21 CFR 882.4900 - Skullplate screwdriver.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skullplate screwdriver. 882.4900 Section 882.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4900 Skullplate screwdriver. (a...
21 CFR 882.4900 - Skullplate screwdriver.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skullplate screwdriver. 882.4900 Section 882.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4900 Skullplate screwdriver. (a...
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.
NASA Astrophysics Data System (ADS)
Grinevich, I.; Nikishin, Vl.; Mozga, N.; Laitans, M.
2017-06-01
The paper deals with the possibilities of reducing the consumption of electrical energy of the impact screwdriver during the assembly of fixed threaded joints. The recommendations related to a decrease in electrical energy consumption would allow reducing product costs but so far there have been no such recommendations from the producers of the tool as to the effective operating regimes of the impact screwdrivers in relation to electrical energy consumption and necessary tightening moment of the nut. The aim of the study is to find out the economical operating mode of the electrical impact screwdriver when assembling fixed threaded joints. By varying the set speed of the rotor head and working time of the impact mechanism, there is an opportunity to determine electrical energy consumption of the tool for the given tightening moment. The results of the experiment show that at the same tightening moment obtained the electrical energy consumption of the impact screwdriver is less at a higher starting set speed of the rotor head but shorter operating time of the impact mechanism than at a lower speed of the rotor head and longer operating time of the impact mechanism.
Katalinic, Andrej; Trinajstic Zrinski, Magda; Roksandic Vrancic, Zlatka; Spalj, Stjepan
2017-02-01
The study focused on the influence of screwdriver design in combination with and without predrilling a pilot hole of inner implant diameter on insertion torque of orthodontic mini-implants, controlling for cortical thickness and vertical insertion force as cofactors. One hundred twenty mini-implants (Forestadent) of 1.7 mm in diameter and 6 and 8 mm in length were manually inserted into 120 swine rib bone samples. Maximal insertion torque as a measure of primary stability and vertical force were measured. The study included procedures with and without pilot hole and different screwdriver handles and shaft length and 2 implant lengths. Design of manual screwdriver does not modify insertion torque to a significant extent. In multiple linear regression model, significant predictors of insertion torque are thicker cortical bone (explaining 16.6% of variability), higher vertical force at maximal torque (13.5%), 6-mm implant length (2.5%), and the presence of pilot hole (2.3%). Handle type and shaft length of manual screwdriver do not significantly influence insertion torque, whereas predrilling a pilot hole has low impact on torque values of manually inserted self-drilling orthodontic mini-implants.
Brown-Sequard syndrome associated with unusual spinal cord injury by a screwdriver stab wound
Beer-Furlan, André Luiz; Paiva, Wellingson Silva; Tavares, Wagner Malagó; de Andrade, Almir Ferreira; Teixeira, Manoel Jacobsen
2014-01-01
Introduction: Stab wounds resulting in spinal cord injuries are very rare. In direct central back stabbings, the layers of muscles and the spinal column tends to deflect blades, rarely causing injuries to the spinal cord. We report an unusual case of traumatic spinal cord injury by a screwdriver stab, presented as Brown-Séquard syndrome and discuss possible pitfalls on the surgical treatment. Case report: A 34 year-old man was brought to the emergency department after a group assault with a single screwdriver stab wound on the back. Neurological examination revealed an incomplete Brown-Sequard syndrome, with grade IV motor deficit on the left leg and contralateral hemihypoalgesia below T9 level. Radiological evaluation showed a retained 9 cm screwdriver that entered and trespassed the spinal canal at T6 level, reaching the posterior mediastinum with close relation to the thoracic aorta. Vascular injury could not be excluded. The joint decision between the neurosurgery and the vascular surgery teams was the surgical removal of the screwdriver under direct visualization. A left mini-thoracotomy was performed. Simultaneously, a careful dissection was done and screwdriver was firmly pulled back on the opposite path of entry under direct visualization of the aorta. The neurological deficit was maintained immediately after the surgical procedure. Follow-up visit after 1 year showed minor motor deficit and good healing. Conclusions: It is important to consider all aspects of secondary injury on the surgical planning of penetrating spinal cord injury. The secondary injury can be minimized with multidisciplinary planning of the surgical procedure. PMID:24482724
Evaluation of handle design characteristics in a maximum screwdriving torque task.
Kong, Y-K; Lowe, B D; Lee, S-J; Krieg, E F
2007-09-01
The purpose of this study was to evaluate the effects of screwdriver handle shape, surface material and workpiece orientation on torque performance, finger force distribution and muscle activity in a maximum screwdriving torque task. Twelve male subjects performed maximum screw-tightening exertions using screwdriver handles with three longitudinal shapes (circular, hexagonal and triangular), four lateral shapes (cylindrical, double frustum, cone and reversed double frustum) and two surfaces (rubber and plastic). The average finger force contributions to the total hand force were 28.1%, 39.3%, 26.5% and 6.2%, in order from index to little fingers; the average phalangeal segment force contributions were 47.3%, 14.0%, 20.5% and 18.1% for distal, middle, proximal and metacarpal phalanges, respectively. The plastic surface handles were associated with 15% less torque output (4.86 Nm) than the rubber coated handles (5.73 Nm). In general, the vertical workpiece orientation was associated with higher torque output (5.9 Nm) than the horizontal orientation (4.69 Nm). Analysis of handle shapes indicates that screwdrivers designed with a circular or hexagonal cross-sectional shape result in greater torque outputs (5.49 Nm, 5.57 Nm), with less total finger force (95 N, 105 N). In terms of lateral shape, reversed double frustum handles were associated with less torque output (5.23 Nm) than the double frustum (5.44 Nm) and cone (5.37 Nm) handles. Screwdriver handles designed with combinations of circular or hexagonal cross-sectional shapes with double frustum and cone lateral shapes were optimal in this study.
Nam, Seung Min; Kim, Yong Bae; Cha, Han Gyu; Wee, Syeo Young; Choi, Chang Yong
2015-09-01
The management of subcondylar mandibular fractures has been a matter of controversy. Although closed reduction is the most useful method, it can be difficult to achieve anatomical reduction with this technique compared with open reduction and internal fixation (ORIF). Most surgeons prefer to treat subcondylar fractures by extraoral approaches rather than intraoral approaches because extraoral approaches provide good visualization of the operative field. The retromandibular, submandibular, and perilobular approaches are commonly performed in the treatment of displaced condylar or subcondylar fractures and that the functional results of these treatments are good. However, extraoral approaches have a high rate of surgical complications such as salivary fistula formation, visible scarring, and facial nerve injury, compared with intraoral approaches. Therefore, this clinical study evaluated the clinical results of ORIF for mandibular subcondylar fractures through a transoral approach using an angulated screwdriver system without endoscopic assistance. A study was conducted between March 2011 and October 2012. Eleven patients with subcondylar fractures of the mandible were treated through a transoral approach using an angulated screwdriver. There were 10 male patients and 1 female patient aged 21 to 72 years (mean, 38 years). Nine patients had a symphyseal or parasymphyseal fracture, and 2 patients had isolated subcondylar fractures of the mandible. Eleven patients with subcondylar fractures of the mandible were treated with a transoral approach using an angulated screwdriver. The subcondylar fracture was on the left side in 6 patients and on the right in 5. All patients achieved satisfactory ranges of temporomandibular joint movement with an interincisal distance of more than 40 mm without deviation and stable individual centric occlusion. The maximum operation duration was 165 minutes, and the average duration of ORIF was 97 minutes. The association between the operation duration and the number of operations was statistically significant. Our clinical study shows that subcondylar fractures of the mandible can be treated using an angulated screwdriver system through a transoral approach and that this technique provides reliable, satisfactory, and safe clinical outcomes.
Combined tool approach is 100% successful for emergency football face mask removal.
Copeland, Aaron J; Decoster, Laura C; Swartz, Erik E; Gattie, Eric R; Gale, Stephanie D
2007-11-01
To compare effectiveness of two techniques for removing football face masks: cutting loop straps [cutting tool: FMXtractor (FMX)] or removing screws with a cordless screwdriver and using the FMXtractor as needed for failed removals [combined tool (CT)]. Null hypotheses: no differences in face mask removal success, removal time or difficulty between techniques or helmet characteristics. Retrospective, cross-sectional. NOCSAE-certified helmet reconditioning plants. 600 used high school helmets. Face mask removal attempted with two techniques. Success, removal time, rating of perceived exertion (RPE). Both techniques were effective [CT 100% (300/300); FMX 99.4% (298/300)]. Use of the backup FMXtractor in CT trials was required in 19% of trials. There was significantly (P<0.001) less call for the backup tool in helmets with silver screws (6%) than in helmets with other screws (31%). Mean removal time was 44.51+/-18.79s (CT: 37.84+/-15.37s, FMX: 51.21+/-19.54s; P<0.001). RPE was different between techniques (CT: 1.83+/-1.20, FMX: 3.11+/-1.27; P<0.001). Removal from helmets with silver screws was faster (Silver=33.38+/-11.03, Others=42.18+/-17.64; P<0.001) and easier (Silver=1.42+/-0.89, Other=2.23+/-1.33; P<0.001). CT was faster and easier than FMX. Most CT trials were completed with the screwdriver alone; helmets with silver screws had 94% screwdriver success. Clinically, these findings are important because this and other research shows that compared to removal with cutting tools, screwdriver removal decreases time, difficulty and helmet movement (reducing potential for iatrogenic injury). The combined-tool approach captures benefits of the screwdriver while offering a contingency for screw removal failure. Teams should use degradation-resistant screws. Sports medicine professionals must be prepared with appropriate tools and techniques to efficiently remove the face mask from an injured football player's helmet.
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
Decoster, Laura C; Shirley, Chandra P; Swartz, Erik E
2005-01-01
Context: The Inter-Association Task Force for the Appropriate Care of the Spine-Injured Athlete recommends leaving a football player's helmet in place and removing the face mask from the helmet “as quickly as possible and with as little movement of the head and neck as possible.” Although 2 groups have studied face-mask removal from new equipment, to our knowledge no researchers have investigated equipment that has been previously used. A full season of play may have a significant effect on football equipment and its associated hardware. Countless impacts, weather, playing surfaces, sweat, and other unforeseen or unknown variables might make the face-mask removal process more difficult on equipment that has been used. Objective: To determine the percentage of face masks that we could unscrew, with a cordless screwdriver, from football helmets used for a full season. Design: Cross-sectional. Setting: Three New England high schools. Patients or Other Participants: All football helmets used at 3 local high schools were tested (n = 222, mean games, 9.7 ± 1.2; mean practice weeks, 13.7 ± 1.2). Intervention(s): Each helmet was secured to a board, and a cordless screwdriver was used to attempt to remove all 4 screws attaching the face mask to the helmet. Main Outcome Measure(s): Variables included overall success or failure, time required for face-mask removal, and success by screw location. Data were analyzed with χ2, analysis of variance, and Tamhane post hoc tests. Results: Overall, 832 (94%) of 885 screws were unscrewed, and 183 (82.4%) of 222 face masks were removed. Mean removal time was 26.9 ± 5.83 seconds. Face-mask removal success was significantly different between school 1 (24 [52.2%] of 46) and schools 2 (84 [91.3%] of 92) and 3 (75 [89.3%] of 84; F2,219 = 24.608; P < .001). The removal success rate was significantly higher at top screws (98%) than at screws adjacent to ear holes (90%) (P < .001). Conclusions: Based on our results and previous findings that demonstrated quicker access time and reduced head movement associated with the use of the screwdriver compared with cutting tools, the former may be a good tool for face-mask removal. However, an appropriate cutting tool must be immediately available should the screwdriver fail. Helmet hardware adjacent to ear holes was more vulnerable to failure, perhaps because it is protected by less padding than the top hardware. Possible causes of the higher failure rate at school 1 are the use of hardware materials subject to rust and corrosion and differences in helmet brand; these areas warrant future research and rules consideration. PMID:16284636
1995-10-20
Onboard Space Shuttle Columbia (STS-73) Payload Specialist Albert Sacco loads autoclaves using a power screwdriver into the Zeolite Crystal Growth (ZCG) experiment in the middeck for the United States Microgravity Laboratory 2 (USML-2) Spacelab mission.
29 CFR 1910.268 - Telecommunications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ground line as possible using a pole prod or a screwdriver with a blade at least 5 inches long. If... conducter on the pole (exclusive of vertical runs and street light wiring), except: (i) Where communications...
29 CFR 1910.268 - Telecommunications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... ground line as possible using a pole prod or a screwdriver with a blade at least 5 inches long. If... conducter on the pole (exclusive of vertical runs and street light wiring), except: (i) Where communications...
29 CFR 1910.268 - Telecommunications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ground line as possible using a pole prod or a screwdriver with a blade at least 5 inches long. If... conducter on the pole (exclusive of vertical runs and street light wiring), except: (i) Where communications...
29 CFR 1910.268 - Telecommunications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ground line as possible using a pole prod or a screwdriver with a blade at least 5 inches long. If... conducter on the pole (exclusive of vertical runs and street light wiring), except: (i) Where communications...
29 CFR 1910.268 - Telecommunications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... ground line as possible using a pole prod or a screwdriver with a blade at least 5 inches long. If... conducter on the pole (exclusive of vertical runs and street light wiring), except: (i) Where communications...
NASA Astrophysics Data System (ADS)
Grinevich, I.; Mozga, N.; Rudzitis, J.
2013-10-01
The electrical energy consumption of battery-operated screwdrivers, which are widely used in many industries, e.g. automotive, heavy, chemical, etc., can be considerably reduced. This would allow increasing the service life of a battery and reducing the time of its charging, thus increasing the productivity and decreasing the prime cost of this battery. It is shown that up to 17.9% of electrical energy could be saved at assembling fixed threaded joints by removing power from the screwdriver immediately after reaching the required tightening torque. Dotajā rakstā uzmanība tiek pievērsta akumulatora skrūvgrieža elektroenerģijas patēriņa samazināšanas iespējām sakarā ar problēmas aktualitāti šīs grupas plaši pielietotajiem instrumentiem. Elektroenerģijas patēriņa samazināšana masveida ražošanā, kur tiek izmantoti akumulatora skrūvgrieži, ļautu paildzināt akumulatora baterijas kalpošanas mūžu un samazināt uzlādēšanas laiku, kas, savukārt, novestu pie ražības palielināšanas un produkcijas pašizmaksas samazināšanas.
Virtual Tool Mark Generation for Efficient Striation Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekstrand, Laura; Zhang, Song; Grieve, Taylor
2014-02-16
This study introduces a tool mark analysis approach based upon 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. An open-source 3D graphics software package is utilized to simulate the marking process as the projection of the tip's geometry in the direction of tool travel. The edge of this projection becomes a virtual tool mark that is compared to cross-sections of the marked plate geometry using the statistical likelihood algorithm introduced by Chumbley et al. In a study with both sides of six screwdriver tips and 34 corresponding marks, the method distinguishedmore » known matches from known nonmatches with zero false-positive matches and two false-negative matches. For matches, it could predict the correct marking angle within ±5–10°. Individual comparisons could be made in seconds on a desktop computer, suggesting that the method could save time for examiners.« less
Use of a 90° drill and screwdriver for rib fracture stabilization.
Nickerson, Terry P; Kim, Brian D; Zielinski, Martin D; Jenkins, Donald; Schiller, Henry J
2015-03-01
Rib fracture stabilization has become a more accepted practice although stabilization of the most cephalad ribs presents a unique challenge. We present our experience with use of a 90° drill and screwdriver to bridge these difficult rib fractures. This retrospective review included patients who underwent rib fracture stabilization from August 1, 2009, through September 30, 2012. Patients were divided into two groups: those whose procedure used the 90° device and those that did not. Data were compared using standard statistical analysis and reported as percentages and medians [interquartile ranges]. P values <0.05 were considered significant. We identified 89 patients: 29 (33%) had 90° devices used and 60 (67%) did not. There were no differences between groups in age, sex, Trauma-Related Injury Severity Score, the presence of flail chest, occurrence of pneumonia, and intensive care unit or hospital length of stay. The Injury Severity Score was higher in the 90° group (22 vs. 16; P = 0.03). The highest rib stabilized was different between the 2 groups (3 [2-5] vs. 5 [2-9]; P = 0.001), with more third rib stabilizations in the 90° group (38 vs. 20%; P = 0.04) as well as more total number of ribs fixed (5 vs. 4; P = 0.001). There was no difference in operative time between the 2 groups. The surgical reach for rib fracture stabilization has been extended with use of a 90° drill and screwdriver. High fractures under the scapula where access is technically challenging can be stabilized without prolonging operative times.
Forces associated with pneumatic power screwdriver operation: statics and dynamics.
Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G
2003-10-10
The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders.
Single wrench separates nuts from free-floating bolts
NASA Technical Reports Server (NTRS)
Thompson, C.
1967-01-01
Pneumatic impact wrench removes the nuts from freely turning bolts when the heads cannot be reached or the shafts anchored. It uses a fixed screwdriver blade that fits a slot cut into the threaded end of the bolt shaft.
Power-Tool Adapter For T-Handle Screws
NASA Technical Reports Server (NTRS)
Deloach, Stephen R.
1992-01-01
Proposed adapter enables use of pneumatic drill, electric drill, electric screwdriver, or similar power tool to tighten or loosen T-handled screws. Notched tube with perpendicular rod welded to it inserted in chuck of tool. Notched end of tube slipped over screw handle.
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
NASA Technical Reports Server (NTRS)
Wilcomb, E. F.
1969-01-01
Tool mitten provides a low reaction torque source of power for wrench, screwdriver, or drill activities. The technique employed prevents the attachments from drifting away from the operator. While the tools are specifically designed for space environments, they can be used on steel scaffolding, in high building maintenance, or underwater environments.
Shop Tools. FOS: Fundamentals of Service.
ERIC Educational Resources Information Center
John Deere Co., Moline, IL.
This shop tools manual is one of a series of power mechanics texts and visual aids on servicing of automotive and off-the-road equipment. Materials provide basic information and illustrations for use by vocational students and teachers as well as shop servicemen and laymen. Sections describe the use of the following tools: screwdrivers, hammers,…
[The VB system: a new modular osteosynthesis material involving both screws and wires].
Dubert, T; Valenti, P; Dinh, A; Osman, N
2002-01-01
VB is an osteosynthesis system for the stabilisation of small fragments, which combines the benefits of both wires and screws. It is a modular system comprising a threaded pin and a ring. The threaded pin is first positioned. Then a ring is grasped and opened by the progressive angulation of a screwdriver. Still anchored on the screwdriver, the ring slides easily on the pin. It is clamped on the pin by simply removing the screwdriver and the pin is then cut. This modular system includes 1.8 and 1.1 mm pins and different types of rings (threaded or non threaded, with or without collars). The system is easy to handle and can be introduced using an open or percutaneous technique, allowing compression or distraction. Our preliminary series, performed in accordance with National clinical trial protocol (Huriet) consisted of 50 cases in 24 patients (five women and 19 men) with an average age of 48 years, and a follow-up of more than six months. Fourteen cases of fractures (28 implants) were treated as emergencies (two radial heads, one capitellum, one trochlea of the humerus, seven distal radius fractures, one trapezium, two metacarpals) and 12 cases (22 implants) were elective cases: arthrodesis (one trapezo-metacarpal, one intermetacarpal, two interphalangeal, two carpal), non-union (six scaphoids, one phalangeal) and one phalangeal malunion. Hardware removal was performed in 16 cases. No implant failure has been detected. One case, a DIP arthrodesis, had a suspicion of sepsis which led to the removal of the implants at six weeks. The results of this study have convinced us of the merits of the system, which combines the advantages of both wires and screws. The system allows the user to perform either distraction or compression, and to adjust the force by hand. Compared to the fixed amount of compression produced by lag screws, this feature seems to be a real step forward.
The Combined Tool Approach for Face Mask Removal During On-field Conditions
Gale, Stephanie D; Decoster, Laura C; Swartz, Erik E
2008-01-01
Context: An effective approach to emergency removal of the face mask (FM) from a football helmet should include successful removal of the FM and limitation of both the time required and the movement created during the process. Current recommendations and practice are to use a cutting tool to remove the FM. Researchers recently have suggested an alternate approach that combines the use of a cordless screwdriver and a cutting tool. This combined tool approach has not been studied, and FM removal has not been studied in a practical setting. Objective: To investigate the effectiveness and speed of using a combined tool approach to remove the FMs from football helmets during on-field conditions throughout the course of a football season. Design: Randomized multigroup design. Setting: Practice field of 1 National Collegiate Athletic Association Division II football college. Patients or Other Participants: Eighty-four members of 1 football team. Intervention(s): We used a battery-operated screwdriver for FM removal and resorted to using a cutting tool as needed. Main Outcome Measure(s): We tracked FM removal success and failure and trial time and compared results based on helmet characteristics, weather variables, and the seasonal timing of the removal trial. Results: Of the 84 players, 76 were available for data-collection trials. Overall, 98.6% (75/76) of FM removal trials were successful and resulted in a mean removal time of 40.09 ± 15.1 seconds. We found no differences in FM removal time throughout the course of the season. No differences in effectiveness or trial time were found among helmet characteristics, weather variables, or the timing of the trial. Conclusions: Combining the cordless screwdriver and cutting tool provided a fast and reliable means of on-field FM removal in this Division II setting. Despite the excellent overall result, 1 FM was not removed in a timely manner. Therefore, we recommend that athletic trainers practice helmet removal to be prepared should FM removal fail. PMID:18335008
Plastic Clamp Retains Clevis Pin
NASA Technical Reports Server (NTRS)
Cortes, R. G.
1983-01-01
Plastic clamp requires no special installation or removal tools. Clamp slips easily over end of pin. Once engaged in groove, holds pin securely. Installed and removed easily without special tools - screwdriver or putty knife adequate for prying out of groove. Used to retain bearings, rollers pulleys, other parts that rotate. Applications include slowly and intermittently rotating parts in appliances.
Making Do with What We Have: Use Your Bootstraps
ERIC Educational Resources Information Center
Calmettes, Guillaume; Drummond, Gordon B.; Vowler, Sarah L.
2012-01-01
A jack knife is a pocket knife that is put to many tasks, because it's ready to hand. Often there could be a better tool for the job, such as a screwdriver, a scraper, or a can-opener, but these are not usually pocket items. In statistical terms, the expression implies making do with what's available. Another simile, of an extreme situation, is…
ERIC Educational Resources Information Center
Turnbow, Dominique; Zeidman-Karpinski, Annie
2016-01-01
Instruction librarians want clear data showing the effectiveness of our workshops as a way of demonstrating our value in education. This article uses instructional design approaches to show how to make specific changes when writing and measuring our learning outcomes to capture what we are doing in our sessions. Unlike instructors with classes…
Collette, Cynthia; Bonnotte, Isabelle; Jacquemont, Charlotte; Kalénine, Solène; Bartolo, Angela
2016-01-01
Object semantics include object function and manipulation knowledge. Function knowledge refers to the goal attainable by using an object (e.g., the function of a key is to open or close a door) while manipulation knowledge refers to gestures one has to execute to use an object appropriately (e.g., a key is held between the thumb and the index, inserted into the door lock and then turned). To date, several studies have assessed function and manipulation knowledge in brain lesion patients as well as in healthy adult populations. In patients with left brain damage, a double dissociation between these two types of knowledge has been reported; on the other hand, behavioral studies in healthy adults show that function knowledge is processed faster than manipulation knowledge. Empirical evidence has shown that object interaction in children differs from that in adults, suggesting that the access to function and manipulation knowledge in children might also differ. To investigate the development of object function and manipulation knowledge, 51 typically developing 8-9-10 year-old children and 17 healthy young adults were tested on a naming task associated with a semantic priming paradigm (190-ms SOA; prime duration: 90 ms) in which a series of line drawings of manipulable objects were used. Target objects could be preceded by three priming contexts: related (e.g., knife-scissors for function; key-screwdriver for manipulation), unrelated but visually similar (e.g., glasses-scissors; baseball bat-screwdriver), and purely unrelated (e.g., die-scissors; tissue-screwdriver). Results showed a different developmental pattern of function and manipulation priming effects. Function priming effects were not present in children and emerged only in adults, with faster naming responses for targets preceded by objects sharing the same function. In contrast, manipulation priming effects were already present in 8-year-olds with faster naming responses for targets preceded by objects sharing the same manipulation and these decreased linearly between 8 and 10 years of age, 10-year-olds not differing from adults. Overall, results show that the access to object function and manipulation knowledge changes during development by favoring manipulation knowledge in childhood and function knowledge in adulthood. PMID:27602004
The 6,000 Mile Screwdriver is Getting Longer: Washington’s Strengthening Grip
2012-04-01
OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for... information . Send comments regarding this burden estimate or any other aspect of this collection of information , including suggestions for reducing...this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson
Prosthetic Tool For Holding Small Ferromagnetic Parts
NASA Technical Reports Server (NTRS)
Norton, William E.; Carden, James R.; Belcher, Jewell G., Jr.; Vest, Thomas W.
1995-01-01
Tool attached to prosthetic hand or arm enables user to hold nails, screws, nuts, rivets, and other small ferromagnetic objects on small magnetic tip. Device adjusted to hold nail or screw at proper angle for hammering or for use of screwdriver, respectively. Includes base connector with threaded outer surface and lower male member inserted in standard spring-action, quick-connect/quick-disconnect wrist adapter on prosthetic hand or arm.
NASA Technical Reports Server (NTRS)
1974-01-01
Space technology utilization for developing tools, adapters, and fixtures and procedures for assembling, installing, and servicing electrical components and equipment are discussed. Some of the items considered are: (1) pivotal screwdriver, (2) termination locator tool for shielded cables, (3) solder application tools, (4) insulation and shield removing tool, and (5) torque wrench adapter for cable connector engaging ring. Diagrams of the various tools and devices are provided.
ERIC Educational Resources Information Center
Scopelitis, Stephanie A.
2013-01-01
As human beings, we live "in", live "with", and live "through" our bodies. And because of this it is no wonder that our hands and bodies are in motion as we interact with others in our world. Hands and body move as we give directions to another, anticipate which way to turn the screwdriver, and direct our friend to…
1976-07-30
34 "extracting/loading amunitions "firing hammer" "four life-saving steps" "chest/heart massage " "tourniquet material" "field material" "field condition" "mouth... scarred use carred surface screwdriver van seal (n) I ell e 4,-Aft AD-A121 062 JOB LANGUAGE PERFORMANCE REQUIREMENTS FOR MOS 63G FUEL AND ELECTRICAL
1978-12-01
students (Olson, 1971; Yelo- 6, Schmidt , 1971; Stedman, i970) adds nothing to our knowledge; thec- studies, too, are Plagued I...in a beha.ioral objective for a mathmatics class wtld be "... using only a calculator ...’ or 0... using only the protractor...’ The second are the...pliers, screwdriver and hammer i.1 0.1 3. To write x & y from memory 1.1 0.1 4. To lever press either x or y within two seconds 1.1 0.1 5. To point
Perini, Francesca; Caramazza, Alfonso; Peelen, Marius V.
2014-01-01
Functional neuroimaging studies have implicated the left lateral occipitotemporal cortex (LOTC) in both tool and hand perception but the functional role of this region is not fully known. Here, by using a task manipulation, we tested whether tool-/hand-selective LOTC contributes to the discrimination of tool-associated hand actions. Participants viewed briefly presented pictures of kitchen and garage tools while they performed one of two tasks: in the action task, they judged whether the tool is associated with a hand rotation action (e.g., screwdriver) or a hand squeeze action (e.g., garlic press), while in the location task they judged whether the tool is typically found in the kitchen (e.g., garlic press) or in the garage (e.g., screwdriver). Both tasks were performed on the same stimulus set and were matched for difficulty. Contrasting fMRI responses between these tasks showed stronger activity during the action task than the location task in both tool- and hand-selective LOTC regions, which closely overlapped. No differences were found in nearby object- and motion-selective control regions. Importantly, these findings were confirmed by a TMS study, which showed that effective TMS over the tool-/hand-selective LOTC region significantly slowed responses for tool action discriminations relative to tool location discriminations, with no such difference during sham TMS. We conclude that left LOTC contributes to the discrimination of tool-associated hand actions. PMID:25140142
[Low obstruction tract by system Reemex].
Bujons Tur, A; Errando Smet, C; Prados Saavedra, M; Báez, C; Arañó Bertrán, P; Gutiérrez Ruiz, C; Villavicencio Mavrich, H
2007-01-01
The Remeex system it's a sling with regulable tension created for the surgical correction of the female urinary incontinente. The system contains a varitensor central part of the protesis that regulates the tension of the uretra. The screwdriver that acts against the varitensor to the modify the tension under the uretra in the postop inmediately or time after also. We present a clinic case of a patient with diagnostic of urinary stress incontinence and the surgical treatment with advantages against others kind of systems used for incontinence treatment at this time.
2017-09-01
which is then turned over and pressed by hand against a flat surface. The solder ring is removed from the flange using a flat blade mini screwdriver...densities of M10 propellant. This series of experiments was conducted to get an indication of how many experiments could be run with the same window...While we were able to run 6 experiments with a pair of solder rings as the window seat, we typically replace the seat after 4 experiments have been
Paralimbic system and striatum are involved in motivational behavior.
Nishimura, Masahiko; Yoshii, Yoshihiko; Watanabe, Jobu; Ishiuchi, Shogo
2009-10-28
Goal-directed rewarded behavior and goal-directed non-rewarded behavior are concerned with motivation. However, the neural substrates involved in goal-directed non-rewarded behaviors are unknown. Using functional magnetic resonance imaging, we investigated the brain activities of healthy individuals during a novel tool use (turning a screwdriver) to elucidate the relationship between the brain mechanism relevant to goal-directed non-rewarded behavior and motivation. We found that our designed behavioral task evoked activities in the orbitofrontal cortex, striatum, anterior insula, lateral prefrontal cortex, and anterior cingulate cortex compared with a meaningless task. These results suggest that activation in these cerebral regions play important roles in motivational behavior without tangible rewards.
Franco, E; Hodgson, S; Lench, N; Roberts, G J
1995-03-01
A case of Nance-Horan syndrome in a male is presented, with some features of the condition in his carrier mother and her mother. It is proposed that Nance-Horan syndrome might be a contiguous gene syndrome mapping to chromosome Xp21.2-p22.3. The proband had congenital cataract microphthalmia and dental abnormalities including screwdriver shaped incisors and evidence of enamel pitting hypoplasia. The region Xp21.2-p22.3 also contains the tooth enamel protein gene, amelogenin (AMGX). Using molecular genetic techniques, we have shown that there is no evidence that the AMGX gene is deleted in this case of the Nance-Horan syndrome.
Advanced torque converters for robotics and space applications
NASA Technical Reports Server (NTRS)
1985-01-01
This report describes the results of the evaluation of a novel torque converter concept. Features of the concept include: (1) automatic and rapid adjustment of effective gear ratio in response to changes in external torque (2) maintenance of output torque at zero output velocity without loading the input power source and (3) isolation of input power source from load. Two working models of the concept were fabricated and tested, and a theoretical analysis was performed to determine the limits of performance. It was found that the devices are apparently suited to certain types of tool driver applications, such as screwdrivers, nut drivers and valve actuators. However, quantiative information was insufficient to draw final conclusion as to robotic applications.
Use of a scanning optical profilometer for toolmark characterization
NASA Astrophysics Data System (ADS)
Chumbley, L. S.; Eisenmann, D. J.; Morris, M.; Zhang, S.; Craft, J.; Fisher, C.; Saxton, A.
2009-05-01
An optical profilometer has been used to obtain 3-dimensional data for use in two research projects concerning toolmark quantification and identification. In the first study quantitative comparisons between toolmarks made using data from the optical system proved superior to similar data obtained using a stylus profilometer. In the second study the ability of the instrument to obtain accurate data from two surfaces intersecting at a high angle (approximately 90 degrees) is demonstrated by obtaining measurements from the tip of a flat screwdriver. The data obtained was used to produce a computer generated "virtual tool," which was then employed to create "virtual tool marks." How these experiments were conducted and the results obtained will be presented and discussed.
Development of a Portable Torque Wrench Tester
NASA Astrophysics Data System (ADS)
Wang, Y.; Zhang, Q.; Gou, C.; Su, D.
2018-03-01
A portable torque wrench tester (PTWT) with calibration range from 0.5 Nm to 60 Nm has been developed and evaluated for periodic or on-site calibration of setting type torque wrenches, indicating type torque wrenches and hand torque screwdrivers. The PTWT is easy to carry with weight about 10 kg, simple and efficient operation and energy saving with an automatic loading and calibrating system. The relative expanded uncertainty of torque realized by the PTWT was estimated to be 0.8%, with the coverage factor k=2. A comparison experiment has been done between the PTWT and a reference torque standard at our laboratory. The consistency between these two devices under the claimed uncertainties was verified.
Objective forensic analysis of striated, quasi-striated and impressed toolmarks
NASA Astrophysics Data System (ADS)
Spotts, Ryan E.
Following the 1993 Daubert v. Merrell Dow Pharmaceuticals, Inc. court case and continuing to the 2010 National Academy of Sciences report, comparative forensic toolmark examination has received many challenges to its admissibility in court cases and its scientific foundations. Many of these challenges deal with the subjective nature in determining whether toolmarks are identifiable. This questioning of current identification methods has created a demand for objective methods of identification - "objective" implying known error rates and statistically reliability. The demand for objective methods has resulted in research that created a statistical algorithm capable of comparing toolmarks to determine their statistical similarity, and thus the ability to separate matching and nonmatching toolmarks. This was expanded to the creation of virtual toolmarking (characterization of a tool to predict the toolmark it will create). The statistical algorithm, originally designed for two-dimensional striated toolmarks, had been successfully applied to striated screwdriver and quasi-striated plier toolmarks. Following this success, a blind study was conducted to validate the virtual toolmarking capability using striated screwdriver marks created at various angles of incidence. Work was also performed to optimize the statistical algorithm by implementing means to ensure the algorithm operations were constrained to logical comparison regions (e.g. the opposite ends of two toolmarks do not need to be compared because they do not coincide with each other). This work was performed on quasi-striated shear cut marks made with pliers - a previously tested, more difficult application of the statistical algorithm that could demonstrate the difference in results due to optimization. The final research conducted was performed with pseudostriated impression toolmarks made with chisels. Impression marks, which are more complex than striated marks, were analyzed using the algorithm to separate matching and nonmatching toolmarks. Results of the conducted research are presented as well as evidence of the primary assumption of forensic toolmark examination; all tools can create identifiably unique toolmarks.
Virtual tool mark generation for efficient striation analysis in forensic science
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekstrand, Laura
In 2009, a National Academy of Sciences report called for investigation into the scienti c basis behind tool mark comparisons (National Academy of Sciences, 2009). Answering this call, Chumbley et al. (2010) attempted to prove or disprove the hypothesis that tool marks are unique to a single tool. They developed a statistical algorithm that could, in most cases, discern matching and non-matching tool marks made at di erent angles by sequentially numbered screwdriver tips. Moreover, in the cases where the algorithm misinterpreted a pair of marks, an experienced forensics examiner could discern the correct outcome. While this research served tomore » con rm the basic assumptions behind tool mark analysis, it also suggested that statistical analysis software could help to reduce the examiner's workload. This led to a new tool mark analysis approach, introduced in this thesis, that relies on 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. These scans are carefully cleaned to remove noise from the data acquisition process and assigned a coordinate system that mathematically de nes angles and twists in a natural way. The marking process is then simulated by using a 3D graphics software package to impart rotations to the tip and take the projection of the tip's geometry in the direction of tool travel. The edge of this projection, retrieved from the 3D graphics software, becomes a virtual tool mark. Using this method, virtual marks are made at increments of 5 and compared to a scan of the evidence mark. The previously developed statistical package from Chumbley et al. (2010) performs the comparison, comparing the similarity of the geometry of both marks to the similarity that would occur due to random chance. The resulting statistical measure of the likelihood of the match informs the examiner of the angle of the best matching virtual mark, allowing the examiner to focus his/her mark analysis on a smaller range of angles. Preliminary results are quite promising. In a study with both sides of 6 screwdriver tips and 34 corresponding marks, the method distinguished known matches from known non-matches with zero false positive matches and only two matches mistaken for non-matches. For matches, it could predict the correct marking angle within 5-10 . Moreover, on a standard desktop computer, the virtual marking software is capable of cleaning 3D tip and plate scans in minutes and producing a virtual mark and comparing it to a real mark in seconds. These results support several of the professional conclusions of the tool mark analysis com- munity, including the idea that marks produced by the same tool only match if they are made at similar angles. The method also displays the potential to automate part of the comparison process, freeing the examiner to focus on other tasks, which is important in busy, backlogged crime labs. Finally, the method o ers the unique chance to directly link an evidence mark to the tool that produced it while reducing potential damage to the evidence.« less
Objective analysis of impressed chisel toolmarks
Spotts, Ryan; Chumbley, L. Scott
2015-08-06
Historical and recent challenges to the practice of comparative forensic examination have created a driving force for the formation of objective methods for toolmark identification. In this study, fifty sequentially manufactured chisels were used to create impression toolmarks in lead (500 toolmarks total). An algorithm previously used to statistically separate known matching and nonmatching striated screwdriver marks and quasi-striated plier marks was used to evaluate the chisel marks. Impression toolmarks, a more complex form of toolmark, pose a more difficult test for the algorithm that was originally designed for striated toolmarks. Lastly, results show in this instance that the algorithmmore » can separate matching and nonmatching impression marks, providing further validation of the assumption that toolmarks are identifiably unique.« less
Do Sealing Materials Influence Superstructure Attachment in Implants?
Biscoping, Stephanie; Ruttmann, Esther; Rehmann, Peter; Wöstmann, Bernd
This study aimed to evaluate the possible effect of sealing materials on superstructure attachment (ie, tightening/loosening torque and implant-abutment gap) in two different implant systems. A silicone, a chlorhexidine gel, and an industrial lubricant were tested. A 3D microscope was used for assessment of the implant-abutment gap, and the abutment screw was tightened and loosened with a digital torque screwdriver. A total of 20 implants per test group (10 BEGO Semados RI and 10 Nobel Biocare Replace Select Straight) were evaluated. The tested sealing materials did not influence the gap between implant and abutment, but the force necessary for loosening the abutment screws decreased significantly. Sealing materials may be useful against bacteria, but probably influence torque negatively.
Dental management of patient with Williams Syndrome - A case report.
Wong, Daniel; Ramachandra, Srinivas Sulugodu; Singh, Ashish Kumar
2015-01-01
Williams syndrome is a multisystemic rare genetic disorder caused by deletion of 26-28 genes in the long arm of chromosome 7. It is characterized by developmental and physical abnormalities including congenital cardiovascular abnormalities, mental retardation, neurological features, growth deficiency, genitourinary manifestations, gastrointestinal problems, musculoskeletal problems, unique behavioral characteristics, and dental problems. Dental abnormalities include malocclusion, hypodontia, malformed teeth, taurodontism, pulp stones, increased space between teeth, enamel hypoplasia, and high prevalence of dental caries. Authors report a 17-year-old female patient with underlying Williams syndrome. Oral features and problems seen in the patient are listed. Malocclusion and screwdriver shaped teeth were noticed. Generalized widening of the periodontal ligament space with vital teeth was seen. This finding has not been reported in cases of Williams syndrome earlier. Precautions taken during dental treatment in patients with Williams syndrome are also discussed.
Nance–Horan Syndrome: A Rare Case Report
Sharma, Shambhu; Datta, Pankaj; Sabharwal, Janak Raj; Datta, Sonia
2017-01-01
Dentofacial anomalies may guide us to the diagnosis of many congenital and hereditary syndromes. A 9-year-old boy was diagnosed with Nance–Horan syndrome. This syndrome is an extremely rare X-linked genetic disorder which is entirely expressed in males with semi-dominant transmission which results from mutations occurring in male gametes. It is characterized by facial dysmorphism such as long face, prominent nose and mandibular prognathism, ocular abnormalities such as congenital cataract, microcornea, microphthalmia and strabismus, and dental anomalies including mulberry molars and screwdriver-shaped incisors. Heterozygous females inherit this disease and also suffer from this syndrome but in a milder form. Approximately one-third of the affected males show signs of developmental delay and intellectual abnormalities. This syndrome is very rare and the incidence of the disease has not been established so far. The present article describes the clinical and radiological features and the genetic implications of this syndrome. PMID:29042737
Nance-Horan Syndrome: A Rare Case Report.
Sharma, Shambhu; Datta, Pankaj; Sabharwal, Janak Raj; Datta, Sonia
2017-01-01
Dentofacial anomalies may guide us to the diagnosis of many congenital and hereditary syndromes. A 9-year-old boy was diagnosed with Nance-Horan syndrome. This syndrome is an extremely rare X-linked genetic disorder which is entirely expressed in males with semi-dominant transmission which results from mutations occurring in male gametes. It is characterized by facial dysmorphism such as long face, prominent nose and mandibular prognathism, ocular abnormalities such as congenital cataract, microcornea, microphthalmia and strabismus, and dental anomalies including mulberry molars and screwdriver-shaped incisors. Heterozygous females inherit this disease and also suffer from this syndrome but in a milder form. Approximately one-third of the affected males show signs of developmental delay and intellectual abnormalities. This syndrome is very rare and the incidence of the disease has not been established so far. The present article describes the clinical and radiological features and the genetic implications of this syndrome.
Automated Bone Screw Tightening to Adaptive Levels of Stripping Torque.
Reynolds, Karen J; Mohtar, Aaron A; Cleek, Tammy M; Ryan, Melissa K; Hearn, Trevor C
2017-06-01
To use relationships between tightening parameters, related to bone quality, to develop an automated system that determines and controls the level of screw tightening. An algorithm relating current at head contact (IHC) to current at construct failure (Imax) was developed. The algorithm was used to trigger cessation of screw insertion at a predefined tightening level, in real time, between head contact and maximum current. The ability of the device to stop at the predefined level was assessed. The mean (±SD) current at which screw insertion ceased was calculated to be [51.47 ± 9.75% × (Imax - IHC)] + IHC, with no premature bone failures. A smart screwdriver was developed that uses the current from the motor driving the screw to predict the current at which the screw will strip the bone threads. The device was implemented and was able to achieve motor shut-off and cease tightening at a predefined threshold, with no premature bone failures.
Design options for improving protective gloves for industrial assembly work.
Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W
2014-07-01
The study investigated the effects of wearing two new designs of cotton glove on several hand performance capabilities and compared them against the effects of barehanded, single-layered and double cotton glove conditions when working with hand tools (screwdriver and pliers). The new glove designs were based on the findings of subjective hand discomfort assessments for this type of work and aimed to match the glove thickness to the localised pressure and sensitivity in different areas of the hand as well as to provide adequate dexterity for fine manipulative tasks. The results showed that the first prototype glove and the barehanded condition were comparable and provided better dexterity and higher handgrip strength than double thickness gloves. The results support the hypothesis that selective thickness in different areas of the hand could be applied by glove manufacturers to improve the glove design, so that it can protect the hands from the environment and at the same time allow optimal hand performance capabilities. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Mapreduce is Good Enough? If All You Have is a Hammer, Throw Away Everything That's Not a Nail!
Lin, Jimmy
2013-03-01
Hadoop is currently the large-scale data analysis "hammer" of choice, but there exist classes of algorithms that aren't "nails" in the sense that they are not particularly amenable to the MapReduce programming model. To address this, researchers have proposed MapReduce extensions or alternative programming models in which these algorithms can be elegantly expressed. This article espouses a very different position: that MapReduce is "good enough," and that instead of trying to invent screwdrivers, we should simply get rid of everything that's not a nail. To be more specific, much discussion in the literature surrounds the fact that iterative algorithms are a poor fit for MapReduce. The simple solution is to find alternative, noniterative algorithms that solve the same problem. This article captures my personal experiences as an academic researcher as well as a software engineer in a "real-world" production analytics environment. From this combined perspective, I reflect on the current state and future of "big data" research.
Esthetic abutment design for angulated screw channels: A technical report.
Sakamoto, Satoshi; Ro, Munehiko; Al Ardah, Aladdin; Goodacre, Charles
2017-11-15
Angulated screw channel system abutments (ASCs) have recently been introduced to address the problem with visible screw access that may compromise esthetics. ASCs allow the screw access to be modified up to 25 degrees relative to the implant axis. However, a widened channel, which may cause thinning of the facial ceramic, is needed at the implant screw head to allow for proper engagement of the screwdriver. This technical report introduces a custom titanium insert design, the Satoshi Sakamoto (SS) abutment. The SS abutment consists of a custom titanium metal insert and zirconia coping in which the access hole is located in an esthetic position with an ASC system. The SS abutment results in a crown with more normal crown dimensions that also provides more space for the soft tissues. This SS abutment design allows clinicians to obtain screw-retained restorations with optimal esthetics and mechanical strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Deliberador, Tatiana Miranda; Marengo, Gláucia; Scaratti, Rodrigo; Giovanini, Allan Fernando; Zielak, João César; Baratto Filho, Flares
2011-01-01
This article reports on a case history of an elderly patient with Parkinson's disease (PD) who sought treatment at a private dental office. His chief complaint was "difficulty in eating due to an illfitting prosthesis." Laboratory tests and oral radiographs were made. The surgical placement of an implant was done and, subsequently, an implant-supported prosthesis was fitted for the patient. During the impression for the construction of the implant-supported prosthesis, the patient accidentally aspirated the implant screwdriver. The object was found in the lower right lobe of the bronchus, and its removal was necessary in a hospital using bronchoscopy under general anesthesia. Patients with PD are considered at risk of aspirating and/or ingesting dental instruments. Short treatment periods are recommended, preferably during the morning, when the medication prescribed for PD is most effective. When treating patients who have a risk for aspirating and ingesting small objects, it is important to treat them in a more vertical position, and small-sized objects should be secured with dental floss to aid retrieval. © 2011 Special Care Dentistry Association and Wiley Periodicals, Inc.
Recommended placement torque when tightening an orthodontic mini-implant.
Motoyoshi, Mitsuru; Hirabayashi, Masayuki; Uemura, Miwa; Shimizu, Noriyoshi
2006-02-01
To determine an adequate placement torque for obtaining a better success rate of mini-implants that are screwed into the buccal alveolar bone of the posterior region as an anchor for orthodontic treatment, implant placement torque (IPT) was measured. The subjects were 41 orthodontic patients (124 implants), with an average age of 24.9 years (SD 6.5 years), who had surgery to place titanium mini-implants. The peak value of IPT was measured using a torque screwdriver. The success rate of the mini-implant anchor for 124 implants was 85.5%. The mean IPT ranged from 7.2 to 13.5 N cm, depending on the location of the implants. There was a significant difference in the IPT between maxilla and mandible. The IPT in the mandible was, unexpectedly, significantly higher in the failure group than in the success group. Therefore, a large IPT should not be used always. According to our calculations of the risk ratio for failure, to raise the success rate of 1.6-mm diameter mini-implants, the recommended IPT is within the range from 5 to 10 N cm.
Tan, Keson B; Nicholls, Jack I
2002-01-01
This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. Electronic torque controllers should be regularly recalibrated to ensure optimal output.
Abstract Representations of Object-Directed Action in the Left Inferior Parietal Lobule.
Chen, Quanjing; Garcea, Frank E; Jacobs, Robert A; Mahon, Bradford Z
2018-06-01
Prior neuroimaging and neuropsychological research indicates that the left inferior parietal lobule in the human brain is a critical substrate for representing object manipulation knowledge. In the present functional MRI study we used multivoxel pattern analyses to test whether action similarity among objects can be decoded in the inferior parietal lobule independent of the task applied to objects (identification or pantomime) and stimulus format in which stimuli are presented (pictures or printed words). Participants pantomimed the use of objects, cued by printed words, or identified pictures of objects. Classifiers were trained and tested across task (e.g., training data: pantomime; testing data: identification), stimulus format (e.g., training data: word format; testing format: picture) and specific objects (e.g., training data: scissors vs. corkscrew; testing data: pliers vs. screwdriver). The only brain region in which action relations among objects could be decoded across task, stimulus format and objects was the inferior parietal lobule. By contrast, medial aspects of the ventral surface of the left temporal lobe represented object function, albeit not at the same level of abstractness as actions in the inferior parietal lobule. These results suggest compulsory access to abstract action information in the inferior parietal lobe even when simply identifying objects.
Effect of laundering on visible damage to apparel fabric caused by sharp force impact.
Wells, S L; Laing, R M; Carr, D J; Niven, B E
2013-12-10
Sharp force violence is a common way of committing assault in numerous countries and regions around the world. When a stabbing occurs, the clothing worn by the victim may provide vital evidence: for example the weapon used to stab the victim may be identified from severance in the clothing. However, whether laundering the clothing after an attack affects the severance morphology of the fabric and fibres, and whether identification of the weapon is possible from the severance in the clothing after laundering is not known. This study focussed on the effect of laundering 100% cotton twill weave (drill) and single jersey (knit) fabrics. Specimens had been pre-treated and stabbed with either a kitchen knife or a Phillips screwdriver. These specimens were photographed and were again laundered for one wash cycle before being photographed again. Ten expert judges compared the photographs taken before and after laundering. A difference in the appearance of the fabrics before and after laundering was evident. The morphology of the fabric and fibres thus would be expected to differ after laundering the clothing, making identification of a weapon used to stab through clothing more difficult. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Chumbley, Scott; Zhang, Song; Morris, Max; ...
2016-11-16
Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less
Nance-Horan syndrome-The oral perspective on a rare disease.
Gjørup, Hans; Haubek, Dorte; Jacobsen, Pernille; Ostergaard, John R
2017-01-01
The present study describes seven patients with Nance-Horan syndrome, all referred to a specialized oral care unit in the Central Denmark Region. A literature search on "Nance Horan Syndrome" resulted in 53 publications among which 29 reported on dental findings. Findings reported in these papers have been systematized to obtain an overview of the reported findings and the terminology on dental morphology. All seven patients included in the present study showed deviations of crown morphology on incisors and/or molars. The only consistent and very clear dental aberration was alterations in the tooth morphology that is screwdriver-shaped incisors and bud molars being most pronounced in the permanent dentition, but were also present in the primary dentition. In addition, three patients had supernumerary teeth, and three had dental agenesis. In conclusion, a dental examination as a part of the diagnostic process may reveal distinct characteristics of the dental morphology, which could be of diagnostic value and facilitate an early diagnosis. In the description of molar morphology in NHS patients, it is recommended to use the term "bud molar." The combination of congenital cataract, screwdriwer-shaped incisors and bud-shaped molars is a strong clinical indication of Nance-Horan syndrome. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Rieder, Jocelyn; Brusky, John; Tran, Viet; Stern, Karen; Aboseif, Sherif
2010-01-01
Retrospective evaluation of a series of patients presenting with genitourinary foreign objects. From 1997 to 2007, 11 men and 2 women were treated for a variety of foreign objects in the genitourinary tract. Medical records were reviewed for presentation, diagnosis, mental status, drug dependency, treatment, and follow-up. 13 patients were seen for removal of the foreign objects or for treatment of the sequela. These objects were intentionally self-inflicted, accidentally introduced or iatrogenic in nature. Intentional objects included: safety pins, screwdriver, marbles, pen cap, pencils, straw, cocaine, stiff metal wire and part of a pizza mixer. Accidental objects included: magnets, female catheter, urinary incontinence devices and part of a Foley catheter. The iatrogenic object was a reservoir from an inflatable penile implant. Smaller noninjurious objects were retrieved cystoscopically or at the bedside; larger objects or objects associated with trauma to the urethra needed open and reconstructive operations. Generally thought to be self-inflicted for personal gratification, the source of genitourinary objects can also be accidental or iatrogenic. The most traumatic injuries are purposely self-inflicted and found in patients who remove the objects themselves. These patients are at higher risk of permanent urethral damage needing complex surgical treatment and follow-up. Copyright (c) 2010 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chumbley, Scott; Zhang, Song; Morris, Max
Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less
NASA Astrophysics Data System (ADS)
Delvecchio, S.; Antoni, J.
2012-02-01
This paper addresses the use of a cyclostationary blind source separation algorithm (namely RRCR) to extract angle deterministic signals from mechanical rotating machines in presence of stationary speed fluctuations. This means that only phase fluctuations while machine is running in steady-state conditions are considered while run-up or run-down speed variations are not taken into account. The machine is also supposed to run in idle conditions so non-stationary phenomena due to the load are not considered. It is theoretically assessed that in such operating conditions the deterministic (periodic) signal in the angle domain becomes cyclostationary at first and second orders in the time domain. This fact justifies the use of the RRCR algorithm, which is able to directly extract the angle deterministic signal from the time domain without performing any kind of interpolation. This is particularly valuable when angular resampling fails because of uncontrolled speed fluctuations. The capability of the proposed approach is verified by means of simulated and actual vibration signals captured on a pneumatic screwdriver handle. In this particular case not only the extraction of the angle deterministic part can be performed but also the separation of the main sources of excitation (i.e. motor shaft imbalance, epyciloidal gear meshing and air pressure forces) affecting the user hand during operations.
Experimenting `learn by doing' and `learn by failing'
NASA Astrophysics Data System (ADS)
Pozzi, Rossella; Noè, Carlo; Rossi, Tommaso
2015-01-01
According to the literature, in recent years, developing experiential learning has fulfilled the requirement of a deep understanding of lean philosophy by engineering students, demonstrating the advantages and disadvantages of some of the key principles of lean manufacturing. On the other hand, the literature evidences how some kinds of game-based experiential learning overlook daily difficulties, which play a central role in manufacturing systems. To fill the need of a game overcoming such lack of vision, an innovative game direct in-field, named Kart Factory, has been developed. Actual production shifts are simulated, while keeping all the elements peculiar to a real production set (i.e. complexity, effort, safety). The working environment is a real pedal car assembly department, the products to be assembled have relevant size and weight (i.e. up to 35 kg approximately), and the provided tools are real production equipment (e.g. keys, screwdrivers, trans-pallets, etc.). Due to the need to maximise the impact on students, a labour-intensive process characterises the production department. The whole training process is based on three educational principles: Experience Value Principle, Error Value Principle, and Team Value Principle. As the 'learn by doing' and 'learn by failing' are favoured, the theory follows the practice, while crating the willingness to 'do' instead of just designing or planning. The gathered data prove the Kart Factory's effectiveness in reaching a good knowledge of lean concepts, notwithstanding the students' initial knowledge level.
Aeroperformance and Acoustics of the Nozzle with Permeable Shell
NASA Technical Reports Server (NTRS)
Gilinsky, M.; Blankson, I. M.; Chernyshev, S. A.; Chernyshev, S. A.
1999-01-01
Several simple experimental acoustic tests of a spraying system were conducted at the NASA Langley Research Center. These tests have shown appreciable jet noise reduction when an additional cylindrical permeable shell was employed at the nozzle exit. Based on these results, additional acoustic tests were conducted in the anechoic chamber AK-2 at the Central Aerohydrodynamics Institute (TsAGI, Moscow) in Russia. These tests examined the influence of permeable shells on the noise from a supersonic jet exhausting from a round nozzle designed for exit Mach number, M (sub e)=2.0, with conical and Screwdriver-shaped centerbodies. The results show significant acoustic benefits of permeable shell application especially for overexpanded jets by comparison with impermeable shell application. The noise reduction in the overall pressure level was obtained up to approximately 5-8%. Numerical simulations of a jet flow exhausting from a convergent-divergent nozzle designed for exit Mach number, M (sub e)=2.0, with permeable and impermeable shells were conducted at the NASA LaRC and Hampton University. Two numerical codes were used. The first is the NASA LaRC CFL3D code for accurate calculation of jet mean flow parameters on the basis of a full Navier-Stokes solver (NSE). The second is the numerical code based on Tam's method for turbulent mixing noise (TMN) calculation. Numerical and experimental results are in good qualitative agreement.
Objective analysis of toolmarks in forensics
NASA Astrophysics Data System (ADS)
Grieve, Taylor N.
Since the 1993 court case of Daubert v. Merrell Dow Pharmaceuticals, Inc. the subjective nature of toolmark comparison has been questioned by attorneys and law enforcement agencies alike. This has led to an increased drive to establish objective comparison techniques with known error rates, much like those that DNA analysis is able to provide. This push has created research in which the 3-D surface profile of two different marks are characterized and the marks' cross-sections are run through a comparative statistical algorithm to acquire a value that is intended to indicate the likelihood of a match between the marks. The aforementioned algorithm has been developed and extensively tested through comparison of evenly striated marks made by screwdrivers. However, this algorithm has yet to be applied to quasi-striated marks such as those made by the shear edge of slip-joint pliers. The results of this algorithm's application to the surface of copper wire will be presented. Objective mark comparison also extends to comparison of toolmarks made by firearms. In an effort to create objective comparisons, microstamping of firing pins and breech faces has been introduced. This process involves placing unique alphanumeric identifiers surrounded by a radial code on the surface of firing pins, which transfer to the cartridge's primer upon firing. Three different guns equipped with microstamped firing pins were used to fire 3000 cartridges. These cartridges are evaluated based on the clarity of their alphanumeric transfers and the clarity of the radial code surrounding the alphanumerics.
Titanium alloy vs. stainless steel miniscrews: an in vivo split-mouth study.
Bollero, P; Di Fazio, V; Pavoni, C; Cordaro, M; Cozza, P; Lione, R
2018-04-01
To compare in vivo Titanium Alloy (TiA) with Stainless Steel (SS) miniscrews Temporary Anchorage Devices (TADs) using removal torque and Scanning Electron Microscopic (SEM) analysis. 15 subjects (6 males and 9 females) who required maximum anchorage were recruited. For each patient, a TiA TAD and a SS TAD with same length and width were implanted following a randomized split-mouth study design. Retraction was carried out with nickel-titanium spring ligated directly from the anterior hooks of the archwire to the TADs to produce 90 to 100 g of force. When no further anchorage supplementation was needed, the TADs were removed. The removal torque values were registered with a digital screwdriver. After removal, the TADs were collected in a fixed solution and examined using SEM and X-ray microanalysis. All TADs remained intact, with a 100% success rate. There was no difference in removal torque between TiA and SS miniscrews (4.4 ± 1.3 N-cm and 5.1 ± 0.7 N-cm, respectively). All specimens' loss of gloss with signs of biological contaminations resulted in a dull implant surface. SEM photomicrographs of TiA miniscrews showed predominantly blood cells while SS miniscrews showed the precipitation of an amorphous layer with low cellular component. There was no difference in spectroscopic analysis between TiA and SS miniscrews. TiA and SS miniscrews had comparable removal torque values. SEM photomicrographs showed no evidence of osseointegration with both TADs having similar biological responses.
Objective analysis of toolmarks in forensics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grieve, Taylor N.
2013-01-01
Since the 1993 court case of Daubert v. Merrell Dow Pharmaceuticals, Inc. the subjective nature of toolmark comparison has been questioned by attorneys and law enforcement agencies alike. This has led to an increased drive to establish objective comparison techniques with known error rates, much like those that DNA analysis is able to provide. This push has created research in which the 3-D surface profile of two different marks are characterized and the marks’ cross-sections are run through a comparative statistical algorithm to acquire a value that is intended to indicate the likelihood of a match between the marks. Themore » aforementioned algorithm has been developed and extensively tested through comparison of evenly striated marks made by screwdrivers. However, this algorithm has yet to be applied to quasi-striated marks such as those made by the shear edge of slip-joint pliers. The results of this algorithm’s application to the surface of copper wire will be presented. Objective mark comparison also extends to comparison of toolmarks made by firearms. In an effort to create objective comparisons, microstamping of firing pins and breech faces has been introduced. This process involves placing unique alphanumeric identifiers surrounded by a radial code on the surface of firing pins, which transfer to the cartridge’s primer upon firing. Three different guns equipped with microstamped firing pins were used to fire 3000 cartridges. These cartridges are evaluated based on the clarity of their alphanumeric transfers and the clarity of the radial code surrounding the alphanumerics.« less
Activity recognition of assembly tasks using body-worn microphones and accelerometers.
Ward, Jamie A; Lukowicz, Paul; Tröster, Gerhard; Starner, Thad E
2006-10-01
In order to provide relevant information to mobile users, such as workers engaging in the manual tasks of maintenance and assembly, a wearable computer requires information about the user's specific activities. This work focuses on the recognition of activities that are characterized by a hand motion and an accompanying sound. Suitable activities can be found in assembly and maintenance work. Here, we provide an initial exploration into the problem domain of continuous activity recognition using on-body sensing. We use a mock "wood workshop" assembly task to ground our investigation. We describe a method for the continuous recognition of activities (sawing, hammering, filing, drilling, grinding, sanding, opening a drawer, tightening a vise, and turning a screwdriver) using microphones and three-axis accelerometers mounted at two positions on the user's arms. Potentially "interesting" activities are segmented from continuous streams of data using an analysis of the sound intensity detected at the two different locations. Activity classification is then performed on these detected segments using linear discriminant analysis (LDA) on the sound channel and hidden Markov models (HMMs) on the acceleration data. Four different methods at classifier fusion are compared for improving these classifications. Using user-dependent training, we obtain continuous average recall and precision rates (for positive activities) of 78 percent and 74 percent, respectively. Using user-independent training (leave-one-out across five users), we obtain recall rates of 66 percent and precision rates of 63 percent. In isolation, these activities were recognized with accuracies of 98 percent, 87 percent, and 95 percent for the user-dependent, user-independent, and user-adapted cases, respectively.
Toler, Julianne D; Petschauer, Meredith A; Mihalik, Jason P; Oyama, Sakiko; Halverson, S Doug; Guskiewicz, Kevin M
2010-03-01
To determine how head movement and time to access airway were affected by 3 emergency airway access techniques used in American football. Prospective counterbalanced design. University research laboratory. Eighteen certified athletic trainers (ATCs) and 18 noncertified students (NCSs). Each participant performed 1 trial of each of the 3 after airway access techniques: quick release mechanism (QRM), cordless screwdriver (CSD), and pocket mask insertion (PMI). Time to task completion in seconds, head movement in each plane (sagittal, frontal, and transverse), maximum head movement in each plane, helmet movement in each plane, and maximum helmet movement in each plane. We observed a significant difference between all 3 techniques with respect to time required to achieve airway access (F(2,68) = 263.88; P < 0.001). The PMI allowed for the quickest access followed by the QRM and CSD techniques, respectively. The PMI technique also resulted in significantly less head movement (F(2,68) = 9.06; P = 0.001) and less maximum head movement (F(2,68) = 13.84; P < 0.001) in the frontal plane compared with the QRM and CSD techniques. The PMI technique should be used to gain rapid airway access when managing a football athlete experiencing respiratory arrest in the presence of a suspected cervical spine injury. In the event the athlete does not present with respiratory arrest, the facemask may be removed carefully with a pocket mask ready. Medical professionals must be familiar with differences in equipment and the effects these may have on the management of the spine-injured athlete.
NASA Technical Reports Server (NTRS)
Chandler, Faith; Garton, Harry; Valentino, Bill; Amett, Mike
2005-01-01
The Fastener Starter is a creative solution to prevent the loss of small fasteners during their installation. This is the only currently available tool that can firmly grip and hold a single screw, bolt, nut, washer, spacer, or any combination of these parts. Other commercially available fastener starters are unable to accommodate a variety of parts simultaneously. The Fastener Starter is a more capable and easier tool to use than prior tools. Its compact size allows it to be used effectively in cramped, difficult-to-see locations. Its design also allows it to be used with or without handles and extenders in other difficult-to-reach locations. It provides better protection against cross threading and loss of fasteners and associated parts. The Fastener Starter is non-magnetic and does not off-gas, thus meeting flight hardware requirements. The Fastener Starter incorporates a combination of features of several commercially available tools, providing an improved means of installing small fasteners. The Fastener Starter includes a custom molded insert that can be removed easily and replaced with a conventional tool bit (e.g., a screwdriver or hex-driver bit). When used with the insert, the Fastener Starter prevents cross threading and damage to internal threaded holes. This is achieved by allowing the fastener to slip within the tool insert when used without a conventional tool bit. Alternatively, without the insert and with a tool bit, the Fastener Starter can torque a fastener. The Fastener Starter has a square recess hole that accepts a conventional square drive handle or extension to accommodate a variety of applications by providing flexibility in handle style and length.
Retained weapon injuries: experience from a civilian metropolitan trauma service in South Africa.
Kong, V; Khan, Z; Cacala, S; Oosthuizen, G; Clarke, D
2015-04-01
Retained weapon (RW) injuries are uncommon, but there is no current consensus on the best management approach. We reviewed our experience of 102 consecutive patients with non-missile RWs in a high-volume metropolitan trauma service managed over a 10-year period. Of the 102 patients, 95 were males (93%), 7 were females (7%), and median age was 24 (21-28) years. Weapons: 73% (74/102) knives, 17% (17/102) screwdrivers, 5% spears, 6% (6/102) others [axe (1), glass fragment (1), stick (1), sickle blade (1), wire (1) and stone (1)]. 8% (8/102) head, 20% (20/102) in the face, 9% (9/102) neck, 14% (14/102) thorax, 25% (26/102) abdomen, 23% (23/102) upper limb, 2% (2/102) lower limb. Four per cent (4/102) were haemodynamically unstable and proceed immediately to the operating theatre for operative exploration and weapon extraction. Imagining: 88 (86%) plain radiographs, 65 (64%) non-contrast CT scans, 41 (40%) contrast CT angiography, 4 (4%) formal angiography. Seventy-two underwent simple extraction, and 29 underwent extract plus open operation. One patient absconded. Specialist surgeons involved in extraction: trauma surgeons (74), neurosurgeons (10), ophthalmic surgeons (11) and ENT surgeons (4). Overall, 92% (94/102) survived to discharge. The vast majority of patients with RWs will be admitted in a stable condition and haemodynamic instability was almost exclusively seen in the anterior thorax. The most common site was the posterior abdomen. Detailed imagining should be used liberally in stable patients and unplanned extraction in an uncontrolled environment should be strongly discouraged.
A possible cranio-oro-facial phenotype in Cockayne syndrome
2013-01-01
Background Cockayne Syndrome CS (Type A – CSA; or CS Type I OMIM #216400) (Type B – CSB; or CS Type II OMIM #133540) is a rare autosomal recessive neurological disease caused by defects in DNA repair characterized by progressive cachectic dwarfism, progressive intellectual disability with cerebral leukodystrophy, microcephaly, progressive pigmentary retinopathy, sensorineural deafness photosensitivity and possibly orofacial and dental anomalies. Methods We studied the cranio-oro-facial status of a group of 17 CS patients from 15 families participating in the National Hospital Program for Clinical Research (PHRC) 2005 « Clinical and molecular study of Cockayne syndrome ». All patients were examined by two investigators using the Diagnosing Dental Defects Database (D[4]/phenodent) record form. Results Various oro-facial and dental anomalies were found: retrognathia; micrognathia; high- arched narrow palate; tooth crowding; hypodontia (missing permanent lateral incisor, second premolars or molars), screwdriver shaped incisors, microdontia, radiculomegaly, and enamel hypoplasia. Eruption was usually normal. Dental caries was associated with enamel defects, a high sugar/carbohydrate soft food diet, poor oral hygiene and dry mouth. Cephalometric analysis revealed mid-face hypoplasia, a small retroposed mandible and hypo-development of the skull. Conclusion CS patients may have associated oro-dental features, some of which may be more frequent in CS children – some of them being described for the first time in this paper (agenesis of second permanent molars and radiculomegaly). The high susceptibility to rampant caries is related to a combination of factors as well as enamel developmental defects. Specific attention to these anomalies may contribute to diagnosis and help plan management. PMID:23311583
Kong, V Y; Oosthuizen, G V; Clarke, D L
2015-02-01
The selective conservative management of small pneumothoraces (PTXs) following stab injuries is controversial. We reviewed a cohort of patients managed conservatively in a high volume trauma service in South Africa. A retrospective review over a 2-year period identified 125 asymptomatic patients with small PTXs measuring <2 cm on chest radiograph who were managed conservatively. Of the 125 patients included in the study, 92% were male (115/125), and the median age for all patients was 21 years (19-24). Ninety-seven per cent (121/125) of the weapons involved were knives, and 3% (4/125) were screwdrivers. Sixty-one per cent of all injuries were on the left side. Eighty-two per cent (102/125) sustained a single stab, and 18% (23/125) had multiple stabs. Thirty-nine per cent (49/125) had a PTX <0.5 cm (Group A), 26% (32/125) were ≥ 0.5 to <1 cm (Group B), 19% (24/125) were ≥ 1 to <1.5 cm (Group C) and 15% (20/125) were ≥ 1.5 to <2 cm (Group D). Three per cent of all patients (4/125) eventually required ICDs (one in Group C, three in Group D). All four patients had ICDs in situ for 24 h. The remaining 97% (121/125) were all managed successfully by active clinical observation alone. There were no subsequent readmissions, morbidity or mortality as a direct result of our conservative approach. The selective conservative management of asymptomatic small PTXs from stab injuries is safe if undertaken in the appropriate setting.
Experimental investigation of the fracture torque of orthodontic anchorage screws.
Reimann, Susanne; Ayubi, Mustafa; McDonald, Fraser; Bourauel, Christoph
2016-07-01
In contrast to dental implants that remain in the bone, orthodontic anchorage screws serve as temporary anchorage for orthodontic tooth movement and are removed after completion of treatment. The aim of the present study was to evaluate the stability of various commercially available orthodontic anchorage screws against torsion. The torsional deflection of ten different orthodontic anchorage screws from different manufacturers [Ortho Easy Pin (Forestadent), Benefit, quattro (both PSM Medical Solutions), Vector TAS (Ormco), AbsoAnchor(®) (DENTOS Inc.), OrthoLox, Dual-Top JA (both Promedia Medizintechnik), TAD (3M Unitek), INFINITAS (ODS) and tomas(®) (Dentaurum)] was tested in vitro in relation to the rotation angle using a self-developed set-up. The screws were positioned in a resin model with bone-like material properties. Shear tests were performed using the manufacturers' own screwdrivers. Ten screws each were turned manually until a sudden drop in the measured torque occurred. At this point, the screw head was twisted off. Fracture torque and the torque at which the screws deformed plastically were evaluated. Mean values and standard deviations were calculated. According to the German industrial standard, the torque of orthodontic anchorage screws should reach at least 20 Ncm. The majority of the screws reached this nominal torque; however, a few screws fractured before reaching this value. Five screw types displayed plastic deformation below the threshold, at approximately 16 Ncm. The results suggest that orthodontic anchorage screws generally meet the requirements of the standard and ensure safe clinical use. However, according to the present data, it may be assumed that a portion of the screws will be plastically deformed upon removal.
Singh, Harpreet; Sharma, Rohit; Gupta, Sachin; Singh, Narinderjit; Singh, Simarpreet
2015-01-01
The advent of locking plates has brought new problems in implant removal. Difficulty in removing screws from a locking plate is well-known. These difficulties include cold welding between the screw head and locking screw hole, stripping of the recess of the screw head for the screwdriver, and cross-threading between threads in the screw head and screw hole. However, there are cases in which removal is difficult. We describe a new technique for removing a round headed, jammed locking screws from a locking plate. 55 years old male patient received a locking distal tibial plate along with distal fibular plate 3years back from UAE. Now patient came with complaint of non-healing ulcer over medial aspect of lower 1/3rd of right leg from past 1 year. Non operative management did not improve the symptoms. The patient consented to implant removal, with the express understanding that implant removal might be impossible because already one failed attempt had been performed at some other hospital six months back. We then decided to proceed with the new technique. The rest of the proximal screws were removed using a technique not previously described. We used stainless steel metal cutting blades that are used to cut door locks or pad locks to cut the remaining stripped headed screws. This technique is very quick, easy to perform and inexpensive because the metal cutting blades which are used to cut the screws are very cheap. Yet it is very effective technique to remove the stripped headed or jammed locking screws. It is also very less destructive because of very less heat production during the procedure there is no problem of thermal necrosis to the bone or the surrounding soft tissue.
Kong, V Y; Sartorius, B; Clarke, D L
2015-12-01
Accurate physical examination (PE) remains a key component in the assessment of penetrating thoracic trauma (PTT), despite the increasing availability of advanced radiological imaging. Evidence regarding the accuracy of PE in identifying significant pathology following PTT is limited. A retrospective review of 405 patients was undertaken over a twelve-month period to determine the accuracy of PE in identifying significant pathology (SP) subsequently confirmed on chest radiographs (CXRs) in patients who sustained stab injuries to the thorax. Ninety-seven per cent (372/405) of patients were males, and the mean age was 24 years. The weapons involved were knives in 98 % (398/405), screwdrivers in 1 % (3/405) and unknown in the remaining 1 %. Fifty-nine per cent (238/405) of all injuries were on the left side. There were 306 (76 %) SPs identified on CXR. Ninety-nine (24 %) CXRs were entirely normal. Based on PE alone, 223 (55 %) patients were thought to have SPs present, 182 (45 %) patients were thought to have no SPs. The overall sensitivity of PE in identifying SPs was 68 % (63-73, 95 % CI), with a specificity of 86 % (77-92, 95 % CI). The PPV of PE was 94 % (90-97, 95 % CI) and the NPV was 47 % (39-54, 95 % CI). The sensitivity of PE for identifying a pneumothorax was 59 % (51-66, 95 % CI), with a specificity of 96 % (89-99, 95 % CI) and the sensitivity of PE for identifying a haemothorax was 79 % (72-86, 95 % CI), with a specificity of 96 % (89-99, 95 % CI). PE is inaccurate in identifying SPs in PTT. The increased reliance on advanced radiological imaging and the subsequent reduced emphasis on PE may have contributed to rapid deskilling amongst surgical residents. The importance of PE must be repeatedly re-emphasised.
Disentangling representations of shape and action components in the tool network.
Wang, Xiaoying; Zhuang, Tonghe; Shen, Jiasi; Bi, Yanchao
2018-05-30
Shape and how they should be used are two key components of our knowledge about tools. Viewing tools preferentially activated a frontoparietal and occipitotemporal network, with dorsal regions implicated in computation of tool-related actions and ventral areas in shape representation. As shape and manners of manipulation are highly correlated for daily tools, whether they are independently represented in different regions remains inconclusive. In the current study, we collected fMRI data when participants viewed blocks of pictures of four daily tools (i.e., paintbrush, corkscrew, screwdriver, razor) where shape and action (manner of manipulation for functional use) were orthogonally manipulated, to tease apart these two dimensions. Behavioral similarity judgments tapping on object shape and finer aspects of actions (i.e., manners of motion, magnitude of arm movement, configuration of hand) were also collected to further disentangle the representation of object shape and different action components. Information analysis and representational similarity analysis were conducted on regional neural activation patterns of the tool-preferring network. In both analyses, the bilateral lateral occipitotemporal cortex showed robust shape representations but could not effectively distinguish between tool-use actions. The frontal and precentral regions represented kinematic action components, whereas the left parietal region (in information analyses) exhibited coding of both shape and tool-use action. By teasing apart shape and action components, we found both dissociation and association of them within the tool network. Taken together, our study disentangles representations for object shape from finer tool-use action components in the tool network, revealing the potential dissociable roles different tool-preferring regions play in tool processing. Copyright © 2018 Elsevier Ltd. All rights reserved.
Tape underlayment rotary-node (TURN) valves for simple on-chip microfluidic flow control
Markov, Dmitry A.; Manuel, Steven; Shor, Leslie M.; Opalenik, Susan R.; Wikswo, John P.; Samson, Philip C.
2013-01-01
We describe a simple and reliable fabrication method for producing multiple, manually activated microfluidic control valves in polydimethylsiloxane (PDMS) devices. These screwdriver-actuated valves reside directly on the microfluidic chip and can provide both simple on/off operation as well as graded control of fluid flow. The fabrication procedure can be easily implemented in any soft lithography lab and requires only two specialized tools – a hot-glue gun and a machined brass mold. To facilitate use in multi-valve fluidic systems, the mold is designed to produce a linear tape that contains a series of plastic rotary nodes with small stainless steel machine screws that form individual valves which can be easily separated for applications when only single valves are required. The tape and its valves are placed on the surface of a partially cured thin PDMS microchannel device while the PDMS is still on the soft-lithographic master, with the master providing alignment marks for the tape. The tape is permanently affixed to the microchannel device by pouring an over-layer of PDMS, to form a full-thickness device with the tape as an enclosed underlayment. The advantages of these Tape Underlayment Rotary-Node (TURN) valves include parallel fabrication of multiple valves, low risk of damaging a microfluidic device during valve installation, high torque, elimination of stripped threads, the capabilities of TURN hydraulic actuators, and facile customization of TURN molds. We have utilized these valves to control microfluidic flow, to control the onset of molecular diffusion, and to manipulate channel connectivity. Practical applications of TURN valves include control of loading and chemokine release in chemotaxis assay devices, flow in microfluidic bioreactors, and channel connectivity in microfluidic devices intended to study competition and predator / prey relationships among microbes. PMID:19859812
Surface characteristics of clinically used dental implant screws
NASA Astrophysics Data System (ADS)
Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon
2005-12-01
Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.
Engineering of Impulse Mechanism for Mechanical Hander Power Tools
NASA Astrophysics Data System (ADS)
Nikolaevich Drozdov, Anatoliy
2018-03-01
The solution to the problem of human security in cities should be considered on the basis of an integrated and multidisciplinary approach, including issues of security and ecology in the application of technical means used to ensure the viability and development of technocracy. In this regard, an important task is the creation of a safe technique with improved environmental properties with high technological characteristics. This primarily relates to mechanised tool — the division of technological machines with built in engines is that their weight is fully or partially perceived by the operator’s hands, making the flow and control of the car. For this subclass of machines is characterized by certain features: a built-in motor, perception of at least part of their weight by the operator during the work, the implementation of feeding and management at the expense of the muscular power of the operator. Therefore, among the commonly accepted technical and economic characteristics, machines in this case, important ergonomic (ergonomics), regulation of levels which ensures the safety of the operator. To ergonomics include vibration, noise characteristics, mass, and force feeding machine operator. Vibration is a consequence of the dynamism of the system operator machine - processed object (environment) in which the engine energy is redistributed among all the structures, causing their instability. In the machine vibration caused by technological and constructive (transformative mechanisms) unbalance of individual parts of the drive, the presence of technological and design (impact mechanisms) clearances and other reasons. This article describes a new design of impulse mechanism for hander power tools (wrenches, screwdrivers) with enhanced torque. The article substantiates a simulation model of dynamic compression process in an operating chamber during impact, provides simulation results and outlines further lines of research.
Kalénine, Solène; Buxbaum, Laurel J.
2016-01-01
Converging evidence supports the existence of functionally and neuroanatomically distinct taxonomic (similarity-based; e.g., hammer-screwdriver) and thematic (event-based; e.g., hammer-nail) semantic systems. Processing of thematic relations between objects has been shown to selectively recruit the left posterior temporoparietal cortex. Similar posterior regions have been also been shown to be critical for knowledge of relationships between actions and manipulable human-made objects (artifacts). Based on the hypothesis that thematic relationships for artifacts are based, at least in part, on action relationships, we assessed the prediction that the same regions of the left posterior temporoparietal cortex would be critical for conceptual processing of artifact-related actions and thematic relations for artifacts. To test this hypothesis, we evaluated processing of taxonomic and thematic relations for artifact and natural objects as well as artifact action knowledge (gesture recognition) abilities in a large sample of 48 stroke patients with a range of lesion foci in the left hemisphere. Like control participants, patients identified thematic relations faster than taxonomic relations for artifacts, whereas they identified taxonomic relations faster than thematic relations for natural objects. Moreover, response times for identifying thematic relations for artifacts selectively predicted performance in gesture recognition. Whole brain Voxel Based Lesion-Symptom Mapping (VLSM) analyses and Region of Interest (ROI) regression analyses further demonstrated that lesions to the left posterior temporal cortex, overlapping with LTO and visual motion area hMT+, were associated both with relatively slower response times in identifying thematic relations for artifacts and poorer artifact action knowledge in patients. These findings provide novel insights into the functional role of left posterior temporal cortex in thematic knowledge, and suggest that the close association between thematic relations for artifacts and action representations may reflect their common dependence on visual motion and manipulation information. PMID:27389801
Bourgkard, Eve; Wild, Pascal; Massin, Nicole; Meyer, Jean-Pierre; Otero Sierra, Carmen; Fontana, Jean-Marc; Benamghar, Lahoucine; Mur, Jean-Marie; Ravaud, Jean-François; Guillemin, Francis; Chau, Nearkasen
2008-01-01
This study assessed the relationships of physical job demands (PJD), smoking, and alcohol abuse, with premature mortality before age 70 (PM-70) among the working or inactive population. The sample included 4,268 subjects aged 15 or more randomly selected in north-eastern France. They completed a mailed questionnaire (birth date, sex, weight, height, job, PJD, smoking habit, alcohol abuse (Deta questionnaire)) in 1996 and were followed for mortality until 2004 (9 yr). PJD score was defined by the cumulative number of the following high job demands at work: hammer, vibrating platform, pneumatic tools, other vibrating hand tools, screwdriver, handling objects, awkward posture, tasks at heights, machine tools, pace, working on a production line, standing about and walking. The data were analyzed using the Poisson regression model. Those with PM-70 were 126 (3.81 per 1,000 person-years). The leading causes of death were cancers (46.4% in men, 57.1% in women), cardiovascular diseases (20.2% and 11.9%), suicide (9.5% and 7.1%), respiratory diseases (6.0% and 4.8%), and digestive diseases (2.4% and 4.8%). PJD3, smoker, and alcohol abuse had adjusted risk ratios of 1.71 (95% CI 1.02-2.88), 1.76 (1.08-2.88), and 2.07 (1.31-3.26) respectively for all-cause mortality. Manual workers had a risk ratio of 1.84 (1.00-3.37) compared to the higher socio-economic classes. The men had a two-fold higher mortality rate than the women; this difference became non-significant when controlling for job, PJD, smoker and alcohol abuse. For cancer mortality the factors PJD3, smoker, and alcohol abuse had adjusted risk ratios of 2.00 (1.00-3.99), 2.34 (1.19-4.63), and 2.22 (1.17-4.20), respectively. Health promotion efforts should be directed at structural measures of task redesign and they should also concern lifestyle.
Whang, C Z Y; Bister, D; Sherriff, M
2011-12-01
This study compared peak insertion torque values of six commercially available self-drilling mini-implants [Mini Spider® screw (1.5 × 8 mm), Infinitas® (1.5 × 9 mm), Vector TAS® (1.4 × 8 mm), Dual Top® (1.6 × 8 mm), Tomas Pin® (1.6 × 8 mm), and Ortho-Easy® (1.7 × 6, 8, and 10 mm)]. Twenty implants each were drilled into acrylic rods at a speed of 8 rpm using a motorized torque measurement stand, and the values were recorded in Newton centimetres (Ncm). A further 20 Ortho-Easy® implants with a length of 6 and 10 mm were tested at 8 rpm; 20 implants of 6 mm length were also tested at 4 rpm. Kaplan-Meier estimates of the peak torque values were compared using the log-rank test with multiple comparisons evaluated by Sidak's test. There were significant differences in the maximum torque values for different mini-implants with the same length. The Mini Spider® screw and Infinitas® showed the lowest average torque values (6.5 and 12.4 Ncm) compared with Vector TAS®, Dual ToP®, Tomas Pin®, and Ortho-Easy® (30.9, 29.4, 25.4, and 24.8 Ncm, respectively). There was no correlation between the diameter of the implants and torque values. The Tomas Pin® showed the largest standard deviation (7.7 Ncm) and the Dual Top® implant the smallest (0.6 Ncm). Different insertion speeds did not result in significant differences in peak torque values but the 6 mm mini-implants showed significantly higher torque values than the 8 and 10 mm implants. Using a 'torque limiting' screwdriver or pre-drilling cortical bone to reduce insertion, torque appears justified for some of the tested implants.
Improving socket design to prevent difficult removal of locking screws.
Lin, Chen-Huei; Chao, Ching-Kong; Tang, Yi-Hsuan; Lin, Jinn
2018-03-01
Reports of driver slippage leading to difficult locking screw removals have increased since the adoption of titanium for screw fabrication; the use of titanium is known to cause cross-threading and cold welding. Such problems occur most frequently in screws with hex sockets, and may cause serious surgical complications. This study aimed to improve screw socket design to prevent slippage and difficult screw removal. Three types of small sockets (hex, Torx, and cruciate) and six types of large sockets (hex, Torx, Octatorx, Torx+ I, Torx+ II, and Torx+ III) with screw head diameters of 5.5 mm were manufactured from titanium, and corresponding screwdrivers were manufactured from stainless steel. The screw heads and drivers were mounted on a material testing machine, and torsional tests were conducted to simulate screw usage in clinical settings at two insertion depths: 1 and 2 mm. Ten specimens were tested from each design, and the maximum torque and failure patterns were recorded and compared. For small sockets in 2 mm conditions, the hex with the largest driver core had the highest torque, followed by Torx and cruciate. In these tests, the drivers were twisted off in all specimens. However, under the 1 mm condition, the hex slipped and the torque decreased markedly. Overall, torque was higher for large sockets than for small sockets. The Octatorx, with a large core and simultaneous deformation of the driver and socket lobes, had the highest torque at almost twice that of the small hex. The hex had the lowest torque, a result of slippage in both the 1 and 2 mm conditions. Torx plus designs, with more designed degrees of freedom, were able to maintain a higher driving angle and larger core for higher torque. The hex design showed slipping tendencies with a marked decrease in torque, especially under conditions with inadequate driver engagement. Large sockets allowed for substantial increases in torque. The Torx, Octatorx, and Torx plus designs displayed better performance than the hexes. Improvements to the socket design could effectively prevent slippage and solve difficult screw removal problems. Copyright © 2018. Published by Elsevier Ltd.
Aziz, Mina Sr; Tsuji, Matthew Rs; Nicayenzi, Bruce; Crookshank, Meghan C; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan
2014-05-01
During orthopedic surgery, screws are inserted by "subjective feel" in humeri for fracture fixation, that is, stopping torque, while trying to prevent accidental over-tightening that causes screw-bone interface failure, that is, stripping torque. However, no studies exist on stopping torque, stripping torque, or stopping/stripping torque ratio in human or artificial humeri. This study evaluated five types of humeri, namely, human fresh-frozen (n = 19), human embalmed (n = 18), human dried (n = 15), artificial "normal" (n = 13), and artificial "osteoporotic" (n = 13). An orthopedic surgeon used a torque screwdriver to insert 3.5-mm-diameter cortical screws into humeral shafts and 6.5-mm-diameter cancellous screws into humeral heads by "subjective feel" to obtain stopping and stripping torques. The five outcome measures were raw and normalized stopping torque, raw and normalized stripping torque, and stopping/stripping torque ratio. Normalization was done as raw torque/screw-bone interface area. For "gold standard" fresh-frozen humeri, cortical screw tests yielded averages of 1312 N mm (raw stopping torque), 30.4 N/mm (normalized stopping torque), 1721 N mm (raw stripping torque), 39.0 N/mm (normalized stripping torque), and 82% (stopping/stripping torque ratio). Similarly, fresh-frozen humeri gave cancellous screw average results of 307 N mm (raw stopping torque), 0.9 N/mm (normalized stopping torque), 392 N mm (raw stripping torque), 1.2 N/mm (normalized stripping torque), and 79% (stopping/stripping torque ratio). Of the five cortical screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in four cases (embalmed), three cases (dried), four cases (artificial "normal"), and four cases (artificial "osteoporotic"). Of the five cancellous screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in five cases (embalmed), one case (dried), one case (artificial "normal"), and zero cases (artificial "osteoporotic"). Stopping/stripping torque ratios were relatively constant for all groups at 77%-88% (cortical screws) and 79%-92% (cancellous screws). © IMechE 2014.
NASA Astrophysics Data System (ADS)
Chi, Sheng; Lee, Shu-Sheng; Huang, Jen, Jen-Yu; Lai, Ti-Yu; Jan, Chia-Ming; Hu, Po-Chi
2016-04-01
As the progress of optical technologies, different commercial 3D surface contour scanners are on the market nowadays. Most of them are used for reconstructing the surface profile of mold or mechanical objects which are larger than 50 mm×50 mm× 50 mm, and the scanning system size is about 300 mm×300 mm×100 mm. There are seldom optical systems commercialized for surface profile fast scanning for small object size less than 10 mm×10 mm×10 mm. Therefore, a miniature optical system has been designed and developed in this research work for this purpose. Since the most used scanning method of such system is line scan technology, we have developed pseudo-phase shifting digital projection technology by adopting projecting fringes and phase reconstruction method. A projector was used to project a digital fringe patterns on the object, and the fringes intensity images of the reference plane and of the sample object were recorded by a CMOS camera. The phase difference between the plane and object can be calculated from the fringes images, and the surface profile of the object was reconstructed by using the phase differences. The traditional phase shifting method was accomplished by using PZT actuator or precisely controlled motor to adjust the light source or grating and this is one of the limitations for high speed scanning. Compared with the traditional optical setup, we utilized a micro projector to project the digital fringe patterns on the sample. This diminished the phase shifting processing time and the controlled phase differences between the shifted phases become more precise. Besides, the optical path design based on a portable device scanning system was used to minimize the size and reduce the number of the system components. A screwdriver section about 7mm×5mm×5mm has been scanned and its surface profile was successfully restored. The experimental results showed that the measurement area of our system can be smaller than 10mm×10mm, the precision reached to +/-10μm, and the scanning time for each surface of an object was less than 15 seconds. This has proved that our system own the potential to be a fast scanning scanner for small object surface profile scanning.
NASA Astrophysics Data System (ADS)
Scopelitis, Stephanie A.
As human beings, we live in, live with, and live through our bodies. And because of this it is no wonder that our hands and bodies are in motion as we interact with others in our world. Hands and body move as we give directions to another, anticipate which way to turn the screwdriver, and direct our friend to come sit next to us. Gestures, indeed, fill our everyday lives. The purpose of this study is to investigate the functional role of the body in the parts of our lives where we teach and learn with another. This project is an investigation into, what I call, "interactive explanations". I explore how the hands and body work toward the joint achievement of explanation and learning in face-to-face arrangements. The study aims to uncover how the body participates in teaching and learning in and across events as it slides between the multiple, interdependent roles of (1) a communicative entity, (2) a tool for thinking, and (3) a resource to shape interaction. Understanding gestures functional roles as flexible and diverse better explains how the body participates in teaching and learning interactions. The study further aims to show that these roles and functions are dynamic and changeable based on the interests, goals and contingencies of participants' changing roles and aims in interactions, and within and across events. I employed the methodology of comparative microanalysis of pairs of videotaped conversations in which, first, experts in STEM fields (Science, Technology, Engineering and Mathematics) explained concepts to non-experts, and second, these non-experts re-explained the concept to other non-experts. The principle finding is that people strategically, creatively and collaboratively employ the hands and body as vital and flexible resources for the joint achievement of explanation and understanding. Findings further show that gestures used to explain complex STEM concepts travel across time with the non-expert into re-explanations of the concept. My analysis demonstrates that gestures and the body are complex, multi-functional resources that work toward cognitive, communicative, and interactional achievement and, as such, are viable resources for teaching and learning in face-to-face interaction.
Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W
2010-01-01
Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α = .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20) = 48.87, P = .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20) = 16.25, P = .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20) = 43.20, P = .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.
Tsuji, Matthew; Crookshank, Meghan; Olsen, Michael; Schemitsch, Emil H; Zdero, Rad
2013-06-01
Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental over-tightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/ stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2N/mm (cortical screws) and 13.4N/mm (cancellous screws) in sawbone blocks and 20.9N/mm (cortical screws) and 6.1N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4N/mm (cortical screws) and 16.8N/mm (cancellous screws) in sawbone blocks and 29.3N/mm (cortical screws) and 8.3N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the effect of sawbone density or human bone sBMD on stopping and stripping torque. Copyright © 2013 Elsevier Ltd. All rights reserved.
Swartz, Erik E; Decoster, Laura C; Norkus, Susan A; Cappaert, Thomas A
2007-01-01
Context: Most research on face mask removal has been performed on unused equipment. Objective: To identify and compare factors that influence the condition of helmet components and their relationship to face mask removal. Design: A cross-sectional, retrospective study. Setting: Five athletic equipment reconditioning/recertification facilities. Participants: 2584 helmets from 46 high school football teams representing 5 geographic regions. Intervention(s): Helmet characteristics (brand, model, hardware components) were recorded. Helmets were mounted and face mask removal was attempted using a cordless screwdriver. The 2004 season profiles and weather histories were obtained for each high school. Main Outcome Measure(s): Success and failure (including reason) for removal of 4 screws from the face mask were noted. Failure rates among regions, teams, reconditioning year, and screw color (type) were compared. Weather histories were compared. We conducted a discriminant analysis to determine if weather variables, region, helmet brand and model, reconditioning year, and screw color could predict successful face mask removal. Metallurgic analysis of screw samples was performed. Results: All screws were successfully removed from 2165 (84%) helmets. At least 1 screw could not be removed from 419 (16%) helmets. Significant differences were found for mean screw failure per helmet among the 5 regions, with the Midwest having the lowest failure rate (0.08 ± 0.38) and the Southern (0.33 ± 0.72), the highest. Differences were found in screw failure rates among the 46 teams (F1,45 = 9.4, P < .01). Helmets with the longest interval since last reconditioning (3 years) had the highest failure rate, 0.47 ± 0.93. Differences in success rates were found among 4 screw types (χ21,4 = 647, P < .01), with silver screws having the lowest percentage of failures (3.4%). A discriminant analysis (Λ = .932, χ214,n=2584 = 175.34, P < .001) revealed screw type to be the strongest predictor of successful removal. Conclusions: Helmets with stainless steel or nickel-plated carbon steel screws reconditioned in the previous year had the most favorable combination of factors for successful screw removal. T-nut spinning at the side screw locations was the most common reason and location for failure. PMID:17597938
Magdalon, Eliane C; Michaelsen, Stella M; Quevedo, Antonio A; Levin, Mindy F
2011-09-01
Virtual reality (VR) technology is being used with increasing frequency as a training medium for motor rehabilitation. However, before addressing training effectiveness in virtual environments (VEs), it is necessary to identify if movements made in such environments are kinematically similar to those made in physical environments (PEs) and the effect of provision of haptic feedback on these movement patterns. These questions are important since reach-to-grasp movements may be inaccurate when visual or haptic feedback is altered or absent. Our goal was to compare kinematics of reaching and grasping movements to three objects performed in an immersive three-dimensional (3D) VE with haptic feedback (cyberglove/grasp system) viewed through a head-mounted display to those made in an equivalent physical environment (PE). We also compared movements in PE made with and without wearing the cyberglove/grasp haptic feedback system. Ten healthy subjects (8 women, 62.1±8.8years) reached and grasped objects requiring 3 different grasp types (can, diameter 65.6mm, cylindrical grasp; screwdriver, diameter 31.6mm, power grasp; pen, diameter 7.5mm, precision grasp) in PE and visually similar virtual objects in VE. Temporal and spatial arm and trunk kinematics were analyzed. Movements were slower and grip apertures were wider when wearing the glove in both the PE and the VE compared to movements made in the PE without the glove. When wearing the glove, subjects used similar reaching trajectories in both environments, preserved the coordination between reaching and grasping and scaled grip aperture to object size for the larger object (cylindrical grasp). However, in VE compared to PE, movements were slower and had longer deceleration times, elbow extension was greater when reaching to the smallest object and apertures were wider for the power and precision grip tasks. Overall, the differences in spatial and temporal kinematics of movements between environments were greater than those due only to wearing the cyberglove/grasp system. Differences in movement kinematics due to the viewing environment were likely due to a lack of prior experience with the virtual environment, an uncertainty of object location and the restricted field-of-view when wearing the head-mounted display. The results can be used to inform the design and disposition of objects within 3D VEs for the study of the control of prehension and for upper limb rehabilitation. Copyright © 2011 Elsevier B.V. All rights reserved.
Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.
2010-01-01
Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α = .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20 = 48.87, P = .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20 = 16.25, P = .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20 = 43.20, P = .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179
Alternative Energy Lessons in Scotland
NASA Astrophysics Data System (ADS)
Boyle, Julie
2010-05-01
In Scotland the new science curriculum for pupils aged 12 to 15 shall include the following outcomes: "Using my knowledge and understanding, I can express an informed view on a national or global environmental issue;" "I have participated in constructing a model to harness a renewable source of energy and can investigate how to optimise the output;" and "I can discuss why it is important to me and to the future of the world that alternatives to fossil fuels are developed." There will be an emphasis on creating lessons that will nurture responsible citizens, improve pupil engagement and allow students to develop their team working skills. To help teachers plan lessons to address this, the Scottish Schools Equipment Research Centre and Edinburgh University made teaching materials on four renewable energy resources. This poster describes how their suggested activities on solar cells, wind turbines, hydroelectric power stations and wave power were used in science lessons with twelve year old students. After an initial class discussion based on issues related to climate change and diminishing fossil fuel supplies, a workshop activity was carried out in three stages. The students were issued with a fact sheet about one of four imaginary islands (Skisdale, Cloudy Island, Surfsville and Sun City) and they were asked to work in teams to choose the most suitable method of generating electricity for their island. Issues such as costs, where it will be sited and environmental implications were considered. They were then asked to conduct practical activities by constructing and testing models for these forms of renewable energy. To conclude, they presented their proposal to the rest of the class with reasoned explanations. The kits used in the lessons can be purchased from Anderson Scientific (sales@andersonscientific.co.uk). The solar cells were simply connected to a voltmeter. The wind and hydroelectric groups used the same basic equipment. This was made using a small water bottle, insulating tape, a screwdriver, a connecting block, a solar motor, a plastic fan and thin wires. The only difference was that the wind groups were issued hairdryers and the hydroelectric groups worked at a sink. The wave turbine was constructed in a similar way using the bases from two 5 litre water bottles. Various investigations were conducted into the factors affecting the voltage produced. For instance, the effect of the distance from the light source, the area of the solar cell, the type of blades, the depth of water and the wind speed were studied. The lessons reinforced their understanding of ideas covered in Science and Geography, such as voltage, power, fair tests, compass directions and map contours. Students also had the opportunity to practise connecting electrical components in series and they consolidated their understanding of energy changes, observing that generators convert kinetic energy to electrical energy. The activities allowed students to learn the basics of how renewable energy technologies work. The tasks provided a hands-on experience of renewable energy being used to power small-scale electrical devices such as an LED. The students also gained an appreciation of the complex issues involved in planning and implementing renewable energy generation in the real world.
Forensic evidence in apparel fabrics due to stab events.
Kemp, S E; Carr, D J; Kieser, J; Niven, B E; Taylor, M C
2009-10-30
Stab injuries and fatalities have been reported to be the most common crimes of violence in several countries, particularly in those where access to firearms is restricted [J.M. Taupin, F.-P. Adolf, J. Robertson, Examination of damage to textiles, in: J. Robertson, M. Grieve (Eds.), Forensic Examination of Fibres, CRC Press, United States of America, 1999, pp. 65-87; A.C. Hunt, R.J. Cowling, Murder by stabbing, Forensic Sci. Int. 52 (1991) 107-112; D.A. Rouse, Patterns of stab wounds: a six year study, Med. Sci. Law 34 (1994) 67-71]. Analysis of damaged apparel may provide important information about the cause of death and the events leading up to and after the victim's final moments [M.T. Pailthorpe, N.A.G. Johnson, The private forensic scientist and the criminal justice system, in: D. Biles, J. Vernon (Eds.), Private Sector and Community Involvement in the Criminal Justice System: Conference Proceedings, vol. 23, Australian Institute of Criminology, Wellington, 1994, 231-240]. A high proportion of stab wounds occur in the chest and as this area is generally clothed many sharp force cases involve damage to fabrics [J.M. Taupin, F.-P. Adolf, J. Robertson, Examination of damage to textiles, in: J. Robertson, M. Grieve (Eds.), Forensic Examination of Fibres, CRC Press, United States of America, 1999, pp. 65-87; A.C. Hunt, R.J. Cowling, Murder by stabbing, Forensic Sci. Int. 52 (1991) 107-112; D.A. Rouse, Patterns of stab wounds: a six year study, Med. Sci. Law 34 (1994) 67-71]. The structural stabilisation and degradation of fabric due to laundering significantly alters fabric properties [S.E. Gore, R.M. Laing, C.A. Wilson, D.J. Carr, B.E. Niven, Standardizing a pre-treatment cleaning procedure and effects of application on apparel fabrics, Text. Res. J. 76 (2006) 455-464], yet the effect of such on severance morphology does not appear to have been investigated. In this work the effect of blade type (hunting knife, kitchen knife, screwdriver) on new and laundered apparel fabrics was investigated. Two approaches were used (i) a human participant trial, and (ii) guided drop testing (using an impact rig). Force-time plots from the human participant trials were matched to those from the impact rig. Information on severance morphology was obtained using visual analysis techniques. Blades could be differentiated and directionality estimated by observing differences in severance shape and size, the degree of fabric distortion, the position of severed yarn ends, loop snippets, curled yarns, planar array and the morphology of fractured fibres. Fabric construction had a visible effect on severance morphology. Pre-impact degradation via laundering hindered the ability to link fractured fibre ends to a source of damage by altering morphology and increasing the variability. The correlation between blade height and severance length was weak, attributed to elastic deformation and recovery. The impact rig was a valuable tool in the reconstruction of textile damage. Damage was consistent when inflicted using a human participant trial and the impact rig, although more variable in the former. The advantage of the impact rig lies in the ability to produce a severance typical of the blade in question, under controlled conditions, in a reproducible manner.
Advanced Methods for Aircraft Engine Thrust and Noise Benefits: Nozzle-Inlet Flow Analysis
NASA Technical Reports Server (NTRS)
Gilinsky, Mikhail; Morgan, Morris H.; Hardin, Jay C.; Mosiane, Lotlamoreng; Kaushal, Patel; Blankson, Isaiah M.
2000-01-01
In this project, we continue to develop the previous joint research between the Fluid Mechanics and Acoustics Laboratory (FM&AL) at Hampton University (HU) and the Jet Noise Team (JNT) at the NASA Langley Research Center (NASA LaRC). The FM&AL was established at Hampton University in June of 1996 and has conducted research under two NASA grants: NAG-1-1835 (1996-99), and NAG-1-1936 (1997-00). In addition, the FM&AL has jointly conducted research with the Central AeroHydrodynamics Institute (TsAGI, Moscow) in Russia under a Civilian Research and Development Foundation (CRDF) grant #RE2-136 (1996-99). The goals of the FM&AL programs are twofold: (1) to improve the working efficiency of the FM&AUs team in generating new innovative ideas and in conducting research in the field of fluid dynamics and acoustics, basically for improvement of supersonic and subsonic aircraft engines, and (2) to attract promising minority students to this research and training and, in cooperation with other HU departments, to teach them basic knowledge in Aerodynamics, Gas Dynamics, and Theoretical and Experimental Methods in Aeroacoustics and Computational Fluid Dynamics (CFD). The research at the HU FM&AL supports reduction schemes associated with the emission of engine pollutants for commercial aircraft and concepts for reduction of observables for military aircraft. These research endeavors relate to the goals of the NASA Strategic Enterprise in Aeronautics concerning the development of environmentally acceptable aircraft. It is in this precise area, where the US aircraft industry, academia, and Government are in great need of trained professionals and which is a high priority goal of the Minority University Research and Education (MUREP) Program, that the HU FM&AL can make its most important contribution. The main achievements for the reporting period in the development of concepts for noise reduction and improvement in efficiency for jet exhaust nozzles and inlets for aircraft engines are as follows: (1) Publications- The AIAA Paper #99-1924 has been presented at the 5th AIAA/CEAS Aeroacoustics Conference, May 10-12, 1999, Seattle, WA; the AIAA Paper #00-3315 has been accepted for the 36th AIAA/ASME/ SAE/ASEE Joint Propulsion Conference, 17-19 July, 2000, Huntsville, AL; and another paper has been accepted for the International Environmental Congress, 14-16 June, 2000, St.-Petersburg, Russia. (2) Two patents were granted on July 20, 1999, and January 12, 2000. (3) Three reports/presentations at the NASA LaRC and GRC (06/22199, 09/26/ 99, and 06/25/00). (4) Grants and Proposals: Four proposals were submitted to the NASA and CRDF; a NASA Faculty Award was granted on January, 2000. A CRDF Young Investigator Program Award was granted for a 3 months visit of the Russian scientist to the HU FM&AL (03/99-05/99). (5) Theory and Numerical Simulations- Analytical theory, numerical simulation, comparison of theoretical with experimental results, and modification of theoretical approaches, models, grids etc. have been conducted for several complicated 2D and 3D nozzle and inlet designs using NASA codes based on full Euler and Navier-Stokes solvers: CFL3D, CRAFT, GODUNOV, and others. New approach for environmental monitoring via infrasound. (6) Experimental Tests: Experimental acoustic tests at the TsAGI, Moscow, with nozzles having Screwdriver or Axisymmetric Plug and Permeable Shells. A small scale working model of the NASA Low Speed Wind Tunnel (LSWT) has been installed in the Experimental Hall of the HU FM&AL (June, 1999). Preliminary preparations for experimental tests were made. (7) Students Research Activity: Involvement of the two graduate students as research assistants in the current research project.
Variability of the cranial and dental phenotype in Williams syndrome.
Axelsson, Stefan
2005-01-01
Williams syndrome (WS) is a rare congenital disorder involving the cardiovascular system, connective tissue, and the central nervous system, resulting in mild to moderate mental retardation, a specific cognitive profile, unique personality characteristics, distinctive facial features, and cardiovascular disease. The majority of individuals with a clinical diagnosis of WS have a contiguous gene deletion at chromosome 7 (7q11.23). Physical features include characteristic facial features with full prominent cheeks, wide mouth, long philtrum, small nose with depressed nasal bridge, heavy orbital ridges, medial eyebrow flare, dental abnormalities, hoarse voice, growth retardation, and cardiovascular abnormalities (most commonly supravalvular aortic stenosis and/or peripheral pulmonary artery stenosis). The cognitive profile is distinctive, consisting of strengths in auditory memory, language, and face-processing, but extreme weakness in visuospatial, numerical and problem-solving abilities. Neurological studies have identified a significantly decreased brain volume in adult individuals with WS with relatively normal development of the limbic, frontal and cerebellar structures. The aims were to analyse the neurocranium, the craniofacial region, and the dentition in a well defined Norwegian group of individuals with WS. In order to accomplish this, normative cephalometric standards for the neurocranium, including the cranial base and the sella turcica, were established for Norwegian males and females from 6 to 21 years of age, using lateral radiographic cephalograms from the Oslo University Craniofacial Growth Archive. The study material comprised radiographic lateral cephalograms, orthopantomograms and dental casts from 62 individuals with WS ranging from 4 to 44 years. The lateral cephalograms, orthopantomograms and dental casts were analysed using standard methods reported in the literature. Neurocranium: The results from the cephalometric analyses showed that the size and shape of the neurocranium in WS differed from normal controls. A flattening of the superior aspect of the parietal bone was found and the posterior prominence of the occipital bone was larger. These findings were in concordance with published neuroanatomical/neuropathological studies on WS and fit well with the reported anatomical aberrations in the WS brain, e.g. a smaller brain volume where some parts are of relatively normal size while others are decreased. The anterior and posterior cranial base was shorter in WS, but with a normal cranial base angle. The thickness of the calvarian bones, especially the frontal and occipital bones, was greater in WS than in normal controls. Sella turcica: The size of the sella turcica was somewhat smaller in WS compared with normal controls, though not significant. Aberrant types of shape of the sella turcica in WS are demonstrated. The correlation between prenatal malformation in the pituitary gland/sella turcica and the postnatal morphology of the sella turcica is discussed. The craniofacial skeleton: Two areas, in addition to the cranial base, have been identified to contribute to the characteristic facial appearance in WS; the anterior inclination of the maxilla, and the shape of the mandible. The severely deficient bony chin in combination with the high mandibular plane angle can explain earlier clinical descriptions of a retrusive mandible in WS. Frequent mouth breathing during childhood and the smaller cranial base may be associated with the characteristic craniofacial pattern. Dentition: In individuals with WS over 10 years of age 40.5 per cent had agenesis of one or more permanent teeth and 11.9 percent had agenesis of 6 teeth or more. The missing permanent teeth in the maxilla most commonly included 2nd premolars, 1st premolars, and lateral incisors. In the mandible most commonly 2nd premolars, 1st premolars, and central incisors were absent. The tooth crowns of permanent teeth were smaller, both in the mesio-distal and labio-lingual dimension. The permanent tooth crowns have several characteristic deviations from normal shape; especially incisors in both jaws were tapered or screwdriver-shaped. An evaluation of taurodontism on permanent molars was performed. However, most of the molars rated as being taurodontic had short total tooth lengths and could thus be rated taurodontic without meeting the classical definition. These studies have shown aberrations in the neurocranium including the sella turcica in WS not previously reported. In the craniofacial skeleton specific traits have been identified to contribute to the characteristic facial appearance in WS. Dental aberrations in the permanent dentition including agenesis, smaller size, and aberrant shape of teeth, are common in WS.