Sample records for screening tests falsely

  1. Neuroblastoma Screening

    MedlinePlus

    ... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  2. Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  3. Risks of Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  4. Risk of breast cancer after false-positive results in mammographic screening.

    PubMed

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  5. Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening

    PubMed Central

    Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.

    2009-01-01

    PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838

  6. Cumulative risk of false positive test in relation to breast symptoms in mammography screening: a historical prospective cohort study.

    PubMed

    Singh, Deependra; Pitkäniemi, Janne; Malila, Nea; Anttila, Ahti

    2016-09-01

    Mammography has been found effective as the primary screening test for breast cancer. We estimated the cumulative probability of false positive screening test results with respect to symptom history reported at screen. A historical prospective cohort study was done using individual screening data from 413,611 women aged 50-69 years with 2,627,256 invitations for mammography screening between 1992 and 2012 in Finland. Symptoms (lump, retraction, and secretion) were reported at 56,805 visits, and 48,873 visits resulted in a false positive mammography result. Generalized linear models were used to estimate the probability of at least one false positive test and true positive at screening visits. The estimates were compared among women with and without symptoms history. The estimated cumulative probabilities were 18 and 6 % for false positive and true positive results, respectively. In women with a history of a lump, the cumulative probabilities of false positive test and true positive were 45 and 16 %, respectively, compared to 17 and 5 % with no reported lump. In women with a history of any given symptom, the cumulative probabilities of false positive test and true positive were 38 and 13 %, respectively. Likewise, women with a history of a 'lump and retraction' had the cumulative false positive probability of 56 %. The study showed higher cumulative risk of false positive tests and more cancers detected in women who reported symptoms compared to women who did not report symptoms at screen. The risk varies substantially, depending on symptom types and characteristics. Information on breast symptoms influences the balance of absolute benefits and harms of screening.

  7. Implications of false-positive results for future cancer screenings.

    PubMed

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  8. The efficacy and cost of alternative strategies for systematic screening for type 2 diabetes in the U.S. population 45-74 years of age.

    PubMed

    Johnson, Susan L; Tabaei, Bahman P; Herman, William H

    2005-02-01

    To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.

  9. False-positive cancer screens and health-related quality of life.

    PubMed

    McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R

    2004-01-01

    By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.

  10. Cross-reactivity between Lyme and syphilis screening assays: Lyme disease does not cause false-positive syphilis screens.

    PubMed

    Patriquin, Glenn; LeBlanc, Jason; Heinstein, Charles; Roberts, Catherine; Lindsay, Robbin; Hatchette, Todd F

    2016-03-01

    Increased rates of Lyme disease and syphilis in the same geographic area prompted an assessment of screening test cross-reactivity. This study supports the previously described cross-reactivity of Lyme screening among syphilis-positive sera and reports evidence against the possibility of false-positive syphilis screening tests resulting from previous Borrelia burgdorferi infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    PubMed

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Development and verification of a model for estimating the screening utility in the detection of PCBs in transformer oil.

    PubMed

    Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya

    2014-01-01

    A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.

  13. Nonbleeding adenomas: Evidence of systematic false-negative fecal immunochemical test results and their implications for screening effectiveness-A modeling study.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein

    2016-06-01

    If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.

  14. Are overreferrals on developmental screening tests really a problem?

    PubMed

    Glascoe, F P

    2001-01-01

    Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.

  15. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  16. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  17. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  18. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  19. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  20. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  1. Performance Characteristics of the Reverse Syphilis Screening Algorithm in a Population With a Moderately High Prevalence of Syphilis.

    PubMed

    Rourk, Angela R; Nolte, Frederick S; Litwin, Christine M

    2016-11-01

    With the recent introduction of automated treponemal tests, a new reverse syphilis algorithm has been proposed and now used by many clinical laboratories. We analyzed the impact of instituting the reverse screening syphilis algorithm in a laboratory that serves a geographic area with a moderately high prevalence of syphilis infection. Serum samples sent for syphilis testing were tested using a treponemal enzyme immunoassay (EIA) as the screening assay. EIA reactive samples were tested by rapid plasma reagin (RPR) and titered to end point if reactive. RPR nonreactive samples were analyzed by the Treponema pallidum particle agglutination test (TP-PA). Pertinent medical records were reviewed for false-reactive screens and samples with evidence of past syphilis infection. Among 10,060 patients tested, 502 (5%) were reactive on the initial EIA screen. The RPR was reactive in 150 (1.5%). TP-PA testing determined that 103 (1.0%) were falsely reactive on initial EIA screen. The reverse screening algorithm, however, identified 242 (2.4%) with evidence of latent, secondary, or past syphilis, 21 of whom had no or unknown prior treatment with antibiotics. Despite a 1.0% false-reactive rate, the reverse syphilis algorithm detected 21 patients with possible latent syphilis that may have gone undetected by traditional syphilis screening. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  3. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  4. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  5. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  6. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  7. Prevention. How much harm? How much benefit? 3. Physical, psychological and social harm.

    PubMed Central

    Marshall, K G

    1996-01-01

    Harm caused by preventive programs may be physical, psychological, social or, if informed consent has not been obtained, ethical. Adverse effects of preventive screening programs may occur at any of the three levels of the "screening cascade", the screening procedure itself, the investigation of abnormal results of screening tests or the treatment of detected abnormalities or diseases. The greatest harm occurs at the second and third levels. Examples of procedures that may cause physical harm are venipuncture, mammography, colonoscopy, breast biopsy, transrectal ultrasonography, prostate biopsy, weight-reducing and cholesterol-lowering diets and radical prostatectomy. The psychological and social harm of preventive programs involves anticipated discomfort or perception of adverse effects of preventive interventions; unpleasant interactions with health care workers, time required for preventive programs, excessive overall awareness of health, anxiety over the results of a screening test implications of a positive screening test, consequences of being labelled as "sick" or "at risk," psychopathologic effects induced directly by preventive programs and, in the case of a false-negative test result, false assurance of disease-free status. Since the positive predictive value of screening tests in the general population is always low, most abnormal test results are "false-positive," these engender a great deal of psychological discuss among patients. PMID:8800074

  8. Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.

    PubMed

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.

  9. Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients

    PubMed Central

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310

  10. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  11. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  12. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  13. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  14. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  15. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  16. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  17. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    PubMed

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  18. Diagnostic accuracy of blood centers in the screening of blood donors for viral markers

    PubMed Central

    Dogbe, Elliot Eli; Arthur, Fareed

    2015-01-01

    Introduction Blood transfusion still remains a life saving intervention in almost all healthcare facilities worldwide. Screening of blood donors/blood units is done in almost every blood bank facility before the blood units/blood components are transfused to prevent transfusion-transmissible infections. The kind of testing kits or the methods used by a facility and the technical expertise of the personnel greatly affects the screening results of a facility. This study was aimed at evaluating the diagnostic accuracy of five hospital-based blood bank testing facilities (Komfo Anokye Teaching Hospital KNUST, Kwame Nkrumah University of Science and Technology, Agogo, Bekwai and Sunyani) that used rapid immunochromatograhic assays (RIA) in screening blood donors/blood units in Ghana. Methods Blood samples (300) from the five testing facilities and their screening results for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV) and human immunodeficiency virus (HIV) using RIAs were obtained. All the samples were then analysed for the three viral markers using 3rd generational enzyme linked immunosorbent assay (ELISA) kit as the gold standard. Results The mean false positive for HBsAg was 2.2% with Bekwai testing facility having the highest of 4.4%. For HCV, the mean false positive was 2.8% with Agogo and Bekwai testing facilities having the highest of 8.7% respectively. For HIV screening, the mean false positive was 11.1% with Bekwai testing facility having the highest of 28.0%. The mean false negative for the facilities were 3.0% for HBV, 75.0% for HCV and 0.0% for HIV with KATH having the highest of 6.3% for HBV, Bekwai having the highest of 100% for HCV and no facility showing false negative for HIV. Mean sensitivity of the screening procedure for the facilities was 97.0%, 25.0% and 100.0% whilst the mean specificity was 97.8%, 97.2% and 88.9% for HBV, HCV and HIV respectively. Statistical comparison among the testing facilities showed no significant differences among the various testing centres for HBV screening; however, significant differences were obtained for HCV and HIV screening. Conclusion This study has shown that there is no standardised screening procedure for blood bank testing facilities in the country. There is therefore an urgent need for an internal and external control body to oversee screening procedures in blood banks across the country. PMID:26090067

  19. Screening for gonorrhoea using samples collected through the English National Chlamydia Screening Programme and risk of false positives: a national survey of Local Authorities

    PubMed Central

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-01-01

    Objectives To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. Design and setting During May–July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15–24 years. Main outcome measures (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. Results 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450–4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17–67%. Conclusions Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. PMID:25324326

  20. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  1. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  2. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  3. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    PubMed

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  4. Screening for subclinical Cushing's syndrome in type 2 diabetes mellitus: low false-positive rates with nocturnal salivary cortisol.

    PubMed

    Gagliardi, L; Chapman, I M; O'Loughlin, P; Torpy, D J

    2010-04-01

    The diagnosis of subclinical Cushing's syndrome (SCS) is important, but its relative rarity amongst patients with common metabolic disorders requires a simple test with a low false-positive rate. Using nocturnal salivary cortisol (NSC), which we first validated in patients with suspected and proven Cushing's syndrome, we screened 106 overweight patients with type 2 diabetes mellitus, a group at high risk of SCS and nontumoral hypothalamic-pituitary-adrenal axis perturbations. Our hypothesis was that a lower false-positive rate with NSC was likely, compared with that reported with the dexamethasone suppression test (DST) (10-20%), currently the foundation of diagnosis of SCS. No participant had clinically apparent Cushing's syndrome. Three participants had an elevated NSC but further testing excluded SCS. In this study, NSC had a lower false-positive rate (3%) than previously reported for the DST. Given the reported excellent performance of NSC in detection of hypercortisolism, the low false-positive rate in SCS suggests NSC may be superior to the DST for SCS screening. The NSC and DST should be compared directly in metabolic disorder patients; although our data suggest the patient group will need to be substantially larger to definitively determine the optimal screening test. Georg Thieme Verlag KG Stuttgart New York.

  5. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  6. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  7. [Systematic screening of deafness at a maternity ward using evoked otoacoustic emissions: practical aspects and parental attitudes].

    PubMed

    Moulin, A; Ferber-Viart, C; Berland, M; Dubreuil, C; Duclaux, R

    2001-09-01

    Evaluation of the feasibility and parental attitudes towards a hearing screening programme using evoked otoacoustic emissions, implemented in a maternity ward in France. A hearing screening test using transiently evoked otoacoustic emissions (TEOAE) was proposed to each baby, and an anonymous questionnaire was given to parents to assess their attitudes towards the screening procedure. Although the refusal of the test reached 16% (mainly during the first two weeks of the program), more than 92% of parents judged the test as being useful, and 65% wished it to be systematically done. However, nearly 35% of parents admitted to have a low level anxiety about being unnecessarily worried by the test results. One hundred and twenty-four babies were screened. Fifty three per cent of the tests have been performed in less than ten minutes, with an average of 12.2 minutes. This duration does not include delays due to programme and babies management. False positive rate (uni or bilateral fail) was 10.5% at the first stage. Repeating the test before discharge decreased the false positive rate to 6.5%. Although limited in time, this study shows that a systematic hearing screening programme using TEOAE is possible and should be done in France. False positive rate was below 7%, and the test was considered as useful by more than 90% of parents, although knowledge about deafness in childhood and its consequences were clearly insufficient.

  8. Screening for gonorrhoea using samples collected through the English national chlamydia screening programme and risk of false positives: a national survey of local authorities.

    PubMed

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-10-16

    To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. During May-July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15-24 years. (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450-4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17-67%. Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    PubMed

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  10. Towards Risk-Based Test Protocols: Estimating the Contribution of Intensive Testing to the UK Bovine Tuberculosis Problem

    PubMed Central

    van Dijk, Jan

    2013-01-01

    Eradicating disease from livestock populations involves the balancing act of removing sufficient numbers of diseased animals without removing too many healthy individuals in the process. As ever more tests for bovine tuberculosis (BTB) are carried out on the UK cattle herd, and each positive herd test triggers more testing, the question arises whether ‘false positive’ results contribute significantly to the measured BTB prevalence. Here, this question is explored using simple probabilistic models of test behaviour. When the screening test is applied to the average UK herd, the estimated proportion of test-associated false positive new outbreaks is highly sensitive to small fluctuations in screening test specificity. Estimations of this parameter should be updated as a priority. Once outbreaks have been confirmed in screening-test positive herds, the following rounds of intensive testing with more sensitive, albeit less specific, tests are highly likely to remove large numbers of false positive animals from herds. Despite this, it is unlikely that significantly more truly infected animals are removed. BTB test protocols should become based on quantified risk in order to prevent the needless slaughter of large numbers of healthy animals. PMID:23717517

  11. A prospective clinical trial to compare the performance of dried blood spots prenatal screening for Down's syndrome with conventional non-invasive testing technology.

    PubMed

    Hu, Huiying; Jiang, Yulin; Zhang, Minghui; Liu, Shanying; Hao, Na; Zhou, Jing; Liu, Juntao; Zhang, Xiaojin; Ma, Liangkun

    2017-03-01

    To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down's syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down's syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down's syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down's syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a "before and after" two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down's syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down's syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down's syndrome and to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. Results demonstrate that fetal cfDNA can significantly reduce false-positive rate close to none while distinguishing all true positives. Thus, we recommend that fetal cfDNA analysis to be utilized as a secondary screening tool atop of the primary blood protein screening to further minimize the capacity of undesirable invasive diagnostic operations.

  12. Prenatal Genetic Screening Tests

    MedlinePlus

    ... information about the rates of false-positive and false-negative results for each test. What should I consider when deciding whether to have prenatal genetic testing? It is your choice whether to have prenatal testing. Your personal beliefs and values are important factors in the decision ...

  13. 49 CFR 1546.407 - Training, testing, and knowledge of individuals who perform screening functions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Training, testing, and knowledge of individuals... Carrier Conducts Screening § 1546.407 Training, testing, and knowledge of individuals who perform... test prescribed by TSA. (f) Knowledge requirements. Each foreign air carrier must ensure that...

  14. Prescription drugs associated with false-positive results when using faecal immunochemical tests for colorectal cancer screening.

    PubMed

    Ibáñez-Sanz, Gemma; Garcia, Montse; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Domènech, Xènia; Vidal, Carmen; Soriano, Antonio; Moreno, Víctor

    2016-10-01

    The most common side effect in population screening programmes is a false-positive result which leads to unnecessary risks and costs. To identify factors associated with false-positive results in a colorectal cancer screening programme with the faecal immunochemical test (FIT). Cross-sectional study of 472 participants with a positive FIT who underwent colonoscopy for confirmation of diagnosis between 2013 and 2014. A false-positive result was defined as having a positive FIT (≥20μg haemoglobin per gram of faeces) and follow-up colonoscopy without intermediate/high-risk lesions or cancer. Women showed a two-fold increased likelihood of a false-positive result compared with men (adjusted OR, 2.3; 95%CI, 1.5-3.4), but no female-specific factor was identified. The other variables associated with a false-positive result were successive screening (adjusted OR, 1.5; 95%CI, 1.0-2.2), anal disorders (adjusted OR, 3.1; 95%CI, 2.1-4.5) and the use of proton pump inhibitors (adjusted OR, 1.8; 95%CI, 1.1-2.9). Successive screening and proton pump inhibitor use were associated with FP in men. None of the other drugs were related to a false-positive FIT. Concurrent use of proton pump inhibitors at the time of FIT might increase the likelihood of a false-positive result. Further investigation is needed to determine whether discontinuing them could decrease the false-positive rate. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Newborn screening for citrin deficiency and carnitine uptake defect using second-tier molecular tests.

    PubMed

    Wang, Li-Yun; Chen, Nien-I; Chen, Pin-Wen; Chiang, Shu-Chuan; Hwu, Wuh-Liang; Lee, Ni-Chung; Chien, Yin-Hsiu

    2013-02-10

    Tandem mass spectrometry (MS/MS) analysis is a powerful tool for newborn screening, and many rare inborn errors of metabolism are currently screened using MS/MS. However, the sensitivity of MS/MS screening for several inborn errors, including citrin deficiency (screened by citrulline level) and carnitine uptake defect (CUD, screened by free carnitine level), is not satisfactory. This study was conducted to determine whether a second-tier molecular test could improve the sensitivity of citrin deficiency and CUD detection without increasing the false-positive rate. Three mutations in the SLC25A13 gene (for citrin deficiency) and one mutation in the SLC22A5 gene (for CUD) were analyzed in newborns who demonstrated an inconclusive primary screening result (with levels between the screening and diagnostic cutoffs). The results revealed that 314 of 46 699 newborns received a second-tier test for citrin deficiency, and two patients were identified; 206 of 30 237 newborns received a second-tier testing for CUD, and one patient was identified. No patients were identified using the diagnostic cutoffs. Although the incidences for citrin deficiency (1:23 350) and CUD (1:30 000) detected by screening are still lower than the incidences calculated from the mutation carrier rates, the second-tier molecular test increases the sensitivity of newborn screening for citrin deficiency and CUD without increasing the false-positive rate. Utilizing a molecular second-tier test for citrin deficiency and carnitine transporter deficiency is feasible.

  16. Role of Protein Biomarkers in the Detection of High-Grade Disease in Cervical Cancer Screening Programs

    PubMed Central

    Brown, Charlotte A.; Bogers, Johnannes; Sahebali, Shaira; Depuydt, Christophe E.; De Prins, Frans; Malinowski, Douglas P.

    2012-01-01

    Since the Pap test was introduced in the 1940s, there has been an approximately 70% reduction in the incidence of squamous cell cervical cancers in many developed countries by the application of organized and opportunistic screening programs. The efficacy of the Pap test, however, is hampered by high interobserver variability and high false-negative and false-positive rates. The use of biomarkers has demonstrated the ability to overcome these issues, leading to improved positive predictive value of cervical screening results. In addition, the introduction of HPV primary screening programs will necessitate the use of a follow-up test with high specificity to triage the high number of HPV-positive tests. This paper will focus on protein biomarkers currently available for use in cervical cancer screening, which appear to improve the detection of women at greatest risk for developing cervical cancer, including Ki-67, p16INK4a, BD ProEx C, and Cytoactiv HPV L1. PMID:22481919

  17. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2010-10-01 2010-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  18. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2014-10-01 2014-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  19. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2012-10-01 2012-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  20. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2013-10-01 2013-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  1. 42 CFR 410.18 - Diabetes screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... this subpart are met: (1) Fasting blood glucose test. (2) Post-glucose challenges including, but not...-pregnant adults, a 2-hour post glucose challenge test alone. (3) Other tests as determined by the Secretary... 42 Public Health 2 2011-10-01 2011-10-01 false Diabetes screening tests. 410.18 Section 410.18...

  2. False negative rates in Drosophila cell-based RNAi screens: a case study

    PubMed Central

    2011-01-01

    Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254

  3. Screening for Sex Chromosome Aneuploidy by Cell-Free DNA Testing: Patient Choice and Performance.

    PubMed

    Bevilacqua, Elisa; Ordóñez, Elena; Hurtado, Ivan; Rueda, Laura; Mazzone, Eléonora; Cirigliano, Vincenzo; Jani, Jacques C

    2017-08-23

    To study patient choice regarding testing for sex chromosome aneuploidy (SCA) and the performance of cell-free DNA (cfDNA) screening for SCA. Patient choice regarding screening for SCA and factors influencing this choice were evaluated in a single center. In a subsequent two-center study, cases that screened positive for SCA were analyzed to determine the positive predictive value (PPV) for each SCA. In all, 1,957 (61.9%) of the 3,162 patients undergoing cfDNA testing opted for SCA screening. Regression analysis demonstrated that independent predictors of a patient's decision for SCA were earlier gestational age, spontaneous conception, and cfDNA chosen as a primary method of screening. A total of 161 cases screened positive for SCA and follow-up data were available for 118 (73.3%). Forty-six of the 61 cases of 45,X were false-positive results and 15 were concordant with the fetal karyotype (PPV = 24.6%). Seventeen of the 22 cases of 47,XXX were false positive and 5 concordant (PPV = 22.7%). Eleven of the 30 cases of 47,XXY were false positive and 19 concordant (PPV = 63.3%). All 5 cases of 47,XYY were correctly identified, thus yielding a PPV of 100%. More than half of the patients undergoing cfDNA aneuploidy screening also opted for SCA testing, but they were less likely to do so in the presence of an increased risk of trisomy. SCAs involving the X chromosome had a lower PPV than those involving the Y chromosome. © 2017 S. Karger AG, Basel.

  4. 49 CFR 1544.407 - Training, testing, and knowledge of individuals who perform screening functions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Training, testing, and knowledge of individuals... Qualifications When the Aircraft Operator Performs Screening § 1544.407 Training, testing, and knowledge of... on-the-job training test prescribed by TSA. (f) Knowledge requirements. Each aircraft operator must...

  5. Sensitivity of fetal RHD screening for safe guidance of targeted anti-D immunoglobulin prophylaxis: prospective cohort study of a nationwide programme in the Netherlands.

    PubMed

    de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C

    2016-11-07

     To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN:  Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined.  Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting.  25 789 RhD negative pregnant women.  Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme.  A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme.  Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Putting a New Filter On Cancer Screening.

    PubMed

    Huff, Charlotte

    2016-10-01

    Experts are rethinking routine cancer screening. Genetic tests could be the answer. They may add upfront expense, but might eventually lead to savings by winnowing out unnecessary screening. Concern about false positives helps push this movement along.

  7. Reducing false negatives in clinical practice: the role of neural network technology.

    PubMed

    Mango, L J

    1996-10-01

    The fact that some cervical smears result in false-negative findings is an unavoidable and unpredictable consequence of the conventional (manual microscopic) method of screening. Errors in the detection and interpretation of abnormality are cited as leading causes of false-negative cytology findings; these are random errors that are not known to correlate with any patient risk factor, which makes the false-negative findings a "silent" threat that is difficult to prevent. Described by many as a labor-intensive procedure, the microscopic evaluation of a cervical smear involves a detailed search among hundreds of thousands of cells on each smear for a possible few that may indicate abnormality. Investigations into causes of false-negative findings preceding the discovery of high-grade lesions found that many smears had very few diagnostic cells that were often very small in size. These small cells were initially overlooked or misinterpreted and repeatedly missed on rescreening. PAPNET testing is designed to supplement conventional screening by detecting abnormal cells that initially may have been missed by microscopic examination. This interactive system uses neural networks, a type of artificial intelligence well suited for pattern recognition, to automate the arduous search for abnormality. The instrument focuses the review of suspicious cells by a trained cytologist. Clinical studies indicate that PAPNET testing is sensitive to abnormality typically missed by conventional screening and that its use as a supplemental test improves the accuracy of screening.

  8. Breast cancer detection risk in screening mammography after a false-positive result.

    PubMed

    Castells, X; Román, M; Romero, A; Blanch, J; Zubizarreta, R; Ascunce, N; Salas, D; Burón, A; Sala, M

    2013-02-01

    False-positives are a major concern in breast cancer screening. However, false-positives have been little evaluated as a prognostic factor for cancer detection. Our aim was to evaluate the association of false-positive results with the cancer detection risk in subsequent screening participations over a 17-year period. This is a retrospective cohort study of 762,506 women aged 45-69 years, with at least two screening participations, who underwent 2,594,146 screening mammograms from 1990 to 2006. Multilevel discrete-time hazard models were used to estimate the adjusted odds ratios (OR) of breast cancer detection in subsequent screening participations in women with false-positive results. False-positives involving a fine-needle aspiration cytology or a biopsy had a higher cancer detection risk than those involving additional imaging procedures alone (OR = 2.69; 95%CI: 2.28-3.16 and OR = 1.81; 95%CI: 1.70-1.94, respectively). The risk of cancer detection increased substantially if women with cytology or biopsy had a familial history of breast cancer (OR = 4.64; 95%CI: 3.23-6.66). Other factors associated with an increased cancer detection risk were age 65-69 years (OR = 1.84; 95%CI: 1.67-2.03), non-attendance at the previous screening invitation (OR = 1.26; 95%CI: 1.11-1.43), and having undergone a previous benign biopsy outside the screening program (OR = 1.24; 95%CI: 1.13-1.35). Women with a false-positive test have an increased risk of cancer detection in subsequent screening participations, especially those with a false-positive result involving cytology or biopsy. Understanding the factors behind this association could provide valuable information to increase the effectiveness of breast cancer screening. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. The clinical impact of a false-positive urine cocaine screening result on a patient's pain management.

    PubMed

    Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L

    2015-06-01

    The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.

  10. 75 FR 28619 - Meeting of the Advisory Committee on Blood Safety and Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ... began prior to the availability of tests for HIV in early 1985. The deferral has existed in its current form since September 1985. This and other related FDA policies are designed to address the major... screened using highly sensitive tests, screening tests can be falsely negative during the ``window period...

  11. Selecting At-Risk First-Grade Readers for Early Intervention: Eliminating False Positives and Exploring the Promise of a Two-Stage Gated Screening Process

    ERIC Educational Resources Information Center

    Compton, Donald L.; Fuchs, Douglas; Fuchs, Lynn S.; Bouton, Bobette; Gilbert, Jennifer K.; Barquero, Laura A.; Cho, Eunsoo; Crouch, Robert C.

    2010-01-01

    The purposes of this study were (a) to identify measures that when added to a base 1st-grade screening battery help eliminate false positives and (b) to investigate gains in efficiency associated with a 2-stage gated screening procedure. We tested 355 children in the fall of 1st grade and assessed for reading difficulty at the end of 2nd grade.…

  12. Performance of two hearing screening protocols in NICU in Shanghai.

    PubMed

    Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin

    2011-10-01

    To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Steroid profiling for congenital adrenal hyperplasia by tandem mass spectrometry as a second-tier test reduces follow-up burdens in a tertiary care hospital: a retrospective and prospective evaluation.

    PubMed

    Seo, Ja Young; Park, Hyung-Doo; Kim, Jong Won; Oh, Hyeon Ju; Yang, Jeong Soo; Chang, Yun Sil; Park, Won Soon; Lee, Soo-Youn

    2014-01-01

    Newborn screening for congenital adrenal hyperplasia (CAH) based on measuring 17-hydroxyprogesterone (17-OHP) by immunoassay generates a number of false-positive results, especially in preterm neonates. We applied steroid profiling by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a second-tier test in newborns with positive CAH screening and evaluated its clinical utility in a tertiary care hospital setting. By performing a 4-year retrospective data review, we were able to test 121 dried blood spots from newborns with positive CAH screening for 17-OHP, androstenedione and cortisol levels by LC-MS/MS. We prospectively evaluated the clinical utility of steroid profiling after the implementation of steroid profiling as a second-tier test in our routine clinical practice. During the 2-year prospective study period, 104 cases with positive initial screening by FIA were tested by LC-MS/MS. Clinical and laboratory follow-up were performed for at least 6 months. The preterm neonates accounted for 50.7% (76/150) and 70.4% (88/125) of screening-positive cases in retrospective and prospective cohorts, respectively. By applying steroid profiling as a second-tier test for positive CAH screening, we eliminated all false-positive results and decreased the median follow-up time from 75 to 8 days. Our data showed that steroid profiling reduced the burden of follow-up exams by improving the positive predictive value of the CAH screening program. The use of steroid profiling as a second-tier test for positive CAH screening will improve clinical practice particularly in a tertiary care hospital setting where positive CAH screening from preterm neonates is frequently encountered.

  14. Application of Titration-Based Screening for the Rapid Pilot Testing of High-Throughput Assays.

    PubMed

    Zhang, Ji-Hu; Kang, Zhao B; Ardayfio, Ophelia; Ho, Pei-i; Smith, Thomas; Wallace, Iain; Bowes, Scott; Hill, W Adam; Auld, Douglas S

    2014-06-01

    Pilot testing of an assay intended for high-throughput screening (HTS) with small compound sets is a necessary but often time-consuming step in the validation of an assay protocol. When the initial testing concentration is less than optimal, this can involve iterative testing at different concentrations to further evaluate the pilot outcome, which can be even more time-consuming. Quantitative HTS (qHTS) enables flexible and rapid collection of assay performance statistics, hits at different concentrations, and concentration-response curves in a single experiment. Here we describe the qHTS process for pilot testing in which eight-point concentration-response curves are produced using an interplate asymmetric dilution protocol in which the first four concentrations are used to represent the range of typical HTS screening concentrations and the last four concentrations are added for robust curve fitting to determine potency/efficacy values. We also describe how these data can be analyzed to predict the frequency of false-positives, false-negatives, hit rates, and confirmation rates for the HTS process as a function of screening concentration. By taking into account the compound pharmacology, this pilot-testing paradigm enables rapid assessment of the assay performance and choosing the optimal concentration for the large-scale HTS in one experiment. © 2013 Society for Laboratory Automation and Screening.

  15. [Comparison of eight screening tests for ant-HCV antibody].

    PubMed

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  16. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  17. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  18. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  19. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  20. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  1. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    PubMed

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  2. Dietary flavonols contribute to false-positive elevation of homovanillic acid, a marker of catecholamine-secreting tumors.

    PubMed

    Combet, Emilie; Lean, Michael E J; Boyle, James G; Crozier, Alan; Davidson, D Fraser

    2011-01-14

    Urinary homovanillic acid (HVA) measurement is used routinely as a marker of the first test for the screening of catecholamine-secreting tumors and dopamine metabolism, but generates a large number of false-positive results. With no guidelines for dietary restrictions prior to the test, we hypothesize that consumption of flavonol-rich foods (such as onions, tomatoes, tea) prior to urinary catecholamine screening could be responsible for false-positive urinary HVA in healthy subjects. A randomized, crossover dietary intervention was carried out in healthy subjects (n=17). Volunteers followed either a low or high-flavonol diet, for a duration of 3 days, prior to providing a 24-h urine sample for HVA measurement using a routine, validated liquid chromatography method as well as a gas chromatography-mass spectrometry method. Dietary flavonol intake significantly increased urinary HVA excretion (p < 0.001), with 3 out of 17 volunteers (20%) exceeding the 40 μmol/24 h upper limit of normal for HVA excretion (false-positive result). Dietary flavonols commonly found in foodstuff such as tomatoes, onions, and tea, interfered with the routine urinary HVA screening test and should be avoided in the three-day run-up to the test. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Behavioral phenotyping of mice in pharmacological and toxicological research.

    PubMed

    Karl, Tim; Pabst, Reinhard; von Hörsten, Stephan

    2003-07-01

    The evaluation of behavioral effects is an important component for the in vivo screening of drugs or potentially toxic compounds in mice. Ideally, such screening should be composed of monitoring general health, sensory functions, and motor abilities, right before specific behavioral domains are tested. A rational strategy in the design and procedure of testing as well as an effective composition of different well-established and reproducible behavioral tests can minimize the risk of false positive and false negative results in drug screening. In the present review we describe such basic considerations in planning experiments, selecting strains of mice, and propose groups of behavioral tasks suitable for a reliable detection of differences in specific behavioral domains in mice. Screening of general health and neurophysiologic functions (reflexes, sensory abilities) and motor function (pole test, wire hang test, beam walking, rotarod, accelerod, and footprint) as well as specific hypothesis-guided testing in the behavioral domains of learning and memory (water maze, radial maze, conditioned fear, and avoidance tasks), emotionality (open field, hole board, elevated plus maze, and object exploration), nociception (tail flick, hot plate), psychiatric-like conditions (porsolt swim test, acoustic startle response, and prepulse inhibition), and aggression (isolation-induced aggression, spontaneous aggression, and territorial aggression) are described in further detail. This review is designed to describe a general approach, which increases reliability of behavioral screening. Furthermore, it provides an overview on a selection of specific procedures suitable for but not limited to behavioral screening in pharmacology and toxicology.

  4. [Ethical aspects of disclosing information on prenatal screening for Down's syndrome].

    PubMed

    Tóth, Adél; Szabó, János

    2005-02-06

    Giving detailed information on prenatal screening for Down's syndrome is considered as paramount since this medical procedure intends to enhance the patient's self-governance in reproductive issues. Not only the respect for autonomy, but also the increased maternal anxiety and the reproductive decisions following the positive test result demand from the genetic professional to offer the test through genetic counselling. The counsellor's awareness about the expectations of pregnant women and the clarification of her own attitude concerning the screening can contribute to the effectiveness of counselling. The content of information embraces the technical aspects of screening and its consequences, like the description of Down's syndrome, the method of screening, the way of risk assessment, the detection rate, the false positive and false negative test results, the diagnostic procedures, and the termination of pregnancy. Written information leaflets should be completed by personal communication as the combination of these two forms has proved to be the most useful. The process of consultation is influenced by the communication skill of the genetic professional and the information seeking activity of the patient, so doctors should be trained to communicate better and patients should be encouraged to get more information about the screening.

  5. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...

  6. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...

  7. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...

  8. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...

  9. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...

  10. Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists.

    PubMed

    Torres-Mejía, Gabriela; Smith, Robert A; Carranza-Flores, María de la Luz; Bogart, Andy; Martínez-Matsushita, Louis; Miglioretti, Diana L; Kerlikowske, Karla; Ortega-Olvera, Carolina; Montemayor-Varela, Ernesto; Angeles-Llerenas, Angélica; Bautista-Arredondo, Sergio; Sánchez-González, Gilberto; Martínez-Montañez, Olga G; Uscanga-Sánchez, Santos R; Lazcano-Ponce, Eduardo; Hernández-Ávila, Mauricio

    2015-05-16

    An alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries. We evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed. Radiographer's sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7-86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7-57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6-0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms. Given the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists in countries with shortages of radiologists. Further studies are required to assess the effectiveness of different training programs in order to obtain acceptable screening accuracy, as well as the best approaches for the use of non-physician readers to interpret screening mammography.

  11. Maternal cfDNA screening for Down syndrome--a cost sensitivity analysis.

    PubMed

    Cuckle, Howard; Benn, Peter; Pergament, Eugene

    2013-07-01

    This study aimed to determine the principal factors contributing to the cost of avoiding a birth with Down syndrome by using cell-free DNA (cfDNA) to replace conventional screening. A range of unit costs were assigned to each item in the screening process. Detection rates were estimated by meta-analysis and modeling. The marginal cost associated with the detection of additional cases using cfDNA was estimated from the difference in average costs divided by the difference in detection. The main factor was the unit cost of cfDNA testing. For example, replacing a combined test costing $150 with 3% false-positive rate and invasive testing at $1000, by cfDNA tests at $2000, $1500, $1000, and $500, the marginal cost is $8.0, $5.8, $3.6, and $1.4m, respectively. Costs were lower when replacing a quadruple test and higher for a 5% false-positive rate, but the relative importance of cfDNA unit cost was unchanged. A contingent policy whereby 10% to 20% women were selected for cfDNA testing by conventional screening was considerably more cost-efficient. Costs were sensitive to cfDNA uptake. Universal cfDNA screening for Down syndrome will only become affordable by public health purchasers if costs fall substantially. Until this happens, the contingent use of cfDNA is recommended. © 2013 John Wiley & Sons, Ltd.

  12. Do doctors understand the test characteristics of lung cancer screening?

    PubMed

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  13. Consequences of screening in lung cancer: development and dimensionality of a questionnaire.

    PubMed

    Brodersen, John; Thorsen, Hanne; Kreiner, Svend

    2010-08-01

    The objective of this study was to extend the Consequences of Screening (COS) Questionnaire for use in a lung cancer screening by testing for comprehension, content coverage, dimensionality, and reliability. In interviews, the suitability, content coverage, and relevance of the COS were tested on participants in a lung cancer screening program. The results were thematically analyzed to identify the key consequences of abnormal and false-positive screening results. Item Response Theory and Classical Test Theory were used to analyze data. Dimensionality, objectivity, and reliability were established by item analysis, examining the fit between item responses and Rasch models. Eight themes specifically relevant for participants in lung cancer screening results were identified: "self-blame,"focus on symptoms,"stigmatization,"introvert,"harm of smoking,"impulsivity,"empathy," and "regretful of still smoking." Altogether, 26 new items for part I and 16 new items for part II were generated. These themes were confirmed to fit a partial-credit Rasch model measuring different constructs including several of the new items. In conclusion, the reliability and the dimensionality of a condition-specific measure with high content validity for persons having abnormal or false-positive lung cancer screening results have been demonstrated. This new questionnaire called Consequences of Screening in Lung Cancer (COS-LC) covers in two parts the psychosocial experience in lung cancer screening. Part I: "anxiety,"behavior,"dejection,"sleep,"self-blame,"focus on airway symptoms,"stigmatization,"introvert," and "harm of smoking." Part II: "calm/relax,"social network,"existential values,"impulsivity,"empathy," and "regretful of still smoking."

  14. Factors associated with a second deferral among donors eligible for re-entry after a false-positive screening test for syphilis, HCV, HBV and HIV.

    PubMed

    Grégoire, Y; Germain, M; Delage, G

    2018-05-01

    Since 25 May 2010, all donors at our blood centre who tested false-positive for HIV, HBV, HCV or syphilis are eligible for re-entry after further testing. Donors who have a second false-positive screening test, either during qualification for or after re-entry, are deferred for life. This study reports on factors associated with the occurrence of such deferrals. Rates of second false-positive results were compared by year of deferral, transmissible disease marker, gender, age, donor status (new or repeat) and testing platform (same or different) both at qualification for re-entry and afterwards. Chi-square tests were used to compare proportions. Cox regression was used for multivariate analyses. Participation rates in the re-entry programme were 42·1%: 25·6% failed to qualify for re-entry [different platform: 2·7%; same platform: 42·9% (P < 0·0001)]. After re-entry, rates of deferral for second false-positive results were 8·4% after 3 years [different platform: 1·8%; same platform: 21·4% (P < 0·0001)]. Deferral rates were higher for HIV and HCV than for HBV at qualification when tested on the same platform. The risk, when analysed by multivariate analyses, of a second deferral for a false-positive result, both at qualification and 3 years after re-entry, was lower for donors deferred on a different platform; this risk was higher for HIV, HCV and syphilis than for HBV and for new donors if tested on the same platform. Re-entry is more often successful when donors are tested on a testing platform different from the one on which they obtained their first false-positive result. © 2018 International Society of Blood Transfusion.

  15. 49 CFR 40.247 - What procedures does the BAT or STT follow after a screening test result?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What procedures does the BAT or STT follow after a... What procedures does the BAT or STT follow after a screening test result? (a) If the test result is an alcohol concentration of less than 0.02, as the BAT or STT, you must do the following: (1) Sign and date...

  16. 49 CFR 40.247 - What procedures does the BAT or STT follow after a screening test result?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What procedures does the BAT or STT follow after a... What procedures does the BAT or STT follow after a screening test result? (a) If the test result is an alcohol concentration of less than 0.02, as the BAT or STT, you must do the following: (1) Sign and date...

  17. 49 CFR 40.247 - What procedures does the BAT or STT follow after a screening test result?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What procedures does the BAT or STT follow after a... What procedures does the BAT or STT follow after a screening test result? (a) If the test result is an alcohol concentration of less than 0.02, as the BAT or STT, you must do the following: (1) Sign and date...

  18. 49 CFR 40.247 - What procedures does the BAT or STT follow after a screening test result?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What procedures does the BAT or STT follow after a... What procedures does the BAT or STT follow after a screening test result? (a) If the test result is an alcohol concentration of less than 0.02, as the BAT or STT, you must do the following: (1) Sign and date...

  19. 49 CFR 40.247 - What procedures does the BAT or STT follow after a screening test result?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What procedures does the BAT or STT follow after a... What procedures does the BAT or STT follow after a screening test result? (a) If the test result is an alcohol concentration of less than 0.02, as the BAT or STT, you must do the following: (1) Sign and date...

  20. Detection of CIN by naked eye visualization after application of acetic acid.

    PubMed

    Londhe, M; George, S S; Seshadri, L

    1997-06-01

    A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.

  1. Screening for cervical cancer among HIV-positive and HIV-negative women in Cameroon using simultaneous co-testing with careHPV DNA testing and visual inspection enhanced by digital cervicography: Findings of initial screening and one-year follow-up.

    PubMed

    Cholli, Preetam; Bradford, Leslie; Manga, Simon; Nulah, Kathleen; Kiyang, Edith; Manjuh, Florence; DeGregorio, Geneva; Ogembo, Rebecca K; Orock, Enow; Liu, Yuxin; Wamai, Richard G; Sheldon, Lisa Kennedy; Gona, Philimon N; Sando, Zacharie; Welty, Thomas; Welty, Edith; Ogembo, Javier Gordon

    2018-01-01

    The World Health Organization (WHO)'s cervical cancer screening guidelines for limited-resource settings recommend sequential screening followed by same-day treatment under a "screen-and-treat" approach. We aimed to (1) assess feasibility and clinical outcomes of screening HIV-positive and HIV-negative Cameroonian women by pairing visual inspection with acetic acid and Lugol's iodine enhanced by digital cervicography (VIA/VILI-DC) with careHPV, a high-risk human papillomavirus (HR-HPV) nucleic acid test designed for low-resource settings; and (2) determine persistence of HR-HPV infection after one-year follow-up to inform optimal screening, treatment, and follow-up algorithms. We co-tested 913 previously unscreened women aged ≥30years and applied WHO-recommended treatment for all VIA/VILI-DC-positive women. Baseline prevalence of HR-HPV and HIV were 24% and 42%, respectively. On initial screen, 44 (5%) women were VIA/VILI-DC-positive, of whom 22 had HR-HPV infection, indicating 50% of women screened false-positive and would have been triaged for unnecessary same-day treatment. VIA/VILI-DC-positive women with HIV infection were three times more likely to be HR-HPV-positive than HIV-negative women (65% vs. 20%). All women positive for either VIA/VILI-DC or HR-HPV (n=245) were invited for repeat co-testing after one year, of which 136 (56%) returned for follow-up. Of 122 women who were HR-HPV-positive on initial screen, 60 (49%) re-tested negative, of whom 6 had received treatment after initial screen, indicating that 44% of initially HR-HPV-positive women spontaneously cleared infection after one year without treatment. Women with HIV were more likely to remain HR-HPV-positive on follow-up than HIV-negative women (61% vs. 22%, p<0.001). Treatment was offered to all VIA/VILI-DC positive women on initial screen, and to all women screening VIA/VILI-DC or HR-HPV positive on follow-up. We found careHPV co-testing with VIA/VILI-DC to be feasible and valuable in identifying false-positives, but careHPV screening-to-result time was too long to inform same-day treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Screening for chronic obstructive pulmonary disease using spirometry: U.S. Preventive Services Task Force recommendation statement.

    PubMed

    2008-04-01

    New U.S. Preventive Services Task Force (USPSTF) recommendation about screening for chronic obstructive pulmonary disease (COPD) using spirometry. The USPSTF weighed the benefits (prevention of > or =1 exacerbation and improvement in respiratory-related health status measures) and harms (time and effort required by both patients and the health care system, false-positive screening tests, and adverse effects of subsequent unnecessary therapy) of COPD screening identified in the accompanying review of the evidence. The USPSTF did not consider the financial costs of spirometry testing or COPD therapies. Do not screen adults for COPD using spirometry. (Grade D recommendation).

  3. Screening for acute HIV infection in South Africa: finding acute and chronic disease

    PubMed Central

    Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.

    2010-01-01

    Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336

  4. Expert opinion on best practice guidelines and competency framework for visual screening in children.

    PubMed

    Lança, Carla

    2013-09-01

    Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.

  5. Comparison of the Modified-Hodge test, Carba NP test, and carbapenem inactivation method as screening methods for carbapenemase-producing Enterobacteriaceae.

    PubMed

    Yamada, Kageto; Kashiwa, Machiko; Arai, Katsumi; Nagano, Noriyuki; Saito, Ryoichi

    2016-09-01

    We compared three screening methods for carbapenemase-producing Enterobacteriaceae. While the Modified-Hodge test and Carba NP test produced false-negative results for OXA-48-like and mucoid NDM producers, the carbapenem inactivation method (CIM) showed positive results for these isolates. Although the CIM required cultivation time, it is well suited for general clinical laboratories. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Use of Breast Cancer Screening and Its Association with Later Use of Preventive Services among Medicare Beneficiaries.

    PubMed

    Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda

    2018-06-05

    Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.

  7. Test Performance and Test-Retest Reliability of the Vestibular/Ocular Motor Screening and King-Devick Test in Adolescent Athletes During a Competitive Sport Season.

    PubMed

    Worts, Phillip R; Schatz, Philip; Burkhart, Scott O

    2018-05-01

    The Vestibular/Ocular Motor Screening (VOMS) and King-Devick (K-D) test are tools designed to assess ocular or vestibular function after a sport-related concussion. To determine the test-retest reliability and rate of false-positive results of the VOMS and K-D test in a healthy athlete sample. Cohort study (diagnosis); Level of evidence, 2. Forty-five healthy high school student-athletes (mean age, 16.11 ± 1.43 years) completed self-reported demographics and medical history and were administered the VOMS and K-D test during rest on day 1 (baseline). The VOMS and K-D test were administered again once during rest (prepractice) and once within 5 minutes of removal from sport practice on day 2 (removal). The Borg rating of perceived exertion scale was administered at removal. Intraclass correlation coefficients were used to determine test-retest reliability on the K-D test and the average near point of convergence (NPC) distance on the VOMS. Level of agreement was used to examine VOMS symptom provocation over the 3 administration times. Multivariate base rates were used to determine the rate of false-positive results when simultaneously considering multiple clinical cutoffs. Test-retest reliability of total time on the K-D test (0.91 [95% CI, 0.86-0.95]) and NPC distance (0.91 [95% CI, 0.85-0.95]) was high across the 3 administration times. Level of agreement ranged from 48.9% to 88.9% across all 3 times for the VOMS items. Using established clinical cutoffs, false-positive results occurred in 2% of the sample using the VOMS at removal and 36% using the K-D test. The VOMS displayed a false-positive rate of 2% in this high school student-athlete cohort. The K-D test's false-positive rate was 36% while maintaining a high level of test-retest reliability (0.91). Results from this study support future investigation of VOMS administration in an acutely injured high school athletic sample. Going forward, the VOMS may be more stable than other neurological and symptom report screening measures and less vulnerable to false-positive results than the K-D test.

  8. Relevance of cutoff on a 4th generation ELISA performance in the false positive rate during HIV diagnostic in a low HIV prevalence setting.

    PubMed

    Chacón, Lucía; Mateos, María Luisa; Holguín, África

    2017-07-01

    Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Screening for colorectal cancer.

    PubMed

    Ross, C C

    1988-12-01

    Efforts to decrease the number of deaths from colorectal cancer have focused on screening techniques, since no etiologic agent has been identified. Current screening regimens are designed to detect colorectal cancer in a large population in a cost-efficient manner and to minimize the risks associated with work-ups for false-positive tests. A two-part screening questionnaire for colorectal cancer helps identify patients who are at moderate risk for this cancer.

  10. False-Positive Tuberculin Skin Test Results Among Low-Risk Healthcare Workers Following Implementation of Fifty-Dose Vials of Purified Protein Derivative.

    PubMed

    Collins, Jeffrey M; Hunter, Mary; Gordon, Wanda; Kempker, Russell R; Blumberg, Henry M; Ray, Susan M

    2018-06-01

    Following large declines in tuberculosis transmission the United States, large-scale screening programs targeting low-risk healthcare workers are increasingly a source of false-positive results. We report a large cluster of presumed false-positive tuberculin skin test results in healthcare workers following a change to 50-dose vials of Tubersol tuberculin.Infect Control Hosp Epidemiol 2018;39:750-752.

  11. Replacing Alpha-Fetoprotein With Alpha-Fetoprotein-L3 Increases the Sensitivity of Prenatal Screening for Trisomy 21.

    PubMed

    Huai, Lei; Leng, Jianhang; Ma, Shenglin; Huang, Fang; Shen, Junya; Ding, Yu

    This study aimed to investigate the serum concentration of alpha-fetoprotein (AFP)-L3 in midterm pregnancies and its potential application in prenatal trisomy screening. The serum samples from 27 women with trisomy 21 fetuses and 800 women with normal fetuses were examined to measure the concentrations of AFP, AFP-L3, human chorionic gonadotropin (hCG), unconjugated estriol (uE3), and inhibin-A. The screening results of various tests consisting of these markers were analyzed. In normal pregnancies within 15-20 weeks of gestation, the medians of serum AFP-L3 were 4.63, 5.70, 5.78, 6.58, 7.03, and 7.25 pg/mL. The median of AFP-L3 MoM in the trisomy 21 group was 0.46, which was significantly lower than the value of 1 in the normal group (P < 0.05). When using a cutoff value of 1/270, the sensitivity of the triple marker test (AFP, hCG, uE3) was improved from 74% to 81% by replacing AFP with AFP-L3, with the false-positive rate slightly increased from 5.4% to 6.8%. Similarly, the sensitivity of the quad marker test (AFP, hCG, uE3, inhibin-A) was improved from 81% to 89% by replacing AFP with AFP-L3, with the false-positive rate slightly increased from 4.6% to 5.6%. Serum AFP-L3 concentration increases along with more weeks of gestation in the midterm pregnancies. Trisomy 21 screening tests with AFP replaced by AFP-L3 have higher sensitivities at the expense of slightly increased false-positive rates. This improvement in screening may help to better prepare the parents and caregivers for the special needs of newborns with trisomy 21.

  12. First trimester combined test for Down syndrome screening in unselected pregnancies - a report of a 13-year experience.

    PubMed

    Lee, Fa-Kung; Chen, Li-Ching; Cheong, Mei-Leng; Chou, Ching-Yu; Tsai, Ming-Song

    2013-12-01

    To analyze the performance of the first trimester Down syndrome screening in a single medical center in Northern Taiwan. From April 1999 to June 2012, a total of 25,104 pregnant women at gestational age of 10 weeks to 13 weeks 6 days received first trimester "combined test" for Down syndrome screening. The test combines the ultrasound scan of nuchal translucency thickness and maternal biochemical serum levels of pregnancy-associated plasma protein A (PAPP-A) and free beta-human chorionic gonadotropin (β-hCG). A positive screen was defined as an estimated Down syndrome risk ≥ 1/270, and either chorionic villous sampling or amniocentesis was performed for fetal chromosomal analyses. Seventy-eight of the 25,104 pregnancies were proven to have fetal chromosome anomalies. The detection rates for trisomy 21, trisomy 18, Turner syndrome, and other chromosome anomalies were 87.5% (21/24), 69.2% (9/13), 81.8% (9/11), and 60% (18/30), respectively, with a false positive rate (FPR) of 5.4% (1353/25,026). Further evaluation of the detection rates for trisomy 21, by gestational age at 11, 12, and 13 weeks, were 92.3%, 87.5%, and 66.7%, respectively. The first trimester combined test is an effective screening tool for Down syndrome detection with an acceptable low false positive rate. The best timing of screening will be between 11 and 12 weeks' gestation. Copyright © 2013. Published by Elsevier B.V.

  13. Serologic Screening for Genital Herpes: An Updated Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Feltner, Cynthia; Grodensky, Catherine; Ebel, Charles; Middleton, Jennifer C; Harris, Russell P; Ashok, Mahima; Jonas, Daniel E

    2016-12-20

    Genital herpes simplex virus (HSV) infection is a prevalent sexually transmitted infection. Vertical transmission of HSV can lead to fetal morbidity and mortality. To assess the evidence on serologic screening and preventive interventions for genital HSV infection in asymptomatic adults and adolescents to support the US Preventive Services Task Force for an updated recommendation statement. MEDLINE, Cochrane Library, EMBASE, and trial registries through March 31, 2016. Surveillance for new evidence in targeted publications was conducted through October 31, 2016. English-language randomized clinical trials (RCTs) comparing screening with no screening in persons without past or current symptoms of genital herpes; studies evaluating accuracy and harms of serologic screening tests for HSV-2; RCTs assessing preventive interventions in asymptomatic persons seropositive for HSV-2. Dual review of abstracts, full-text articles, and study quality; pooled sensitivities and specificities of screening tests using a hierarchical summary receiver operating characteristic curve analysis when at least 3 similar studies were available. Accuracy of screening tests, benefits of screening, harms of screening, reduction in genital herpes outbreaks. A total of 17 studies (n = 9736 participants; range, 24-3290) in 19 publications were included. No RCTs compared screening with no screening. Most studies of the accuracy of screening tests were from populations with high HSV-2 prevalence (greater than 40% based on Western blot). Pooled estimates of sensitivity and specificity of the most commonly used test at the manufacturer's cutpoint were 99% (95% CI, 97%-100%) and 81% (95% CI, 68%-90%), respectively (10 studies; n = 6537). At higher cutpoints, pooled estimates were 95% (95% CI, 91%-97%) and 89% (95% CI, 82%-93%), respectively (7 studies; n = 5516). Use of this test at the manufacturer's cutpoint in a population of 100 000 with a prevalence of HSV-2 of 16% (the seroprevalence in US adults with unknown symptom status) would result in 15 840 true-positive results and 15 960 false-positive results (positive predictive value, 50%). Serologic screening for genital herpes was associated with psychosocial harms, including distress and anxiety related to positive test results. Four RCTs compared preventive medications with placebo, 2 in nonpregnant asymptomatic adults who were HSV-2 seropositive and 2 in HSV-2-serodiscordant couples. Results in both populations were heterogeneous and inconsistent. Serologic screening for genital herpes is associated with a high rate of false-positive test results and potential psychosocial harms. Evidence from RCTs does not establish whether preventive antiviral medication for asymptomatic HSV-2 infection has benefit.

  14. Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.

    PubMed

    Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M

    1997-06-01

    To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of screening. Advantages of the IRT/DNA protocol over IRT analysis include improved positive predictive value, reduction of false-positive infants, and more rapid diagnosis with elimination of recall specimens.

  15. Screening options for Down syndrome: how women choose in real clinical setting.

    PubMed

    Lo, T K; Lai, F K; Leung, W C; Lau, W L; Ng, L S; Wong, W C; Tam, S S; Yee, Y C; Choi, H; Lam, H S W; Sham, A S Y; Tang, L C H; Chin, R K H

    2009-09-01

    To study pregnant women's preference among various screening options for Down syndrome (DS) in routine clinical setting, and its potential association with women's demographic characteristics. Women aged 35 years and older carrying singleton pregnancy were offered a variety of screening tests for DS before 14 weeks of gestation. Their preference was confirmed by the test they actually underwent. The association between women's choice of test and a number of demographic characteristics was studied using multinomial regression. Among 1967 eligible women, 619 opted for first-trimester screening test (FTS), 924 for partial integrated test (PIT), and 424 for full integrated test (FIT). Nulliparous women and working mothers were more likely to choose FTS and FIT. Women with history of subfertility were more likely to choose FIT. Women with family history of chromosomal abnormalities were more likely to choose FTS. The choice of screening test could be predicted for 49.9% of women using four demographic characteristics. Among older women of predominantly Chinese ethnicity, integrated test is a favorite alternative to FTS. Their choice of DS screening test can be predicted by their obstetric and socioeconomic characteristics. Many women show willingness to pay for a test with a lower false-positive rate.

  16. Maternal Plasma DNA and RNA Sequencing for Prenatal Testing.

    PubMed

    Tamminga, Saskia; van Maarle, Merel; Henneman, Lidewij; Oudejans, Cees B M; Cornel, Martina C; Sistermans, Erik A

    2016-01-01

    Cell-free DNA (cfDNA) testing has recently become indispensable in diagnostic testing and screening. In the prenatal setting, this type of testing is often called noninvasive prenatal testing (NIPT). With a number of techniques, using either next-generation sequencing or single nucleotide polymorphism-based approaches, fetal cfDNA in maternal plasma can be analyzed to screen for rhesus D genotype, common chromosomal aneuploidies, and increasingly for testing other conditions, including monogenic disorders. With regard to screening for common aneuploidies, challenges arise when implementing NIPT in current prenatal settings. Depending on the method used (targeted or nontargeted), chromosomal anomalies other than trisomy 21, 18, or 13 can be detected, either of fetal or maternal origin, also referred to as unsolicited or incidental findings. For various biological reasons, there is a small chance of having either a false-positive or false-negative NIPT result, or no result, also referred to as a "no-call." Both pre- and posttest counseling for NIPT should include discussing potential discrepancies. Since NIPT remains a screening test, a positive NIPT result should be confirmed by invasive diagnostic testing (either by chorionic villus biopsy or by amniocentesis). As the scope of NIPT is widening, professional guidelines need to discuss the ethics of what to offer and how to offer. In this review, we discuss the current biochemical, clinical, and ethical challenges of cfDNA testing in the prenatal setting and its future perspectives including novel applications that target RNA instead of DNA. © 2016 Elsevier Inc. All rights reserved.

  17. Measuring the psychosocial consequences of screening

    PubMed Central

    Brodersen, John; McKenna, Stephen P; Doward, Lynda C; Thorsen, Hanne

    2007-01-01

    The last three decades have seen a dramatic rise in the implementation of screening programmes for cancer in industrialised countries. However, in contrast to screening for infectious diseases, most cancer screening programmes only have the potential to reduce mortality; they cannot lower the incidence of cancer in a population. In fact, most cancer screening programmes have been shown to increase the incidence of the disease as a consequence of over-diagnosis. A further dilemma of cancer screening programmes is that they do not distinguish between healthy people and those with disease. Rather, they identify a continuum of disease severity. Consequently, many healthy people who have abnormal screening tests are wrongly diagnosed. Indeed, studies have demonstrated that for each screening-prevented death from cancer, at least 200 false-positive results are given. Therefore, screening has the potential to be harmful as well as beneficial. The psychosocial consequences of false-positive screening results cannot be determined by diagnostic tests or by other technical means. Instead, patient reported outcome measures must be employed. To measure the outcomes of screening accurately and comprehensively patient reported outcome measures have to capture; the nature and extent of the psychosocial consequences and how these change over time. The outcome measures used must have high content validity and their psychometric properties should be determined prior to their use in the specific population. In particular it is important to establish unidimensionality, additivity and item ordering through the application of Item Response Theory. PMID:17210071

  18. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  19. Cost analysis of different cervical cancer screening strategies in Mexico.

    PubMed

    Beal, Christyn M; Salmerón, Jorge; Flores, Yvonne N; Torres, Leticia; Granados-García, Víctor; Dugan, Ellen; Lazcano-Ponce, Eduardo

    2014-01-01

    To compare the costs and number of undetected cases of four cervical cancer screening strategies (CCSS) in Mexico. We estimated the costs and outcomes of the following CCSS: a) conventional Papanicolaou smear (Pap) alone; b) high-risk human papilloma virus testing (HR-HPV) as primary screening with Pap as reflex triage; c) HR-HPV as primary screening with HPV-16/18 typing, liquid-based cytology (LBC) and immunostaining for p16/Ki67 testing as reflex triage, and d) co-testing with HR-HPV and LBC with HPV-16/18 typing and immunostaining for p16/Ki67 as reflex triage. The outcome of interest was high-grade cervical lesions or cervical cancer. HR-HPV testing, HPV typing, LBC testing and immunostaining is the best alternative because it is the least expensive option with an acceptable number of missed cases. The opportunity costs of a poor quality CCSS is many false negatives. Combining multiple tests may be a more cost-effective way to screen for cervical cancer in Mexico.

  20. Cross-Reactivity of Pantoprazole with Three Commercial Cannabinoids Immunoassays in Urine.

    PubMed

    Gomila, Isabel; Barceló, Bernardino; Rosell, Antonio; Avella, Sonia; Sahuquillo, Laura; Dastis, Macarena

    2017-11-01

    Pantoprazole is a frequently prescribed proton pump inhibitor (PPI) commonly utilized in the management of gastrointestinal symptoms. Few substances have proved to cause a false-positive cannabinoid urine screen. However, a case of false-positive urine cannabinoid screen in a patient who received a pantoprazole dose has been recently published. The purpose of this study was to determine the potential cross-reactivity of pantoprazole in the cannabinoid immunoassays: Alere Triage® TOX Drug Screen, KIMS® Cannabinoids II and DRI® Cannabinoids Assay. Drug-free urine to which pantoprazole was added up to 12,000 μg/mL produced negative results in the DRI® Cannabinoids and KIMS® Cannabinoids II. Alere Triage® TOX Drug Screen assay gave positive results at pantoprazole concentrations higher than 1,000 μg/mL. Urine samples from 8 pediatric patients were collected at the beginning of their pantoprazole treatment. Alere Triage® TOX Drug Screen assay produced positive test results in all patient samples and KIMS® Cannabinoids II immunoassay produced positive test results in one patient sample. None patient sample gave a false-positive result when analyzed by the DRI® Cannabinoids Assay. Our findings demonstrate that some cannabinoids immunoassays are susceptible to cross-reaction errors resulting from the presence in urine of pantoprazole and the resulting metabolism of the parent drug. Clinicians should be aware of the possibility of false-positive results for cannabinoids after a pantoprazole treatment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Human Papillomavirus Assays and Cytology in Primary Cervical Screening of Women Aged 30 Years and Above

    PubMed Central

    Rebolj, Matejka; Bonde, Jesper; Preisler, Sarah; Ejegod, Ditte; Rygaard, Carsten; Lynge, Elsebeth

    2016-01-01

    In women aged ≥30 years, Human Papillomavirus testing will replace cytology for primary cervical screening. We compared Hybrid Capture 2 (HC2), cobas, CLART, and APTIMA HPV assays with cytology on 2869 SurePath samples from women undergoing routine screening at 30–65 years in Copenhagen, Denmark. Women with cytological abnormalities were managed according to routine recommendations, with 92% completeness. Those with cytology-normal/HPV-positive samples (on any of the four assays) were invited for repeated cytology and HPV testing in 1.5 year, and 58% had additional testing. HPV testing detected more ≥CIN3 than cytology (HC2: 35, cobas, CLART: 37, APTIMA: 34, cytology: 31), although statistically the differences were not significant. Cobas and CLART detected significantly more ≥CIN2 than cytology (cobas, CLART: 49, cytology: 39). The proportion of women with false-positive test results (positive test results without ≥CIN3) varied between 3.3% with cytology and 14.9% with cobas. All HPV assays led to significantly more false-positive tests, whereas compared to HC2 cobas and CLART were associated with a significantly higher and APTIMA with a significantly lower proportion. Detection of CIN1 was particularly increased for the three DNA assays. With APTIMA combined with cytological triage, about 20% more women were referred for colposcopy than with cytology screening. With the three DNA assays, the increase was ≥50%. The number of women with repeated testing was twice as high with APTIMA and almost five times as high with cobas compared to cytology. To our knowledge, Horizon was the only study set in routine practice that compared more than two HPV assays in the same women while also ascertaining the histological status of women with normal cytology/HPV-positive test results. HPV-based screening of Danish women aged 30–65 detected more high-grade CIN but decreased the screening specificity, and increased the demand for additional testing. PMID:26789267

  2. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  3. False negative fecal occult blood test may be associated with increased mortality from colorectal cancer.

    PubMed

    Half, Elizabeth E; Mlynarsky, Liat; Naftali, Timna; Benjaminov, Fabiana; Konikoff, Fred M

    2013-09-01

    Fecal Occult Blood Test (FOBT) is an accepted screening test for colorectal cancer (CRC). It has been shown to decrease mortality by up to 30%. The outcome of screening failures has not been adequately studied. The purpose of this study was to assess the outcome of patients who were diagnosed with CRC after a false negative FOBT. We identified all consecutive CRCs from pathology reports between 2005 and 2010. Patients were divided according to their FOBT result. Those who became positive were compared to patients who remained negative. Altogether 401 CRCs were identified. Of those, 202 never performed a FOBT. At least one negative FOBT was performed by 133 individuals (67%). Of these, 76 remained negative (false negatives, FN) and 57 became positive (positive conversion, PC, controls). The prevalence of metastatic disease was threefold higher among the FNs as compared to the PC group (16 [22.2%] vs. 4 [7.5%], P=0.022). All-cause mortality was also significantly higher among FNs versus PCs (24 [31.6%] vs. 5 [8.8%], P=0.001); in Cox regression analysis of survival (covariates: FNs vs. PC, gender, age, medications and co-morbidities) FNs had increased mortality compared to the PC (HR 2.929, P=0.033, CI 95% 1.092-7.858). No statistically significant difference was found regarding all primary end points when comparing the FN and the "No test" group. These data disclose a particular risk of FOBT as a screening test. A subgroup of patients with "false" negative tests may have increased morbidity and mortality. Efforts should be made to recognize and characterize this high-risk group.

  4. Evaluation of the black light test for screening aflatoxin-contaminated maize in the Brazilian food industry.

    PubMed

    Gloria, E M; Fonseca, H; Calori-Domingues, M A; Souza, I M

    1998-01-01

    The results of the black light test for aflatoxin-contaminated maize carried out in a large food factory in the State of São Paulo was evaluated against bi-directional thin layer chromatography (TLC) analysis for 286 samples of maize. All 286 samples were accepted by the black light test (< 7 fluorescent points), however, the results from TLC analysis showed that 96 samples were contaminated and 14 showed aflatoxin B1 contamination levels higher than 20 micrograms/kg. There were 14 false negative results and no false positives and out of the 14 samples, six did not show visible fluorescent points. If the rejection criterion of one or more fluorescent points were applied, the six samples would be accepted by the black light test. But, in this case, 95 samples would be rejected and 87 results would be false positives because they did not have contamination levels over 20 micrograms/kg which is the acceptance limit of the black light test. The results indicate that the black light test, as utilized by this factory, was not able to indicate lots with possible contamination and the black light test, as recommended in the literature, would produce a high number of false positives. It is necessary to make more studies on the use of black light as a screening test for possible aflatoxin B1-contaminated maize.

  5. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  6. Newborn hearing screening update for midwifery practice.

    PubMed

    Narrigan, D

    2000-01-01

    Neonatal identification of congenital hearing impairment allows interventions during the first 3 years, the critical period for language and speech development. Two recently developed biophysical testing methods offer simple, accurate, and relatively inexpensive means to identify the one to three in 1,000 healthy newborns with hearing loss. Universal screening for auditory system integrity is advocated, because almost half of all newborns with hearing impairment have no risk factors associated with this impairment. Critics of universal screening cite the high rate of false positive tests (up to 7%), which increases program costs from follow-up and re-testing large numbers of infants to ensure identifying the few affected infants. As of early 2000, 24 states had introduced some type of auditory screening program, and the U.S. Congress had passed legislation with appropriations mandating state-based auditory screening for all newborns. Midwives practicing in states already mandating biophysical screening need to comply with their local requirements; those in other states may voluntarily incorporate new auditory test methods into practice.

  7. 49 CFR 40.211 - Who conducts DOT alcohol tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Who conducts DOT alcohol tests? 40.211 Section 40... DRUG AND ALCOHOL TESTING PROGRAMS Alcohol Testing Personnel § 40.211 Who conducts DOT alcohol tests? (a) Screening test technicians (STTs) and breath alcohol technicians (BATs) meeting their respective...

  8. 49 CFR 40.211 - Who conducts DOT alcohol tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Who conducts DOT alcohol tests? 40.211 Section 40... DRUG AND ALCOHOL TESTING PROGRAMS Alcohol Testing Personnel § 40.211 Who conducts DOT alcohol tests? (a) Screening test technicians (STTs) and breath alcohol technicians (BATs) meeting their respective...

  9. The psychological impact of a false-positive screening mammogram in Barcelona.

    PubMed

    Espasa, Rebecca; Murta-Nascimento, Cristiane; Bayés, Ramón; Sala, Maria; Casamitjana, Montserrat; Macià, Francesc; Castells, Xavier

    2012-12-01

    The purpose of this study was to ascertain the psychological impact of mammographic screening for women who receive negative results and for those who need additional non-invasive and invasive complementary investigations to exclude breast cancer (false positives). One hundred fifty women who attended a breast cancer screening programme in Barcelona, aged 50-69 years, were included in this study: 50 with negative results and 100 with false positive mammograms (50 underwent non-invasive and 50 underwent invasive complementary investigations). Participants worried little until they underwent mammography, but worries increased when a telephone call notified the women of the need for further testing. A substantial proportion of women requiring further assessment reported that they were at least somewhat worried about having breast cancer throughout the screening process (P < 0.0001). Nevertheless, levels of anxiety and depression, measured by the Hospital Anxiety and Depression Scale, showed no statistically significant differences among the three groups. In conclusion, although the women showed no psychological morbidity, there is a substantial psychological response in those with an abnormal screening mammogram.

  10. Screening tests: a review with examples

    PubMed Central

    Niebo, Ron; Utell, Mark J.

    2014-01-01

    Screening tests are widely used in medicine to assess the likelihood that members of a defined population have a particular disease. This article presents an overview of such tests including the definitions of key technical (sensitivity and specificity) and population characteristics necessary to assess the benefits and limitations of such tests. Several examples are used to illustrate calculations, including the characteristics of low dose computed tomography as a lung cancer screen, choice of an optimal PSA cutoff and selection of the population to undergo mammography. The importance of careful consideration of the consequences of both false positives and negatives is highlighted. Receiver operating characteristic curves are explained as is the need to carefully select the population group to be tested. PMID:25264934

  11. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  12. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  13. A Workflow for Identifying Metabolically Active Chemicals to Complement in vitro Toxicity Screening

    EPA Science Inventory

    The new paradigm of toxicity testing approaches involves rapid screening of thousands of chemicals across hundreds of biological targets through use of in vitro assays. Such assays may lead to false negatives when the complex metabolic processes that render a chemical bioactive i...

  14. Newborn screening: a review of history, recent advancements, and future perspectives in the era of next generation sequencing.

    PubMed

    Almannai, Mohammed; Marom, Ronit; Sutton, V Reid

    2016-12-01

    The purpose of this review is to summarize the development and recent advancements of newborn screening. Early initiation of medical care has modified the outcome for many disorders that were previously associated with high morbidity (such as cystic fibrosis, primary immune deficiencies, and inborn errors of metabolism) or with significant neurodevelopmental disabilities (such as phenylketonuria and congenital hypothyroidism). The new era of mass spectrometry and next generation sequencing enables the expansion of the newborn screen panel, and will help to address technical issues such as turnaround time, and decreasing false-positive and false-negative rates for the testing. The newborn screening program is a successful public health initiative that facilitates early diagnosis of treatable disorders to reduce long-term morbidity and mortality.

  15. Benefits, harms, and costs for breast cancer screening after US implementation of digital mammography.

    PubMed

    Stout, Natasha K; Lee, Sandra J; Schechter, Clyde B; Kerlikowske, Karla; Alagoz, Oguzhan; Berry, Donald; Buist, Diana S M; Cevik, Mucahit; Chisholm, Gary; de Koning, Harry J; Huang, Hui; Hubbard, Rebecca A; Miglioretti, Diana L; Munsell, Mark F; Trentham-Dietz, Amy; van Ravesteyn, Nicolien T; Tosteson, Anna N A; Mandelblatt, Jeanne S

    2014-06-01

    Compared with film, digital mammography has superior sensitivity but lower specificity for women aged 40 to 49 years and women with dense breasts. Digital has replaced film in virtually all US facilities, but overall population health and cost from use of this technology are unclear. Using five independent models, we compared digital screening strategies starting at age 40 or 50 years applied annually, biennially, or based on density with biennial film screening from ages 50 to 74 years and with no screening. Common data elements included cancer incidence and test performance, both modified by breast density. Lifetime outcomes included mortality, quality-adjusted life-years, and screening and treatment costs. For every 1000 women screened biennially from age 50 to 74 years, switching to digital from film yielded a median within-model improvement of 2 life-years, 0.27 additional deaths averted, 220 additional false-positive results, and $0.35 million more in costs. For an individual woman, this translates to a health gain of 0.73 days. Extending biennial digital screening to women ages 40 to 49 years was cost-effective, although results were sensitive to quality-of-life decrements related to screening and false positives. Targeting annual screening by density yielded similar outcomes to targeting by age. Annual screening approaches could increase costs to $5.26 million per 1000 women, in part because of higher numbers of screens and false positives, and were not efficient or cost-effective. The transition to digital breast cancer screening in the United States increased total costs for small added health benefits. The value of digital mammography screening among women aged 40 to 49 years depends on women's preferences regarding false positives. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Urine drug screens: Considerations for the psychiatric pharmacist

    PubMed Central

    Hale, Genevieve M.; Ross, Clint

    2016-01-01

    Introduction: Proper psychiatric evaluation of patients necessitates that the clinician be vigilant in ruling out secondary causes of symptoms, such as substance-induced symptoms. Immunoassay-type urine drug screens (UDSs) offer clinicians rapid drug screen results, ease of use, and inexpensive cost. Unfortunately, these screens are not without their limitations. This review aims to outline the nuances and limitations of immunoassay UDSs and to provide the clinician with information that facilitates more accurate interpretation of UDS results. Specifically, false positive results associated with psychiatric medications and the availability and methods for acquisition of commercialized UDS masking agents will be reviewed. Methods: A literature review was conducted to identify false positive UDSs associated with psychiatric medications. References for each article identified were also reviewed. Additionally, a Google® search was conducted to identify commercially available preparations used to mask UDS results and the methods of acquisition of these products. Results: A total of 14 articles were identified using PubMed. No articles for mood stabilizing agents were identified. Entering the phrase how to pass a drug test into Google® search yielded about 12.6 million results, and select references were reviewed based on relevance and user reviews. Discussion: Several psychiatric medications are documented as potential sources of false positive UDSs. Additionally, several agents are available for consumer purchase that may result in false negative UDSs. The clinician must be vigilant in interpreting immunoassay UDS results and should utilize more advanced forms of testing as clinically appropriate.

  17. Comparison of one-tier and two-tier newborn screening metrics for congenital adrenal hyperplasia.

    PubMed

    Sarafoglou, Kyriakie; Banks, Kathryn; Gaviglio, Amy; Hietala, Amy; McCann, Mark; Thomas, William

    2012-11-01

    Newborn screening (NBS) for the classic forms of congenital adrenal hyperplasia (CAH) is mandated in all states in the United States. Compared with other NBS disorders, the false-positive rate (FPR) of CAH screening remains high and has not been significantly improved by adjusting 17α-hydroxyprogesterone cutoff values for birth weight and/or gestational age. Minnesota was the first state to initiate, and only 1 of 4 states currently performing, second-tier steroid profiling for CAH. False-negative rates (FNRs) for CAH are not well known. This is a population-based study of all Minnesota infants (769,834) born 1999-2009, grouped by screening protocol (one-tier with repeat screen, January 1999 to May 2004; two-tier with second-tier steroid profiling, June 2004 to December 2009). FPR, FNR, and positive predictive value (PPV) were calculated per infant, rather than per sample, and compared between protocols. Overall, 15 false-negatives (4 salt-wasting, 11 simple-virilizing) and 45 true-positives were identified from 1999 to 2009. With two-tier screening, FNR was 32%, FPR increased to 0.065%, and PPV decreased to 8%, but these changes were not statistically significant. Second-tier steroid profiling obviated repeat screens of borderline results (355 per year average). In comparing the 2 screening protocols, the FPR of CAH NBS remains high, the PPV remains low, and false-negatives occur more frequently than has been reported. Physicians should be cautioned that a negative NBS does not necessarily rule out classic CAH; therefore, any patient for whom there is clinical concern for CAH should receive immediate diagnostic testing.

  18. Expanded newborn screening by mass spectrometry: New tests, future perspectives.

    PubMed

    Ombrone, Daniela; Giocaliere, Elisa; Forni, Giulia; Malvagia, Sabrina; la Marca, Giancarlo

    2016-01-01

    Tandem mass spectrometry (MS/MS) has become a leading technology used in clinical chemistry and has shown to be particularly sensitive and specific when used in newborn screening (NBS) tests. The success of tandem mass spectrometry is due to important advances in hardware, software and clinical applications during the last 25 years. MS/MS permits a very rapid measurement of many metabolites in different biological specimens by using filter paper spots or directly on biological fluids. Its use in NBS give us the chance to identify possible treatable metabolic disorders even when asymptomatic and the benefits gained by this type of screening is now recognized worldwide. Today the use of MS/MS for second-tier tests and confirmatory testing is promising especially in the early detection of new disorders such as some lysosomal storage disorders, ADA and PNP SCIDs, X-adrenoleucodistrophy (X-ALD), Wilson disease, guanidinoacetate methyltransferase deficiency (GAMT), and Duchenne muscular dystrophy. The new challenge for the future will be reducing the false positive rate by using second-tier tests, avoiding false negative results by using new specific biomarkers and introducing new treatable disorders in NBS programs. © 2015 Wiley Periodicals, Inc.

  19. Overnight dexamethasone suppression test: a reliable screen for Cushing's syndrome in the obese.

    PubMed

    Ness-Abramof, Rosane; Nabriski, Dan; Apovian, Caroline M; Niven, Mark; Weiss, Eliahu; Shapiro, Menachem S; Shenkman, Louis

    2002-12-01

    Reevaluation of the validity of the 1-mg overnight dexamethasone suppression test (ODST) as a screening test for Cushing's syndrome in obese patients. Eighty-six obese patients (body mass index, 30 to 53 kg/m(2)) that were referred to a general endocrine outpatient clinic for evaluation of simple obesity, diabetes mellitus, hypertension, polycystic ovary disease, or pituitary tumor. One milligram dexamethasone was administered orally at 11:00 PM, and serum cortisol levels were measured the following morning between 8:00 AM and 9:00 AM. Suppression of serum cortisol to <80 nM (3 micro g/dL) was chosen as the cut-off point for normal suppression. Patients with serum cortisol levels > or =80 nM were evaluated for Cushing's syndrome. Suppression of morning cortisol levels to <80 nM occurred in 79 of the 86 obese patients. Seven patients had serum cortisol levels higher than 80 nM; five were eventually diagnosed with Cushing's syndrome and two were considered false positive results in view of normal 24-hour free urinary cortisol and normal suppression on a low dose dexamethasone suppression test (0.5 mg of dexamethasone every 6 hours for 2 days). We found a false positive rate of 2.3% for the ODST using a cut-off serum cortisol of 80 nM. The ODST is a valid screening test for Cushing's syndrome in the obese population. The false positive rate was 2.3%, even when using a strict cut-off serum cortisol of 80 nM. Abnormal cortisol suppression in obese patients should be investigated and not be considered false positive results.

  20. 49 CFR 40.211 - Who conducts DOT alcohol tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Who conducts DOT alcohol tests? 40.211 Section 40.211 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Alcohol Testing Personnel § 40.211 Who conducts DOT alcohol tests? (a) Screening test technicians (STTs) and breat...

  1. Screening for skin cancer.

    PubMed

    Helfand, M; Mahon, S M; Eden, K B; Frame, P S; Orleans, C T

    2001-04-01

    Malignant melanoma is often lethal, and its incidence in the United States has increased rapidly over the past 2 decades. Nonmelanoma skin cancer is seldom lethal, but, if advanced, can cause severe disfigurement and morbidity. Early detection and treatment of melanoma might reduce mortality, while early detection and treatment of nonmelanoma skin cancer might prevent major disfigurement and to a lesser extent prevent mortality. Current recommendations from professional societies regarding screening for skin cancer vary. To examine published data on the effectiveness of routine screening for skin cancer by a primary care provider, as part of an assessment for the U.S. Preventive Services Task Force. We searched the MEDLINE database for papers published between 1994 and June 1999, using search terms for screening, physical examination, morbidity, and skin neoplasms. For information on accuracy of screening tests, we used the search terms sensitivity and specificity. We identified the most important studies from before 1994 from the Guide to Clinical Preventive Services, second edition, and from high-quality reviews. We used reference lists and expert recommendations to locate additional articles. Two reviewers independently reviewed a subset of 500 abstracts. Once consistency was established, the remainder were reviewed by one reviewer. We included studies if they contained data on yield of screening, screening tests, risk factors, risk assessment, effectiveness of early detection, or cost effectiveness. We abstracted the following descriptive information from full-text published studies of screening and recorded it in an electronic database: type of screening study, study design, setting, population, patient recruitment, screening test description, examiner, advertising targeted at high-risk groups or not targeted, reported risk factors of participants, and procedure for referrals. We also abstracted the yield of screening data including probabilities and numbers of referrals, types of suspected skin cancers, biopsies, confirmed skin cancers, and stages and thickness of skin cancers. For studies that reported test performance, we recorded the definition of a suspicious lesion, the "gold-standard" determination of disease, and the number of true positive, false positive, true negative, and false negative test results. When possible, positive predictive values, likelihood ratios, sensitivity, and specificity were recorded. No randomized or case-control studies have been done that demonstrate that routine screening for melanoma by primary care providers reduces morbidity or mortality. Basal cell carcinoma and squamous cell carcinoma are very common, but detection and treatment in the absence of formal screening are almost always curative. No controlled studies have shown that formal screening programs will improve this already high cure rate. While the efficacy of screening has not been established, the screening procedures themselves are noninvasive, and the follow-up test, skin biopsy, has low morbidity. Five studies from mass screening programs reported the accuracy of skin examination as a screening test. One of these, a prospective study, tracked patients with negative results to determine the number of patients with false-negative results. In this study, the sensitivity of screening for skin cancer was 94% and specificity was 98%. Several recent case-control studies confirm earlier evidence that risk of melanoma rises with the presence of atypical moles and/or many common moles. One well-done prospective study demonstrated that risk assessment by limited physical exam identified a relatively small (<10%) group of primary care patients for more thorough evaluation. The quality of the evidence addressing the accuracy of routine screening by primary care providers for early detection of melanoma or nonmelanoma skin cancer ranged from poor to fair. We found no studies that assessed the effectiveness of periodic skin examination by a clinician in reducing melanoma mortality. Both self-assessment of risk factors or clinician examination can classify a small proportion of patients as at highest risk for melanoma. Skin cancer screening, perhaps using a risk-assessment technique to identify high-risk patients who are seeing a physician for other reasons, merits additional study as a strategy to address the excess burden of disease in older adults.

  2. Clinical experience of laboratory follow-up with noninvasive prenatal testing using cell-free DNA and positive microdeletion results in 349 cases.

    PubMed

    Schwartz, S; Kohan, M; Pasion, R; Papenhausen, P R; Platt, L D

    2018-02-01

    Screening via noninvasive prenatal testing (NIPT) involving the analysis of cell-free DNA (cfDNA) from plasma has become readily available to screen for chromosomal and DNA aberrations through maternal blood. This report reviews a laboratory's experience with follow-up of positive NIPT screens for microdeletions. Patients that were screened positive by NIPT for a microdeletion involving 1p, 4p, 5p, 15q, or 22q who underwent diagnostic studies by either chorionic villus sampling or amniocentesis were evaluated. The overall positive predictive value for 349 patients was 9.2%. When a microdeletion was confirmed, 39.3% of the cases had additional abnormal microarray findings. Unrelated abnormal microarray findings were detected in 11.8% of the patients in whom the screen positive microdeletion was not confirmed. Stretches of homozygosity in the microdeletion were frequently associated with a false positive cfDNA microdeletion result. Overall, this report reveals that while cfDNA analysis will screen for microdeletions, the positive predictive value is low; in our series it is 9.2%. Therefore, the patient should be counseled accordingly. Confirmatory diagnostic microarray studies are imperative because of the high percentage of false positives and the frequent additional abnormalities not delineated by cfDNA analysis. © 2018 John Wiley & Sons, Ltd.

  3. Test set readings predict clinical performance to a limited extent: preliminary findings

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.

    2013-03-01

    Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.

  4. Evaluation of machine learning algorithms for improved risk assessment for Down's syndrome.

    PubMed

    Koivu, Aki; Korpimäki, Teemu; Kivelä, Petri; Pahikkala, Tapio; Sairanen, Mikko

    2018-05-04

    Prenatal screening generates a great amount of data that is used for predicting risk of various disorders. Prenatal risk assessment is based on multiple clinical variables and overall performance is defined by how well the risk algorithm is optimized for the population in question. This article evaluates machine learning algorithms to improve performance of first trimester screening of Down syndrome. Machine learning algorithms pose an adaptive alternative to develop better risk assessment models using the existing clinical variables. Two real-world data sets were used to experiment with multiple classification algorithms. Implemented models were tested with a third, real-world, data set and performance was compared to a predicate method, a commercial risk assessment software. Best performing deep neural network model gave an area under the curve of 0.96 and detection rate of 78% with 1% false positive rate with the test data. Support vector machine model gave area under the curve of 0.95 and detection rate of 61% with 1% false positive rate with the same test data. When compared with the predicate method, the best support vector machine model was slightly inferior, but an optimized deep neural network model was able to give higher detection rates with same false positive rate or similar detection rate but with markedly lower false positive rate. This finding could further improve the first trimester screening for Down syndrome, by using existing clinical variables and a large training data derived from a specific population. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.

  6. Fetal aneuploidy detection by maternal plasma DNA sequencing: a technology assessment.

    PubMed

    Walsh, Judith M E; Goldberg, James D

    2013-06-01

    The American College of Obstetricians and Gynecologists currently recommends that all pregnant women be offered screening for chromosomal abnormalities, regardless of maternal age. Traditional screening tests have detection rates ranging from 85% to 90% and false-positive rates of 3% to 5%. A woman with an abnormal noninvasive test is offered a diagnostic test, but diagnostic tests are associated with a risk of pregnancy loss. Recently, analysis of cell-free fetal DNA (cffDNA) in maternal blood has been shown to have potential for the accurate detection of some of the common fetal autosomal aneuploidies. As part of a technology assessment for the California Technology Assessment Forum, we critically reviewed the evidence for the use of cffDNA as a prenatal screening test. We evaluated the evidence for its use as either a 'primary' or an 'advanced' screening test and for its use in screening for three different trisomies: 21, 18, and 13. We evaluated whether the use of cffDNA met established technology assessment criteria and established conclusions about evidence-based use of this new technology. © 2013 John Wiley & Sons, Ltd.

  7. A comparison of an immunological faecal occult blood test Fecatwin sensitive/FECA EIA with Haemoccult in population screening for colorectal cancer.

    PubMed Central

    Armitage, N.; Hardcastle, J. D.; Amar, S. S.; Balfour, T. W.; Haynes, J.; James, P. D.

    1985-01-01

    Two faecal occult blood tests, a simple chemical test Haemoccult and an immunological test, Fecatwin Sensitive/Feca EIA, were offered to 3,225 asymptomatic individuals as screening for colorectal cancer. One thousand three hundred and four (44%) completed and returned the tests and of these 126 (9.7%) were found to be positive - Haemoccult 40 (3%) and Feca EIA 106 (8.1%). Five cancers (4 Dukes' Stage A, 1 Dukes' Stage C) and 23 adenomas greater than 1 cm were detected - rates of 3.8 per 1000 persons screened and 17.7 per 1000 persons screened respectively. Of the five cancers identified 5 were Feca EIA positive and 3 were Haemoccult positive. Of the 23 adenomas greater than 1 cm diameter identified, J1 were Feca EIA positive and 20 were Haemoccult positive. Seventy-eight Feca EIA positive subjects were investigated and no neoplastic disease was identified. Whilst this sensitive immunological test increases the yield of carcinomas, the high false positive rate makes it unsuitable for population screening for colorectal cancer in its present form. PMID:4005139

  8. First day of life pulse oximetry screening to detect congenital heart defects.

    PubMed

    Meberg, Alf; Brügmann-Pieper, Sabine; Due, Reidar; Eskedal, Leif; Fagerli, Ingebjørg; Farstad, Teresa; Frøisland, Dag Helge; Sannes, Catharina Hovland; Johansen, Ole Jakob; Keljalic, Jasmina; Markestad, Trond; Nygaard, Egil Andre; Røsvik, Alet; Silberg, Inger Elisabeth

    2008-06-01

    To evaluate the efficacy of first day of life pulse oximetry screening to detect congenital heart defects (CHDs). We performed a population-based prospective multicenter study of postductal (foot) arterial oxygen saturation (SpO(2)) in apparently healthy newborns after transfer from the delivery suite to the nursery. SpO(2) < 95% led to further diagnostic evaluations. Of 57,959 live births, 50,008 (86%) were screened. In the screened population, 35 CHDs were [corrected] classified as critical (ductus dependent, cyanotic). CHDs were prospectively registered and diagnosed in 658/57,959 (1.1%) [corrected] Of the infants screened, 324 (0.6%) failed the test. Of these, 43 (13%) had CHDs (27 critical), and 134 (41%) had pulmonary diseases or other disorders. The remaining 147 infants (45%) were healthy with transitional circulation. The median age for babies with CHDs at failing the test was 6 hours (range, 1-21 hours). For identifying critical CHDs, the pulse oximetry screening had a sensitivity rate of 77.1% (95% CI, 59.4-89.0), specificity rate of 99.4% (95% CI, 99.3-99.5), and a false-positive rate of 0.6% (95% CI, 0.5-0.7). Early pulse oximetry screening promotes early detection of critical CHDs and other potentially severe diseases. The sensitivity rate for detecting critical CHDs is high, and the false-positive rate is low.

  9. Clinical perspective of cell-free DNA testing for fetal aneuploidies.

    PubMed

    Gratacós, Eduard; Nicolaides, Kypros

    2014-01-01

    Cell-free DNA testing in maternal blood provides the most effective method of screening for trisomy 21, with a reported detection rate of 99% and a false positive rate of less than 0.1%. After many years of research, this method is now commercially available and is carried out in an increasing number of patients, and there is an expanding number of conditions that can be screened for. However, the application of these methods in clinical practice requires a careful analysis. Current first-trimester screening strategies are based on a complex combination of tests, aiming at detecting fetal defects and predicting the risk of main pregnancy complications. It is therefore necessary to define the optimal way of combining cell-free DNA testing with current first-trimester screening methods. In this concise review we describe the basis of cell-free DNA testing and discuss the potential approaches for its implementation in combination with current tests in the first trimester. © 2014 S. Karger AG, Basel.

  10. Cost-effectiveness of WHO-Recommended Algorithms for TB Case Finding at Ethiopian HIV Clinics.

    PubMed

    Adelman, Max W; McFarland, Deborah A; Tsegaye, Mulugeta; Aseffa, Abraham; Kempker, Russell R; Blumberg, Henry M

    2018-01-01

    The World Health Organization (WHO) recommends active tuberculosis (TB) case finding and a rapid molecular diagnostic test (Xpert MTB/RIF) to detect TB among people living with HIV (PLHIV) in high-burden settings. Information on the cost-effectiveness of these recommended strategies is crucial for their implementation. We conducted a model-based cost-effectiveness analysis comparing 2 algorithms for TB screening and diagnosis at Ethiopian HIV clinics: (1) WHO-recommended symptom screen combined with Xpert for PLHIV with a positive symptom screen and (2) current recommended practice algorithm (CRPA; based on symptom screening, smear microscopy, and clinical TB diagnosis). Our primary outcome was US$ per disability-adjusted life-year (DALY) averted. Secondary outcomes were additional true-positive diagnoses, and false-negative and false-positive diagnoses averted. Compared with CRPA, combining a WHO-recommended symptom screen with Xpert was highly cost-effective (incremental cost of $5 per DALY averted). Among a cohort of 15 000 PLHIV with a TB prevalence of 6% (900 TB cases), this algorithm detected 8 more true-positive cases than CRPA, and averted 2045 false-positive and 8 false-negative diagnoses compared with CRPA. The WHO-recommended algorithm was marginally costlier ($240 000) than CRPA ($239 000). In sensitivity analysis, the symptom screen/Xpert algorithm was dominated at low Xpert sensitivity (66%). In this model-based analysis, combining a WHO-recommended symptom screen with Xpert for TB diagnosis among PLHIV was highly cost-effective ($5 per DALY averted) and more sensitive than CRPA in a high-burden, resource-limited setting.

  11. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  12. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  13. Applying a CAD-generated imaging marker to assess short-term breast cancer risk

    NASA Astrophysics Data System (ADS)

    Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin

    2018-02-01

    Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (p<0.01). Thus, the study showed that CAD-generated false-positives might provide a new quantitative imaging marker to help assess short-term breast cancer risk.

  14. Expanded newborn screening: social and ethical issues.

    PubMed

    Dhondt, Jean-Louis

    2010-10-01

    Newborn screening and genetic testing have expanded rapidly in the last decade with the advent of multiplex (e.g., tandem mass spectrometry) and/or DNA technologies. However, screening panels include a large number of disorders, which may not meet all of the traditional screening criteria, established in late 1960s, and used for years to justify screening programs. After a period of expansion driven by technological advances, many reports have reconsidered the justification of expanded programs. Many factors have contributed to test-panel discrepancies between countries. The test-panel review methodology, the way health benefits are weighed against harms, and the socioeconomic-political environment all play a role. Expansion of screening also requires reconsideration of the infrastructure (ideally, in the context of national plans for rare diseases) to support testing, counselling, education, treatment, and follow-up. Consequently, economic aspects cannot be ignored and can be a limitation for expansion. New ethical questions have emerged: risks of discrimination or stigmatization, respect of the autonomy of persons to make decisions, parental anxiety resulting from a false positive test (especially when reporting to parents screening results for untreatable conditions identified as by-products of screening), etc. For disorders where there is not yet confirmation of benefit, it may be prudent to recommend pilot screening and to have a mechanism that can be used to adapt or even to stop a program.

  15. False-negative rate cannot be reduced by lowering the haemoglobin concentration cut-off in colorectal cancer screening using faecal immunochemical test.

    PubMed

    Ibañez-Sanz, Gemma; Garcia, Montse; Milà, Núria; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Benito, Llúcia; Padrol, Isabel; Barenys, Mercè; Moreno, Victor

    2017-09-01

    The aim of this study was to analyse false-negative (FN) results of the faecal immunochemical test (FIT) and its determinants in a colorectal cancer screening programme in Catalonia. We carried out a cross-sectional study among 218 screenees with a negative FIT result who agreed to undergo a colonoscopy. A false-negative result was defined as the detection, at colonoscopy, of intermediate/high-risk polyps or colorectal cancer in a patient with a previous negative FIT (<20 µgHb/g). Multivariate logistic regression models were constructed to identify sociodemographic (sex, age) and screening variables (quantitative faecal haemoglobin, colonoscopy findings) related to FN results. Adjusted odds ratios and their 95% confidence intervals were estimated. There were 15.6% FN FIT results. Faecal haemoglobin was undetected in 45.5% of these results and was below 4 µgHb/g in 94.0% of the individuals with a FN result. About 60% of the lesions were located in the proximal colon, whereas the expected percentage was 30%. Decreasing the positivity threshold of FIT does not increase the detection rate of advanced neoplasia, but may increase the costs and potential adverse effects.

  16. Decision-Making Regarding Mammography Screening for Older Women.

    PubMed

    Schonberg, Mara A

    2016-12-01

    The population is aging, and breast cancer incidence increases with age, peaking between the ages of 75 and 79. However, it is not known whether mammography screening helps women aged 75 and older live longer because they have not been included in randomized controlled trials evaluating mammography screening. Guidelines recommend that older women with less than a 10-year life expectancy not be screened because it takes approximately 10 years before a screen-detected breast cancer may affect an older woman's survival. Guidelines recommend that clinicians discuss the benefits and risks of screening with women aged 75 and older with a life expectancy of 10 years or longer to help them elicit their values and preferences. It is estimated that two of 1,000 women who continue to be screened every other year from age 70 to 79 may avoid breast cancer death, but 12% to 27% of these women will experience a false-positive test, and 10% to 20% of women who experience a false-positive test will undergo a breast biopsy. In addition, approximately 30% of screen-detected cancers would not otherwise have shown up in an older woman's lifetime, yet nearly all older women undergo treatment for these breast cancers, and the risks of treatment increase with age. To inform decision-making, tools are available to estimate life expectancy and to educate older women about the benefits and harms of mammography screening. Guides are also available to help clinicians discuss stopping screening with older women with less than a 10-year life expectancy. Ideally, screening decisions would consider an older woman's life expectancy, breast cancer risk, and her values and preferences. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  17. Psychosocial Distress and Knowledge Deficiencies in Parents of Children in Ireland Who Carry an Altered Cystic Fibrosis Gene.

    PubMed

    Quigley, S J; Linnane, B; Connellan, S; Ward, A; Ryan, P

    2018-06-01

    Significant gaps have been identified in parental understanding of CF newborn screening and the consequences of carrying an altered CF gene. Seven potential causes of psychosocial adversity arising from false positive newborn screening for CF have been identified. The current study aimed to increase parents understanding of CF, reduce their levels of stress, and investigate psychosocial adversity arising from false-positive screening. This national study was run over one year in the Republic of Ireland. Parents were recruited for the study following a diagnostic sweat test confirming their child carried a single altered CF gene. Parents were randomly assigned into a control and intervention group, with those in the intervention group receiving a carefully designed information pack. All parents took part in semi-structured interviews. Parents (n = 16) who received an information pack had significantly higher CF knowledge scores than parents (n = 16) in the control group. 66% of parents in the control group misunderstood the health implications of carrying an altered CF gene, no parents in the intervention group had the same misunderstanding. There was no significant difference in stress scores between the groups. Parents of infants who had more than one sweat test due to insufficient sweat quantity had higher overall stress percentiles (50%), than parents of infants who had one sweat test (30%), indicating greater parental stress. The combination of written and audio-visual information contained in the information pack successfully increased parents comprehension of CF. The study also evaluates the potential for psychosocial adversity following false positive newborn screening for CF.

  18. Pre-Participation Musculoskeletal and Cardiac Screening of Male Athletes in the United Arab Emirates

    PubMed Central

    Alattar, A; Ghani, S; Mahdy, N; Hussain, H; Maffulli, N

    2014-01-01

    This study presents the results of pre-participation musculoskeletal and cardiac screening using the Lausanne recommendations, which include a personal and family history, physical examination and electrocardiography. Cross sectional study using the Lausanne screenings and the European Society of Cardiology (ESC) recommendations carried out at Al-Ahli club in Dubai, United Arab Emirates. 230 male athletes participating in organised sports were included. Exclusion criteria were those under 14 or over 35 years old, females and athletes with established cardiovascular disease. Primary outcome are the results of Lausanne screening with outline of the negative, positive and false positive results and number needed to screen. Secondary outcomes include the results of musculoskeletal and neurological screening. A total of 174 (76%) athletes had a negative screening result. Fifty-four athletes (23%) underwent additional testing. Forty-seven athletes (20.4%) had false positive screening results. Seven athletes (3%) had a positive screening result and four athletes (2%) were restricted from sport. The number of athletes needed to screen to detect one lethal cardiovascular condition was 33 athletes. The Lausanne recommendations are well suited for the United Arab Emirates. The number needed to screen to detect one athlete with serious cardiovascular disease is acceptable at 33. PMID:24809035

  19. High throughput screening (HTS) for phototoxicity hazard using the in vitro 3T3 neutral red uptake assay.

    PubMed

    Jones, P A; King, A V

    2003-01-01

    Testing for phototoxic hazard is usually carried out for product ingredients intended for use on skin, which may be exposed to sunlight. Unilever currently uses the validated in vitro 3T3 Neutral Red Uptake phototoxicity test (NRU PT). This protocol involves 2-3 experiments, each taking 3 days to perform. One person can test up to seven test materials plus positive control at any one time, requiring approximately 0.5 g test material. Higher throughput is required where libraries of potential actives are being generated and screening for potential phototoxicants is required. A proposed HTS protocol would use the NRU PT, but only one concentration (10 microg/ml) in a single experiment. The validity of the HTS protocol was investigated by a retrospective examination of data from 86 materials previously tested. Phototoxic hazard predictions made using the conventional NRU PT were compared with those obtained if only data at 10 microg/ml were considered. A majority of 73 materials (84.9%) gave agreement in predictions between the two protocols; for 13 materials (15.1%) the assessments did not agree. There were no false positives; however, there were some false negatives, i.e., predicted as phototoxic from the conventional assay, but non-phototoxic at 10 microg/ml. As this protocol is intended for screening purposes only it is considered that this would be acceptable at this stage in material selection. One person could screen 128 test materials in 3 days, requiring <1 mg test material, giving a substantial increase in productivity. Any material selected for further development and inclusion in a formulation may require further confirmatory testing, e.g. using a human skin model assay for phototoxicity.

  20. Screening for diabetes and prediabetes should be cost-saving in patients at high risk.

    PubMed

    Chatterjee, Ranee; Narayan, K M Venkat; Lipscomb, Joseph; Jackson, Sandra L; Long, Qi; Zhu, Ming; Phillips, Lawrence S

    2013-07-01

    Although screening for diabetes and prediabetes is recommended, it is not clear how best or whom to screen. We therefore compared the economics of screening according to baseline risk. Five screening tests were performed in 1,573 adults without known diabetes--random plasma/capillary glucose, plasma/capillary glucose 1 h after 50-g oral glucose (any time, without previous fast, plasma glucose 1 h after a 50-g oral glucose challenge [GCTpl]/capillary glucose 1 h after a 50-g oral glucose challenge [GCTcap]), and A1C--and a definitive 75-g oral glucose tolerance test. Costs of screening included the following: costs of testing (screen plus oral glucose tolerance test, if screen is positive); costs for false-negative results; and costs of treatment of true-positive results with metformin, all over the course of 3 years. We compared costs for no screening, screening everyone for diabetes or high-risk prediabetes, and screening those with risk factors based on age, BMI, blood pressure, waist circumference, lipids, or family history of diabetes. Compared with no screening, cost-savings would be obtained largely from screening those at higher risk, including those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, with differences of up to -46% of health system costs for screening for diabetes and -21% for screening for dysglycemia110, respectively (all P < 0.01). GCTpl would be the least expensive screening test for most high-risk groups for this population over the course of 3 years. From a health economics perspective, screening for diabetes and high-risk prediabetes should target patients at higher risk, particularly those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, for whom screening can be most cost-saving. GCTpl is generally the least expensive test in high-risk groups and should be considered for routine use as an opportunistic screen in these groups.

  1. The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial.

    PubMed

    Renshaw, A A; Lezon, K M; Wilbur, D C

    2001-04-25

    Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.

  2. Positive predictive value estimates for cell-free noninvasive prenatal screening from data of a large referral genetic diagnostic laboratory.

    PubMed

    Petersen, Andrea K; Cheung, Sau Wai; Smith, Janice L; Bi, Weimin; Ward, Patricia A; Peacock, Sandra; Braxton, Alicia; Van Den Veyver, Ignatia B; Breman, Amy M

    2017-12-01

    Since its debut in 2011, cell-free fetal DNA screening has undergone rapid expansion with respect to both utilization and coverage. However, conclusive data regarding the clinical validity and utility of this screening tool, both for the originally included common autosomal and sex-chromosomal aneuploidies as well as the more recently added chromosomal microdeletion syndromes, have lagged behind. Thus, there is a continued need to educate clinicians and patients about the current benefits and limitations of this screening tool to inform pre- and posttest counseling, pre/perinatal decision making, and medical risk assessment/management. The objective of this study was to determine the positive predictive value and false-positive rates for different chromosomal abnormalities identified by cell-free fetal DNA screening using a large data set of diagnostic testing results on invasive samples submitted to the laboratory for confirmatory studies. We tested 712 patient samples sent to our laboratory to confirm a cell-free fetal DNA screening result, indicating high risk for a chromosome abnormality. We compiled data from all cases in which the indication for confirmatory testing was a positive cell-free fetal DNA screen, including the common trisomies, sex chromosomal aneuploidies, microdeletion syndromes, and other large genome-wide copy number abnormalities. Testing modalities included fluorescence in situ hybridization, G-banded karyotype, and/or chromosomal microarray analysis performed on chorionic villus samples, amniotic fluid, or postnatally obtained blood samples. Positive predictive values and false-positive rates were calculated from tabulated data. The positive predictive values for trisomy 13, 18, and 21 were consistent with previous reports at 45%, 76%, and 84%, respectively. For the microdeletion syndrome regions, positive predictive values ranged from 0% for detection of Cri-du-Chat syndrome and Prader-Willi/Angelman syndrome to 14% for 1p36 deletion syndrome and 21% for 22q11.2 deletion syndrome. Detection of sex chromosomal aneuploidies had positive predictive values of 26% for monosomy X, 50% for 47,XXX, and 86% for 47,XXY. The positive predictive values for detection of common autosomal and sex chromosomal aneuploidies by cell-free fetal DNA screening were comparable with other studies. Identification of microdeletions was associated with lower positive predictive values and higher false-positive rates, likely because of the low prevalence of the individual targeted microdeletion syndromes in the general population. Although the obtained positive predictive values compare favorably with those seen in traditional screening approaches for common aneuploidies, they highlight the importance of educating clinicians and patients on the limitations of cell-free fetal DNA screening tests. Improvement of the cell-free fetal DNA screening technology and continued monitoring of its performance after introduction into clinical practice will be important to fully establish its clinical utility. Nonetheless, our data provide valuable information that may aid result interpretation, patient counseling, and clinical decision making/management. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Parent Experience With False-Positive Newborn Screening Results for Cystic Fibrosis.

    PubMed

    Hayeems, Robin Z; Miller, Fiona A; Barg, Carolyn J; Bombard, Yvonne; Kerr, Elizabeth; Tam, Karen; Carroll, June C; Potter, Beth K; Chakraborty, Pranesh; Davies, Christine; Milburn, Jennifer; Patton, Sarah; Bytautas, Jessica P; Taylor, Louise; Price, April; Gonska, Tanja; Keenan, Katherine; Ratjen, Felix; Guttmann, Astrid

    2016-09-01

    The risk of psychosocial harm in families of infants with false-positive (FP) newborn bloodspot screening (NBS) results for cystic fibrosis (CF) is a longstanding concern. Whether well designed retrieval and confirmatory testing systems can mitigate risks remains unknown. Using a mixed-methods cohort design, we obtained prospective self-report data from mothers of infants with FP CF NBS results 2 to 3 months after confirmatory testing at Ontario's largest follow-up center, and from a randomly selected control sample of mothers of screen negative infants from the same region. Mothers completed a questionnaire assessing experience and psychosocial response. A sample of mothers of FP infants completed qualitative interviews. One hundred thirty-four mothers of FP infants (response rate, 55%) and 411 controls (response rate, 47%) completed questionnaires; 54 mothers of FP infants were interviewed. Selected psychosocial response measures did not detect psychosocial distress in newborns or 1 year later (P > .05). Mothers recalled distress during notification of the positive result and in the follow-up testing period related to fear of chronic illness, but valued the screening system of care in mitigating concerns. Although immediate distress was reported among mothers of FP infants, selected psychometric tools did not detect these concerns. The NBS center from which mothers were recruited minimizes delay between notification and confirmatory testing and ensures trained professionals are communicating results and facilitating follow-up. These factors may explain the presence of minimal psychosocial burden. The screening system reflected herein may be a model for NBS programs working to minimize FP-related psychosocial harm. Copyright © 2016 by the American Academy of Pediatrics.

  4. Impact of Risk Factors on Different Interval Cancer Subtypes in a Population-Based Breast Cancer Screening Programme

    PubMed Central

    Blanch, Jordi; Sala, Maria; Ibáñez, Josefa; Domingo, Laia; Fernandez, Belén; Otegi, Arantza; Barata, Teresa; Zubizarreta, Raquel; Ferrer, Joana; Castells, Xavier; Rué, Montserrat; Salas, Dolores

    2014-01-01

    Background Interval cancers are primary breast cancers diagnosed in women after a negative screening test and before the next screening invitation. Our aim was to evaluate risk factors for interval cancer and their subtypes and to compare the risk factors identified with those associated with incident screen-detected cancers. Methods We analyzed data from 645,764 women participating in the Spanish breast cancer screening program from 2000–2006 and followed-up until 2009. A total of 5,309 screen-detected and 1,653 interval cancers were diagnosed. Among the latter, 1,012 could be classified on the basis of findings in screening and diagnostic mammograms, consisting of 489 true interval cancers (48.2%), 235 false-negatives (23.2%), 172 minimal-signs (17.2%) and 114 occult tumors (11.3%). Information on the screening protocol and women's characteristics were obtained from the screening program registry. Cause-specific Cox regression models were used to estimate the hazard ratios (HR) of risks factors for interval cancer and incident screen-detected cancer. A multinomial regression model, using screen-detected tumors as a reference group, was used to assess the effect of breast density and other factors on the occurrence of interval cancer subtypes. Results A previous false-positive was the main risk factor for interval cancer (HR = 2.71, 95%CI: 2.28–3.23); this risk was higher for false-negatives (HR = 8.79, 95%CI: 6.24–12.40) than for true interval cancer (HR = 2.26, 95%CI: 1.59–3.21). A family history of breast cancer was associated with true intervals (HR = 2.11, 95%CI: 1.60–2.78), previous benign biopsy with a false-negatives (HR = 1.83, 95%CI: 1.23–2.71). High breast density was mainly associated with occult tumors (RRR = 4.92, 95%CI: 2.58–9.38), followed by true intervals (RRR = 1.67, 95%CI: 1.18–2.36) and false-negatives (RRR = 1.58, 95%CI: 1.00–2.49). Conclusion The role of women's characteristics differs among interval cancer subtypes. This information could be useful to improve effectiveness of breast cancer screening programmes and to better classify subgroups of women with different risks of developing cancer. PMID:25333936

  5. [Screening for intellectual disability among adults].

    PubMed

    Søndenaa, Erik; Linaker, Olav; Bjørgen, Tale Gjertine; Nøttestad, Jim Aage

    2010-08-12

    Instigation of proper measures in case of intellectual disability is often conditioned by a diagnosis. Our aim was to assess whether the Hayes Ability Screening Index (HASI) is a suitable screening instrument for intellectual disability among adults. The article is based on three former studies aimed at validating HASI for use among patients referred for neuropsychological examination, prison inmates and psychiatric inpatients in community mental health centres. The sample consisted of 264 persons. The HASI correlated with the more comprehensive scales of assessing intellectual functioning (Wechsler tests) (r = 0.73, p < 0.001). With a cut-off value of 85, HASI had a sensitivity of 0.97 and a specificity of 0.61 in relation to an IQ < 70. HASI is associated with few false negatives, but a large number of false positives. This implies that an intellectual disability is concluded in too many cases; a positive screening should be followed up with a more thorough assessment.

  6. Beta lactam antibiotics residues in cow's milk: comparison of efficacy of three screening tests used in Bosnia and Herzegovina.

    PubMed

    Fejzic, Nihad; Begagic, Muris; Šerić-Haračić, Sabina; Smajlovic, Muhamed

    2014-08-27

    Beta lactam antibiotics are widely used in therapy of cattle, particularly for the treatment of mastitis.  Over 95% of residue testing in dairies in Bosnia and Herzegovina is for Beta lactams. The aim of this paper is to compare the efficacy of three most common screening tests for Beta lactam residues in cow's milk in our country. The tests used in the study are SNAP β Lactam test (Idexx), Rosa Charm β Lactam test and Inhibition MRL test. Study samples included: standardized concentrations of penicillin solution (0, 2, 3, 4, 5 and 6 ppb). In addition we tested milk samples from three equal size study groups (not receiving any antibiotic therapy, treated with Beta lactams for mastitis and treated with Beta lactams for diseases other than mastitis). Sensitivity and specificity were determined for each test, using standard penicillin concentrations with threshold value set at concentration of 4 ppb (Maximum residue level - MLR). Additionally we determined proportions of presumably false negative and false positive results for each test using results of filed samples testing. Agreement of test results for each test pair was assessed through Kappa coefficients interpreted by Landis-Koch scale. Detection level of all tests was shown to be well below MRL. This alongside with effects of natural inhibitors in milk contributed to finding of positive results in untreated and treated animals after the withholding period. Screening tests for beta lactam residues are important tools for ensuring that milk for human consumption is free from antibiotics residues.

  7. Beta lactam antibiotics residues in cow’s milk: comparison of efficacy of three screening tests used in Bosnia and Herzegovina

    PubMed Central

    Fejzić, Nihad; Begagić, Muris; Šerić-Haračić, Sabina; Smajlović, Muhamed

    2014-01-01

    Beta lactam antibiotics are widely used in therapy of cattle, particularly for the treatment of mastitis. Over 95% of residue testing in dairies in Bosnia and Herzegovina is for Beta lactams. The aim of this paper is to compare the efficacy of three most common screening tests for Beta lactam residues in cow’s milk in our country. The tests used in the study are SNAP β Lactam test (Idexx), Rosa Charm β Lactam test (Charm Sciences) and Inhibition MRL test (A&M). Study samples included: standardized concentrations of penicillin solution (0, 2, 3, 4, 5 and 6 ppb). In addition we tested milk samples from three equal size study groups (not receiving any antibiotic therapy, treated with Beta lactams for mastitis and treated with Beta lactams for diseases other than mastitis). Sensitivity and specificity were determined for each test, using standard penicillin concentrations with threshold value set at concentration of 4 ppb (Maximum residue level – MLR). Additionally we determined proportions of presumably false negative and false positive results for each test using results of filed samples testing. Agreement of test results for each test pair was assessed through Kappa coefficients interpreted by Landis-Koch scale. Detection level of all tests was shown to be well below MRL. This alongside with effects of natural inhibitors in milk contributed to finding of positive results in untreated and treated animals after the withholding period. Screening tests for beta lactam residues are important tools for ensuring that milk for human consumption is free from antibiotics residues. PMID:25172975

  8. Serological confirmatory testing of alveolar and cystic echinococcosis in clinical practice: results of a comparative study with commercialized and in-house assays.

    PubMed

    Reiter-Owona, Ingrid; Grüner, Beate; Frosch, Matthias; Hoerauf, Achim; Kern, Peter; Tappe, Dennis

    2009-01-01

    Sera of 50 patients with either cystic (CE) or alveolar echinococcosis (AE) in different clinical stages were examined for the presence of anti-Echinococcus-antibodies. Antibody-screening was performed with ELISA, IHA and IFAT, and confirmatory testing was done by the commercialized E. multilocularis-specific Em2plus-ELISA versus an in-house E. multilocularis-specific Em10-ELISA. Sera with discrepant confirmatory results were subjected to a commercial Echinococcus IgG Western blot (WB). In sera from patients with CE, the Em2plus-ELISA showed cross-reactions in 23.5%, whereas the Em10-ELISA did not exhibit any cross-reactivity. Cross-reactivity paralleled active infection with high antibody titers in the screening assays. In sera from patients with AE, confirmation by both ELISAs was achieved in 57.6%, mostly in patients with an advanced stage of the disease and high antibody titers in the screening assays. False-negative reactions of both ELISAs occurred in 30.3%, mostly in patients who had low antibody levels in the screening tests. The Em2plus-ELISA exhibited fewer false-negative reactions than the Em10-ELISA. The WB confirmed the positive results of either assay and was the assay with the highest reliability at different stages of CE and AE, followed by the Em2plus-ELISA for AE. High antibody titers in the screening assays will favour the detection of species-specific antibodies in either form.

  9. Routine bacterial screening of apheresis platelets on Day 4 using a rapid test: a 4-year single-center experience.

    PubMed

    Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M

    2013-10-01

    The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.

  10. Monothermal caloric screening test performance: a relative operating characteristic curve analysis.

    PubMed

    Murnane, Owen D; Akin, Faith W; Lynn, Susan G; Cyr, David G

    2009-06-01

    The objective of the present study was to evaluate the performance of the monothermal caloric screening test in a large sample of patients. A retrospective analysis of the medical records of 1002 consecutive patients who had undergone vestibular assessment at the Mayo Clinic during the years 1989 and 1990 was conducted. Patients with incomplete alternate binaural bithermal (ABB) caloric testing, congenital or periodic alternating nystagmus, or bilateral vestibular loss were excluded from the study. Clinical decision theory analyses (relative operating characteristic curves) were used to determine the accuracy with which the monothermal warm (MWST) and monothermal cool (MCST) caloric screening tests predicted the results of the ABB caloric test. Cumulative distributions were constructed as a function of the cutoff points for monothermal interear difference (IED) to select the cutoff point associated with any combination of true-positive and false-positive rates. Both MWST and MCST performed well above chance level. The test performance for the MWST was significantly better than that of the MCST for three of the four ABB gold standards. A 10% IED cutoff point for the MWST yielded a false-negative rate of either 1% (UW >or=25%) or 3% (UW >or=20%). The use of a 10% IED (UW >or=25%) for the MWST would have resulted in a 40% reduction (N = 294) in the number of ABB caloric tests performed on patients without a unilateral weakness. The results of this study indicated that the MWST decreases test time without sacrificing the sensitivity of the ABB caloric test.

  11. [Effectivity of screening, concepts and attitudes towards metabolic síndrome: a study in bipolar patients followed in Hospital Santa Maria psychiatric consultation].

    PubMed

    Guerreiro, Diogo Frasquilho; Navarro, Rita; Telles-Correia, Diogo; Martins, Paulo; Trigo, Elsa; Silva, Manuela; Neves, António; Góis, Carlos; Figueira, Maria Luísa

    2010-01-01

    The Metabolic Syndrome (MS) is constituted by a set of specific metabolic alterations being postulated that the main dysfunction is insulin resistance, associated with abdominal type obesity, hypertension, hyperglycemia and dyslipidemia. Epidemiological data indicates prevalence of MS of about 25%. Estimates point to higher prevalence of MS in bipolar (BP) patients, between 30 to 35%. Cost-effective screening methods, not recurring to blood test, have been researched. Test the viability of MS screening without using blood tests. Analyse knowledge and importance given to the issue of MS in Bipolar patients. Observational, cross-sectional, exploratory study. Random sample of 15 BP patients, in euthymic phase, between 18 and 65 years. Semi-structured interview, YMRS, HAMD were applied. MS diagnosis was investigated according to the International Diabetes Federation (IDF), including blood tests. Screening of MS was defined positive if blood pressure > or = to 130/85 or on anti-hypertensive medication and Abdominal Perimeter > 90 cm in males or > 80 cm in females. Afterwards a questionnaire about knowledge, attitudes and concerns on MS was applied. 14 patients completed the investigation protocol, 1 patient didn't do blood testing for unknown reasons. Five patients (36%) met IDF criteria for MS. Screening sensitivity was 80% and specificity 78% on our sample (1 false positive and 2 false negative). Twelve patients (80%) were overweight or obese. Mean IMC in patients that met IDF criteria for MS was 30 while in the other group mean IMC was 26, showing statistical significance. Only 3 (20%) have ever heard about MS, but the majority of the patients were concerned, in decreasing order, about weight gain, blood pressure cholesterol and hyperglycemia control. Although limited by small sample size, this study strengthens the idea that MS screening can be effective in clinical practice, it also indicates the need to educate BP patients about MS and to prevent overweight.

  12. Comparison of cytology, HPV DNA testing and HPV 16/18 genotyping alone or combined targeting to the more balanced methodology for cervical cancer screening.

    PubMed

    Chatzistamatiou, Kimon; Moysiadis, Theodoros; Moschaki, Viktoria; Panteleris, Nikolaos; Agorastos, Theodoros

    2016-07-01

    The objective of the present study was to identify the most effective cervical cancer screening algorithm incorporating different combinations of cytology, HPV testing and genotyping. Women 25-55years old recruited for the "HERMES" (HEllenic Real life Multicentric cErvical Screening) study were screened in terms of cytology and high-risk (hr) HPV testing with HPV 16/18 genotyping. Women positive for cytology or/and hrHPV were referred for colposcopy, biopsy and treatment. Ten screening algorithms based on different combinations of cytology, HPV testing and HPV 16/18 genotyping were investigated in terms of diagnostic accuracy. Three clusters of algorithms were formed according to the balance between effectiveness and harm caused by screening. The cluster showing the best balance included two algorithms based on co-testing and two based on HPV primary screening with HPV 16/18 genotyping. Among these, hrHPV testing with HPV 16/18 genotyping and reflex cytology (atypical squamous cells of undetermined significance - ASCUS threshold) presented the optimal combination of sensitivity (82.9%) and specificity relative to cytology alone (0.99) with 1.26 false positive rate relative to cytology alone. HPV testing with HPV 16/18 genotyping, referring HPV 16/18 positive women directly to colposcopy, and hrHPV (non 16/18) positive women to reflex cytology (ASCUS threshold), as a triage method to colposcopy, reflects the best equilibrium between screening effectiveness and harm. Algorithms, based on cytology as initial screening method, on co-testing or HPV primary without genotyping, and on HPV primary with genotyping but without cytology triage, are not supported according to the present analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Comparing diagnostic tests on benefit-risk.

    PubMed

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  14. Demographic factors influencing consensus opinion on the recall for women screened by mobile mammography unit in taiwan.

    PubMed

    Yu-Mei, Lee; Hsueh-Hua, Yao

    2013-09-01

    The incidence of breast cancer has had a four-fold increase from 1980 to 2005 in Taiwan. Limited data have been available on mobile breast screening in the Taiwanese population since 2009. This study aims at investigating the factors influencing consensus opinion on the recall for mobile breast screening in Taiwan. The factors were categorized by individual health background, socioeconomic status and knowledge about breast screening. There were 502 questionnaires collected from Taiwanese women examined on mobile mammography screening vehicle. Data were then analyzed by SPSS 12 via analysis of variance (ANOVA), F-test, t-test or chi-square test. Strong participation was associated with a younger age, higher educational level, higher incomes, previous history of cancer, previous family history of cancer, one or two prior mammographies, more correct recognitions of mammography, recall rate, and breast cancer risk. If the false-positive result occurred, 83.9%, 81.9% and 77.3% of the women agreed or strongly agreed to participate in noninvasive and invasive testing and screening mammography, respectively. The policy makers should notify the importance of demographic factors affecting further examination for early detection of breast cancer in Taiwan.

  15. Case Reports of Aripiprazole Causing False-Positive Urine Amphetamine Drug Screens in Children.

    PubMed

    Kaplan, Justin; Shah, Pooja; Faley, Brian; Siegel, Mark E

    2015-12-01

    Urine drug screens (UDSs) are used to identify the presence of certain medications. One limitation of UDSs is the potential for false-positive results caused by cross-reactivity with other substances. Amphetamines have an extensive list of cross-reacting medications. The literature contains reports of false-positive amphetamine UDSs with multiple antidepressants and antipsychotics. We present 2 cases of presumed false-positive UDSs for amphetamines after ingestion of aripiprazole. Case 1 was a 16-month-old girl who accidently ingested 15 to 45 mg of aripiprazole. She was lethargic and ataxic at home with 1 episode of vomiting containing no identifiable tablets. She remained sluggish with periods of irritability and was admitted for observation. UDS on 2 consecutive days came back positive for amphetamines. Case 2 was of a 20-month-old girl who was brought into the hospital after accidental ingestion of an unknown quantity of her father's medications which included aripiprazole. UDS on the first day of admission came back positive only for amphetamines. Confirmatory testing with gas chromatography-mass spectrometry (GC-MS) on the blood and urine samples were also performed for both patients on presentation to detect amphetamines and were subsequently negative. Both patients returned to baseline and were discharged from the hospital. To our knowledge, these cases represent the first reports of false-positive amphetamine urine drug tests with aripiprazole. In both cases, aripiprazole was the drug with the highest likelihood of causing the positive amphetamine screen. The implications of these false-positives include the possibility of unnecessary treatment and monitoring of patients. Copyright © 2015 by the American Academy of Pediatrics.

  16. Discordant HIV Test Results: Implications on Perinatal and Haemotransfusion Screening for HIV Infection, Cape Coast, Ghana.

    PubMed

    Tetteh, Ato Kwamena; Agyarko, Edward

    2017-01-01

    Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.

  17. Screening for Syphilis: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D

    2016-06-07

    Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.

  18. Optimizing urine drug testing for monitoring medication compliance in pain management.

    PubMed

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were <1% so we eliminated this testing from our panel. We also lowered the screening cutoff for cocaine to meet the clinical needs of the pain management center. In addition, we changed our testing algorithm for 6-acetylmorphine, benzodiazepines, and methadone. For example, due the high rate of false negative results using our immunoassay-based benzodiazepine screen, we removed the screening portion of the algorithm and now perform benzodiazepine confirmation up front in all specimens by liquid chromatography-tandem mass spectrometry. Conducting an interdisciplinary quality improvement project allowed us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  19. Hygiene-therapists could be used to screen for dental caries and periodontal disease.

    PubMed

    Richards, Derek

    2015-12-01

    A purposive sample of large NHS dental practices with a minimum of three surgeries employing at least one hygiene-therapist (HT) was taken. Asymptomatic patients attending for routine checkups who consented to the study underwent a screen by H-T for dental caries and periodontal disease (index test) followed by a screen by a general dental practitioner (reference test). Patients were recruited consecutively. H-Ts and dentists attended a compulsory training day, which covered recruitment, consenting, screening process, calibration using stock photographs and patient record form completion. Diagnostic threshold for caries was any tooth in the patient's mouth that showed evidence of frank cavitation or shadowing and opacity that would indicate dental caries into the dentine. The diagnostic threshold for periodontal disease was any pocket in the patient's mouth where the black-band of a basic periodontal examination (BPE) probe (3.5 to 5.5 mm) partially or totally disappeared (ie BPE code 3). The index test was compared with the reference test to determine true-positive, false-positive, false-negative and true-negative values. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic odds ratios are shown in Table 1. Eighteen hundred and ninety-nine patients consented to dental screening with 996 patients being randomly allocated to see the dentist first and 903 H-T first. The time interval between the index and reference test never exceeded 21 minutes. With the exception of two practices failing to collect data on smoking and dentures there were no missing results regarding the outcome of a positive or negative screening decision. No adverse events were reported. Mean screening time was five min 25 s for H-Ts and four min 26 s for dentists. Dentists identified 668 patients with caries (Prevalence of 0.35) while H-Ts classified 548 positive and correctly identified 1,047 of the 1,231 patients with no caries. Dentists identified 1074 patients with at least one pocket exceeding 3.5 mm in depth. Of these 935 were correctly identified by the H-Ts. For the 825 screened as negative by the dentist H-Ts correctly identified 621. The results suggest that hygiene-therapists could be used to screen for dental caries and periodontal disease. This has important ramifications for service design in public-funded health systems.

  20. Print information to inform decisions about mammography screening participation in 16 countries with population-based programs.

    PubMed

    Zapka, Jane G; Geller, Berta M; Bulliard, Jean-Luc; Fracheboud, Jacques; Sancho-Garnier, Helene; Ballard-Barbash, Rachel

    2006-10-01

    To profile and compare the content and presentation of written communications related to informed decision-making about mammography. Materials from 16 screening programs organized at the national or regional level were analyzed according to five major information domains suggested by the international literature. A majority of countries provided information on the program (interval, cost and quality). There was considerable variability in comprehensiveness of elements in the domains, e.g., test characteristics (false positive/negative) and pros and cons of screening. The majority noted the likelihood of recall for further tests, few commented on the risks of additional tests or finding unimportant tumors. The audit also found variation in presentation (words and pictures). Presentation of comprehensive, but balanced information on screening benefits and risks is complex and daunting. Issues such as framing effects, coupled with debate about screening efficacy are challenging to the design of effective information tools. The objective of increasing screening prevalence at the population level must be balanced with objectively presenting complete and clear information. Additional research is needed on how information (and mode of presentation) impact screening decisions. Public health officials need to articulate their objectives and review written communication according to important decision-making domains.

  1. CITRUS, cervical cancer screening trial by randomization of HPV testing intervention for upcoming screening: Design, methods and baseline data of 18,471 women.

    PubMed

    Morisada, Tohru; Teramoto, Katsuhiro; Takano, Hirokuni; Sakamoto, Ikuko; Nishio, Hiroshi; Iwata, Takashi; Hashi, Akihiko; Katoh, Ryohei; Okamoto, Aikou; Sasaki, Hiroshi; Nakatani, Eiji; Teramukai, Satoshi; Aoki, Daisuke

    2017-10-01

    To assess the efficacy of screening with concurrent liquid-based cytology and human papillomavirus (HPV) testing for primary cervical cancer screening, we initiated a randomized trial entitled CervIcal cancer screening Trial by Randomization of HPV testing intervention for Upcoming Screening (CITRUS). Between June 2013 and March 2015, women aged 30-64 years of age who participated in a regular cervical cancer screening program (every 2 years) were invited to enrollment of our study. After giving their informed consent, 18,402 women were randomly assigned to liquid-based cytology as the control group (n=9145) or to HPV DNA testing with liquid-based cytology as the intervention group (n=9257). We subsequently compared the incidence rate of cervical intraepithelial neoplasia (CIN), the rate of false positive tests and the rate of overdiagnosis, as well as assessing the risks and benefits of receiving screening for women in both groups. The primary outcome of our study was the incidence of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) during the study period of around 6 years. In the control group, 97.9% of women were NILM, and 2.06% ASC-US or worse (ASC-US+). In the intervention group, 87.13% of women were NILM/HPV negative, 0.72% ASC-US/HPV negative, 10.34% NILM/HPV positive, 0.69% ASC-US/HPV positive, 0.90% worse than ASC-US/either HPV. Positive HPV testing was not linearly related to age in our study. Insights from CITRUS will provide future prospects for cervical cancer screening focused on the use of HPV testing in Japan. NCT01895517, UMIN000010843, TRIUC1312. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Serologic screening for Trypanosoma cruzi among blood donors in central Brazil.

    PubMed

    de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F

    1992-01-01

    The study reported here compares results obtained by blood banks screening sera for chagasic (Trypanosoma cruzi) infection with results obtained by the Chagas' Disease Reference Laboratory of the Federal University of Goiás in Goiânia, Brazil. It also evaluates results obtained using the ELISA technique to screen the study sera. The survey used data from six of eight blood banks serving the city of Goiânia, an urban region of Central Brazil where Chagas' disease is highly endemic. The survey population consisted of 1,513 voluntary first-time blood donors whose donations occurred between October 1988 and April 1989. This group included 50% of all the first-time blood donors in that period. The six participating blood banks, which accounted for about 90% of all blood donations in Goiânia during the study period, routinely used indirect hemagglutination (IHA) and complement fixation (CF) tests to screen sera for antibodies to T. cruzi. Comparison of the results provided by the blood banks with the reference laboratory's results indicated a relative sensitivity of 77%, which ranged from 50% to 100% depending on the blood bank studied. The comparison, which found 12 false negative results, indicated that transfusions of infected blood might have occurred despite the serologic screening performed by the blood banks. Relative to the standard of positivity established for the study, the enzyme-linked immunosorbent assay (ELISA) technique was found to have a sensitivity of 96.3%. Considering as positive only those sera yielding positive IHA and indirect immunofluorescence (IIF) test results, the ELISA technique yielded 2 false negative and 41 false positive responses.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Demand for Colonoscopy in Colorectal Cancer Screening Using a Quantitative Fecal Immunochemical Test and Age/Sex-Specific Thresholds for Test Positivity.

    PubMed

    Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi

    2018-06-01

    Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.

  4. 42 CFR 493.35 - Application for a certificate of waiver.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Application for a certificate of waiver. 493.35 Section 493.35 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... laboratory testing, health screening fairs, or other temporary testing locations may be covered under the...

  5. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.

    PubMed

    Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J

    2005-02-01

    Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

  6. The evolving role of new imaging methods in breast screening.

    PubMed

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Patient factors associated with non-attendance at colonoscopy after a positive screening faecal occult blood test.

    PubMed

    Plumb, Andrew A; Ghanouni, Alex; Rainbow, Sandra; Djedovic, Natasha; Marshall, Sarah; Stein, Judith; Taylor, Stuart A; Halligan, Steve; Lyratzopoulos, Georgios; von Wagner, Christian

    2017-03-01

    Background Screening participants with abnormal faecal occult blood test results who do not attend further testing are at high risk of colorectal cancer, yet little is known about their reasons for non-attendance. Methods We conducted a medical record review of 170 patients from two English Bowel Cancer Screening Programme centres who had abnormal guaiac faecal occult blood test screening tests between November 2011 and April 2013 but did not undergo colonoscopy. Using information from patient records, we coded and categorized reasons for non-attendance. Results Of the 170 patients, 82 were eligible for review, of whom 66 had at least one recorded reason for lack of colonoscopy follow-up. Reasons fell into seven main categories: (i) other commitments, (ii) unwillingness to have the test, (iii) a feeling that the faecal occult blood test result was a false positive, (iv) another health issue taking priority, (v) failing to complete bowel preparation, (vi) practical barriers (e.g. lack of transport), and (vii) having had or planning colonoscopy elsewhere. The most common single reasons were unwillingness to have a colonoscopy and being away. Conclusions We identify a range of apparent reasons for colonoscopy non-attendance after a positive faecal occult blood test screening. Education regarding the interpretation of guaiac faecal occult blood test findings, offer of alternative confirmatory test options, and flexibility in the timing or location of subsequent testing might decrease non-attendance of diagnostic testing following positive faecal occult blood test.

  8. First-trimester contingent screening for trisomy 21 by biomarkers and maternal blood cell-free DNA testing.

    PubMed

    Nicolaides, K H; Wright, D; Poon, L C; Syngelaki, A; Gil, M M

    2013-07-01

    To define risk cut-offs with corresponding detection rates (DR) and false-positive rates (FPR) in screening for trisomy 21 using maternal age and combinations of first-trimester biomarkers in order to determine which women should undergo contingent maternal blood cell-free (cf) DNA testing. From singleton pregnancies undergoing screening for aneuploidies at three UK hospitals between March 2006 and May 2012, we analyzed prospectively collected data on the following biomarkers: fetal nuchal translucency thickness (NT) and ductus venosus pulsatility index for veins (DV-PIV) at 11 + 0 to 13 + 6 weeks' gestation and serum free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PlGF) and alpha-fetoprotein (AFP) at 8 + 0 to 13 + 6 weeks. Estimates of risk cut-offs, DRs and FPRs were derived for combinations of biomarkers and these were used to define the best strategy for contingent cfDNA testing. In contingent screening, detection of 98% of fetuses with trisomy 21 at an overall invasive testing rate < 0.5% can be potentially achieved by offering cfDNA testing to about 36%, 21% and 11% of cases identified by first-line screening using the combined test alone, using the combined test with the addition of serum PlGF and AFP and using the combined test with the addition of PlGF, AFP and DV-PIV, respectively. Effective first-trimester screening for trisomy 21, with DR of 98% and invasive testing rate < 0.5%, can be potentially achieved by contingent screening incorporating biomarkers and cfDNA testing. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.

  9. Cost Analysis of Cot-Side Screening Methods for Neonatal Hypoglycaemia.

    PubMed

    Glasgow, Matthew J; Harding, Jane E; Edlin, Richard

    2018-06-12

    Babies at risk of neonatal hypoglycaemia are often screened using cot-side glucometers, but non-enzymatic glucometers are inaccurate, potentially resulting in over-treatment and under-treatment, and low values require laboratory confirmation. More accurate enzymatic glucometers are available but at apparently higher costs. Our objective was to compare the cost of screening for neonatal hypoglycaemia using point-of-care enzymatic and non-enzymatic glucometers. We used a decision tree to model costs, including consumables and staff time. Sensitivity analyses assessed the impact of staff time, staff costs, probability that low results are confirmed via laboratory testing, false-positive and false-negative rates of non-enzymatic glucometers, and the blood glucose concentration threshold. In the primary analysis, screening using an enzymatic glucometer cost NZD 86.94 (USD 63.47) while using a non-enzymatic glucometer cost NZD 97.08 (USD 70.87) per baby. Sensitivity analyses showed that using an enzymatic glucometer is cost saving with wide variations in staff time and costs, irrespective of the false-positive level of non-enzymatic glucometers, and where ≥78% of low values are laboratory confirmed. Where non-enzymatic glucometers may be less costly (e.g., false-negative rate exceeds 15%), instances of hypoglycaemia will be missed. Reducing the blood glucose concentration threshold to 1.94 mmol/L reduced the incidence of hypoglycaemia from 52 to 13%, and the cost of screening using a non-enzymatic glucometer to NZD 47.71 (USD 34.83). In view of their lower cost in most circumstances and greater accuracy, enzymatic glucometers should be routinely utilised for point-of-care screening for neonatal hypoglycaemia. © 2018 S. Karger AG, Basel.

  10. Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks

    PubMed Central

    Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.

    2009-01-01

    Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815

  11. Cross-reactivity profiles of hybrid capture II, cobas, and APTIMA human papillomavirus assays: split-sample study.

    PubMed

    Preisler, Sarah; Rebolj, Matejka; Ejegod, Ditte Møller; Lynge, Elsebeth; Rygaard, Carsten; Bonde, Jesper

    2016-07-20

    High-risk Human Papillomavirus (HPV) testing is replacing cytology in cervical cancer screening as it is more sensitive for preinvasive cervical lesions. However, the bottleneck of HPV testing is the many false positive test results (positive tests without cervical lesions). Here, we evaluated to what extent these can be explained by cross-reactivity, i.e. positive test results without evidence of high-risk HPV genotypes. The patterns of cross-reactivity have been thoroughly studied for hybrid capture II (HC2) but not yet for newer HPV assays although the manufacturers claimed no or limited frequency of cross-reactivity. In this independent study we evaluated the frequency of cross-reactivity for HC2, cobas, and APTIMA assays. Consecutive routine cervical screening samples from 5022 Danish women, including 2859 from women attending primary screening, were tested with the three evaluated DNA and mRNA HPV assays. Genotyping was undertaken using CLART HPV2 assay, individually detecting 35 genotypes. The presence or absence of cervical lesions was determined with histological examinations; women with abnormal cytology were managed as per routine recommendations; those with normal cytology and positive high-risk HPV test results were invited for repeated testing in 18 months. Cross-reactivity to low-risk genotypes was detected in 109 (2.2 %) out of 5022 samples on HC2, 62 (1.2 %) on cobas, and 35 (0.7 %) on APTIMA with only 10 of the samples cross-reacting on all 3 assays. None of the 35 genotypes was detected in 49 (1.0 %), 162 (3.2 %), and 56 (1.1 %) samples, respectively. In primary screening at age 30 to 65 years (n = 2859), samples of 72 (25 %) out of 289 with high-risk infections on HC2 and < CIN2 histology were due to cross-reactivity. On cobas, this was 106 (26 %) out of 415, and on APTIMA 48 (21 %) out of 224. Despite manufacturer claims, all three assays showed cross-reactivity. In primary cervical screening at age ≥30 years, cross-reactivity accounted for about one quarter of false positive test results regardless of the assay. Cross-reactivity should be addressed in EU tenders, as this primarily technical shortcoming imposes additional costs on the screening programmes.

  12. Development of a language screening instrument for Swedish 4-year-olds.

    PubMed

    Lavesson, Ann; Lövdén, Martin; Hansson, Kristina

    2018-05-01

    The Swedish Program for health surveillance of preschool children includes screening of language and communication abilities. One important language screening is carried out at age 4 years as part of a general screening conducted by health nurses at child health centres. The instruments presently in use for this screening mainly focus on expressive phonology. This may result in both over-referral of children with phonological difficulties and under-referral of children with language disorders (LDs), involving difficulties with vocabulary, grammar and/or language comprehension. Previous research has proposed non-word repetition as a clinical marker for LD. It has also been found that higher predictive power is achieved when non-word repetition is combined with the assessment of lexical/semantic skills. Taking these findings into account, the construction of a language screening instrument may yield more adequate referrals to speech-language therapists (SLTs). To construct a new standardized language screening instrument for 4-year-olds and to test its properties. An instrument was developed and revised after piloting. A population of 352 children was screened at the regular 4-year check-up by 11 health nurses. The final sample consisted of 328 children aged 46-53 months (23% multilingual). Children performing below a preliminary cut-off were referred to an SLT (n = 52). Five SLTs carried out an assessment on average within 5 weeks using a gold standard language test battery. Children who screened negatively were followed up with a parent questionnaire at age 5;6. Thirty-one true-positives and 11 false-positives were identified after SLT assessment. A further six children were identified as false-negatives (two through referral to an SLT and four through parent questionnaire at age 5;6). A receiver-operating characteristics curve with a C statistic of .94 was calculated. Based on optimal cut-off, the sensitivity of the screening instrument was found to be .84, and specificity was .96. Multilingual children performed similar to monolingual children; boys performed significantly lower than girls; and children with a family history of language-related problems performed lower than those without. Interrater reliability was high, as was Cronbach's alpha. The screening instrument seems sufficiently valid for its purpose to identify children who need further assessment by an SLT. A follow-up study including SLT assessment for all children to check for false-negatives would be interesting in future, as would studies comparing results from the 4-year screening with those from earlier screens. © 2018 Royal College of Speech and Language Therapists.

  13. Application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in the screening of vanA-positive Enterococcus faecium.

    PubMed

    Wang, Li-jun; Lu, Xin-xin; Wu, Wei; Sui, Wen-jun; Zhang, Gui

    2014-01-01

    In order to evaluate a rapid matrix-assisted laser desorption ionization-time of flight mass spectrometry (MAIDI-TOF MS) assay in screening vancomycin-resistant Enterococcus faecium, a total of 150 E. faecium clinical strains were studied, including 60 vancomycin-resistant E. faecium (VREF) isolates and 90 vancomycin-susceptible (VSEF) strains. Vancomycin resistance genes were detected by sequencing. E. faecium were identified by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was generated using spectra of 30 VREF isolates and 30 VSEF isolates. Using this model, 90 test isolates were discriminated between VREF and VSEF. The results showed that all sixty VREF isolates carried the vanA gene. The performance of VREF detection by the genetic algorithm model of MALDI-TOF MS compared to the sequencing method was sensitivity = 80%, specificity = 90%, false positive rate =10%, false negative rate =10%, positive predictive value = 80%, negative predictive value= 90%. MALDI-TOF MS can be used as a screening test for discrimination between vanA-positive E. faecium and vanA-negative E. faecium.

  14. Scheme for the selection of measurement uncertainty models in blood establishments' screening immunoassays.

    PubMed

    Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda

    2015-02-01

    Blood establishments routinely perform screening immunoassays to assess safety of the blood components. As with any other screening test, results have an inherent uncertainty. In blood establishments the major concern is the chance of false negatives, due to its possible impact on patients' health. This article briefly reviews GUM and diagnostic accuracy models for screening immunoassays, recommending a scheme to support the screening laboratories' staffs on the selection of a model considering the intended use of the screening results (i.e., post-transfusion safety). The discussion is grounded on a "risk-based thinking", risk being considered from the blood donor selection to the screening immunoassays. A combination of GUM and diagnostic accuracy models to evaluate measurement uncertainty in blood establishments is recommended. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. First and second trimester serum tests with and without first trimester ultrasound tests for Down's syndrome screening.

    PubMed

    Alldred, S Kate; Takwoingi, Yemisi; Guo, Boliang; Pennant, Mary; Deeks, Jonathan J; Neilson, James P; Alfirevic, Zarko

    2017-03-15

    Down's syndrome occurs when a person has three copies of chromosome 21 (or the specific area of chromosome 21 implicated in causing Down's syndrome) rather than two. It is the commonest congenital cause of mental disability. Non-invasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing.  Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal) and false negative screening tests (i.e. a fetus with Down's syndrome will be missed). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. To estimate and compare the accuracy of first and second trimester serum markers with and without first trimester ultrasound markers for the detection of Down's syndrome in the antenatal period, as combinations of markers. We conducted a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), Embase (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), the Database of Abstracts of Reviews of Effectiveness (the Cochrane Library 25 August 2011), MEDION (25 August 2011), the Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), the National Research Register (Archived 2007), and Health Services Research Projects in Progress database (25 August 2011). We did not apply a diagnostic test search filter. We did forward citation searching in ISI citation indices, Google Scholar and PubMed 'related articles'. We also searched reference lists of retrieved articles SELECTION CRITERIA: Studies evaluating tests of combining first and second trimester maternal serum markers in women up to 24 weeks of gestation for Down's syndrome, with or without first trimester ultrasound markers, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. Data were extracted as test positive/test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS criteria. We used hierarchical summary ROC meta-analytical methods to analyse test performance and compare test accuracy. Analysis of studies allowing direct comparison between tests was undertaken. We investigated the impact of maternal age on test performance in subgroup analyses. Twenty-two studies (reported in 25 publications) involving 228,615 pregnancies (including 1067 with Down's syndrome) were included. Studies were generally high quality, although differential verification was common with invasive testing of only high risk pregnancies. Ten studies made direct comparisons between tests. Thirty-two different test combinations were evaluated formed from combinations of eight different tests and maternal age; first trimester nuchal translucency (NT) and the serum markers AFP, uE3, total hCG, free βhCG, Inhibin A, PAPP-A and ADAM 12. We looked at tests combining first and second trimester markers with or without ultrasound as complete tests, and we also examined stepwise and contingent strategies.Meta-analysis of the six most frequently evaluated test combinations showed that a test strategy involving maternal age and a combination of first trimester NT and PAPP-A, and second trimester total hCG, uE3, AFP and Inhibin A significantly outperformed other test combinations that involved only one serum marker or NT in the first trimester, detecting about nine out of every 10 Down's syndrome pregnancies at a 5% false positive rate. However, the evidence was limited in terms of the number of studies evaluating this strategy, and we therefore cannot recommend one single screening strategy. Tests involving first trimester ultrasound with first and second trimester serum markers in combination with maternal age are significantly better than those without ultrasound, or those evaluating first trimester ultrasound in combination with second trimester serum markers, without first trimester serum markers. We cannot make recommendations about a specific strategy on the basis of the small number of studies available.

  16. The health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study.

    PubMed

    Karaceper, Maria D; Chakraborty, Pranesh; Coyle, Doug; Wilson, Kumanan; Kronick, Jonathan B; Hawken, Steven; Davies, Christine; Brownell, Marni; Dodds, Linda; Feigenbaum, Annette; Fell, Deshayne B; Grosse, Scott D; Guttmann, Astrid; Laberge, Anne-Marie; Mhanni, Aizeddin; Miller, Fiona A; Mitchell, John J; Nakhla, Meranda; Prasad, Chitra; Rockman-Greenberg, Cheryl; Sparkes, Rebecca; Wilson, Brenda J; Potter, Beth K

    2016-02-03

    There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.

  17. A Modified Protocol for Color Vision Screening Using Ishihara.

    PubMed

    Chorley, Adrian C

    2015-08-01

    The Ishihara plates are commonly used as an initial occupational screening test for color vision. While effective at detecting red-green deficiencies, the color deficient subject can learn the test using different techniques. Some medical standards such as the European Aviation Safety Agency (EASA) require plate randomization and apply a stricter pass/fail requirement than suggested by Ishihara. This has been reported to increase the false positive rate up to ∼50%. Two modifications to the Ishihara protocol are investigated. These involved allowing subjects a second attempt where one or two reading errors were made and the presentation of rotated Ishihara plates. A reduction of false positive rate to 5.9% was found. Correct identification of certain rotated Ishihara plates was not affected. By using a modified Ishihara protocol, fewer color normal subjects would require unnecessary advanced color vision examination. Further, additional safeguards would be in place to ensure that no subject with a color vision deficiency could pass the Ishihara test.

  18. Expanded newborn metabolic screening programme in Hong Kong: a three-year journey.

    PubMed

    Chong, S C; Law, L K; Hui, J; Lai, C Y; Leung, T Y; Yuen, Y P

    2017-10-01

    No universal expanded newborn screening service for inborn errors of metabolism is available in Hong Kong despite its long history in developed western countries and rapid development in neighbouring Asian countries. To increase the local awareness and preparedness, the Centre of Inborn Errors of Metabolism of the Chinese University of Hong Kong started a private inborn errors of metabolism screening programme in July 2013. This study aimed to describe the results and implementation of this screening programme. We retrieved the demographics of the screened newborns and the screening results from July 2013 to July 2016. These data were used to calculate quality metrics such as call-back rate and false-positive rate. Clinical details of true-positive and false-negative cases and their outcomes were described. Finally, the call-back logistics for newborns with positive screening results were reviewed. During the study period, 30 448 newborns referred from 13 private and public units were screened. Of the samples, 98.3% were collected within 7 days of life. The overall call-back rate was 0.128% (39/30 448) and the false-positive rate was 0.105% (32/30 448). Six neonates were confirmed to have inborn errors of metabolism, including two cases of medium-chain acyl-coenzyme A dehydrogenase deficiency, one case of carnitine-acylcarnitine translocase deficiency, and three milder conditions. One case of maternal carnitine uptake defect was diagnosed. All patients remained asymptomatic at their last follow-up. The Centre of Inborn Errors of Metabolism has established a comprehensive expanded newborn screening programme for selected inborn errors of metabolism. It sets a standard against which the performance of other private newborn screening tests can be compared. Our experience can also serve as a reference for policymakers when they contemplate establishing a government-funded universal expanded newborn screening programme in the future.

  19. Presymptomatic Diagnosis of Spinal Muscular Atrophy Through Newborn Screening.

    PubMed

    Chien, Yin-Hsiu; Chiang, Shu-Chuan; Weng, Wen-Chin; Lee, Ni-Chung; Lin, Ching-Jie; Hsieh, Wu-Shiun; Lee, Wang-Tso; Jong, Yuh-Jyh; Ko, Tsang-Ming; Hwu, Wuh-Liang

    2017-11-01

    To demonstrate the feasibility of presymptomatic diagnosis of spinal muscular atrophy (SMA) through newborn screening (NBS). We performed a screening trial to assess all newborns who underwent routine newborn metabolic screening at the National Taiwan University Hospital newborn screening center between November 2014 and September 2016. A real-time polymerase chain reaction (RT-PCR) genotyping assay for the SMN1/SMN2 intron 7 c.888+100A/G polymorphism was performed to detect homozygous SMN1 deletion using dried blood spot (DBS) samples. Then the exon 7 c.840C>T mutation and SMN2 copy number were determined by both droplet digital PCR (ddPCR) using the original screening DBS and multiplex ligation-dependent probe amplification (MLPA) using a whole blood sample. Of the 120 267 newborns, 15 tested positive according to the RT-PCR assay. The DBS ddPCR assay excluded 8 false-positives, and the other 7 patients were confirmed by the MLPA assay. Inclusion of the second-tier DBS ddPCR screening assay resulted in a positive prediction value of 100%. The incidence of SMA was 1 in 17 181 (95% CI, 1 in 8323 to 1 in 35 468). Two of the 3 patients with 2 copies of SMN2 and all 4 patients with 3 or 4 copies of SMN2 were asymptomatic at the time of diagnosis. Five of the 8 false-positives were caused by intragenic recombination between SMN1 and SMN2. Newborn screening can detect patients affected by SMA before symptom onset and enable early therapeutic intervention. A combination of a RT-PCR and a second-tier ddPCR can accurately diagnose SMA from DBS samples with no false-positives. ClinicalTrials.gov NCT02123186. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Quantitative assessment of hit detection and confirmation in single and duplicate high-throughput screenings.

    PubMed

    Wu, Zhijin; Liu, Dongmei; Sui, Yunxia

    2008-02-01

    The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.

  1. Comprehensive Mechanistic Analysis of Hits from High-Throughput and Docking Screens against β-Lactamase

    PubMed Central

    Babaoglu, Kerim; Simeonov, Anton; Irwin, John J.; Nelson, Michael E.; Feng, Brian; Thomas, Craig J.; Cancian, Laura; Costi, M. Paola; Maltby, David A.; Jadhav, Ajit; Inglese, James; Austin, Christopher P.; Shoichet, Brian K.

    2009-01-01

    High-throughput screening (HTS) is widely used in drug discovery. Especially for screens of unbiased libraries, false positives can dominate “hit lists”; their origins are much debated. Here we determine the mechanism of every active hit from a screen of 70,563 unbiased molecules against β-lactamase using quantitative HTS (qHTS). Of the 1274 initial inhibitors, 95% were detergent-sensitive and were classified as aggregators. Among the 70 remaining were 25 potent, covalent-acting β-lactams. Mass spectra, counter-screens, and crystallography identified 12 as promiscuous covalent inhibitors. The remaining 33 were either aggregators or irreproducible. No specific reversible inhibitors were found. We turned to molecular docking to prioritize molecules from the same library for testing at higher concentrations. Of 16 tested, 2 were modest inhibitors. Subsequent X-ray structures corresponded to the docking prediction. Analog synthesis improved affinity to 8 µM. These results suggest that it may be the physical behavior of organic molecules, not their reactivity, that accounts for most screening artifacts. Structure-based methods may prioritize weak-but-novel chemotypes in unbiased library screens. PMID:18333608

  2. Sequencing from dried blood spots in infants with "false positive" newborn screen for MCAD deficiency.

    PubMed

    McCandless, Shawn E; Chandrasekar, Ram; Linard, Sharon; Kikano, Sandra; Rice, Lorrie

    2013-01-01

    Newborn screening (NBS) for medium chain acyl-CoA dehydrogenase deficiency (MCADD), one of the most common disorders identified, uses measurement of octanoylcarnitine (C8) from dried blood spots. In the state of Ohio, as in many places, primary care providers, with or without consultation from a metabolic specialist, may perform "confirmatory testing", with the final diagnostic decision returned to the state. Confirmatory testing may involve measurement of metabolites, enzyme analysis, mutation screening, or sequencing. We now report sequencing results for infants said to have "false positive" NBS results for MCAD deficiency, or who died before confirmatory testing could be performed. Dried blood spots (DBS) were obtained from all 18 available NBS cards identified as "false positive" by NBS for the 3 year period after screening began in Ohio in 2003 (N=20, thus 2 had no DBS available), and from all 6 infants with abnormal screens who died before confirmatory testing could be obtained. DNA extracted from DBS was screened for the common c.985A>G mutation in exon 11 of the ACADM gene, using a specific restriction digest method, followed by sequencing of the 12 exons, intron-exon junctions, and several hundred base pairs of the 5' untranslated region. The NBS cut-off value for C8 used was 0.7 μmol/L. Sequencing of ACADM in six neonates with elevated C8 on NBS who died before confirmatory testing was obtained did not identify any significant variants in the coding region of the gene, suggesting that MCADD was not a contributing factor in these deaths. The mean C8 for the 18 surviving infants labeled as "False Positives" was 0.90 (95%CI 0.77-1.15), much lower than the mean value for confirmed cases. Ten of the 18 were premature births weighing <1200 g, the rest were normal sized and full term. Eight infants, mostly full term with appropriate birth weight, were heterozygous for the common c.985A>G mutation; one of those also has a novel sequence change identified in exon 9 that predicts a PRO to LEU change at residue 258 of the protein. Both the phase and any possible clinical significance of the variant are unknown, but several lines of evidence suggest that it could lead to protein malfunction. That child had an NBS C8 of 2.2, more than double the mean for the False Positive group. Unfortunately, the study design did not provide clinical outcome data, but the child is not known to have presented clinically by age 7 years. These results suggest that sequencing of ACADM from dried blood spots can be one useful follow-up tool to provide accurate genetic counseling in the situation of an infant with elevated C8 on NBS who dies before confirmatory testing is obtained. Of surviving neonates, there appear to be two populations of infants with false positive NBS C8 values: 1) term AGA infants who are heterozygous for the common c.985A>G mutation, and, 2) premature infants, regardless of carrier status. The finding of two sequence variants in an infant reported to the state as not affected suggests the possibility that some infants with two mutations may be reported as normal at follow-up. State registries may wish to consider asking that metabolic specialists, who are most familiar with the variability of these rare disorders, be involved in the final diagnostic evaluation. Finally, providers may wish to consider ACADM sequencing, or other diagnostic testing, as part of the confirmatory evaluation for infants with NBS C8 concentrations that are significantly above the cut-off value, even if plasma and urine metabolites are not strikingly increased. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. The ethics of screening: is 'screeningitis' an incurable disease?

    PubMed Central

    Shickle, D; Chadwick, R

    1994-01-01

    Screening programmes are becoming increasingly popular since prevention is considered 'better than cure'. While earlier diagnosis may result in more effective treatment for some, there will be consequent harm for others due to anxiety, stigma, side-effects etc. A screening test cannot guarantee the detection of all 'abnormal' cases, therefore there will be false reassurance for some. A proper consideration of the potential benefit and harm arising from screening may lead to the conclusion that the programme should not be offered. A modified utilitarian approach may be used for allocation of scarce resources in health care. Ethics has an important role in this evaluation. PMID:8035433

  4. The development and testing of a brief ('gist-based') supplementary colorectal cancer screening information leaflet.

    PubMed

    Smith, Samuel G; Wolf, Michael S; Obichere, Austin; Raine, Rosalind; Wardle, Jane; von Wagner, Christian

    2013-12-01

    To design and user-test a 'gist-based' colorectal cancer screening information leaflet, which promotes comprehension of the screening offer. Twenty-eight individuals approaching screening age were recruited from organisations in deprived areas of England. Using a between-subjects design, we tested iterations of a newly-designed gist-based information leaflet. Participants read the leaflet and answered 8 'true' or 'false' comprehension statements. For the leaflet to be considered fit-for-purpose, all statements had to be answered correctly by at least 80% of participants in each round. Alterations were made if this threshold was not met and additional rounds of testing were undertaken. At round 1, answers to 2/8 statements did not meet the threshold. After changes, answers in round 2 did not reach the threshold for 1/8 statements. In round 3, all answers were adequate and the leaflet was deemed fit-for-purpose. Qualitative data offered solutions such as language and layout changes which led to improved comprehension of the leaflet. User-testing substantially improved the design and subsequent comprehensibility of a theory-driven gist-based colorectal cancer screening information leaflet. This leaflet will be evaluated as part of a large national randomised controlled trial designed to reduce socioeconomic inequalities in colorectal cancer screening participation. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  5. Changing perspectives in screening for congenital hypothyroidism and congenital adrenal hyperplasia.

    PubMed

    Mitchell, Marvin L; Hsu, Ho-Wen; Sahai, Inderneel

    2014-02-01

    The purpose of this review is to summarize recent information that has had a significant impact on the laboratory diagnosis and clinical management of newborns with congenital hypothyroidism and congenital adrenal hyperplasia (CAH). An approximate doubling of the incidence rate of congenital hypothyroidism in many parts of the world has been attributed to increased detection of infants with mild disease, delayed thyroid stimulating hormone elevations and demographic changes. A substantial number of children with modest thyroid stimulating hormone elevations on screening have permanent disease. Circulating levels of thyroxine may vary among hypothyroid children who are given identical dosages of medication. Treated infants should be monitored every 1-2 months during the first year of life. Although, generic and brand name thyroxine preparations may not be bioequivalent, children can be well controlled on generic formulations.Enzyme linked immunoassay assay for 17-hydroxyprogesterone is associated with a high rate of false positive specimens. In attempts to minimize this problem, some programs have resorted to two-tier screening of the initial specimen with steroid profiling as the second tier. Several programs are routinely testing second specimens in an effort to reduce the incidence of missed CAH cases. This review explains the uptick in incidence rate of congenital hypothyroidism and underscores issues in management that can affect developmental outcome. One specimen two-tier testing for CAH resulted in an increased false negative rate without significantly reducing the false positive rate. The benefit of collecting second specimens for CAH screening is problematic. Optimal treatment of CAH continues to pose a challenge.

  6. Noninvasive prenatal testing in routine clinical practice--an audit of NIPT and combined first-trimester screening in an unselected Australian population.

    PubMed

    McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus

    2016-02-01

    There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  7. Experience using the «Shetty test» for initial foot and ankle fracture screening in the Emergency Department.

    PubMed

    Ojeda-Jiménez, J; Méndez-Ojeda, M M; Martín-Vélez, P; Tejero-García, S; Pais-Brito, J L; Herrera-Pérez, M

    2018-03-20

    The indiscriminate practice of radiographs for foot and ankle injuries is not justified and numerous studies have corroborated the usefulness of clinical screening tests such as the Ottawa Ankle Rules. The aim of our study is to clinically validate the so-called Shetty Test in our area. A cross-sectional observational study by applying the Shetty test to patients seen in the Emergency Department. We enrolled 100 patients with an average age of 39.25 (16-86). The Shetty test was positive on 14 occasions. Subsequent radiography revealed a fracture in 10 cases: 4 were false positives. The test was negative in the remaining 86 patients and radiography confirmed the absence of fracture (with sensitivity of 100% and specificity of 95.56%, positive predictive value of 71.40%, and negative predictive value of 100%). The Shetty test is a valid clinical screening tool to decide whether simple radiography is indicated for foot and ankle injuries. It is a simple, quick and reproducible test. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.

    PubMed

    Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S

    2012-01-01

    Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.

  9. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    PubMed

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P < .01) and grade I tumors (13.2% [147 of 1114] vs 42.9% [six of 14]; P < .01), but a higher proportion of cases with lymph nodes positive for cancer (40.9% [442 of 1080] vs 13.3% [two of 15], respectively; P = .03) compared with women with a previous false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  10. Differences in tuberculin reactivity as determined in a veterans administration employee health screening program.

    PubMed

    Mehta, Sanjay R; MacGruder, Cathy; Looney, David; Johns, Scott; Smith, Davey M

    2009-04-01

    In response to a difference in pricing, the San Diego Veterans Administration Medical Center changed its tuberculin preparation from Tubersol to Aplisol in the fall of 2006. Following the change, an increased number of employee skin test conversions was noted. Employee tuberculin skin test converters from 2006 were screened with the QuantiFERON Gold (QFT-G) gamma interferon release assay. Those employees who tested negative by QFT-G were asked to repeat their skin test with both Tubersol and Aplisol tuberculin preparations. Of the new purified protein derivative converters, 12 of 14 returned for repeat testing with QFT-G, and the assay was negative for 83% (10/12), positive for 8% (1/12), and indeterminate for 8% (1/12) of the individuals. Nine of the individuals who were QFT-G negative agreed to repeat skin testing with both tuberculin preparations, and 7/8 (87.5%) demonstrated reactivity with the Aplisol preparation, while 0/8 (0%) reacted to the Tubersol preparation. A change from Tubersol to Aplisol resulted in elevated tuberculin skin test conversion rates that may be due to false-positive reactions. The differences in skin test reactivity between preparations support CDC guidelines that recommend that institutions should not change tuberculin preparations, as doing so may falsely increase the number of positive reactions.

  11. Biologic therapy and screening for tuberculosis in a new service.

    PubMed

    Peters, Julie

    Plaque psoriasis is a common skin condition that can greatly affect quality of life. Biologic therapy is an effective treatment, but it poses risks to patients, particularly concerning latent infections such as tuberculosis (TB), which may be reactivated. Medical practitioners therefore need to screen patients before commencing a biologic therapy. There are a number of screening tools for TB infection, which vary in efficacy depending on the patient being screened, and some tests can give a false-negative result for TB infection. It is important to screen for TB and to take a good clinical and lifestyle history before commencing biologic treatment. This article discusses the above in the context of setting up a dedicated clinic to monitor patients on biologic therapy for plaque psoriasis.

  12. Maternal biochemical serum screening for Down syndrome in pregnancy with human immunodeficiency virus infection.

    PubMed

    Le Meaux, Jean-Patrick; Tsatsaris, Vassilis; Schmitz, Thomas; Fulla, Yvonne; Launay, Odile; Goffinet, François; Azria, Elie

    2008-08-01

    To estimate the influence of human immunodeficiency virus (HIV) infection and antiretroviral therapy on maternal serum markers levels and the false-positive rate with biochemical maternal serum screening for Down syndrome. We performed a 1:1 matched case-control study comparing 132 HIV-infected women with single pregnancy to controls selected among non-HIV-infected women matched on geographical origin and fetal sex. Of HIV-infected women, 47.7% were receiving antiretroviral therapy. Groups did not differ in multiples of the median (MoM) levels of total human chorionic gonadotrophin. The MoM alpha fetoprotein level did not differ between total HIV-infected women and control women but was significantly lower for untreated HIV-positive women compared with control women (0.91 compared with 1.03 MoM, P<.01) and compared with treated HIV-positive women (0.91 compared with 1.18 MoM, P<.01). The false-positive rate of biochemical screening did not differ between groups. Untreated HIV infection is associated with lower maternal serum alpha fetoprotein levels. Nevertheless, the false-positive rate of double-marker second-trimester Down syndrome serum screening did not appear to be affected in our sample of HIV-infected women, whether women were receiving antiretroviral therapy at the time of the test or not.

  13. [Prospective performance evaluation of first trimester screenings in Germany for risk calculation through http://www.firsttrimester.net].

    PubMed

    Kleinsorge, F; Smetanay, K; Rom, J; Hörmansdörfer, C; Hörmannsdörfer, C; Scharf, A; Schmidt, P

    2010-12-01

    In 2008, 2 351 first trimester screenings were calculated by a newly developed internet database ( http:// www.firsttrimester.net ) to evaluate the risk for the presence of Down's syndrome. All data were evaluated by the conventional first trimester screening according to Nicolaides (FTS), based on the previous JOY Software, and by the advanced first trimester screening (AFS). After receiving the feedback of the karyotype as well as the rates of the correct positives, correct negatives, false positives, false negatives, the sensitivity and specificity were calculated and compared. Overall 255 cases were investigated which were analysed by both methods. These included 2 cases of Down's syndrome and one case of trisomy 18. The FTS and the AFS had a sensitivity of 100%. The specificity was 88.5% for the FTS and 93.0% for the AFS. As already shown in former studies, the higher specificity of the AFS is a result of a reduction of the false positive rate (28 to 17 cases). As a consequence of the AFS with a detection rate of 100% the rate of further invasive diagnostics in pregnant women is decreased by having 39% fewer positive tested women. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    PubMed

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  15. Opt-out of voluntary HIV testing: a Singapore hospital's experience.

    PubMed

    Chua, Arlene C; Leo, Yee Sin; Cavailler, Philippe; Chu, Christine; Ng, Aloysius; Ng, Oon Tek; Krishnan, Prabha

    2012-01-01

    Since 2008, the Singapore Ministry of Health (MOH) has expanded HIV testing by increasing anonymous HIV test sites, as well as issuing a directive to hospitals to offer routine voluntary opt out inpatient HIV testing. We reviewed this program implemented at the end of 2008 at Tan Tock Seng Hospital (TTSH), the second largest acute care general hospital in Singapore. From January 2009 to December 2010, all inpatients aged greater or equal than 21 years were screened for HIV unless they declined or were not eligible for screening. We reviewed the implementation of the Opt Out testing policy. There were a total of 93,211 admissions; 41,543 patients were included based on HIV screening program eligibility criteria. Among those included, 79% (n = 32,675) opted out of HIV screening. The overall acceptance rate was 21%. Majority of eligible patients who were tested (63%) were men. The mean age of tested patients was 52 years. The opt out rate was significantly higher among females (OR: 1.5, 95%CI: 1.4-1.6), aged >60 years (OR: 2.3, 95%CI: 2.2-2.4) and Chinese ethnicity (OR: 1.7, 95%CI:1.6-1.8). The false positive rate of the HIV screening test is 0.56%. The proportion of patients with HIV infection among those who underwent HIV screening is 0.18%. All 16 confirmed HIV patients were linked to care. The default opt-in rate of inpatient HIV testing was low at Tan Tock Seng Hospital, Singapore. Efforts to address individual HIV risk perception and campaigns against HIV stigma are needed to encourage more individuals to be tested for HIV.

  16. Opt-out of Voluntary HIV Testing: A Singapore Hospital's Experience

    PubMed Central

    Chua, Arlene C.; Leo, Yee Sin; Cavailler, Philippe; Chu, Christine; Ng, Aloysius; Ng, Oon Tek; Krishnan, Prabha

    2012-01-01

    Introduction Since 2008, the Singapore Ministry of Health (MOH) has expanded HIV testing by increasing anonymous HIV test sites, as well as issuing a directive to hospitals to offer routine voluntary opt out inpatient HIV testing. We reviewed this program implemented at the end of 2008 at Tan Tock Seng Hospital (TTSH), the second largest acute care general hospital in Singapore. Methods and Findings From January 2009 to December 2010, all inpatients aged greater or equal than 21 years were screened for HIV unless they declined or were not eligible for screening. We reviewed the implementation of the Opt Out testing policy. There were a total of 93,211 admissions; 41,543 patients were included based on HIV screening program eligibility criteria. Among those included, 79% (n = 32,675) opted out of HIV screening. The overall acceptance rate was 21%. Majority of eligible patients who were tested (63%) were men. The mean age of tested patients was 52 years. The opt out rate was significantly higher among females (OR: 1.5, 95%CI: 1.4–1.6), aged >60 years (OR: 2.3, 95%CI: 2.2–2.4) and Chinese ethnicity (OR: 1.7, 95%CI:1.6–1.8). The false positive rate of the HIV screening test is 0.56%. The proportion of patients with HIV infection among those who underwent HIV screening is 0.18%. All16 confirmed HIV patients were linked to care. Conclusion The default opt-in rate of inpatient HIV testing was low at Tan Tock Seng Hospital, Singapore. Efforts to address individual HIV risk perception and campaigns against HIV stigma are needed to encourage more individuals to be tested for HIV. PMID:22493708

  17. Comparison of fecal occult blood tests for colorectal cancer screening in an Alaska Native population with high prevalence of Helicobacter pylori infection, 2008-2012.

    PubMed

    Redwood, Diana; Provost, Ellen; Asay, Elvin; Roberts, Diana; Haverkamp, Donald; Perdue, David; Bruce, Michael G; Sacco, Frank; Espey, David

    2014-04-10

    Alaska Native colorectal cancer (CRC) incidence and mortality rates are the highest of any ethnic/racial group in the United States. CRC screening using guaiac-based fecal occult blood tests (gFOBT) are not recommended for Alaska Native people because of false-positive results associated with a high prevalence of Helicobacter pylori-associated hemorrhagic gastritis. This study evaluated whether the newer immunochemical FOBT (iFOBT) resulted in a lower false-positive rate and higher specificity for detecting advanced colorectal neoplasia than gFOBT in a population with elevated prevalence of H. pylori infection. We used a population-based sample of 304 asymptomatic Alaska Native adults aged 40 years or older undergoing screening or surveillance colonoscopy (April 2008-January 2012). Specificity differed significantly (P < .001) between gFOBT (76%; 95% CI, 71%-81%) and iFOBT (92%; 95% CI, 89%-96%). Among H. pylori-positive participants (54%), specificity of iFOBT was even higher (93% vs 69%). Overall, sensitivity did not differ significantly (P = .73) between gFOBT (29%) and iFOBT (36%). Positive predictive value was 11% for gFOBT and 32% for iFOBT. The iFOBT had a significantly higher specificity than gFOBT, especially in participants with current H. pylori infection. The iFOBT represents a potential strategy for expanding CRC screening among Alaska Native and other populations with elevated prevalence of H. pylori, especially where access to screening endoscopy is limited.

  18. Assessing the improvements in the newborn screening strategy for cystic fibrosis in the Balearic Islands.

    PubMed

    Bauça, Josep Miquel; Morell-Garcia, Daniel; Vila, Magdalena; Pérez, Gerardo; Heine-Suñer, Damián; Figuerola, Joan

    2015-04-01

    Newborn screening strategies for cystic fibrosis (CF) are run worldwide, and aim at the early detection of the disorder to significantly improve the quality of life. Elevated levels of immunoreactive trypsinogen (IRT) represent a high likelihood for the screened child to be affected with CF. However, the specificity of IRT is low. The objective of this study was to assess the screening program in the Balearic Islands during the past 14 years. We evaluated all results of the screening program after 14 years, by considering all changes in the protocol and assessing the number of positive samples, the mutations detected, the number of sweat tests performed, the incidence of CF and the presence of false-negative cases. Despite a great variability among the different Balearic Islands, the global incidence of CF was 1:6059 for the 14 years assessed. The incidence in the smaller islands is about 5 times higher than in Majorca (1:2376 versus 1:10,613). After different changes in the protocol, an IRT cut-off value of 60 ng/mL was established. The two most common mutations are ΔF508 and G542X, in accordance with other geographical regions. The changes in the protocol helped reduce the number of sweat tests performed without any increase in the false-negative rate. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Cushing's Syndrome: Screening and Diagnosis.

    PubMed

    Ceccato, Filippo; Boscaro, Marco

    2016-09-01

    Endogenous Cushing's syndrome (CS) is a rare disease, and usually characterized by hypertension, diabetes, obesity, osteoporosis, facial rounding, dorsocervical fat pad, thin skin, purple striae, hirsutism, and mood disorders. Efficient diagnostic and screening strategies lead to the diagnosis of a significantly higher number of cases of CS. As a screening test for CS, the Endocrine Society's Clinical Practice Guidelines recommend a single test with a high diagnostic accuracy, among the 1-mg dexamethasone suppression test (1-mg DST), late night salivary cortisol (LNSC), and 24 h urinary free cortisol (UFC). In normal subjects, administering a higher than physiological dose of glucocorticoids prompts the suppression of cortisol secretion. The 1-mg DST explores this normal feedback reaction from the hypothalamic-pituitary-adrenal axis (HPA). It is a simple dynamic test, usually performed in outpatients. A morning serum cortisol level <50 nmol/L suffices to exclude CS, unless there is a strong clinical suspicion to suggest otherwise. The HPA axis reaches a nadir just after a person has fallen asleep, but its circadian rhythm is impaired in CS patients, who feature higher cortisol values at night, which are easy to measure in saliva (the LNSC assay). Saliva collection is also suitable for outpatients since cortisol is stable at room temperature and the collection device can be mailed to the laboratory for analysis. UFC levels reflect the integrated tissue exposure to free cortisol over 24 h, and thus provide a particular picture of endogenous hypercortisolism. In most cases, high UFC levels coincide with severe hypercortisolism. UFC is used not only to diagnose CS, but also to monitor its response to medical treatment. All screening tests have procedural snares: some drugs can interfere with the DST; false-positive or false-negative LNSC results may be due to an inadequate soaking of the device or to cyclic CS; and in the case of UFC it is important to ensure that patients provide complete urine collections with appropriate total volumes. Measuring cortisol with antibody-based immunoassays can also generate false-positive results due to cross-reactivity between cortisol, cortisone and other metabolites. Structurally-based assays, such as liquid chromatography with tandem mass spectrometry, only measure cortisol and have only recently become available for use in routine clinical practice. This review summarizes the recent literature on the clinical and biochemical aspects of CS diagnostics with a view to helping physicians choose the best screening test for diagnosing endogenous hypercortisolism.

  20. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    PubMed

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  1. Introducing Bayesian thinking to high-throughput screening for false-negative rate estimation.

    PubMed

    Wei, Xin; Gao, Lin; Zhang, Xiaolei; Qian, Hong; Rowan, Karen; Mark, David; Peng, Zhengwei; Huang, Kuo-Sen

    2013-10-01

    High-throughput screening (HTS) has been widely used to identify active compounds (hits) that bind to biological targets. Because of cost concerns, the comprehensive screening of millions of compounds is typically conducted without replication. Real hits that fail to exhibit measurable activity in the primary screen due to random experimental errors will be lost as false-negatives. Conceivably, the projected false-negative rate is a parameter that reflects screening quality. Furthermore, it can be used to guide the selection of optimal numbers of compounds for hit confirmation. Therefore, a method that predicts false-negative rates from the primary screening data is extremely valuable. In this article, we describe the implementation of a pilot screen on a representative fraction (1%) of the screening library in order to obtain information about assay variability as well as a preliminary hit activity distribution profile. Using this training data set, we then developed an algorithm based on Bayesian logic and Monte Carlo simulation to estimate the number of true active compounds and potential missed hits from the full library screen. We have applied this strategy to five screening projects. The results demonstrate that this method produces useful predictions on the numbers of false negatives.

  2. Heterotypic antibodies in Liberian sera causing anomalous reactions when using a commercial haemagglutination test for hepatitis-B surface antigen.

    PubMed

    Willcox, M C

    1976-04-01

    Agglutinins reacting with normal and tanned sheep erythrocytes were the probable cause of false positive reactions given by 51 of 214 Liberian sera when using a commercial passive-haemagglutination test for hepatitis-B surface antigen. Absorption showed these agglutinins to be identical to those described earlier in Nigerian sera. Rheumatoid factor and anti-sheep-serum antibodies although present in 12 and five per cent respectively of all sera were not responsible for any false positive reactions. The practical conclusion is that such tests, based on sheep erythrocytes are unsuitable for screening this population.

  3. [Primary cervical cancer screening].

    PubMed

    Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María

    2015-01-01

    Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  4. Sensitivity and specificity of a two-question screening tool for depression in a specialist palliative care unit.

    PubMed

    Payne, Ann; Barry, Sandra; Creedon, Brian; Stone, Carol; Sweeney, Catherine; O' Brien, Tony; O' Sullivan, Kathleen

    2007-04-01

    The primary objective in this study is to determine the sensitivity and specificity of a two-item screening interview for depression versus the formal psychiatric interview, in the setting of a specialist palliative in-patient unit so that we may identify those individuals suffering from depressive disorder and therefore optimise their management in this often-complex population. A prospective sample of consecutive admissions (n = 167) consented to partake in the study, and the screening interview was asked separately to the formal psychiatric interview. The two-item questionnaire, achieved a sensitivity of 90.7% (95% CI 76.9-97.0) but a lower specificity of 67.7% (95% CI 58.7-75.7). The false positive rate was 32.3% (95% CI 24.3-41.3), but the false negative rate was found to be a low 9.3% (95% CI 3.0-23.1). A subgroup analysis of individuals with a past experience of depressive illness, (n = 95), revealed that a significant number screened positive for depression by the screening test, 55.2% (16/29) compared to those with no background history of depression, 33.3% (22/66) (P = 0.045). The high sensitivity and low false negative rate of the two-question screening tool will aid health professionals in identifying depression in the in-patient specialist palliative care unit. Individuals, who admit to a previous experience of depressive illness, are more likely to respond positively to the two-item questionnaire than those who report no prior history of depressive illness (P = 0.045).

  5. The Effects of Environmental Context on Recognition Memory and Claims of Remembering

    ERIC Educational Resources Information Center

    Hockley, William E.

    2008-01-01

    Recognition memory for words was tested in same or different contexts using the remember/know response procedure. Context was manipulated by presenting words in different screen colors and locations and by presenting words against real-world photographs. Overall hit and false-alarm rates were higher for tests presented in an old context compared…

  6. Screening for Ovarian Cancer: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Grossman, David C; Curry, Susan J; Owens, Douglas K; Barry, Michael J; Davidson, Karina W; Doubeni, Chyke A; Epling, John W; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Phipps, Maureen G; Silverstein, Michael; Simon, Melissa A; Tseng, Chien-Wen

    2018-02-13

    With approximately 14 000 deaths per year, ovarian cancer is the fifth most common cause of cancer death among US women and the leading cause of death from gynecologic cancer. More than 95% of ovarian cancer deaths occur among women 45 years and older. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on screening for ovarian cancer. The USPSTF reviewed the evidence on the benefits and harms of screening for ovarian cancer in asymptomatic women not known to be at high risk for ovarian cancer (ie, high risk includes women with certain hereditary cancer syndromes that increase their risk for ovarian cancer). Outcomes of interest included ovarian cancer mortality, quality of life, false-positive rate, surgery and surgical complication rates, and psychological effects of screening. The USPSTF found adequate evidence that screening for ovarian cancer does not reduce ovarian cancer mortality. The USPSTF found adequate evidence that the harms from screening for ovarian cancer are at least moderate and may be substantial in some cases, and include unnecessary surgery for women who do not have cancer. Given the lack of mortality benefit of screening, and the moderate to substantial harms that could result from false-positive screening test results and subsequent surgery, the USPSTF concludes with moderate certainty that the harms of screening for ovarian cancer outweigh the benefit, and the net balance of the benefit and harms of screening is negative. The USPSTF recommends against screening for ovarian cancer in asymptomatic women. (D recommendation) This recommendation applies to asymptomatic women who are not known to have a high-risk hereditary cancer syndrome.

  7. Cellular and Biophysical Pipeline for the Screening of Peroxisome Proliferator-Activated Receptor Beta/Delta Agonists: Avoiding False Positives

    PubMed Central

    Batista, Fernanda Aparecida Heleno

    2018-01-01

    Peroxisome proliferator-activated receptor beta/delta (PPARß/δ) is considered a therapeutic target for metabolic disorders, cancer, and cardiovascular diseases. Here, we developed one pipeline for the screening of PPARß/δ agonists, which reduces the cost, time, and false-positive hits. The first step is an optimized 3-day long cellular transactivation assay based on reporter-gene technology, which is supported by automated liquid-handlers. This primary screening is followed by a confirmatory transactivation assay and by two biophysical validation methods (thermal shift assay (TSA) and (ANS) fluorescence quenching), which allow the calculation of the affinity constant, giving more information about the selected hits. All of the assays were validated using well-known commercial agonists providing trustworthy data. Furthermore, to validate and test this pipeline, we screened a natural extract library (560 extracts), and we found one plant extract that might be interesting for PPARß/δ modulation. In conclusion, our results suggested that we developed a cheaper and more robust pipeline that goes beyond the single activation screening, as it also evaluates PPARß/δ tertiary structure stabilization and the ligand affinity constant, selecting only molecules that directly bind to the receptor. Moreover, this approach might improve the effectiveness of the screening for agonists that target PPARß/δ for drug development.

  8. Two-colored fluorescence correlation spectroscopy screening for LC3-P62 interaction inhibitors.

    PubMed

    Tsuganezawa, Keiko; Shinohara, Yoshiyasu; Ogawa, Naoko; Tsuboi, Shun; Okada, Norihisa; Mori, Masumi; Yokoyama, Shigeyuki; Noda, Nobuo N; Inagaki, Fuyuhiko; Ohsumi, Yoshinori; Tanaka, Akiko

    2013-10-01

    The fluorescence correlation spectroscopy (FCS)-based competitive binding assay to screen for protein-protein interaction inhibitors is a highly sensitive method as compared with the fluorescent polarization assay used conventionally. However, the FCS assay identifies many false-positive compounds, which requires specifically designed orthogonal screenings. A two-colored application of the FCS-based screening was newly developed, and inhibitors of a protein-protein interaction, involving selective autophagy, were selected. We focused on the interaction of LC3 with the adaptor protein p62, because the interaction is crucial to degrade the specific target proteins recruited by p62. First, about 10,000 compounds were subjected to the FCS-based competitive assay using a TAMRA-labeled p62-derived probe, and 29 hit compounds were selected. Next, the obtained hits were evaluated by the second FCS assay, using an Alexa647-labeled p62-derived probe to remove the false-positive compounds, and six hit compounds inhibited the interaction. Finally, we tested all 29 compounds by surface plasmon resonance-based competitive binding assay to evaluate their inhibition of the LC3-p62 interaction and selected two inhibitors with IC50 values less than 2 µM. The two-colored FCS-based screening was shown to be effective to screen for protein-protein interaction inhibitors.

  9. Improved diagnostics of chronic inflammatory prostatitis.

    PubMed

    Kulchavenya, E; Azizoff, A; Brizhatyuk, E; Khomyakov, V; Kholtobin, D; Breusoff, A; Naber, K G

    2012-12-01

    Prostatitis is a prevalent condition that encompasses a large array of clinical symptoms with significant impacts on men's life. The diagnosis and treatment of this disorder presents numerous challenges for urologists, most notably, a lack of specific and effective diagnostic methods. To improve the diagnostics the comparison of classic 4-glass test Meares and Stamey, 2-glass tests and 3-glass test was conducted in 177 men suspicious for chronic prostatitis. Four-glass test is uncomfortable both for patients and doctors, and leads to contamination of urine with prostatic secretion. Two-glass test is insufficiently effective too. Three-glass test (three urine specimens obtained from one continuous micturition stream) gives more adequate results and may be used for screening. Three-glass test as screening test with the option of an additional EPS investigation in those patients the final diagnosis of chronic prostatitis has to be confirmed is more convenient for patients and doctors than the standard M&S 4-glass test and "false-positive" (contaminated with EPS) midstream urine results are avoided thus improving discrimination of urethritis, cystitis and prostatitis. Therefore, we recommend the KE 3-glass test as a new standard for screening patients with signs and symptoms of chronic inflammatory prostatitis.

  10. Molecular markers for colorectal cancer screening

    PubMed Central

    Dickinson, Brandon T.; Kisiel, John; Ahlquist, David A.; Grady, William M.

    2016-01-01

    Colorectal cancer (CRC), although a significant cause of morbidity and mortality worldwide, has seen a declining incidence and mortality in countries with programmatic screening. Fecal occult blood testing (FOBT) and endoscopic approaches are the predominant screening methods currently. The discovery of the adenoma→carcinoma sequence and a greater understanding of the genetic and epigenetic changes that drive the formation of CRC have contributed to innovative research to identify molecular markers for highly accurate, non-invasive screening tests for CRC. DNA, proteins, messenger RNA, and micro-RNA have all been evaluated. The observation of tumor cell exfoliation into the mucocellular layer of the colonic epithelium and proven stability of DNA in a harsh stool environment make stool DNA a particularly promising marker. The development of a clinically useful stool DNA test has required numerous technical advances, including optimization in DNA stabilization, the development of assays with high analytical sensitivity, and the identification of specific and broadly informative molecular markers. A multi-target stool DNA (MT-sDNA) test, which combines both mutant and methylated DNA markers and a fecal immunochemical test (FIT), recently performed favorably in a large cross-sectional validation study and has been approved by the US Food and Drug Administration (FDA) for the screening of asymptomatic, average risk individuals. The ultimate way in which molecular marker screening assays will be used in clinical practice will require additional studies to determine optimal screening intervals, factors affecting compliance, management of false positive results, and the use of these assays in high-risk populations, as well as other considerations. PMID:25994221

  11. Comparison of Traditional and Reverse Syphilis Screening Algorithms in Medical Health Checkups.

    PubMed

    Nah, Eun Hee; Cho, Seon; Kim, Suyoung; Cho, Han Ik; Chai, Jong Yil

    2017-11-01

    The syphilis diagnostic algorithms applied in different countries vary significantly depending on the local syphilis epidemiology and other considerations, including the expected workload, the need for automation in the laboratory and budget factors. This study was performed to investigate the efficacy of traditional and reverse syphilis diagnostic algorithms during general health checkups. In total, 1,000 blood specimens were obtained from 908 men and 92 women during their regular health checkups. Traditional screening and reverse screening were applied to the same specimens using automatic rapid plasma regain (RPR) and Treponema pallidum latex agglutination (TPLA) tests, respectively. Specimens that were reverse algorithm (TPLA) reactive, were subjected to a second treponemal test performed by using the chemiluminescent microparticle immunoassay (CMIA). Of the 1,000 specimens tested, 68 (6.8%) were reactive by reverse screening (TPLA) compared with 11 (1.1%) by traditional screening (RPR). The traditional algorithm failed to detect 48 specimens [TPLA(+)/RPR(-)/CMIA(+)]. The median TPLA cutoff index (COI) was higher in CMIA-reactive cases than in CMIA-nonreactive cases (90.5 vs 12.5 U). The reverse screening algorithm could detect the subjects with possible latent syphilis who were not detected by the traditional algorithm. Those individuals could be provided with opportunities for evaluating syphilis during their health checkups. The COI values of the initial TPLA test may be helpful in excluding false-positive TPLA test results in the reverse algorithm. © The Korean Society for Laboratory Medicine

  12. Factors affecting faecal immunochemical test positive rates: demographic, pathological, behavioural and environmental variables.

    PubMed

    Symonds, Erin L; Osborne, Joanne M; Cole, Stephen R; Bampton, Peter A; Fraser, Robert J L; Young, Graeme P

    2015-12-01

    Positive rates in faecal immunochemical test (FIT)-based colorectal cancer screening programmes vary, suggesting that differences between programmes may affect test results. We examined whether demographic, pathological, behavioural, and environmental factors affected haemoglobin concentration and positive rates where samples are mailed. A retrospective cohort study; 34,298 collection devices were sent, over five years, to screening invitees (median age 60.6). Participant demographics, temperature on sample postage day, and previous screening were recorded. Outcomes from colonoscopy performed within a year following FIT were collected. Multivariate logistic regression identified significant predictors of test positivity. Higher positive rate was independently associated with male gender, older age, lower socioeconomic status, and distally located neoplasia, and negatively associated with previous screening (p < 0.05). Older males had higher faecal haemoglobin concentrations and were less likely to have a false positive result at colonoscopy (p < 0.05). High temperature on the sample postage day was associated with reduced haemoglobin concentration and positivity rate (26-35℃: Odds ratio 0.78, 95% confidence interval 0.66-0.93), but was not associated with missed significant neoplasia at colonoscopy (p > 0.05). Haemoglobin concentrations, and therefore FIT positivity, were affected by factors that vary between screening programmes. Participant demographics and high temperature at postage had significant effects. The impact of temperature could be reduced by seasonal scheduling of invitations. The importance of screening, and following up positive test results, particularly in older males, should be promoted. © The Author(s) 2015.

  13. Urine tests for Down's syndrome screening.

    PubMed

    Alldred, S Kate; Guo, Boliang; Takwoingi, Yemisi; Pennant, Mary; Wisniewski, Susanna; Deeks, Jonathan J; Neilson, James P; Alfirevic, Zarko

    2015-12-10

    Down's syndrome occurs when a person has three copies of chromosome 21, or the specific area of chromosome 21 implicated in causing Down's syndrome, rather than two. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life. The risk of a Down's syndrome affected pregnancy increases with advancing maternal age.Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. To estimate and compare the accuracy of first and second trimester urine markers for the detection of Down's syndrome. We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), EMBASE (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2011, Issue 7), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (archived 2007), Health Services Research Projects in Progress database (25 August 2011). We studied reference lists and published review articles. Studies evaluating tests of maternal urine in women up to 24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC (receiver operating characteristic) meta-analytical methods to analyse test performance and compare test accuracy. We performed analysis of studies allowing direct comparison between tests. We investigated the impact of maternal age on test performance in subgroup analyses. We included 19 studies involving 18,013 pregnancies (including 527 with Down's syndrome). Studies were generally of high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Twenty-four test combinations were evaluated formed from combinations of the following seven different markers with and without maternal age: AFP (alpha-fetoprotein), ITA (invasive trophoblast antigen), ß-core fragment, free ßhCG (beta human chorionic gonadotrophin), total hCG, oestriol, gonadotropin peptide and various marker ratios. The strategies evaluated included three double tests and seven single tests in combination with maternal age, and one triple test, two double tests and 11 single tests without maternal age. Twelve of the 19 studies only evaluated the performance of a single test strategy while the remaining seven evaluated at least two test strategies. Two marker combinations were evaluated in more than four studies; second trimester ß-core fragment (six studies), and second trimester ß-core fragment with maternal age (five studies).In direct test comparisons, for a 5% false positive rate (FPR), the diagnostic accuracy of the double marker second trimester ß-core fragment and oestriol with maternal age test combination was significantly better (ratio of diagnostic odds ratio (RDOR): 2.2 (95% confidence interval (CI) 1.1 to 4.5), P = 0.02) (summary sensitivity of 73% (CI 57 to 85) at a cut-point of 5% FPR) than that of the single marker test strategy of second trimester ß-core fragment and maternal age (summary sensitivity of 56% (CI 45 to 66) at a cut-point of 5% FPR), but was not significantly better (RDOR: 1.5 (0.8 to 2.8), P = 0.21) than that of the second trimester ß-core fragment to oestriol ratio and maternal age test strategy (summary sensitivity of 71% (CI 51 to 86) at a cut-point of 5% FPR). Tests involving second trimester ß-core fragment and oestriol with maternal age are significantly more sensitive than the single marker second trimester ß-core fragment and maternal age, however, there were few studies. There is a paucity of evidence available to support the use of urine testing for Down's syndrome screening in clinical practice where alternatives are available.

  14. Development of a qualitative indirect ELISA for the measurement of rabies virus-specific antibodies from vaccinated dogs and cats.

    PubMed

    Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R

    2004-04-01

    A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.

  15. Men's preferences and trade-offs for prostate cancer screening: a discrete choice experiment.

    PubMed

    Howard, Kirsten; Salkeld, Glenn P; Patel, Manish I; Mann, Graham J; Pignone, Michael P

    2015-12-01

    Prostate cancer screening using prostate-specific antigen (PSA) remains controversial. In deciding about screening, men must weigh the benefits and harms: little is known about benefit: harm trade-offs men are willing to accept. The objective of this study was to assess men's preferences for PSA screening, and the trade-offs between benefits and harms men are willing to accept when deciding about screening. Preferences of 662 men aged 40-69 were assessed using a discrete choice experiment. PSA screening was described by six attributes: prostate cancer deaths, prostate cancer diagnoses, unnecessary biopsies from false-positive PSA tests, impotence, urinary incontinence/bowel problems and cost. A mixed logit model was used to examine the influence of attributes on men's preferences for PSA testing; benefit: harm trade-offs were also calculated. Men's preferences were significantly influenced by test characteristics, particularly potential mortality benefit, unnecessary biopsies and likelihood of urinary incontinence or bowel problems; preferences were also influenced by age, prior PSA testing experience and perceived risk of prostate cancer. Men were willing to accept between 65 and 233 of 10 000 extra men with unnecessary biopsies, and between 31 and 72 of 10 000 extra men with incontinence/bowel problems to avoid one prostate cancer death. Differences in valuations of attributes and trade-offs acceptable to men of different ages suggest a one size fits all approach to PSA testing, regardless of age, may not reflect men's preferences. Our results can be used by policymakers to ensure screening programmes are in line with men's preferences and by clinicians and patients to facilitate informed discussions of the most relevant benefits and downsides of PSA screening for an individual man. © 2014 John Wiley & Sons Ltd.

  16. Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.

    PubMed

    Samuelson, Frank; Abbey, Craig

    2016-11-01

    Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.

  17. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    PubMed

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  18. A theoretical framework for measuring knowledge in screening decision aid trials.

    PubMed

    Smith, Sian K; Barratt, Alexandra; Trevena, Lyndal; Simpson, Judy M; Jansen, Jesse; McCaffery, Kirsten J

    2012-11-01

    To describe a theoretical framework for assessing knowledge about the possible outcomes of participating in bowel cancer screening for the faecal occult blood test. The content of the knowledge measure was based on the UK General Medical Council's screening guidelines and a theory-based approach to assessing gist knowledge (Fuzzy Trace Theory). It comprised conceptual and numeric questions to assess knowledge of the underlying construct (e.g. false positive concept) and the approximate numbers affected (e.g. likelihood of a false positive). The measure was used in a randomised controlled trial involving 530 adults with low education, to compare the impact of a bowel screening decision aid with a screening information booklet developed for the Australian Government National Bowel Cancer Screening Program. The numeric knowledge scale was particularly responsive to the effects of the decision aid; at follow-up decision aid participants' numeric knowledge was significantly greater than the controls (P<0.001). This contrasts with the conceptual knowledge scale which improved significantly in both groups from baseline to follow-up (P<0.001). Our theory-based knowledge measure was responsive to change in conceptual knowledge and to the effect on numeric knowledge of a decision aid. This theoretical framework has the potential to guide the development of knowledge measures in other screening settings. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Rapid bacteriological screening of cosmetic raw materials by using bioluminescence.

    PubMed

    Nielsen, P; Van Dellen, E

    1989-01-01

    Incoming cosmetic raw materials are routinely tested for microbial content. Standard plate count methods require up to 72 h. A rapid, sensitive, and inexpensive raw material screening method was developed that detects the presence of bacteria by means of ATP (bioluminescence). With a 24-h broth enrichment, the minimum bacterial ATP detection threshold of 1 cfu/g sample can be achieved using purified firefly luciferin-luciferase and an ATP releasing reagent. By using this rapid screen, microbiologically free material may be released for production within 24 h, while contaminated material undergoes further quantitative and identification testing. In order for a raw material to be validated for this method it must be evaluated for (1) a potential nonmicrobial light-contributing reaction resulting in a false positive or, (2) degradation of the ATP giving a false negative, and (3) confirmation that the raw material has not overwhelmed the buffering capacity of the enrichment broth. The key criteria for a rapid screen was the sensitivity to detect less than one colony forming unit per g product, the speed to do this within 24 h, and cost efficiency. Bioluminescence meets these criteria. With an enrichment step, it can detect less than one cfu/g sample. After the enrichment step, analysis time per sample is approximately 2 min and the cost for material and reagents is less than one dollar per sample.

  20. Predictive validity of curriculum-based measurement and teacher ratings of academic achievement.

    PubMed

    Kettler, Ryan J; Albers, Craig A

    2013-08-01

    Two alternative universal screening approaches to identify students with early learning difficulties were examined, along with a combination of these approaches. These approaches, consisting of (a) curriculum-based measurement (CBM) and (b) teacher ratings using Performance Screening Guides (PSGs), served as predictors of achievement tests in reading and mathematics. Participants included 413 students in grades 1, 2, and 3 in Tennessee (n=118) and Wisconsin (n=295) who were divided into six subsamples defined by grade and state. Reading and mathematics achievement tests with established psychometric properties were used as criteria within a concurrent and predictive validity framework. Across both achievement areas, CBM probes shared more variance with criterion measures than did teacher ratings, although teacher ratings added incremental validity among most subsamples. PSGs tended to be more accurate for identifying students in need of assistance at a 1-month interval, whereas CBM probes were more accurate at a 6-month interval. Teachers indicated that (a) false negatives are more problematic than are false positives, (b) both screening methods are useful for identifying early learning difficulties, and (c) both screening methods are useful for identifying students in need of interventions. Collectively, these findings suggest that the two types of measures, when used together, yield valuable information about students who need assistance in reading and mathematics. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  1. Incorporating thyroid markers in Down syndrome screening protocols.

    PubMed

    Dhaifalah, Ishraq; Salek, Tomas; Langova, Dagmar; Cuckle, Howard

    2017-05-01

    The article aimed to assess the benefit of incorporating maternal serum thyroid disease marker levels (thyroid-stimulating hormone and free thyroxine) into first trimester Down syndrome screening protocols. Statistical modelling was used to predict performance with and without the thyroid markers. Two protocols were considered: the combined test and the contingent cell-free DNA (cfDNA) test, where 15-40% women are selected for cfDNA because of increased risk based on combined test results. Published parameters were used for the combined test, cfDNA and the Down syndrome means for thyroid-stimulating hormone and free thyroxine; other parameters were derived from a series of 5230 women screened for both thyroid disease and Down syndrome. Combined test: For a fixed 85% detection rate, the predicted false positive rate was reduced from 5.3% to 3.6% with the addition of the thyroid markers. Contingent cfDNA test: For a fixed 95% detection rate, the proportion of women selected for cfDNA was reduced from 25.6% to 20.2%. When screening simultaneously for maternal thyroid disease and Down syndrome, thyroid marker levels should be used in the calculation of Down syndrome risk. The benefit is modest but can be achieved with no additional cost. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  2. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    PubMed

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  3. [Diagnostic work-up of pulmonary nodules : Management of pulmonary nodules detected with low‑dose CT screening].

    PubMed

    Wormanns, D

    2016-09-01

    Pulmonary nodules are the most frequent pathological finding in low-dose computed tomography (CT) scanning for early detection of lung cancer. Early stages of lung cancer are often manifested as pulmonary nodules; however, the very commonly occurring small nodules are predominantly benign. These benign nodules are responsible for the high percentage of false positive test results in screening studies. Appropriate diagnostic algorithms are necessary to reduce false positive screening results and to improve the specificity of lung cancer screening. Such algorithms are based on some of the basic principles comprehensively described in this article. Firstly, the diameter of nodules allows a differentiation between large (>8 mm) probably malignant and small (<8 mm) probably benign nodules. Secondly, some morphological features of pulmonary nodules in CT can prove their benign nature. Thirdly, growth of small nodules is the best non-invasive predictor of malignancy and is utilized as a trigger for further diagnostic work-up. Non-invasive testing using positron emission tomography (PET) and contrast enhancement as well as invasive diagnostic tests (e.g. various procedures for cytological and histological diagnostics) are briefly described in this article. Different nodule morphology using CT (e.g. solid and semisolid nodules) is associated with different biological behavior and different algorithms for follow-up are required. Currently, no obligatory algorithm is available in German-speaking countries for the management of pulmonary nodules, which reflects the current state of knowledge. The main features of some international and American recommendations are briefly presented in this article from which conclusions for the daily clinical use are derived.

  4. Using micropower impulse radar technology to screen for pneumothorax: an international bi-institutional study.

    PubMed

    van der Wilden, Gwendolyn M; Van der Wilden, Gwen; Albers, Christoph E; Albers, Christof; Haefeli, Pascal C; Haefeli, Peter; Zimmermann, Heinz; Zimmerman, Heinz; Exadaktylos, Aristomenis; Exadaktylos, Aris; Levy, Phillip; Birkhan, Oscar; Birkham, Oscar; Michaildou, Maria; Michailidou, Maria; Sideris, Antonios; Velmahos, George C; Velmahos, George; Alam, Hasan B; Alam, Hasan; King, David R; King, David; Fagenholz, Peter J; Fagenholz, Peter; Yeh, D Dante; Yeh, Dante; de Moya, Marc A

    2012-12-01

    Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. Diagnostic study, level III.

  5. Diagnostic performance of dual-staining cytology for cervical cancer screening: A systematic literature review.

    PubMed

    Tjalma, Wiebren A A

    2017-03-01

    Cervical cancer screening saves lives. Secondary prevention in cervical cancer screening relies on the results of primary cytology and/or HPV testing. However, primary screening with cytology has a low sensitivity, and HPV screening has a low specificity. This means that either cancers are missed, or women are over-treated. To improve performance outcomes, the concept of dual-stain cytology (CINtec ® PLUS Cytology test) has been introduced. In this approach, additional staining with p16/Ki-67 is performed in cases where cytology results are abnormal (LSIL or ASCUS) and/or HPV-positive. Another way to describe this approach might be "diagnostic" cytology. In order to assess the value of this "diagnostic cytology", a systematic literature review was conducted of dual-stain cytology performance across multiple studies until May 2016. In a Belgian screening population (women age 25-65 years), dual-stain cytology was significantly more sensitive (66%) and slightly less specific (-1.0%) than cytology. In the population referred to colposcopy or with abnormal cytology (ASCUS, LSIL), dual-staining showed a significantly higher increase in specificity, and a slightly lower sensitivity than HPV testing. Specificity gains resulted in fewer false positives and an increase in the number of correct referrals to colposcopy. Dual-staining with p16/Ki-67 cytology is an attractive biomarker approach for triage in cervical cancer screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. TORCH (toxoplasmosis, rubella, cytomegalovirus, and herpes simplex virus) screening of small for gestational age and intrauterine growth restricted neonates: efficacy study in a single institute in Korea.

    PubMed

    Chung, Mi Hae; Shin, Chan Ok; Lee, Juyoung

    2018-04-01

    Routine screening for toxoplasmosis, rubella, cytomegalovirus (CMV), and herpes simplex virus (TORCH) in intrauterine growth restriction (IUGR) and small for gestational age (SGA) neonates has become a common practice. However, the incidence of TORCH varies across countries, and the cost of TORCH testing may be disadvantageous compared to disease-specific screening. To evaluate the efficacy of TORCH screening, the medical charts of IUGR or SGA neonates born in a single institution in Bucheon, Korea from 2011 to 2015 were reviewed. The clinical data of the 126 IUGR or SGA neonates were gathered, including gestational age, Apgar scores, neonatal sonographic findings, chromosome study, morbidities, developmental follow-up, and growth catch-up. Maternal factors including underlying maternal disease and fetal sonography were collected, and placental findings were recorded when available. TORCH screening was done using serum IgM, CMV urine culture, quantification of CMV DNA with real-time polymerase chain reaction, and rapid plasma reagin qualitative test for syphilis. Tests were repeated only for those with positive results. Of the 119 TORCH screenings, only one was positive for toxoplasmosis IgM. This result was deemed false positive due to negative IgM on repeated testing and the absence of clinical symptoms. Considering the incidence and risk of TORCH in Korea, the financial burden of TORCH screening, and the single positive TORCH finding in our study, we suggest disease-specific screening based on maternal history and the clinical symptoms of the neonate. Regarding CMV, which may present asymptomatically, universal screening may be appropriate upon cost-benefit analysis.

  7. Magnetic Resonance Imaging as an Adjunct to Mammography for Breast Cancer Screening in Women at Less Than High Risk for Breast Cancer: A Health Technology Assessment

    PubMed Central

    Nikitovic-Jokic, Milica; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Among women at high risk for breast cancer, magnetic resonance imaging (MRI) has been suggested as a safe adjunct (supplemental) screening tool that can detect breast cancers missed on screening mammography, potentially reducing the number of deaths associated with the disease. However, the use of adjunct screening tests may also increase the number of false-positive test results, which may lead to unnecessary follow-up testing, as well as patient stress and anxiety. We investigated the benefits and harms of MRI as an adjunct to mammography compared with mammography alone for screening women at less than high risk (average or higher than average risk) for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects (DARE), Centre for Reviews and Dissemination (CRD) Health Technology Assessment Database, and National Health Service (NHS) Economic Evaluation Database, from January 2002 to January 2016, for evidence of effectiveness, harms, and diagnostic accuracy. Only studies evaluating the use of screening breast MRI as an adjunct to mammography in the specified populations were included. Results No studies in women at less than high risk for breast cancer met our inclusion criteria. Conclusions It remains uncertain if the use of adjunct screening breast MRI in women at less than high risk (average or higher than average risk) for breast cancer will reduce breast cancer–related mortality without significant increases in unnecessary follow-up testing and treatment. PMID:27990198

  8. TORCH (toxoplasmosis, rubella, cytomegalovirus, and herpes simplex virus) screening of small for gestational age and intrauterine growth restricted neonates: efficacy study in a single institute in Korea

    PubMed Central

    Chung, Mi Hae; Shin, Chan Ok

    2018-01-01

    Purpose Routine screening for toxoplasmosis, rubella, cytomegalovirus (CMV), and herpes simplex virus (TORCH) in intrauterine growth restriction (IUGR) and small for gestational age (SGA) neonates has become a common practice. However, the incidence of TORCH varies across countries, and the cost of TORCH testing may be disadvantageous compared to disease-specific screening. To evaluate the efficacy of TORCH screening, the medical charts of IUGR or SGA neonates born in a single institution in Bucheon, Korea from 2011 to 2015 were reviewed. Methods The clinical data of the 126 IUGR or SGA neonates were gathered, including gestational age, Apgar scores, neonatal sonographic findings, chromosome study, morbidities, developmental follow-up, and growth catch-up. Maternal factors including underlying maternal disease and fetal sonography were collected, and placental findings were recorded when available. TORCH screening was done using serum IgM, CMV urine culture, quantification of CMV DNA with real-time polymerase chain reaction, and rapid plasma reagin qualitative test for syphilis. Tests were repeated only for those with positive results. Results Of the 119 TORCH screenings, only one was positive for toxoplasmosis IgM. This result was deemed false positive due to negative IgM on repeated testing and the absence of clinical symptoms. Conclusion Considering the incidence and risk of TORCH in Korea, the financial burden of TORCH screening, and the single positive TORCH finding in our study, we suggest disease-specific screening based on maternal history and the clinical symptoms of the neonate. Regarding CMV, which may present asymptomatically, universal screening may be appropriate upon cost-benefit analysis. PMID:29713357

  9. Comparison of 1 mg and 2 mg overnight dexamethasone suppression tests for the screening of Cushing's syndrome in obese patients.

    PubMed

    Sahin, Mustafa; Kebapcilar, Levent; Taslipinar, Abdullah; Azal, Omer; Ozgurtas, Taner; Corakci, Ahmet; Akgul, Emin Ozgur; Taslipinar, Mine Yavuz; Yazici, Mahmut; Kutlu, Mustafa

    2009-01-01

    Obesity is currently a major public health problem and one of the potential underlying causes of obesity in a minority of patients is Cushing's syndrome (CS). Traditionally, the gold standard screening test for CS is 1 mg dexamethasone overnight suppression test. However, it is known that obese subjects have high false positive results with this test. We have therefore compared the 1 mg and 2 mg overnight dexamethasone suppression tests in obese subjects. Patients whose serum cortisol after ODST was >50 nM underwent and a low-dose dexamethasone suppression test (LDDST); 24-hour urine cortisol was collected for basal urinary free cortisol (UFC). For positive results after overnight 1-mg dexamethasone suppression test we also performed the overnight 2-mg dexamethasone suppression test. We prospectively evaluated 100 patients (22 men and 78 women, ranging in age from 17 to 73 years with a body mass index (BMI) >30 kg/m2 who had been referred to our hospital-affiliated endocrine clinic because of simple obesity. Suppression of serum cortisol to <50 nM (1.8 microg/dL) after dexamethasone administration was chosen as the cut-off point for normal suppression. Thyroid function tests, lipid profiles, homocysteine, antithyroglobulin, anti-thyroid peroxidase antibody levels, vitamin B12, folate levels, insulin resistance [by homeostasis model assessment (HOMA)] and 1.0 mg postdexamethasone (postdex) suppression cortisol levels were measured. We found an 8% false-positive rate in 1 mg overnight test and 2% in 2 mg overnight test (p=0.001). There was no correlation between the cortisol levels after ODST and other parameters. Our results indicate that the 2 mg overnight dexamethasone suppression test (ODST) is more convenient and accurate than 1-mg ODST as a screening test for excluding CS in subjects with simple obesity.

  10. Knowledge and future preference of Chinese women in a major public hospital in Hong Kong after undergoing non-invasive prenatal testing for positive aneuploidy screening: a questionnaire survey.

    PubMed

    Kou, Kam On; Poon, Chung Fan; Tse, Wai Ching; Mak, Shui Lam; Leung, Kwok Yin

    2015-09-02

    Despite the non-invasive nature of non-invasive prenatal testing (NIPT), there is still a need for a separate informed consent process before testing. The objectives of this study are to assess (a) knowledge and preferences of Chinese women in a major public hospital in Hong Kong who underwent NIPT, and (b) whether their knowledge and preferences differ depending on womens' characteristics and sources of information. Setting: Prenatal diagnosis and counselling clinic. Between February 2012 and September 2013, a questionnaire survey was distributed to all women who underwent NIPT after positive aneuploidy screening. As a pilot study, ten knowledge questions were designed based on the rapid response statement on Prenatal Detection of Down Syndrome using Massively Parallel Sequencing from the International Society for Prenatal Diagnosis in 2011. The source of women's knowledge and their preferences were also evaluated. While conventional screening was publicly funded, NIPT was not. Differences between subgroups were compared using chi square tests and logistic regression analysis. Of 152 women who underwent NIPT, 135 (88.8%) completed their questionnaires. More than 90% of women recognised the possibility of false positive and false negative results. Slightly more than 70% of women knew the inferior sensitivity of NIPT compared to an invasive test, and the possibility of an uninformative test result, but were not aware of the complicated aspects of NIPT. Pregnant women with an advanced level of education or those who underwent NIPT before 15 weeks provided answers that was more accurate by around 10-20% in two to three knowledge questions than those without. These associations were confirmed by multivariate logistic regression analysis. The women received information on NIPT largely from their private doctors (47.4%) and web (41.5%). In their future pregnancies, more women would opt for NIPT (a self-financed item) after positive screening ('free' in a public hospital) (57.8%) than as a primary screening (30.4%). It is feasible to use a questionnaire based on the ISPD statement on NIPT to assess women's knowledge of the test. The Chinese women who underwent NIPT recognised the limitations, but did not understand the complicated aspects. More information should be provided by health care professionals in order to facilitate an informed choice by patients. More women preferred NIPT as a contingent test than as a primary screening probably because of its high cost.

  11. Mass spectrometry in clinical chemistry: the case of newborn screening.

    PubMed

    la Marca, Giancarlo

    2014-12-01

    Newborn screening (NBS) program is a complex and organized system consisting of family and personnel education, biochemical tests, confirmatory biochemical and genetic tests, diagnosis, therapy, and patient follow up. The program identifies treatable metabolic disorders possibly when asymptomatic by using dried blood spot (DBS). During the last 20 years tandem mass spectrometry (TMS) has become the leading technology in NBS programs demonstrating to be versatile, sensitive and specific. There is consistent evidence of benefits from NBS for many disorders detected by TMS as well as for congenital hypothyroidism, cystic fibrosis, congenital adrenal hyperplasia by immune-enzymatic methods. Real time PCR tests have more recently been proposed for the detection of some severe combined immunodeficiences (SCID) along with the use of TMS for ADA and PNP SCID; a first evaluation of their cost-benefit ratio is still ongoing. Avoiding false negative results by using specific biomarkers and reducing the false positive rate by using second tier tests, is fundamental for a successful NBS program. The fully integration of NBS and diagnostic laboratories with clinical service is crucial to have the best effectiveness in a comprehensive NBS system. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. The value of the first trimester ultrasound in the era of cell free DNA screening.

    PubMed

    Rao, Rashmi R; Valderramos, Stephanie G; Silverman, Neil S; Han, Christina S; Platt, Lawrence D

    2016-12-01

    To describe the clinically relevant findings detected by the first trimester ultrasound (FTU) and to determine the additional value of the FTU compared to cell free DNA (cfDNA) alone. Retrospective cohort study of patients undergoing a FTU at a maternal-fetal medicine referral practice. Fetal, gynecologic, and placental findings detected by ultrasound were analyzed with available cfDNA and diagnostic testing results. A subgroup analysis of positive ultrasound findings and cfDNA results was performed to assess the additional benefit of ultrasound evaluation in FT prenatal screening. There were 1906 FTU between 1 October 2013 and 1 October 2014. CfDNA results were available for 959 (50%) patients. FTU detected: 42 fetal (2.2%), 286 gynecologic (15.0%), and 317 placental (16.6%) findings. CfDNA results were discordant with invasive testing results in 8/61 cases (13%) and with ultrasound findings in 18/42 (42%) cases. There were six false positive and two false negative cfDNA results confirmed by diagnostic testing. Subgroup analysis revealed that cfDNA as the sole method of prenatal screening in the FT would miss 95% of the fetal findings detected with ultrasound. The comprehensive FTU provides valuable clinical information about fetal and maternal anatomy that cannot be detected with cfDNA alone. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.

  13. Interval cancers in a population-based screening program for colorectal cancer in catalonia, Spain.

    PubMed

    Garcia, M; Domènech, X; Vidal, C; Torné, E; Milà, N; Binefa, G; Benito, L; Moreno, V

    2015-01-01

    Objective. To analyze interval cancers among participants in a screening program for colorectal cancer (CRC) during four screening rounds. Methods. The study population consisted of participants of a fecal occult blood test-based screening program from February 2000 to September 2010, with a 30-month follow-up (n = 30,480). We used hospital administration data to identify CRC. An interval cancer was defined as an invasive cancer diagnosed within 30 months of a negative screening result and before the next recommended examination. Gender, age, stage, and site distribution of interval cancers were compared with those in the screen-detected group. Results. Within the study period, 97 tumors were screen-detected and 74 tumors were diagnosed after a negative screening. In addition, 17 CRC (18.3%) were found after an inconclusive result and 2 cases were diagnosed within the surveillance interval (2.1%). There was an increase of interval cancers over the four rounds (from 32.4% to 46.0%). When compared with screen-detected cancers, interval cancers were found predominantly in the rectum (OR: 3.66; 95% CI: 1.51-8.88) and at more advanced stages (P = 0.025). Conclusion. There are large numbers of cancer that are not detected through fecal occult blood test-based screening. The low sensitivity should be emphasized to ensure that individuals with symptoms are not falsely reassured.

  14. The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.

    PubMed

    Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M

    2016-09-01

    One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  15. Antenatal screening for Down syndrome using serum placental growth factor with the combined, quadruple, serum integrated and integrated tests.

    PubMed

    Wald, Nicholas J; Bestwick, Jonathan P; George, Lynne M; Huttly, Wayne J

    2012-01-01

    To estimate the value of first or second trimester placental growth factor (PlGF) as an additional antenatal screening marker for Down syndrome. Nested case-control study. Antenatal screening service. 532 Down syndrome pregnancies and 1,155 matched unaffected pregnancies. Stored maternal serum samples (-40°C) were assayed for PlGF. Monte Carlo simulation was used to estimate the screening performance of PlGF with the Combined, Quadruple, serum Integrated and Integrated tests. Median PlGF levels in affected and unaffected pregnancies and screening performance (detection rates [DR] for specified false-positive rates [FPR] and vice versa). First trimester median PlGF was 15%, 28% and 39% lower in Down syndrome than unaffected pregnancies at 11, 12 and 13 completed weeks' gestation respectively (all p<0.001). Second trimester median PlGF was 31% lower at 14 weeks (p<0.001), and the difference decreased (6% lower at 17 weeks). At a 90% DR with first trimester markers measured at 13 weeks, adding PlGF decreased the FPR from 11.1 to 5.1% using the Combined test, 9.3% to 4.5% using the serum Integrated test, and 3.4% to 1.5% using the Integrated test (or 1.5 to 1.4% with first trimester markers measured at 11 weeks). Adding PlGF to the Quadruple test (measured at 15 weeks) decreased the FPR from 10.0% to 9.6% at a 90% DR. First trimester PlGF measurements improve the performance of antenatal screening for Down syndrome using the Combined, serum Integrated and Integrated tests. Second trimester PlGF measurements are of limited value.

  16. Unethical randomised controlled trial of cervical screening in India: US Freedom of Information Act disclosures.

    PubMed

    Suba, Eric J; Ortega, Robert E; Mutch, David G

    2017-01-01

    A randomised controlled trial conducted in Mumbai, India, compared invasive cervical cancer rates among women offered cervical screening with invasive cervical cancer rates among women offered no-screening. The US Office for Human Research Protections determined the Mumbai trial was unethical because informed consent was not obtained from trial participants. Reportedly, cervical screening in the Mumbai trial reduced invasive cervical cancer mortality rates, but not invasive cervical cancer incidence rates. Documents obtained through the US Freedom of Information Act disclose that the US National Cancer Institute funded the Mumbai trial from 1997 to 2015 to study 'visual inspection/downstaging' tests. However, 'visual inspection/downstaging' tests had been judged unsatisfactory for cancer control before the Mumbai trial began. 'Visual inspection/downstaging' tests failed to reduce invasive cervical cancer incidence rates in Mumbai because 'visual inspection/downstaging' tests, by design, failed to detect preinvasive cervical lesions. None of the 151 538 Mumbai trial participants, in either the intervention or control arms, received cervical screening tests that detected preinvasive cervical lesions. Because of missing/discrepant clinical staging data, it is uncertain whether 'visual inspection/downstaging' tests actually reduced invasive cervical cancer mortality rates in Mumbai. Documents obtained through the US Freedom of Information Act disclose that US National Cancer Institute leaders avoided accountability by making false and misleading statements to Congressional oversight staff. Our findings contradict assurances given to President Barack Obama that regulations pertaining to global health research supported by the US government adequately protect human participants from unethical treatment. US National Cancer Institute leaders should develop policies to compensate victims of unethical global health research. All surviving Mumbai trial participants should finally receive cervical screening tests that detect preinvasive cervical lesions.

  17. Comparison of 4th-Generation HIV Antigen/Antibody Combination Assay With 3rd-Generation HIV Antibody Assays for the Occurrence of False-Positive and False-Negative Results.

    PubMed

    Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim

    2015-01-01

    To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).

  18. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening.

    PubMed

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-11-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access.

  19. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening

    PubMed Central

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-01-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access. PMID:25782669

  20. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Outcomes of transient evoked otoacoustic emission testing in 6-year-old school children: a comparison with pure tone screening and tympanometry.

    PubMed

    Driscoll, C; Kei, J; McPherson, B

    2001-01-01

    (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at > or =1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery.

  2. Screening for the presence of lipophilic marine biotoxins in shellfish samples using the neuro-2a bioassay.

    PubMed

    Bodero, Marcia; Bovee, Toine F H; Wang, Si; Hoogenboom, Ron L A P; Klijnstra, Mirjam D; Portier, Liza; Hendriksen, Peter J M; Gerssen, Arjen

    2018-02-01

    The neuro-2a bioassay is considered as one of the most promising cell-based in vitro bioassays for the broad screening of seafood products for the presence of marine biotoxins. The neuro-2a assay has been shown to detect a wide array of toxins like paralytic shellfish poisons (PSPs), ciguatoxins, and also lipophilic marine biotoxins (LMBs). However, the neuro-2a assay is rarely used for routine testing of samples due to matrix effects that, for example, lead to false positives when testing for LMBs. As a result there are only limited data on validation and evaluation of its performance on real samples. In the present study, the standard extraction procedure for LMBs was adjusted by introducing an additional clean-up step with n-hexane. Recovery losses due to this extra step were less than 10%. This wash step was a crucial addition in order to eliminate false-positive outcomes due to matrix effects. Next, the applicability of this assay was assessed by testing a broad range of shellfish samples contaminated with various LMBs, including diarrhetic shellfish toxins/poisons (DSPs). For comparison, the samples were also analysed by LC-MS/MS. Standards of all regulated LMBs were tested, including analogues of some of these toxins. The neuro-2a cells showed good sensitivity towards all compounds. Extracts of 87 samples, both blank and contaminated with various toxins, were tested. The neuro-2a outcomes were in line with those of LC-MS/MS analysis and support the applicability of this assay for the screening of samples for LMBs. However, for use in a daily routine setting, the test might be further improved and we discuss several recommended modifications which should be considered before a full validation is carried out.

  3. Validation of the Explorer® 2.0 test coupled to e-Reader® for the screening of antimicrobials in muscle from different animal species.

    PubMed

    Mata, Luis; Sanz, David; Razquin, Pedro

    2014-01-01

    The Explorer(®) 2.0 tube test is a microbial inhibition test for the screening of antimicrobial residues in food samples. The new e-Reader(®) device coupled to Explorer(®) 2.0 operates by incubation at a selected temperature, determination of the endpoint of the assay and interpretation to generate results. This system was validated for muscle samples according to the European Commission Decision 2002/657/EC. Sensitivity towards 25 substances from several groups of antimicrobials was investigated in a first step. Detection capabilities for six substances representing the six major antimicrobial groups were also determined in bovine muscle. The detection capabilities for amoxicillin (10 µg l(-1)), cefalexin (200 µg l(-1)), doxycyclin (100 µg l(-1)), sulfamethazine (100 µg l(-1)), tylosin (100 µg l(-1)) and neomycin (200 µg l(-1)) were in all cases at or below the maximum residue limit (MRL). Specificity and applicability of the test were demonstrated with muscle samples from four animal species (bovine, porcine, ovine and poultry) and results were found to be satisfactory. Ruggedness was evaluated on negative and spiked samples with sulfamethazine as a representative antimicrobial. Neither false-positives nor false-negatives were detected when varying the sample volume, the time of pre-incubation, the temperature of incubation and the batch of the test. These results prove that Explorer(®) 2.0 coupled to e-Reader(®) is a valuable tool for the screening of a broad range of antimicrobials in muscle. This new methodology simplifies the analysis and increases the accuracy of interpretation of the test results since the endpoint of the assay is automatically determined and results are interpreted objectively.

  4. US women's attitudes to false positive mammography results and detection of ductal carcinoma in situ: cross sectional survey

    PubMed Central

    Schwartz, Lisa M; Woloshin, Steven; Sox, Harold C; Fischhoff, Baruch; Welch, H Gilbert

    2000-01-01

    Objective To determine women's attitudes to and knowledge of both false positive mammography results and the detection of ductal carcinoma in situ after screening mammography. Design Cross sectional survey. Setting United States. Participants 479 women aged 18-97 years who did not report a history of breast cancer. Main outcome measures Attitudes to and knowledge of false positive results and the detection of ductal carcinoma in situ after screening mammography. Results Women were aware that false positive results do occur. Their median estimate of the false positive rate for 10 years of annual screening was 20% (25th percentile estimate, 10%; 75th percentile estimate, 45%). The women were highly tolerant of false positives: 63% thought that 500 or more false positives per life saved was reasonable and 37% would tolerate 10 000 or more. Women who had had a false positive result (n=76) expressed the same high tolerance: 39% would tolerate 10 000 or more false positives. 62% of women did not want to take false positive results into account when deciding about screening. Only 8% of women thought that mammography could harm a woman without breast cancer, and 94% doubted the possibility of non-progressive breast cancers. Few had heard about ductal carcinoma in situ, a cancer that may not progress, but when informed, 60% of women wanted to take into account the possibility of it being detected when deciding about screening. Conclusions Women are aware of false positives and seem to view them as an acceptable consequence of screening mammography. In contrast, most women are unaware that screening can detect cancers that may never progress but feel that such information would be relevant. Education should perhaps focus less on false positives and more on the less familiar outcome of detection of ductal carcinoma in situ. PMID:10856064

  5. Exploring the acceptability of human papillomavirus self-sampling among Muslim immigrant women.

    PubMed

    Lofters, Aisha K; Vahabi, Mandana; Fardad, Mitra; Raza, Afrah

    2017-01-01

    With appropriate screening (ie, the Papanicolaou [Pap] test), cervical cancer is highly preventable, and high-income countries, including Canada, have observed significant decreases in cervical cancer mortality. However, certain subgroups, including immigrants from countries with large Muslim populations, experience disparities in cervical cancer screening. Little is known about the acceptability of human papillomavirus (HPV) self-sampling as a screening strategy among Muslim immigrant women in Canada. This study assessed cervical cancer screening practices, knowledge and attitudes, and acceptability of HPV self-sampling among Muslim immigrant women. A convenience sample of 30 women was recruited over a 3-month period (June-August 2015) in the Greater Toronto Area. All women were between 21 and 69 years old, foreign-born, and self-identified as Muslim, and had good knowledge of English. Data were collected through a self-completed questionnaire. More than half of the participants falsely indicated that Pap tests may cause cervical infection, and 46.7% indicated that the test is an intrusion on privacy. The majority of women reported that they would be willing to try HPV self-sampling, and more than half would prefer this method to provider-administered sampling methods. Barriers to self-sampling included confidence in the ability to perform the test and perceived cost, and facilitators included convenience and privacy being preserved. The results demonstrate that HPV self-sampling may provide a favorable alternative model of care to the traditional provider-administered Pap testing. These findings add important information to the literature related to promoting cancer screening among women who are under or never screened for cervical cancer.

  6. Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.

    PubMed

    Chapey, Emmanuelle; Wallon, Martine; Peyron, François

    2017-01-01

    The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. A case of placental trisomy 18 mosaicism causing a false negative NIPT result.

    PubMed

    Yang, Jiexia; Qi, Yiming; Guo, Fangfang; Hou, Yaping; Peng, Haishan; Wang, Dongmei; Oy, Haoxin; Yin, Aihua

    2017-01-01

    The non-invasive prenatal testing that evaluates circulating cell free DNA, and has been established as an additional pregnancy test for detecting the common fetal trisomies 21, 18 and 13 is rapidly revolutionizing prenatal screening as a result of its increased sensitivity and specificity. However, false positive and false negative results still exist. We presented a case in which the non-invasive prenatal testing results were normal at 15 gestational age (GA), but an ultrasound examination at 30GA showed that the fetus had heart abnormalities, and the third trimester ultrasound at 33GA noted multiple anomalies including a 3.0 mm ventricular septal defect. Along with cordocentesis at 33GA, the cord blood sample cytogenetics analysis showed a mos 47,XN,+18[61]/46,XN[39] T18 karyotype. Six placental biopsies confirmed that the chromosome 18 placenta chimerism ratio had changed from 33% to 72%. Ultimately, the pregnancy was interrupted at 34GA. We presented this case to highlight the need to clearly explain false positive or false negative results to patients. We believe that this information will also influence the development of future diagnostic test methodologies.

  8. Should all women with cervical atypia be referred for colposcopy: a HARNET study. Harrisburgh Area Research Network.

    PubMed

    Slawson, D C; Bennett, J H; Simon, L J; Herman, J M

    1994-04-01

    Clinicians who manage women with Papanicolaou (Pap) smears showing atypical squamous cells of undetermined significance (ASCUS) may miss clinically significant cervical disease by repeating the cytology alone. We evaluated the ability of the human papillomavirus (HPV) screen and the naked-eye examination after a cervical acetic acid wash to enhance the follow-up Pap smear in predicting an abnormal colposcopic biopsy. Pap smears were performed on all women (N = 7458) attending six family practice offices for a health maintenance examination from August 1989 through February 1991. Consenting subjects with ASCUS underwent repeat cytological testing, an HPV screen, and a cervical acetic acid wash examination immediately before colposcopy after a 4- to 6-month waiting period. Of the 122 consenting women identified with ASCUS, 67 (55%) demonstrated abnormalities on biopsy, including 26 with condyloma, 26 with cervical intraepithelial neoplasia I (CIN I), and 15 with CIN II to III. The false-negative rate, 58%, of the follow-up Pap smear alone for detecting these cases of condyloma and CIN was significantly decreased (false-negative rate, 27%) with the use of the cervical acetic acid wash as an adjunctive test. There was no additional reduction in the false-negative rate with the use of the HPV screen. Of the 15 subjects with high-grade cervical lesions (CIN II to III), 14 had either an abnormal follow-up Pap smear or an abnormal cervical acetic acid wash examination. Among women with cervical atypia, a single follow-up Pap smear alone failed to detect one third of the cases of high-grade disease. Ninety-three percent of these cases were detected, however, with a follow-up Pap smear and an acetic acid wash. Our one subject with a high-grade lesion missed with this combination of tests had an unsatisfactory Pap smear. Use of both tests together may reliably guide clinical decisions regarding the management of cervical atypia.

  9. The use of the Micral-Test strip to identify the presence of microalbuminuria in people with insulin dependent diabetes mellitus (IDDM) participating in the EUCLID study.

    PubMed

    Webb, D J; Newman, D J; Chaturvedi, N; Fuller, J H

    1996-03-01

    In IDDM, microalbuminuria (urinary albumin excretion rate (AER) of 20-200 micrograms/min) is a predictor of persistent proteinuria and diabetic nephropathy. Early intervention may prevent or reduce the rate of progression of renal complications. The Micral-Test strip can be used to establish a semi-quantitative estimate of AER. We assessed the field performance of the Micral-Test strip in detecting microalbuminuria in the EUCLID study, an European wide, 18 centre study of 530 IDDM participants, aged 20 to 59 years. People with macroalbuminuria were excluded. On entry, all participants had albumin concentrations from two overnight urine collections measured by a central laboratory, and the corresponding Micral-Test performed on the two collections locally. a cut off of > or = mg/l albumin from the first Micral-Test, to detect a centrally measured albumin concentration > or = 20 mg/l, yielded 29 (5.8%) false negative results and 58 (11.6%) false positive results (sensitivity 70%, specificity 87%). The mean AER, from two collections, was compared with the corresponding 'pooled' Micral-Test results (mean of the two readings). Receiver Operating Characteristic (ROC) curves were used to assess if there was a suitable 'pooled' Micral-Test result for screening microalbuminuria. A 'pooled' Micral-Test result (> or = 15 mg/l) was used to detect mean AER > or = 20 micrograms/min (sensitivity 78%, specificity 77%). This 'pooled cut-off' had already been used for screening on to the study and led to an over-estimate (154 vs. 77) of the true number of microalbuminuric participants on the study. In conclusion, our findings suggest that the Micral-Test strip is not an effective screening tool for microalbuminuria, using the 'pooled' result from two measurements did not improve the sensitivity of the test.

  10. Effect of a new marker, ADAM12, on Down risk figures in first trimester screening.

    PubMed

    Valinen, Yrtti; Laitinen, Paivi; Ranta, Jenni; Ignatius, Jaakko; Jarvela, Ilkka; Ryynänen, Markku

    2009-07-01

    To investigate whether incorporating the measurement of ADAM12 in the risk calculation program LifeCycle, can improve Down screening in the first trimester. In a retrospective case control study, maternal serum ADAM12 concentrations were measured and compared in Down syndrome cases (n = 53) and in controls (n = 226) obtained from first trimester (9-12 weeks) screening samples in Oulu and Kuopio University Hospitals. Median concentration ( microg/l), observed and regressed (weight corrected) MoMs of ADAM12 were calculated. There was a significant difference in ADAM12 levels between Downs and controls during the pregnancy weeks 9 + 0 to 10 + 6, but not thereafter. By adding ADAM12 to the marker set used in the risk calculation program, one screening false negative Down syndrome case occurred in the affected population, which did not alter false positive rate. Adding ADAM12 as a parameter in Down screening did not cause radical changes in the risk value. The test might be useful at 9 and 10 weeks in which it might have the potential to improve the performance of the risk assessment especially for women receiving a result close to the high-risk cut-off. The real influence of ADAM12 remains to be elucidated in larger studies incorporating ADAM12 to the risk calculation program.

  11. Phaeochromocytoma: diagnostic challenges for biochemical screening and diagnosis.

    PubMed

    Barron, Jeffrey

    2010-08-01

    The aim of this article is to provide knowledge of the origin of catecholamines and metabolites so that there can be an informed approach to the methods for biochemical screening for a possible phaeochromocytoma; The article includes a review of catecholamine and metadrenaline metabolism, with methods used in biochemical screening. In the adrenal medulla and a phaeochromocytoma, catecholamines continuously leak from chromaffin granules into the cytoplasm and are converted to metadrenalines. For a phaeochromocytoma to become biochemically detectable, metnoradrenaline secretion needs to rise fourfold, whereas noradrenaline secretion needs to rise 15-fold. The prevalence of a sporadic phaeochromocytoma is low; therefore false-positive results exceed true-positive results. Assay sensitivity is high because it is important not to miss a possible phaeochromocytoma. The use of urine or plasma fractionated metadrenalines as the first-line test has been recommended due to improved sensitivity. A negative result excludes a phaeochromocytoma. Only after a sporadic phaeochromocytoma has been diagnosed biochemically is it cost effective to request imaging. Sensitivities and specificities of the assays differ according to pre-test probabilities of the presence of a phaeochromocytoma, with hereditary and incidentalomas having a higher pre-test probability than sporadic phaeochromocytoma. In conclusion, in screening for a possible phaeochromocytoma, biochemical investigations should be completed first to exclude or establish the diagnosis. The preferred biochemical screening test is fractionated metadrenalines, including methoxytyramine so as not to miss dopamine-secreting tumours.

  12. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  13. Challenges associated with post-deployment screening for mild traumatic brain injury in military personnel.

    PubMed

    Iverson, Grant L; Langlois, Jean A; McCrea, Michael A; Kelly, James P

    2009-11-01

    There is ongoing debate regarding the epidemiology of mild traumatic brain injury (MTBI) in military personnel. Accurate and timely estimates of the incidence of brain injury and the prevalence of long-term problems associated with brain injuries among active duty service members and veterans are essential for (a) operational planning, and (b) to allocate sufficient resources for rehabilitation and ongoing services and supports. The purpose of this article is to discuss challenges associated with post-deployment screening for MTBI. Multiple screening methods have been used in military, Veterans Affairs, and independent studies, which complicate cross-study comparisons of the resulting epidemiological data. We believe that post-deployment screening is important and necessary--but no screening methodology will be flawless, and false positives and false negatives are inevitable. Additional research is necessary to refine the sequential screening methodology, with the goal of minimizing false negatives during initial post-deployment screening and minimizing false positives during follow-up evaluations.

  14. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    PubMed

    van Turenhout, Sietze T; Oort, Frank A; Terhaar sive Droste, Jochim S; Coupé, Veerle M H; van der Hulst, Rene W; Loffeld, Ruud J; Scholten, Pieter; Depla, Annekatrien C T M; Bouman, Anneke A; Meijer, Gerrit A; Mulder, Chris J J; van Rossum, Leo G M

    2012-07-01

    Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. To determine the contribution of hemorrhoids to the frequency of FP FIT results. Retrospective analysis from prospective cohort study. Five large teaching hospitals, including 1 academic hospital. All subjects scheduled for elective colonoscopy. FIT before bowel preparation. Frequency of FP FIT results in subjects with hemorrhoids as the only relevant abnormality compared with FP FIT results in subjects with no relevant abnormalities. Logistic regression analysis to determine colonic abnormalities influencing FP results. In 2855 patients, 434 had positive FIT results: 213 had advanced neoplasia and 221 had FP results. In 9 individuals (4.1%; 95% CI, 1.4-6.8) with an FP FIT result, hemorrhoids were the only abnormality. In univariate unadjusted analysis, subjects with hemorrhoids as the only abnormality did not have more positive results (9/134; 6.7%) compared with subjects without any abnormalities (43/886; 4.9%; P = .396). Logistic regression identified hemorrhoids, nonadvanced polyps, and a group of miscellaneous abnormalities, all significantly influencing false positivity. Of 1000 subjects with hemorrhoids, 67 would have FP results, of whom 18 would have FP results because of hemorrhoids only. Potential underreporting of hemorrhoids; high-risk individuals. Hemorrhoids in individuals participating in colorectal cancer screening will probably not lead to a substantial number of false-positive test results. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  15. [Interval cancers and episode sensitivity in population-based screening programmes for colorectal cancer: a systematic review].

    PubMed

    Domènech, Xènia; Garcia, Montse; Benito, Llúcia; Binefa, Gemma; Vidal, Carmen; Milà, Núria; Moreno, Víctor

    2015-01-01

    To describe interval cancers (IC) and the sensitivity of colorectal cancer (CRC) screening programmes. A systematic review of the literature was conducted through a MEDLINE (PubMed) search. The search strategy combined the terms 'interval cancer', 'false negative', 'mass screening', 'screening' 'early detection of cancer', 'colorectal cancer' and 'bowel cancer'. Inclusion criteria consisted of population-based screening programmes, original articles written in English or Spanish and publication dates between 1999/01/01 and 2015/02/28. A narrative synthesis of the included articles was performed detailing the characteristics of the screening programmes, the IC rate, and the information sources used in each study. Thirteen articles were included. The episode sensitivity of CRC screening programmes ranged from 42.2% to 65.3% in programmes using the guaiac test and between 59.1% and 87.0% with the immunochemical test. We found a higher proportion of women who were diagnosed with IC and these lesions were mainly located in the proximal colon. There is wide variability in the IC rate in CRC programmes. To ensure comparability between programmes, there is a need for consensus on the working definition of IC and the methods used for their identification and quantification. Copyright © 2014 SESPAS. Published by Elsevier Espana. All rights reserved.

  16. What is overdiagnosis and why should we take it seriously in cancer screening?

    PubMed

    Carter, Stacy M; Barratt, Alexandra

    2017-07-26

    Overdiagnosis occurs in a population when conditions are diagnosed correctly but the diagnosis produces an unfavourable balance between benefits and harms. In cancer screening, overdiagnosed cancers are those that did not need to be found because they would not have produced symptoms or led to premature death. These overdiagnosed cancers can be distinguished from false positives, which occur when an initial screening test suggests that a person is at high risk but follow-up testing shows them to be at normal risk. The cancers most likely to be overdiagnosed through screening are those of the prostate, thyroid, breast and lung. Overdiagnosis in cancer screening arises largely from the paradoxical problem that screening is most likely to find the slow-growing or dormant cancers that are least likely to harm us, and less likely to find the aggressive, fast-growing cancers that cause cancer mortality. This central paradox has become clearer over recent decades. The more overdiagnosis is produced by a screening program, the less likely the program is to serve its ultimate goal of reducing illness and premature death from cancer. Thus, it is vital that health professionals and researchers continue an open, scientific inquiry into the extent and consequences of overdiagnosis, and devise appropriate responses to it.

  17. Automation of a flocculation test for syphilis on Groupamatic equipment.

    PubMed Central

    Garretta, M; Paris-Hamelin, A; Gener, J; Muller, A; Matte, C; Vaisman, A

    1975-01-01

    A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned. Images PMID:1098731

  18. A solid-phase assay for the detection of anti-sperm antibodies.

    PubMed

    Okada, H; Kamidono, S; Owens, G R; Nagamatsu, G R; Addonizio, J C

    1993-05-01

    ELISA is an ideal assay method for a large-scale screening of anti-sperm antibodies among a large number of infertile males. However, conventional ELISA with whole spermatozoa needs time-consuming steps of centrifugation. A solid-phase assay used for detecting anti-sperm antibodies was established. This assay is suitable not only for detecting circulating anti-sperm antibodies of IgG, IgM, and IgA subclass simultaneously but also for screening hybridomas secreting anti-sperm monoclonal antibodies (mAbs). The microtiter plates, on which solubilized sperm antigens are fixed, can be stored at -80 degrees C for up to six months without losing reactivity with anti-sperm antibodies. Using this assay, 53 sera (13 were proven positive and 40 were proven negative for sperm agglutination antibody) were tested. Although the false-negative rate was 0%, the false-positive rate was 32%. One thousand one hundred sixty-five supernatants from hybridomas constructed with splenocytes of mice who were hyperimmunized with human sperm and nonsecreting myeloma cells were tested by this solid-phase assay and two anti-sperm mAb secreting clones were selected and established. It is recommended that for research work this assay could be used for the first screening of the hybridoma secreting anti-sperm mAb, and for clinical use this assay might be suitable for the first screening of sera of infertile patients. However, conventional bioassays should follow to confirm the biological meaning of the positivity.

  19. A preliminary investigation into the use of biosensors to screen stomach contents for selected poisons and drugs.

    PubMed

    Redshaw, Natalie; Dickson, Stuart J; Ambrose, Vikki; Horswell, Jacqui

    2007-10-25

    The bioluminescence response of two genetically modified (lux-marked) bacteria to potentially toxic compounds (PTCs) in stomach contents was monitored using an in vitro assay. Cells of Escherichia coli HB101 and Salmonella typhimurium both carrying the lux light producing gene on a plasmid (pUDC607) were added to stomach contents containing various concentrations of organic and inorganic compounds. There was some variability in the response of the two biosensors, but both were sensitive to the herbicides glyphosate, 2,4-dichlorophenoxyacetic acid (2,4-D), 2,4,5-trichlorophenoxyacetic acid (2,4,5-T); pentachlorophenol (PCP), and inorganic poisons arsenic and mercury at a concentration range likely to be found in stomach contents samples submitted for toxicological analysis. This study demonstrates that biosensor bioassays could be a useful preliminary screening tool in forensic toxicology and that such a toxicological screening should include more than one test organism to maximise the number of PTC's detected. The probability of false positive results from samples containing compounds that may interfere with the assay such as over-the-counter (OTC) drugs and caffeine in tea and coffee was also investigated. Of the substances tested only coffee has the potential to cause false positive results.

  20. Infectious agent screening in canine blood donors in the United Kingdom.

    PubMed

    Crawford, K; Walton, J; Lewis, D; Tasker, S; Warman, S M

    2013-08-01

    Transfusion of blood products is an important component of veterinary emergency medicine. Donors must be carefully selected to minimise risk of transmission of blood-borne infectious agents. This study was devised to assess the prevalence of such agents in healthy, non-travelled UK dogs screened as prospective donors. Ethylenediaminetetraacetic acid blood samples from dogs donating blood between August 2007 and January 2012 were screened by polymerase chain reaction for haemotropic mycoplasmas, Bartonella, Babesia, Leishmania, Ehrlichia and Anaplasma spp. Dogs with positive or inconclusive results underwent repeat polymerase chain reaction testing. Four of 262 dogs had positive or inconclusive results at initial screening. Repeat polymerase chain reaction testing in each dog was negative, and none of the dogs developed clinical signs of disease. The positive results on initial screening may have represented false positives from sample contamination or amplification of non-target DNA. It is also possible that dogs were infected at initial sampling but successfully cleared infection before repeat testing. The low number of positive results obtained suggests that prevalence of these agents in a population of healthy UK dogs is low and that use of blood products is unlikely to represent a significant risk of transmission of these diseases. © 2013 British Small Animal Veterinary Association.

  1. High hepatitis B seroprevalence and risk factors for infection in pregnant women on the Thailand-Myanmar Border.

    PubMed

    Banks, Tristan; Kang, Joy; Watts, Isabella; Tyrosvoutis, Mary Ellen G; Min, Aung Myat; Tun, Nay Win; Keereecharoen, Lily; Simmawong, Wiriya; Wanyatip, Sunaree; Hanboonkunupakarn, Borimas; Nosten, François; McGready, Rose

    2016-04-28

    Infection from Hepatitis B primarily results from peri-partum vertical transmission and the risk increases in the presence of hepatitis B e antigen. We aimed to evaluate a new screening program for hepatitis B in pregnant women as a component of antenatal services in a marginalized population. Counseling and screening for hepatitis B screening was offered to all women at the first visit, at Shoklo Malaria Research Unit (SMRU) antenatal clinics on the Thai-Myanmar border.  Point-of-care rapid diagnostic tests (RDT) were used throughout the period of evaluation. A certified Thai Public Health laboratory at Mae Sot Hospital verified RDT positive cases using enzyme-linked immunosorbent assay (ELISA) for HBsAb and HBeAg. Risk factors for hepatitis B were identified by data linkage to antenatal care records. There were 523 (8.5%) RDT positive for HBsAg among 6158 women tested (Aug-2012 to April-2014). Of these 373 (96.9%) of 385 sent for confirmation were positive by ELISA i.e. RDT false positive rate of 3.1% (95% CI 1.7- 5.4). The overall confirmed HbsAg prevalence was 8.3% (511/6158) (95% CI 7.6-9.0). HBeAg prevalence was 32.7% (114/350) (95% CI 27.9-37.7) of cases tested. Risk factors for HBsAg positivity included age >25 years (OR 1.24, CI 1.03-1.49, p 0.021) and Karen heritage (OR 1.73, CI 1.39-2.15, p < 0.01). High hepatitis B seroprevalence amongst migrants and refugees accessing SMRU antenatal services likely reflects that of Kayin State, Myanmar, and perinatal prevention programs are required. False positive cases with HBsAg RDT complicate what is theoretically a straightforward screening.

  2. Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.

    PubMed

    Libert, Diane; Procop, Gary W; Ansari, Mohammad Q

    2018-03-07

    Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.

  3. Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.

    PubMed

    Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne

    2010-01-01

    Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.

  4. Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System

    PubMed Central

    Tyagi, Surabhi; Tyagi, Alok

    2013-01-01

    Background: Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. Aim: To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. Material and Methods: All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti–HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme–linked immunosorbent assay (ELISA) technique using micro–elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. Statistical Analysis: The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Results: Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Conclusion: Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think…. PMID:24179900

  5. Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System.

    PubMed

    Tyagi, Surabhi; Tyagi, Alok

    2013-09-01

    Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti-HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme-linked immunosorbent assay (ELISA) technique using micro-elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think….

  6. Mobile colposcopy in urban and underserved suburban areas in Baja California

    NASA Astrophysics Data System (ADS)

    Madiedo, Marta; Contreras, Sonia; Villalobos, Octavio; Kahn, Bruce S.; Safir, Amit; Levitz, David

    2016-03-01

    Cervical cancer is the leading cause of cancer death for women in low resource settings, often affecting the most economically disenfranchised segment of the population. The key challenge with cervical cancer is the lack of an effective screening program for many of the at-risk, difficult-to-reach women. Outreach programs that utilize mobile clinics to increase access to screening and care in Baja California have been developed. However, many barriers such as quality assurance, efficient referral remained a challenge in this region. Visualization-based co-tests together with cytology (Pap smears) as a primary screen have been proposed. Here, the mobile colposcope of the enhanced visual assessment (EVA) is used to capture an image immediately following a Pap smear. EVA images were reviewed by expert colposcopists. Initial or preliminary data from pilot services showed that Pap false positives and Pap false negatives maybe reduced by expert review of EVA images. This suggests that reviewing of EVA images may be instrumental in catching inaccurate Pap results, thereby improving care. Thus, there is a need to further explore the benefits of using EVA as additional information when conducting Pap smear screenings.

  7. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy

    PubMed Central

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-01-01

    Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622

  8. Non-animal photosafety assessment approaches for cosmetics based on the photochemical and photobiochemical properties.

    PubMed

    Onoue, Satomi; Suzuki, Gen; Kato, Masashi; Hirota, Morihiko; Nishida, Hayato; Kitagaki, Masato; Kouzuki, Hirokazu; Yamada, Shizuo

    2013-12-01

    The main purpose of the present study was to establish a non-animal photosafety assessment approach for cosmetics using in vitro photochemical and photobiochemical screening systems. Fifty-one cosmetics, pharmaceutics and other chemicals were selected as model chemicals on the basis of animal and/or clinical photosafety information. The model chemicals were assessed in terms of photochemical properties by UV/VIS spectral analysis, reactive oxygen species (ROS) assay and 3T3 neutral red uptake phototoxicity testing (3T3 NRU PT). Most phototoxins exhibited potent UV/VIS absorption with molar extinction coefficients of over 1000M(-1)cm(-1), although false-negative prediction occurred for 2 cosmetic phototoxins owing to weak UV/VIS absorption. Among all the cosmetic ingredients, ca. 42% of tested chemicals were non-testable in the ROS assay because of low water solubility; thereby, micellar ROS (mROS) assay using a solubilizing surfactant was employed for follow-up screening. Upon combination use of ROS and mROS assays, the individual specificity was 88.2%, and the positive and negative predictivities were estimated to be 94.4% and 100%, respectively. In the 3T3 NRU PT, 3 cosmetics and 4 drugs were incorrectly predicted not to be phototoxic, although some of them were typical photoallergens. Thus, these in vitro screening systems individually provide false predictions; however, a systematic tiered approach using these assays could provide reliable photosafety assessment without any false-negatives. The combined use of in vitro assays might enable simple and fast non-animal photosafety evaluation of cosmetic ingredients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Detection of Sickle Cell Hemoglobin in Haiti by Genotyping and Hemoglobin Solubility Tests

    PubMed Central

    Carter, Tamar E.; von Fricken, Michael; Romain, Jean R.; Memnon, Gladys; St. Victor, Yves; Schick, Laura; Okech, Bernard A.; Mulligan, Connie J.

    2014-01-01

    Sickle cell disease is a growing global health concern because infants born with the disorder in developing countries are now surviving longer with little access to diagnostic and management options. In Haiti, the current state of sickle cell disease/trait in the population is unclear. To inform future screening efforts in Haiti, we assayed sickle hemoglobin mutations using traditional hemoglobin solubility tests (HST) and add-on techniques, which incorporated spectrophotometry and insoluble hemoglobin separation. We also generated genotype data as a metric for HST performance. We found 19 of 202 individuals screened with HST were positive for sickle hemoglobin, five of whom did not carry the HbS allele. We show that spectrophotometry and insoluble hemoglobin separation add-on techniques could resolve false positives associated with the traditional HST approach, with some limitations. We also discuss the incorporation of insoluble hemoglobin separation observation with HST in suboptimal screening settings like Haiti. PMID:24957539

  10. Feline focus: Diagnostic testing for feline thyroid disease: hyperthyroidism.

    PubMed

    Peterson, Mark E

    2013-08-01

    In older cats presenting with clinical features of hyperthyroidism, confirming the diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests, especially when used for routine screening of large numbers of asymptomatic cats. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a high serum thyroxine (T4) value is found in a cat that lacks clinical signs of hyperthyroidism, or if hyperthyroidism is suspected in a cat with normal total T4 concentrations, repeating the total T4 analysis, determining the free T4 concentration, or performing thyroid scintigraphy may be needed to confirm the diagnosis.

  11. Age differences in accuracy and choosing in eyewitness identification and face recognition.

    PubMed

    Searcy, J H; Bartlett, J C; Memon, A

    1999-05-01

    Studies of aging and face recognition show age-related increases in false recognitions of new faces. To explore implications of this false alarm effect, we had young and senior adults perform (1) three eye-witness identification tasks, using both target present and target absent lineups, and (2) and old/new recognition task in which a study list of faces was followed by a test including old and new faces, along with conjunctions of old faces. Compared with the young, seniors had lower accuracy and higher choosing rates on the lineups, and they also falsely recognized more new faces on the recognition test. However, after screening for perceptual processing deficits, there was no age difference in false recognition of conjunctions, or in discriminating old faces from conjunctions. We conclude that the false alarm effect generalizes to lineup identification, but does not extend to conjunction faces. The findings are consistent with age-related deficits in recollection of context and relative age invariance in perceptual integrative processes underlying the experience of familiarity.

  12. Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens.

    PubMed

    Bohaychuk, Valerie M; Gensler, Gary E; King, Robin K; Wu, John T; McMullen, Lynn M

    2005-12-01

    Rapid and molecular technologies such as enzyme-linked immunosorbent assay (ELISA), PCR, and lateral flow immunoprecipitation can reduce the time and labor involved in screening food products for the presence of pathogens. These technologies were compared with conventional culture methodology for the detection of Salmonella, Campylobacter, Listeria, and Escherichia coli O157:H7 inoculated in raw and processed meat and poultry products. Recommended protocols were modified so that the same enrichment broths used in the culture methods were also used in the ELISA, PCR, and lateral flow immunoprecipitation assays. The percent agreement between the rapid technologies and culture methods ranged from 80 to 100% depending on the pathogen detected and the method used. ELISA, PCR, and lateral flow immunoprecipitation all performed well, with no statistical difference, compared with the culture method for the detection of E. coli O157:H7. ELISA performed better for the detection of Salmonella, with sensitivity and specificity rates of 100%. PCR performed better for the detection of Campylobacter jejuni, with 100% agreement to the culture method. PCR was highly sensitive for the detection of all the foodborne pathogens tested except Listeria monocytogenes. Although the lateral flow immunoprecipitation tests were statistically different from the culture methods for Salmonella and Listeria because of false-positive results, the tests did not produce any false negatives, indicating that this method would be suitable for screening meat and poultry products for these pathogens.

  13. Screening method to evaluate point-of-care human chorionic gonadotropin (hCG) devices for susceptibility to the hook effect by hCG β core fragment: evaluation of 11 devices.

    PubMed

    Nerenz, Robert D; Song, Haowei; Gronowski, Ann M

    2014-04-01

    The predominant hCG variant in urine, hCG β core fragment (hCGβcf), has been demonstrated to cause false-negative results in qualitative point-of-care (POC) hCG devices. This is a major concern for healthcare professionals using POC pregnancy tests. We developed a screening method to evaluate qualitative POC hCG devices for their susceptibility to inhibition by hCGβcf. Using this method, we evaluated the performance of 11 commonly used devices. A wide range of purified hCG and hCGβcf concentrations were mixed and tested on 2 POC devices. By use of those results, a screening method was defined and 9 additional POC devices were evaluated. Two solutions containing (a) 500 pmol/L (171 IU/L) intact hCG with 0 pmol/L hCGβcf and (b) 500 pmol/L intact hCG with 500 000 pmol/L hCGβcf were used to screen all POC devices. The OSOM and Cen-Med Elite devices were found to be most susceptible to false-negative results due to hCGβcf. The BC Icon 20 and the Alere were the least susceptible. The remaining 7 were moderately affected. Devices that gave the strongest signal with hCGβcf alone were those that were least likely to show a hook effect. The screening method put forth here can be used by device users and manufacturers to evaluate POC devices for inhibition by hCGβcf. Of 11 devices evaluated, only 2 have been identified that exhibit minimal to no susceptibility to hCGβcf.

  14. Engaging Patients in Decisions About Cancer Screening: Exploring the Decision Journey Through the Use of a Patient Portal.

    PubMed

    Woolf, Steven H; Krist, Alex H; Lafata, Jennifer Elston; Jones, Resa M; Lehman, Rebecca R; Hochheimer, Camille J; Sabo, Roy T; Frosch, Dominick L; Zikmund-Fisher, Brian J; Longo, Daniel R

    2018-02-01

    Engaging patients to make informed choices is paramount but difficult in busy practices. This study sought to engage patients outside the clinical setting to better understand how they approach cancer screening decisions, including their primary concerns and their preferences for finalizing their decision. Twelve primary care practices offering patients an online personal health record invited eligible patients to complete a 17-item online interactive module. Among 11,458 registered users, invitations to complete the module were sent to adults aged 50-74 years who were overdue for colorectal cancer screening and to women aged 40-49 years and men aged 55-69 who had not undergone a recent mammogram or prostate-specific antigen test, respectively. The module was started by 2,355 patients and completed by 903 patients. Most respondents (76.8%) knew they were eligible for screening. Preferred next steps were talking to the clinician (76.6%), reading/research (28.6%), and consulting trusted friends/family (16.4%). Priority topics included how much screening improves life expectancy, comparative test performance, and the prevalence/health risks of the cancer. Leading fears were getting cancer/delayed detection (79.2%), abnormal results (40.5%), and testing complications (39.1%), the last referring to false test results, medical complications, or unnecessary treatments. Men eligible for prostate-specific antigen screening were more likely than women eligible for mammography to express concerns about testing complications and to prioritize weighing pros and cons over gut feelings (p<0.05). Although this sample was predisposed to screening, most patients wanted help in finalizing their decision. Many wanted to weigh the pros and cons and expressed fears of potential harms from screening. Understanding how patients approach decisions may help design more effective engagement strategies. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Estimated number of infants detected and missed by critical congenital heart defect screening.

    PubMed

    Ailes, Elizabeth C; Gilboa, Suzanne M; Honein, Margaret A; Oster, Matthew E

    2015-06-01

    In 2011, the US Secretary of Health and Human Services recommended universal screening of newborns for critical congenital heart defects (CCHDs), yet few estimates of the number of infants with CCHDs likely to be detected through universal screening exist. Our objective was to estimate the number of infants with nonsyndromic CCHDs in the United States likely to be detected (true positives) and missed (false negatives) through universal newborn CCHD screening. We developed a simulation model based on estimates of birth prevalence, prenatal diagnosis, late detection, and sensitivity of newborn CCHD screening through pulse oximetry to estimate the number of true-positive and false-negative nonsyndromic cases of the 7 primary and 5 secondary CCHD screening targets identified through screening. We estimated that 875 (95% uncertainty interval [UI]: 705-1060) US infants with nonsyndromic CCHDs, including 470 (95% UI: 360-585) infants with primary CCHD screening targets, will be detected annually through newborn CCHD screening. An additional 880 (UI: 700-1080) false-negative screenings, including 280 (95% UI: 195-385) among primary screening targets, are expected. We estimated that similar numbers of CCHDs would be detected under scenarios comparing "lower" (∼19%) and "higher" (∼41%) than current prenatal detection prevalences. A substantial number of nonsyndromic CCHD cases are likely to be detected through universal CCHD screening; however, an equal number of false-negative screenings, primarily among secondary targets of screening, are likely to occur. Future efforts should document the true impact of CCHD screening in practice. Copyright © 2015 by the American Academy of Pediatrics.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, Joshua D.; Hartse, Hans

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  17. Gender disparities in screening for congenital hypothyroidism using thyroxine as a primary screen.

    PubMed

    DeMartino, Lenore; McMahon, Rebecca; Caggana, Michele; Tavakoli, Norma Parvin

    2018-06-26

    Newborn screening for congenital hypothyroidism (CH) is based on testing for the markers thyroxine (T4) and/or thyroid stimulating hormone (TSH). Diagnosis of CH is complicated because many factors affect the levels of these hormones including infant birth weight, prematurity, and age at specimen collection. We investigated whether the sex of the newborn affected the levels of T4 and TSH and consequently the outcome of newborn screening. In New York State, the Newborn Screening program initially tests all infants for T4 and any baby with a result in the lowest 10% is triaged for TSH screening. We analyzed data from 2008 to 2016 to determine mean and median T4 and TSH values and how these results correlate with the sex of infants who are reported as borderline, referred and confirmed with CH. T4 and TSH concentrations in dried blood spots were measured using commercially available fluoroimmunoassays. From 2008 to 2016, of the 2.4 million specimens tested for thyroxine, 51.5% were from male and 48.5% were from female infants. Male infants constituted 60% of specimens triaged for TSH testing, 64.9% of repeat requests and 59.6% of referrals, but only 49% of confirmed CH cases. The mean and median T4 values were lower (a difference of approximately 0.8-1.1 μg/dL each year), and the median TSH values were higher in male compared to female infants. Natural differences in thyroid hormone levels in male and female infants leads to male infants being disproportionately represented in the false positive category.

  18. Technologic advances for evaluation of cervical cytology: is newer better?

    PubMed

    Hartmann, K E; Nanda, K; Hall, S; Myers, E

    2001-12-01

    Among those women who have cervical cancer and have been screened, 14% to 33% of the cases represent failure to detect abnormalities that existed at the time of screening. New technologies intended to improve detection of cytologic abnormalities include liquid-based, thin-layer cytology (ThinPrep, AutoCyte), computerized rescreening (PAPNET), and algorithm-based computer rescreening (AutoPap). This report combines evidence reviews conducted for the U.S. Preventive Services Task Force and the Agency for Healthcare Research and Quality, in which we systematically identified articles on cervical neoplasia, cervical dysplasia, and screening published between January 1966 and March 2001. We note the challenges for improving screening methods, providing an overview of methods for collecting and evaluating cytologic samples, and examining the evidence about the diagnostic performance of new technologies for detecting cervical lesions. Using standard criteria for evaluation of the diagnostic tests, we determined that knowledge about the sensitivity, specificity, and predictive values of new technologies is meager. Only one study of liquid-based cytology used a reference standard of colposcopy, with histology as indicated, to assess participants with normal screening results. Lack of an adequate reference standard is the overwhelming reason that test characteristics cannot be properly assessed or compared. Most publications compare results of screening using the new technology with expert panel review of the cytologic specimen. In that case, the tests are not independent measures and do nothing to relate the screening test findings to the true status of the cervix, making determination of false-negatives, and thus sensitivity, specificity, and negative predictive value, impossible. We did not identify any literature about health outcomes or cost effectiveness of using these tools in a system of screening. For the purposes of guiding decision making about choice of screening tools, the current evidence is inadequate to gauge whether new technologies are "better" than conventional cytology..

  19. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy.

    PubMed

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-11-27

    To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Performance of Spectrogram-Based Seizure Identification of Adult EEGs by Critical Care Nurses and Neurophysiologists.

    PubMed

    Amorim, Edilberto; Williamson, Craig A; Moura, Lidia M V R; Shafi, Mouhsin M; Gaspard, Nicolas; Rosenthal, Eric S; Guanci, Mary M; Rajajee, Venkatakrishna; Westover, M Brandon

    2017-07-01

    Continuous EEG screening using spectrograms or compressed spectral arrays (CSAs) by neurophysiologists has shorter review times with minimal loss of sensitivity for seizure detection when compared with visual analysis of raw EEG. Limited data are available on the performance characteristics of CSA-based seizure detection by neurocritical care nurses. This is a prospective cross-sectional study that was conducted in two academic neurocritical care units and involved 33 neurointensive care unit nurses and four neurophysiologists. All nurses underwent a brief training session before testing. Forty two-hour CSA segments of continuous EEG were reviewed and rated for the presence of seizures. Two experienced clinical neurophysiologists masked to the CSA data performed conventional visual analysis of the raw EEG and served as the gold standard. The overall accuracy was 55.7% among nurses and 67.5% among neurophysiologists. Nurse seizure detection sensitivity was 73.8%, and the false-positive rate was 1-per-3.2 hours. Sensitivity and false-alarm rate for the neurophysiologists was 66.3% and 1-per-6.4 hours, respectively. Interrater agreement for seizure screening was fair for nurses (Gwet AC1 statistic: 43.4%) and neurophysiologists (AC1: 46.3%). Training nurses to perform seizure screening utilizing continuous EEG CSA displays is feasible and associated with moderate sensitivity. Nurses and neurophysiologists had comparable sensitivities, but nurses had a higher false-positive rate. Further work is needed to improve sensitivity and reduce false-alarm rates.

  1. Contamination of dried blood spots - an underestimated risk in newborn screening.

    PubMed

    Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia

    2018-01-26

    Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.

  2. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  3. Effect of screening on ovarian cancer mortality: the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Randomized Controlled Trial.

    PubMed

    Buys, Saundra S; Partridge, Edward; Black, Amanda; Johnson, Christine C; Lamerato, Lois; Isaacs, Claudine; Reding, Douglas J; Greenlee, Robert T; Yokochi, Lance A; Kessel, Bruce; Crawford, E David; Church, Timothy R; Andriole, Gerald L; Weissfeld, Joel L; Fouad, Mona N; Chia, David; O'Brien, Barbara; Ragard, Lawrence R; Clapp, Jonathan D; Rathmell, Joshua M; Riley, Thomas L; Hartge, Patricia; Pinsky, Paul F; Zhu, Claire S; Izmirlian, Grant; Kramer, Barnett S; Miller, Anthony B; Xu, Jian-Lun; Prorok, Philip C; Gohagan, John K; Berg, Christine D

    2011-06-08

    Screening for ovarian cancer with cancer antigen 125 (CA-125) and transvaginal ultrasound has an unknown effect on mortality. To evaluate the effect of screening for ovarian cancer on mortality in the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Trial. Randomized controlled trial of 78,216 women aged 55 to 74 years assigned to undergo either annual screening (n = 39,105) or usual care (n = 39,111) at 10 screening centers across the United States between November 1993 and July 2001. Intervention The intervention group was offered annual screening with CA-125 for 6 years and transvaginal ultrasound for 4 years. Participants and their health care practitioners received the screening test results and managed evaluation of abnormal results. The usual care group was not offered annual screening with CA-125 for 6 years or transvaginal ultrasound but received their usual medical care. Participants were followed up for a maximum of 13 years (median [range], 12.4 years [10.9-13.0 years]) for cancer diagnoses and death until February 28, 2010. Mortality from ovarian cancer, including primary peritoneal and fallopian tube cancers. Secondary outcomes included ovarian cancer incidence and complications associated with screening examinations and diagnostic procedures. Ovarian cancer was diagnosed in 212 women (5.7 per 10,000 person-years) in the intervention group and 176 (4.7 per 10,000 person-years) in the usual care group (rate ratio [RR], 1.21; 95% confidence interval [CI], 0.99-1.48). There were 118 deaths caused by ovarian cancer (3.1 per 10,000 person-years) in the intervention group and 100 deaths (2.6 per 10,000 person-years) in the usual care group (mortality RR, 1.18; 95% CI, 0.82-1.71). Of 3285 women with false-positive results, 1080 underwent surgical follow-up; of whom, 163 women experienced at least 1 serious complication (15%). There were 2924 deaths due to other causes (excluding ovarian, colorectal, and lung cancer) (76.6 per 10,000 person-years) in the intervention group and 2914 deaths (76.2 per 10,000 person-years) in the usual care group (RR, 1.01; 95% CI, 0.96-1.06). Among women in the general US population, simultaneous screening with CA-125 and transvaginal ultrasound compared with usual care did not reduce ovarian cancer mortality. Diagnostic evaluation following a false-positive screening test result was associated with complications. Trial Registration clinicaltrials.gov Identifier: NCT00002540.

  4. Drawing a Close to the Use of Human Figure Drawings as a Projective Measure of Intelligence

    PubMed Central

    Imuta, Kana; Scarf, Damian; Pharo, Henry; Hayne, Harlene

    2013-01-01

    The practice of using children's human figure drawings (HFDs) to assess their intellectual ability is pervasive among psychologists and therapists in many countries. Since the first systematic scoring system for HFDs was published in 1926, their continued popularity has led to the development of several revised versions of the test. Most recently, the Draw-A-Person Intellectual Ability Test for children, adolescents, and adults (DAP:IQ) was published. It is the most up-to-date form of HFD test designed to assess intellectual functioning across a wide age range. In the present study, we assessed the validity of the DAP:IQ as a screening measure of intelligence in both children and adults. In Experiment 1, 100 4- to 5-year-old children completed the DAP:IQ and the Wechsler Preschool and Primary Scale of Intelligence-Third Edition. In Experiment 2, 100 adults completed the DAP:IQ and the Wechsler Abbreviated Scale of Intelligence. In both experiments, we found only weak to modest correlations between scores on the DAP:IQ and the Wechsler tests. Furthermore, when we compared individual's scores on the two tests, the DAP:IQ yielded high false positive and false negative rates when screening for borderline and superior intellectual functioning. Based on these findings, and based on the lack of validity of previous HFD tests, we conclude that practitioners should not rely on HFD tests as a projective measure of intelligence. PMID:23516590

  5. Drawing a close to the use of human figure drawings as a projective measure of intelligence.

    PubMed

    Imuta, Kana; Scarf, Damian; Pharo, Henry; Hayne, Harlene

    2013-01-01

    The practice of using children's human figure drawings (HFDs) to assess their intellectual ability is pervasive among psychologists and therapists in many countries. Since the first systematic scoring system for HFDs was published in 1926, their continued popularity has led to the development of several revised versions of the test. Most recently, the Draw-A-Person Intellectual Ability Test for children, adolescents, and adults (DAP:IQ) was published. It is the most up-to-date form of HFD test designed to assess intellectual functioning across a wide age range. In the present study, we assessed the validity of the DAP:IQ as a screening measure of intelligence in both children and adults. In Experiment 1, 100 4- to 5-year-old children completed the DAP:IQ and the Wechsler Preschool and Primary Scale of Intelligence-Third Edition. In Experiment 2, 100 adults completed the DAP:IQ and the Wechsler Abbreviated Scale of Intelligence. In both experiments, we found only weak to modest correlations between scores on the DAP:IQ and the Wechsler tests. Furthermore, when we compared individual's scores on the two tests, the DAP:IQ yielded high false positive and false negative rates when screening for borderline and superior intellectual functioning. Based on these findings, and based on the lack of validity of previous HFD tests, we conclude that practitioners should not rely on HFD tests as a projective measure of intelligence.

  6. Hepatitis B Virus Blood Screening: Need for Reappraisal of Blood Safety Measures?

    PubMed Central

    Candotti, Daniel; Laperche, Syria

    2018-01-01

    Over the past decades, the risk of HBV transfusion–transmission has been steadily reduced through the recruitment of volunteer donors, the selection of donors based on risk-behavior evaluation, the development of increasingly more sensitive hepatitis B antigen (HBsAg) assays, the use of hepatitis B core antibody (anti-HBc) screening in some low-endemic countries, and the recent implementation of HBV nucleic acid testing (NAT). Despite this accumulation of blood safety measures, the desirable zero risk goal has yet to be achieved. The residual risk of HBV transfusion–transmission appears associated with the preseroconversion window period and occult HBV infection characterized by the absence of detectable HBsAg and extremely low levels of HBV DNA. Infected donations tested false-negative with serology and/or NAT still persist and derived blood components were shown to transmit the virus, although rarely. Questions regarding the apparent redundancy of some safety measures prompted debates on how to reduce the cost of HBV blood screening. In particular, accumulating data strongly suggests that HBsAg testing may add little, if any HBV risk reduction value when HBV NAT and anti-HBc screening also apply. Absence or minimal acceptable infectious risk needs to be assessed before considering discontinuing HBsAg. Nevertheless, HBsAg remains essential in high-endemic settings where anti-HBc testing cannot be implemented without compromising blood availability. HBV screening strategy should be decided according to local epidemiology, estimate of the infectious risk, and resources. PMID:29515997

  7. Assessment of the contents related to screening on Portuguese language websites providing information on breast and prostate cancer.

    PubMed

    Ferreira, Daniel; Carreira, Helena; Silva, Susana; Lunet, Nuno

    2013-11-01

    The objective of this study was to assess the quality of the contents related to screening in a sample of websites providing information on breast and prostate cancer in the Portuguese language. The first 200 results of each cancer-specific Google search were considered. The accuracy of the screening contents was defined in accordance with the state of the art, and its readability was assessed. Most websites mentioned mammography as a method for breast cancer screening (80%), although only 28% referred to it as the only recommended method. Almost all websites mentioned PSA evaluation as a possible screening test, but correct information regarding its effectiveness was given in less than 10%. For both breast and prostate cancer screening contents, the potential for overdiagnosis and false positive results was seldom addressed, and the median readability index was approximately 70. There is ample margin for improving the quality of websites providing information on breast and prostate cancer in Portuguese.

  8. [Evaluation of quality of HIV diagnostic procedures in Poland].

    PubMed

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  9. Effectiveness of the critical congenital heart disease screening program for early diagnosis of cardiac abnormalities in newborn infants.

    PubMed

    Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B

    2017-10-01

    To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants.  Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at  Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.

  10. Cytology versus HPV testing for cervical cancer screening in the general population.

    PubMed

    Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc

    2017-08-10

    Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.

  11. Current Status of Testing for Microdeletion Syndromes and Rare Autosomal Trisomies Using Cell-Free DNA Technology.

    PubMed

    Yaron, Yuval; Jani, Jacques; Schmid, Maximilian; Oepkes, Dick

    2015-11-01

    Noninvasive prenatal testing using cell-free DNA in maternal blood for trisomy 21 was introduced in 2011. This technology has continuously evolved with the addition of screening for trisomy 18 and trisomy 13 followed by the inclusion of sex chromosome aneuploidies. Expanded noninvasive prenatal test panels have recently become available, which enable screening for microdeletion syndromes such as the 22q11.2 deletion (associated with the velocardiofacial syndrome) and others. However, the performance data for these microdeletion syndromes are derived from a small number of samples, mostly generated in vitro. Rigorous performance evaluation, as was done at least for trisomy 21 testing using cell-free DNA analysis, is difficult to perform given the rarity of each condition. In addition, detection rates may vary considerably depending on deletion size. Importantly, positive predictive values (PPVs), strongly influenced by the low prevalence, are expected to be significantly lower than 10% for most conditions. Thus, screening in an average-risk population is likely to have many more false-positives than affected cases detected. Conversely, testing in a high-risk population such as fetuses with cardiac anomalies may have higher PPVs, but a negative result needs to be considered carefully as a result of uncertain information about detection rates and a significant residual risk for other copy number variants and single gene disorders. This article integrates current knowledge on cell-free DNA testing for microdeletions with the aim to assist clinicians and policymakers in designing optimal programs for screening in pregnancy.

  12. The prevalence, population structure and screening test specificity of penicillin-susceptible Staphylococcus aureus bacteremia isolates in Malmö, Sweden.

    PubMed

    Resman, Fredrik; Thegerström, John; Månsson, Fredrik; Ahl, Jonas; Tham, Johan; Riesbeck, Kristian

    2016-08-01

    The objectives of this study were to examine the prevalence of penicillin-susceptible bacteremic Staphylococcus aureus in the Malmö area in 2014, to re-evaluate the phenotypic methods of penicillinase detection on these isolates, and to investigate the clonal distribution of penicillin-susceptible isolates. All non-redundant S. aureus from blood in the Malmö catchment area in southern Sweden 2014 were screened for penicillin susceptibility using PcG 1U disk diffusion, E-test PcG and the nitrocefin test. All isolates screened as likely susceptible were subjected to PCR for detection of penicillinase (blaZ) and spa-typing. Almost one out of three bacteremic isolates (80/257; 31.1%) were susceptible to penicillin. All screening methods except for the nitrocefin test alone had a low proportion of isolates falsely tested as susceptible, but no method used in the study had perfect specificity compared with PCR. Penicillin-susceptible isolates had a distinct phylogenetic distribution, and two clonal complexes (CC5 and CC45) constituted half of the isolates. Almost one third of S. aureus isolated from blood in southern Sweden in 2014 was susceptible to penicillin. Considering that intravenous penicillin has theoretical advantages compared with the standard treatment in the study area, we argue that routine testing of penicillin susceptibility should be reconsidered. Copyright © 2016 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  13. Screening for cystic fibrosis in New York State: considerations for algorithm improvements.

    PubMed

    Kay, Denise M; Maloney, Breanne; Hamel, Rhonda; Pearce, Melissa; DeMartino, Lenore; McMahon, Rebecca; McGrath, Emily; Krein, Lea; Vogel, Beth; Saavedra-Matiz, Carlos A; Caggana, Michele; Tavakoli, Norma P

    2016-02-01

    Newborn screening for cystic fibrosis (CF), a chronic progressive disease affecting mucus viscosity, has been beneficial in both improving life expectancy and the quality of life for individuals with CF. In New York State from 2007 to 2012 screening for CF involved measuring immunoreactive trypsinogen (IRT) levels in dried blood spots from newborns using the IMMUCHEM(™) Blood Spot Trypsin-MW ELISA kit. Any specimen in the top 5% IRT level underwent DNA analysis using the InPlex(®) CF Molecular Test. Of the 1.48 million newborns screened during the 6-year time period, 7631 babies were referred for follow-up. CF was confirmed in 251 cases, and 94 cases were diagnosed with CF transmembrane conductance regulated-related metabolic syndrome or possible CF. Nine reports of false negatives were made to the program. Variation in daily average IRT was observed depending on the season (4-6 ng/ml) and kit lot (<3 ng/ml), supporting the use of a floating cutoff. The screening method had a sensitivity of 96.5%, specificity of 99.6%, positive predictive value of 4.5%, and negative predictive value of 99.5%. Considerations for CF screening algorithms should include IRT variations resulting from age at specimen collection, sex, race/ethnicity, season, and manufacturer kit lots. Measuring IRT level in dried blood spots is the first-tier screen for CF. Current algorithms for CF screening lead to substantial false-positive referral rates. IRT values were affected by age of infant when specimen is collected, race/ethnicity and sex of infant, and changes in seasons and manufacturer kit lots The prevalence of CF in NYS is 1 in 4200 with the highest prevalence in White infants (1 in 2600) and the lowest in Black infants (1 in 15,400).

  14. DuPont qualicon BAX system real-time PCR assay for Escherichia coli O157:H7.

    PubMed

    Burns, Frank; Fleck, Lois; Andaloro, Bridget; Davis, Eugene; Rohrbeck, Jeff; Tice, George; Wallace, Morgan

    2011-01-01

    Evaluations were conducted to test the performance of the BAX System Real-Time PCR assay, which was certified as Performance Tested Method 031002 for screening E. coli O157:H7 in ground beef, beef trim, spinach, and lettuce. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the FDA-BAM and the USDA-FSIS culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affect the performance of the assay. An accelerated shelf life study determined an initial 36 month shelf life for the test kit.

  15. Screening for Autism Spectrum Disorders in Children With Down Syndrome

    PubMed Central

    DiGuiseppi, Carolyn; Hepburn, Susan; Davis, Jonathan M.; Fidler, Deborah J.; Hartway, Sara; Lee, Nancy Raitano; Miller, Lisa; Ruttenber, Margaret; Robinson, Cordelia

    2015-01-01

    Objective We assessed the prevalence of autism spectrum disorders (ASD) and screening test characteristics in children with Down syndrome. Method Eligible children born in a defined geographic area between January 1, 1996, and December 31, 2003, were recruited through a population-based birth defects registry and community outreach, then screened with the modified checklist for autism in toddlers or social communication questionnaire, as appropriate. Screen-positive children and a random sample of screen-negative children underwent developmental evaluation. Results We screened 123 children (27.8% of the birth cohort). Mean age was 73.4 months (range, 31–142). Compared to screen-negative children, screen-positive children had similar sociodemo-graphic characteristics but a lower mean developmental quotient (mean difference: 11.0; 95% confidence interval: 4.8–17.3). Weighted prevalences of autistic disorder and total ASD were 6.4% (95% confidence interval [CI]: 2.6%–11.6%) and 18.2% (95% CI: 9.7%–26.8%), respectively. The estimated minimum ASD prevalence, accounting for unscreened children, is 5.1% (95% CI: 3.3%–7.4%). ASD prevalence increased with greater cognitive impairment. Screening test sensitivity was 87.5% (95% CI: 66.6%–97.7%); specificity was 49.9% (95% CI: 37.0%–61.4%). Conclusion The prevalence of ASD among children with Down syndrome aged 2 to 11 years is substantially higher than in the general population. The modified checklist for autism in toddlers and social communication questionnaire were highly sensitive in children with Down syndrome but could result in many false positive tests if universal screening were implemented using current algorithms. Research needs include development of specific ASD screening algorithms and improved diagnostic discrimination in children with Down syndrome. Timely identification of these co-occurring diagnoses is essential so appropriate interventions can be provided. PMID:20375732

  16. Cancer screening with whole-body PET/CT for healthy asymptomatic people in Japan: re-evaluation of its test validity and radiation exposure.

    PubMed

    Ghotbi, Nader; Iwanaga, Masako; Ohtsuru, Akira; Ogawa, Yoji; Yamashita, Shunichi

    2007-01-01

    The use of Positron Emission Tomography (PET) or PET/CT for voluntary cancer screening of asymptomatic individuals is becoming common in Japan, though the utility of such screening is still controversial. This study estimated the general test validity and effective radiation dose for PET/CT cancer screening of healthy Japanese people by evaluating four standard indices (sensitivity, specificity, positive/negative predictive values), and predictive values with including prevalence for published literature and simulation-based Japanese data. CT and FDG-related dosage data were gathered from the literature and then extrapolated to the scan parameters at a model PET center. We estimated that the positive predictive value was only 3.3% in the use of PET/CT for voluntary cancer screening of asymptomatic Japanese individuals aged 50-59 years old, whose average cancer prevalence was 0.5%. The total effective radiation dose of a single whole-body PET/CT scan was estimated to be 6.34 to 9.48 mSv for the average Japanese individual, at 60 kg body weight. With PET/CT cancer screening in Japan, many healthy volunteers screened as false positive are exposed to at least 6.34 mSv without getting any real benefit. More evaluation concerning the justification of applying PET/CT for healthy people is necessary.

  17. Prenatal screening for fetal aneuploidy in singleton pregnancies.

    PubMed

    Chitayat, David; Langlois, Sylvie; Douglas Wilson, R

    2011-07-01

    To develop a Canadian consensus document on maternal screening for fetal aneuploidy (e.g., Down syndrome and trisomy 18) in singleton pregnancies. Pregnancy screening for fetal aneuploidy started in the mid 1960s, using maternal age as the screening test. New developments in maternal serum and ultrasound screening have made it possible to offer all pregnant patients a non-invasive screening test to assess their risk of having a fetus with aneuploidy to determine whether invasive prenatal diagnostic testing is necessary. This document reviews the options available for non-invasive screening and makes recommendations for Canadian patients and health care workers. To offer non-invasive screening for fetal aneuploidy (trisomy 13, 18, 21) to all pregnant women. Invasive prenatal diagnosis would be offered to women who screen above a set risk cut-off level on non-invasive screening or to pregnant women whose personal, obstetrical, or family history places them at increased risk. Currently available non-invasive screening options include maternal age combined with one of the following: (1) first trimester screening (nuchal translucency, maternal age, and maternal serum biochemical markers), (2) second trimester serum screening (maternal age and maternal serum biochemical markers), or (3) 2-step integrated screening, which includes first and second trimester serum screening with or without nuchal translucency (integrated prenatal screen, serum integrated prenatal screening, contingent, and sequential). These options are reviewed, and recommendations are made. Studies published between 1982 and 2009 were retrieved through searches of PubMed or Medline and CINAHL and the Cochrane Library, using appropriate controlled vocabulary and key words (aneuploidy, Down syndrome, trisomy, prenatal screening, genetic health risk, genetic health surveillance, prenatal diagnosis). Results were restricted to systematic reviews, randomized controlled trials, and relevant observational studies. There were no language restrictions. Searches were updated on a regular basis and incorporated in the guideline to August 2010. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The previous Society of Obstetricians and Gynaecologists of Canada guidelines regarding prenatal screening were also reviewed in developing this clinical practice guideline. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care. This guideline is intended to reduce the number of prenatal invasive procedures done when maternal age is the only indication. This will have the benefit of reducing the numbers of normal pregnancies lost because of complications of invasive procedures. Any screening test has an inherent false-positive rate, which may result in undue anxiety. It is not possible at this time to undertake a detailed cost-benefit analysis of the implementation of this guideline, since this would require health surveillance and research and health resources not presently available; however, these factors need to be evaluated in a prospective approach by provincial and territorial initiatives. RECOMMENDATIONS 1. All pregnant women in Canada, regardless of age, should be offered, through an informed counselling process, the option of a prenatal screening test for the most common clinically significant fetal aneuploidies in addition to a second trimester ultrasound for dating, assessment of fetal anatomy, and detection of multiples. (I-A) 2. Counselling must be non-directive and must respect a woman's right to accept or decline any or all of the testing or options offered at any point in the process. (III-A) 3. Maternal age alone is a poor minimum standard for prenatal screening for aneuploidy, and it should not be used a basis for recommending invasive testing when non-invasive prenatal screening for aneuploidy is available. (II-2A) 4. Invasive prenatal diagnosis for cytogenetic analysis should not be performed without multiple marker screening results except for women who are at increased risk of fetal aneuploidy (a) because of ultrasound findings, (b) because the pregnancy was conceived by in vitro fertilization with intracytoplasmic sperm injection, or (c) because the woman or her partner has a history of a previous child or fetus with a chromosomal abnormality or is a carrier of a chromosome rearrangement that increases the risk of having a fetus with a chromosomal abnormality. (II-2E) 5. At minimum, any prenatal screen offered to Canadian women who present for care in the first trimester should have a detection rate of 75% with no more than a 3% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 6. The minimum standard for women presenting in the second trimester should be a screen that has a detection rate of 75% with no more than a 5% false-positive rate. The performance of the screen should be substantiated by annual audit. (III-B) 7. First trimester nuchal translucency should be interpreted for risk assessment only when measured by sonographers or sonologists trained and accredited for this service and when there is ongoing quality assurance (II-2A), and it should not be offered as a screen without biochemical markers in singleton pregnancies. (I-E) 8. Evaluation of the fetal nasal bone in the first trimester should not be incorporated as a screen unless it is performed by sonographers or sonologists trained and accredited for this service and there is ongoing quality assurance. (II-2E) 9. For women who undertake first trimester screening, second trimester serum alpha fetoprotein screening and/or ultrasound examination is recommended to screen for open neural tube defects. (II-1A) 10. Timely referral and access is critical for women and should be facilitated to ensure women are able to undergo the type of screening test they have chosen as first trimester screening. The first steps of integrated screening (with or without nuchal translucency), contingent, or sequential screening are performed in an early and relatively narrow time window. (II-1A) 11. Ultrasound dating should be performed if menstrual or conception dating is unreliable. For any abnormal serum screen calculated on the basis of menstrual dating, an ultrasound should be done to confirm gestational age. (II-1A) 12. The presence or absence of soft markers or anomalies in the 18- to 20-week ultrasound can be used to modify the a priori risk of aneuploidy established by age or prior screening. (II-2B) 13. Information such as gestational dating, maternal weight, ethnicity, insulin-dependent diabetes mellitus, and use of assisted reproduction technologies should be provided to the laboratory to improve accuracy of testing. (II-2A) 14. Health care providers should be aware of the screening modalities available in their province or territory. (III-B) 15. A reliable system needs to be in place ensuring timely reporting of results. (III-C) 16. Screening programs should be implemented with resources that support audited screening and diagnostic laboratory services, ultrasound, genetic counselling services, patient and health care provider education, and high quality diagnostic testing, as well as resources for administration, annual clinical audit, and data management. In addition, there must be the flexibility and funding to adjust the program to new technology and protocols. (II-3B).

  18. Cell-free fetal DNA versus maternal serum screening for trisomy 21 in pregnant women with and without assisted reproduction technology: a prospective interventional study.

    PubMed

    Costa, Jean-Marc; Letourneau, Alexandra; Favre, Romain; Bidat, Laurent; Belaisch-Allart, Joelle; Jouannic, Jean-Marie; Quarello, Edwin; Senat, Marie-Victoire; Broussin, Bernard; Tsatsaris, Vassilis; Demain, Adèle; Kleinfinger, Pascale; Lohmann, Laurence; Agostini, Hélène; Bouyer, Jean; Benachi, Alexandra

    2018-03-01

    PurposeCell-free DNA (cfDNA) as a primary screening test has been available for years but few studies have addressed this option in a prospective manner. The question is of interest after reports that maternal serum screening (MSS) is less accurate for pregnancies resulting from assisted reproduction technologies (ART) than for spontaneous pregnancies (SP).MethodsA prospective interventional study was designed to address the performances of cfDNA compared with MSS in pregnancies with or without ART. Each patient was offered both MSS and cfDNA testing. The primary analysis cohort ultimately included 794 patients with a spontaneous pregnancy (SP) (n = 472) or pregnancy obtained after ART (n = 322).ResultsOverall, the false-positive rate and positive predictive value were 6.6% and 8.8% for MSS but 0% and 100% for cfDNA. MSS false-positive rate and positive predictive values were clearly poorer in the ART group (11.7% and 2.6%) than in the SP group (3.2% and 21.1%). The global rates of invasive procedures were 1.9% (15/794) with cfDNA but 8.4% (65/794) if MSS alone was proposed.ConclusioncfDNA achieved better performance than MSS in both spontaneous and ART pregnancies, thus decreasing the number of invasive procedures. Our findings suggest that cfDNA should be considered for primary screening, especially in pregnancies obtained after ART.GENETICS in MEDICINE advance online publication, 1 March 2018; doi:10.1038/gim.2018.4.

  19. Prevalence and referral rates in neonatal hearing screening program using two step hearing screening protocol in Chennai - A prospective study.

    PubMed

    Vignesh, S S; Jaya, V; Sasireka, B I; Sarathy, Kamala; Vanthana, M

    2015-10-01

    To estimate the prevalence and referral rates in well born and high risk babies using two step hearing screening protocol with Distortion Product Otoacoustic Emissions (DPOAE) and Automated Auditory Brainstem Response (AABR). A prospective study was carried out on 1405 neonates (983 well born babies and 422 high risk babies) who were screened during May 2013 to January 2015 at Institute of Obstetrics and Gynecology, Madras Medical College, Chennai. All neonates were screened using two step screening protocol. They were initially tested with DPOAE. Referred babies in DPOAE were screened with AABR subsequently. Among 1405 (100%) neonates 983 (69.96%) were well born babies and 422 (30.03%) were high risk babies. Total referral rate in DPOAE was found to be 311 (22.13%) among which 195 (13.87%) were well born babies and 116 (8.25%) were high risk babies. Out of 311 babies 31 (2.20%) babies were referred in AABR screening. In 31 babies referred in AABR 11(0.78%) were from well born group and 20 (1.42%) were from the high risk group. Further diagnostic evaluation of these babies, 2 (0.14%) were confirmed to have hearing loss. This study reveals, the prevalence of congenital hearing loss in our population is 1.42 per 1000 babies. Using two step protocol especially AABR along with DPOAE at the initial level of testing significantly reduces referral rates in new born screening programs. Also AABR decreases the false positive responses hence increasing the efficiency of screening program. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. [Leaflets and websites on colorectal cancer screening and their quality assessment from experts' views].

    PubMed

    Dreier, M; Borutta, B; Seidel, G; Münch, I; Töppich, J; Bitzer, E-M; Dierks, M-L; Walter, U

    2014-03-01

    In Germany, individuals who have statutory health insurance have free access to colorectal cancer (CRC) screening tests, and can choose between a fecal occult blood test and a screening colonoscopy. Evidence-based health information may support informed choices regarding whether or not to undergo CRC screening. The aim of this study was to assess whether the available German information materials on CRC screening meet evidence-based health information standards. A systematic search was made for print media and websites on CRC screening addressed to German people with average CRC risk (search period for print media August 2010, for websites January-March 2012). The identified information was assessed with a newly developed comprehensive list of criteria. In all, 41 print media, including 28 flyers and 13 brochures, and 36 websites were identified and assessed. These materials reported more often the benefits than the risks of CRC screening, and quantified presentations of benefits and risks were less frequently given. Most of the materials called for participation and did not indicate the option to decide whether or not to attend CRC screening. This bias in favor of screening was increased by fear-provoking or downplayed wording. Most materials included false and misleading information. The requirements for evidence-based patient information were currently not met by most of the leaflets and websites in Germany. Feedback was given to the producers of the leaflets including a discussion of the findings. The results may be used to revise existing leaflets or to develop new health information on CRC screening.

  1. Frequency of Unnecessarily Biopsies among Patients with Suspicion of Prostate Cancer in Syrian Men.

    PubMed

    Bachour, Dala-Maria; Chahin, Emil; Al-Fahoum, Sahar

    2015-01-01

    The prevalence of prostate cancer is considered high in many countries, and screening tests are very important in order to detect prostate cancer in its early stages; however false positivity with these screening tests means that a lot of patients undergo unnecessary biopsy, which is an invasive procedure, for the confirmatory test. The purpose of this study was to estimate the frequency of unnecessary biopsy cases in patients referred for prostate biopsy in one of the most important and overload cancer centers in Syria. Retrospective data for a period of four years between January 2009 and December 2012 were collected in Al- Bayrouni University Medical hospital in Damascus, Syria. The patients from whom data were collected were referred to our histopathological department because of elevated prostate specific antigen (PSA) serum or an abnormal digital rectal examination (DRE). All patients underwent prostatic TRUS-guided biopsies. Diagnosis of prostate cancer (PCa) or benign prostatic hyperplasia (BPH) was based on histopathological examination and prostate cancers cases were graded and scored according to the Gleason score system. For the 406 patients referred to biopsy, the mean±SD age was 58.4 ±23.3 years. The mean ± SD PSA level was 49.2±21.5 ng/ ml. Of the total we found 237 patients diagnosed with PCa (58. 4%), 166 patients with BPH (40.9%) and 3 cases were unable to be diagnosed (0.7%) because of biopsy collection errors. Our study shows that a high percentage of patients are undergoing unnecessary biopsy, which suggests that the performed screening tests had a high level of false positive and may need re-evaluation.

  2. High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.

    PubMed

    El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin

    2012-07-01

    Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.

  3. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed Central

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864

  4. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  5. Critical Congenital Heart Disease Screening by Pulse Oximetry in a Neonatal Intensive Care Unit

    PubMed Central

    Manja, Veena; Mathew, Bobby; Carrion, Vivien; Lakshminrusimha, Satyan

    2014-01-01

    Critical congenital heart disease (CCHD) screening is effective in asymptomatic late preterm and term newborn infants with a low false positive rate (0.035%). Objective (1) To compare 2817 NICU discharges before and after implementation of CCHD screening; and (2) to evaluate CCHD screening at < 35 weeks gestation. Methods collection of results of CCHD screening including preductal and postductal SpO2 values. Results During the pre-CCHD screen period, 1247 infants were discharged from the NICU and one case of CCHD was missed. After 3/1/12, 1508 CCHD screens were performed among 1570 discharges and no CCHDs were missed. The preductal and postductal SpO2 values were 98.8±1.4% and 99±1.3% respectively in preterm and 98.9±1.3% and 98.9±1.4% in term infants. Ten infants had false positive screens (10/1508=0.66%). Conclusions Performing universal screening in the NICU is feasible but is associated with a higher false positive rate compared to asymptomatic newborn infants. PMID:25058746

  6. Beyond Mammography: New Frontiers in Breast Cancer Screening

    PubMed Central

    Drukteinis, Jennifer S.; Mooney, Blaise P.; Flowers, Chris I.; Gatenby, Robert A

    2014-01-01

    Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography has also undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including; low dose mammography; contrast enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging and MRI. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual’s age, risk, and breast density. PMID:23561631

  7. How to prevent overdiagnosis.

    PubMed

    Chiolero, Arnaud; Paccaud, Fred; Aujesky, Drahomir; Santschi, Valérie; Rodondi, Nicolas

    2015-01-01

    Overdiagnosis is the diagnosis of an abnormality that is not associated with a substantial health hazard and that patients have no benefit to be aware of. It is neither a misdiagnosis (diagnostic error), nor a false positive result (positive test in the absence of a real abnormality). It mainly results from screening, use of increasingly sensitive diagnostic tests, incidental findings on routine examinations, and widening diagnostic criteria to define a condition requiring an intervention. The blurring boundaries between risk and disease, physicians' fear of missing a diagnosis and patients' need for reassurance are further causes of overdiagnosis. Overdiagnosis often implies procedures to confirm or exclude the presence of the condition and is by definition associated with useless treatments and interventions, generating harm and costs without any benefit. Overdiagnosis also diverts healthcare professionals from caring about other health issues. Preventing overdiagnosis requires increasing awareness of healthcare professionals and patients about its occurrence, the avoidance of unnecessary and untargeted diagnostic tests, and the avoidance of screening without demonstrated benefits. Furthermore, accounting systematically for the harms and benefits of screening and diagnostic tests and determining risk factor thresholds based on the expected absolute risk reduction would also help prevent overdiagnosis.

  8. Role of re-screening of cervical smears in internal quality control.

    PubMed Central

    Baker, A; Melcher, D; Smith, R

    1995-01-01

    AIMS--To investigate the use of rapid re-screening as a quality control method for previously screened cervical slides; to compare this method with 10% random re-screening and clinically indicated double screening. METHODS--Between June 1990 and December 1994, 117,890 negative smears were subjected to rapid re-screening. RESULTS--This study shows that rapid re-screening detects far greater numbers of false negative cases when compared with both 10% random re-screening and clinically indicated double screening, with no additional demand on human resources. The technique also identifies variation in the performance of screening personnel as an additional benefit. CONCLUSION--Rapid re-screening is an effective method of quality control. Although less sensitive, rapid re-screening should replace 10% random re-screening and selected re-screening as greater numbers of false negative results are detected while consuming less resources. PMID:8543619

  9. Breast cancer screening controversies: who, when, why, and how?

    PubMed

    Chetlen, Alison; Mack, Julie; Chan, Tiffany

    2016-01-01

    Mammographic screening is effective in reducing mortality from breast cancer. The issue is not whether mammography is effective, but whether the false positive rate and false negative rates can be reduced. This review will discuss controversies including the reduction in breast cancer mortality, overdiagnosis, the ideal screening candidate, and the optimal imaging modality for breast cancer screening. The article will compare and contrast screening mammography, tomosynthesis, whole-breast screening ultrasound, magnetic resonance imaging, and molecular breast imaging. Though supplemental imaging modalities are being utilized to improve breast cancer diagnosis, mammography still remains the gold standard for breast cancer screening. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Level of visual acuity necessary to avoid false-positives on the HRR and Ishihara color vision tests.

    PubMed

    Ng, Jason S; Shih, Brian

    2017-05-11

    Minimizing false-positives (FPs) when evaluating color vision is important in eye care. Identification of plate 1 (demonstration plate) is often considered a way to avoid FPs. However, few studies have quantified the minimum level of visual acuity (VA) that would minimize FPs for the Ishihara and HRR color tests. Threshold levels of optical defocus were obtained from 25 color normal subjects. Blur levels were obtained for Ishihara (38 plate) plates 1, 10, and 15 and 4th edition HRR plates 1, 7, 10, and 20 using the method of limits. Corresponding VAs were measured through these blur levels at 40 centimeters after adjusting for the dioptric distance difference. Analysis of variance testing was used to analyze the data. Mean optical defocus values in diopters (mean ± SD) for HRR plates 1, 7, 10, and 20 were 6.23 ± 1.61, 1.23 ± 1.16, 2.41 ± 1.31, and 7.96 ± 2.03, respectively, and for Ishihara plates 1, 10, and 15 were 5.70 ± 1.52, 3.68 ± 1.71, and 4.62 ± 1.56, respectively. There was a significant difference between the screening and demonstration plates for both tests (p<0.001). Based on the plate in each test that was found to be the least tolerant to blur, the average minimum VAs needed to identify the screening plates were approximately 20/180 for the Ishihara test and 20/50 for the HRR test. Identifying the demonstration plate in the Ishihara and HRR tests does not ensure FPs will be avoided.

  11. Benefits and harms of CT lung cancer screening strategies. A comparative modeling study for the U.S. Preventive Services Task Force

    PubMed Central

    de Koning, Harry J.; Meza, Rafael; Plevritis, Sylvia K.; Haaf, Kevin ten; Munshi, Vidit N.; Jeon, Jihyoun; Erdogan, Saadet Ayca; Kong, Chung Yin; Han, Summer S.; van Rosmalen, Joost; Choi, Sung Eun; Pinsky, Paul F.; Berrington de Gonzalez, Amy; Berg, Christine D.; Black, William C.; Tammemägi, Martin C.; Hazelton, William D.; Feuer, Eric J.; McMahon, Pamela M.

    2014-01-01

    Background The optimal screening policy for lung cancer is unknown. Objective To identify efficient CT-screening scenarios where relatively more lung cancer deaths are averted for fewer CT screens. Design Comparative modeling study using 5 independent models. Data Sources The National Lung Screening Trial, the Prostate, Lung, Colorectal and Ovarian trial, the Surveillance, Epidemiology, and End Results program, and U.S. Smoking History Generator. Target Population U.S. cohort born in 1950. Time Horizon Cohort followed from ages 45 to 90. Perspective Societal. Intervention 576 scenarios with varying eligibility criteria (age, smoking pack-years, years quit) and screening intervals. Outcome Measures Benefits: lung cancer deaths averted or life-years gained; harms: CT-exams, false positives (including biopsy/surgery), overdiagnosed cases, radiation-related deaths. Results of Best-Case Annual screening from age 55 through 80 for ever-smokers with at least 30 pack-years and ex-smokers with less than 15 years since quitting was the most advantageous strategy. It would lead to 50% (45 to 54%) of cancers being detected at an early stage (I/II); 575 screens per lung cancer death averted; a 14% (8.2 to 23.5%) lung cancer mortality reduction; 497 lung cancer deaths averted; and 5,250 life-years gained per the 100,000-member cohort. Harms would include 67,550 false-positive tests, 910 biopsies or surgeries for benign lesions and 190 overdiagnosed cancers (3.7%; 1.4 to 8.3%). Results of Sensitivity Analysis The number of cancer deaths averted for the scenario varied across models between 177 and 862, and for overdiagnosed cancers between 72 and 426. Limitations Scenarios assumed 100% screening adherence. Data derived from trials with short duration were extrapolated to life-time follow-up. Conclusion Annual CT screening for lung cancer has a favorable benefit-harm ratio for individuals aged 55 through 80 years with 30 or more pack-year exposure to smoking. PMID:24379002

  12. Health perceptions in patients who undergo screening and workup for prostate cancer.

    PubMed

    Katz, David A; Jarrard, David F; McHorney, Colleen A; Hillis, Stephen L; Wiebe, Donald A; Fryback, Dennis G

    2007-02-01

    False-positive screening tests may induce persistent psychological distress. This study was designed to determine whether a positive screening test with negative biopsy findings for prostate cancer is associated with worsened mental health during short-term follow-up. We conducted a cross-sectional telephone survey of two groups of men approximately 2 months after testing: group 1, 109 men with an abnormal prostate-specific antigen level or digital rectal examination findings but with negative biopsy findings for prostate cancer; and group 2, 101 age-matched primary care patients with PSA screening levels in the reference range (less than 4 ng/mL). Primary outcomes included state anxiety and prostate cancer-related worry. Secondary outcomes included Medical Outcomes Study Short Form 36-item Health Survey subscales and sexual function items. Multivariate regression techniques were used to adjust for differences in baseline covariates. Group 1 patients were more worried than group 2 patients about getting prostate cancer (mean worry 3.9 versus 4.5, P = 0.0001, using a 5-point scale, with 1 indicating extreme worry and 5 no worry). Group 1 patients also perceived their risk of prostate cancer to be significantly greater than that of controls (P = 0.001). No significant differences were found across state anxiety or Medical Outcomes Study Short Form 36-item Health Survey subscales. Sexual bother was greater for group 1 patients, with 19% reporting that sexual function was a moderate to big problem compared with 10% of group 2 patients (P = 0.0001). Men with abnormal prostate cancer screening tests report increased cancer-related worry and more problems with sexual function, despite having a negative biopsy result. Effective counseling interventions are needed before prostate cancer screening and during follow-up.

  13. [Use of urine drug screening in the emergency department of a paediatric hospital].

    PubMed

    Ferrer Bosch, Núria; Martínez Sánchez, Lidia; Trenchs Sainz de la Maza, Victoria; Velasco Rodríguez, Jesús; García González, Elsa; Luaces Cubells, Carles

    2018-01-01

    To describe the situations in which urine drug screening is used in a Paediatric Emergency Department (ED). An analysis is also made on its potential usefulness on whether it changes the patient management, and if the results are confirmed by using specific techniques. A retrospective study was conducted on patients under the age of 18 attended in the ED during 2014 and in whom urine drug screening was requested. Depending on the potential capacity of the screening result to change patient management, two groups were defined (potentially useful and not potentially useful). Urine drug screening was performed on a total of 161 patients. The screening was considered not to be potentially useful in 87 (54.0%). This was because the clinical history already explained the symptoms the patient had in 55 (34.1%) patients, in 29 (18.0%) because the patient was asymptomatic, and in 3 (1.9%) because the suspected drug was not detectable in the screening. The drug screening results changed the patient management in 5 (3.1%) cases. A toxic substance was detected in 44 (27.3%). Two out of the 44 that were positive (2.1%) were re-tested by specific techniques, and presence of the toxic substance was ruled out in both of them (false positives). Most of the drug screening tests are not justified, and it is very infrequent that they change patient management. It is very rare that the results are confirmed using more specific methods. Urine drug screening tests should be restricted to particular cases and if the result has legal implications, or if the patient denies using the drug, it should be followed by a specific toxicological study to provide a conclusive result. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Creatine transporter deficiency: prevalence among patients with mental retardation and pitfalls in metabolite screening.

    PubMed

    Arias, Angela; Corbella, Marc; Fons, Carmen; Sempere, Angela; García-Villoria, Judit; Ormazabal, Aida; Poo, Pilar; Pineda, Mercé; Vilaseca, María Antonia; Campistol, Jaume; Briones, Paz; Pàmpols, Teresa; Salomons, Gajja S; Ribes, Antonia; Artuch, Rafael

    2007-11-01

    To report the prevalence of creatine transporter deficiency in males with mental retardation and to study whether a protein-rich food intake might be a potential diagnostic pitfall. We determined creatine/creatinine ratio in urine samples from 1600 unrelated male patients with mental retardation and/or autism. Urine creatine was analyzed by HPLC-MS/MS. Thirty-three of 1600 cases showed increased urine creatine/creatinine ratio. Four out of these thirty-three cases were definitively diagnosed with creatine transporter deficiency, while the other 29 were false positive results. Significantly higher values were observed for urine Cr/Crn ratio in healthy volunteers after a meal based on beef or oily fish as compared to eggs, pasta or salad (Wilcoxon test: p<0.005). False positive results may be observed in biochemical screening for creatine transporter deficiency, and they may be due to intake of meals rich in creatine prior to urine samples analysis.

  15. A Screening Mechanism Differentiating True from False Pain during Empathy.

    PubMed

    Sun, Ya-Bin; Lin, Xiao-Xiao; Ye, Wen; Wang, Ning; Wang, Jin-Yan; Luo, Fei

    2017-09-13

    Empathizing with another's suffering is important in social interactions. Empathic behavior is selectively elicited from genuine, meaningful pain but not from fake, meaningless scenarios. However, the brain's screening mechanism of false information from meaningful events and the time course for the screening process remains unclear. Using EEG combined with principle components analysis (PCA) techniques, here we compared temporal neurodynamics between the observation of pain and no-pain pictures as well as between true (painful expressions and needle-penetrated arms) and false (needle-penetrated faces with neutral expressions) pain pictures. The results revealed that pain vs. no-pain information is differentiated in the very early ERP components, i.e., the N1/P1 for the face and arm pictures categories and the VPP/N170 for the facial expression category while the mid-latency ERP components, N2 and P3, played key roles in differentiating true from false situations. The complex of N2 and P3 components may serve as a screening mechanism through which observers allocate their attentions to more important or relevant events and screen out false environmental information. This is the first study to describe and provide a time course of the screening process during pain empathy. These findings shed new light on the understanding of empathic processing.

  16. Pilot study analyzing automated ECG screening of hypertrophic cardiomyopathy.

    PubMed

    Campbell, Matthew J; Zhou, Xuefu; Han, Chia; Abrishami, Hedayat; Webster, Gregory; Miyake, Christina Y; Sower, Christopher T; Anderson, Jeffrey B; Knilans, Timothy K; Czosek, Richard J

    2017-06-01

    Hypertrophic cardiomyopathy (HCM) is one of the leading causes of sudden cardiac death in athletes. However, preparticipation ECG screening has often been criticized for failing to meet cost-effectiveness thresholds, in part because of high false-positive rates and the cost of ECG screening itself. The purpose of this study was to assess the testing characteristics of an automated ECG algorithm designed to screen for HCM in a multi-institutional pediatric cohort. ECGs from patients with HCM aged 12 to 20 years from 3 pediatric institutions were screened for ECG criteria for HCM using a previously described automated computer algorithm developed specifically for HCM ECG screening. The results were compared to a known healthy pediatric cohort. The studies then were read by trained electrophysiologists using standard ECG criteria and compared to the results of automated screening. One hundred twenty-eight ECGs from unique patients with phenotypic HCM were obtained and compared with 256 studies from healthy control patients matched in 2:1 fashion. When presented with the ECGs, the non-voltage-based algorithm resulted in 81.2% sensitivity and 90.7% specificity. A trained electrophysiologist read the same data according to the Seattle Criteria, with 71% sensitivity with 95.7% specificity. The sensitivity of screening as well as the components of the ECG screening itself varied by institution. This pilot study demonstrates a potential for automated ECG screening algorithms to detect HCM with testing characteristics similar to that of a trained electrophysiologist. In addition, there appear to be differences in ECG characteristics between patient populations, which may account for the difficulties in universal screening. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Zero risk tolerance costs lives: loss of transplantable organs due to human immunodeficiency virus nucleic acid testing of potential donors.

    PubMed

    Shafer, Teresa J; Schkade, David; Schkade, Lawrence; Geier, Steven S; Orlowski, Jeffrey P; Klintmalm, Goran

    2011-09-01

    Patients' deaths due to the organ donor shortage make it imperative that every suitable organ be transplanted. False-positive results of tests for infection with the human immunodeficiency virus (HIV) result in lost organs. A survey of US organ procurement organizations collected the numbers of donors and ruled-out potential donors who had a positive result on an HIV test from January 1,2006, to October 31, 2008. Sixty-two percent of US organ procurement organizations participated. Of the 12397 donor/nondonor cases, 56 (0.45%) had an initial positive result on an HIV antibody or HIV nucleic acid test, and only 8 (14.3%) of those were confirmed positive. Of the false-positive results, 50% were from HIV antibody tests and 50% were from HIV nucleic acid tests. Organs are a scarce, finite, and perishable resource. Use of HIV antibody testing has produced a remarkably safe track record of avoiding HIV transmission, with 22 years of nonoccurrence between transmissions. Because false positives occur with any test, including the HIV Ab test, adding nucleic acid testing to the standard donor testing panel doubles the number of false-positive HIV test results and thus the number of medically suitable donors lost. The required HIV antibody test is 99.99% effective in preventing transmission of the HIV virus. Adding the HIV nucleic acid test to routine organ donor screening could result in as many as 761 to 1551 unnecessary deaths of patients between HIV transmission events because medically suitable organs are wasted.

  18. Optoelectronic hit/miss transform for screening cervical smear slides

    NASA Astrophysics Data System (ADS)

    Narayanswamy, R.; Turner, R. M.; McKnight, D. J.; Johnson, K. M.; Sharpe, J. P.

    1995-06-01

    An optoelectronic morphological processor for detecting regions of interest (abnormal cells) on a cervical smear slide using the hit/miss transform is presented. Computer simulation of the algorithm tested on 184 Pap-smear images provided 95% detection and 5% false alarm. An optoelectronic implementation of the hit/miss transform is presented, along with preliminary experimental results.

  19. Expanding the scope of noninvasive prenatal testing: detection of fetal microdeletion syndromes.

    PubMed

    Wapner, Ronald J; Babiarz, Joshua E; Levy, Brynn; Stosic, Melissa; Zimmermann, Bernhard; Sigurjonsson, Styrmir; Wayham, Nicholas; Ryan, Allison; Banjevic, Milena; Lacroute, Phil; Hu, Jing; Hall, Megan P; Demko, Zachary; Siddiqui, Asim; Rabinowitz, Matthew; Gross, Susan J; Hill, Matthew; Benn, Peter

    2015-03-01

    The purpose of this study was to estimate the performance of a single-nucleotide polymorphism (SNP)-based noninvasive prenatal test for 5 microdeletion syndromes. Four hundred sixty-nine samples (358 plasma samples from pregnant women, 111 artificial plasma mixtures) were amplified with the use of a massively multiplexed polymerase chain reaction, sequenced, and analyzed with the use of the Next-generation Aneuploidy Test Using SNPs algorithm for the presence or absence of deletions of 22q11.2, 1p36, distal 5p, and the Prader-Willi/Angelman region. Detection rates were 97.8% for a 22q11.2 deletion (45/46) and 100% for Prader-Willi (15/15), Angelman (21/21), 1p36 deletion (1/1), and cri-du-chat syndromes (24/24). False-positive rates were 0.76% for 22q11.2 deletion syndrome (3/397) and 0.24% for cri-du-chat syndrome (1/419). No false positives occurred for Prader-Willi (0/428), Angelman (0/442), or 1p36 deletion syndromes (0/422). SNP-based noninvasive prenatal microdeletion screening is highly accurate. Because clinically relevant microdeletions and duplications occur in >1% of pregnancies, regardless of maternal age, noninvasive screening for the general pregnant population should be considered. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Analysis of 27 antibiotic residues in raw cow's milk and milk-based products--validation of Delvotest® T.

    PubMed

    Bion, Cindy; Beck Henzelin, Andrea; Qu, Yajuan; Pizzocri, Giuseppe; Bolzoni, Giuseppe; Buffoli, Elena

    2016-01-01

    Delvotest® T was evaluated for its capability at detecting residues of 27 antibiotics in raw cow's milk and in some dairy ingredients (skimmed and full-cream milk powders). The kit was used as a screening tool for the qualitative determination of antibiotics from different families in a single test. Results delivered by such a method are expressed as 'positive' or 'negative', referring to the claimed screening target concentration (STC). Validation was conducted according to the European Community Reference Laboratories' (CRLs) residues guidelines of 20 January 2010 and performed by two laboratories, one located in Europe and the other in Asia. Five criteria were evaluated including detection capability at STC, false-positive (FP) rate, false-negative (FN) rate, robustness and cross-reactivity using visual reading and Delvoscan®. STCs were set at or below the corresponding maximum residue limit (MRL), as fixed by European Regulation EC No. 37/2010. Four antibiotics (nafcillin, oxytetracycline, tetracycline and rifaximin) out of 27 had a false-negative rate ranging from 1.7% to 4.9%; however, it was still compliant with the CRLs' requirements. Globally, Delvotest T can be recommended for the analysis of the surveyed antibiotics in raw cow's milk, skimmed and full-cream milk powders. Additional compounds were tested such as sulfamethazine, spiramycin and erythromycin; however, detection at the corresponding MRL was not achievable and these compounds were removed from the validation. Other drugs from the sulfonamide, aminoglycoside or macrolide families not detected by the test at the MRL were not evaluated in this study. Regarding the reliability of this rapid test to milk-based preparations, additional experiments should be performed on a larger range of compounds and samples to validate the Delvotest T in such matrices.

  1. [Analysis of tools, methods and results of toxicological screening for detection of drug abuse in Italian professional drivers].

    PubMed

    Rosso, G L

    2013-01-01

    Three years after a protocol agreement between the State and the Regions came into force in 2008 (drug testing at the workplace Law) a large number of studies have been conducted to analyse and test the efficacy of on-site screening tests for detection of drug consumption (opiates, cocaine, cannabinoids, amphetamine and methamphetamine, MDMA and methadone), which are frequently used by the occupational health physician, and also to present data resulting from workplace drug testing obtained during health surveillance programmes. The aim of the present study was to verify whether the features of sensitivity and specificity of the most common on-site testing ensure correct application of the provisions of current Italian legislation and also to analyse published studies showing the frequency of positive drug testing. A review of Italian and international literature was carried out aimed at identifying studies relating to: (1) performance of on-site screening tests frequently used by the occupational health physician, (2) prevalence of drug use/abuse among Italian public and commercial transport drivers. A comparison between the studies was then carried out. Several rapid on-site screening tests are commercially available (Italian law does not provide standards for the technical specifications of the tests), the sensitivity and specificity of which varies depending on the model and the substance tested. The sensitivity of these tools is poor when used for the detection of low concentrations of drugs and/or their metabolites in urine (close to the cut-off). Studies are lacking that compare on-site tests performed by the occupational health physician and confirmative tests in specialized laboratories (with particular regard to false positives found by the occupational health physician). The major studies in terms of methods and/or size reported a positive rate (confirmed at the first level) between 1.6% and 1.9%. The drugs most frequently used/abused were cannabis and cocaine. The performance of on-site screening tests (to detect psychotropic substances on urine matrix) and the methodology required by Italian law show that the aims of Italian workplace drug testing legislation have not been achieved The low positive rate observed in Italian studies could be due to an error in the first phase of screening performed by the occupational health physician.

  2. Threshold magnitudes for a multichannel correlation detector in background seismicity

    DOE PAGES

    Carmichael, Joshua D.; Hartse, Hans

    2016-04-01

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  3. Validity of combined cytology and human papillomavirus (HPV) genotyping with adjuvant DNA-cytometry in routine cervical screening: results from 31031 women from the Bonn-region in West Germany.

    PubMed

    Bollmann, Reinhard; Bankfalvi, Agnes; Griefingholt, Harald; Trosic, Ante; Speich, Norbert; Schmitt, Christoph; Bollmann, Magdolna

    2005-05-01

    Our aim was to improve the accuracy of routine cervical screening by a risk-adapted multimodal protocol with special focus on possible reduction and prognostic assessment of false positive results. A cohort of 31031 women from the Bonn-region in West Germany, median age 36 years, were screened by cytology (conventional or liquid-based), followed by PCR-based HVP detection with genotyping and adjuvant DNA image cytometry, if indicated, in a sequential manner. The true prevalence of high-grade cervical intraepithelial neoplasia and carcinoma (>/=CIN2) was 0.32% in the population as projected from cervical biopsies of 123 women (0.4%), of whom 100 showed >/=CIN2. Sensitivity of the cytology screening program at PapIIID/HSIL threshold for detecting histologically confirmed >/=CIN2 cases was 81%, with specificity, positive predictive value (PPV) and negative predictive value (NPV) of 99, 20.9 and 99.9%, respectively. Of 38 women receiving the complete screening protocol, all the 31 >/=CIN2 cases were correctly detected by cytology alone, 30 by positive high-risk HPV genotype and 30 by aneuploid DNA profile. The combination of the three methods resulted in an up to 6.9% increase in PPV for >/=CIN2 at practically unchanged detection rate with the additional benefit of being able to predict the probable outcome of CIN1 lesions detected as false positives with any single test. Multimodal cervical screening might permit identification of those women with low-grade squamous intraepithelial lesions likely to progress at an earlier and curable stage of disease and lengthen the screening interval in those with transient minor lesions caused by productive HPV infection.

  4. Screening for Binge Eating Disorders Using the Patient Health Questionnaire in a Community Sample

    PubMed Central

    Striegel-Moore, Ruth H.; Perrin, Nancy; DeBar, Lynn; Wilson, G. Terence; Rosselli, Francine; Kraemer, Helena C.

    2009-01-01

    Objective To examine the operating characteristics of the Patient Health Questionnaire eating disorder module (PHQ-ED) for identifying bulimia nervosa/binge eating disorder (BN/BED) or recurrent binge eating (RBE) in a community sample, and to compare true positive (TP) versus false positive (FP) cases on clinical validators. Method 259 screen positive individuals and a random sample of 89 screen negative cases completed a diagnostic interview. Sensitivity, specificity, and Positive Predictive Value (PPV) were calculated. TP and FP cases were compared using t-tests and Chi-Square tests. Results The PHQ-ED had high sensitivity (100%) and specificity (92%) for detecting BN/BED or RBE, but PPV was low (15% or 19%). TP and FP cases did not differ significantly on frequency of subjective bulimic episodes, objective overeating, restraint, on BMI, and on self-rated health. Conclusions The PHQ-ED is recommended for use in large populations only in conjunction with follow-up questions to rule out cases without objective bulimic episodes. PMID:19424976

  5. Screening tests for the rapid detection of diarrhetic shellfish toxins in Washington State.

    PubMed

    Eberhart, Bich-Thuy L; Moore, Leslie K; Harrington, Neil; Adams, Nicolaus G; Borchert, Jerry; Trainer, Vera L

    2013-09-30

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test "pre-harvest" shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer's recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters.

  6. Screening Tests for the Rapid Detection of Diarrhetic Shellfish Toxins in Washington State

    PubMed Central

    Eberhart, Bich-Thuy L.; Moore, Leslie K.; Harrington, Neil; Adams, Nicolaus G.; Borchert, Jerry; Trainer, Vera L.

    2013-01-01

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test “pre-harvest” shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer’s recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters. PMID:24084788

  7. Cost implications of PSA screening differ by age.

    PubMed

    Rao, Karthik; Liang, Stella; Cardamone, Michael; Joshu, Corinne E; Marmen, Kyle; Bhavsar, Nrupen; Nelson, William G; Ballentine Carter, H; Albert, Michael C; Platz, Elizabeth A; Pollack, Craig E

    2018-05-09

    Multiple guidelines seek to alter rates of prostate-specific antigen (PSA)-based prostate cancer screening. The costs borne by payers associated with PSA-based screening for men of different age groups-including the costs of screening and subsequent diagnosis, treatment, and adverse events-remain uncertain. We sought to develop a model of PSA costs that could be used by payers and health care systems to inform cost considerations under a range of different scenarios. We determined the prevalence of PSA screening among men aged 50 and higher using 2013-2014 data from a large, multispecialty group, obtained reimbursed costs associated with screening, diagnosis, and treatment from a commercial health plan, and identified transition probabilities for biopsy, diagnosis, treatment, and complications from the literature to generate a cost model. We estimated annual total costs for groups of men ages 50-54, 55-69, and 70+ years, and varied annual prostate cancer screening prevalence in each group from 5 to 50% and tested hypothetical examples of different test characteristics (e.g., true/false positive rate). Under the baseline screening patterns, costs of the PSA screening represented 10.1% of the total costs; costs of biopsies and associated complications were 23.3% of total costs; and, although only 0.3% of all screen eligible patients were treated, they accounted for 66.7% of total costs. For each 5-percentage point decrease in PSA screening among men aged 70 and older for a single calendar year, total costs associated with prostate cancer screening decreased by 13.8%. For each 5-percentage point decrease in PSA screening among men 50-54 and 55-69 years old, costs were 2.3% and 7.3% lower respectively. With constrained financial resources and with national pressure to decrease use of clinically unnecessary PSA-based prostate cancer screening, there is an opportunity for cost savings, especially by focusing on the downstream costs disproportionately associated with screening men 70 and older.

  8. Validation and adaptation of the Norwegian version of Hayes Ability Screening Index for intellectual difficulties in a psychiatric sample.

    PubMed

    Søndenaa, Erik; Nygård, Øyvind; Nøttestad, Jim Aage; Linaker, Olav Martin

    2011-02-01

    Intellectual disabilities (ID) among psychiatric patients have traditionally been neglected. A lack of convenient instruments and competency in ID may have worsened the conditions and treatment availability for these patients. Validation and adaptation of a screening instrument for ID (Hayes Ability Screening Index; HASI) in a psychiatric hospital setting. This is a cross-sectional study of 50 psychiatric patients in two Norwegian psychiatric hospitals comparing results of the HASI with the Wechsler Abbreviated Scale of Intelligence (WASI). The HASI correlated well with the standard IQ test used (r= 0.67, P< 0.001). At a stated cut-off score of 85, the HASI had a sensitivity of 100% and specificity of 34%. The HASI is a valid and time-saving screening instrument for ID among psychiatric patients. The prescribed cut-off score, however, resulted in a large number of false positives.

  9. Cumulative False-Positive QuantiFERON-TB Interferon-γ Release Assay Results.

    PubMed

    Gamsky, Thomas E; Lum, Thomas; Hung-Fan, Melody; Green, Jon A

    2016-05-01

    Despite reports of unreliability, the QuantiFERON-TB interferon-γ release assay is increasingly used for the annual screening of individuals at risk for latent tuberculosis. Continued use of the QuantiFERON-TB assay suggests the need for more definitive evidence of its reproducibility and accuracy. To examine reproducibility and the accumulation of false-positive test results when the QuantiFERON-TB is repeated annually and to examine the validity of confirming positive test results with the performance of a second QuantiFERON-TB. We performed a retrospective, longitudinal evaluation of results from serial screening of a cohort of emergency responders from 2001 to 2013. Results of tuberculin tests and QuantiFERON-TB tests performed annually as part of a mandated first responder examination were retroactively reviewed. In this population, positive results occurred in new individuals each year. QuantiFERON-TB results were positive in 80 of 557 tuberculin test-negative individuals examined annually for a maximum of 7 years. Only 10 individuals with initially positive results remained positive when the test was repeated the next year, and 9 of these 10 were QuantiFERON-TB-negative within 3 years. The number of individuals with a positive result increased annually, and, after 7 years, 32 (27.4%) of 117 people had a positive result. When viewed in the context of the extensive literature documenting unreliable QuantiFERON-TB test performance, our findings of frequent, cumulative, sporadic, and irreproducible positive results support discontinuing the use of the QuantiFERON-TB assay for the diagnosis of latent tuberculosis in low-risk populations.

  10. Comparison of first-tier cell-free DNA screening for common aneuploidies with conventional publically funded screening.

    PubMed

    Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François

    2017-12-01

    This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.

  11. "It's a small price to pay for life": faecal occult blood test (FOBT) screening for colorectal cancer, perceived barriers and facilitators.

    PubMed

    Reeder, Anthony I

    2011-03-25

    To clarify perceptions influencing FOBT screening participation among the NZ European target population. Participants (30 female, 20 male; 50-71 years) recruited through urban (Auckland, Wellington, Christchurch) GP surgeries for in-depth, face-to-face interviews (digitally recorded and professionally transcribed verbatim). A pragmatic approach focused on aggregating transcript content. Participants believed early CRC lacked distinguishing signs and symptoms, but was treatable and suitable for screening, although slow development may undermine any sense of urgency. FOBT inaccuracies caused concern, particularly false negatives, but ongoing testing could reduce anxiety. Specimen collection was awkward, challenged social norms and individual squeamishness, but provided peace of mind, was painless, simple and private without high cost technological or professional involvement. Lacking preventive attitudes and experience of health responsibilities and screening, men were less likely to participate than women. CRC lacked public profile, highlighting government responsibility, before programme implementation, to resource high-profile education, largely through TV. General practitioner support and promotion was seen as critical. Inadequate health system capacity and resourcing was problematic. Despite challenging barriers, participants identified opportunities to increase FOBT screening participation, especially promotion to raise CRC profile, overcome perceived normative barriers and build self-efficacy. Adequate resourcing is essential to support appropriate promotion and timely programme delivery.

  12. Can missed breast cancer be recognized by regular peer auditing on screening mammography?

    PubMed

    Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai

    2012-09-01

    This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of < 0.05 was considered significant. Eight (6 traditional and 2 digital films) of the 176 false negative films were not reported by the auditors (missing rate of 4.5%). Of this total, 87 false negatives were reassessed as positive, while 29 of the 186 true negatives were reassessed as positive, making the overall performance of the 34 auditors in interpreting the false negatives and true negatives a specificity of 84.4% and sensitivity of 51.8%. The specificity and sensitivity in traditional films and laser-printed films were 98.6% versus 43.8% and 41.8% versus 78.3%, respectively. Almost 42% of the traditional false negative films had positive reassessment by the auditors, showing a significant difference from the initial screeners (p < 0.001). The specificity of their reinterpretation of laser-printed films was obviously low. Almost 42% of the false negative traditional films were judged as missed cancers in this study. A peer auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V

  13. Combinatorial support vector machines approach for virtual screening of selective multi-target serotonin reuptake inhibitors from large compound libraries.

    PubMed

    Shi, Z; Ma, X H; Qin, C; Jia, J; Jiang, Y Y; Tan, C Y; Chen, Y Z

    2012-02-01

    Selective multi-target serotonin reuptake inhibitors enhance antidepressant efficacy. Their discovery can be facilitated by multiple methods, including in silico ones. In this study, we developed and tested an in silico method, combinatorial support vector machines (COMBI-SVMs), for virtual screening (VS) multi-target serotonin reuptake inhibitors of seven target pairs (serotonin transporter paired with noradrenaline transporter, H(3) receptor, 5-HT(1A) receptor, 5-HT(1B) receptor, 5-HT(2C) receptor, melanocortin 4 receptor and neurokinin 1 receptor respectively) from large compound libraries. COMBI-SVMs trained with 917-1951 individual target inhibitors correctly identified 22-83.3% (majority >31.1%) of the 6-216 dual inhibitors collected from literature as independent testing sets. COMBI-SVMs showed moderate to good target selectivity in misclassifying as dual inhibitors 2.2-29.8% (majority <15.4%) of the individual target inhibitors of the same target pair and 0.58-7.1% of the other 6 targets outside the target pair. COMBI-SVMs showed low dual inhibitor false hit rates (0.006-0.056%, 0.042-0.21%, 0.2-4%) in screening 17 million PubChem compounds, 168,000 MDDR compounds, and 7-8181 MDDR compounds similar to the dual inhibitors. Compared with similarity searching, k-NN and PNN methods, COMBI-SVM produced comparable dual inhibitor yields, similar target selectivity, and lower false hit rate in screening 168,000 MDDR compounds. The annotated classes of many COMBI-SVMs identified MDDR virtual hits correlate with the reported effects of their predicted targets. COMBI-SVM is potentially useful for searching selective multi-target agents without explicit knowledge of these agents. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Effect of protocol-related variables and women's characteristics on the cumulative false-positive risk in breast cancer screening

    PubMed Central

    Román, R.; Sala, M.; Salas, D.; Ascunce, N.; Zubizarreta, R.; Castells, X.

    2012-01-01

    Background: Reducing the false-positive risk in breast cancer screening is important. We examined how the screening-protocol and women's characteristics affect the cumulative false-positive risk. Methods: This is a retrospective cohort study of 1 565 364 women aged 45–69 years who underwent 4 739 498 screening mammograms from 1990 to 2006. Multilevel discrete hazard models were used to estimate the cumulative false-positive risk over 10 sequential mammograms under different risk scenarios. Results: The factors affecting the false-positive risk for any procedure and for invasive procedures were double mammogram reading [odds ratio (OR) = 2.06 and 4.44, respectively], two mammographic views (OR = 0.77 and 1.56, respectively), digital mammography (OR = 0.83 for invasive procedures), premenopausal status (OR = 1.31 and 1.22, respectively), use of hormone replacement therapy (OR = 1.03 and 0.84, respectively), previous invasive procedures (OR = 1.52 and 2.00, respectively), and a familial history of breast cancer (OR = 1.18 and 1.21, respectively). The cumulative false-positive risk for women who started screening at age 50–51 was 20.39% [95% confidence interval (CI) 20.02–20.76], ranging from 51.43% to 7.47% in the highest and lowest risk profiles, respectively. The cumulative risk for invasive procedures was 1.76% (95% CI 1.66–1.87), ranging from 12.02% to 1.58%. Conclusions: The cumulative false-positive risk varied widely depending on the factors studied. These findings are relevant to provide women with accurate information and to improve the effectiveness of screening programs. PMID:21430183

  15. The inclusion of ADA-SCID in expanded newborn screening by tandem mass spectrometry.

    PubMed

    la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria Luisa; Canessa, Clementina; Lippi, Francesca; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara

    2014-01-01

    Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09μmol/L, adenosine <1.61μmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. 9 CFR 54.8 - Requirements for flock plans and post-exposure management and monitoring plans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Requirements for flock plans and post... and post-exposure management and monitoring plans. (a) The owner of the flock or his or her agent must...: Utilization of a live-animal screening test; restrictions on the animals that may be moved from the flock...

  17. 9 CFR 54.8 - Requirements for flock plans and post-exposure management and monitoring plans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Requirements for flock plans and post... and post-exposure management and monitoring plans. (a) The owner of the flock or his or her agent must...: Utilization of a live-animal screening test; restrictions on the animals that may be moved from the flock...

  18. 9 CFR 54.8 - Requirements for flock plans and post-exposure management and monitoring plans.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Requirements for flock plans and post... and post-exposure management and monitoring plans. (a) The owner of the flock or his or her agent must...: Utilization of a live-animal screening test; restrictions on the animals that may be moved from the flock...

  19. 9 CFR 54.8 - Requirements for flock plans and post-exposure management and monitoring plans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Requirements for flock plans and post... and post-exposure management and monitoring plans. (a) The owner of the flock or his or her agent must...: Utilization of a live-animal screening test; restrictions on the animals that may be moved from the flock...

  20. 9 CFR 54.8 - Requirements for flock plans and post-exposure management and monitoring plans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Requirements for flock plans and post... and post-exposure management and monitoring plans. (a) The owner of the flock or his or her agent must...: Utilization of a live-animal screening test; restrictions on the animals that may be moved from the flock...

  1. Identifying Novel Type ZBGs and Nonhydroxamate HDAC Inhibitors Through a SVM Based Virtual Screening Approach.

    PubMed

    Liu, X H; Song, H Y; Zhang, J X; Han, B C; Wei, X N; Ma, X H; Cui, W K; Chen, Y Z

    2010-05-17

    Histone deacetylase inhibitors (HDACi) have been successfully used for the treatment of cancers and other diseases. Search for novel type ZBGs and development of non-hydroxamate HDACi has become a focus in current research. To complement this, it is desirable to explore a virtual screening (VS) tool capable of identifying different types of potential inhibitors from large compound libraries with high yields and low false-hit rates similar to HTS. This work explored the use of support vector machines (SVM) combined with our newly developed putative non-inhibitor generation method as such a tool. SVM trained by 702 pre-2008 hydroxamate HDACi and 64334 putative non-HDACi showed good yields and low false-hit rates in cross-validation test and independent test using 220 diverse types of HDACi reported since 2008. The SVM hit rates in scanning 13.56 M PubChem and 168K MDDR compounds are comparable to HTS rates. Further structural analysis of SVM virtual hits suggests its potential for identification of non-hydroxamate HDACi. From this analysis, a series of novel ZBG and cap groups were proposed for HDACi design. Copyright © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A false positive newborn screening result due to a complex allele carrying two frequent CF-causing variants.

    PubMed

    Bergougnoux, Anne; Boureau-Wirth, Amandine; Rouzier, Cécile; Altieri, Jean-Pierre; Verneau, Fanny; Larrieu, Lise; Koenig, Michel; Claustres, Mireille; Raynal, Caroline

    2016-05-01

    The detection of two frequent CFTR disease-causing variations in the context of a newborn screening program (NBS) usually leads to the diagnosis of cystic fibrosis (CF) and a relevant genetic counseling in the family. In the present study, CF-causing variants p.Phe508del (F508del) and c.3140-26A>G (3272-26A>G) were identified on a neonate with positive ImmunoReactive Trypsinogen test by the Elucigene™ CF30 kit. The CF diagnosis initially suggested, despite three inconclusive Sweat Chloride Tests (SCT), was finally ruled out after the familial segregation study combined with a negative SCT. Haplotype studies, based on the comparison of 80 p.Phe508del haplotypes, suggested a probable de novo occurrence of c.3140-26A>G on the p.Phe508del ancestral allele in this family. This false positive case emphasizes the importance of SCT in the NBS strategy. Moreover, it raises the need for familial segregation studies in CF and in overall molecular diagnosis strategy of autosomal recessive diseases. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  3. Interferences on microbial inhibitor tests related to ivermectin treatment in lactating dairy goats.

    PubMed

    Romero, Tamara; Moya, Vicente Javier; Fernández, Nemesio; Althaus, Rafael; Reybroeck, Wim; Molina, María Pilar

    2016-08-01

    This Research Communication reports interferences related to the administration of ivermectin in lactating dairy goats on the response of microbial tests for screening antibiotics in milk. Twenty-eight Murciano-Granadina goats, naturally infested with Sarcoptes scabiei var. caprae, were treated with a subcutaneous injection of ivermectin (200 µg/kg b.w.). To prevent re-infestation, a second dose was applied 7 d later. Individual milk samples were collected, daily, up to 15 d post-treatment. Milk samples were analysed by microbial inhibitor tests (BRT MRL, Delvotest SP-NT MCS and Eclipse 100) and ivermectin residues were quantified by HPLC. A large number of positive results were obtained for all microbial tests, especially on the first day after treatment (BRT MRL = 46·4%; Delvotest SP-NT MCS = 14·3%; and Eclipse 100 = 17·8%). However, the highest concentration of drug residues in milk (24·3 ng/ml) was detected on the tenth day after treatment, when positive outcomes were relatively lower (BRT MRL = 17·8%; Delvotest SP-NT MCS = 10·7%; and Eclipse 100 = 7·4%). Results herein suggest that factors related to the ivermectin treatment other than drug residues in milk, or alterations produced by the parasitic disease itself affecting the immune response of animals, could be the cause of false-positive results in microbial tests. It can be concluded that the application of ivermectin in dairy goats infested with sarcoptes mange during lactation produces persistent drug residues in milk, and could also cause false-positive results in microbial inhibitor tests for screening antibiotics.

  4. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    PubMed

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Periodic Screening Pelvic Examination: Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Guirguis-Blake, Janelle M; Henderson, Jillian T; Perdue, Leslie A

    2017-03-07

    Recent changes in the periodicity of cervical cancer screening have led to questions about the role of screening pelvic examinations among asymptomatic women. To systematically review literature on health benefits, accuracy, and harms of the screening pelvic examination for gynecologic conditions for the US Preventive Services Task Force (USPSTF). MEDLINE, PubMed, and Cochrane Central Register of Controlled Trials for relevant English-language studies published through January 13, 2016, with surveillance through August 3, 2016. Two reviewers independently screened abstracts and studies. The search yielded 8678 unique citations; 316 full-text articles were reviewed, and 9 studies including 27 630 patients met inclusion criteria. Two reviewers rated study quality using USPSTF criteria. Morbidity; mortality; diagnostic accuracy for any gynecologic cancer or condition except cervical cancer, gonorrhea, and chlamydia, which are covered by other USPSTF screening recommendations; harms (false-positive rates, false-negative rates, surgery rates). No trials examined the effectiveness of the pelvic examination in reducing all-cause mortality, reducing cancer- and disease-specific morbidity and mortality, or improving quality of life. Eight studies reported accuracy for the screening pelvic examination: ovarian cancer (4 studies; n = 26 432), bacterial vaginosis (2 studies; n = 930), trichomoniasis (1 study; n = 779), and genital herpes (1 study; n = 779). In the 4 ovarian cancer screening studies, low prevalence of ovarian cancer consistently resulted in low positive predictive values (PPVs) and false-positive rates, with a lack of precision in accuracy estimates (sensitivity range, 0%-100%; specificity range, 91%-99%; PPV range, 0%-3.6%; negative predictive value [NPV] range, ≥99%). Each diagnostic accuracy study for bacterial vaginosis, trichomoniasis, and genital herpes was performed in a high-prevalence population with substantial proportions of symptomatic patients and reported accuracy characteristics for individual physical examination findings (bacterial vaginosis, homogeneous discharge: sensitivity range, 69%-79%; specificity range, 54%-97%; PPV range, 52%-95%; NPV range, 79%-80%; herpes simplex virus, vulvar ulcerations: sensitivity, 20%; specificity, 98%; PPV, 88%; NPV, 57%; trichomoniasis, colpitis macularis: sensitivity, 2%; specificity, 100%; PPV, 100%; NPV, 85%). Surgery rates resulting from an abnormal screening pelvic examination for ovarian cancer ranged from 5% to 36% at 1 year, with the largest study reporting an 11% surgery rate and 1% complication rate within 1 year of a screening pelvic examination with abnormal findings. No direct evidence was identified for overall benefits and harms of the pelvic examination as a 1-time or periodic screening test. Limited evidence was identified regarding the diagnostic accuracy and harms of routine screening pelvic examinations in asymptomatic primary care populations.

  6. Screening for Prostate Cancer: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Grossman, David C; Curry, Susan J; Owens, Douglas K; Bibbins-Domingo, Kirsten; Caughey, Aaron B; Davidson, Karina W; Doubeni, Chyke A; Ebell, Mark; Epling, John W; Kemper, Alex R; Krist, Alex H; Kubik, Martha; Landefeld, C Seth; Mangione, Carol M; Silverstein, Michael; Simon, Melissa A; Siu, Albert L; Tseng, Chien-Wen

    2018-05-08

    In the United States, the lifetime risk of being diagnosed with prostate cancer is approximately 13%, and the lifetime risk of dying of prostate cancer is 2.5%. The median age of death from prostate cancer is 80 years. Many men with prostate cancer never experience symptoms and, without screening, would never know they have the disease. African American men and men with a family history of prostate cancer have an increased risk of prostate cancer compared with other men. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on prostate-specific antigen (PSA)-based screening for prostate cancer. The USPSTF reviewed the evidence on the benefits and harms of PSA-based screening for prostate cancer and subsequent treatment of screen-detected prostate cancer. The USPSTF also commissioned a review of existing decision analysis models and the overdiagnosis rate of PSA-based screening. The reviews also examined the benefits and harms of PSA-based screening in patient subpopulations at higher risk of prostate cancer, including older men, African American men, and men with a family history of prostate cancer. Adequate evidence from randomized clinical trials shows that PSA-based screening programs in men aged 55 to 69 years may prevent approximately 1.3 deaths from prostate cancer over approximately 13 years per 1000 men screened. Screening programs may also prevent approximately 3 cases of metastatic prostate cancer per 1000 men screened. Potential harms of screening include frequent false-positive results and psychological harms. Harms of prostate cancer treatment include erectile dysfunction, urinary incontinence, and bowel symptoms. About 1 in 5 men who undergo radical prostatectomy develop long-term urinary incontinence, and 2 in 3 men will experience long-term erectile dysfunction. Adequate evidence shows that the harms of screening in men older than 70 years are at least moderate and greater than in younger men because of increased risk of false-positive results, diagnostic harms from biopsies, and harms from treatment. The USPSTF concludes with moderate certainty that the net benefit of PSA-based screening for prostate cancer in men aged 55 to 69 years is small for some men. How each man weighs specific benefits and harms will determine whether the overall net benefit is small. The USPSTF concludes with moderate certainty that the potential benefits of PSA-based screening for prostate cancer in men 70 years and older do not outweigh the expected harms. For men aged 55 to 69 years, the decision to undergo periodic PSA-based screening for prostate cancer should be an individual one and should include discussion of the potential benefits and harms of screening with their clinician. Screening offers a small potential benefit of reducing the chance of death from prostate cancer in some men. However, many men will experience potential harms of screening, including false-positive results that require additional testing and possible prostate biopsy; overdiagnosis and overtreatment; and treatment complications, such as incontinence and erectile dysfunction. In determining whether this service is appropriate in individual cases, patients and clinicians should consider the balance of benefits and harms on the basis of family history, race/ethnicity, comorbid medical conditions, patient values about the benefits and harms of screening and treatment-specific outcomes, and other health needs. Clinicians should not screen men who do not express a preference for screening. (C recommendation) The USPSTF recommends against PSA-based screening for prostate cancer in men 70 years and older. (D recommendation).

  7. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    PubMed

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  8. Buprenorphine detection in hair samples by immunometric screening test: preliminary experience.

    PubMed

    Svaizer, Fiorenza; Lotti, Andrea; Gottardi, Massimo; Miozzo, Maria Pia

    2010-03-20

    The recent introduction of buprenorphine use by the Drug Addiction Services has induced toxicology laboratories to develop new qualitative or semiquantitative screening assay for its determination in hair samples. The aim of this preliminary study was to verify the correlation between the buprenorphine intake and the immunometric screening test results (VMA-T Comedical and buprenorphine CEDIA/Thermo-Fisher/Microgenics reagents) and therefore their comparison with the liquid chromatography coupled with mass spectrometry (LC/MS) results. Hair samples were obtained from 32 subjects without buprenorphine-therapy reported and 17 in treatment. In glass test tube with hermetic cap were weighed 33 mg of 49 finely cut hair samples, washed with 1 mL of SLV-VMA-T washing solution, which is then completely sucked and eliminated. The samples were extracted with 400 microL of VMA-T reagent for an hour at 100 degrees C. The extracts were analysed by immunometric screening test on ILab 650 chemistry analyser, using buprenorphine CEDIA reagent assay. From the 32 non-takers of drug, 30 semiquantitative results were less than 10 pg/mg and 2 were over 10 pg/mg; from the 17 subjects with therapy, all were over 10 pg/mg (range 13-50 pg/mg); no samples were false-negative. Results suggest that exist a good relationship between the administration of buprenorphine and its concentration in hair, detectable through this method and reagents line. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Handheld echocardiographic screening for rheumatic heart disease by non-experts.

    PubMed

    Ploutz, Michelle; Lu, Jimmy C; Scheel, Janet; Webb, Catherine; Ensing, Greg J; Aliku, Twalib; Lwabi, Peter; Sable, Craig; Beaton, Andrea

    2016-01-01

    Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening. Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified. A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11). Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Breast Cancer Risk Prediction and Mammography Biopsy Decisions

    PubMed Central

    Armstrong, Katrina; Handorf, Elizabeth A.; Chen, Jinbo; Demeter, Mirar N. Bristol

    2012-01-01

    Background Controversy continues about screening mammography, in part because of the risk of false-negative and false-positive mammograms. Pre-test breast cancer risk factors may improve the positive and negative predictive value of screening. Purpose To create a model that estimates the potential impact of pre-test risk prediction using clinical and genomic information on the reclassification of women with abnormal mammograms (BI-RADS3 and BI-RADS4 [Breast Imaging-Reporting and Data System]) above and below the threshold for breast biopsy. Methods The current study modeled 1-year breast cancer risk in women with abnormal screening mammograms using existing data on breast cancer risk factors, 12 validated breast cancer single nucleotide polymorphisms (SNPs), and probability of cancer given the BI-RADS category. Examination was made of reclassification of women above and below biopsy thresholds of 1%, 2%, and 3% risk. The Breast Cancer Surveillance Consortium data were collected from 1996 to 2002. Data analysis was conducted in 2010 and 2011. Results Using a biopsy risk threshold of 2% and the standard risk factor model, 5% of women with a BI-RADS3 mammogram had a risk above the threshold, and 3% of women with BIRADS4A mammograms had a risk below the threshold. The addition of 12 SNPs in the model resulted in 8% of women with a BI-RADS3 mammogram above the threshold for biopsy and 7% of women with BI-RADS4A mammograms below the threshold. Conclusions The incorporation of pre-test breast cancer risk factors could change biopsy decisions for a small proportion of women with abnormal mammograms. The greatest impact comes from standard breast cancer risk factors. PMID:23253645

  11. Strongyloides hyperinfection following hematopoietic stem cell transplant in a patient with HTLV-1-associated T-cell leukemia.

    PubMed

    Alpern, Jonathan D; Arbefeville, Sophie S; Vercellotti, Gregory; Ferrieri, Patricia; Green, Jaime S

    2017-02-01

    Strongyloides stercoralis has the potential to cause accelerated autoinfection in immunocompromised hosts. Screening tests for strongyloidiasis may be falsely negative in the setting of immunosuppression. We report a case of Strongyloides hyperinfection syndrome in a patient with human T-lymphotropic virus type 1-associated T-cell leukemia early after hematopoietic stem cell transplant. The diagnosis was made by stool ova and parasite examination, despite a negative screening enzyme-linked immunosorbent assay. Because of anticipated prolonged neutropenia, an extended course of treatment was utilized. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A novel gamma-fitting statistical method for anti-drug antibody assays to establish assay cut points for data with non-normal distribution.

    PubMed

    Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena

    2010-01-31

    In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.

  13. Methods Used in Economic Evaluations of Chronic Kidney Disease Testing — A Systematic Review

    PubMed Central

    Sutton, Andrew J.; Breheny, Katie; Deeks, Jon; Khunti, Kamlesh; Sharpe, Claire; Ottridge, Ryan S.; Stevens, Paul E.; Cockwell, Paul; Kalra, Philp A.; Lamb, Edmund J.

    2015-01-01

    Background The prevalence of chronic kidney disease (CKD) is high in general populations around the world. Targeted testing and screening for CKD are often conducted to help identify individuals that may benefit from treatment to ameliorate or prevent their disease progression. Aims This systematic review examines the methods used in economic evaluations of testing and screening in CKD, with a particular focus on whether test accuracy has been considered, and how analysis has incorporated issues that may be important to the patient, such as the impact of testing on quality of life and the costs they incur. Methods Articles that described model-based economic evaluations of patient testing interventions focused on CKD were identified through the searching of electronic databases and the hand searching of the bibliographies of the included studies. Results The initial electronic searches identified 2,671 papers of which 21 were included in the final review. Eighteen studies focused on proteinuria, three evaluated glomerular filtration rate testing and one included both tests. The full impact of inaccurate test results was frequently not considered in economic evaluations in this setting as a societal perspective was rarely adopted. The impact of false positive tests on patients in terms of the costs incurred in re-attending for repeat testing, and the anxiety associated with a positive test was almost always overlooked. In one study where the impact of a false positive test on patient quality of life was examined in sensitivity analysis, it had a significant impact on the conclusions drawn from the model. Conclusion Future economic evaluations of kidney function testing should examine testing and monitoring pathways from the perspective of patients, to ensure that issues that are important to patients, such as the possibility of inaccurate test results, are properly considered in the analysis. PMID:26465773

  14. A Structured Implicit Abstraction Method to Evaluate whether Content of Counseling before Prostate Cancer Screening is Consistent with Recommendations by Experts

    PubMed Central

    Farrell, Michael H.; Chan, Evelyn C.Y.; Ladouceur, Lynnea K.; Stein, Jeffrey M.

    2009-01-01

    Objective To assess the content of counseling about prostate-specific antigen (PSA) screening. Guidelines recommend informed consent before screening because of concerns about benefits versus risks. As part of the professional practice standard for informed consent, clinicians should include content customarily provided by experts. Methods 40 transcripts of conversations between medicine residents and standardized patients were abstracted using an instrument derived from an expert Delphi panel that ranked 10 “facts that experts believe men ought to know.” Results Transcripts contained definite criteria for an average of 1.7 facts, and either definite or partial criteria for 5.1 facts. Second- and third-year residents presented more facts than interns (p=0.01). The most common facts were “false positive PSA tests can occur” and “use of the PSA test as a screening test is controversial.” There was an r=0.88 correlation between inclusion by residents and the experts’ ranking. Conclusion Counseling varied but most transcripts included some expert-recommended facts. The absence of other facts could be a quality deficit or an effort to prioritize messages and lessen cognitive demands on the patient. Practice implications Clinicians should adapt counseling for each patient, but our abstraction approach may help to assess the quality of informed consent over larger populations. PMID:19837527

  15. Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.

    PubMed

    Iskandar, Livia; Braun, Kathryn L; Katz, Alan R

    2015-04-01

    Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.

  16. Lessons learned from the use of HRP-2 based rapid diagnostic test in community-wide screening and treatment of asymptomatic carriers of Plasmodium falciparum in Burkina Faso.

    PubMed

    Tiono, Alfred B; Ouédraogo, Alphonse; Diarra, Amidou; Coulibaly, Sam; Soulama, Issiaka; Konaté, Amadou T; Barry, Aïssata; Mukhopadhyay, Amitava; Sirima, Sodiomon B; Hamed, Kamal

    2014-01-27

    Rapid diagnostic tests (RDTs) are immune chromatographic tests targeting antigens of one or more Plasmodium species and offer the potential to extend accurate malaria diagnosis in endemic areas. In this study, the performance of Plasmodium falciparum-specific histidine-rich protein-2 (PfHRP-2) RDT in the detection of asymptomatic carriers from a hyperendemic region of Burkina Faso was compared with microscopy to gain further insight on its relevance in community-based interventions. The performance of HRP-2 test was evaluated in terms of sensitivity, specificity, positive and negative predictive values, discordant values, likelihood ratios, accuracy, and precision using microscopy as the 'gold standard'. This analysis was carried out in a controlled, parallel, cluster-randomized (18 clusters; 1:1) study in children and adults. The effect of systematic treatment of P. falciparum asymptomatic carriers during three consecutive monthly community screening campaigns on the incidence of symptomatic malaria episodes over a 12-month period was compared with no treatment of asymptomatic carriers. Sensitivity of HRP-2 test in asymptomatic carriers was higher in campaign 1 (92.4%) when compared to campaign 2 (84.0%) and campaign 3 (77.8%). The sensitivity of HRP-2 test increased as parasite density increased across all the age groups. Highest sensitivity (≥97.0%) was recorded at parasite densities of 1,000-4,999/μl, except for children aged 10 to 14 years. The specificity of HRP-2 test was comparable across age groups and highest in campaign 3 (95.9%). The negative predictive values were high across the three campaigns (≥92.7%) while the positive predictive values ranged from 23.2 to 73.8%. False-positive and false-negative rates were high in campaign 1 and campaign 3, respectively. The performance of HRP-2 test in detecting asymptomatic carriers of P. falciparum varied by age and parasite density. Although the use of HRP-2 test is beneficial for the diagnosis of acute malaria, its low sensitivity in screening asymptomatic carriers may limit its utility in pre-elimination interventional settings. The use of a practical and more sensitive test such as loop-mediated isothermal amplification in combination with a cost effective HRP-2 test may be worth exploring in such settings.

  17. Evaluation of health benefits and harms of the breast cancer screening programme in the Basque Country using discrete event simulation.

    PubMed

    Arrospide, Arantzazu; Rue, Montserrat; van Ravesteyn, Nicolien T; Comas, Merce; Larrañaga, Nerea; Sarriugarte, Garbiñe; Mar, Javier

    2015-10-12

    Since the breast cancer screening programme in the Basque Country (BCSPBC) was started in 1996, more than 400,000 women aged 50 to 69 years have been invited to participate. Based on epidemiological observations and simulation techniques it is possible to extend observed short term data into anticipated long term results. The aim of this study was to assess the effectiveness of the programme through 2011 by quantifying the outcomes in breast cancer mortality, life-years gained, false positive results, and overdiagnosis. A discrete event simulation model was constructed to reproduce the natural history of breast cancer (disease-free, pre-clinical, symptomatic, and disease-specific death) and the actual observed characteristics of the screening programme during the evaluated period in the Basque women population. Goodness-of-fit statistics were applied for model validation. The screening effects were measured as differences in benefits and harms between the screened and unscreened populations. Breast cancer mortality reduction and life-years gained were considered as screening benefits, whereas, overdiagnosis and false positive results were assessed as harms. Results for a single cohort were also obtained. The screening programme yielded a 16 % reduction in breast cancer mortality and a 10 % increase in the incidence of breast cancer through 2011. Almost 2 % of all the women in the programme had a false positive result during the evaluation period. When a single cohort was analysed, the number of deaths decreased by 13 %, and 4 % of screen-detected cancers were overdiagnosed. Each woman with BC detected by the screening programme gained 2.5 life years due to early detection corrected by lead time. Fifteen years after the screening programme started, this study supports an important decrease in breast cancer mortality due to the screening programme, with reasonable risk of overdiagnosis and false positive results, and sustains the continuation of the breast cancer screening programme in the Basque population.

  18. Validation of a hospital-laboratory workstation for immunohematologic methods.

    PubMed

    Schoenfeld, Helge; Pretzel, Karin J; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel

    2010-01-01

    The FREELYS Nano system (Diagast) is a manual workstation for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS) for immunoglobulin G (IgG) antibodies only and works with the erythrocyte-magnetized technology (EMT). The principle of EMT is based on magnetization of red blood cells and avoids centrifugation and washing steps. A total of 304 samples were tested with our routine blood bank methods, 100 samples for ABO/D grouping, 196 samples (100 at first evaluation, 96 at second evaluation) for Rh phenotyping and K typing (PK7200, Olympus), and 108 samples for ABS (DiaMed). All samples were tested in parallel with the FREELYS Nano. We found a 100% concordance between the observed (FREELYS Nano) and the expected (Olympus PK7200) results for ABO/D grouping in all 100 samples. For Rh phenotyping and K tests, in 24 of 100 samples false-positive reactions were observed in the first evaluation by the FREELYS Nano. After changing the test kit batch for Rh phenotyping by the manufacturer, a complete concordance in Rh phenotyping and K tests was observed in a second evaluation. For ABS, the FREELYS Nano showed in 4 of 108 samples (3.7%) false-negative reactions for IgG antibodies (two anti-K, one anti-E, one anti-C(w)), and one (0.9%) false-positive reaction. The FREELYS Nano is reliably suited to ABO/D grouping, Rh phenotyping, and K testing. The rate of false-negative reactions for IgG antibodies should be reduced.

  19. Dipstick screening for urinary tract infection in febrile infants.

    PubMed

    Glissmeyer, Eric W; Korgenski, E Kent; Wilkes, Jacob; Schunk, Jeff E; Sheng, Xiaoming; Blaschke, Anne J; Byington, Carrie L

    2014-05-01

    This study compares the performance of urine dipstick alone with urine microscopy and with both tests combined as a screen for urinary tract infection (UTI) in febrile infants aged 1 to 90 days. We queried the Intermountain Healthcare data warehouse to identify febrile infants with urine dipstick, microscopy, and culture performed between 2004 and 2011. UTI was defined as >50 000 colony-forming units per milliliter of a urinary pathogen. We compared the performance of urine dipstick with unstained microscopy or both tests combined ("combined urinalysis") to identify UTI in infants aged 1 to 90 days. Of 13 030 febrile infants identified, 6394 (49%) had all tests performed and were included in the analysis. Of these, 770 (12%) had UTI. Urine culture results were positive within 24 hours in 83% of UTIs. The negative predictive value (NPV) was >98% for all tests. The combined urinalysis NPV was 99.2% (95% confidence interval: 99.1%-99.3%) and was significantly greater than the dipstick NPV of 98.7% (98.6%-98.8%). The dipstick positive predictive value was significantly greater than combined urinalysis (66.8% [66.2%-67.4%] vs 51.2% [50.6%-51.8%]). These data suggest 8 febrile infants would be predicted to have a false-positive combined urinalysis for every 1 infant with UTI initially missed by dipstick screening. Urine dipstick testing compares favorably with both microscopy and combined urinalysis in febrile infants aged 1 to 90 days. The urine dipstick test may be an adequate stand-alone screen for UTI in febrile infants while awaiting urine culture results. Copyright © 2014 by the American Academy of Pediatrics.

  20. Identification of early HIV infections using the fourth generation Abbott ARCHITECT HIV Ag/Ab Combo chemiluminescent microparticle immunoassay (CIA) in San Diego County.

    PubMed

    Manlutac, Anna Liza M; Giesick, Jill S; McVay, Patricia A

    2013-12-01

    HIV screening assays have gone through several generations of development in an effort to narrow the "window period" of detection. Utilizing a fourth generation HIV screening assay has the potential to detect earlier HIV infection, thus reducing HIV-1 transmission. To identify acute infections to decrease HIV transmission in San Diego County. Serum specimens were collected from clients seen by multiple submitters in San Diego County. All acceptable specimens were screened using the 4th Gen Combo Assay. Initially reactive specimens were repeated in duplicate and if repeatedly reactive, were confirmed by HIV-1 Immunofluorescent Antibody Assay (IFA). IFA negative/inconclusive specimens were sent for HIV-1 NAT and HIV-2 antibody testing to referral laboratories. BioRad Multispot HIV-1/HIV-2 Rapid Test was also performed on a subset of specimens. Of 14,559 specimens received in 20 months, 14,517 specimens were tested. Of the 14,517 specimens that were tested, a total of 279 (1.9%) specimens were CIA repeatedly reactive and 240 of the 279 confirmed by HIV-1 IFA. Thirty-nine gave IFA negative/inconclusive result and 30 were further tested for HIV-1 NAT and 36 for HIV-2 antibody. Thirteen specimens were considered false positives by CIA and 17 specimens were classified as acute infections. Eleven of 39 IFA negative/inconclusive specimens were further tested by Multispot. Five of the 11 were positive by Multispot. The fourth generation Abbott ARCHITECT HIV Ag/Ab Combo Assay identified 17 patients who may have been missed by the prior HIV-1 screening assay used at San Diego County Public Health Laboratory. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Genome-wide association screens for Achilles tendon and ACL tears and tendinopathy

    PubMed Central

    Roos, Thomas R.; Roos, Andrew K.; Kleimeyer, John P.; Ahmed, Marwa A.; Goodlin, Gabrielle T.; Fredericson, Michael; Ioannidis, John P. A.; Avins, Andrew L.; Dragoo, Jason L.

    2017-01-01

    Achilles tendinopathy or rupture and anterior cruciate ligament (ACL) rupture are substantial injuries affecting athletes, associated with delayed recovery or inability to return to competition. To identify genetic markers that might be used to predict risk for these injuries, we performed genome-wide association screens for these injuries using data from the Genetic Epidemiology Research on Adult Health and Aging (GERA) cohort consisting of 102,979 individuals. We did not find any single nucleotide polymorphisms (SNPs) associated with either of these injuries with a p-value that was genome-wide significant (p<5x10-8). We found, however, four and three polymorphisms with p-values that were borderline significant (p<10−6) for Achilles tendon injury and ACL rupture, respectively. We then tested SNPs previously reported to be associated with either Achilles tendon injury or ACL rupture. None showed an association in our cohort with a false discovery rate of less than 5%. We obtained, however, moderate to weak evidence for replication in one case; specifically, rs4919510 in MIR608 had a p-value of 5.1x10-3 for association with Achilles tendon injury, corresponding to a 7% chance of false replication. Finally, we tested 2855 SNPs in 90 candidate genes for musculoskeletal injury, but did not find any that showed a significant association below a false discovery rate of 5%. We provide data containing summary statistics for the entire genome, which will be useful for future genetic studies on these injuries. PMID:28358823

  2. HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia.

    PubMed

    Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo

    2018-04-17

    Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  3. Beyond Critical Congenital Heart Disease: Newborn Screening Using Pulse Oximetry for Neonatal Sepsis and Respiratory Diseases in a Middle-Income Country.

    PubMed

    Jawin, Vida; Ang, Hak-Lee; Omar, Asma; Thong, Meow-Keong

    2015-01-01

    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country. In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively. Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low- and middle-income countries contemplating strategies to reduce neonatal mortality and morbidity. ASD, atrial septal defect; CCHD, critical congenital heart disease; CRP, C-reactive protein; CXR, chest radiographs; NDI, neurodevelopment impairment; PPHN, persistent pulmonary hypertension of the newborn; PDA, patent ductus arteriosus; PFO, patent foramen ovale; TGA, transposition of great artery; TTN, transient tachypnoea of the newborn; VSD, ventricular septal defect.

  4. Screening for sexually transmitted infection pathogens in semen samples

    PubMed Central

    Peeling, RW; Embree, J

    2005-01-01

    The transmission of sexually transmitted infection (STI) pathogens from an infected donor to the recipient of a semen donation in assisted conception may result not only in acute infection but also in long-term reproductive complications or adverse outcomes of pregnancy, including infection of the offspring. Screening for bacterial STI pathogens, Chlamydia trachomatis and Neisseria gonorrhoeae is strongly recommended because these pathogens can cause serious reproductive complications in the recipients of semen donations and infection in their offspring. Screening for these pathogens should be performed using the most sensitive methods, such as nucleic acid amplified tests. False-negative results due to inhibitory substances in the semen sample should be monitored using amplification controls. Where specimen transport is not a problem and culture facilities are available, N gonorrhoeae can also be detected by culture. Laboratories performing screening should subscribe to proficiency programs and have strict quality controls. Although Trichomonas vaginalis, group B streptococcus and genital mycoplasmas have been associated with adverse outcomes of pregnancy, the frequent finding of these organisms in healthy individuals brings into question the validity of mandatory inclusion of these organisms in the screening panel. Although viral STI pathogens and Treponema pallidum - the causative agent of syphilis - may be detected in semen, their presence may be more sensitively detected through antibody testing of the donor. Screening donors for HIV, hepatitis B and syphilis by serology is uniformly recommended in all of the guidelines, but the value of screening either donors or semen samples for cytomegalovirus, herpes simplex viruses and human papilloma viruses is less clear. PMID:18159531

  5. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    NASA Astrophysics Data System (ADS)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  6. Cumulative risk of breast cancer screening outcomes according to the presence of previous benign breast disease and family history of breast cancer: supporting personalised screening.

    PubMed

    Román, M; Quintana, M J; Ferrer, J; Sala, M; Castells, X

    2017-05-23

    Our aim was to assess the cumulative risk of false-positive screening results, screen-detected cancer, and interval breast cancer in mammography screening among women with and without a previous benign breast disease and a family history of breast cancer. The cohort included 42 928 women first screened at the age of 50-51 years at three areas of the Spanish Screening Programme (Girona, and two areas in Barcelona) between 1996 and 2011, and followed up until December 2012. We used discrete-time survival models to estimate the cumulative risk of each screening outcome over 10 biennial screening exams. The cumulative risk of false-positive results, screen-detected breast cancer, and interval cancer was 36.6, 5.3, and 1.4 for women with a previous benign breast disease, 24.1, 6.8, and 1.6% for women with a family history of breast cancer, 37.9, 9.0, and 3.2%; for women with both a previous benign breast disease and a family history, and 23.1, 3.2, and 0.9% for women without either of these antecedents, respectively. Women with a benign breast disease or a family history of breast cancer had an increased cumulative risk of favourable and unfavourable screening outcomes than women without these characteristics. A family history of breast cancer did not increase the cumulative risk of false-positive results. Identifying different risk profiles among screening participants provides useful information to stratify women according to their individualised risk when personalised screening strategies are discussed.

  7. Towards personalized screening: cumulative risk of breast cancer screening outcomes in women with and without a first-degree relative with a history of breast cancer

    PubMed Central

    Ripping, T.M.; Hubbard, R.A.; Otten, J.D.M.; den Heeten, G.J.; Verbeek, A.L.M.; Broeders, M.J.M.

    2016-01-01

    Several reviews have estimated the balance of benefits and harms of mammographic screening in the general population. The balance may, however, differ between individuals with and without family history. Therefore, our aim is to assess the cumulative risk of screening outcomes; screen-detected breast cancer, interval cancer, and false-positive results, in women screenees aged 50–75 and 40–75, with and without a first-degree relative with a history of breast cancer at the start of screening. Data on screening attendance, recall and breast cancer detection were collected for each woman living in Nijmegen (the Netherlands) since 1975. We used a discrete time survival model to calculate the cumulative probability of each major screening outcome over 19 screening rounds. Women with a family history of breast cancer had a higher risk of all screening outcomes. For women screened from age 50–75, the cumulative risk of screen-detected breast cancer, interval cancer and false-positive results were 9.0%, 4.4% and 11.1% for women with a family history and 6.3%, 2.7% and 7.3% for women without a family history, respectively. The results for women 40–75 followed the same pattern for women screened 50–75 for cancer outcomes, but were almost doubled for false-positive results. To conclude, women with a first-degree relative with a history of breast cancer are more likely to experience benefits and harms of screening than women without a family history. To complete the balance and provide risk-based screening recommendations, the breast cancer mortality reduction and overdiagnosis should be estimated for family history subgroups. PMID:26537645

  8. Towards personalized screening: Cumulative risk of breast cancer screening outcomes in women with and without a first-degree relative with a history of breast cancer.

    PubMed

    Ripping, Theodora Maria; Hubbard, Rebecca A; Otten, Johannes D M; den Heeten, Gerard J; Verbeek, André L M; Broeders, Mireille J M

    2016-04-01

    Several reviews have estimated the balance of benefits and harms of mammographic screening in the general population. The balance may, however, differ between individuals with and without family history. Therefore, our aim is to assess the cumulative risk of screening outcomes; screen-detected breast cancer, interval cancer, and false-positive results, in women screenees aged 50-75 and 40-75, with and without a first-degree relative with a history of breast cancer at the start of screening. Data on screening attendance, recall and breast cancer detection were collected for each woman living in Nijmegen (The Netherlands) since 1975. We used a discrete time survival model to calculate the cumulative probability of each major screening outcome over 19 screening rounds. Women with a family history of breast cancer had a higher risk of all screening outcomes. For women screened from age 50-75, the cumulative risk of screen-detected breast cancer, interval cancer and false-positive results were 9.0, 4.4 and 11.1% for women with a family history and 6.3, 2.7 and 7.3% for women without a family history, respectively. The results for women 40-75 followed the same pattern for women screened 50-75 for cancer outcomes, but were almost doubled for false-positive results. To conclude, women with a first-degree relative with a history of breast cancer are more likely to experience benefits and harms of screening than women without a family history. To complete the balance and provide risk-based screening recommendations, the breast cancer mortality reduction and overdiagnosis should be estimated for family history subgroups. © 2015 UICC.

  9. Insensitivity of the "Romberg test of standing balance on firm and compliant support surfaces" to the results of caloric and VEMP tests.

    PubMed

    Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren

    2011-01-01

    The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.

  10. Azithromycin treatment failure for Chlamydia trachomatis among heterosexual men with nongonococcal urethritis

    PubMed Central

    Kissinger, Patricia; White, Scott; Manhart, Lisa E.; Schwebke, Jane; Taylor, Stephanie N; Mena, Leandro; Khosropour, Christine M; Wilcox, Larissa; Schmidt, Norine; Martin, David H

    2016-01-01

    Background Three recent prospective studies have suggested that the 1 g dose of azithromycin for Chlamydia trachomatis (Ct) was less effective than expected, reporting a wide range of treatment failure rates (5.8%–22.6%). Reasons for the disparate results could be attributed to geographic or methodological differences. The purpose of this study was to re-examine the studies and attempt to harmonize methodologies to reduce misclassification as a result of false positives from early test-of-cure (TOC) or reinfection as a result of sexual exposure rather than treatment failure. Methods Men who had sex with women, who received 1 g azithromycin under directly observed therapy (DOT) for presumptive treatment of nongonococcal urethritis (NGU) with confirmed Ct were included. Baseline screening was performed on urethral swabs or urine and TOC screening was performed on urine using nucleic acid amplification tests (NAAT). Post-treatment vaginal sexual exposure was elicited at TOC. Data from the three studies was obtained and re-analyzed. Rates of Ct re-test positive were examined for all cases and a sensitivity analysis was conducted to either reclassify potential false positives/reinfections as negative or remove them from the analysis. Results The crude treatment failure rate was 12.8% (31/242). The rate when potential false positives/reinfections were reclassified as negative was 6.2% (15/242) or when these were excluded from analysis was 10.9% (15/138). Conclusion In these samples of men who have sex with women with Ct-related NGU, azithromycin treatment failure was between 6.2% and 12.8%. This range of failure is lower than previously published but higher than the desired World Health Organization’s target chlamydia treatment failure rate of < 5%. PMID:27631353

  11. Development and experimental test of support vector machines virtual screening method for searching Src inhibitors from large compound libraries.

    PubMed

    Han, Bucong; Ma, Xiaohua; Zhao, Ruiying; Zhang, Jingxian; Wei, Xiaona; Liu, Xianghui; Liu, Xin; Zhang, Cunlong; Tan, Chunyan; Jiang, Yuyang; Chen, Yuzong

    2012-11-23

    Src plays various roles in tumour progression, invasion, metastasis, angiogenesis and survival. It is one of the multiple targets of multi-target kinase inhibitors in clinical uses and trials for the treatment of leukemia and other cancers. These successes and appearances of drug resistance in some patients have raised significant interest and efforts in discovering new Src inhibitors. Various in-silico methods have been used in some of these efforts. It is desirable to explore additional in-silico methods, particularly those capable of searching large compound libraries at high yields and reduced false-hit rates. We evaluated support vector machines (SVM) as virtual screening tools for searching Src inhibitors from large compound libraries. SVM trained and tested by 1,703 inhibitors and 63,318 putative non-inhibitors correctly identified 93.53%~ 95.01% inhibitors and 99.81%~ 99.90% non-inhibitors in 5-fold cross validation studies. SVM trained by 1,703 inhibitors reported before 2011 and 63,318 putative non-inhibitors correctly identified 70.45% of the 44 inhibitors reported since 2011, and predicted as inhibitors 44,843 (0.33%) of 13.56M PubChem, 1,496 (0.89%) of 168 K MDDR, and 719 (7.73%) of 9,305 MDDR compounds similar to the known inhibitors. SVM showed comparable yield and reduced false hit rates in searching large compound libraries compared to the similarity-based and other machine-learning VS methods developed from the same set of training compounds and molecular descriptors. We tested three virtual hits of the same novel scaffold from in-house chemical libraries not reported as Src inhibitor, one of which showed moderate activity. SVM may be potentially explored for searching Src inhibitors from large compound libraries at low false-hit rates.

  12. Determination of 105 antibiotic, anti-inflammatory, antiparasitic agents and tranquilizers by LC-MS/MS based on an acidic QuEChERS-like extraction.

    PubMed

    Desmarchelier, Aurélien; Fan, Kaïli; Minh Tien, Mai; Savoy, Marie-Claude; Tarres, Adrienne; Fuger, Denis; Goyon, Alexandre; Bessaire, Thomas; Mottier, Pascal

    2018-04-01

    A procedure for screening 105 veterinary drugs in foods by liquid chromatography tandem mass-spectrometry (LC-MS/MS) is presented. Its scope encompasses raw materials of animal origin (milk, meat, fish, egg and fat) but also related processed ingredients and finished products commonly used and manufactured by food business operators. Due to the complexity of the matrices considered and to efficiently deal with losses during extraction and matrix effects during MS source ionisation, each sample was analysed twice, that is 'unspiked' and 'spiked at the screening target concentration' using a QuEChERS-like extraction. The entire procedure was validated according to the European Community Reference Laboratories Residues Guidelines. False-negative and false-positive rates were below 5% for all veterinary drugs whatever the food matrix. Effectiveness of the procedure was further demonstrated through participation to five proficiency tests and its ruggedness demonstrated in quality control operations by a second laboratory.

  13. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  14. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  15. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  16. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  17. 28 CFR 904.3 - State criminal history record screening standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false State criminal history record screening... STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.3 State criminal history record screening standards. The following record screening standards relate to criminal history record information received...

  18. Preparation of milk samples for immunoassay and liquid chromatographic screening using matrix solid-phase dispersion.

    PubMed

    Barker, S A; Long, A R

    1994-01-01

    The use of drugs to maintain the health and maximize the output of dairy cattle has made the monitoring of milk for such agents essential. Screening tests based on immunological, microbial inhibition, and bacterial receptor assays have been developed for the detection of violative levels of therapeutic substances. However, such assays are not infallible, and false positive or negative results can occur when contaminants bind receptors or compete for the binding of the target residues. Such effects may arise from dietary sources, diseases, or other variables. Thus, a violation by such a test is not definitive until further confirmation is obtained. Our laboratory has developed extraction procedures for several drugs used in dairy production. Our method uses matrix solid-phase dispersion (MSPD) to isolate drugs away from contaminants and to eliminate many possible interferences. MSPD can also be used to enhance the specificity of such assays by fractionating various classes of drugs that may cross-react. Similarly, such methods may be used for liquid chromatographic screening and confirmation of a suspect sample.

  19. Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features.

    PubMed

    Castells, Xavier; Torá-Rocamora, Isabel; Posso, Margarita; Román, Marta; Vernet-Tomas, Maria; Rodríguez-Arana, Ana; Domingo, Laia; Vidal, Carmen; Baré, Marisa; Ferrer, Joana; Quintana, María Jesús; Sánchez, Mar; Natal, Carmen; Espinàs, Josep A; Saladié, Francina; Sala, María

    2016-08-01

    Purpose To assess the risk of breast cancer in women with false-positive screening results according to radiologic classification of mammographic features. Materials and Methods Review board approval was obtained, with waiver of informed consent. This retrospective cohort study included 521 200 women aged 50-69 years who underwent screening as part of the Spanish Breast Cancer Screening Program between 1994 and 2010 and who were observed until December 2012. Cox proportional hazards regression analysis was used to estimate the age-adjusted hazard ratio (HR) of breast cancer and the 95% confidence interval (CI) in women with false-positive mammograms as compared with women with negative mammograms. Separate models were adjusted for screen-detected and interval cancers and for screen-film and digital mammography. Time without a breast cancer diagnosis was plotted by using Kaplan-Meier curves. Results When compared with women with negative mammograms, the age-adjusted HR of cancer in women with false-positive results was 1.84 (95% CI: 1.73, 1.95; P < .001). The risk was higher in women who had calcifications, whether they were (HR, 2.73; 95% CI: 2.28, 3.28; P < .001) or were not (HR, 2.24; 95% CI: 2.02, 2.48; P < .001) associated with masses. Women in whom mammographic features showed changes in subsequent false-positive results were those who had the highest risk (HR, 9.13; 95% CI: 8.28, 10.07; P < .001). Conclusion Women with false-positive results had an increased risk of breast cancer, particularly women who had calcifications at mammography. Women who had more than one examination with false-positive findings and in whom the mammographic features changed over time had a highly increased risk of breast cancer. Previous mammographic features might yield useful information for further risk-prediction models and personalized follow-up screening protocols. (©) RSNA, 2016 Online supplemental material is available for this article.

  20. Improving Universal Suicide Prevention Screening in Primary Care by Reducing False Negatives

    DTIC Science & Technology

    2016-09-01

    AWARD NUMBER: W81XWH-14-1-0272 TITLE: Improving universal suicide prevention screening in primary care by reducing false negatives PRINCIPAL...COVERED 9/1/2015-8/31/2016 4. TITLE AND SUBTITLE Improving universal suicide prevention screening in primary care by 5a. CONTRACT NUMBER reducing...proposed project is to develop a shortened version of the Suicide Cognitions Scale (SCS) and to evaluate its efficacy as a universal suicide prevention

  1. More than just T₄: diagnostic testing for hyperthyroidism in cats.

    PubMed

    Peterson, Mark E

    2013-09-01

    In older cats presenting with clinical features of hyperthyroidism, confirmation of a diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests (especially in the context of routine screening of asymptomatic cats) and leads to clinical dilemmas. For example, a high serum T₄ value may be found in a cat that lacks clinical signs of hyperthyroidism, or hyperthyroidism may be suspected in a cat with normal total T₄ concentrations. To avoid unnecessary treatment and potentially adverse effects in a euthyroid cat, thyroid function tests must always be interpreted in the light of the cat's history, clinical signs, physical examination findings and other laboratory findings. In this article the author reviews the use of commonly recommended thyroid function tests, focusing on clinical scenarios that present diagnostic difficulties. In doing so, he draws on the veterinary and comparative literature, his own clinical experience, and data, unpublished to date, obtained from a series of 100 hyperthyroid cats consecutively diagnosed at his clinic.

  2. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    PubMed

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  3. Clinical sensitivity and specificity of the Check-Points Check-Direct ESBL Screen for BD MAX, a real-time PCR for direct ESBL detection from rectal swabs.

    PubMed

    Souverein, Dennis; Euser, Sjoerd M; van der Reijden, Wil A; Herpers, Bjorn L; Kluytmans, Jan; Rossen, John W A; Den Boer, Jeroen W

    2017-09-01

    To determine the diagnostic accuracy of the Check-Direct ESBL Screen for BD MAX (ESBL qPCR) and an ESBL culture method to identify ESBLs directly from rectal swabs. Rectal swabs were obtained from clinical patients by performing cross-sectional (point)prevalence measurements in three regional hospitals. Rectal swabs were analysed by direct culture (ChromID ESBL agar) and with the ESBL qPCR. Suspected ESBL-producing isolates were confirmed with the combination disc method and analysed by WGS. Out of 354 rectal swabs and 351 patients, 21 rectal swabs and 20 patients were positive for ESBL-producing isolates, resulting in a regional ESBL colonization prevalence of 5.7%. One rectal swab was false negative with the ESBL qPCR (blaTEM-12) and not covered by the ESBL qPCR. Eight ESBL qPCR-positive rectal swabs could not be confirmed by culture and were classified as false ESBL qPCR positive. The sensitivity and specificity of the ESBL qPCR were 95.2% (n = 20) and 97.6% (n = 323), respectively. When an optimal cycle threshold cut-off value of 37 was used, the ESBL qPCR displayed a sensitivity and specificity of 95.2% (n = 20) and 98.8% (n = 327), respectively (AUC = 0.975, 95% CI = 0.922-1). This ESBL qPCR offers rapid direct detection of the most prevalent ESBL types (blaCTX-M group and blaSHV group) from rectal swabs. The relatively high false-positive rate renders this test the most suitable as a screening test in high-prevalence regions or in an outbreak setting where a fast result is essential. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Canine cancer screening via ultraviolet absorbance and fluorescence spectroscopy of serum proteins

    NASA Astrophysics Data System (ADS)

    Dickerson, Bryan D.; Geist, Brian L.; Spillman, William B., Jr.; Robertson, John L.

    2007-11-01

    A cost-effective optical cancer screening and monitoring technique was demonstrated in a pilot study of canine serum samples and was patented for commercialization. Compared to conventional blood chemistry analysis methods, more accurate estimations of the concentrations of albumin, globulins, and hemoglobin in serum were obtained by fitting the near UV absorbance and photoluminescence spectra of diluted serum as a linear combination of component reference spectra. Tracking these serum proteins over the course of treatment helped to monitor patient immune response to carcinoma and therapy. For cancer screening, 70% of dogs with clinical presentation of cancer displayed suppressed serum hemoglobin levels (below 20 mg/dL) in combination with atypical serum protein compositions, that is, albumin levels outside of a safe range (from 4 to 8 g/dL) and globulin levels above or below a more normal range (from 1.7 to 3.7 g/dL). Of the dogs that met these criteria, only 20% were given a false positive label by this cancer screening test.

  5. Detection, prevention, and rehabilitation of amblyopia.

    PubMed

    Spiritus, M

    1997-10-01

    The necessity of visual preschool screening for reducing the prevalence of amblyopia is widely accepted. The beneficial results of large-scale screening programs conducted in Scandinavia are reported. Screening monocular visual acuity at 3.5 to 4 years of age appears to be an excellent basis for detecting and treating amblyopia and an acceptable compromise between the pitfalls encountered in screening younger children and the cost-to-benefit ratio. In this respect, several preschoolers' visual acuity charts have been evaluated. New recently developed small-target random stereotests and binocular suppression tests have also been developed with the aim of correcting the many false negatives (anisometropic amblyopia or bilateral high ametropia) induced by the usual stereotests. Longitudinal studies demonstrate that correction of high refractive errors decreases the risk of amblyopia and does not impede emmetropization. The validity of various photoscreening and videoscreening procedures for detecting refractive errors in infants prior to the onset of strabismus or amblyopia, as well as alternatives to conventional occlusion therapy, is discussed.

  6. Cell-free DNA screening in clinical practice: abnormal autosomal aneuploidy and microdeletion results.

    PubMed

    Valderramos, Stephanie G; Rao, Rashmi R; Scibetta, Emily W; Silverman, Neil S; Han, Christina S; Platt, Lawrence D

    2016-11-01

    Since its commercial release in 2011 cell-free DNA screening has been rapidly adopted as a routine prenatal genetic test. However, little is known about its performance in actual clinical practice. We sought to investigate factors associated with the accuracy of abnormal autosomal cell-free DNA results. We conducted a retrospective cohort study of 121 patients with abnormal cell-free DNA results from a referral maternal-fetal medicine practice from March 2013 through July 2015. Patients were included if cell-free DNA results for trisomy 21, trisomy 18, trisomy 13, or microdeletions (if reported by the laboratory) were positive or nonreportable. The primary outcome was confirmed aneuploidy or microarray abnormality on either prenatal or postnatal karyotype or microarray. Secondary outcomes were identifiable associations with in vitro fertilization, twins, ultrasound findings, testing platform, and testing laboratory. Kruskal-Wallis or Fisher exact tests were used as appropriate. A total of 121 patients had abnormal cell-free DNA results for trisomy 21, trisomy 18, trisomy 13, and/or microdeletions. In all, 105 patients had abnormal cell-free DNA results for trisomy 21, trisomy 18, and trisomy 13. Of these, 92 (87.6%) were positive and 13 (12.4%) were nonreportable. The results of the 92 positive cell-free DNA were for trisomy 21 (48, 52.2%), trisomy 18 (22, 23.9%), trisomy 13 (17, 18.5%), triploidy (2, 2.2%), and positive for >1 parameter (3, 3.3%). Overall, the positive predictive value of cell-free DNA was 73.5% (61/83; 95% confidence interval, 63-82%) for all trisomies (by chromosome: trisomy 21, 83.0% [39/47; 95% confidence interval, 69-92%], trisomy 18, 65.0% [13/20; 95% confidence interval, 41-84%], and trisomy 13, 43.8% [7/16; 95% confidence interval, 21-70%]). Abnormal cell-free DNA results were associated with positive serum screening (by group: trisomy 21 [17/48, 70.8%]; trisomy 18 [7/22, 77.8%]; trisomy 13 [3/17, 37.5%]; nonreportable [2/13, 16.7%]; P = .004), and abnormal first-trimester ultrasound (trisomy 21 [25/45, 55.6%]; trisomy 18 [13/20, 65%]; trisomy 13 [6/14, 42.9%]; nonreportable [1/13, 7.7%]; P = .003). There was no association between false-positive rates and testing platform, but there was a difference between the 4 laboratories (P = .018). In all, 26 patients had positive (n = 9) or nonreportable (n = 17) microdeletion results. Seven of 9 screens positive for microdeletions underwent confirmatory testing; all were false positives. The positive predictive value of 73.5% for cell-free DNA screening for autosomal aneuploidy is lower than reported. The positive predictive value for microdeletion testing was 0%. Diagnostic testing is needed to confirm abnormal cell-free DNA results for aneuploidy and microdeletions. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Where Have All the Interactions Gone? Estimating the Coverage of Two-Hybrid Protein Interaction Maps

    PubMed Central

    Huang, Hailiang; Jedynak, Bruno M; Bader, Joel S

    2007-01-01

    Yeast two-hybrid screens are an important method for mapping pairwise physical interactions between proteins. The fraction of interactions detected in independent screens can be very small, and an outstanding challenge is to determine the reason for the low overlap. Low overlap can arise from either a high false-discovery rate (interaction sets have low overlap because each set is contaminated by a large number of stochastic false-positive interactions) or a high false-negative rate (interaction sets have low overlap because each misses many true interactions). We extend capture–recapture theory to provide the first unified model for false-positive and false-negative rates for two-hybrid screens. Analysis of yeast, worm, and fly data indicates that 25% to 45% of the reported interactions are likely false positives. Membrane proteins have higher false-discovery rates on average, and signal transduction proteins have lower rates. The overall false-negative rate ranges from 75% for worm to 90% for fly, which arises from a roughly 50% false-negative rate due to statistical undersampling and a 55% to 85% false-negative rate due to proteins that appear to be systematically lost from the assays. Finally, statistical model selection conclusively rejects the Erdös-Rényi network model in favor of the power law model for yeast and the truncated power law for worm and fly degree distributions. Much as genome sequencing coverage estimates were essential for planning the human genome sequencing project, the coverage estimates developed here will be valuable for guiding future proteomic screens. All software and datasets are available in Datasets S1 and S2, Figures S1–S5, and Tables S1−S6, and are also available from our Web site, http://www.baderzone.org. PMID:18039026

  8. Barriers to postpartum screening for type 2 diabetes: a qualitative study of women with previous gestational diabetes.

    PubMed

    Rafii, Forough; Rahimparvar, Seyedeh Fatemeh Vasegh; Mehrdad, Neda; Keramat, Afsaneh

    2017-01-01

    Risk of developing type 2 diabetes is increased in women with previous gestational diabetes mellitus (GDM). Postpartum glycemic screening is recommended in women with recent GDM. But this screening rate is low and the reasons are unclear. The aim of this study was to explore the experiences of Iranian women with recent GDM on barriers of postpartum screening for diabetes. This qualitative study was conducted in Tehran, Iran in 2016. Semi-structured interview was used for data collection. 22 women with recent GDM were interviewed. These women gave birth in Tehran hospitals at a minimum of 6 months before interview. The missed screening defined as not attending to laboratory for Fasting Blood Sugar and/or Oral Glucose Tolerance Test, 6 week to 6 month after their child birthing. The data was analyzed by content analysis method. Themes and sub-themes that illustrated the barriers to postpartum diabetes screening were: inadequate education (about developing diabetes in the future, implementation of the screening, and glucometer validity in diagnosis of diabetes), perceiving the screening as difficult (feeling comfortable with the glucometer, poor laboratory conditions, issues related to the baby/babies, and financial problems), improper attitudes toward the screening (unwilling to get diagnosed, not giving priority to oneself, having false beliefs) and procrastination (gap to intention and action, self-deception and self-regulation failure). Women with recent GDM reported several barriers for postpartum diabetes screening. This study help to develop the evidence-based interventions for improving this screening rate.

  9. Neonatal hypothyroid screening in monitoring of iodine deficiency and iodine supplementation in Poland.

    PubMed

    Ołtarzewski, M; Szymborski, J

    2003-01-01

    Neonatal hypothyroid screening in Poland is standardised and all newborns screening data are registered in central data base in the National Institute of Mother and Child. About 400,000 newborns are screened per year for hypothyroidism (TSH) and phenylketonuria (PKU). Unfortunately, obstetric clinics still use antiseptics that contain iodine. According to our data 71% of clinics used iodine in 1998 (58% iodine tincture and 13% povidone iodine) and 58.2% (35.4 iodine tincture and 13% povidone iodine) in the year 2000. Presence of iodine resulted in over 3 times increase of a percentage of TSH levels over cut off, increasing the number of false positives in the hypothyroid screening. Analysis of TSH distribution for iodine containing and iodine free hospitals gave totally different estimation of iodine deficiency according to WHO criteria. In the group of iodine free hospitals 24 regions were classified as not deficient, 9 regions were borderline with a fraction of TSH levels over 5 mlU/l of 3-5%. 10 regions could not be analysed because all hospitals declared use of iodine. In the second group all regions were iodine deficient. TSH distribution since 1994 shows significant decrease of percentage of TSH levels over cut off from 2.23% in 1994 to 0.16 in 1997 and to 0.12 in 2000. These changes are most probably connected with successive introduction of iodine supplementation which became obligatory in 1997 and suggest that iodine supplementation covers iodine requirements during pregnancy. Iodine deficiency and iodine supplementation in Poland can be studied using TSH blood spot newborn screening results in correlation with data on interfering factors and in reference to modified criteria for the analytical test and the population. To reduce false positive rate in neonatal hypothyroid screening iodine containing antiseptics, particularly iodine tincture, should be withdrawn from all obstetrics clinics in Poland.

  10. Deciding on PSA-screening - Quality of current consumer information on the Internet.

    PubMed

    Korfage, Ida J; van den Bergh, Roderick C N; Essink-Bot, Marie-Louise

    2010-11-01

    Given that screening for prostate cancer has the potential to reduce prostate cancer mortality at the expense of considerable overdiagnosis and overtreatment, the availability of core consumer information - correct, balanced and supportive of autonomous decision-making - is a must. We assessed the quality of consumer information available through the Internet per November 2009 and its possible contribution to informed decision-making by potential screenees. Consumer information on PSA-screening was sought through the Internet in November 2009. Materials had to be targeted at potential consumers, offered by not-for-profit organisations, released in 2005 or after, in English or Dutch. Per material 2 of the authors assessed independently from each other whether standardised pre-defined topics were addressed, whether the content was correct and which approach was taken towards the decision-making process about uptake. Twenty-three materials were included, of which 11 were released (shortly) after the results of 2 large randomized-controlled trials (RCTs) that evaluated the effectiveness of screening for prostate cancer had been published in March 2009. That a PSA-test result can be abnormal because of non-cancerous conditions (false positive) and that it may miss prostate cancer (false negative) was not addressed in 2/23 and 8/23 materials, respectively. The risk of overdiagnosis and overtreatment was not mentioned in 6 out of 23. PSA-screening was presented as a usual thing to do in some materials, whereas other materials emphasised the voluntary nature of PSA-screening ('it is your decision'). The content of 19/23 materials was considered sufficiently informative according to the pre-defined criteria, 12/23 materials were considered supportive of informed decision-making by men. Most materials of not-for-profit organizations supplied adequate information about PSA-screening, whilst the degree of persuasion towards uptake reflected variations in opinions on men's autonomy regarding their own health. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. A systematic review of screening questionnaires for childhood lead poisoning.

    PubMed

    Ossiander, Eric M

    2013-01-01

    The Centers for Disease Control and Prevention encourages the use of risk factor questionnaires to screen children for lead poisoning. A majority of state health departments have formal lead screening guidelines that recommend health care providers use questionnaires. We conducted a systematic review to evaluate the ability of lead screening questionnaires to predict lead poisoning risk among children. Articles that reported the evaluation of a predesigned lead screening questionnaire were obtained by searching Medline/PubMed and by examining references of articles obtained through the online search. From each evaluation, we abstracted the number of children that were true positive, false positive, true negative, and false negative, according to the results of the screening questionnaire and the follow-up blood lead test. From these data, we calculated specificity and sensitivity of the questionnaire for each evaluation. Twenty articles met the inclusion criteria: these included 28 separate questionnaire evaluations. Among 17 evaluations of the 1991 Centers for Disease Control and Prevention questionnaire, sensitivity ranged from 0.25 to 0.87, specificity from 0.31 to 0.80, and accuracy (sum of sensitivity and specificity) from 0.74 to 1.39. The pooled mean estimates for this questionnaire were sensitivity 0.61 (95% confidence interval: 0.53-0.68); specificity 0.52 (0.45-0.60); accuracy 1.12 (1.06-1.18). Among 11 evaluations of all other questionnaires, sensitivity ranged from 0.43 to 0.90, specificity from 0.17 to 0.66, and accuracy from 0.94 to 1.27. For these questionnaires, the pooled mean estimates were sensitivity 0.76 (0.68-0.85), specificity 0.41 (0.33-0.49), and accuracy 1.12 (1.06-1.18). Lead screening questionnaires showed a wide range of sensitivity and specificity and performed little better than chance at predicting lead poisoning risk among children.

  12. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Pichini, Simona; Gottardi, Massimo; Marchei, Emilia; Svaizer, Fiorenza; Pellegrini, Manuela; Rotolo, Maria Concetta; Algar, Oscar García; Pacifici, Roberta

    2014-05-01

    Drug testing in hair is a unique analysis in pharmacotoxicology for establishing a past repeated history of consumption or passive exposure to psychotropic substances. A rather lengthy sample treatment is usually required before parent drugs and eventual metabolites are amenable to quali-quantitative analysis. We evaluated a high throughput screening and confirmation analysis of drugs of abuse in hair by immunoassay and a validated ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) after applying a rapid digestion of the keratin matrix with VMA-T reagent before screening assay and M3 reagent before confirmatory analysis. Samples digestion with VMA-T reagent and immunometric screening analysis of hair calibrators, controls and clinical samples for a total of 150 samples was completed in 4 h. No false-positive and -negative results were found for the control material. UPLC-MS/MS analysis confirmed all of the 31 adult hair samples positive to the screening test using internationally established cut-offs, and identified and quantified drugs of abuse in 32 pediatric hair samples, applying lower limits of quantification from 0.01 to 0.1 ng analyte per mg hair. Analytical recovery was between 70.9% and 100.7%. Intra- and inter-assay imprecision and inaccuracy were always lower than 10%. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and UPLC-MS/MS was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in hair in epidemiological studies.

  13. 20 CFR 654.408 - Screening.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Screening. 654.408 Section 654.408 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.408 Screening. (a) All outside openings shall be protected with screening of not less than 16 mesh. (b) All screen doors shall be...

  14. The international experience of bacterial screen testing of platelet components with an automated microbial detection system: a need for consensus testing and reporting guidelines.

    PubMed

    Benjamin, Richard J; McDonald, Carl P

    2014-04-01

    The BacT/ALERT microbial detection system (bioMerieux, Inc, Durham, NC) is in routine use in many blood centers as a prerelease test for platelet collections. Published reports document wide variation in practices and outcomes. A systematic review of the English literature was performed to describe publications assessing the use of the BacT/ALERT culture system on platelet collections as a routine screen test of more than 10000 platelet components. Sixteen publications report the use of confirmatory testing to substantiate initial positive culture results but use varying nomenclature to classify the results. Preanalytical and analytical variables that may affect the outcomes differ widely between centers. Incomplete description of protocol details complicates comparison between sites. Initial positive culture results range from 539 to 10606 per million (0.054%-1.061%) and confirmed positive from 127 to 1035 per million (0.013%-0.104%) donations. False-negative results determined by outdate culture range from 662 to 2173 per million (0.066%-0.217%) and by septic reactions from 0 to 66 per million (0%-0.007%) collections. Current culture protocols represent pragmatic compromises between optimizing analytical sensitivity and ensuring the timely availability of platelets for clinical needs. Insights into the effect of protocol variations on outcomes are generally restricted to individual sites that implement limited changes to their protocols over time. Platelet manufacturers should reassess the adequacy of their BacT/ALERT screening protocols in light of the growing international experience and provide detailed documentation of all variables that may affect culture outcomes when reporting results. We propose a framework for a standardized nomenclature for reporting of the results of BacT/ALERT screening. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Needs for Professional Education to Optimize Cervical Cancer Screenings in Low-Income Countries: a Case Study from Tanzania.

    PubMed

    Lavelle, Anne E; Su, Dejun; Kahesa, Crispin; Soliman, Amr S

    2017-09-11

    Cervical cancer is a significant health problem in many developing countries. Due to limited treatment facilities for cancer in Tanzania, a screening referral program was developed between two urban clinics and Ocean Road Cancer Institute (ORCI), the only cancer treatment center in Tanzania. This study aimed to evaluate the effectiveness of the program and to identify opportunities for professional education. The study included 139 patients who were referred to ORCI from the screening clinics of Magomeni and Temeke between January 2015 and May 2016. Abstracted data from the medical records included patient age, screening results, and treatment. Eight nurses performing screening at the three locations were interviewed about their screening experience. Over half of the referrals (51.9%) were false positives. False positive diagnosis was more common among younger patients (35.68 ± 8.6 years) (p < 0.001) and those referred from Magomeni (59.8%) (p < 0.01) than referrals of older patients (42.46 ± 11.1 years) or those from Temeke (33.3%). Interviews of nurses showed differences among clinics, including resources, experience, and documentation of screening results. The high false positive rates and the variation of accuracy of screening between the two clinics showed a need for professional education of nurses and improvement in the health systems. Continuous education of nurses may increase the effectiveness of cervical screening. Health system enhancement of screening facilities such as provision of Lugol's iodine, more space for screening, and consistency and completion of screening records are needed to increase the accuracy of cervical screening and referrals in Tanzania and other similar low-income countries.

  16. A false sense of security? Can tiered approach be trusted to accurately classify immunogenicity samples?

    PubMed

    Jaki, Thomas; Allacher, Peter; Horling, Frank

    2016-09-05

    Detecting and characterizing of anti-drug antibodies (ADA) against a protein therapeutic are crucially important to monitor the unwanted immune response. Usually a multi-tiered approach that initially rapidly screens for positive samples that are subsequently confirmed in a separate assay is employed for testing of patient samples for ADA activity. In this manuscript we evaluate the ability of different methods used to classify subject with screening and competition based confirmatory assays. We find that for the overall performance of the multi-stage process the method used for confirmation is most important where a t-test is best when differences are moderate to large. Moreover we find that, when differences between positive and negative samples are not sufficiently large, using a competition based confirmation step does yield poor classification of positive samples. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Tumor phenotype and breast density in distinct categories of interval cancer: results of population-based mammography screening in Spain

    PubMed Central

    2014-01-01

    Introduction Interval cancers are tumors arising after a negative screening episode and before the next screening invitation. They can be classified into true interval cancers, false-negatives, minimal-sign cancers, and occult tumors based on mammographic findings in screening and diagnostic mammograms. This study aimed to describe tumor-related characteristics and the association of breast density and tumor phenotype within four interval cancer categories. Methods We included 2,245 invasive tumors (1,297 screening-detected and 948 interval cancers) diagnosed from 2000 to 2009 among 645,764 women aged 45 to 69 who underwent biennial screening in Spain. Interval cancers were classified by a semi-informed retrospective review into true interval cancers (n = 455), false-negatives (n = 224), minimal-sign (n = 166), and occult tumors (n = 103). Breast density was evaluated using Boyd’s scale and was conflated into: <25%; 25 to 50%; 50 to 75%; >75%. Tumor-related information was obtained from cancer registries and clinical records. Tumor phenotype was defined as follows: luminal A: ER+/HER2- or PR+/HER2-; luminal B: ER+/HER2+ or PR+/HER2+; HER2: ER-/PR-/HER2+; triple-negative: ER-/PR-/HER2-. The association of tumor phenotype and breast density was assessed using a multinomial logistic regression model. Adjusted odds ratios (OR) and 95% confidence intervals (95% CI) were calculated. All statistical tests were two-sided. Results Forty-eight percent of interval cancers were true interval cancers and 23.6% false-negatives. True interval cancers were associated with HER2 and triple-negative phenotypes (OR = 1.91 (95% CI:1.22-2.96), OR = 2.07 (95% CI:1.42-3.01), respectively) and extremely dense breasts (>75%) (OR = 1.67 (95% CI:1.08-2.56)). However, among true interval cancers a higher proportion of triple-negative tumors was observed in predominantly fatty breasts (<25%) than in denser breasts (28.7%, 21.4%, 11.3% and 14.3%, respectively; <0.001). False-negatives and occult tumors had similar phenotypic characteristics to screening-detected cancers, extreme breast density being strongly associated with occult tumors (OR = 6.23 (95% CI:2.65-14.66)). Minimal-sign cancers were biologically close to true interval cancers but showed no association with breast density. Conclusions Our findings revealed that both the distribution of tumor phenotype and breast density play specific and independent roles in each category of interval cancer. Further research is needed to understand the biological basis of the overrepresentation of triple-negative phenotype among predominantly fatty breasts in true interval cancers. PMID:24410848

  18. Implementation of maternal blood cell-free DNA testing in early screening for aneuploidies.

    PubMed

    Gil, M M; Quezada, M S; Bregant, B; Ferraro, M; Nicolaides, K H

    2013-07-01

    To explore the feasibility of routine maternal blood cell-free (cf) DNA testing in screening for trisomies 21, 18 and 13 at 10 weeks' gestation. In this prospective study, women attending The Fetal Medicine Centre in London, UK, between October 2012 and April 2013, with singleton pregnancy and live fetus with CRL 32-45 mm, were screened for trisomies 21, 18 and 13 by cfDNA testing at 10 weeks and the combined test at 12 weeks. cfDNA testing was performed in 1005 singleton pregnancies with a median maternal age of 37 (range, 20-49) years. Risks for trisomies were provided for 957 (95.2%) cases and in 98.0% these were available within 14 days from sampling. In 48 (4.8%) cases no result was provided due to problems with delivery to the laboratory, low fetal fraction or assay failure. Repeat sampling was performed in 40 cases and a result obtained in 27 (67.5%) of these. In 11 cases the risk score for trisomy 21 and in five cases that for trisomy 18 was > 99%, in one the risk for trisomy 13 was 34% and in 968 the risk for each of the three trisomies was < 0.01%. The suspected trisomies were confirmed by karyotyping after chorionic villus sampling (CVS), except in one case of trisomy 18 in which the karyotype was normal. On the basis of the maternal age distribution of the study population, the expected and observed numbers for each of the three trisomies were similar. Both cfDNA and combined testing detected all trisomies, but the estimated false-positive rates (FPR) were 0.1% and 3.4%, respectively. Routine screening for trisomies 21, 18 and 13 by cfDNA testing at 10 weeks is feasible and has a lower FPR than does combined testing, but abnormal results require confirmation by CVS. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.

  19. Identifying Metabolically Active Chemicals Using a Consensus ...

    EPA Pesticide Factsheets

    Traditional toxicity testing provides insight into the mechanisms underlying toxicological responses but requires a high investment in a large number of resources. The new paradigm of testing approaches involves rapid screening studies able to evaluate thousands of chemicals across hundreds of biological targets through use of in vitro assays. Endocrine disrupting chemicals (EDCs) are of concern due to their ability to alter neurodevelopment, behavior, and reproductive success of humans and other species. A recent integrated computational model examined results across 18 ER-related assays in the ToxCast in vitro screening program to eliminate chemicals that produce a false signal by possibly interfering with the technological attributes of an individual assay. However, in vitro assays can also lead to false negatives when the complex metabolic processes that render a chemical bioactive in a living system might be unable to be replicated in an in vitro environment. In the current study, the influence of metabolism was examined for over 1,400 chemicals considered inactive using the integrated computational model. Over 2,000 first-generation and over 4,000 second-generation metabolites were generated for the inactive chemicals using in silico techniques. Next, a consensus model comprised of individual structure activity relationship (SAR) models was used to predict ER-binding activity for each of the metabolites. Binding activity was predicted for 8-10% of the meta

  20. Rapid HIV Testing in Dental Practices

    PubMed Central

    Abel, Stephen N.; Pereyra, Margaret; Liguori, Terri; Pollack, Harold A.; Metsch, Lisa R.

    2012-01-01

    Despite increasing discussion about the dental care setting as a logical, potentially fruitful venue for rapid HIV testing, dentists’ willingness to take on this task is unclear. Semistructured interviews with 40 private practice dentists revealed their principal concerns regarding offering patients HIV testing were false results, offending patients, viewing HIV testing as outside the scope of licensure, anticipating low patient acceptance of HIV testing in a dental setting, expecting inadequate reimbursement, and potential negative impact on the practice. Dentists were typically not concerned about transmission risks, staff opposition to testing, or making referrals for follow-up after a positive result. A larger cultural change may be required to engage dentists more actively in primary prevention and population-based HIV screening. PMID:22397342

  1. Screening for fetal growth restriction using fetal biometry combined with maternal biomarkers.

    PubMed

    Gaccioli, Francesca; Aye, Irving L M H; Sovio, Ulla; Charnock-Jones, D Stephen; Smith, Gordon C S

    2018-02-01

    Fetal growth restriction is a major determinant of perinatal morbidity and mortality. Screening for fetal growth restriction is a key element of prenatal care but it is recognized to be problematic. Screening using clinical risk assessment and targeting ultrasound to high-risk women is the standard of care in the United States and United Kingdom, but the approach is known to have low sensitivity. Systematic reviews of randomized controlled trials do not demonstrate any benefit from universal ultrasound screening for fetal growth restriction in the third trimester, but the evidence base is not strong. Implementation of universal ultrasound screening in low-risk women in France failed to reduce the risk of complications among small-for-gestational-age infants but did appear to cause iatrogenic harm to false positives. One strategy to making progress is to improve screening by developing more sensitive and specific tests with the key goal of differentiating between healthy small fetuses and those that are small through fetal growth restriction. As abnormal placentation is thought to be the major cause of fetal growth restriction, one approach is to combine fetal biometry with an indicator of placental dysfunction. In the past, these indicators were generally ultrasonic measurements, such as Doppler flow velocimetry of the uteroplacental circulation. However, another promising approach is to combine ultrasonic suspicion of small-for-gestational-age infant with a blood test indicating placental dysfunction. Thus far, much of the research on maternal serum biomarkers for fetal growth restriction has involved the secondary analysis of tests performed for other indications, such as fetal aneuploidies. An exemplar of this is pregnancy-associated plasma protein A. This blood test is performed primarily to assess the risk of Down syndrome, but women with low first-trimester levels are now serially scanned in later pregnancy due to associations with placental causes of stillbirth, including fetal growth restriction. The development of "omic" technologies presents a huge opportunity to identify novel biomarkers for fetal growth restriction. The hope is that when such markers are measured alongside ultrasonic fetal biometry, the combination would have strong predictive power for fetal growth restriction and its related complications. However, a series of important methodological considerations in assessing the diagnostic effectiveness of new tests will have to be addressed. The challenge thereafter will be to identify novel disease-modifying interventions, which are the essential partner to an effective screening test to achieve clinically effective population-based screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Optimizing screening for tuberculosis and hepatitis B prior to starting tumor necrosis factor-α inhibitors in Crohn's disease.

    PubMed

    van der Have, Mike; Oldenburg, Bas; Fidder, Herma H; Belderbos, Tim D G; Siersema, Peter D; van Oijen, Martijn G H

    2014-03-01

    Treatment with tumor necrosis factor-α (TNF-α) inhibitors in patients with Crohn's disease (CD) is associated with potentially serious infections, including tuberculosis (TB) and hepatitis B virus (HBV). We assessed the cost-effectiveness of extensive TB screening and HBV screening prior to initiating TNF-α inhibitors in CD. We constructed two Markov models: (1) comparing tuberculin skin test (TST) combined with chest X-ray (conventional TB screening) versus TST and chest X-ray followed by the interferon-gamma release assay (extensive TB screening) in diagnosing TB; and (2) HBV screening versus no HBV screening. Our base-case included an adult CD patient starting with infliximab treatment. Input parameters were extracted from the literature. Direct medical costs were assessed and discounted following a third-party payer perspective. The main outcome was the incremental cost-effectiveness ratio (ICER). Sensitivity and Monte Carlo analyses were performed over wide ranges of probability and cost estimates. At base-case, the ICERs of extensive screening and HBV screening were €64,340 and €75,760 respectively to gain one quality-adjusted life year. Sensitivity analyses concluded that extensive TB screening was a cost-effective strategy if the latent TB prevalence is more than 12 % or if the false positivity rate of TST is more than 20 %. HBV screening became cost-effective if HBV reactivation or HBV-related mortality is higher than 37 and 62 %, respectively. Extensive TB screening and HBV screening are not cost-effective compared with conventional TB screening and no HBV screening, respectively. However, when targeted at high-risk patient groups, these screening strategies are likely to become cost-effective.

  3. Comprehensive CFTR gene analysis of the French cystic fibrosis screened newborn cohort: implications for diagnosis, genetic counseling, and mutation-specific therapy.

    PubMed

    Audrézet, Marie Pierre; Munck, Anne; Scotet, Virginie; Claustres, Mireille; Roussey, Michel; Delmas, Dominique; Férec, Claude; Desgeorges, Marie

    2015-02-01

    Newborn screening (NBS) for cystic fibrosis (CF) was implemented throughout France in 2002. It involves a four-tiered procedure: immunoreactive trypsin (IRT)/DNA/IRT/sweat test [corrected] was implemented throughout France in 2002. The aim of this study was to assess the performance of molecular CFTR gene analysis from the French NBS cohort, to evaluate CF incidence, mutation detection rate, and allelic heterogeneity. During the 8-year period, 5,947,148 newborns were screened for cystic fibrosis. The data were collected by the Association Française pour le Dépistage et la Prévention des Handicaps de l'Enfant. The mutations identified were classified into four groups based on their potential for causing disease, and a diagnostic algorithm was proposed. Combining the genetic and sweat test results, 1,160 neonates were diagnosed as having cystic fibrosis. The corresponding incidence, including both the meconium ileus (MI) and false-negative cases, was calculated at 1 in 4,726 live births. The CF30 kit, completed with a comprehensive CFTR gene analysis, provides an excellent detection rate of 99.77% for the mutated alleles, enabling the identification of a complete genotype in 99.55% of affected neonates. With more than 200 different mutations characterized, we confirmed the French allelic heterogeneity. The very good sensitivity, specificity, and positive predictive value obtained suggest that the four-tiered IRT/DNA/IRT/sweat test procedure may provide an effective strategy for newborn screening for cystic fibrosis.

  4. Prospective audit of a one-centre combined nuchal translucency and triple test programme for the detection of trisomy 21.

    PubMed

    Babbur, Vijayalakshmi; Lees, Christoph C; Goodburn, Sandra F; Morris, Nigel; Breeze, Andrew C G; Hackett, Gerald A

    2005-06-01

    To determine detection and false-positive rates for trisomy 21 using two-stage combined nuchal translucency (NT) and triple testing, whilst disclosing abnormal nuchal measurements at the scan. A prospective audit in a UK women's hospital, of 3188 women with singleton pregnancies, requesting screening for trisomy 21. Median age was 37 years (range 19-46). Women were offered NT screening at 11 to 14 weeks. Those with NT > or =3 mm were offered chorionic villus sampling. Those declining CVS, and those with NT <3 mm, were offered early triple tests. Women with a term combined risk of trisomy 21 > or = 1:250, based on age, NT, and triple test results were offered amniocentesis. Using a 3-mm NT 'cut-off' identified 16/25 cases of trisomy 21 (64%; 95% CI 38.8, 78.9). Of 2725 women who had a combined nuchal plus triple test assessment, 79 (2.6%) had a > or = 1:250 term risk of trisomy 21. Forty (1.3%) had amniocentesis identifying 6/9 remaining cases (67%:95% CI:27.9, 92.5). Overall, the detection rate was 88% (95% CI:68.8, 97.5) for a 4.8% FPR. For the screened population, to achieve an 88% detection rate using the triple test alone, the predicted FPR would be 20%. Conversely, for an FPR of 4.8% using the triple test alone, the detection rate would be only 60%. In a high-risk group, the combination of NT with triple test offers detection of trisomy 21 at least equivalent to either test, while allowing disclosure of an abnormal NT at the scan and reducing the FPR. Importantly, the FPR is less than 5%, considerably lower than expected for triple test alone for this population.

  5. Variation in false-positive rates of mammography reading among 1067 radiologists: a population-based assessment.

    PubMed

    Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L

    2006-12-01

    The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.

  6. Efficacy and effectiveness of screen and treat policies in prevention of type 2 diabetes: systematic review and meta-analysis of screening tests and interventions.

    PubMed

    Barry, Eleanor; Roberts, Samantha; Oke, Jason; Vijayaraghavan, Shanti; Normansell, Rebecca; Greenhalgh, Trisha

    2017-01-04

     To assess diagnostic accuracy of screening tests for pre-diabetes and efficacy of interventions (lifestyle or metformin) in preventing onset of type 2 diabetes in people with pre-diabetes.  Systematic review and meta-analysis.  Medline, PreMedline, and Embase. Study protocols and seminal papers were citation-tracked in Google Scholar to identify definitive trials and additional publications. Data on study design, methods, and findings were extracted onto Excel spreadsheets; a 20% sample was checked by a second researcher. Data extracted for screening tests included diagnostic accuracy and population prevalence. Two meta-analyses were performed, one summarising accuracy of screening tests (with the oral glucose tolerance test as the standard) for identification of pre-diabetes, and the other assessing relative risk of progression to type 2 diabetes after either lifestyle intervention or treatment with metformin.  Empirical studies evaluating accuracy of tests for identification of pre-diabetes. Interventions (randomised trials and interventional studies) with a control group in people identified through screening. No language restrictions.  2874 titles were scanned and 148 papers (covering 138 studies) reviewed in full. The final analysis included 49 studies of screening tests (five of which were prevalence studies) and 50 intervention trials. HbA 1c had a mean sensitivity of 0.49 (95% confidence interval 0.40 to 0.58) and specificity of 0.79 (0.73 to 0.84), for identification of pre-diabetes, though different studies used different cut-off values. Fasting plasma glucose had a mean sensitivity of 0.25 (0.19 to 0.32) and specificity of 0.94 (0.92 to 0.96). Different measures of glycaemic abnormality identified different subpopulations (for example, 47% : of people with abnormal HbA 1c had no other glycaemic abnormality). Lifestyle interventions were associated with a 36% (28% to 43%) reduction in relative risk of type 2 diabetes over six months to six years, attenuating to 20% (8% to 31%) at follow-up in the period after the trails.  HbA 1c is neither sensitive nor specific for detecting pre-diabetes; fasting glucose is specific but not sensitive. Interventions in people classified through screening as having pre-diabetes have some efficacy in preventing or delaying onset of type 2 diabetes in trial populations. As screening is inaccurate, many people will receives an incorrect diagnosis and be referred on for interventions while others will be falsely reassured and not offered the intervention. These findings suggest that "screen and treat" policies alone are unlikely to have substantial impact on the worsening epidemic of type 2 diabetes.  PROSPERO (No CRD42016042920). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Cost Implications of Using Different ECG Criteria for Screening Young Athletes in the United Kingdom.

    PubMed

    Dhutia, Harshil; Malhotra, Aneil; Gabus, Vincent; Merghani, Ahmed; Finocchiaro, Gherardo; Millar, Lynne; Narain, Rajay; Papadakis, Michael; Naci, Huseyin; Tome, Maite; Sharma, Sanjay

    2016-08-16

    High false-positive rates and cost of additional investigations are an obstacle to electrocardiographic (ECG) screening of young athletes for cardiac disease. However, ECG screening costs have never been systematically assessed in a large cohort of athletes. This study investigated the costs of ECG screening in athletes according to the 2010 European Society of Cardiology (ESC) recommendations and the Seattle and refined interpretation criteria. Between 2011 and 2014, 4,925 previously unscreened athletes aged 14 to 35 years were prospectively evaluated with history, physical examination, and ECG (interpreted with the 2010 ESC recommendations). Athletes with abnormal results underwent secondary investigations, the costs of which were based on U.K. National Health Service Tariffs. The impact on cost after applying the Seattle and refined criteria was evaluated retrospectively. Overall, 1,072 (21.8%) athletes had an abnormal ECG on the basis of 2010 ESC recommendations; 11.2% required echocardiography, 1.7% exercise stress test, 1.2% Holter, 1.2% cardiac magnetic resonance imaging, and 0.4% other tests. The Seattle and refined criteria reduced the number of positive ECGs to 6.0% and 4.3%, respectively. Fifteen (0.3%) athletes were diagnosed with potentially serious cardiac disease using all 3 criteria. The overall cost of de novo screening using 2010 ESC recommendations was $539,888 ($110 per athlete and $35,993 per serious diagnosis). The Seattle and refined criteria reduced the cost to $92 and $87 per athlete screened and $30,251 and $28,510 per serious diagnosis, respectively. Contemporary ECG interpretation criteria decrease costs for de novo screening of athletes, which may be cost permissive for some sporting organizations. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Can the Stockholm convention address the spectrum of chemicals currently under regulatory scrutiny? Advocating a more prominent role for modeling in POP screening assessment.

    PubMed

    McLachlan, Michael S

    2018-01-24

    Frameworks for chemical regulation are based on the science at the time they were written. Today some regulations are being applied to a much broader spectrum of chemicals than we had knowledge of when the regulations were written. This entails a risk that the regulations are being used outside of their chemical application domain. This question is explored using the POP screening assessment in the Stockholm convention, which was developed 20 years ago. Using perfluorinated alkyl acids (PFAAs) as an example, it is shown that the assessment can lead to false negative conclusions. A second case study using octamethylcyclotetrasiloxane (D4) illustrates that there is also a risk of false positives. The risk for false negative classification of PFAAs is due to the inclusion of a screening criterion - bioaccumulation - that is not a requirement for adverse effects of chemicals in remote regions. For D4 the risk of false positive classification stems from the four screening criteria (persistence, bioaccumulation, long-range transport, and adverse effects) applying to different environmental media/compartments. The major lesson is that applying the POP screening procedure to the broad spectrum of chemicals in modern commerce will require that we rely less on the individual screening criteria and more on the comparison of estimated exposure and the thresholds for effects stipulated in Annex D, paragraph 2 of the convention. Models have an important role to play in this context and should become more strongly integrated into the POP screening process.

  9. Results of newborn screening for hearing loss: effects on the family in the first 2 years of life.

    PubMed

    Vohr, Betty R; Jodoin-Krauzyk, Julie; Tucker, Richard; Johnson, Mary Jane; Topol, Deborah; Ahlgren, Marianne

    2008-03-01

    To determine whether there was increased stress and impact on the family for mothers of infants whose screening results and subsequent diagnostic findings indicated hearing loss (HL) and mothers of infants with a positive screening result who subsequently pass the rescreening (false-positive group), compared with mothers of infants who pass the initial screening (control group), when their children were aged 6 to 10, 12 to 16, and 18 to 24 months. Matched cohort analytic study. Home visits. Patients/ Mothers of 33 infants with confirmed HL, 42 infants with a false-positive screening result, and 70 infants in the control group. Screening for HL. Scores on the Parenting Stress Index and the Impact on Family-Adapted Version G. Mothers of infants in the false-positive group did not report increased stress or impact. Mothers of infants with HL reported greater financial impact, total impact, and caretaker burden compared with mothers of infants in the control group. In multivariate analysis of the total cohort, the presence of HL was associated with increased total impact on the family; a neonatal intensive care unit stay was associated with increased stress and total impact on the family; and older maternal age and greater family resources were associated with decreased stress and total impact on the family. Although a false-positive result or a pass of the screening for HL was not associated with increased stress or impact, identification of HL was independently associated with greater total impact on the family when the child was 18 to 24 months of age.

  10. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    PubMed

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPR false-positive rate (P = .011) and CDR cancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPR false-positive rate , sensitivity, and CDR cancer detection rate at all annual interpretive volumes. These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow.

  11. Enhanced HTS hit selection via a local hit rate analysis.

    PubMed

    Posner, Bruce A; Xi, Hualin; Mills, James E J

    2009-10-01

    The postprocessing of high-throughput screening (HTS) results is complicated by the occurrence of false positives (inactive compounds misidentified as active by the primary screen) and false negatives (active compounds misidentified as inactive by the primary screen). An activity cutoff is frequently used to select "active" compounds from HTS data; however, this approach is insensitive to both false positives and false negatives. An alternative method that can minimize the occurrence of these artifacts will increase the efficiency of hit selection and therefore lead discovery. In this work, rather than merely using the activity of a given compound, we look at the presence and absence of activity among all compounds in its "chemical space neighborhood" to give a degree of confidence in its activity. We demonstrate that this local hit rate (LHR) analysis method outperforms hit selection based on ranking by primary screen activity values across ten diverse high throughput screens, spanning both cell-based and biochemical assay formats of varying biology and robustness. On average, the local hit rate analysis method was approximately 2.3-fold and approximately 1.3-fold more effective in identifying active compounds and active chemical series, respectively, than selection based on primary activity alone. Moreover, when applied to finding false negatives, this method was 2.3-fold better than ranking by primary activity alone. In most cases, novel hit series were identified that would have otherwise been missed. Additional uses of and observations regarding this HTS analysis approach are also discussed.

  12. 28 CFR 97.11 - Pre-employment screening.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Pre-employment screening. 97.11 Section... PROVIDING PRISONER OR DETAINEE SERVICES § 97.11 Pre-employment screening. Private prisoner transport companies must adopt pre-employment screening measures for all potential employees. The pre-employment...

  13. 28 CFR 97.11 - Pre-employment screening.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Pre-employment screening. 97.11 Section... PROVIDING PRISONER OR DETAINEE SERVICES § 97.11 Pre-employment screening. Private prisoner transport companies must adopt pre-employment screening measures for all potential employees. The pre-employment...

  14. 28 CFR 97.11 - Pre-employment screening.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Pre-employment screening. 97.11 Section... PROVIDING PRISONER OR DETAINEE SERVICES § 97.11 Pre-employment screening. Private prisoner transport companies must adopt pre-employment screening measures for all potential employees. The pre-employment...

  15. 28 CFR 97.11 - Pre-employment screening.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Pre-employment screening. 97.11 Section... PROVIDING PRISONER OR DETAINEE SERVICES § 97.11 Pre-employment screening. Private prisoner transport companies must adopt pre-employment screening measures for all potential employees. The pre-employment...

  16. [Systematic detection of physical child abuse at emergency rooms].

    PubMed

    Sittig, J S; Uiterwaal, C S P M; Moons, K G M; Russel, I M B; Nievelstein, R A J; Nieuwenhuis, E E S; van de Putte, E M

    2016-01-01

    The aim of our diagnostic accuracy study Child Abuse Inventory at Emergency Rooms (CHAIN-ER) was to establish whether a widely used checklist accurately detects or excludes physical abuse among children presenting to ERs with physical injury. A large multicentre study with a 6-month follow-up in 4 ERs in The Netherlands. Participants were 4290 children aged 0-7 years, attending the ER because of physical injury. All children were systematically tested with an easy-to-use child abuse checklist (index test). A national expert panel (reference standard) retrospectively assessed all children with positive screens and a 15% random sample of the children with negative screens for physical abuse, using additional information, namely, an injury history taken by a paediatrician, information provided by the general practitioner, youth doctor and social services by structured questionnaires, and 6-month follow-up information. Our main outcome measure was physical child abuse; secondary outcome measure was injury due to neglect and need for help. 4253/4290 (99%) parents agreed to follow-up. At a prevalence of 0.07% (3/4253) for inflicted injury by expert panel decision, the positive predictive value of the checklist was 0.03 (95% CI 0.006 to 0.085), and the negative predictive value 1.0 (0.994 to 1.0). There was 100% (93 to 100) agreement about inflicted injury in children, with positive screens between the expert panel and child abuse experts. Rare cases of inflicted injury among preschool children presenting at ERs for injury are very likely captured by easy-to-use checklists, but at very high false-positive rates. Subsequent assessment by child abuse experts can be safely restricted to children with positive screens at very low risk of missing cases of inflicted injury. Because of the high false positive rate, we do advise careful prior consideration of cost-effectiveness and clinical and societal implications before de novo implementation.

  17. Potential of near-infrared hyperspectral reflectance imaging for screening of farm feed contamination

    NASA Astrophysics Data System (ADS)

    Wang, Wenbo; Paliwal, Jitendra

    2005-09-01

    With the outbreak of Bovine Spongiform Encephalopathy (BSE) (commonly known as mad cow disease) in 1987 in the United Kingdom and a recent case discovered in Alberta, more and more emphasis is placed on food and farm feed quality and safety issues internationally. The disease is believed to be spread through farm feed contamination by animal byproducts in the form of meat-and-bone-meal (MBM). The paper reviewed the available techniques necessary to the enforcement of legislation concerning the feed safety issues. The standard microscopy method, although highly sensitive, is laborious and costly. A method to routinely screen farm feed contamination certainly helps to reduce the complexity of safety inspection. A hyperspectral imaging system working in the near-infrared wavelength region of 1100-1600 nm was used to study the possibility of detection of ground broiler feed contamination by ground pork. Hyperspectral images of raw broiler feed, ground broiler feed, ground pork, and contaminated feed samples were acquired. Raw broiler feed samples were found to possess comparatively large spectral variations due to light scattering effect. Ground feed adulterated with 1%, 3%, 5%, and 10% of ground pork was tested to identify feed contamination. Discriminant analysis using Mahalanobis distance showed that the model trained using pure ground feed samples and pure ground pork samples resulted in 100% false negative errors for all test replicates of contaminated samples. A discriminant model trained with pure ground feed samples and 10% contamination level samples resulted in 12.5% false positive error and 0% false negative error.

  18. COLLABORATIVE MODELING OF THE BENEFITS AND HARMS ASSOCIATED WITH DIFFERENT U.S. BREAST CANCER SCREENING STRATEGIES

    PubMed Central

    Mandelblatt, Jeanne S.; Stout, Natasha K.; Schechter, Clyde B.; van den Broek, Jeroen J.; Miglioretti, Diana; Krapcho, Martin; Trentham-Dietz, Amy; Munoz, Diego; Lee, Sandra J.; Berry, Donald A.; van Ravesteyn, Nicolien T.; Alagoz, Oguzhan; Kerlikowske, Karla; Tosteson, Anna N.A.; Near, Aimee M.; Hoeffken, Amanda; Chang, Yaojen; Heijnsdijk, Eveline A.; Chisholm, Gary; Huang, Xuelin; Huang, Hui; Ergun, Mehmet Ali; Gangnon, Ronald; Sprague, Brian L.; Plevritis, Sylvia; Feuer, Eric; de Koning, Harry J.; Cronin, Kathleen A.

    2016-01-01

    Background Controversy persists about optimal mammography screening strategies. Objective To evaluate mammography strategies considering screening and treatment advances. Design Collaboration of six simulation models. Data Sources National data on incidence, risk, breast density, digital mammography performance, treatment effects, and other-cause mortality. Target Population An average-risk cohort. Time Horizon Lifetime. Perspective Societal. Interventions Mammograms from age 40, 45 or 50 to 74 at annual or biennial intervals, or annually from 40 or 45 to 49 then biennially to 74, assuming 100% screening and treatment adherence. Outcome Measures Screening benefits (vs. no screening) include percent breast cancer mortality reduction, deaths averted, and life-years gained. Harms include number of mammograms, false-positives, benign biopsies, and overdiagnosis. Results for Average-Risk Women Biennial strategies maintain 79.8%-81.3% (range across strategies and models: 68.3–98.9%) of annual screening benefits with almost half the false-positives and fewer overdiagnoses. Screening biennially from ages 50–74 achieves a median 25.8% (range: 24.1%-31.8%) breast cancer mortality reduction; annual screening from ages 40–74 years reduces mortality an additional 12.0% (range: 5.7%-17.2%) vs. no screening, but yields 1988 more false-positives and 7 more overdiagnoses per 1000 women screened. Annual screening from ages 50–74 had similar benefits as other strategies but more harms, so would not be recommended. Sub-population Results Annual screening starting at age 40 for women who have a two- to four-fold increase in risk has a similar balance of harms and benefits as biennial screening of average-risk women from 50–74. Limitations We do not consider other imaging technologies, polygenic risk, or non-adherence. Conclusion These results suggest that biennial screening is efficient for average-risk groups, but decisions on strategies depend on the weight given to the balance of harms and benefits. Primary Funding Source National Institutes of Health PMID:26756606

  19. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test

    PubMed Central

    Ortiz, Daniel A.

    2017-01-01

    ABSTRACT A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing (n = 231). The results from the RPR-reactive samples (n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. PMID:28878003

  20. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    PubMed

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  1. Comparison of Six Automated Treponema-Specific Antibody Assays.

    PubMed

    Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk

    2016-01-01

    Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  2. Evaluation of a direct high-capacity target screening approach for urine drug testing using liquid chromatography-time-of-flight mass spectrometry.

    PubMed

    Saleh, Aljona; Stephanson, Niclas Nikolai; Granelli, Ingrid; Villén, Tomas; Beck, Olof

    2012-11-15

    In this study a rapid liquid chromatography-time-of-flight mass spectrometry method was developed, validated and applied in order to evaluate the potential of this technique for routine urine drug testing. Approximately 800 authentic patient samples were analyzed for amphetamines (amphetamine and methamphetamine), opiates (morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine and codeine-6-glucuronide) and buprenorphines (buprenorphine and buprenorphine-glucuronide) using immunochemical screening assays and mass spectrometry confirmation methods for comparison. The chromatographic application utilized a rapid gradient with high flow and a reversed phase column with 1.8 μm particles. Total analysis time was 4 min. The mass spectrometer operated with an electrospray interface in positive mode with a resolution power of >10,000 at m/z 956. The applied reporting limits were 100 ng/mL for amphetamines and opiates, and 5 ng/mL for buprenorphines, with lower limits of quantification were 2.8-41 ng/mL. Calibration curves showed a linear response with coefficients of correlation of 0.97-0.99. The intra- and interday imprecision in quantification at the reporting limits were <10% for all analytes but for buprenorphines <20%. Method validation data met performance criteria for a qualitative and quantitative method. The liquid chromatography-time-of-flight mass spectrometry method was found to be more selective than the immunochemical method by producing lower rates of false positives (0% for amphetamines and opiates; 3.2% for buprenorphines) and negatives (1.8% for amphetamines; 0.6% for opiates; 0% for buprenorphines). The overall agreement between the two screening methods was between 94.2 and 97.4%. Comparison of data with the confirmation (LC-MS) results for all individual 9 analytes showed that most deviating results were produced in samples with low levels of analytes. False negatives were mainly related to failure of detected peak to meet mass accuracy criteria (±20 mDa). False positives was related to presence of interfering peaks meeting mass accuracy and retention time criteria and occurred mainly at low levels. It is concluded that liquid chromatography-time-of-flight mass spectrometry has potential both as a complement and as replacement of immunochemical screening assays. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Informative priors on fetal fraction increase power of the noninvasive prenatal screen.

    PubMed

    Xu, Hanli; Wang, Shaowei; Ma, Lin-Lin; Huang, Shuai; Liang, Lin; Liu, Qian; Liu, Yang-Yang; Liu, Ke-Di; Tan, Ze-Min; Ban, Hao; Guan, Yongtao; Lu, Zuhong

    2017-11-09

    PurposeNoninvasive prenatal screening (NIPS) sequences a mixture of the maternal and fetal cell-free DNA. Fetal trisomy can be detected by examining chromosomal dosages estimated from sequencing reads. The traditional method uses the Z-test, which compares a subject against a set of euploid controls, where the information of fetal fraction is not fully utilized. Here we present a Bayesian method that leverages informative priors on the fetal fraction.MethodOur Bayesian method combines the Z-test likelihood and informative priors of the fetal fraction, which are learned from the sex chromosomes, to compute Bayes factors. Bayesian framework can account for nongenetic risk factors through the prior odds, and our method can report individual positive/negative predictive values.ResultsOur Bayesian method has more power than the Z-test method. We analyzed 3,405 NIPS samples and spotted at least 9 (of 51) possible Z-test false positives.ConclusionBayesian NIPS is more powerful than the Z-test method, is able to account for nongenetic risk factors through prior odds, and can report individual positive/negative predictive values.Genetics in Medicine advance online publication, 9 November 2017; doi:10.1038/gim.2017.186.

  4. Controlling false-negative errors in microarray differential expression analysis: a PRIM approach.

    PubMed

    Cole, Steve W; Galic, Zoran; Zack, Jerome A

    2003-09-22

    Theoretical considerations suggest that current microarray screening algorithms may fail to detect many true differences in gene expression (Type II analytic errors). We assessed 'false negative' error rates in differential expression analyses by conventional linear statistical models (e.g. t-test), microarray-adapted variants (e.g. SAM, Cyber-T), and a novel strategy based on hold-out cross-validation. The latter approach employs the machine-learning algorithm Patient Rule Induction Method (PRIM) to infer minimum thresholds for reliable change in gene expression from Boolean conjunctions of fold-induction and raw fluorescence measurements. Monte Carlo analyses based on four empirical data sets show that conventional statistical models and their microarray-adapted variants overlook more than 50% of genes showing significant up-regulation. Conjoint PRIM prediction rules recover approximately twice as many differentially expressed transcripts while maintaining strong control over false-positive (Type I) errors. As a result, experimental replication rates increase and total analytic error rates decline. RT-PCR studies confirm that gene inductions detected by PRIM but overlooked by other methods represent true changes in mRNA levels. PRIM-based conjoint inference rules thus represent an improved strategy for high-sensitivity screening of DNA microarrays. Freestanding JAVA application at http://microarray.crump.ucla.edu/focus

  5. Newborn Hearing Screening and Early Diagnostic in the NICU

    PubMed Central

    Colella-Santos, Maria Francisca; Hein, Thaís Antonelli Diniz; de Souza, Gabriele Libano; do Amaral, Maria Isabel Ramos; Casali, Raquel Leme

    2014-01-01

    The aim was to describe the outcome of neonatal hearing screening (NHS) and audiological diagnosis in neonates in the NICU. The sample was divided into Group I: neonates who underwent NHS in one step and Group II: neonates who underwent a test and retest NHS. NHS procedure was automated auditory brainstem response. NHS was performed in 82.1% of surviving neonates. For GI, referral rate was 18.6% and false-positive was 62.2% (normal hearing in the diagnostic stage). In GII, with retest, referral rate dropped to 4.1% and false-positive to 12.5%. Sensorineural hearing loss was found in 13.2% of infants and conductive in 26.4% of cases. There was one case of auditory neuropathy spectrum (1.9%). Dropout rate in whole process was 21.7% for GI and 24.03% for GII. We concluded that it was not possible to perform universal NHS in the studied sample or, in many cases, to apply it within the first month of life. Retest reduced failure and false-positive rate and did not increase evasion, indicating that it is a recommendable step in NHS programs in the NICU. The incidence of hearing loss was 2.9%, considering sensorineural hearing loss (0.91%), conductive (1.83%) and auditory neuropathy spectrum (0.19%). PMID:24999481

  6. Hormone replacement therapy and false positive recall in the Million Women Study: patterns of use, hormonal constituents and consistency of effect

    PubMed Central

    Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta

    2006-01-01

    Introduction Current and recent users of hormone replacement therapy (HRT) have an increased risk of being recalled to assessment at mammography without breast cancer being diagnosed ('false positive recall'), but there is limited information on the effects of different patterns of HRT use on this. The aim of this study is to investigate in detail the relationship between patterns of use of HRT and false positive recall. Methods A total of 87,967 postmenopausal women aged 50 to 64 years attending routine breast cancer screening at 10 UK National Health Service Breast Screening Units from 1996 to 1998 joined the Million Women Study by completing a questionnaire before screening and were followed for their screening outcome. Results Overall, 399 (0.5%) participants were diagnosed with breast cancer and 2,629 (3.0%) had false positive recall. Compared to never users of HRT, the adjusted relative risk (95% CI) of false positive recall was: 1.62 (1.43–1.83), 1.80 (1.62–2.01) and 0.76 (0.52–1.10) in current users of oestrogen-only HRT, oestrogen-progestagen HRT and tibolone, respectively (p (heterogeneity) < 0.0001); 1.65 (1.43–1.91), 1.49 (1.22–1.81) and 2.11 (1.45–3.07) for current HRT used orally, transdermally or via an implant, respectively (p (heterogeneity) = 0.2); and 1.84 (1.67–2.04) and 1.75 (1.49–2.06) for sequential and continuous oestrogen-progestagen HRT, respectively (p (heterogeneity) = 0.6). The relative risk of false positive recall among current users appeared to increase with increasing time since menopause, but did not vary significantly according to any other factors examined, including duration of use, hormonal constituents, dose, whether single- or two-view screening was used, or the woman's personal characteristics. Conclusion Current use of oestrogen-only and oestrogen-progestagen HRT, but not tibolone, increases the risk of false positive recall at screening. PMID:16417651

  7. 49 CFR 1544.207 - Screening of individuals and property.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... screening using TSA employees or when using companies under contract with TSA. (c) Aircraft operator... conducting screening using government employees or when using companies under contract with the government. ... 49 Transportation 9 2010-10-01 2010-10-01 false Screening of individuals and property. 1544.207...

  8. 49 CFR 1544.203 - Acceptance and screening of checked baggage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Acceptance and screening of checked baggage. 1544... SECURITY: AIR CARRIERS AND COMMERCIAL OPERATORS Operations § 1544.203 Acceptance and screening of checked... its authorized aircraft operator representative. (c) Screening of checked baggage. Except as provided...

  9. Identification of protein and genetic biomarkers of prostate cancer and risk factors for progression of disease — EDRN Public Portal

    Cancer.gov

    Purpose/Objectives To collect biological samples from subjects with prostate cancer to improve the accuracy of screening tests, identify markers that will predict how aggressive prostate cancers can be, and provide accurate information about how rapidly prostate cancer can worsen. Research Design/Plan Men with the following criteria will be consented for this protocol. 1.) ≥5 years post prostate cancer diagnosis, between the ages of 30 and 99 years of age (OR). (Targeted recruits.) 2.) Diagnosed with prostate cancer with a Gleason’s score ≥ 4+3=7, or 3+3 with survivorship of 5 years, or is positive for metastatic disease, or recurrence or has an unexplained increase in their serum PSA after treatment. (Targeted recruits.) 3.) Diagnosed with prostate cancer in the past in whom follow-up is available. Diagnostic and prognostic data will be collected as well as approximately 2 tablespoons of blood samples will be drawn from a vein in the subjects arm for processing and storage in the GU Tissue Bank (“Tissue Bank and Data Base for Urologic Diseases” HSC20050234H). The study involves a single visit with annual telephone follow-up interviews to update the treatment and prognostic data. Methods Potential subjects will be identified through recruitment at clinics, through advertisement, at prostate cancer lectures, support group meetings, and by referral. Once a potential subject has been identified, they will be informed about the study and the inclusion criteria to see if they qualify. If the subject qualifies and provides informed consent, the study staff will collect and record demographic and disease information and completion of the AUA questionnaire. The subjects will be called annually to updates by the research staff. Clinical Relevance Cancer statistics from the early 1990s reflect both a decline in prostate cancer mortality and a “downstaging” of the disease at the time of diagnosis. Thus, the number of men who have metastases at the time of diagnosis of their initial diagnosis of prostate cancer has decreased in parallel with a decline in mortality. These favorable statistical trends followed the introduction of prostate specific antigen (PSA) as a screening assay for prostate cancer in the late 1980s and imply that earlier diagnosis and treatment provide benefit to the population. However, large scale screening activity must be carefully scrutinized for less desirable outcomes such as “over diagnosis” of biologically indolent disease and failure to diagnose aggressive disease. When screening techniques are introduced into large populations, the number of false positives and false negatives is quite high even when the specificity of a test approaches 95%. Men who are “false positives” needlessly undergo biopsy and the associated anxiety. The detection rate using PSA alone is approximately 25%. The information gained from this study may potentially increase the sensitivity and specificity of prostate cancer screenings, eliminate many of the false negatives and help detect early relapse of disease.

  10. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings.

    PubMed

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-04-01

    Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated by microcalcification detection algorithms. We aim at reducing the number of obvious false-positive findings by adding an additional step in the detection method. In this step, a multiclass machine learning method is implemented in which dedicated classifiers learn to recognize the patterns of obvious false-positive subtypes that occur most frequently. The method is compared to a conventional two-class approach, where all false-positive subtypes are grouped together in one class, and to the baseline CADe system without the new false-positive removal step. The methods are evaluated on an independent dataset containing 1,542 screening examinations of which 80 examinations contain malignant microcalcifications. Analysis showed that the multiclass approach yielded a significantly higher sensitivity compared to the other two methods (P < 0.0002). At one obvious false positive per 100 images, the baseline CADe system detected 61% of the malignant examinations, while the systems with the two-class and multiclass false-positive reduction step detected 73% and 83%, respectively. Our study showed that by adding the proposed method to a CADe system, the number of obvious false positives can decrease significantly (P < 0.0002). © 2017 American Association of Physicists in Medicine.

  11. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    PubMed

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  12. Barriers to postpartum screening for type 2 diabetes: a qualitative study of women with previous gestational diabetes

    PubMed Central

    Rafii, Forough; Rahimparvar, Seyedeh Fatemeh Vasegh; Mehrdad, Neda; Keramat, Afsaneh

    2017-01-01

    Introduction Risk of developing type 2 diabetes is increased in women with previous gestational diabetes mellitus (GDM). Postpartum glycemic screening is recommended in women with recent GDM. But this screening rate is low and the reasons are unclear. The aim of this study was to explore the experiences of Iranian women with recent GDM on barriers of postpartum screening for diabetes. Methods This qualitative study was conducted in Tehran, Iran in 2016. Semi-structured interview was used for data collection. 22 women with recent GDM were interviewed. These women gave birth in Tehran hospitals at a minimum of 6 months before interview. The missed screening defined as not attending to laboratory for Fasting Blood Sugar and/or Oral Glucose Tolerance Test, 6 week to 6 month after their child birthing. The data was analyzed by content analysis method. Results Themes and sub-themes that illustrated the barriers to postpartum diabetes screening were: inadequate education (about developing diabetes in the future, implementation of the screening, and glucometer validity in diagnosis of diabetes), perceiving the screening as difficult (feeling comfortable with the glucometer, poor laboratory conditions, issues related to the baby/babies, and financial problems), improper attitudes toward the screening (unwilling to get diagnosed, not giving priority to oneself, having false beliefs) and procrastination (gap to intention and action, self-deception and self-regulation failure). Conclusion Women with recent GDM reported several barriers for postpartum diabetes screening. This study help to develop the evidence-based interventions for improving this screening rate. PMID:28451031

  13. 42 CFR 455.452 - Other State screening methods.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Other State screening methods. 455.452 Section 455....452 Other State screening methods. Nothing in this subpart must restrict the State Medicaid agency from establishing provider screening methods in addition to or more stringent than those required by...

  14. 42 CFR 455.452 - Other State screening methods.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Other State screening methods. 455.452 Section 455....452 Other State screening methods. Nothing in this subpart must restrict the State Medicaid agency from establishing provider screening methods in addition to or more stringent than those required by...

  15. 46 CFR 108.215 - Insect screens.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Insect screens. 108.215 Section 108.215 Shipping COAST... Construction and Arrangement Accommodation Spaces § 108.215 Insect screens. (a) Accommodation spaces must be protected against the admission of insects. (b) Insect screens must be installed when natural ventilation is...

  16. 49 CFR 1546.201 - Acceptance and screening of individuals and accessible property.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Acceptance and screening of individuals and... FOREIGN AIR CARRIER SECURITY Operations § 1546.201 Acceptance and screening of individuals and accessible... or accessible property before boarding an aircraft or entering a sterile area. (b) Screening of...

  17. 49 CFR 1546.207 - Screening of individuals and property.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TSA is conducting screening using TSA employees or when using companies under contract with TSA. (c... 49 Transportation 9 2010-10-01 2010-10-01 false Screening of individuals and property. 1546.207... SECURITY Operations § 1546.207 Screening of individuals and property. (a) Applicability of this section...

  18. 46 CFR 108.215 - Insect screens.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Insect screens. 108.215 Section 108.215 Shipping COAST... Construction and Arrangement Accommodation Spaces § 108.215 Insect screens. (a) Accommodation spaces must be protected against the admission of insects. (b) Insect screens must be installed when natural ventilation is...

  19. Developments in SPR Fragment Screening.

    PubMed

    Chavanieu, Alain; Pugnière, Martine

    2016-01-01

    Fragment-based approaches have played an increasing role alongside high-throughput screening in drug discovery for 15 years. The label-free biosensor technology based on surface plasmon resonance (SPR) is now sensitive and informative enough to serve during primary screens and validation steps. In this review, the authors discuss the role of SPR in fragment screening. After a brief description of the underlying principles of the technique and main device developments, they evaluate the advantages and adaptations of SPR for fragment-based drug discovery. SPR can also be applied to challenging targets such as membrane receptors and enzymes. The high-level of immobilization of the protein target and its stability are key points for a relevant screening that can be optimized using oriented immobilized proteins and regenerable sensors. Furthermore, to decrease the rate of false negatives, a selectivity test may be performed in parallel on the main target bearing the binding site mutated or blocked with a low-off-rate ligand. Fragment-based drug design, integrated in a rational workflow led by SPR, will thus have a predominant role for the next wave of drug discovery which could be greatly enhanced by new improvements in SPR devices.

  20. Breast screening using 2D-mammography or integrating digital breast tomosynthesis (3D-mammography) for single-reading or double-reading--evidence to guide future screening strategies.

    PubMed

    Houssami, Nehmat; Macaskill, Petra; Bernardi, Daniela; Caumo, Francesca; Pellegrini, Marco; Brunelli, Silvia; Tuttobene, Paola; Bricolo, Paola; Fantò, Carmine; Valentini, Marvi; Ciatto, Stefano

    2014-07-01

    We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial. STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up. For each screen-reading strategy we calculated the number of detected and non-detected (including interval) cancers, cancer detection rates (CDRs), false positive recall (FPR) measures and incremental CDR relative to a comparator strategy. We estimated the false:true positive (FP:TP) ratio and sensitivity of each mammography screening strategy. Paired binary data were compared using McNemar's test. Amongst 7292 screening participants, there were 65 (including six interval) breast cancers; estimated first-year interval cancer rate was 0.82/1000 screens (95% confidence interval (CI): 0.30-1.79/1000). For single-reading, 35 cancers were detected at both 2D and 2D/3D-mammography, 20 cancers were detected only with 2D/3D-mammography compared with none at 2D-mammography alone (p<0.001) and 10 cancers were not detected. For double-reading, 39 cancers were detected at 2D-mammography and 2D/3D-mammography, 20 were detected only with 2D/3D-mammography compared with none detected at 2D-mammography alone (p<0.001) and six cancers were not detected. The incremental CDR attributable to 2D/3D-mammography (versus 2D-mammography) of 2.7/1000 screens (95% CI: 1.6-4.2) was evident for single and for double-reading. Incremental CDR attributable to double-reading (versus single-reading) of 0.55/1000 screens (95% CI: -0.02-1.4) was evident for 2D-mammography and for 2D/3D-mammography. Estimated FP:TP ratios showed that 2D/3D-mammography screening strategies had more favourable FP to TP trade-off and higher sensitivity, applying single-reading or double-reading, relative to 2D-mammography screening. The evidence we report warrants rethinking of breast screening strategies and should be used to inform future evaluations of 2D/3D-mammography that assess whether or not the estimated incremental detection translates into improved screening outcomes such as a reduction in interval cancer rates. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Quality Control Test for Sequence-Phenotype Assignments

    PubMed Central

    Ortiz, Maria Teresa Lara; Rosario, Pablo Benjamín Leon; Luna-Nevarez, Pablo; Gamez, Alba Savin; Martínez-del Campo, Ana; Del Rio, Gabriel

    2015-01-01

    Relating a gene mutation to a phenotype is a common task in different disciplines such as protein biochemistry. In this endeavour, it is common to find false relationships arising from mutations introduced by cells that may be depurated using a phenotypic assay; yet, such phenotypic assays may introduce additional false relationships arising from experimental errors. Here we introduce the use of high-throughput DNA sequencers and statistical analysis aimed to identify incorrect DNA sequence-phenotype assignments and observed that 10–20% of these false assignments are expected in large screenings aimed to identify critical residues for protein function. We further show that this level of incorrect DNA sequence-phenotype assignments may significantly alter our understanding about the structure-function relationship of proteins. We have made available an implementation of our method at http://bis.ifc.unam.mx/en/software/chispas. PMID:25700273

  2. A Danish diabetes risk score for targeted screening: the Inter99 study.

    PubMed

    Glümer, Charlotte; Carstensen, Bendix; Sandbaek, Annelli; Lauritzen, Torsten; Jørgensen, Torben; Borch-Johnsen, Knut

    2004-03-01

    To develop a simple self-administered questionnaire identifying individuals with undiagnosed diabetes with a sensitivity of 75% and minimizing the high-risk group needing subsequent testing. A population-based sample (Inter99 study) of 6,784 individuals aged 30-60 years completed a questionnaire on diabetes-related symptoms and risk factors. The participants underwent an oral glucose tolerance test. The risk score was derived from the first half and validated on the second half of the study population. External validation was performed based on the Danish Anglo-Danish-Dutch Study of Intensive Treatment in People with Screen Detected Diabetes in Primary Care (ADDITION) pilot study. The risk score was developed by stepwise backward multiple logistic regression. The final risk score included age, sex, BMI, known hypertension, physical activity at leisure time, and family history of diabetes, items independently and significantly (P<0.05) associated with the presence of previously undiagnosed diabetes. The area under the receiver operating curve was 0.804 (95% CI 0.765-0.838) for the first half of the Inter99 population, 0.761 (0.720-0.803) for the second half of the Inter99 population, and 0.803 (0.721-0.876) for the ADDITION pilot study. The sensitivity, specificity, and percentage that needed subsequent testing were 76, 72, and 29%, respectively. The false-negative individuals in the risk score had a lower absolute risk of ischemic heart disease compared with the true-positive individuals (11.3 vs. 20.4%; P<0.0001). We developed a questionnaire to be used in a stepwise screening strategy for type 2 diabetes, decreasing the numbers of subsequent tests and thereby possibly minimizing the economical and personal costs of the screening strategy.

  3. Pap smear in the prevention of HPV-related anal cancer: preliminary results of the study in a male population at risk.

    PubMed

    Pisano, Luigi; Tiradritti, Luana; Lorenzoni, Elisa; Zuccati, Giuliano; Matucci, Marzia; Butera, Daniela; Foxi, Prassede; Confortini, Massimo

    2016-12-01

    The aim of this work was to evaluate the role of human papillomavirus (HPV) testing and anal cytology, considering a population of HIV-positive and negative men who have sex with men (MSM), at high risk of sexually transmitted diseases (STD), in order to ascertain which of the methods examined is the best screening strategy for the prevention of anal cancer. In the period 06/2013-07/2014 at the "MTS Centre" of the University of Florence, 87 male patients, homo/bi-sexual, of which 46 HIV-negative and 41 HIV-positive, were recruited for anal Pap smear and HPV testing. All patients with an "abnormal" cytological result underwent anoscopy with possible biopsy. HPV testing was positive in 73 patients (83.6%). Cytology was negative in 50 patients (57.5%), inconclusive in 14 patients (16.1%), abnormal in 23 patients (26.4%): 14 ASC-US (19.2%), 4 ASC-H (5.5%), 5 L-SIL (6.8%), 0 H-SIL. Anoscopy with biopsy led to diagnosis of AIN I in 10 cases, of which 6 ASC-US+ and 4L-SIL+, AIN II in only 1 case, LS-IL+. Anal HPV testing, when used in primary screening, lead to a high number of "false positives", given the too high prevalence of HPV infection in MSM, the highest risk population targeted for screening. So we propose a screening program with anal cytology which has a high sensitivity for detection of AIN while is a poor predictor of the severity of these lesions; therefore, all patients with abnormal anal Pap smear should undergo anoscopy with biopsy.

  4. Spinal ultrasound in patients with anorectal malformations: is this the end of an era?

    PubMed

    Scottoni, Federico; Iacobelli, Barbara Daniela; Zaccara, Antonio Maria; Totonelli, Giorgia; Schingo, Antonio Maria Salvatore; Bagolan, Pietro

    2014-08-01

    Even if lumbar magnetic resonance imaging (MRI) is considered the gold standard in the diagnosis of occult spinal dysraphism (SD) in patients with anorectal malformations (ARMs), spinal ultrasound (US) performed up to 5 months of life have been largely used as a screening test. The aim of the present study was to evaluate the accuracy in terms of sensibility and specificity of neonatal US to detect occult SD in patients with ARMs. Retrospective analysis of all patients treated for ARMs between 1999 and 2013 at our institution who underwent both spinal US (up to 5 months of life) and MRI. Sensibility and specificity have been calculated for US based on MRI results. Of 244 patients treated for ARMs at our institution, 82 (34 females, 48 males) underwent both the imaging studies and have been included in this study. ARMs types were: anal stenosis (7), recto-vestibular fistula (19), recto-perineal fistula (3) and cloaca (5) in female and imperforate anus (7) recto-perineal fistula (14), recto-urethral fistula (22), recto-vesical fistula (5) in males. Forty-seven patients (57, 3 % of total, 18 females, 29 males) had some occult SD (tethered spinal cord, spinal lipoma, syringomyelia) at MRI. Only 7 (14, 8 %) patients of those with spinal anomalies at MRI had pathological US studies. In our population, sensibility and specificity of US for diagnosis of occult SD were, respectively, 14, 8 and 100 %. Since it is well known that a screening test must have a high sensibility, our data suggest that spinal ultrasound is not suitable as a screening test for occult spinal dysraphism in patients with ARMs. Furthermore, we strongly advise against the use of US as a screening test for spinal dysraphism to prevent a false sense of security in physician and patients' families.

  5. Clinical Features of Children With Autism Who Passed 18-Month Screening.

    PubMed

    Øien, Roald A; Schjølberg, Synnve; Volkmar, Fred R; Shic, Frederick; Cicchetti, Domenic V; Nordahl-Hansen, Anders; Stenberg, Nina; Hornig, Mady; Havdahl, Alexandra; Øyen, Anne-Siri; Ventola, Pamela; Susser, Ezra S; Eisemann, Martin R; Chawarska, Katarzyna

    2018-06-01

    We compared sex-stratified developmental and temperamental profiles at 18 months in children screening negative for autism spectrum disorder (ASD) on the Modified Checklist for Autism in Toddlers (M-CHAT) but later receiving diagnoses of ASD (false-negative group) versus those without later ASD diagnoses (true-negative group). We included 68 197 screen-negative cases from the Norwegian Mother and Child Cohort Study (49.1% girls). Children were screened by using the 6 critical items of the M-CHAT at 18 months. Groups were compared on domains of the Ages and Stages Questionnaire and the Emotionality Activity Sociability Temperament Survey. Despite passing M-CHAT screening at 18 months, children in the false-negative group exhibited delays in social, communication, and motor skills compared with the true-negative group. Differences were more pronounced in girls. However, with regard to shyness, boys in the false-negative group were rated as more shy than their true-negative counterparts, but girls in the false-negative group were rated as less shy than their counterparts in the true-negative group. This is the first study to reveal that children who pass M-CHAT screening at 18 months and are later diagnosed with ASD exhibit delays in core social and communication areas as well as fine motor skills at 18 months. Differences appeared to be more pronounced in girls. With these findings, we underscore the need to enhance the understanding of early markers of ASD in boys and girls, as well as factors affecting parental report on early delays and abnormalities, to improve the sensitivity of screening instruments. Copyright © 2018 by the American Academy of Pediatrics.

  6. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.

    2017-02-01

    The goal of this testing was to evaluate the ability of currently available commercial off-the-shelf (COTS) biological indicator tests and immunoassays to detect Bacillus anthracis (Ba) spores and ricin. In general, immunoassays provide more specific identification of biological threats as compared to indicator tests [3]. Many of these detection products are widely used by first responders and other end users. In most cases, performance data for these instruments are supplied directly from the manufacturer, but have not been verified by an external, independent assessment [1]. Our test plan modules included assessments of inclusivity (ability to generate true positive results), commonlymore » encountered hoax powders (which can cause potential interferences or false positives), and estimation of limit of detection (LOD) (sensitivity) testing.« less

  7. A safe and effective management strategy for blunt cerebrovascular injury: Avoiding unnecessary anticoagulation and eliminating stroke.

    PubMed

    Shahan, Charles P; Magnotti, Louis J; Stickley, Shaun M; Weinberg, Jordan A; Hendrick, Leah E; Uhlmann, Rebecca A; Schroeppel, Thomas J; Hoit, Daniel A; Croce, Martin A; Fabian, Timothy C

    2016-06-01

    Few injuries have produced as much debate with respect to management as have blunt cerebrovascular injuries (BCVIs). Recent work (American Association for the Surgery of Trauma 2013) from our institution suggested that 64-channel multidetector computed tomographic angiography (CTA) could be the primary screening tool for BCVI. Consequently, our screening algorithm changed from digital subtraction angiography (DSA) to CTA, with DSA reserved for definitive diagnosis of BCVI following CTA-positive study results or unexplained neurologic findings. The current study was performed to evaluate outcomes, including the potential for missed clinically significant BCVI, since this new management algorithm was adopted. Patients who underwent DSA (positive CTA finding or unexplained neurologic finding) over an 18-month period subsequent to the previous study were identified. Screening and confirmatory test results, complications, and BCVI-related strokes were reviewed and compared. A total of 228 patients underwent DSA: 64% were male, with mean age and Injury Severity Score (ISS) of 43 years and 22, respectively. A total of 189 patients (83%) had a positive screening CTA result. Of these, DSA confirmed injury in 104 patients (55%); the remaining 85 patients (45%) (false-positive results) were found to have no injury on DSA. Five patients (4.8%) experienced BCVI-related strokes, unchanged from the previous study (3.9%, p = 0.756); two were symptomatic at trauma center presentation, and three occurred while receiving appropriate therapy. No patient with a negative screening CTA result experienced a stroke. This management scheme using 64-channel CTA for screening coupled with DSA for definitive diagnosis was proven to be safe and effective in identifying clinically significant BCVIs and maintaining a low stroke rate. Definitive diagnosis by DSA led to avoidance of potentially harmful anticoagulation in 45% of CTA-positive patients (false-positive results). No strokes resulted from injuries missed by CTA. Diagnostic study, level III.

  8. Automatic detection of anomalies in screening mammograms

    PubMed Central

    2013-01-01

    Background Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%. PMID:24330643

  9. Screening drug-induced arrhythmia [corrected] using human induced pluripotent stem cell-derived cardiomyocytes and low-impedance microelectrode arrays.

    PubMed

    Navarrete, Enrique G; Liang, Ping; Lan, Feng; Sanchez-Freire, Verónica; Simmons, Chelsey; Gong, Tingyu; Sharma, Arun; Burridge, Paul W; Patlolla, Bhagat; Lee, Andrew S; Wu, Haodi; Beygui, Ramin E; Wu, Sean M; Robbins, Robert C; Bers, Donald M; Wu, Joseph C

    2013-09-10

    Drug-induced arrhythmia is one of the most common causes of drug development failure and withdrawal from market. This study tested whether human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) combined with a low-impedance microelectrode array (MEA) system could improve on industry-standard preclinical cardiotoxicity screening methods, identify the effects of well-characterized drugs, and elucidate underlying risk factors for drug-induced arrhythmia. hiPSC-CMs may be advantageous over immortalized cell lines because they possess similar functional characteristics as primary human cardiomyocytes and can be generated in unlimited quantities. Pharmacological responses of beating embryoid bodies exposed to a comprehensive panel of drugs at 65 to 95 days postinduction were determined. Responses of hiPSC-CMs to drugs were qualitatively and quantitatively consistent with the reported drug effects in literature. Torsadogenic hERG blockers, such as sotalol and quinidine, produced statistically and physiologically significant effects, consistent with patch-clamp studies, on human embryonic stem cell-derived cardiomyocytes hESC-CMs. False-negative and false-positive hERG blockers were identified accurately. Consistent with published studies using animal models, early afterdepolarizations and ectopic beats were observed in 33% and 40% of embryoid bodies treated with sotalol and quinidine, respectively, compared with negligible early afterdepolarizations and ectopic beats in untreated controls. We found that drug-induced arrhythmias can be recapitulated in hiPSC-CMs and documented with low impedance MEA. Our data indicate that the MEA/hiPSC-CM assay is a sensitive, robust, and efficient platform for testing drug effectiveness and for arrhythmia screening. This system may hold great potential for reducing drug development costs and may provide significant advantages over current industry standard assays that use immortalized cell lines or animal models.

  10. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study

    PubMed Central

    Shimelis, Techalew; Tadesse, Endale

    2015-01-01

    Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677

  11. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study.

    PubMed

    Shimelis, Techalew; Tadesse, Endale

    2015-04-23

    To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Diagnostic accuracy of rapid urine dipstick test to predict urinary tract infection among pregnant women in Felege Hiwot Referral Hospital, Bahir Dar, North West Ethiopia.

    PubMed

    Demilie, Tazebew; Beyene, Getenet; Melaku, Selabat; Tsegaye, Wondewosen

    2014-07-29

    Untreated bacteriuria during pregnancy has been shown to be associated with low birth-weight and premature delivery. Therefore, routine screening for bacteriuria is advocated. The decision about how to screen pregnant women for bacteriuria has always been a balance between the cost of screening versus the sensitivity and specificity. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy against the gold standard urine culture. A total of 367 mid stream urine samples were collected, inoculated on MacConkey, Manitol salt agar (MSA) and blood agar and incubated aerobically at 37°C for overnight. Specimens were classified as "positive" for urinary tract infection (UTI) if the growth of the pathogen(s) was at a count ≥ 10(5) colony-forming units per milliliter (cfu/mL) of urine and classified as "negative" with growth of <10(5) cfu/mL. Urine samples were tested for the presence of nitrite and leukocyte esterase using dipstick rapid test in accordance to the manufacturer's instructions. From the total study participants, 37 pregnant women were symptomatic and the remaining 330 pregnant women were asymptomatic. The sensitivity and specificity of dipstick tests of leukocyte esterase was 50% and 89.1% for pregnant women with asymptomatic UTI(ABU) and 71.4% and 86.7% for symptomatic UTI respectively and for nitrite 35.7% and 98.0% for ABU and 57.1% and 96.7% symptomatic UTI. This study revealed that the use of dipstick leukocyte esterase and nitrite for screening UTI particularly asymptomatic bacteriuria was associated with many false positive and negative results when it was compared against the gold standard culture method. The low sensitivity and positive predictive value of urine dipstick test proved that culture should be used for the diagnosis of UTI.

  13. The essential roles of chemistry in high-throughput screening triage

    PubMed Central

    Dahlin, Jayme L; Walters, Michael A

    2015-01-01

    It is increasingly clear that academic high-throughput screening (HTS) and virtual HTS triage suffers from a lack of scientists trained in the art and science of early drug discovery chemistry. Many recent publications report the discovery of compounds by screening that are most likely artifacts or promiscuous bioactive compounds, and these results are not placed into the context of previous studies. For HTS to be most successful, it is our contention that there must exist an early partnership between biologists and medicinal chemists. Their combined skill sets are necessary to design robust assays and efficient workflows that will weed out assay artifacts, false positives, promiscuous bioactive compounds and intractable screening hits, efforts that ultimately give projects a better chance at identifying truly useful chemical matter. Expertise in medicinal chemistry, cheminformatics and purification sciences (analytical chemistry) can enhance the post-HTS triage process by quickly removing these problematic chemotypes from consideration, while simultaneously prioritizing the more promising chemical matter for follow-up testing. It is only when biologists and chemists collaborate effectively that HTS can manifest its full promise. PMID:25163000

  14. Harms of Breast Cancer Screening: Systematic Review to Update the 2009 U.S. Preventive Services Task Force Recommendation.

    PubMed

    Nelson, Heidi D; Pappas, Miranda; Cantor, Amy; Griffin, Jessica; Daeges, Monica; Humphrey, Linda

    2016-02-16

    In 2009, the U.S. Preventive Services Task Force recommended biennial mammography screening for women aged 50 to 74 years and selective screening for those aged 40 to 49 years. To review studies of screening in average-risk women with mammography, magnetic resonance imaging, or ultrasonography that reported on false-positive results, overdiagnosis, anxiety, pain, and radiation exposure. MEDLINE and Cochrane databases through December 2014. English-language systematic reviews, randomized trials, and observational studies of screening. Investigators extracted and confirmed data from studies and dual-rated study quality. Discrepancies were resolved through consensus. Based on 2 studies of U.S. data, 10-year cumulative rates of false-positive mammography results and biopsies were higher with annual than biennial screening (61% vs. 42% and 7% vs. 5%, respectively) and for women aged 40 to 49 years, those with dense breasts, and those using combination hormone therapy. Twenty-nine studies using different methods reported overdiagnosis rates of 0% to 54%; rates from randomized trials were 11% to 22%. Women with false-positive results reported more anxiety, distress, and breast cancer-specific worry, although results varied across 80 observational studies. Thirty-nine observational studies indicated that some women reported pain during mammography (1% to 77%); of these, 11% to 46% declined future screening. Models estimated 2 to 11 screening-related deaths from radiation-induced cancer per 100,000 women using digital mammography, depending on age and screening interval. Five observational studies of tomosynthesis and mammography indicated increased biopsies but reduced recalls compared with mammography alone. Studies of overdiagnosis were highly heterogeneous, and estimates varied depending on the analytic approach. Studies of anxiety and pain used different outcome measures. Radiation exposure was based on models. False-positive results are common and are higher for annual screening, younger women, and women with dense breasts. Although overdiagnosis, anxiety, pain, and radiation exposure may cause harm, their effects on individual women are difficult to estimate and vary widely. Agency for Healthcare Research and Quality.

  15. Hepatitis C Virus: Patients' Risk Factors and Knowledge in an Urban Clinic Providing Wound Care.

    PubMed

    Pieper, Barbara; Sickon, Katharine

    2018-03-01

    Affecting about 3.2 million people in the United States, hepatitis C virus (HCV) is the primary cause of chronic liver disease and a global health challenge. Hepatitis C virus can affect the functioning of the liver, the health of the person, and thus wound healing. This quality project explores risk factors of HCV; self-reported screening, occurrence, and treatment; and knowledge of HCV in patients seeking wound care in an urban clinic. Demographic risk factors, HCV history, and responses to a 22-item true-false-don't know HCV Knowledge Test were obtained from 58 patients. Risk factors included age (mean, 61.07 years), male sex (n = 41), non-Hispanic black race/ethnicity (n = 51), and history of injection drugs (n = 38). Thirty-nine (67.2%) stated they had been screened for HCV; 31 were told they were infected. Only 14 went to a clinic for HCV care and 11 reported they were treated. The mean number of correct answers on the HCV Knowledge Test was 14.4 (standard deviation, 5.7). This urban clinic had patients with multiple HCV risk factors; they often lacked HCV screening and/or referral for treatment. Their HCV knowledge was generally low. As a major public health problem that could impact wound healing, wound care practitioners should ask patients about their HCV status, encourage HCV screening and care, and provide HCV information.

  16. 48 CFR 245.608 - Screening of contractor inventory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Screening of contractor inventory. 245.608 Section 245.608 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS... Disposal of Contractor Inventory 245.608 Screening of contractor inventory. ...

  17. Consensus review of discordant findings maximizes cancer detection rate in double-reader screening mammography: Irish National Breast Screening Program experience.

    PubMed

    Shaw, Colette M; Flanagan, Fidema L; Fenlon, Helen M; McNicholas, Michelle M

    2009-02-01

    To assesses consensus review of discordant screening mammography findings in terms of its sensitivity, safety, and effect on overall performance in the first 6 years of operation of the Irish National Breast Screening Program (NBSP). Women who participated in the Irish NBSP gave written informed consent for use of their data for auditing purposes. Local ethics committee approval was obtained. The study population consisted of women who participated in the Irish NBSP and underwent initial screening mammography at one of the two screening centers serving the eastern part of Ireland between 2000 and 2005. Independent double reading of mammograms was performed. When the readers disagreed regarding referral, the case was reviewed by a consensus panel. Of the 128 569 screenings performed, 1335 (1%) were discussed by consensus. Of the 1335 cases discussed by consensus, 606 (45.39%) were recalled for further assessment. This resulted in an overall recall rate of 4.41%. In those recalled to assessment, 71 cases of malignant disease were diagnosed (ductal carcinoma in situ, n = 24; invasive cancer, n = 47). The remaining 729 patients were returned to biennial screening. Of these 729 patients, seven had false-negative findings that were identified in the subsequent screening round. Use of the highest reader recall method, in which a patient is recalled if her findings are deemed abnormal by either reader, could potentially increase the cancer detection rate by 0.6 per 1000 women screened but would increase the recall rate by 12.69% and the number of false-positive findings by 15.37%. The consensus panel identified 71 (7.33%) of 968 cancers diagnosed. Consensus review substantially reduced the number of cases recalled and was associated with a low false-negative rate.

  18. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.

  19. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices

    NASA Astrophysics Data System (ADS)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.

  20. Emphysema and soluble CD14 are associated with pulmonary nodules in HIV-infected patients: implications for lung cancer screening.

    PubMed

    Triplette, Matthew; Sigel, Keith M; Morris, Alison; Shahrir, Shahida; Wisnivesky, Juan P; Kong, Chung Y; Diaz, Phillip T; Petraglia, Alycia; Crothers, Kristina

    2017-07-31

    Lung cancer screening may benefit HIV-infected (HIV) smokers because of an elevated risk of lung cancer, but may have unique harms because of HIV-specific risk factors for false-positive screens. This study seeks to understand whether inflammatory biomarkers and markers of chronic lung disease are associated with noncalcified nodules at least 4 mm (NCN) in HIV compared with uninfected patients. This is a cohort study of Examinations of HIV-Associated Lung Emphysema (EXHALE), including 158 HIV and 133 HIV-uninfected participants. Participants underwent a laboratory assessment [including measurement of D-dimer, interleukin 6, and soluble CD14 (sCD14)], chest computed tomography (CT), and pulmonary function testing. We created multivariable logistic regression models to determine predictors of NCN in the participants stratified by HIV status, with attention to semiqualitative scoring of radiographic emphysema, markers of pulmonary function, and inflammatory biomarkers. Of the 291 participants, 69 had NCN on chest CT. As previously reported, there was no difference in prevalence of these nodules by HIV status. Emphysema and elevated sCD14 demonstrated an association with NCN in HIV participants independent of smoking status, CD4 cell count, HIV viral load, and pulmonary function. Emphysema and sCD14, a marker of immune activation, was associated with a higher prevalence of NCN on chest CT in HIV participants. Patients with chronic immune activation and emphysema may be at higher risk for both false-positive findings and incident lung cancer, thus screening in this group requires further study to understand the balance of benefits and harms.

  1. Factors affecting reproducibility between genome-scale siRNA-based screens

    PubMed Central

    Barrows, Nicholas J.; Le Sommer, Caroline; Garcia-Blanco, Mariano A.; Pearson, James L.

    2011-01-01

    RNA interference-based screening is a powerful new genomic technology which addresses gene function en masse. To evaluate factors influencing hit list composition and reproducibility, we performed two identically designed small interfering RNA (siRNA)-based, whole genome screens for host factors supporting yellow fever virus infection. These screens represent two separate experiments completed five months apart and allow the direct assessment of the reproducibility of a given siRNA technology when performed in the same environment. Candidate hit lists generated by sum rank, median absolute deviation, z-score, and strictly standardized mean difference were compared within and between whole genome screens. Application of these analysis methodologies within a single screening dataset using a fixed threshold equivalent to a p-value ≤ 0.001 resulted in hit lists ranging from 82 to 1,140 members and highlighted the tremendous impact analysis methodology has on hit list composition. Intra- and inter-screen reproducibility was significantly influenced by the analysis methodology and ranged from 32% to 99%. This study also highlighted the power of testing at least two independent siRNAs for each gene product in primary screens. To facilitate validation we conclude by suggesting methods to reduce false discovery at the primary screening stage. In this study we present the first comprehensive comparison of multiple analysis strategies, and demonstrate the impact of the analysis methodology on the composition of the “hit list”. Therefore, we propose that the entire dataset derived from functional genome-scale screens, especially if publicly funded, should be made available as is done with data derived from gene expression and genome-wide association studies. PMID:20625183

  2. Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off.

    PubMed

    Schütz, Harald; Auch, Jürgen; Erdmann, Freidoon; Weiler, Günter; Verhoff, Marcel A

    2006-01-01

    Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.

  3. Summary of the evidence of breast cancer service screening outcomes in Europe and first estimate of the benefit and harm balance sheet.

    PubMed

    Paci, Eugenio

    2012-01-01

    To construct a European 'balance sheet' of key outcomes of population-based mammographic breast cancer screening, to inform policy-makers, stakeholders and invited women. From the studies reviewed, the primary benefit of screening, breast cancer mortality reduction, was compared with the main harms, over-diagnosis and false-positive screening results (FPRs). Pooled estimates of breast cancer mortality reduction among invited women were 25% in incidence-based mortality studies and 31% in case-control studies (38% and 48% among women actually screened). Estimates of over-diagnosis ranged from 1% to 10% of the expected incidence in the absence of screening. The combined estimate of over-diagnosis for screened women, from European studies correctly adjusted for lead time and underlying trend, was 6.5%. For women undergoing 10 biennial screening tests, the estimated cumulative risk of a FPR followed by non-invasive assessment was 17%, and 3% having an invasive assessment. For every 1000 women screened biennially from age 50-51 until age 68-69 and followed up to age 79, an estimated seven to nine lives are saved, four cases are over-diagnosed, 170 women have at least one recall followed by non-invasive assessment with a negative result and 30 women have at least one recall followed by invasive procedures yielding a negative result. The chance of saving a woman's life by population-based mammographic screening of appropriate quality is greater than that of over-diagnosis. Service screening in Europe achieves a mortality benefit at least as great as the randomized controlled trials. These outcomes should be communicated to women offered service screening in Europe.

  4. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    PubMed

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  5. 7 CFR 58.228 - Dump hoppers, screens, mixers and conveyors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Dump hoppers, screens, mixers and conveyors. 58.228... Service 1 Equipment and Utensils § 58.228 Dump hoppers, screens, mixers and conveyors. The product contact surfaces of dump hoppers, screens, mixers and conveyors which are used in the process of transferring dry...

  6. 28 CFR 115.81 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Medical and mental health screenings; history of sexual abuse. 115.81 Section 115.81 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... Care § 115.81 Medical and mental health screenings; history of sexual abuse. (a) If the screening...

  7. 28 CFR 115.381 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Medical and mental health screenings; history of sexual abuse. 115.381 Section 115.381 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... § 115.381 Medical and mental health screenings; history of sexual abuse. (a) If the screening pursuant...

  8. 28 CFR 115.81 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Medical and mental health screenings; history of sexual abuse. 115.81 Section 115.81 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... Care § 115.81 Medical and mental health screenings; history of sexual abuse. (a) If the screening...

  9. 28 CFR 115.81 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Medical and mental health screenings; history of sexual abuse. 115.81 Section 115.81 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... Care § 115.81 Medical and mental health screenings; history of sexual abuse. (a) If the screening...

  10. 28 CFR 115.381 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Medical and mental health screenings; history of sexual abuse. 115.381 Section 115.381 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... § 115.381 Medical and mental health screenings; history of sexual abuse. (a) If the screening pursuant...

  11. 28 CFR 115.381 - Medical and mental health screenings; history of sexual abuse.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Medical and mental health screenings; history of sexual abuse. 115.381 Section 115.381 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED... § 115.381 Medical and mental health screenings; history of sexual abuse. (a) If the screening pursuant...

  12. Screening for Latent Tuberculosis in the Patient With Moderate to Severe Psoriasis Who Is a Candidate for Systemic and/or Biologic Therapy.

    PubMed

    Martínez-López, A; Rodriguez-Granger, J; Ruiz-Villaverde, R

    2016-04-01

    Screening to detect latent tuberculosis infection (LTBI) is essential before patients with moderate to severe psoriasis start treatment with biologics and vigilance will continue to be needed during and after such treatment. The most recently analyzed statistics from the BIOBADADERM registry show a 20.5% prevalence of LTBI in psoriasis patients treated with biologics in Spain. Various screening protocols are in effect in different countries according to their levels of endemic TB and bacillus Calmette-Guérin (BCG) vaccination, and there is no consensus on a gold-standard approach to the diagnosis of LTBI. Tuberculin skin testing (TST) continues to be the diagnostic method of choice in spite of its limited sensitivity, mainly in immunocompromised patients. Additional problems include the TST's well-established lack of specificity, errors in application, subjectivity in the interpretation of results (which must be read during a second visit), and lack of privacy; the main advantages of this test are its low cost and ease of application. Most cost-benefit studies are therefore inclined to favor using interferon-γ release assays to detect LTBI because they minimize false positives (especially in BCG-vaccinated individuals), thereby eliminating the extra costs and side effects of unnecessary chemoprophylaxis. We review the methods used for LTBI screening in psoriasis patients who are candidates for biologic therapy. Additionally, given the fact that most guidelines do not currently consider it necessary to screen patients about to start conventional systemic therapy, we discuss the reasons underlying the need for such screening. Copyright © 2015 AEDV. Published by Elsevier España, S.L.U. All rights reserved.

  13. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    PubMed

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  14. A new CAD approach for improving efficacy of cancer screening

    NASA Astrophysics Data System (ADS)

    Zheng, Bin; Qian, Wei; Li, Lihua; Pu, Jiantao; Kang, Yan; Lure, Fleming; Tan, Maxine; Qiu, Yuchen

    2015-03-01

    Since performance and clinical utility of current computer-aided detection (CAD) schemes of detecting and classifying soft tissue lesions (e.g., breast masses and lung nodules) is not satisfactory, many researchers in CAD field call for new CAD research ideas and approaches. The purpose of presenting this opinion paper is to share our vision and stimulate more discussions of how to overcome or compensate the limitation of current lesion-detection based CAD schemes in the CAD research community. Since based on our observation that analyzing global image information plays an important role in radiologists' decision making, we hypothesized that using the targeted quantitative image features computed from global images could also provide highly discriminatory power, which are supplementary to the lesion-based information. To test our hypothesis, we recently performed a number of independent studies. Based on our published preliminary study results, we demonstrated that global mammographic image features and background parenchymal enhancement of breast MR images carried useful information to (1) predict near-term breast cancer risk based on negative screening mammograms, (2) distinguish between true- and false-positive recalls in mammography screening examinations, and (3) classify between malignant and benign breast MR examinations. The global case-based CAD scheme only warns a risk level of the cases without cueing a large number of false-positive lesions. It can also be applied to guide lesion-based CAD cueing to reduce false-positives but enhance clinically relevant true-positive cueing. However, before such a new CAD approach is clinically acceptable, more work is needed to optimize not only the scheme performance but also how to integrate with lesion-based CAD schemes in the clinical practice.

  15. Precision and recall estimates for two-hybrid screens

    PubMed Central

    Huang, Hailiang; Bader, Joel S.

    2009-01-01

    Motivation: Yeast two-hybrid screens are an important method to map pairwise protein interactions. This method can generate spurious interactions (false discoveries), and true interactions can be missed (false negatives). Previously, we reported a capture–recapture estimator for bait-specific precision and recall. Here, we present an improved method that better accounts for heterogeneity in bait-specific error rates. Result: For yeast, worm and fly screens, we estimate the overall false discovery rates (FDRs) to be 9.9%, 13.2% and 17.0% and the false negative rates (FNRs) to be 51%, 42% and 28%. Bait-specific FDRs and the estimated protein degrees are then used to identify protein categories that yield more (or fewer) false positive interactions and more (or fewer) interaction partners. While membrane proteins have been suggested to have elevated FDRs, the current analysis suggests that intrinsic membrane proteins may actually have reduced FDRs. Hydrophobicity is positively correlated with decreased error rates and fewer interaction partners. These methods will be useful for future two-hybrid screens, which could use ultra-high-throughput sequencing for deeper sampling of interacting bait–prey pairs. Availability: All software (C source) and datasets are available as supplemental files and at http://www.baderzone.org under the Lesser GPL v. 3 license. Contact: joel.bader@jhu.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:19091773

  16. [Breast cancer screening in Austria: Key figures, age limits, screening intervals and evidence].

    PubMed

    Jeitler, Klaus; Semlitsch, Thomas; Posch, Nicole; Siebenhofer, Andrea; Horvath, Karl

    2015-01-01

    In January 2014, the first nationwide quality-assured breast cancer screening program addressing women aged ≥ 40 years was introduced in Austria. As part of the process of developing a patient information leaflet, the Evidence Based Medicine (EBM) Review Center of the Medical University of Graz was charged with the task of assessing the potential benefits and harms of breast cancer screening from the available evidence. Based on these results, key figures were derived for mortality, false-positive and false-negative mammography results, and overdiagnosis, considering Austria-specific incidence rates for breast cancer and breast cancer mortality. Furthermore, the current evidence regarding age limits and screening interval, which were the subjects of controversial public discussions, was analyzed. A systematic search for primary and secondary literature was performed and additional evidence was screened, e. g., evaluation reports of European breast cancer screening programs. On the basis of the available evidence and of the Austrian breast cancer mortality and incidence rates, it can be assumed that - depending on the age group - 1 to 4 breast cancer deaths can be avoided per 1,000 women screened in a structured breast cancer screening program, while the overall mortality remains unchanged. On the other hand, 150 to 200 of these 1,000 women will be affected by false-positive results and 1 to 9 women by overdiagnosis due to the structured breast cancer screening. Therefore, the overall benefit-harm balance is uncertain. If women from 40 to 44 or above 70 years of age are considered, who can also participate in the Austrian screening program, even a negative benefit-harm balance seems possible. However, with the implementation of quality standards in breast cancer screening and the dissemination of a patient information leaflet, an improvement in the medical treatment situation, specifically in terms of informed decision-making, can be expected. Copyright © 2015. Published by Elsevier GmbH.

  17. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  18. Posture Alignment of Adolescent Idiopathic Scoliosis: Photogrammetry in Scoliosis School Screening.

    PubMed

    Penha, Patrícia Jundi; Penha, Nárima Lívia Jundi; De Carvalho, Bárbarah Kelly Gonçalves; Andrade, Rodrigo Mantelatto; Schmitt, Ana Carolina Basso; João, Sílvia Maria Amado

    The objective of this study was to describe the posture patterns of adolescents diagnosed with adolescent idiopathic scoliosis (AIS) in a scoliosis school screening (SSS). Two-dimensional photogrammetry was used to assess the posture of 37 adolescents diagnosed with scoliosis (scoliosis group, SG) (Cobb angle ≥10°) and 76 adolescents with a false positive diagnosis (false positive group, FPG) (Cobb angle <10°, angle of trunk rotation ≥7°). In total, 2562 10- to 14-year-old adolescents were enrolled in the SSS, which was performed in public schools in the cities of Amparo, Pedreira, and Mogi Mirim in the state of São Paulo, Brazil. Their posture was analyzed using Postural Analysis Software. Continuous variables were tested using Student t test, and categorical variables were tested using a χ2 test. The SG, FPG, simple curve group, and double curve group were all compared. Bivariate analysis was used to identify associations between postural deviations and scoliosis. The adopted significance level was α = .05. The SG (2.7 ± 1.9°) had greater shoulder obliquity than the FPG (1.9 ± 1.4°) (P = .010), and this deviation was associated with scoliosis (odds ratio [95% CI] P = 1.4 [1.1-1.8] 0.011). The SG had asymmetry between the right- and left-side lower limb frontal angle, shoulder sagittal alignment, and knee angle. The double curve group (3 ± 1.7°) presented a greater value of the vertical alignment of the torso than the simple curve group did (1.9 ± 1°; P = .032). Adolescents diagnosed with AIS in an SSS had greater shoulder obliquity and asymmetry between the right and left sides. Shoulder obliquity was the only postural deviation associated with AIS. Copyright © 2017. Published by Elsevier Inc.

  19. Development and experimental test of support vector machines virtual screening method for searching Src inhibitors from large compound libraries

    PubMed Central

    2012-01-01

    Background Src plays various roles in tumour progression, invasion, metastasis, angiogenesis and survival. It is one of the multiple targets of multi-target kinase inhibitors in clinical uses and trials for the treatment of leukemia and other cancers. These successes and appearances of drug resistance in some patients have raised significant interest and efforts in discovering new Src inhibitors. Various in-silico methods have been used in some of these efforts. It is desirable to explore additional in-silico methods, particularly those capable of searching large compound libraries at high yields and reduced false-hit rates. Results We evaluated support vector machines (SVM) as virtual screening tools for searching Src inhibitors from large compound libraries. SVM trained and tested by 1,703 inhibitors and 63,318 putative non-inhibitors correctly identified 93.53%~ 95.01% inhibitors and 99.81%~ 99.90% non-inhibitors in 5-fold cross validation studies. SVM trained by 1,703 inhibitors reported before 2011 and 63,318 putative non-inhibitors correctly identified 70.45% of the 44 inhibitors reported since 2011, and predicted as inhibitors 44,843 (0.33%) of 13.56M PubChem, 1,496 (0.89%) of 168 K MDDR, and 719 (7.73%) of 9,305 MDDR compounds similar to the known inhibitors. Conclusions SVM showed comparable yield and reduced false hit rates in searching large compound libraries compared to the similarity-based and other machine-learning VS methods developed from the same set of training compounds and molecular descriptors. We tested three virtual hits of the same novel scaffold from in-house chemical libraries not reported as Src inhibitor, one of which showed moderate activity. SVM may be potentially explored for searching Src inhibitors from large compound libraries at low false-hit rates. PMID:23173901

  20. Screening for ALK in non-small cell lung carcinomas: 5A4 and D5F3 antibodies perform equally well, but combined use with FISH is recommended.

    PubMed

    Savic, Spasenija; Diebold, Joachim; Zimmermann, Anne-Katrin; Jochum, Wolfram; Baschiera, Betty; Grieshaber, Susanne; Tornillo, Luigi; Bisig, Bettina; Kerr, Keith; Bubendorf, Lukas

    2015-08-01

    Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Top