (NTRS)

    McQuillen, John B.; Chao, David F.; Hall, Nancy R.; Zhang, Nengli

    2012-01-01

    A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.

  2. Screening for cognitive dysfunction in Huntington's disease with the clock drawing test.

    PubMed

    Terwindt, Paul W; Hubers, Anna A M; Giltay, Erik J; van der Mast, Rose C; van Duijn, Erik

    2016-09-01

    The aim of the study is to investigate the performance of the clock drawing test as a screening tool for cognitive impairment in Huntington's disease (HD) mutation carriers. The performance of the clock drawing test was assessed in 65 mutation carriers using the Shulman and the Freund scoring systems. The mini-mental state examination, the Symbol Digit Modalities Test, the Verbal Fluency Test, and the Stroop tests were used as comparisons for the evaluation of cognitive functioning. Correlations of the clock drawing test with various cognitive tests (convergent validity), neuropsychiatric characteristics (divergent validity) and clinical characteristics were analysed using the Spearman's rank correlation coefficient. Receiver-operator characteristic analyses were performed for the clock drawing test against both the mini-mental state examination and against a composite variable for executive cognitive functioning to assess optimal cut-off scores. Inter-rater reliability was high for both the Shulman and Freund scoring systems (ICC = 0.95 and ICC = 0.90 respectively). The clock drawing tests showed moderate to high correlations with the composite variable for executive cognitive functioning (mean ρ = 0.75) and weaker correlations with the mini-mental state examination (mean ρ = 0.62). Mean sensitivity of the clock drawing tests was 0.82 and mean specificity was 0.79, whereas the mean positive predictive value was 0.66 and the mean negative predictive value was 0.87. The clock drawing test is a suitable screening instrument for cognitive dysfunction in HD, because it was shown to be accurate, particularly so with respect to executive cognitive functioning, and is easy and quick to use. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. [Systematic screening of deafness at a maternity ward using evoked otoacoustic emissions: practical aspects and parental attitudes].

    PubMed

    Moulin, A; Ferber-Viart, C; Berland, M; Dubreuil, C; Duclaux, R

    2001-09-01

    Evaluation of the feasibility and parental attitudes towards a hearing screening programme using evoked otoacoustic emissions, implemented in a maternity ward in France. A hearing screening test using transiently evoked otoacoustic emissions (TEOAE) was proposed to each baby, and an anonymous questionnaire was given to parents to assess their attitudes towards the screening procedure. Although the refusal of the test reached 16% (mainly during the first two weeks of the program), more than 92% of parents judged the test as being useful, and 65% wished it to be systematically done. However, nearly 35% of parents admitted to have a low level anxiety about being unnecessarily worried by the test results. One hundred and twenty-four babies were screened. Fifty three per cent of the tests have been performed in less than ten minutes, with an average of 12.2 minutes. This duration does not include delays due to programme and babies management. False positive rate (uni or bilateral fail) was 10.5% at the first stage. Repeating the test before discharge decreased the false positive rate to 6.5%. Although limited in time, this study shows that a systematic hearing screening programme using TEOAE is possible and should be done in France. False positive rate was below 7%, and the test was considered as useful by more than 90% of parents, although knowledge about deafness in childhood and its consequences were clearly insufficient.

  4. Noninvasive prenatal testing in routine clinical practice--an audit of NIPT and combined first-trimester screening in an unselected Australian population.

    PubMed

    McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus

    2016-02-01

    There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  5. Willingness to Pay for a Newborn Screening Test for Spinal Muscular Atrophy.

    PubMed

    Lin, Pei-Jung; Yeh, Wei-Shi; Neumann, Peter J

    2017-01-01

    The current US mandatory newborn screening panel does not include spinal muscular atrophy, the most common fatal genetic disease among children. We assessed population preferences for newborn screening for spinal muscular atrophy, and how test preferences varied depending on immediate treatment implications. We conducted an online willingness-to-pay survey of US adults (n = 982). Respondents were asked to imagine being parents of a newborn. Each respondent was presented with two hypothetical scenarios following the spinal muscular atrophy screening test: current standard of care (no treatment available) and one of three randomly assigned scenarios (new treatment available to improve functioning, survival, or both). We used a bidding game to elicit willingness to pay for the spinal muscular atrophy test, and performed a two-part model to estimate median and mean willingness-to-pay values. Most respondents (79% to 87%) would prefer screening their newborns for spinal muscular atrophy. People expressed a willingness to pay for spinal muscular atrophy screening even without an available therapy (median: $142; mean: $253). Willingness to pay increased with treatment availability (median: $161 to $182; mean: $270 to $297) and respondent income. Most respondents considered test accuracy, treatment availability, and treatment effectiveness very important or important factors in deciding willingness to pay. Most people would prefer and would be willing to pay for testing their newborn for spinal muscular atrophy, even in the absence of direct treatment. People perceive the spinal muscular atrophy test more valuable if treatment were available to improve the newborn's functioning and survival. Despite preferences for the test information, adding spinal muscular atrophy to newborn screening programs remains controversial. Future studies are needed to determine how early detection may impact long-term patient outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Uptake, outcomes, and costs of implementing non-invasive prenatal testing for Down’s syndrome into NHS maternity care: prospective cohort study in eight diverse maternity units

    PubMed Central

    Wright, David; Hill, Melissa; Verhoef, Talitha I; Daley, Rebecca; Lewis, Celine; Mason, Sarah; McKay, Fiona; Jenkins, Lucy; Howarth, Abigail; Cameron, Louise; McEwan, Alec; Fisher, Jane; Kroese, Mark; Morris, Stephen

    2016-01-01

    Objective To investigate the benefits and costs of implementing non-invasive prenatal testing (NIPT) for Down’s syndrome into the NHS maternity care pathway. Design Prospective cohort study. Setting Eight maternity units across the United Kingdom between 1 November 2013 and 28 February 2015. Participants All pregnant women with a current Down’s syndrome risk on screening of at least 1/1000. Main outcome measures Outcomes were uptake of NIPT, number of cases of Down’s syndrome detected, invasive tests performed, and miscarriages avoided. Pregnancy outcomes and costs associated with implementation of NIPT, compared with current screening, were determined using study data on NIPT uptake and invasive testing in combination with national datasets. Results NIPT was prospectively offered to 3175 pregnant women. In 934 women with a Down’s syndrome risk greater than 1/150, 695 (74.4%) chose NIPT, 166 (17.8%) chose invasive testing, and 73 (7.8%) declined further testing. Of 2241 women with risks between 1/151 and 1/1000, 1799 (80.3%) chose NIPT. Of 71 pregnancies with a confirmed diagnosis of Down’s syndrome, 13/42 (31%) with the diagnosis after NIPT and 2/29 (7%) after direct invasive testing continued, resulting in 12 live births. In an annual screening population of 698 500, offering NIPT as a contingent test to women with a Down’s syndrome screening risk of at least 1/150 would increase detection by 195 (95% uncertainty interval −34 to 480) cases with 3368 (2279 to 4027) fewer invasive tests and 17 (7 to 30) fewer procedure related miscarriages, for a non-significant difference in total costs (£−46 000, £−1 802 000 to £2 661 000). The marginal cost of NIPT testing strategies versus current screening is very sensitive to NIPT costs; at a screening threshold of 1/150, NIPT would be cheaper than current screening if it cost less than £256. Lowering the risk threshold increases the number of Down’s syndrome cases detected and overall costs, while maintaining the reduction in invasive tests and procedure related miscarriages. Conclusions Implementation of NIPT as a contingent test within a public sector Down’s syndrome screening programme can improve quality of care, choices for women, and overall performance within the current budget. As some women use NIPT for information only, the Down’s syndrome live birth rate may not change significantly. Future research should consider NIPT uptake and informed decision making outside of a research setting. PMID:27378786

  7. Uptake, outcomes, and costs of implementing non-invasive prenatal testing for Down's syndrome into NHS maternity care: prospective cohort study in eight diverse maternity units.

    PubMed

    Chitty, Lyn S; Wright, David; Hill, Melissa; Verhoef, Talitha I; Daley, Rebecca; Lewis, Celine; Mason, Sarah; McKay, Fiona; Jenkins, Lucy; Howarth, Abigail; Cameron, Louise; McEwan, Alec; Fisher, Jane; Kroese, Mark; Morris, Stephen

    2016-07-04

     To investigate the benefits and costs of implementing non-invasive prenatal testing (NIPT) for Down's syndrome into the NHS maternity care pathway.  Prospective cohort study.  Eight maternity units across the United Kingdom between 1 November 2013 and 28 February 2015.  All pregnant women with a current Down's syndrome risk on screening of at least 1/1000.  Outcomes were uptake of NIPT, number of cases of Down's syndrome detected, invasive tests performed, and miscarriages avoided. Pregnancy outcomes and costs associated with implementation of NIPT, compared with current screening, were determined using study data on NIPT uptake and invasive testing in combination with national datasets.  NIPT was prospectively offered to 3175 pregnant women. In 934 women with a Down's syndrome risk greater than 1/150, 695 (74.4%) chose NIPT, 166 (17.8%) chose invasive testing, and 73 (7.8%) declined further testing. Of 2241 women with risks between 1/151 and 1/1000, 1799 (80.3%) chose NIPT. Of 71 pregnancies with a confirmed diagnosis of Down's syndrome, 13/42 (31%) with the diagnosis after NIPT and 2/29 (7%) after direct invasive testing continued, resulting in 12 live births. In an annual screening population of 698 500, offering NIPT as a contingent test to women with a Down's syndrome screening risk of at least 1/150 would increase detection by 195 (95% uncertainty interval -34 to 480) cases with 3368 (2279 to 4027) fewer invasive tests and 17 (7 to 30) fewer procedure related miscarriages, for a non-significant difference in total costs (£-46 000, £-1 802 000 to £2 661 000). The marginal cost of NIPT testing strategies versus current screening is very sensitive to NIPT costs; at a screening threshold of 1/150, NIPT would be cheaper than current screening if it cost less than £256. Lowering the risk threshold increases the number of Down's syndrome cases detected and overall costs, while maintaining the reduction in invasive tests and procedure related miscarriages.  Implementation of NIPT as a contingent test within a public sector Down's syndrome screening programme can improve quality of care, choices for women, and overall performance within the current budget. As some women use NIPT for information only, the Down's syndrome live birth rate may not change significantly. Future research should consider NIPT uptake and informed decision making outside of a research setting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Use of GDNF-Releasing Nanofiber Nerve Guide Conduits for the Repair of Conus Medullaris/Cauda Equina Injury in the Non-Human Primate

    DTIC Science & Technology

    2013-10-01

    functional assessments using locomotor testing, urodynamic recordings, electromyography of the pelvic floor , and pain behavioral testing. At 18...selection, trained staff to perform the behavioral screening and evaluation, as well as successfully implementing our procedures for animal enrollment and...to the start of surgical procedures, each enrolled rhesus macaque underwent extensive screening and training . Behavioral records and profiles were

  9. Screening for chlamydial infection.

    PubMed

    Nelson, H D; Helfand, M

    2001-04-01

    To examine data on the effectiveness of screening for chlamydial infection by a physician or other health care professional. Specifically, we examine the evidence that early treatment of chlamydial infection improves health outcomes, as well as evidence of the effectiveness of screening strategies in nonpregnant women, pregnant women, and men, and the accuracy of tests used for screening. This review updates the literature since the last recommendation of the U.S. Preventive Services Task Force published in 1996. We searched the topic of chlamydia in the MEDLINE, HealthSTAR, and Cochrane Library databases from January 1994 to July 2000, supplemented by reference lists of relevant articles and from experts in the field. Articles published prior to 1994 and research abstracts were cited if particularly important to the key questions or to the interpretation of included articles. A single reader reviewed all English abstracts. Articles were selected for full review if they were about Chlamydia trachomatis genitourinary infections in nonpregnant women, pregnant women, or men and were relevant to key questions in the analytic framework. Investigators read the full-text version of the retrieved articles and applied additional eligibility criteria. For all topics, we excluded articles if they did not provide sufficient information to determine the methods for selecting subjects and for analyzing data. We systematically reviewed three types of studies about screening in nonpregnant women that relate to three key questions: (1) studies about the effectiveness of screening programs in reducing prevalence rates of infection, (2) studies about risk factors for chlamydial infection in women, and (3) studies about chlamydial screening tests in women. Our search found too few studies on pregnant women to systematically review, although pertinent studies are described. We systematically reviewed two types of studies about screening in men: (1) studies about prevalence rates and risk factors for chlamydial infection in men and (2) studies about chlamydial screening tests in men. Nonpregnant women. The results of a randomized controlled trial conducted in a large health maintenance organization indicate that screening women selected by a set of risk factors reduces the incidence of pelvic inflammatory disease (PID) over a 1-year period. Changes in population prevalence rates have not been well documented because few studies have employed a representative population sample. Age continues to be the best predictor of chlamydial infection in women, with most studies evaluating cut-offs at age younger than 25 years. Other risk factors may be useful predictors, but these are likely to be population specific. To determine the accuracy of screening tests for women, we retrieved and critically reviewed 34 articles on test performance. Results indicate that endocervical swab specimens and first-void urine specimens have similar performance when using DNA amplification tests and have better sensitivity than endocervical culture. Recurrent chlamydial infections in women have been associated with increased risks for PID and ectopic pregnancies. Pregnant women. The Second Task Force recommendations for screening pregnant women were based on two major studies demonstrating improved pregnancy outcomes following treatment of chlamydial infection. We identified no recent studies on this topic in our literature search. Very few studies describe risk factors for chlamydial infection in pregnant women. Nonculture testing techniques appear to perform well in pregnant women, although studies are limited. Men. No studies described the effectiveness of screening or early treatment for men in reducing transmission to women or in preventing acute infections or complications in men. Studies of prevalence rates and risk factors for chlamydial infection in men are limited. Age lower than 25 years is the strongest known risk factor cited so far. Results of urethral swab specimens compared to first-void urine specimens were similar for DNA amplification tests. DNA amplification techniques are more sensitive than culture. Screening women for Chlamydia trachomatis reduces the incidence of PID, and it is associated with reductions in prevalence of infection in uncontrolled studies. No studies were found to determine whether screening asymptomatic men would reduce transmission or prevent acute infections or complications. Age is the strongest risk factor for men and women. A variety of tests can detect chlamydial infection with acceptable sensitivity and specificity, including new DNA amplification tests that use either endocervical swabs in women, urethral swabs in men, or first-void urine specimens from men and women.

  10. A Field Test of Web-Based Screening for Dry Eye Disease to Enhance Awareness of Eye Problems Among General Internet Users: A Latent Strategy to Promote Health

    PubMed Central

    Uchino, Miki; Kawazoe, Takashi; Kamiyashiki, Masaaki; Sano, Kokoro; Tsubota, Kazuo

    2013-01-01

    Background A Web-based self-check system including a brief questionnaire would seem to be a suitable tool for rapid disease screening. Objective The purpose of this preliminary study was to test a Web-based self-screening questionnaire for drawing attention to dry eye disease among general Internet users and identifying those with a higher risk of developing the condition. Methods A survey website was launched and used to recruit participants from general Internet users. In the first phase, volunteers were asked to complete a Web-based self-screening questionnaire containing 12 questions on dry eye symptoms. The second phase focused on the respondents who reported five or more dry eye symptoms and expressed their intention to seek medical attention. These participants performed the Schirmer test, for evaluating tear production, and completed a paper-based lifestyle questionnaire to provide relevant background data. Results Of the 1689 visitors to the website, 980 (58.0%) volunteers completed the Web-based self-screening questionnaire. Among these, 355 (36.2%) respondents reported five or more dry eye symptoms. Then, 99 (27.9%) of the symptomatic participants performed the Schirmer test and completed the paper-based lifestyle questionnaire. Out of these, 32 (32.2%) had abnormal tear production (≤5 mm). Conclusions The proposed Web-based self-screening questionnaire seems to be a promising tool for raising awareness of dry eye disease among general Internet users and identifying those with a higher risk of developing the condition, although further research is needed to validate its effectiveness. PMID:24072379

  11. Automated Cervical Screening and Triage, Based on HPV Testing and Computer-Interpreted Cytology.

    PubMed

    Yu, Kai; Hyun, Noorie; Fetterman, Barbara; Lorey, Thomas; Raine-Bennett, Tina R; Zhang, Han; Stamps, Robin E; Poitras, Nancy E; Wheeler, William; Befano, Brian; Gage, Julia C; Castle, Philip E; Wentzensen, Nicolas; Schiffman, Mark

    2018-04-11

    State-of-the-art cervical cancer prevention includes human papillomavirus (HPV) vaccination among adolescents and screening/treatment of cervical precancer (CIN3/AIS and, less strictly, CIN2) among adults. HPV testing provides sensitive detection of precancer but, to reduce overtreatment, secondary "triage" is needed to predict women at highest risk. Those with the highest-risk HPV types or abnormal cytology are commonly referred to colposcopy; however, expert cytology services are critically lacking in many regions. To permit completely automatable cervical screening/triage, we designed and validated a novel triage method, a cytologic risk score algorithm based on computer-scanned liquid-based slide features (FocalPoint, BD, Burlington, NC). We compared it with abnormal cytology in predicting precancer among 1839 women testing HPV positive (HC2, Qiagen, Germantown, MD) in 2010 at Kaiser Permanente Northern California (KPNC). Precancer outcomes were ascertained by record linkage. As additional validation, we compared the algorithm prospectively with cytology results among 243 807 women screened at KPNC (2016-2017). All statistical tests were two-sided. Among HPV-positive women, the algorithm matched the triage performance of abnormal cytology. Combined with HPV16/18/45 typing (Onclarity, BD, Sparks, MD), the automatable strategy referred 91.7% of HPV-positive CIN3/AIS cases to immediate colposcopy while deferring 38.4% of all HPV-positive women to one-year retesting (compared with 89.1% and 37.4%, respectively, for typing and cytology triage). In the 2016-2017 validation, the predicted risk scores strongly correlated with cytology (P < .001). High-quality cervical screening and triage performance is achievable using this completely automated approach. Automated technology could permit extension of high-quality cervical screening/triage coverage to currently underserved regions.

  12. Importance of supply integrity for in vitro fertilization and embryo culture.

    PubMed

    Morbeck, Dean E

    2012-06-01

    The quality of in vitro culture conditions is a key component of a successful clinical embryology laboratory. Many, but not all, supplies used in the embryology laboratory are screened by the supplier with a bioassay. Embryology laboratories use a variety of approaches to verify the quality of mineral oil, protein, and disposables before clinical use; however, a best practice has not been determined. Some laboratories test every supply, even those already screened by the supplier, whereas other laboratories perform as little testing as possible. Despite screening by the supplier, recent reports of embryo toxicity, specifically with mineral oil, highlight that the integrity of the supply system has gaps. This review describes current bioassay quality control testing and discusses how it applies to screening of products with documented lot-to-lot variation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Standardized assessment of infrared thermographic fever screening system performance

    NASA Astrophysics Data System (ADS)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  14. Performance of a docking/molecular dynamics protocol for virtual screening of nutlin-class inhibitors of Mdmx.

    PubMed

    Bharatham, Nagakumar; Finch, Kristin E; Min, Jaeki; Mayasundari, Anand; Dyer, Michael A; Guy, R Kiplin; Bashford, Donald

    2017-06-01

    A virtual screening protocol involving docking and molecular dynamics has been tested against the results of fluorescence polarization assays testing the potency of a series of compounds of the nutlin class for inhibition of the interaction between p53 and Mdmx, an interaction identified as a driver of certain cancers. The protocol uses a standard docking method (AutoDock) with a cutoff based on the AutoDock score (ADscore), followed by molecular dynamics simulation with a cutoff based on root-mean-square-deviation (RMSD) from the docked pose. An analysis of the experimental and computational results shows modest performance of ADscore alone, but dramatically improved performance when RMSD is also used. Published by Elsevier Inc.

  15. Receipt of Glucose Testing and Performance of Two US Diabetes Screening Guidelines, 2007–2012

    PubMed Central

    Bullard, Kai McKeever; Ali, Mohammed K.; Imperatore, Giuseppina; Geiss, Linda S.; Saydah, Sharon H.; Albu, Jeanine B.; Cowie, Catherine C.; Sohler, Nancy; Albright, Ann; Gregg, Edward W.

    2015-01-01

    Background Screening guidelines are used to help identify prediabetes and diabetes before implementing evidence-based prevention and treatment interventions. We examined screening practices benchmarking against two US guidelines, and the capacity of each guideline to identify dysglycemia. Methods Using 2007–2012 National Health and Nutrition Examination Surveys, we analyzed nationally-representative, cross-sectional data from 5,813 fasting non-pregnant adults aged ≥20 years without self-reported diabetes. We examined proportions of adults eligible for diagnostic glucose testing and those who self-reported receiving testing in the past three years, as recommended by the American Diabetes Association (ADA) and the US Preventive Services Task Force (USPSTF-2008) guidelines. For each screening guideline, we also assessed sensitivity, specificity, and positive (PPV) and negative predictive values in identifying dysglycemia (defined as fasting plasma glucose ≥100 mg/dl or hemoglobin A1c ≥5.7%). Results In 2007–2012, 73.0% and 23.7% of US adults without diagnosed diabetes met ADA and USPSTF-2008 criteria for screening, respectively; and 91.5% had at least one major risk factor for diabetes. Of those ADA- or USPSTF-eligible adults, about 51% reported being tested within the past three years. Eligible individuals not tested were more likely to be lower educated, poorer, uninsured, or have no usual place of care compared to tested eligible adults. Among adults with ≥1 major risk factor, 45.7% reported being tested, and dysglycemia yields (i.e., PPV) ranged from 45.8% (high-risk ethnicity) to 72.6% (self-reported prediabetes). ADA criteria and having any risk factor were more sensitive than the USPSTF-2008 guideline (88.8–97.7% vs. 31.0%) but less specific (13.5–39.7% vs. 82.1%) in recommending glucose testing, resulting in lower PPVs (47.7–54.4% vs. 58.4%). Conclusion Diverging recommendations and variable performance of different guidelines may be impeding national diabetes prevention and treatment efforts. Efforts to align screening recommendations may result in earlier identification of adults at high risk for prediabetes and diabetes. PMID:25928306

  16. Which routine test for kidney function?

    PubMed Central

    Parkin, A; Smith, H C; Brocklebank, J T

    1989-01-01

    Eighty measurements of plasma creatinine concentration, height:creatinine ratio, and plasma beta 2 microglobulin concentration were made on 72 children (age 4 months-18.5 years) with known renal disease. Results were compared with simultaneous measurements of glomerular filtration rate using plasma clearance of 51Cr edetic acid to assess the performance of each test as an initial screening procedure of renal insufficiency. Height:creatinine index less than 2.1 was found to have a higher sensitivity and predictive value of a normal result than the other tests and is therefore the preferred test for a screening procedure. PMID:2510609

  17. 42 CFR 37.95 - Specifications for performing spirometry examinations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... examinations must include the following: (1) Pre-test checklist. A short Spirometry Pre-Test Checklist (Form... spirometry examinations electronically with content as specified in § 37.96(b), pre-test screening checklists... spirometry examinations, pre-test checklists, and standardized respiratory assessment results in electronic...

  18. Laboratory testing for cytomegalovirus among pregnant women in the United States: a retrospective study using administrative claims data

    PubMed Central

    2012-01-01

    Background Routine cytomegalovirus (CMV) screening during pregnancy is not recommended in the United States and the extent to which it is performed is unknown. Using a medical claims database, we computed rates of CMV-specific testing among pregnant women. Methods We used medical claims from the 2009 Truven Health MarketScan® Commercial databases. We computed CMV-specific testing rates using CPT codes. Results We identified 77,773 pregnant women, of whom 1,668 (2%) had a claim for CMV-specific testing. CMV-specific testing was significantly associated with older age, Northeast or urban residence, and a diagnostic code for mononucleosis. We identified 44 women with a diagnostic code for mononucleosis, of whom 14% had CMV-specific testing. Conclusions Few pregnant women had CMV-specific testing, suggesting that screening for CMV infection during pregnancy is not commonly performed. In the absence of national surveillance for CMV infections during pregnancy, healthcare claims are a potential source for monitoring practices of CMV-specific testing. PMID:23198949

  19. Police corruption and psychological testing: a strategy for preemployment screening.

    PubMed

    Arrigo, Bruce A; Claussen, Natalie

    2003-06-01

    The prediction, control, and prevention of police corruption represent pervasive and enduring problems. Researchers have suggested that intervention at the preemployment screening stage may be the best solution. However, investigators have acknowledged that existing assessment practices are flawed. This article proposes a strategy for the preemployment screening of law enforcement personnel. In particular, it examines the utility of the Inwald Personality Inventory and the Revised-NEO Personality Inventory in relation to assessing antisocial behavioral tendencies and conscientious personality traits, respectively, and argues that their combined use, appropriately administered in a testing situation, represents a reliable and valid predictor of good job performance. The article speculatively comments on this strategy for purposes of psychological testing, future research in the field, and law enforcement administration practices.

  20. Testing and referral patterns in the years surrounding the US Preventive Services Task Force recommendation against prostate-specific antigen screening.

    PubMed

    Hutchinson, Ryan; Akhtar, Abdulhadi; Haridas, Justin; Bhat, Deepa; Roehrborn, Claus; Lotan, Yair

    2016-12-15

    Since the US Preventive Services Task Force (USPSTF) recommended against prostate-specific antigen (PSA) screening, there have been conflicting reports regarding the impact on the behavior of providers. This study analyzed real-world data on PSA ordering and referral practices in the years surrounding the recommendation. A whole-institution sample of entered PSA orders and urology referrals was obtained from the electronic medical record. The study was performed at a tertiary referral center with a catchment in the southern United States. PSA examinations were defined as screening when they were ordered by providers with appointments in internal medicine, family medicine, or general internal medicine. Linear and quadratic regression analyses were performed, and joinpoint regression was used to assess for trend inflection points. Between January 2010 and July 2015, there were 275,784 unique ambulatory visits for men. There were 63,722 raw PSA orders, and 54,684 were evaluable. Primary care providers ordered 17,315 PSA tests and 858 urology referrals. The number of PSA tests per ambulatory visit, the number of referrals per ambulatory visit, the age at the time of the urology referral, and the proportion of PSA tests performed outside the recommended age range did not significantly change. The PSA value at the time of referral increased significantly (P = .022). Joinpoint analysis revealed no joinpoints in the analysis of total PSA orders, screening PSA tests, or examinations per 100 visits. In the years surrounding the USPSTF recommendation, PSA behavior did not change significantly. Patients were referred at progressively higher average PSA levels. The implications for prostate cancer outcomes from these trends warrant further research into provider variables associated with actual PSA utilization. Cancer 2016;122:3785-3793. © 2016 American Cancer Society. © 2016 American Cancer Society.

  1. Screening for ovarian cancer in women with varying levels of risk, using annual tests, results in high recall for repeat screening tests

    PubMed Central

    2011-01-01

    Background We assessed ovarian cancer screening outcomes in women with a positive family history of ovarian cancer divided into a low-, moderate- or high-risk group for development of ovarian cancer. Methods 545 women with a positive family history of ovarian cancer referred to the Ovarian Screening Service at the Royal Marsden Hospital, London from January 2000- December 2008 were included. They were stratified into three risk-groups according to family history (high-, moderate- and low-risk) of developing ovarian cancer and offered annual serum CA 125 and transvaginal ultrasound screening. The high-risk group was offered genetic testing. Results The median age at entry was 44 years. The number of women in the high, moderate and low-risk groups was 397, 112, and 36, respectively. During 2266 women years of follow-up two ovarian cancer cases were found: one advanced stage at her fourth annual screening, and one early stage at prophylactic bilateral salpingo-oophorectomy (BSO). Prophylactic BSO was performed in 138 women (25.3%). Forty-three women had an abnormal CA125, resulting in 59 repeat tests. The re-call rate in the high, moderate and low-risk group was 14%, 3% and 6%. Equivocal transvaginal ultrasound results required 108 recalls in 71 women. The re-call rate in the high, moderate, and low-risk group was 25%, 6% and 17%. Conclusion No early stage ovarian cancer was picked up at annual screening and a significant number of re-calls for repeat screening tests was identified. PMID:22112691

  2. Use of interferon-gamma release assays in a health care worker screening program: experience from a tertiary care centre in the United States.

    PubMed

    Joshi, Manish; Monson, Thomas P; Woods, Gail L

    2012-01-01

    Interferon-gamma release assays including the QuantiFERON-TB Gold In-Tube test (QFT-GIT [Cellestis Ltd, Australia]) may be used in place of the tuberculin skin test (TST) in surveillance programs for Mycobacterium tuberculosis infection control. However, data on performance and practicality of the QFT-GIT in such programs for health care workers (HCWs) are limited. To assess the performance, practicality and reversion rate of the QFT-GIT among HCWs at a tertiary health care institution in the United States. Retrospective chart review of HCWs at Central Arkansas Veterans Healthcare System (Arkansas, USA) who underwent QFT-GIT testing as a part of their employee screening between November 1, 2008 and October 31, 2009. QFT-GIT was used to screen 3290 HCWs. The initial QFT-GIT was interpreted as positive for 129 (3.9%) HCWs, negative for 3155 (95.9%) and indeterminate for six (0.2%). Testing with QFT-GIT was repeated in 45 HCWs who had positive results on the initial test. The QFT-GIT reverted to negative in 18 (40.0%) HCWs, all of whom had negative TST status and initial interferon-gamma values of 0.35 IU⁄mL to 2.0 IU⁄mL. The QFT-GIT test is feasible in large health care setting as an alternative to TST for M tuberculosis infection screening in HCWs but is not free from challenges. The major concerns are the high number of positive test results and high reversion rates on repeat testing, illustrating poor short-term reproducibility of positive QFT-GIT test results. These results suggest adopting a borderline zone between interferon-gamma values of 0.35 IU⁄mL to 2.0 IU⁄mL, and cautious clinical interpretation of values in this range.

  3. Neurocognitive screening of lead-exposed andean adolescents and young adults.

    PubMed

    Counter, S Allen; Buchanan, Leo H; Ortega, Fernando

    2009-01-01

    This study was designed to assess the utility of two psychometric tests with putative minimal cultural bias for use in field screening of lead (Pb)-exposed Ecuadorian Andean workers. Specifically, the study evaluated the effectiveness in Pb-exposed adolescents and young adults of a nonverbal reasoning test standardized for younger children, and compared the findings with performance on a test of auditory memory. The Raven Coloured Progressive Matrices (RCPM) was used as a test of nonverbal intelligence, and the Digit Span subtest of the Wechsler IV intelligence scale was used to assess auditory memory/attention. The participants were 35 chronically Pb-exposed Pb-glazing workers, aged 12-21 yr. Blood lead (PbB) levels for the study group ranged from 3 to 86 microg/dl, with 65.7% of the group at and above 10 microg/dl. Zinc protoporphyrin heme ratios (ZPP/heme) ranged from 38 to 380 micromol/mol, with 57.1% of the participants showing abnormal ZPP/heme (>69 micromol/mol). ZPP/heme was significantly correlated with PbB levels, suggesting chronic Pb exposure. Performance on the RCPM was less than average on the U.S., British, and Puerto Rican norms, but average on the Peruvian norms. Significant inverse associations between PbB/ZPP concentrations and RCPM standard scores using the U.S., Puerto Rican, and Peruvian norms were observed, indicating decreasing RCPM test performance with increasing PbB and ZPP levels. RCPM scores were significantly correlated with performance on the Digit Span test for auditory memory. Mean Digit Span scale score was less than average, suggesting auditory memory/attention deficits. In conclusion, both the RCPM and Digit Span tests were found to be effective instruments for field screening of visual-spatial reasoning and auditory memory abilities, respectively, in Pb-exposed Andean adolescents and young adults.

  4. CT colonography: accuracy, acceptance, safety and position in organised population screening.

    PubMed

    de Haan, Margriet C; Pickhardt, Perry J; Stoker, Jaap

    2015-02-01

    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. The introduction of CRC screening programmes using stool tests and flexible sigmoidoscopy, have been shown to reduce CRC-related mortality substantially. In several European countries, population-based CRC screening programmes are ongoing or being rolled out. Stool tests like faecal occult blood testing are non-invasive and simple to perform, but are primarily designed to detect early invasive cancer. More invasive tests like colonoscopy and CT colonography (CTC) aim at accurately detecting both CRC and cancer precursors, thus providing for cancer prevention. This review focuses on the accuracy, acceptance and safety of CTC as a CRC screening technique and on the current position of CTC in organised population screening. Based on the detection characteristics and acceptability of CTC screening, it might be a viable screening test. The potential disadvantage of radiation exposure is probably overemphasised, especially with newer technology. At this time-point, it is not entirely clear whether the detection of extracolonic findings at CTC is of net benefit and is cost effective, but with responsible handling, this may be the case. Future efforts will seek to further improve the technique, refine appropriate diagnostic algorithms and study cost-effectiveness. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. The evolving role of new imaging methods in breast screening.

    PubMed

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Cognitive determinants of cervical cancer screening behavior among housewife women in Iran: An application of Health Belief Model.

    PubMed

    Babazadeh, Towhid; Nadrian, Haidar; Rezakhani Moghaddam, Hamed; Ezzati, Elaheh; Sarkhosh, Reza; Aghemiri, Shahin

    2018-05-01

    Our aim in this cross-sectional study was to assess the cognitive determinants of Cervical Cancer Screening Behavior (CCSB) among housewife women in Islamabad County, Iran. Through multistage random sampling we recruited and interviewed 280 housewife women. The women who perceived more benefits of performing the Pap test (OR = 1.11), and perceived fewer barriers (OR = 0.915), and higher self-efficacy to perform the test (OR = 1.12) were more likely to have a CCSB in the previous three years. Our findings are informative for the development of targeted interventions to foster CCSB among housewife women.

  7. Participation in colorectal cancer screening trials after first-time invitation: a systematic review.

    PubMed

    Khalid-de Bakker, C; Jonkers, D; Smits, K; Mesters, I; Masclee, A; Stockbrügger, R

    2011-12-01

    Colorectal cancer (CRC) screening is implemented by an increasing number of countries. Participation rates of screening programs influence the health benefit and cost-effectiveness of the applied method. The aim was to systematically review participation rate after first-time invitation for CRC screening with fecal occult blood test (FOBT), sigmoidoscopy, colonoscopy, and/or computed tomography (CT) colonography. A systematic literature search was performed prior to October 1 2009. Prospective CRC screening studies of unselected populations reporting participation rates were included. After meta-analyses, overall participation rates were found to be 47 % for FOBT, 42 % for fecal immunologic tests (FITs), 35 % for sigmoidoscopy, 41 % for sigmoidoscopy combined with FIT/FOBT, 28 % for colonoscopy, and 22 % for CT colonography. Studies comparing screening methods showed higher participation rates for less invasive methods. Studies comparing invitation methods showed higher participation rates with general practitioner involvement, a more personalized recruitment approach, and reduction of barriers that discourage participation. Knowledge of identified factors affecting CRC screening participation can be used to improve screening programs. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Cervical cancer screening: A never-ending developing program

    PubMed Central

    Comparetto, Ciro; Borruto, Franco

    2015-01-01

    With the term “oncological screening”, we define the overall performances made to detect early onset of tumors. These tests are conducted on a population that does not have any signs or symptoms related to a neoplasm. The whole population above a certain age, only one sex, only subjects with a high risk of developing cancer due to genetic, professional, discretionary reasons may be involved. Screening campaigns should be associated, when risk factors that can be avoided are known, with campaigns for the prevention of cancer by means of suitable behavior. The goal of cancer screening cannot however be limited to the diagnosis of a greater number of neoplasms. Screening will be useful only if it leads to a reduction in overall mortality or at least in mortality related to the tumor. Screening should then allow the diagnosis of the disease at a stage when there is a possibility of healing, possibility that is instead difficult when the disease is diagnosed at the appearance of signs or symptoms. This is the reason why not all campaigns of cancer screening have the same effectiveness. In Italy, every year there are about 150000 deaths due to cancer. Some of these tumors can be cured with a very high percentage of success if diagnosed in time. Cervical cancer can be diagnosed with non-invasive tests. The screening test used all over the world is Papanicolaou (Pap) test. This test may be carried out over the entire healthy population potentially exposed to the risk of contracting cancer. Public health has begun the screening campaigns in the hope of saving many of the approximately 270000 new cases of cancer reported each year. Screening is done following protocols that guarantee quality at the national level: these protocols are subject to change over time to reflect new realities or to correct any errors in the system. A simplified sketch of a possible route of cancer screening is as follows: (1) after selecting the target population, for example all women between 25 and 64 years (in the case of monitoring of cervical cancer), an invitation letter with the date and time of the appointment, planned according to the acceptance capacity of the hospital, is sent to all individuals; (2) an examination, which depending on the individual and the type of cancer to be monitored, for example, can be a Pap smear, is performed and the patient can go home; (3) once available the results of examinations, if negative, they shall be communicated to the person concerned that will be notified by mail and will be recalled for a second test at a few years of distance, in the case of non-negativity, instead, the patient is contacted by telephone and informed of the need to carry out further examinations: it is said that the patient is in the “phase two” of the screening pathway; (4) in phase two, reached by only a small portion of the interested parties (usually less than 3%-5%), more in-depth tests are carried out, which, depending on the individual and the type of cancer, can be: cytological and colposcopic examinations, the removal of a fragment of tissue (biopsy) and subsequent histological examination, additional tests such as ultrasound, radiography, or others such as computerized tomography, magnetic resonance imaging, positron emission tomography, etc., in case of negativity, the concerned person will be called for new control tests at a a few years of distance, in case of non-negativity, it will be proposed instead an oncologic therapeutic plan and/or surgery to treat the diagnosed tumor; and (5) once the treatment plan is completed, the individual enters the follow-up protocol, which is monitored over time to see if the tumor has been completely removed or if instead it is still developing. Cervical cancer is undoubtedly the most successful example of a cancer screening campaign. Paradoxically, its effectiveness is one of the strongest reasons to criticize the usefulness of vaccination against human papillomavirus (HPV) in countries where the screening service with Pap test is organized in an efficient manner. Cervical cancer screening protocols are directed to sexually active women aged 25-64 years: they provide the Pap test performed by examining under a microscope or by staining with a specific “thin prep” the material taken from the cervix with a small spatula and a brush. It is recommended to repeat the test every two or three years. It is important to emphasize that women vaccinated against HPV must continue the screening with Pap test. Although some screening programs (e.g., Pap smears) have had remarkable success in reducing mortality from a specific cancer, any kind of screening is free from inherent limitations. The screening methods are in fact applied to large parts of the apparently healthy population. In particular, the limits for certain cancers may be as obvious as to prohibit the introduction of an organized screening program. Potential limitations of organized screenings are basically of two types: organizational and medical. The limits of organizational type relate to the ability of a program to recruit the whole target population. Although well organized, a screening program will hardly be able to exceed a coverage of 70%-80% of the target population, and in fact the results of the current programs are often much smaller. The limits of medical type are represented by the possibility of reducing the overall mortality, or specific mortality, using a specific screening campaign. PMID:26244153

  9. Laboratory audit as part of the quality assessment of a primary HPV-screening program.

    PubMed

    Hortlund, Maria; Sundström, Karin; Lamin, Helena; Hjerpe, Anders; Dillner, Joakim

    2016-02-01

    As primary HPV screening programs are rolled out, methods are needed for routine quality assurance of HPV laboratory analyzes. To explore the use of similar design for audit as currently used in cytology-based screening, to estimate the clinical sensitivity to identify women at risk for CIN 3 or worse (CIN3+). Population-based cohort study conducted within the cervical screening program in Stockholm, Sweden, in 2011-2012. All women with histopathologically confirmed CIN3+ in the following two years were identified by registry analysis. Primary HPV and cytology screening results were collected. For women who had not been HPV tested, biobanked cytology samples were HPV-tested. If the original HPV result had been negative, the sample and subsequent biopsies were analyzed with broad HPV typing (general primer PCR and Luminex). 154 women had a biobanked prediagnostic cytology sample taken up to 2 years before a histopathologically confirmed CIN3+. The high-risk HPV-positivity was 97% (148/154 women), whereas 143/154 (94%) women had had a cytological abnormality. Among the six HPV-negative samples, one sample was HPV 33 positive in repeat testing whereas the other five cases were HPV-negative also on repeat testing, but HPV-positive in the subsequent tumor tissue. A sensitivity of the HPV test that is higher than the sensitivity of cytology suggests adequate quality of the testing. Regular audits of clinical sensitivity, similar to those of cytology-based screening, should be used also in HPV-based screening programs, in order to continuously monitor the performance of the analyzes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Patient navigation improves cancer diagnostic resolution: an individually randomized clinical trial in an underserved population.

    PubMed

    Raich, Peter C; Whitley, Elizabeth M; Thorland, William; Valverde, Patricia; Fairclough, Diane

    2012-10-01

    Barriers to timely resolution of abnormal cancer screening tests add to cancer health disparities among low-income, uninsured, and minority populations. We conducted a randomized trial to evaluate the impact of lay patient navigators on time to resolution and completion of follow-up testing among patients with abnormal screening tests in a medically underserved patient population. Denver Health, the safety-net health care system serving Denver, is one of 10 performance sites participating in the Patient Navigation Research Program. Of 993 eligible subjects with abnormal screening tests randomized to navigation and no-navigation (control) arms and analyzed, 628 had abnormal breast screens (66 abnormal clinical breast examinations, 304 BIRADS 0, 200 BIRADS 3, 58 BIRADS 4 or 5) whereas 235 had abnormal colorectal and 130 had abnormal prostate screens. Time to resolution was significantly shorter in the navigated group (stratified log rank test, P < 0.001). Patient navigation improved diagnostic resolution for patients presenting with mammographic BIRADS 3 (P = 0.0003) and BIRADS 0 (P = 0.09), but not BIRADS 4/5 or abnormal breast examinations. Navigation shortened the time for both colorectal (P = 0.0017) and prostate screening resolution (P = 0.06). Participant demographics included 72% minority, 49% with annual household income less than $10,000, and 36% uninsured. Patient navigation positively impacts time to resolution of abnormal screening tests for breast, colorectal, and prostate cancers in a medically underserved population. By shortening the time to and increasing the proportion of patients with diagnostic resolution patient navigation could reduce disparities in stage at diagnosis and improve cancer outcomes. 2012 AACR

  11. Importance of Urinary Drug Screening in the Multiple Sleep Latency Test and Maintenance of Wakefulness Test.

    PubMed

    Anniss, Angela M; Young, Alan; O'Driscoll, Denise M

    2016-12-15

    Multiple sleep latency testing (MSLT) and the maintenance of wakefulness test (MWT) are gold-standard objective tests of daytime sleepiness and alertness; however, there is marked variability in their interpretation and practice. This study aimed to determine the incidence of positive drug screens and their influence on MSLT, MWT, and polysomnographic variables. All patients attending Eastern Health Sleep Laboratory for MSLT or MWT over a 21-mo period were included in the study. Urinary drug screening for amphetamines, barbiturates, benzodiazepines, cannabinoids, cocaine, methadone, and opiates was performed following overnight polysomnography (PSG). Demographics and PSG variables were compared. Of 69 studies, MSLT (43) and MWT (26), 16% of patients had positive urinary drug screening (7 MSLT; 4 MWT). Drugs detected included amphetamines, cannabinoids, opiates, and benzodiazepines. No patient self-reported use of these medications prior to testing. No demographic, MSLT or MWT PSG data or overnight PSG data showed any statistical differences between positive and negative drug screen groups. Of seven MSLT patients testing positive for drug use, one met criteria for the diagnosis of narcolepsy and five for idiopathic hypersomnia. On MWT, three of the four drug-positive patients had a history of a motor vehicle accident and two patients were occupational drivers. These findings indicate drug use is present in patients attending for daytime testing of objective sleepiness and wakefulness. These data support routine urinary drug screening in all patients undergoing MSLT or MWT studies to ensure accurate interpretation in the context of illicit and prescription drug use. © 2016 American Academy of Sleep Medicine

  12. Cost-effectiveness of HPV-based cervical cancer screening in the public health system in Nicaragua.

    PubMed

    Campos, Nicole G; Mvundura, Mercy; Jeronimo, Jose; Holme, Francesca; Vodicka, Elisabeth; Kim, Jane J

    2017-06-15

    To evaluate the cost-effectiveness of human papillomavirus (HPV) DNA testing (versus Papanicolaou (Pap)-based screening) for cervical cancer screening in Nicaragua. A previously developed Monte Carlo simulation model of the natural history of HPV infection and cervical cancer was calibrated to epidemiological data from Nicaragua. Cost data inputs were derived using a micro-costing approach in Carazo, Chontales and Chinandega departments; test performance data were from a demonstration project in Masaya department. Nicaragua's public health sector facilities. Women aged 30-59 years. Screening strategies included (1) Pap testing every 3 years, with referral to colposcopy for women with an atypical squamous cells of undetermined significance or worse result ('Pap'); (2) HPV testing every 5 years, with referral to cryotherapy for HPV-positive eligible women (HPV cryotherapy or 'HPV-Cryo'); (3) HPV testing every 5 years, with referral to triage with visual inspection with acetic acid (VIA) for HPV-positive women ('HPV-VIA'); and (4) HPV testing every 5 years, with referral to Pap testing for HPV-positive women ('HPV-Pap'). Reduction in lifetime risk of cancer and incremental cost-effectiveness ratios (ICER; 2015 US$ per year of life saved (YLS)). HPV-based screening strategies were more effective than Pap testing. HPV-Cryo was the least costly and most effective strategy, reducing lifetime cancer risk by 29.5% and outperforming HPV-VIA, HPV-Pap and Pap only, which reduced cancer risk by 19.4%, 12.2% and 10.8%, respectively. With an ICER of US$320/YLS, HPV-Cryo every 5 years would be very cost-effective using a threshold based on Nicaragua's per capita gross domestic product of US$2090. Findings were robust across sensitivity analyses on test performance, coverage, compliance and cost parameters. HPV testing is very cost-effective compared with Pap testing in Nicaragua, due to higher test sensitivity and the relatively lower number of visits required. Increasing compliance with recommended follow-up will further improve the health benefits and value for public health dollars. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Cost-effectiveness of HPV-based cervical cancer screening in the public health system in Nicaragua

    PubMed Central

    Mvundura, Mercy; Jeronimo, Jose; Holme, Francesca; Vodicka, Elisabeth; Kim, Jane J

    2017-01-01

    Objectives To evaluate the cost-effectiveness of human papillomavirus (HPV) DNA testing (versus Papanicolaou (Pap)-based screening) for cervical cancer screening in Nicaragua. Design A previously developed Monte Carlo simulation model of the natural history of HPV infection and cervical cancer was calibrated to epidemiological data from Nicaragua. Cost data inputs were derived using a micro-costing approach in Carazo, Chontales and Chinandega departments; test performance data were from a demonstration project in Masaya department. Setting Nicaragua’s public health sector facilities. Participants Women aged 30–59 years. Interventions Screening strategies included (1) Pap testing every 3 years, with referral to colposcopy for women with an atypical squamous cells of undetermined significance or worse result (‘Pap’); (2) HPV testing every 5 years, with referral to cryotherapy for HPV-positive eligible women (HPV cryotherapy or ‘HPV-Cryo’); (3) HPV testing every 5 years, with referral to triage with visual inspection with acetic acid (VIA) for HPV-positive women (‘HPV-VIA’); and (4) HPV testing every 5 years, with referral to Pap testing for HPV-positive women (‘HPV-Pap’). Outcome measures Reduction in lifetime risk of cancer and incremental cost-effectiveness ratios (ICER; 2015 US$ per year of life saved (YLS)). Results HPV-based screening strategies were more effective than Pap testing. HPV-Cryo was the least costly and most effective strategy, reducing lifetime cancer risk by 29.5% and outperforming HPV-VIA, HPV-Pap and Pap only, which reduced cancer risk by 19.4%, 12.2% and 10.8%, respectively. With an ICER of US$320/YLS, HPV-Cryo every 5 years would be very cost-effective using a threshold based on Nicaragua’s per capita gross domestic product of US$2090. Findings were robust across sensitivity analyses on test performance, coverage, compliance and cost parameters. Conclusions HPV testing is very cost-effective compared with Pap testing in Nicaragua, due to higher test sensitivity and the relatively lower number of visits required. Increasing compliance with recommended follow-up will further improve the health benefits and value for public health dollars. PMID:28619772

  14. Why hasn't this patient been screened for colon cancer? An Iowa Research Network study.

    PubMed

    Levy, Barcey T; Nordin, Terri; Sinift, Suzanne; Rosenbaum, Marcy; James, Paul A

    2007-01-01

    Less than half of eligible Americans have been screened for colorectal cancer (CRC). The objective of this study was to describe physicians' reasons for screening or not screening specific patients for CRC and their approach to CRC testing discussions. This study used mixed-methods. Physicians described their reasons for screening or not screening 6 randomly chosen patients who were eligible for CRC screening (3 screened and 3 not screened) whose CRC testing status was ascertained by medical record review. Verbatim transcripts from physicians responding to structured interview questions were used to identify themes. Specific elements of discussion were examined for their association with each physician's screening rate. Fifteen randomly chosen Iowa family physicians from the Iowa Research Network stratified by privileges to perform colonoscopy, flexible sigmoidoscopy, or neither procedure dictated the reasons why 43 patients were screened and 40 patients were not screened. Reasons patients were not up to date fell into 2 major categories: (1) no discussion by physician (50%) and (2) patient refusal (43%). Reasons for no discussion included lack of opportunity, assessment that cost would be prohibitive, distraction by other life issues/health problems, physician forgetfulness, and expected patient refusal. Patients declined because of cost, lack of interest, autonomy, other life issues, fear of screening, and lack of symptoms. Patients who were up to date received (1) diagnostic testing (for previous colon pathology or symptoms; 56%) or (2) asymptomatic screening (44%). Physicians who were more adamant about screening had higher screening rates (P<.05; Wilcoxon rank sum). Physicians framed their recommendations differently ("I recommend" vs "They recommend"), with lower screening rates among physicians who used "they recommend" (P=.05; Wilcoxon rank sum). Reasons many patients remain unscreened for CRC include (1) factors related to the health care system, patient, and physician that impede or prevent discussion; (2) patient refusal; and (3) the focus on diagnostic testing. Strategies to improve screening might include patient and physician education about the rationale for screening, universal coverage for health maintenance exams, and development of effective tracking and reminder systems. The words physicians choose to frame their recommendations are important and should be explored further.

  15. Chorionic villus sampling for abnormal screening compared to historical indications: prevalence of abnormal karyotypes.

    PubMed

    Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo

    2012-08-01

    To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.

  16. Comparing self- and provider-collected swabbing for HPV DNA testing in female-to-male transgender adult patients: a mixed-methods biobehavioral study protocol.

    PubMed

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy; Pardee, Dana J; McLean, Sarah; Marrow, Elliot J; Mimiaga, Matthew J; Panther, Lori; Gelman, Marcy; Green, Jamison; Potter, Jennifer

    2017-06-23

    Cervical cancer, nearly all cases of which are caused by one of several high-risk strains of the human papillomavirus (hr-HPV), leads to significant morbidity and mortality in individuals with a cervix. Trans masculine (TM) individuals were born with female reproductive organs and identify as male, man, transgender man, or another diverse gender identity different from their female assigned sex at birth. Routine preventive sexual health screening of TM patients is recommended, including screening for cervical cancer and other sexually transmitted infections (STIs); however, as many as one in three TM patients are not up-to-date per recommended U.S. Among cisgender (non-transgender) women, self-swab hr.-HPV DNA testing as a primary cervical cancer screening method and self-swab specimen collection for other STIs have high levels of acceptability. No study has yet been conducted to compare the performance and acceptability of self- and provider-collected swabs for hr.-HPV DNA testing and other STIs in TM patients. This article describes the study protocol for a mixed-methods biobehavioral investigation enrolling 150 sexually active TM to (1) assess the clinical performance and acceptability of a vaginal self-swab for hr.-HPV DNA testing compared to provider cervical swab and cervical cytology, and (2) gather acceptability data on self-collected specimens for other STIs. Study participation entails a one-time clinical visit at Fenway Health in Boston, MA comprised of informed consent, quantitative assessment, venipuncture for syphilis testing and HIV (Rapid OraQuick) testing, randomization, collection of biological specimens/biomarkers, participant and provider satisfaction survey, and qualitative exit interview. Participants are compensated $100. The primary study outcomes are concordance (kappa statistic) and performance (sensitivity and specificity) of self-collected vaginal HPV DNA specimens vs provider-collected cervical HPV swabs as a gold standard. This study addresses critical gaps in current clinical knowledge of sexual health in TM patients, including comparing alternative strategies for screening and diagnosis of cervical cancer, hr.-HPV, and other STIs. Findings have implications for improving the delivery of sexual health screening to this often overlooked and underserved patient population. Less-invasive patient-centered strategies may also generalize to other at-risk cisgender female populations that face barriers to timely and needed STI and cervical cancer screening. ClinicalTrials.gov ID: NCT02401867.

  17. Effect of provider and patient reminders, deployment of nurse practitioners, and financial incentives on cervical and breast cancer screening rates.

    PubMed

    Kaczorowski, Janusz; Hearps, Stephen J C; Lohfeld, Lynne; Goeree, Ron; Donald, Faith; Burgess, Ken; Sebaldt, Rolf J

    2013-06-01

    To evaluate the effect of the Provider and Patient Reminders in Ontario: Multi-Strategy Prevention Tools (P-PROMPT) reminder and recall system and pay-for-performance incentives on the delivery rates of cervical and breast cancer screening in primary care practices in Ontario, with or without deployment of nurse practitioners (NPs). Before-and-after comparisons of the time-appropriate delivery rates of cervical and breast cancer screening using the automated and NP-augmented strategies of the P-PROMPT reminder and recall system. Southwestern Ontario. A total of 232 physicians from 24 primary care network or family health network groups across 110 different sites eligible for pay-for-performance incentives. The P-PROMPT project combined pay-for-performance incentives with provider and patient reminders and deployment of NPs to enhance the delivery of preventive care services. The mean delivery rates at the practice level of time-appropriate mammograms and Papanicolaou tests completed within the previous 30 months. Before-and-after comparisons of time-appropriate delivery rates (< 30 months) of cancer screening showed the rates of Pap tests and mammograms for eligible women significantly increased over a 1-year period by 6.3% (P < .001) and 5.3% (P < .001), respectively. The NP-augmented strategy achieved comparable rate increases to the automated strategy alone in the delivery rates of both services. The use of provider and patient reminders and pay-for-performance incentives resulted in increases in the uptake of Pap tests and mammograms among eligible primary care patients over a 1-year period in family practices in Ontario.

  18. Identification and Validation of a Brief Test Anxiety Screening Tool

    ERIC Educational Resources Information Center

    von der Embse, Nathaniel P.; Kilgus, Stephen P.; Segool, Natasha; Putwain, Dave

    2013-01-01

    The implementation of test-based accountability policies around the world has increased the pressure placed on students to perform well on state achievement tests. Educational researchers have begun taking a closer look at the reciprocal effects of test anxiety and high-stakes testing. However, existing test anxiety assessments lack efficiency and…

  19. Experimental Seismic Event-screening Criteria at the Prototype International Data Center

    NASA Astrophysics Data System (ADS)

    Fisk, M. D.; Jepsen, D.; Murphy, J. R.

    - Experimental seismic event-screening capabilities are described, based on the difference of body-and surface-wave magnitudes (denoted as Ms:mb) and event depth. These capabilities have been implemented and tested at the prototype International Data Center (PIDC), based on recommendations by the IDC Technical Experts on Event Screening in June 1998. Screening scores are presented that indicate numerically the degree to which an event meets, or does not meet, the Ms:mb and depth screening criteria. Seismic events are also categorized as onshore, offshore, or mixed, based on their 90% location error ellipses and an onshore/offshore grid with five-minute resolution, although this analysis is not used at this time to screen out events.Results are presented of applications to almost 42,000 events with mb>=3.5 in the PIDC Standard Event Bulletin (SEB) and to 121 underground nuclear explosions (UNE's) at the U.S. Nevada Test Site (NTS), the Semipalatinsk and Novaya Zemlya test sites in the Former Soviet Union, the Lop Nor test site in China, and the Indian, Pakistan, and French Polynesian test sites. The screening criteria appear to be quite conservative. None of the known UNE's are screened out, while about 41 percent of the presumed earthquakes in the SEB with mb>=3.5 are screened out. UNE's at the Lop Nor, Indian, and Pakistan test sites on 8 June 1996, 11 May 1998, and 28 May 1998, respectively, have among the lowest Ms:mb scores of all events in the SEB.To assess the validity of the depth screening results, comparisons are presented of SEB depth solutions to those in other bulletins that are presumed to be reliable and independent. Using over 1600 events, the comparisons indicate that the SEB depth confidence intervals are consistent with or shallower than over 99.8 percent of the corresponding depth estimates in the other bulletins. Concluding remarks are provided regarding the performance of the experimental event-screening criteria, and plans for future improvements, based on recent recommendations by the IDC Technical Experts on Event Screening in May 1999.

  20. Feasibility of nonselective testing for hemoglobinopathies in early pregnancy in The Netherlands.

    PubMed

    Kaufmann, Judith O; Demirel-Güngör, Gönül; Selles, Anke; Hudig, Cisca; Steen, Gerard; Ponjee, Gabrielle; Holleboom, Cas; Freeman, Liv M; Hendiks, Joris; Wijermans, Pierre; Giordano, Piero C; Kerkhoffs, Jean-Louis

    2011-12-01

    To examine the feasibility of standardized hemoglobinopathy (HBP) carrier testing for pregnant women in The Netherlands in addition to the standard anemia screening. We assessed the prevalence of HBP in women at the time of the first pregnancy visit using both a prospective cohort (N = 703) and a retrospective series of women selected at random (N = 588). For the purpose of analysis, the population was divided into a high risk and a low risk group for HBP based on maternal ethnicity. Screening for HBP utilized standard screening tests for anemia, with additional high performance liquid chromatography (Variant II); molecular analysis was performed by Gap-polymerase chain reaction (Gap-PCR) and if necessary, direct sequencing and multiplex ligation-dependent probe amplification (MLPA). Family history was reported or collected from the medical records. β-Globin defects were found in 3.9% of the total population (50/1291). The frequency in the high risk population was 5.6% (37/656), compared with 1.2% (6/501) in the low risk group. In the prospective study we found 30 HBP carriers, leading to testing of 16 partners and identification of two couples at risk. One affected child was born. Mean gestational age at the screening was 11.3 weeks with a standard deviation (SD) of 5.8. We found that the prevalence of HBP carriers is high enough in our population to warrant HBP testing for the entire multiethnic population in early pregnancy at the time of anemia screening. This is feasible as most women had their booking early in their first trimester. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test

    PubMed Central

    Ortiz, Daniel A.

    2017-01-01

    ABSTRACT A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing (n = 231). The results from the RPR-reactive samples (n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. PMID:28878003

  2. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    PubMed

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  3. Field performance of clinical case definitions for influenza screening during the 2009 pandemic.

    PubMed

    Chen, Shey-Ying; Chen, Yee-Chun; Chiang, Wen-Chu; Kung, Hsiang-Chi; King, Chwan-Chuen; Lai, Mei-Shu; Chie, Wei-Chu; Chen, Shyr-Chyr; Chen, Wen-Jone; Chang, Shan-Chwen

    2012-11-01

    The aim of this study was to assess the performance of 3 different influenza-like illness (ILI) case definitions, adopted by the European (European-CDC), USA (USA-CDC), and Taiwan Centers for Disease Prevention and Control (Taiwan-CDC), as screening tools for influenza during the 2009 H1N1 pandemic. From August 15 to 30, 2009, all emergency department patients with clinical symptoms or at epidemiologic risk for influenza were enrolled in an observational cohort study. Influenza diagnosis was established by positive rapid influenza diagnostic test or virus isolation. Sensitivity, specificity, positive predictive value, and negative predictive value of the European-, USA, and Taiwan-CDC ILI case definitions for screening were determined. A total of 870 patients were screened during the study period. Rapid influenza diagnostic test was positive in 315 patients, 273 (85.6%) of whom had fever duration less than 72 hours. Virus isolation identified 4 more patients with influenza A initially negative by rapid influenza diagnostic test. The mean (SD) age of these 319 patients was 24.3 (18.1) years. Of the 870 screened patients, 670 (77.0%), 476 (54.7%), and 325 (37.4%) met the European-, USA-, and Taiwan-CDC ILI case definition, respectively. Screening sensitivity was 95%, 77.7%, and 57.7% and specificity was 33.4%, 58.6%, and 74.4%, respectively. Differences in sensitivity and specificity between any 2 of the 3 groups were statistically significant (P < .05). First-line physicians should recognize the advantage and limitation of different ILI case definitions in influenza screening, especially confronted by pandemic or highly pathogenic avian influenza in the future. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. [The prevalence of yaws among the Aka in the Congo].

    PubMed

    Coldiron, M; Obvala, D; Mouniaman-Nara, I; Pena, J; Blondel, C; Porten, K

    2013-05-01

    This study, conducted in 2012 in two districts of the Congo (Bétou and Enyellé), screened for yaws (endemic treponemiasis) that could be treated by a single dose of azithromycin. The screening involved a clinical history, followed by a clinical examination of the children reporting dermatological problems. A rapid diagnostic test for treponema was performed on the children with suspicious lesions. Of 6215 children screened, 485 (7.8%) had such lesions; 480 (99.0%) of them had a rapid diagnostic test, and it was positive for 183 (38.1%). This so-called Morges strategy is aimed at eradicating yaws in endemic areas.

  5. Screening HIV-Infected Patients with Low CD4 Counts for Cryptococcal Antigenemia prior to Initiation of Antiretroviral Therapy: Cost Effectiveness of Alternative Screening Strategies in South Africa.

    PubMed

    Larson, Bruce A; Rockers, Peter C; Bonawitz, Rachael; Sriruttan, Charlotte; Glencross, Deborah K; Cassim, Naseem; Coetzee, Lindi M; Greene, Gregory S; Chiller, Tom M; Vallabhaneni, Snigdha; Long, Lawrence; van Rensburg, Craig; Govender, Nelesh P

    2016-01-01

    In 2015 South Africa established a national cryptococcal antigenemia (CrAg) screening policy targeted at HIV-infected patients with CD4+ T-lymphocyte (CD4) counts <100 cells/ μl who are not yet on antiretroviral treatment (ART). Two screening strategies are included in national guidelines: reflex screening, where a CrAg test is performed on remnant blood samples from CD4 testing; and provider-initiated screening, where providers order a CrAg test after a patient returns for CD4 test results. The objective of this study was to compare costs and effectiveness of these two screening strategies. We developed a decision analytic model to compare reflex and provider-initiated screening in terms of programmatic and health outcomes (number screened, number identified for preemptive treatment, lives saved, and discounted years of life saved) and screening and treatment costs (2015 USD). We estimated a base case with prevalence and other parameters based on data collected during CrAg screening pilot projects integrated into routine HIV care in Gauteng, Free State, and Western Cape Provinces. We conducted sensitivity analyses to explore how results change with underlying parameter assumptions. In the base case, for each 100,000 CD4 tests, the reflex strategy compared to the provider-initiated strategy has higher screening costs ($37,536 higher) but lower treatment costs ($55,165 lower), so overall costs of screening and treatment are $17,629 less with the reflex strategy. The reflex strategy saves more lives (30 lives, 647 additional years of life saved). Sensitivity analyses suggest that reflex screening dominates provider-initiated screening (lower total costs and more lives saved) or saves additional lives for small additional costs (< $125 per life year) across a wide range of conditions (CrAg prevalence, patient and provider behavior, patient survival without treatment, and effectiveness of preemptive fluconazole treatment). In countries with substantial numbers of people with untreated, advanced HIV disease such as South Africa, CrAg screening before initiation of ART has the potential to reduce cryptococcal meningitis and save lives. Reflex screening compared to provider-initiated screening saves more lives and is likely to be cost saving or have low additional costs per additional year of life saved.

  6. Screening HIV-Infected Patients with Low CD4 Counts for Cryptococcal Antigenemia prior to Initiation of Antiretroviral Therapy: Cost Effectiveness of Alternative Screening Strategies in South Africa

    PubMed Central

    Rockers, Peter C.; Bonawitz, Rachael; Sriruttan, Charlotte; Glencross, Deborah K.; Cassim, Naseem; Coetzee, Lindi M.; Greene, Gregory S.; Chiller, Tom M.; Vallabhaneni, Snigdha; Long, Lawrence; van Rensburg, Craig; Govender, Nelesh P.

    2016-01-01

    Background In 2015 South Africa established a national cryptococcal antigenemia (CrAg) screening policy targeted at HIV-infected patients with CD4+ T-lymphocyte (CD4) counts <100 cells/ μl who are not yet on antiretroviral treatment (ART). Two screening strategies are included in national guidelines: reflex screening, where a CrAg test is performed on remnant blood samples from CD4 testing; and provider-initiated screening, where providers order a CrAg test after a patient returns for CD4 test results. The objective of this study was to compare costs and effectiveness of these two screening strategies. Methods We developed a decision analytic model to compare reflex and provider-initiated screening in terms of programmatic and health outcomes (number screened, number identified for preemptive treatment, lives saved, and discounted years of life saved) and screening and treatment costs (2015 USD). We estimated a base case with prevalence and other parameters based on data collected during CrAg screening pilot projects integrated into routine HIV care in Gauteng, Free State, and Western Cape Provinces. We conducted sensitivity analyses to explore how results change with underlying parameter assumptions. Results In the base case, for each 100,000 CD4 tests, the reflex strategy compared to the provider-initiated strategy has higher screening costs ($37,536 higher) but lower treatment costs ($55,165 lower), so overall costs of screening and treatment are $17,629 less with the reflex strategy. The reflex strategy saves more lives (30 lives, 647 additional years of life saved). Sensitivity analyses suggest that reflex screening dominates provider-initiated screening (lower total costs and more lives saved) or saves additional lives for small additional costs (< $125 per life year) across a wide range of conditions (CrAg prevalence, patient and provider behavior, patient survival without treatment, and effectiveness of preemptive fluconazole treatment). Conclusions In countries with substantial numbers of people with untreated, advanced HIV disease such as South Africa, CrAg screening before initiation of ART has the potential to reduce cryptococcal meningitis and save lives. Reflex screening compared to provider-initiated screening saves more lives and is likely to be cost saving or have low additional costs per additional year of life saved. PMID:27390864

  7. Risk stratification in cervical cancer screening by complete screening history: Applying bioinformatics to a general screening population.

    PubMed

    Baltzer, Nicholas; Sundström, Karin; Nygård, Jan F; Dillner, Joakim; Komorowski, Jan

    2017-07-01

    Women screened for cervical cancer in Sweden are currently treated under a one-size-fits-all programme, which has been successful in reducing the incidence of cervical cancer but does not use all of the participants' available medical information. This study aimed to use women's complete cervical screening histories to identify diagnostic patterns that may indicate an increased risk of developing cervical cancer. A nationwide case-control study was performed where cervical cancer screening data from 125,476 women with a maximum follow-up of 10 years were evaluated for patterns of SNOMED diagnoses. The cancer development risk was estimated for a number of different screening history patterns and expressed as Odds Ratios (OR), with a history of 4 benign cervical tests as reference, using logistic regression. The overall performance of the model was moderate (64% accuracy, 71% area under curve) with 61-62% of the study population showing no specific patterns associated with risk. However, predictions for high-risk groups as defined by screening history patterns were highly discriminatory with ORs ranging from 8 to 36. The model for computing risk performed consistently across different screening history lengths, and several patterns predicted cancer outcomes. The results show the presence of risk-increasing and risk-decreasing factors in the screening history. Thus it is feasible to identify subgroups based on their complete screening histories. Several high-risk subgroups identified might benefit from an increased screening density. Some low-risk subgroups identified could likely have a moderately reduced screening density without additional risk. © 2017 UICC.

  8. Identifying congenital hearing impairment. Personal experience based on selective hearing screening.

    PubMed

    Molini, E; Ricci, G; Baroni, S; Ciorba, A; Bellocci, A; Simoncelli, C

    2004-06-01

    If all degrees of permanent uni- or bilateral hypoacusis are taken into consideration, hearing impairment is the most common congenital disease. Early detection of permanent infantile hearing impairment has become extremely important in preventive medicine, since steps can be taken with hearing aids and rehabilitation to ensure better development of language and higher cognitive functions. Aim of this study is to provide a critical review of the time of diagnosis of hypoacusis at our audiology laboratory, where two methods were used to screen hearing of children with/without risk indicators. Results of approximately 10 years' work were re-examined during which time outpatient screening was conducted on children referred by colleagues in neonatology and paediatrics. All were carriers of congenital risk indicators associated with sensorineural and/or conductive hearing loss, based on the Joint Committee on Infant Hearing findings, or were suspected of being hypoacusic even if they had no known congenital risk factors. Hearing screening was conducted in hospital on newborns with no risk factors, within the first few days of birth. Results of the present study showed that when selective hearing screening was performed, the mean age of high-risk patients diagnosed with hypoacusis was slightly higher than that in international guidelines. Moreover, these patients represent approximately half the hypoacusic population identified in the study period. The other half of congenital hypoacusic subjects identified had no risk indicators and there was a significant delay in diagnosis due to later manifestation of symptoms indicating hypoacusis, and thus, in turn, delayed referral for hearing tests. In contrast, subjects without risk indicators who underwent in-hospital hearing screening and proved to be hypoacusic, were diagnosed early. In our experience, however, universal screening has considerable disadvantages, such as difficulty in covering the entire population, difficulty in follow-up after discharge from hospital, and last, but by no means least, significant organisational and professional commitments, making it impossible to perform in all hospitals. In order to ensure effective hearing screening for congenital hearing loss and, thus permit prompt identification of hypoacusic children, use of hearing aids and rehabilitation screening should incorporate two aspects. First, selection should be compulsory, thereby reducing waiting time between collecting case histories and performing outpatient tests; second, hospital screening of children without risk factors should be performed whenever possible. Integrating these two aspects would make it possible to approach the "utopia" of universal hearing screening.

  9. Hit identification and optimization in virtual screening: practical recommendations based on a critical literature analysis.

    PubMed

    Zhu, Tian; Cao, Shuyi; Su, Pin-Chih; Patel, Ram; Shah, Darshan; Chokshi, Heta B; Szukala, Richard; Johnson, Michael E; Hevener, Kirk E

    2013-09-12

    A critical analysis of virtual screening results published between 2007 and 2011 was performed. The activity of reported hit compounds from over 400 studies was compared to their hit identification criteria. Hit rates and ligand efficiencies were calculated to assist in these analyses, and the results were compared with factors such as the size of the virtual library and the number of compounds tested. A series of promiscuity, druglike, and ADMET filters were applied to the reported hits to assess the quality of compounds reported, and a careful analysis of a subset of the studies that presented hit optimization was performed. These data allowed us to make several practical recommendations with respect to selection of compounds for experimental testing, definition of hit identification criteria, and general virtual screening hit criteria to allow for realistic hit optimization. A key recommendation is the use of size-targeted ligand efficiency values as hit identification criteria.

  10. Screening with HbA1c identifies only one in two individuals with diagnosis of prediabetes at oral glucose tolerance test: findings in a real-world Caucasian population.

    PubMed

    Chilelli, Nino Cristiano; Cosma, Chiara; Ragazzi, Eugenio; Burlina, Silvia; Zaninotto, Martina; Plebani, Mario; Lapolla, Annunziata

    2014-10-01

    Discordance between HbA1c and OGTT in screening pre-diabetes may occur because of lack of laboratory standardization, distinct underlying pathophysiological processes or different ethnicity. We evaluated HbA1c efficacy for screening OGTT-defined IFG and IGT conditions in a large Caucasian population using the newly revised IFCC protocol. A total of 501 consecutive subjects were screened for pre-diabetic conditions with OGTT with 75 g of glucose. Testing for HbA1c, lipid profile and fasting insulin levels was also performed. For detecting differences between continuous variables, ANOVA followed by Tukey's honestly significant difference (HSD) post hoc test was used. Logistic regression and ROC curve analysis were also performed for assessing HbA1c screening efficacy. ROC curve analysis showed that optimal HbA1c cut-off for detecting IFG was 5.6 % (sensitivity of 78 % and specificity of 63 %), while for IGT, the optimal cut-off was 5.9 % (sensitivity of 46 % and specificity of 84 %), with AUCs < 0.8. Screening with HbA1c identified 53.4 % of the 193 patients with IFG and/or IGT diagnosed at OGTT. As regards surrogate markers of insulin resistance, we observed a trend towards higher values of HOMA-IR and lower QUICKI values in subjects with IFG than in those with IGT. Patients with pre-diabetes at both tests had similar values of HOMA and QUICKI, compared with those with altered OGTT only. IFCC-aligned HbA1c assay proved scarcely effective in detecting IFG and/or IGT in a large Caucasian population, identifying only half of the patients with abnormal OGTT. Moreover, adding HbA1c screening to OGTT may be of little benefit in identifying subjects with a worse metabolic profile.

  11. Corrosion testing of candidates for the alkaline fuel cell cathode

    NASA Technical Reports Server (NTRS)

    Singer, Joseph; Fielder, William L.

    1990-01-01

    Current/voltage data have been obtained for specially made corrosion electrodes of some oxides and of gold materials for the purpose of developing a screening test of catalysts and supports for use at the cathode of the alkaline fuel cell. The data consist of measurements of current at fixed potentials and cyclic voltammograms. These data will have to be correlated with longtime performance data in order to evaluate fully this approach to corrosion screening.

  12. Development of a test of suprathreshold acuity in noise in Brazilian Portuguese: a new method for hearing screening and surveillance.

    PubMed

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  13. Brief screening questionnaires to identify problem drinking during pregnancy: a systematic review.

    PubMed

    Burns, Ethel; Gray, Ron; Smith, Lesley A

    2010-04-01

    Although prenatal screening for problem drinking during pregnancy has been recommended, guidance on screening instruments is lacking. We investigated the sensitivity, specificity and predictive value of brief alcohol screening questionnaires to identify problem drinking in pregnant women. Electronic databases from their inception to June 2008 were searched, as well as reference lists of eligible papers and related review papers. We sought cohort or cross-sectional studies that compared one or more brief alcohol screening questionnaire(s) with reference criteria obtained using structured interviews to detect 'at-risk' drinking, alcohol abuse or dependency in pregnant women receiving prenatal care. Five studies (6724 participants) were included. In total, seven instruments were evaluated: TWEAK (Tolerance, Worried, Eye-opener, Amnesia, Kut down), T-ACE [Take (number of drinks), Annoyed, Cut down, Eye-opener], CAGE (Cut down, Annoyed, Guilt, Eye-opener], NET (Normal drinker, Eye-opener, Tolerance), AUDIT (Alcohol Use Disorder Identification Test), AUDIT-C (AUDIT-consumption) and SMAST (Short Michigan Alcohol Screening Test). Study quality was generally good, but lack of blinding was a common weakness. For risk drinking sensitivity was highest for T-ACE (69-88%), TWEAK (71-91%) and AUDIT-C (95%), with high specificity (71-89%, 73-83% and 85%, respectively). CAGE and SMAST performed poorly. Sensitivity of AUDIT-C at score >or=3 was high for past year alcohol dependence (100%) or alcohol use disorder (96%) with moderate specificity (71% each). For life-time alcohol dependency the AUDIT at score >or=8 performed poorly. T-ACE, TWEAK and AUDIT-C show promise for screening for risk drinking, and AUDIT-C may also be useful for identifying alcohol dependency or abuse. However, their performance as stand-alone tools is uncertain, and further evaluation of questionnaires for prenatal alcohol use is warranted.

  14. Unmet clinical needs in cervical cancer screening.

    PubMed

    Rao, Jianyu; Escobar-Hoyos, Luisa; Shroyer, Kenneth R

    2016-01-01

    Cancer rates worldwide are expected to increase disproportionally in coming decades relative to the projected increase in population, especially in the developing world. The general unavailability of the Pap test and the cost of the HPV test in the developing world have precluded the deployment of effective cervical cancer screening programs in many developing countries. Recent improvements in testing technology arise from a need to overcome the significant limitations of the Pap test and HPV test, but results require first-world technology and validation. Developing countries, where cervical cancer remains one of the most important causes of cancer death, have the greatest need for an affordable, easy-to-use, and highly reliable cancer screening method that can return a diagnosis through efficient laboratory analysis or, more easily, at a woman's point of care. While research, testing, and vaccine improvements in recent years continue to lower the incidence of cervical cancer in some developed countries such as the U.S., HPV testing research needs to do more than test for the presence of virus. The tests must determine the presence and progression of cervical disease. Tests should be more sensitive and specific than Pap tests and Pap-related tests, and should be accurate in more than 90 percent of cases. Tests also need to be low-cost, objective, and easy to perform so screening programs can be widely implemented in developing countries where the need for a better cervical cancer screening test is highest. Such tests may be available through the recent advances in specific biomarkers of cervical cancer and multiplex detection technologies. Development of the next generation of cervical cancer tests that are more specific, sensitive, and informative than the traditional Pap or HPV test will make a significant impact on the reduction of cervical cancer worldwide.

  15. A study of the factors affecting boundary layer two-dimensionality in wind tunnels

    NASA Technical Reports Server (NTRS)

    Mehta, R. D.; Hoffmann, P. H.

    1986-01-01

    The effect of screens, honeycombs, and centrifugal blowers on the two-dimensionality of a boundary layer on the test section floors of low-speed blower tunnels is studied. Surveys of the spanwise variation in surface shear stress in three blower tunnels revealed that the main component responsible for altering the spanwise properties of the test section boundary layer was the last screen, thus confirming previous findings. It was further confirmed that a screen with varying open-area ratio, produced an unstable flow. However, contrary to popular belief, it was also found that for given incoming conditions and a screen free of imperfections, its open-area ratio alone was not enough to describe its performance. The effect of other geometric parameters such as the type of screen, honeycomb, and blower were investigated. In addition, the effect of the order of components in the settling chamber, and of wire Reynolds number were also studied.

  16. Organ donor screening practices for Strongyloides stercoralis infection among US organ procurement organizations.

    PubMed

    Abanyie, Francisca A; Valice, Emily; Delli Carpini, Kristin W; Gray, Elizabeth B; McAuliffe, Isabel; Chin-Hong, Peter V; Handali, Sukwan; Montgomery, Susan P; Huprikar, Shirish

    2018-03-07

    Targeted donor screening for strongyloidiasis performed at the time of organ procurement can prevent this life-threatening donor-derived infection. The Association of Organ Procurement Organizations surveyed members to determine the number of US organ procurement organizations (OPOs) performing donor screening for Strongyloides infection and their screening practices. All 58 OPOs responded to the survey. Only 6 (10%) currently screen donors for strongyloidiasis; most OPOs started 6-36 months before the survey and one started 6 years prior. All used risk-based criteria to determine which donors to screen, though the criteria varied among OPOs. A median of 56 donors have been screened at each OPO since initiating their screening programs, with a median of 2 infected donors (range 0-13) identified. Overall, 53 organs have been transplanted from 22 infected donors, including hearts, lungs, kidneys, and livers. Of 52 OPOs not currently screening, 20 had considered screening and one plans to start screening in the near future. Of those considering risk-based screening, most had not decided on the criteria. Uncertainty about the benefits of and guidelines for screening and misconceptions about the interpretation of test results were concerns shared by non-screening OPOs. Continued education and advocacy on the importance of targeted donor screening are needed. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  17. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Application of Shape Similarity in Pose Selection and Virtual Screening in CSARdock2014 Exercise.

    PubMed

    Kumar, Ashutosh; Zhang, Kam Y J

    2016-06-27

    To evaluate the applicability of shape similarity in docking-based pose selection and virtual screening, we participated in the CSARdock2014 benchmark exercise for identifying the correct docking pose of inhibitors targeting factor XA, spleen tyrosine kinase, and tRNA methyltransferase. This exercise provides a valuable opportunity for researchers to test their docking programs, methods, and protocols in a blind testing environment. In the CSARdock2014 benchmark exercise, we have implemented an approach that uses ligand 3D shape similarity to facilitate docking-based pose selection and virtual screening. We showed here that ligand 3D shape similarity between bound poses could be used to identify the native-like pose from an ensemble of docking-generated poses. Our method correctly identified the native pose as the top-ranking pose for 73% of test cases in a blind testing environment. Moreover, the pose selection results also revealed an excellent correlation between ligand 3D shape similarity scores and RMSD to X-ray crystal structure ligand. In the virtual screening exercise, the average RMSD for our pose prediction was found to be 1.02 Å, and it was one of the top performances achieved in CSARdock2014 benchmark exercise. Furthermore, the inclusion of shape similarity improved virtual screening performance of docking-based scoring and ranking. The coefficient of determination (r(2)) between experimental activities and docking scores for 276 spleen tyrosine kinase inhibitors was found to be 0.365 but reached 0.614 when the ligand 3D shape similarity was included.

  19. The Combined Utility of a Brief Functional Measure and Performance-Based Screening Test for Case Finding of Cognitive Impairment in Primary Healthcare.

    PubMed

    Chan, Qun Lin; Shaik, Muhammad Amin; Xu, Jing; Xu, Xin; Chen, Christopher Li-Hsian; Dong, YanHong

    2016-04-01

    Use of a total risk score (TRS) based on vascular and sociodemographic risk factors has been recommended to identify patients at risk of cognitive impairment. Moreover, combining screening tests has been reported to improve positive predictive values (PPV) for case finding of cognitive impairment. We investigated the utility of the conjunctive combination of the informant-based AD8 and the performance-based National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN) 5-minute protocol for the detection of cognitive impairment, defined by a clinical dementia rating (CDR) score ≥0.5, in patients at risk of cognitive impairment (TRS ≥3). Participants were recruited from 2 primary healthcare centers in Singapore and received the AD8, Montreal Cognitive Assessment, Mini-Mental State Examination, CDR, and a formal neuropsychological test battery. The scores for NINDS-CSN 5-minute protocol were extracted from the Montreal Cognitive Assessment items. Area under the receiver operating characteristics curve analyses were conducted to determine the discriminant indices of the screening instruments, the conjunctive combination (ie, screened positive on both tests), and the compensatory combination (ie, screened positive in either of or both tests). A total of 309 participants were recruited of whom 78.7% (n = 243) had CDR = 0 and 21.3% (n = 66) had CDR ≥0.5. The conjunctive combination of AD8 and NINDS-CSN 5-minute protocol achieved excellent PPV and acceptable sensitivity (PPV 91.7%, sensitivity 73.3%). The conjunctive combination of the AD8 and NINDS-CSN 5-minute protocol is brief and accurate, and hence, suitable for case finding of cognitive impairment (CDR ≥0.5) in patients screened positive on the TRS in primary healthcare centers. Copyright © 2016. Published by Elsevier Inc.

  20. Conjunctively screening of biocontrol agents (BCAs) against fusarium root rot and fusarium head blight caused by Fusarium graminearum.

    PubMed

    Wang, Lu-Yao; Xie, Yue-Shen; Cui, Yuan-Yu; Xu, Jianjun; He, Wei; Chen, Huai-Gu; Guo, Jian-Hua

    2015-08-01

    Fusarium root-rot and fusarium head blight are plant diseases caused by Fusarium sp. in different growth periods of wheat, bring heavy losses to crop production in China. This research is aiming to screen biocontrol agents conjunctively for controlling these two diseases at the same time, as well as evaluate our previous BCAs (Biological Control Agents) screening strategies in more complex situation, considering biocontrol is well concerned as an environmental-friendly plant disease controlling method. Totally 966 bacterial isolates were screened from different parts of wheat tissues, of which potential biocontrol values were detected according to their abilities in antagonism inhibition and secreting extracellular hydrolytic enzyme. Biocontrol tests against fusarium root rot and fusarium head blight were carried out on 37 bacterial isolates with potential biocontrol capacity after pre-selection through ARDRA- and BOX-PCR analysis on strains with high assessment points. We acquired 10 BCAs with obvious biocontrol efficacy (more than 40%) in greenhouse and field tests. Pseudomonas fluorescens LY1-8 performed well in both two tests (biocontrol efficacy: 44.62% and 58.31%), respectively. Overall, correlation coefficient is 0.720 between assessment values of 37 tested BCA strains and their biocontrol efficacy in trails against fusarium root rot; correlation coefficient is 0.806 between their assessment values and biocontrol efficacy in trails against fusarium head blight. We acquired 10 well-performed potential BCAs, especially P. fluorescens LY1-8 displayed good biocontrol capacity against two different diseases on wheat. Biocontrol efficacies results in both greenhouse and field tests showed high positive correlation with assessment values (0.720 and 0.806), suggesting that the BCAs screening and assessing strategy previously developed in our lab is also adaptable for conjunctively screening BCAs for controlling both root and shoot diseases on wheat caused by same fungal pathogen. Copyright © 2015 Elsevier GmbH. All rights reserved.

  1. Results obtained with a low cost software-based audiometer for hearing screening.

    PubMed

    Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis

    2013-07-01

     The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening.  To evaluate the TS audiometer for conducting audiometric screening.  A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated.  For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively.  The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

  2. Physiological Capacities: Estimating an Athlete's Potential.

    ERIC Educational Resources Information Center

    Lemon, Peter W. R.

    1982-01-01

    Several simple performance tests are described for assessing an athlete's major energy-producing capabilities. The tests are suitable for mass screening because they are easy to administer, require no sophisticated equipment, and can be done quickly. Information for evaluating test results is included. (PP)

  3. Routine DNA testing

    USDA-ARS?s Scientific Manuscript database

    Routine DNA testing. It’s done once you’ve Marker-Assisted Breeding Pipelined promising Qantitative Trait Loci within your own breeding program and thereby established the performance-predictive power of each DNA test for your germplasm under your conditions. By then you are ready to screen your par...

  4. Sarcopenia Screened by the SARC-F Questionnaire and Physical Performances of Elderly Women: A Cross-Sectional Study.

    PubMed

    Rolland, Yves; Dupuy, Charlotte; Abellan Van Kan, Gabor; Cesari, Matteo; Vellas, Bruno; Faruch, Marie; Dray, Cedric; de Souto Barreto, Philipe

    2017-10-01

    Screening for sarcopenia in daily practice can be challenging. Our objective was to explore whether the SARC-F questionnaire is a valid screening tool for sarcopenia (defined by the Foundation for the National Institutes of Health [FNIH] criteria). Moreover, we evaluated the physical performance of older women according to the SARC-F questionnaire. Cross-sectional study. Data from the Toulouse and Lyon EPIDémiologie de l'OStéoporose study (EPIDOS) on 3025 women living in the community (mean age: 80.5 ± 3.9 years), without a previous history of hip fracture, were assessed. The SARC-F self-report questionnaire score ranges from 0 to 10: a score ≥4 defines sarcopenia. The FNIH criteria uses handgrip strength (GS) and appendicular lean mass (ALM; assessed by DXA) divided by body mass index (BMI) to define sarcopenia. Outcome measures were the following performance-based tests: knee-extension strength, 6-m gait speed, and a repeated chair-stand test. The associations of sarcopenia with performance-based tests was examined using bootstrap multiple linear-regression models; adjusted R 2 determined the percentage variation for each outcome explained by the model. Prevalence of sarcopenia was 16.7% (n = 504) according to the SARC-F questionnaire and 1.8% (n = 49) using the FNIH criteria. Sensibility and specificity of the SARC-F to diagnose sarcopenia (defined by FNIH criteria) were 34% and 85%, respectively. Sarcopenic women defined by SARC-F had significantly lower physical performance than nonsarcopenic women. The SARC-F improved the ability to predict poor physical performance. The validity of the SARC-F questionnaire to screen for sarcopenia, when compared with the FNIH criteria, was limited. However, sarcopenia defined by the SARC-F questionnaire substantially improved the predictive value of clinical characteristics of patients to predict poor physical performance. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  5. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    PubMed

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with median follow-up of 8·16 years (IQR 7·56-8·56). 187 (3%) of 7155 screened participants were diagnosed with 196 screen-detected lung cancers, and another 34 (<1%; 19 [56%] in the first year after screening, and 15 [44%] in the second year after screening) were diagnosed with 35 interval cancers. For the three screening rounds combined, with a 2-year follow-up, sensitivity was 84·6% (95% CI 79·6-89·2), specificity was 98·6% (95% CI 98·5-98·8), positive predictive value was 40·4% (95% CI 35·9-44·7), and negative predictive value was 99·8% (95% CI 99·8-99·9). Retrospective assessment of the last screening CT and clinical CT in 34 patients with interval cancer showed that interval cancers were not visible in 12 (35%) cases. In the remaining cases, cancers were visible when retrospectively assessed, but were not diagnosed because of radiological detection and interpretation errors (17 [50%]), misclassification by the protocol (two [6%]), participant non-compliance (two [6%]), and non-adherence to protocol (one [3%]). Compared with screen-detected cancers, interval cancers were diagnosed at more advanced stages (29 [83%] of 35 interval cancers vs 44 [22%] of 196 screen-detected cancers diagnosed in stage III or IV; p<0·0001), were more often small-cell carcinomas (seven [20%] vs eight [4%]; p=0·003) and less often adenocarcinomas (nine [26%] vs 102 [52%]; p=0·005). Lung cancer screening in the NELSON trial yielded high specificity and sensitivity, with only a small number of interval cancers. The results of this study could be used to improve screening algorithms, and reduce the number of missed cancers. Zorgonderzoek Nederland Medische Wetenschappen and Koningin Wilhelmina Fonds. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Design and implementation of a controlled clinical trial to evaluate the effectiveness and efficiency of routine opt-out rapid human immunodeficiency virus screening in the emergency department.

    PubMed

    Haukoos, Jason S; Hopkins, Emily; Byyny, Richard L; Conroy, Amy A; Silverman, Morgan; Eisert, Sheri; Thrun, Mark; Wilson, Michael; Boyett, Brian; Heffelfinger, James D

    2009-08-01

    In 2006, the Centers for Disease Control and Prevention (CDC) released revised recommendations for performing human immunodeficiency virus (HIV) testing in health care settings, including implementing routine rapid HIV screening, the use of an integrated opt-out consent, and limited prevention counseling. Emergency departments (EDs) have been a primary focus of these efforts. These revised CDC recommendations were primarily based on feasibility studies and have not been evaluated through the application of rigorous research methods. This article describes the design and implementation of a large prospective controlled clinical trial to evaluate the CDC's recommendations in an ED setting. From April 15, 2007, through April 15, 2009, a prospective quasi-experimental equivalent time-samples clinical trial was performed to compare the clinical effectiveness and efficiency of routine (nontargeted) opt-out rapid HIV screening (intervention) to physician-directed diagnostic rapid HIV testing (control) in a high-volume urban ED. In addition, three nested observational studies were performed to evaluate the cost-effectiveness and patient and staff acceptance of the two rapid HIV testing methods. This article describes the rationale, methodologies, and study design features of this program evaluation clinical trial. It also provides details regarding the integration of the principal clinical trial and its nested observational studies. Such ED-based trials are rare, but serve to provide valid comparisons between testing approaches. Investigators should consider similar methodology when performing future ED-based health services research.

  7. Saccadic eye movement performance as an indicator of driving ability in elderly drivers.

    PubMed

    Schmitt, Kai-Uwe; Seeger, Rolf; Fischer, Hartmut; Lanz, Christian; Muser, Markus; Walz, Felix; Schwarz, Urs

    2015-01-01

    Regular checking of the fitness to drive of elderly car-license holders is required in some countries, and this will become increasingly important as more countries face aging populations. The present study investigated whether the analysis of saccadic eye movements could be used as a screening method for the assessment of driving ability. Three different paradigms (prosaccades, antisaccades, and visuovisual interactive (VVI) saccades) were used to test saccadic eye movements in 144 participants split into four groups: elderly drivers who came to the attention of road authorities for suspected lack of fitness to drive, a group of elderly drivers who served as a comparison group, a group of neurology patients with established brain lesion diagnoses, and a young comparison group. The group of elderly drivers with suspected deficits in driving skills also underwent a medical examination and a practical on-road driving test. The results of the saccadic eye tests of the different groups were compared. Antisaccade results indicated a strong link to driving behaviour: elderly drivers who were not fit to drive exhibited a poor performance on the antisaccade task and the performance in the VVI task was also clearly poorer in this group. Testing saccadic eye movements appears to be a promising and efficient method for screening large numbers of people such as elderly drivers. This study indicated a link between antisaccade performance and the ability to drive. Hence, measuring saccadic eye movements should be considered as a tool for screening the fitness to drive.

  8. Development of a language screening instrument for Swedish 4-year-olds.

    PubMed

    Lavesson, Ann; Lövdén, Martin; Hansson, Kristina

    2018-05-01

    The Swedish Program for health surveillance of preschool children includes screening of language and communication abilities. One important language screening is carried out at age 4 years as part of a general screening conducted by health nurses at child health centres. The instruments presently in use for this screening mainly focus on expressive phonology. This may result in both over-referral of children with phonological difficulties and under-referral of children with language disorders (LDs), involving difficulties with vocabulary, grammar and/or language comprehension. Previous research has proposed non-word repetition as a clinical marker for LD. It has also been found that higher predictive power is achieved when non-word repetition is combined with the assessment of lexical/semantic skills. Taking these findings into account, the construction of a language screening instrument may yield more adequate referrals to speech-language therapists (SLTs). To construct a new standardized language screening instrument for 4-year-olds and to test its properties. An instrument was developed and revised after piloting. A population of 352 children was screened at the regular 4-year check-up by 11 health nurses. The final sample consisted of 328 children aged 46-53 months (23% multilingual). Children performing below a preliminary cut-off were referred to an SLT (n = 52). Five SLTs carried out an assessment on average within 5 weeks using a gold standard language test battery. Children who screened negatively were followed up with a parent questionnaire at age 5;6. Thirty-one true-positives and 11 false-positives were identified after SLT assessment. A further six children were identified as false-negatives (two through referral to an SLT and four through parent questionnaire at age 5;6). A receiver-operating characteristics curve with a C statistic of .94 was calculated. Based on optimal cut-off, the sensitivity of the screening instrument was found to be .84, and specificity was .96. Multilingual children performed similar to monolingual children; boys performed significantly lower than girls; and children with a family history of language-related problems performed lower than those without. Interrater reliability was high, as was Cronbach's alpha. The screening instrument seems sufficiently valid for its purpose to identify children who need further assessment by an SLT. A follow-up study including SLT assessment for all children to check for false-negatives would be interesting in future, as would studies comparing results from the 4-year screening with those from earlier screens. © 2018 Royal College of Speech and Language Therapists.

  9. Newborn Screening and Cascade Testing for FMR1 Mutations

    PubMed Central

    Sorensen, Page L.; Gane, Louise W.; Yarborough, Mark; Hagerman, Randi; Tassone, Flora

    2014-01-01

    We describe an ongoing pilot project in which newborn screening (NBS) for FMR1 mutations and subsequent cascade testing are performed by the MIND Institute at the University of California, Davis Medical Center (UCDMC). To date, out of 3042 newborns initially screened, 44 extended family members have been screened by cascade testing of extended family members once a newborn is identified. 14 newborns (7 males and 7 females) and 27 extended family members (5 males and 22 females) have been identified with FMR1 mutations. Three family histories are discussed in detail, each demonstrating some benefits and risks of NBS and cascade testing for FMR1 mutations in extended family members. While we acknowledge inherent risks, we propose that with genetic counseling, clinical follow-up of identified individuals and cascade testing, newborn screening (NBS) has significant benefits. Treatment for individuals in the extended family who would otherwise not have received treatment can be beneficial. In addition, knowledge of carrier status can lead to lifestyle changes and prophylactic interventions that are likely to reduce the risk of late onset neurological or psychiatric problems in carriers. Also with identification of carrier family members through NBS, reproductive choices become available to those who would not have known that they were at risk to have offspring with fragile X syndrome. PMID:23239591

  10. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin

    PubMed Central

    Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.; Engelmann, Heather E.; Heredia-Langner, Alejandro; Hofstad, Beth A.; Hutchison, Janine R.; Jarman, Kristin; Melville, Angela M.; Victry, Kristin D.

    2017-01-01

    There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 108 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 107 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use. PMID:28192054

  11. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin.

    PubMed

    Bartholomew, Rachel A; Ozanich, Richard M; Arce, Jennifer S; Engelmann, Heather E; Heredia-Langner, Alejandro; Hofstad, Beth A; Hutchison, Janine R; Jarman, Kristin; Melville, Angela M; Victry, Kristin D; Bruckner-Lea, Cynthia J

    There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 10 8 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 10 7 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use.

  12. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    PubMed Central

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  13. Evidence on the Relationship between Firm-Based Screening and the Returns to Education

    ERIC Educational Resources Information Center

    Brown, Sarah; Sessions, John G.

    2006-01-01

    We explore the relationship between the signalling role of education and direct screening measures adopted by employers using a matched employee-employer data set drawn from the 1998 "Workplace Employee Relations Survey" for Great Britain. We identify which firms use personality/attitude and/or performance/competency tests during the…

  14. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  15. Screening of colorectal cancer: present and future.

    PubMed

    Maida, Marcello; Macaluso, Fabio Salvatore; Ianiro, Gianluca; Mangiola, Francesca; Sinagra, Emanuele; Hold, Georgina; Maida, Carlo; Cammarota, Giovanni; Gasbarrini, Antonio; Scarpulla, Giuseppe

    2017-12-01

    Colorectal cancer (CRC) is the third most common cancer in males and second in females, and the fourth most common cause of cancer death worldwide. Currently, about 60-70% of diagnosed cases in symptomatic patients are detected at an advanced stage of disease. Earlier stage detection through the use of screening strategies would allow for better outcomes in terms of reducing the disease burden. Areas covered: The aim of this paper is to review the current published evidence from literature which assesses the performance and effectiveness of different screening tests for the early detection of CRC. Expert commentary: Adequate screening strategies can reduce CRC incidence and mortality. In the last few decades, several tests have been proposed for CRC screening. To date, there is still insufficient evidence to identify which approach is definitively superior, and no screening strategy for CRC can therefore be defined as universally ideal. The best strategy would be the one that can be economically viable and to which the patient can adhere best to over time. The latest guidelines suggest colonoscopy every 10 years or annual fecal immuno-chemical test (FIT) for people with normal risk, while for individuals with high risk or hereditary syndromes specific recommendations are provided.

  16. Acoustic emission as a screening tool for ceramic matrix composites

    NASA Astrophysics Data System (ADS)

    Ojard, Greg; Goberman, Dan; Holowczak, John

    2017-02-01

    Ceramic matrix composites are composite materials with ceramic fibers in a high temperature matrix of ceramic or glass-ceramic. This emerging class of materials is viewed as enabling for efficiency improvements in many energy conversion systems. The key controlling property of ceramic matrix composites is a relatively weak interface between the matrix and the fiber that aids crack deflection and fiber pullout resulting in greatly increased toughness over monolithic ceramics. United Technologies Research Center has been investigating glass-ceramic composite systems as a tool to understand processing effects on material performance related to the performance of the weak interface. Changes in the interface have been shown to affect the mechanical performance observed in flexural testing and subsequent microstructural investigations have confirmed the performance (or lack thereof) of the interface coating. Recently, the addition of acoustic emission testing during flexural testing has aided the understanding of the characteristics of the interface and its performance. The acoustic emission onset stress changes with strength and toughness and this could be a quality tool in screening the material before further development and use. The results of testing and analysis will be shown and additional material from other ceramic matrix composite systems may be included to show trends.

  17. Sensitivity and validity of psychometric tests for assessing driving impairment: effects of sleep deprivation.

    PubMed

    Jongen, Stefan; Perrier, Joy; Vuurman, Eric F; Ramaekers, Johannes G; Vermeeren, Annemiek

    2015-01-01

    To assess drug induced driving impairment, initial screening is needed. However, no consensus has been reached about which initial screening tools have to be used. The present study aims to determine the ability of a battery of psychometric tests to detect performance impairing effects of clinically relevant levels of drowsiness as induced by one night of sleep deprivation. Twenty four healthy volunteers participated in a 2-period crossover study in which the highway driving test was conducted twice: once after normal sleep and once after one night of sleep deprivation. The psychometric tests were conducted on 4 occasions: once after normal sleep (at 11 am) and three times during a single night of sleep deprivation (at 1 am, 5 am, and 11 am). On-the-road driving performance was significantly impaired after sleep deprivation, as measured by an increase in Standard Deviation of Lateral Position (SDLP) of 3.1 cm compared to performance after a normal night of sleep. At 5 am, performance in most psychometric tests showed significant impairment. As expected, largest effect sizes were found on performance in the Psychomotor Vigilance Test (PVT). Large effects sizes were also found in the Divided Attention Test (DAT), the Attention Network Test (ANT), and the test for Useful Field of View (UFOV) at 5 and 11 am during sleep deprivation. Effects of sleep deprivation on SDLP correlated significantly with performance changes in the PVT and the DAT, but not with performance changes in the UFOV. From the psychometric tests used in this study, the PVT and DAT seem most promising for initial evaluation of drug impairment based on sensitivity and correlations with driving impairment. Further studies are needed to assess the sensitivity and validity of these psychometric tests after benchmark sedative drug use.

  18. Canadian women's attitudes toward noninvasive prenatal testing of fetal DNA in maternal plasma (.).

    PubMed

    Pariente, Gali; Hasan, Lara; Gadot, Yifat; De Souza, Leanne R; Lebovic, Gerald; Berger, Howard

    2016-12-01

    To determine the perceptions and attitudes of Canadian women to Noninvasive Prenatal Testing of fetal DNA. A designed questionnaire was administered to women attending the outpatient antenatal clinic at a tertiary urban hospital. Attitudes to current and new prenatal screening modalities were assessed using a five-point Likert scale. Bowker's test of symmetry was used to compare individual responses regarding the two screening modalities. Changes in women's responses pre- and post-delivery were also compared. One hundred and twenty-nine women were enrolled in this study. 88% of women state that they would perform prenatal screening via fetal DNA in the maternal plasma if available. When compared to conventional screening, significantly less women believe that the NIPT should be available upon request for non-medical traits (36.4% versus 60.4%, p < 0.001). When compared to their answer before delivery, more women agreed that screening with fetal DNA in maternal plasma could be used in a negative way to select for desired non-medical traits such as gender. The use of fetal DNA in the maternal plasma is widely accepted in our Canadian population as a future method of noninvasive prenatal screening despite recognition of certain ethical concerns. This information can be used when implementing new genetic screening programs.

  19. Self-collection based HPV testing for cervical cancer screening among women living with HIV in Uganda: a descriptive analysis of knowledge, intentions to screen and factors associated with HPV positivity.

    PubMed

    Mitchell, Sheona M; Pedersen, Heather N; Eng Stime, Evelyn; Sekikubo, Musa; Moses, Erin; Mwesigwa, David; Biryabarema, Christine; Christilaw, Jan; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S

    2017-01-13

    Women living with HIV (WHIV) are disproportionately impacted by cervical dysplasia and cancer. The burden is greatest in low-income countries where limited or no access to screening exists. The goal of this study was to describe knowledge and intentions of WHIV towards HPV self-collection for cervical cancer screening, and to report on factors related to HPV positivity among women who participated in testing. A validated survey was administered to 87 HIV positive women attending the Kisenyi Health Unit aged 30-69 years old, and data was abstracted from chart review. At a later date, self-collection based HPV testing was offered to all women. Specimens were tested for high risk HPV genotypes, and women were contacted with results and referred for care. Descriptive statistics, Chi Square and Fischer-exact statistical tests were performed. The vast majority of WHIV (98.9%) women did not think it necessary to be screened for cervical cancer and the majority of women had never heard of HPV (96.4%). However, almost all WHIV found self-collection for cervical cancer screening to be acceptable. Of the 87 WHIV offered self-collection, 40 women agreed to provide a sample at the HIV clinic. Among women tested, 45% were oncogenic HPV positive, where HPV 16 or 18 positivity was 15% overall. In this group of WHIV engaged in HIV care, there was a high prevalence of oncogenic HPV, a large proportion of which were HPV genotypes 16 or 18, in addition to low knowledge of HPV and cervical cancer screening. Improved education and cervical cancer screening for WHIV are sorely needed; self-collection based screening has the potential to be integrated with routine HIV care in this setting.

  20. Alcohol calibration of tests measuring skills related to car driving.

    PubMed

    Jongen, Stefan; Vuurman, Eric; Ramaekers, Jan; Vermeeren, Annemiek

    2014-06-01

    Medication and illicit drugs can have detrimental side effects which impair driving performance. A drug's impairing potential should be determined by well-validated, reliable, and sensitive tests and ideally be calibrated by benchmark drugs and doses. To date, no consensus has been reached on the issue of which psychometric tests are best suited for initial screening of a drug's driving impairment potential. The aim of this alcohol calibration study is to determine which performance tests are useful to measure drug-induced impairment. The effects of alcohol are used to compare the psychometric quality between tests and as benchmark to quantify performance changes in each test associated with potentially impairing drug effects. Twenty-four healthy volunteers participated in a double-blind, four-way crossover study. Treatments were placebo and three different doses of alcohol leading to blood alcohol concentrations (BACs) of 0.2, 0.5, and 0.8 g/L. Main effects of alcohol were found in most tests. Compared with placebo, performance in the Divided Attention Test (DAT) was significantly impaired after all alcohol doses and performance in the Psychomotor Vigilance Test (PVT) and the Balance Test was impaired with a BAC of 0.5 and 0.8 g/L. The largest effect sizes were found on postural balance with eyes open and mean reaction time in the divided attention and the psychomotor vigilance test. The preferable tests for initial screening are the DAT and the PVT, as these tests were most sensitive to the impairing effects of alcohol and being considerably valid in assessing potential driving impairment.

  1. Performance of the French version of the 4AT for screening the elderly for delirium in the emergency department.

    PubMed

    Gagné, Anne-Julie; Voyer, Philippe; Boucher, Valérie; Nadeau, Alexandra; Carmichael, Pierre-Hugues; Pelletier, Mathieu; Gouin, Emilie; Berthelot, Simon; Daoust, Raoul; Wilchesky, Machelle; Richard, Hélène; Pelletier, Isabelle; Ballard, Stephanie; Laguë, Antoine; Émond, Marcel

    2018-05-17

    CLINICIAN'S CAPSULE What is known about the topic? Delirium is frequent in older inpatients but often goes undetected. A short tool, the 4 A's Test (4AT), was created and validated for the detection of delirium. What did this study ask? This study compared the performance of the French version of the 4AT (4AT-F) with the Confusion Assessment Method (CAM) for the screening of delirium. What did this study find? The 4AT-F was a fast and reliable screening tool for delirium in the emergency department (ED). Why does this study matter to clinicians? Because of its quick administration time, it allows for systematic screening of patients at risk of delirium and cognitive impairment.

  2. The effectiveness of AGU-MCAT in predicting medical student performance in year one of the College of Medicine of the Arabian Gulf University.

    PubMed

    Alnasir, F A; Jaradat, A A

    2011-08-01

    To graduate good doctors, medical schools should adopt proper student procedures to select among applicant students. When selecting students, many medical colleges focus solely on their academic achievement on high school examinations, which do not reflect all, important attributes of student. For several years, the College of Medicine and Medical Sciences of the Arabian Gulf University has introduced and administered the AGU-MCAT (Arabian Gulf University Medical College Assessment Test) for screening student applicants. This study aimed to assess the ability of the AGU-MCAT to predict students' performance during their first year college study, as an example of one school's multi-dimensional admissions screening process. The AGU-MCAT is made up of three parts, including a written test on science, a test of students' English language skills and an interview. In the first part, students' science knowledge is tested with 100 multiple choice questions. The English exam assesses students. English reading and listening skills. Lastly, students are interviewed by two faculty members and one senior student to assess their personal qualities. The 138 students who passed the AGU-MCAT in September 2008 and matriculated in the school were studied. Their performance during Year One including their performance on exams in the various disciplines was compared to their achievement on the three AGU-MCAT components. AGU-MCAT's total mark and its science component had the highest linear relationship to students' performance in the various disciplines in Year One, while the strongest predictor of students' performance at the end of Year One was the AGU-MCAT's science test (R2=45.5%). Students' grades in high school did not predict their achievement in Year One. The AGU-MCAT used to screen applicants to the school also predicts students' performance during their first year of medical school.

  3. Screening for Lynch syndrome and referral to clinical genetics by selective mismatch repair protein immunohistochemistry testing: an audit and cost analysis.

    PubMed

    Colling, Richard; Church, David N; Carmichael, Juliet; Murphy, Lucinda; East, James; Risby, Peter; Kerr, Rachel; Chetty, Runjan; Wang, Lai Mun

    2015-12-01

    Lynch syndrome (LS) accounts for around 3% of colorectal cancers (CRCs) and is caused by germline mutations in mismatch repair (MMR) genes. Recently, screening strategies to identify patients with LS have become popular. We audited CRCs screened with MMR immunohistochemistry (IHC) in 2013. 209 tumours had MMR IHC performed at a cost of £12 540. 47/209 (21%) cases showed IHC loss of expression in at least one MMR protein. 28/44 cases with loss of MLH1 had additional BRAF V600E testing, at a cost of £5040. MMR IHC reduced the number of potential clinical genetics referrals from 209 to 47. BRAF mutation testing, performed in a subset of cases with MLH1 loss, further reduced this to 21. At a cost of £1340 per referral, this model of LS screening for clinical genetics referral had significant potential savings (£234 340) and can be easily implemented in parallel with MMR IHC done for prognostication in CRCs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.

    PubMed

    De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry

    2010-11-11

    Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.

  5. A noise control package for vibrating screens1),2)

    PubMed Central

    Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.

    2015-01-01

    Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468

  6. Accuracy of Nutritional Screening Tools in Assessing the Risk of Undernutrition in Hospitalized Children.

    PubMed

    Huysentruyt, Koen; Devreker, Thierry; Dejonckheere, Joachim; De Schepper, Jean; Vandenplas, Yvan; Cools, Filip

    2015-08-01

    The aim of the present study was to evaluate the predictive accuracy of screening tools for assessing nutritional risk in hospitalized children in developed countries. The study involved a systematic review of literature (MEDLINE, EMBASE, and Cochrane Central databases up to January 17, 2014) of studies on the diagnostic performance of pediatric nutritional screening tools. Methodological quality was assessed using a modified QUADAS tool. Sensitivity and specificity were calculated for each screening tool per validation method. A meta-analysis was performed to estimate the risk ratio of different screening result categories of being truly at nutritional risk. A total of 11 studies were included on ≥1 of the following screening tools: Pediatric Nutritional Risk Score, Screening Tool for the Assessment of Malnutrition in Paediatrics, Paediatric Yorkhill Malnutrition Score, and Screening Tool for Risk on Nutritional Status and Growth. Because of variation in reference standards, a direct comparison of the predictive accuracy of the screening tools was not possible. A meta-analysis was performed on 1629 children from 7 different studies. The risk ratio of being truly at nutritional risk was 0.349 (95% confidence interval [CI] 0.16-0.78) for children in the low versus moderate screening category and 0.292 (95% CI 0.19-0.44) in the moderate versus high screening category. There is insufficient evidence to choose 1 nutritional screening tool over another based on their predictive accuracy. The estimated risk of being at "true nutritional risk" increases with each category of screening test result. Each screening category should be linked to a specific course of action, although further research is needed.

  7. DEVELOPMENT OF A SCREENING PROTOCOL TO IDENTIFY INDIVIDUALS WITH DYSFUNCTIONAL BREATHING

    PubMed Central

    Kiesel, Kyle; Rhodes, Tonya; Mueller, Jacob; Waninger, Alyssa; Butler, Robert

    2017-01-01

    Introduction Dysfunctional breathing (DB) has been linked to health conditions including low back pain and neck pain and adversely effects the musculoskeletal system. Individuals with DB often have decreased pain thresholds and impaired motor control, balance, and movement. No single test or screen identifies DB, which is multi-dimensional, and includes biochemical, biomechanical, and psychophysiological components. Several tools assess and test for DB, but no screen exists to determine whether additional testing and assessment are indicated. Purpose/Background The purpose of this study was to develop a breathing screening procedure that could be utilized by fitness and healthcare providers to screen for the presence of disordered breathing. A diagnostic test study approach was utilized to establish the diagnostic accuracy of the newly developed screen for DB. Methods A convenience sample of 51 subjects (27 females, 27.0 years, BMI 23.3) were included. To test for DB related to the biochemical dimension, end-tidal CO2 (ETCO2) was measured with a capnography unit. To test for DB related to biomechanical dimension, the Hi-Lo test was utilized. To test for DB related to the psychophysiological dimension, the Self Evaluation of Breathing Symptoms Questionnaire (SEBQ) and Nijmegen questionnaires were utilized. Potential screening items that have been shown to be related to DB in previous research and that could be performed by non-health care personnel were utilized to create the index test including activity level, breath hold time (BHT), respiration rate, and the Functional Movement Screen (FMS™). Results There were no strong correlations between the three measures of DB. Five subjects had normal breathing, 14 failed at least one measure, 20 failed at least two, and 12 failed all three. To develop screening items for each dimension, data were examined for association with failure. BHT and a four-item mini-questionnaire were identified as the most closely associated variables with failure of all three dimensions. A BHT of < 25 seconds and four questions were combined and yielded a sensitivity of 0.89 (0.85-0.93) and a specificity of 0.60 (0.18-0.92) for clinical identification of DB. Conclusion Easily obtained clinical measures of BHT and four questions can be utilized to screen for the presence of DB. If the screen is passed, there is an 89% chance that DB is not present. If the screen is failed, further assessment is recommended. Level of Evidence 2b PMID:29181255

  8. The Interrelationship of Common Clinical Movement Screens: Establishing Population-Specific Norms in a Large Cohort of Military Applicants

    PubMed Central

    de la Motte, Sarah J.; Gribbin, Timothy C.; Lisman, Peter; Beutler, Anthony I.; Deuster, Patricia

    2016-01-01

    Context: Musculoskeletal injuries (MSK-Is) are a leading cause of missed duty time and morbidity in the military. Modifiable risk factors for MSK-Is, such as inadequate core stability, poor movement patterns, and dynamic balance deficits, have not been identified in military applicants on entering service. Objective: To establish normative functional movement data using a series of screens in military applicants entering basic training and explore relationships among several movement tests. Design: Cross-sectional study. Setting: Military Entrance Processing Station. Patients or Other Participants: A total of 1714 (1434 male, 280 female) military applicants entering the US Army (n = 546), Navy (n = 414), Air Force (n = 229), or Marine Corps (n = 525). Intervention(s): We conducted the Functional Movement Screen (FMS), Y-Balance Test (YBT), overhead squat (OHS), and Landing Error Scoring System (LESS). Movements were assessed using the scoring convention for each screen. Main Outcome Measure(s): The FMS, YBT, OHS, and LESS scores and associations among the movement screens as well as clinical meaningfulness. Results: A total of 1037 of the 1714 enrolled applicants were screened on the day they left for basic training. Normative means for this population were established: FMS = 14.7 ± 1.8, YBT anterior-reach difference = 3.1 ± 3.0 cm, mean YBT composite differences = 8.0 ± 6.8 cm, mean YBT composite percentage = 90.9% ± 8.3%, OHS errors = 5.0 ± 2.8, and LESS score = 5.7 ± 2.1. Backward regression results revealed that the YBT composite percentage was related to the FMS and OHS scores in males and to the FMS and LESS results in females. However, clinically meaningful relationships between the tests varied for both males and females. Conclusions: Sex-normative values for the FMS, YBT, OHS, and LESS screens were established for US military applicants, and some of the assessments overlapped. Overall, males performed better on the OHS and LESS and achieved a greater YBT composite percentage than females. The regression results revealed movement screen performance relationships that varied by sex and clinical meaningfulness. In future studies, we will determine if performance on any of the screens is associated with MSK-Is in basic trainees. PMID:27831746

  9. Thermal Protection System Aerothermal Screening Tests in HYMETS Facility

    NASA Technical Reports Server (NTRS)

    Szalai, Christine E.; Beck, Robin A. S.; Gasch, Matthew J.; Alumni, Antonella I.; Chavez-Garcia, Jose F.; Splinter, Scott C.; Gragg, Jeffrey G.; Brewer, Amy

    2011-01-01

    The Entry, Descent, and Landing (EDL) Technology Development Project has been tasked to develop Thermal Protection System (TPS) materials for insertion into future Mars Entry Systems. A screening arc jet test of seven rigid ablative TPS material candidates was performed in the Hypersonic Materials Environmental Test System (HYMETS) facility at NASA Langley Research Center, in both an air and carbon dioxide test environment. Recession, mass loss, surface temperature, and backface thermal response were measured for each test specimen. All material candidates survived the Mars aerocapture relevant heating condition, and some materials showed a clear increase in recession rate in the carbon dioxide test environment. These test results supported subsequent down-selection of the most promising material candidates for further development.

  10. Validity of FAA-approved color vision tests for class II and class III aeromedical screening.

    DOT National Transportation Integrated Search

    1993-09-01

    All clinical color vision tests currently used in the medical examination of pilots were studied regarding validity for prediction of performance on practical tests of ability to discriminate the aviation signal colors, red, green, and white given un...

  11. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    PubMed Central

    Nebie, Yacouba K.; Koivogui, Lamine; Abiola, Nadine; Vansteelandt, Amanda; Worrel, Mary C.; Shang, Judith; Murphy, Louise B.; Fitter, David L.; Marston, Barbara J.; Martel, Lise

    2017-01-01

    Background Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT) for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion. PMID:28879148

  12. To what extent will women accept HPV self-sampling for cervical cancer screening? A qualitative study conducted in Switzerland

    PubMed Central

    Fargnoli, Vanessa; Petignat, Patrick; Burton-Jeangros, Claudine

    2015-01-01

    Objectives Human papillomavirus self-sampling (self-HPV) is regarded as an alternative to Pap smear testing for women who do not participate in cervical cancer screening. This qualitative study aimed to determine women’s views on cervical cancer screening and the various obstacles to participation in screening, and to evaluate the perceived benefits and disadvantages of self-HPV. Method Twenty-four focus groups were conducted in 2012, with a total of 125 participants aged between 24 and 67 years. They were recruited through different channels, including flyers and posters, personal contacts, and an ongoing clinical trial focused on the unscreened population. Interview transcripts have been coded with the ATLAS.ti CAQDAS. Results Fifty-seven participants regularly attended screening and 68 had not been screened in the past 3 years. While some participants considered self-HPV as an acceptable screening method, others expressed concerns. Benefits included access, reduced costs, and time-saving. Disadvantages included the fear of not performing the test correctly, hurting oneself, and the accuracy of the test. Participants expressed concern that self-HPV would replace gynecological visits. Conclusion Self-HPV is not likely to rapidly or substantially modify women’s behaviors in regard to screening. While it may offer benefits in some specific situations, most women emphasized the advantages of regular gynecologist visits. PMID:26604830

  13. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    PubMed

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  14. Logistical Consideration in Computer-Based Screening of Astronaut Applicants

    NASA Technical Reports Server (NTRS)

    Galarza, Laura

    2000-01-01

    This presentation reviews the logistical, ergonomic, and psychometric issues and data related to the development and operational use of a computer-based system for the psychological screening of astronaut applicants. The Behavioral Health and Performance Group (BHPG) at the Johnson Space Center upgraded its astronaut psychological screening and selection procedures for the 1999 astronaut applicants and subsequent astronaut selection cycles. The questionnaires, tests, and inventories were upgraded from a paper-and-pencil system to a computer-based system. Members of the BHPG and a computer programmer designed and developed needed interfaces (screens, buttons, etc.) and programs for the astronaut psychological assessment system. This intranet-based system included the user-friendly computer-based administration of tests, test scoring, generation of reports, the integration of test administration and test output to a single system, and a complete database for past, present, and future selection data. Upon completion of the system development phase, four beta and usability tests were conducted with the newly developed system. The first three tests included 1 to 3 participants each. The final system test was conducted with 23 participants tested simultaneously. Usability and ergonomic data were collected from the system (beta) test participants and from 1999 astronaut applicants who volunteered the information in exchange for anonymity. Beta and usability test data were analyzed to examine operational, ergonomic, programming, test administration and scoring issues related to computer-based testing. Results showed a preference for computer-based testing over paper-and -pencil procedures. The data also reflected specific ergonomic, usability, psychometric, and logistical concerns that should be taken into account in future selection cycles. Conclusion. Psychological, psychometric, human and logistical factors must be examined and considered carefully when developing and using a computer-based system for psychological screening and selection.

  15. Beyond Critical Congenital Heart Disease: Newborn Screening Using Pulse Oximetry for Neonatal Sepsis and Respiratory Diseases in a Middle-Income Country.

    PubMed

    Jawin, Vida; Ang, Hak-Lee; Omar, Asma; Thong, Meow-Keong

    2015-01-01

    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country. In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively. Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low- and middle-income countries contemplating strategies to reduce neonatal mortality and morbidity. ASD, atrial septal defect; CCHD, critical congenital heart disease; CRP, C-reactive protein; CXR, chest radiographs; NDI, neurodevelopment impairment; PPHN, persistent pulmonary hypertension of the newborn; PDA, patent ductus arteriosus; PFO, patent foramen ovale; TGA, transposition of great artery; TTN, transient tachypnoea of the newborn; VSD, ventricular septal defect.

  16. Design and demonstrate the performance of cryogenic components representative of space vehicles: Start basket liquid acquisition device performance analysis

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The objective was to design, fabricate and test an integrated cryogenic test article incorporating both fluid and thermal propellant management subsystems. A 2.2 m (87 in) diameter aluminum test tank was outfitted with multilayer insulation, helium purge system, low-conductive tank supports, thermodynamic vent system, liquid acquisition device and immersed outflow pump. Tests and analysis performed on the start basket liquid acquisition device and studies of the liquid retention characteristics of fine mesh screens are discussed.

  17. Hepatitis C screening trends in a large integrated health system

    PubMed Central

    Linas, Benjamin P.; Hu, Haihong; Barter, Devra M.; Horberg, Michael

    2014-01-01

    Background As new hepatitis C virus (HCV) therapies emerge, only 1–12% of individuals are screened in the U.S. for HCV infection. Presently, HCV screening trends are unknown. Methods We utilized the Kaiser Permanente Mid-Atlantic States’ (KPMAS) data repository to investigate HCV antibody screening between 1/1/2003 and 12/31/2012. We identified the proportion screened for HCV and 5-year cumulative incidence of screening, the screening positivity rate, the provider types performing HCV screening, patient-level factors associated with being screened, and trends in screening over time. Results 444,594 patients met the inclusion criteria. Overall, 15.8% of the cohort was ever screened for HCV. Adult primary care and obstetrics and gynecology providers performed 75.9% of all screening. The overall test positivity rate was 3.8%. Screening was more frequent in younger age groups (p<0.0001) and those with a documented history of illicit drug use (p<0.0001). Patients with missing drug use history (46.7%) were least likely to be screened (p<0.0001). While the rate of HCV screening increased in the later years of the study, among those enrolled in KPMAS 2009–2012, only 11.8% were screened by the end of follow-up. Conclusion Screening for HCV is increasing, but remains incomplete. Targeting screening to those with a history of injection drug will not likely expand screening, as nearly half of patients have no documented drug use history. Routine screening is likely the most effective approach to expand HCV screening. PMID:24486288

  18. Hepatitis C screening trends in a large integrated health system.

    PubMed

    Linas, Benjamin P; Hu, Haihong; Barter, Devra M; Horberg, Michael

    2014-05-01

    As new hepatitis C virus (HCV) therapies emerge, only 1%-12% of individuals are screened in the US for HCV infection. Presently, HCV screening trends are unknown. We utilized the Kaiser Permanente Mid-Atlantic States' (KPMAS) data repository to investigate HCV antibody screening between January 1, 2003 and December 31, 2012. We identified the proportion screened for HCV and 5-year cumulative incidence of screening, the screening positivity rate, the provider types performing HCV screening, patient-level factors associated with being screened, and trends in screening over time. There were 444,594 patients who met the inclusion criteria. Overall, 15.8% of the cohort was ever screened for HCV. Adult primary care and obstetrics and gynecology providers performed 75.9% of all screening. The overall test positivity rate was 3.8%. Screening was more frequent in younger age groups (P <.0001) and those with a documented history of illicit drug use (P <.0001). Patients with missing drug use history (46.7%) were least likely to be screened (P <.0001). While the rate of HCV screening increased in the later years of the study among those enrolled in KPMAS 2009-2012, only 11.8% were screened by the end of follow-up. Screening for HCV is increasing but remains incomplete. Targeting screening to those with a history of injection drug will not likely expand screening, as nearly half of patients have no documented drug use history. Routine screening is likely the most effective approach to expand HCV screening. Copyright © 2014. Published by Elsevier Inc.

  19. [Effects, safety and cost-benefit analysis of Down syndrome screening in first trimester].

    PubMed

    Shengmou, Lin; Min, Chen; Chenhong, Wang; Shengli, Li; Jiansheng, Xie; Hui, Yuan; Dinghao, Lin; Xiaoxia, Wu; Wei, Wang; Hongyun, Zhang; Haiyan, Tang

    2014-05-01

    To investigate the effects, safety and cost-benefit analysis of Down syndrome screening in first trimester. From January 2009 to December 2012, 43 729 pregnant women undergoing 3 methods of Down syndrome traditional screening strategies in Shenzhen Maternity and Child Healthcare Hospital were studied retrospectively, including in 17 502 cases in pregnancy associated plasma protein A (PAPP-A) and free β-hCG measured biochemistry screening, 14 080 cases in nuchal translucency (NT) screening and 12 147 cases in combined screening, meanwhile, 7 389 cases on non-invasive fetal trisomy test (NIFTY) were performed in Huada Gene Research Institute(BGI). The effects and safety of four screening strategies were assessed throughout a decision tree. The economical characters of each screening strategy were compared by cost-effectiveness analysis as well as cost-benefit analysis. (1) The effects of four strategies are: NIFTY > combined screening > NT screening > biochemistry screening. (2) The safety of four strategies are: NIFTY > combined screening > NT screening > biochemistry screening. (3) Cost-effectiveness analysis and cost-benefit analysis:the biochemistry screening has lowest cost-effectiveness ratio (CER) and highest cost-benefit ratio (CBR), which performed a better economical efficiency. The incremental CER of three traditional screening strategies are all less than the economical burden of Down syndrome.NIFTY has highest CER and negative net present value (NPV), NPV would be positive and CBR would be more than 1 if the price of NIFTY reduce to 1 434 Yuan. Combined screening possess best screening efficiency, while biochemistry screening was demonstrated more economical in traditional screening.NIFTY is the future of Down syndrome screening.

  20. Prospective phase II study evaluating the efficacy of swallow ability screening tests and pneumonia prevention using a team approach for elderly patients with gastric cancer.

    PubMed

    Miki, Yuichiro; Makuuchi, Rie; Honda, Shinsaku; Tokunaga, Masanori; Tanizawa, Yutaka; Bando, Etsuro; Kawamura, Taiichi; Yurikusa, Takashi; Tanuma, Akira; Terashima, Masanori

    2018-03-01

    Aging partly impairs swallowing function, which is considered a risk factor for postoperative pneumonia (PP). We evaluated the efficacy of a new team-based strategy to reduce the incidence of PP in elderly patients with gastric cancer. This single-center, prospective phase II study included elderly patients (≥75 years old) with gastric cancer undergoing gastric surgery. The primary endpoint was the incidence of Clavien-Dindo grade II or higher PP. Patients were initially screened using three swallowing function screening tests: a symptom questionnaire, the modified water swallow test (MSWT), and the repetitive saliva swallowing test (RSST). All patients were provided standard preoperative oral checks and care and simple neck muscle training. For patients who screened positive, a videofluorographic swallowing study was performed; if an abnormality was found, the patient was given intensive swallowing rehabilitation both pre- and postoperatively. Of 86 eligible patients enrolled, PP developed in 3 (3.5%). The 60% confidence interval of 1.8-6.3% had an upper limit below the prespecified threshold of 7.8%. Positive screening results were found for 19 patients (22.1%) on the symptom questionnaire, 3 (3.5%) on the MSWT, and 1 (1.2%) on the RSST. PP was not observed in any patients who screened positive. In conclusion, although the screening tests we adopted here were not sufficient to identify patients at high risk of aspiration pneumonia, perioperative interventions using a team approach might be effective in reducing the incidence of PP in elderly patients with gastric cancer.

  1. Molecular markers for colorectal cancer screening

    PubMed Central

    Dickinson, Brandon T.; Kisiel, John; Ahlquist, David A.; Grady, William M.

    2016-01-01

    Colorectal cancer (CRC), although a significant cause of morbidity and mortality worldwide, has seen a declining incidence and mortality in countries with programmatic screening. Fecal occult blood testing (FOBT) and endoscopic approaches are the predominant screening methods currently. The discovery of the adenoma→carcinoma sequence and a greater understanding of the genetic and epigenetic changes that drive the formation of CRC have contributed to innovative research to identify molecular markers for highly accurate, non-invasive screening tests for CRC. DNA, proteins, messenger RNA, and micro-RNA have all been evaluated. The observation of tumor cell exfoliation into the mucocellular layer of the colonic epithelium and proven stability of DNA in a harsh stool environment make stool DNA a particularly promising marker. The development of a clinically useful stool DNA test has required numerous technical advances, including optimization in DNA stabilization, the development of assays with high analytical sensitivity, and the identification of specific and broadly informative molecular markers. A multi-target stool DNA (MT-sDNA) test, which combines both mutant and methylated DNA markers and a fecal immunochemical test (FIT), recently performed favorably in a large cross-sectional validation study and has been approved by the US Food and Drug Administration (FDA) for the screening of asymptomatic, average risk individuals. The ultimate way in which molecular marker screening assays will be used in clinical practice will require additional studies to determine optimal screening intervals, factors affecting compliance, management of false positive results, and the use of these assays in high-risk populations, as well as other considerations. PMID:25994221

  2. Faster and economical screening for vancomycin-resistant enterococci by sequential use of chromogenic agar and real-time polymerase chain reaction.

    PubMed

    Tan, Thean Yen; Jiang, Boran; Ng, Lily Siew Yong

    2017-08-01

    Screening for vancomycin-resistant enterococci (VRE) by culture takes days to generate results, while polymerase chain reaction (PCR) testing directly from clinical specimens lacks specificity. The aims of this study were to develop a real-time PCR to detect and identify Enterococcus faecium, Enterococcus faecalis, and vanA and vanB genes, and to evaluate the impact of this PCR on test-reporting times when performing it directly from suspect VRE isolates present on screening chromogenic media. The tetraplex PCR primers were designed to amplify E. faecium, E. faecalis, and vanA and vanB genes, with melt-curve analysis of PCR products. Following analytical and clinical validation of the molecular assay, PCR testing was performed for target colonies present on VRE chromogenic media. PCR results were evaluated against conventional phenotypic identification and susceptibility testing, with the time to result being monitored for both modalities. A total of 519 colonies from clinical specimens were tested concurrently by real-time PCR and phenotypic methods. In all, 223 isolates were identified with phenotypic vancomycin resistance (vanA, n = 108; vanB, n = 105; non-vanA/vanB = 10), with complete agreement between PCR and phenotypic testing for vancomycin-resistant E. faecium and E. faecalis. The majority (88.6%) of PCR results were reported, on average, 24.8 hours earlier than those of phenotypic testing, with 68% reduction in total costs. The use of culture on selective media, followed by direct colony PCR confirmation allows faster and economical VRE screening. Copyright © 2015. Published by Elsevier B.V.

  3. Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples.

    PubMed

    Castro, Andréa Cauduro de; Borges, Luiz Gustavo dos Anjos; Souza, Ricardo da Silva de; Grudzinski, Melina; D'Azevedo, Pedro Alves

    2008-01-01

    Human Immunodeficiency Virus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and immunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS-Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 degrees C, -20 degrees C and -70 degrees C, while the second was composed of two negative and three positive samples stored at 37 degrees C (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.

  4. Computerized screening for cognitive impairment in patients with COPD.

    PubMed

    Campman, Carlijn; van Ranst, Dirk; Meijer, Jan Willem; Sitskoorn, Margriet

    2017-01-01

    COPD is associated with cognitive impairment. These impairments should be diagnosed, but due to time- and budget-reasons, they are often not investigated. The aim of this study is to examine the viability of a brief computerized cognitive test battery, Central Nervous System Vital Signs (CNSVS), in COPD patients. Patients with COPD referred to tertiary pulmonary rehabilitation were included. Cognitive functioning of patients was assessed with CNSVS before pulmonary rehabilitation and compared with age-corrected CNSVS norms. CNSVS is a 30 minute computerized test battery that includes tests of verbal and visual memory, psychomotor speed, processing speed, cognitive flexibility, complex attention, executive functioning, and reaction time. CNSVS was fully completed by 205 (93.2%, 105 females, 100 males) of the total group of patients (n=220, 116 females, 104 males). Z -tests showed that COPD patients performed significantly worse than the norms on all CNSVS cognitive domains. Slightly more than half of the patients (51.8%) had impaired functioning on 1 or more cognitive domains. Patients without computer experience performed significantly worse on CNSVS than patients using the computer frequently. The completion rate of CNSVS was high and cognitive dysfunctions measured with this screening were similar to the results found in prior research, including paper and pen cognitive tests. These results support the viability of this brief computerized cognitive screening in COPD patients, that may lead to better care for these patients. Cognitive performance of patients with little computer experience should be interpreted carefully. Future research on this issue is needed.

  5. Suppression of background noise in a transonic wind-tunnel test section

    NASA Technical Reports Server (NTRS)

    Schutzenhofer, L. A.; Howard, P. W.

    1975-01-01

    Some exploratory tests were recently performed in the transonic test section of the NASA Marshall Space Flight Center 14-in. wind tunnel to suppress the background noise. In these tests, the perforated walls of the test section were covered with fine wire screens. The screens eliminated the edge tones generated by the holes in the perforated walls and significantly reduced the tunnel background noise. The tunnel noise levels were reduced to such a degree by this simple modification at Mach numbers 0.75, 0.9, 1.1, 1.2, and 1.46 that the fluctuating pressure levels of a turbulent boundary layer could be measured on a 5-deg half-angle cone.

  6. The Impact of the Affordable Care Act on Funding for Newborn Screening Services.

    PubMed

    Costich, Julia F; Durst, Andrea L

    2016-01-01

    The Affordable Care Act requires most health plans to cover the federal Recommended Uniform Screening Panel of newborn screening (NBS) tests with no cost sharing. However, state NBS programs vary widely in both the number of mandated tests and their funding mechanisms, including a combination of state laboratory fees, third-party billing, and other federal and state funding. We assessed the potential impact of the Affordable Care Act coverage mandate on states' NBS funding. We performed an extensive review of the refereed literature, federal and state agency reports, relevant organizations' websites, and applicable state laws and regulations; interviewed 28 state and federal officials from August to December 2014; and then assessed the interview findings manually. Although a majority of states had well-established systems for including laboratory-based NBS tests in bundled charges for newborn care, billing practices for critical congenital heart disease and newborn hearing tests were less uniform. Most commonly, birthing facilities either prepaid the costs of laboratory-based tests when acquiring the filter paper kits, or the facilities paid for the tests when the kits were submitted. Some states had separate arrangements for billing Medicaid, and smaller facilities sometimes contracted with hearing test vendors that billed families separately. Although the Affordable Care Act coverage mandate may offset some state NBS funding for the screenings themselves, federal support is still required to assure access to the full range of NBS program services. Limiting reimbursement to the costs of screening tests alone would undermine the common practice of using screening charges to fund follow-up services counseling, and medical food or formula, particularly for low-income families.

  7. Analysis of EPA's endocrine screening battery and recommendations for further review.

    PubMed

    Schapaugh, Adam W; McFadden, Lisa G; Zorrilla, Leah M; Geter, David R; Stuchal, Leah D; Sunger, Neha; Borgert, Christopher J

    2015-08-01

    EPA's Endocrine Disruptor Screening Program Tier 1 battery consists of eleven assays intended to identify the potential of a chemical to interact with the estrogen, androgen, thyroid, or steroidogenesis systems. We have collected control data from a subset of test order recipients from the first round of screening. The analysis undertaken herein demonstrates that the EPA should review all testing methods prior to issuing further test orders. Given the frequency with which certain performance criteria were violated, a primary focus of that review should consider adjustments to these standards to better reflect biological variability. A second focus should be to provide detailed, assay-specific direction on when results should be discarded; no clear guidance exists on the degree to which assays need to be re-run for failing to meet performance criteria. A third focus should be to identify permissible differences in study design and execution that have a large influence on endpoint variance. Experimental guidelines could then be re-defined such that endpoint variances are reduced and performance criteria are violated less frequently. It must be emphasized that because we were restricted to a subset (approximately half) of the control data, our analyses serve only as examples to underscore the importance of a detailed, rigorous, and comprehensive evaluation of the performance of the battery. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Clinical Validity of hearScreen™ Smartphone Hearing Screening for School Children.

    PubMed

    Mahomed-Asmail, Faheema; Swanepoel, De Wet; Eikelboom, Robert H; Myburgh, Hermanus C; Hall, James

    2016-01-01

    The study aimed to determine the validity of a smartphone hearing screening technology (hearScreen™) compared with conventional screening audiometry in terms of (1) sensitivity and specificity, (2) referral rate, and (3) test time. One thousand and seventy school-age children in grades 1 to 3 (8 ± 1.1 average years) were recruited from five public schools. Children were screened twice, once using conventional audiometry and once with the smartphone hearing screening. Screening was conducted in a counterbalanced sequence, alternating initial screen between conventional or smartphone hearing screening. No statistically significant difference in performance between techniques was noted, with smartphone screening demonstrating equivalent sensitivity (75.0%) and specificity (98.5%) to conventional screening audiometry. While referral rates were lower with the smartphone screening (3.2 vs. 4.6%), it was not significantly different (p > 0.05). Smartphone screening (hearScreen™) was 12.3% faster than conventional screening. Smartphone hearing screening using the hearScreen™ application is accurate and time efficient.

  9. Insights into Inpatients with Poor Vision: A High Value Proposition

    PubMed Central

    Press, Valerie G.; Matthiesen, Madeleine I.; Ranadive, Alisha; Hariprasad, Seenu M.; Meltzer, David O.; Arora, Vineet M.

    2015-01-01

    Background Vision impairment is an under-recognized risk factor for adverse events among hospitalized patients, yet vision is neither routinely tested nor documented for inpatients. Low-cost ($8 and up) non-prescription ‘readers’ may be a simple, high-value intervention to improve inpatients’ vision. We aimed to study initial feasibility and efficacy of screening and correcting inpatients’ vision. Methods From June 2012 through January 2014 we began testing whether participants’ vision corrected with non-prescription lenses for eligible participants failing a vision screen (Snellen chart) performed by research assistants (RAs). Descriptive statistics and tests of comparison, including t-tests and chi-squared tests, were used when appropriate. All analyses were performed using Stata version 12 (StataCorps, College Station, TX). Results Over 800 participants’ vision was screened (n=853). Older (≥65 years; 56%) participants were more likely to have insufficient vision than younger (<65 years; 28%; p<0.001). Non-prescription readers corrected the majority of eligible participants’ vision (82%, 95/116). Discussion Among an easily identified sub-group of inpatients with poor vision, low-cost ‘readers’ successfully corrected most participants’ vision. Hospitalists and other clinicians working in the inpatient setting can play an important role in identifying opportunities to provide high-value care related to patients’ vision. PMID:25755206

  10. Acceptability and validity of older driver screening with the DrivingHealth Inventory.

    PubMed

    Edwards, Jerri D; Leonard, Kathleen M; Lunsman, Melissa; Dodson, Joan; Bradley, Stacy; Myers, Charlsie A; Hubble, Bridgette

    2008-05-01

    Research has indicated that technology can be effectively used to identify high-risk older drivers. However, adaptation of such technology has been limited. Researchers debate whether older drivers represent a safety problem as well as whether they should be screened for driving fitness. The present study examined how drivers feel regarding technological screening and mandatory state testing. The validity and acceptability of a new technological screening battery for identifying high-risk drivers, the DrivingHealth Inventory (DHI), was also evaluated. In a sample of 258 Alabama drivers aged 18-87, older drivers performed significantly worse than younger drivers on sensory, cognitive, and physical subtests of the DHI, and older drivers with a crash history performed worse than older drivers without crashes. Regardless of age, 90% of participants supported states requiring screening for older drivers' license renewal. The majority of the participants (72%) supported use of technological screening batteries such as the DHI as a driver screening tool. Considering the acceptability and potential efficacy of the DHI, it may be a useful tool in evaluating driving fitness among older adults.

  11. Flexible sigmoidoscopy versus faecal occult blood testing for colorectal cancer screening in asymptomatic individuals.

    PubMed

    Holme, Øyvind; Bretthauer, Michael; Fretheim, Atle; Odgaard-Jensen, Jan; Hoff, Geir

    2013-10-01

    Colorectal cancer is the third most frequent cancer in the world. As the sojourn time for this cancer is several years and a good prognosis is associated with early stage diagnosis, screening has been implemented in a number of countries. Both screening with faecal occult blood test and flexible sigmoidoscopy have been shown to reduce mortality from colorectal cancer in randomised controlled trials. The comparative effectiveness of these tests on colorectal cancer mortality has, however, never been evaluated, and controversies exist over which test to choose. To compare the effectiveness of screening for colorectal cancer with flexible sigmoidoscopy to faecal occult blood testing. We searched MEDLINE and EMBASE (November 16, 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 11) and reference lists for eligible studies. Randomised controlled trials comparing screening with flexible sigmoidoscopy or faecal occult blood testing to each other or to no screening. Only studies reporting mortality from colorectal cancer were included. Faecal occult blood testing had to be repeated (annually or biennially). Data retrieval and assessment of risk of bias were performed independently by two review authors. Standard meta-analyses using a random-effects model were conducted for flexible sigmoidoscopy and faecal occult blood testing (FOBT) separately and we calculated relative risks with 95% confidence intervals (CI). We used a Bayesian approach (a contrast-based network meta-analysis method) for indirect analyses and presented the results as posterior median relative risk with 95% credibility intervals. We assessed the quality of evidence using GRADE. We identified nine studies comprising 338,467 individuals randomised to screening and 405,919 individuals to the control groups. Five studies compared flexible sigmoidoscopy to no screening and four studies compared repetitive guaiac-based FOBT (annually and biennially) to no screening. We did not consider that study risk of bias reduced our confidence in our results. We did not identify any studies comparing the two screening methods directly. When compared with no screening, colorectal cancer mortality was lower with flexible sigmoidoscopy (relative risk 0.72; 95% CI 0.65 to 0.79, high quality evidence) and FOBT (relative risk 0.86; 95% CI 0.80 to 0.92, high quality evidence). In the analyses based on indirect comparison of the two screening methods, the relative risk of dying from colorectal cancer was 0.85 (95% credibility interval 0.72 to 1.01, low quality evidence) for flexible sigmoidoscopy screening compared to FOBT. No complications occurred after the FOBT test itself, but 0.03% of participants suffered a major complication after follow-up. Among more than 60,000 flexible sigmoidoscopy screening procedures and almost 6000 work-up colonoscopies, a major complication was recorded in 0.08% of participants. Adverse event data should be interpreted with caution as the reporting of adverse effects was incomplete. There is high quality evidence that both flexible sigmoidoscopy and faecal occult blood testing reduce colorectal cancer mortality when applied as screening tools. There is low quality indirect evidence that screening with either approach reduces colorectal cancer deaths more than the other. Major complications associated with screening require validation from studies with more complete reporting of harms

  12. t4 workshop report--lessons learned, challenges, and opportunities: the U.S. Endocrine Disruptor Screening Program.

    PubMed

    Juberg, Daland R; Borghoff, Susan J; Becker, Richard A; Casey, Warren; Hartung, Thomas; Holsapple, Michael P; Marty, M Sue; Mihaich, Ellen M; Van Der Kraak, Glen; Wade, Michael G; Willett, Catherine E; Andersen, Melvin E; Borgert, Christopher J; Coady, Katherine K; Dourson, Michael L; Fowle, John R; Gray, L Earl; Lamb, James C; Ortego, Lisa S; Schug, Thaddeus T; Toole, Colleen M; Zorrilla, Leah M; Kroner, Oliver L; Patterson, Jacqueline; Rinckel, Lori A; Jones, Brett R

    2014-01-01

    In 1996, the U.S. Congress passed the Food Quality Protection Act and amended the Safe Drinking Water Act (SDWA) requiring the U.S. Environmental Protection Agency (EPA) to implement a screening program to investigate the potential of pesticide chemicals and drinking water contaminants to adversely affect endocrine pathways. Consequently, the EPA launched the Endocrine Disruptor Screening Program (EDSP) to develop and validate estrogen, androgen, and thyroid (EAT) pathway screening assays and to produce standardized and harmonized test guidelines for regulatory application. In 2009, the EPA issued the first set of test orders for EDSP screening and a total of 50 pesticide actives and 2 inert ingredients have been evaluated using the battery of EDSP Tier 1 screening assays (i.e., five in vitro assays and six in vivo assays). To provide a framework for retrospective analysis of the data generated and to collect the insight of multiple stakeholders involved in the testing, more than 240 scientists from government, industry, academia, and non-profit organizations recently participated in a workshop titled "Lessons Learned, Challenges, and Opportunities: The U.S. Endocrine Disruptor Screening Program." The workshop focused on the science and experience to date and was organized into three focal sessions: (a) Performance of the EDSP Tier 1 Screening Assays for Estrogen, Androgen, and Thyroid Pathways; (b) Practical Applications of Tier 1 Data; and (c) Indications and Opportunities for Future Endocrine Testing. A number of key learnings and recommendations related to future EDSP evaluations emanated from the collective sessions.

  13. Are there regional tendencies toward controversial screening practices? A study of prostate and breast cancer screening in a Medicare population.

    PubMed

    Raffin, Eric; Onega, Tracy; Bynum, Julie; Austin, Andrea; Carmichael, Donald; Bronner, Kristen; Goodney, Philip; Hyams, Elias S

    2017-10-01

    Prostate and breast cancer screening in older patients continue to be controversial. Balancing the desire for early detection with avoidance of over-diagnosis has led to competing and contradictory guidelines for both practices. Despite similarities, it is not known how these screening practices are related at the regional level. In this study, we examined how screening PSA and mammography are related within healthcare regions, and, to better understand what may be driving these practices, whether they are associated with local intensity of care. We performed a retrospective cross-sectional study of fee-for-service Medicare beneficiaries in 2012. For each of 306 hospital referral regions (HRRs), we calculated rates of PSA screening for men aged ≥68 years, as well as rates of screening mammography for women aged ≥75 years, adjusted for age and race. Additionally, we determined regional rates of "healthcare intensity", including spending on tests and procedures, and intensity of end-of-life care. Pearson correlations of adjusted rates were calculated within HRRs. The mean adjusted rate of PSA screening was 22%. The mean age of screened and unscreened patients was 75.0 and 77.4 years, respectively (p<0.0001). The mean adjusted rate of screening mammography was 23%; mean ages of screened and non-screened women were 79.95 and 83.67, respectively (p<0.0001). HRR-level PSA screening rates were independent of screening mammography rates (r=0.06, p=0.31). PSA screening rates were associated with spending on testing and procedures (r=0.42, p<0.0001) and various measures of intensity of EOL care (e.g. r=0.40, p<0.0001 for mechanical ventilator use). Screening mammography had low correlation with both health care spending and EOL care intensity measures (all r-values <0.3). Regional rates of PSA screening rates were independent of screening mammography, thus these practices appear to be driven by different factors. Unlike mammography, PSA screening was associated with local enthusiasm for testing and treatment. Efforts to reduce over-testing should contemplate these practices differently, and future research should examine the factors motivating these screening practices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Clinical Validation of Anyplex II HPV HR Detection Test for Cervical Cancer Screening in Korea.

    PubMed

    Jung, Sunkyung; Lee, Byungdoo; Lee, Kap No; Kim, Yonggoo; Oh, Eun-Jee

    2016-03-01

    The Anyplex II HPV HR detection kit (Seegene Inc, Seoul, Korea) is a new, multiplex, real-time polymerase chain reaction assay to detect individual 14 high-risk (HR) human papillomavirus (HPV) types in a single tube. To evaluate the clinical performance of the HPV HR kit in predicting high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse in cervical cancer screening. We analyzed 1137 cervical samples in Huro Path medium (CelltraZone, Seoul, Korea) from Korean women. The clinical performance of the HPV HR kit was compared with Hybrid Capture 2 (Qiagen, Valencia, California) using the noninferiority score test in a routine cervical cancer screening setting. The intralaboratory and interlaboratory agreements of HPV HR were also evaluated. Overall agreement between the 2 assays was 92.4% (1051 of 1137) with a κ value of 0.787. Clinical sensitivity of HPV HR for high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse was 94.4% (95% confidence interval [CI], 89.2-99.7) and 92.5% (95% CI, 84.3-100.0), respectively. The respective values for Hybrid Capture 2 were 93.1% (95% CI, 87.2-98.9) and 87.5% (95% CI, 77.3-99.7). Clinical sensitivity and specificity of HPV HR were not inferior to those of Hybrid Capture 2 (P = .005 and P = .04, respectively). The HPV HR showed good intralaboratory and interlaboratory reproducibility at 98.0% (κ = 0.953) and 97.4% (κ = 0.940), respectively. The HPV HR demonstrates comparable performance to the Hybrid Capture 2 test and can be useful for HPV-based cervical cancer screening testing.

  15. Radon and lung cancer: a cost-effectiveness analysis.

    PubMed Central

    Ford, E S; Kelly, A E; Teutsch, S M; Thacker, S B; Garbe, P L

    1999-01-01

    OBJECTIVES: This study examined the cost-effectiveness of general and targeted strategies for residential radon testing and mitigation in the United States. METHODS: A decision-tree model was used to perform a cost-effectiveness analysis of preventing radon-associated deaths from lung cancer. RESULTS: For a radon threshold of 4 pCi/L, the estimated costs to prevent 1 lung cancer death are about $3 million (154 lung cancer deaths prevented), or $480,000 per life-year saved, based on universal radon screening and mitigation, and about $2 million (104 lung cancer deaths prevented), or $330,000 per life-year saved, if testing and mitigation are confined to geographic areas at high risk for radon exposure. For mitigation undertaken after a single screening test and after a second confirmatory test, the estimated costs are about $920,000 and $520,000, respectively, to prevent a lung cancer death with universal screening and $130,000 and $80,000 per life-year for high risk screening. The numbers of preventable lung cancer deaths are 811 and 527 for universal and targeted approaches, respectively. CONCLUSIONS: These data suggest possible alternatives to current recommendations. PMID:10076484

  16. Factors affecting faecal immunochemical test positive rates: demographic, pathological, behavioural and environmental variables.

    PubMed

    Symonds, Erin L; Osborne, Joanne M; Cole, Stephen R; Bampton, Peter A; Fraser, Robert J L; Young, Graeme P

    2015-12-01

    Positive rates in faecal immunochemical test (FIT)-based colorectal cancer screening programmes vary, suggesting that differences between programmes may affect test results. We examined whether demographic, pathological, behavioural, and environmental factors affected haemoglobin concentration and positive rates where samples are mailed. A retrospective cohort study; 34,298 collection devices were sent, over five years, to screening invitees (median age 60.6). Participant demographics, temperature on sample postage day, and previous screening were recorded. Outcomes from colonoscopy performed within a year following FIT were collected. Multivariate logistic regression identified significant predictors of test positivity. Higher positive rate was independently associated with male gender, older age, lower socioeconomic status, and distally located neoplasia, and negatively associated with previous screening (p < 0.05). Older males had higher faecal haemoglobin concentrations and were less likely to have a false positive result at colonoscopy (p < 0.05). High temperature on the sample postage day was associated with reduced haemoglobin concentration and positivity rate (26-35℃: Odds ratio 0.78, 95% confidence interval 0.66-0.93), but was not associated with missed significant neoplasia at colonoscopy (p > 0.05). Haemoglobin concentrations, and therefore FIT positivity, were affected by factors that vary between screening programmes. Participant demographics and high temperature at postage had significant effects. The impact of temperature could be reduced by seasonal scheduling of invitations. The importance of screening, and following up positive test results, particularly in older males, should be promoted. © The Author(s) 2015.

  17. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...

  18. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...

  19. A comparison of relative toxicity rankings by some small-scale laboratory tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.

  20. Identification of Undiagnosed Inflammatory Arthritis in a Community Health-Fair Screen

    PubMed Central

    Deane, Kevin D.; Striebich, Christopher C.; Goldstein, Barbara L.; Derber, Lezlie A.; Parish, Mark C.; Feser, Marie L.; Hamburger, Elaine M.; Brake, Stacey; Belz, Cindy; Goddard, James; Norris, Jill M.; Karlson, Elizabeth W.; Holers, V. Michael

    2010-01-01

    Purpose The primary goals of this study were: 1) to identify individuals with undiagnosed inflammatory arthritis (IA) and rheumatoid arthritis (RA) in a community health-fair screen, and 2) to establish in a health-fair setting the diagnostic accuracy of combinations of the Connective Tissue Disease Screening Questionnaire (CSQ) and autoantibody testing for IA. Methods Screening for IA/RA was performed at health-fair sites using a combination of CSQ, joint examination, rheumatoid factor (RF) and anti-cyclic citrullinated (anti-CCP) antibody testing. IA was defined as ≥1 swollen joint/s suggestive of synovitis on joint examination by a trained clinician. Results Six-hundred one subjects were screened; 51.0% participating because of joint symptoms (pain, stiffness, or swelling). Eighty-four subjects (14.0%) had ≥1 swollen joint/s designated as IA on joint examination. Of the 601 subjects screened, 9 (1.5%) had IA and met ≥4 of 7 American College of Rheumatology criteria for RA but had no prior diagnosis of RA, and 15 (2.5%) had IA and RF and/or anti-CCP positivity, suggesting early RA. The diagnostic accuracy of combinations of CSQ and autoantibody testing for the identification of IA yielded maximal sensitivity, specificity, positive and negative predictive values of 95.3%, 99.2%, 71.4%, and 97.7%, respectively. Conclusions Health-fair screening may be an effective approach for the identification of individuals with undiagnosed IA/RA. A combination of CSQ and autoantibody testing alone has clinically useful diagnostic accuracy for the detection of IA. Decisions regarding which methodology to use for future health-fair IA/RA screening will depend on goals of screening and funding. PMID:19950306

  1. Development of enhancing agglutination reaction using gold nanoparticle for pre-transfusion testing.

    PubMed

    Choktaweesak, N; Krasathong, P; Ammaranond, P

    2016-10-01

    To explore an alternative way for antibody detection testing, the examination of gold nanoparticle solution for enhancing unexpected antibodies for pre-transfusion testing was investigated. Exposure of foreign antigens on red blood cells from transfusion can trigger the immune system to produce unexpected antibodies. This immunological response may cause the complication to future transfusion. For detection of unexpected antibodies, the antibody screening test is performed approximately 30-60 min. To reduce turnaround time, enhancing reagent, low-ionic strength solution (LISS), is widely used. However, cost of enhancing reagent is an issue which has concerned in resource limited countries. Gold nanoparticle solution can increase red blood cells agglutination reaction. To solve this issue, study of gold nanoparticle solution was investigated. Samples were performed comparing between LISS and gold nanoparticle solution at antiglobulin phase. After reading the agglutination reaction, supernatants were collected and measured at the optical density at 760 nm by spectrophotometer. The optical density in the tube of gold nanoparticle solution was higher than in the tube of 2-5% cell suspension and monoclonal antibody. It has been observed that gold nanoparticle solution enhanced the reaction of agglutination 98% while LISS enhanced the agglutination only 60·8%. Employing a commercially available enhancing reagent, parallel samples confirmed results providing validation of the assay. It approximately costs $1 US dollars compared to $30 for a commercially available reagent. The low cost and yet effective time-consuming test for antibody screening is a practical and viable solution alternative way for performing in antibody screening test in resource limited countries. © 2016 British Blood Transfusion Society.

  2. A user-operated test of suprathreshold acuity in noise for adult hearing screening: The SUN (Speech Understanding in Noise) test.

    PubMed

    Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando

    2014-09-01

    A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Effect of verbal instructions and image size on visual search strategies in basketball free throw shooting.

    PubMed

    Al-Abood, Saleh A; Bennett, Simon J; Hernandez, Francisco Moreno; Ashford, Derek; Davids, Keith

    2002-03-01

    We assessed the effects on basketball free throw performance of two types of verbal directions with an external attentional focus. Novices (n = 16) were pre-tested on free throw performance and assigned to two groups of similar ability (n = 8 in each). Both groups received verbal instructions with an external focus on either movement dynamics (movement form) or movement effects (e.g. ball trajectory relative to basket). The participants also observed a skilled model performing the task on either a small or large screen monitor, to ascertain the effects of visual presentation mode on task performance. After observation of six videotaped trials, all participants were given a post-test. Visual search patterns were monitored during observation and cross-referenced with performance on the pre- and post-test. Group effects were noted for verbal instructions and image size on visual search strategies and free throw performance. The 'movement effects' group saw a significant improvement in outcome scores between the pre-test and post-test. These results supported evidence that this group spent more viewing time on information outside the body than the 'movement dynamics' group. Image size affected both groups equally with more fixations of shorter duration when viewing the small screen. The results support the benefits of instructions when observing a model with an external focus on movement effects, not dynamics.

  4. Chemical compatibility screening results of plastic packaging to mixed waste simulants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigrey, P.J.; Dickens, T.G.

    1995-12-01

    We have developed a chemical compatibility program for evaluating transportation packaging components for transporting mixed waste forms. We have performed the first phase of this experimental program to determine the effects of simulant mixed wastes on packaging materials. This effort involved the screening of 10 plastic materials in four liquid mixed waste simulants. The testing protocol involved exposing the respective materials to {approximately}3 kGy of gamma radiation followed by 14 day exposures to the waste simulants of 60 C. The seal materials or rubbers were tested using VTR (vapor transport rate) measurements while the liner materials were tested using specificmore » gravity as a metric. For these tests, a screening criteria of {approximately}1 g/m{sup 2}/hr for VTR and a specific gravity change of 10% was used. It was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only VITON passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. It is anticipated that those materials with the lowest VTRs will be evaluated in the comprehensive phase of the program. For specific gravity testing of liner materials the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE were found to offer the greatest resistance to the combination of radiation and chemicals.« less

  5. Standard Setting in Specific-Purpose Language Testing: What Can a Qualitative Study Add?

    ERIC Educational Resources Information Center

    Manias, Elizabeth; McNamara, Tim

    2016-01-01

    This paper explores the views of nursing and medical domain experts in considering the standards for a specific-purpose English language screening test, the Occupational English Test (OET), for professional registration for immigrant health professionals. Since individuals who score performances in the test setting are often language experts…

  6. Performance index: An expeditious tool to screen for improved drought resistance in the Lathyrus genus.

    PubMed

    Silvestre, Susana; Araújo, Susana de Sousa; Vaz Patto, Maria Carlota; Marques da Silva, Jorge

    2014-07-01

    Some species of the Lathyrus genus are among the most promising crops for marginal lands, with high resilience to drought, flood, and fungal diseases, combined with high yields and seed nutritional value. However, lack of knowledge on the mechanisms underlying its outstanding performance and methodologies to identify elite genotypes has hampered its proper use in breeding. Chlorophyll a fast fluorescence transient (JIP test), was used to evaluate water deficit (WD) resistance in Lathyrus genus. Our results reveal unaltered photochemical values for all studied genotypes showing resistance to mild WD. Under severe WD, two Lathyrus sativus genotypes showed remarkable resilience maintaining the photochemical efficiency, contrary to other genotypes studied. Performance index (PIABS) is the best parameter to screen genotypes with improved performance and grain production under WD. Moreover, we found that JIP indices are good indicators of genotypic grain production under WD. Quantum yield of electron transport (ϕEo) and efficiency with which trapped excitons can move electrons further than QA (ψ0) revealed as important traits related to improved photosynthetic performance and should be exploited in future Lathyrus germplasm improvements. The JIP test herein described showed to be an expeditious tool to screen and to identify elite genotypes with improved drought resistance.

  7. Performance and Safety Testing of Varta Li-Ion Polymer Cells

    NASA Technical Reports Server (NTRS)

    Patel, Pranav; Jeevarajan, Judith

    2009-01-01

    Varta Cell Characteristics: Voltage : 3.7 V Capacity : 1.21 Ah Dimensions : 5mm X 37mm X 38.5 mm MOSFET switches for Overvoltage and Undervoltage. Initial Screening Results 29 Cells delivered: Statistics on Ph ysical Screening: Thickness (mm): Average- 5.08; Weight(g)- 22.8938; OCV (V)- 3.787; CCV (V)- 3.491.

  8. Cost-Effectiveness of Different Cervical Screening Strategies in Islamic Republic of Iran: A Middle-Income Country with a Low Incidence Rate of Cervical Cancer.

    PubMed

    Nahvijou, Azin; Daroudi, Rajabali; Tahmasebi, Mamak; Amouzegar Hashemi, Farnaz; Rezaei Hemami, Mohsen; Akbari Sari, Ali; Barati Marenani, Ahmad; Zendehdel, Kazem

    2016-01-01

    Invasive cervical cancer (ICC) is the fourth most common cancer among women worldwide. Cervical screening programs have reduced the incidence and mortality rates of ICC. We studied the cost-effectiveness of different cervical screening strategies in the Islamic Republic of Iran, a Muslim country with a low incidence rate of ICC. We constructed an 11-state Markov model, in which the parameters included regression and progression probabilities, test characteristics, costs, and utilities; these were extracted from primary data and the literature. Our strategies included Pap smear screening and human papillomavirus (HPV) DNA testing plus Pap smear triaging with different starting ages and screening intervals. Model outcomes included lifetime costs, life years gained, quality-adjusted life years (QALY), and incremental cost-effectiveness ratios (ICERs). One-way sensitivity analysis was performed to examine the stability of the results. We found that the prevented mortalities for the 11 strategies compared with no screening varied from 26% to 64%. The most cost-effective strategy was HPV screening, starting at age 35 years and repeated every 10 years. The ICER of this strategy was $8,875 per QALY compared with no screening. We found that screening at 5-year intervals was also cost-effective based on GDP per capita in Iran. We recommend organized cervical screening with HPV DNA testing for women in Iran, beginning at age 35 and repeated every 10 or 5 years. The results of this study could be generalized to other countries with low incidence rates of cervical cancer.

  9. Cost-Effectiveness of Different Cervical Screening Strategies in Islamic Republic of Iran: A Middle-Income Country with a Low Incidence Rate of Cervical Cancer

    PubMed Central

    Nahvijou, Azin; Daroudi, Rajabali; Tahmasebi, Mamak; Amouzegar Hashemi, Farnaz; Rezaei Hemami, Mohsen; Akbari Sari, Ali; Barati Marenani, Ahmad; Zendehdel, Kazem

    2016-01-01

    Objective Invasive cervical cancer (ICC) is the fourth most common cancer among women worldwide. Cervical screening programs have reduced the incidence and mortality rates of ICC. We studied the cost-effectiveness of different cervical screening strategies in the Islamic Republic of Iran, a Muslim country with a low incidence rate of ICC. Methods We constructed an 11-state Markov model, in which the parameters included regression and progression probabilities, test characteristics, costs, and utilities; these were extracted from primary data and the literature. Our strategies included Pap smear screening and human papillomavirus (HPV) DNA testing plus Pap smear triaging with different starting ages and screening intervals. Model outcomes included lifetime costs, life years gained, quality-adjusted life years (QALY), and incremental cost-effectiveness ratios (ICERs). One-way sensitivity analysis was performed to examine the stability of the results. Results We found that the prevented mortalities for the 11 strategies compared with no screening varied from 26% to 64%. The most cost-effective strategy was HPV screening, starting at age 35 years and repeated every 10 years. The ICER of this strategy was $8,875 per QALY compared with no screening. We found that screening at 5-year intervals was also cost-effective based on GDP per capita in Iran. Conclusion We recommend organized cervical screening with HPV DNA testing for women in Iran, beginning at age 35 and repeated every 10 or 5 years. The results of this study could be generalized to other countries with low incidence rates of cervical cancer. PMID:27276093

  10. Expert opinion on best practice guidelines and competency framework for visual screening in children.

    PubMed

    Lança, Carla

    2013-09-01

    Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.

  11. Urine tests for Down's syndrome screening.

    PubMed

    Alldred, S Kate; Guo, Boliang; Takwoingi, Yemisi; Pennant, Mary; Wisniewski, Susanna; Deeks, Jonathan J; Neilson, James P; Alfirevic, Zarko

    2015-12-10

    Down's syndrome occurs when a person has three copies of chromosome 21, or the specific area of chromosome 21 implicated in causing Down's syndrome, rather than two. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life. The risk of a Down's syndrome affected pregnancy increases with advancing maternal age.Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. To estimate and compare the accuracy of first and second trimester urine markers for the detection of Down's syndrome. We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), EMBASE (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2011, Issue 7), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (archived 2007), Health Services Research Projects in Progress database (25 August 2011). We studied reference lists and published review articles. Studies evaluating tests of maternal urine in women up to 24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC (receiver operating characteristic) meta-analytical methods to analyse test performance and compare test accuracy. We performed analysis of studies allowing direct comparison between tests. We investigated the impact of maternal age on test performance in subgroup analyses. We included 19 studies involving 18,013 pregnancies (including 527 with Down's syndrome). Studies were generally of high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Twenty-four test combinations were evaluated formed from combinations of the following seven different markers with and without maternal age: AFP (alpha-fetoprotein), ITA (invasive trophoblast antigen), ß-core fragment, free ßhCG (beta human chorionic gonadotrophin), total hCG, oestriol, gonadotropin peptide and various marker ratios. The strategies evaluated included three double tests and seven single tests in combination with maternal age, and one triple test, two double tests and 11 single tests without maternal age. Twelve of the 19 studies only evaluated the performance of a single test strategy while the remaining seven evaluated at least two test strategies. Two marker combinations were evaluated in more than four studies; second trimester ß-core fragment (six studies), and second trimester ß-core fragment with maternal age (five studies).In direct test comparisons, for a 5% false positive rate (FPR), the diagnostic accuracy of the double marker second trimester ß-core fragment and oestriol with maternal age test combination was significantly better (ratio of diagnostic odds ratio (RDOR): 2.2 (95% confidence interval (CI) 1.1 to 4.5), P = 0.02) (summary sensitivity of 73% (CI 57 to 85) at a cut-point of 5% FPR) than that of the single marker test strategy of second trimester ß-core fragment and maternal age (summary sensitivity of 56% (CI 45 to 66) at a cut-point of 5% FPR), but was not significantly better (RDOR: 1.5 (0.8 to 2.8), P = 0.21) than that of the second trimester ß-core fragment to oestriol ratio and maternal age test strategy (summary sensitivity of 71% (CI 51 to 86) at a cut-point of 5% FPR). Tests involving second trimester ß-core fragment and oestriol with maternal age are significantly more sensitive than the single marker second trimester ß-core fragment and maternal age, however, there were few studies. There is a paucity of evidence available to support the use of urine testing for Down's syndrome screening in clinical practice where alternatives are available.

  12. Scheme for the selection of measurement uncertainty models in blood establishments' screening immunoassays.

    PubMed

    Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda

    2015-02-01

    Blood establishments routinely perform screening immunoassays to assess safety of the blood components. As with any other screening test, results have an inherent uncertainty. In blood establishments the major concern is the chance of false negatives, due to its possible impact on patients' health. This article briefly reviews GUM and diagnostic accuracy models for screening immunoassays, recommending a scheme to support the screening laboratories' staffs on the selection of a model considering the intended use of the screening results (i.e., post-transfusion safety). The discussion is grounded on a "risk-based thinking", risk being considered from the blood donor selection to the screening immunoassays. A combination of GUM and diagnostic accuracy models to evaluate measurement uncertainty in blood establishments is recommended. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Screening for Colorectal Cancer With Fecal Immunochemical Testing With and Without Postpolypectomy Surveillance Colonoscopy: A Cost-Effectiveness Analysis.

    PubMed

    Greuter, Marjolein J E; de Klerk, Clasine M; Meijer, Gerrit A; Dekker, Evelien; Coupé, Veerle M H

    2017-10-17

    Population-based screening to prevent colorectal cancer (CRC) death is effective, but the effectiveness of postpolypectomy surveillance is unclear. To evaluate the additional benefit in terms of cost-effectiveness of colonoscopy surveillance in a screening setting. Microsimulation using the ASCCA (Adenoma and Serrated pathway to Colorectal CAncer) model. Dutch CRC screening program and published literature. Asymptomatic persons aged 55 to 75 years without a prior CRC diagnosis. Lifetime. Health care payer. Fecal immunochemical test (FIT) screening with colonoscopy surveillance performed according to the Dutch guideline was simulated. The comparator was no screening or surveillance. FIT screening without colonoscopy surveillance and the effect of extending surveillance intervals were also evaluated. CRC burden, colonoscopy demand, life-years, and costs. FIT screening without surveillance reduced CRC mortality by 50.4% compared with no screening or surveillance. Adding surveillance to FIT screening reduced mortality by an additional 1.7% to 52.1% but increased lifetime colonoscopy demand by 62% (from 335 to 543 colonoscopies per 1000 persons) at an additional cost of €68 000, for an increase of 0.9 life-year. Extending the surveillance intervals to 5 years reduced CRC mortality by 51.8% and increased colonoscopy demand by 42.7% compared with FIT screening without surveillance. In an incremental analysis, incremental cost-effectiveness ratios (ICERs) for screening plus surveillance exceeded the Dutch willingness-to-pay threshold of €36 602 per life-year gained. When using a parameter set representing low colorectal lesion prevalence or when colonoscopy costs were halved or colorectal lesion incidence was doubled, screening plus surveillance became cost-effective compared with screening without surveillance. Limited data on FIT performance and background CRC risk in the surveillance population. Adding surveillance to FIT screening is not cost-effective based on the Dutch ICER threshold and substantially increases colonoscopy demand. Extending surveillance intervals to 5 years would decrease colonoscopy demand without substantial loss of effectiveness. Alpe d'HuZes, Dutch Cancer Society, and Stand Up To Cancer.

  14. Screening strategies for tubal factor subfertility.

    PubMed

    den Hartog, J E; Lardenoije, C M J G; Severens, J L; Land, J A; Evers, J L H; Kessels, A G H

    2008-08-01

    Different screening strategies exist to estimate the risk of tubal factor subfertility, preceding laparoscopy. Three screening strategies, comprising Chlamydia trachomatis IgG antibody testing (CAT), high-sensitivity C-reactive protein (hs-CRP) testing and hysterosalpingography (HSG), were explored using laparoscopy as reference standard and the occurrence of a spontaneous pregnancy as a surrogate marker for the absence of tubal pathology. In this observational study, 642 subfertile women, who underwent tubal testing, participated. Data on serological testing, HSG, laparoscopy and interval conception were collected. Multiple imputations were used to compensate for missing data. Strategy A (HSG) has limited value in estimating the risk of tubal pathology. Strategy B (CAT-->HSG) shows that CAT significantly discerns patients with a high versus low risk of tubal pathology, whereas HSG following CAT has no additional value. Strategy C (CAT-->hs-CRP-->HSG) demonstrates that hs-CRP may be valuable in CAT-positive patients only and HSG has no additional value. CAT is proposed as first screening test for tubal factor subfertility. In CAT-negative women, HSG may be performed because of its high specificity and fertility-enhancing effect. In CAT-positive women, hs-CRP seems promising, whereas HSG has no additional value. The position and timing of laparoscopy deserves critical reappraisal.

  15. Anxiety and Depression Screening for Youth in a Primary Care Population

    PubMed Central

    Katon, Wayne; Joan, Russo; Richardson, Laura; McCauley, Elizabeth; Lozano, Paula

    2008-01-01

    Objective Prior studies have shown a low rate of accurate identification by primary care physicians of mental health disorders in youth. This study tested the psychometric properties of two brief mental health screening questionnaires, the Mood and Feelings Questionnaire – Short Form (MFQ-SF) and Childhood Anxiety Sensitivity Index (ASI), in a large sample of youth. Methods In a sample of 1375 youth age 11 to 17 (779 with asthma, 596 randomly selected controls) enrolled in an HMO, the psychometric properties (optimum cutoffs on Receiver Operating Curve (ROC) curves, sensitivity, specificity, positive and negative predictive values) of two brief anxiety and depression screens were examined versus a “gold standard” structured psychiatric interview. Results Both the MFQ-SF and ASI performed well on ROC analysis for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better on ROC analysis than the ASI for youth with major depression (area under the curve of 0.84 vs 0.77). For screening youth with anxiety disorders ROC curves showed that both the MFQ-SF and ASI only performed in the fair range (area under the curve of 0.76). Conclusion The MFQ-SF and ASI are two relatively brief questionnaires that performed well for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better than the ASI for screening youth with major depression. Use of these instruments could increase the accuracy of identification of mental health disorders in youth by primary care physicians. PMID:18501865

  16. Development of a Test of Suprathreshold Acuity in Noise in Brazilian Portuguese: A New Method for Hearing Screening and Surveillance

    PubMed Central

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light), “a hearing check would be advisable” (yellow light), and “no hearing difficulties” (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention. PMID:25247181

  17. Cell-free DNA testing in the maternal blood in high-risk pregnancies after first-trimester combined screening.

    PubMed

    Persico, Nicola; Boito, Simona; Ischia, Benedetta; Cordisco, Adalgisa; De Robertis, Valentina; Fabietti, Isabella; Periti, Enrico; Volpe, Paolo; Fedele, Luigi; Rembouskos, Georgios

    2016-03-01

    The objective of this study was to investigate a strategy for clinical implementation of cell-free DNA (cfDNA) testing in high-risk pregnancies after first-trimester combined screening. In 259 singleton pregnancies undergoing invasive testing after first-trimester combined screening, a maternal blood sample was sent to the laboratory Natera for cfDNA testing using a single-nucleotide polymorphism-based methodology. The cfDNA test provided a result in 249 (96.1%) pregnancies and, among these, identified as being at high risk 35 of 36 cases of trisomy 21, 13 of 13 with trisomy 18, five of five with trisomy 13 and three of four with sex chromosome aneuploidies. A policy of performing an invasive test in women with a combined risk of ≥1 in 10 or NT ≥4 mm and offering cfDNA testing to the remaining cases would detect all cases of trisomy 21, 18 or 13, 80% of sex aneuploidies and 62.5% of other defects and would avoid an invasive procedure in 82.4% of euploid fetuses. In high-risk pregnancies after combined screening, a policy of selecting a subgroup for invasive testing and another for cfDNA testing would substantially reduce the number of invasive procedures and retain the ability to diagnose most of the observed aneuploidies. © 2016 John Wiley & Sons, Ltd.

  18. Determinants of VIA (Visual Inspection of the Cervix After Acetic Acid Application) Positivity in Cervical Cancer Screening of Women in a Peri-Urban Area in Andhra Pradesh, India

    PubMed Central

    Vedantham, Haripriya; Silver, Michelle I.; Kalpana, B.; Rekha, C.; Karuna, B.P.; Vidyadhari, K.; Mrudula, S.; Ronnett, Brigitte M.; Vijayaraghavan, K.; Ramakrishna, Gayatri; Sowjanya, Pavani; Laxmi, Shantha; Shah, Keerti V.; Gravitt, Patti E.

    2010-01-01

    Objectives Visual inspection of the cervix after acetic acid application (VIA) is widely recommended as the method of choice in cervical cancer screening programs in resource-limited settings because of its simplicity and ability to link with immediate treatment. In testing the effectiveness of VIA, human papillomavirus DNA testing, and Pap cytology in a population-based study in a peri-urban area in Andhra Pradesh, India, we found the sensitivity of VIA for detection of cervical intraepithelial neoplasia grade 2 and worse (CIN2+) to be 26.3%, much lower than the 60% to 90% reported in the literature. We therefore investigated the determinants of VIA positivity in our study population. Methods We evaluated VIA positivity by demographics and reproductive history, results of clinical examination, and results from the other screening methods. Results Of the 19 women diagnosed with CIN2+, only 5 were positive by VIA (positive predictive value, 3.1%). In multivariate analysis, VIA positivity (12.74%) was associated with older age, positive Pap smear, visually apparent cervical inflammation, and interobserver variation. Cervical inflammation of unknown cause was present in 21.62% of women. In disease-negative women, cervical inflammation was associated with an increase in VIA positivity from 6.1% to 15.5% (P < 0.001). Among the six gynecologists who performed VIA, the positivity rate varied from 4% to 31%. Conclusions The interpretation of VIA is subjective and its performance cannot be readily evaluated against objective standards. Impact VIA is not a robust screening test and we caution against its use as the primary screening test in resource-limited regions. PMID:20447927

  19. Performance characteristics of a brief Family History Questionnaire to screen for Lynch syndrome in women with newly diagnosed endometrial cancer.

    PubMed

    Eiriksson, Lua; Aronson, Melyssa; Clarke, Blaise; Mojtahedi, Golnessa; Massey, Christine; Oza, Amit M; Gallinger, Steven; Pollett, Aaron; Mackay, Helen; Bernardini, Marcus Q; Ferguson, Sarah E

    2015-02-01

    The brief Family History Questionnaire (bFHQ) was developed to identify endometrial cancer patients whose family histories suggest Lynch syndrome (LS). We compared the bFHQ, extended Family History Questionnaire (eFHQ) and dictated medical records (DMRs) to determine which family history screening strategy is superior in identifying LS in unselected women with newly diagnosed endometrial cancer that have undergone universal germline testing. Prospective cohort study recruited women with newly diagnosed endometrial cancer to evaluate screening strategies to identify LS. Participants completed bFHQ and eFHQ, had tumor assessed with immunohistochemistry (IHC) for mismatch repair proteins (MMR) and micro-satellite instability testing and underwent universal germline testing for LS. The sensitivity, specificity, positive and negative predictive values (PPV, NPV) were compared between the family history screening strategies as well as IHC. 118 of 182 eligible patients (65%) consented; 87 patients (74%) were evaluable with both family history and germline mutation status. Median age was 61years (range 26-91). All 7 patients with confirmed LS were correctly identified by bFHQ, compared to 5 and 4 by eFHQ and DMR, respectively. The sensitivity, specificity, PPV and NPV values of bFHQ were 100%, 76.5%, 25.9% and 100%, respectively, performing similar to IHC testing. While eFHQ was more specific than bFHQ (86.7% vs. 76.5%, P=0.007), 2 cases of LS were missed. The patient-administered bFHQ effectively identified women with confirmed LS and is a good screening tool to triage women with endometrial cancer for further genetic assessment. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Genomic tests for ovarian cancer detection and management.

    PubMed

    Myers, Evan R; Havrilesky, Laura J; Kulasingam, Shalini L; Sanders, Gillian D; Cline, Kathryn E; Gray, Rebecca N; Berchuck, Andrew; McCrory, Douglas C

    2006-10-01

    To assess the evidence that the use of genomic tests for ovarian cancer screening, diagnosis, and treatment leads to improved outcomes. PubMed and reference lists of recent reviews. We evaluated tests for: (a) single gene products; (b) genetic variations affecting risk of ovarian cancer; (c) gene expression; and (d) proteomics. For tests covered in recent evidence reports (cancer antigen 125 [CA-125] and breast cancer genes 1 and 2 [BRCA1/2]), we added studies published subsequent to the reports. We sought evidence on: (a) the analytic performance of tests in clinical laboratories; (b) the sensitivity and specificity of tests in different patient populations; (c) the clinical impact of testing in asymptomatic women, women with suspected ovarian cancer, and women with diagnosed ovarian cancer; (d) the harms of genomic testing; and (e) the impact of direct-to-consumer and direct-to-physician advertising on appropriate use of tests. We also constructed a computer simulation model to test the impact of different assumptions about ovarian cancer natural history on the relative effectiveness of different strategies. There are reasonable data on the clinical laboratory performance of most radioimmunoassays, but the majority of the data on other genomic tests comes from research laboratories. Genomic test sensitivity/specificity estimates are limited by small sample sizes, spectrum bias, and unrealistically large prevalences of ovarian cancer; in particular, estimates of positive predictive values derived from most of the studies are substantially higher than would be expected in most screening or diagnostic settings. We found no evidence relevant to the question of the impact of genomic tests on health outcomes in asymptomatic women. Although there is a relatively large literature on the association of test results and various clinical outcomes, the clinical utility of changing management based on these results has not been evaluated. We found no evidence that genomic tests for ovarian cancer have unique harms beyond those common to other tests for genetic susceptibility or other tests used in screening, diagnosis, and management of ovarian cancer. Studies of a direct-to-consumer campaign for BRCA1/2 testing suggest increased utilization, but the effect on "appropriateness" was unclear. Model simulations suggest that annual screening, even with a highly sensitive test, will not reduce ovarian cancer mortality by more than 50 percent; frequent screening has a very low positive predictive value, even with a highly specific test. Although research remains promising, adaptation of genomic tests into clinical practice must await appropriately designed and powered studies in relevant clinical settings.

  1. Keeping Your Compressor Healthy: Developing the Right Lubricant Formulation is the Key

    NASA Astrophysics Data System (ADS)

    Karnaz, Joseph A.; Kultgen, Derek W.

    2015-08-01

    Selecting the correct compressor lubricant is crucial to the duration of the compressor and the refrigerant systems’ useful life. However, developing an optimized lubricant for a refrigeration system requires a multitude of screenings and tests. The compatibility and stability of the lubricant with the refrigerant and compressor components needs to be examined at various accelerated conditions. The lubricant and refrigerant working viscosity must be determined at various refrigerant concentrations, temperatures and pressures as the diluted refrigerant in the lubricant has a significant effect on the viscosity. The correct lubricant formulation needs to be investigated for optimal performance. A compressor lubricant can provide many benefits to a refrigeration system such as bearing durability, sealing, and increased efficiency. Sometimes it is necessary to formulate the lubricant in order to optimize system performance. Specifically, this study investigated anti-wear properties of different oil additives to create a more robust refrigeration system. Many different additives and concentrations were considered and screened. Pending a successful screen test; these different additives’ anti-wear properties were analyzed using bench top tribology tests. To reduce uncertainty and provide more in-situ results the different additives were operated in a refrigerant compressor on a gas-loop testing apparatus. Oil samples were taken periodically during the test duration for analysis. Lastly, upon test completion the compressors were dismantled and the parts were examined to determine the effectiveness of the anti-wear additives.

  2. Canadian Public Health Laboratory Network laboratory guidelines for congenital syphilis and syphilis screening in pregnant women in Canada.

    PubMed

    Singh, Ameeta E; Levett, Paul N; Fonseca, Kevin; Jayaraman, Gayatri C; Lee, Bonita E

    2015-01-01

    Despite universal access to screening for syphilis in all pregnant women in Canada, cases of congenital syphilis have been reported in recent years in areas experiencing a resurgence of infectious syphilis in heterosexual partnerships. Antenatal screening in the first trimester continues to be important and should be repeated at 28 to 32 weeks and again at delivery in women at high risk of acquiring syphilis. The diagnosis of congenital syphilis is complex and is based on a combination of maternal history and clinical and laboratory criteria in both mother and infant. Serologic tests for syphilis remain important in the diagnosis of congenital syphilis and are complicated by the passive transfer of maternal antibodies which can affect the interpretation of reactive serologic tests in the infant. All infants born to mothers with reactive syphilis tests should have nontreponemal tests (NTT) and treponemal tests (TT) performed in parallel with the mother's tests. A fourfold or higher titre in the NTT in the infant at delivery is strongly suggestive of congenital infection but the absence of a fourfold or greater NTT titre does not exclude congenital infection. IgM tests for syphilis are not currently available in Canada and are not recommended due to poor performance. Other evaluation in the newborn infant may include long bone radiographs and cerebrospinal fluid tests but all suspect cases should be managed in conjunction with sexually transmitted infection and/or pediatric experts.

  3. Canadian Public Health Laboratory Network laboratory guidelines for congenital syphilis and syphilis screening in pregnant women in Canada

    PubMed Central

    Singh, Ameeta E; Levett, Paul N; Fonseca, Kevin; Jayaraman, Gayatri C; Lee, Bonita E

    2015-01-01

    Despite universal access to screening for syphilis in all pregnant women in Canada, cases of congenital syphilis have been reported in recent years in areas experiencing a resurgence of infectious syphilis in heterosexual partnerships. Antenatal screening in the first trimester continues to be important and should be repeated at 28 to 32 weeks and again at delivery in women at high risk of acquiring syphilis. The diagnosis of congenital syphilis is complex and is based on a combination of maternal history and clinical and laboratory criteria in both mother and infant. Serologic tests for syphilis remain important in the diagnosis of congenital syphilis and are complicated by the passive transfer of maternal antibodies which can affect the interpretation of reactive serologic tests in the infant. All infants born to mothers with reactive syphilis tests should have nontreponemal tests (NTT) and treponemal tests (TT) performed in parallel with the mother’s tests. A fourfold or higher titre in the NTT in the infant at delivery is strongly suggestive of congenital infection but the absence of a fourfold or greater NTT titre does not exclude congenital infection. IgM tests for syphilis are not currently available in Canada and are not recommended due to poor performance. Other evaluation in the newborn infant may include long bone radiographs and cerebrospinal fluid tests but all suspect cases should be managed in conjunction with sexually transmitted infection and/or pediatric experts. PMID:25798162

  4. First-trimester screening for chromosomal abnormalities: advantages of an instant results approach.

    PubMed

    Norton, Mary E

    2010-09-01

    Protocols that include first trimester screening for fetal chromosome abnormalities have become standard of care throughout the United States. Earlier screening allows for first trimester diagnostic testing in cases found to be at increased risk. However, first trimester screening requires coordination of the nuchal translucency ultrasound screening (NT) and biochemical screening, during early, specific, narrow, but slightly different gestational age ranges. Instant results can often be provided at the time of the NT ultrasound if preceded by the programs that perform the biochemical analyses; this optimizes the benefits of the first trimester approach while improving efficiency and communication with the patient. This article discusses the benefits and logistics of such an approach. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Comparative effectiveness of incorporating a hypothetical DCIS prognostic marker into breast cancer screening.

    PubMed

    Trentham-Dietz, Amy; Ergun, Mehmet Ali; Alagoz, Oguzhan; Stout, Natasha K; Gangnon, Ronald E; Hampton, John M; Dittus, Kim; James, Ted A; Vacek, Pamela M; Herschorn, Sally D; Burnside, Elizabeth S; Tosteson, Anna N A; Weaver, Donald L; Sprague, Brian L

    2018-02-01

    Due to limitations in the ability to identify non-progressive disease, ductal carcinoma in situ (DCIS) is usually managed similarly to localized invasive breast cancer. We used simulation modeling to evaluate the potential impact of a hypothetical test that identifies non-progressive DCIS. A discrete-event model simulated a cohort of U.S. women undergoing digital screening mammography. All women diagnosed with DCIS underwent the hypothetical DCIS prognostic test. Women with test results indicating progressive DCIS received standard breast cancer treatment and a decrement to quality of life corresponding to the treatment. If the DCIS test indicated non-progressive DCIS, no treatment was received and women continued routine annual surveillance mammography. A range of test performance characteristics and prevalence of non-progressive disease were simulated. Analysis compared discounted quality-adjusted life years (QALYs) and costs for test scenarios to base-case scenarios without the test. Compared to the base case, a perfect prognostic test resulted in a 40% decrease in treatment costs, from $13,321 to $8005 USD per DCIS case. A perfect test produced 0.04 additional QALYs (16 days) for women diagnosed with DCIS, added to the base case of 5.88 QALYs per DCIS case. The results were sensitive to the performance characteristics of the prognostic test, the proportion of DCIS cases that were non-progressive in the model, and the frequency of mammography screening in the population. A prognostic test that identifies non-progressive DCIS would substantially reduce treatment costs but result in only modest improvements in quality of life when averaged over all DCIS cases.

  6. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    PubMed

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  7. Central auditory processing disorder (CAPD) tests in a school-age hearing screening programme - analysis of 76,429 children.

    PubMed

    Skarzynski, Piotr H; Wlodarczyk, Andrzej W; Kochanek, Krzysztof; Pilka, Adam; Jedrzejczak, Wiktor W; Olszewski, Lukasz; Bruski, Lukasz; Niedzielski, Artur; Skarzynski, Henryk

    2015-01-01

    Hearing disorders among school-age children are a current concern. Continuing studies have been performed in Poland since 2008, and on 2 December 2011 the EU Council adopted Conclusions on the Early Detection and Treatment of Communication Disorders in Children, Including the Use of e-Health Tools and innovative Solutions. The discussion now focuses not only on the efficacy of hearing screening programmes in schoolchildren, but what should be its general aim and what tests it should include? This paper makes the case that it is important to include central auditory processing disorder (CAPD) tests. One such test is the dichotic digits test (DDT). The aim of the presented study was to evaluate the usefulness of the DDT in detecting central hearing disorders in school-age children. During hearing screening programmes conducted in Poland in 2008-2010, exactly 235,664 children (7-12-years-old) were screened in 9,325 schools. Of this number, 7,642 were examined using the DDT test for CAPD. Screening programmes were conducted using the Sense Examination Platform. With the cut-off criterion set at the 5th percentile, results for the DDT applied in a divided attention mode were 11.4% positive for 7-year-olds and 11.3% for 12-year-olds. In the focused attention mode, the comparable result for 12-year-olds was 9.7%. There was a clear right ear advantage. In children with positive DDT results, a higher incidence of other disorders, such as dyslexia, was observed. A test for CAPD should be included in the hearing screening of school-age children. The results of this study form the basis for developing Polish standards in this area.

  8. Sequential Objective Structured Clinical Examination based on item response theory in Iran.

    PubMed

    Hejri, Sara Mortaz; Jalili, Mohammad

    2017-01-01

    In a sequential objective structured clinical examination (OSCE), all students initially take a short screening OSCE. Examinees who pass are excused from further testing, but an additional OSCE is administered to the remaining examinees. Previous investigations of sequential OSCE were based on classical test theory. We aimed to design and evaluate screening OSCEs based on item response theory (IRT). We carried out a retrospective observational study. At each station of a 10-station OSCE, the students' performance was graded on a Likert-type scale. Since the data were polytomous, the difficulty parameters, discrimination parameters, and students' ability were calculated using a graded response model. To design several screening OSCEs, we identified the 5 most difficult stations and the 5 most discriminative ones. For each test, 5, 4, or 3 stations were selected. Normal and stringent cut-scores were defined for each test. We compared the results of each of the 12 screening OSCEs to the main OSCE and calculated the positive and negative predictive values (PPV and NPV), as well as the exam cost. A total of 253 students (95.1%) passed the main OSCE, while 72.6% to 94.4% of examinees passed the screening tests. The PPV values ranged from 0.98 to 1.00, and the NPV values ranged from 0.18 to 0.59. Two tests effectively predicted the results of the main exam, resulting in financial savings of 34% to 40%. If stations with the highest IRT-based discrimination values and stringent cut-scores are utilized in the screening test, sequential OSCE can be an efficient and convenient way to conduct an OSCE.

  9. Evaluation of an enhanced gravity-based fine-coal circuit for high-sulfur coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohanty, M.K.; Samal, A.R.; Palit, A.

    One of the main objectives of this study was to evaluate a fine-coal cleaning circuit using an enhanced gravity separator specifically for a high sulfur coal application. The evaluation not only included testing of individual unit operations used for fine-coal classification, cleaning and dewatering, but also included testing of the complete circuit simultaneously. At a scale of nearly 2 t/h, two alternative circuits were evaluated to clean a minus 0.6-mm coal stream utilizing a 150-mm-diameter classifying cyclone, a linear screen having a projected surface area of 0.5 m{sup 2}, an enhanced gravity separator having a bowl diameter of 250 mmmore » and a screen-bowl centrifuge having a bowl diameter of 500 mm. The cleaning and dewatering components of both circuits were the same; however, one circuit used a classifying cyclone whereas the other used a linear screen as the classification device. An industrial size coal spiral was used to clean the 2- x 0.6-mm coal size fraction for each circuit to estimate the performance of a complete fine-coal circuit cleaning a minus 2-mm particle size coal stream. The 'linear screen + enhanced gravity separator + screen-bowl circuit' provided superior sulfur and ash-cleaning performance to the alternative circuit that used a classifying cyclone in place of the linear screen. Based on these test data, it was estimated that the use of the recommended circuit to treat 50 t/h of minus 2-mm size coal having feed ash and sulfur contents of 33.9% and 3.28%, respectively, may produce nearly 28.3 t/h of clean coal with product ash and sulfur contents of 9.15% and 1.61 %, respectively.« less

  10. Performance of the EUCAST Disk Diffusion Method, the CLSI Agar Screen Method, and the Vitek 2 Automated Antimicrobial Susceptibility Testing System for Detection of Clinical Isolates of Enterococci with Low- and Medium-Level VanB-Type Vancomycin Resistance: a Multicenter Study

    PubMed Central

    Giske, Christian G.; Haldorsen, Bjørg; Matuschek, Erika; Schønning, Kristian; Leegaard, Truls M.; Kahlmeter, Gunnar

    2014-01-01

    Different antimicrobial susceptibility testing methods to detect low-level vancomycin resistance in enterococci were evaluated in a Scandinavian multicenter study (n = 28). A phenotypically and genotypically well-characterized diverse collection of Enterococcus faecalis (n = 12) and Enterococcus faecium (n = 18) strains with and without nonsusceptibility to vancomycin was examined blindly in Danish (n = 5), Norwegian (n = 13), and Swedish (n = 10) laboratories using the EUCAST disk diffusion method (n = 28) and the CLSI agar screen (n = 18) or the Vitek 2 system (bioMérieux) (n = 5). The EUCAST disk diffusion method (very major error [VME] rate, 7.0%; sensitivity, 0.93; major error [ME] rate, 2.4%; specificity, 0.98) and CLSI agar screen (VME rate, 6.6%; sensitivity, 0.93; ME rate, 5.6%; specificity, 0.94) performed significantly better (P = 0.02) than the Vitek 2 system (VME rate, 13%; sensitivity, 0.87; ME rate, 0%; specificity, 1). The performance of the EUCAST disk diffusion method was challenged by differences in vancomycin inhibition zone sizes as well as the experience of the personnel in interpreting fuzzy zone edges as an indication of vancomycin resistance. Laboratories using Oxoid agar (P < 0.0001) or Merck Mueller-Hinton (MH) agar (P = 0.027) for the disk diffusion assay performed significantly better than did laboratories using BBL MH II medium. Laboratories using Difco brain heart infusion (BHI) agar for the CLSI agar screen performed significantly better (P = 0.017) than did those using Oxoid BHI agar. In conclusion, both the EUCAST disk diffusion and CLSI agar screening methods performed acceptably (sensitivity, 0.93; specificity, 0.94 to 0.98) in the detection of VanB-type vancomycin-resistant enterococci with low-level resistance. Importantly, use of the CLSI agar screen requires careful monitoring of the vancomycin concentration in the plates. Moreover, disk diffusion methodology requires that personnel be trained in interpreting zone edges. PMID:24599985

  11. New solutions to the constant-head test performed at a partially penetrating well

    NASA Astrophysics Data System (ADS)

    Chang, Y. C.; Yeh, H. D.

    2009-05-01

    SummaryThe mathematical model describing the aquifer response to a constant-head test performed at a fully penetrating well can be easily solved by the conventional integral transform technique. In addition, the Dirichlet-type condition should be chosen as the boundary condition along the rim of wellbore for such a test well. However, the boundary condition for a test well with partial penetration must be considered as a mixed-type condition. Generally, the Dirichlet condition is prescribed along the well screen and the Neumann type no-flow condition is specified over the unscreened part of the test well. The model for such a mixed boundary problem in a confined aquifer system of infinite radial extent and finite vertical extent is solved by the dual series equations and perturbation method. This approach provides analytical results for the drawdown in the partially penetrating well and the well discharge along the screen. The semi-analytical solutions are particularly useful for the practical applications from the computational point of view.

  12. Screening for hypopituitarism in 509 patients with traumatic brain injury or subarachnoid hemorrhage.

    PubMed

    Kopczak, Anna; Kilimann, Ingo; von Rosen, Friedrich; Krewer, Carmen; Schneider, Harald Jörn; Stalla, Günter Karl; Schneider, Manfred

    2014-01-01

    We performed a screening on patients with traumatic brain injury (TBI) or subarachnoid hemorrhage (SAH) to determine the prevalence of post-traumatic hypopituitarism in neurorehabilitation in a cross-sectional, observational single-center study. In addition, the therapeutic consequences of our screening were analyzed retrospectively. From February 2006 to August 2009, patients between 18 and 65 years (n=509) with the diagnosis of TBI (n=340) or SAH (n=169) were screened within two weeks of admittance to neurorehabilitation as clinical routine. Blood was drawn to determine fasting cortisol, free thyroxine (fT4), prolactin, testosterone or estradiol, and insulin-like growth factor I (IGF-I). Patients with abnormalities in the screening or clinical signs of hypopituitarism received further stimulation tests: growth hormone releasing hormone -L-arginine-test and adrenocorticotrophic hormone (ACTH)-test (n=36); ACTH-test alone (n=26); or insulin tolerance test (n=56). In our screening of 509 patients, 28.5% showed lowered values in at least one hormone of the hypothalamus-pituitary axis and 4.5% in two or more axes. The most common disturbance was a decrease of testosterone in 40.7% of all men (in the following 13/131 men were given substitution therapy). Low fT4 was detected in 5.9% (n=3 were given substitution therapy). Low IGF-I was detected in 5.8%, low cortisol in 1.4%, and low prolactin in 0.2%; none were given substitution therapy. Further stimulation tests revealed growth hormone deficiency in 20.7% (n=19/92) and hypocortisolism in 23.7% (n=28/118). Laboratory values possibly indicating hypopituitarism (33%) were common but did not always implicate post-traumatic hypopituitarism. Laboratory values possibly indicating hypopituitarism were common in our screening but most patients were clinically not diagnosed as pituitary insufficient and did not receive hormone replacement therapy. A routine screening of all patients in neurorehabilitation without considering the time since injury, the severity of illness and therapeutic consequences seems not useful.

  13. Performance on the Functional Movement Screen Is Related to Hop Performance But Not to Hip and Knee Strength in Collegiate Football Players.

    PubMed

    Willigenburg, Nienke; Hewett, Timothy E

    2017-03-01

    To define the relationship between Functional Movement Screen (FMS) scores and hop performance, hip strength, and knee strength in collegiate football players. Cross-sectional cohort. Freshmen of a Division I collegiate American football team (n = 59). The athletes performed the FMS, and also a variety of hop tests, isokinetic knee strength, and isometric hip strength tasks. We recorded total FMS score, peak strength, and hop performance, and we calculated asymmetries between legs on the different tasks. Spearman correlation coefficients quantified the relationships between these measures, and χ analyses compared the number of athletes with asymmetries on the different tasks. We observed significant correlations (r = 0.38-0.56, P ≤ 0.02) between FMS scores and hop distance but not between FMS scores and hip or knee strength (all P ≥ 0.21). The amount of asymmetry on the FMS test was significantly correlated to the amount of asymmetry on the timed 6-m hop (r = 0.44, P < 0.01) but not to hip or knee strength asymmetries between limbs (all P ≥ 0.34). Functional Movement Screen score was positively correlated to hop distance, and limb asymmetry in FMS tasks was correlated to limb asymmetry in 6-m hop time in football players. No significant correlations were observed between FMS score and hip and knee strength or between FMS asymmetry and asymmetries in hip and knee strength between limbs. These results indicate that a simple hop for distance test may be a time-efficient and cost-efficient alternative to FMS testing in athletes and that functional asymmetries between limbs do not coincide with strength asymmetries.

  14. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  15. Recipient screening in IVF: first data from women undergoing anonymous oocyte donation in Dublin.

    PubMed

    Walsh, Anthony P H; Omar, Ahmed B; Marron, Kevin D; Walsh, David J; Salma, Umme; Sills, E Scott

    2011-04-20

    Guidelines for safe gamete donation have emphasised donor screening, although none exist specifically for testing oocyte recipients. Pre-treatment assessment of anonymous donor oocyte IVF treatment in Ireland must comply with the European Union Tissues and Cells Directive (Directive 2004/23/EC). To determine the effectiveness of this Directive when applied to anonymous oocyte recipients in IVF, we reviewed data derived from selected screening tests performed in this clinical setting. Data from tests conducted at baseline for all women enrolling as recipients (n = 225) in the anonymous oocyte donor IVF programme at an urban IVF referral centre during a 24-month period were analysed. Patient age at programme entry and clinical pregnancy rate were also tabulated. All recipients had at least one prior negative test for HIV, Hepatitis B/C, chlamydia, gonorrhoea and syphilis performed by her GP or other primary care provider before reproductive endocrinology consultation. Mean (±SD) age for donor egg IVF recipients was 40.7 ± 4.2 yrs. No baseline positive chlamydia, gonorrhoea or syphilis screening results were identified among recipients for anonymous oocyte donation IVF during the assessment interval. Mean pregnancy rate (per embryo transfer) in this group was 50.5%. When tests for HIV, Hepatitis B/C, chlamydia, gonorrhoea and syphilis already have been confirmed to be negative before starting the anonymous donor oocyte IVF sequence, additional (repeat) testing on the recipient contributes no new clinical information that would influence treatment in this setting. Patient safety does not appear to be enhanced by application of Directive 2004/23/EC to recipients of anonymous donor oocyte IVF treatment. Given the absence of evidence to quantify risk, this practice is difficult to justify when applied to this low-risk population.

  16. CDC Screening Recommendation for Baby Boomers and Hepatitis C Virus Testing in the US Military Health System.

    PubMed

    Manjelievskaia, Janna; Brown, Derek; Shriver, Craig D; Zhu, Kangmin

    Chronic hepatitis C virus (HCV) is the most common blood-borne infection in the United States, with an estimated 2.7 to 3.9 million cases as of 2014. In August 2012, the Centers for Disease Control and Prevention (CDC) recommended 1-time HCV testing of all baby boomers. The objectives of this study were to (1) determine the proportion of people screened for HCV in the US Department of Defense Military Health System before and after the CDC screening recommendation for baby boomers and (2) assess whether certain patient or system factors were associated with screening for HCV before and after August 2012. We used a dataset containing 5% of beneficiaries randomly selected from the Military Health System Data Repository medical claims database for the period July 2011 through September 2013. Of 108 223 people eligible for HCV screening during the first period (July 2011 through July 2012), 1812 (1.7%) were screened. Of 109 768 people eligible during the second period (September 2012 through September 2013), 2599 (2.4%) were screened. HCV screening receipt was related to benefit type (Prime before August 2012: adjusted odds ratio [aOR] = 2.16; 95% confidence interval [CI], 1.89-2.46; Prime after August 2012: aOR = 1.93; 95% CI, 1.73-2.16) and care source (direct care before August 2012: aOR = 1.80; 95% CI, 1.57-2.07; direct care after August 2012: aOR = 2.45; 95% CI, 2.18-2.75); male sex (aOR = 1.17; 95% CI, 1.06-1.29) and black race (aOR = 1.20; 95% CI, 1.05-1.37) were associated with HCV testing only before August 2012. Interventions should be implemented to increase awareness and knowledge of the current national HCV testing recommendation among baby boomers to seek out testing and health care providers to perform screening.

  17. Screening for fetal growth restriction using fetal biometry combined with maternal biomarkers.

    PubMed

    Gaccioli, Francesca; Aye, Irving L M H; Sovio, Ulla; Charnock-Jones, D Stephen; Smith, Gordon C S

    2018-02-01

    Fetal growth restriction is a major determinant of perinatal morbidity and mortality. Screening for fetal growth restriction is a key element of prenatal care but it is recognized to be problematic. Screening using clinical risk assessment and targeting ultrasound to high-risk women is the standard of care in the United States and United Kingdom, but the approach is known to have low sensitivity. Systematic reviews of randomized controlled trials do not demonstrate any benefit from universal ultrasound screening for fetal growth restriction in the third trimester, but the evidence base is not strong. Implementation of universal ultrasound screening in low-risk women in France failed to reduce the risk of complications among small-for-gestational-age infants but did appear to cause iatrogenic harm to false positives. One strategy to making progress is to improve screening by developing more sensitive and specific tests with the key goal of differentiating between healthy small fetuses and those that are small through fetal growth restriction. As abnormal placentation is thought to be the major cause of fetal growth restriction, one approach is to combine fetal biometry with an indicator of placental dysfunction. In the past, these indicators were generally ultrasonic measurements, such as Doppler flow velocimetry of the uteroplacental circulation. However, another promising approach is to combine ultrasonic suspicion of small-for-gestational-age infant with a blood test indicating placental dysfunction. Thus far, much of the research on maternal serum biomarkers for fetal growth restriction has involved the secondary analysis of tests performed for other indications, such as fetal aneuploidies. An exemplar of this is pregnancy-associated plasma protein A. This blood test is performed primarily to assess the risk of Down syndrome, but women with low first-trimester levels are now serially scanned in later pregnancy due to associations with placental causes of stillbirth, including fetal growth restriction. The development of "omic" technologies presents a huge opportunity to identify novel biomarkers for fetal growth restriction. The hope is that when such markers are measured alongside ultrasonic fetal biometry, the combination would have strong predictive power for fetal growth restriction and its related complications. However, a series of important methodological considerations in assessing the diagnostic effectiveness of new tests will have to be addressed. The challenge thereafter will be to identify novel disease-modifying interventions, which are the essential partner to an effective screening test to achieve clinically effective population-based screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. The Influence of Juggling on Mental Rotation Performance in Children

    ERIC Educational Resources Information Center

    Jansen, Petra; Lange, Leonie F.; Heil, Martin

    2011-01-01

    Study aim: To assess the influence of juggling training on mental rotation performance in children. Material and methods: Two groups of girls aged 6-14 years were studied: experimental (EG; n = 26) and control (CG; n = 24). All girls solved a mental rotation task with 3-D block figures on computer screen (pre-test). After the initial test, EG…

  19. Intensification of the Learning Process: Gross Motor Performance Scale. A Series of Reports Designed for Classroom Use.

    ERIC Educational Resources Information Center

    Bucks County Public Schools, Doylestown, PA.

    The Gross Motor Performance Screening Test was designed to aid the classroom teacher in obtaining specific information about the child's physical abilities. The test includes items which have been found to measure the various factors of physical fitness. It also includes items to measure skills important to the child and adult. Included also are…

  20. Circulating microRNA signature as liquid-biopsy to monitor lung cancer in low-dose computed tomography screening.

    PubMed

    Sestini, Stefano; Boeri, Mattia; Marchiano, Alfonso; Pelosi, Giuseppe; Galeone, Carlotta; Verri, Carla; Suatoni, Paola; Sverzellati, Nicola; La Vecchia, Carlo; Sozzi, Gabriella; Pastorino, Ugo

    2015-10-20

    Liquid biopsies can detect biomarkers carrying information on the development and progression of cancer. We demonstrated that a 24 plasma-based microRNA signature classifier (MSC) was capable of increasing the specificity of low dose computed tomography (LDCT) in a lung cancer screening trial. In the present study, we tested the prognostic performance of MSC, and its ability to monitor disease status recurrence in LDCT screening-detected lung cancers.Between 2000 and 2010, 3411 heavy smokers enrolled in two screening programmes, underwent annual or biennial LDCT. During the first five years of screening, 84 lung cancer patients were classified according to one of the three MSC levels of risk: high, intermediate or low. Kaplan-Meier survival analysis was performed according to MSC and clinico-pathological information. Follow-up MSC analysis was performed on longitudinal plasma samples (n = 100) collected from 31 patients before and after surgical resection.Five-year survival was 88.9% for low risk, 79.5% for intermediate risk and 40.1% for high risk MSC (p = 0.001). The prognostic power of MSC persisted after adjusting for tumor stage (p = 0.02) and when the analysis was restricted to LDCT-detected cases after exclusion of interval cancers (p < 0.001). The MSC risk level decreased after surgery in 76% of the 25 high-intermediate subjects who remained disease free, whereas in relapsing patients an increase of the MSC risk level was observed at the time of detection of second primary tumor or metastatic progression.These results encourage exploiting the MSC test for lung cancer monitoring in LDCT screening for lung cancer.

  1. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  2. [Validity criteria of a short test to assess speech and language competence in 4-year-olds].

    PubMed

    Euler, H A; Holler-Zittlau, I; Minnen, S; Sick, U; Dux, W; Zaretsky, Y; Neumann, K

    2010-11-01

    A psychometrically constructed short test as a prerequisite for screening was developed on the basis of a revision of the Marburger Speech Screening to assess speech/language competence among children in Hessen (Germany). A total of 257 children (age 4.0 to 4.5 years) performed the test battery for speech/language competence; 214 children repeated the test 1 year later. Test scores correlated highly with scores of two competing language screenings (SSV, HASE) and with a combined score from four diagnostic tests of individual speech/language competences (Reynell III, patholinguistic diagnostics in impaired language development, PLAKSS, AWST-R). Validity was demonstrated by three comparisons: (1) Children with German family language had higher scores than children with another language. (2) The 3-month-older children achieved higher scores than younger children. (3) The difference between the children with German family language and those with another language was higher for the 3-month-older than for the younger children. The short test assesses the speech/language competence of 4-year-olds quickly, validly, and comprehensively.

  3. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    PubMed

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  4. Effects of telephone follow-up on blood glucose levels and postpartum screening in mothers with Gestational Diabetes Mellitus.

    PubMed

    Khorshidi Roozbahani, Rezvan; Geranmayeh, Mehrnaz; Hantoushzadeh, Sedigheh; Mehran, Abbas

    2015-01-01

    Gestational diabetes mellitus (GDM) is a form of diabetes that occurs in pregnancy. GDM, defined as glucose intolerance, first diagnosed or initiated during pregnancy affects 1-14% of pregnancies based on various studies. Screening and early diagnosis and appropriate glycemic control can improve prenatal outcomes. Telephone follow-up seems to be a reasonable way for pregnant women follow-up. The present study evaluated the effects of telephone follow-up on blood glucose level during pregnancy and postpartum screening. Eighty mothers with GDM were enrolled in this clinical trial and randomly divided into intervention and control groups. All mothers were asked to check their blood sugar levels fivetimes daily. In intervention group, telephone intervention was performed for 10 weeks. In each follow-up, individuals were followed for insulin injections, diet, clinical tests and reminding the next visit. In control group, three times of telephone call was established to record blood sugar levels. Another telephone call was established at 6 weeks of postpartum in both study groups to evaluate the performance of the screening test for blood sugar. The mean age of mothers was 30.9±5 years in the control and 30.7±5.1 years in the intervention groups In intervention group, mean level of blood glucose, 2 hours after lunch at 28 weeks of pregnancy was significantly lower than the control group (P<0.05). Mean differences in levels of fasting blood glucose between 28 weeks and 32 and between 28 and 36 weeks of pregnancy were significantly higher in the intervention than the control group (P<0.05). Rate of postpartum glucose screening test was significantly higher in the intervention group (P<0.001). The findings of this study demonstrated that telephone follow-up could significantly reduce fasting blood glucose levels in mothers with gestational diabetes and also increased the rate of postpartum screening test.

  5. Pooled analysis of the accuracy of five cervical cancer screening tests assessed in eleven studies in Africa and India.

    PubMed

    Arbyn, Marc; Sankaranarayanan, Rengaswamy; Muwonge, Richard; Keita, Namory; Dolo, Amadou; Mbalawa, Charles Gombe; Nouhou, Hassan; Sakande, Boblewende; Wesley, Ramani; Somanathan, Thara; Sharma, Anjali; Shastri, Surendra; Basu, Parthasarathy

    2008-07-01

    Cervical cancer is the main cancer among women in sub-Saharan Africa, India and other parts of the developing world. Evaluation of screening performance of effective, feasible and affordable early detection and management methods is a public health priority. Five screening methods, naked eye visual inspection of the cervix uteri after application of diluted acetic acid (VIA), or Lugol's iodine (VILI) or with a magnifying device (VIAM), the Pap smear and human papillomavirus testing with the high-risk probe of the Hybrid Capture-2 assay (HC2), were evaluated in 11 studies in India and Africa. More than 58,000 women, aged 25-64 years, were tested with 2-5 screening tests and outcome verification was done on all women independent of the screen test results. The outcome was presence or absence of cervical intraepithelial neoplasia (CIN) of different degrees or invasive cervical cancer. Verification was based on colposcopy and histological interpretation of colposcopy-directed biopsies. Negative colposcopy was accepted as a truly negative outcome. VIA showed a sensitivity of 79% (95% CI 73-85%) and 83% (95% CI 77-89%), and a specificity of 85% (95% CI 81-89%) and 84% (95% CI 80-88%) for the outcomes CIN2+ or CIN3+, respectively. VILI was on average 10% more sensitive and equally specific. VIAM showed similar results as VIA. The Pap smear showed lowest sensitivity, even at the lowest cutoff of atypical squamous cells of undetermined significance (57%; 95% CI 38-76%) for CIN2+ but the specificity was rather high (93%; 95% CI 89-97%). The HC2-assay showed a sensitivity for CIN2+ of 62% (95% CI 56-68%) and a specificity of 94% (95% CI 92-95%). Substantial interstudy variation was observed in the accuracy of the visual screening methods. Accuracy of visual methods and cytology increased over time, whereas performance of HC2 was constant. Results of visual tests and colposcopy were highly correlated. This study was the largest ever done that evaluates the cross-sectional accuracy of screening tests for cervical cancer precursors in developing countries. The merit of the study was that all screened subjects were submitted to confirmatory investigations avoiding to verification bias. A major finding was the consistently higher sensitivity but equal specificity of VILI compared with VIA. Nevertheless, some caution is warranted in the interpretation of observed accuracy measures, since a certain degree of gold standard misclassification cannot be excluded. Because of the correlation between visual screening tests and colposcopy and a certain degree of over-diagnosis of apparent CIN2+ by study pathologists, it is possible that both sensitivity and specificity of VIA and VILI were overestimated. Gold standard verification error could also explain the surprisingly low sensitivity of HC2, which contrasts with findings from other studies. (c) 2008 Wiley-Liss, Inc.

  6. Core compressor exit stage study. Volume 3: Data and performance report for screening test configurations

    NASA Technical Reports Server (NTRS)

    Wisler, D. C.

    1980-01-01

    Rear stage blading designs that have lower losses in their endwall boundary layer regions were developed. Test data and performance results for rotor B, stator B, and stator C - blading designs that offer promise of reducing endwall losses relative to the baseline are given. A low speed research compressor was the principal investigative tool. The tests were conducted using four identical stages of blading so that the test data would be obtained in a true multistage environment.

  7. Some performance effects of age and low blood alcohol levels on a computerized neuropsychological test.

    DOT National Transportation Integrated Search

    1995-02-01

    COGSCREEN is a computerized test battery developed for the Federal Aviation Administration as an airman neuropsychological screening instrument for cognitive functioning. This study explored a multifaceted application of the sensitivity of the batter...

  8. Academic Performance and Lifestyle Behaviors in Australian School Children: A Cluster Analysis.

    PubMed

    Dumuid, Dorothea; Olds, Timothy; Martín-Fernández, Josep-Antoni; Lewis, Lucy K; Cassidy, Leah; Maher, Carol

    2017-12-01

    Poor academic performance has been linked with particular lifestyle behaviors, such as unhealthy diet, short sleep duration, high screen time, and low physical activity. However, little is known about how lifestyle behavior patterns (or combinations of behaviors) contribute to children's academic performance. We aimed to compare academic performance across clusters of children with common lifestyle behavior patterns. We clustered participants (Australian children aged 9-11 years, n = 284) into four mutually exclusive groups of distinct lifestyle behavior patterns, using the following lifestyle behaviors as cluster inputs: light, moderate, and vigorous physical activity; sedentary behavior and sleep, derived from 24-hour accelerometry; self-reported screen time and diet. Differences in academic performance (measured by a nationally administered standardized test) were detected across the clusters, with scores being lowest in the Junk Food Screenies cluster (unhealthy diet/high screen time) and highest in the Sitters cluster (high nonscreen sedentary behavior/low physical activity). These findings suggest that reduction in screen time and an improved diet may contribute positively to academic performance. While children with high nonscreen sedentary time performed better academically in this study, they also accumulated low levels of physical activity. This warrants further investigation, given the known physical and mental benefits of physical activity.

  9. High-throughput fabrication and screening improves gold nanoparticle chemiresistor sensor performance.

    PubMed

    Hubble, Lee J; Cooper, James S; Sosa-Pintos, Andrea; Kiiveri, Harri; Chow, Edith; Webster, Melissa S; Wieczorek, Lech; Raguse, Burkhard

    2015-02-09

    Chemiresistor sensor arrays are a promising technology to replace current laboratory-based analysis instrumentation, with the advantage of facile integration into portable, low-cost devices for in-field use. To increase the performance of chemiresistor sensor arrays a high-throughput fabrication and screening methodology was developed to assess different organothiol-functionalized gold nanoparticle chemiresistors. This high-throughput fabrication and testing methodology was implemented to screen a library consisting of 132 different organothiol compounds as capping agents for functionalized gold nanoparticle chemiresistor sensors. The methodology utilized an automated liquid handling workstation for the in situ functionalization of gold nanoparticle films and subsequent automated analyte testing of sensor arrays using a flow-injection analysis system. To test the methodology we focused on the discrimination and quantitation of benzene, toluene, ethylbenzene, p-xylene, and naphthalene (BTEXN) mixtures in water at low microgram per liter concentration levels. The high-throughput methodology identified a sensor array configuration consisting of a subset of organothiol-functionalized chemiresistors which in combination with random forests analysis was able to predict individual analyte concentrations with overall root-mean-square errors ranging between 8-17 μg/L for mixtures of BTEXN in water at the 100 μg/L concentration. The ability to use a simple sensor array system to quantitate BTEXN mixtures in water at the low μg/L concentration range has direct and significant implications to future environmental monitoring and reporting strategies. In addition, these results demonstrate the advantages of high-throughput screening to improve the performance of gold nanoparticle based chemiresistors for both new and existing applications.

  10. Lower Limb Function in Elderly Korean Adults Is Related to Cognitive Function.

    PubMed

    Kim, A-Sol; Ko, Hae-Jin

    2018-05-01

    Patients with cognitive impairment have decreased lower limb function. Therefore, we aimed to investigate the relationship between lower limb function and cognitive disorders to determine whether lower limb function can be screened to identify cognitive decline. Using Korean National Health Insurance Service-National Sample Cohort database data, we assessed the cognitive and lower limb functioning of 66-year-olds who underwent national health screening between 2010 and 2014. Cognitive function was assessed via a questionnaire. Timed Up-and-Go (TUG) and one-leg-standing (OLS) tests were performed to evaluate lower limb function. Associations between cognitive and lower limb functions were analyzed, and optimal cut-off points for these tests to screen for cognitive decline, were determined. Cognitive function was significantly correlated with TUG interval ( r = 0.414, p < 0.001) and OLS duration ( r = −0.237, p < 0.001). Optimal cut-off points for screening cognitive disorders were >11 s and ≤12 s for TUG interval and OLS duration, respectively. Among 66-year-olds who underwent national health screening, a significant correlation between lower limb and cognitive function was demonstrated. The TUG and OLS tests are useful screening tools for cognitive disorders in elderly patients. A large-scale prospective cohort study should be conducted to investigate the causal relationship between cognitive and lower limb function.

  11. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania.

    PubMed

    Coyle, Catelyn; Kwakwa, Helena

    2016-01-01

    Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012-August 31, 2013) and after (September 1, 2013-May 31, 2014) implementation of the dual-routine HCV/HIV testing model. A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care.

  12. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania

    PubMed Central

    Kwakwa, Helena

    2016-01-01

    Objective Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. Methods National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012–August 31, 2013) and after (September 1, 2013–May 31, 2014) implementation of the dual-routine HCV/HIV testing model. Results A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. Conclusion The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care. PMID:26862229

  13. Incorporating thyroid markers in Down syndrome screening protocols.

    PubMed

    Dhaifalah, Ishraq; Salek, Tomas; Langova, Dagmar; Cuckle, Howard

    2017-05-01

    The article aimed to assess the benefit of incorporating maternal serum thyroid disease marker levels (thyroid-stimulating hormone and free thyroxine) into first trimester Down syndrome screening protocols. Statistical modelling was used to predict performance with and without the thyroid markers. Two protocols were considered: the combined test and the contingent cell-free DNA (cfDNA) test, where 15-40% women are selected for cfDNA because of increased risk based on combined test results. Published parameters were used for the combined test, cfDNA and the Down syndrome means for thyroid-stimulating hormone and free thyroxine; other parameters were derived from a series of 5230 women screened for both thyroid disease and Down syndrome. Combined test: For a fixed 85% detection rate, the predicted false positive rate was reduced from 5.3% to 3.6% with the addition of the thyroid markers. Contingent cfDNA test: For a fixed 95% detection rate, the proportion of women selected for cfDNA was reduced from 25.6% to 20.2%. When screening simultaneously for maternal thyroid disease and Down syndrome, thyroid marker levels should be used in the calculation of Down syndrome risk. The benefit is modest but can be achieved with no additional cost. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  14. The persistence of hepatitis C virus transmission risk in China despite serologic screening of blood donations.

    PubMed

    Wang, Jingxing; Liu, Jing; Huang, Yi; Wright, David J; Li, Julin; Zhou, Zhongmin; He, Weilan; Yang, Tonghan; Yao, Fuzhu; Zhu, Xiangming; Wen, Guoxin; Bi, Xinhong; Tiemuer, Mei-hei-li; Wen, Xiuqiong; Huang, Mei; Cao, Ru'an; Yun, Zhongqiao; Lü, Yunlai; Ma, Hongli; Guo, Nan; Yu, Qilu; Ness, Paul; Shan, Hua

    2013-10-01

    A total of 2%-2.9% of the population in China is infected with hepatitis C virus (HCV). This study estimated the prevalence and incidence of HCV among Chinese blood donors. We examined whole blood and apheresis platelet donations at five Chinese blood centers in 2008 to 2010. All donations were screened using two rounds of testing for alanine aminotransferase, antibody to human immunodeficiency virus Types 1 and 2, hepatitis B surface antigen, anti-HCV, and syphilis. Screening reactivity is defined by a reactive result in one or both rounds of screening tests. Confirmatory tests (Ortho third-generation HCV enzyme immunoassay, Johnson & Johnson) were performed on anti-HCV screening-reactive samples. Confirmatory positive rates among first-time donors (prevalence) and repeat donors (incidence) were calculated by blood center and demographic categories. Donor characteristics associated with HCV confirmatory status among first-time donors were examined using trend test and multivariable logistic regression analysis. Among 821,314 donations, 40% came from repeat donors. The overall anti-HCV screening-reactive rate was 0.48%. Estimated HCV prevalence was 235 per 100,000 first-time donors; incidence was 10 per 100,000 person-years in repeat donors. In multivariable logistic regression analysis, first-time donors older than 25 years displayed higher HCV prevalence than the younger donors. Less education is associated with higher HCV prevalence. Donors 26 to 35 years old and those above 45 years displayed the highest incidence rate. High prevalence and incidence in donors indicate high residual risks for transfusion-transmitted HCV in Chinese patients. Implementation of minipool nucleic acid testing in routine donation screening may prevent a substantial number of transfusion-transmitted HCV infections. © 2013 American Association of Blood Banks.

  15. Most routine laboratory testing of pediatric psychiatric patients in the emergency department is not medically necessary.

    PubMed

    Donofrio, J Joelle; Horeczko, Timothy; Kaji, Amy; Santillanes, Genevieve; Claudius, Ilene

    2015-05-01

    We examined the patient characteristics and hospital charges associated with routine medical clearance laboratory screening tests in 1,082 children younger than age eighteen who were brought to the emergency department (ED) for involuntary mental health holds--that is, each patient was brought to the ED to be evaluated for being a danger to him- or herself or to others, for being gravely disabled (unable to meet his or her basic needs due to a mental disorder), or both--from July 2009 to December 2010. Testing was performed on 871 of the children; all patients also received a clinical examination. The median charge for blood and urine testing together was $1,235, and the most frequent ordering pattern was the full comprehensive panel of tests. Of the patients with a nonconcerning clinical examination, 94.3 percent also had clinically nonsignificant test results. When we extrapolated cost savings to the national level, omitting routine screening laboratory tests in the population of pediatric patients presenting to the ED on an involuntary psychiatric hold with nonconcerning clinical exams could represent up to $90 million in savings annually, without reducing the ability to screen for emergency medical conditions. Provider-initiated diagnostic testing instead of routine screening would lead to significantly lower charges to the ED and the patient. Project HOPE—The People-to-People Health Foundation, Inc.

  16. Testing Women With Endometrial Cancer for Lynch Syndrome: Should We Test All?

    PubMed Central

    Ma, Jun; Ledbetter, Nancy; Glenn, Lyn

    2013-01-01

    Women with Lynch syndrome (LS) are at equal or higher risk for gynecologic cancers compared with their risk for colorectal cancer (CRC). Endometrial cancer (EC) often precedes CRC as patients’ sentinel malignancy. Identifying these patients is believed to reduce their substantial risk for synchronous and metachronous tumors and has profound implications for reducing cancer-related morbidity and mortality in other family members. Routine screening of patients with CRC for LS has become increasingly common, but routine screening for LS in women with EC is rarely performed. Current screening guidelines for identifying LS in women with EC vary but rely heavily on patient age and personal/family history, with or without incorporation of tumor pathology. Because each of these strategies misses a significant proportion of women with LS, more inclusive screening strategies that make good economic and clinical sense are needed. In recent years, emerging medicoeconomic evidence supports the fact that screening EC patients for LS may be cost-effective. Implementation of such a strategy requires multidisciplinary collaboration and partnership. PMID:25032011

  17. Optimization of electrostatic dual-grid beam-deflection system

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.; Lathem, W. C.; Power, J. L.; Banks, B. A.

    1972-01-01

    Tests were performed to minimize accelerator grid erosion of a 5-cm diameter Kaufman ion thruster due to direct beam impingement. Several different screen hole diameters, pillow-shape-square screen holes, and dished screen grids were tried. The optimization was accomplished by copper plating the accelerator grid before testing each grid configuration on a thruster for a 2-hour run. The thruster beam sputtered copper and molybdenum from the accelerator grid where the beam impinged. The observed erosion patterns and measured accelerator currents were used to determine how to modify the accelerator system. The lowest erosion was obtained for a 50-percent open area pillow-shape-square-aperture screen grid, dished 0.043 centimeter convex toward the accelerator grid, which was positioned with the center of the screen grid 0.084 centimeter from the accelerator grid. During this investigation the accelerator current was reduced from 120 to 55 microamperes and was also more uniformly distributed over the area of the accelerator grid.

  18. Haemoglobinopathy diagnosis: algorithms, lessons and pitfalls.

    PubMed

    Bain, Barbara J

    2011-09-01

    Diagnosis of haemoglobinopathies, including thalassaemias, can result from either a clinical suspicion of a disorder of globin chain synthesis or from follow-up of an abnormality detected during screening. Screening may be carried out as part of a well defined screening programme or be an ad hoc or opportunistic test. Screening may be preoperative, neonatal, antenatal, preconceptual, premarriage or targeted at specific groups perceived to be at risk. Screening in the setting of haemoglobinopathies may be directed at optimising management of a disorder by early diagnosis, permitting informed reproductive choice or preventing a serious disorder by offering termination of pregnancy. Diagnostic methods and algorithms will differ according to the setting. As the primary test, high performance liquid chromatography is increasingly used and haemoglobin electrophoresis less so with isoelectric focussing being largely confined to screening programmes and referral centres, particularly in newborns. Capillary electrophoresis is being increasingly used. All these methods permit only a presumptive diagnosis with definitive diagnosis requiring either DNA analysis or protein analysis, for example by tandem mass spectrometry. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Is high pressure liquid chromatography an effective screening tool for characterization of molecular defects in hemoglobinopathies?

    PubMed

    Moorchung, Nikhil; Phillip, Joseph; Sarkar, Ravi Shankar; Prasad, Rupesh; Dutta, Vibha

    2013-01-01

    Hemoglobinopathies constitute entities that are generated by either abnormal hemoglobin or thalassemias. high pressure liquid chromatography (HPLC) is one of the best methods for screening and detection of various hemoglobinopathies but it has intrinsic interpretive problems. The study was designed to evaluate the different mutations seen in cases of hemoglobinopathies and compare the same with screening tests. 68 patients of hemoglobinopathies were screened by HPLC. Mutation studies in the beta globin gene was performed using the polymerase chain reaction (PCR)-based allele-specific Amplification Refractory Mutation System (ARMS). Molecular analysis for the sickle cell mutation was done by standard methods. The IVS 1/5 mutation was the commonest mutation seen and it was seen in 26 (38.23%) of the cases. This was followed by the IVS 1/1, codon 41/42, codon 8/9, del 22 mutation, codon 15 mutation and the -619 bp deletion. No mutation was seen in eight cases. There was a 100% concordance between the sickle cell trait as diagnosed by HPLC and genetic testing. Our study underlies the importance of molecular testing in all cases of hemoglobinopathies. Although HPLC is a useful screening tool, molecular testing is very useful in accurately diagnosing the mutations. Molecular testing is especially applicable in cases with an abnormal hemoglobin (HbD, HbE and HbS) because there may be a concomitant inheritance of a beta thalassemia mutation. Molecular testing is the gold standard when it comes to the diagnosis of hemoglobinopathies.

  20. Hit Identification and Optimization in Virtual Screening: Practical Recommendations Based Upon a Critical Literature Analysis

    PubMed Central

    Zhu, Tian; Cao, Shuyi; Su, Pin-Chih; Patel, Ram; Shah, Darshan; Chokshi, Heta B.; Szukala, Richard; Johnson, Michael E.; Hevener, Kirk E.

    2013-01-01

    A critical analysis of virtual screening results published between 2007 and 2011 was performed. The activity of reported hit compounds from over 400 studies was compared to their hit identification criteria. Hit rates and ligand efficiencies were calculated to assist in these analyses and the results were compared with factors such as the size of the virtual library and the number of compounds tested. A series of promiscuity, drug-like, and ADMET filters were applied to the reported hits to assess the quality of compounds reported and a careful analysis of a subset of the studies which presented hit optimization was performed. This data allowed us to make several practical recommendations with respect to selection of compounds for experimental testing, defining hit identification criteria, and general virtual screening hit criteria to allow for realistic hit optimization. A key recommendation is the use of size-targeted ligand efficiency values as hit identification criteria. PMID:23688234

Top